Cres Cor H-135-UA-11-R Hot Cabinet Owner Manual
Cres Cor H-135 A Series is a hot cabinet designed to keep food warm and ready to serve. It features adjustable thermostat and thermometer for precise temperature control. The cabinet is made of durable materials for easy cleaning and maintenance and it is available in a variety of sizes and configurations to accommodate different needs. The H-135 A Series is ideal for use in restaurants, cafeterias, and other foodservice operations.
Advertisement
Advertisement
Hot Cabinets FL-2328
Rev. 5 (3/17)
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
H135UA11 & H135UA6 Hot Cabinets (Aluminum)
H135SUA11 & H135SUA6 Hot Cabinets (Stainless Steel)
Page 1 of 4
Model No.
H135UA6
H135UA11
H135SUA6
H135SUA11
Volts
120
Watts
1500
Amps
12.3
Hertz
60
Phase
1
NEMA
5-15P
H135UA6240
H135SUA6240
H135UA11240
H135SUA11240
240 1500 6.1
60 1 6-15P
All are designed for AC service. The above model numbers may be followed by “M”, “L”, “D”, “R” and ending with “S” or “Z”.
CONTROL PANEL PARTS IDENTIFICATION
1. Power Switch
2. Yellow Light-Power
3. Thermostat
4. Thermometer
HOW TO INSTALL UNIT:
1. Place cabinet near warm ovens. Do NOT put in drafty areas or near ventilating systems.
2. Plug cord end into proper wall outlet.
NOTE: No. 8 setting = approx. 190°F (88°C)
No. 6 setting = approx. 165°F (74°C)
Proper food holding temperature is 140°F (60°C) or higher. The thermometer shows the temperature inside.
HOW TO START UNIT:
1. Turn the POWER switch on. The yellow light will turn on.
2. Turn thermostat to #10.
3. Preheat cabinet for 30 minutes.
4. Put food into cabinet.
5. Turn thermostat to #8 and close door.
TO TURN OFF UNIT:
1. Turn thermostat off.
2. Turn the POWER switch off.
3. The yellow light will go out.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Hot Cabinets FL-2328
Rev. 5 (3/17) Page 2 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
H135UA11 & H135UA6 Hot Cabinets (Aluminum)
H135SUA11 & H135SUA6 Hot Cabinets (Stainless Steel)
MAINTENANCE
HOT UNIT REMOVAL INSTRUCTIONS
:
1. Unplug power cord from wall outlet.
2. Pull entire unit out the front of the cabinet.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
HOW TO CLEAN THE CABINET:
WARNING
BEFORE cleaning the cabinet:
1. Allow cabinet to cool.
2. Remove Hot unit from cabinet.
Cleaning Notes:
1. Wipe up spills as soon as possible.
2. Clean cabinet regularly to avoid heavy dirt build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer’s directions on cleaner.
5. Do not mix cleaners.
6. Avoid drips and splashes.
HOW TO CLEAN UNIT:
DOORS
Vinyl (Out)
Aluminum (In)
Soil
CABINETS
(H137UA11 and
H137UA6 are
Aluminum)
(H137SUA11 and
H137SUA6 are
Stainless Steel)
Dirt
Fingerprints, Grease and Oil
Water Spots
Cleaner Method
1. Wipe with soft, damp cloth.
2. Rinse well.
Mild detergent* and hot water, or mild abrasive cleaner.
Steam (No strong alkaline additive)
Chemical oven cleaner for cabinet material
Mild abrasive cleaner; oily or waxy cleaner
Mild abrasive cleaner.
Oily of waxy cleaner.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry.
Follow oven manufacturer’s directions
Apply with clean, soft cloth. Wipe with damp cloth.
Apply with soft, clean cloth.
Wipe with damp cloth.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Hot Cabinets FL-2328
Rev. 5 (3/17)
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
H135UA11 & H135UA6 Hot Cabinets (Aluminum)
H135SUA11 & H135SUA6 Hot Cabinets (Stainless Steel)
Page 3 of 4
TROUBLE-SHOOTING CHART:
FAILURE
1. Yellow light at switch does NOT light.
2. Unit does not heat.
3. Unit gets too hot or won’t shut off.
POSSIBLE CAUSE
1a. Circuit breaker/fuse to wall outlet is blown.
1b. Cord is unplugged from wall outlet.
1c. Switch is “OFF”.
2a. Thermostat set too low or is “OFF”.
2b. Switch is “OFF”.
3a. Defective electrical parts. UNPLUG UNIT FROM
WALL OUTLET.
4a. Defective blower.
4. Blower does not work or makes noise.
NOTE: Optional digital thermometer will flash if cabinet temperature is below 140° F or above 250° F.
Call the factory if you need different settings.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
REPLACEMENT PARTS:
DESCRIPTION
Hot Unit (H135UA11, H135UA6)
120 VOLT
HU-1254-058
Hot Unit (H135SUA11, H135SUA6) HU-1254-062
Blower Kit
Heater Kit
Thermostat Kit
Thermometer Kit (Analog)
Power Cord
Power Switch
Power Light
Terminal Block
CABINET
Door Assembly, Aluminum
Door Assembly, Red
Door Assembly, Stainless Steel
Door Gasket
Door Latch
Door Hinge
Pan Slides
0769-180-K
0811-019-K
0848-062-K
5238-030-K
0810-029
0808-116-K
0766-094
0852-091
W/BLACK FRAME
(PRIOR TO 2010)
1200-495-BL-K
1200-499-BL-K
-
0861-259-K
1006-154-01-K
0519-104-K
0621-281-K
240 VOLT
HU-1254-059
HU-1254-063
0769-182-K
0811-020-K
0848-062-K
5238-030-K
0810-039
0808-116-K
0766-095
0852-091
W/O BLACK FRAME
(2010-PRESENT)
1221-571-K
1221-571-RK
1221-571-SS
0861-271-K
1006-154-01-K
0519-104-K
0621-281-K
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Hot Cabinets FL-2328
Rev. 5 (3/17) Page 4 of 4
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
H135UA11 & H135UA6 Hot Cabinets (Aluminum)
H135SUA11 & H135SUA6 Hot Cabinets (Stainless Steel)
WIRING DIAGRAM:
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com