Drainvac Atomik Owner's Manual
Drainvac Atomik is a central vacuum cleaner with a 30 ft. hose and 3 utility tools, designed for residential use. It features a 14” height and 7” diameter, with a capacity of 0.39 gal. imp. / 1.5 L and a weight of 11 lb / 5 kg. The unit operates at 108 - 120 voltage and produces 600 AIRWATTS, 100 H20, 154 CFM, and 69 dB at 10’ / 69 dB at 3 m.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Central Vacuums
OWNER’S MANUAL
ATOMIK
*** OPEN THE UNIT’S LID BEFORE USING ***
IMPORTANT SAFETY INSTRUCTIONS
Important safety measures the use of an electrical appliance, certain precautions most be followed, including the following. Read all instructions before using the Atomik.
To reduce the risk of fire, electric shock or injury:
• Disconnect all electrical sources located on the wall where the unit will be installed.
• Do not leave the appliance unattended when plugged. Unplug when not used, before maintenance and before the installation is complete.
• Turn off all controls before unplugging.
• Do not use the appliance if the plug or power cord is damaged.
• Return the unit to the distributor if its does not operate normally, has been dropped, damaged or was left outdoors.
• The cord should not be used as a handle or to pull or lift the unit. Do not put the unit on the cord, do not pinch the cord in the doorway while closing a door or pull on a corner of a wall or other sharp edges and keep it away from hot surfaces.
• Do not pull the cord to unplug the device, rather pull the plug.
• Do not touch the plug or appliance with wet hands.
• Do not modify the device or its parts.
• The installation of the device must be vertical.
• Do not use outdoors or near source of excess moisture. Never vacuum liquid, fuels or imflammables materials with your device.
Do not use it in a place where there are such substances.
• Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
• Use the product according to the guidelines in this instruction manual and use only the accessories recommended by the manufacturer.
• Do not let children play or use it without adult supervision. Extra care must be taken if children are close when using the device.
• Do not insert objects into any opening of the unit. Do not use if an opening is blocked and remove dust, lint, hair, etc.., which may impede the airflow.
• Be sure to keep fingers, hair, loose clothing away from openings and moving parts.
• Use extra caution when cleaning stairs.
3
Instruction for grounding
This appliance must be grounded. In case of failure or breakdown, the circuit grounding provides a path of least resistance which reduces the risk of electric shock. The device comes with a cord equipped with a lead which insures grounding and a ground pin. The plug must be plugged into an outlet that is properly installed and grounded in accordance with applicable local codes and regulations. Warning: a ground wire connected incorrectly presents risk of electric shock. Consult an electrician or a qualified service technician in doubt about the grounding. Do not modify the plug thats comes with the device, if it does not fit into the outlet, install a new outlet by a qualified electrician.
Drainvac International 2006 Inc. declines all responsibility if you violate any of these guidelines.
INTRODUCTION
We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A judicious investment you will enjoy for many years. The Drainvac Atomik central vacuum cleaner is built with the best components available on the market. They are manufactured and tested at our plant by a qualified and specially trained staff. However some installation and operation procedures must be followed to insure maximum performance and to avoid needless service calls. Please read the following carefully.
REGISTRATION
You must register your Drainvac Atomik vacuum cleaner on our website to cover your warranty. Scan the QR code with your smartphone or visit our website at www.drainvac.com/ca/en/
client-support/warranty-registration/
TABLE OF CONTENTS
UNIT DESCRIPTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
EQUIPMENT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
UNIT INSTALLATION
FIRST THINGS FIRST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
FILTER INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
MOUNTING THE UNIT ON THE WALL . . . . . . . . . . . . . . . . . . . . . . . 11
CONNECTING THE ACTIVAC 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CONNECTING THE UTILITY INLET . . . . . . . . . . . . . . . . . . . . . . . . 13
INSTALLATION ON PIPING SYSTEM
. . . . 14
ELECTRICAL POWER SUPPLY
. . . . . . . . . . . . . 15
MAINTENANCE PROCEDURES
. . . . . . . . . . . . 16
ACCESSORIES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-18
TECHNICAL PROBLEMS
. . . . . . . . . . . . . . . . . . . . . . 19
WEEE GUIDELINES / SUPPORT
. . . . . . . . . . 20
SAVE THESE INSTRUCTIONS
UNIT DESCRIPTION
1
1. Clamps
2. Entry
3. Exhaust
4. 24V connection
5. Power switch
6. Breaker / Fuse
7. Green LED
1
2
4 5
6
7
AIRWATTS
H
2
0
CFM
DECIBEL
VOLTAGE
HEIGHT
DIAMETER
CAPACITY
WEIGHT
600
100
154
69 dB at 10’ / 69 dB à 3 m
108 - 120
14” / 35 cm
7” / 18 cm
0.39 gal. imp. / 1.5 L
11 lb / 5 kg
*The carbon brushes are irreplaceable.
6
3
EQUIPMENT
The Atomik includes a 30 ft. (9 m) hose with 3 utility tools, chrome metal hanger, black plastic telescopic wand, black plastic hanger for accessories and 12 in (30 cm) floor brush without wheels.
1
2
3
4
5
9
7
8
6
1. Dust bag
2. Polyester filter
3. Collars
4. Utility inlet
5. PVC coupling
6. Medium 90 o elbow
7. 12’’ (30 cm) 24V wires with connectors
8. #1 screws
9. Activac 1 exhaust filter
7
UNIT INSTALLATION
- FIRST THINGS FIRST -
Pliers Cutters
UNIT INSTALLATION
- FIRST THINGS FIRST -
DIMENSIONS & MINIMUM SPACING
Front view
Min. 12’’ (30.5 cm)
Min. 12’’ (30.5 cm)
Min. 19’’
(22.75 cm)
Phillips screwdriver (star) Flat screwdriver
Measuring tape 2,25’’ (57 mm) hole saw
0,5’’ (12,5 mm) hand drill
Side view
Min. 1’’ (2.5 cm)
Min. 18’’ (45.75 cm)
8
Mitre box & saw or Pipe cutter
9
UNIT INSTALLATION
1) FILTER INSTALLATION
• Detach the clamps, remove the lid and take off the plastic bag.(The plastic bag included equipment for the installation of the unit. Keep it near the unit).
