Dew point
DP 500/DP 510
Portable dew point meters with data logger
The new instruments DP 500/DP510 are the
Ideal for measurement of the current dew
The data can be evaluated comfortably
ideal portable service instruments for dew
point and for graphic indication of the dew
by means of the software CS Soft Basic.
point measurement for all types of driers
point curve/the switching behavior of the
Measured data and service reports can be
down to -80°Ctd dew point.
drier over a longer period of time.
issued easily and quickly.
The 3.5" graphic display with touch screen
Up to 100 million measured values can be
DP 510 additionally disposes of one further
makes the operation very easy.
stored with date and measuring site name.
freely assignable sensor input.
The graphic indication of colored measuring
curves is unique.
The measured data can be transferred to
the computer via USB stick.
Apart from the internal dew point measurement one further optional sensor can be
connected like for example:
Pressure sensors
Flow sensors, VA 400/420
Temperature sensors Pt 100, 4..20 mA
Further dew point sensors
Effective power meters
Optional third-party sensors with the
following signals: 0...1/10 V, 0/4...20 mA,
Pt100, Pt1000, pulse, Modbus
Special features:
Precise dew point measurement
down to -80°Ctd.
Quick response time
3.5" graphic display / easy operation
via touch screen
Integrated data logger for
storage of the measured values
USB interface for reading out
via USB stick
Calculates all necessary moisture
parameters like g/m³, mg/m³,
ppm V/V, g/kg, °Ctdatm
Pressure sensor
2nd freely assignable sensor input
for third-party sensors (only DP 510)
International: Up to 8 languages
selectable
Application ranges:
Compressed air: Examination of refrigeration, membrane, adsorption driers
Technical gases: Residual moisture
meas. in gases like N2, O2 and so on
Plastics industry: Examination of
2nd freely assignable sensor input for
for third-party sensors (only DP 510)
26
www.cs-instruments.com
granulate driers
Medical compressed air/breathing air
Dew point
Everything at a glance
Measurement curves are indicated
graphically and thus the user can see at
a glance the behaviour of the drier since
the start of the measurement.
Quick installation by
means of measuring
chamber
All physical parameters of moisture
measurement are calculated automatically.
In case of DP 510 the measured values
of the third-party sensor are indicated
Ideal for service technicians everything in one case
additionally.
It is possible to store up to 100 million
measured values.
Each measurement can be stored with a
comment, e. g. measuring site name.
The time interval can be freely determined.
Dry container - for sensor protection and
quick adaptation time
Technical data:
Description
Order No.
Set DP 500 in a case - consisting of:
Portable dew point meter DP 500 for compressed air and gases
Mobile measuring chamber up to 16 bar
Diffusion-tight PTFE hose with quick connector, length 1 m
Power supply for DP 500/510
Control and calibration set 11.3 % RH
Quick-lock coupling
Dry container for CS dew point sensors
Transportation case (small) for DP 500
Further options, not included in the set
CS Soft Basic - data evaluation in graphic and table form reading out of the measured data of DP500/510 via USB
Precision calibration at -40°Ctd with ISO certificate
Additional calibr. point freely selectable in the range between -80…+20°Ctd
High pressure measuring chamber up to 350 bar
Measuring chamber for atmospheric dew point
Measuring chamber for granulate driers with minimum overpressure
Measuring chamber for respiratory air bottles up to 350 bar
Portable dew point meter DP 500 for compressed air and gases
(high pressure version up to 350 bar)
0600
0560
0699
0554
0554
0554
0530
0699
0554
Anwendungstechnische Merkmale
der Verbrauchszähler VA 420:
0554
0699
0700
0699
0699
0699
0699
0500
0500
4490
0003
0009
0002
1101
2500
6500
7040
3396
7710
3590
3690
3490
3790
0560 0501
Display:
3.5" touch screen
Measuring
range:
-80…+50°Ctd
-20…+70°C
0…100 %RH
Accuracy:
± 0,5°Ctd at
-10…+50°Ctd
typ. ± 2°Ctd remain. range
Moistureparameters:
g/m³, mg/m³, ppm V/V,
g/kg, °Ctdatm, %RH
Pressure
range:
-1…50 bar standard
-1…350 bar special version
Interface:
USB interface
Data logger:
2 GB SD memory card
(100 million values)
Power supply: Internal rechargeable
Li-Ion batteries, approx
12 h continuous operation,
4 h charging time
Screw-in
thread:
G1/2" stainless steel
Surrounding
temperature:
0…+50°C
EMV:
DIN EN 61326
Daten für ext. Fühler DP 510:
Siehe Techn. Daten DS 400 Seite 50.
www.cs-instruments.com
27
Dew point
DP 500 / DP 510
Flexible data recording and transfer
via USB cable or USB stick
The stored measured data can be easily
transferred to the computer via a USB stick
or via a USB cable.
