advertisement
WESCHLER INSTRUMENTS
Newport
Digital Indicator Controllers
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: Q2001-CVR6
A
A
B
C
D
E
F
B C D – E F
Display Resolution and Case Style
Q2 ±1999 Counts (3 1 ⁄
2
-digits)
Q3 ±1999 with “Infinity
™
Family Bezel and Adapter”
Q9 ±9999 Counts (4-digits)
Q8 ±9999 with “Infinity
™
Family Bezel and Adapter”
Display Type and Meter Power
4
6
0
2
8
LED, 120 VAC (49/440 Hz) (BQ20 or BQ90)
LED, 240 VAC (49/440 Hz) (BQ22 or BQ92)
LED, 9–32 VDC (isolated) (BQ24 or BQ94)
LED, 5 VDC** (BQ26 or BQ96)
LED, 24 VAC (BQ28 or BQ98)
A LED, 26-–56 VDC (isolated) (BQ2A or BQ9A)
**Not available with AC AVG or True RMS inputs
Analog Output Adders
4
6
2
3
Max one analog output in addition to recorder output
0 ±1 or ±2 V recorder output, non-isolated
1 0–5 VDC, non-isolated (BA01)
0–10 VDC, non-isolated (BA01)
0–1 mA, source or sink, non-isolated (BA01)
4–20 mA, source or sink, non-isolated (BA01)
4–20 mA, isolated (BA03)
1
4
Control Output Adders
0 None
Dual-Setpoint 10A Relay (BDT1)
BCD (BDD2)
5 Single-Setpoint 10A Relay (BDS1)
Signal Conditioning Input Adders
❑
Select from Input Table
Green LEDs for Display
G Green
0 None
11
INPUT TABLE
Code Q2000/Q3000
DC Voltage Input
AVR1 ±199.9 mV
AVR2
AVR3
AVR4
±1.999V
±19.99V
±199.9V
DC Current Input
BCR1 ±19.99 µA
BCR2
BCR3
BCR4
BCR5
BCR6 ±1.999A
AC AVG Voltage Input
CVR2 199.9 mV
CVR3
CVR4
CVR5
1.999V
19.99V
199.9V
CVR6 650V
AC AVG Current Input
DCR1 19.99 µA
DCR2
DCR3
DCR4
±199.9 µA
±1.999 mA
±19.99 mA
±199.9 mA
199.9 µA
1.999 mA
19.99 mA
Q8000/Q9000
±99.99 mV
±999.9 mV
±9.999V
±99.99V
±9.999 µA
±99.99 µA
±999.9 µA
±9.999 mA
±99.99 mA
±999.9 mA
99.99 mV
999.9 mV
9.999V
99.99V
650.0V
9.999 µA
99.99 µA
999.9 µA
9.999 mA
DCR5
DCR6
199.9 mA
1.999A
99.99 mA
999.9 mA
DCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000,
(4) 5A = 300, (5) 5A = 500
Quanta® Standard Features
• Field Selectable Input Ranges
• Recorder Analog Output
• Front-Panel Accessible
Span Adjustment
• Bright, 0.56"
(14.2 mm) LED Display
• Display Hold and Test
• Screw-Terminal Barrier Strip
• Optional Relay Outputs
• 1⁄8 DIN Case
Options
• Analog Output for
User-Selected Span
• Single-Setpoint 10A
SPDT Relay
• Dual-Setpoint with Two
10A SPDT Relays
• Parallel BCD Output,
Isolated
Quanta
▲
INPUT TABLE (CONT’D)
Code Q2000/Q3000
True-RMS Voltage Input
FVR2
FVR3
199.9 mV
1.999V
FVR4
FVR5
19.99V
199.9V
FVR6 650V
True-RMS Current Input
GCR1
GCR2
GCR3
GCR4
GCR5
19.99 µA
199.9 µA
1.999 mA
19.99 mA
199.9 mA
Q8000/Q9000
99.99 mV
999.9 mV
9.999V
99.99V
650.0V
9.999 µA
99.99 µA
999.9 µA
9.999 mA
99.99 mA
GCR6 1.999A
999.9 mA
GCR7-(*) (1) 5A = 1000, (2) 5A = 1500, (3) 5A = 2000,
(4) 5A = 300, (5) 5A = 500
Frequency/Rate Input (100 mV Hystersis):
H 1000 Hz = 1000
Type J Thermocouple Input
1000 Hz = 0–9999
JDC1
JDF1
-40 to +760°C
-40 to +1400°F
Type K Thermocouple Input
KDC1 -40 to +1260°C
-40.0 to +760.0°C
-40.0 to +999.9°F
-40.0 to +999.9°C
-40.0 to +999.9°F KDF1 -40 to +1999°F
Type T Thermocouple Input
TDC1 -184 to +371°C -184.0 to +371.0°C
TDF1 -300 to +700°F -300.0 to +700.0°F
RTD (Pt 100) Input Alpha = 0.00385
MDC1
MDF1
-200 to +830°C
-328 to +1526°F
-200.0 to +830.0°C
-328.0 to +999.9°F
RTD Input, High Resolution Alpha = 0.00385
RDC1 -199.9 to +199.9°C Not available with Q8/Q9
RDF1 -199.9 to +199.9°F Not available with Q8/Q9
3-Wire Ratio Potentiometer Input
NPR1
NPR2
1000 = 1 kOhm
1000 = 5 kOhm
2- or 4-Wire Resistance Input
OOR1 19.99 Ohm
9999 = 1 kOhm
9999 = 5 kOhm
OOR2
OOR3
199.9 Ohm
1999 Ohm
Not available with Q8/Q9
Not available with Q8/Q9
Not available with Q8/Q9
OOR4 19.99 kOhm
Process Signal Input
Not available with Q8/Q9
P 4–20 mA = 0–100.0
4–20 mA = 0–99.99
Process Signal Input Excitation set to 15 VDC
E 4–20 mA = 0–100.0
4–20 mA = 0–99.99
Strain-Gage/Microvolt Input Excitation set to 10 VDC (30 mA max)
S ±100 mV = ±100.0
±100 mV = ±99.99
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Weschler
Quatro BarGraph Meters
• 101 segment bargraph in red, green or tricolor
• 4-digit 10000 count LED display
• 6" edgewise & 9/64 DIN cases
• Vertical or horizontal orientation
NEW
Features
• Single & dual bar configurations
• Adjustable bargraph span
• Bargraph center zero mode
• Four programmable setpoints
• Front panel setpoint status indicators
• Up to 4 relay outputs for control and alarms
• Analog retransmit option with adjustable span
• Wide power supply range (AC & DC)
• Sensor excitation to power 4-20mA transmitters or bridge type sensors
Direct Measurement of
DC Current
AC Current
DC Voltage
AC Voltage
Frequency
Process Loops
Thermocouples
RTDs
Load Cells/Strain Gauges
Speed Pickups/RPM
Pressure
Resistance/Potentiometers
Style A combines a precision 4 digit LED display with a 101 segment bargraph. The bar can be set to display any part of the digital range, from a minimum of 100 counts to the full 12000
A/D counts. Higher bar resolution is useful for applications where the normal operating range is only a portion of the full scale input. Style A offers 4 levels of display brightness, which can be set from the front panel.
▲
Style A
ORDERING INFORMATION
Select desired code for each category to buiId the 15 digit part number.
Example Part Number: MAVTRCXPD1AKXXX
Style C offers a 101 segment red, green or tricolor bar, without digital display. The bar can be set to grow from the bottom or the center of the scale. The center mode is normally used for center zero but can also show deviation around a half-scale value.
A B C D E G H I X X X
Style C
A Type
L 4 digit, 9/64 DIN Case
Input (Partial list continued)
M1 RPM, 99.99/999.9/9999Hz,
M 4 digit, 6" Edgewise Case
B Style
A Digital & bar
C Single bar (no digtial)
D Dual bar (no digital)
50mV-30V, w/24V Exc. (Style A)
PD Universal Process,
2V/5V/10V/20V/200V/2mA/20 mA/Custom
PE Dual Process,
The dual bar configuration (Style D) can display two process variables, using the Dual Process input card (PE). Any combination of red and green bars can be specified. Two setpoints are available for each channel. The dual input card may also be used to display
C Orientation
2V/10V/20V/200V/2mA/20mA
/Custom (style D only) one process variable on the left bar and two tracking setpoints on the right bar. In this mode, setpoint 1 is determined by the channel
V Vertical
H Horizontal RD Resistance, 2kΩ
SA Strain Gage, 5/10VDC Excitation,
Excitation, 20/2mV/V, 4-wire
TD Thermocouple, J Type (0-1400°F)
2 input signal. Setpoint 2 is offset from setpoint 1 by a fixed (user selectable) amount.
D Bar Color
R Red
G Green
T Tricolor (Style A or C only)
E Second Bar Color (right or bottom bar)
20/2mV/V, 4/6-wire
SD Pressure/Load Cell, 5/10V
▲
Style D
The dual bar style can be used with a single channel input module
& 4 set points. The left bar displays the process signal; the right bar displays min/max.
R Red (Style D only)
G Green (Style D only)
(Style C or D)
TE Thermocouple, K Type (0SPECIFICATIONS
X None
1999°F) (Style C or D)
F Input (Partial list)
AA AC Volts, scaled RMS, 200/600V
W1 Thermocouple, J,K,R,T; Selectable
°C/°F, 1°/0.1° (Style A)
Input Accuracy:
DCV, DCA ±(0.06% of reading + 2 counts)
AB AC Volts, scaled RMS,
200mV/2V/20V
W2 RTD, 100Ω Pt Selectable
3/4-wire, °C/°F, 1°/0.1°,
ACV, ACA
Temperature
±(0.07% of reading + 5 counts)
±(0.1% of reading + 3 counts)
G Power
385/392 (Style A)
Direct Pressure ±(1.0% of range + 3 counts)
AC AC mA, scaled RMS,
2/20/200mA
1 85-265VAC/95-370VDC
2 15-48VAC/10-72VDC
Frequency/RPM
Strain/Load
±(0.06% of reading + 2 counts)
±(0.08% of reading + 3 counts)
AD AC Amps, scaled RMS, 1 Amp
AE AC Amps, scaled RMS, 5 Amp
Process
Resistance/Pots
±(0.06% of reading + 2 counts)
±(0.06% of reading + 2 counts)
DE DC Volts, 2/20/200V/Custom
H Retransmit
w/Offset and 24V Excitation
DG DC Amps, 1A
A Isolated 16 Bit Current Output,
4-20mA
V Isolated 16 Bit Voltage Output,
0-10VDC
Bargraph Display: 4", 101 segment w/Offset and 24V Excitation
DF DC milliamp, 2/20/200mA
Bar Viewing Angle:
Digital Display:
Decimal Position:
±40° red or green, ±35° orange
4 digit LED, 0.31" (7.9mm) height
Range -1999 to 9999 counts
Front panel selectable n.nnn, nn.nn, nnn.n, nnnn.
DD DC Amps, 5A
E1 Line Frequency, 60-500VAC,
X None
I Relays
Relay Output:
199.9Hz, 400Hz optional
(Style C or D) for Type L:
2 Two 10A Form C
4 Two 10A Form C & Two 5A
Form A (SPST)
Form C (SPDT)
5A@250VAC, 5A@30VDC (resistive)
10A@240VAC, 8A@24VDC (resistive)
F2 Frequency,
99.99/999.9/9999Hz,
Form A **
Analog Output: Isolated 16 bit, user scalable
50mV-30V, w/24V Exc. (Style A)
X None mA out 4-20mA, 500Ω maximum loop resistance
F3 Frequency, for Type M:
Volts out 0-10VDC, 500Ω minimum load resistance
99.99/999.9/9999Hz,
B Two 10A Form C
Power Supply: 85-265 VAC / 95-370 VDC @2.5W (4.2W)
60-500VAC (Style A)
E Two 10A Form C & Two 5A
18-48 VAC / 10-72 VDC @ 2.5W (4.2W)
GF Direct Pressure, 15 psi differential Form A **
Sensor Excitation: 24V@50mA (2-wire loop power)
(clean, dry gas)
K Four 5A Form Al
10V@120mA (bridge excitation)
GH Direct Pressure, 30 psi X None
Operating Temperature: 0 to 60°C, 95% RH (non-condensing) differential (clean, dry gas)
** shared common between A & C
Click here for complete data & configuration information (pdf)
GK Direct Pressure, 100 psi differential (clean, dry gas)
12
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Weschler
Tri-Color Bargraph Meters
• Large, bright display with 16 step dimming
• 40 or 50 segment Tri-Color Bar
• Bar changes color at user adjustable setpoints —
Red, Green, Amber
• 5 digit resoluton
• Versatile selection of inputs
• Up to 4 form C relay outputs
• Peak/Valley option
• Trend indicator
• Analog retransmit option
• AC or DC power
• Rugged case
Sizes to replace popular edgewise and circular analog meters.
CONFIGURATION OPTIONS
SIZE
BG252
BH252
BV5A
BD101
BG241
BG281
6" Vertical BarGraph
6" Horizontal BarGraph
7 1
/
2
" Vertical BarGraph
10" Vertical BarGraph
4 1
/
2
" Square BarGraph
8" Circle BarGraph
POWER
120V AC 50/60Hz
240V AC 50/60Hz
12V DC
24V DC
28V DC
48V DC
125V DC
250V DC
120V AC / 125V DC
▲
BG261TC
INPUT
DC Volts
DC Amps
AC Volts RMS
AC Amps RMS
Line Frequency
MAG Pickup
Thermocouple
RTD
Watts
VARs
Power Factor
50mV to 250V full scale
50µA to 5A full scale
50mV to 250V full scale
1mA to 5A full scale
4-20mA DC
1-5V DC
10-50mA DC
55-65 Hz
50Hz-20kHz
J, K or T
100 ohm Pt or 10 ohm Cu
Single & polyphase
Over 4000 combinations available - Contact
Weschler to configure a Tri-Color BarGraph for your application.
COMMUNICATION
RS232
RS485
RETRANSMIT
4-20mA
0-1mA
1-5V DC
0-1V DC
10-50mA DC
Excitation Power 24 VDC
@ 90mA
DIGITAL DISPLAY
COLOR
Green
Amber
Red
BD101TC
13
FIELD PROGRAMMABLE FUNCTIONS
• Zero and full scale point location
•
Setpoint type (Hi or Low)
• Hysteresis & latching
• Setpoint time delay
•
16 step dimming
• Digital display for engineering units
•
Enable/disable front buttons
•
I.D. selection for communication
• Bar form
•
Peak / Valley enable
•
Color zones
• Over / Under range, flashing
•
Lamp test
▲
BH252TC
Click here for complete data & configuration information
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Weschler
Bargraph Meters
•
Large, bright display
•
101 segment bar, up to 10" high
•
3 1
/
2 or 4 1
/
2 digit resoluton
•
Versatile selection of inputs
•
Up to 4 form C relay outputs
•
Peak/Valley option
•
Analog retransmit option
•
AC or DC power
•
Rugged case
SIZE
BG252
BH252
PC101
PH101
PC202
PG202
BI1251
BW1316
BV5A
BD101
BG241
BG281
BG251
INPUT
DC Volts
DC Amps
AC Volts RMS
AC Amps RMS
Line Frequency
MAG Pickup
Thermocouple
RTD
Watts
VARs
Power Factor
CONFIGURATION OPTIONS
6" Vertical BarGraph
6" Horizontal BarGraph
DIN Size Vertical BarGraph
DIN Size Horizontal BarGraph
DIN Size Dual BarGraph
Dual BarGraph
6" Vertical BarGraph
6" Vertical BarGraph
7 1
/
2
" Vertical BarGraph
10" Vertical BarGraph
4 1
/
2
" Square BarGraph
POWER
120V AC 50/60Hz
240V AC 50/60Hz
5V DC
12V DC
24V DC
28V DC
48V DC
125V DC
250V DC
120V AC / 125V DC
8" Circle BarGraph
6" Circle BarGraph
SETPOINTS
Hi/Lo
Hi/Hi-Hi
Lo/Lo-Lo
Hi-Hi/Hi/Lo/Lo-Lo
50mV to 250V full scale
50µA to 5A full scale
50mV to 250V full scale
1mA to 5A full scale
4-20mA DC
1-5V DC
10-50mA DC
55-65 Hz
50Hz-20kHz
J, K or T
100 ohm Pt or 10 ohm Cu single & polyphase
COMMUNICATION
RS232
RS485
RETRANSMIT
4-20mA
0-1mA
1-5V DC
0-1V DC
10-50mA DC
Excitation Power 24 VDC
@ 90mA
LED COLOR
Green
Amber
Red
Over 4000 combinations available -
Contact Weschler to configure a
BarGraph for your application.
