Lutron Radio Powr Savr LRF2-OCR2B-P-WH Quick

Lutron Radio Powr Savr LRF2-OCR2B-P-WH Quick
Lutron energy-saving products
PowPak® dimming
module (actual size)
Radio Powr Savr TM
occupancy/vacancy
sensor (actual size)
Pico® wireless
control (actual size)
Quick Install Energy Solutions
Featuring Energi TriPak
®
Energi TriPak
®
Energi TriPak is a family of wireless energy-saving products featuring
Radio Powr SavrTM sensors, Pico® controls and PowPak®/Maestro Wireless®
load controllers. These components, when combined:
save up to 60%1 of lighting electricity usage
• increase occupant comfort and productivity
• control virtually all loads
• reduce installation and programming costs
•
Lighting consumes more electricity in commercial
buildings than anything else—about 38%2 a year.
Lutron solutions can save up to 60%1 or more of
that lighting energy.
Annual electricity use2
Lighting
38%
HVAC
29%
Refrigeration
12%
Office Equipment
Other
7%
14%
Lighting typically accounts for 38%2 of electricity usage in new construction and retrofit commercial
applications, which include spaces such as classrooms and offices. These applications benefit from
Energi TriPak energy savings through strategies like automatic occupancy/vacancy sensing and
daylight harvesting.
Studies show that proper lighting is beneficial to space occupants. By providing task-appropriate lighting
and individual lighting control, Energi TriPak improves comfort and occupant satisfaction, resulting in
increased productivity.3
Energi TriPak requires no additional wiring. The components communicate wirelessly via
Lutron’s reliable Clear Connect® Radio Frequency (RF) technology. In addition, simple button
press programming eliminates the need for factory commissioning.
Sources located on back cover.
D | Lutron
Energi TriPak design and application guide
02
What is Energi TriPak?
03
Benefits
04
Energy-saving control strategies
05
Meets codes and standards
Applications
06
Public restroom application
08
Private office application
10
Classroom application
12
How to design a system
Energi TriPak components
14
Radio Powr SavrTM wireless occupancy/vacancy sensors
15
Radio Powr Savr wireless daylight sensor
16
PowPak® relay module
17
PowPak dimming module with EcoSystem®
18
Maestro Wireless® switch
19
Maestro Wireless dimmer
20
Stairwell fixture with PowPak stairwell controller
21
Maestro Wireless tabletop lamp dimmer and
PowPak plug-in dimming module
22
PowPak plug-in appliance module
23
PowPak relay module with Softswitch®
24
PowPak contact closure output module
25
Pico® wireless controls
26
Pico wireless control accessories
How it works
27
Stairwell retrofit solution
28
Variable Air Volume (VAV) integration
29
Plug load control by switching receptacles
Alternate stand-alone solution
30
Maestro® occupancy sensing controls
Sensor coverage diagrams
32
Ceiling-mount, Wall-mount
33
Corner-mount, In-mount
34
Ordering information
Lutron | 1
Energi TriPak
®
What is Energi TriPak?
Energi TriPak consists of transmitting devices that send out RF commands to the load controllers. The load
controllers receive the RF command and perform the appropriate action based on
the information received.
Transmitting devices
Load controllers
Sense
Conserve
Radio Powr SavrTM
wireless sensors
PowPak® load controllers
Occupancy/vacancy
Dimming module
with EcoSystem®
Relay module
Contact closure
output module
Daylight
Plug-in dimming module
Adjust
Plug-in appliance module
Pico® wireless control
Stairwell fixture with PowPak stairwell controller
Maestro Wireless®
Wall-mount
Dimmer
Tabletop
2 | Lutron
Hand-held
Switch
Tabletop lamp
dimmer
Benefits
Easy to install and program
•
All points of control are wireless for simple installation with no new wiring
•
Simple button programming for all devices
Saves energy and money
Simply incorporate the following energy-saving control strategies:
•
Personal dimming control
•
Occupancy/vacancy sensing
•
Daylight harvesting
•
High-end trim
•
Plug load control
•
HVAC integration
Cost-effective
•
No commissioning required
•
Overall labor costs reduced due to wireless communication—no additional wiring
Meets codes and standards
Provides the opportunity to meet the following codes and standards:
•
LEED NC 2009
•
ASHRAE Energy Code 90.1-2010
•
IECC (International Energy Conservation Code)
•
ASHRAE Green Standard 189.1-2011
•
IgCC (International Green Construction Code)
•
CEC Title 24 (California Energy Commission)
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron ® Clear Connect ®
Wireless Signal Received
Lutron | 3
Energi TriPak
®
Energy-saving control strategies
Personal dimming control
Full On
Dim
Gives occupants the ability to
set the light levels.
Occupancy/vacancy sensing
Occupied: On
Vacant: Off
Turns lights on when occupants
are in a space and dims lights to
a low level or turns lights off when
they vacate the space.
Daylight harvesting
Full On
Dim
80%
Max: 100%
Max: 80%
Dims electric light when daylight
is available to light the space.
High-end trim
Sets the maximum light level
based on customer requirements
in each space.
Plug load control
Appliance On Appliance Off
Automatically turns off
loads after occupants leave
a space.
HVAC integration
Heating
Cooling
Controls heating, ventilation,
and air conditioning systems
through contact closure.
Sources located on back cover.
4 | Lutron
Potential lighting
energy savings:
Potential lighting
energy savings:
Potential lighting
energy savings:
Potential lighting
energy savings:
4
10-20%
5
20-60%
6
25-60%
10-30%
Potential controlled
loads savings:
Potential HVAC
savings:
7
8
15-50%
9
5-15%
Meets codes and standards
LEED NC 2009
Can contribute to:
•
SS Credit 8 Light Pollution Reduction (1 point)
•
EA Prerequisite 2 Minimum Energy Performance
•
EA Credit 1 Optimize Energy Performance (up to 19 points)
•
IEQ Controllability of Systems: Lighting (1 point)
•
IEQ Daylight and Views: Daylight (1 point)
•
Innovation in Design (up to 5 points)
•
RP Credit 1 Regional Priority (up to 4 points)
ASHRAE Energy Code 90.1-2010
•
Automatic Receptacle Control (8.4.2)
•
Automatic Lighting Shut-off (9.4.1.1)
•
Space Control (9.4.1.2)
•
Automatic Daylight Controls (9.4.1.4 and 9.4.1.5)
•
Additional Controls, Stairwell Lighting (9.4.1.6 g)
IECC 2012 (International Energy Conservation Code)
•
Interior Lighting Controls (C405.2.1.1)
•
Light Reduction Controls (C405.2.1.2)
•
Occupancy Sensors (C405.2.2.2)
•
Automatic Daylighting (C405.2.2.3.2)
•
Multi-level Lighting Controls (C405.2.2.3.3)
ASHRAE Green Standard 189.1-2011
•
Occupancy Sensor Controls with Multi-level Switching or Dimming (7.4.6.2)
•
Occupancy Sensors (7.4.6.4)
IgCC Public Version 2 (International Green Construction Code)
•
Interior Light Reduction Controls (609.3)
•
Automatic Daylight Controls (609.5)
•
Plug-load Controls (609.6)
CEC Title 24 2008 (California Energy Commission)
•
Area Controls (131 a)
•
Multi-level Lighting Controls (131 b)
•
Daylight Areas (131 c)
•
Shut-off Controls (131 d)
Lutron | 5
Energi TriPak application: Public restroom
®
In public spaces, such as bathrooms,
lighting is often on even when the space
is unoccupied. Automatic lighting control
with occupancy sensing is an ideal energysaving lighting solution.
