null  null
AT Command Reference Manual
for the RC144ACi/ATi, RC144ACL/ATL,
RC144ACF/ATF, RC144ACFL/ATFL, and
RC144ACG Modem Families
(Preliminary)
Rockwell International
Digital Communications Division
©1995, Rockwell International
All Rights Reserved
Printed in U.S.A.
Order No. 883
Rev. 3, May 5, 1995
NOTICE
Information furnished by Rockwell International Corporation is believed to be accurate and reliable. However, no
responsibility is assumed by Rockwell International for its use, nor any infringement of patents or other rights of
third parties which may result from its use. No license is granted by implication or otherwise under any patent
rights of Rockwell International other than for circuitry embodied in Rockwell products. Rockwell International
r e s e r v e s t h e right to change circuitry at any time without notice. This document is subject to change without notice.
ConfigurACE is a trademark of Rockwell International.
MNP is a registered trademark of Microcom, Inc.
Hayes is a registered trademark of Hayes Microcomputer Products, Inc.
ii
883
AT Command Reference Manual
PREFACE
Revision 3 to this document incorporates the following:
1.
Revision of the Voice Commands Section to Voice/Audio Commands Section (Section 8) to support modem models
with speakerphone capability.
2.
Addition of Enable/Disable RPI and DTE Speed (+Hn) command to support ATi, ATF, and ATFL models.
3.
Addition of Enable/Disable Distinctive Ring (-SDR=n) command.
4.
Addition of Enable/Disable MNP10-EC (-SEC=n) command.
5.
Deletion of functions not supported in current release of MCU firmware.
6.
General corrections.
883
iii
This page is intentionally blank.
iv
883
AT Command Reference Manual
Table of Contents
1.
INTRODUCTION.....................................................................................................................................................................1-1
1.1.
OVERVIEW.........................................................................................................................................................1-1
1.1.1.
1.1.2.
1.1.3.
1.1.4.
1.2.
2.
REFERENCE DOCUMENTATION.................................................................................................................1-2
COMMAND SYNTAX.............................................................................................................................................................2-1
2.1.
DTE/DCE INTERCHANGE CIRCUITS..........................................................................................................2-1
2.2.
COMMAND SYNTAX AND GUIDELINES ......................................................................................................2-1
2.2.1.
2.2.2.
2.3.
Basic Command Syntax..........................................................................................................2-1
Extended Command Syntax...................................................................................................2-1
AT COMMAND SET...............................................................................................................................................................3-1
3.1.
AT COMMAND GUIDELINES..........................................................................................................................3-1
3.1.1.
3.1.2.
3.2.
AT Commands, DTE Adaption...............................................................................................3-1
AT Command Format..............................................................................................................3-1
AT COMMAND SET...........................................................................................................................................3-2
3.2.1.
883
DTE Commands ......................................................................................................................2-1
DTE Command Lines .............................................................................................................2-1
AT COMMAND GUIDELINES..........................................................................................................................2-1
2.3.1.
2.3.2.
3.
Command Syntax.....................................................................................................................1-1
Command Descriptions .........................................................................................................1-1
Call Progress and Blacklisting Paramete rs .......................................................................1-1
ConfigurACE II...........................................................................................................................1-1
AT Commands ..........................................................................................................................3-2
A/ - Re-execute Command .........................................................................................3-2
AT= x - Write to Selected S-Register .........................................................................3-2
AT? - Read Selected S-Register ...............................................................................3-2
A - Answer......................................................................................................................3-2
Bn - CCITT or Bell.........................................................................................................3-2
Cn - Carrier Control......................................................................................................3-3
Dn - Dial .........................................................................................................................3-3
En - Command Echo ...................................................................................................3-4
Fn - Select Line Modulation........................................................................................3-5
Hn - Disconnect (Hang-Up)........................................................................................3-6
In - Identification............................................................................................................3-6
Ln - Speaker Volume...................................................................................................3-6
Mn - Speaker Control...................................................................................................3-7
Nn - Automode Enable ................................................................................................3-7
On - Return to On-Line Data Mode............................................................................3-7
P - Set Pulse Dial Default ...........................................................................................3-8
Qn - Quiet Results Codes Control ............................................................................3-8
Sn - Read/Write S-Register ........................................................................................3-8
T - Set Tone Dial Default.............................................................................................3-9
Vn - Result Code Form................................................................................................3-9
Wn - Connect Message Control ................................................................................3-9
Xn - Extended Result Codes:...................................................................................3-10
Yn - Long Space Disconnect....................................................................................3-12
Zn - Soft Reset and Restore Profile ........................................................................3-12
v
Table of Contents (Continued)
3.2.2.
3.2.3.
3.2.4.
3.2.5.
3.2.6.
3.2.7.
3.3.
ERROR DETECTION AND DATA COMPRESSION COMMANDS..........................................................3-27
3.3.1.
3.3.2.
3.4.
AT& Commands .....................................................................................................................3-13
&Cn - RLSD (DCD) Option .......................................................................................3-13
&Dn - DTR Option.......................................................................................................3-13
&Fn - Restore Factory Configuration (Profile).......................................................3-13
&Gn - Select Guard Tone..........................................................................................3-14
&Jn - Telephone Jack Control..................................................................................3-14
&Kn - Flow Control .....................................................................................................3-14
&Ln - Leased Line Operation...................................................................................3-14
&Mn - Asynchronous/Synchronous Mode Selection............................................3-15
&Pn - Select Pulse Dial Make/Break Ratio............................................................3-15
&Qn - Sync/Async Mode.............................................................................................3-16
&Rn - RTS/CTS Option..............................................................................................3-17
&Sn - DSR Override ...................................................................................................3-17
&Tn - Test and Diagnostics ......................................................................................3-17
&V - Display Current Configuration and Stored Profiles .....................................3-18
&Wn - Store Current Configuration .........................................................................3-18
&Xn - Select Synchronous Clock Source ...............................................................3-19
&Yn - Designate a Default Reset Profile................................................................3-19
&Zn=x - Store Telephone Number ..........................................................................3-19
AT% Commands ....................................................................................................................3-20
%En - Enable/Disable Line Quality Monitor and Auto-Retrain or Fallback/Fall
Forward ........................................................................................................................3-20
%L - Line Signal Level...............................................................................................3-20
%Q - Line Signal Quality...........................................................................................3-20
%T - PTT Testing Utilities .........................................................................................3-21
AT\ Commands .......................................................................................................................3-22
\Kn - Break Control.....................................................................................................3-22
\Nn - Operating Mode.................................................................................................3-23
AT+ Commands .....................................................................................................................3-24
+Hn - Enable/Disable RPI and DTE Speed ..........................................................3-24
AT** Command.......................................................................................................................3-25
** - Download to Flash Memory...............................................................................3-25
AT- Commands ......................................................................................................................3-26
-SDR=n - Enable/Disable Distinctive Ring............................................................3-26
AT% Commands ....................................................................................................................3-27
%C - Enable/Disable Data Compression .............................................................3-27
AT\ Commands .......................................................................................................................3-27
\An - Select Maximum MNP Block Size ...................................................................3-27
\Bn - Transmit Break to Remote ..............................................................................3-27
MNP 10 COMMANDS.....................................................................................................................................3-28
3.4.1.
AT) Commands ......................................................................................................................3-28
)Mn - Enable Cellular Power Level Adjustment....................................................3-28
*Hn - Link Negotiation Speed ..................................................................................3-29
-Kn - MNP Extended Services ..................................................................................3-29
-Qn - Enable Fallback to V.22 bis/V.22...................................................................3-29
-SEC=n - Enable/Disable MNP10-EC....................................................................3-29
@Mn - Initial Cellular Power Level Setting.............................................................3-30
vi
883
AT Command Reference Manual
Table of Contents (Continued)
:E - Compromise Equalizer Enable Command ...................................................3-30
3.5.
W-CLASS COMMANDS .................................................................................................................................3-31
3.5.1.
3.6.
CALLER ID COMMANDS...............................................................................................................................3-33
3.6.1.
3.7.
AT#CID Command.................................................................................................................3-33
#CIDn - Caller ID ........................................................................................................3-33
Inquiries .......................................................................................................................3-33
Formatted Form Reporting.......................................................................................3-33
Example of Formatted Form Reporting..................................................................3-34
Unformatted Form Reporting ...................................................................................3-34
Example of Unformatted Form Reporting..............................................................3-34
CELLULAR COMMANDS ..............................................................................................................................3-35
3.7.1.
3.7.2.
3.7.3.
3.8.
AT* Commands ......................................................................................................................3-31
*B - Display Blacklisted Numbers ...........................................................................3-31
*D - Display Delayed Numbers ...............................................................................3-31
*NCn - Country Select................................................................................................3-32
Cellular Phone Drivers ..........................................................................................................3-35
Cellular Commands ..............................................................................................................3-35
^C2 - Download Cellular Phone Driver ..................................................................3-35
^I - Identify Cellular Phone Driver.............................................................................3-35
^T6 - Indicate Status of Cellular Phone ..................................................................3-36
Operation .................................................................................................................................3-36
Modem Configuration ................................................................................................3-36
Cellular Phone Configuration ..................................................................................3-37
AT COMMAND RESULT CODES.................................................................................................................3-38
0- OK.............................................................................................................................3-38
1- CONNECT...............................................................................................................3-38
2- RING.........................................................................................................................3-38
3- NO CARRIER..........................................................................................................3-38
4- ERROR ....................................................................................................................3-38
5- CONNECT 1200 ....................................................................................................3-38
6- NO DIALTONE........................................................................................................3-38
7- BUSY........................................................................................................................3-39
8- NO ANSWER ..........................................................................................................3-39
9- CONNECT 0600 ....................................................................................................3-39
10- CONNECT 2400..................................................................................................3-39
11- CONNECT 4800..................................................................................................3-39
12- CONNECT 9600..................................................................................................3-39
13- CONNECT 7200..................................................................................................3-39
14- CONNECT 12000................................................................................................3-39
15- CONNECT 14400................................................................................................3-39
16- CONNECT 19200................................................................................................3-39
17- CONNECT 38400................................................................................................3-40
18- CONNECT 57600................................................................................................3-40
19- CONNECT 115200 .............................................................................................3-40
22- CONNECT 75TX/1200RX..................................................................................3-40
23- CONNECT 1200TX/75RX..................................................................................3-40
24- DELAYED..............................................................................................................3-40
883
vii
Table of Contents (Continued)
32- BLACKLISTED .....................................................................................................3-40
33- FAX .........................................................................................................................3-40
35- DATA......................................................................................................................3-40
40- CARRIER 300 ......................................................................................................3-40
44- CARRIER 1200/75 ..............................................................................................3-40
45- CARRIER 75/1200 ..............................................................................................3-40
46- CARRIER 1200....................................................................................................3-40
47- CARRIER 2400....................................................................................................3-40
48- CARRIER 4800....................................................................................................3-40
49- CARRIER 7200....................................................................................................3-41
50- CARRIER 9600....................................................................................................3-41
51- CARRIER 12000..................................................................................................3-41
52- CARRIER 14400..................................................................................................3-41
66- COMPRESSION: CLASS 5 ................................................................................3-41
67- COMPRESSION: V.42 bis ..................................................................................3-41
69- COMPRESSION: NONE.....................................................................................3-41
70- PROTOCOL: NONE ............................................................................................3-41
77- PROTOCOL: LAPM..............................................................................................3-41
80- PROTOCOL: ALT.................................................................................................3-41
81- PROTOCOL: ALT-CELLULAR...........................................................................3-41
+F4- +FCERROR........................................................................................................3-41
4.
S-REGISTERS ........................................................................................................................................................................4-1
4.1.
FACTORY DEFAULTS .....................................................................................................................................4-1
4.2.
S-REGISTER DEFINITIONS...........................................................................................................................4-4
S0 - Number of Rings to Auto-Answer .....................................................................4-4
S1 - Ring Counter.........................................................................................................4-4
S2 - Escape Character ................................................................................................4-4
S3 - Carriage Return Character.................................................................................4-4
S4 - Line Feed Character............................................................................................4-4
S5 - Backspace Character..........................................................................................4-4
S6 - Wait Time for Dial Tone Before Blind Dialing, or After “W” Dial
Modifier (W-Class Models).........................................................................................4-5
S7 - Wait Time For Carrier After Dial, For Silence, or For Dial Tone
After “W” Dial Modifier (US Models)...........................................................................4-5
S8 - Pause Time For Dial Delay................................................................................4-5
S9 - Carrier Detect Response Time.........................................................................4-5
S10 - Lost Carrier To Hang Up Delay.......................................................................4-5
S11 - DTMF Tone Duration.........................................................................................4-5
S12 - Escape Prompt Delay (EPD)...........................................................................4-6
S13 - Reserved .............................................................................................................4-6
S14 - General Bit Mapped Options Status...............................................................4-6
S15 - Reserved .............................................................................................................4-6
S16 - General Bit Mapped Test Options Status......................................................4-7
S17 - Reserved .............................................................................................................4-7
S18 - Test Timer ...........................................................................................................4-7
S19 - AutoSync Bit Mapped Options .........................................................................4-8
S20 - AutoSync HDLC Address or BSC Sync Character.......................................4-8
viii
883
AT Command Reference Manual
Table of Contents (Continued)
S21 - V.24/General Bit Mapped Options Status......................................................4-9
S22 - Speaker/Results Bit Mapped Options Status.............................................4-10
S23 - General Bit Mapped Options Status.............................................................4-11
S24 - Sleep Inactivity Timer ......................................................................................4-11
S25 - Delay To DTR ...................................................................................................4-11
S26 - RTS to CTS Delay............................................................................................4-11
S27 - Bit Mapped Options Status ............................................................................4-12
S28 - Bit Mapped Options Status ............................................................................4-13
S29 - Flash Dial Modifier Time ................................................................................4-13
S30 - Disconnect Inactivity Timer ............................................................................4-13
S31 - Bit Mapped Options Status ............................................................................4-14
S32 - XON Character .................................................................................................4-14
S33 - XOFF Character................................................................................................4-14
S34-S35 - Reserved ..................................................................................................4-14
S36 - LAPM Failure Control ......................................................................................4-14
S37 - Desired Line Connection Speed ..................................................................4-15
S38 - Delay Before Forced Hang Up ......................................................................4-16
S39 - Flow Control Bit Mapped Options Status ....................................................4-16
S40 - General Bit Mapped Options Status.............................................................4-17
S41 - General Bit Mapped Options Status.............................................................4-18
S46 - Data Compression Control ...........................................................................4-18
S48 - V.42 Negotiation Action...................................................................................4-18
S82 - Break Handling Options .................................................................................4-19
S86 - Call Failure Reason Code .............................................................................4-19
S91 - PSTN Transmit Attenuation Level.................................................................4-19
S92 - Fax Transmit Attenuation Level.....................................................................4-19
S95 - Extended Result Codes .................................................................................4-20
S201 - Cellular Transmit Level ................................................................................4-20
5.
FAX CLASS 1 COMMANDS.................................................................................................................................................5-1
5.1.
FAX I/O PROCESSING.....................................................................................................................................5-1
5.1.1.
5.1.2.
5.1.3.
5.1.4.
5.1.5.
5.1.6.
5.1.7.
5.1.8.
5.1.9.
5.2.
DTE-to-Modem Transmit Data Stream ................................................................................5-1
Modem-to-DTE Receive Data Stream ..................................................................................5-1
Fax Mode Selection..................................................................................................................5-1
Fax Origination..........................................................................................................................5-1
Fax Answering...........................................................................................................................5-2
Fax Control Transmission ......................................................................................................5-2
Fax Control Reception.............................................................................................................5-2
Fax Data Transmission...........................................................................................................5-3
Fax Data Reception..................................................................................................................5-3
COMMANDS ......................................................................................................................................................5-4
+FCLASS=n - Select Service Class ..........................................................................5-4
+F<command>? - Report Active Configuration ......................................................5-4
+F<command>=? - Report Operating Capabilities ...............................................5-4
+FAE=n - Data/Fax Auto Answer................................................................................5-4
+FTS=n - Stop Transmission and Wait....................................................................5-4
+FRS=n - Receive Silence..........................................................................................5-4
+FTM=n - Transmit Data .............................................................................................5-5
883
ix
Table of Contents (Continued)
+FRM=n - Receive Data ..............................................................................................5-5
+FTH=n - Transmit Data with HDLC Framing ........................................................5-6
+FRH=n - Receive Data with HDLC Framing .........................................................5-6
5.3.
6.
EXAMPLES.........................................................................................................................................................5-6
FAX CLASS 2 COMMANDS.................................................................................................................................................6-1
6.1.
COMMAND SYNTAX AND GUIDELINES ......................................................................................................6-1
6.1.1.
6.1.2.
6.1.3.
6.1.4.
6.1.5.
6.1.6.
6.2.
SERVICE CLASS 2 IDENTIFICATION AND SELECTION..........................................................................6-4
6.2.1.
6.2.2.
6.2.3.
6.3.
DTE Commands ......................................................................................................................6-1
DTE Command Lines .................................................................................................6-1
Facsimile Command Syntax......................................................................................6-1
Serial Port Speed and Flow Control .....................................................................................6-3
Data Stream Termination ...........................................................................................6-3
DTE to DCE Streams...................................................................................................6-3
DCE to DTE Streams...................................................................................................6-3
Auto Answer...............................................................................................................................6-3
Identification of T.30 Options..................................................................................................6-3
Session Status Reporting ......................................................................................................6-4
Procedure Interrupt Negotiation ............................................................................................6-4
+FMFR?, Request Manufacturer Identification....................................................................6-4
+FMDL?, Identify Product Model ............................................................................................6-4
+FREV?, Identify Product Revision........................................................................................6-4
SERVICE CLASS 2 ACTION COMMANDS...................................................................................................6-4
6.3.1.
6.3.2.
6.3.3.
6.3.4.
6.3.5.
6.3.6.
6.3.7.
6.3.8.
6.3.9.
ATD, Originate a Call ...............................................................................................................6-5
ATA, Answer a Call...................................................................................................................6-5
Manual Call Answer.....................................................................................................6-5
Automatic Answer.........................................................................................................6-5
Connection as a Data Modem ...................................................................................6-5
+FDT, Data Transmission ......................................................................................................6-6
Initiate Page Transmission ........................................................................................6-6
Continue a Page...........................................................................................................6-6
Phase C Data Framing ...............................................................................................6-6
Phase C Data Format..................................................................................................6-6
<CAN>, Escape from Transmission ........................................................................6-6
+FET, Transmit Page Punctuation........................................................................................6-8
End a Page ....................................................................................................................6-8
+FDR, Begin or Continue Phase C Receive Data .............................................................6-9
Initiate Document Reception......................................................................................6-9
Continue Document Reception ...............................................................................6-10
Phase C Data Framing .............................................................................................6-10
Phase C Data Format................................................................................................6-10
<CAN>, Escape from Reception .............................................................................6-10
+FK, Session Termination....................................................................................................6-10
+FCIG, Set Polling ID .............................................................................................................6-11
+FLPL, Indicate a Document for Polling ............................................................................6-11
+FSPL, Enable Polling ..........................................................................................................6-11
x
883
AT Command Reference Manual
Table of Contents (Continued)
6.4.
SERVICE CLASS 2 DCE RESPONSES.....................................................................................................6-13
6.4.1.
6.4.2.
6.4.3.
6.4.4.
6.4.5.
6.4.6.
6.4.7.
6.4.8.
6.4.9.
6.4.10.
6.4.11.
6.4.12.
6.4.13.
6.5.
SERVICE CLASS 2 PARAMETERS.............................................................................................................6-16
6.5.1.
6.5.2.
6.5.3.
6.5.4.
6.5.5.
6.5.6.
6.5.7.
6.5.8.
6.5.9.
6.5.10.
6.5.11.
6.5.12.
6.6.
7.
+FDCC, DCE Capabilities Parameters .............................................................................6-16
+FDIS, Current Sessions Capabilities Parameters ........................................................6-16
+FDCS, Current Session Results Parameters ................................................................6-17
+FLID=, Local ID String .........................................................................................................6-18
+FCR, Capability to Receive.................................................................................................6-18
+FPTS=, Page Transfer Status ............................................................................................6-18
+FCQ, Copy Quality Checking..............................................................................................6-18
+FPHCTO, DTE Phase C Response Time-out................................................................6-18
+FAXERR, T.30 Session Error Report................................................................................6-19
+FBOR, Data Bit Order ..........................................................................................................6-19
+FAA, Answer Parameter......................................................................................................6-19
+FBUF?, Buffer Size ...............................................................................................................6-20
EXAMPLE SESSIONS....................................................................................................................................6-20
VOICE/AUDIO COMMANDS.................................................................................................................................................7-1
7.1.