▲
BG241
PC202
▲
BG252
Click here for complete data & configuration information
14
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Dixson
Bargraph Meters/Controllers
15
• Fit Standard Switchboard Cutouts
• Red, Green or Amber LED Bar
• Precise 4 Digit Readout
• Underrange/Overrange Indication
• On/Off Control via Setpoint Relays
• Isolated Retransmit Option
• Transducer Excitation Supply
• Minimum 88,000 hour MTBF
• Two Year Warranty
SPECIFICATIONS
Input Ranges:
DC Volts
DC Current
AC Volts
AC Current
Thermocouple
RTD
DC Accuracy:
AC Accuracy:
Digital Display:
50mV to 250V
50mA to 250mA
250mV to 250V
1mA to 5A
J, K, T, E
Pt 100
±0.04% of span ±1d
±0.5% of span, above 5% of range
4 digit LED, 0.01% resolution
Enclosure:
Setpoint Relays:
Plastic, UL94 V0 or V1
Form C, 0.4A@125VAC, 2A@30VDC
Setability: 0.1%, with 1.0% hysteresis
Operating temperature: 0 to 60°C
Power: 115/230VAC, 50/60/400Hz, 4VA/channel
DC power available
Line Regulation:
BB101P, BB202P
±10%
Bar Segments: 101
Dimensions: 2.16"W x 6"H x 5.8"D
Panel Cutout: 1.77" x 5.7"
BW051P
BK051P
Orientation: Vertical or horizontal
Bar Segments: 51
Dimensions: 4.625" x 4.625" x 6.7"D
Panel Cutout: 4" dia ANSI switchboard
Bar Segments: 51
Dimensions: 3.82"W x 11.25"H x 7.10"D
Panel Cutout: 1.77" x 5.7"
▲
BW051P
▲
BK051P
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number
Order Example: BB101PVRYRHY1VAX-FS (0-150.0)
A B C D E F G H I J – K
–
L
–
M
A Basic Unit Basic Unit
BB BB101P CCBW BW051P
BC BB202P
(101 Segements each side)
CCBK BK051P
B Bargraph Orientation
H Horizontal (BP101P) V Vertical
C Bargraph Color
A Amber
G Green
D 4-Digit Display
X
A
None
Amber
R
S
G
R
Red (Standard)
Mixed
Green
(BW51/BK51 Only)
Red (Standard)
E Decimal Location
1
2
000.0
00.00
3
X
0.000
0000
F Setpoint Options (Must be ordered with Alarm Setpoint) (G)
X None A Amber
R Red G Green
G Alarm Setpoint (Must be ordered with Setpoint Option (F)
X
H
None
High/High
H Program Switches
L Low/Low
X None
I Primary Power
1
2
5
115 VAC
230 VAC
5 VDC
Y
4
6
8
Yes
24 VDC
12 VDC
48 VDC
J Signal Inputs
A
B
C
Amperes
Millivolts
T/C (Degrees C)
F T/C (Degrees F)
K Signal Type
A AC
L Special Options
D
X
M Scaling
None C
FS Factory Ranging (custom—specify scaling)
NOTE: Specify both sides for BB202P.
M Milliamperes
O Other
U Microamperes
V Volts
DC
Analog Retransmit
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Texmate
Intelligent Panel Meters
TIGER FAMILY
Intelligent Meter Controllers with Programmable Logic, Digital
Signal Processing Capabilities & Serial Communication
▲
DI-50E
1/8 DIN 96X48mm
▲
DI-60E
Tiger Family Features
• Intelligent and super-intelligent digital meters
• Front-panel digital calibration and function selection
• Built-in linearization function, 32 to 125 flexible points
• Built-in sensor excitation voltage 5 V /10 V / 24 V DC
• Six 5A relays or combinations of 10A relays and 5A relays
• Built-in memory for maximum and minimum readings
• Over 75 signal conditioners, single as well as dual inputs
• Two high-resolution, independently programmable 16-bit analog outputs
• Built-in timer and totalizer (signal integration) inputs, plus user-definable macros and real time clock
• Choice of serial communications – RS232, RS485, ASCII, Modbus and direct drive printer output
• Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC or
18-36 V AC / 9-60 V DC power supply
• Digital “smart” filtering
• Computer programmable
• Data logging up to 7000 samples
▲
GI-50E
9/32 DIN 144x72mm
▲
DI-60E
1/8 DIN 96X48mm
Leopard Family Features
LEOPARD FAMILY
Smart, Programmable Meter Relays with Isolated Retransmit or Control Loop Outputs
▲
DL-40
1/8 DIN 96X48mm
DL-40 LR
• Smart 4-digit meters
• Front-panel digital scaling, offset, and setpoints
• Over 38 different signal conditioners
• Dual 10 and 5-amp relays, 4 relays total plus analog output
• 1/16 DIN meters have 2 or 3 relays or 1 relay plus analog output
• Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC, or 18-36 V AC / 9-60 V DC power supply
Lynx Family Features
BL-40
1/16 DIN 96X24mm
• Basic indicator 3.5 or 4.5 digit, 0.56” and 0.8” LED meters
• Analog scaling and offset from rear
• Over 24 single-input signal conditioners available
• Auto-sensing AC / DC, wide range 85-265 V AC / 95-370 V DC, or 18-36 V AC / 9-60 V DC power supply
SPECIFICATIONS
LYNX FAMILY
1/8 DIN
96X48mm
1/16 DIN
96X24mm
Tiger Meter Specifications
Configured for Direct Connection to Most Sensors and Process
Signals, with Displays Scalable to Any Unit of Measure
▲
DX-35 LR
▲
DX-40 LR
▲
DX-35
▲
DX-45
Accuracy: Built-in compensation and linearization functions enable system accuracies of the order of ±0.0001% of reading for analog inputs. Stop -
Start time resolution from ±1sec to ±0.7nsec. Digital input and pulse counts
±1 count.
A/D Convertors: A Dual Slope, bipolar 17 bit A/D is provided as standard on the main board. SMART modules have 24 bit or 16 bit Delta-Sigma A/D convertors that utilize the internal I
2
C BUS.
Temperature Coefficient: Typically 30ppm/˚C. Compensation can be utilized to achieve system temperature coefficients of 1ppm.
Warm Up Time: Up to 10 minutes, depending on input module.
Conversion Rate: Typically 10 samples per second. However, SMART input modules are available that can convert at 60, 240, 480 or 960 samples per second.
Control Output Rate: Can be selected for 100msec or 10msec.
Some SMART modules have SSR outputs that react within 1.2msec.
Excitation Voltage: Depends on input module selected. Typically, 5V, 10V or 24VDC is provided.
Operating Temperature: 0 to 50 ˚C (32 ˚F to 122 ˚F).
Storage Temperature: -20 ˚C to 70 ˚C (-4 ˚F to 158 ˚F).
Relative Humidity: <95% (non-condensing) at 40 ˚C (104 ˚F).
Case Options: NEMA 4X Lens cover
▲
BX-35
▲
BX-45
Metal case surround
Panel Adapters
16
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
17
Texmate
Intelligent Panel Meters
Leopard Meter Specifications
A/D Converter:
Accuracy:
Temperature Coefficient:
Warm Up Time:
Conversion Rate:
Operating Temperature:
Storage Temperature:
Lynx Meter Specifications
A/D Converter:
Accuracy:
Temperature Coefficient:
Warm Up Time:
Conversion Rate:
Operating Temperature:
Storage Temperature:
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: DI-50E-DR-PS1-IA01-IAC-S2-R1
Basic Unit A – B – C – D – E – F – G
TIGER FAMILY METER SELECTION
A
B
C
D
E
F
G
DI-50E
DI-60AE
DI-60E
GI-50E
Intelligent Modular, 32 pt Linear, Analog out & relays
Intelligent Modular, Alpha Numeric 6 digit 0.56” LED
Intelligent Modular, Numeric 6 digit 0.56” LED
Intelligent Modular, w/ 5 digit 1” LED
Display
DR
DG
DB
Red LED
Green LED
Super-bright Red LED
Power Supply
PS1
PS2
85-265VAC/95-370VDC
18-36VAC/9-60VDC
Input Modules – See Input Module List "T" Items
Output Options
AIC
AIV
Isolated 4 to 20 mA Analog Output
Isolated 0 to 10 VDC Analog Output
Serial Communications
S2
S4
S5
Relays
Isolated RS-232 communication + ASCII
Isolated RS-485 communication + ASCII
Isolated ModBus Compatible + ASCII
R1
R2
R6
R13
R14
Single 5A Form A Relay
Two 5A Form A Relays
Six 5A Form A Relays
Two 10A Form C Relays, One 5A Form A Relay
Two 10A Form C Relays, Two 5A Form A Relays
LEOPARD FAMILY METER SELECTION
A
B
C
D
E
F
14 bit single slope
±(0.05% of reading + 2 counts)
100 ppm/°C (Typical)
2 minutes
5 conversions per second (Typical)
0 to 60°C, <95% (non condensing)
–20°C to 70°C
12 bit dual slope
±(0.05% of reading + 2 counts)
100 ppm/°C (Typical)
2 minutes
3 conversions per second (Typical)
0 to 60°C, <95% (non condensing)
–20°C to 70°C
BL-40
BL-40H
DL-40
DL-40H
Display
4.0 digit, Modular, Low Profile, Half Height Case
4.0 digit, Thermocouple & RTD, Half Height Case
4.0 digit, Modular, 1/8 DIN case
4.0 digit, Thermocouple & RTD, 1/8 DIN Case
DR
DG
DB
LG
LR
Power Supply
Red LED, 0.56 inch high
Green LED, 0.56 inch high
Super bright LED, 0.56 inch high
Large Green LED, 0.8 or 1 inch high
Large Red LED, 0.8 or 1 inch high
PS1
PS2
85-265VAC/95-370VDC
18-36VAC/9-60VDC
Input Modules – See Input Module List "L" Items
Output Options
AIC
AIV
Isolated 4 to 20 mA Analog Output
Isolated 0 to 10VDC Analog Output
Relays
R1
R2
R3
R4
Single 10A Form A Relay
Two 10A Form A Relay
Two 10A Form A Relays, One 5A Form A Relay
Two 10A Form A Relays, Two 5A Form A Relays
LYNX FAMILY METER SELECTION
A
B
C
D
E
BX-35
BX-45
DX-35
DX-40
DX-45
3.5 Digit Universal Power Supply, 1/16 DIN Case
4.5 Digit Universal Power Supply, 1/16 DIN Case
3.5 Digit Universal Power Supply, 1/16 DIN Case
4 Digit Universal Power Supply, 1/16 DIN Case
4.5 Digit Universal Power Supply, 1/16 DIN Case
Display
DR
DG
DB
LG
LR
Red LED
Green LED
Super-bright Red LED
Large Green LED, 0.8 inch high
Large Red LED, 0.8 inch high
Power Supply
PS1
PS2
85-265VAC/95-370VDC
18-36VAC/9-60VDC
Input Modules – See Input Module List "LY" Items
Output Options
AIC
AIV
Isolated 4 to 20 mA Analog Output
Isolated 0 to 10VDC Analog Output
INPUT MODULE SELECTION
Function Module For
AC
AC 1A, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA04 . . . . . . . T,L,Ly
AC 5A, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA05 . . . . . . . T,L,Ly
AC 1A, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA09 . . . . . . . T,L,Ly
AC 5A, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA11 . . . . . . . T,L,Ly
AC 2/20/200mA, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA03 . . . . . . . T,L,Ly
AC 2/20/200mA, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA08 . . . . . . . T,L,Ly
AC 100mV, Scaled RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA10 . . . . . . . T,L,Ly
AC 100mV, True RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA12 . . . . . . . T,L,Ly
AC 200/600V, Scaled RMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA01 . . . . . . . T,L,Ly
AC 200mV/2V/20V, Scaled RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA02 . . . . . . . T,L,Ly
AC 200/600V, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA06 . . . . . . . T,L,Ly
AC 200mV/2V/20V, True RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IA07 . . . . . . . T,L,Ly
DC
DC 5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID04. . . . . . . T,L,Ly
DC 1A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID09. . . . . . . T,L,Ly
DC 2/20/200mA w/ 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ID03. . . . . . . T,L,Ly
DC 2/20/200mA w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . ID07. . . . . . . T,L,Ly
DC 20/50/100/200mV w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . ID02. . . . . . . T,L,Ly
DC 2/20/200V/Custom w/ 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . . . ID01. . . . . . . T,L,Ly
DC 2/20/200V/Custom w/ Ext. Decimal Select . . . . . . . . . . . . . . . . ID06 . . . . . . . . T
DC 2/20/200V/Custom w/ External LIN Table Select . . . . . . . . . . . ID08 . . . . . . . . T
DC 2/20/200V/Custom w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . ID05. . . . . . . T,L,Ly
DC Watts, 200V & 50mV from shunt . . . . . . . . . . . . . . . . . . . . . . . . . IW03 . . . . . . . . T
DC 2V and 3-wire RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT3. . . . . . . . . T
Dual DC 2mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD3 . . . . . . . . T
Dual DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD2 . . . . . . . . T
Dual DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD1 . . . . . . . . T
DC 50mV and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD6 . . . . . . . . T
DC 2V and 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD5 . . . . . . . . T
DC 2V and 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD4 . . . . . . . . T
DC 50mV and J K R S T B N Thermocouple . . . . . . . . . . . . . . . . . . . . . IDT5. . . . . . . . . T
DC 2V and J K R S T B N Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . IDT4. . . . . . . . . T
DC 1-5V Process w/ Offset & 24V Exc. . . . . . . . . . . . . . . . . . . . . . . . IP03 . . . . . . . T,L,Ly
DC 2/5/10/20V/2/20mA + 3 Digital Inputs. . . . . . . . . . . . . . . . . . . IP10. . . . . . . . . T
Triple DC 50mV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD2. . . . . . . . . T
Triple DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD1. . . . . . . . . T
DC 50mV and 50mV and J K R S T B N T/C. . . . . . . . . . . . . . . . . . . . . ITT6 . . . . . . . . . T
DC 50mV and 2V and J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . ITT9 . . . . . . . . . T
DC 2V and 2V and J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . ITT7 . . . . . . . . . T
DC 50mV and two J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . ITT5 . . . . . . . . . T
DC 2V and two J K R S T B N T/C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITT3 . . . . . . . . . T
DC Volts and T/C and Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITTG . . . . . . . . . T
Quad DC 50mV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD2 . . . . . . . . T
Quad DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD1 . . . . . . . . T
RTD + DC V + DC V + Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQT5. . . . . . . . . T
Smart DC V, 16 bit, 1 to 800 Hz update rates . . . . . . . . . . . . . . . . . ISD1* . . . . . . . T
Smart DC V, 16 bit, 1 to 960 Hz update rates . . . . . . . . . . . . . . . . . ISD2** . . . . . . T
Smart DC V, 16 bit, 1 to 800 Hz w/dual SSRs . . . . . . . . . . . . . . . . . ISD3* . . . . . . . T
Smart DC V, 16 bit, 1 to 960 Hz w/dual SSRs . . . . . . . . . . . . . . . . . ISD4** . . . . . . T
Smart DC V, High Res & Acc, 24 bit 1-400Hz . . . . . . . . . . . . . . . . . . ISD5* . . . . . . . T
Smart DC V, High Res & Acc, 24 bit 1-480Hz . . . . . . . . . . . . . . . . . . ISD6** . . . . . . T
Smart DC V, High Res & Acc, 1-400Hz w/dual SSRs . . . . . . . . . . . . ISD7* . . . . . . . T
Smart DC V, High Res & Acc, 1-400Hz w/dual SSRs . . . . . . . . . . . . ISD8** . . . . . . T
Smart Dual 3-wire Potentiometer (50 Hz) . . . . . . . . . . . . . . . . . . . . . ISR3* . . . . . . . T
Smart Dual 3-wire Potentiometer (60 Hz) . . . . . . . . . . . . . . . . . . . . . ISR4** . . . . . . T
Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . . . . . . . . . . . . . . . . ISDA* . . . . . . . T
Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . . . . . . . . . . . . . . . . ISDB** . . . . . . T
Smart Load Cell and RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISSB. . . . . . . . . T
DC Process 2/5/10/20/200V/2/20mA w/ 24V Exc.. . . . . . . . . . . . IP07 . . . . . . . . T,L
DC Process 2/5/10/20/200V/2/20mA w/ 24V Exc & AutoCal . . . IP08. . . . . . . . . T
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Texmate
Intelligent Panel Meters
INPUT MODULE SELECTION - CONTINUED
Function Module For
COUNTER
Quadrature Counter . . . . . . . . . . . . . . . . . . . . . . . . IC02 . . . T
Quadrature Counter w/dual SSRs. . . . . . . . . . . . . IC03 . . . T
Universal Freq./ RPM / Up Down Counter . . . . . . IF10 . . . T
Dual UP/DOWN Counter. . . . . . . . . . . . . . . . . . . . . IDC1 . . . T
Counter and T/C and 4-20mA . . . . . . . . . . . . . . . . ITTF . . . T
Smart Dual Counter and Pressure Direct . . . . . . . ISP1 . . . T
DUAL INPUTS
3-wire RTD and DC V . . . . . . . . . . . . . . . . . . . . . . . IDT3 . . . T
3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T
Dual DC 2mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD3. . . T
Dual DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD2. . . T
DC 50mV and 4-20mA . . . . . . . . . . . . . . . . . . . . . . IDD6. . . T
DC 2V and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . IDD5. . . T
DC 2V and DC 50mV . . . . . . . . . . . . . . . . . . . . . . . IDD4. . . T
Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T
Dual DC 2V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDD1. . . T
Dual Direct Pressure (Abs. or Differential/Gage). . . IGYY . . . T
Dual Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDF2 . . . T
Dual Pressure Input . . . . . . . . . . . . . . . . . . . . . . . . IDS2 . . . T
Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T
Dual Resistance Input . . . . . . . . . . . . . . . . . . . . . . IDR1. . . T
Dual RTD Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT2 . . . T
Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS5* . . T
Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS6** . T
Dual Strain Gage Input. . . . . . . . . . . . . . . . . . . . . . IDS1 . . . T
Dual Thermocouple . . . . . . . . . . . . . . . . . . . . . . . . IDT1 . . . T
Thermocouple and 4-20mA . . . . . . . . . . . . . . . . . . IDP3 . . . T
Thermocouple and DC mV . . . . . . . . . . . . . . . . . . . IDT5 . . . T
Thermocouple and DC V . . . . . . . . . . . . . . . . . . . . IDT4 . . . T
Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T
Dual UP/DOWN Counter. . . . . . . . . . . . . . . . . . . . . IDC1 . . . T
Smart Dual 3-wire Potentiometer . . . . . . . . . . . . . ISR3 . . . T
Smart Load Cell and Process (4-20mA) . . . . . . . . . ISS9 . . . T
Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . ISDA* . . T
Smart Dual DC Volts, 16 bit, 1-20Hz update . . . . ISD8**. T
Smart Dual Photo Diode Input. . . . . . . . . . . . . . . . ISSE . . . T
Smart Dual RTD (50Hz) . . . . . . . . . . . . . . . . . . . . . IST5* . . T
Smart Dual RTD (60Hz) . . . . . . . . . . . . . . . . . . . . . IST6** . T
4 - 20mA
3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T
DC 50mV and 4-20mA . . . . . . . . . . . . . . . . . . . . . . IDD6. . . T
DC 2V and 4-20mA. . . . . . . . . . . . . . . . . . . . . . . . . IDD5. . . T
Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T
Thermocouple and 4-20mA . . . . . . . . . . . . . . . . . . IDP3 . . . T
Process Loop 4-20mA . . . . . . . . . . . . . . . . . . . . . . IP01 . T,L,Ly
Process Loop 4-20mA w/ Ext. Lin Table . . . . . . . IP09 . T,L,Ly
Process Loop 4-20mA w/ 24V Exc. & AutoCal . . IP06 . . . T
Process Loop 4-20mA w/ 24V Exc. . . . . . . . . . . . IP02 . T,L,Ly
Quad 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQP1 . . . T
Smart Load Cell and Process 4-20mA . . . . . . . . . . ISS9 . . . T
Triple 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITP1 . . . T
4-20mA and 4-20mA and T/C . . . . . . . . . . . . . . . . ITT8 . . . T
T/C and 4-20mA and Counter . . . . . . . . . . . . . . . . ITTF . . . T
T/C and 4-20mA and DC mV . . . . . . . . . . . . . . . . . ITTA . . . T
T/C and 4-20mA and DC Volts . . . . . . . . . . . . . . . ITTB . . . T
T/C and 4-20mA and Frequency . . . . . . . . . . . . . . ITTF . . . T
T/C and T/C and 4-20mA . . . . . . . . . . . . . . . . . . . ITT4 . . . T
FREQUENCY / RPM
Universal Freq./ RPM / Up Down Counter . . . . . . IF10 . . . T
Universal Frequency / RPM . . . . . . . . . . . . . . . . . . IF05 . . . L
Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF08 . . . L
Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF06 . . . T
Dual Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDF2 . . . T
Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T
RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T
T/C and 4-20mA and Frequency . . . . . . . . . . . . . . ITTF . . . T
T/C and DC Volts and Frequency. . . . . . . . . . . . . . ITTG . . . T
RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T
LVDT
Smart Dual LVDT (50 Hz) . . . . . . . . . . . . . . . . . . . . ISL1* . . T
Smart Dual LVDT (60 Hz) . . . . . . . . . . . . . . . . . . . . ISL2** . T
OXIDATION REDUCTION POTENTIAL
Oxidation Reduction Potential (ORP). . . . . . . . . . . IOR1. . . T pH pH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IH01 . . . T pH w/ Automatic Temperature Compensation . . . IH02 . . . T
Function Module For
POTENTIOMETER
3-wire Potentiometer 1kΩ min. . . . . . . . . . . . . . . . IR02 . T,L,Ly
Linear Potentiometer 1kΩ min . . . . . . . . . . . . . . . IR03 . . T,L
Smart Dual 3-wire Potentiometer (50 Hz). . . . . . . ISR3* . . T
Smart Dual 3-wire Potentiometer (60 Hz). . . . . . . ISR4**. T
Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T
Smart Single 3-wire Potentiometer (50 Hz) . . . . . ISR1* . . T
Smart Single 3-wire Potentiometer (60 Hz) . . . . . ISR2**. T
PRESSURE / LOAD CELL
Universal Direct Pressure . . . . . . . . . . . . . . . . . . . . IGYZ . T,L,Ly
Direct Pressure with 2 Digital Inputs . . . . . . . . . . IGYX . . . T
Dual Direct Pressure (Abs. or Differential/Gage) . IGYY . . . T
Dual Pressure Input . . . . . . . . . . . . . . . . . . . . . . . . IDS2 . . . T
Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS5* . . T
Dual Smart Pressure/Load Cell, 16 bit. . . . . . . . . ISS6** . T
Pressure/Load Cell 20/2mV/V, 5/10V
Exc, 4-wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IS05 . T,L,Ly
Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire. . IS06 . T,L,Ly
Pressure/Load Cell Ext Exc., High Impedance . . . IS07 . . T,L
Pressure/Load Cell Ext Exc., 4/6-wire. . . . . . . . . . IS04 . . T,L
Pressure/Load Cell w/ AutoCal, 4-wire . . . . . . . . . IS03 . . . T
Pressure/Load Cell, 4/6-wire. . . . . . . . . . . . . . . . . IS02 . . T,L
Smart Pressure/Load Cell, Standard Res 16 bit . ISS1* . . T
Smart Pressure/Load Cell, Standard Res 16 bit . ISS2** . T
Smart Pressure/Load Cell, High Res & Acc 24 bit . ISS3* . . T
Smart Pressure/Load Cell, High Res & Acc 24 bit . ISS4** . T
Smart Quad Pressure/Load Cell (50 Hz) . . . . . . . ISS7* . . T
Smart Quad Pressure/Load Cell (60 Hz) . . . . . . . ISS8** . T
Smart Pressure Direct & Dual Counter. . . . . . . . . . ISP1 . . . T
Smart Load Cell and Process 4-20mA . . . . . . . . . . ISS9 . . . T
Smart Load Cell and RTD. . . . . . . . . . . . . . . . . . . . ISSB . . . T
Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSC* . . T
Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSD**. T
Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T
PROCESS LOOP
Dual Process Loop . . . . . . . . . . . . . . . . . . . . . . . . . IDP1 . . . T
Process Loop 4-20mA . . . . . . . . . . . . . . . . . . . . . . IP01 . T,L,Ly
Process Loop 4-20mA w/ Ext. Lin Table . . . . . . . . . . IP09 . . . T
Process Loop 4-20mA w/ 24V Exc. & AutoCal. . . . . . IP06 . . . T
Process Loop 4-20mA w/ 24V DC Exc. . . . . . . . . IP02 . T,L,Ly
QUAD INPUTS
Quad 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQP1 . . . T
Quad DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD2. . . T
Quad DC 2V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQD1. . . T
Quad RTD Platinum 2 wire connection. . . . . . . . . IQT2 . . . T
Quad RTD Platinum 4 wire connection. . . . . . . . . IQT4 . . . T
RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T
Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T
Smart Quad Pressure/Load Cell (50 Hz) . . . . . . . ISS7* . . T
Smart Quad Pressure/Load Cell (60 Hz) . . . . . . . ISS8** . T
Smart Quad Thermocouple (50 Hz) . . . . . . . . . . . IST3* . . T
Smart Quad Thermocouple (60 Hz) . . . . . . . . . . . IST4** . T
RESISTANCE
Dual Resistance 0.2/2/20kΩ . . . . . . . . . . . . . . . . IDR1. . . T
Resistance 200/2k/20kΩ, 2/3/4-Wire . . . . . . . . IR01 . . . T
Resistance 2kΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . IR04 . . . L
Resistance 2kΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . IR05 . . Ly
Smart Quad Potentiometer/Resistance . . . . . . . . ISSA . . . T
Smart Voltage and Resistance . . . . . . . . . . . . . . . ISD9 . . . T
RTD
3-wire RTD and DC V . . . . . . . . . . . . . . . . . . . . . . . IDT3 . . . T
3-wire RTD and 4-20mA . . . . . . . . . . . . . . . . . . . . . IDP2 . . . T
Dual RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IDT2 . . . T
Quad RTD Platinum 2 wire. . . . . . . . . . . . . . . . . . . IQT2 . . . T
Quad RTD Platinum 4 wire. . . . . . . . . . . . . . . . . . . IQT4 . . . T
RTD + DC V + DC V + Frequency . . . . . . . . . . . . . . IQT5 . . . T
RTD, 10Ω Copper 2/3/4-wire . . . . . . . . . . . . . . . . IT13 . . . T
RTD, 100Ω Pt. 2/3/4-wire . . . . . . . . . . . . . . . . . . . IT02 . . . T
RTD, 100Ω Pt. 2/3/4-wire (-199.9 to 199.9˚C). . IT14 . T,L,Ly
RTD, 100Ω Pt. 2/3/4-wire (-199.9 to 199.9°F). . IT05 . T,L,Ly
RTD, 100Ω Pt. 2/3/4-wire (-200 to 800°C) . . . . . IT03 . T,L,Ly
RTD, 100Ω Pt. 2/3/4-wire (-200 to 1470°F) . . . . IT04 . T,L,Ly
RTD, 100Ω Pt. 3/4-wire, °C/°F, 1°/0.1°. . . . . . . IT11 . . . L
RTD, 120Ω Nickel 2/3/4-wire . . . . . . . . . . . . . . . . IT12 . . . T
RTD, 1000Ω Pt. Select 3/4-wire, °C/°F, 1°/0.1° . IT15 . . . L
Smart Load Cell and RTD. . . . . . . . . . . . . . . . . . . . ISSB . . . T
Smart Dual RTD (50Hz) . . . . . . . . . . . . . . . . . . . . . IST5* . . T
Smart Dual RTD (60Hz) . . . . . . . . . . . . . . . . . . . . . IST6** . T
Smart 6 Input - 3 RTD, 2 Process, 1 Digital . . . . . IST1* . . T
Smart 6 Input - 3 RTD, 2 Process, 1 Digital . . . . . IST2** . T
Triple RTD Platinum 100Ω, 4-wire . . . . . . . . . . . . . ITTC . . . T
Function Module For
Triple RTD Platinum 100Ω, 2-wire . . . . . . . . . . . . . ITT2 . . . T
RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T
SINGLE PHASE POWER
Single Phase Power, 300V/1A. . . . . . . . . . . . . . . . IW01 . . T
Single Phase Power, 300V/5A. . . . . . . . . . . . . . . . IW02 . . T
Single Phase Power, 600V/1A. . . . . . . . . . . . . . . . IW04 . . T
Single Phase Power, 600V/5A. . . . . . . . . . . . . . . . IW05 . . T
STRAIN GAGE
Strain Gage and Frequency . . . . . . . . . . . . . . . . . . IDS3 . . . T
Dual Strain Gage. . . . . . . . . . . . . . . . . . . . . . . . . . . IDS1 . . . T
Strain Gage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IS01 . . T,L
THERMOCOUPLE
Dual Thermocouple J K R S T B N . . . . . . . . . . . . . . IDT1 . . . T
T/C J K R S T B N and 4-20mA. . . . . . . . . . . . . . . . . IDP3 . . . T
T/C J K R S T B N and DC 50mV . . . . . . . . . . . . . . . IDT5 . . . T
T/C J K R S T B N and DC 2V . . . . . . . . . . . . . . . . . . IDT4 . . . T
Thermocouple and Load Cell. . . . . . . . . . . . . . . . . IDT6 . . . T
Smart Quad Thermocouple (50 Hz) . . . . . . . . . . . IST3* . . T
Smart Quad Thermocouple (60 Hz) . . . . . . . . . . . IST4** . T
Thermocouple J K R S T B N . . . . . . . . . . . . . . . . . . . IT01 . . . T
T/C, J K R T, Selectable°C/°F, 1°/0.1° . . . . . . . . IT10 . . . L
T/C J K R S T B N , 4-20mA and 4-20mA . . . . . . . . . ITT8 . . . T
T/C J K R S T B N , 4-20mA and Counter. . . . . . . . . . ITTF . . . T
T/C J K R S T B N , 4-20mA and DC 50mV. . . . . . . . ITTA . . . T
T/C J K R S T B N , 4-20mA and DC 2V. . . . . . . . . . . ITTB . . . T
T/C J K R S T B N , DC 50mV and DC 50mV . . . . . . ITT6 . . . T
T/C J K R S T B N , DC 2V and DC 50mV . . . . . . . . . ITT9 . . . T
T/C J K R S T B N , DC 2V and DC 2V . . . . . . . . . . . . ITT7 . . . T
T/C J K R S T B N , T/C and 4-20mA . . . . . . . . . . . . . ITT4 . . . T
T/C J K R S T B N , T/C and DC 50mV . . . . . . . . . . . ITT5 . . . T
T/C J K R S T B N , T/C and DC 2V . . . . . . . . . . . . . . ITT3 . . . T
T/C, 4-20mA and Frequency . . . . . . . . . . . . . . . . . ITTF . . . T
T/C, DC Volts and Frequency . . . . . . . . . . . . . . . . . ITTG . . . T
Triple Thermocouple J K R S T B N . . . . . . . . . . . . . ITT1 . . . T
TRIPLE INPUTS
Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSC* . . T
Smart Load Cell and Two Digital Inputs . . . . . . . . . ISSD**. T
Smart Pressure Direct & Dual Counter . . . . . . . . . . ISP1 . . . T
Triple 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITP1 . . . T
Triple DC 50mV . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD2 . . . T
Triple DC 2V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ITD1 . . . T
Triple RTD Platinum 100Ω, 4-wire . . . . . . . . . . . . . ITTC . . . T
Triple RTD Platinum 100Ω, 2-wire . . . . . . . . . . . . . ITT2 . . . T
RTD and RTD and Frequency. . . . . . . . . . . . . . . . . ITTE . . . T
T/C J K R S T B N , 4-20mA and 4-20mA . . . . . . . . . ITT8 . . . T
T/C J K R S T B N , 4-20mA and Counter. . . . . . . . . . ITTF . . . T
T/C J K R S T B N , 4-20mA and DC 50mV. . . . . . . . ITTA . . . T
T/C J K R S T B N , 4-20mA and DC 2V. . . . . . . . . . . ITTB . . . T
T/C J K R S T B N , DC 50mV and DC 50mV . . . . . . ITT6 . . . T
T/C J K R S T B N , DC 2V and DC 50mV . . . . . . . . . ITT9 . . . T
T/C J K R S T B N , DC 2V and DC 2V . . . . . . . . . . . . ITT7 . . . T
T/C J K R S T B N , T/C and 4-20mA . . . . . . . . . . . . . ITT4 . . . T
T/C J K R S T B N , T/C and DC 50mV . . . . . . . . . . . ITT5 . . . T
T/C J K R S T B N , T/C and DC 2V . . . . . . . . . . . . . . ITT3 . . . T
T/C, 4-20mA and Frequency . . . . . . . . . . . . . . . . . ITTF . . . T
T/C, Volts and Frequency . . . . . . . . . . . . . . . . . . . . ITTG . . . T
Triple Thermocouple J K R S T B N . . . . . . . . . . . . . ITT1 . . . T
*Optimized for 50 Hz rejection. **Optimized for 60 Hz rejection.
ENHANCED TIGER FAMILY MODELS
DI-503
Triple Display
Meters
▲
DI-602A
Dual Display Meters
Digital
Meter with
Annunciators
DI-50/AN6
▲
DI-802X
Dual Line Alphanumeric LCD
18
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
19
WESCHLER INSTRUMENTS
Texmate
Application-Specific Meters and Controllers
DU-SERIES 1/8 DIN (96 x 48mm) METERS
Standard user selectable 100/120 VAC or 200/240 VAC power supply, option 24 VAC, or auto sensing isolated AC/DC 9 to 24 VAC,
12 to 36 VDC. 0.56" std. red or optional green or super bright red
LED display.
AC Current
DU-35ACI
........
AC Amperes, Average, 1A and 5A (built-in shunt)
DU-35ACIRMSAC Amperes, True RMS 1A and 5A (built-in shunt)
DU-40ACI
........
4-Digit Version of the DU-35ACI
AC Voltage
DU-35AC
........
AC Volts, Average, 199.9/700.0 VAC
DU-35ACRMSAC Volts, True RMS 199.9V/700V
DU-40AC
........
AC Volts, Average, 700.0 VAC, 4-Digit
AC Line Frequency
DU-35HZ
..........
Line Frequency 199.9 or 500 Hz up to 700V AC input w/3.5-Digit
DC Voltage
DU-35
............
DC Volts Selectable from 2V/20V/200V, 3.5-Digit
DU-35MV
........
DC mV Selectable 50 mV/100 mV/200 mV, 3.5-Digit
DU-45
............
DC Volts Selectable from 2 V/20V/200V, 4.5-Digit
DU-45MV
........
DC mV Selectable 50 mV/100 mV/200 mV 4.5-Digit
Process 4 to 20 mA
DU-35CL
DU-35CLE
DU-45CL
........
Process 4 to 20 mA, 3.5-Digit
........
Process 4 to 20 mA with 24 VDC Excitation, 3.5-Digit
........
Process 4 to 20 mA, 4.5-Digit
Pressure
DU-35P
............
Strain Gauge, Load Cell, and Pressure, 4- and 6-Wire,
5 VDC Excitation, Selectable Sensitivity from 2 mV to 20 mV/V, 3.5-Digit, 0.56" LED Display
Temperature
DU-35J
DU-35K
..........
Thermocouple J or K, °C or °F, 3.5-Digit, 0.56" LED
..........
Thermocouple J or K, °C or °F, 3.5-Digit, 0.56" LED
DU-35RTD
......
100Ω Platinum RTD, 2-, 3-, or 4-Wire, °C or °F, 3.5-Digit
Metal Case Option for 96 x 48mm DIN Case
OP-MTL96X48 Provides Extra Strength and Protection Against Fire
OP-MTLCLIP Mounting clips
SD-SERIES 1/8 DIN (96 x 48 mm) ULTRA SHORT-DEPTH
Only 1.2" depth behind panel, including connectors.
DC Voltage
SD-35
............
3.5-Digit, 0.56" standard red LEDs (optional green or super bright red). 2/20/200/Custom DCV ranges, 5VDC power.
Pin compatible with Asahi AP-501.
4-20mA Loop Powered
SD-50X
..........
5-Digit 0.5" LCD. 3.5-27.5mA input span, -19999 to 30000 count display. 6th digit displays F, C, inactive 0 or blank.