Energy-saving strategies
Occupancy sensing
Potential lighting
energy savings:
50%
5
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron ® Clear Connect ®
Wireless Signal Received
6 | Lutron
Radio Powr SavrTM
ceiling-mount
occupancy/vacancy
sensor
communicates with
load controllers to
turn lights on or off
PowPak® relay module with Softswitch®
switches loads in response to wireless
sensors and controls (mounted in ceiling)
Lutron | 7
Energi TriPak application: Private office
®
Providing personal lighting control in a
private office application helps improve
occupant comfort.
Energy-saving strategies
Radio Powr SavrTM
daylight sensor
communicates with load
controllers to turn lights
on or off based on amount
of daylight available
Occupancy/vacancy sensing
Daylight harvesting
Plug load control
Potential lighting
energy savings:
45%
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron ® Clear Connect ®
Wireless Signal Received
8 | Lutron
PowPak® plug-in
appliance module
turns phantom loads
on or off in response
to wireless sensors
and controls (located
under desk)
Radio Powr Savr
ceiling-mount
occupancy/vacancy
sensor
communicates with
load controllers to
turn lights on or off
based on occupancy
Pico® wireless control
allows manual control of
loads; place on desk top
or mount to wall
Maestro Wireless®
switch
provides manual control
and switches lighting loads
in response to wireless
sensors and controls
Maestro Wireless
tabletop lamp
dimmer
provides manual control
and dims table lamps
in response to wireless
sensors and controls
Lutron | 9
Energi TriPak application: Classroom
®
A best-practice classroom combines
energy efficiency with a high-quality
learning environment. Classroom lighting
plays a particularly critical role because
of the direct relationship between good
lighting and student performance.10
PowPak® dimming module
with EcoSystem®
dims lighting loads in
response to wireless
sensors and controls
(mounted in ceiling)
Energy-saving strategies
Personal dimming control
Occupancy/vacancy sensing
Daylight harvesting
High-end trim
HVAC integration
Potential lighting
energy savings:
60%
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron ® Clear Connect ®
Wireless Signal Received
10 | Lutron
Pico® wireless
controls
allows manual
control of loads;
place on desk top
or mount to wall
EcoSystem H-Series digital ballast
combines superior 1% dimming performance
and Lutron reliability
PowPak contact closure
output module
integrates with HVAC system
or other third-party equipment
through contact closures,
allowing the equipment to
respond to wireless commands
(mounted in ceiling)
Radio Powr SavrTM
daylight sensor
communicates with load
controllers to dim lights
based on amount
of daylight available
Radio Powr Savr
corner-mount occupancy/
vacancy sensor
communicates with load
controllers to turn lights on
or off based on occupancy
Lutron | 11
How to design a system
Define your space
Use the following steps to plan and design an ideal energy-saving solution
based on the use of the space and the needs of its occupants.
Step 1
Is occupancy/vacancy sensing required?
Select the style of the Radio Powr SavrTM occupancy/vacancy
sensor based on mounting and coverage requirements . . . . . . . . . . . . . . pg. 14
Step 2
Is daylight harvesting required?
Select the Radio Powr Savr daylight sensor . . . . . . . . . . . . . . . . . . . . . . . pg. 15
Step 3
Is control of overhead lighting required?
a. Select the control(s) required based on style and load capacity . . . pgs. 16-19
b. Select the stairwell fixture with PowPak stairwell controller for
stairwell applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 20
Step 4
Is control of task lighting required?
Select the style of plug-in device required . . . . . . . . . . . . . . . . . . . . . . . . pg. 21
12 | Lutron
Step 5
Is control of plug loads required?
Select the style of plug load controller required . . . . . . . . . . . . . . . . . . . .pg. 22
Step 6
Is third-party equipment integration required?
Select the PowPak contact closure output module . . . . . . . . . . . . . . . . . pg. 24
Step 7
Are personal or additional points of control required?
a. Select the style of the Pico® wireless control required . . . . . . . . . . . . . .pg. 25
b. Select accessories for Pico wireless control . . . . . . . . . . . . . . . . . . . . .pg. 26
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron ® Clear Connect ®
Wireless Signal Received
Lutron | 13
Energi TriPak components
®
Step 1 Occupancy/vacancy sensor selection
Radio Powr Savr wireless occupancy/vacancy sensors
TM
Design statement: Specify a wireless occupancy/vacancy or vacancy-only sensor to turn lights
on and/or off based on the space occupancy.
•
•
•
Radio Powr Savr wireless
ceiling-mount occupancy/
vacancy sensor dimensions
W: 3.57" (91 mm)
H: 3.57" (91 mm)
D: 1.13" (29 mm)
•
•
•
•
•
Radio Powr Savr wireless
wall/hall/corner-mount
occupancy/vacancy
sensor dimensions
W: 1.8" (46 mm)
H: 4.35" (110 mm)
D: 1.35" (34 mm)
14 | Lutron
Features
Available in ceiling-mount, wall-mount, corner-mount and
hallway options
Lutron XCTTM signal processing technology greatly enhances
the performance of passive infrared (PIR) sensors, enabling them to
detect minor motions that other sensors could not previously detect
Utilizes Lutron reliable Clear Connect® RF technology to
communicate wirelessly with wireless load controllers (wallbox
controls, remote-mount modules, fixtures and/or plug-in devices)
RF range: 60 ft (18 m) line of sight, or 30 ft (9 m) through walls
Vacancy model available to meet CA Title 24 requirements
10-year battery life
Benefits
Front-accessible buttons make set up easy
Sensors have simple test modes to verify ideal locations
during installation
Models
Sensors*
LRF2-OCR2B-P-WH—ceiling-mount occupancy/vacancy sensor
LRF2-OWLB-P-WH—wall-mount occupancy/vacancy sensor
LRF2-OKLB-P-WH—corner-mount occupancy/vacancy sensor
LRF2-OHLB-P-WH—hallway occupancy/vacancy sensor
Accessories
L-CMDPIRKIT—ceiling-mount sensor lens masking kit
L-CRMK-WH—ceiling-mount sensor recess-mounting bracket
WGOMNI-CPN3688—wire guard for ceiling-mount sensor
WGWS-CPN3688—wire guard for wall-mount and hallway sensors
STI-9618-CPN3688—wire guard for corner-mount sensor
* Vacancy-only models available
Lutron ® Clear Connect ®
Wireless Signal Sent
Step 2 Daylight sensor selection
Radio Powr Savr wireless daylight sensor
Design statement: Specify a wireless daylight sensor to dim or switch zones of light in response
to available daylight.
•
Radio Powr Savr wireless
daylight sensor dimensions
W: 1.60" (41 mm)
H: 1.60" (41 mm)
D: 0.7" (17 mm)
•
•
•
•
•
•
•
•
•
Features
Utilizes Lutron reliable Clear Connect RF technology
to communicate wirelessly with wireless load controllers
(wallbox controls, remote-mount modules, and/or plug-in devices);
a load controller can communicate with only one daylight sensor
RF range: 60 ft (18 m) line of sight, or 30 ft (9 m) through walls
Features Lutron reliable proportional daylight open loop control
Has a light range 0-107,000 Lux (0–10,000 fc) and a photopic
response that matches the human eye
Designed to give a linear response to changes in viewed
light level
1 sensor is capable of switching and continuous dimming
of multiple zones
10-year battery life
Benefits
Simple calibration
Multiple ceiling-mount methods available for different ceiling
materials
Front accessible test buttons make set up easy
Models
LRF2-DCRB-WH—daylight sensor
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron | 15
Energi TriPak components
®
Step
3a Overhead light control selection
PowPak relay module
®
Design statement: The PowPak relay module is designed for spaces where local control is not currently
available, but is required.
•
•
•
•
PowPak relay
module dimensions
W: 2.89" (48 mm)
H: 3.44" (87 mm)
D: 1.25" (32 mm)
•
•
•
•
Features
General purpose switch (all lighting loads; motor loads; receptacles)
Receives input from up to 9 Pico® wireless controls, 6 Radio Powr
SavrTM occupancy/vacancy sensors, and 1 Radio Powr Savr
daylight sensor via Lutron reliable Clear Connect® RF technology
Model available with a dry contact closure output for integration
with third-party equipment; contact closure output provides
occupancy status
16 A model features patented Softswitch® technology that
extends relay life to 1,000,000 cycles
120/277 V~ input
Benefits
Save energy with the addition of occupancy sensing,
daylight harvesting and personal control without the need
for additional wires
Button press programming to associate the module with the
Radio Powr Savr sensors and Pico wireless controls
Mounting
Mounts through a 1/2" NPT trade-size knock-out to a junction
box or to a fixture. Can also be mounted inside of a standard
4" x 4" junction box
Models
RMJ-5R-DV-B—5 A lighting loads (1/6 HP @ 120 V~ or 1/3 HP
@ 277 V~ motor loads)
RMJ-5RCCO1-DV-B—5 A lighting loads (1/6 HP @ 120 V~
or 1/3 HP @ 277 V~ motor loads) with (1) contact closure output
RMJ-16R-DV-B—16 A lighting loads (1/2 HP @ 120 V~ or
1 1/2 HP @ 277 V~ motor loads, 15 A 120 V receptacles)
RMJ-16RCCO1-DV-B—16 A lighting loads (1/2 HP @ 120 V~
or 1 1/2 HP @ 277 V~ motor loads, 15 A 120 V~ receptacles) with
(1) contact closure output
16 | Lutron
Lutron ® Clear Connect ®
Wireless Signal Received
PowPak dimming module with EcoSystem
®
Design statement: Specify the PowPak dimming module with EcoSystem for the application that requires
dimming of fluorescent and LED fixtures and simple reconfiguration of lighting zones.
•
•
•
PowPak dimming module
with EcoSystem dimensions
W: 2.89" (48 mm)
H: 3.44" (87 mm)
D: 1.25" (32 mm)
•
•
•
•
•
•
Features
Controls up to 32 EcoSystem, EcoSystem H-Series or Hi-lume®
3D ballasts, or Hi-lume A-Series LED drivers*
Receives input from up to 9 Pico wireless controls, 6 Radio Powr
Savr occupancy/vacancy sensors, and 1 Radio Powr Savr daylight
sensor via Lutron reliable Clear Connect RF technology
Lutron EcoSystem technology facilitates individual ballast
addressing, connection of multiple control devices, and control
of ballasts individually or in groups
120/277 V~ input
Benefits
Enables simple reconfiguration of the space, without having to
move a single wire
Dimming saves money and energy—for every percentage
reduction in lighting level, there is nearly equal reduction in
the energy usage of the dimmed light source
Additional savings can be achieved through occupancy sensing,
daylight harvesting, high-end trim and personal dimming control
without the need for additional wires
Button-press programming means no commissioning required
Mounting
Mounts through a 1/2" NPT trade-size knock-out to a junction
box or to a fixture. Can also be mounted inside of a standard
4" x 4" junction box
Models
RMJ-ECO32-DV-B—controls up to 32 EcoSystem, EcoSystem
H-Series or Hi-lume 3D ballasts, or Hi-lume A-Series LED drivers
* For more information on EcoSystem, EcoSystem H-Series and Hi-lume 3D
ballasts, and Hi-lume A-Series LED drivers, please visit www.lutron.com.
Dimming ballasts require rapid start sockets. For more information, see Lutron
App Note #122.
Lamp Socket Wiring Tester available to easily troubleshoot ballast wiring issues;
see page 37 for ordering information and pricing.
Lutron ® Clear Connect ®
Wireless Signal Received
Lutron | 17
Energi TriPak components
®
Maestro Wireless switch
®
Design statement: Specify a Maestro Wireless switch for applications in which a local switch
already exists.
•
•
•
•
•
Maestro Wireless
switch dimensions
W: 2.94" (75 mm)
H: 4.69" (119 mm)
D: 1.44" (38 mm)
•
•
•
Features
Digital on/off tap switch
Utilizes Lutron reliable Clear Connect® RF technology to
communicate wirelessly with up to 9 transmitting devices
(Radio Powr SavrTM sensors and/or Pico® wireless controls)
Models available to control up to 8 A of lighting load
Controls always operate locally, do not require system control
Available in 27 finishes to complement any décor
Benefits
Save energy with the addition of occupancy sensing and
daylight harvesting without the need for additional wires
Button press programming to associate the control with
Radio Powr Savr sensors and Pico wireless controls
Mounting
Requires a 1-gang U.S. wallbox. 3 1⁄2" (89 mm) deep
recommended, 2 1⁄4" (57 mm) deep minimum
Models
MRF2-8S-DV-XX—8 A lighting, 3 A fan (1/10 HP motor,
120 V only), spec grade, 120–277 V~, no neutral
MRF2-6ANS-XX—6 A lighting, 3 A fan (1/10 HP motor), 120 V~
MRF2-8ANS-120-XX—8 A lighting, 5.8 A fan (1/4 HP motor),
spec grade, 120 V~
(XX in the model number represents color/finish code;
please visit www.lutron.com for color choices.)
18 | Lutron
Lutron ® Clear Connect ®
Wireless Signal Received
Maestro Wireless dimmer
Design statement: Select a Maestro Wireless dimmer for applications in which a local switch already
exists and dimming is required.
•
•
•
•
Maestro Wireless
dimmer dimensions
W: 2.94" (75 mm)
H: 4.69" (119 mm)
D: 1.44" (38 mm)
•
•
•
Features
Digital dimmer with LEDs that indicate light level
Incorporates advanced features such as fade on/fade off,
long fade off, and rapid full on
Utilizes Lutron reliable Clear Connect RF technology to
communicate wirelessly with up to 9 transmitting devices
(Radio Powr Savr sensors and/or Pico wireless controls)
Benefits
Dimming saves money and energy—for every percentage
reduction in lighting level, there is nearly equal reduction in
the energy usage of the dimmed light source
Ability to set high-end trim based on customer requirements
Button-press programming to associate the control with
Radio Powr Savr sensors and Pico wireless controls
Mounting
Requires a 1-gang U.S. wallbox. 3 1⁄2" (89 mm) deep
recommended, 2 1⁄4" (57 mm) deep minimum
Models
MRF2-600M-XX—600 W incandescent/halogen, 120 V~
MRF2-6MLV-XX—600 W/600 VA incandescent/halogen/MLV,
120 V~
MRF2-6ND-120-XX—600 W/600 VA incandescent/halogen/MLV,
spec grade, neutral wire, 120 V~
MRF2-10D-120-XX—1000 W/1000 VA incandescent/halogen/MLV,
spec grade, 120 V~
MRF2-F6AN-DV-XX— 6 A, 3-wire fluorescent, spec grade,
120–277 V~
MRF2-6ELV-120-XX—600 W ELV, 120 V~
(XX in the model number represents color/finish code;
please visit www.lutron.com for color choices.)
Lutron ® Clear Connect ®
Wireless Signal Received
Lutron | 19
Energi TriPak components
®
Step
3b Stairwell fixture selection
Stairwell fixture with PowPak® stairwell controller
Design statement: The stairwell fixture with PowPak stairwell controller saves energy by reducing light
levels when the stairwell is occupied and lowering light levels when it is unoccupied.
•
Stairwell standard
fixture dimensions
W: 51.13" (1299 mm)*
H: 4.375" (111 mm)
D: 3.875" (98 mm)
•
•
•
•
•
NEW Stairwell LED
fixture dimensions
W: 28.25" (718 mm)
H: 4.75" (121 mm)
D: 4.00" (102 mm)
•
•
Features
Incorporates a Lutron digital dimming ballast or LED driver and
wireless lighting control (PowPak stairwell controller) programmed
to occupied and unoccupied light levels specific to the project
Occupied and unoccupied light levels are field adjustable
Utilizes Lutron reliable Clear Connect® RF technology to
communicate wirelessly with up to 9 Radio Powr SavrTM
occupancy/vacancy sensors
Available in 2, 3, or 4 ft**, 1 or 2 lamp, and T8, T8 reduced
wattage, T5HE, or T5HO fluorescent lamp options; and 2 ft,
1500 (17 W) or 2200 (29 W) lumens LED options
Universal input voltage 120/277 V~
Ceiling or wall surface mount
Benefits
Sensor is not integral to the fixture, providing the flexibility to group
multiple fixtures to a single occupancy/vacancy sensor and/or
multiple occupancy/vacancy sensors to a single fixture
Easy to install, wireless communication between devices means
no additional wiring required
Models***
FXSWXX14CP232U51SMXXWH—4 ft, 2 lamp, T8 fluorescent,
factory preset: 50% high-end, 10% low-end; 120/277 V~
FXSWXX14CP232U82SMXXWH—4 ft, 2 lamp, T8 fluorescent,
factory preset: 80% high-end, 20% low-end; 120/277 V~
FXSWXX12SLLC1U51SMXXWH—2 ft, 17 W, 1500 lumens,
4000 K LED, factory preset: 80% high-end, 10% low-end; 120/277 V~
FXSWXX12SLLC1U82SMXXWH—2 ft, 17 W, 1500 lumens,
4000 K LED, factory preset: 10% high-end, 20% low-end; 120/277 V~
* Width provided for 4 ft fixture; consult the product specification submittal
for width measurements for 2 and 3 ft fixtures.
** 8 ft fixture available upon request.
*** Partial list only, for complete list of available fixtures, including information on
the stairwell retrofit kit solution, visit www.lutron.com/stairwellfixture.
20 | Lutron
Lutron ® Clear Connect ®
Wireless Signal Received
Step 4 Task lighting control selection
Maestro Wireless tabletop lamp dimmer and PowPak
plug-in dimming module
®
Design statement: Both the tabletop lamp dimmer and the plug-in dimming module provide control of
task lighting and the ability for remote control. Use the tabletop dimmer to provide personal lamp control.
Select the plug-in module if you wish to conceal the controller.
•
•
•
•
•
Maestro Wireless tabletop
lamp dimmer dimensions
W: 2.44" (62 mm)
H: 3.25" (83 mm)
D: 0.94" (24 mm)
•
•
•
•
•
•
PowPak plug-in dimming
module dimensions
W: 2.3" (58 mm)
H: 3.3" (84 mm)
D: 1.2" (30 mm)
Features
Digital dimmer for use with incandescent/halogen table and floor
lamps up to 300 W
Configure dimming module to switch non-dimmable lighting loads
Light levels can be fine-tuned to the desired light level
Incorporates advanced features such as fade on/fade off, long
fade off, and rapid full on
Utilizes Lutron reliable Clear Connect RF technology to
communicate wirelessly with up to 9 transmitting devices
(Radio Powr Savr sensors and/or Pico® wireless controls)
Controls always operate locally, do not require system control
Available in white or black
Dimming module available in 1- or 3-receptacle models
Benefits
Easy to install, requires no wires or tools
Easily incorporate task lighting into lighting solution, while saving
energy through dimming
Button-press programming to associate the plug-in
dimmer with the same Radio Powr Savr sensors and Pico
wireless controls that control the overhead lighting
Models
MRF2-3LD-XX—300 W tabletop lamp dimmer,
incandescent/halogen, 120 V~
MRF2-3PD-1-XX—300 W plug-in dimming module,
1-receptacle, incandescent/halogen, 120 V~
MRF2-3PD-3-XX—300 W plug-in dimming module,
3-receptacle, incandescent/halogen, 120 V~
(XX in the model number represents color/finish code;
please visit www.lutron.com for color choices.)
Lutron ® Clear Connect ®
Wireless Signal Received
Lutron | 21
Energi TriPak components
®
Step 5 Plug load control selection
PowPak plug-in appliance module
®
Design statement: Specify a PowPak plug-in appliance module to directly control plug loads,
such as computer monitors or printers.