VOICE/AUDIO SUBMODES ............................................................................................................................7-1
7.1.1.
7.1.2.
7.1.3.
7.2.
Online Voice Command Mode...............................................................................................7-1
Voice Receive Mode.................................................................................................................7-1
Voice Transmit Mode...............................................................................................................7-2
VOICE/AUDIO CAPABILITIES.........................................................................................................................7-2
7.2.1.
7.2.2.
7.2.3.
7.2.4.
7.2.5.
7.2.6.
883
+FCON, Facsimile Connection Response .......................................................................6-13
+FDCS:, Report Current Session Capabilities .................................................................6-13
+FDIS:, Report Remote Station Capabilities ....................................................................6-13
+FCFR, Indicate Confirmation to Receive .........................................................................6-13
+FTSI:, Report the Transmit Station ID...............................................................................6-13
+FCSI:, Report the Called Station ID ..................................................................................6-13
+FPTS:, Receive Page Transfer Status..............................................................................6-14
+FET:, Post Page Message Response .............................................................................6-14
+FPTS:, Transmit Page Transfer Status ............................................................................6-14
+FHNG:, Call Termination with Status ...............................................................................6-14
+FCIG:, Report the Polled Station ID ..................................................................................6-15
+FDTC:, Report the Polled Station Capabilities ...............................................................6-15
+FPOLL, Indicate Polling Request......................................................................................6-15
Call Establishment - Originate ..............................................................................................7-2
Directed Originate (Dial as a specific modem type)..............................................7-2
Adaptive Originate (Dial with Voice/Data/Fax Discrimination) .............................7-2
Call Establishment - Answer .................................................................................................7-3
Directed Answer (Answer as a specific modem type) ..........................................7-3
Adaptive Answer (Answer with Voice/Data/Fax Discrimination) ..........................7-3
Voice/Audio Data Transfer......................................................................................................7-4
Tone and Status Monitoring — Shielded <DLE> Statuses ..............................................7-4
Shielded <DLE> Commands from the DTE .......................................................................7-6
Voice Record.............................................................................................................................7-8
xi
Table of Contents (Continued)
7.2.7.
7.2.8.
7.2.9.
7.2.10.
7.3.
Voice Playback..........................................................................................................................7-8
Volume Adjustment During Record ..........................................................................7-8
Volume Adjustment During Playback.......................................................................7-8
Voice Call Termination............................................................................................................7-9
Local Disconnect..........................................................................................................7-9
Remote Disconnect Detection...................................................................................7-9
Mode Switching.........................................................................................................................7-9
Voice to Fax....................................................................................................................7-9
Unsuccessful Fax Connection Attempt to Voice.....................................................7-9
Voice to Data .................................................................................................................7-9
Unsuccessful Data Connection Attempt to Voice ..................................................7-9
Caller ID .....................................................................................................................................7-9
AT VOICE COMMAND SUMMARY................................................................................................................7-10
7.3.1.
7.3.2.
Global AT Command Set Extensions.................................................................................7-10
ATA - Answering in Voice/Audio...............................................................................7-11
ATD - Dial Command in Voice/Audio......................................................................7-11
ATH - Hang Up in Voice/Audio .................................................................................7-11
ATZ - Reset from Voice Mode...................................................................................7-12
#BDR - Select Baud Rate (Turn off Autobaud)......................................................7-12
#CID - Enable Caller ID Detection and Select Reporting Format.....................7-12
#CLS - Select Data, Fax, or Voice/Audio ................................................................7-13
#MDL? - Identify Model ..............................................................................................7-13
#MFR? - Identify Manufacturer..................................................................................7-13
#REV? - Identify Revision Level...............................................................................7-13
AT#V Commands Enabled Only in Voice Mode (#CLS=8).............................................7-14
#TL- Audio Output Transmit Level...........................................................................7-14
#VBQ? - Query Buffer Size ........................................................................................7-14
#VBS - Bits Per Sample ............................................................................................7-14
#VBT - Beep Tone Timer...........................................................................................7-15
#VCI? - Identify Compression Method....................................................................7-15
#VLS - Voice Line Select...........................................................................................7-16
#VRA - Ringback Goes Away Timer (Originate) ...................................................7-18
#VRN - Ringback Never Came Timer (Originate) ................................................7-18
#VRX - Voice Receive ................................................................................................7-18
#VSD - Enable Silence Deletion (Voice Receive) [ADPCM] ...............................7-19
#VSK - Buffer Skid Setting.........................................................................................7-19
#VSP - Silence Detection Period (Voice Receive) [ADPCM]...............................7-20
#VSR - Sampling Rate Selection ............................................................................7-20
#VSS - Silence Detection Tuner (Voice Receive) [ADPCM] ................................7-21
#VTD - DTMF Tone Reporting..................................................................................7-22
#VTM - Enable Timing Mark Placement.................................................................7-23
#VTS - Generate Tone Signals (Online Voice Command).................................7-23
#VTX - Voice Transmit ...............................................................................................7-24
#VGT - Set Playback Volume in the Command State..........................................7-24
<DLE><u> and <DLE><d> - Set Playback Volume in the Data State ..............7-24
xii
883
AT Command Reference Manual
Table of Contents (Continued)
7.3.3.
7.3.4.
7.4.
Speakerphone Commands .................................................................................................7-24
Originating a Call in Speakerphone Mode ............................................................7-25
Answering a Call in Speakerphone Mode .............................................................7-25
Muting the Local Handset During Phone Conversation - Music on Hold ........7-25
Recording a Handset Conversation on the Phone Line.....................................7-26
Recording/Playback from Handset through Sound Chip ...................................7-26
#SPK Parameter.........................................................................................................7-26
Room Monitor..............................................................................................................7-27
Switching Between #VLS Settings:.........................................................................7-27
Reporting of Local Handset Status.........................................................................7-27
Using VoiceView with Speakerphone, Headset, and Handset modes .......................7-28
Using Modem as Dialer Prior to VoiceView Mode ...............................................7-29
S-REGISTERS ................................................................................................................................................7-30
S30 - Disconnect Inactivity Timer ............................................................................7-30
A.
B.
883
7.5.
RESULT CODES FOR VOICE OPERATION..............................................................................................7-30
7.6.
EXAMPLES OF VOICE OPERATION ...........................................................................................................7-30
AT COMMAND SET SUMMARY..........................................................................................................................................A-1
A.1.
BASIC AT COMMANDS....................................................................................................................................A-1
A.2.
ECC COMMANDS.............................................................................................................................................A-4
A.3.
MNP 10 COMMANDS.......................................................................................................................................A-5
A.4.
W-CLASS COMMANDS ...................................................................................................................................A-5
A.5.
CALLER ID COMMANDS.................................................................................................................................A-5
A.6.
FAX CLASS 1 .....................................................................................................................................................A-6
A.7.
FAX CLASS 2 .....................................................................................................................................................A-6
A.8.
VOICE/AUDIO COMMANDS............................................................................................................................A-7
A.9.
CELLULAR COMMANDS ................................................................................................................................A-7
COMMON CONFIGURATION SETUP STRINGS ................................................................................................................B-1
xiii
List of Tables
Table 3-1.
Result Codes ......................................................................................................................................3-11
Table 4-1.
S-Register Summary...........................................................................................................................4-2
Table 5-1.
Fax Class 1 Commands .....................................................................................................................5-1
Table 5-2.
Fax Class 1 Calling Sequence (One Page) ....................................................................................5-7
Table 5-3.
Fax Class 1 Answering Sequence (One Page)..............................................................................5-8
Table 6-1.
Fax Class 2 Commands .....................................................................................................................6-2
Table 6-2.
T.30 Session Subparameter Codes ................................................................................................6-7
Table 6-3.
T.30 Post Page Message Codes ......................................................................................................6-8
Table 6-4.
T.30 Post Page Response Messages .............................................................................................6-8
Table 6-5.
Hang Up Status Codes .....................................................................................................................6-12
Table 6-6.
Send Two Pages, 1-D, No Errors....................................................................................................6-21
Table 6-7.
Receive Two Pages, 1-D Data, No Errors .....................................................................................6-22
Table 7-1a. 7.2 kHz Sample Rate DTE Speeds...................................................................................................7-4
Table 7-1b. 11.025 kHz Sample Rate DTE Speed..............................................................................................7-4
Table 7-2.
Shielded Codes Sent to the DTE ......................................................................................................7-5
Table 7-3.
Shielded DTE Codes ...........................................................................................................................7-7
Table 7-4.
AT Voice Commands.........................................................................................................................7-10
Table 7-5.
Device Types Supported by #VLS ...................................................................................................7-17
Table 7-6.
#VTD Tone Detection/Reporting Bit Settings ................................................................................7-22
Table 7-7.
Record a Greeting Message ............................................................................................................7-31
Table 7-8.
Playback a Greeting Message.........................................................................................................7-33
Table 7-9.
Answer Call/Play Greeting/Record Message................................................................................7-34
Table 7-10. Answer Call/Record Message/Receive Fax..................................................................................7-36
Table 7-11. Answer Call, Determine It's a Fax...................................................................................................7-38
Table 7-12. Adaptive Fax/Data/Voice....................................................................................................................7-39
Table 7-13. Originate a Call, Send Answerer a Message................................................................................7-40
List of Figures
Figure 6-1.
T.30 Session Parameter Relationships ........................................................................................6-16
xiv
883
AT Command Reference Manual
1.
1.1.
INTRODUCTION
OVERVIEW
This manual describes the AT commands for the following Rockwell modem families:
RC144ACi and RC144ATi
RC144ACL and RC144ATL
RC144ACG
RC144ACF and RC144ATF
RC144ACFL and RC144ATFL
RCV144ACi/SP
The descriptions apply to all these modems with any differences between modem product families noted. Refer to MCU
FIrmware Release notes for the exact applicable commands to modem firmware.
Voice/Audio Mode operation in business audio products require use of the Proprietary Rockwell High Speed Interface
(RHSI) included in the modem MCU firmware and use of an RHSI compatible communication software driver
(RHSICOMM.DRV) in the host computer when operating in the Microsoft Windows environment.
ATi, ATL, ATF, and ATFL models support error correction and data compression (ECC) performed by the host CPU and
communications software for Windows using the enhanced Rockwell Windows Protocol Interface (RPI or RPI+™) and
WinRPI host software module.
1.1.1.
Command Syntax
The fundamental DTE interface command syntax is described in Section 2.
1.1.2.
Command Descriptions
These commands are grouped into the following categories:
AT commands
S-Registers
Fax Class 1 commands
Fax Class 2 commands
Voice/Audio commands
Section 3
Section 4
Section 5
Section 6
Section 7
The AT commands are implemented in microcontroller (MCU) firmware for specific modem models. The support for a
command category is identified by modem model in the modem designer's guide. Additional configuration and
implementation information is available in release notes and/or readme files that accompany MCU firmware release.
1.1.3.
Call Progress and Blacklisting Parameters
The modem MCU firmware may be provided either in reconfigurable form or preconfigured form. Consult the specifi c
firmware release notes for exact configuration information.
Reconfigurable Form. The modem MCU firmware can be configured for operation in specific countries by the PCcompatible ConfigurACE II program. The call progress and blacklisting parameters described in the ConfigurACE II User's
Manual can be altered and loaded for a number of countries by this program.
Preconfigured Form. Specific MCU firmware configurations may be released that can be directly installed without requiring
the use of ConfigurACE II.
1.1.4.
ConfigurACE II
The ConfigurACE II User's Manual describes the use of ConfigurACE II and the country modifiable parameters. Consult any
readme files accompanying the ConfigurACE II program for additional or later information.
883
1-1
AT Command Reference Manual
1.2.
REFERENCE DOCUMENTATION
Order No.
Description
MD86
MD108
MD95
MD129
MD130
MD137
RC144ACi and RC144ACL Modem Data Sheet
RC144ACG Modem Data Sheet
RC144ATi and RC144ATL Modem Data Sheet
RC144ACF and RC144ATF Modem Data Sheet
RC144ACFL and RC144ATFL Modem Data Sheet
RCV144ACi/SP Modem Data Sheet
876
897
1008
1027
1055
RC144ACi and RC144ACL Modem Designer's Guide
RC144ATi and RC144ATL Modem Designer's Guide
RC144ACG Modem Designer's Guide
RC144ACFL and RC144ATFL Modem Designer's Guide
RC144ACF and RC144ATF Modem Designer's Guide
893
ConfigurACE II User's Manual
1-2
883
AT Command Reference Manual
2.
2.1.
COMMAND SYNTAX
DTE/DCE INTERCHANGE CIRCUITS
Communication between the DTE and modem is half duplex (i.e., only one entity 'talks' at a time).
2.2.
2.2.1.
COMMAND SYNTAX AND GUIDELINES
DTE Commands
The ISO 646 character set (CCITT T.50 International Alphabet 5, American Standard Code for Information Interchange) is
used for the issuance of commands and responses. Only the low-order 7 bits of each character are used for commands or
parameters; the high-order bit is ignored. Upper case characters are equivalent to lower case characters.
2.2.2.
DTE Command Lines
A command line is a string of characters sent from a DTE to the DCE while the DCE is in a command state. Command
lines have a prefix, a body, and a terminator. The prefix consists of the ASCII characters “AT” (065, 084) or “at” (097, 116).
The body is a string of commands restricted to printable ASCII characters (032 - 126). Space characters (ASCII 032) and
control characters other than carriage return <CR> (default value = ASCII 013 = 0Dh, see register S3), backspace <BS>
(default value = ASCII 008 = 08h, see register S5), and cancel <cntrl-x> (ASCII 024 = 18h) in the command string are
ignored. The default terminator is the <CR> character. Characters that precede the AT prefix are ignored.
2.3.
AT COMMAND GUIDELINES
Modem operation is controlled by generic AT commands. These AT commands may be basic AT (i.e., commands preceded
by AT, AT&, AT%, AT*, AT\, AT), AT-, or AT#), S-Register (e.g., S6=n), Fax class 1 (e.g., +FTM), Fax class 2 (e.g., +FDCS:), or
voice (e.g., #VBS) commands. The command syntax and operation guidelines governing each of these command
categories are described in subsequent sections.
2.3.1.
Basic Command Syntax
Characters within the command line are parsed as commands with associated parameter values. The basic commands
consist of single ASCII characters, or single characters preceded by a prefix character, followed by a decimal parameter
(e.g., “&D1"). Missing decimal parameters are evaluated as 0.
2.3.2.
Extended Command Syntax
The facsimile commands use extended syntax. They are preceded by the “+F” characters, and they are terminated by the
semicolon “:” character (ASCII 059) or by the <CR> that terminates the command line.
883
2-1
AT Command Reference Manual
This page is intentionally blank.
2-2
883
AT Command Reference Manual
3.
3.1.
AT COMMAND SET
AT COMMAND GUIDELINES
The basic AT commands used to control modem operation are defined in this section. These commands are summarized
in Appendix A. All these commands may not be available in a specific product depending upon supported data rates and
modes. The default values are typical of a fully configured modem supporting all data rates and options. The actual default
value is dependent upon modem firmware as defined by the firmware releas e notes.
3.1.1.
AT Commands, DTE Adaption
Under AT operation, the serial interfaced modem performs an autobaud/autoparity/autolength function on each AT header
entered. The autolength/autoparity facility can detect 7- or 8-bit characters of even, odd, or no parity with one stop bit. This is
not necessary for the parallel interfaced modem since it has direct access to the UART registers.
3.1.2.
AT Command Format
A command line is a string of characters sent from a DTE to the modem (DCE) while the modem is i n a command state. A
command line has a prefix, a body, and a terminator. Each command line (with the exception of the A/ command) must
begin with the character sequence AT and must be terminated by a carriage return. Commands entered in upper case or
lower case are accepted, but both the A and T must be of the same case, i.e., "AT" = ASCII 065, 084 or “at” = ASCII 097, 116.
The body is a string of commands restricted to printable ASCII characters (032 - 126). Space characters (ASCII 032) and
control characters other than CR (ASCII 013) and BS (ASCII 010) in the command string are ignored. The default terminator
is the ASCII <CR> character. Characters that precede the AT prefix are ignored. The command line interpretation begins
upon receipt of the carriage return character.
Characters within the command line are parsed as commands with associated parameter values. The basic commands
consist of single ASCII characters, or single characters preceded by a prefix character (e.g., “&"), followed by a decimal
parameter. Missing decimal parameters are evaluated as 0.
The modem supports the editing of command lines by recognizing a backspace character. When modem echo is enabled,
the modem responds to receipt of a backspace or delete by echoing a backspace character, a space character, and
another backspace. The hex value to be used for the backspace character is programmable through register S5. Values
equal to 0 or greater than 127, or the value which corresponds to the carriage return character, cannot be used for the
backspace character. This editing is not applicable to the AT header of a command. A command line may be aborted at any
time by entering < cntrl-x > (18h).
The AT sequence may be followed by any number of commands in sequence, except for commands such as Z, D, or A.
Commands following commands Z, D, or A on the same command line will be ignored. The maximum number of
characters on any command line is 39 (including "A" and "T"). If a syntax error is found anywhere in a command line
command, the remainder of the line will be ignored and the ERROR result code will be returned.
Most commands entered with parameters out of range will not be accepted and the ERROR response will be returned to
the DTE.
Commands will only be accepted by the modem once the previ ous command has been fully executed, which is normally
indicated by the return of an appropriate result code. Execution of commands D and A, either as a result of a direct
command or a re-execute command, will be aborted if another character is entered before completion of the handshake.
3.1.3.
Escape Code Sequence
When the modem has established a connection and has entered on-line data mode, it is possible to break into the data
transmission in order to issue further commands to the modem in an on-line com mand mode. This is achieved by the DTE
sending to the modem a sequence of three ASCII characters specified by register S2. The default character is '+'. The
maximum time allowed between receipt of the last character of the three escape character sequence from the DTE and
sending of the OK result code to the DTE is controlled by the S12 register.
883
3-1
AT Command Reference Manual
3.2.
AT COMMAND SET
The modem will respond to the commands detailed below. Parameters applicable to each command are listed with the
command description. The defaults shown for each configuration command are those used in the Rockwell factory
profile 0.
3.2.1.
AT Commands
A/ - Re-execute Command
The modem behaves as though the last command line had been re-sent by the DTE. "A/" will repeat all the commands in
the command buffer.
The principal application of this command is to place another call (using the Dial command) that failed to connect due to a
busy line, no answer, or a wrong number. This command must appear alone on a command line. This command should
not be terminated by a carriage return.
AT= x - Write to Selected S-Register
This command writes the value x to the currently selected S-Register. An S-Register can be selected by using the ATSn
command. All of the S-Registers will return the OK response if x is a number. Some registers may not be written due to
country specific PTT limitations.
Result Codes
OK
For all arguments.
AT? - Read Selected S-Register
This command reads and displays the selected S-Register. An S-Register can be selected by using the ATSn command.
Result Codes:
OK
For all arguments.
A - Answer
The modem will go off-hook and attempt to answer an incoming call if correct conditions are met. Upon successful
completion of answer handshake, the modem will go on-line in answer mode. This command may be affected by the state
of Line Current Sense, if enabled. (Most countries do not require Line Current Sense.) Operation is also dependent upon
+FCLASS command and country-specific requirements.
If +FCLASS=0 is selected, the modem will enter the connect state after exchanging carrier with the remote modem. If no
carrier is detected within a period specified in register S7, the modem hangs up. Any character entered during the connect
sequence will abort the connection attempt.
If +FCLASS=1 or 2 is selected, the modem will go off-hook in V.21 answer mode. It will generate the V.21 2100 Hz answer
tone for 3 ± 0.5 seconds and, following a delay of 70 ms, will proceed as if the +FTH=3 command were issued. At any stage
up to (but excluding) the +FTH=3 command state, any character will abort the communication. (See the description of the
+FTH command for details.)
Bn - CCITT or Bell
When the modem is configured to allow either option, the modem will select Bell or CCITT modulation for a line speed
connection of 300 or 1200 bps according to the parameter supplied. Any other line speed will use a CCITT modulation
standard. The parameter value, if valid, is written to S27 bit 6. (Also, see ATFn command.)
B0
Selects CCITT operation at 300 or 1200 bps during Call Establishment and a subsequent
connection. (Default for W-class models.)
B1
Selects BELL operation at 300 or 1200 bps during Call Establishment and a subsequent
connection. (Default for US models.)
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
3-2
883
AT Command Reference Manual
Cn - Carrier Control
This command is included for compatibility only, and has no effect other than returning a result code. The only valid
parameter is 1.
Result Codes:
OK
ERROR
n = 1.
Otherwise.
Dn - Dial
This command directs the modem to go on-line, dial according to the string entered and attempt to establish a connection.