AM-SERIES 1/16 DIN (96 x 24 mm) SHORT-DEPTH BARGRAPHS
5 VDC power supply. 30 segment standard red or optional green or amber LED display.
Selectable Process 4 to 20 mA or DC Voltage
AM-30
............
6 Header Selectable DC Ranges Plus 4 to 20 mA
AM-30R1
AM-30R2
........
6 DC + 4 to 20 mA w/One 2A/120 VAC Relay
........
6 DC + 4 to 20 mA w/Two 2A/120 VAC Relays
BN-SERIES 1/16 DIN (96 x 24 mm) SHORT-DEPTH METERS
Standard 24 VDC isolated power supply, option 12V or 15 V. 0.56" std. red or optn. green or super bright red LED display.
Process 4 to 20 mA
BN-35CL
........
Process 4 to 20 mA, 3.5-Digit
DC Voltage
BN-35I
..........
DC Volts Selectable from 2V/20V/200V, 3.5-Digit
BN-45I
..........
DC Volts Selectable from 2V/20V/200V, 4.5-Digit
Meters below, 5 VDC power supply. 0.56" standard red or optional green or super bright red LED display.
BN-35
BN-45
............
DC Volts Selectable from 2V/20V/200V, 3.5-Digit
............
DC Volts Selectable from 2V/20V/200V, 4.5-Digit
BCD Remote Display
BN-35BCD
BN-40BCD
......
Remote BCD Display 3.5-Digit
......
Remote BCD Display 4-Digit
Meter below, AC/DC auto sensing isolated power supply
85 to 256 VAC/90 to 380 VDC power supply. 0.3" standard red or optional green or super bright red LED display.
Dual AC Volts and Hertz, Signal Powered
DD-40VHZ
........
3.5-Digit, 0.3" LED Display
MU-SERIES 1/32 DIN (48 x 24 mm) METERS
AC/DC auto sensing isolated power supply 12 to 24 VAC/9 to
36 VDC power supply. 0.3" standard red or optional green or super bright red LED display.
MU-35
............
DC Volts Selectable from 2V/20V/200V
MU-35MV
..........
DC mV Selectable from 50 mV/100 mV/200 mV
MU-35CL
..........
Process 4 to 20 mA
UM-SERIES—NEMA CASE LOW-COST UTILITY METERS
Optional 0.8" display
Standard user selectable 100/120 VAC or 200/240V AC power supply, optn. 24 VAC, or auto sensing isolated AC/DC 9 to 24 VAC, 12 to 36 VDC.
0.56" std. red or optn. 0.8" std. red (3.5-digit and UM-40AC only) or green or super bright red LED display.
AC Current
UM-35ACI
........
AC Amps, Average, 1A or 5A, 3.5-Digit Display
AC Voltage
UM-35AC
UM-40AC
........
700 VAC and 199.9 VAC Full Scale, 3.5-Digit Display
........
700.0 VAC FS, 0.1V Resolution, 4-Digit Display
AC Line Frequency
UM-35HZ
........
40 Hz to 199.9 Hz or 40 Hz to 500 Hz, 3.5-Digit
DC Voltage
UM-35
............
±2/20 VDC or Optionally ±2/200 VDC, 3.5-Digit
UM-35MV
........
±50 mV and ±00 mV Inputs to Suit External DC
Current Shunts, 3.5-Digit
UM-45
............
±2/20 VDC or Optionally ±2/200 VDC, 4.5-Digit
UM-45MV
........
±50 mV, ±100 mV, or ±200 mV Inputs to Suit
Standard DC Current Shunts, 4.5-Digit
Process 4 to 20 mA
UM-35CL
........
1.4V Loop Drop, Scalable in Engineering Units from
-1999 to +1999, 3.5-Digit
UM-35CLE
UM-45CL
......
Built-In 24 VDC Loop Excitation
........
4.5-Digit Version of UM-35CL as Above
Pressure
UM-35P
..........
For Pressure Transducers with 2 mV/V to 20 mV/V
Outputs with 5 VDC Exc., 3.5-Digit
Thermocouple, 3.5-Digit
UM-35J
UM-35K
..........
Designed for J Thermocouple Input, 1° Resolution
..........
Designed for K Thermocouple Input, 1° Resolution
UM-35RTD
......
3-Wire, 100-Ohm RTD, 0.1° or 1° Resolution
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Texmate
Application-Specific Meters and Controllers
MINI-METER DVM-5 SERIES, 1.378 x 0.5 x 1.375" CASE
Loop-Powered, Process 4 to 20 mA
DVM-5/CL
............
3.5-Digits, 0.276" LED Display
Volt and RTD, 5 VDC Power
DVM-5
................
200 mV to 200 VDC, 0.276" LED Display
DVM-5/RTD
..........
RTD Sensor Input, 0.276" LED Display
SM SERIES 3-WIRE DC INPUT
20 mV to 2 VDC, 3.5-Digit LED/LCD, 5 VDC Power
SM-35
............
2 to 20 VDC, 0.56" LED, Display Hold
SM-35X
............
2 to 20 VDC, 0.48" LCD, Display Hold
SM-35MV
..........
20 mV to 2 VDC LED Constant Current 5 VDC
Power Supply Eliminates Ground Loop Problems
SM-35XMV
........
20 mV to 2 VDC LCD Constant Current 5 VDC
Power Supply Eliminates Ground Loop Problems
LOOP POWERED LED BARGRAPH
1/16 DIN 96x24mm, 31 segment red or green LEDs. Only 4V loop drop,
3" behind panel.
SB-B31 ..................4-20mA Loop Powered Bargraph
SLIM-BEZEL CASE LED AND LCD MINIATURE METERS
Loop-Powered, Process 4 to 20 mA, 0.48" LCD
CM-35XTL
............
Less than 1 VDC Loop Drop and 1 Joule Energy
CM-35XT
Storage. Fully Scalable
............
Economical Standard 6.5V Loop Drop
DC and AC 2-Wire Signal-Powered, 0.48" LCD
SP-35X
..............
±3.5 VDC to 199.9 VDC
SP-35XRMS
SP-35XMV
........
AC or DC 15.0V to 199.9V and 15.0V to 250V
..........
50 mV shunt/10 to 100 VDC Power
Low Cost DC Bargraph, 5 VDC Power
AM-20
..............
20 Segment, 200 mV to 200 VDC, 5 VDC Power
DC Volts, 4.5 Digit LED/LCD, 5 VDC Power
PM-45X/45XU
PM-45L
........
200 mV to 1200V BCD Output Option
..............
200 mV to 1200 VDC and BCD Output Option
CP-45
................
BCD Comparator Form C Relay 5 VDC Power
J and K Thermocouple Meters LED/LCD
TM-35J
TM-35K
TM-35XJ
..............
Differential Input Configuration Allows Several
................
Meters to be Operated with Grounded Thermocouples
................
from the Same 5 VDC Power Supply. Select °C or °F.
TM-35XK
RP AND PM SERIES METERS
DC Input, 110/230 VAC Power
RP-35U
............
Economy DC inputs, 3.5-Digit, 0.56" LED Display
RP-35A
............
Precision Differential DC Input, 3.5-Digit, 0.56" LED
RP-35AR
..........
Auto Dual Ranging, 3.5-Digit, 0.56" LED Display
RP-3500
..........
Single Ended Input 3.5-Digit, 0.56" LED Display
RP-3500D2
......
3.5-Digit Differential Input with Optional BCD
RP-4500
..........
Single Ended Input 4.5-Digit, 0.56" LED Display
RP-4500D2
......
4.5-Digit Differential Input with Optional BCD
DC Input, 5 VDC Power
PM-35U
PM-35A
PM-35AR
PM-35X
..........
Low Cost, 3.5-Digit, 0.3" LED Display
..........
Differential Inputs, 3.5-Digit, 0.56" LED Display
..........
Auto Range, 3.5-Digit, 0.56" LED Display
..........
Low Power, 3.5-Digit, 0.48" LCD Display
PM-35XAC110
..........
DC Input 110/220 VAC Power, 0.48" LCD Display
PM-45
............
Single Ended 4.5-Digit, 0.3" LED Display
Basic Unit
AM-20
AM-30
AM-30R1
AM-30R2
BN-35
BN-35BCD
BN-35CL
BN-35I
BN-40BCD
BN-45
BN-45I
CM-35XT
CM-35XTL
CN-PUSH/XX
CP-45
DD-40VHZ
DU-35
DU-35AC
$ 85
$ 119
DU-35ACI1 $ 125
DU-35ACI1RMS $ 145
DU-35ACI5 $ 125
DU-35ACI5RMS $ 145
DU-35ACRMS
DU-35CL
$ 139
$ 105
$ 119
$ 129
$ 119
$ 119
$ 99
$ 159
$ 55
$ 109
$ 139
$ 169
$ 99
$ 149
$ 139
$ 129
$ 169
$ 119
$ 149
$ 86
$ 110
$ 18
$ 95
$ 160
DU-35CLE
DU-35HZ
DU-35J
DU-35K
DU-35MV
DU-35P
DU-35RTD
DU-40AC
$ 119
$ 159
DU-40ACI1 or 5 $ 169
DU-45 $ 149
$ 159
$ 155
$ 79
DU-45CL
DU-45MV
DVM-5
DVM-5/4-20
DVM-5/CL
DVM-5/G
DVM-5/MV
DVM-5/RTD
MU-35
MU-35MV
MU-35CL
OP-MTL96X48
OP-MTLCLIP
$ 99
$ 109
$ 84
$ 79
$ 109
$ 99
$ 109
$ 119
$ 10
$ 6
OP-N4X/96X48 $ 20
PM-35A
PM-35AR
PM-35U
PM-35X
PM-35XAC
PM-45
RP-35A
RP-35AR
RP-35U
RP-3500
$ 65
$ 92
$ 39
$ 79
$ 94
$ 85
$ 79
$ 110
$ 69
$ 105
ORDERING INFORMATION
Basic Unit
RP-3500D2
RP-4500
RP-4500D2
SB-B31
SD-35
SD-50X
SM-35
SM-35MV
SM-35X
SM-35XMV
SP-35X
SP-35XRMS
SP-35XMV
TM-35J
TM-35K
TM-35XJ
TM-35XK
UM-35
UM-35AC
UM-35ACI1 or 5
UM-35CL
UM-35CLE
UM-35HZ
UM-35J
UM-35K
UM-35MV
UM-35P
UM-35RTD
UM-40AC
UM-45
UM-45CL
UM-45MV
OPTIONS
Display Options
BRIGHT
GREEN
LARGE/GREEN
LARGE/RED
Power Supply
V0-24V
V0-50K
V0-DC/ISO
Input Range
CB-FS35
CB-FS45
HD-CHANGE
Connectors
CN-L10
CN-L15
CN-PUSH/BN
Special Options
OP-MTL96X48
OP-N4SEAL/UM
OP-N4X/96X48
SCREW TERMINAL OPTIONS
FOR UM AND SM SERIES
AC ADAPTERS (120V)
PS-2405 Regulated
PS-520 Regulated
$ 135
$ 125
$ 165
TB-KIT
..........
Individual Screw Terminal
Blocks are Included with all
UM and SM Meter Orders
CN-PUSH/XX ....Ten Position Screw Terminal
Assemblies, Pre-configured for Texmate Meters w/Gold
Fingered PCB Inputs
$ 89
$ 99
$ 95
$ 95
$ 75
$ 139
$ 95
$ 109
$ 129
$ 144
$ 135
$ 59
$ 49
$ 69
$ 59
$ 79
$ 89
$ 105
$ 99
$ 94
$ 94
$ 104
$ 104
$ 64
$ 79
$ 85
$ 72
20
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Newport
Panel Meters/Controllers
INFCAC Series
• 4-Digit, 14-Segment LED Display, Red or Green
• High ±0.1% of Reading Accuracy
• Wide Selection of AC Current and Voltage Ranges
• Smart Filtering Detects the Difference Between a Spike or Process Change (Patent Pending)
• Front Panel Configuration
• Available with Dual 6 Amp Relays and/or Analog Output
INFCAC
INFC Series
• Process (DC Voltage and Current), Strain Gauge,
Thermocouple, and RTD
• Dual Differential Thermocouple and RTD
• pH ORP
• Relay Output Optional
• Isolated or Non-Isolated Analog Output Optional
IDP-0
IDP Series
• Easy Scaling
• 4-Digit LED Display
• Max or Min Recall
• Short Case 4.1" (104 mm)
• Red or Green LED Display
• Power 115 VAC, 230 VAC or 10–32 VDC
21
INFC ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: INFCP-5-1-2
A – B – C – D
A
B
C
D
Basic Unit
INFCP Process (DC Voltage and Current)
INFCS Strain Input
NIFCT Thermocouple
INFCDT Dual/Differential Thermocouple
INFCR RTD
INFCDR Dual/Differential RTD
INFCPH pH
INFCOR ORP
INFCOP pH/ORP
Power and Display
0
1
115 VAC, Red LED Display
230 VAC, Red LED Display
4
5
6
7
2
3
115 VAC, Green LED Display
230 VAC, Green LED Display
10–32 VDC, Red LED Display
10–32 VDC, Green LED Display
25–56 VDC, Red LED Display
25–56 VDC, Green LED Display
0
1
2
Relays
0
1
None
Two 6 Amp Form C Relays
Analog Output
None
Non-Isolated Analog
Isolated Analog Output
N/C
N/C
$ 70
N/C
$ 80
$ 90
INFCAC ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: INFCAC-0-0-1-0-V5
A – B – C – D – E – F
D
0
0
1
1
E
0
1
2
F
V5
C5
1
2
3
C
B
0
A
INFCAC
Basic Unit
AC Voltage and Current Controller
Power and LED Color
115 VAC, Red LED Display
230 VAC, Red LED Display
115 VAC, Green LED Display
230 VAC, Green LED Display
Control Output
No Control Output
Two 6A Form “C” Relays $
Analog Output
No Analog Output
4 to 20 mA or 0 to 10 VDC $
Communications
No Serial Output
Isolated RS-232
Isolated RS-485 Half Duplex $
Input Signal
0–750 VAC User Programmable
0–5 AAC User Programmable
$
N/C
N/C
N/C
N/C
70
N/C
80
N/C
$110
110
N/C
N/C
IDP ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: IDP-0
A – B
A
B
4
5
Basic Unit
IDP
IDT
IDpH
4-Digit Process Meter
4-Digit Thermocouple Meter
4-Digit pH Meter
1
2
Display/Power
0 Red/115 VAC
3
Red/230 VAC
Green/115 VAC
Green/230 VAC
Red/10–32 VDC
Green/10–32 VDC
$195
$225
$245
N/C
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Newport
Digital Panel Meters/Controllers
i8
These meters accept universal inputs—thermocouple, RTD, process voltage/current. Panel mounted, with NEMA-4 (IP65) front bezel, they offer multiple “firsts” for 1/8 DIN instruments:
• Display Changes Colors at Set Point
(Yellow, to Green, to Red)
• Fully Programmable Color Display and the Largest
Display (21 mm LEDs) of Any 1/8 DIN Instrument
• RS-232 and RS-485 Serial Communications (Optional) in One Instrument
• Built-In Excitation (10 or 24 VDC) is standard
Units also feature ±0.5°C accuracy, free Active X Controls software, extended
5-year warranty at no extra charge. Available as monitors only or with two control/alarm outputs.