•
•
•
•
PowPak plug-in appliance
module dimensions
W: 2.3" (58 mm)
H: 3.3" (84 mm)
D: 1.2" (30 mm)
•
•
•
•
Features
Utilizes Lutron reliable Clear Connect® RF technology to
communicate wirelessly with up to 9 transmitting devices
(Radio Powr SavrTM occupancy/vacancy sensors and/or Pico®
wireless controls)
Control up to 15 A of general purpose load (1/2 HP motor load);
no minimum load required
Patented Softswitch® technology extends relay life to
1,000,000 cycles
Can be hidden discretely behind furniture
Controls always operate locally, do not require system control
Available in white or black, and 1- or 3-receptacle models
Benefits
Save energy by switching off plug loads when space
is unoccupied
Button-press programming to associate the plug-in appliance
module with the same Radio Powr Savr occupancy/vacancy
sensors and Pico wireless controls that control the
overhead lighting
Models
MRF2-15APS-1-XX—15 A plug-in appliance module,
1-receptacle, 120 V~
MRF2-15APS-3-XX—15 A plug-in appliance module,
3-receptacle, 120 V~
(XX in the model number represents color/finish code;
please visit www.lutron.com for color choices.)
22 | Lutron
Lutron ® Clear Connect ®
Wireless Signal Received
PowPak relay module with Softswitch
Design statement: Specify a PowPak relay module with Softswitch to switch receptacles,
controlling plug loads which consume energy when space is not in use.
•
•
•
PowPak relay module
with Softswitch dimensions
W: 2.89" (48 mm)
H: 3.44" (87 mm)
D: 1.25" (32 mm)
•
•
•
•
•
Features
16 A general purpose switch for control of 15 A 120 V~
receptacles
Receives input from up to 9 Pico wireless controls, 6 Radio Powr
Savr occupancy/vacancy sensors, and 1 Radio Powr Savr
daylight sensor via Lutron reliable Clear Connect RF technology
Model available with a dry contact closure output for integration
with third-party equipment; contact closure output provides
occupancy status
Patented Softswitch technology extends relay life to
1,000,000 cycles
120/277 V~ input
Benefits
Save energy by switching off power to plug loads when space
is unoccupied
Button press programming to associate the module with the
Radio Powr Savr sensors and Pico wireless controls
Mounting
Mounts through a 1/2" NPT trade-size knock-out to a junction
box or to a fixture. Can also be mounted inside of a standard
4" x 4" junction box
Models
RMJ-16R-DV-B—16 A general purpose switch
(15 A 120 V~ receptacles)
RMJ-16RCCO1-DV-B—16 A general purpose switch
(15 A 120 V~ receptacles) with (1) contact closure output
Lutron ® Clear Connect ®
Wireless Signal Received
Lutron | 23
Energi TriPak components
®
Step 6 Third-party integration control selection
PowPak contact closure output module
®
Design statement: A PowPak contact closure output module is designed for spaces where integration
with third-party equipment through contact closures is desired.
•
•
•
•
•
PowPak contact
closure output
module dimensions
W: 2.89" (48 mm)
H: 3.44" (87 mm)
D: 1.25" (32 mm)
Features
Single dry contact closure device
Receives input from up to 9 Pico® wireless controls, 6 Radio
Powr SavrTM occupancy/vacancy sensors, and 1 Radio Powr Savr
daylight sensor via Lutron reliable Clear Connect® RF technology
Voltage: 24 V AC/DC
Maximum load of 1 A @ 24 VDC or 0.5 A @ 24 VAC; no minimum
load required
Maintained output type
•
Benefits
Button-press programming to associate the module with the
Radio Powr Savr sensors and Pico wireless controls
•
Mounting
Screw tabs provided for surface mounting. Can also be mounted
to a 1/2" NPT trade-size knock-out on a junction box
Models
RMJ-CCO1-24-B—(1) contact closure output
24 | Lutron
Lutron ® Clear Connect ®
Wireless Signal Received
Step
7a Wireless control selection
Pico wireless controls
®
Design statement: Use a Pico wireless control anywhere in the space to control loads with a touch
of a button.
•
•
•
3-button
with Raise/
Lower
2-button
with Raise/
Lower
•
•
•
3-button
2-button
Pico wireless control
dimensions
W: 1.28" (33 mm)
H: 2.60" (66 mm)
D: 0.33" (8 mm)
Features
Utilizes Lutron reliable Clear Connect RF technology to
communicate wirelessly with wireless load controllers (wallbox
controls, remote-mount modules, and/or plug-in devices)
RF range: 30 ft (9 m) through wall
Available in multiple button configurations with options for preset
and raise/lower buttons
10-year battery life
Benefits
Easily add a new and/or additional point of control without the
need for new wires
Easy configuration for use as a handheld control, car visor
control, wall-mount control, or tabletop control with use of the
optional pedestal
Models
PJ-3BRL-GXX-YYY—3-button with Raise/Lower
PJ-2BRL-GXX-YYY—2-button with Raise/Lower
PJ-3B-GXX-YYY—3-button
PJ-2B-GXX-YYY—2-button
(XX in the model number represents color/finish code and YYY
represents labeling options. Please visit www.lutron.com/Pico
for more information.)
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron | 25
Energi TriPak components
®
Step
7b Wireless control accessories selection
Pico wireless control accessories
®
Design statement: Use accessories to enhance the flexibility of the Pico wireless control.
•
•
•
•
•
•
Wall-mount with Claro faceplate
with Pico faceplate adapter
Wall-mount with Pico single
Euro faceplate with adapter
Single and double pedestals
26 | Lutron
Features
Pico wireless controls are designed to fit in the opening of a
Claro® or Euro Pico faceplate
Claro faceplates are available in finishes to complement the
Pico wireless control
European-style faceplates with adapters afford an architectural-style
appearance and are available in both matte and metal finishes
Tabletop pedestals are offered to support up to 4 Pico wireless
controls and are available in white and black
Benefits
Pico faceplate adapter and Euro Pico faceplate with adapter
allow for easy installation of the Pico wireless control in
a faceplate
Tabletop pedestals help ensure that the Pico wireless control
is always within reach
Models
Wall-mount accessories
PICO-FP-ADAPT—Pico faceplate adapter for Claro faceplate
CW-1-XX—Claro 1-gang faceplate
CW-2-XX—Claro 2-gang faceplate
CW-3-XX—Claro 3-gang faceplate
CW-4-XX—Claro 4-gang faceplate
PFP-1-B-FXX-CPN5692—Single Euro Pico faceplate with adapter
PFP-2-B-FXX-CPN5692—Double Euro Pico faceplate with adapter
Tabletop accessories
L-PED1-XX—Single pedestal
L-PED2-XX—Double pedestal
L-PED3-XX—Triple pedestal
L-PED4-XX—Quadruple pedestal
(XX in the model number represents color/finish code;
please visit www.lutron.com for color choices.)
Lutron ® Clear Connect ®
Wireless Signal Sent
How it works
Stairwell Retrofit Solution
The stairwell fixture with PowPak® stairwell controller communicates wirelessly with Radio Powr SavrTM
occupancy/vacancy sensors. Based on the stairwell occupancy information received from the sensors, the
PowPak stairwell controller automatically adjusts the light output. The occupied and unoccupied light levels
are field adjustable to meet the project’s code requirements.