If no dial string is supplied, the modem will go on-line and attempt the handshake in originate mode. In W-class models,
the action of going off-hook is affected by the status of the Line Current Sense input, if line current sensing is enabled, and
by the blacklist and delayed list. NOTE: If the ATD command is issued before the S1 register has cleared, the modem will
respond with the NO CARRIER result code.
If +FCLASS=0 is selected, the modem will behave as a data modem and will attempt to connect to another data modem.
The modem will have up to the period of time specified by register S6 or S7 to wait for carrier and complete the handshake.
If this time expires before the modem can complete the hands hake, the modem will go on-hook with the NO CARRIER
response. This command will be aborted in progress upon receipt of any DTE character before completion of the
handshake.
If +FCLASS=1 or 2 is selected, the modem will behave as a facsimile modem and attem pt to connect to a facsimile
machine (or modem) by entering the HDLC V.21 channel 2 receive state (as if +FRH=3 had been issued). This command
will be aborted upon receipt of any DTE character if the modem has not finished dialing. In this case, the modem will go onhook and return to command mode after displaying the NO CARRIER message. If the modem has finished dialing, it
proceeds as if the +FRH=3 command has been issued. (Refer to the +FRH command to determine how the modem
behaves following this stage.)
Dial Modifiers. The valid dial string parameters are described below. Punctuation characters may be used for clarity, with
parentheses, hyphen, and spaces being ignored.
883
0-9
DTMF digits 0 to 9.
*
The 'star' digit (tone dialing only).
#
The 'gate' digit (tone dialing only).
A-D
DTMF digits A, B, C, and D. Some countries may prohibit sending of these digits during dialing.
J
Perform MNP 10 link negotiation at 1200 bps (for this call only). (See *H.)
K
Enable power level adjustment during MNP 10 link negotiation (for this call only). (See )Mn.)
L
Re-dial last number: the modem will re-dial the last valid telephone number. The L must be
immediately after the D with all the following characters ignored).
P
Select pulse dialing: pulse dial the numbers that follow until a "T" is encountered. Affects current
and subsequent dialing. Some countries prevent changing dialing modes after the first digit is
dialed.
T
Select tone dialing: tone dial the numbers that follow until a "P" is encountered. Affects current and
subsequent dialing. Some countries prevent changing dialing modes after the first digit is dialed.
R
This command will be accepted, but not acted on.
S=n
Dial the number stored in the directory (n = 0 to 3). (See &Z.)
!
Flash: the modem will go on-hook for a time defined by the value of S29. Country requirements may
limit the time imposed.
W
Wait for dial tone: the modem will wait for dial tone before dialing the digits following "W". If dial tone
is not detected within the time specified by S7 (US) or S6 (W-class), the modem will abort the rest
of the sequence, return on-hook, and generate an error message.
3-3
AT Command Reference Manual
@
Wait for silence: the modem will wait for at least 5 seconds of silence in the call progress frequency
band before continuing with the next dial string parameter. If the modem does not detect these 5
seconds of silence before the expiration of the call abort timer (S7), the modem will terminate the
call attempt with a NO ANSWER message. If busy detection is enabled, the modem may terminate
the call with the BUSY result code. If answer tone arrives during execution of this parameter, the
modem handshakes.
&
Wait for credit card dialing tone before continuing with the dial string. If the tone is not detected
within the time specified by S7 (US models) or S6 (W-class models), the modem will abort the rest
of the sequence, return on-hook, and generate an error message.
,
Dial pause: the modem will pause for a time specified by S8 before dialing the digits following ",".
;
Return to command state. Added to the end of a dial string, this causes the modem to return to the
command state after it processes the portion of the dial string preceding the ";". This allows the
user to issue additional AT commands while remaining off-hook. The additional AT commands
may be placed in the original command line following the ";" and/or may be entered on subsequent
command lines. The modem will enter call progress only after an additional dial command is
issued without the ";" terminator. Use "H" to abort the dial in progress, and go back on-hook.
^
Toggles calling tone enable/disable: applicable to current dial attempt only.
()
Ignored: may be used to format the dial string.
-
Ignored: may be used to format the dial string.
<space>
Ignored: may be used to format the dial string.
<i>
Invalid character: will be ignored.
>
If enabled by country specific parameter, the modem will generate a grounding pulse on the
EARTH relay output.
En - Command Echo
The modem enables or disables the echo of characters to the DTE according to the parameter supplied. The parameter
value, if valid, is written to S14 bit 1.
E0
Disables command echo.
E1
Enables command echo. (Default.)
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
3-4
883
AT Command Reference Manual
Fn - Select Line Modulation
This command selects the line modulation according to the parameter supplied. The line modulation is fixed unless
Automode is selected. This command interacts with the S37 and the N command. The parameter value, if valid, is written to
S37 bits 0-4. To select line modulation, it is recommended that either the F command, or a combination of the S37 and the
N command, be used, but not both.
F0
Selects auto-detect mode. Sets N1 and sets S31 bit 1. In this mode, the modem configures for
automode operation. All connect speeds supported by the modem are p ossible according to the
remote modem's preference. The contents of S37 are ignored as is the sensed DTE speed.
F1
Selects V.21 or Bell 103 according to the B setting as the only acceptable line speed resulting in
a subsequent connection. Sets N0, sets S37 to 1, and clears S31 bit 1. This command is
equivalent to the command string: ATN0S37=1.
F2
Not supported.
F3
Selects V.23 as the only acceptable line modulation for a subsequent connection. Originator is at
75 bps and answerer is at 1200 bps. Sets N0, sets S37 to 7, and clears S31 bit 1. This
command is equivalent to the command string: ATN0S37=7.
F4
Selects V.22 1200 or Bell 212A according to the B command setting as the only acceptable line
speed for a subsequent connection. Sets N0, sets S37 to 5, and clears S31 bit 1. This command
is equivalent to the command string: ATN0S37=5.
F5
Selects V.22 bis as the only acceptable line modulation for a subsequent connection. Sets N0,
sets S37 to 6, and clears S31 bit 1. This command is equivalent to the command s tring:
ATN0S37=6.
F6
Select V.32 bis 4800 or V.32 4800 as the only acceptable line modulation for a subsequent
connection. Sets N0, sets S37 to 8, and clears S31 bit 1. This command is equivalent to the
command string: ATN0S37=8.
F7
Selects V.32 bis 7200 as the only acceptable line modulation for a subsequent connection. Sets
N0, sets S37 to 12, and clears S31 bit 1. This command is equivalent to the command string:
ATN0S37=12.
This setting also allows connection at the Rockwell proprietary 7200 V.32 speed, e.g., with a
RC9696/12 based modem.
F8
Selects V.32 bis 9600 or V.32 9600 as the only acceptable line modulations for a subsequent
connection. Sets N0, sets S37 to 9, and clears S31 bit 1. This command is equivalent to the
command string: ATN0S37=9.
F9
Selects V.32 bis 12000 as the only acceptable line modulation for a subsequent connection.
Sets N0, sets S37 to 10, and clears S31 bit 1. This command is equivalent to the command
string: ATN0S37=10.
This setting also allows connection at the Rockwell proprietary 12000 V.32 speed, e.g., with a
RC9696/12 based modem.
F10
883
Selects V.32 bis 14400 as the only acceptable line modulation for a subsequent connection.
Sets N0, sets S37 to 11, and clears S31 bit 1. This command is equivalent to the command
string: ATN0S37=11.
3-5
AT Command Reference Manual
Hn - Disconnect (Hang-Up)
This command initiates a hang up sequence.
This command may not be available for some countries due to PTT restrictions.
H0
The modem will release the line if the modem is currently on-line, and will terminate any test
(AT&T) that is in progress. Country specific, modulation specific, and error correction protocol
specific (S38) processing is handled outside of the H0 command.
H1
If on-hook, the modem will go off-hook and enter command mode. For US models, the modem
will remain off-hook. For W-class models, the modem will return on-hook after a period of time
determined by S7.
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
In - Identification
The modem reports to the DTE the requested result according to the command parameter.
I0
Reports product code. Example: 14400
I1
Calculates the ROM checksum and reports the least significant byte of the checksum in decimal
(see firmware release notes). Reports 255 if the prestored checksum value is FFh.
I2
Calculates the ROM checksum and compares it with the prestored checksum. Reports "OK" if
the calculated checksum equals the prestored checksum or if the prestored checksum value is
FFh; otherwise reports “ERROR”.
I3
Reports the firmware version (F), basic model (ACX), application code (A), and interface type
code (I) in the form VF.FFF-ACX_AI. The application codes are: D = Desktop, L = Low Power
(PCMCIA). The interface type codes are: S = Serial, P = Parallel. Example: V1.200-ACL_DS
I4
Reports OEM defined identifier string in either Hayes-compatible binary format (default) or ASCII
format (selectable by ConfigurACE). Example: RC144ACi (ASCII)
I5
Reports Country Code parameter. Example: 022
I6
Reports modem data pump model and internal code revision. Example: RC144DPL Rev 05BA
Result Codes:
OK
ERROR
n = 0 to 7.
Otherwise.
Ln - Speaker Volume
The modem sets the speaker volume control according to the parameter supplied. The parameter value, if valid, is written
to S22 bits 0 and 1.
L0
Low volume.
L1
Low volume. (Default.)
L2
Medium volume.
L3
High volume.
Result Codes:
OK
ERROR
n = 0 to 3.
Otherwise.
3-6
883
AT Command Reference Manual
Mn - Speaker Control
This command selects when the speaker will be on or off. The parameter value, if valid, is written to S22 bits 2 and 3.
M0
Speaker is always off.
M1
Speaker is on during call establishment, but off when receiving carrier. (Default.)
M2
Speaker is always on.
M3
Speaker is off when receiving carrier and during dialing, but on during answering.
Result Codes:
OK
ERROR
n = 0 to 3.
Otherwise.
Nn - Automode Enable
This command enables or disables automode detection. The parameter value, if valid, is written to S31 bit 1.
N0
Automode detection is disabled. A subsequent handshake will be conducted according to the
contents of S37 or, if S37 is zero, according to the most recently sensed DTE speed.
N1
Automode detection is enabled. A subsequent handshake will be conducted according to the
automode algorithm supported by the modem. This command is equivalent to F0. (Default.)
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
On - Return to On-Line Data Mode
This command determines how the modem will enter the on-line data mode. If the modem is in the on-line command
mode, the enters the on-line data mode with or without a retrain. If the modem is in the off-line command mode (no
connection), ERROR is reported.
O0
Enters on-line data mode without a retrain. Handling is determined by the Call Establishment
task. Generally, if a connection exists, this command connects the DTE back to the remote
modem after an escape (+++).
O1
Enters on-line data mode with a retrain before returning to on-line data mode.
Result Codes:
OK
ERROR
883
n = 0 or 1 and a connection exists.
Otherwise or if not connected.
3-7
AT Command Reference Manual
P - Set Pulse Dial Default
This command forces pulse dialing until the next T dial modifier or T command is received. Sets S14 bit 5.
As soon as a dial command is executed which explicitly specifies the dialing mode for that particular call (e.g., ATDT...), this
command is overridden so that all future dialing will be tone dialed. (See T command.)
This command may not be permitted in some countries.
Result Code:
OK
Qn - Quiet Results Codes Control
The command enables or disables the sending of result codes to the DTE according to the parameter supplied. The
parameter value, if valid, is written to S14 bit 2.
Q0
Enables result codes to the DTE. (Default.)
Q1
Disables result codes to the DTE.
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
Sn - Read/Write S-Register
The modem selects an S-Register, performs an S-Register read or write function, or reports the value of an S-Register.
n
Establishes S-Register n as the last register accessed.
n=v
Sets S-Register n to the value v.
n?
Reports the value of S-Register n.
The parameter n can be omitted, in which case the last S-Register accessed will be assumed. The S can be omitted for
AT= and AT?, in which case the last S-Register accessed will be assumed.
For example:
ATS7 establishes S7 as the last accessed register.
AT=40 sets the contents of the last register accessed to 40.
ATS=20 sets the contents of the last register accessed to 20.
If the number "n" is beyond the range of the S-Registers available, the modem will return the ERROR message. The value
"v" is "MOD"ed with 256. If the result is outside the range permitted for a given S-Register the values will s till be stored, but
functionally the lower and higher limits will be observed. Input and output are always in decimal format. Note that some SRegisters are read-only.
In some cases, writing to the S-Register will appear to be accepted but the value will not actually be written.
Due to country restrictions, some commands will be accepted, but the value may be limited and replaced by a maximum or
minimum value.
Minimum, maximum, and default values for S-Registers may be altered with ConfigurACE.
3-8
883
AT Command Reference Manual
T - Set Tone Dial Default
This command forces DTMF dialing until the next P dial modifier or P command is received. The modem will set an SRegister bit to indicate that all subsequent dialing should be conducted in tone mode. Note that the DP command will
override this command. Clears S14 bit 5.
This command may not be permitted in some countries. (See P.)
Result Code:
OK
Vn - Result Code Form
This command selects the sending of short-form or long-form result codes to the DTE. The parameter, if valid, is written to
S14 bit 3.
V0
Enables short-form (terse) result codes. Line feed is not issued before a short-form result code.
V1
Enables long-form (verbose) result codes. (Default.)
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
Wn - Connect Message Control
This command controls the format of CONNECT messages. The parameter value, if valid, is written to S31 bits 2 and 3.
Note that the Wn command can be overridden by register S95 bits (see S95 description).
W0
Upon connection, the modem reports only the DTE speed (e.g., CONNECT 19200). Subsequent
responses are disabled. (Default.)
W1
Upon connection, the modem reports the line speed, the error correction protocol, and the DTE
speed, respectively. Subsequent responses are disabled.
W2
Upon connection, the modem reports the D CE speed (e.g., CONNECT 14400). Subsequent
responses are disabled.
Result Codes:
OK
ERROR
883
n = 0, 1, or 2.
Otherwise.
3-9
AT Command Reference Manual
Xn - Extended Result Codes:
This command selects which subset of the result messages will be used by the modem to inform the DTE of the results of
commands.
Blind dialing is enabled or disabled by country parameters. If the user wishes to enforce dial tone detection, a "W" can be
placed in the dial string (see D command). Note that the information below is based upon the default implementati on of the
X results table. Table 3-1 indicates the messages which are enabled for each X value.
If the modem is in facsimile mode (+FCLASS=1 or 2), the only message sent to indicate a connection is CONNECT without
a speed indication.
X0
Disables monitoring of busy tones unless forced otherwise by country requirements; send only
OK, CONNECT, RING, NO CARRIER, ERROR, and NO ANSWER result codes. Blind dialing is
enabled/disabled by country parameters. If busy tone detection is enforced and busy tone is
detected, NO CARRIER will be reported. If dial tone detection is enforced or selected and dial
tone is not detected, NO CARRIER will be reported instead of NO DIAL TONE. The value 000b is
written to S22 bits 6, 5, and 4, respectively.
X1
Disables monitoring of busy tones unless forced otherwise by country requirements; send only
OK, CONNECT, RING, NO CARRIER, ERROR, NO ANSWER, and CONNECT XXXX (XXXX = rate).
Blind dialing enabled/disabled by country parameters. If busy tone detection is enforced and
busy tone is detected, NO CARRIER will be reported instead of BUSY. If dial tone detection is
enforced or selected and dial tone is not detected, NO CARRIER will be reported instead of NO
DIAL TONE. The value 100b is written to S22 bits 6, 5, and 4, respectively.
X2
Dis ables monitoring of busy tones unless forced otherwise by country requirements; send only
OK, CONNECT, RING, NO CARRIER, ERROR, NO DIALTONE, NO ANSWER, and CONNECT
XXXX. If busy tone detection is enforced and busy tone is detected, NO CARRIER will be reported
instead of BUSY. If dial tone detection is enforced or selected and dial tone is not detected, NO
DIAL TONE will be reported instead of NO CARRIER. The value 101b is written to S22 bits 6, 5,
and 4, respectively.
X3
Enables monitoring of busy tones; send only OK, CONNECT, RING, NO CARRIER, ERROR, NO
ANSWER, and CONNECT XXXX. Blind dialing is enabled/disabled by country parameters. If dial
tone detection is enforced and dial tone is not detected, NO CARRIER will be reported. The value
110b is written to S22 bits 6, 5, and 4, respectively.
X4
Enables monitoring of busy tones; send all messages. The value 111b is written to S22 bits 6, 5,
and 4, respectively. (Default.)
Result Codes:
OK
ERROR
n = 0 to 4.
Otherwise.
3-10
883
AT Command Reference Manual
Table 3-1.
Short Form
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
22
23
24
32
33
35
40
44
45
46
47
48
49
50
51
52
66
67
69
76
77
883
Result Codes
Long Form
0
x
x
x
x
x
1
3
3
x
1
1
1
1
1
1
1
1
1
1
1
1
1
4
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
OK
CONNECT
RING
NO CARRIER
ERROR
CONNECT 1200
NO DIALTONE
BUSY
NO ANSWER
CONNECT 0600
CONNECT 2400
CONNECT 4800
CONNECT 9600
CONNECT 7200
CONNECT 12000
CONNECT 14400
CONNECT 19200
CONNECT 38400
CONNECT 57600
CONNECT 115200
CONNECT 75TX/1200RX
CONNECT 1200TX/75RX
DELAYED
BLACKLISTED
FAX
DATA
CARRIER 300
CARRIER 1200/75
CARRIER 75/1200
CARRIER 1200
CARRIER 2400
CARRIER 4800
CARRIER 7200
CARRIER 9600
CARRIER 12000
CARRIER 14400
COMPRESSION: CLASS 5
COMPRESSION: V.42 bis
COMPRESSION: NONE
PROTOCOL: NONE
PROTOCOL: LAPM
3-11
n Value in ATXn Command
1
2
3
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
3
x
x
3
3
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
4
4
4
4
4
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
AT Command Reference Manual
Table 3-1.
Short Form
Result Codes (Cont’d)
Long Form
n Value in ATXn Command
0
1
2
3
4
80
PROTOCOL: ALT
x
x
x
x
x
81
PROTOCOL: ALT-CELLULAR
x
x
x
x
x
+F4
+FCERROR
x
x
x
x
x
Note: An 'x' in a column indicates that the message (either the long form if verbose, or the
value only for short form) will be generated when that particular value of 'n' (shown at the top
of the column) has been selected by the use of ATXn. If the column is blank, then no
message will be generated for that x option. A numeral indicates which less explicit
message (verbose or short form) will be output for that X option. (Also, see Section 3.3).
Yn - Long Space Disconnect
This command enables/disables the generation and response to long space disconnect. The parameter value, if valid, is
written to S21 bit 7.
Y0
Disables long space disconnect. (default.)
Y1
Enables long space disconnect. In non-error correction mode, the modem will send a long
space of four seconds prior to going on-hook. In error correction mode, the modem will respond
to the receipt of a long space (i.e., a break signal greater than 1.6 seconds) by going on-hook.
Res ult Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
Zn - Soft Reset and Restore Profile
The modem performs a soft reset and restores (recalls) the configuration profile according to the parameter supplied. If no
parameter is specified, zero is assumed.
Z0
Soft reset and restore stored profile 0.
Z1
Soft reset and restore stored profile 1.
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
3-12
883
AT Command Reference Manual
3.2.2.
AT& Commands
&Cn - RLSD (DCD) Option
The modem controls the RLSD output in accordance with the parameter supplied. The parameter value, if valid, is written to
S21 bit 5.
&C0
RLSD remains ON at all times.
&C1
RLSD follows the state of the carrier. (Default.)
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
&Dn - DTR Option
This command interprets the ON to OFF transition of the DTR signal from the DTE in accordance with the parameter
supplied. The parameter value, if valid, is written to S21 bits 3 and 4. Also, see S25.
&D0 -
&D1
DTR drop is interpreted according to the current &Qn setting as follows:
&Q0, &Q5, &Q6
DTR is ignored (assum ed ON). Allows operation with DTEs which do
not provide DTR.
&Q1, &Q4
DTR drop causes the modem to hang up. Auto -answer is not affected.
&Q2, &Q3
DTR drop causes the modem to hang up. Auto -answer is inhibited.
DTR drop is interpreted according to the current &Qn setting as follows:
&Q0, &Q1, &Q4, &Q5, &Q6
DTR drop is interpreted by the modem as if the asynchronous
escape sequence had been entered. The modem returns to
asynchronous command state without disconnecting.
&Q2, &Q3
&D2
DTR drop is interpreted according to the current &Qn setting as follows:
&Q0 through &Q6
&D3
DTR drop causes the modem to hang up. Auto-answer is inhibited.
DTR drop causes the modem to hang up. Auto -answer is inhibited.