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: i8-2-0-DC
A – B – C – D
A Base Units i800 Monitor only (no control outputs) 1/8 DIN $ 240 i8C00 Monitor only (no control outputs) 1/8 DIN Short Case *2 $ i8A00 Monitor with Isolated Analog Output 1/8 DIN $ 295 i8 Two control outputs 1/8 DIN $ 310 i8C i8A
Two control outputs 1/8 DIN Short Case *2 $ 355
Isolated Analog Output with two control outputs *1 365
B Control Output #1 & #2 Direct (Cool) or Reverse (Heat) Acting
22 Two solid state relays (SSR’s) N/C
23
24
SSR and relay: Form “C” SPDT
SSR and pulsed 10 Vdc(for use with external SSR)
N/C
33
34
44
2 Relays: Form “C” SPDT
Relay and pulsed (for use with external SSR)
Two pulsed 10 Vdc (for use with external SSR)
N/C
N/C
N/C
52
53
E1
C24
Analog Output (control or retransmission)
Analog Output and Relay
54 Analog Outputand Pulse
C Network Options
N/C
N/C
N/C
Ethernet with Embedded Web Server $ 55
Isolated RS-232 and RS-485 (MODBUS & ASCII) $0
C4EI Ethernet with Embedded Internet + Isolated RS-485 $
D Power Supply
AC
DC
Standard Power : 90 to 240 VAC/DC
10-34 Vac/dc (optional)
N/C
$ 25
*1 Not Available for the i8A Controller
*2 Not Available in the Compact Case
• 6-Digits
• NEMA-4 (IP65) Front Bezel
• Four Isolated Open Collector Outputs
• Peak and Valley Detection and Memory
• Digital Tare
• 1.5 to 11 or 24 VDC Sensor Excitation
▲
INFU
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: INFP-0-2-1-0-C2
A – B – C – D – E – F – G
A
B
C
D
E
F
G
Basic Unit
INFP
INFS
DINFW
INFT
INFU
Process (DC Voltage and Current)
Strain Gauge
Weight
Thermocouple and RTD
$ 545
$ 545
$ 595
$ 595
Universal Input (Process, Strain and Temp.) $ 645
Split Display–Insert Only If Required
Z Split Display (insert “Z” after INF in basic unit) $
1
2
3
Power and Display
0 115 VAC, Red LED
230 VAC, Red LED
115 VAC, Green LED
230 VAC, Green LED
N/C
N/C
N/C
N/C
$ 110
$ 110
4
5
10–32 VDC, Red LED
10–32 VDC, Green LED
Control Output
0 Four NPN Open Collectors
0
1
1
2
Isolated Parallel BCD
Two 7A Relays
3 Two 7A Relays and Two 1A Relay
Analog Output
None
Isolated Analog Output
N/C
$ 110
$ 75
$ 175
N/C
$ 110
1
2
Serial Output
0 None
Isolated RS-232
Isolated RS-485
Input Signal
Specify T/C, RTD, or DCV
N/C
$ 110
$ 110
N/C
22
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Simpson
Digital Meters/Controllers
23
Includes new temperature measurement models (H340)
• All Parameters Set from Front Panel
• 7 Segment 41
/
2 or 31
/
2
Digit Bright Red Display
• Screw Terminals for Easy Installation
• 1/8 DIN Shallow Depth Case
• Peak/Valley and Password Lockout
• Optional Plug-In Output and Excitation Cards
• Optional Plug-In Cards for One, Two or Four 5 Amp Relays
• NEMA 4X Rated Front Panel
SPECIFICATIONS
Display
Type:
Quantity:
J
Height:
Decimal Point:
AC:
Sensor Type
RTD Pt 100
K
E
T
Mechanical
7 segment, red LED
H335: 3 1
/
2 digit; H345: 4 1
/
2 digit; H340: 4 digit
0.56" (14.2 mm)
H335 and H340: 4-position, user programmable H345: 5- position, user programmable
5 Levels, user programmable Brightness:
Alarm Indicators: 4 LED indicators for up to four set points
Power Requirements
AC Voltages:
DC Voltages:
Accuracy @ 25°C:
120, 85-250 VAC @ 10VA
9–36 VDC @ 10 VA
DC: H335: 0.1% of input ±1 digit
H345: 0.05% of input ±1 digit
H335: 0.2% ±2 digits
H345: 0.1% ±2 digits
Accuracy Temperature Range
0.2% of input ±2 count -200°C to +200°C
0.2% of input ±2 counts -100°C to +760°C
0.2% of input ±2 counts -200°C to +1250°C
0.2% of input ±2 counts -100°C to +800°C
0.2% of input ±2 counts -200°C to +400°C
Bezel:
Depth:
Panel Cut-out:
Case Material:
Weight:
Temperature:
Sample Rate:
1
3.93 x 2.04 x .52" (98.8 x 51.8 x 13.2 mm)
3.24" (82.33mm) behind panel
/
8
DIN 3.62 x 1.77" (92 x 45 mm)
PBT-ABS
10 oz (283.5g)
0-50°C
10/sec
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
A – B – C – D – E – F
NEW
A Basic Temperature Meter
H340 4 digit Red LED
B Power Supply
1
2
4
120V AC
9-36V DC
85-250V AC
C Function Range
91
92
93
94
95
J Thermocouple
K Thermocouple
RTD, Pt100, 3-wire
E Thermocouple
T Thermocouple
D Analog Output
0 None
1
2
4-20 mA DC
0-10V DC
E 5 Amp Relays
2
4
0
1
None
One
Two
Four
F Excitation Output
0
1
2
None
12V DC (30mA max)
24V DC (30mA max)
▲
H335
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: H335-2-46-0-1-2
A – B – C – D – E – F
A
B
C
Basic Panel Meter
H335 3
1 /
2
digit Red LED
H345 4
1 /
2
digit Red LED
Power Supply
1 120VAC (3
1 /
2
digit only)
2 85-250 VAC (4
1
/
2
digit only)
12
13
14
15
3
4
3 9–36 VDC
85-250 VAC (3
1 /
2
digit only)
Function/Range
11 200mV DC 51 200mV AC TRMS
2V DC
20 VDC
200V DC
600V DC
52 2V AC TRMS
53 20V AC TRMS
54 200V AC TRMS
55 600 AC TRMS
D
E
F
21
22
23
24
25
26
200µA DC
2m ADC
20mA DC
200mA DC
2A DC
5A DC
61 200µA AC TRMS
62 2mA AC TRMS
63 20mA AC TRMS
64 200mA AC TRMS
65 2A AC TRMS
66 5A AC TRMS
31
32
33
34
35
200mV AC
2V AC
20V AC
200V AC
600V AC
41
42
43
44
45
200µA AC
2mA AC
20mA AC
200mA AC
2A AC
0
1
46 5A AC
Output Signal
2
None
4–20 mA DC Process
0–10 VDC Process
6 RS-485 (4
1
/
2 digit only)
5 Amp Relay Outputs
0 None
71 4-20mA DC Process
72 0-10V DC Process
81 200 Ohm
82 2k Ohm
83 20k Ohm
84 200k Ohm
1
2
4
One
Two
Four
1
2
Excitation Output (not available with Signal Output)
0 None
12V DC (30mA max)
24 DC (30mA max)
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Simpson
Digital Panel Meters
F35
M235
• Case Size: Standard 1/8 DIN
• Accuracy: ±0.2% (F35); ±0.05% (F45DC); ±0.5% (F45AC)
• Auto-Zero
• Choice of AC or DC Power Supplies
• Broad Range Scaling and Adjustable Zero Offset for Process Inputs
• User-Selectable Decimal Points
• Optional Excitation Output 12 VDC or 24 VDC
• Easy Installation Using Screw Terminals
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number
Order Example: F35-1-12-1
A – B – C – D
A
B
C
D
Basic Unit
F35
F45
3
4
1
1
Power Supply
/
2
-Digit Meter
/
2
-Digit Meter
3
4
1
2
120 VAC
220 VAC
9–32 VDC
120 VAC CE
Input Range
DC Voltage
200 mV 11
2V
20V
200V
750V
12
13
14
15
DC Current
AC Voltage
31
32
33
34
35
AC Current
0
1
2
200 µA 21
2 mA 22
20 mA 23
200 mA 24
2A
5A
25
26
Process
71 4–20 mADC
72 1–5 VDC
73 1–10 VDC
41
42
43
44
45
46
Temperature (F45 only)
80 J T/C
81 K T/C
82 S T/C
84
85
86
83 T T/C
Frequency
20–199.9 Hz
20–1999 Hz
91
92
90
RMS (F35)
Excitation Output (DC Input Only)
None
12 VDC
24 VDC
61
62
63
64
65
66
AC RMS
51
52
53
54
55
AC RMS
E T/C
R T/C mV DC
RTD PT 100
Sq. Wave (F35)
93
94
• Case Size: Standard 3/64 DIN Dimensions
• Accuracy: ±0.5% (M235); ±0.5% (M245)
• Minimum Depth Indicator—Less Than 2.5" (60 mm) of Space
• User-Selectable Decimal Point
• Optional Negative Image, Bright Red Backlighting
• Standard Screw Terminals
• 85V to 250 VAC Power or 9V to 32 VDC
Mini-Max—3/64 DIN, 3 1 ⁄
2 and 4 1 ⁄
2
Digit
AC and Process Indicators
Simpson’s Mini-Max AC Voltage/Current Indicators provide high quality, accuracy, and reliability in a compact 60 mm deep case.
Power:
Size:
SPECIFICATIONS
85V–250 VAC @ 40 Hz–440 Hz; or 9V–32 VDC
2.84W x 0.95 x 2.36" WHD (72 x 24 x 60 mm)
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: M235-1-0-11-0
A – B – C – D – E
A
B
C
D
E
Basic Unit
M235 3
1
/
2
-Digit LCD Meter
M245 4 1 /
2
-Digit LCD Meter
Display
0
1
Non-Backlit
Negative Red Backlight
Supply Voltage
0
2
85–250 VAC
9–32 VDC*
Function Range
11 200 mVDC
12 2 VDC
13 20 VDC
14 200 VDC
15 750 VDC
21 200 µADC
22 2 mADC
23 20 mADC
24 200 mADC
25 2 ADC
26 5 ADC
71 4–20 mADC
72 1–5 VDC
73 0–10 VDC
74 0–100 VDC
31 200 mVAC TRMS
32 2 VAC TRMS
33 20 VAC TRMS
34 200 VAC TRMS
35 750 VAC TRMS
41 200 µAAC TRMS
42 2 mAAC TRMS
43 20 mAAC TRMS
44 200 mAAC TRMS
45 2 AAC TRMS
46 5 AAC TRMS
81 20–199.9 Hz
82 20–1999 Hz
83 20–199.9 Hz Sq. Wave
84 20–1999 Hz Sq. Wave
Excitation Output (NA with Frequency)
0
1
2
None
12 VDC
24 VDC
* Not Available on Frequency (Hz) Meters
24
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Laurel
High Performance DPM
FEATURES
• ±99999 Display Span
• User Selectable Ranges
• 60 Readings Per Second
• Adaptive Averaging Filter
• 1/8 DIN, NEMA-4X Front
• 5, 10, 24V DC Excitation Out
OPTIONS (all outputs isolated)
• Dual Setpoint Controls Output
• Linearized 0-10V & 0-20 ma
Analog Transmitter Outputs
• RS-232 & RS-485 Data I/O
• Custom Curve Linearization
• Datalogging PC Software
Laureate™ DPMs offer exceptional flexibility in measuring DCV, ACV, DCA, ACA, temperature, weight, strain, process & pot follower.
Display
A-to-D Conversion
A-to-D rate
Display update
Accuracy at 25°C
DC error
Load Cell ..
True RMS
SPECIFICATIONS
Five 14.2 mm (.56”) high LED digits
60/s at 60 Hz, 50/s at 50 Hz
3.5/s at 60 Hz, 3/s at 50 Hz
< 0.01% FS ±1 ct
< 0.01% FS ±1 ct
< 0.1% FS (1-100%, 10 Hz-10 kHz)
CF = 2.4 at full scale
25
Noise Rejection
CMR, DC to 60 Hz 130 dB
NMR to 50/60Hz line 90 dB with min filtering
Transducer Excitation Output (std)
5V, 100 mA; 10V, 120 mA; 24V, 50 mA Output
Dual Relay Output (opt)
Contact relays .
10A @ 250 Vac, 8 A @ 24 Vdc
Solid state relays 0.12A @ 125 Vac, 0.25A @ 150 Vdc
Linerarized Analog Output (opt)
Level 0-20 mA or 4-20 mA plus 0-10 Vdc
Resolution
Environmental
12 bits (0.025%)
Operating temperature 0°C to 55°C
Humidity 95% RH at 40˚C, non-condensing
Data Communications (opt)
RS-485
BCD
Half or full duplex
6 decades parallel
ORDERING INFORMATION
Example: L10010DCV1
❑ Laureate Series
L Laureate Panel Meter
LW Laureate Weight Meter
❑ Main Board
1 DPM with green LEDs
2
3
DPM with red LEDs
Extended, green LEDs
4 Extended, red LEDs
Note: Extended capability for DPMs is required for custom curve linearization.
❑ Power
0 85-264 Vac/90-370 Vdc
1 9-37 Vdc/8-28 Vac
❑ Setpoint Output
0 None
1 Dual 10 A relays
❑ Analog Output
2
0
Dual solid state relays
None
❑ Digital Interface
1
0
0-20 mA & 0-10 V
None
1
2
3
RS-232
RS-485
BCD output
❑ Input Type
DC Volts
DCV1 200.00 mV
DCV2 2.0000 V
DCV3 20.000 V
DCV4 200.00 V
DCV5 660.0 V
DC Amperes
DCA1 2.0000 mA
DCA2 20.000 mA
DCA3 200.00 mA
DCA4 5.000 A
Process Signals
(4-20 mA, 0-5 V, etc.)
P
P1
4-20 mA = 0-10000
Custom Scaling
Strain Gage, Potentiometer
(4-wire ratio)
SG
SG1
0-200 mV = 0-20000
Custom Scaling
Note: The same DC signal conditioner board can be user configured for DC Volts, DC Amps, process, or strain.
100-Ohm Platinum RTDs P385C -202 to 850°C
P385F -331 to 1562°F
P392C -202 to 850°C
P392F -331 to 1562°F
Thermocouples
JC -210 to 760°C
JF -347 to 1400°F
KC -244 to 1372°C
KF -408 to 2501°F
TC -257 to 400°C
TF -430 to 752°F
EC -240 to 1000°C
EF -400 to 1830°F
NC -245 to 1300°C
NF -410 to 2370°F
SC -46 to 1768°C
SF -51 to 3214°F
RC -45 to 1768°C
RF -49 to 3213°F
Note: The same temperature signal conditioner board can be user configured for all T/C and RTD types
RMS Volts
RMS Amperes
RMV1 200.00 mV
RMV2 2.0000 V
RMV3 20.000 V
RMV4 200.00 V
RMV5 660.0 V
RMA1 2.0000 mA
RMA2 20.000 mA
RMA3 200.00 mA
RMA4 5.000 A
Note: The same AC RMS signal conditioner can be user-configured for AC Volts or Amps
Load Cells (6-wire ratio) WM1 -99,999 to +99,999
Note: Excitation is 10V DC for up to four 350Ω load cells in parallel
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Selco
Digital Panel Meters
Universal Type Digital Panel Meter
• UL, CSA & CE Approved
• Seven Output Choices
• Front Panel Membrane Set Buttons
• Eighteen Input Choices
• Available Two Setpoint Displays
• 90-264VAC or 9-60VDC Power Supply
• RS-232C/RS-485 Communications
• Industry Standard 1/8 DIN Size
• 8-Amp Setpoint Contact Relays
▲
A5000 Series
Main display:
Sub display:
Conversion rate:
Maximum display:
SPECIFICATIONS
4 Digit Red LED 14.2mm
Dual, Green LED 8mm (Hi & Lo setpoints)
12.5 times/sec
9999
Overrange indication: When input exceeds the maximum display, display OL or -OL
Zero display:
Decimal point:
External control:
Leading zero suppression
Settable to any digit position
Start/Hold, Peak Hold, Digital Zero
Operating temperature: 0 to 50°C, 35 to 85% RH
Storage temperature: -10 to 70°C less than 60% RH
Power supply: AC 100 to 240V ±10% (AC main unit)
DC 9 to 60V (DC main unit)
Power consumption: Approx. 4VA (at 100V)
Dimensions: 96mm x 48mm (H) x 147.5mm (D) DIN size
Dielectric strength (AC): Power supply/input terminal/output terminal 2000VAC/1 min.
Input terminal/output terminal 500VDC/1 min.
Case/power supply/input terminal/output terminal 2000VAC/1 min.
Dielectric strength (DC): Power supply/input terminal/output terminal 500VDC/1 min.
Input terminal/output terminal 500VDC/1 min.
Case/power supply/input terminal/output terminal 2000VAC/1 min.
Insulation resistance: 500VDC more than 100MΩ at the above terminals
Input:
AC Voltage:
AC Current:
Frequency:
40Hz to 1kHz
40Hz to 1kHz
0.1Hz to 200kHz
30V p-p Max.
Strain Gauge:
Adjustment Span:
Excitation:
Analog Output:
Setpoint Relays:
1 to 3 mV/V
5V@15mA, 10V@30mA
0-1V, 0-10V, 1-5V, 4-20mA
8A@240VAC, 30VDC Resistive
ORDERING INFORMATION
Example SE/A51/25-03
SE/A5
A B C
-
D
1
2
AC 100 - 240V (±10%)
DC 9 - 60V
1 Single (Main Display Only)
2 Multiple (Main & Sub Displays)
C Output
0
1
2
None
HI & LO setpoint
Analog output
D
5
6
3
4
7
RS-232C
RS-485
HI & LO setpoint + analog output
HI & LO setpoint + analog output + RS-232C
HI & LO setpoint + analog output + RS-485
Input
01 DC voltage (±99.99mV)
02 DC voltage (±999.9mV to ±600V)
03 DC current (±9.999mA to ±999.9mA)
04 AC voltage AVG (99.99mV to 9.999V)
05 AC voltage AVG (99.99V to 600V)
06 AC voltage RMS (99.99mV to 9.999V)
07 AC voltage RMS (99.99V to 600V)
08 AC current AVG (9.999mA to 999.9mA)
09 AC current AVG (5A)
10 AC current RMS (9.999mA to 999.9mA)
11 AC current RMS (5A)
12 Resistance (99.99Ω to 99.99KΩ)
13 Temperature (Thermocouple)
14 Temperature (RTD)
15 Frequency (Open collector, Logic, Magnet)
16 Frequency (50 to 500Vrms)
17 Strain gauge
18 1 to 5V, 4 to 20mA
2
3
2
3
1
4
3
Ranges
1
3
3
1
4
JKTSRB
Pt100
4
26
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Selco
Digital Panel Meters
4
1
/
2
Digit DC Voltmeter & Ammeter AP-141
• Low Cost 1/8 DIN Size
• Bright 0.56" LED (Red)
• 2V, 20V, 200V
Measurement Ranges
• 180~264V and
90~132V Power
4
1
/
2
Digit DC Voltmeter A2200
• 10mm (0.39") Red LEDs
• 1/32 DIN Case
• Isolated Power
NEW
SPECIFICATIONS
Input configuration:
Accuracy:
Single ended
±0.03% Rdg ±1 Digit
Input bias current:
Conversion rate:
(@ 18-28°C)
100pA (Typ.)
2.5/sec.
Normal mode rejection: More than 50dB (50/60Hz)
Zero stability:
Display:
Automatic zero adjustment
LED, 14.2mm 4 1
/
2
-digit
Polarity:
Decimal point:
Overrange indication:
A “-” is displayed automatically
Settable to any digit position
When input exceeds the maximum display,
0000 or - 0000 flashes
Power supply: 90~132VAC
180~264VAC
5VDC±5% 150mA (Max.)
24VDC±20% 35mA (Max.)
Operating temperature: 0~50°C, 35 to 85%RH
Power consumption:
Dimensions:
Weight:
Dielectric strength:
(with AC Power)
2VA
48mm(H)x96mm(W)x73mm(D) 1
/
8
DIN size
Approx. 160g (For AC), 90g (For DC)
Between input (Lo) terminal and earth, 500VDC Between power supply terminal and input terminal, earth, common,
Dielectric Strength
(with DC Power)
Insulation resistance: case, 1500VAC/1 min.
