70 series speed area monitor
U s er Gui de
70 Series
Speed Area Monitor
Connections Table and Assembly
Contact
Color
Description
2
Wht/Grn
SPEED signal
3
Green
Boom Sense input (+12v = work)
1
4
5
Contact
Color
Description
9
Brown
+12v Speed Sensor
10
Green
GND for speed sensor
11
Yellow
ALARM 2 output
12
Gray
ALARM 1 output
6
7
8
Note: Boom Sense +12v supply MUST share the same ground as the console.
71 Speed Area Monitor
75-30010
Pro
Speed
3 pos. Deutsch Skt.
001-US
V1.11
CLR
70 Series
To Battery
Main Harness
45-05429
Power Cable
45-05268
Power Supply
P os
Color
A
Red
(+12V)
B
Black
Ground
Color
A
Brown
Function
(+V)
B
Wht/Grn
Signal
C
Green
Ground
SPEED
Boom Sense - GREEN
Alarm 2 - YEL LOW
Alarm 1 - GRAY
Function
Pos
Proximity
Sensor
16-40004
Functionality
Function
Key
Description
1. Power on
Pro
2. Power off
and
001-US
V1.12
The unit will power on and show the Info screen.
Software name and Version are displayed.
The unit will power off
The first line on display shows Speed (MPH)
3. Selection of working
screen
4. Master On
Second line is user selectable (Distance, Area, or Total Area)
or
Example:000
Shows Upper line Speed (MPH / KPH) and Lower line
Distance (FT / M)
Pro
US Units
Metric Units
7.5MPH
105.7FT
12.0KPH
32.2M
The Pro key will act as the master switch and when pressed the console will begin to accumulate
area and distance.
NOTES:The master switch must be off to enter into setup
An external switch can be connected to the green boom sense wire to signal to the console
to start accumulating.
www.teejet.com
U s er G uide
Program
Function
Display
Possible Actions
Access or Exit
Push
width
setup
Width Setup
Pro
Pro
for 3 seconds
to access Width setup
to modify the width value
Pro
Comments
Master must be off
Master must be off
to access Speed setup
Manual Calibration
to modify speed sensor calibration number
speed
setup
Speed Setup
Auto Calibration
CLR to access auto calibration
Mark off a known distance of 300ft / 100m
Pro
to Start auto calibration
Master must be off
When using the Auto calibration procedure it
is best to mark a course on a surface that best
matches real-time operations. For the best
results repeat the Auto calibration procedure
3 times and take an average. Each run should
produce a similar calibration number.
Drive the 300ft / 100m course
Pro
Pro
to End auto calibration
to Save calibration number
Alarms
Function
Display
Possible Actions
Pro
to access Alarm 1
to select alarm options (None, Distance, Speed,
or Area)
Alarm 1
Speed Distance Area
Alarm
1
Pro
to access Distance, Speed, or Area
to adjust alarm value of Distance, Speed, or
Area.
CLR
CLR
to clear alarm message during operation.
for 3 seconds to clear alarm value and
reset Alarm.
Pro
to access Alarm 2
to select alarm options (None, Distance, Speed,
or Area)
Alarm 2
Speed Distance Area
Alarm
2
Pro
to access Distance, Speed, or Area.
to adjust alarm value of Distance, Speed, or
Area.
CLR
CLR
to clear alarm message during operation.
for 3 seconds to clear alarm value and
reset Alarm.
TeeJet Technologies
1801 Business Park Drive
Springfield, Illinois 62703 USA
www.teejet.com
98-05072 R3 EN-US English
© TeeJet Technologies 2013
Comments
NO audible alarm.
Alarm 1 output (gray wire) is +12v when Alarm 1
is active.
During real-time operation the alarm value must
be exceeded for at least 3 consecutive seconds
to activate alarm.
Displayed Speed, Distance, or Area must be
cleared or reduced below Alarm value to reset
alarm.
Audible alarm.
Alarm 2 output (yellow wire) is +12v when
alarm 2 is active.
During real-time operation the alarm value
must be exceeded for at least 3 consecutive
seconds to activate alarm.
Displayed Speed, Distance, or Area must
be cleared or reduced below Alarm value to
disable alarm.
Was this manual useful for you? yes no