(Default.)
DTR drop is interpreted according to the current &Qn setting as follows:
&Q0, &Q1, &Q4, &Q5, &Q6
DTR drop causes the modem to perform a soft reset as if the
Z command were received. The &Y setting determines which profile is
loaded.
&Q2, &Q3
DTR drop causes the modem to hang up. Auto -answer is inhibite d.
If &Q5, &Q6, +FCLASS=1 or +FCLASS=2 is in effect, the action taken is the same as for &Q0.
&Fn - Restore Factory Configuration (Profile)
The modem loads the factory default configuration (profile). The factory defaults are identified for each command and in the
S-Register descriptions. A configuration (profile) consists of a subset of S-Registers.
&F0
Restore factory configuration 0.
&F1
Restore factory configuration 1.
Result Codes:
OK
ERROR
883
If the modem is connected.
3-13
AT Command Reference Manual
&Gn - Select Guard Tone
The modem generates the guard tone selected by this command according to the parameter supplied (DPSK modulation
modes only). The parameter value, if valid, is written to S23 bits 6 and 7.
&G0
Disables guard tone. (Default for US models.)
&G1
Disables guard tone.
&G2
Selects 1800 Hz guard tone. (Default for W-class models.)
This command may not be permitted in some countries.
Result Codes:
OK
ERROR
n = 0 to 2.
Otherwise.
&Jn - Telephone Jack Control
This command is only included for compatibility and performs no function except to load the S-Register. The parameter
value, if valid, is written S21 bit 1.
&J0
&J0 command. (Default.)
&J1
&J1 command.
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
&Kn - Flow Control
This command defines the DTE/DCE (terminal/modem) flow control mechanism. The parameter value, if valid, is written to
S39 bits 0, 1, and 2.
&K0
Disables flow control.
&K3
Enables RTS/CTS flow control. (Default for data modem modes.)
&K4
Enables XON/XOFF flow control.
&K5
Enables transparent XON/XOFF flow control.
&K6
Enables both RTS/CTS and XON/XOFF flow control. (Default for fax modem and voice modes.)
Result Codes:
OK
ERROR
n = 0, 3, 4, 5, or 6.
Otherwise.
&Ln - Leased Line Operation
This command requests leased line or dial-up operation. This command is provided for compatibility only; no mode
change is performed, dial-up operation continues. The OK response is returned for a valid parameter, but no other action is
performed. The parameter value, if valid, is written to S27 bit 2.
&L0
Requests dial-up operation. Dial-up operation continues.
Result Codes:
OK
ERROR
n = 0.
Otherwise.
3-14
883
AT Command Reference Manual
&Mn - Asynchronous/Synchronous Mode Selection
This command determines the DTR operating mode. The modem treats the &M command as a subset of the &Q
command.
&M0
Selects direct asynchronous operation. Note that the command sequence &M0 \N0 selects
normal buffered mode, but the command sequence \N0&M0 selects direct mode. This is
because the \N0 command is analogous to the &Q6 command. The value 000b is written to S27
bits 3, 1, and 0, respectively. (See &Q).
&M1
Selects synchronous connect mode with async off-line command mode. The value 001b is
written to S27 bits 3, 1, and 0, respectively. (Serial interface operation only.)
&M2
Selects synchronous connect mode with async off-line com mand mode. Same as &M1 except
that &M2 enables DTR dialing of directory slot 0. The modem will disconnect if DTR is OFF for
more than the period in S25 (in units of hundredths of a second): the data connection will be
synchronous. The value 010b is written to S27 bits 3, 1, and 0, respectively. (Serial interface
operation only.)
&M3
Selects synchronous connect mode. This mode allows DTR to act as a talk/data switch. The call
is manually initiated while DTR is inactive. When DTR becomes active, the handshake proceeds
in originate or answer mode according to S14 bit 7. The value 011b is written to S27 bits 3, 1, and
0, respectively. (Serial interface operation only.)
Result Codes:
OK
ERROR
n = 0 to 3.
Otherwise.
&Pn - Select Pulse Dial Make/Break Ratio
This command determines the make/break ratio used during pulse dialing. It is only effective if the appropriate bit to enable
this command is set through the ConfigurACE program. If enabled, it will override the make/break ratios in the OEM
parameters in ConfigurACE. The default is country-dependent. The parameter value, if valid, is written to S28 bits 3 and 4.
&P0
Selects 39%-61% make/break ratio at 10 pulses per second. (Default.)
&P1
Selects 33%-67% make/break ratio at 10 pulses per second.
&P2
Selects 39%-61% make/break ratio at 20 pulses per second.
&P3
Selects 33%-67% make/break ratio at 20 pulses per second.
Result Codes:
OK
ERROR
883
n = 0 to 3.
Otherwise.
3-15
AT Command Reference Manual
&Qn - Sync/Async Mode
This command is an extension of the &M command and is used to control the connecti on modes permitted. It is used in
conjunction with S36 and S48. (Also, see \N.)
NOTE: When the &Q0 to &Q4 command is issued to select the mode, the subsequent connect message will report the DCE
speed regardless of the W command and S95 settings.
&Q0
Selects direct asynchronous operation. The value 000b is written to S27 bits 3, 1, and 0,
respectively. See &M0.
&Q1
Selects synchronous connect mode with async off-line command mode. The value 001b is
written to S27 bits 3, 1, and 0, respectively. See &M1. (Serial interface operation only.)
&Q2
Selects synchronous connect mode with async off-line command mode and enables DTR
dialing of directory 0. The value 010b is written to S27 bits 3, 1, and 0, respectively. See &M2.
(Serial interface operation only.)
&Q3
Selects synchronous connect mode with async off-line command mode and enables DTR to act
as Talk/Data switch. The value 011b is written to S27 bits 3, 1, and 0, respectively. See &M3.
(Serial interface operation only.)
&Q4
Selects AutoSync operation. The value 100b is written to S27 bits 3, 1, and 0, respectively.
AutoSync operation, when used in conjunction with the Hayes Synchronous Interface (HSI)
capability in the DTE, provides synchronous communication capability from an asynchronous
terminal.
Starting AutoSync. Set registers S19, S20, and S25 to the desired values before selecting
AutoSync operation with &Q4. After the CONNECT message is issued, the modem waits the
period of time specified by S25 before examining DTR. If DTR is on, the modem enters the
synchronous operating state; if DTR is off, the modem terminates the line connection and returns
to the asynchronous command state.
Stopping AutoSync. AutoSync operation is stopped upon loss of carrier or the on-to-off transition
of DTR. Loss of carrier will cause the modem to return to the asynchronous command state. An
on-to-off transition of DTR will cause the modem to return to the asynchronous command state
and either not terminate the line connection (&D1 active) or terminate the line connection (any
other &Dn command active).
&Q5
The modem will try to negotiate an error-corrected link. The modem can be configured using S36
to determine whether a failure will result in the modem returning on-hook or will result in fallback
to an asynchronous connection. The value 101b is written to S27 bits 3, 1, and 0, respectively.
(Default.)
&Q6
Selects asynchronous operation in normal mode (speed buffering). The value 110b is written to
S27 bits 3, 1, and 0, respectively.
Result Codes:
OK
ERROR
n = 0 to 6.
Otherwise.
3-16
883
AT Command Reference Manual
&Rn - RTS/CTS Option
This selects how the modem controls CTS. CTS operation is modified if hardware flow control is selected (see &K
command). The parameter value, if valid, is written to S21 bit 2.
&R0
In sync mode, CTS tracks the state of RTS; the RTS-to-CTS delay is defined by S26. In async
mode, CTS acts according to V.25 bis handshake.
&R1
In sync mode, CTS is always ON (RTS transitions are ignored). In async mode, CTS will only
drop if required by flow control. (Default.)
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
&Sn - DSR Override
This command selects how the modem will control DSR. The parameter value, if valid, is written to S21 bit 6.
&S0
DSR will remain ON at all times. (Default.)
&S1
DSR will become active after answer tone has been detected and inactive after the carrier has
been lost.
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
&Tn - Test and Diagnostics
The modem will perform selected test and diagnostic functions according to the parameter supplied. A test can be run only
when in an asynchronous operation in non-error-correction mode (normal or direct mode). To terminate a test in progress,
the escape sequence must be entered first, except for parameters 7 and 8 (see Section 3.1.3). If S18 is non-zero, a test will
terminate automatically after the time specified by S18 and display the OK message.
883
&T0
Terminates test in progress. Clears S16.
&T1
Initiates local analog loopback, V.54 Loop 3. Sets S16 bit 0. If a connection exists when this
command is issued, the modem hangs up. The CONNECT XXXX message is displayed upon
the start of the test.
&T2
Returns ERROR.
&T3
Initiates local digital loopback, V.54 Loop 2. Sets S16 bit 2. If no connection exists, ERROR is
returned. Sets S16 bit 4 when the test is in progress.
&T4
Enables digita l loopback acknowledgment for remote request, i.e., an RDL request from a
remote modem is allowed. Sets S23 bit 0. (Default.)
&T5
Disables digital loopback acknowledgment for remote request, i.e., an RDL request from a
remote modem is denied. Clears S23 bit 0.
&T6
Requests a remote digital loopback (RDL), V.54 Loop 2, without self test. If no connection exists,
ERROR is returned. Sets S16 bit 4 when the test is in progress. The CONNECT XXXX message
is displayed upon the start of the test.
&T7
Requests a rem ote digital loopback (RDL),V.54 Loop 2, with self test. (In self test, a test pattern
is looped back and checked by the modem.) If no connection exists, ERROR is returned. When
the test is terminated either via expiration of S18, or via the &T0 or H command, the number of
detected errors is reported to the DTE. Sets S16 bit 5 when the test is in progress.
&T8
Initiates local analog loopback, V.54 Loop 3, with self test. (In self test, a test pattern is looped
back and checked by the modem.) If a connection exists, the modem hangs up before the test is
initiated. When the test is terminated either via expiration of S18, or via the &T0 or H command,
the number of detected errors is reported to the DTE. Sets S16 bit 6 when the test is in progress.
This command may not be available in some countries due to PTT restrictions.
3-17
AT Command Reference Manual
&V - Display Current Configuration and Stored Profiles
Reports the current (active) configuration, the stored (user) profiles, and the first four stored telephone numbers. The stored
profiles and telephone numbers are not displayed if the NVRAM is not installed or is not operational as detected by the
NVRAM test during reset processing.
Result Code:
OK
Example:
AT&V
ACTIVE PROFILE:
B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &J0 &K3 &Q5 &R1 &S0 &T4 &X0 &Y0
S00:002 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:030 S08:002 S09:006
S10:014 S11:255 S12:050 S18:000 S25:005 S26:001 S36:007 S37:000 S38:020 S46:138
S48:007 S95:000
STORED PROFILE 0:
B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &J0 &K3 &Q5 &R1 &S0 &T4 &X0
S00:002 S02:043 S06:002 S07:030 S08:002 S09:006 S10:014 S11:095 S12:050 S18:000
S36:007 S37:000 S40:105 S41:003 S46:138 S95:000
STORED PROFILE 1:
B0 E1 L1 M1 N1 QO T V1 W0 X4 Y0 &C0 &D0 &G2 &J0 &K3 &Q5 &R1 &S0 &T4 &X0
S00:002 S02:043 S06:002 S07:030 S08:002 S09:006 S10:014 S11:095 S12:050 S18:000
S36:007 S37:000 S40:105 S41:003 S46:138 S95:000
TELEPHONE NUMBERS:
0 =
2 =
1 =
3 =
OK
&Wn - Store Current Configuration
Saves the current (active) configuration (profile), including S-Registers, in one of the two user profiles in NVRAM as denoted
by the parameter value. This command will yield an ERROR message if the NVRAM is not installed or is not operational as
detected by the NVRAM test.
The current configuration is comprised of a list of storable parameters illustrated in the &V command. These settings are
restored to the active configuration upon receiving an Zn command or at power up (see &Yn command).
&W0
Store the current configuration as profile 0.
&W1
Store the current configuration as profile 1.
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
3-18
883
AT Command Reference Manual
&Xn - Select Synchronous Clock Source
Selects the source of the transmit clock for the synchronous mode of operation. The parameter value, if valid, is written to
S27 bits 4 and 5.
In asynchronous mode, the transmit and receive clocks are turned OFF. In synchronous mode, the clocks are turned ON
with the frequency of 1200 Hz or faster corresponding to the speed that is selected for modem operation.
&X0
Selects internal timing. The modem g enerates the transmit clock signal and applies it to the
TXCLK output at the serial interface.
&X1
Selects external timing. The local DTE sources the transmit clock signal on the XTCLK input of
the serial interface. The modem applies this clock to the TXCLK output at the serial interface.
&X2
Selects slave receive timing. The modem derives the transmit clock signal from the incoming
carrier and applies it to the TXCLK output at the serial interface.
Result Codes:
OK
ERROR
n = 0 to 2.
Otherwise.
&Yn - Designate a Default Reset Profile
Selects which user profile will be used after a hard reset.
&Y0
The modem will use profile 0.
&Y1
The modem will use profile 1.
Result Codes:
OK
ERROR
n = 0 to 1.
If n > 1, or if NVRAM is not installed or is not operational.
&Zn=x - Store Telephone Number
The modem can store up to four telephone numbers and each telephone number dial string can contain up to 35 digits.
&Zn=x
n = 0 to 3 and x = dial string. (Requires 256-byte NVRAM.)
Result Codes:
OK
ERROR
883
For n = 3, and x = 35 digits.
If n > 3, x > 35 digits, or if NVRAM is not installed or is not operational.
3-19
AT Command Reference Manual
3.2.3.
AT% Commands
%En - Enable/Disable Line Quality Monitor and Auto-Retrain or Fallback/Fall Forward
Controls whether or not the modem will automatically monitor the line quality and request a retrain (%E1) or fall back when
line quality is insufficient or fall forward when line quality is sufficient (%E2). The parameter value, if valid, is written to S41
bits 2 and 6.
If enabled, the modem attempts to retrain for a maximum of 30 seconds.
%E0
Disable line quality monitor and auto -retrain.
%E1
Enable line quality monitor and auto-retrain.
%E2
Enable line quality monitor and fallback/fall forward. (Default.)
Result Codes:
OK
ERROR
n = 0, 1, or 2.
Otherwise.
Fallback/Fall Forward. When %E2 is active, the modem monitors the line quality (EQM). When line quality is insufficient, the
modem will initiate a rate renegotiation to a lower speed within the V.32 bis/V.32 modulation speeds. The modem will keep
falling back if necessary until the speed reaches 4800 bps. Below this rate, the modem will only do retrains if EQM
thresholds are exceeded. If the EQM is sufficient for at least one minute, the modem will initiate a rate renegotiation to a
higher speed within the V.32/V.32 bis modulation speeds. The rate renegotiations will be done without a retrain if a V.32 bis
connection is established.
Speeds attempted during fallback/fall forward are those shown to be available in the rate sequences exchanged d uring the
initial connection. Fallback/fall forward is available in error correction and normal modes, but not in direct mode or
synchronous mode with external clocks.
%L - Line Signal Level
Returns a value which indicates the received signal level. The value returned is a direct indication (DAA dependent) of the
receive level at the MDP, not at the telephone line connector. For example, 009 = -9 dBm, 043 = -43 dBm, and so on.
Result Codes:
OK
%Q - Line Signal Quality
Reports the line signal quality (DAA dependent). Returns the higher order byte of the EQM value. Based on the EQM value,
retrain or fallback/fall forward may be initiated if enabled by %E1 or %E2.
Example:
AT%Q
015
Result Codes:
OK
ERROR
If connected.
If not connected, or connected in 300 bps, V.23, or fax modes.
3-20
883
AT Command Reference Manual
%T - PTT Testing Utilities
Facilitates PTT testing of signal levels by providing continuous signals regardless of whether the modem is connected or
not. The signal transmitted is in accordance with the parameter provided.
This is a range of commands that allow the user to initiate a series of signals that are necessary for PTT approval. The
signals emitted include answer tone, modulation, carriers, and other pertinent signals. A test is initiated upon receipt of an
%TTn (the second T is a password and n is a test number), and the test is aborted when any keyboard character is entered.
The modem will continuously transmit the tone or carrier according to the parameter supplied.
%TT00-%TT09
%TT0A
%TT0B
%TT0C
%TT0D
%TT0E
%TT0F
%TT10
%TT11
%TT12
%TT13
%TT15
%TT16
%TT17
%TT18
%TT19
%TT1A
%TT1B
%TT1C
%TT20
%TT21
%TT30
%TT31
%TT32
%TT33
%TT34
%TT40
%TT41
%TT42
%TT43
%TT44
%TT45
%TT46
%TT47
%TT48
%TT49
%TT4A
%TT4B
%TT4C
883
DTMF tone dial digits 0 to 9.
DTMF digit *.
DTMF digit #.
DTMF digit A.
DTMF digit B.
DTMF digit C.
DTMF digit D.
V.21 channel 1 mark (originate) symbol.
V.21 channel 2 mark symbol.
V.23 backward channel mark symbol.
V.23 forward channel mark symbol.
V.22 originate (call mark) signalling at 1200 bps.
V.22 bis originate (call mark) signalling at 2400 bps.
V.22 answer signalling (guard tone if PTT required).
V.22 bis answer signalling (guard tone if required).
V.21 channel 1 space symbol.
V.21 channel 2 space symbol.
V.23 backward channel space symbol.
V.23 forward channel space symbol.
V.32 9600 bps.
V.32 bis 14400 bps.
Silence (on-line), i.e., go off-hook.
V.25 answer tone.
1800 Hz guard tone.
V.25 calling tone (1300 Hz).
Fax calling tone (1100 Hz).
V.21 channel 2
V.27 ter 2400 bps
V.27 ter 4800 bps
V.29 7200 bps
V.29 9600 bps
V.17 7200 bps long train
V.17 7200 bps short train
V.17 9600 bps long train
V.17 9600 bps short train
V.17 12000 bps long train
V.17 12000 bps short train
V.17 14400 bps long train
V.17 14400 bps short train
3-21
AT Command Reference Manual
3.2.4.
AT\ Commands
\Kn - Break Control
Controls the response of the modem to a break received from the DTE or the remote modem or the \B command according
to the parameter supplied. The parameter value, if valid, is written to S40 bits 3, 4, and 5.
The response is different in three separate states.
The first state is where the modem receives a break from the DTE when the modem is operating in data transfer mode:
\K0
Enter on-line command mode, no break sent to the remote modem.
\K1
Clear data buffers and send break to remote modem.
\K2
Same as 0.
\K3
Send break to remote modem immediately.
\K4
Same as 0.
\K5
Send break to remote modem in sequence with transmitted data. (Default.)
The second case is where the modem is in the on-line command state (waiting for AT commands) during a data
connection, and the \B is received in order to send a break to the remote modem:
\K0
Clear data buffers and send break to remote modem.
\K1
Clear data buffers and send break to remote modem. (Same as 0.)
\K2
Send break to remote modem immediately.
\K3
Send break to remote modem immediately. (Same as 2.)
\K4
Send break to remote modem in sequence with data.
\K5
Send break to remote modem in sequence with data. (Same as 4.) (Default.)
The third case is where a break is received from a remote modem during a non-error corrected connection:
\K0
Clears data buffers and sends break to the DTE.
\K1
Clears data buffers and sends break to the DTE. (Same as 0.)
\K2
Send a break immediately to DTE.
\K3
Send a break immediately to DTE. (Same as 2.)
\K4
Send a break in sequence with received data to DTE.
\K5
Send a break in sequence with received data to DTE. (Same as 4.) (Default.)
Result Codes:
OK
ERROR
n = 0 to 5.
Otherwise.
3-22
883
AT Command Reference Manual
\Nn - Operating Mode
This command controls the preferred error correcting mode to be negotiated in a subsequent data connection. This
command is affected by the OEM firmware configuration.
\N0
Selects normal speed buffered mode (disables error-correction mode). (Forces &Q6.)
\N1
Serial interface selected - Selects direct mode and i s equivalent to &M0, &Q0 mode of operation.
(Forces &Q0.)
Parallel interface selected - Same as \N0.
\N2
Selects reliable (error-correction) mode. The modem will first attempt a LAPM connection and
then an MNP connection. Failure to make a reliable connection results in the modem hanging
up. (Forces &Q5, S36=4, and S48=7.)
\N3
Selects auto reliable mode. This operates the same as \N2 except failure to make a reliable
connection results in the modem falling back to the speed buffered normal mode. (Forces &Q5,
S36=7, and S48=7.)
\N4
Selects LAPM error-correction mode. Failure to make an LAPM error-correction connection
results in the modem hanging up. (Forces &Q5 and S48=0.) Note: The -K1 command can
override the \N4 command.