DC type; between input (Lo) and power supply (0V), 500VDC
Between input (Lo) and power supply (0V), 500VDC
DC500V 100MΩ at above terminals
DC Voltage Measurement
Model Range
AP-141-12 ±1.9999V
AP-141-13 ±19.999V
AP-141-14 ±199.99V
Maximum Input Input
Resolution Impedance Protection
100µV 100MΩ ±100V
1mV
10mV
1MΩ
1MΩ
±250V
±500V
SPECIFICATIONS
Accuracy:
Input configuration:
Conversion rate:
Overrange indication:
Decimal point :
± 0.1% of F.S.
Single Ended
2.5/sec
0000 or -0000 flashes
Front switch settable
External control:
Power:
Hold
5-24VDC, 100mA
Operating temperature: 0-50°C, 35-85% RH
Dimensions: 48mm(W) x 24mm(H) x 39.7mm(D)
Dielectric strength: 500VDC input to power
Model
A2200-12
A2200-13
A2200-14
Maximum
Reading
±1.999V
±19.99V
±199.9V
Input Input
Impedance
100MΩ
1MΩ
1MΩ
Replacement for AP-241A, AP-242A, AP-244A(no option)
Protection
±50V
±250V
±250V
A2200-12
A2200-13
A2200-14
ORDERING INFORMATION
2VDC Voltmeter, 4 1
/
2
Digit
20VDC Voltmeter, 4 1
/
2
Digit
200VDC Voltmeter, 4 1
/
2
Digit
3
1
/
2
Digit DC Meter A2100
• 10mm (0.39") Red LEDs
• 1/32 DIN Case
• Voltage or Current Input
SPECIFICATIONS
Voltage accuracy:
Current accuracy:
±0.1% of F.S
±0.2% of F.S.
Input configuration: Single Ended
Conversion rate: 2.5/sec
Overrange indication: 0000 or -0000 flashes
Decimal point : Front switch settable
External control: Hold
RH
35temperature: 85%
Dimensions: 48mm(W)
24mm(H) x 39.7mm(D)
Dielectric strength: 500VDC input to power
Range
-11
-12
-13
-14
-22
-23
-24
-25
Maximum
Reading
±199.9mV
±1.999V
±19.99V
±199.9V
±1.999mA
±19.99mA
±199.9mA
±1.999mA
Input Input
Impedance
100MΩ
100MΩ
1MΩ
1MΩ
100Ω
10Ω
1Ω
0.1Ω
Replacement for AP-200, AP-201A, AP-202A(no option)
Protection
±50V
±50V
±250V
±250V
±50mA
±150mA
±500mA
±3A
27
ORDERING INFORMATION
Example AP-141-12-1
AP - 141 A B
AP-141 4 1
/
2
Digit Voltmeter
A Range
12 ±2VDC Input
B
13 ±20VDC Input
14 ±200VDC Input
Power Supply
1
2
3
AC90~132V
AC180~264V
DC5V (Isolated)
4 DC24V (Isolated)
A21 A
-
B
ORDERING INFORMATION
A Power Supply
10 5VDC@60mA non-isolated
B Range
11 ±199.9mV
12 ±1.999V
13 ±19.99V
14 ±199.9V
22 ±1.999mA
23 ±19.99mA
24 ±199.9mA
25 ±1.999A
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Weschler
AC/DC Meters/Controllers
• ±1,999 and ±19,999 Count Displays
• Low-Cost Alarm Meter Option
• Dual Changeover Alarm Option
• Analog Retransmission Option
• 1/8 DIN Panel Format
• Clear, Bright Display
• Simple to Install
• Detachable, Coded Screw Terminals
• High-Noise EMI Immunity
• Isolated BCD Option
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: ACI-3-W-A-10-0
A – B – C – D – E
A
B
C
D
E
Basic Unit
ACI-3
ACI-4
ACI-4L
ACV-3
ACV-4
ACV-4L
DCI-3
3
4
1
1
/
2
-Digit Meter/Controller
/
2
-Digit Meter/Controller
4-Digit, Large Display (0.8" digits)
3 1 /
2
-Digit Meter/Controller
4 1 /
2
-Digit Meter/Controller
DCI-4
DCI-4L
DCV-3
DCV-4
DCV-4L
PRO-3
4
4-Digit, Large Display (0.8" Digits )
3
4
4-Digit, Large Display (0.8" digits)
3 1 /
2
-Digit Meter/Controller
1
1
1
/
2
-Digit Meter/Controller
/
2
-Digit Meter/Controller
/
2
-Digit Meter/Controller
4-Digit, Large Display (0.8" Digits )
3
1
/
2
-Digit Meter/Controller
PRO-4
PRO-4L
4 1 /
2
-Digit Meter/Controller
4-Digit, Large Display (0.8" Digits)
Load-3
Load-4
3
4
1 /
2
-Digit Meter/Controller
1 /
2
-Digit Meter/Controller
Load-4L 4-Digit, Large Display (0.8" Digits )
Output
X
Y
N
W
RS232
Supply Voltage
None
Analog Output
Dual Relays with Analog Output
Dual Relays, 7 Amps 250 VAC
RS-232 Serial Output
A 110 Volts
B 220 Volts
Input Range
DCI-3/ACI-3
7 19.99 mA
8 199.9 mA
9 1999 mA
10 5.00 AAC
DCV-3/ACV-3
1 199.9 mV
2 1.999V
3 19.99V
4 199.9V
5 600V
PRO-3 and PRO-4/4L
21 4–20 mADC
22 0–1 mADC
23 0–10 VDC
24 1–5 VDC
Load-3 and Load-4/4L
1 20 mV
2 100 mV
Options
0 None
1 Green Display
2 RMS Input Convertor
F 24 Volts AC
G 48 Volts AC
H 10-30 Volts DC
DCI-4/ACI-4
15 19.999 mA
16 199.99 mA
17 1999.9 mA
18 5.000 AAC
DCV-4/ACV-4
10 199.99 mV
11 1.9999V
12 19.999V
13 199.99V
14 600.0V
ACI-3
SPECIFICATIONS
Input Ranges
Model ACI-3, ACI-3X, ACI-3W, ACI-3Y: 0–19.99 mA, 0–199.9 mA,
0–1999 mA, 5.00A
Model ACI-4, ACI-4X, ACI-4W, ACI-4Y: 0–19.999 mA, 0–199.99 mA,
0–1999.9 mA, 5.000A
Model ACV-3, ACV-3X, ACV-3W: 0–1.999V, 0–19.99V,
Model ACV-4, ACV-4X, ACV-4W:
Model DCI-3, DCI-3X, DCI-3W:
Model DCI-4, DCI-4X, DCI-4W:
Model DCV-3, DCV-3X, DCV-3W:
Model DCV-4, DCV-4X, DCV-4W:
Model Pro-3, Pro-4:
Model Load-3, Load-4:
Accuracy
Of Range:
Display
Format:
0–199.9V, 500V
0–1.9999V, 0–19.999V,
0–199.99V, 500V
0–19.99 mA, 0–199.9 mA,
0–1.999A, 0–5.00A
0–19.999 mA, 0–199.99 mA,
0–1.9999A, 5.000A
0–199.9 mV, 0–1.999 mV,
0–19.99V, 0–199.9V
0–199.99 mV, 0–1.9999V,
0–19.999V, 0–199.99V, 500.0V
4 mA–20 mA, 0–1 mA, 0–10V, 1–5V
0–20 mV, 0–100 mV
1%, ±2 digits @ 75°F/25°C
7-segment, 0.56" (14.2 mm), red LED
Selectable by push-on jumper Decimal Point:
Alarm Output Option
Format: HI-LO (default), HI-HI, LO-LO, all failsafe
Analog Output Option
Outputs Available: 0–10V or 4 mA–20 mA, jumper-selectable, ±0.025% of range
0–500Ω
500Ω to infinity
4mA–20mA Load Limits:
0–10V Load Limits:
Power
Jumper Selectable:
Optional:
Size
Display Bezel:
Panel Cutout:
Environmental Limits
Operating Temperature:
Humidity:
115 VAC or 220 VAC, ±10% 3 VA
5 VDC, 12 VDC or 24 VDC
1/8 DIN (96 x 48 mm)
3.62” L x 1.77" W (92 x 45 mm)
32°F–125°F (0–50°C)
0–85% RH non-condensing
28
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
29
Weschler
Programmable Meter/Controller
Intuitive
▲
• Simplified Programming
• 8 Program Memories
• Display Filtering
• Last Digit Round-Up
• Optional NEMA (IP67) Front Cover (Call for Details)
• 10-Point Custom Linearization
This new and unique adjustment system offers unparalleled benefits. Now no more menus to scroll through—just go directly to the parameter you wish to adjust. Programming features include: Scaling,
Analog Output, Alarm Output, and 10-point Linearization.
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: Intuitive-AI-0-0-232-R-0
A – B – C – D – E – F – G
A
B
Basic Unit
Intuitive Meter/Controller
Input
C
F
U
AI
AV
DI
DV
AC Current
AC Voltage
DC Current
DC Voltage
Counter/Totalizer
Frequency/Rate
Process/Temp.
C Analog Output
0
ANI
None
4–20 mA
D Alarm Output
0
AL2
None
2 Alarms
E Serial Data Output
0
232
None
RS232
P
R
I
L
S
T
Integrator (Totalizer)
Loadcell
Process
Resistance
Serial Data
Temperature
ANV 0–10V
ANB -5 to +5V
SP 4 Alarms
422 RS422
485 RS485, addressable
DN Device Net
F Display Color
R
G
Red
Green
G Supply Voltage
0 95–265 VAC
DCPSU 11–30 VDC
National Meter
KW Hour Meters
Three Phase Energy & Demand Meters
• Six Digit kWh LCD Display
• L1, L2 & L3 Power Readings
• Three Digit V, A & kW Readout
• kWh Pulse Relay
• RS-485 Modbus RTU Output
• Use with CTs Rated to 10,000A
Displays kWhrs and kW Demand along with
Volts, Amps and real time kW per phase.
SPECIFICATIONS
▲
KW4000
Burden: Isolated CT circuit, burden 0.06VA
Operating Temperature: -10°F to 120°F, <95% RH non-condensing
Relay Output: SPST Form A, 240VAC@10A resistive
Dimensions:
Enclosure:
Connections:
Dimensions:
7.5"W x 8" H x 3.5" D
Surface mount, ABS plastic, NEMA 1
Screw terminals
5.6" W x 8.1" H x 3.5" D
• 3Ø Revenue Class Meter
• 9 Digit LED Display
• Field Programmable
• Memory Backup Without
Batteries
• Direct Energy Display
– No Multipliers
K4000PM
NEW
SPECIFICATIONS
Max Display:
Accuracy:
999,999,999 kWh
±0.5% ±2d
Burden: Isolated CT circuit, burden 0.75VA
Operating Temperature: -10°C to 50°C
Relay Output:
Contacts:
Indicator:
Enclosure:
Dimensions:
Standards:
Energy/alarm pulse, 1/sec max rate
440VAC, 10A, 2500VA resistive
Front panel LED
UL VO rated plastic, NEMA 1
3.78"W x 3.78" H x 3.3" D
CAT III 300V, Class II double insulated
ORDERING INFORMATION
CAT NO.
NM/KW4240
DESCRIPTION
120/208/240V 3Ø, 3 or 4 Wire, KWh/Demand Meter
NM/KW4480 277/480V 3Ø, 3 or 4 Wire, KWh/Demand Meter
NM/K4240PM 120/208/240V 3Ø, 3 or 4 Wire, KWh Meter
NM/K4480PM 277/480V 3Ø, 3 or 4 Wire, KWh Meter
400A solid core CTs included. Split core and larger sizes available. Single phase models also available.
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Yokogawa
AC Watt/VAR, Phase Angle and PF Meters
Click Here to
Order Online
• Suitable for Power Measurement of Distorted Waveforms
Such as a Thyristor Waveform
• Maintains Standard (IEC or ANSI 39.1) for Switchboard
Dielectric Strength and Circuit Usage Conditions
• Isolated Input and Output Circuits Via Isolation Transformer
• Automatic Frequency Compensation Circuit
• Can be Used in Unbalanced Circuits
• Size: 3.78 x 1.89 x 6.3" WHD
2355
35
2355/2356 SPECIFICATIONS
Accuracy: 0.1% @ ±10% input voltage variation
±0.25% of reading ±1 digit ±0.25% of FS for 45 Hz–65
Hz
Frequency Range: 40 Hz–500 Hz (2355 Watts); 45 Hz–65 Hz (2356 VARS)
Weight: Approx. 1.3 lb
Resolution:
Accuracy:
Frequency Range:
Weight:
2357 SPECIFICATIONS
Phase Angle
0.1°
0.1°
45 Hz–65 Hz
1.3 lb
Power Factor
0.001PF
±1.0°
45 Hz–65 Hz
1.3 lb
Voltage:
Current:
2355/2356 STANDARD RANGES
120V or 240 VRMS
(Up to 600 VAC available upon request)
1A or 5 ARMS (Up to 10A available upon request)
2355/2356 ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: 2355-10-40-04-1-0-FS (0-150.0)
A – B – C – D – E – F – G
A
B
C
D
E
F
G
2
3
0
1
4
5
Scaling
S
FS
Basic Unit
2355
2356
Watt Meter
VAR Meter
Function/Connections
10
20
30
40
Voltage Input
Single-Phase, 2-Wire
Single-Phase, 3-Wire
Three-Phase, 3-Wire
Three-Phase, 4-Wire**
40
70
120 Volt AC
240 Volt AC
Current Input
02 0–1 Amp AC
04 0–5 Amp AC
2
3
Display Multiplier
1 No Fixed Zero
1 Fixed Zero
2 Fixed Zero
Analog Output
No Output
1 mV/Digit
5 mV/Digit
1 to 5 VDC
0 to 1 mA DC
4 to 20 mA DC
Standard (input range and scale are the same)
Factory Scaling (custom—specify scaling)
**Specify auxiliary power of either 100, 117, 220, or 240 VAC for 3P4W only if analog output is selected.
Voltage:
Current:
2357 STANDARD RANGES
Phase Angle
60V–300V
1A–5A
Power Factor
60V–300V
1A–5A
2357 ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: 2357-10-40-04-10-FS (0-1800)
A – B – C – D – E – F
A
B
C
D
E
F
Basic Unit
2357 3 1 /
2
-Digit Meter
Function/Connections
10 Phase Angle 1P2W
11
20
21
30
31
40
41
Power Factor 1P2W
Phase Angle 1P3W
Power Factor 1P3W
Phase Angle 3P3W
Power Factor 3P3W
Phase Angle 3P4W
Power Factor 3P4W
Voltage Input
40
70
120 Volt AC
240 Volt AC
80 60 to 300 VAC (phase angle model only)
Current Input
02
04
0–1 Amp AC
0–5 Amp AC
Analog Output
10 No Output (power factor model only)
11
12
13
14
15
Scaling
1 mV/Digit
5 mV/Digit
1 to 5 VDC
0 to 1 mA DC
4 to 20 mA DC
S
FS
Standard (input range and scale are the same)
Factory Scaling (custom specify scaling)
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
NLS
Panel Meters
MINIATURE PANEL METERS
▲
PM349
• 0.1% Basic DC Accuracy
• Small Stackable Case
• Red, Green or Yellow Display
• Presettable Decimal Point
• MUX BCD Outputs
Case Size: 3.125"W x 1.375"H x 3.375"D
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: NL/PM349/L/G/CS/5/20V
D Reading
A – B – C – D – E – F
– Normal
A Model
S
Z
Scaled (specify value)
Offset (specify value)
NL/PM349 3 1
/
2 digit DC Voltmeter
NL/PM352 3 1
/
2 digit DC Voltmeter
CS
AC
Internal current shunt (specify range)
AC reading (PM352 only)
NL/PM452 4 1
/
2 digit DC Voltmeter
E Power
B Dislay Option
–
L
C LED Display Color
R
Y
G
0.3" LED digit height
Large 0.4" digits
Red
Yellow
Green
F
–
5
120
240
Range
200mV
2V
20V
20V
1000V
Normal
5VDC ±5%, 200mA with 120VAC adapter with 240VAC adapter
Rin
100MΩ (PM349 only)
1000MΩ
1MΩ
10MΩ
10MΩ
SHORT DEPTH DC VOLTMETERS
X37
▲
• Only
1
/
2
" behind panel
• 0.56" LED or 0.6" LCD
• 0.1% or 0.2% Accuracy
• Presettable Decimal Point
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: NL/X37/L/-/20V
A
B
C
A – B – C – D – E
Model
NL/X32 3 digit, LED (unipolar)
NL/X34 3 1
/
2 digit, LED (bipolar)
NL/X37 3 digit, LCD (bipolar)
Dislay Option
R
Y
G
L
–
Backlit LCD
Standard LCD or LED
LED Display Color
–
Red LED
Yellow LED
Green LED
LCD
D Reading
–
S
Z
CS
E Range
Normal
Scaled (specify value)
Offset (specify value)
Internal current shunt
(specify range)
X32 X34, X37
100mV 200mV
1V 2V
10V
100V
20V
200V
1000V 1000V
Rin
100MΩ
1MΩ
1MΩ
1MΩ
4MΩ
Power: 5VDC ±5%, 200mA
(6mA for X37)
Case Size: 4"W x 1.9"H x 1.1"D
1/8 DIN PANEL METERS
▲
RM350
• 0.1% or 0.2% Accuracy
• Amps, AC, Ω, Ratio Options
• Power Supply Options
• MUX BCD Outputs
Case Size: 4.0"W x 1.9"H x 4.5"D
A
B
C
D
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: NL/RM350/TB/-/G/AC/120/20V
A – B – C – D – E – F – G
Model
NL/RM350 3
1
/
2 digit, 0.56" LED
NL/RM351 3
1
/
2 digit, 0.6" LCD
NL/RM452 4
1
/
2 digit, 0.56" LED
NL/RM453 4
1
/
2 digit, 0.4" LCD
Connector (mating connector included)
TB
EC
Dislay Option
Terminal block
Edge connector
–
L
Standard
0.8" LED
(RM350 only)
Display Color
R
Y
G
–
Red LED
Yellow LED
Greeen LED
LCD
E
F
5
12
24
28
18
120
240
G Range
Reading
–
S
Z
CS
AC
Ohm
Power
200mV
2V
20V
20V
1000V
Normal
Scaled (specify value)
Offset (specify value)
Internal current shunt (specify range)
AC reading
Ohms reading
5VDC ±5%, 200mA
12VDC
24VDC
28VDC
18-34VDC isolated
120VAC
240VAC
Rin
100MΩ (RM3xx only)
1000MΩ
1MΩ
10MΩ
10MΩ
36
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Martel
Digital Panel Meters
900 Series
• LED or Backlit LCD
• Large 0.75” Digit Height
• ±200mV A/D
• IP67/NEMA 4X
Bezel Option
DPM950
DPM959
700 Series
•
1 /
2
" (or 2 x
1 /
4
")
Digit Height
• LED Backlight
• ±200mV A/D
• IP67/NEMA 4X
Bezel Option^
DPM750S
DPM702S
Dimensions:
Panel Cut-out:
Operating Temp:
LCD Backlight:
SPECIFICATIONS
2.99" x 1.73” x 0.51"
(76.0 x 44.0 x 15.0mm)
2.83" x 1.57” (72.0 x 40.0mm)
0°C to 50°C
50mA@5V (except DPM942)
ORDERING INFORMATION
Model Function Accuracy ±1d Supply VDC
DPM950
DPM950S
DPM595B
DCV*
DCV*
DCV*
DPM942
DPM970
4-20mA
ACV*
DTM910 °C/°F (Pt100 RTD)
DTM995 °C (Type K TC)
±0.05%
±0.05%
±0.05%
±0.05%
0.5%
1°C
1%
7.5-14
3.5-6.5
4.5-5.5
loop pwr
7.5-14
4.5-5.5
7.5-24
*Specify input range or internal shunt for current measurement.
37
35/65 Series
• Red LED, Green LED or LCD
• Voltage or Process Inputs
• Display Hold
• 5V power
35X
▲
35x Dimensions:
35x Panel Cut-out:
35x Mounting:
65x Dimensions:
65x Panel Cut-out:
65x Mounting:
Digit Height:
Accuracy:
Operating Temp:
Power:
DPM35R
DPM35G
DPM65
DPM65S
SPECIFICATIONS
2.57" x 1.10” x 0.77"
(64.0 x 28.0 x 16.8mm)
2.05" x 0.81” (52.1 x 20.6mm)
Window or bezel
2.3" x 1.1” x 0.71" (59 x 29 x 18.1mm)
2.22" x 1.04” (56.5 x 26.5mm)
Snap-in bezel
0.56" LED, 0.39" LCD
±0.05% ±1d typ.
0°C to 50°C
5VDC ±5%
ORDERING INFORMATION
Red LED DPM, differential input
Green LED DPM, differential input
LCD DPM, differential input
LCD DPM, single-ended input
-BL Dimensions:
-BL Panel Cut-out:
702S Dimensions:
702S Panel Cut-out:
Operating Temp:
LCD Backlight:
SPECIFICATIONS
2.57" x 1.39” x 1.36"
(65.2 x 35.2 x 32.0mm)
2.38" x 1.20” (60.5 x 30.5mm)
2.54" x 1.36” x 0.45"
(64.5 x 34.5 x 11.5mm)
2.44" x 1.26” (62.0 x 32.0mm)
0°C to 50°C
30mA@5V (except DPM702S)
ORDERING INFORMATION
Model
DPM750S-BL
DPM702S
DPM742-BL
Function
DCV*
DCV*
4-20mA
Accuracy ±1d
±0.1%
±0.05%
±0.1%
Supply VDC
3-15
3.5-7 loop pwr
*Specify input range or internal shunt for current measurement.
^IP67 bezel not available on DPM702S
EM32 Series
• 0.31" Digit Height
• Metal Bezel
• Mounts in 32.5mm
(1.28") Cutout
• IP67/NEMA 4X Front
Dimensions:
Accuracy:
Input:
Operating Temp:
Power:
EM32
▲
SPECIFICATIONS
1.5" dia x 0.93" (38.0 x 23.5mm) excluding pins
±0.1% ±1d typ.
±200mV DC*
0°C to 50°C
5VDC ±5% @500mA (50ma for LED)
ORDERING INFORMATION
EM32-1B
EM32-1B-LED
Circular LCD DPM
Circular LED DPM
*Specify other ranges or internal shunt for current measurement.
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Martel
Quick Mount Digital Panel Meters
QM130M—
Digital Wiper
Type DC Voltmeter
• 9 Segment LCD
• Color Scale
• Single Hole Mounting
QM100V—
2-Wire Voltmeter
• Monitoring of Voltage Systems
• 2-Wire Operation
• Reverse Polarity Protection
Easy to mount LCD Digital Panel
Meter ideal for monitoring 4 to 25 volt DC systems.
Low cost meter for when order of magnitude of the reading is more important that the value of the reading.
QM130M
▲
SPECIFICATIONS AND ORDERING INFORMATION
Full Scale Reading:
Resolution:
Supply Voltage:
Supply Current:
1 VDC
125 mVDC
5–12 VDC
1.5 mA
QM100V
▲
SPECIFICATIONS AND ORDERING INFORMATION
Input:
Accuracy:
Voltage Supply:
Current Supply:
QMV100
4.0 to 25.0 VDC
0.2% ± 1 count
3–50 VDC
3 mA
QMV100-40
4.0 to 40.0 VDC
0.4V ± 1 count
3-50 VDC
3mA
QM120C—
Elapsed Time Meter
• 9999.9 and 99999 Hour Ranges
• Reset and Trip/Total Inputs
• Leading Zero Blanking Input
• Pulse Output every 100 Hours
Easy to mount LCD digital elapsed hour meter which starts timing the moment it is powered up.
QM120C
▲
SPECIFICATIONS AND ORDERING INFORMATION
Resolution:
Operating Temp:
Supply Voltage:
Supply Current:
9999.9
99999
0–50°C
5–27 VDC
2.5 mA
0.1 hr
1.0 hr
QM140V— Voltage/Current Meter
• 200 mV Full Scale Reading
• Auto-zero, Auto-polarity
• Low Battery Warning
• Optional Screw Terminal Board
This model features 200 mV full scale input that can be configured to accept voltage up to 20 VDC and current up to 200 mA.
QM140V
▲
SPECIFICATIONS AND ORDERING INFORMATION
Input:
Accuracy:
Supply Voltage:
Supply Current:
200 mV, 2V, 20V
200 µA, 2 mA, 20 mA, 200 mA
0.05% ±1 count
7.5 to 15 VDC
150 µA
QM110T— Temperature Meter
• Internal Temperature Sensor
• 0.5" LCD Digit Height
• Readings in Degrees C or F
A digital temperature indicator with an internal temperature sensor or wire it for external sensors.
QM110T
SPECIFICATIONS AND ORDERING INFORMATION
Measuring Range:
Resolution:
Supply Voltage:
Internal Sensor
-10 to +50°C
-14 to +122°F
0.5°C
4–28 VDC
External Sensor
-20 to 220°C
-4 to 428°F
1°C
4–28 VDC
SPECIFICATIONS FOR ALL METERS
Character Height: 0.5" (12.5mm) except
0.35°(9mm) on QM120C
Operating Temperature: 0-50°C
Dimensions (W x H): 1.71" (43.50 mm) x 0.84" (21.40 mm)
Mounting:
Sealing:
7/32" (5.5 mm) hole
IP65 Front
38
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Weschler
Large Display Meters
• NEMA 4 Sealed
• Clear, Bright Display
• Remote Scaling and Brightness Setting
• Accepts Analog Signals Directly
• Fully Scalable, Includes Excitation
• Completely Self-Contained
• Serial Data O/P as Standard
SPECIFICATIONS
Standard Inputs
Scalable Inputs:
Excitation Supply:
Power Requirements
Standard Supply:
Optional Supply:
4–20 mA, 0–20 mA, 0–10V, 1V–5V
12.5 VDC @ up to 60 mA
95V–265V, DC to 400 Hz (20 watts)
12V–26V, DC to 400 Hz
ORDERING INFORMATION—ACCESSORIES
1700RP
DCPSU
RTD
TC
Remote Contact Closure Programmer
24 VDC Power Supply
3-Wire RTD Input**
Thermocouple Input Type K**
Weschler
Large Displays
A simple and affordable way to see and share important measurements over large distances:
2" (57mm) digits for viewing up to 65ft (20m)
4" (102mm) digits for viewing up to 130ft (40m)
Available in 3 input types, these meters can be configured from the front panel.
ER
P1700
NEW
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: P1758-B-1-0-21
A – B – C – D – E
A
B
C
D
E
21
20
23
24
Basic Unit
P1752
P1754
P1756
2" Digits
4" Digits
6" Digits
P1758 8" Digits
P17511 11" Digits
Case Color
B
W
Mounting
Black
White
1
2
3
Display
Panel
Wall
Suspension
0
DLV
Input Range
Normal Viewing
Daylight Viewing
4–20 mADC
0–20 mADC
0–10 VDC
1–5 VDC
ORDERING INFORMATION
A
B
C
To Order—Insert Number Code for Each Letter to
Select Catalog Number. Example ER4P-2
ER A B – C
Digit Size
2
4
C
S
Type
P
Mounting
2
3
2"
4"
Process Input
Count/rate Input
Slave
Wall
Suspension
39
Process (Type P)
Input:
Accuracy:
Display by:
Count (Type C)
Input:
Accuracy:
Slave (Type S)
Input:
Format:
Addressing:
4-20mA, 0-10V, 1-5V, scalable
±0.1% range ±1d @25°C
1, 2, 5, 10, 20, 50
NPN, PNP or contact closure
±0.05% range ±1d @25°C
RS232, RS422, RS485 or TTY
ASCII data from 300-9600 baud
00 to FF
SPECIFICATIONS
Reset:
Excitation:
Sealing:
Front panel or remote contact closure
24VDC, up to 30mA (except Slave)
Operating Temperature: 0-50°C, <95% RH non-condensing
Power: 95-265VAC, 11-30VDC
Dimensions: ER2 10.3x5.8x1.8" (260x140x45mm)
ER4 16.4x7.7x1.8" (415x195x45mm)
IP54 dust tight
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Newport
Two-Wire Loop-Powered Process Indicators
• Powered by 1–5 mA, 4–20 mA, or 10–50 mA Signal
• 2.5V Max Voltage Drop
• Display to ±1,999, ±19,990 or ±199,900
• 0.5" (12.7 mm) LCD
• 100 to 2,000 Count Span Adjust
• 2,000 Count Zero Suppression or Elevation
• Short 1/8 DIN Case
• Simple 2-Wire Hook Up
• Intrinsic Safety Certification (Optional)
• -40 to +85°C Operating Temperature (Optional)
558B
Made in the USA, these Newport LCD indicators provide extensive zero and span adjustment capability, so the units can read out directly in percent or in engineering units for process variables such as pressure, flow, temperature, or level. The liquid crystal display provides 3 1
/
2 active digits, two-jumper selectable dummy right hand zeroes, and five programmable decimal points.
The 508B series, in the NEMA-4 die-cast metal housing, is weatherproof to 5 PSI, with a temperature range of -40°C to
+85°C. The popular 558B series fits a 1/8 DIN panel cutout.
Electrical connections are via a three-pole male header connector on the circuit board and a removable mating plug-in socket connector with screw clamps, allowing for easy and reliable electrical connections.
FM
2P1A7.AX
558B
558B-ET
558B-IS1
ORDERING INFORMATION
Current Loop Indicator
Current Loop Indicator with Extended
Ambient Range (-40 to 85°C)
Intrinsic Safety Certification with
CENELEC EEx Label
Accessories
SPC18
SPC4
NEMA-4 Splash Proof Lens Cover
NEMA-4 Heavy Duty Splash Proof Lens Cover with Screw Clamp
Martel
Loop Powered Process Indicators
▲
LPM4200P
• 3
1
/
2
digit LCD Display
• Large 1 Inch Digits
• NEMA 4 & Panel Mount Enclosures
The LPM4200 Loop Powered Indicators are ideal for areas where local readout of a process variable is required and ease of viewing is important. Powered by the 4 to 20 mA loop, they drop only 2.7 volts from the loop being monitored. These meters are easy to install and can be scaled to read directly in the engineering units desired.
SPECIFICATIONS
Input:
Readout:
4-20 mA DC typical
3
1
/
2
digit LCD Display with switchable dummy zero
Decimal Point: Position is switch selectable
Accuracy: ±0.05% of full scale ±1 count
Span Range:
Zero Range:
100 to 2500 counts, switch selectable
±500 counts
Stability: 0.01%/°C
Temperature: Operating -20 to 70°C
Storage -30 to 80°C
Voltage Drop: 2.7V DC max.
Size:
NEMA 4
Panel Mount
6.3" W x 3.15" H x 3.15" D
5.67" W x 2.83" H x 2.83" D
(panel cutout 5.42" x 2.60")
ORDERING INFORMATION
LPM-4200N Loop Powered Indicator, NEMA 4
Enclosure
LPM-4200P Loop Powered Indicator, Panel Mount
Enclosure
40
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Weschler
DC Loop Powered Meters
• Powered Entirely from the Input Signal
• High Contrast LCD Display
• Clear Visibility in Direct Sunlight
• 1/8 DIN Case
• Detachable Screw Terminal Connectors
• Wide Ranging Zero and Span Control
• Selectable Decimal Point Location
• Simple to Install
• Low Cost
• X10 and X100 Add-On Zeros (Jumper Selectable)
Input Ranges:
Display Type:
Display Height:
Decimal Points:
Power Voltage:
Power Consumption:
CMRR:
Size:
Weight:
Case Material:
Operating Temperature:
Storage Temperature:
Relative Humidity:
SPECIFICATIONS
2-wire connection, 4 mA–20 mADC,
125Ω
10 mA–50 mADC, 50Ω, 1 mA–5 mADC
7-segment, HI-C LCD
12.7 mm 0.50"
Selectable internally
Line drop <2.5V DC
100 mW maximum
65 dB, DC to 450 Hz
1/8 DIN panel area and cutout
150 grams typically
94V–0 UL polycarbonate
-10°C to 50°C
-40°C to 85°C
Non-condensing 90% maximum @ 40°C
PRO
88-PRO
The 88-PRO is a low-cost, 3 1
/
2
-digit, scalable, process input indicator. It has an easy-to-read LCD display and detachable screw terminals. The basic 3 1
/
2
-digit offers 0 to 1,999 display range. This can be extended to 0 to 199,900 with both add-on zeroes enabled.
88-PRO
ORDERING INFORMATION
3 1 ⁄
2-
Digit Loop Powered Meter
41
Monarch
Panel Tachometers and Totalizer
ACT Series
ACT-1B
▲
• Universal Input from Optical, Infrared, Proximity and
Magnetic Sensors
• Direct TTL and 200 mV to 50 VAC Input Signals
• Selection of Sensors For All Environments
The ACT tachometers offer a simple RPM display or can be interfaced with data acquisition systems in your control room.
The ACT-1B/115 operates from a single pulse per revolution.
ACT-3/115 is front panel programmable for single or multiple pulses per revolution and for scaling. The ACT-3 is supplied with
NIST CERTIFICATE and has 2 alarm set points, offset analog voltage, current, TTL pulse and RS-232 outputs and offers a counter (totalizer) mode.
Speed Range
Accuracy
Display
Totalizer
Alarm Capability
Analog Outputs
Pulse Repeater
Dimensions
SPECIFICATIONS
ACT-1B/115
5 to 100,000 RPM
1 RPM
.56" H red LED
N/A
N/A
N/A
N/A
1/8 DIN by 4.5" deep
ACT-3/115
5 to 999,99 RPM
.001%, .0001 to 10 RPM
.56" H red LED
1-99,999
Two alarm set points. Front panel programmable as high or low.
Voltage(0–5 VDC), Current (4–20 mA)
Pulse Output,0–5V TTL compatible
1/8 DIN by 7" deep.
Compatible speed sensors on page 115
ACT-3/115
ACT-1B/115
ORDERING INFORMATION
Tach/Totalizer
Tach (1 Pulse/Rev)
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Laurel
Programmable Counters
FUNCTIONS
• Rate, Frequency, Period
• Total, Up/Down Total, Batch
• Time Interval, Stopwatch
• Quadrature
• Ratio / Draw
• Batch Controller
• Integrating Totalizer
• Phase Angle & Duty Cycle
FEATURES
• ±999,999 Display Span
• Scaling in Engineering Units
• Crystal Time Base Error <0.001%
• Sensor Excitation Output
• 1/8 DIN, NEMA-4X Front Panel
OPTIONS (all outputs isolated)
• Dual Setpoint Controls Output
• Analog Transmitter Outputs
• RS-232 & RS-485 Data I/O
• Custom Curve Linearization
• Datalogging PC Software
Exceptional flexibility is provided by advanced programmable features and by modular architecture with a choice of main boards
(basic or extended), signal conditioners (FR, VF or QD), power supplies, analog output, relay outputs, and data I/O.