UNIT INSTALLATION
2) MOUNTING THE UNIT ON THE WALL
• Remove the wall plate that is attached to the back of the unit using a pair of cutters.
• Make sure the polyester filter and dust bag are properly installed.
• Install the wall plate to the wall using the 4 x #1 screws included with the unit.
#1 (1,25’’ - 30 mm)
• Close back the lid and attach the clamps.
10
• Lift the unit and mount the top part (A) of the unit bracket behind the top part of the wall plate. At the same time, install the bottom part (B) of the unit bracket inside of the bottom part of the wall plate.
A
B
11
UNIT INSTALLATION
CONNECTING THE ACTIVAC 1
Activac 1 exhaust filter
Collar
Medium 90 o elbow
Collar
UNIT INSTALLATION
4) CONNECTING THE UTILITY INLET
2 collars
Utility inlet
PVC coupling
12’’ (30 cm) 24V wire with connectors
12 13
INSTALLATION ON PIPING SYSTEM
In a condo, in a garage, in a RV, in the mecanic room, etc.
ELECTRICAL POWER SUPPLY
The Drainvac Atomik vacuum cleaner is equipped with an electrical cord.
An adequate electrical power outlet must be installed close to the unit.
We strongly recommend installing an electrical circuit that will be used only by the unit.
North American model: ATOMIK6-30 require an 15 amps/108V - 120V circuit.
International model: ATOMIK60-30 require an 16 amps/220V - 240V circuit.
Also plan the 24 volt between the unit, the piping system and the inlets.
14
24V wires
Power outlet
Type B
Type E Type G
Type I
Nema 6-15 (220V)
15
MAINTENANCE PROCEDURES
All mechanical systems require a minimum of maintenance, your system is not an exception. Beyond the occasional external cleaning, you must:
• replace or clean the polyester filter periodically,
• replace or empty the the dust bag periodically, otherwise the suction power will greatly decrease. Moreover, this maintenance will assure a optimal air quality.
1. Unclamp the lid from the unit.
2. Remove and discard the dust bag and the polyester filter.
You can re-use the dust bag a few times all depending on the use (Image A). The misuse of this bag may invalidate the warranty.
3. Install a new dust bag & polyester filter (Image B).
You can install bag if the conditions above are respected.
4. Reattach the lid to the main unit.
Image A
Lid
Dust bag
Polyester filter
Clamps
Main unit
Image B
IF THE UNIT IS USED WITHOUT ITS FILTERS,
THE WARRANTY WILL BE VOIDED.
16
Rotating carpet brush
Installation kit
1, 2 or 3 inlet
ACCESSORIES
Hose cover
17
ACCESSORIES
18
Polyester filter &
3 x dust bags
Activac 1 exhaust filter
Dustpan installation kit
Utility inlet
TECHNICAL PROBLEMS
The unit will not start:
1. Check the circuit breaker on your electrical panel.
2. Check the circuit breaker of the unit. (Image D1)
3. Check the 24 volt circuit:
To check the 24 volt circuit, proceed as follow;
• Establish the contact between the two ports of a wall mounted air inlet valve with a piece of metal (ex. coin (Image E)). If the system starts, the suction hose is defective. See your dealer.
• If the system does not start check the 24 volt wires on the unit
(Image D2); Establish the contact between the two screws of the
24V circuit plate using a piece of metal (ex. Screw driver (Image F)).
If the unit starts, the 24 volt wire is either cut OR unplugged from one of the wall mounted air inlet valves.
• If the system still do not start after steps 1, 2 and 3, the printed circuit is defective. Call your dealer.
The unit will not stop:
Check the 24 volt circuit as follows;
• Disconnect one of the two 24 volt wires on the unit (Image D2). If the unit stops, the two wires are in contact somewhere in the circuit
OR a wall mounted air inlet valve is defective.
• If the unit does not stop, the printed circuit is defective.
Call your dealer.
NOTE: If you notice a vibration coming from the motor, call your dealer.
Image D
Image E
Coin
Breaker / Fuse (1)
24V wires(2)
Image F
19
WEEE GUIDELINES
This unit complies with the WEEE (Waste
Electrical and Electronic Equipment) Guidelines, which promote the recycling of this type of waste equipment and encourage the development of products that are adapted to efficient waste reclamation at the end of their life cycle.
The WEEE Guidelines stipulate that the original supplier should agree to reclaim any obsolete
Image C equipment free of charge. We recommend that you advise your supplier that you would like him to reclaim your unit when you order and replace it with a new one.
Do not discard the unit with your regular garbage. The symbol representing a garbage bin on wheels on the unit’s label (Image C) attests to this requirement. You must ensure that, at the end of its life cycle, your unit is reclaimed, treated and recycled by an authorized firm.
For more information, contact your municipal waste management department.
The acquirer of the Automatik system is commited to respect the environmental regulations of the liquid and solid waste disposal in the public water system.
SUPPORT
If you wish to speak with a customer service representative, please contact your supplier/dealer.
To find a retailer near you, please visit our website : www.drainvac.com/ca/en/retailers/find-a-retailer/
Drainvac International 2006 Inc.
150 Brunet street, Mont-St-Hilaire, Quebec, Canada, J3H 0M6
20
Central Vacuums
advertisement