\N5
Selects MNP error-correction mode. Failure to make an MNP error-correction connection results
in the modem hanging up. (Forces &Q5, S36=4, and S48=128.)
Result Codes:
OK
ERROR
883
n = 0 to 5.
Otherwise.
3-23
AT Command Reference Manual
3.2.5.
AT+ Commands
+Hn - Enable/Disable RPI and DTE Speed
This command enables or disables Rockwell Protocol Interface (RPI) processing and sets the DTE speed.
+H0
Disable RPI.
+H1
Enable RPI and set DTE speed to 19200 bps.
+H2
Enable RPI and set DTE speed to 38400 bps.
+H3
Enable RPI and set DTE speed to 57600 bps.
Result Codes:
OK
n = 0 to 3.
ERROR
Otherwise.
……………..
+MS - Select Modulation
This extended-format command selects the modulation and, optionally, enables or disables automode, specifies the
lowest
and highest connection rates, selects m -Law or A-Law codec type, and enables or disables robbed bit signaling generation
(server modem) or detection (client modem) using one to five subparameters. The command format is:
+MS= <mod> [,[<automode>][,[<min_rate>][,[<max_rate>][,[<x_law>][,[< rb_signaling>]]]]]]<CR>
Notes:
1. For 14400 bps and lower speeds, the Nn command and S37 register can alternatively be used, in which case the +MS
subparameters will modified to reflect the Nn and S37=x settings. Use of the Nn and S37=x commands is not
recommended but is provided for compatibility with existing communication software. (S37 is not updated by the +MS
command.)
2. Subparameters not entered (enter a comma only or <CR> to skip the last subparameter) remain at their current values.
Reporting Selected Options
The modem can send a string of information to the DTE consisting of selected options using the following command:
+MS?
The response is:
+MS: <mod>,<automode>,<min_rate>,<max_rate>,<x_law>,<rb_signaling>
For example,
+MS: 56,1,300,56000,0,0 [RC56 default values]
+MS: 11,1,300,33600,0,0 [RC336 default values]
+MS: 10,1,300,14400,0,0 [RC144 default values]
Reporting Supported Options
The modem can send a string of information to the DTE consisting of supported options using the following command:
+MS=?
The response is:
+MS: (list of supported <mod> values), (list of supported <automode> values),(list of supported <min_rate>
values),
(list of supported <max_rate> values), (list of supported <x_law> values), (list of supported <rb_signaling> values)
For example,
+MS: (0,1,2,3,9,10,11,56, 64,69),(0,1),(300-33600),(300-56000),(0,1),(0,1) [RC56]
+MS: (0,1,2,3,9,10,11,64,69),(0,1),(300-33600),(300-33600),(0,1),(0,1) [RC336]
+MS: (0,1,2,3,9,10,64,69),(0,1),(300-14400),(300-14400),(0,1),(0,1) [RC144]
3-24
883
AT Command Reference Manual
Subparameter Definitions
1. <mod> = A decimal number which specifies the preferred modulation (automode enabled) or the modulation (automode
disabled) to use in originating or answering a connection. The options are:
<mod> Modulation
0
V.21
1
V.22
2
V.22 bis
3
V.23
9
V.32
10
V.32 bis
11
V.34
56
K56flex
Possible Rates (bps) 1
300
1200
2400 or 1200
1200
9600 or 4800
14400, 12000, 9600, 7200, or 4800
33600, 31200, 28800, 26400, 24000, 21600,
19200, 16800, 14400, 12000, 9600, 7200, 4800, or 2400
Notes
See Note 2
Default for RC144
Default for RC56/RC336/RC288
[RC56/RC336/RC288 only]
56000, 54000, 52000, 50000, 48000, 46000,
44000, 42000, 40000, 38000, 36000, 34000, 32000
300
1200
[RC56 only]
64
Bell 103
69
Bell 212
Notes:
1. See optional <automode>, <min_rate>, and <max_rate> subparameters.
2. For V.23, originating modes transmit at 75 bps and receive at 1200 bps; answering modes transmit at 1200 bps
and receive at 75 bps. The rate is always specified as 1200 bps.
The modem may also automatically switch to another modulation (automode), subject to the following constraints:
a. The modem may not be able to automatically switch from the current modulation (specified by <mod>) to some
other modulation. For example, there is no standard way to automode from Bell 103 to V.23.
b. The DTE may disable automode operation (see <automode> below).
c. The DTE may constrain the range of modulations available by specifying the lowest and highest rates (see
<min_rate> and <max_rate> below).
2. <automode> is an optional numeric value which enables or disables automatic modulation negotiation using V.8 bis/V.8
or V.32 bis Annex A. The options are:
<automode>
0
1
Option Selected
Notes
Automode disabled
Automode enabled using V.8 bis/V.8 or V.32 Annex A Default
The default value is 1, which enables automode. Note, however, there are modulations for which there is no automatic
negotiation, e.g., Bell 212 (<mod> = 69).
For <automode> = 0 (automode disabled, i.e., fixed modulation):
a. If <max_rate> is within the rates supported by the selected modulation, the selected rate is that specified by
<max_rate>. For example:
+MS=10,0,1200,4800 selects V.32 bis 4800 bps fixed rate.
b. If <max_rate> is greater than the highest speed supported by the modulation specified by <mod>, the starting
rate is the highest rate supported by the selected modulation. For example:
+MS=10,0,2400,14400 selects V.32 bis 14400, 12000, 9600, 7200, or 4800 bps.
c. To emulate issuance of the N0S37=x command sequence to select fixed mode operation, specify the
<max_rate> and <min_rate> both to be the (same) requested speed, and <mod> to be the modulation for that
speed. For example:
+MS=11,0,16800,16800 selects V.34 16800 bps fixed mode (no comparable S37 command).
+MS=10,0,12000,12000 selects V.32 bis 12000 bps fixed mode (same as N0S37=10).
883
3-25
AT Command Reference Manual
For <automode> = 1 (automode enabled, i.e., automatically selected speed and modulation):
The modem connects at th e highest possible rate in accordance with V.8 bis/V.8, or V.32 bis Annex A if V.8 bis/V.8 is
not supported by the remote modem.
a. If <max_rate> is greater than the highest rate supported by the modulation specified by <mod>, the modem
automodes down from the highest rate of the selected modulation. For example:
+MS=10,1,1200,24000 selects automoding down from V.32 bis 14400 bps.
b. To emulate issuance of the N1S37=x sequence command, specify the modulation and the rate to start
automoding down from using <mod> and <max_rate>, respectively. Set <min_rate> to 300 to allow automoding
all the way down to V.21 300 bps. For example:
+MS=11,1,300,16800 selects automode starting at V.34 16800 bps (no comparable S37 command).
+MS=9,1,300,12000 selects automode starting at V.32 bis 12000 bps (same as N1S37=10).
3. <min_rate> is an optional number which specifies the lowest rate at which the modem may establish a connection. The
value is decimal coded, in units of bps, e.g., 2400 specifies the lowest rate to be 2400 bps. The default is 300 for
300 bps.
4. <max_rate> is an optional number which specifies the highest rate at which the modem may establish a connection. The
value is decimal coded, in units of bps, e.g., 14400 specifies the highest rate to be 14400 bps. The default is 28800 for
28800 bps.
5. <x_law> is an optional number which specifies the codec type. The options are:
0 = m-Law
1 = A-Law
Note that ATZ will reset the <x_law> selection to 0 (m-Law).
6. <rb_signaling> is an optional number which enables or disables robbed bit signaling generation in a server modem or
enables or disables robbed bit signaling detection in a client modem. The options are:
0 = Robbed bit signaling generation (server modem ) or detection (client modem) disabled (default)
1 = Robbed bit signaling generation (server modem ) or detection (client modem) enabled
Note that ATZ will reset the <rb_signaling> selection to 0 (disabled).
Result Codes:
OK Valid subparameter string
ERROR Otherwise.
……………..
3-26
883
AT Command Reference Manual
3.2.6.
AT** Command
** - Download to Flash Memory
The linear flash memory downloader in the modem firmware allows flash memory connected to the modem external
memory bus to be upgraded with revised modem firmware. This process transfers (uploads) the upgraded modem
firmware (data) from the host computer to the modem which transfers (downloads) the data to the flash memory device.
Note that this downloader function must be provided in modem MCU firmware initially installed in exte rnal flash memory,
i.e., the downloader does not support the programming of blank flash memory.
Programming the flash memory device is a two-step process.
1.
When the AT** command is issued, the modem firmware boot loader is invoked and the user will first load a flash
load module (FLM) into the modem's RAM. The FLM contains the programming algorithm for the flash memory device
being programmed and any messages that may be sent during the load process.
2.
The user will then load the new modem firmware which the FLM will then program into the flash memory device.
Procedure:
1.
Install in the modem a flash memory programmed with the RC288ACn firmware; ensure that the flash memory device
is programmed with the sector secure mode set to UNSECURE, otherwise the device cannot be re-programmed in
the modem.
2.
Put the XXXFLM.S37 file and the new RC288AXX.S37 file in an appropriate directory on the computer's hard disk.
3.
Configure the communications application program for a DTE rate of between 9600 bps and 57600 b ps (57600 bps is
faster) and RTS/CTS flow control. A load at 57600 bps will take approximately 2 minutes; a load at 19200 bps will take
approximately 6 minutes.
4.
Check the modem for response by typing AT.
5.
Initiate the download process using the AT**n command, where:
AT** or AT**0
Download speed is the last sensed speed (recommended command).
AT**1
Download speed is 38.4k bps.
AT**2
Download speed is 57.6k bps.
The "Download Initiated" message appears upon issuing the AT**n command.
6.
Perform an ASCII upload of the XXXFLM.S37 file (e.g., AMDFLM.S37) from the host computer to the modem RAM using
an industry standard communications software or an equivalent process (ensure that all ASCII translation or pacing is
turned off).
To abort the load at this point, wait for the FLM download process to time-out, send a bad S37 record, or reset (POR)
the modem. If the load process times -out, the modem must be reset (ATZ) before the FLM can be loaded again.
7.
After the FLM has been loaded, perform an ASCII upload of the new modem firmware hex file (e.g., RC288ACi.S37)
(within 20 seconds, or the load will time-out) from the host computer to the modem RAM using an industry standard
communications software or an equivalent process. There will be a 3-second pause after the first record of the
RC288AXX.S37 file is sent, which is the FLASH erase cycle. There is no turning back at this point.
If the flash download fails (because of a bad .S37 record for example) or the upload is aborted, as long as the modem
is not turned off or reset, it will remain in the flash load cycle and the upload can be re-attempted at step 7.
A "Wrong Device" message is displayed if an incorrect FLM is used. In this case, restart at step 5 and upload the
correct FLM file.
A "Wrong Hex file or flow control" message is displayed if an incompatible hex file format is used (non-Motorola S3
format) or if the DTE ignores flow control (the flash download uses both Xon/Xoff and RTS/CTS flow control). If the
wrong format was used, reinitiate the u poad at step 7 using a correct firmware hex file.
8.
883
A "Device successfully programmed" message is displayed by the FLM at the completion of a successful download
and the modem will do a cold start.
3-27
AT Command Reference Manual
3.2.7.
AT- Commands
-SDR=n - Enable/Disable Distinctive Ring
This command enables or disables detection and reporting of distinctive ring. The syntax is AT-SDR=n, where n is a
number from 0 to 7. One, two, or three distinctive ring types can be simultaneously enabled depending upon the value of n
(bit mapped). The detected ring type is reported in the long form (verbose) of the result code by appending the ring type
number to the end of the RING message.
-SDR=0
-SDR=1
-SDR=2
-SDR=3
-SDR=4
-SDR=5
-SDR=6
-SDR=7
Disables Distinctive Ring. Any valid ring detected is reported as RING (default).
Enables Dis tinctive Ring Type 1.
Enables Distinctive Ring Type 2.
Enables Distinctive Ring Type 1 and 2.
Enables Distinctive Ring Type 3.
Enables Distinctive Ring Type 1 and 3.
Enables Distinctive Ring Type 2 and 3.
Enables D istinctive Ring Type 1, 2, and 3.
Result Codes:
OK
n = 0 to 7.
ERROR
Otherwise.
The n value bit map is:
Bit 0=1
Enable RING type 1. RING type 1 is detected and reported as RING1.
Bit 1=1
Enable RING type 2. RING type 2 is detected and reported as RING2.
Bit 2=1
Enable RING type 3. RING type 3 is detected and reported as RING3.
The ring types supported and the corresponding ring cadence detect criteria are:
Distinctive Ring
Type
Ring Cadence Detect Criteria
1
2.0 sec ON, 4.0 sec OFF.
2
0.8 sec ON, 0.4 sec OFF, 0.8 sec ON, 4.0 sec OFF.
3
0.4 sec ON, 0.2 sec OFF, 0.4 sec ON, 0.2 sec OFF, 0.8 sec ON, 4.0 sec OFF.
Notes:
1.
The Ring Indicate (RI) output does not toggle on the first ring if AT-SDR?0.
2.
The RI output waveform is the same for all ring types detected, i.e., RI is on for the total duration of the ring period.
3-28
883
AT Command Reference Manual
3.3.
3.3.1.
ERROR DETECTION AND DATA COMPRESSION COMMANDS
AT% Commands
%C - Enable/Disable Data Compression
Enables or disables data compression negotiation. The modem can only perform data compression on an error corrected
link. The parameter value, if valid, is written to S41 bits 0 and 1.
%C0
Disables data compression. Resets S46 bit 1.
%C1
Enables MNP 5 data compression negotiation. Resets S46 bit 1.
%C2
Enables V.42 bis data compres sion. Sets S46 bit 1.
%C3
Enables both V.42 bis and MNP 5 data compression. Sets S46 bit 1. (Default.)
Result Codes:
OK
ERROR
3.3.2.
n = 0, 1, 2, or 3.
Otherwise.
AT\ Commands
\An - Select Maximum MNP Block Size
The modem will operate an MNP error corrected link using a maximum block size controlled by the parameter supplied.
The parameter value, if valid, is written to S40 bits 6 and 7.
\A0
64 characters.
\A1
128 characters. (Default.)
\A2
192 characters.
\A3
256 characters.
Result Codes:
OK
ERROR
n = 0 to 3.
Otherwise.
\Bn - Transmit Break to Remote
In non-error correction mode, the modem will transmit a break signal to the remote modem with a length in multiples of 100
ms according to parameter specified. If a number in excess of 9 is entered, 9 is used. The command works in conjunction
with the \K command.
In error correction mode, the modem will signal a break through the active error correction protocol, giving no indication of
the length.
\B1-\B9
Break length in 100 ms units. (Default = 3.) (Non-error corrected mode only.)
Result Codes:
OK
NO CARRIER
If connected in data modem mode.
If not connected or connected in fax modem mode.
Note: When the modem receives a break from the remote modem, break is passed to the DTE as follows: In non-error
correction mode direct, the break length is passed; in non-error correction mode normal and in error correction mode, a
300 ms break is passed.
883
3-29
AT Command Reference Manual
3.4.
MNP 10 COMMANDS
3.4.1.
AT) Commands
)Mn - Enable Cellular Power Level Adjustment
Enables or disables automatic adjus tment of the transmit power level to accommodate the signalling requirements of
cellular telephone equipment. S40 bit 2 and S201 bit 6 are reset when )M0 is active; S40 bit 2 is set and S201 bit 6 is reset
when )M1 is active; S40 bit 2 and S201 bit 6 are set when )M2 is active.
)M0
Disables transmit power level adjustment during MNP 10 link negotiation. The )M0 command
allows transmit power adjustment if cellular operation is requested by the remote modem. Uses
wireline power level for initial cellular connection. (Default.)
)M1
Enables transmit power level adjustment during MNP 10 link negotiation. Uses the @Mn value,
or the value from the cellular driver (see 3.7) when operating in direct connect mode, to establish
initial cellular connection. After connection, the optimal power level is determined by the modem.
NOTE: )M1 should not be used with *H2.
)M2
Enables transmit power level adjustment during MNP 10 link negotiation. Uses the @Mn value,
or the value from the cellular driver (see 3.7) when operating in direct connect mode, to establish
initial cellular connection. After connection, the power level remains fixed.
Result Codes:
OK
ERROR
n = 0 to 2.
Otherwise.
Notes:
1.
For both cellular and land based modems in both originate or answer modes, if eith er )M1 or )M2 is set, the transmit
power level used for non-MNP 10 or fax connections is either the @Mn value or the value from the cellular driver (see
3.7).
2.
Power Level Considerations. The following tables define the power levels chosen for each mode of operation. The
transmit power levels are given in the form initial/final, where initial is the power level of the handshake at V.22 in *H1
modes or the power level of the initial V.32 bis handshake in *H0 or *H2 modes, and final is the power level of th e
subsequent V.32 bis handshake in *H1 modes or the power level after a retrain in *H0 or *H2 modes. A power level
indicated by "<" means that the final power level is adjusted from the preferred level by the dynamic transmit level
adjustment (DTLA) algorithm.
Cellular Modem (Remote Modem also MNP 10 Compatible)
*H1)M1
*H2)M1
*H1)M2
*H2)M2
@M0
Local Configuration -->
-10/<-26
-26/<-26
-10/-26
-26/-26
@M1
-10/<-30
-30/<-30
-10/-30
-30/-30
@M10
-10/<-10
-10/<-10
-10/-10
-10/-10
@Mn (n = 11 to 30)
-10/<-n
-n/<-n
-10/-n
-n/-n
Land Modem
Local Configuration -->
Remote Configuration -->
*H0)M0
*H0)M1
*H0)M2
*H0)M0
*H1)M1 or
*H1)M2
*H2)M1 or
*H2)M2
*H0, *H1, or *H2
*H0, *H1, or *H2
@M0
-10/-10
-10/<-26
NR
-26/<-26
-26/-26
@M1
-10/-10
-10/<-30
NR
-30/<-30
-30/-30
@M10
-10/-10
-10/<-10
NR
-10/<-10
-10/-10
@Mn (n = 11 to 30)
-10/-10
-10/<-n
NR
-n/<-n
-n/-n
Notes:
1. NR = Not Recommended.
2. In direct connect mode, the cellular driver value is used in place of the @Mn value; DTLA still functions in direct connect mode when
)M1 is set, but it would be better to use )M2.
3-30
883
AT Command Reference Manual
*Hn - Link Negotiation Speed
This command controls the connection speed for link negotiations before upshift occurs between two MNP 10 modems.
The parameter value, if valid, is written to S28 bits 6 and 7.
*H0
Link negotiation occurs at the highest supported speed. (Default.)
*H1
Link negotiation occurs at 1200 bps; used primarily for establishing cellular connections.
*H2
Link negotiation occurs at 4800 bps; used primarily to negotiate an MNP 10 connection on less
than average quality telephone lines.
Result Codes:
OK
ERROR
n = 0 to 2.
Otherwise.
-Kn - MNP Extended Services
Enables or disables conversion of a V.42 LAPM connection to an MNP 10 connection. The parameter value, if valid, is
written to S40 bits 0 and 1.
-K0
Disables V.42 LAPM to MNP 10 conversion.
-K1
Enables V.42 LAPM to MNP 10 conversion. (Default.)
-K2
Enables V.42 LAPM to MNP 10 conversion; inhibits MNP Extended Services initiation during V.42
LAPM answer mode detection phase.
Result Codes:
OK
ERROR
n = 0 or 2.
Otherwise.
-Qn - Enable Fallback to V.22 bis/V.22
Enables or disables fallback from MNP 10 to V.22 bis/V.22. The parameter value, if valid, is written to S41 bit 1.
-Q0
Disables fallback to 2400 bps (V.22 bis) and 1200 bps (V.22). Fallback is enabled only to 4800
bps.
-Q1
Enables fallback to 2400 bps (V.22 bis) and 1200 bps (V.22). (Default.)
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
-SEC=n - Enable/Disable MNP10-EC
Enables or disables MNP10-EC operation. The command format is:
-SEC=n,[<tx level>]
where <tx level> is the optional transmit level sub parameter.
-SEC=0
Disable MNP10-EC; the transmit level is that defined in S91.
-SEC=1,[<tx level>]
Enable MNP10-EC; the transmit level will be defined by the sub parameter <tx level>
range 0 to 30 (0 dBm to -30 dBm), the default <tx level> (<tx level> not specified) is the
S91 value.
Result Codes:
OK
ERROR
n=0, 1, or 1 and <tx level>=0 to 30
Otherwise
Example: AT-SEC=1,18 enables MNP10-EC and sets the transmit level to -18 dBm.
Note: If AT-SEC=0 the modem will automatically set AT-SEC=1 if the remote modem indicates Cellular in the V.8 phase.
Inquiries
AT-SEC?
883
Retrieves the current -SEC command settings, e.g., 1,18.
3-31
AT Command Reference Manual
@Mn - Initial Cellular Power Level Setting
Sets the initial transmit power level for upshift at connect until line conditions can be determined. @M0 corresponds to 26 dBm, @M1 corresponds to -30 dBm, @M2 through @M10 correspond to -10 dBm, and @M11 through @M30
correspond to -11 dBm to -30 dBm, respectively. The parameter value, if valid, is written to S201 bits 0-4.
@M0
-26 dBm (Default.)
@M1
-30 dBm
@M2
-10 dBm
@M3 - @M10
-10 dBm
@M11
-11 dBm
@M12
-12 dBm
.
.
.
@M30
-30 dBm
Result Codes:
OK
ERROR
n = 0 to 30.
Otherwise.
:E - Compromise Equalizer Enable Command
Enables or disables the V.32 compromise equalizer. The parameter value, if valid, is written to S201 bit 5. This command
can be used when the modem is attached to either a flat line or a cellular connection.
:E0
Disables the equalizer
:E1
Enables the e qualizer (Default.)
Result Codes:
OK
ERROR
n = 0 or 1.
Otherwise.
3-32
883
AT Command Reference Manual
3.5.
3.5.1.
W-CLASS COMMANDS
AT* Commands
*B - Display Blacklisted Numbers
This command requests the modem to return a list of blacklisted numbers to the DTE. The format of the response is
shown by the example below. Permanently forbidden numbers as defined by country requirements will not appear on this
list. If no numbers are blacklisted, only the OK result code is issued.
Example:
NO. - PHONE NUMBER ------ -----------------------------1;
2;
3;
4;
5;
4175537660
8288924961
3887278862
3124839442
6284664
OK
*D - Display Delayed Numbers
This command causes the modem to send a list of the delayed numbers together with the delay associated with each. The
modem will return a list of delayed telephone numbers as defined in the *B command. The format of the response is
shown by the example below (delay times are shown as hours:minutes:seconds). If no numbers are delayed, only the OK
result code is issued.
Example:
NO. - PHONE NUMBER -DELAY
------ ------------------------------------------1;
2;
3;
4;
5;
8264734660
7532634661
2587334662
7532651663
7459931664
2:00:00
2:00:00
0:02:00
0:03:25
0:01:45
OK
883
3-33
AT Command Reference Manual
*NCn - Country Select
Up to four sets of country parameters may be stored in the EPROM. This command checks to see if the entered number
matches the country code of one of the countries stored in the EPROM. If found, the modem stores the location of that
country in NVRAM. Upon power up or a soft reset (Z command), the modem uses this location to load the parameters for
the corresponding country. The default value of zero is used if no NVRAM is installed or the NVRAM failed self test during
reset.
Note: Automatic DAA country code recognition is enabled by the *NC0 command (the 0 country code is reserved for this
function). Automatic DAA country code recognition is disabled by the *NCn command selecting any other valid country code.
*NCn
Select country parameters corresponding to entered country code (n). The country codes are:
Country
Australia
Austria
Belgium
Bulgaria
Canada
Czech Republic
Denmark
Finland
France
Germany
Greece
Hungary
Ireland
Israel
Italy
Japan
Luxembourg
Mexico
Netherlands
New Zealand
Norway
Poland
Portugal
Russia
Singapore
Slovac Republic
Spain
Sweden
Switzerland
United Kingdom
United States
Code (n)
40
1
2
27
20
19
3
4
5
6
17
23
7
18
8
43
9
21
10
48
11
24
12
25
47
26
13
14
15
16
22
Result Codes:
OK
ERROR
If parameters corresponding to entered country code are present in EPROM.
Otherwise.
3-34
883
AT Command Reference Manual
3.6.
CALLER ID COMMANDS
3.6.1.
AT#CID Command
#CIDn - Caller ID
Enables or disables Caller ID.
#CID=0
Disables Caller ID. (Default.)
#CID=1
Enables Caller ID with formatted presentation to the DTE. The modem will present the data
items in a <Tag><Value> pair format. The expected pairs are data, time, caller code (telephone
number), and name.
#CID=2
Enables Caller ID with unformatted presentation to the DTE. The modem will present the entire
packet of information, excluding the leading U's, in ASCII printable hex numbers.
Result Codes:
OK
ERROR
n = 0 or 2.
Otherwise.
Inquiries
#CID?
Retrieves the current Caller ID mode from the modem.
#CID=?
Returns the mode capabilities of the modem in a list with each element separated by commas.
Formatted Form Reporting
The modem presents the data in the <tag> = <value> pair format as described in the table below. Spaces are present on
both sides of the equal sign.
Tag
Description
DATE
DATE = MMDD where MM is the month number (01 to 12) and DD is the day number (01..31).
TIME
TIME = HHMM where HH is the hour number (00 to 23) and MM is the minute number (00 to 59).
NMBR
NMBR = <number> or P or O where <number> is the telephone number of the caller, where P
indicates that the calling number information is not available since the originating caller has
requested private service, and where O indicates that the calling number information is not
available or out of service at the calling location.
NAME
NAME = <listing name> where <listing name> is the subscription name.
MESG
MESG = <data tag> <length of message> <data> <checksum> in printable ASCII hex numbers.
This tag indicates a data item not listed above. The message is only possible for Multiple
Message Format.
Notes:
1.
The modem does not present any Caller ID informati on if the DCE detects a checksum error in the Caller ID packet.
2.
In the event of an unrecognized data tag, the modem will present the data in ASCII hex numbers following the MESG
tag.
883
3-35
AT Command Reference Manual
Example of Formatted Form Reporting
1.
The following example illustrates the standard Caller ID message packet.
RING
DATE
TIME
NMBR
NAME
=
=
=
=
0321
1405
5045551234
A N OTHER
RING
RING
2.
The following example illustrates the case where the tag of the packet is not recognized by the modem.
RING
MESG
= 060342424231
RING
RING
Unformatted Form Reporting
The modem presents all information and packet control information found in the message. The modem, however, excludes
the leading U's (channel seizure information) from the presentation. The packet is presented in ASCII printable hex
numbers, the modem does not insert spaces, or line feeds, for formatting between bytes or words of the packet.
The modem does not detect the checksum of the packet.
Example of Unformatted Form Reporting
RING
0412303332323234303539313435353132333435
RING
RING
3-36
883
AT Command Reference Manual
3.7.
CELLULAR COMMANDS
The Direct Connect Modem allows a direct interface to most cellular telephones eliminating the need for other intelligent
interfaces.
Landline modems operate with the telephone system by either going off hook detecting dialtone and the dialing the
telephone number using pulses or DTMF digits, or detecting the RING signal and answering the call. Intelligent cellular
phone interfaces connect between the modems RJ-11 socket and the cellular phone's data interface. The interface
provides landline features to the modem (line current, dial tone, ringing, etc.), and translates the modem's signals (off hook,
DTMF digits, etc.) into signals that the cellular phone understands. Once connected the interface acts as a transparent link
between the modem and the cellular telephone.
The Direct Connect Modem interfaces directly to the cellular phone's data interface and provides direct control over the
cellular phones operation. For example if the user were to instruct the modem to dial using the ATDTnnnn command the
modem would relay the telephone number and the SEND command to the cellular phone over the data interface.
The modem connects to the cellular phone using a special cable which must be purchased separately. A different cable is
required for each cellular phone or make of cellular phones. Below is a block diagram of a typical Direct Connect Cellular
Modem (based on AK14-X270 Rev 4 reference schematic).
3.7.1.
Cellular Phone Drivers
The data interface to cellular phones differs between manufacturers and models and requires a unique cellular phone
driver for each phone or group of phones. Therefore the particular phone driver needs to be downloaded from the PC into
the modem's RAM before the modem can be used directly with the cellular phone. If a driver is not loaded the modem will
operate as a normal landline modem.
3.7.2.
Cellular Commands
^C2 - Download Cellular Phone Driver
The ^C2 command initiates the cellular phone driver download function. Upon receipt of the command, the modem issues
the "OK" message. The user then performs an ASCII download of the driver (in .S37 format) from the host to the modem,
typically using a communications software package (with transmit pacing turned off).
^C2
Download Cellular Phone command
Result Codes:
OK
[Download Process]
OK
Cellular phone driver download completed successfully
ERROR
Cellular phone driver download not completed successfully, e.g., checksum of record (in S37 file)
is not correct, driver size is larger than 2k bytes, or an invalid driver is downloaded, or modem is
connected.
^I - Identify Cellular Phone Driver
The modem reports the identification of the loaded cellular phone driver in response to the ^I command. The response is
dependent upon the driver.
Result Codes (Typical):
CELLULAR DRIVER: OKI 900/910
(c) Copyright 1994, Spectrum Cellular, Inc.
Version 0.07 Thu Jan 10:29:52 1994
OK
or
ERROR
Cellular phone driver is not loaded
883
3-37
AT Command Reference Manual
^T6 - Indicate Status of Cellular Phone
The status of the cellular phone connected to the modem is reported in response to the ^T6 command. The status is
reported in a single byte formatted as a decimal number. The individual status signals assigned to the status byte bits are:
bit 0
1=
Cellular phone is receiving an incoming call
bit 1
1=
Cellular phone is in use
bit 2
1=
Cellular phone is locked (cannot be used)
bit 3
1=
There is no service for cellular phone (does not indicate signal strength)
bit 4
1=
Cellular phone is powered on
bit 5
1=
Cellular driver is initialized
bit 6
0=
Reserved (0)
bit 7
1=
Cellular cable detected
Result Codes (typical):
128
OK
(Cellular cable detected)
Application of ^T6 Status Byte
The information obtained by issuing a AT^T6 can be used to determine if the loading of the cellular phone driver is
necessary by the host software. A download is not necessary if landline (or no cable) is connected to the modem, in which
^T6 will return a value of 0 (bit 7=0). A download is necessary when a cellular cable is detected (implied cellular phone is
also connected), in which ^T6 will return a value of 128 (bit 7=1). Once a driver is downloaded to the modem, it will be able
to operate in landline or cellular mode based on detection of a cellular cable.
3.7.3.
Operation
Once the driver is loaded and the modem is connected to the cellular phone, and the phone is powered on dial/answer
functions will be routed through the phone instead of the landline DAA, i.e., no special commands are needed to place or
answer calls, the same AT commands and software packages that are used for l andline communication sessions can be
used. If the cellular phone is not connected or is powered off dial/answer functions will be routed through the landline DAA,
and if V.42 bis connection is established the cellular phone driver will be purged so that the V.42 bis dictionaries can be
increased to their normal size.
While the modem is being used with a cellular phone it will respond with normal result messages with the following
differences in meaning:
NO DIALTONE
RING
Indicates that cellular service is not currently available.
Indicates that the cellular phone is receiving an incoming call.
Modem Configuration
Modem performance will be improved by modification of your standard configuration, it is recommended that the landline
modem also be MNP10 EC compatible for reliable communications.
MNP10 EC to MNP10 EC Connection
Cell Site
AT -SEC=1,12 &C1 &D2
(optional for the connect message: AT S95=46)
Base Site
AT -SEC=1,18 &C1 &D2
(optional for the connect message: AT S95=46)
MNP10 EC to MNP10 Link Negotiation at 4800 bps (Quick Connect)
Cell Site
AT -SEC=1,12 &C1 &D2
(optional for the connect message: AT S95=46)
Base Site
AT&F )M2 @M18 &C1 &D2
(optional for the connect message: AT S95=46)
AT -SEC=1,12 will put the modem into EC mode, the transmit level will be -12 dBm. The optimum trnsmit level will depend
on the phone being used.
3-38
883
AT Command Reference Manual
MNP10 EC to Non-MNP10 Modems
If calls are made from a cellular modem to a landline modem that does not support MNP10 EC or MNP10 EC the following
configuration is recommended:
AT -SEC=1,12 %E2
If calls cannot reliably be made using the above configuration, it may be necessary to force the connection to 9600 bps or
slower using the following configuration string:
AT -SEC=1,12 %E2 N1 S37=9
(V.32 bis modems) or
AT -SEC=1,12 %E2 +MS=11,1,300,9600
(V.34 modems)
Disabling MNP10 EC
AT -SEC=0 will disable MNP10 EC, however if the remote modem indicates cellular during the V.8 negotiation AT-SEC=1
will automatically be set (V.34 only).
Fax Configuration
It is recommended that fax transmissions be configured to operate at 9600 bps in V.17 mode or 7200 bps in V.29 mode.
Cellular Phone Configuration
To achieve the best operational performance, a cellular data connection should be attempted in a location where adequate
signal strength is observed for the cellular phone. This condition can be easily monitored on some phones with signal
strength indicator. In locations where even voice calls are unreliable, data connections should not be attempted. Under
some circumstances a special high gain antenna may improve performance.
Additional information regarding the use of the cellular phone and cellular network should be obtained from the service
provider and or cellular phone manufacturer.
883
3-39
AT Command Reference Manual
3.8.
AT COMMAND RESULT CODES
The modem responds to commands from the DTE and to activity on the line by signalling to the DTE in the form of result
codes. The result codes that the modem can send are described below.
Two forms of each result code are available: long-form, an English-like "verbose" response, and short-form, a data-like
numeric response (included in parentheses following the long-form). The long-form code is preceded and terminated by
the sequence < CR> < LF>. The short-form is terminated by < CR>, only with no preceding sequence.
If result messages are suppressed, nothing is returned to the DTE. The long-form results codes can be modified by the
OEM through the ConfigurACE Configuration Utility Program. (See ConfigurACE description.)
0- OK
The OK code is returned by the modem to acknowledge execution of a command line.
1- CONNECT
The modem will send this result code upon connecting when:
1.
The line speed is 300 bps and the modem has been instructed to report the line speed to the DTE upon connecting,
or
2.
The DTE speed is 300 bps and the modem has been instructed to report the DTE speed to the DTE upon connecting,
or
3.
The range of result code responses is restricted by the X command such that no speed reporting is allowed.
2- RING
The modem sends this result code when incoming ringing is detected on the line. What qualifies as a ring signal is
determined by country-dependent parameters, modifiable through ConfigurACE.
When cellular interface is selected, RING indicates that the cellular phone is receiving an incoming call.
3- NO CARRIER
The modem sends this result code when attempting to establish a call if:
1.
Ringback is detected and later ceases but no carrier is detected within the period of time determined by register S7, or
2.
No ringback is detected within the period of time determined by regis ter S7.
This result code is also used when the modem auto -disconnects due to loss of carrier.
Under X0, if busy tone detection is enforced, this result code is used as a response to the detection of busy or circuit busy.
Under X0, if dial tone detection is enforced or selected, this result code is used to indicate that dial tone has not been
detected.
4- ERROR
The modem returns this result code if the command line contains a syntax error or it is unable to execute a command
contained in the command line. It is issued if a command does not exist or if the parameter supplied is outside the
permitted range.
Under X0, X1, X2, and X3, this result is used instead of DELAYED and BLACKLISTED.
5- CONNECT 1200
For X1, X2, X3, and X4, the modem sends this result code when:
1.
The line speed is 1200 bps and the modem has been instructed to report the line speed to the DTE upon connecting,
or
2.
The DTE speed is 1200 bps and the modem has been instructed to report the DTE speed to the DTE upon
connecting.
(Also, see the W command.)
3-40
883
AT Command Reference Manual
6- NO DIALTONE
For X2 and X4, the modem sends this result code if it has been instructed to wait for dial tone during dialing but none is
received.
When cellular phone interface is selected, NO DIALTONE indicates that cellular service is not currently available.
7- BUSY
For X3 and X4, if busy tone detection is enforced, the modem sends this result code when attempting to originate a call if
the busy (engaged) signal is detected on the line.
8- NO ANSWER
The modem sends this result code when attem pting to originate a call if a continuous ringback signal is detected on the
line until the expiration of the timer S7.
9- CONNECT 0600
For X1, X2, X3, and X4, the modem sends this result code when:
1.
The line speed is 600 bps and the modem has been instructed to report the line speed to the DTE upon connecting,
or
2.
The DTE speed is 600 bps and the modem has been instructed to report the DTE speed to the DTE upon connecting.
10- CONNECT 2400
For X1, X2, X3, and X4, the modem sends this result code when:
1.
The line speed is 2400 bps and the modem has been instructed to report the line speed to the DTE upon connecting,
or
2.
The DTE speed is 2400 bps and the modem has been instructed to report the DTE speed to the DTE upon
connecting.
11- CONNECT 4800
For X1, X2, X3, and X4, the modem sends this result code when:
1.
The line speed is 4800 bps and the modem has been instructed to report the line speed to the DTE upon connecting,
or
2.
The DTE speed is 4800 bps and the modem has been instructed to report the DTE speed to the DTE upon
connecting.
12- CONNECT 9600
For X1, X2, X3, and X4, the modem sends this result code when:
1.
The line speed is 9600 bps and the modem has been instructed to report the line speed to the DTE upon connecting,
or
2.
The DTE speed is 9600 bps and the modem has been instructed to report the DTE speed to the DTE upon
connecting.
13- CONNECT 7200
For X1, X2, X3, and X4, the modem sends this result code when:
1.
The line speed is 7200 bps and the modem has been instructed to report the l ine speed to the DTE upon connecting,
or
2.
The DTE speed is 7200 bps and the modem has been instructed to report the DTE speed to the DTE upon
connecting.
14- CONNECT 12000
For X1, X2, X3, and X4, the modem sends this result code when:
1.
The line speed is 12000 bps and the modem has been instructed to report the line speed to the DTE upon
connecting, or
883
3-41
AT Command Reference Manual
2.
The DTE speed is 12000 bps and the modem has been instructed to report the DTE speed to the DTE upon
connecting.
15- CONNECT 14400
For X1, X2, X3, and X4, the modem sends this result code when:
1.
The line speed is 14400 bps and the modem has been instructed to report the line speed to the DTE upon
connecting, or
2.
The DTE speed is 14400 bps and the modem has been instructed to report the DTE speed to the DTE upon
connecting.
16- CONNECT 19200
For X1, X2, X3, and X4, the modem returns this result code upon connecting when the DTE speed is 19200 bps and the
modem has been instructed to report the DTE speed upon connecting.
17- CONNECT 38400
For X1, X2, X3, and X4, the modem sends this result code upon connecting when the DTE speed is 38400 bps and the
modem has been instructed to report the DTE speed to the DTE upon connecting.
18- CONNECT 57600
For X1, X2, X3, and X4, the modem sends this result code upon connecting when the DTE speed is 57600 bps and the
modem has been instructed to report the DTE speed to the DTE upon connecting.
19- CONNECT 115200
For X1, X2, X3, and X4, the modem sends this result code upon connecting when the DTE speed is 115200 bps and the
modem has been instructed to report the DTE speed to the DTE upon connecting.
22- CONNECT 75TX/1200RX
For X1, X2, X3, and X4, the modem returns this result code upon establishing a V.23 originate connection when the modem
has been instructed to report the DCE speed upon connection.
23- CONNECT 1200TX/75RX
For X1, X2, X3, and X4, the modem returns this result code upon establishing a V.23 answer connection when the modem
has been instructed to report the DCE speed upon connection.
24- DELAYED
For X4, the modem returns this result code when a call fails to connect and the number dialed is considered 'delayed' due
to country blacklisting requirements.
32- BLACKLISTED
For X4, the modem returns this result code when a call fails to connect and the number d ialed is considered 'blacklisted'.
33- FAX
The modem returns this result code when a fax modem connection is established in a facsimile mode.
35- DATA
The modem returns this result code when a data modem connection is established in a facsimile mode.
40- CARRIER 300
The modem returns this result code when a 0-300 bps data rate has been detected on the line and carrier reporting has
been enabled. (See S95 and Xn.)
44- CARRIER 1200/75
The modem sends this result code when the V.23 backward channel carrier has been detected on the line and carrier
reporting has been enabled. (See S95 and Xn.)
3-42
883
AT Command Reference Manual
45- CARRIER 75/1200
The modem sends this result code when the V.23 forward channel carrier has been detected on the line and carrier
reporting has been enabled. (See S95 a nd Xn.)
46- CARRIER 1200
The modem sends this result code when a 1200 bps data rate has been detected on the line and carrier reporting has
been enabled. (See S95 and Xn.)
47- CARRIER 2400
The modem sends this result code when a 2400 bps data rate has been detected on the line and carrier reporting has
been enabled. (See S95 and Xn.)
48- CARRIER 4800
The modem sends this result code when a 4800 bps data rate has been detected on the line and carrier reporting has
been enabled. (See S95 and Xn.)
49- CARRIER 7200
The modem sends this result code when a 7200 bps data rate has been detected on the line and carrier reporting has
been enabled. (See S95 and Xn.)
50- CARRIER 9600
The modem sends this result code when a 9600 bps data rate has been detected on the line and carrier reporting has
been enabled. (See S95 and Xn.)
51- CARRIER 12000
The modem sends this result code when a 12000 bps data rate has been detected on the line and carrier reporting has
been enabled. (See S95 and Xn.)
52- CARRIER 14400
The modem sends this result code when a 14400 bps data rate has been detected on the line and carrier reporting has
been enabled. (See S95 and Xn.)
66- COMPRESSION: CLASS 5
This message is sent to the DTE when the modem has connected in MNP Class 5 and COMPRESSION mes sage
reporting has been enabled. (See S95 and Xn.)
67- COMPRESSION: V.42 bis
This message is sent to the DTE when the modem has connected in V.42 bis and COMPRESSION message reporting has
been enabled. (See S95 and Xn.)
69- COMPRESSION: NONE
This message is sent to the DTE when the modem has connected without data compression and COMPRESSION
message reporting has been enabled. (See S95 and Xn.)
70- PROTOCOL: NONE
This message is sent to the DTE when the modem has connected without any form of error correcti on, and the PROTOCOL
message reporting has been enabled. (See S95 and Xn.)
77- PROTOCOL: LAPM
This message is sent to the DTE when the modem has connected in the V.42 LAPM mode of error correction, and
PROTOCOL message reporting has been enabled. (See S95 and Xn.)
80- PROTOCOL: ALT
This message is sent to the DTE when the modem has connected in the MNP mode of error correction, and PROTOCOL
message reporting has been enabled. (See S95 and Xn.)
883
3-43
AT Command Reference Manual
81- PROTOCOL: ALT-CELLULAR
This message is sent to the DTE when the modem has connected in the MNP 10 mode and cellular power level
adjustment is enabled (")M1 or )M2").(See S95 and Xn.)
+F4- +FCERROR
This message is sent to the DTE when high speed fax data (V.27, V.29, V.33, or V.17) is expected and a V.21 signal is
received.
3-44
883
AT Command Reference Manual
4.
S-REGISTERS
The S-Registers are summarized in Table 4 -1 along with their default values. Registers denoted with an '*' in Table 4-1 may
be stored in one of the two user profiles by entering the &Wn command. One of these profiles may be loaded at any time by
using the Zn command. Registers or register fields quoted as “reserved” are reserved for current or future use by the
firmware, or are permanently overridden by PTT limitations. For the latter, control of the equivalent functionality is available
with ConfigurACE Call Progress and Blacklisting options.
All bit-mapped registers are read-only. The appropriate AT command which controls the relevant bits in the S-Register
should be used to change the value.
4.1.
FACTORY DEFAULTS
The factory default values are stored in ROM and are loaded into the active configuration at power up or by the ATZn
command. In addition, the designated default profile is subsequently loaded, and may change some of the factory default
values. The designated default profile can be changed by entering the &Yn command where n is one of the two possible
user profiles.
The defaults shown are those used by Rockwell in factory profiles zero and one. These may be overwritten by the OEM with
ConfigurACE prior to placing the firmware in PROM. Minimum and maximum values may also be imposed by ConfigurACE
in response to country PTT requirements.
The default values shown in Table 4-1 may vary by modem firmware configuration. Consult the MCU firmware release
notes for exact configuration.
The factory default values may be loaded at any time by entering the &Fn command.
883
4-1
AT Command Reference Manual
Table 4-1.
Register
S0
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
S22
S23
S24
S25
S26
S27
S28
S29
S30
S31
S32
S33
S34-S35
S36
S37
S38
S39
Function
Rings to Auto-Answer
Ring Counter
Escape Character
Carriage Return Character
Line Feed Character
Backspace Character
Wait Time for Dial Tone
Wait Time for Carrier
Pause Time for Dial Delay Modifier
Carrier Detect Response Time
Carrier Loss Disconnect Time
DTMF Tone Duration
Escape Prompt Delay
Reserved
General Bit Mapped Options Status
Reserved
Test Mode Bit Mapped Options Status
(&T)
Reserved
Test Timer
AutoSync Options
AutoSync HDLC Address or BSC
Sync Character
V.24/General Bit Mapped Options
Status
Speaker/Results Bit Mapped Options
Status
General Bit Mapped Options Status
Sleep Inactivity Timer
Delay to DTR Off
RTS-to-CTS Delay
General Bit Mapped Options Status
General Bit-Mapped Options Status
Flash Dial Modifier Time
Disconnect Inactivity Timer
General Bit-Mapped Options Status
XON Character
XOFF Character
Reserved
LAPM Failure Control
Line Connection Speed
Delay Before Forced Hangup
Flow Control Bit Mapped Options
Status
S-Register Summary
Range
0-255
0-255
0-255
0-127
0-127
0-255
2-255
1-255
0-255
1-255
1-255
50-255
0-255
-
Units
rings
rings
ASCII
ASCII
ASCII
ASCII
s
s
s
0.1 s
0.1 s
0.001 s
0.02 s
-
0-255
0-255
s
-
-
Saved
*
*
*
*
*
*
*
*
*
*
Default**
0
0
43
13
10
8
2
50
2
6
14
95
50
138 (8Ah)
0
*
0
0
0
-
*
4 (04h)
-
-
*
117 (75h)
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
-
s
s or 0.01 s
0.01 s
10 ms
10 s
ASCII
ASCII
s
-
*
*
54 (36h)
0
5
1
9 (09h)
0
0
0
2
17 (11h)
19 (13h)
7
0
20
3
4-2
*
*
*
*
*
*
*
883
AT Command Reference Manual
Table 4-1.
S-Register Summary (Cont’d)
Register
S40
Function
General Bit-Mapped Options Status
-
Range
-
Units
*
Saved
S41
S42-S45
S46
S48
S82
S86
S91
S92
S95
S201
General Bit-Mapped Options Status
Reserved
Data Compression Control
V.42 Negotiation Control
LAPM Break Control
Call Failure Reason Code
PSTN Transmit Attenuation Level
Fax Transmit Attenuation Level
Result Code Messages Control
Cellular Transmit Level
0-255
0-15
0-15
0-63
dBm
dBm
-
*
*
*
*
*
* Register value may be stored in one of two user profiles with the &W command.
•• Default values may be modified using ConfigurACE.
883
4-3
Default**
105 (69h) (Non-MNP 10
models)
107(6Bh) (MNP 10 models)
3
138
7
128(40h)
10 (Country dependent)
10 (Country dependent)
0
58
AT Command Reference Manual
4.2.
S-REGISTER DEFINITIONS
S0 - Number of Rings to Auto-Answer
Sets the number of the rings required before the modem automatically answers a call. Setting this register to zero disables
auto-answer mode.
Range:
0-255 rings
Default: 0
S1 - Ring Counter
S1 is incremented each time the modem detects a ring signal on the telephone line. S1 is cleared if no rings occur over an
eight second interval.
Range:
0-255 rings
Default: 0
S2 - Escape Character
S2 holds the decimal value of the ASCII character used as the escape character. The default value corresponds to an ASCII
'+'. A value over 127 disables the escape process, i.e., no escape character will be recognized.
Range:
0-255, ASCII decimal
Default: 43 (+)
S3 - Carriage Return Character
Sets the command line and result code terminator character. Pertains to asynchronous operation only.
Range:
0-127, ASCII decimal
Default: 13 (Carriage Return)
S4 - Line Feed Character
Sets the character recognized as a line feed. Pertains to asynchronous operation only. The Line Feed control character is
output after the Carriage Return control character if verbose result codes are used
Range:
0-127, ASCII decimal
Default: 10 (Line Feed)
S5 - Backspace Character
Sets the character recognized as a backspace. Pertains to asynchronous operation only. The modem will not recognize the
Backspace character if it is set to a value that is greater than 32 ASCII. This character can be used to edit a command line.
When the echo command is enabled, the modem echoes back to the local DTE the Backspace character, an ASCII space
character and a second Backspace character; this means a total of three characters are transmitted each time the modem
processes the Backspace character.
Range:
0-32, ASCII decimal
Default: 8 (Backspace)
4-4
883
AT Command Reference Manual
S6 - Wait Time for Dial Tone Before Blind Dialing, or After “W” Dial Modifier (W-Class Models)
1.
Sets the length of time, in seconds, that the modem will wait before starting to dial after going off-hook when blind
dialing. This operation, however, may be affected by some ATX options according to country restrictions. The “Wait for
Dial Tone” call progress feature (W dial modifier in the dial string) will override the value in register S6.
2.
For W-class models, S6 sets the length of time, in seconds, that the modem will wait for dial tone when encountering
a “W” dial modifier before returning NO DIAL TONE result code.
The modem always pauses for a minimum of 2 seconds, even if the value of S6 is less than 2 s econds.
Range:
2-255 seconds
Default: 2
S7 - Wait Time For Carrier After Dial, For Silence, or For Dial Tone After “W” Dial Modifier (US Models)
1.
Sets the length of time, in seconds, that the modem will wait for carrier before hanging up. The timer is started when
the modem finishes dialing (originate), or 2 seconds after going off-hook (answer). In originate mode, the timer is
reset upon detection of answer tone if allowed by country restrictions.
2.
Sets the length of time, in seconds, that modem will wait for silence when encountering the @ dial modifier before
continuing with the next dial string parameter.
3.
For US models, S7 sets the length of time, in seconds, that the modem will wait for dial tone when encountering a “W”
dial modifier before continuing with the next dial string parameter.
Range:
1-255 seconds
Default: 50
S8 - Pause Time For Dial Delay
Sets the time, in seconds, that the modem must pause when the “,” dial modifier is encountered in the dial string.
Range:
0-255 seconds
Default: 2
S9 - Carrier Detect Response Time
Sets the time, in tenths of a second, that the carrier must be present before the modem considers it valid and turns on
RLSD. As this time is increased, there is less chance to detect a false carrier due to noise from the telephone line.
Range:
1-255 tenths of a second
Default: 6 (0.6 second)
S10 - Lost Carrier To Hang Up Delay
Sets the length of time, in tenths of a second, that the modem waits before hanging up after a loss of carrier. This allows for
a temporary carrier loss without causing the local modem to disconnect. When register S10 is set to 255, the modem
functions as if a carrier is always present.
The actual interval the modem waits before disconnecting is the value in register S10 minus the value in register S9.
Therefore, the S10 value must be greater than the S9 value or else the modem disconnects before it recognizes the carrier.
Range:
1-255 tenths of a second
Default: 14 (1.4 seconds)
S11 - DTMF Tone Duration
Sets the duration of tones in DTMF dialing (US models only). This value has no effect on pulse dialing.
For W-class models, this parameter is a country parameter loaded by ConfigurACE.
Range:
50-255 milliseconds
Default: 95 (95 milliseconds)
883
4-5
AT Command Reference Manual
S12 - Escape Prompt Delay (EPD)
Defines the maximum period, in fiftieths of a second, allowed between receipt of the last character of the three escape
character sequence from the DTE and sending of the OK result code to the DTE. If any characters are detected during this
time, the OK will not be sent. Note that sending of the OK result code does not affect entry into command mode. (See 3.1.3.)
Range:
0-255 1/50 of a second
Default: 50 (1 second)
S13 - Reserved
S14 - General Bit Mapped Options Status
Indicates the status of command options.
Default: 138 (8Ah) (10001010b)
Bit 0 —
This bit is ignored.
Bit 1 —
Command echo (En)
Bit 2 —
Bit 3 —
0=
Disabled (E0)
1=
Enabled (E1) (Default.)
Quiet mode (Qn)
0=
Send result codes (Q0) (Default.)
1=
Do not send result codes (Q1)
Result codes (Vn)
0=
Numeric (V0)
1=
Verbose (V1) (Default.)
Bit 4 —
Reserved
Bit 5 —
Tone (T)/Pulse (P)
0=
Tone (T) (Default.)
1=
Pulse (P)
Bit 6 —
Reserved
Bit 7 —
Originate/Answer
0=
Answer
1=
Originate (Default.)
S15 - Reserved
4-6
883
AT Command Reference Manual
S16 - General Bit Mapped Test Options Status
Indicates the test in progress status.
Default: 0
Bit 0 —
Local analog loopback
0=
Disabled (Default.)
1=
Enabled (&T1)
Bit 1 —
Not used
Bit 2 —
Local digital loopback
Bit 3 —
Bit 4 —
Bit 5 —
Bit 6 —
Bit 7 —
0=
Disabled (Default.)
1=
Enabled (&T3)
Remote digital loopback (RDL) status
0=
Modem not in RDL (Default.)
1=
RDL in progress
RDL requested (AT&T6)
0=
RDL not requested (Default.)
1=
RDL requested (&T6)
RDL with self test
0=
Disabled (Default.)
1=
Enabled (&T7)
Local analog loopback (LAL) with self test
0=
Disabled (Default.)
1=
Enabled (&T8)
Not used
S17 - Reserved
S18 - Test Timer
Sets the length of time, in seconds, that the modem conducts a test (commanded by &Tn) before returning to the command
mode. If this register value is zero, the test will not automatically terminate; the test must be terminated from the command
mode by issuing an &T0 or H command. When S18 is non-zero, the modem returns the OK message upon test
termination.
Range:
0-255 seconds
Default: 0
883
4-7
AT Command Reference Manual
S19 - AutoSync Bit Mapped Options
Defines the options for AutoSync operation (see &Q4 command). S19 must be set to the desired value before &Q4 is
issued.
Default: 0
Bit 0 —
Reserved
Bit 1 —
BSC/HDLC format select
Bit 2 —
Bit 3 —
Bit 4 —
Bits 5 - 7 —
0=
BSC selected (Default.)
1=
HDLC selected
Address detection enable/disable
0=
Disabled (Default.)
1=
Enabled
NRZI/NZI coding select
0=
NRZI (Default.)
1=
NZI
Idle indicator select
0=
Mark idle (Default.)
1=
Flag or sync idle
Reserved
S20 - AutoSync HDLC Address or BSC Sync Character
Defines the HDLC address (S19 bit 1 = 1) or BSC Sync Character (S19 bit 1 = 0) for AutoSync operation (see &Q4
command). S20 must be set to the desired value before &Q4 is issued.
Range:
0-255
Default: 0
4-8
883
AT Command Reference Manual
S21 - V.24/General Bit Mapped Options Status
Indicates the status of command options.
Default: 4 (00000100b)
Bit 0 —
0=
&J0 (Default.)
1=
&J1
Bit 1 —
Reserved
Bit 2 —
CTS behavior (&Rn)
Bits 3-4 —
Bit 5 —
Bit 6 —
Bit 7 —
883
Set by &Jn command but ignored otherwise.
0=
CTS tracks RTS (&R0)
1=
CTS always on (&R1) (Default.)
DTR behavior (&Dn)
0=
&D0 selected (Default.)
1=
&D1 selected
2=
&D2 selected
3=
&D3 selected
RLSD (DCD) behavior (&Cn)
0=
&C0 selected (Default.)
1=
&C1 selected
DSR behavior (&Sn)
0=
&S0 selected (Default.)
1=
&S1 selected
Long space disconnect (Yn)
0=
Y0 (Default.)
1=
Y1
4-9
AT Command Reference Manual
S22 - Speaker/Results Bit Mapped Options Status
Indicates the status of command options.
Default: 117 (75h) (01110101b)
Bits 0-1 —
Bits 2-3 —
Bits 4-6 —
Bit 7—
Speaker volume (Ln)
0=
Off (L0)
1=
Low (L1) (Default.)
2=
Medium (L2)
3=
High (L3)
Speaker control (Mn)
0=
Disabled (M0)
1=
Off on carrier (M1) (Default.)
2=
Always on (M2)
3=
On during handshake (M3)
Limit result codes (Xn)
0=
X0
4=
X1
5=
X2
6=
X3
7=
X4 (Default.)
Reserved
4-10
883
AT Command Reference Manual
S23 - General Bit Mapped Options Status
Indicates the status of command options.
Default:
54 (36h) (00110110b)
Bit 0—
Grant RDL
Bits 1-3 —
Bits 4-5 —
Bits 6-7 —
0=
RDL not allowed (&T5) (Default.)
1=
RDL allowed (&T4)
DTE Rate
0=
0 - 300 bps
1=
600 bps
2=
1200 bps
3=
2400 bps (Default.)
4=
4800 bps
5=
9600 bps
6=
19200 bps
7=
38400 bps or higher
Assumed DTE parity
0=
even
1=
not used
2=
odd
3=
none (Default.)
Guard tone (&Gn)
0=
None (&G0) (Default.)
1=
None (&G1)
2=
1800 Hz (&G2)
S24 - Sleep Inactivity Timer
Sets the length of time, in seconds, that the modem will operate in normal mode with no detected telephone line or DTE
line activity before entering low-power sleep mode. The timer is reset upon any DTE line or telephone line activity. If the S24
value is zero, neither DTE line nor telephone inactivity will cause the modem to enter the sleep mode.
Range:
0-255 seconds
Default: 0
S25 - Delay To DTR
Sets the length of time that the modem will ignore DTR for taking the action specified by &Dn. Its units are seconds for
synchronous modes and one hundredths of a second for other modes.
Range:
0-255 (1 second for synchronous modes 1; 0.01 second otherwise)
Default: 5
S26 - RTS to CTS Delay
Sets the time delay, in hundredths of a second, before the modem tu rns CTS ON after detecting an OFF-to-ON transition on
RTS when &R0 is commanded. Pertains to synchronous operation only.
Range:
0-255 hundredths of a second
Default: 1
883
4-11
AT Command Reference Manual
S27 - Bit Mapped Options Status
Indicates the status of command options.
Default: 9 (09h) (00001001b)
Bits 0,1,3 —
Bit 2 —
Bits 4 - 5 —
Bit 6 —
Synchronous/asynchronous selection (&Mn/&Qn)
3
1
0
0
0
0
=
&M0 or &Q0
0
0
1
=
&M1 or &Q1
0
1
0
=
&M2 or &Q2
0
1
1
=
&M3 or &Q3
1
0
0
=
&Q4
1
0
1
=
&Q5 (Default.)
1
1
0
=
&Q6
Leased line control (&Ln)
0=
Dial up line (&L0) (Default.)
1=
Leased line (&L1)
Internal clock select (&Xn)
0=
Internal clock (&X0) (Default.)
1=
External clock (&X1)
2=
Slave clock (&X2)
CCITT/Bell mode select (Bn)
0=
CCITT mode (B0) (Default.)
1=
Bell mode (B1)
Bit 7 - Reserved
4-12
883
AT Command Reference Manual
S28 - Bit Mapped Options Status
Default: 0
Bits 0-1 —
Reserved
Bit 2 —
Reserved (always 0).
Bits 3 - 4 —
Pulse dialing (&Pn)
0=
39%-61% make/break ratio at 10 pulses per second (&P0) (Default.)
1=
33%-67% make/break ratio at 10 pulses per s econd (&P1)
2=
39%-61% make/break ratio at 20 pulses per second (&P2)
3=
33%-67% make/break ratio at 20 pulses per second (&P3)
Bit 5 —
Reserved
Bits 6-7 —
MNP Link Negotiation Speed (*Hn)
0=
Link negotiation at highest speed (*H0) (Default.)
1=
Link negotiation at 1200 bps (*H1)
2=
Link negotiation at 4800 bps (*H2)
S29 - Flash Dial Modifier Time
Sets the length of time, in units of 10 ms, that the modem will go on-hook when it encounters the flash (!) dial modifier in the
dial string. The time can be limited as it is a country dependent parameter.
Range:
0-255 10 ms intervals
Default: 0 (disabled)
S30 - Disconnect Inactivity Timer
Sets the length of time, in tens of seconds, that the modem will stay online before disconnecting when no data is sent or
received. In error-correction mode, any data transmitted or received will reset the timer. In other modes, any data
transmitted will reset the timer. The timer is inoperative in synchronous mode.
Range:
0-255 tens of seconds (0-2550 seconds)
Default: 0 (disabled)
883
4-13
AT Command Reference Manual
S31 - Bit Mapped Options Status
Default: 2 (00000010b)
Bit 0 —
Reserved
Bit 1 —
Controls auto line speed detection (Nn)
Bits 2-3 —
0=
Disabled (N0)
1=
Enabled (N1) (Default.)
Controls error correction progress messages (Wn)
0=
DTE speed only (W0) (Default.)
1=
Full reporting (W1)
2=
DCE speed only (W2)
Bit 3 —
Reserved
Bits 4-7 —
Reserved
S32 - XON Character
Sets the value of the XON character.
Range:
0-255, ASCII decimal
Default: 17 (11h)
S33 - XOFF Character
Sets the value of the XOFF character.
Range:
0-255, ASCII decimal
Default: 19 (13h)
S34-S35 - Reserved
S36 - LAPM Failure Control
Default: 7 (00000111b)
Bits 0-2 —
Bits 3-7 —
This value indicates what should happen upon a LAPM failure. These fallback options are
initiated immediately upon connection if S48=128. If an invalid number is entered, the number
is accepted into the register, but S36 will act as if the default value has been entered.
0=
Modem disconnects.
1=
Modem stays on-line and a Direct mode connection is established.
2=
Reserved.
3=
Modem stays on-line and a Normal mode connection is established.
4=
An MNP connection is attempted and if it fails, the modem disconnects.
5=
An MNP connection is attempted and if it fails, a Direct mode connection is
established.
6=
Reserved.
7=
An MNP connection is attempted and if it fails, a Normal mode connection is
established. (Default.)
Reserved
4-14
883
AT Command Reference Manual
S37 - Desired Line Connection Speed
Default: 0
Bits 0-4 —
Bits 5-7 —
883
Desired line connection speed. This is interlinked with the Fn command. If an invalid number
is entered, the number is accepted into the register, but S37 will act as if the default value has
been entered.
0=
Attempt auto mode connection (F0). (Default)
1-3 =
Attempt to connect at 300 bps (F1).
4=
Reserved.
5=
Attempt to connect at V.22 1200 bps (F4).
6=
Attempt to connect at V.22 bis 2400 bps (F5).
7=
Attempt to connect at V.23 (F3).
8=
Attempt to connect at V.32 bis/V.32 4800 bps (F6).
9=
Attempt to connect at V.32 bis/V.32 9600 bps (F8).
10 =
Attempt to connect at V.32 bis 12000 bps (F9).
11 =
Attempt to connect at V.32 bis 14400 bps (F10).
12 =
Attempt to connect at V.32 bis 7200 bps (F7).
Reserved
4-15
AT Command Reference Manual
S38 - Delay Before Forced Hang Up
This register specifies the delay between the modem's receipt of the H command to d isconnect (or ON-to-OFF transition of
DTR if the modem is programmed to follow the signal), and the disconnect operation. Applicable to error-correction
connection only. This register can be used to ensure that data in the modem buffer is sent before the m odem disconnects.
1.
If S38 is set to a value between 0 and 254, the modem will wait that number of seconds for the remote modem to
acknowledge all data in the modem buffer before disconnecting. If time expires before all data is sent, the NO
CARRIER result code will be issued to indicate that data has been lost. If all data is transmitted prior to time-out, the
response to the H0 command will be OK.
2.
If S38 is set to 255, the modem does not time-out and continues to attempt to deliver data in the buffer until the
connection is lost or the data is delivered.
Range:
0-255 seconds
Default: 20
S39 - Flow Control Bit Mapped Options Status
Default: 3 (00000011b)
Bits 0-2 —
Bits 3-7 —
Status of command options
0=
No flow control
3=
RTS/CTS (&K3) (Default.)
4=
XON/XOFF (&K4)
5=
Transparent XON (&K5)
6=
Both methods (&K6)
Reserved
4-16
883
AT Command Reference Manual
S40 - General Bit Mapped Options Status
Indicates the status of command options.
Default: 105 (69h) (01101001b)
Bit 0 - 1—
Bit 2—
Bits 3-5 —
Bits 6-7 —
883
MNP Extended Services (-Kn)
0=
Disable extended services (-K0) (Default for non-MNP 10 models.)
1=
Enable extended services (-K1) (Default for MNP 10 models.)
2=
Enable extended services (-K2)
Power Level Adjustment for Cellular Use ()Mn) (see S201 bit 6)
0=
Disable power level adjustment ()M0) (Default.)
1=
Enable power level adjustment ()M1 or )M2)
Break Handling (\Kn)
0=
\K0
1=
\K1
2=
\K2
3=
\K3
4=
\K4
5=
\K5 (Default.)
MNP block size (\An)
0=
64 chars (\A0)
1=
128 chars (\A1) (Default.)
2=
192 chars (\A2)
3=
256 chars (\A3)
4-17
AT Command Reference Manual
S41 - General Bit Mapped Options Status
Indicates the status of command options.
Default: 131 (10000011b)
Bits 0 -1 —
Bit 2, 6—
Compression selection (%Cn)
0=
Disabled (%C0)
1=
MNP 5 (%C1)
2=
V.42 bis (%C2)
3=
MNP 5 and V.42 bis (%C3) (Default.)
Auto retrain and fallback/fall forward (%En)
Bit 6
Bit 2
0
0 =
Retrain and fallback/fall forward disabled (%E0) (Default.)
0
1 =
Retrain enabled (%E1)
1
0 =
Fallback/fall forward enabled (%E2)
Bit 3 —
Reserved
Bits 4-5 —
Reserved
Bit 7 —
Enable fallback to V.22 bis/V.22 (-Qn)
0=
Disabled (-Q0)
1=
Enabled (-Q1) (Default.)
S46 - Data Compression Control
Controls selection of compression. The following actions are executed for the given values:
Range:
136 or 138
Default: 138
S46=136
Execute error correction protocol with no compression.
S46=138
Execute error correction protocol with compression. (Default.)
S48 - V.42 Negotiation Action
The V.42 negotiation process determines the capabilities of the remote modem. However, when the capabilities of th e
remote modem are known and negotiation is unnecessary, this process can be bypassed if so desired.
Range:
0, 7, or 128 If an invalid number is entered, it is accepted into the S-Register, but S48 will act as if 128
has been entered.
Default: 7
S48=0
Disable negotiation; bypass the detection and negotiation phases; and proceed with LAPM.
S48=7
Enable negotiation. (Default.)
S48=128
Disable negotiation; bypass the detection and negotiation phases; and proceed at once with
the fallback action specified in S36. Can be used to force MNP.
4-18
883
AT Command Reference Manual
S82 - Break Handling Options
S82 is for compatibility purposes only, changing this register will not have any affect.
S86 - Call Failure Reason Code
When the modem issues a NO CARRIER result code, a value is written to this S-Register to help determine the reason for
the failed connection. S86 records the first event that contributes to a NO CARRIER message. The cause codes are:
Range:
0, 4, 5, 9, 12, 13, or 14
Default:
S86=0
Normal disconnect, no error occurred.
S86=4
Loss of carrier.
S86=5
V.42 negotiation failed to detect an error-correction modem at the other end.
S86=9
The modems could not find a common protocol.
S86=12
Normal disconnect initiated by the remote modem.
S86=13
Remote modem does not respond after 10 re-transmissions of the same message.
S86=14
Protocol violation.
S91 - PSTN Transmit Attenuation Level
Sets the transmit attenuation level from 0 to 15 dBm for the PSTN mode, resulting in a transmit level from 0 to -15 dBm, In
some countries, the transmit level may not be changed and there are checks to prevent transmit attenuation level change
using ConfigurACE.
Range:
0 to 15 dBm (Corresponding to 0 to -15 dBm transmit level.)
Default: 10 (-10 dBm transmit level.)
S92 - Fax Transmit Attenuation Level
Sets the transmit attenuation level from 0 to 15 dBm for the fax mode, resulting in a transmit level from 0 to -15 dBm. In
some countries, the transmit level may not be changed and there are checks to prevent transmit attenuation level change
using ConfigurACE.
Range:
0 to 15 dBm (Corresponding to 0 to -15 dBm transmit level.)
Default: 10 (-10 dBm transmit level.)
883
4-19
AT Command Reference Manual
S95 - Extended Result Codes
The bits in this register can be set to override some of the Wn command options. A bit set to a 1 in this register will enable
the corresponding result code regardless of the Wn setting. Also, refer to Table 3 -1.
Default: 0
Bit 0 —
CONNECT result code indicates DCE speed instead of DTE speed.
Bit 1 —
Append/ARQ to CONNECT XXXX result code in error-correction mode (XXXX = rate; see
Table 3–1).
Bit 2 —
Enable CARRIER XXXX result code (XXXX = rate; see Table 3-1).
Bit 3 —
Enable PROTOCOL XXXX result code (XXXX = protocol identifier; see Table 3-1).
Bit 4 —
Reserved.
Bit 5 —
Enable COMPRESSION result code (XXXX = compression type; see Table 3-1).
Bit 6 —
Reserved.
Bit 7 —
Reserved.
S201 - Cellular Transmit Level
The bits in this register are set by the @Mn and :En commands to support cellular connections.
Default: 20h
Bits 0 - 4 —
Initial Cellular Power Level Setting (@Mn; default = @M0)
Bit 5 —
Compromise Equalizer Enable Command (:En; default = E1)
Bit 6 —
Lock Power Level Adjustment for Cellular Use ()Mn) (see S40 bit 2)
Bit 7 —
0=
Auto power level adjustment ()M0 or )M1) (Default.)
1=
Lock power level adjustment ()M2)
Reserved.
4-20
883
AT Command Reference Manual
A.
A.1.
BASIC AT COMMANDS
Command
A/
A
B0
B1
C1
Dn
E0
E1
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
H0
H1
I0
I1
I2
I3
I4
I5
I6
I7
L0
L1
L2
L3
M0
M1
M2
M3
N0
N1
O0
O1
P
Q0
Q1
Sn
Sn?
883
AT COMMAND SET SUMMARY
Function
Re-execute command.
Go off-hook and attempt to answer a call.
Select V.22 connection at 1200 bps.
Select Bell 212A connection at 1200 bps.
Return OK message.
Dial modifier.
Turn off command echo.
Turn on command echo.
Select auto-detect mode (equivalent to N1).
Select V.21 or Bell 103.
Reserved.
Select V.23 line modulation.
Select V.22 or Bell 212A 1200 bps line speed.
Select V.22 bis line modulation.
Select V.32 bis or V.32 4800 line modulation.
Select V.32 bis 7200 line modulation.
Select V.32 bis or V.32 9600 line modulation.
Select V.32 bis 12000 line modulation.
Select V.32 bis 14400 line modulation.
Initiate a hang-up sequence.
If on-hook, go off-hook and enter command mode.
Report product code.
Report pre-computed checksum.
Report OK.
Report firmware revision, model, and interface type.
Report response programmed by an OEM.
Report the country code parameter.
Report modem data pump model and code revision.
Reports the DAA code (W-class models only).
Set low speaker volume.
Set low speaker volume.
Set medium speaker volume.
Set high speaker volume.
Turn speaker off.
Turn speaker on during handshaking and turn speaker off while receiving carrier.
Turn speaker on during handshaking and while receiving carrier.
Turn speaker off during dialing and receiving carrier and turn speaker on during
answering.
Turn off automode detection.
Turn on automode detection.
Go on-line.
Go on-line and initiate a retrain sequence.
Force pulse dialing.
Allow result codes to DTE.
Inhibit result codes to DTE.
Select S-Register as default.
Return the value of S-Register n.
A-1
AT Command Reference Manual
=v
?
T
V0
V1
W0
W1
W2
X0
X1
X2
X3
X4
Y0
Y1
Z0
Z1
&C0
&C1
&D0
&D1
&D2
&D3
&F0
&F1
&G0
&G1
&G2
&J0
&J1
&K0
&K3
&K4
&K5
&K6
&L0
&L1
* Serial interface operation only.
Set default S-Register to value v.
Return the value of default S-Register.
Force DTMF dialing.
Report short form (terse) result codes.
Report long form (verbose) result codes.
Report DTE speed in EC mode.
Report line speed, EC protocol and DTE speed.
Report DCE speed in EC mode.
Report basic call progress result codes, i.e., OK, CONNECT, RING, NO CARRIER (also,
for busy, if enabled, and dial tone not detected), NO ANSWER and ERROR.
Report basic call progress result codes and connections speeds (OK, CONNECT,
RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO
ANSWER, CONNECT XXXX, and ERROR.
Report basic call progress result codes and connections speeds, i.e., OK, CONNECT,
RING, NO CARRIER (also, for busy, if enabled, and dial tone not detected), NO
ANSWER, CONNECT XXXX, and ERROR.
Report basic call progress result codes and connection rate, i.e., OK, CONNECT, RING,
NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, and ERROR.
Report all call progress result codes and connection rate, i.e., OK, CONNECT, RING,
NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, NO DIAL TONE and ERROR.
Disable long space disconnect before on-hook.
Enable long space disconnect before on-hook.
Restore stored profile 0 after warm reset.
Restore stored profile 1 after warm reset.
Force RLSD active regardless of the carrier state.
Allow RLSD to follow the carrier state.
Interpret DTR ON-to-OFF transition per &Qn:
&Q0, &Q5, &Q6
The modem ignores DTR.
&Q1, &Q4
The modem hangs up.
&Q2, &Q3
The modem hangs up.
Interpret DTR ON-to-OFF transition per &Qn:
&Q0, &Q1, &Q4,.
&Q5, &Q6
Asynchronous escape.
&Q2, &Q3
The modem hangs up.
Interpret DTR ON-to-OFF transition per &Qn:
&Q0 through &Q6
The modem hangs up.
Interpret DTR ON-to-OFF transition per &Qn:.
&Q0, &Q1, &Q4,.
&Q5, &Q6
The modem performs soft reset.
&Q2, &Q3
The modem hangs up.
Restore factory configuration 0.
Restore factory configuration 1.
Disable guard tone.
Disable guard tone.
Enable 1800 Hz guard tone.
Set S-Register response only for compatibility.
Set S-Register response only for compatibility.
Disable DTE/DCE flow control.
Enable RTS/CTS DTE/DCE flow control.
Enable XON/XOFF DTE/DCE flow control.
Enable transparent XON/XOFF flow control.
Enable both RTS/CTS and XON/XOFF flow control.
Select dial up line operation.
Select leased line operation.
A-2
883
AT Command Reference Manual
&M0
&M1
&M2
&M3
&P0
&P1
&P2
&P3
&Q0
&Q1
&Q2
&Q3
&Q4
&Q5
&Q6
&R0
&R1
&S0
&S1
&T0
&T1
&T2
&T3
&T4
&T5
&T6
&T7
&T8
&V
&W0
&W1
&X0
&X1
&X2
&Y0
&Y1
&Zn=x
%E0
%E1
%E2
%L
%Q
%TTn
Select direct asynchronous mode.
Select sync connect with async off-line command mode. *
Select sync connect with async off-line command mode and enable DTR dialing of
directory zero. *
Select sync connect with async off-line command mode and enable DTR to act as
Talk/Data switch. *
Set 10 pps pulse dial with 39%/61% make/break.
Set 10 pps pulse dial with 33%/67% make/break.
Set 20 pps pulse dial with 39%/61% make/break.
Set 20 pps pulse dial with 33%/67% make/break.
Select direct asynchronous mode.
Select sync connect with async off-line command mode. *
Select sync connect with async off-line command mode and enable DTR dialing of
directory zero. *
Select sync connect with async off-line command mode and enable DTR to act as
Talk/Data switch. *
Select Hayes AutoSync mode.
Modem negotiates an error corrected link.
Select asynchronous operation in normal mode.
CTS tracks RTS (async) or acts per V.25 (sync).
CTS is always active.
DSR is always active.
DSR acts per V.25.
Terminate any test in progress.
Initiate local analog loopback.
Returns ERROR result code.
Initiate local digital loopback.
Allow remote digital loopback.
Disallow remote digital loopback request.
Request an RDL without self-test.
Request an RDL with self-test.
Initiate local analog loop with self-test.
Display current configurations.
Store the active profile in NVRAM profile 0.
Store the active profile in NVRAM profile 1.
Select internal timing for the transmit clock.
Select external timing for the transmit clock.
Select slave receive timing for the transmit clock.
Recall stored profile 0 upon power up.
Recall stored profile 1 upon power up.
Store dial string x (to 35) to location n (0 to 3).
Disable line quality monitor and auto retrain.
Enable line quality monitor and auto retrain.
Enable line quality monitor and fallback/fall forward.
Return received line signal level.
Report the line signal quality.
PTT certification test signals.
* Serial interface operation only.
883
A-3
AT Command Reference Manual
\Kn
Controls break handling during three states:
When modem receives a break from the DTE:
\K0,2,4
Enter on-line command mode, no break sent to the remote modem.
\K1
Clear buffers and send break to remote modem.
\K3
Send break to remote modem immediately.
\K5
Send break to remote modem in sequence with transmitted data.
When modem receives \B in on-line command state:
\K0,1
Clear buffers and send break to remote modem.
\K2,3
Send break to remote modem immediately.
\K4,5
Send break to remote modem in sequence with transmitted data.
When modem receives break from the remote modem:
\K0,1
Clear data buffers and send break to DTE.
\K2,3
Send a break immediately to DTE.
\K4,5
Send a break with received data to the DTE.
\N0
Select normal speed buffered mode.
\N1
Select direct mode.
\N2
Select reliable link mode.
\N3
Select auto reliable mode.
\N4
Force LAPM mode.
\N5
Force MNP mode.
A.2.
+H0
+H1
+H2
+H3
Disable RPI.
Enable RPI and set DTE speed to 19200 bps.
Enable RPI and set DTE speed to 38400 bps.
Enable RPI and set DTE speed to 57600 bps.
**0
**1
**2
Download to flash memory at last sensed speed.
Download to flash memory at 38.4 kbps.
Download to flash memory at 57.6 kbps.
-SDR=0
-SDR=1
-SDR=2
-SDR=3
-SDR=4
-SDR=5
-SDR=6
-SDR=7
Disable Distinctive Ring.
Enable Distinctive Ring Type 1.
Enable Distinctive Ring Type 2.
Enable Distinctive Ring Type 1 and 2.
Enable Distinctive Ring Type 3.
Enable Distinctive Ring Type 1 and 3.
Enable Distinctive Ring Type 2 and 3.
Enable Distinctive Ring Type 1, 2, and 3.
ECC COMMANDS
%C0
%C1
%C2
%C3
Disable data compression.
Enable MNP 5 data compression.
Enable V.42 bis data compression.
Enable both V.42 bis and MNP 5 compression.
\A0
\A1
\A2
\A3
\Bn
Set maximum block size in MNP to 64.
Set maximum block size in MNP to 128.
Set maximum block size in MNP to 192.
Set maximum block size in MNP to 256.
Send break of n x 100 ms.
A-4
883
AT Command Reference Manual
A.3.
A.9.
MNP 10 COMMANDS
)M0
)M1
)M2
Disable MNP 10 link negotiation power adjustment.
Enable MNP 10 link negotiation power adjustment.
Enable cellular mode without power level adjustment during MNP 10 link negotiation.
*H0
*H1
*H2
Select MNP 10 link negotiation at highest rate.
Select MNP 10 link negotiation at 1200 bps.
Select MNP 10 link negotiation at 4800 bps.
-K0
-K1
-K2
-Q0
-Q1
-SEC=0
-SEC=1,[<tx level>]
Disable MNP 10 extended services.
Enable MNP 10 extended services.
Enable MNP 10 extended services detection only.
Disable MNP 10 fallback to 2400 bps (V.22 bis)/1200 bps (V.22).
Enable MNP 10 fallback to 2400 bps (V.22 bis)/1200 bps (V.22).
Disable MNP10-EC.
Enable MNP10-EC and set transmit level <tx level> 0 to 30 (0 dBm to -30 dBm).
@M0
@M1
@M2
@M3 - @M10
@M11
@M12
.
.
.
@M30
Select initial transmit level of -26 dBm.
Select initial transmit level of -30 dBm.
Select initial transmit level of -10 dBm.
Select initial transmit level of -10 dBm.
Select initial transmit level of -11 dBm.
Select initial transmit level of -12 dBm.
:E0
:E1
Disable the compromise equalizer.
Enable the compromise equalizer.
CELLULAR COMMANDS
^C2
^I
^T6
883
Select initial transmit level of -30 dBm.
Download cellular phone driver.
Identify cellular phone driver.
Indicate status of cellular phone.
A-5
AT Command Reference Manual
B.
COMMON CONFIGURATION SETUP STRINGS
This appendix describes setup strings to establish commonly used configurations.
1.
Force V.42 bis data compression with LAP-M error correction.
AT\N4%C2-K0
2.
Force V.42 bis data compression with MNP error correction.
AT\N5%C2
3.
Force MNP 5 data compression with MNP error correction.
AT\N5%C1
Note: With the setup strings in examples 1-3, if the remote is unable to negotiate the desire rate mode, the modem
will disconnect and respond with NO CARRIER.
4.
Auto negotiate data compression and error correction.
AT&F (factory defaults) or
AT\N3%C3
In this mode, the modem prefers LAP-M over MNP 10, MNP 10 over MNP 4, and V.42 bis over MNP 5. If error correction
is not negotiated, the modem will connect in normal mode.
….