SPECIFICATIONS
Display
Conversion Technique
Frequency measurement technique
Rate
Gate time
Scale Factor
Isolation
FR Signal Conditioner
Inputs
Channel A frequency
Channel B frequency
VF Signal Conditioner
Inputs
Span error
Span tempco
Zero tempco
QD Signal Conditioner
Six 14.2 mm (.56") high LED digits
1/period
Gate time + 30 ms + 2 input periods
Selectable 0 to 199.99 sec
±10 -10 to ±10 6
4.2 kVp (DC to 60 Hz)
AC, pulses from NPN or PNP transistors, contact closures, magnetic pickups
0 Hz to 1 MHz
0 Hz to 250 kHz
0-10 V, 0-1 mA, 4-20 mA
< 0.015% of full scale ±1 count
< 0.003% of reading/°C
< 0.001% of full scale/°C
Quadrature encoders to 250 kHz
Differential or single-ended
Zero index (Z-channel)
Inputs
Polarity
Error correction
Transducer Excitation Output (std)
Output
Isolation
Data Communications (opt)
RS-232
RS-485
BCD
Operating Temperature
5V, 100 mA; 10V, 120 mA; 24V, 50 mA
4.2 kVp per high voltage test
Full Duplex
Half or full duplex
6 decades parallel
0°C to 55°C
ORDERING INFORMATION
Example: L50010FR
❑ L
Laureate ™
❑ Main Board
5 with plug-in screw terminal connectors
Meter with green LEDs
6
7
Meter with red LEDs
Extended, green LEDs
8
❑ Power
0
Extended, red LEDs
85-264 Vac/90-370 Vdc
1 9-37 Vdc/8-28 Vac
❑ Setpoint Output
0 None
1 Dual 10 A relays
2 Dual solid state relays
❑ Analog Output or Batch Relay
0 None
1 0-20 mA, 0-10 V
2 Batch relay for FR
❑ Digital Interface
0 None
1
2
RS-232
RS-485
3
❑ Input Type
FR
BCD output
Frequency
With main boards 5 & 6: V-to-F converter for rate or square root of rate from different pressure or target type flow meters. With main boards
7 & 8: Above plus rate and total simultaneously, linearization of nonlinear inputs, ratio, draw, arithmetic functions (A*B, A/B, A/B-1, A+B, A-B), phase angle, stopwatch, up/down counting, batch counting.
With main boards 5 & 6: V-to-F converter for rate or square root of rate from differential pressure or target type flow meters. With main boards
7 & 8: Above plus rate and total simultaneously, linearization of nonlinear inputs, batch counting, 1/rate (time).
QD Quadrature
With main boards 5 & 6: Scalable to ±999,999 to read out position or length from shaft encoders.
QDR Quadrature Rate
With main boards 5 & 6; Scalable to ±999,999 to read out rate from shaft encoders.
42
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
Simpson
1/8 DIN Counter Totalizer, Rate/Totalizer/Batch
43
▲
S664
• NEMA-4X Front Panel
• Four Frequency Ranges Available (99 Hz, 999 Hz,
9 kHz, 35 kHz)
• Easy to Use (Install/Wire/Mount, Select Range, and Go)
• Bright Red LEDs for Easy Viewing
• Minimum Mounting Depth Required
• 120 or 240 VAC
• Optional Excitation Output 12 VDC @ 100 mA
• Modular Design
• Screw Terminals for Easy Installation
Display Type:
Power:
Operating Temp:
Size:
SPECIFICATIONS
7 segment, bright red LED, 0.56" H
120/240 VAC
0 to 55°C
3.6" W x 1.8" H x 3.24" D (92 x 48 x 82 mm)
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select
Catalog Number. Order Example: S664-1-1-0-0-0
A – B – C – D – E
–
F
A
B
C
D
E
F
Basic Unit
S664
Power Supply
1
2
Input Type
Frequency Counter
120 VAC
220 VAC
1
2
Standard Pulse Input
Quadrature input
Output Type
0 None
Excitation Output
0
1
None
12 VDC
Other
0 None
▲
S660
• NEMA-4X Front Panel
• Uses Words, Not Symbols for Easier Programming
• Bright Red LEDs for Easy Viewing
• Large, Tactile Buttons Can Be Pressed with Gloves On
• Standard 1/8 DIN Cutout
• Up to Two 5 Amp Relays Optional
• Optional Excitation Output 12 VDC
• Screw Terminals for Easy Installation
Display Type:
Power:
Operating Temp:
NMRR:
Size:
SPECIFICATIONS
7 segment, bright red LED, 0.56" H
120/240 VAC
0 to 55°C
60 dB @ 50/60 Hz
3.6" W x 1.8" H x 3.24" D (92 x 48 x 82 mm)
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select
Catalog Number. Order Example: S660-1-2-2-1-0
A – B – C – D – E
– F
A
B
C
D
E
F
Basic Unit
S660 Preset Up/Down Counter
S661 Preset Rate Counter
S662 Preset Totalizing/Batch Counter
S663 Preset Totalizing/Rate Counter
Power Supply
1
2
Input Type
120 VAC
220 VAC
1
2
Standard Pulse Input
Quadrature
Output Type
0
1
0
1
2
None
1 Mechanical Relay
2 Mechanical Relays
Excitation Output
None
12 VDC
Other
0 None
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
ATC Westcon
Counters
W3830 Series
6-Digit Indicator/Totalizer with Optional Outputs
W3870 Series
6-Digit Frequency Input Indicator/Totalizer with Optional Outputs
FEATURES
• Automatic Square Root
Extraction
• Logic Controlled Up/Down
Counter
• Preset Up Counter
• Preset Down Counter
• FLUME 5/2 Calculation
• WEIR 3/2 Calculation
SPECIFICATIONS
MODEL: RANGE: ACCURACY:
3830-23
3830-25
3830-27
0-5 VDC
0-10 VDC
4-20 mA
±0.08% reading, ±0.05% FS
±0.08% reading, ±0.05% FS
±0.08% reading, ±0.05% FS
OPERATING TEMP: 0°C to 50°C (32°F to 122°F)
FRONT COVER:
NEMA 4
CASE:
Anodized Aluminum
OPTIONAL OUTPUTS
OPTION C: 3 Form-C 5 amp relay outputs activate when
programmable high and low limits are exceeded.
Permits on-off control of external circuitry, or alarm status communication with other equipment.
OPTION H: 4 analog outputs, 0-5 VDC, ±5 VDC or 4-20 mA.
Accuracy is 0.35% of scaled range. Output signals are proportional to meter display.
OPTION T:
RS232C serial data communications interface at
9600 Baud rate.
OPTION V:
Totalizer pulse output. Solid-state relay (SSR).
Operating range: ±80V peak. continuous load current:
150 mA. Pulse width: 60mS (consult factory if faster output is required).
ORDERING INFORMATION
Model #:
Input
23
25
27
3830
0-5 VDC
0-10 VDC
4-20 mA
XX
Options
C
H
T
V
3 Relays
Analog
RS232
Totalizer Pulse Output
X X X X
SPECIFICATIONS
RANGE: User programmable
decimal, scale factors and insignificant zero blanking yield a display range of 0.00001 to
999999.
INPUT RESPONSE:
0.0005 to 99,999 Hz
PROTECTION: ±200 V peak
SENSITIVITY: TTL, CMOS or
contact compatible
PULSE WIDTH: 5 micro- seconds
minimum
TRIGGER MODE: Negative edge
of input pulse
INPUT IMPEDANCE: 12k ohms
FILTER/DEBOUNCE:
Front panel programmable digital filter
OPTIONAL OUTPUTS
Option C:
3 Form-C 5 amp relays activate when programmable high and low limits are exceeded. Permits on-off control of external circuitry, or alarm status communication with other equipment.
Option G:
Input amplifier, 30 mV peak input at 5 Hz to 99,999 Hz.
Option H:
4 analog outputs, 0-5 VDC, ±5 VDC or 4-20 mA. Accuracy is 0.35% of operating range. Output signals are assignable to rate and total.
Option S:
230 VAC Power.
Option T:
RS232C serial data communications interface at 9600
Baud rate.
Option X:
Screw terminal block connector. Accepts up to
#14 AWG wire.
ORDERING INFORMATION
PRICE
$ 225
Model #:
3870 X X X X X X
$ 60
65
140
N/C
60
26
Options
C
G
H
S
T
X
Relay Outputs
Input Amplifier
Analog Outputs
230 VAC Powered
RS232
Screw Terminal
44
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
KEP
Counter/Timer
KAL-DIN Series
KALD—8-Digit Counter
KALDTIME—7-Digit Timer
KALDRT—6-Digit Totalizer and 5-Digit Ratemeter
• UL, CSA Listed, CE Certified
• Meets NEMA-4X and IP65 Ratings
• Long Life Lithium Battery (KALD and KALDTIME only)
• Remote and Front Panel Reset
• Plug-On Adapter with Terminal Block and
AC Pulsing (KALD and KALDTIME only)
• Slow Speed Input for Contact Closures
• High Speed Input for Sinking Inputs from a
Max. of 24 VDC Without Module
The KAL-DIN series offers Count, Time, and Rate indication in a compact package. The KALD Counter and KALDTIME timer are self powered with an internal lithium battery. The KALDRT offers a 5-digit ratemeter and a
6-digit counter.
Digit Size:
Dimensions:
Panel Cutout:
Temp. Range:
Approvals: proved
SPECIFICATIONS
0.276" (7mm) high
1.89" W x 0.944" H x 1.36"D
(48 mm x 24 mm x 34.5 mm)
1.771" W x 0.886" H (45 x 22.5 mm)
14 to 140°F (-10 to 60°C)
UL File: E135458, CSA File: LR9602, CE Ap-
Weight:
Connection:
Sealing:
Power:
KALD:
KALDTIME:
KALDRT:
Display:
1.7 oz (48.2g)
5-pin, plug in connector with 9" (229 mm) leads supplied. Optional snap-on adaptors available
NEMA-4X/IP65
Internal lithium battery (life 10 yrs calculated)
Internal lithium battery (life 8 yrs calculated)
10 to 30 VDC, 10 mA
▲
KALD
▲
KALDTIME
KALDRT:
Signal Inputs:
Slow Speed Input:
High Speed Input:
KALD:
KALDRT:
45
Accuracy:
KALD:
KALDTIME:
KALDRT:
Resolutions:
KALDTIME1:
KALDTIME2:
KALDRT:
5-digit rate, 6-digit count, black
Contact Closure; negative level active
Low: <0.7 VDC, high: 3 to 24 VDC
Input Impedance: 1 Mohm pull-up
Minimum pulse length 15 mS, 30 Hz maximum
Minimum pulse length 50 µS, 10 kHz maximum
Min. pulse length 1.5 mS, 333 Hz max.
(RPM mode)
Min. pulse length 10 µS, 50 kHz max.
(freq. mode)
100 % @ rated count speed
±.003 % @ 25°C
RPM: 0.18%, Freq.: ±1 LSD
Minutes and seconds or seconds only
Hours and 100ths or hours and minutes
RPM or frequency meter
▲
KALDRT
KALD
KALDTIME1
KALDTIME2
KALDRT
ORDERING INFORMATION
8-Digit Counter
7-Digit Timer, Secs or Mins. and Secs
7-Digit Timer, Hrs and 100ths or Hrs and Mins
5-Digit Ratemeter with 6-Digit Totalizer
ACCESSORIES
KALDTB Terminal Block Adaptor
KALDAC/DC 5–240V AC/DC Input Adaptor for Counter
KALDTIMEAC/DC 5–240V AC/DC Input Adaptor for Timers
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
KEP
Counter/Timer
KEP
Totalizer/Rate Meter
Ratemeter/totalizer/process monitor from analog inputs
LCD preset add/subtract counter, timer, frequency meter
903K/904K Series
• 6-Digit Counter, Timer or
Frequency Meter
• 2 Preset Values
(Type 903K 1 Preset)
• Input Scaling
(0.0001 to 9.9999) Multiplier
• 2-Line LCD Display
• Count and Preset Range of -999999 to 999999
• Add or Subtract Count Control
• AC or DC Operation
• Secondary Preset Batch Counter (904K)
• 24 VDC to Power Peripherals
Display:
Preset:
SPECIFICATIONS
6-digit, 2-line, 7 segment LCD with sign
Type 904 two preset values
Type 903 one preset value
▲
904K
▲
INT69RT
Intellect-69 Series
• High/Low Scaling from Front Panel
• 2 Set Points Assignable To Rate or Total
• Display Rate (Pressure, Level, Watts, Etc.),
Peak and Valley and Integrated Total
• 0–5V, 0–10V, 1–5V, 4–20 mA or 0–20 mA Analog Input
• NEMA 4X/IP 65 Front Panel
• +24V Output for Peripherals
• RS-422/RS-232 Serial Communications
• 4–20 mA Output
• Square Root Extraction
• Optional Rate Per Day Feature
Supply voltage: 115 VAC, 230 VAC, 48 VAC or 24 VAC
Housing:
(tolerance ± 10%) or 11 to 30 VDC
48 x 48 mm DIN
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: INT69RT-A-L-1-A-C1
Protection: IP 65 (front)
A – B – C – D – E
Power Supply:
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number
Order Example: 904K-A-0-A
A – B – C – D
A
B
C
D
24 VDC, 80 mA
Basic Unit
903K Single Output
904K Dual Outputs
Input Voltage
A 115 VAC
D
E
B
C
Outputs
230 VAC
11 to 30 VDC
24 VAC
48 VAC
0
1
Options
—
A
Relay
Opto-Isolated collector and emitter
Blank if None
Backlit LCD Display (904K only)
A
B
C
D
E
Basic Unit
INT69RT Ratemeter/Totalizer
INT69R Ratemeter Only
INT69PM2 Process Monitor
A
B
INT69T
Displays from -19999 to +49999
Totalizer Only
Operating Voltage
110 VAC ±15% or 12 to 24 VDC
220 VAC ±15% or 12 to 24 VDC
L
S
Inputs
— Blank for INT69PM2
Linear (standard)
Square Law (optional)
A
D
C1
C2
Control Outputs
1 2-Open Collector Outputs (standard)
2 2–10 Amp Form C Relays (optional)
Options (Multiple Options Available)
Analog Output (4–20 mA)
Rate per Day, Hour or Minute
RS-232 communications
RS-422 communications
46
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]
WESCHLER INSTRUMENTS
KEP
Totalizer/Rate Meter
Low Cost, Pulse Input,
Totalizer & Ratemeter
Newport
6-Digit Rate Meter/Totalizer
6-digit ratemeter/totalizer offers user programming via the 5 front-panel keys. Scale factor may be programmed from -99,999 to 999,999 (any decimal point, multiply or divide), while offset may be programmed from -99,999 to
999,999 (any decimal point).
Programs are stored in non-volatile memory, with three levels of program lockout for security.
▲
INFCTRA
Optional features include Hi or Lo setpoints for control or alarm, plus
RS-232 communication. Fixed decimal point or autoranging is standard.
MINItrol Series
• CSA Approved
• Separate Scaling Factors for A and B Inputs
• Display Rate and Total
• Pulse Input—10 kHz Maximum
• Security Lockout
• RS-422/RS-232 Serial Communication
• NEMA-4X/IP65 Front Panel
• Separate Add/Subtract Simultaneous Inputs
• Quadrature and U/D Direction Control Inputs
• 30 mV Magnetic Pickup Inputs
• 4–20 mA or 0–20 mA Analog Output
▲
MRT
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: MRT-A-3-1
A – B – C – D
Functions:
Display:
Inputs
Type:
Level:
Frequency:
Excitation:
Accuracy:
Setpoints:
Alarm Outputs:
Communication:
Power:
Dimensions/Weight:
SPECIFICATIONS
Rate and totalize selected by menu
6-digit, 7-segment red LED display
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number. Order
Example: INFCTRA-0-1-1-0-R
Basic Unit
INFCTRA
Power and Display
0 115 VAC, Red LED
1 230 VAC, Red LED
2
3
115 VAC, Green LED
230 VAC, Green LED
Control Output
0 None
1 Dual 6 Amp
Analog Output
0 None
1 Analog Output
Serial Output
0 None
R
T
1 RS-232
Configuration
Ratemeter
Totalizer
Single input. TTL, CMOS, NPN open collector, contact closure and magnetic pickup compatible; selected by dip switch. Non-isolated
Max. 60V; min. 25 mV rms
30 kHz maximum
Regulated, 5.0, 8.2, or 12.5V selected by DIP switch, 100 mA max
± 1
/
2
LSD of total; 0.01% of the rate ± 1
/
2
LSD
Two, optional
Optional
RS-232, analog output, optional
230 ±15% VAC
1.9" H x 3.8" W x 6" D
(48 x 96 x 152 mm)/16 oz (454g)
1.8" H x 3.6" W (45 x 92 mm)
47
A Basic Unit
MRT 6-Digits, Counter/Ratemeter
MC2
MR2
6-Digits, Counter Only
5-Digits, Rate Only
B Operating Voltage
A 110 VAC ±15% or 12 to 15 VDC
B
C
220 VAC ±15% or 12 to 15 VDC
24 VAC ±15% or 12 to 15 VDC
C Count Inputs
3
3M
3MB
5
5M
9
Standard, 4–30 VDC Simultaneous Inputs
Mag. Input, Input A Only,
30mV Input (Input B, 4–30V)
Mag. Input, Inputs A and B, 30 mV input
4–30V Pulses on Input A,
4–30V Direction Control Input on Input B
30 mV Pulses on Input A,
4–30V Direction Control Input on Input B
Quadrature, Accepts 4–30V Pulses
9MB Quadrature, Accepts 30 mV Pulses (A and B)
D Control Outputs
1
2
RS-232 Communications
RS-422 Communications
A
CE
Analog Output (4–20/0–20 mA)
CE Approved Version
NOTE: RS-232/RS-422 and analog output options can not be combined.
Panel Cutout:
A – B – C – D – E
– F
D
A
B
C
E
F
WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]