Unoccupied: 10% light level
Occupied: 50% light level
3
3
2
2
1
1
Stairwell standard fixture with
PowPak stairwell controller
Radio Powr Savr
occupancy/vacancy sensor
(wall-mount)
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron ® Clear Connect ®
Wireless Signal Received
Lutron | 27
How it works
Variable Air Volume (VAV) integration
In response to information received from a Radio Powr SavrTM occupancy/vacancy sensor, the PowPak®
contact closure output module communicates room occupancy to the VAV terminal unit. By not heating
or cooling an unoccupied room, the electricity consumed by the HVAC system can be reduced.
Filter
Cooling Supply
coil
fan
C
C
Damper open
Occupied
Radio Powr Savr
occupancy/vacancy
sensor (ceiling-mount)
Damper closed
Unoccupied
PowPak contact closure
output module
Lutron ® Clear Connect ®
Wireless Signal Sent
Lutron ® Clear Connect ®
Wireless Signal Received
28 | Lutron
Plug load control by switching receptacles
Plug loads, such as task lighting, computer monitors, and printers, account for greater than 5% of
commercial electricity usage2. By utilizing the PowPak relay module with Softswitch® and a Radio Powr
Savr occupancy/vacancy sensor to switch receptacles, energy savings can be obtained. The occupancy/
vacancy sensor communicates room occupancy wirelessly to the relay module. Based on the occupancy
status received, the relay module switches the power to the receptacles on or off, reducing the amount
of energy consumed.
Occupied
Radio Powr Savr
occupancy/vacancy
sensor (ceiling-mount)
Unoccupied
PowPak relay module
with Softswitch
Lutron ® Clear
Clear Connect
Connect®®
Señal inalámbrica
enviada
Wireless
Signal Sent
Lutron ® Clear Connect ®
Wireless Signal Received
Sources located on back cover.
Lutron | 29
Alternate stand-alone solution
Maestro occupancy sensing controls*
®
Design statement: Maestro occupancy sensing switches and dimmers are alternate
energy-saving solutions for smaller spaces with unobstructed views.
•
•
•
•
•
Maestro occupancy
sensing switch dimensions
W: 2.83” (75 m)
H: 4.61” (119 m)
D: 1.125” (30 mm)
•
•
•
•
•
•
NEW Maestro dual circuit
occupancy sensing switch dimensions
W: 2.83” (75 m)
H: 4.61” (119 m)
D: 1.125” (30 mm)
30 | Lutron
Features
Lutron XCTTM signal processing technology greatly enhances the
performance of PIR sensors, enabling them to detect minor motions
that other sensors could not previously detect
180 ˚ sensor field-of-view, must have unobstructed view
Up to 30 ft x 30 ft major motion coverage and 20 ft x 20 ft minor
motion coverage
Adjustable timeout - 1, 5, 15, or 30 minutes
High-low sensitivity adjustment
Vacancy/partial-on models available to meet CA Title 24 requirements
Switch models feature ambient light detection, and are available in
single or dual circuit
Available in 27 colors to complement any décor
Benefits
Save energy automatically with the simple addition of
occupancy/vacancy sensing
Dual circuit sensor provides bi-level control of two circuits, as
required by specific energy codes
Easy to install, directly replaces an existing control with no
new wiring required
Models**
Switch
MS-OPS2-XX—2 A lighting, occupancy/vacancy, 120 V~
MS-OPS5M-XX—5 A lighting, 3 A fan (1/10 HP motor),
occupancy/vacancy, 120 V~
MS-OPS6M2-DV-XX—6 A lighting, 3 A fan (1/10 HP motor,
120 V only), occupancy/vacancy, 120-277 V~
MS-OPS6M2N-DV-XX—6 A lighting, 3 A fan (1/10 HP motor,
120 V only), occupancy/vacancy, neutral wire, 120-277 V~
MS-OPS6-DDV-XX—dual circuit, 6 A lighting, 3 A fan (1/10 HP
motor, 120 V only) per circuit, occupancy mode, 120-277 V~
Dimmer
MSCL-OP153M-XX—600 W incandescent/halogen,
150 W dimmable CFL/LED, occupancy/vacancy, 120 V~
(XX in the model number represents color/finish code;
please visit www.lutron.com for color choices.)
Storage room—switching, 1 zone
Line Voltage
Product key:
Maestro occupancy sensing switch
(mounted in 1-gang Claro® faceplate)
Switched lighting load
* Maestro occupancy/vacancy sensing switches and dimmers are
not components of Energi TriPak® and cannot communicate with
Radio Powr SavrTM sensor or Pico® wireless controls.
** Vacancy/partial-on models available
Lutron | 31
Sensor coverage diagrams
Ceiling-mount, 360°
Wall-mount*, 180°
Coverage varies by ceiling height
1,500 ft2—minor motion ; 3,000 ft2—major motion
Floor view
Top view
25 ft
(7.6 m)
Ceiling
8 ft
(2.4 m)
Ceiling
height
15 ft
(4.6 m)
Floor
15 ft 12 ft
9 ft
6 ft
3 ft
0 ft
3 ft
6 ft
9 ft
12 ft 15 ft
(4.6 m) (3.7 m) (2.7 m) (1.8 m) (0.9 m) (0 m) (0.9 m) (1.8 m) (2.7 m) (3.7 m) (4.6 m)
Top view
0 ft
(0 m)
15 ft
(4.6 m)
Sensor
25 ft
(7.6 m)
50 ft
(15.2 m)
0 ft
(0 m)
60 ft
(18.3 m)
Occupant
9 ft
6 ft
3 ft
0 ft
3 ft
6 ft
9 ft
(2.7 m) (1.8 m) (0.9 m) (0 m) (0.9 m) (1.8 m) (2.7 m)
Key:
Minor motions
Major motion
Ceiling-mount sensor coverage chart (for sensor mounted in center of room)
Ceiling height
Maximum room dimensions for complete
floor coverage
Radius of coverage
at floor
8 ft
(2.4 m)
18 x 18 ft (5.5 x 5.5 m)
13 ft
(4.0 m)
9 ft
(2.7 m)
20 x 20 ft (6.1 x 6.1 m)
14.5 ft
(4.4 m)
10 ft (3.0 m)
22 x 22 ft (6.7 x 6.7 m)
16 ft
(4.9 m)
12 ft (3.7 m)**
26 x 26 ft (7.9 x 7.9 m)
19 ft
(5.8 m)
32 | Lutron
* Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m).
** 12 ft (3.7 m) is the maximum mounting height allowed.
Corner-mount*, 90°
In-wall, 180°
1,225 ft2—minor motion; 2,500 ft2—major motion
400 ft2 —minor motion; 900 ft2—major motion
Top view
Top view
50 ft
(15.2 m)
35 ft
(10.7 m)
35 ft
(10.7 m)
0 ft
(0 m)
0 ft
(0 m)
35 ft
(10.7 m)
50 ft
(15.2 m)
0 ft
(0 m)
25 ft
(7.7 m)
15 ft
(4.6 m)
0 ft
(0 m)
15 ft
(4.6 m)
25 ft
(7.7 m)
Hallway*, long narrow field of view
Coverage varies by hallway width and length
Top view
10 ft
(3.0 m)
5 ft
(1.5 m)
0 ft
(0 m)
5 ft
(1.5 m)
10 ft
(3.0 m)
150 ft
(45.7 m)
0 ft
(0 m)
Hallway sensor maximum recommended length chart (sensor centered within hallway)
Width of hallway
Length of hallway
6 ft
(1.6 m) or less
50 ft
(15.2 m)
8 ft
(2.4 m)
100 ft
(30.5 m)
10 ft
(3.0 m) or more
150 ft
(45.7 m)
* Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m).
Lutron | 33
Ordering information
Model number
Description
List Price (US)
Maestro Wireless® switches*
MRF2-6ANS-XX
MRF2-8ANS-120-XX
MRF2-8S-DV-XX
6 A lighting, 3 A fan (1/10 HP motor), 120 V~
8 A lighting, 5.8 A fan (1/4 HP motor), spec grade, 120 V~
8 A lighting, 3 A fan (1/10 HP motor, 120 V only), spec grade,
120–277 V~ , no neutral
88.00
120.00
150.00
Maestro Wireless dimmers*
MRF2-600M-XX
MRF2-6MLV-XX
MRF2-6ND-120-XX
MRF2-10D-120-XX
MRF2-F6AN-DV-XX
MRF2-6ELV-120-XX
600 W incandescent/halogen, 120 V~
600 W/600 VA incandescent/halogen/MLV, 120 V~
600 W/600 VA incandescent/halogen/MLV, spec grade,
neutral wire, 120 V~
1000 W/1000 VA incandescent/halogen/MLV,
spec grade, 120 V~
6 A lighting, 3-wire fluorescent, spec grade,
120–277 V~
600 W ELV, 120 V~
88.00
100.00
130.00
130.00
180.00
189.00
Maestro Wireless tabletop lamp dimmer
MRF2-3LD-XX
300 W lamp dimmer, incandescent/halogen, 120 V~
130.00
PowPak® stairwell fixtures**
FXSWXX14CP232U51SMXXWH
4 ft, 2 lamp, T8 fluorescent, factory preset: 50% high-end,
10% low-end, 120/277 V~
FXSWXX14CP232U82SMXXWH
4 ft, 2 lamp, T8 fluorescent, factory preset: 80% high-end,
20% low-end, 120/277 V~
FXSWXX12SLLC1U51SMXXWH
2 ft, 17 W, 1500 lumens, 4000 K LED, factory preset: 50% high-end,
10% low-end, 120/277 V~
FXSWXX12SLLC1U82SMXXWH
2 ft, 17 W, 1500 lumens, 4000 K LED, factory preset: 80% high-end,
20% low-end, 120/277 V~
390.00
390.00
500.00
500.00
PowPak relay module
RMJ-5R-DV-B
RMJ-5RCCO1-DV-B
RMJ-16R-DV-B
RMJ-16RCCO1-DV-B
34 | Lutron
5 A general purpose switch
5 A general purpose switch with (1) contact closure output
16 A general purpose switch
16 A general purpose switch with (1) contact closure output
89.00
99.00
109.00
119.00
Model number
Description
List Price (US)
PowPak dimming module with EcoSystem®
RMJ-ECO32-DV-B
Controls up to 32 EcoSystem, EcoSystem H-Series or
Hi-lume® 3D ballasts, or Hi-lume A-Series LED drivers
170.00
EcoSystem H-Series ballasts†
EHDT832MU110
EHDT832MU117
EHDT832MU210
EHDT832MU217
EHDT528MU110
EHDT528MU210
EHDT554MU110
EHDT554MU210
EHDT817MU110
EHDT817MU210
EHDT825MU110
EHDT825MU210
EHDT514MU110
EHDT514MU210
EHDT521MU110
EHDT521MU210
EHDT524MU110
EHDT524MU210
EHDT539MU110
EHDT539MU210
EHDT832GU310
EHDT832GU317
T8 linear, 32 W, 1-lamp, 120-27 V~, 1.0 ballast factor
T8 linear, 32 W, 1-lamp, 120-277 V~, 1.17 ballast factor
T8 linear, 32 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T8 linear, 32 W, 2-lamp, 120-277 V~, 1.17 ballast factor
T5 linear, 28 W, 1-lamp, 120-277 V~, 1.0 ballast factor
T5 linear, 28 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T5HO linear, 54 W, 1-lamp, 120-277 V~, 1.0 ballast factor
T5HO linear, 54 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T8 linear, 17 W, 1-lamp, 120-277 V~, 1.0 ballast factor
T8 linear, 17 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T8 linear, 25 W, 1-lamp, 120-277 V~, 1.0 ballast factor
T8 linear, 25 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T5 linear, 14 W, 1-lamp, 120-277 V~, 1.0 ballast factor
T5 linear, 14 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T5 linear, 21 W, 1-lamp, 120-277 V~, 1.0 ballast factor
T5 linear, 21 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T5HO linear, 24 W, 1-lamp, 120-277 V~, 1.0 ballast factor
T5HO linear, 24 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T5HO linear, 39 W, 1-lamp, 120-277 V~, 1.0 ballast factor
T5HO linear, 39 W, 2-lamp, 120-277 V~, 1.0 ballast factor
T8 linear, 32 W, 3-lamp, 120-277 V~, 1.0 ballast factor
T8 linear, 32 W, 3-lamp, 120-277 V~, 1.17 ballast factor
79.00
79.00
79.00
79.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
89.00
129.00
129.00
PowPak contact closure output module
RMJ-CCO1-24-B
(1) contact closure output
89.00
PowPak plug-in dimming module
MRF2-3PD-1-XX
MRF2-3PD-3-XX
300 W, 1-receptacle, incandescent/halogen, 120 V~
300 W, 3-receptacle, incandescent/halogen, 120 V~
99.00
99.00
PowPak plug-in appliance module
MRF2-15APS-1-XX
MRF2-15APS-3-XX
15 A plug-in switch, 1-receptacle, 120 V~
15 A plug-in switch, 3-receptacle, 120 V~
* Price indicated for gloss finish products.
** Partial list only, for complete list of available fixtures visit www.lutron.com/stairwellfixture.
†
Dimming ballasts require rapid start sockets. For more information, see Lutron App Note #122.