The time periods are freely selectable or
you just read out the whole memory.
The data can be evaluated by means of
the software CS Soft Basic in table and in
graphic form.
USB stick
World debut photo key
WORLD
DEBUT
Photo key
stores curren
t
screen as
image file.
Ideal for documentation of the measured values/measurement curves on site.
Coloured measurement curves can be sent
by e-mail or integrated into a service report.
By means of the photo key the "current
screen" can be stored as an image file and
printed out at the computer or edited without
any additional software.
In the past mini thermo transfer printers
were used frequently. The lifetime of the
printout is temporary and it cannot be used
in the computer. Therefore the printout was
glued onto a paper very often.
28
www.cs-instruments.com
Dew point
Data evaluation in 5 languages by means of CS Soft Basic
Everything at a glance: Table, graph, statistics at the touch of a button the user gets all necessary information.
Graphic evaluation
All measurement curves are indicated in
terms of colour. All necessary functions
such as zoom, selection/deselection of
single measurement curves, freely selectable time periods, scaling of the axis,
selection of colours and so on are integrated:
This view can be stored as a pdf file
and sent by e-mail. Different data can be
consolidated to a common file.
Table view
All measuring points are listed with exact
time interval. The desired measuring
channels with measuring site name can be
selected via the diagram explorer.
Statistics
All necessary statistic data are
visible at a glance.
So the user can quickly see which minimum
or maximum measured values occurred at
which time and for how long.
www.cs-instruments.com
29
Dew point
Additionally to the internal dew point
DP 510
measurement one further optional sensor
can be connected.
Portable dew point meter
with data logger and third-party sensor
So the user can meet nearly all industrial
measuring tasks like for example:
Performing measuring
tasks with one instrument
DP 510 disposes of all functions of
Separate pressure measurement
Dew point distance via external
temperature sensor
Compressed air consumption
measurement
DP 500 and has an additional freely
Active power in kWh/kW
assignable sensor input.
Description
Order No.
Set DP 510 in a case - consisting of:
Portable dew point meter DP 510 with one additional sensor input
Mobile measuring chamber up to 16 bar
Diffusion-tight PTFE hose with quick connector, length 1 m
Power supply for DP 500/510
Control and calibration set 11.3 % RH
Quick-lock coupling
Dry container for CS dew point sensors
Transportation case (big) for DP 510 as well as further sensors
Further options, not included in the set
Option for DP 510: "Mathematics calculation function" for 4 freely selectable
channels, (virtual channels): addition, subtraction, division, multiplication
Option for DP 510: "Totalizer function for analogue signals"
CS Soft Basic - data evaluation in graphic and table form reading out of the measured data of DP500/510 via USB
Precision calibration at -40°Ctd with ISO certificate
Additional calibr. point freely selectable in the range between -80…+20°Ctd
High preassure measuring chamber up to 350 bar
Measuring chamber for atmospheric dew point
Measuring chamber for granulate driers with minimum overpressure
Measuring chamber for respiratory air bottles up to 350 bar
Portable dew point meter DP 510 for compressed air and gases
(high pressure version up to 350 bar)
0600
0560
0699
0554
0554
0554
0530
0699
0554
Anwendungstechnische Merkmale
der Verbrauchszähler VA 420:
Flow sensor
VA 400
0510
0510
4490
0003
0009
0002
1101
2500
6510
Z500 5107
Z500 5106
0554 7040
0699
0700
0699
0699
0699
0699
0560
3396
7710
3590
3690
3490
3790
0512
Hinged current
transformer
Pressure sensor
Clamp-on
ammeter
Dew point
sensor
FA 410
Third-party
sensors 0-1/10 V
(0) 4...20 mA
Pulse
Modbus/RS 485
Flow meter
VA 420
Flow
30
Leakage
Temperature
probe Pt 100
Screw-in temperature probe
Pt 1000
Dew point
www.cs-instruments.com
Pressure
Current
Temperature
Current/effective
power meter
Dew point
Suitable sensors for DP 510
ZSL 0120
ZSL 0160
ZSL 0300
ZSL 0400
engraved
eingravierte
depth
Tiefenskala
scale
Locking ring
Sicherungsring
ddA == external
AussenA
diameter
durchmesser
x=
dA
2
쑿
y
0695 1123
installation depth
=Einbautiefe
x+y
=x+y
쑼
쑿
쑿
x
Order No.
0695 1122
쑼
dA
Flow sensors VA 400:
VA 400 flow sensor, Max version (185 m/s),
sensor length 220 mm, incl. 5 m connection cable to DP 510
VA 400 flow sensor, HighSpeed version (224 m/s),
sensor length 220 mm, incl. 5 m connection cable to DP 510
Option for VA 400:
sensor length 120 mm
sensor length 160 mm
sensor length 300 mm
sensor length 400 mm
쑼
Flow measuring range VA 420 for compressed
Flow meter VA 420
0.8... 90 l/min
Flow meter VA 420
0.2... 90 m3/h
Flow meter VA 420
0.3... 170 m3/h
Flow meter VA 420
0.5... 290 m3/h
Flow meter VA 420
0.7... 480 m3/h
Flow meter VA 420
1.0... 550 m3/h
Flow meter VA 420
2.0... 900 m3/h
air (ISO 1217: 1000 mbar, 20°C)
(R1/4” DN 8)
(R1/2” DN 15)
(R3/4” DN 20)
(R1” DN 25)
(R11/4” DN 32)
(R11/2” DN 40)
(R2” DN 50)
0695
0695
0695
0695
0695
0695
0695
0420
0421
0422
0423
0426
0424
0425
Flow
Dew point sensor:
FA 410 dew point sensor, -80...20°Ctd incl. mobile measuring chamber
and 5 m connection cable to DP 510
0699 1411
Connection cable for VA/FA sensors:
Connection cable for VA/FA series on mobile instruments, ODU / M12, 5 m
0553 0503
Calibration certificate for flow/dew point sensors:
5 point precision calibration for flow sensors incl. ISO certificate
Precision calibration at -40°Ctd with ISO certificate
3200 0001
0699 3396
Pressure sensors:
Order No.
Standard pressure sensor CS 16, 0...16 bar, ± 1 % accuracy of full scale
0694 1886
Standard pressure sensor CS 40, 0...40 bar, ± 1 % accuracy of full scale
0694 0356
Dew point
Pressure
Temperature sensors:
Bendable temperature probe, Pt100 Class B, length 300 mm, Ø3 mm, -70…+500°C, 0604
2 m probe connection cable glass fibre /stainless steel with ODU plug for mobile instruments
Screw-in temperature sensor Pt 100, Class A, length 300 mm, Ø 6 mm,
0693
with measuring transducer 4...20 mA = 50...+500°C (2-wire technology)
Temperature probe cable Pt 100, Class A, length 300 mm, Ø 6 mm,
0604
-50...+180°C, 5 m probe connection cable with open ends
Miniature temperature probe cable Pt 100, Class A, length 25 mm, Ø 4 mm,
0604
-50...+180°C, 5 m connection cable
Clamp screwing 6 mm, G1/2", VA clamping ring, pressure tight up to 10 bar
0554
Temperature calibration certificate, 2 calibration points
0520
0106
0002
0102
0105
6004
0180
onnection cables for pressure sensors/temperature sensors:
Connection cable for pressure, temperature or external sensors on mobile
instruments, ODU / open ends, 5 m
0553 0501
Connection cable for pressure,temperature or external sensors on mobile
instruments, ODU / open ends, 10 m
0553 0502
Extension cable for mobile instruments,ODU / ODU, 10 m
0553 0504
Temperature
Clamp-on ammeters:
Clamp-on ammeter 0…400 A TRMS incl. 5 m connection cable
0554 0511
Clamp-on ammeter 0...1000 A TRMS incl. 5 m connection cable
0554 0508
Calibration certificate for clamp-on ammeter
0554 3333
Current/effective power meter up to 100 A
0554 5341
Current/effective power meter up to 600 A
0554 5342
- Mobile current/effective power meter with 3 external current transducers
for big machines and plants
- External current transformers for clamping on cables (100 or 600 A)
- External magnetic measuring tips for measuring the voltage
- Measures kW, kWh, cos phi, kVar, kVA
- Data transfer to DP 510 via Modbus
Connection cable for mobile current/effective power meter to DP 510, 5 m
0553 0506
Current
Current
Optional third-party sensors connectibel:
e.g. heat meters, current meters, gas meters, water meters and so on.
To the 2nd freely assignable sensor input all sensors of CS Instruments can be connected
as well as optional third-party sensors and counters with the following signal outputs:
4-20 mA, 0-20 mA I 0-1 V / 0-10 V / 0-30 V I Pt100 (2- or 3-wire), Pt1000 (2- or 3-wire),
KTY I pulse outputs (e.g. of gas counters) I Frequency output I Modbus protocol
?
Third-party sensors
www.cs-instruments.com
31

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement