advertisement
▼
Scroll to page 2
of 6
Dew point DP 500/DP 510 Portable dew point meters with data logger The new instruments DP 500/DP510 are the Ideal for measurement of the current dew The data can be evaluated comfortably ideal portable service instruments for dew point and for graphic indication of the dew by means of the software CS Soft Basic. point measurement for all types of driers point curve/the switching behavior of the Measured data and service reports can be down to -80°Ctd dew point. drier over a longer period of time. issued easily and quickly. The 3.5" graphic display with touch screen Up to 100 million measured values can be DP 510 additionally disposes of one further makes the operation very easy. stored with date and measuring site name. freely assignable sensor input. The graphic indication of colored measuring curves is unique. The measured data can be transferred to the computer via USB stick. Apart from the internal dew point measurement one further optional sensor can be connected like for example: Pressure sensors Flow sensors, VA 400/420 Temperature sensors Pt 100, 4..20 mA Further dew point sensors Effective power meters Optional third-party sensors with the following signals: 0...1/10 V, 0/4...20 mA, Pt100, Pt1000, pulse, Modbus Special features: Precise dew point measurement down to -80°Ctd. Quick response time 3.5" graphic display / easy operation via touch screen Integrated data logger for storage of the measured values USB interface for reading out via USB stick Calculates all necessary moisture parameters like g/m³, mg/m³, ppm V/V, g/kg, °Ctdatm Pressure sensor 2nd freely assignable sensor input for third-party sensors (only DP 510) International: Up to 8 languages selectable Application ranges: Compressed air: Examination of refrigeration, membrane, adsorption driers Technical gases: Residual moisture meas. in gases like N2, O2 and so on Plastics industry: Examination of 2nd freely assignable sensor input for for third-party sensors (only DP 510) 26 www.cs-instruments.com granulate driers Medical compressed air/breathing air Dew point Everything at a glance Measurement curves are indicated graphically and thus the user can see at a glance the behaviour of the drier since the start of the measurement. Quick installation by means of measuring chamber All physical parameters of moisture measurement are calculated automatically. In case of DP 510 the measured values of the third-party sensor are indicated Ideal for service technicians everything in one case additionally. It is possible to store up to 100 million measured values. Each measurement can be stored with a comment, e. g. measuring site name. The time interval can be freely determined. Dry container - for sensor protection and quick adaptation time Technical data: Description Order No. Set DP 500 in a case - consisting of: Portable dew point meter DP 500 for compressed air and gases Mobile measuring chamber up to 16 bar Diffusion-tight PTFE hose with quick connector, length 1 m Power supply for DP 500/510 Control and calibration set 11.3 % RH Quick-lock coupling Dry container for CS dew point sensors Transportation case (small) for DP 500 Further options, not included in the set CS Soft Basic - data evaluation in graphic and table form reading out of the measured data of DP500/510 via USB Precision calibration at -40°Ctd with ISO certificate Additional calibr. point freely selectable in the range between -80…+20°Ctd High pressure measuring chamber up to 350 bar Measuring chamber for atmospheric dew point Measuring chamber for granulate driers with minimum overpressure Measuring chamber for respiratory air bottles up to 350 bar Portable dew point meter DP 500 for compressed air and gases (high pressure version up to 350 bar) 0600 0560 0699 0554 0554 0554 0530 0699 0554 Anwendungstechnische Merkmale der Verbrauchszähler VA 420: 0554 0699 0700 0699 0699 0699 0699 0500 0500 4490 0003 0009 0002 1101 2500 6500 7040 3396 7710 3590 3690 3490 3790 0560 0501 Display: 3.5" touch screen Measuring range: -80…+50°Ctd -20…+70°C 0…100 %RH Accuracy: ± 0,5°Ctd at -10…+50°Ctd typ. ± 2°Ctd remain. range Moistureparameters: g/m³, mg/m³, ppm V/V, g/kg, °Ctdatm, %RH Pressure range: -1…50 bar standard -1…350 bar special version Interface: USB interface Data logger: 2 GB SD memory card (100 million values) Power supply: Internal rechargeable Li-Ion batteries, approx 12 h continuous operation, 4 h charging time Screw-in thread: G1/2" stainless steel Surrounding temperature: 0…+50°C EMV: DIN EN 61326 Daten für ext. Fühler DP 510: Siehe Techn. Daten DS 400 Seite 50. www.cs-instruments.com 27 Dew point DP 500 / DP 510 Flexible data recording and transfer via USB cable or USB stick The stored measured data can be easily transferred to the computer via a USB stick or via a USB cable. The time periods are freely selectable or you just read out the whole memory. The data can be evaluated by means of the software CS Soft Basic in table and in graphic form. USB stick World debut photo key WORLD DEBUT Photo key stores curren t screen as image file. Ideal for documentation of the measured values/measurement curves on site. Coloured measurement curves can be sent by e-mail or integrated into a service report. By means of the photo key the "current screen" can be stored as an image file and printed out at the computer or edited without any additional software. In the past mini thermo transfer printers were used frequently. The lifetime of the printout is temporary and it cannot be used in the computer. Therefore the printout was glued onto a paper very often. 28 www.cs-instruments.com Dew point Data evaluation in 5 languages by means of CS Soft Basic Everything at a glance: Table, graph, statistics at the touch of a button the user gets all necessary information. Graphic evaluation All measurement curves are indicated in terms of colour. All necessary functions such as zoom, selection/deselection of single measurement curves, freely selectable time periods, scaling of the axis, selection of colours and so on are integrated: This view can be stored as a pdf file and sent by e-mail. Different data can be consolidated to a common file. Table view All measuring points are listed with exact time interval. The desired measuring channels with measuring site name can be selected via the diagram explorer. Statistics All necessary statistic data are visible at a glance. So the user can quickly see which minimum or maximum measured values occurred at which time and for how long. www.cs-instruments.com 29 Dew point Additionally to the internal dew point DP 510 measurement one further optional sensor can be connected. Portable dew point meter with data logger and third-party sensor So the user can meet nearly all industrial measuring tasks like for example: Performing measuring tasks with one instrument DP 510 disposes of all functions of Separate pressure measurement Dew point distance via external temperature sensor Compressed air consumption measurement DP 500 and has an additional freely Active power in kWh/kW assignable sensor input. Description Order No. Set DP 510 in a case - consisting of: Portable dew point meter DP 510 with one additional sensor input Mobile measuring chamber up to 16 bar Diffusion-tight PTFE hose with quick connector, length 1 m Power supply for DP 500/510 Control and calibration set 11.3 % RH Quick-lock coupling Dry container for CS dew point sensors Transportation case (big) for DP 510 as well as further sensors Further options, not included in the set Option for DP 510: "Mathematics calculation function" for 4 freely selectable channels, (virtual channels): addition, subtraction, division, multiplication Option for DP 510: "Totalizer function for analogue signals" CS Soft Basic - data evaluation in graphic and table form reading out of the measured data of DP500/510 via USB Precision calibration at -40°Ctd with ISO certificate Additional calibr. point freely selectable in the range between -80…+20°Ctd High preassure measuring chamber up to 350 bar Measuring chamber for atmospheric dew point Measuring chamber for granulate driers with minimum overpressure Measuring chamber for respiratory air bottles up to 350 bar Portable dew point meter DP 510 for compressed air and gases (high pressure version up to 350 bar) 0600 0560 0699 0554 0554 0554 0530 0699 0554 Anwendungstechnische Merkmale der Verbrauchszähler VA 420: Flow sensor VA 400 0510 0510 4490 0003 0009 0002 1101 2500 6510 Z500 5107 Z500 5106 0554 7040 0699 0700 0699 0699 0699 0699 0560 3396 7710 3590 3690 3490 3790 0512 Hinged current transformer Pressure sensor Clamp-on ammeter Dew point sensor FA 410 Third-party sensors 0-1/10 V (0) 4...20 mA Pulse Modbus/RS 485 Flow meter VA 420 Flow 30 Leakage Temperature probe Pt 100 Screw-in temperature probe Pt 1000 Dew point www.cs-instruments.com Pressure Current Temperature Current/effective power meter Dew point Suitable sensors for DP 510 ZSL 0120 ZSL 0160 ZSL 0300 ZSL 0400 engraved eingravierte depth Tiefenskala scale Locking ring Sicherungsring ddA == external AussenA diameter durchmesser x= dA 2 쑿 y 0695 1123 installation depth =Einbautiefe x+y =x+y 쑼 쑿 쑿 x Order No. 0695 1122 쑼 dA Flow sensors VA 400: VA 400 flow sensor, Max version (185 m/s), sensor length 220 mm, incl. 5 m connection cable to DP 510 VA 400 flow sensor, HighSpeed version (224 m/s), sensor length 220 mm, incl. 5 m connection cable to DP 510 Option for VA 400: sensor length 120 mm sensor length 160 mm sensor length 300 mm sensor length 400 mm 쑼 Flow measuring range VA 420 for compressed Flow meter VA 420 0.8... 90 l/min Flow meter VA 420 0.2... 90 m3/h Flow meter VA 420 0.3... 170 m3/h Flow meter VA 420 0.5... 290 m3/h Flow meter VA 420 0.7... 480 m3/h Flow meter VA 420 1.0... 550 m3/h Flow meter VA 420 2.0... 900 m3/h air (ISO 1217: 1000 mbar, 20°C) (R1/4” DN 8) (R1/2” DN 15) (R3/4” DN 20) (R1” DN 25) (R11/4” DN 32) (R11/2” DN 40) (R2” DN 50) 0695 0695 0695 0695 0695 0695 0695 0420 0421 0422 0423 0426 0424 0425 Flow Dew point sensor: FA 410 dew point sensor, -80...20°Ctd incl. mobile measuring chamber and 5 m connection cable to DP 510 0699 1411 Connection cable for VA/FA sensors: Connection cable for VA/FA series on mobile instruments, ODU / M12, 5 m 0553 0503 Calibration certificate for flow/dew point sensors: 5 point precision calibration for flow sensors incl. ISO certificate Precision calibration at -40°Ctd with ISO certificate 3200 0001 0699 3396 Pressure sensors: Order No. Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale 0694 1886 Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale 0694 0356 Dew point Pressure Temperature sensors: Bendable temperature probe, Pt100 Class B, length 300 mm, Ø3 mm, -70…+500°C, 0604 2 m probe connection cable glass fibre /stainless steel with ODU plug for mobile instruments Screw-in temperature sensor Pt 100, Class A, length 300 mm, Ø 6 mm, 0693 with measuring transducer 4...20 mA = 50...+500°C (2-wire technology) Temperature probe cable Pt 100, Class A, length 300 mm, Ø 6 mm, 0604 -50...+180°C, 5 m probe connection cable with open ends Miniature temperature probe cable Pt 100, Class A, length 25 mm, Ø 4 mm, 0604 -50...+180°C, 5 m connection cable Clamp screwing 6 mm, G1/2", VA clamping ring, pressure tight up to 10 bar 0554 Temperature calibration certificate, 2 calibration points 0520 0106 0002 0102 0105 6004 0180 onnection cables for pressure sensors/temperature sensors: Connection cable for pressure, temperature or external sensors on mobile instruments, ODU / open ends, 5 m 0553 0501 Connection cable for pressure,temperature or external sensors on mobile instruments, ODU / open ends, 10 m 0553 0502 Extension cable for mobile instruments,ODU / ODU, 10 m 0553 0504 Temperature Clamp-on ammeters: Clamp-on ammeter 0…400 A TRMS incl. 5 m connection cable 0554 0511 Clamp-on ammeter 0...1000 A TRMS incl. 5 m connection cable 0554 0508 Calibration certificate for clamp-on ammeter 0554 3333 Current/effective power meter up to 100 A 0554 5341 Current/effective power meter up to 600 A 0554 5342 - Mobile current/effective power meter with 3 external current transducers for big machines and plants - External current transformers for clamping on cables (100 or 600 A) - External magnetic measuring tips for measuring the voltage - Measures kW, kWh, cos phi, kVar, kVA - Data transfer to DP 510 via Modbus Connection cable for mobile current/effective power meter to DP 510, 5 m 0553 0506 Current Current Optional third-party sensors connectibel: e.g. heat meters, current meters, gas meters, water meters and so on. To the 2nd freely assignable sensor input all sensors of CS Instruments can be connected as well as optional third-party sensors and counters with the following signal outputs: 4-20 mA, 0-20 mA I 0-1 V / 0-10 V / 0-30 V I Pt100 (2- or 3-wire), Pt1000 (2- or 3-wire), KTY I pulse outputs (e.g. of gas counters) I Frequency output I Modbus protocol ? Third-party sensors www.cs-instruments.com 31
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project