99.00
99.00
Lutron | 35
Ordering information
Model number
Description
List Price (US)
Radio Powr SavrTM occupancy/vacancy sensors*
LRF2-OCR2B-P-WH
LRF2-OWLB-P-WH
LRF2-OKLB-P-WH
LRF2-OHLB-P-WH
Ceiling-mount, 360° field of view, occupancy/vacancy sensor
Wall-mount, 180° field of view, occupancy/vacancy sensor
Corner-mount, 90° field of view, occupancy/vacancy sensor
Hallway, occupancy/vacancy sensor
85.00
85.00
85.00
85.00
Simple Energy Retrofit packages**
MRF2-1S8A-1OC*
MRF2-1S8A-1OW
MRF2-1S8A-1OK
MRF2-1S8A-1OH
MRF2-2S8A-1OW
(1) Maestro Wireless® 8 A, no neutral switch, 120/277 V~, (1) Claro®
1-gang faceplate, (1) Radio Powr Savr wireless ceiling-mount
occupancy/vacancy sensor
(1) Maestro Wireless 8 A, no neutral switch, 120/277 V~, (1) Claro
1-gang faceplate, (1) Radio Powr Savr wireless wall-mount
occupancy/vacancy sensor
(1) Maestro Wireless 8 A, no neutral switch, 120/277 V~, (1) Claro
1-gang faceplate, (1) Radio Powr Savr wireless corner-mount
occupancy/vacancy sensor
(1) Maestro Wireless 8 A, no neutral switch, 120/277 V~, (1) Claro
1-gang faceplate, (1) Radio Powr Savr wireless hallway
occupancy/vacancy sensor
(2) Maestro Wireless 8 A, no neutral switches, (1) Claro
2-gang faceplate, (1) Radio Powr Savr wireless wall-mount
occupancy/vacancy sensor
198.00
198.00
198.00
198.00
350.00
Radio Powr Savr occupancy/vacancy sensors accessories
L-CMDPIRKIT
L-CRMK-WH
WGOMNI-CPN3688
WGWS-CPN3688
STI-9618-CPN3688
Ceiling-mount sensor lens masking kit
Ceiling-mount recess-mounting bracket
Wire guard for ceiling-mount sensor, white
Wire guard for wall-mount and hallway sensors, white
Wire guard for corner-mount sensor, white
11.80
17.00
80.00
80.00
80.00
Radio Powr Savr daylight sensor
LRF2-DCRB-WH
Ceiling-mount daylight sensor
120.00
Pico® wireless controls†
PJ-3BRL-GWH-YYY
PJ-2BRL-GWH-YYY
PJ-3B-GWH-YYY
PJ-2B-GWH-YYY
PJ-3BRL-GXX-YYY
PJ-2BRL-GXX-YYY
PJ-3B-GXX-YYY
PJ-2B-GXX-YYY
36 | Lutron
3-button with Raise/Lower, white only
2-button with Raise/Lower, white only
3-button, white only
2-button, white only
3-button with Raise/Lower
2-button with Raise/Lower
3-button
2-button
25.00
25.00
25.00
25.00
56.00
56.00
56.00
56.00
Model number
Description
List Price (US)
Pico accessories
L-PED1-XX
L-PED2-XX
L-PED3-XX
L-PED4-XX
PICO-FP-ADAPT
PFP-1-B-FXX-CPN5692††
PFP-2-B-FXX-CPN5692††
Pico wireless control single pedestal
Pico wireless control double pedestal
Pico wireless control triple pedestal
Pico wireless control quadruple pedestal
Pico wireless control faceplate adapter
Single Euro Pico faceplate with adapter
Double Euro Pico faceplate with adapter
15.00
30.00
100.00
120.00
8.00
40.00
44.00
Lamp Socket Wiring Tester
FDB-LSWT-T5/T8
600 V, 100 KHz, 0.125 A max, CAT III
180.00
Maestro® occupancy/vacancy sensing switches*,‡
MS-OPS2-XX
MS-OPS5M-XX
MS-OPS6M2-DV-XX
MS-OPS6M2N-DV-XX
MS-OPS6-DDV-XX
2 A lighting, occupancy/vacancy sensing switch, 120 V~
5 A lighting, 3 A fan (1/10 HP motor),
occupancy/vacancy sensing switch, 120 V~
6 A lighting, 3 A fan (1/10 HP motor, 120 V only),
occupancy/vacancy sensing switch, 120-277 V~
6 A lighting, 3 A fan (1/10 HP motor, 120 V only),
occupancy/vacancy sensing switch, neutral wire, 120-277 V~
dual circuit, 6 A lighting, 3 A fan (1/10 HP motor, 120 V only) per circuit,
occupancy mode sensing switch, 120-277 V~
29.00
41.00
49.00
49.00
89.00
Maestro occupancy/vacancy sensing dimmers*,‡
MSCL-OP153M-XX
600 W incandescent/halogen, 150 W dimmable CFL/LED,
occupancy/vacancy sensing dimmer, 120 V~
54.00
Maestro Wireless/Maestro occupancy sensing control companion devices‡
MA-AS-XX
MA-AS-277-XX
MA-R-XX
MA-R-277-XX
Multi-location companion switch, 120 V~
Multi-location companion switch, 277 V~
Multi-location companion dimmer, 120 V~
Multi-location companion dimmer, 277 V~
35.50
44.00
27.50
44.00
Claro® 1-gang faceplate
Claro 2-gang faceplate
Claro 3-gang faceplate
Claro 4-gang faceplate
4.90
9.80
15.00
20.00
Faceplates
CW-1-XX
CW-2-XX
CW-3-XX
CW-4-XX
** Available in white only.
†
Price indicated for light or power text/icon labeling only.
††
Price indicated for Arctic White and Midnight only, contact Lutron for additional color options and pricing.
‡
Price indicated for gloss finish only.
Lutron | 37
Sources
1 Compared with manual (non-automated) controls, up to 60% lighting energy savings is possible on projects that utilize all of
the lighting control strategies (occupancy sensing, high-end trim, personal control and daylight harvesting). Actual energy
savings may vary, depending on prior occupant usage, among other factors.
2 Energy Information Administration, 2003 Commercial Buildings Energy Consumption Survey, released September 2008.
3 Light Right Consortium. Research Study on the Effects of Lighting on Office Workers. http://www.lightright.org.research/index.htm.
4 Galasiu AD, et al. 2007. Energy saving lighting control systems for open-plan offices: A field study. Leukos. 4(1) pg 7-29.
5 VonNieda B, Maniccia D, & Tweed A. 2000. An analysis of the energy and cost savings potential of occupancy sensors for
commercial lighting systems. Proceedings of the Illuminating Engineering Society. Paper #43.
6 Reinhart CF. 2002. Effects of interior design on the daylight availability in open plan offices. Study of the American
Commission for an Energy Efficient Environment (ACE) Conference Proceedings. To achieve maximum lighting savings,
automated shades are utilized.
7 Williams A, et al. 2012. Lighting Controls in Commercial Buildings. Leukos. 8(3) pg 161-180.
8 Ecos. 2011. Commercial office plug load savings assessment. California Energy Commission PIER Program.
9 Lutron study based on reduction in heating (base 60°F) and cooling (base 55°F) degree days with a 2°F thermostat setback
and 60% space un-occupancy. EnergyPlus modeling simulations were conducted and predicted similar savings.
10 Phillips, R. W. (1997). Educational Facility Age and the Academic Achievement of Upper Elementary School Students.
Unpublished Doctoral Dissertation. University of Georgia.
www.lutron.com
World Headquarters 1.610.282.3800
Technical Support Center 1.800.523.9466 (Available 24/7)
Customer Service/Quotes 1.888.LUTRON1 (1.888.588.7661)
© 06/2013 Lutron Electronics Co., Inc.
P/N 367-2110 REV E
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement