WESCHLER INSTRUMENTS

Newport

Digital Indicator Controllers

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: Q2001-CVR6

A

A

B

C

D

E

F

B C D – E F

Display Resolution and Case Style

Q2 ±1999 Counts (3 1 ⁄

2

-digits)

Q3 ±1999 with “Infinity

Family Bezel and Adapter”

Q9 ±9999 Counts (4-digits)

Q8 ±9999 with “Infinity

Family Bezel and Adapter”

Display Type and Meter Power

4

6

0

2

8

LED, 120 VAC (49/440 Hz) (BQ20 or BQ90)

LED, 240 VAC (49/440 Hz) (BQ22 or BQ92)

LED, 9–32 VDC (isolated) (BQ24 or BQ94)

LED, 5 VDC** (BQ26 or BQ96)

LED, 24 VAC (BQ28 or BQ98)

A LED, 26-–56 VDC (isolated) (BQ2A or BQ9A)

**Not available with AC AVG or True RMS inputs

Analog Output Adders

4

6

2

3

Max one analog output in addition to recorder output

0 ±1 or ±2 V recorder output, non-isolated

1 0–5 VDC, non-isolated (BA01)

0–10 VDC, non-isolated (BA01)

0–1 mA, source or sink, non-isolated (BA01)

4–20 mA, source or sink, non-isolated (BA01)

4–20 mA, isolated (BA03)

1

4

Control Output Adders

0 None

Dual-Setpoint 10A Relay (BDT1)

BCD (BDD2)

5 Single-Setpoint 10A Relay (BDS1)

Signal Conditioning Input Adders

Select from Input Table

Green LEDs for Display

G Green

0 None

11

INPUT TABLE

Code Q2000/Q3000

DC Voltage Input

AVR1 ±199.9 mV

AVR2

AVR3

AVR4

±1.999V

±19.99V

±199.9V

DC Current Input

BCR1 ±19.99 µA

BCR2

BCR3

BCR4

BCR5

BCR6 ±1.999A

AC AVG Voltage Input

CVR2 199.9 mV

CVR3

CVR4

CVR5

1.999V

19.99V

199.9V

CVR6 650V

AC AVG Current Input

DCR1 19.99 µA

DCR2

DCR3

DCR4

±199.9 µA

±1.999 mA

±19.99 mA

±199.9 mA

199.9 µA

1.999 mA

19.99 mA

Q8000/Q9000

±99.99 mV

±999.9 mV

±9.999V

±99.99V

±9.999 µA

±99.99 µA

±999.9 µA

±9.999 mA

±99.99 mA

±999.9 mA

99.99 mV

999.9 mV

9.999V

99.99V

650.0V

9.999 µA

99.99 µA

999.9 µA

9.999 mA

DCR5

DCR6

199.9 mA

1.999A

99.99 mA

999.9 mA

DCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000,

(4) 5A = 300, (5) 5A = 500

Quanta® Standard Features

• Field Selectable Input Ranges

• Recorder Analog Output

• Front-Panel Accessible

Span Adjustment

• Bright, 0.56"

(14.2 mm) LED Display

• Display Hold and Test

• Screw-Terminal Barrier Strip

• Optional Relay Outputs

• 1⁄8 DIN Case

Options

• Analog Output for

User-Selected Span

• Single-Setpoint 10A

SPDT Relay

• Dual-Setpoint with Two

10A SPDT Relays

• Parallel BCD Output,

Isolated

Quanta

INPUT TABLE (CONT’D)

Code Q2000/Q3000

True-RMS Voltage Input

FVR2

FVR3

199.9 mV

1.999V

FVR4

FVR5

19.99V

199.9V

FVR6 650V

True-RMS Current Input

GCR1

GCR2

GCR3

GCR4

GCR5

19.99 µA

199.9 µA

1.999 mA

19.99 mA

199.9 mA

Q8000/Q9000

99.99 mV

999.9 mV

9.999V

99.99V

650.0V

9.999 µA

99.99 µA

999.9 µA

9.999 mA

99.99 mA

GCR6 1.999A

999.9 mA

GCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000,

(4) 5A = 300, (5) 5A = 500

Frequency/Rate Input (100 mV Hystersis):

H 1000 Hz = 1000

Type J Thermocouple Input

1000 Hz = 0–9999

JDC1

JDF1

-40 to +760°C

-40 to +1400°F

Type K Thermocouple Input

KDC1 -40 to +1260°C

-40.0 to +760.0°C

-40.0 to +999.9°F

-40.0 to +999.9°C

-40.0 to +999.9°F KDF1 -40 to +1999°F

Type T Thermocouple Input

TDC1 -184 to +371°C -184.0 to +371.0°C

TDF1 -300 to +700°F -300.0 to +700.0°F

RTD (Pt 100) Input Alpha = 0.00385

MDC1

MDF1

-200 to +830°C

-328 to +1526°F

-200.0 to +830.0°C

-328.0 to +999.9°F

RTD Input, High Resolution Alpha = 0.00385

RDC1 -199.9 to +199.9°C Not available with Q8/Q9

RDF1 -199.9 to +199.9°F Not available with Q8/Q9

3-Wire Ratio Potentiometer Input

NPR1

NPR2

1000 = 1 kOhm

1000 = 5 kOhm

2- or 4-Wire Resistance Input

OOR1 19.99 Ohm

9999 = 1 kOhm

9999 = 5 kOhm

OOR2

OOR3

199.9 Ohm

1999 Ohm

Not available with Q8/Q9

Not available with Q8/Q9

Not available with Q8/Q9

OOR4 19.99 kOhm

Process Signal Input

Not available with Q8/Q9

P 4–20 mA = 0–100.0

4–20 mA = 0–99.99

Process Signal Input Excitation set to 15 VDC

E 4–20 mA = 0–100.0

4–20 mA = 0–99.99

Strain-Gage/Microvolt Input Excitation set to 10 VDC (30 mA max)

S ±100 mV = ±100.0

±100 mV = ±99.99

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Weschler

Quatro BarGraph Meters

• 101 segment bargraph in red, green or tricolor

• 4-digit 10000 count LED display

• 6" edgewise & 9/64 DIN cases

• Vertical or horizontal orientation

NEW

Features

• Single & dual bar configurations

• Adjustable bargraph span

• Bargraph center zero mode

• Four programmable setpoints

• Front panel setpoint status indicators

• Up to 4 relay outputs for control and alarms

• Analog retransmit option with adjustable span

• Wide power supply range (AC & DC)

• Sensor excitation to power 4-20mA transmitters or bridge type sensors

Direct Measurement of

DC Current

AC Current

DC Voltage

AC Voltage

Frequency

Process Loops

Thermocouples

RTDs

Load Cells/Strain Gauges

Speed Pickups/RPM

Pressure

Resistance/Potentiometers

Style A combines a precision 4 digit LED display with a 101 segment bargraph. The bar can be set to display any part of the digital range, from a minimum of 100 counts to the full 12000

A/D counts. Higher bar resolution is useful for applications where the normal operating range is only a portion of the full scale input. Style A offers 4 levels of display brightness, which can be set from the front panel.

Style A

ORDERING INFORMATION

Select desired code for each category to buiId the 15 digit part number.

Example Part Number: MAVTRCXPD1AKXXX

Style C offers a 101 segment red, green or tricolor bar, without digital display. The bar can be set to grow from the bottom or the center of the scale. The center mode is normally used for center zero but can also show deviation around a half-scale value.

A B C D E G H I X X X

Style C

A Type

L 4 digit, 9/64 DIN Case

Input (Partial list continued)

M1 RPM, 99.99/999.9/9999Hz,

M 4 digit, 6" Edgewise Case

B Style

A Digital & bar

C Single bar (no digtial)

D Dual bar (no digital)

50mV-30V, w/24V Exc. (Style A)

PD Universal Process,

2V/5V/10V/20V/200V/2mA/20 mA/Custom

PE Dual Process,

The dual bar configuration (Style D) can display two process variables, using the Dual Process input card (PE). Any combination of red and green bars can be specified. Two setpoints are available for each channel. The dual input card may also be used to display

C Orientation

2V/10V/20V/200V/2mA/20mA

/Custom (style D only) one process variable on the left bar and two tracking setpoints on the right bar. In this mode, setpoint 1 is determined by the channel

V Vertical

H Horizontal RD Resistance, 2kΩ

SA Strain Gage, 5/10VDC Excitation,

Excitation, 20/2mV/V, 4-wire

TD Thermocouple, J Type (0-1400°F)

2 input signal. Setpoint 2 is offset from setpoint 1 by a fixed (user selectable) amount.

D Bar Color

R Red

G Green

T Tricolor (Style A or C only)

E Second Bar Color (right or bottom bar)

20/2mV/V, 4/6-wire

SD Pressure/Load Cell, 5/10V

Style D

The dual bar style can be used with a single channel input module

& 4 set points. The left bar displays the process signal; the right bar displays min/max.

R Red (Style D only)

G Green (Style D only)

(Style C or D)

TE Thermocouple, K Type (0SPECIFICATIONS

X None

1999°F) (Style C or D)

F Input (Partial list)

AA AC Volts, scaled RMS, 200/600V

W1 Thermocouple, J,K,R,T; Selectable

°C/°F, 1°/0.1° (Style A)

Input Accuracy:

DCV, DCA ±(0.06% of reading + 2 counts)

AB AC Volts, scaled RMS,

200mV/2V/20V

W2 RTD, 100Ω Pt Selectable

3/4-wire, °C/°F, 1°/0.1°,

ACV, ACA

Temperature

±(0.07% of reading + 5 counts)

±(0.1% of reading + 3 counts)

G Power

385/392 (Style A)

Direct Pressure ±(1.0% of range + 3 counts)

AC AC mA, scaled RMS,

2/20/200mA

1 85-265VAC/95-370VDC

2 15-48VAC/10-72VDC

Frequency/RPM

Strain/Load

±(0.06% of reading + 2 counts)

±(0.08% of reading + 3 counts)

AD AC Amps, scaled RMS, 1 Amp

AE AC Amps, scaled RMS, 5 Amp

Process

Resistance/Pots

±(0.06% of reading + 2 counts)

±(0.06% of reading + 2 counts)

DE DC Volts, 2/20/200V/Custom

H Retransmit

w/Offset and 24V Excitation

DG DC Amps, 1A

A Isolated 16 Bit Current Output,

4-20mA

V Isolated 16 Bit Voltage Output,

0-10VDC

Bargraph Display: 4", 101 segment w/Offset and 24V Excitation

DF DC milliamp, 2/20/200mA

Bar Viewing Angle:

Digital Display:

Decimal Position:

±40° red or green, ±35° orange

4 digit LED, 0.31" (7.9mm) height

Range -1999 to 9999 counts

Front panel selectable n.nnn, nn.nn, nnn.n, nnnn.

DD DC Amps, 5A

E1 Line Frequency, 60-500VAC,

X None

I Relays

Relay Output:

199.9Hz, 400Hz optional

(Style C or D) for Type L:

2 Two 10A Form C

4 Two 10A Form C & Two 5A

Form A (SPST)

Form C (SPDT)

5A@250VAC, 5A@30VDC (resistive)

10A@240VAC, 8A@24VDC (resistive)

F2 Frequency,

99.99/999.9/9999Hz,

Form A **

Analog Output: Isolated 16 bit, user scalable

50mV-30V, w/24V Exc. (Style A)

X None mA out 4-20mA, 500Ω maximum loop resistance

F3 Frequency, for Type M:

Volts out 0-10VDC, 500Ω minimum load resistance

99.99/999.9/9999Hz,

B Two 10A Form C

Power Supply: 85-265 VAC / 95-370 VDC @2.5W (4.2W)

60-500VAC (Style A)

E Two 10A Form C & Two 5A

18-48 VAC / 10-72 VDC @ 2.5W (4.2W)

GF Direct Pressure, 15 psi differential Form A **

Sensor Excitation: 24V@50mA (2-wire loop power)

(clean, dry gas)

K Four 5A Form Al

10V@120mA (bridge excitation)

GH Direct Pressure, 30 psi X None

Operating Temperature: 0 to 60°C, 95% RH (non-condensing) differential (clean, dry gas)

** shared common between A & C

Click here for complete data & configuration information (pdf)

GK Direct Pressure, 100 psi differential (clean, dry gas)

12

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Weschler

Tri-Color Bargraph Meters

• Large, bright display with 16 step dimming

• 40 or 50 segment Tri-Color Bar

• Bar changes color at user adjustable setpoints —

Red, Green, Amber

• 5 digit resoluton

• Versatile selection of inputs

• Up to 4 form C relay outputs

• Peak/Valley option

• Trend indicator

• Analog retransmit option

• AC or DC power

• Rugged case

Sizes to replace popular edgewise and circular analog meters.

CONFIGURATION OPTIONS

SIZE

BG252

BH252

BV5A

BD101

BG241

BG281

6" Vertical BarGraph

6" Horizontal BarGraph

7 1

/

2

" Vertical BarGraph

10" Vertical BarGraph

4 1

/

2

" Square BarGraph

8" Circle BarGraph

POWER

120V AC 50/60Hz

240V AC 50/60Hz

12V DC

24V DC

28V DC

48V DC

125V DC

250V DC

120V AC / 125V DC

BG261TC

INPUT

DC Volts

DC Amps

AC Volts RMS

AC Amps RMS

Line Frequency

MAG Pickup

Thermocouple

RTD

Watts

VARs

Power Factor

50mV to 250V full scale

50µA to 5A full scale

50mV to 250V full scale

1mA to 5A full scale

4-20mA DC

1-5V DC

10-50mA DC

55-65 Hz

50Hz-20kHz

J, K or T

100 ohm Pt or 10 ohm Cu

Single & polyphase

Over 4000 combinations available - Contact

Weschler to configure a Tri-Color BarGraph for your application.

COMMUNICATION

RS232

RS485

RETRANSMIT

4-20mA

0-1mA

1-5V DC

0-1V DC

10-50mA DC

Excitation Power 24 VDC

@ 90mA

DIGITAL DISPLAY

COLOR

Green

Amber

Red

BD101TC

13

FIELD PROGRAMMABLE FUNCTIONS

• Zero and full scale point location

Setpoint type (Hi or Low)

• Hysteresis & latching

• Setpoint time delay

16 step dimming

• Digital display for engineering units

Enable/disable front buttons

I.D. selection for communication

• Bar form

Peak / Valley enable

Color zones

• Over / Under range, flashing

Lamp test

BH252TC

Click here for complete data & configuration information

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Weschler

Bargraph Meters

Large, bright display

101 segment bar, up to 10" high

3 1

/

2 or 4 1

/

2 digit resoluton

Versatile selection of inputs

Up to 4 form C relay outputs

Peak/Valley option

Analog retransmit option

AC or DC power

Rugged case

SIZE

BG252

BH252

PC101

PH101

PC202

PG202

BI1251

BW1316

BV5A

BD101

BG241

BG281

BG251

INPUT

DC Volts

DC Amps

AC Volts RMS

AC Amps RMS

Line Frequency

MAG Pickup

Thermocouple

RTD

Watts

VARs

Power Factor

CONFIGURATION OPTIONS

6" Vertical BarGraph

6" Horizontal BarGraph

DIN Size Vertical BarGraph

DIN Size Horizontal BarGraph

DIN Size Dual BarGraph

Dual BarGraph

6" Vertical BarGraph

6" Vertical BarGraph

7 1

/

2

" Vertical BarGraph

10" Vertical BarGraph

4 1

/

2

" Square BarGraph

POWER

120V AC 50/60Hz

240V AC 50/60Hz

5V DC

12V DC

24V DC

28V DC

48V DC

125V DC

250V DC

120V AC / 125V DC

8" Circle BarGraph

6" Circle BarGraph

SETPOINTS

Hi/Lo

Hi/Hi-Hi

Lo/Lo-Lo

Hi-Hi/Hi/Lo/Lo-Lo

50mV to 250V full scale

50µA to 5A full scale

50mV to 250V full scale

1mA to 5A full scale

4-20mA DC

1-5V DC

10-50mA DC

55-65 Hz

50Hz-20kHz

J, K or T

100 ohm Pt or 10 ohm Cu single & polyphase

COMMUNICATION

RS232

RS485

RETRANSMIT

4-20mA

0-1mA

1-5V DC

0-1V DC

10-50mA DC

Excitation Power 24 VDC

@ 90mA

LED COLOR

Green

Amber

Red

Over 4000 combinations available -

Contact Weschler to configure a

BarGraph for your application.

BG241

PC202

BG252

Click here for complete data & configuration information

14

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Dixson

Bargraph Meters/Controllers

15

• Fit Standard Switchboard Cutouts

• Red, Green or Amber LED Bar

• Precise 4 Digit Readout

• Underrange/Overrange Indication

• On/Off Control via Setpoint Relays

• Isolated Retransmit Option

• Transducer Excitation Supply

• Minimum 88,000 hour MTBF

• Two Year Warranty

SPECIFICATIONS

Input Ranges:

DC Volts

DC Current

AC Volts

AC Current

Thermocouple

RTD

DC Accuracy:

AC Accuracy:

Digital Display:

50mV to 250V

50mA to 250mA

250mV to 250V

1mA to 5A

J, K, T, E

Pt 100

±0.04% of span ±1d

±0.5% of span, above 5% of range

4 digit LED, 0.01% resolution

Enclosure:

Setpoint Relays:

Plastic, UL94 V0 or V1

Form C, 0.4A@125VAC, 2A@30VDC

Setability: 0.1%, with 1.0% hysteresis

Operating temperature: 0 to 60°C

Power: 115/230VAC, 50/60/400Hz, 4VA/channel

DC power available

Line Regulation:

BB101P, BB202P

±10%

Bar Segments: 101

Dimensions: 2.16"W x 6"H x 5.8"D

Panel Cutout: 1.77" x 5.7"

BW051P

BK051P

Orientation: Vertical or horizontal

Bar Segments: 51

Dimensions: 4.625" x 4.625" x 6.7"D

Panel Cutout: 4" dia ANSI switchboard

Bar Segments: 51

Dimensions: 3.82"W x 11.25"H x 7.10"D

Panel Cutout: 1.77" x 5.7"

BW051P

BK051P

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number

Order Example: BB101PVRYRHY1VAX-FS (0-150.0)

A B C D E F G H I J – K

L

M

A Basic Unit Basic Unit

BB BB101P CCBW BW051P

BC BB202P

(101 Segements each side)

CCBK BK051P

B Bargraph Orientation

H Horizontal (BP101P) V Vertical

C Bargraph Color

A Amber

G Green

D 4-Digit Display

X

A

None

Amber

R

S

G

R

Red (Standard)

Mixed

Green

(BW51/BK51 Only)

Red (Standard)

E Decimal Location

1

2

000.0

00.00

3

X

0.000

0000

F Setpoint Options (Must be ordered with Alarm Setpoint) (G)

X None A Amber

R Red G Green

G Alarm Setpoint (Must be ordered with Setpoint Option (F)

X

H

None

High/High

H Program Switches

L Low/Low

X None

I Primary Power

1

2

5

115 VAC

230 VAC

5 VDC

Y

4

6

8

Yes

24 VDC

12 VDC

48 VDC

J Signal Inputs

A

B

C

Amperes

Millivolts

T/C (Degrees C)

F T/C (Degrees F)

K Signal Type

A AC

L Special Options

D

X

M Scaling

None C

FS Factory Ranging (custom—specify scaling)

NOTE: Specify both sides for BB202P.

M Milliamperes

O Other

U Microamperes

V Volts

DC

Analog Retransmit

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Texmate

Intelligent Panel Meters

TIGER FAMILY

Intelligent Meter Controllers with Programmable Logic, Digital

Signal Processing Capabilities & Serial Communication

DI-50E

1/8 DIN 96X48mm

DI-60E

Tiger Family Features

• Intelligent and super-intelligent digital meters

• Front-panel digital calibration and function selection

• Built-in linearization function, 32 to 125 flexible points

• Built-in sensor excitation voltage 5 V /10 V / 24 V DC

• Six 5A relays or combinations of 10A relays and 5A relays

• Built-in memory for maximum and minimum readings

• Over 75 signal conditioners, single as well as dual inputs

• Two high-resolution, independently programmable 16-bit analog outputs

• Built-in timer and totalizer (signal integration) inputs, plus user-definable macros and real time clock

• Choice of serial communications – RS232, RS485, ASCII, Modbus and direct drive printer output

• Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC or

18-36 V AC / 9-60 V DC power supply

• Digital “smart” filtering

• Computer programmable

• Data logging up to 7000 samples

GI-50E

9/32 DIN 144x72mm

DI-60E

1/8 DIN 96X48mm

Leopard Family Features

LEOPARD FAMILY

Smart, Programmable Meter Relays with Isolated Retransmit or Control Loop Outputs

DL-40

1/8 DIN 96X48mm

DL-40 LR

• Smart 4-digit meters

• Front-panel digital scaling, offset, and setpoints

• Over 38 different signal conditioners

• Dual 10 and 5-amp relays, 4 relays total plus analog output

• 1/16 DIN meters have 2 or 3 relays or 1 relay plus analog output

• Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC, or 18-36 V AC / 9-60 V DC power supply

Lynx Family Features

BL-40

1/16 DIN 96X24mm

• Basic indicator 3.5 or 4.5 digit, 0.56” and 0.8” LED meters

• Analog scaling and offset from rear

• Over 24 single-input signal conditioners available

• Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC, or 18-36 V AC / 9-60 V DC power supply

SPECIFICATIONS

LYNX FAMILY

1/8 DIN

96X48mm

1/16 DIN

96X24mm

Tiger Meter Specifications

Configured for Direct Connection to Most Sensors and Process

Signals, with Displays Scalable to Any Unit of Measure

DX-35 LR

DX-40 LR

DX-35

DX-45

Accuracy: Built-in compensation and linearization functions enable system accuracies of the order of ±0.0001% of reading for analog inputs. Stop -

Start time resolution from ±1sec to ±0.7nsec. Digital input and pulse counts

±1 count.

A/D Convertors: A Dual Slope, bipolar 17 bit A/D is provided as standard on the main board. SMART modules have 24 bit or 16 bit Delta-Sigma A/D convertors that utilize the internal I

2

C BUS.

Temperature Coefficient: Typically 30ppm/˚C. Compensation can be utilized to achieve system temperature coefficients of 1ppm.

Warm Up Time: Up to 10 minutes, depending on input module.

Conversion Rate: Typically 10 samples per second. However, SMART input modules are available that can convert at 60, 240, 480 or 960 samples per second.

Control Output Rate: Can be selected for 100msec or 10msec.

Some SMART modules have SSR outputs that react within 1.2msec.

Excitation Voltage: Depends on input module selected. Typically, 5V, 10V or 24VDC is provided.

Operating Temperature: 0 to 50 ˚C (32 ˚F to 122 ˚F).

Storage Temperature: -20 ˚C to 70 ˚C (-4 ˚F to 158 ˚F).

Relative Humidity: <95% (non-condensing) at 40 ˚C (104 ˚F).

Case Options: NEMA 4X Lens cover

BX-35

BX-45

Metal case surround

Panel Adapters

16

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

17

Texmate

Intelligent Panel Meters

Leopard Meter Specifications

A/D Converter:

Accuracy:

Temperature Coefficient:

Warm Up Time:

Conversion Rate:

Operating Temperature:

Storage Temperature:

Lynx Meter Specifications

A/D Converter:

Accuracy:

Temperature Coefficient:

Warm Up Time:

Conversion Rate:

Operating Temperature:

Storage Temperature:

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: DI-50E-DR-PS1-IA01-IAC-S2-R1

Basic Unit A – B – C – D – E – F – G

TIGER FAMILY METER SELECTION

A

B

C

D

E

F

G

DI-50E

DI-60AE

DI-60E

GI-50E

Intelligent Modular, 32 pt Linear, Analog out & relays

Intelligent Modular, Alpha Numeric 6 digit 0.56” LED

Intelligent Modular, Numeric 6 digit 0.56” LED

Intelligent Modular, w/ 5 digit 1” LED

Display

DR

DG

DB

Red LED

Green LED

Super-bright Red LED

Power Supply

PS1

PS2

85-265VAC/95-370VDC

18-36VAC/9-60VDC

Input Modules – See Input Module List "T" Items

Output Options

AIC

AIV

Isolated 4 to 20 mA Analog Output

Isolated 0 to 10 VDC Analog Output

Serial Communications

S2

S4

S5

Relays

Isolated RS-232 communication + ASCII

Isolated RS-485 communication + ASCII

Isolated ModBus Compatible + ASCII

R1

R2

R6

R13

R14

Single 5A Form A Relay

Two 5A Form A Relays

Six 5A Form A Relays

Two 10A Form C Relays, One 5A Form A Relay

Two 10A Form C Relays, Two 5A Form A Relays

LEOPARD FAMILY METER SELECTION

A

B

C

D

E

F

14 bit single slope

±(0.05% of reading + 2 counts)

100 ppm/°C (Typical)

2 minutes

5 conversions per second (Typical)

0 to 60°C, <95% (non condensing)

–20°C to 70°C

12 bit dual slope

±(0.05% of reading + 2 counts)

100 ppm/°C (Typical)

2 minutes

3 conversions per second (Typical)

0 to 60°C, <95% (non condensing)

–20°C to 70°C

BL-40

BL-40H

DL-40

DL-40H

Display

4.0 digit, Modular, Low Profile, Half Height Case

4.0 digit, Thermocouple & RTD, Half Height Case

4.0 digit, Modular, 1/8 DIN case

4.0 digit, Thermocouple & RTD, 1/8 DIN Case

DR

DG

DB

LG

LR

Power Supply

Red LED, 0.56 inch high

Green LED, 0.56 inch high

Super bright LED, 0.56 inch high

Large Green LED, 0.8 or 1 inch high

Large Red LED, 0.8 or 1 inch high

PS1

PS2

85-265VAC/95-370VDC

18-36VAC/9-60VDC

Input Modules – See Input Module List "L" Items

Output Options

AIC

AIV

Isolated 4 to 20 mA Analog Output

Isolated 0 to 10VDC Analog Output

Relays

R1

R2

R3

R4

Single 10A Form A Relay

Two 10A Form A Relay

Two 10A Form A Relays, One 5A Form A Relay

Two 10A Form A Relays, Two 5A Form A Relays

LYNX FAMILY METER SELECTION

A

B

C

D

E

BX-35

BX-45

DX-35

DX-40

DX-45

3.5 Digit Universal Power Supply, 1/16 DIN Case

4.5 Digit Universal Power Supply, 1/16 DIN Case

3.5 Digit Universal Power Supply, 1/16 DIN Case

4 Digit Universal Power Supply, 1/16 DIN Case

4.5 Digit Universal Power Supply, 1/16 DIN Case

Display

DR

DG

DB

LG

LR

Red LED

Green LED

Super-bright Red LED

Large Green LED, 0.8 inch high

Large Red LED, 0.8 inch high

Power Supply

PS1

PS2

85-265VAC/95-370VDC

18-36VAC/9-60VDC

Input Modules – See Input Module List "LY" Items

Output Options

AIC

AIV

Isolated 4 to 20 mA Analog Output

Isolated 0 to 10VDC Analog Output

INPUT MODULE SELECTION

Function Module For

AC

AC 1A, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA04 . . . . . . . T,L,Ly

AC 5A, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA05 . . . . . . . T,L,Ly

AC 1A, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA09 . . . . . . . T,L,Ly

AC 5A, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA11 . . . . . . . T,L,Ly

AC 2/20/200mA, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA03 . . . . . . . T,L,Ly

AC 2/20/200mA, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA08 . . . . . . . T,L,Ly

AC 100mV, Scaled RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA10 . . . . . . . T,L,Ly

AC 100mV, True RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA12 . . . . . . . T,L,Ly

AC 200/600V, Scaled RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA01 . . . . . . . T,L,Ly

AC 200mV/2V/20V, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA02 . . . . . . . T,L,Ly

AC 200/600V, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA06 . . . . . . . T,L,Ly

AC 200mV/2V/20V, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA07 . . . . . . . T,L,Ly

DC

DC 5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID04. . . . . . . T,L,Ly

DC 1A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID09. . . . . . . T,L,Ly

DC 2/20/200mA w/ 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID03. . . . . . . T,L,Ly

DC 2/20/200mA w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . ID07. . . . . . . T,L,Ly

DC 20/50/100/200mV w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . ID02. . . . . . . T,L,Ly

DC 2/20/200V/Custom w/ 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . . . ID01. . . . . . . T,L,Ly

DC 2/20/200V/Custom w/ Ext. Decimal Select . . . . . . . . . . . . . . . . ID06 . . . . . . . . T

DC 2/20/200V/Custom w/ External LIN Table Select . . . . . . . . . . . ID08 . . . . . . . . T

DC 2/20/200V/Custom w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . ID05. . . . . . . T,L,Ly

DC Watts, 200V & 50mV from shunt . . . . . . . . . . . . . . . . . . . . . . . . . IW03 . . . . . . . . T

DC 2V and 3-wire RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT3. . . . . . . . . T

Dual DC 2mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD3 . . . . . . . . T

Dual DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD2 . . . . . . . . T

Dual DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD1 . . . . . . . . T

DC 50mV and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD6 . . . . . . . . T

DC 2V and 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD5 . . . . . . . . T

DC 2V and 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD4 . . . . . . . . T

DC 50mV and J K R S T B N Thermocouple . . . . . . . . . . . . . . . . . . . . . IDT5. . . . . . . . . T

DC 2V and J K R S T B N Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . IDT4. . . . . . . . . T

DC 1-5V Process w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . IP03 . . . . . . . T,L,Ly

DC 2/5/10/20V/2/20mA + 3 Digital Inputs. . . . . . . . . . . . . . . . . . . IP10. . . . . . . . . T

Triple DC 50mV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD2. . . . . . . . . T

Triple DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD1. . . . . . . . . T

DC 50mV and 50mV and J K R S T B N T/C. . . . . . . . . . . . . . . . . . . . . ITT6 . . . . . . . . . T

DC 50mV and 2V and J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . ITT9 . . . . . . . . . T

DC 2V and 2V and J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . ITT7 . . . . . . . . . T

DC 50mV and two J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . ITT5 . . . . . . . . . T

DC 2V and two J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITT3 . . . . . . . . . T

DC Volts and T/C and Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITTG . . . . . . . . . T

Quad DC 50mV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD2 . . . . . . . . T

Quad DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD1 . . . . . . . . T

RTD + DC V + DC V + Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQT5. . . . . . . . . T

Smart DC V, 16 bit, 1 to 800 Hz update rates . . . . . . . . . . . . . . . . . ISD1* . . . . . . . T

Smart DC V, 16 bit, 1 to 960 Hz update rates . . . . . . . . . . . . . . . . . ISD2** . . . . . . T

Smart DC V, 16 bit, 1 to 800 Hz w/dual SSRs . . . . . . . . . . . . . . . . . ISD3* . . . . . . . T

Smart DC V, 16 bit, 1 to 960 Hz w/dual SSRs . . . . . . . . . . . . . . . . . ISD4** . . . . . . T

Smart DC V, High Res & Acc, 24 bit 1-400Hz . . . . . . . . . . . . . . . . . . ISD5* . . . . . . . T

Smart DC V, High Res & Acc, 24 bit 1-480Hz . . . . . . . . . . . . . . . . . . ISD6** . . . . . . T

Smart DC V, High Res & Acc, 1-400Hz w/dual SSRs . . . . . . . . . . . . ISD7* . . . . . . . T

Smart DC V, High Res & Acc, 1-400Hz w/dual SSRs . . . . . . . . . . . . ISD8** . . . . . . T

Smart Dual 3-wire Potentiometer (50 Hz) . . . . . . . . . . . . . . . . . . . . . ISR3* . . . . . . . T

Smart Dual 3-wire Potentiometer (60 Hz) . . . . . . . . . . . . . . . . . . . . . ISR4** . . . . . . T

Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . . . . . . . . . . . . . . . . ISDA* . . . . . . . T

Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . . . . . . . . . . . . . . . . ISDB** . . . . . . T

Smart Load Cell and RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISSB. . . . . . . . . T

DC Process 2/5/10/20/200V/2/20mA w/ 24V Exc.. . . . . . . . . . . . IP07 . . . . . . . . T,L

DC Process 2/5/10/20/200V/2/20mA w/ 24V Exc & AutoCal . . . IP08. . . . . . . . . T

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Texmate

Intelligent Panel Meters

INPUT MODULE SELECTION - CONTINUED

Function Module For

COUNTER

Quadrature Counter . . . . . . . . . . . . . . . . . . . . . . . . IC02 . . . T

Quadrature Counter w/dual SSRs. . . . . . . . . . . . . IC03 . . . T

Universal Freq./ RPM / Up Down Counter . . . . . . IF10 . . . T

Dual UP/DOWN Counter. . . . . . . . . . . . . . . . . . . . . IDC1 . . . T

Counter and T/C and 4-20mA . . . . . . . . . . . . . . . . ITTF . . . T

Smart Dual Counter and Pressure Direct . . . . . . . ISP1 . . . T

DUAL INPUTS

3-wire RTD and DC V . . . . . . . . . . . . . . . . . . . . . . . IDT3 . . . T

3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T

Dual DC 2mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD3. . . T

Dual DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD2. . . T

DC 50mV and 4-20mA . . . . . . . . . . . . . . . . . . . . . . IDD6. . . T

DC 2V and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . IDD5. . . T

DC 2V and DC 50mV . . . . . . . . . . . . . . . . . . . . . . . IDD4. . . T

Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T

Dual DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD1. . . T

Dual Direct Pressure (Abs. or Differential/Gage). . . IGYY . . . T

Dual Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDF2 . . . T

Dual Pressure Input . . . . . . . . . . . . . . . . . . . . . . . . IDS2 . . . T

Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T

Dual Resistance Input . . . . . . . . . . . . . . . . . . . . . . IDR1. . . T

Dual RTD Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT2 . . . T

Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS5* . . T

Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS6** . T

Dual Strain Gage Input. . . . . . . . . . . . . . . . . . . . . . IDS1 . . . T

Dual Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . IDT1 . . . T

Thermocouple and 4-20mA . . . . . . . . . . . . . . . . . . IDP3 . . . T

Thermocouple and DC mV . . . . . . . . . . . . . . . . . . . IDT5 . . . T

Thermocouple and DC V . . . . . . . . . . . . . . . . . . . . IDT4 . . . T

Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T

Dual UP/DOWN Counter. . . . . . . . . . . . . . . . . . . . . IDC1 . . . T

Smart Dual 3-wire Potentiometer . . . . . . . . . . . . . ISR3 . . . T

Smart Load Cell and Process (4-20mA) . . . . . . . . . ISS9 . . . T

Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . ISDA* . . T

Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . ISD8**. T

Smart Dual Photo Diode Input. . . . . . . . . . . . . . . . ISSE . . . T

Smart Dual RTD (50Hz) . . . . . . . . . . . . . . . . . . . . . IST5* . . T

Smart Dual RTD (60Hz) . . . . . . . . . . . . . . . . . . . . . IST6** . T

4 - 20mA

3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T

DC 50mV and 4-20mA . . . . . . . . . . . . . . . . . . . . . . IDD6. . . T

DC 2V and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . IDD5. . . T

Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T

Thermocouple and 4-20mA . . . . . . . . . . . . . . . . . . IDP3 . . . T

Process Loop 4-20mA . . . . . . . . . . . . . . . . . . . . . . IP01 . T,L,Ly

Process Loop 4-20mA w/ Ext. Lin Table . . . . . . . IP09 . T,L,Ly

Process Loop 4-20mA w/ 24V Exc. & AutoCal . . IP06 . . . T

Process Loop 4-20mA w/ 24V Exc. . . . . . . . . . . . IP02 . T,L,Ly

Quad 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQP1 . . . T

Smart Load Cell and Process 4-20mA . . . . . . . . . . ISS9 . . . T

Triple 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITP1 . . . T

4-20mA and 4-20mA and T/C . . . . . . . . . . . . . . . . ITT8 . . . T

T/C and 4-20mA and Counter . . . . . . . . . . . . . . . . ITTF . . . T

T/C and 4-20mA and DC mV . . . . . . . . . . . . . . . . . ITTA . . . T

T/C and 4-20mA and DC Volts . . . . . . . . . . . . . . . ITTB . . . T

T/C and 4-20mA and Frequency . . . . . . . . . . . . . . ITTF . . . T

T/C and T/C and 4-20mA . . . . . . . . . . . . . . . . . . . ITT4 . . . T

FREQUENCY / RPM

Universal Freq./ RPM / Up Down Counter . . . . . . IF10 . . . T

Universal Frequency / RPM . . . . . . . . . . . . . . . . . . IF05 . . . L

Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF08 . . . L

Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF06 . . . T

Dual Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDF2 . . . T

Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T

RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T

T/C and 4-20mA and Frequency . . . . . . . . . . . . . . ITTF . . . T

T/C and DC Volts and Frequency. . . . . . . . . . . . . . ITTG . . . T

RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T

LVDT

Smart Dual LVDT (50 Hz) . . . . . . . . . . . . . . . . . . . . ISL1* . . T

Smart Dual LVDT (60 Hz) . . . . . . . . . . . . . . . . . . . . ISL2** . T

OXIDATION REDUCTION POTENTIAL

Oxidation Reduction Potential (ORP). . . . . . . . . . . IOR1. . . T pH pH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IH01 . . . T pH w/ Automatic Temperature Compensation . . . IH02 . . . T

Function Module For

POTENTIOMETER

3-wire Potentiometer 1kΩ min. . . . . . . . . . . . . . . . IR02 . T,L,Ly

Linear Potentiometer 1kΩ min . . . . . . . . . . . . . . . IR03 . . T,L

Smart Dual 3-wire Potentiometer (50 Hz). . . . . . . ISR3* . . T

Smart Dual 3-wire Potentiometer (60 Hz). . . . . . . ISR4**. T

Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T

Smart Single 3-wire Potentiometer (50 Hz) . . . . . ISR1* . . T

Smart Single 3-wire Potentiometer (60 Hz) . . . . . ISR2**. T

PRESSURE / LOAD CELL

Universal Direct Pressure . . . . . . . . . . . . . . . . . . . . IGYZ . T,L,Ly

Direct Pressure with 2 Digital Inputs . . . . . . . . . . IGYX . . . T

Dual Direct Pressure (Abs. or Differential/Gage) . IGYY . . . T

Dual Pressure Input . . . . . . . . . . . . . . . . . . . . . . . . IDS2 . . . T

Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS5* . . T

Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS6** . T

Pressure/Load Cell 20/2mV/V, 5/10V

Exc, 4-wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IS05 . T,L,Ly

Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire. . IS06 . T,L,Ly

Pressure/Load Cell Ext Exc., High Impedance . . . IS07 . . T,L

Pressure/Load Cell Ext Exc., 4/6-wire. . . . . . . . . . IS04 . . T,L

Pressure/Load Cell w/ AutoCal, 4-wire . . . . . . . . . IS03 . . . T

Pressure/Load Cell, 4/6-wire. . . . . . . . . . . . . . . . . IS02 . . T,L

Smart Pressure/Load Cell, Standard Res 16 bit . ISS1* . . T

Smart Pressure/Load Cell, Standard Res 16 bit . ISS2** . T

Smart Pressure/Load Cell, High Res & Acc 24 bit . ISS3* . . T

Smart Pressure/Load Cell, High Res & Acc 24 bit . ISS4** . T

Smart Quad Pressure/Load Cell (50 Hz) . . . . . . . ISS7* . . T

Smart Quad Pressure/Load Cell (60 Hz) . . . . . . . ISS8** . T

Smart Pressure Direct & Dual Counter. . . . . . . . . . ISP1 . . . T

Smart Load Cell and Process 4-20mA . . . . . . . . . . ISS9 . . . T

Smart Load Cell and RTD. . . . . . . . . . . . . . . . . . . . ISSB . . . T

Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSC* . . T

Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSD**. T

Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T

PROCESS LOOP

Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T

Process Loop 4-20mA . . . . . . . . . . . . . . . . . . . . . . IP01 . T,L,Ly

Process Loop 4-20mA w/ Ext. Lin Table . . . . . . . . . . IP09 . . . T

Process Loop 4-20mA w/ 24V Exc. & AutoCal. . . . . . IP06 . . . T

Process Loop 4-20mA w/ 24V DC Exc. . . . . . . . . IP02 . T,L,Ly

QUAD INPUTS

Quad 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQP1 . . . T

Quad DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD2. . . T

Quad DC 2V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD1. . . T

Quad RTD Platinum 2 wire connection. . . . . . . . . IQT2 . . . T

Quad RTD Platinum 4 wire connection. . . . . . . . . IQT4 . . . T

RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T

Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T

Smart Quad Pressure/Load Cell (50 Hz) . . . . . . . ISS7* . . T

Smart Quad Pressure/Load Cell (60 Hz) . . . . . . . ISS8** . T

Smart Quad Thermocouple (50 Hz) . . . . . . . . . . . IST3* . . T

Smart Quad Thermocouple (60 Hz) . . . . . . . . . . . IST4** . T

RESISTANCE

Dual Resistance 0.2/2/20kΩ . . . . . . . . . . . . . . . . IDR1. . . T

Resistance 200/2k/20kΩ, 2/3/4-Wire . . . . . . . . IR01 . . . T

Resistance 2kΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . IR04 . . . L

Resistance 2kΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . IR05 . . Ly

Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T

Smart Voltage and Resistance . . . . . . . . . . . . . . . ISD9 . . . T

RTD

3-wire RTD and DC V . . . . . . . . . . . . . . . . . . . . . . . IDT3 . . . T

3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T

Dual RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT2 . . . T

Quad RTD Platinum 2 wire. . . . . . . . . . . . . . . . . . . IQT2 . . . T

Quad RTD Platinum 4 wire. . . . . . . . . . . . . . . . . . . IQT4 . . . T

RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T

RTD, 10Ω Copper 2/3/4-wire . . . . . . . . . . . . . . . . IT13 . . . T

RTD, 100Ω Pt. 2/3/4-wire . . . . . . . . . . . . . . . . . . . IT02 . . . T

RTD, 100Ω Pt. 2/3/4-wire (-199.9 to 199.9˚C). . IT14 . T,L,Ly

RTD, 100Ω Pt. 2/3/4-wire (-199.9 to 199.9°F). . IT05 . T,L,Ly

RTD, 100Ω Pt. 2/3/4-wire (-200 to 800°C) . . . . . IT03 . T,L,Ly

RTD, 100Ω Pt. 2/3/4-wire (-200 to 1470°F) . . . . IT04 . T,L,Ly

RTD, 100Ω Pt. 3/4-wire, °C/°F, 1°/0.1°. . . . . . . IT11 . . . L

RTD, 120Ω Nickel 2/3/4-wire . . . . . . . . . . . . . . . . IT12 . . . T

RTD, 1000Ω Pt. Select 3/4-wire, °C/°F, 1°/0.1° . IT15 . . . L

Smart Load Cell and RTD. . . . . . . . . . . . . . . . . . . . ISSB . . . T

Smart Dual RTD (50Hz) . . . . . . . . . . . . . . . . . . . . . IST5* . . T

Smart Dual RTD (60Hz) . . . . . . . . . . . . . . . . . . . . . IST6** . T

Smart 6 Input - 3 RTD, 2 Process, 1 Digital . . . . . IST1* . . T

Smart 6 Input - 3 RTD, 2 Process, 1 Digital . . . . . IST2** . T

Triple RTD Platinum 100Ω, 4-wire . . . . . . . . . . . . . ITTC . . . T

Function Module For

Triple RTD Platinum 100Ω, 2-wire . . . . . . . . . . . . . ITT2 . . . T

RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T

SINGLE PHASE POWER

Single Phase Power, 300V/1A. . . . . . . . . . . . . . . . IW01 . . T

Single Phase Power, 300V/5A. . . . . . . . . . . . . . . . IW02 . . T

Single Phase Power, 600V/1A. . . . . . . . . . . . . . . . IW04 . . T

Single Phase Power, 600V/5A. . . . . . . . . . . . . . . . IW05 . . T

STRAIN GAGE

Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T

Dual Strain Gage. . . . . . . . . . . . . . . . . . . . . . . . . . . IDS1 . . . T

Strain Gage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IS01 . . T,L

THERMOCOUPLE

Dual Thermocouple J K R S T B N . . . . . . . . . . . . . . IDT1 . . . T

T/C J K R S T B N and 4-20mA. . . . . . . . . . . . . . . . . IDP3 . . . T

T/C J K R S T B N and DC 50mV . . . . . . . . . . . . . . . IDT5 . . . T

T/C J K R S T B N and DC 2V . . . . . . . . . . . . . . . . . . IDT4 . . . T

Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T

Smart Quad Thermocouple (50 Hz) . . . . . . . . . . . IST3* . . T

Smart Quad Thermocouple (60 Hz) . . . . . . . . . . . IST4** . T

Thermocouple J K R S T B N . . . . . . . . . . . . . . . . . . . IT01 . . . T

T/C, J K R T, Selectable°C/°F, 1°/0.1° . . . . . . . . IT10 . . . L

T/C J K R S T B N , 4-20mA and 4-20mA . . . . . . . . . ITT8 . . . T

T/C J K R S T B N , 4-20mA and Counter. . . . . . . . . . ITTF . . . T

T/C J K R S T B N , 4-20mA and DC 50mV. . . . . . . . ITTA . . . T

T/C J K R S T B N , 4-20mA and DC 2V. . . . . . . . . . . ITTB . . . T

T/C J K R S T B N , DC 50mV and DC 50mV . . . . . . ITT6 . . . T

T/C J K R S T B N , DC 2V and DC 50mV . . . . . . . . . ITT9 . . . T

T/C J K R S T B N , DC 2V and DC 2V . . . . . . . . . . . . ITT7 . . . T

T/C J K R S T B N , T/C and 4-20mA . . . . . . . . . . . . . ITT4 . . . T

T/C J K R S T B N , T/C and DC 50mV . . . . . . . . . . . ITT5 . . . T

T/C J K R S T B N , T/C and DC 2V . . . . . . . . . . . . . . ITT3 . . . T

T/C, 4-20mA and Frequency . . . . . . . . . . . . . . . . . ITTF . . . T

T/C, DC Volts and Frequency . . . . . . . . . . . . . . . . . ITTG . . . T

Triple Thermocouple J K R S T B N . . . . . . . . . . . . . ITT1 . . . T

TRIPLE INPUTS

Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSC* . . T

Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSD**. T

Smart Pressure Direct & Dual Counter . . . . . . . . . . ISP1 . . . T

Triple 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITP1 . . . T

Triple DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD2 . . . T

Triple DC 2V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD1 . . . T

Triple RTD Platinum 100Ω, 4-wire . . . . . . . . . . . . . ITTC . . . T

Triple RTD Platinum 100Ω, 2-wire . . . . . . . . . . . . . ITT2 . . . T

RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T

T/C J K R S T B N , 4-20mA and 4-20mA . . . . . . . . . ITT8 . . . T

T/C J K R S T B N , 4-20mA and Counter. . . . . . . . . . ITTF . . . T

T/C J K R S T B N , 4-20mA and DC 50mV. . . . . . . . ITTA . . . T

T/C J K R S T B N , 4-20mA and DC 2V. . . . . . . . . . . ITTB . . . T

T/C J K R S T B N , DC 50mV and DC 50mV . . . . . . ITT6 . . . T

T/C J K R S T B N , DC 2V and DC 50mV . . . . . . . . . ITT9 . . . T

T/C J K R S T B N , DC 2V and DC 2V . . . . . . . . . . . . ITT7 . . . T

T/C J K R S T B N , T/C and 4-20mA . . . . . . . . . . . . . ITT4 . . . T

T/C J K R S T B N , T/C and DC 50mV . . . . . . . . . . . ITT5 . . . T

T/C J K R S T B N , T/C and DC 2V . . . . . . . . . . . . . . ITT3 . . . T

T/C, 4-20mA and Frequency . . . . . . . . . . . . . . . . . ITTF . . . T

T/C, Volts and Frequency . . . . . . . . . . . . . . . . . . . . ITTG . . . T

Triple Thermocouple J K R S T B N . . . . . . . . . . . . . ITT1 . . . T

*Optimized for 50 Hz rejection. **Optimized for 60 Hz rejection.

ENHANCED TIGER FAMILY MODELS

DI-503

Triple Display

Meters

DI-602A

Dual Display Meters

Digital

Meter with

Annunciators

DI-50/AN6

DI-802X

Dual Line Alphanumeric LCD

18

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

19

WESCHLER INSTRUMENTS

Texmate

Application-Specific Meters and Controllers

DU-SERIES 1/8 DIN (96 x 48mm) METERS

Standard user selectable 100/120 VAC or 200/240 VAC power supply, option 24 VAC, or auto sensing isolated AC/DC 9 to 24 VAC,

12 to 36 VDC. 0.56" std. red or optional green or super bright red

LED display.

AC Current

DU-35ACI

........

AC Amperes, Average, 1A and 5A (built-in shunt)

DU-35ACIRMSAC Amperes, True RMS 1A and 5A (built-in shunt)

DU-40ACI

........

4-Digit Version of the DU-35ACI

AC Voltage

DU-35AC

........

AC Volts, Average, 199.9/700.0 VAC

DU-35ACRMSAC Volts, True RMS 199.9V/700V

DU-40AC

........

AC Volts, Average, 700.0 VAC, 4-Digit

AC Line Frequency

DU-35HZ

..........

Line Frequency 199.9 or 500 Hz up to 700V AC input w/3.5-Digit

DC Voltage

DU-35

............

DC Volts Selectable from 2V/20V/200V, 3.5-Digit

DU-35MV

........

DC mV Selectable 50 mV/100 mV/200 mV, 3.5-Digit

DU-45

............

DC Volts Selectable from 2 V/20V/200V, 4.5-Digit

DU-45MV

........

DC mV Selectable 50 mV/100 mV/200 mV 4.5-Digit

Process 4 to 20 mA

DU-35CL

DU-35CLE

DU-45CL

........

Process 4 to 20 mA, 3.5-Digit

........

Process 4 to 20 mA with 24 VDC Excitation, 3.5-Digit

........

Process 4 to 20 mA, 4.5-Digit

Pressure

DU-35P

............

Strain Gauge, Load Cell, and Pressure, 4- and 6-Wire,

5 VDC Excitation, Selectable Sensitivity from 2 mV to 20 mV/V, 3.5-Digit, 0.56" LED Display

Temperature

DU-35J

DU-35K

..........

Thermocouple J or K, °C or °F, 3.5-Digit, 0.56" LED

..........

Thermocouple J or K, °C or °F, 3.5-Digit, 0.56" LED

DU-35RTD

......

100Ω Platinum RTD, 2-, 3-, or 4-Wire, °C or °F, 3.5-Digit

Metal Case Option for 96 x 48mm DIN Case

OP-MTL96X48 Provides Extra Strength and Protection Against Fire

OP-MTLCLIP Mounting clips

SD-SERIES 1/8 DIN (96 x 48 mm) ULTRA SHORT-DEPTH

Only 1.2" depth behind panel, including connectors.

DC Voltage

SD-35

............

3.5-Digit, 0.56" standard red LEDs (optional green or super bright red). 2/20/200/Custom DCV ranges, 5VDC power.

Pin compatible with Asahi AP-501.

4-20mA Loop Powered

SD-50X

..........

5-Digit 0.5" LCD. 3.5-27.5mA input span, -19999 to 30000 count display. 6th digit displays F, C, inactive 0 or blank.

AM-SERIES 1/16 DIN (96 x 24 mm) SHORT-DEPTH BARGRAPHS

5 VDC power supply. 30 segment standard red or optional green or amber LED display.

Selectable Process 4 to 20 mA or DC Voltage

AM-30

............

6 Header Selectable DC Ranges Plus 4 to 20 mA

AM-30R1

AM-30R2

........

6 DC + 4 to 20 mA w/One 2A/120 VAC Relay

........

6 DC + 4 to 20 mA w/Two 2A/120 VAC Relays

BN-SERIES 1/16 DIN (96 x 24 mm) SHORT-DEPTH METERS

Standard 24 VDC isolated power supply, option 12V or 15 V. 0.56" std. red or optn. green or super bright red LED display.

Process 4 to 20 mA

BN-35CL

........

Process 4 to 20 mA, 3.5-Digit

DC Voltage

BN-35I

..........

DC Volts Selectable from 2V/20V/200V, 3.5-Digit

BN-45I

..........

DC Volts Selectable from 2V/20V/200V, 4.5-Digit

Meters below, 5 VDC power supply. 0.56" standard red or optional green or super bright red LED display.

BN-35

BN-45

............

DC Volts Selectable from 2V/20V/200V, 3.5-Digit

............

DC Volts Selectable from 2V/20V/200V, 4.5-Digit

BCD Remote Display

BN-35BCD

BN-40BCD

......

Remote BCD Display 3.5-Digit

......

Remote BCD Display 4-Digit

Meter below, AC/DC auto sensing isolated power supply

85 to 256 VAC/90 to 380 VDC power supply. 0.3" standard red or optional green or super bright red LED display.

Dual AC Volts and Hertz, Signal Powered

DD-40VHZ

........

3.5-Digit, 0.3" LED Display

MU-SERIES 1/32 DIN (48 x 24 mm) METERS

AC/DC auto sensing isolated power supply 12 to 24 VAC/9 to

36 VDC power supply. 0.3" standard red or optional green or super bright red LED display.

MU-35

............

DC Volts Selectable from 2V/20V/200V

MU-35MV

..........

DC mV Selectable from 50 mV/100 mV/200 mV

MU-35CL

..........

Process 4 to 20 mA

UM-SERIES—NEMA CASE LOW-COST UTILITY METERS

Optional 0.8" display

Standard user selectable 100/120 VAC or 200/240V AC power supply, optn. 24 VAC, or auto sensing isolated AC/DC 9 to 24 VAC, 12 to 36 VDC.

0.56" std. red or optn. 0.8" std. red (3.5-digit and UM-40AC only) or green or super bright red LED display.

AC Current

UM-35ACI

........

AC Amps, Average, 1A or 5A, 3.5-Digit Display

AC Voltage

UM-35AC

UM-40AC

........

700 VAC and 199.9 VAC Full Scale, 3.5-Digit Display

........

700.0 VAC FS, 0.1V Resolution, 4-Digit Display

AC Line Frequency

UM-35HZ

........

40 Hz to 199.9 Hz or 40 Hz to 500 Hz, 3.5-Digit

DC Voltage

UM-35

............

±2/20 VDC or Optionally ±2/200 VDC, 3.5-Digit

UM-35MV

........

±50 mV and ±00 mV Inputs to Suit External DC

Current Shunts, 3.5-Digit

UM-45

............

±2/20 VDC or Optionally ±2/200 VDC, 4.5-Digit

UM-45MV

........

±50 mV, ±100 mV, or ±200 mV Inputs to Suit

Standard DC Current Shunts, 4.5-Digit

Process 4 to 20 mA

UM-35CL

........

1.4V Loop Drop, Scalable in Engineering Units from

-1999 to +1999, 3.5-Digit

UM-35CLE

UM-45CL

......

Built-In 24 VDC Loop Excitation

........

4.5-Digit Version of UM-35CL as Above

Pressure

UM-35P

..........

For Pressure Transducers with 2 mV/V to 20 mV/V

Outputs with 5 VDC Exc., 3.5-Digit

Thermocouple, 3.5-Digit

UM-35J

UM-35K

..........

Designed for J Thermocouple Input, 1° Resolution

..........

Designed for K Thermocouple Input, 1° Resolution

UM-35RTD

......

3-Wire, 100-Ohm RTD, 0.1° or 1° Resolution

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Texmate

Application-Specific Meters and Controllers

MINI-METER DVM-5 SERIES, 1.378 x 0.5 x 1.375" CASE

Loop-Powered, Process 4 to 20 mA

DVM-5/CL

............

3.5-Digits, 0.276" LED Display

Volt and RTD, 5 VDC Power

DVM-5

................

200 mV to 200 VDC, 0.276" LED Display

DVM-5/RTD

..........

RTD Sensor Input, 0.276" LED Display

SM SERIES 3-WIRE DC INPUT

20 mV to 2 VDC, 3.5-Digit LED/LCD, 5 VDC Power

SM-35

............

2 to 20 VDC, 0.56" LED, Display Hold

SM-35X

............

2 to 20 VDC, 0.48" LCD, Display Hold

SM-35MV

..........

20 mV to 2 VDC LED Constant Current 5 VDC

Power Supply Eliminates Ground Loop Problems

SM-35XMV

........

20 mV to 2 VDC LCD Constant Current 5 VDC

Power Supply Eliminates Ground Loop Problems

LOOP POWERED LED BARGRAPH

1/16 DIN 96x24mm, 31 segment red or green LEDs. Only 4V loop drop,

3" behind panel.

SB-B31 ..................4-20mA Loop Powered Bargraph

SLIM-BEZEL CASE LED AND LCD MINIATURE METERS

Loop-Powered, Process 4 to 20 mA, 0.48" LCD

CM-35XTL

............

Less than 1 VDC Loop Drop and 1 Joule Energy

CM-35XT

Storage. Fully Scalable

............

Economical Standard 6.5V Loop Drop

DC and AC 2-Wire Signal-Powered, 0.48" LCD

SP-35X

..............

±3.5 VDC to 199.9 VDC

SP-35XRMS

SP-35XMV

........

AC or DC 15.0V to 199.9V and 15.0V to 250V

..........

50 mV shunt/10 to 100 VDC Power

Low Cost DC Bargraph, 5 VDC Power

AM-20

..............

20 Segment, 200 mV to 200 VDC, 5 VDC Power

DC Volts, 4.5 Digit LED/LCD, 5 VDC Power

PM-45X/45XU

PM-45L

........

200 mV to 1200V BCD Output Option

..............

200 mV to 1200 VDC and BCD Output Option

CP-45

................

BCD Comparator Form C Relay 5 VDC Power

J and K Thermocouple Meters LED/LCD

TM-35J

TM-35K

TM-35XJ

..............

Differential Input Configuration Allows Several

................

Meters to be Operated with Grounded Thermocouples

................

from the Same 5 VDC Power Supply. Select °C or °F.

TM-35XK

RP AND PM SERIES METERS

DC Input, 110/230 VAC Power

RP-35U

............

Economy DC inputs, 3.5-Digit, 0.56" LED Display

RP-35A

............

Precision Differential DC Input, 3.5-Digit, 0.56" LED

RP-35AR

..........

Auto Dual Ranging, 3.5-Digit, 0.56" LED Display

RP-3500

..........

Single Ended Input 3.5-Digit, 0.56" LED Display

RP-3500D2

......

3.5-Digit Differential Input with Optional BCD

RP-4500

..........

Single Ended Input 4.5-Digit, 0.56" LED Display

RP-4500D2

......

4.5-Digit Differential Input with Optional BCD

DC Input, 5 VDC Power

PM-35U

PM-35A

PM-35AR

PM-35X

..........

Low Cost, 3.5-Digit, 0.3" LED Display

..........

Differential Inputs, 3.5-Digit, 0.56" LED Display

..........

Auto Range, 3.5-Digit, 0.56" LED Display

..........

Low Power, 3.5-Digit, 0.48" LCD Display

PM-35XAC110

..........

DC Input 110/220 VAC Power, 0.48" LCD Display

PM-45

............

Single Ended 4.5-Digit, 0.3" LED Display

Basic Unit

AM-20

AM-30

AM-30R1

AM-30R2

BN-35

BN-35BCD

BN-35CL

BN-35I

BN-40BCD

BN-45

BN-45I

CM-35XT

CM-35XTL

CN-PUSH/XX

CP-45

DD-40VHZ

DU-35

DU-35AC

$ 85

$ 119

DU-35ACI1 $ 125

DU-35ACI1RMS $ 145

DU-35ACI5 $ 125

DU-35ACI5RMS $ 145

DU-35ACRMS

DU-35CL

$ 139

$ 105

$ 119

$ 129

$ 119

$ 119

$ 99

$ 159

$ 55

$ 109

$ 139

$ 169

$ 99

$ 149

$ 139

$ 129

$ 169

$ 119

$ 149

$ 86

$ 110

$ 18

$ 95

$ 160

DU-35CLE

DU-35HZ

DU-35J

DU-35K

DU-35MV

DU-35P

DU-35RTD

DU-40AC

$ 119

$ 159

DU-40ACI1 or 5 $ 169

DU-45 $ 149

$ 159

$ 155

$ 79

DU-45CL

DU-45MV

DVM-5

DVM-5/4-20

DVM-5/CL

DVM-5/G

DVM-5/MV

DVM-5/RTD

MU-35

MU-35MV

MU-35CL

OP-MTL96X48

OP-MTLCLIP

$ 99

$ 109

$ 84

$ 79

$ 109

$ 99

$ 109

$ 119

$ 10

$ 6

OP-N4X/96X48 $ 20

PM-35A

PM-35AR

PM-35U

PM-35X

PM-35XAC

PM-45

RP-35A

RP-35AR

RP-35U

RP-3500

$ 65

$ 92

$ 39

$ 79

$ 94

$ 85

$ 79

$ 110

$ 69

$ 105

ORDERING INFORMATION

Basic Unit

RP-3500D2

RP-4500

RP-4500D2

SB-B31

SD-35

SD-50X

SM-35

SM-35MV

SM-35X

SM-35XMV

SP-35X

SP-35XRMS

SP-35XMV

TM-35J

TM-35K

TM-35XJ

TM-35XK

UM-35

UM-35AC

UM-35ACI1 or 5

UM-35CL

UM-35CLE

UM-35HZ

UM-35J

UM-35K

UM-35MV

UM-35P

UM-35RTD

UM-40AC

UM-45

UM-45CL

UM-45MV

OPTIONS

Display Options

BRIGHT

GREEN

LARGE/GREEN

LARGE/RED

Power Supply

V0-24V

V0-50K

V0-DC/ISO

Input Range

CB-FS35

CB-FS45

HD-CHANGE

Connectors

CN-L10

CN-L15

CN-PUSH/BN

Special Options

OP-MTL96X48

OP-N4SEAL/UM

OP-N4X/96X48

SCREW TERMINAL OPTIONS

FOR UM AND SM SERIES

AC ADAPTERS (120V)

PS-2405 Regulated

[email protected]

PS-520 Regulated

[email protected]

$ 135

$ 125

$ 165

TB-KIT

..........

Individual Screw Terminal

Blocks are Included with all

UM and SM Meter Orders

CN-PUSH/XX ....Ten Position Screw Terminal

Assemblies, Pre-configured for Texmate Meters w/Gold

Fingered PCB Inputs

$ 89

$ 99

$ 95

$ 95

$ 75

$ 139

$ 95

$ 109

$ 129

$ 144

$ 135

$ 59

$ 49

$ 69

$ 59

$ 79

$ 89

$ 105

$ 99

$ 94

$ 94

$ 104

$ 104

$ 64

$ 79

$ 85

$ 72

20

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Newport

Panel Meters/Controllers

INFCAC Series

• 4-Digit, 14-Segment LED Display, Red or Green

• High ±0.1% of Reading Accuracy

• Wide Selection of AC Current and Voltage Ranges

• Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Pending)

• Front Panel Configuration

• Available with Dual 6 Amp Relays and/or Analog Output

INFCAC

INFC Series

• Process (DC Voltage and Current), Strain Gauge,

Thermocouple, and RTD

• Dual Differential Thermocouple and RTD

• pH ORP

• Relay Output Optional

• Isolated or Non-Isolated Analog Output Optional

IDP-0

IDP Series

• Easy Scaling

• 4-Digit LED Display

• Max or Min Recall

• Short Case 4.1" (104 mm)

• Red or Green LED Display

• Power 115 VAC, 230 VAC or 10–32 VDC

21

INFC ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: INFCP-5-1-2

A – B – C – D

A

B

C

D

Basic Unit

INFCP Process (DC Voltage and Current)

INFCS Strain Input

NIFCT Thermocouple

INFCDT Dual/Differential Thermocouple

INFCR RTD

INFCDR Dual/Differential RTD

INFCPH pH

INFCOR ORP

INFCOP pH/ORP

Power and Display

0

1

115 VAC, Red LED Display

230 VAC, Red LED Display

4

5

6

7

2

3

115 VAC, Green LED Display

230 VAC, Green LED Display

10–32 VDC, Red LED Display

10–32 VDC, Green LED Display

25–56 VDC, Red LED Display

25–56 VDC, Green LED Display

0

1

2

Relays

0

1

None

Two 6 Amp Form C Relays

Analog Output

None

Non-Isolated Analog

Isolated Analog Output

N/C

N/C

$ 70

N/C

$ 80

$ 90

INFCAC ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: INFCAC-0-0-1-0-V5

A – B – C – D – E – F

D

0

0

1

1

E

0

1

2

F

V5

C5

1

2

3

C

B

0

A

INFCAC

Basic Unit

AC Voltage and Current Controller

Power and LED Color

115 VAC, Red LED Display

230 VAC, Red LED Display

115 VAC, Green LED Display

230 VAC, Green LED Display

Control Output

No Control Output

Two 6A Form “C” Relays $

Analog Output

No Analog Output

4 to 20 mA or 0 to 10 VDC $

Communications

No Serial Output

Isolated RS-232

Isolated RS-485 Half Duplex $

Input Signal

0–750 VAC User Programmable

0–5 AAC User Programmable

$

N/C

N/C

N/C

N/C

70

N/C

80

N/C

$110

110

N/C

N/C

IDP ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: IDP-0

A – B

A

B

4

5

Basic Unit

IDP

IDT

IDpH

4-Digit Process Meter

4-Digit Thermocouple Meter

4-Digit pH Meter

1

2

Display/Power

0 Red/115 VAC

3

Red/230 VAC

Green/115 VAC

Green/230 VAC

Red/10–32 VDC

Green/10–32 VDC

$195

$225

$245

N/C

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Newport

Digital Panel Meters/Controllers

i8

These meters accept universal inputs—thermocouple, RTD, process voltage/current. Panel mounted, with NEMA-4 (IP65) front bezel, they offer multiple “firsts” for 1/8 DIN instruments:

• Display Changes Colors at Set Point

(Yellow, to Green, to Red)

• Fully Programmable Color Display and the Largest

Display (21 mm LEDs) of Any 1/8 DIN Instrument

• RS-232 and RS-485 Serial Communications (Optional) in One Instrument

• Built-In Excitation (10 or 24 VDC) is standard

Units also feature ±0.5°C accuracy, free Active X Controls software, extended

5-year warranty at no extra charge. Available as monitors only or with two control/alarm outputs.

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: i8-2-0-DC

A – B – C – D

A Base Units i800 Monitor only (no control outputs) 1/8 DIN $ 240 i8C00 Monitor only (no control outputs) 1/8 DIN Short Case *2 $ i8A00 Monitor with Isolated Analog Output 1/8 DIN $ 295 i8 Two control outputs 1/8 DIN $ 310 i8C i8A

Two control outputs 1/8 DIN Short Case *2 $ 355

Isolated Analog Output with two control outputs *1 365

B Control Output #1 & #2 Direct (Cool) or Reverse (Heat) Acting

22 Two solid state relays (SSR’s) N/C

23

24

SSR and relay: Form “C” SPDT

SSR and pulsed 10 Vdc(for use with external SSR)

N/C

33

34

44

2 Relays: Form “C” SPDT

Relay and pulsed (for use with external SSR)

Two pulsed 10 Vdc (for use with external SSR)

N/C

N/C

N/C

52

53

E1

C24

Analog Output (control or retransmission)

Analog Output and Relay

54 Analog Outputand Pulse

C Network Options

N/C

N/C

N/C

Ethernet with Embedded Web Server $ 55

Isolated RS-232 and RS-485 (MODBUS & ASCII) $0

C4EI Ethernet with Embedded Internet + Isolated RS-485 $

D Power Supply

AC

DC

Standard Power : 90 to 240 VAC/DC

10-34 Vac/dc (optional)

N/C

$ 25

*1 Not Available for the i8A Controller

*2 Not Available in the Compact Case

• 6-Digits

• NEMA-4 (IP65) Front Bezel

• Four Isolated Open Collector Outputs

• Peak and Valley Detection and Memory

• Digital Tare

• 1.5 to 11 or 24 VDC Sensor Excitation

INFU

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: INFP-0-2-1-0-C2

A – B – C – D – E – F – G

A

B

C

D

E

F

G

Basic Unit

INFP

INFS

DINFW

INFT

INFU

Process (DC Voltage and Current)

Strain Gauge

Weight

Thermocouple and RTD

$ 545

$ 545

$ 595

$ 595

Universal Input (Process, Strain and Temp.) $ 645

Split Display–Insert Only If Required

Z Split Display (insert “Z” after INF in basic unit) $

1

2

3

Power and Display

0 115 VAC, Red LED

230 VAC, Red LED

115 VAC, Green LED

230 VAC, Green LED

N/C

N/C

N/C

N/C

$ 110

$ 110

4

5

10–32 VDC, Red LED

10–32 VDC, Green LED

Control Output

0 Four NPN Open Collectors

0

1

1

2

Isolated Parallel BCD

Two 7A Relays

3 Two 7A Relays and Two 1A Relay

Analog Output

None

Isolated Analog Output

N/C

$ 110

$ 75

$ 175

N/C

$ 110

1

2

Serial Output

0 None

Isolated RS-232

Isolated RS-485

Input Signal

Specify T/C, RTD, or DCV

N/C

$ 110

$ 110

N/C

22

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Simpson

Digital Meters/Controllers

23

Includes new temperature measurement models (H340)

• All Parameters Set from Front Panel

• 7 Segment 41

/

2 or 31

/

2

Digit Bright Red Display

• Screw Terminals for Easy Installation

• 1/8 DIN Shallow Depth Case

• Peak/Valley and Password Lockout

• Optional Plug-In Output and Excitation Cards

• Optional Plug-In Cards for One, Two or Four 5 Amp Relays

• NEMA 4X Rated Front Panel

SPECIFICATIONS

Display

Type:

Quantity:

J

Height:

Decimal Point:

AC:

Sensor Type

RTD Pt 100

K

E

T

Mechanical

7 segment, red LED

H335: 3 1

/

2 digit; H345: 4 1

/

2 digit; H340: 4 digit

0.56" (14.2 mm)

H335 and H340: 4-position, user programmable H345: 5- position, user programmable

5 Levels, user programmable Brightness:

Alarm Indicators: 4 LED indicators for up to four set points

Power Requirements

AC Voltages:

DC Voltages:

Accuracy @ 25°C:

120, 85-250 VAC @ 10VA

9–36 VDC @ 10 VA

DC: H335: 0.1% of input ±1 digit

H345: 0.05% of input ±1 digit

H335: 0.2% ±2 digits

H345: 0.1% ±2 digits

Accuracy Temperature Range

0.2% of input ±2 count -200°C to +200°C

0.2% of input ±2 counts -100°C to +760°C

0.2% of input ±2 counts -200°C to +1250°C

0.2% of input ±2 counts -100°C to +800°C

0.2% of input ±2 counts -200°C to +400°C

Bezel:

Depth:

Panel Cut-out:

Case Material:

Weight:

Temperature:

Sample Rate:

1

3.93 x 2.04 x .52" (98.8 x 51.8 x 13.2 mm)

3.24" (82.33mm) behind panel

/

8

DIN 3.62 x 1.77" (92 x 45 mm)

PBT-ABS

10 oz (283.5g)

0-50°C

10/sec

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

A – B – C – D – E – F

NEW

A Basic Temperature Meter

H340 4 digit Red LED

B Power Supply

1

2

4

120V AC

9-36V DC

85-250V AC

C Function Range

91

92

93

94

95

J Thermocouple

K Thermocouple

RTD, Pt100, 3-wire

E Thermocouple

T Thermocouple

D Analog Output

0 None

1

2

4-20 mA DC

0-10V DC

E 5 Amp Relays

2

4

0

1

None

One

Two

Four

F Excitation Output

0

1

2

None

12V DC (30mA max)

24V DC (30mA max)

H335

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: H335-2-46-0-1-2

A – B – C – D – E – F

A

B

C

Basic Panel Meter

H335 3

1 /

2

digit Red LED

H345 4

1 /

2

digit Red LED

Power Supply

1 120VAC (3

1 /

2

digit only)

2 85-250 VAC (4

1

/

2

digit only)

12

13

14

15

3

4

3 9–36 VDC

85-250 VAC (3

1 /

2

digit only)

Function/Range

11 200mV DC 51 200mV AC TRMS

2V DC

20 VDC

200V DC

600V DC

52 2V AC TRMS

53 20V AC TRMS

54 200V AC TRMS

55 600 AC TRMS

D

E

F

21

22

23

24

25

26

200µA DC

2m ADC

20mA DC

200mA DC

2A DC

5A DC

61 200µA AC TRMS

62 2mA AC TRMS

63 20mA AC TRMS

64 200mA AC TRMS

65 2A AC TRMS

66 5A AC TRMS

31

32

33

34

35

200mV AC

2V AC

20V AC

200V AC

600V AC

41

42

43

44

45

200µA AC

2mA AC

20mA AC

200mA AC

2A AC

0

1

46 5A AC

Output Signal

2

None

4–20 mA DC Process

0–10 VDC Process

6 RS-485 (4

1

/

2 digit only)

5 Amp Relay Outputs

0 None

71 4-20mA DC Process

72 0-10V DC Process

81 200 Ohm

82 2k Ohm

83 20k Ohm

84 200k Ohm

1

2

4

One

Two

Four

1

2

Excitation Output (not available with Signal Output)

0 None

12V DC (30mA max)

24 DC (30mA max)

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Simpson

Digital Panel Meters

F35

M235

• Case Size: Standard 1/8 DIN

• Accuracy: ±0.2% (F35); ±0.05% (F45DC); ±0.5% (F45AC)

• Auto-Zero

• Choice of AC or DC Power Supplies

• Broad Range Scaling and Adjustable Zero Offset for Process Inputs

• User-Selectable Decimal Points

• Optional Excitation Output 12 VDC or 24 VDC

• Easy Installation Using Screw Terminals

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number

Order Example: F35-1-12-1

A – B – C – D

A

B

C

D

Basic Unit

F35

F45

3

4

1

1

Power Supply

/

2

-Digit Meter

/

2

-Digit Meter

3

4

1

2

120 VAC

220 VAC

9–32 VDC

120 VAC CE

Input Range

DC Voltage

200 mV 11

2V

20V

200V

750V

12

13

14

15

DC Current

AC Voltage

31

32

33

34

35

AC Current

0

1

2

200 µA 21

2 mA 22

20 mA 23

200 mA 24

2A

5A

25

26

Process

71 4–20 mADC

72 1–5 VDC

73 1–10 VDC

41

42

43

44

45

46

Temperature (F45 only)

80 J T/C

81 K T/C

82 S T/C

84

85

86

83 T T/C

Frequency

20–199.9 Hz

20–1999 Hz

91

92

90

RMS (F35)

Excitation Output (DC Input Only)

None

12 VDC

24 VDC

61

62

63

64

65

66

AC RMS

51

52

53

54

55

AC RMS

E T/C

R T/C mV DC

RTD PT 100

Sq. Wave (F35)

93

94

• Case Size: Standard 3/64 DIN Dimensions

• Accuracy: ±0.5% (M235); ±0.5% (M245)

• Minimum Depth Indicator—Less Than 2.5" (60 mm) of Space

• User-Selectable Decimal Point

• Optional Negative Image, Bright Red Backlighting

• Standard Screw Terminals

• 85V to 250 VAC Power or 9V to 32 VDC

Mini-Max—3/64 DIN, 3 1 ⁄

2 and 4 1 ⁄

2

Digit

AC and Process Indicators

Simpson’s Mini-Max AC Voltage/Current Indicators provide high quality, accuracy, and reliability in a compact 60 mm deep case.

Power:

Size:

SPECIFICATIONS

85V–250 VAC @ 40 Hz–440 Hz; or 9V–32 VDC

2.84W x 0.95 x 2.36" WHD (72 x 24 x 60 mm)

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: M235-1-0-11-0

A – B – C – D – E

A

B

C

D

E

Basic Unit

M235 3

1

/

2

-Digit LCD Meter

M245 4 1 /

2

-Digit LCD Meter

Display

0

1

Non-Backlit

Negative Red Backlight

Supply Voltage

0

2

85–250 VAC

9–32 VDC*

Function Range

11 200 mVDC

12 2 VDC

13 20 VDC

14 200 VDC

15 750 VDC

21 200 µADC

22 2 mADC

23 20 mADC

24 200 mADC

25 2 ADC

26 5 ADC

71 4–20 mADC

72 1–5 VDC

73 0–10 VDC

74 0–100 VDC

31 200 mVAC TRMS

32 2 VAC TRMS

33 20 VAC TRMS

34 200 VAC TRMS

35 750 VAC TRMS

41 200 µAAC TRMS

42 2 mAAC TRMS

43 20 mAAC TRMS

44 200 mAAC TRMS

45 2 AAC TRMS

46 5 AAC TRMS

81 20–199.9 Hz

82 20–1999 Hz

83 20–199.9 Hz Sq. Wave

84 20–1999 Hz Sq. Wave

Excitation Output (NA with Frequency)

0

1

2

None

12 VDC

24 VDC

* Not Available on Frequency (Hz) Meters

24

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Laurel

High Performance DPM

FEATURES

• ±99999 Display Span

• User Selectable Ranges

• 60 Readings Per Second

• Adaptive Averaging Filter

• 1/8 DIN, NEMA-4X Front

• 5, 10, 24V DC Excitation Out

OPTIONS (all outputs isolated)

• Dual Setpoint Controls Output

• Linearized 0-10V & 0-20 ma

Analog Transmitter Outputs

• RS-232 & RS-485 Data I/O

• Custom Curve Linearization

• Datalogging PC Software

Laureate™ DPMs offer exceptional flexibility in measuring DCV, ACV, DCA, ACA, temperature, weight, strain, process & pot follower.

Display

A-to-D Conversion

A-to-D rate

Display update

Accuracy at 25°C

DC error

Load Cell ..

True RMS

SPECIFICATIONS

Five 14.2 mm (.56”) high LED digits

60/s at 60 Hz, 50/s at 50 Hz

3.5/s at 60 Hz, 3/s at 50 Hz

< 0.01% FS ±1 ct

< 0.01% FS ±1 ct

< 0.1% FS (1-100%, 10 Hz-10 kHz)

CF = 2.4 at full scale

25

Noise Rejection

CMR, DC to 60 Hz 130 dB

NMR to 50/60Hz line 90 dB with min filtering

Transducer Excitation Output (std)

5V, 100 mA; 10V, 120 mA; 24V, 50 mA Output

Dual Relay Output (opt)

Contact relays .

10A @ 250 Vac, 8 A @ 24 Vdc

Solid state relays 0.12A @ 125 Vac, 0.25A @ 150 Vdc

Linerarized Analog Output (opt)

Level 0-20 mA or 4-20 mA plus 0-10 Vdc

Resolution

Environmental

12 bits (0.025%)

Operating temperature 0°C to 55°C

Humidity 95% RH at 40˚C, non-condensing

Data Communications (opt)

RS-485

BCD

Half or full duplex

6 decades parallel

ORDERING INFORMATION

Example: L10010DCV1

Laureate Series

L Laureate Panel Meter

LW Laureate Weight Meter

Main Board

1 DPM with green LEDs

2

3

DPM with red LEDs

Extended, green LEDs

4 Extended, red LEDs

Note: Extended capability for DPMs is required for custom curve linearization.

Power

0 85-264 Vac/90-370 Vdc

1 9-37 Vdc/8-28 Vac

Setpoint Output

0 None

1 Dual 10 A relays

Analog Output

2

0

Dual solid state relays

None

Digital Interface

1

0

0-20 mA & 0-10 V

None

1

2

3

RS-232

RS-485

BCD output

Input Type

DC Volts

DCV1 200.00 mV

DCV2 2.0000 V

DCV3 20.000 V

DCV4 200.00 V

DCV5 660.0 V

DC Amperes

DCA1 2.0000 mA

DCA2 20.000 mA

DCA3 200.00 mA

DCA4 5.000 A

Process Signals

(4-20 mA, 0-5 V, etc.)

P

P1

4-20 mA = 0-10000

Custom Scaling

Strain Gage, Potentiometer

(4-wire ratio)

SG

SG1

0-200 mV = 0-20000

Custom Scaling

Note: The same DC signal conditioner board can be user configured for DC Volts, DC Amps, process, or strain.

100-Ohm Platinum RTDs P385C -202 to 850°C

P385F -331 to 1562°F

P392C -202 to 850°C

P392F -331 to 1562°F

Thermocouples

JC -210 to 760°C

JF -347 to 1400°F

KC -244 to 1372°C

KF -408 to 2501°F

TC -257 to 400°C

TF -430 to 752°F

EC -240 to 1000°C

EF -400 to 1830°F

NC -245 to 1300°C

NF -410 to 2370°F

SC -46 to 1768°C

SF -51 to 3214°F

RC -45 to 1768°C

RF -49 to 3213°F

Note: The same temperature signal conditioner board can be user configured for all T/C and RTD types

RMS Volts

RMS Amperes

RMV1 200.00 mV

RMV2 2.0000 V

RMV3 20.000 V

RMV4 200.00 V

RMV5 660.0 V

RMA1 2.0000 mA

RMA2 20.000 mA

RMA3 200.00 mA

RMA4 5.000 A

Note: The same AC RMS signal conditioner can be user-configured for AC Volts or Amps

Load Cells (6-wire ratio) WM1 -99,999 to +99,999

Note: Excitation is 10V DC for up to four 350Ω load cells in parallel

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Selco

Digital Panel Meters

Universal Type Digital Panel Meter

• UL, CSA & CE Approved

• Seven Output Choices

• Front Panel Membrane Set Buttons

• Eighteen Input Choices

• Available Two Setpoint Displays

• 90-264VAC or 9-60VDC Power Supply

• RS-232C/RS-485 Communications

• Industry Standard 1/8 DIN Size

• 8-Amp Setpoint Contact Relays

A5000 Series

Main display:

Sub display:

Conversion rate:

Maximum display:

SPECIFICATIONS

4 Digit Red LED 14.2mm

Dual, Green LED 8mm (Hi & Lo setpoints)

12.5 times/sec

9999

Overrange indication: When input exceeds the maximum display, display OL or -OL

Zero display:

Decimal point:

External control:

Leading zero suppression

Settable to any digit position

Start/Hold, Peak Hold, Digital Zero

Operating temperature: 0 to 50°C, 35 to 85% RH

Storage temperature: -10 to 70°C less than 60% RH

Power supply: AC 100 to 240V ±10% (AC main unit)

DC 9 to 60V (DC main unit)

Power consumption: Approx. 4VA (at 100V)

Dimensions: 96mm x 48mm (H) x 147.5mm (D) DIN size

Dielectric strength (AC): Power supply/input terminal/output terminal 2000VAC/1 min.

Input terminal/output terminal 500VDC/1 min.

Case/power supply/input terminal/output terminal 2000VAC/1 min.

Dielectric strength (DC): Power supply/input terminal/output terminal 500VDC/1 min.

Input terminal/output terminal 500VDC/1 min.

Case/power supply/input terminal/output terminal 2000VAC/1 min.

Insulation resistance: 500VDC more than 100MΩ at the above terminals

Input:

AC Voltage:

AC Current:

Frequency:

40Hz to 1kHz

40Hz to 1kHz

0.1Hz to 200kHz

30V p-p Max.

Strain Gauge:

Adjustment Span:

Excitation:

Analog Output:

Setpoint Relays:

1 to 3 mV/V

5V@15mA, 10V@30mA

0-1V, 0-10V, 1-5V, 4-20mA

8A@240VAC, 30VDC Resistive

ORDERING INFORMATION

Example SE/A51/25-03

SE/A5

A B C

-

D

1

2

AC 100 - 240V (±10%)

DC 9 - 60V

1 Single (Main Display Only)

2 Multiple (Main & Sub Displays)

C Output

0

1

2

None

HI & LO setpoint

Analog output

D

5

6

3

4

7

RS-232C

RS-485

HI & LO setpoint + analog output

HI & LO setpoint + analog output + RS-232C

HI & LO setpoint + analog output + RS-485

Input

01 DC voltage (±99.99mV)

02 DC voltage (±999.9mV to ±600V)

03 DC current (±9.999mA to ±999.9mA)

04 AC voltage AVG (99.99mV to 9.999V)

05 AC voltage AVG (99.99V to 600V)

06 AC voltage RMS (99.99mV to 9.999V)

07 AC voltage RMS (99.99V to 600V)

08 AC current AVG (9.999mA to 999.9mA)

09 AC current AVG (5A)

10 AC current RMS (9.999mA to 999.9mA)

11 AC current RMS (5A)

12 Resistance (99.99Ω to 99.99KΩ)

13 Temperature (Thermocouple)

14 Temperature (RTD)

15 Frequency (Open collector, Logic, Magnet)

16 Frequency (50 to 500Vrms)

17 Strain gauge

18 1 to 5V, 4 to 20mA

2

3

2

3

1

4

3

Ranges

1

3

3

1

4

JKTSRB

Pt100

4

26

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Selco

Digital Panel Meters

4

1

/

2

Digit DC Voltmeter & Ammeter AP-141

• Low Cost 1/8 DIN Size

• Bright 0.56" LED (Red)

• 2V, 20V, 200V

Measurement Ranges

• 180~264V and

90~132V Power

4

1

/

2

Digit DC Voltmeter A2200

• 10mm (0.39") Red LEDs

• 1/32 DIN Case

• Isolated Power

NEW

SPECIFICATIONS

Input configuration:

Accuracy:

Single ended

±0.03% Rdg ±1 Digit

Input bias current:

Conversion rate:

(@ 18-28°C)

100pA (Typ.)

2.5/sec.

Normal mode rejection: More than 50dB (50/60Hz)

Zero stability:

Display:

Automatic zero adjustment

LED, 14.2mm 4 1

/

2

-digit

Polarity:

Decimal point:

Overrange indication:

A “-” is displayed automatically

Settable to any digit position

When input exceeds the maximum display,

0000 or - 0000 flashes

Power supply: 90~132VAC

180~264VAC

5VDC±5% 150mA (Max.)

24VDC±20% 35mA (Max.)

Operating temperature: 0~50°C, 35 to 85%RH

Power consumption:

Dimensions:

Weight:

Dielectric strength:

(with AC Power)

2VA

48mm(H)x96mm(W)x73mm(D) 1

/

8

DIN size

Approx. 160g (For AC), 90g (For DC)

Between input (Lo) terminal and earth, 500VDC Between power supply terminal and input terminal, earth, common,

Dielectric Strength

(with DC Power)

Insulation resistance: case, 1500VAC/1 min.

DC type; between input (Lo) and power supply (0V), 500VDC

Between input (Lo) and power supply (0V), 500VDC

DC500V 100MΩ at above terminals

DC Voltage Measurement

Model Range

AP-141-12 ±1.9999V

AP-141-13 ±19.999V

AP-141-14 ±199.99V

Maximum Input Input

Resolution Impedance Protection

100µV 100MΩ ±100V

1mV

10mV

1MΩ

1MΩ

±250V

±500V

SPECIFICATIONS

Accuracy:

Input configuration:

Conversion rate:

Overrange indication:

Decimal point :

± 0.1% of F.S.

Single Ended

2.5/sec

0000 or -0000 flashes

Front switch settable

External control:

Power:

Hold

5-24VDC, 100mA

Operating temperature: 0-50°C, 35-85% RH

Dimensions: 48mm(W) x 24mm(H) x 39.7mm(D)

Dielectric strength: 500VDC input to power

Model

A2200-12

A2200-13

A2200-14

Maximum

Reading

±1.999V

±19.99V

±199.9V

Input Input

Impedance

100MΩ

1MΩ

1MΩ

Replacement for AP-241A, AP-242A, AP-244A(no option)

Protection

±50V

±250V

±250V

A2200-12

A2200-13

A2200-14

ORDERING INFORMATION

2VDC Voltmeter, 4 1

/

2

Digit

20VDC Voltmeter, 4 1

/

2

Digit

200VDC Voltmeter, 4 1

/

2

Digit

3

1

/

2

Digit DC Meter A2100

• 10mm (0.39") Red LEDs

• 1/32 DIN Case

• Voltage or Current Input

SPECIFICATIONS

Voltage accuracy:

Current accuracy:

±0.1% of F.S

±0.2% of F.S.

Input configuration: Single Ended

Conversion rate: 2.5/sec

Overrange indication: 0000 or -0000 flashes

Decimal point : Front switch settable

External control: Hold

RH

35temperature: 85%

Dimensions: 48mm(W)

24mm(H) x 39.7mm(D)

Dielectric strength: 500VDC input to power

Range

-11

-12

-13

-14

-22

-23

-24

-25

Maximum

Reading

±199.9mV

±1.999V

±19.99V

±199.9V

±1.999mA

±19.99mA

±199.9mA

±1.999mA

Input Input

Impedance

100MΩ

100MΩ

1MΩ

1MΩ

100Ω

10Ω

1Ω

0.1Ω

Replacement for AP-200, AP-201A, AP-202A(no option)

Protection

±50V

±50V

±250V

±250V

±50mA

±150mA

±500mA

±3A

27

ORDERING INFORMATION

Example AP-141-12-1

AP - 141 A B

AP-141 4 1

/

2

Digit Voltmeter

A Range

12 ±2VDC Input

B

13 ±20VDC Input

14 ±200VDC Input

Power Supply

1

2

3

AC90~132V

AC180~264V

DC5V (Isolated)

4 DC24V (Isolated)

A21 A

-

B

ORDERING INFORMATION

A Power Supply

10 5VDC@60mA non-isolated

B Range

11 ±199.9mV

12 ±1.999V

13 ±19.99V

14 ±199.9V

22 ±1.999mA

23 ±19.99mA

24 ±199.9mA

25 ±1.999A

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Weschler

AC/DC Meters/Controllers

• ±1,999 and ±19,999 Count Displays

• Low-Cost Alarm Meter Option

• Dual Changeover Alarm Option

• Analog Retransmission Option

• 1/8 DIN Panel Format

• Clear, Bright Display

• Simple to Install

• Detachable, Coded Screw Terminals

• High-Noise EMI Immunity

• Isolated BCD Option

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: ACI-3-W-A-10-0

A – B – C – D – E

A

B

C

D

E

Basic Unit

ACI-3

ACI-4

ACI-4L

ACV-3

ACV-4

ACV-4L

DCI-3

3

4

1

1

/

2

-Digit Meter/Controller

/

2

-Digit Meter/Controller

4-Digit, Large Display (0.8" digits)

3 1 /

2

-Digit Meter/Controller

4 1 /

2

-Digit Meter/Controller

DCI-4

DCI-4L

DCV-3

DCV-4

DCV-4L

PRO-3

4

4-Digit, Large Display (0.8" Digits )

3

4

4-Digit, Large Display (0.8" digits)

3 1 /

2

-Digit Meter/Controller

1

1

1

/

2

-Digit Meter/Controller

/

2

-Digit Meter/Controller

/

2

-Digit Meter/Controller

4-Digit, Large Display (0.8" Digits )

3

1

/

2

-Digit Meter/Controller

PRO-4

PRO-4L

4 1 /

2

-Digit Meter/Controller

4-Digit, Large Display (0.8" Digits)

Load-3

Load-4

3

4

1 /

2

-Digit Meter/Controller

1 /

2

-Digit Meter/Controller

Load-4L 4-Digit, Large Display (0.8" Digits )

Output

X

Y

N

W

RS232

Supply Voltage

None

Analog Output

Dual Relays with Analog Output

Dual Relays, 7 Amps 250 VAC

RS-232 Serial Output

A 110 Volts

B 220 Volts

Input Range

DCI-3/ACI-3

7 19.99 mA

8 199.9 mA

9 1999 mA

10 5.00 AAC

DCV-3/ACV-3

1 199.9 mV

2 1.999V

3 19.99V

4 199.9V

5 600V

PRO-3 and PRO-4/4L

21 4–20 mADC

22 0–1 mADC

23 0–10 VDC

24 1–5 VDC

Load-3 and Load-4/4L

1 20 mV

2 100 mV

Options

0 None

1 Green Display

2 RMS Input Convertor

F 24 Volts AC

G 48 Volts AC

H 10-30 Volts DC

DCI-4/ACI-4

15 19.999 mA

16 199.99 mA

17 1999.9 mA

18 5.000 AAC

DCV-4/ACV-4

10 199.99 mV

11 1.9999V

12 19.999V

13 199.99V

14 600.0V

ACI-3

SPECIFICATIONS

Input Ranges

Model ACI-3, ACI-3X, ACI-3W, ACI-3Y: 0–19.99 mA, 0–199.9 mA,

0–1999 mA, 5.00A

Model ACI-4, ACI-4X, ACI-4W, ACI-4Y: 0–19.999 mA, 0–199.99 mA,

0–1999.9 mA, 5.000A

Model ACV-3, ACV-3X, ACV-3W: 0–1.999V, 0–19.99V,

Model ACV-4, ACV-4X, ACV-4W:

Model DCI-3, DCI-3X, DCI-3W:

Model DCI-4, DCI-4X, DCI-4W:

Model DCV-3, DCV-3X, DCV-3W:

Model DCV-4, DCV-4X, DCV-4W:

Model Pro-3, Pro-4:

Model Load-3, Load-4:

Accuracy

Of Range:

Display

Format:

0–199.9V, 500V

0–1.9999V, 0–19.999V,

0–199.99V, 500V

0–19.99 mA, 0–199.9 mA,

0–1.999A, 0–5.00A

0–19.999 mA, 0–199.99 mA,

0–1.9999A, 5.000A

0–199.9 mV, 0–1.999 mV,

0–19.99V, 0–199.9V

0–199.99 mV, 0–1.9999V,

0–19.999V, 0–199.99V, 500.0V

4 mA–20 mA, 0–1 mA, 0–10V, 1–5V

0–20 mV, 0–100 mV

1%, ±2 digits @ 75°F/25°C

7-segment, 0.56" (14.2 mm), red LED

Selectable by push-on jumper Decimal Point:

Alarm Output Option

Format: HI-LO (default), HI-HI, LO-LO, all failsafe

Analog Output Option

Outputs Available: 0–10V or 4 mA–20 mA, jumper-selectable, ±0.025% of range

0–500Ω

500Ω to infinity

4mA–20mA Load Limits:

0–10V Load Limits:

Power

Jumper Selectable:

Optional:

Size

Display Bezel:

Panel Cutout:

Environmental Limits

Operating Temperature:

Humidity:

115 VAC or 220 VAC, ±10% 3 VA

5 VDC, 12 VDC or 24 VDC

1/8 DIN (96 x 48 mm)

3.62” L x 1.77" W (92 x 45 mm)

32°F–125°F (0–50°C)

0–85% RH non-condensing

28

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

29

Weschler

Programmable Meter/Controller

Intuitive

• Simplified Programming

• 8 Program Memories

• Display Filtering

• Last Digit Round-Up

• Optional NEMA (IP67) Front Cover (Call for Details)

• 10-Point Custom Linearization

This new and unique adjustment system offers unparalleled benefits. Now no more menus to scroll through—just go directly to the parameter you wish to adjust. Programming features include: Scaling,

Analog Output, Alarm Output, and 10-point Linearization.

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: Intuitive-AI-0-0-232-R-0

A – B – C – D – E – F – G

A

B

Basic Unit

Intuitive Meter/Controller

Input

C

F

U

AI

AV

DI

DV

AC Current

AC Voltage

DC Current

DC Voltage

Counter/Totalizer

Frequency/Rate

Process/Temp.

C Analog Output

0

ANI

None

4–20 mA

D Alarm Output

0

AL2

None

2 Alarms

E Serial Data Output

0

232

None

RS232

P

R

I

L

S

T

Integrator (Totalizer)

Loadcell

Process

Resistance

Serial Data

Temperature

ANV 0–10V

ANB -5 to +5V

SP 4 Alarms

422 RS422

485 RS485, addressable

DN Device Net

F Display Color

R

G

Red

Green

G Supply Voltage

0 95–265 VAC

DCPSU 11–30 VDC

National Meter

KW Hour Meters

Three Phase Energy & Demand Meters

• Six Digit kWh LCD Display

• L1, L2 & L3 Power Readings

• Three Digit V, A & kW Readout

• kWh Pulse Relay

• RS-485 Modbus RTU Output

• Use with CTs Rated to 10,000A

Displays kWhrs and kW Demand along with

Volts, Amps and real time kW per phase.

SPECIFICATIONS

KW4000

Burden: Isolated CT circuit, burden 0.06VA

Operating Temperature: -10°F to 120°F, <95% RH non-condensing

Relay Output: SPST Form A, 240VAC@10A resistive

Dimensions:

Enclosure:

Connections:

Dimensions:

7.5"W x 8" H x 3.5" D

Surface mount, ABS plastic, NEMA 1

Screw terminals

5.6" W x 8.1" H x 3.5" D

• 3Ø Revenue Class Meter

• 9 Digit LED Display

• Field Programmable

• Memory Backup Without

Batteries

• Direct Energy Display

– No Multipliers

K4000PM

NEW

SPECIFICATIONS

Max Display:

Accuracy:

999,999,999 kWh

±0.5% ±2d

Burden: Isolated CT circuit, burden 0.75VA

Operating Temperature: -10°C to 50°C

Relay Output:

Contacts:

Indicator:

Enclosure:

Dimensions:

Standards:

Energy/alarm pulse, 1/sec max rate

440VAC, 10A, 2500VA resistive

Front panel LED

UL VO rated plastic, NEMA 1

3.78"W x 3.78" H x 3.3" D

CAT III 300V, Class II double insulated

ORDERING INFORMATION

CAT NO.

NM/KW4240

DESCRIPTION

120/208/240V 3Ø, 3 or 4 Wire, KWh/Demand Meter

NM/KW4480 277/480V 3Ø, 3 or 4 Wire, KWh/Demand Meter

NM/K4240PM 120/208/240V 3Ø, 3 or 4 Wire, KWh Meter

NM/K4480PM 277/480V 3Ø, 3 or 4 Wire, KWh Meter

400A solid core CTs included. Split core and larger sizes available. Single phase models also available.

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Yokogawa

AC Watt/VAR, Phase Angle and PF Meters

Click Here to

Order Online

• Suitable for Power Measurement of Distorted Waveforms

Such as a Thyristor Waveform

• Maintains Standard (IEC or ANSI 39.1) for Switchboard

Dielectric Strength and Circuit Usage Conditions

• Isolated Input and Output Circuits Via Isolation Transformer

• Automatic Frequency Compensation Circuit

• Can be Used in Unbalanced Circuits

• Size: 3.78 x 1.89 x 6.3" WHD

2355

35

2355/2356 SPECIFICATIONS

Accuracy: 0.1% @ ±10% input voltage variation

±0.25% of reading ±1 digit ±0.25% of FS for 45 Hz–65

Hz

Frequency Range: 40 Hz–500 Hz (2355 Watts); 45 Hz–65 Hz (2356 VARS)

Weight: Approx. 1.3 lb

Resolution:

Accuracy:

Frequency Range:

Weight:

2357 SPECIFICATIONS

Phase Angle

0.1°

0.1°

45 Hz–65 Hz

1.3 lb

Power Factor

0.001PF

±1.0°

45 Hz–65 Hz

1.3 lb

Voltage:

Current:

2355/2356 STANDARD RANGES

120V or 240 VRMS

(Up to 600 VAC available upon request)

1A or 5 ARMS (Up to 10A available upon request)

2355/2356 ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: 2355-10-40-04-1-0-FS (0-150.0)

A – B – C – D – E – F – G

A

B

C

D

E

F

G

2

3

0

1

4

5

Scaling

S

FS

Basic Unit

2355

2356

Watt Meter

VAR Meter

Function/Connections

10

20

30

40

Voltage Input

Single-Phase, 2-Wire

Single-Phase, 3-Wire

Three-Phase, 3-Wire

Three-Phase, 4-Wire**

40

70

120 Volt AC

240 Volt AC

Current Input

02 0–1 Amp AC

04 0–5 Amp AC

2

3

Display Multiplier

1 No Fixed Zero

1 Fixed Zero

2 Fixed Zero

Analog Output

No Output

1 mV/Digit

5 mV/Digit

1 to 5 VDC

0 to 1 mA DC

4 to 20 mA DC

Standard (input range and scale are the same)

Factory Scaling (custom—specify scaling)

**Specify auxiliary power of either 100, 117, 220, or 240 VAC for 3P4W only if analog output is selected.

Voltage:

Current:

2357 STANDARD RANGES

Phase Angle

60V–300V

1A–5A

Power Factor

60V–300V

1A–5A

2357 ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: 2357-10-40-04-10-FS (0-1800)

A – B – C – D – E – F

A

B

C

D

E

F

Basic Unit

2357 3 1 /

2

-Digit Meter

Function/Connections

10 Phase Angle 1P2W

11

20

21

30

31

40

41

Power Factor 1P2W

Phase Angle 1P3W

Power Factor 1P3W

Phase Angle 3P3W

Power Factor 3P3W

Phase Angle 3P4W

Power Factor 3P4W

Voltage Input

40

70

120 Volt AC

240 Volt AC

80 60 to 300 VAC (phase angle model only)

Current Input

02

04

0–1 Amp AC

0–5 Amp AC

Analog Output

10 No Output (power factor model only)

11

12

13

14

15

Scaling

1 mV/Digit

5 mV/Digit

1 to 5 VDC

0 to 1 mA DC

4 to 20 mA DC

S

FS

Standard (input range and scale are the same)

Factory Scaling (custom specify scaling)

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

NLS

Panel Meters

MINIATURE PANEL METERS

PM349

• 0.1% Basic DC Accuracy

• Small Stackable Case

• Red, Green or Yellow Display

• Presettable Decimal Point

• MUX BCD Outputs

Case Size: 3.125"W x 1.375"H x 3.375"D

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: NL/PM349/L/G/CS/5/20V

D Reading

A – B – C – D – E – F

– Normal

A Model

S

Z

Scaled (specify value)

Offset (specify value)

NL/PM349 3 1

/

2 digit DC Voltmeter

NL/PM352 3 1

/

2 digit DC Voltmeter

CS

AC

Internal current shunt (specify range)

AC reading (PM352 only)

NL/PM452 4 1

/

2 digit DC Voltmeter

E Power

B Dislay Option

L

C LED Display Color

R

Y

G

0.3" LED digit height

Large 0.4" digits

Red

Yellow

Green

F

5

120

240

Range

200mV

2V

20V

20V

1000V

Normal

5VDC ±5%, 200mA with 120VAC adapter with 240VAC adapter

Rin

100MΩ (PM349 only)

1000MΩ

1MΩ

10MΩ

10MΩ

SHORT DEPTH DC VOLTMETERS

X37

• Only

1

/

2

" behind panel

• 0.56" LED or 0.6" LCD

• 0.1% or 0.2% Accuracy

• Presettable Decimal Point

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: NL/X37/L/-/20V

A

B

C

A – B – C – D – E

Model

NL/X32 3 digit, LED (unipolar)

NL/X34 3 1

/

2 digit, LED (bipolar)

NL/X37 3 digit, LCD (bipolar)

Dislay Option

R

Y

G

L

Backlit LCD

Standard LCD or LED

LED Display Color

Red LED

Yellow LED

Green LED

LCD

D Reading

S

Z

CS

E Range

Normal

Scaled (specify value)

Offset (specify value)

Internal current shunt

(specify range)

X32 X34, X37

100mV 200mV

1V 2V

10V

100V

20V

200V

1000V 1000V

Rin

100MΩ

1MΩ

1MΩ

1MΩ

4MΩ

Power: 5VDC ±5%, 200mA

(6mA for X37)

Case Size: 4"W x 1.9"H x 1.1"D

1/8 DIN PANEL METERS

RM350

• 0.1% or 0.2% Accuracy

• Amps, AC, Ω, Ratio Options

• Power Supply Options

• MUX BCD Outputs

Case Size: 4.0"W x 1.9"H x 4.5"D

A

B

C

D

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: NL/RM350/TB/-/G/AC/120/20V

A – B – C – D – E – F – G

Model

NL/RM350 3

1

/

2 digit, 0.56" LED

NL/RM351 3

1

/

2 digit, 0.6" LCD

NL/RM452 4

1

/

2 digit, 0.56" LED

NL/RM453 4

1

/

2 digit, 0.4" LCD

Connector (mating connector included)

TB

EC

Dislay Option

Terminal block

Edge connector

L

Standard

0.8" LED

(RM350 only)

Display Color

R

Y

G

Red LED

Yellow LED

Greeen LED

LCD

E

F

5

12

24

28

18

120

240

G Range

Reading

S

Z

CS

AC

Ohm

Power

200mV

2V

20V

20V

1000V

Normal

Scaled (specify value)

Offset (specify value)

Internal current shunt (specify range)

AC reading

Ohms reading

5VDC ±5%, 200mA

12VDC

24VDC

28VDC

18-34VDC isolated

120VAC

240VAC

Rin

100MΩ (RM3xx only)

1000MΩ

1MΩ

10MΩ

10MΩ

36

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Martel

Digital Panel Meters

900 Series

• LED or Backlit LCD

• Large 0.75” Digit Height

• ±200mV A/D

• IP67/NEMA 4X

Bezel Option

DPM950

DPM959

700 Series

1 /

2

" (or 2 x

1 /

4

")

Digit Height

• LED Backlight

• ±200mV A/D

• IP67/NEMA 4X

Bezel Option^

DPM750S

DPM702S

Dimensions:

Panel Cut-out:

Operating Temp:

LCD Backlight:

SPECIFICATIONS

2.99" x 1.73” x 0.51"

(76.0 x 44.0 x 15.0mm)

2.83" x 1.57” (72.0 x 40.0mm)

0°C to 50°C

50mA@5V (except DPM942)

ORDERING INFORMATION

Model Function Accuracy ±1d Supply VDC

DPM950

DPM950S

DPM595B

DCV*

DCV*

DCV*

DPM942

DPM970

4-20mA

ACV*

DTM910 °C/°F (Pt100 RTD)

DTM995 °C (Type K TC)

±0.05%

±0.05%

±0.05%

±0.05%

0.5%

1°C

1%

7.5-14

3.5-6.5

4.5-5.5

loop pwr

7.5-14

4.5-5.5

7.5-24

*Specify input range or internal shunt for current measurement.

37

35/65 Series

• Red LED, Green LED or LCD

• Voltage or Process Inputs

• Display Hold

• 5V power

35X

35x Dimensions:

35x Panel Cut-out:

35x Mounting:

65x Dimensions:

65x Panel Cut-out:

65x Mounting:

Digit Height:

Accuracy:

Operating Temp:

Power:

DPM35R

DPM35G

DPM65

DPM65S

SPECIFICATIONS

2.57" x 1.10” x 0.77"

(64.0 x 28.0 x 16.8mm)

2.05" x 0.81” (52.1 x 20.6mm)

Window or bezel

2.3" x 1.1” x 0.71" (59 x 29 x 18.1mm)

2.22" x 1.04” (56.5 x 26.5mm)

Snap-in bezel

0.56" LED, 0.39" LCD

±0.05% ±1d typ.

0°C to 50°C

5VDC ±5%

ORDERING INFORMATION

Red LED DPM, differential input

Green LED DPM, differential input

LCD DPM, differential input

LCD DPM, single-ended input

-BL Dimensions:

-BL Panel Cut-out:

702S Dimensions:

702S Panel Cut-out:

Operating Temp:

LCD Backlight:

SPECIFICATIONS

2.57" x 1.39” x 1.36"

(65.2 x 35.2 x 32.0mm)

2.38" x 1.20” (60.5 x 30.5mm)

2.54" x 1.36” x 0.45"

(64.5 x 34.5 x 11.5mm)

2.44" x 1.26” (62.0 x 32.0mm)

0°C to 50°C

30mA@5V (except DPM702S)

ORDERING INFORMATION

Model

DPM750S-BL

DPM702S

DPM742-BL

Function

DCV*

DCV*

4-20mA

Accuracy ±1d

±0.1%

±0.05%

±0.1%

Supply VDC

3-15

3.5-7 loop pwr

*Specify input range or internal shunt for current measurement.

^IP67 bezel not available on DPM702S

EM32 Series

• 0.31" Digit Height

• Metal Bezel

• Mounts in 32.5mm

(1.28") Cutout

• IP67/NEMA 4X Front

Dimensions:

Accuracy:

Input:

Operating Temp:

Power:

EM32

SPECIFICATIONS

1.5" dia x 0.93" (38.0 x 23.5mm) excluding pins

±0.1% ±1d typ.

±200mV DC*

0°C to 50°C

5VDC ±5% @500mA (50ma for LED)

ORDERING INFORMATION

EM32-1B

EM32-1B-LED

Circular LCD DPM

Circular LED DPM

*Specify other ranges or internal shunt for current measurement.

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Martel

Quick Mount Digital Panel Meters

QM130M—

Digital Wiper

Type DC Voltmeter

• 9 Segment LCD

• Color Scale

• Single Hole Mounting

QM100V—

2-Wire Voltmeter

• Monitoring of Voltage Systems

• 2-Wire Operation

• Reverse Polarity Protection

Easy to mount LCD Digital Panel

Meter ideal for monitoring 4 to 25 volt DC systems.

Low cost meter for when order of magnitude of the reading is more important that the value of the reading.

QM130M

SPECIFICATIONS AND ORDERING INFORMATION

Full Scale Reading:

Resolution:

Supply Voltage:

Supply Current:

1 VDC

125 mVDC

5–12 VDC

1.5 mA

QM100V

SPECIFICATIONS AND ORDERING INFORMATION

Input:

Accuracy:

Voltage Supply:

Current Supply:

QMV100

4.0 to 25.0 VDC

0.2% ± 1 count

3–50 VDC

3 mA

QMV100-40

4.0 to 40.0 VDC

0.4V ± 1 count

3-50 VDC

3mA

QM120C—

Elapsed Time Meter

• 9999.9 and 99999 Hour Ranges

• Reset and Trip/Total Inputs

• Leading Zero Blanking Input

• Pulse Output every 100 Hours

Easy to mount LCD digital elapsed hour meter which starts timing the moment it is powered up.

QM120C

SPECIFICATIONS AND ORDERING INFORMATION

Resolution:

Operating Temp:

Supply Voltage:

Supply Current:

9999.9

99999

0–50°C

5–27 VDC

2.5 mA

0.1 hr

1.0 hr

QM140V— Voltage/Current Meter

• 200 mV Full Scale Reading

• Auto-zero, Auto-polarity

• Low Battery Warning

• Optional Screw Terminal Board

This model features 200 mV full scale input that can be configured to accept voltage up to 20 VDC and current up to 200 mA.

QM140V

SPECIFICATIONS AND ORDERING INFORMATION

Input:

Accuracy:

Supply Voltage:

Supply Current:

200 mV, 2V, 20V

200 µA, 2 mA, 20 mA, 200 mA

0.05% ±1 count

7.5 to 15 VDC

150 µA

QM110T— Temperature Meter

• Internal Temperature Sensor

• 0.5" LCD Digit Height

• Readings in Degrees C or F

A digital temperature indicator with an internal temperature sensor or wire it for external sensors.

QM110T

SPECIFICATIONS AND ORDERING INFORMATION

Measuring Range:

Resolution:

Supply Voltage:

Internal Sensor

-10 to +50°C

-14 to +122°F

0.5°C

4–28 VDC

External Sensor

-20 to 220°C

-4 to 428°F

1°C

4–28 VDC

SPECIFICATIONS FOR ALL METERS

Character Height: 0.5" (12.5mm) except

0.35°(9mm) on QM120C

Operating Temperature: 0-50°C

Dimensions (W x H): 1.71" (43.50 mm) x 0.84" (21.40 mm)

Mounting:

Sealing:

7/32" (5.5 mm) hole

IP65 Front

38

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Weschler

Large Display Meters

• NEMA 4 Sealed

• Clear, Bright Display

• Remote Scaling and Brightness Setting

• Accepts Analog Signals Directly

• Fully Scalable, Includes Excitation

• Completely Self-Contained

• Serial Data O/P as Standard

SPECIFICATIONS

Standard Inputs

Scalable Inputs:

Excitation Supply:

Power Requirements

Standard Supply:

Optional Supply:

4–20 mA, 0–20 mA, 0–10V, 1V–5V

12.5 VDC @ up to 60 mA

95V–265V, DC to 400 Hz (20 watts)

12V–26V, DC to 400 Hz

ORDERING INFORMATION—ACCESSORIES

1700RP

DCPSU

RTD

TC

Remote Contact Closure Programmer

24 VDC Power Supply

3-Wire RTD Input**

Thermocouple Input Type K**

Weschler

Large Displays

A simple and affordable way to see and share important measurements over large distances:

2" (57mm) digits for viewing up to 65ft (20m)

4" (102mm) digits for viewing up to 130ft (40m)

Available in 3 input types, these meters can be configured from the front panel.

ER

P1700

NEW

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: P1758-B-1-0-21

A – B – C – D – E

A

B

C

D

E

21

20

23

24

Basic Unit

P1752

P1754

P1756

2" Digits

4" Digits

6" Digits

P1758 8" Digits

P17511 11" Digits

Case Color

B

W

Mounting

Black

White

1

2

3

Display

Panel

Wall

Suspension

0

DLV

Input Range

Normal Viewing

Daylight Viewing

4–20 mADC

0–20 mADC

0–10 VDC

1–5 VDC

ORDERING INFORMATION

A

B

C

To Order—Insert Number Code for Each Letter to

Select Catalog Number. Example ER4P-2

ER A B – C

Digit Size

2

4

C

S

Type

P

Mounting

2

3

2"

4"

Process Input

Count/rate Input

Slave

Wall

Suspension

39

Process (Type P)

Input:

Accuracy:

Display by:

Count (Type C)

Input:

Accuracy:

Slave (Type S)

Input:

Format:

Addressing:

4-20mA, 0-10V, 1-5V, scalable

±0.1% range ±1d @25°C

1, 2, 5, 10, 20, 50

NPN, PNP or contact closure

±0.05% range ±1d @25°C

RS232, RS422, RS485 or TTY

ASCII data from 300-9600 baud

00 to FF

SPECIFICATIONS

Reset:

Excitation:

Sealing:

Front panel or remote contact closure

24VDC, up to 30mA (except Slave)

Operating Temperature: 0-50°C, <95% RH non-condensing

Power: 95-265VAC, 11-30VDC

Dimensions: ER2 10.3x5.8x1.8" (260x140x45mm)

ER4 16.4x7.7x1.8" (415x195x45mm)

IP54 dust tight

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Newport

Two-Wire Loop-Powered Process Indicators

• Powered by 1–5 mA, 4–20 mA, or 10–50 mA Signal

• 2.5V Max Voltage Drop

• Display to ±1,999, ±19,990 or ±199,900

• 0.5" (12.7 mm) LCD

• 100 to 2,000 Count Span Adjust

• 2,000 Count Zero Suppression or Elevation

• Short 1/8 DIN Case

• Simple 2-Wire Hook Up

• Intrinsic Safety Certification (Optional)

• -40 to +85°C Operating Temperature (Optional)

558B

Made in the USA, these Newport LCD indicators provide extensive zero and span adjustment capability, so the units can read out directly in percent or in engineering units for process variables such as pressure, flow, temperature, or level. The liquid crystal display provides 3 1

/

2 active digits, two-jumper selectable dummy right hand zeroes, and five programmable decimal points.

The 508B series, in the NEMA-4 die-cast metal housing, is weatherproof to 5 PSI, with a temperature range of -40°C to

+85°C. The popular 558B series fits a 1/8 DIN panel cutout.

Electrical connections are via a three-pole male header connector on the circuit board and a removable mating plug-in socket connector with screw clamps, allowing for easy and reliable electrical connections.

FM

2P1A7.AX

558B

558B-ET

558B-IS1

ORDERING INFORMATION

Current Loop Indicator

Current Loop Indicator with Extended

Ambient Range (-40 to 85°C)

Intrinsic Safety Certification with

CENELEC EEx Label

Accessories

SPC18

SPC4

NEMA-4 Splash Proof Lens Cover

NEMA-4 Heavy Duty Splash Proof Lens Cover with Screw Clamp

Martel

Loop Powered Process Indicators

LPM4200P

• 3

1

/

2

digit LCD Display

• Large 1 Inch Digits

• NEMA 4 & Panel Mount Enclosures

The LPM4200 Loop Powered Indicators are ideal for areas where local readout of a process variable is required and ease of viewing is important. Powered by the 4 to 20 mA loop, they drop only 2.7 volts from the loop being monitored. These meters are easy to install and can be scaled to read directly in the engineering units desired.

SPECIFICATIONS

Input:

Readout:

4-20 mA DC typical

3

1

/

2

digit LCD Display with switchable dummy zero

Decimal Point: Position is switch selectable

Accuracy: ±0.05% of full scale ±1 count

Span Range:

Zero Range:

100 to 2500 counts, switch selectable

±500 counts

Stability: 0.01%/°C

Temperature: Operating -20 to 70°C

Storage -30 to 80°C

Voltage Drop: 2.7V DC max.

Size:

NEMA 4

Panel Mount

6.3" W x 3.15" H x 3.15" D

5.67" W x 2.83" H x 2.83" D

(panel cutout 5.42" x 2.60")

ORDERING INFORMATION

LPM-4200N Loop Powered Indicator, NEMA 4

Enclosure

LPM-4200P Loop Powered Indicator, Panel Mount

Enclosure

40

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Weschler

DC Loop Powered Meters

• Powered Entirely from the Input Signal

• High Contrast LCD Display

• Clear Visibility in Direct Sunlight

• 1/8 DIN Case

• Detachable Screw Terminal Connectors

• Wide Ranging Zero and Span Control

• Selectable Decimal Point Location

• Simple to Install

• Low Cost

• X10 and X100 Add-On Zeros (Jumper Selectable)

Input Ranges:

Display Type:

Display Height:

Decimal Points:

Power Voltage:

Power Consumption:

CMRR:

Size:

Weight:

Case Material:

Operating Temperature:

Storage Temperature:

Relative Humidity:

SPECIFICATIONS

2-wire connection, 4 mA–20 mADC,

125Ω

10 mA–50 mADC, 50Ω, 1 mA–5 mADC

7-segment, HI-C LCD

12.7 mm 0.50"

Selectable internally

Line drop <2.5V DC

100 mW maximum

65 dB, DC to 450 Hz

1/8 DIN panel area and cutout

150 grams typically

94V–0 UL polycarbonate

-10°C to 50°C

-40°C to 85°C

Non-condensing 90% maximum @ 40°C

PRO

88-PRO

The 88-PRO is a low-cost, 3 1

/

2

-digit, scalable, process input indicator. It has an easy-to-read LCD display and detachable screw terminals. The basic 3 1

/

2

-digit offers 0 to 1,999 display range. This can be extended to 0 to 199,900 with both add-on zeroes enabled.

88-PRO

ORDERING INFORMATION

3 1 ⁄

2-

Digit Loop Powered Meter

41

Monarch

Panel Tachometers and Totalizer

ACT Series

ACT-1B

• Universal Input from Optical, Infrared, Proximity and

Magnetic Sensors

• Direct TTL and 200 mV to 50 VAC Input Signals

• Selection of Sensors For All Environments

The ACT tachometers offer a simple RPM display or can be interfaced with data acquisition systems in your control room.

The ACT-1B/115 operates from a single pulse per revolution.

ACT-3/115 is front panel programmable for single or multiple pulses per revolution and for scaling. The ACT-3 is supplied with

NIST CERTIFICATE and has 2 alarm set points, offset analog voltage, current, TTL pulse and RS-232 outputs and offers a counter (totalizer) mode.

Speed Range

Accuracy

Display

Totalizer

Alarm Capability

Analog Outputs

Pulse Repeater

Dimensions

SPECIFICATIONS

ACT-1B/115

5 to 100,000 RPM

1 RPM

.56" H red LED

N/A

N/A

N/A

N/A

1/8 DIN by 4.5" deep

ACT-3/115

5 to 999,99 RPM

.001%, .0001 to 10 RPM

.56" H red LED

1-99,999

Two alarm set points. Front panel programmable as high or low.

Voltage(0–5 VDC), Current (4–20 mA)

Pulse Output,0–5V TTL compatible

1/8 DIN by 7" deep.

Compatible speed sensors on page 115

ACT-3/115

ACT-1B/115

ORDERING INFORMATION

Tach/Totalizer

Tach (1 Pulse/Rev)

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Laurel

Programmable Counters

FUNCTIONS

• Rate, Frequency, Period

• Total, Up/Down Total, Batch

• Time Interval, Stopwatch

• Quadrature

• Ratio / Draw

• Batch Controller

• Integrating Totalizer

• Phase Angle & Duty Cycle

FEATURES

• ±999,999 Display Span

• Scaling in Engineering Units

• Crystal Time Base Error <0.001%

• Sensor Excitation Output

• 1/8 DIN, NEMA-4X Front Panel

OPTIONS (all outputs isolated)

• Dual Setpoint Controls Output

• Analog Transmitter Outputs

• RS-232 & RS-485 Data I/O

• Custom Curve Linearization

• Datalogging PC Software

Exceptional flexibility is provided by advanced programmable features and by modular architecture with a choice of main boards

(basic or extended), signal conditioners (FR, VF or QD), power supplies, analog output, relay outputs, and data I/O.

SPECIFICATIONS

Display

Conversion Technique

Frequency measurement technique

Rate

Gate time

Scale Factor

Isolation

FR Signal Conditioner

Inputs

Channel A frequency

Channel B frequency

VF Signal Conditioner

Inputs

Span error

Span tempco

Zero tempco

QD Signal Conditioner

Six 14.2 mm (.56") high LED digits

1/period

Gate time + 30 ms + 2 input periods

Selectable 0 to 199.99 sec

±10 -10 to ±10 6

4.2 kVp (DC to 60 Hz)

AC, pulses from NPN or PNP transistors, contact closures, magnetic pickups

0 Hz to 1 MHz

0 Hz to 250 kHz

0-10 V, 0-1 mA, 4-20 mA

< 0.015% of full scale ±1 count

< 0.003% of reading/°C

< 0.001% of full scale/°C

Quadrature encoders to 250 kHz

Differential or single-ended

Zero index (Z-channel)

Inputs

Polarity

Error correction

Transducer Excitation Output (std)

Output

Isolation

Data Communications (opt)

RS-232

RS-485

BCD

Operating Temperature

5V, 100 mA; 10V, 120 mA; 24V, 50 mA

4.2 kVp per high voltage test

Full Duplex

Half or full duplex

6 decades parallel

0°C to 55°C

ORDERING INFORMATION

Example: L50010FR

L

Laureate ™

Main Board

5 with plug-in screw terminal connectors

Meter with green LEDs

6

7

Meter with red LEDs

Extended, green LEDs

8

Power

0

Extended, red LEDs

85-264 Vac/90-370 Vdc

1 9-37 Vdc/8-28 Vac

Setpoint Output

0 None

1 Dual 10 A relays

2 Dual solid state relays

Analog Output or Batch Relay

0 None

1 0-20 mA, 0-10 V

2 Batch relay for FR

Digital Interface

0 None

1

2

RS-232

RS-485

3

Input Type

FR

BCD output

Frequency

With main boards 5 & 6: V-to-F converter for rate or square root of rate from different pressure or target type flow meters. With main boards

7 & 8: Above plus rate and total simultaneously, linearization of nonlinear inputs, ratio, draw, arithmetic functions (A*B, A/B, A/B-1, A+B, A-B), phase angle, stopwatch, up/down counting, batch counting.

With main boards 5 & 6: V-to-F converter for rate or square root of rate from differential pressure or target type flow meters. With main boards

7 & 8: Above plus rate and total simultaneously, linearization of nonlinear inputs, batch counting, 1/rate (time).

QD Quadrature

With main boards 5 & 6: Scalable to ±999,999 to read out position or length from shaft encoders.

QDR Quadrature Rate

With main boards 5 & 6; Scalable to ±999,999 to read out rate from shaft encoders.

42

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

Simpson

1/8 DIN Counter Totalizer, Rate/Totalizer/Batch

43

S664

• NEMA-4X Front Panel

• Four Frequency Ranges Available (99 Hz, 999 Hz,

9 kHz, 35 kHz)

• Easy to Use (Install/Wire/Mount, Select Range, and Go)

• Bright Red LEDs for Easy Viewing

• Minimum Mounting Depth Required

• 120 or 240 VAC

• Optional Excitation Output 12 VDC @ 100 mA

• Modular Design

• Screw Terminals for Easy Installation

Display Type:

Power:

Operating Temp:

Size:

SPECIFICATIONS

7 segment, bright red LED, 0.56" H

120/240 VAC

0 to 55°C

3.6" W x 1.8" H x 3.24" D (92 x 48 x 82 mm)

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select

Catalog Number. Order Example: S664-1-1-0-0-0

A – B – C – D – E

F

A

B

C

D

E

F

Basic Unit

S664

Power Supply

1

2

Input Type

Frequency Counter

120 VAC

220 VAC

1

2

Standard Pulse Input

Quadrature input

Output Type

0 None

Excitation Output

0

1

None

12 VDC

Other

0 None

S660

• NEMA-4X Front Panel

• Uses Words, Not Symbols for Easier Programming

• Bright Red LEDs for Easy Viewing

• Large, Tactile Buttons Can Be Pressed with Gloves On

• Standard 1/8 DIN Cutout

• Up to Two 5 Amp Relays Optional

• Optional Excitation Output 12 VDC

• Screw Terminals for Easy Installation

Display Type:

Power:

Operating Temp:

NMRR:

Size:

SPECIFICATIONS

7 segment, bright red LED, 0.56" H

120/240 VAC

0 to 55°C

60 dB @ 50/60 Hz

3.6" W x 1.8" H x 3.24" D (92 x 48 x 82 mm)

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select

Catalog Number. Order Example: S660-1-2-2-1-0

A – B – C – D – E

– F

A

B

C

D

E

F

Basic Unit

S660 Preset Up/Down Counter

S661 Preset Rate Counter

S662 Preset Totalizing/Batch Counter

S663 Preset Totalizing/Rate Counter

Power Supply

1

2

Input Type

120 VAC

220 VAC

1

2

Standard Pulse Input

Quadrature

Output Type

0

1

0

1

2

None

1 Mechanical Relay

2 Mechanical Relays

Excitation Output

None

12 VDC

Other

0 None

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

ATC Westcon

Counters

W3830 Series

6-Digit Indicator/Totalizer with Optional Outputs

W3870 Series

6-Digit Frequency Input Indicator/Totalizer with Optional Outputs

FEATURES

• Automatic Square Root

Extraction

• Logic Controlled Up/Down

Counter

• Preset Up Counter

• Preset Down Counter

• FLUME 5/2 Calculation

• WEIR 3/2 Calculation

SPECIFICATIONS

MODEL: RANGE: ACCURACY:

3830-23

3830-25

3830-27

0-5 VDC

0-10 VDC

4-20 mA

±0.08% reading, ±0.05% FS

±0.08% reading, ±0.05% FS

±0.08% reading, ±0.05% FS

OPERATING TEMP: 0°C to 50°C (32°F to 122°F)

FRONT COVER:

NEMA 4

CASE:

Anodized Aluminum

OPTIONAL OUTPUTS

OPTION C: 3 Form-C 5 amp relay outputs activate when

programmable high and low limits are exceeded.

Permits on-off control of external circuitry, or alarm status communication with other equipment.

OPTION H: 4 analog outputs, 0-5 VDC, ±5 VDC or 4-20 mA.

Accuracy is 0.35% of scaled range. Output signals are proportional to meter display.

OPTION T:

RS232C serial data communications interface at

9600 Baud rate.

OPTION V:

Totalizer pulse output. Solid-state relay (SSR).

Operating range: ±80V peak. continuous load current:

150 mA. Pulse width: 60mS (consult factory if faster output is required).

ORDERING INFORMATION

Model #:

Input

23

25

27

3830

0-5 VDC

0-10 VDC

4-20 mA

XX

Options

C

H

T

V

3 Relays

Analog

RS232

Totalizer Pulse Output

X X X X

SPECIFICATIONS

RANGE: User programmable

decimal, scale factors and insignificant zero blanking yield a display range of 0.00001 to

999999.

INPUT RESPONSE:

0.0005 to 99,999 Hz

PROTECTION: ±200 V peak

SENSITIVITY: TTL, CMOS or

contact compatible

PULSE WIDTH: 5 micro- seconds

minimum

TRIGGER MODE: Negative edge

of input pulse

INPUT IMPEDANCE: 12k ohms

FILTER/DEBOUNCE:

Front panel programmable digital filter

OPTIONAL OUTPUTS

Option C:

3 Form-C 5 amp relays activate when programmable high and low limits are exceeded. Permits on-off control of external circuitry, or alarm status communication with other equipment.

Option G:

Input amplifier, 30 mV peak input at 5 Hz to 99,999 Hz.

Option H:

4 analog outputs, 0-5 VDC, ±5 VDC or 4-20 mA. Accuracy is 0.35% of operating range. Output signals are assignable to rate and total.

Option S:

230 VAC Power.

Option T:

RS232C serial data communications interface at 9600

Baud rate.

Option X:

Screw terminal block connector. Accepts up to

#14 AWG wire.

ORDERING INFORMATION

PRICE

$ 225

Model #:

3870 X X X X X X

$ 60

65

140

N/C

60

26

Options

C

G

H

S

T

X

Relay Outputs

Input Amplifier

Analog Outputs

230 VAC Powered

RS232

Screw Terminal

44

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

KEP

Counter/Timer

KAL-DIN Series

KALD—8-Digit Counter

KALDTIME—7-Digit Timer

KALDRT—6-Digit Totalizer and 5-Digit Ratemeter

• UL, CSA Listed, CE Certified

• Meets NEMA-4X and IP65 Ratings

• Long Life Lithium Battery (KALD and KALDTIME only)

• Remote and Front Panel Reset

• Plug-On Adapter with Terminal Block and

AC Pulsing (KALD and KALDTIME only)

• Slow Speed Input for Contact Closures

• High Speed Input for Sinking Inputs from a

Max. of 24 VDC Without Module

The KAL-DIN series offers Count, Time, and Rate indication in a compact package. The KALD Counter and KALDTIME timer are self powered with an internal lithium battery. The KALDRT offers a 5-digit ratemeter and a

6-digit counter.

Digit Size:

Dimensions:

Panel Cutout:

Temp. Range:

Approvals: proved

SPECIFICATIONS

0.276" (7mm) high

1.89" W x 0.944" H x 1.36"D

(48 mm x 24 mm x 34.5 mm)

1.771" W x 0.886" H (45 x 22.5 mm)

14 to 140°F (-10 to 60°C)

UL File: E135458, CSA File: LR9602, CE Ap-

Weight:

Connection:

Sealing:

Power:

KALD:

KALDTIME:

KALDRT:

Display:

1.7 oz (48.2g)

5-pin, plug in connector with 9" (229 mm) leads supplied. Optional snap-on adaptors available

NEMA-4X/IP65

Internal lithium battery (life 10 yrs calculated)

Internal lithium battery (life 8 yrs calculated)

10 to 30 VDC, 10 mA

KALD

KALDTIME

KALDRT:

Signal Inputs:

Slow Speed Input:

High Speed Input:

KALD:

KALDRT:

45

Accuracy:

KALD:

KALDTIME:

KALDRT:

Resolutions:

KALDTIME1:

KALDTIME2:

KALDRT:

5-digit rate, 6-digit count, black

Contact Closure; negative level active

Low: <0.7 VDC, high: 3 to 24 VDC

Input Impedance: 1 Mohm pull-up

Minimum pulse length 15 mS, 30 Hz maximum

Minimum pulse length 50 µS, 10 kHz maximum

Min. pulse length 1.5 mS, 333 Hz max.

(RPM mode)

Min. pulse length 10 µS, 50 kHz max.

(freq. mode)

100 % @ rated count speed

±.003 % @ 25°C

RPM: 0.18%, Freq.: ±1 LSD

Minutes and seconds or seconds only

Hours and 100ths or hours and minutes

RPM or frequency meter

KALDRT

KALD

KALDTIME1

KALDTIME2

KALDRT

ORDERING INFORMATION

8-Digit Counter

7-Digit Timer, Secs or Mins. and Secs

7-Digit Timer, Hrs and 100ths or Hrs and Mins

5-Digit Ratemeter with 6-Digit Totalizer

ACCESSORIES

KALDTB Terminal Block Adaptor

KALDAC/DC 5–240V AC/DC Input Adaptor for Counter

KALDTIMEAC/DC 5–240V AC/DC Input Adaptor for Timers

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

KEP

Counter/Timer

KEP

Totalizer/Rate Meter

Ratemeter/totalizer/process monitor from analog inputs

LCD preset add/subtract counter, timer, frequency meter

903K/904K Series

• 6-Digit Counter, Timer or

Frequency Meter

• 2 Preset Values

(Type 903K 1 Preset)

• Input Scaling

(0.0001 to 9.9999) Multiplier

• 2-Line LCD Display

• Count and Preset Range of -999999 to 999999

• Add or Subtract Count Control

• AC or DC Operation

• Secondary Preset Batch Counter (904K)

• 24 VDC to Power Peripherals

Display:

Preset:

SPECIFICATIONS

6-digit, 2-line, 7 segment LCD with sign

Type 904 two preset values

Type 903 one preset value

904K

INT69RT

Intellect-69 Series

• High/Low Scaling from Front Panel

• 2 Set Points Assignable To Rate or Total

• Display Rate (Pressure, Level, Watts, Etc.),

Peak and Valley and Integrated Total

• 0–5V, 0–10V, 1–5V, 4–20 mA or 0–20 mA Analog Input

• NEMA 4X/IP 65 Front Panel

• +24V Output for Peripherals

• RS-422/RS-232 Serial Communications

• 4–20 mA Output

• Square Root Extraction

• Optional Rate Per Day Feature

Supply voltage: 115 VAC, 230 VAC, 48 VAC or 24 VAC

Housing:

(tolerance ± 10%) or 11 to 30 VDC

48 x 48 mm DIN

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: INT69RT-A-L-1-A-C1

Protection: IP 65 (front)

A – B – C – D – E

Power Supply:

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number

Order Example: 904K-A-0-A

A – B – C – D

A

B

C

D

24 VDC, 80 mA

Basic Unit

903K Single Output

904K Dual Outputs

Input Voltage

A 115 VAC

D

E

B

C

Outputs

230 VAC

11 to 30 VDC

24 VAC

48 VAC

0

1

Options

A

Relay

Opto-Isolated collector and emitter

Blank if None

Backlit LCD Display (904K only)

A

B

C

D

E

Basic Unit

INT69RT Ratemeter/Totalizer

INT69R Ratemeter Only

INT69PM2 Process Monitor

A

B

INT69T

Displays from -19999 to +49999

Totalizer Only

Operating Voltage

110 VAC ±15% or 12 to 24 VDC

220 VAC ±15% or 12 to 24 VDC

L

S

Inputs

— Blank for INT69PM2

Linear (standard)

Square Law (optional)

A

D

C1

C2

Control Outputs

1 2-Open Collector Outputs (standard)

2 2–10 Amp Form C Relays (optional)

Options (Multiple Options Available)

Analog Output (4–20 mA)

Rate per Day, Hour or Minute

RS-232 communications

RS-422 communications

46

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]

WESCHLER INSTRUMENTS

KEP

Totalizer/Rate Meter

Low Cost, Pulse Input,

Totalizer & Ratemeter

Newport

6-Digit Rate Meter/Totalizer

6-digit ratemeter/totalizer offers user programming via the 5 front-panel keys. Scale factor may be programmed from -99,999 to 999,999 (any decimal point, multiply or divide), while offset may be programmed from -99,999 to

999,999 (any decimal point).

Programs are stored in non-volatile memory, with three levels of program lockout for security.

INFCTRA

Optional features include Hi or Lo setpoints for control or alarm, plus

RS-232 communication. Fixed decimal point or autoranging is standard.

MINItrol Series

• CSA Approved

• Separate Scaling Factors for A and B Inputs

• Display Rate and Total

• Pulse Input—10 kHz Maximum

• Security Lockout

• RS-422/RS-232 Serial Communication

• NEMA-4X/IP65 Front Panel

• Separate Add/Subtract Simultaneous Inputs

• Quadrature and U/D Direction Control Inputs

• 30 mV Magnetic Pickup Inputs

• 4–20 mA or 0–20 mA Analog Output

MRT

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number.

Order Example: MRT-A-3-1

A – B – C – D

Functions:

Display:

Inputs

Type:

Level:

Frequency:

Excitation:

Accuracy:

Setpoints:

Alarm Outputs:

Communication:

Power:

Dimensions/Weight:

SPECIFICATIONS

Rate and totalize selected by menu

6-digit, 7-segment red LED display

ORDERING INFORMATION

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order

Example: INFCTRA-0-1-1-0-R

Basic Unit

INFCTRA

Power and Display

0 115 VAC, Red LED

1 230 VAC, Red LED

2

3

115 VAC, Green LED

230 VAC, Green LED

Control Output

0 None

1 Dual 6 Amp

Analog Output

0 None

1 Analog Output

Serial Output

0 None

R

T

1 RS-232

Configuration

Ratemeter

Totalizer

Single input. TTL, CMOS, NPN open collector, contact closure and magnetic pickup compatible; selected by dip switch. Non-isolated

Max. 60V; min. 25 mV rms

30 kHz maximum

Regulated, 5.0, 8.2, or 12.5V selected by DIP switch, 100 mA max

± 1

/

2

LSD of total; 0.01% of the rate ± 1

/

2

LSD

Two, optional

Optional

RS-232, analog output, optional

230 ±15% VAC

1.9" H x 3.8" W x 6" D

(48 x 96 x 152 mm)/16 oz (454g)

1.8" H x 3.6" W (45 x 92 mm)

47

A Basic Unit

MRT 6-Digits, Counter/Ratemeter

MC2

MR2

6-Digits, Counter Only

5-Digits, Rate Only

B Operating Voltage

A 110 VAC ±15% or 12 to 15 VDC

B

C

220 VAC ±15% or 12 to 15 VDC

24 VAC ±15% or 12 to 15 VDC

C Count Inputs

3

3M

3MB

5

5M

9

Standard, 4–30 VDC Simultaneous Inputs

Mag. Input, Input A Only,

30mV Input (Input B, 4–30V)

Mag. Input, Inputs A and B, 30 mV input

4–30V Pulses on Input A,

4–30V Direction Control Input on Input B

30 mV Pulses on Input A,

4–30V Direction Control Input on Input B

Quadrature, Accepts 4–30V Pulses

9MB Quadrature, Accepts 30 mV Pulses (A and B)

D Control Outputs

1

2

RS-232 Communications

RS-422 Communications

A

CE

Analog Output (4–20/0–20 mA)

CE Approved Version

NOTE: RS-232/RS-422 and analog output options can not be combined.

Panel Cutout:

A – B – C – D – E

– F

D

A

B

C

E

F

WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]