Compuware 5.0 Workbench Installation Guide
Reklama
Reklama
Compuware Workbench
Installation Guide
Release 5.0
Please direct questions about the Compuware Workbench or comments on this document to:
http://go.compuware.com
This document and the product referenced in it are subject to the following legends:
Copyright 2015 Compuware Corporation. All rights reserved. Unpublished rights reserved under the Copyright Laws of the United States.
U.S. GOVERNMENT RIGHTS-Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in Compuware Corporation license agreement and as provided in DFARS
227.7202-1(a) and 227.7202-3(a) (1995), DFARS 252.227-7013(c)(1)(ii) (OCT 1988), FAR 12.212(a)
(1995), FAR 52.227-19, or FAR 52.227-14 (ALT III), as applicable. Compuware Corporation.
This product contains confidential information and trade secrets of Compuware Corporation. Use, disclosure, or reproduction is prohibited without the prior express written permission of Compuware
Corporation. Access is limited to authorized users. Use of this product is subject to the terms and conditions of the user’s License Agreement with Compuware Corporation.
Abend-AID, Abend-AID/Common, Abend-AID for CICS, Abend-AID Fault Analytics, Code
Coverage/Eclipse, Compuware Shared Services, Compuware Workbench, Compuware Workbench
Server, DevEnterprise, DBA-Xpert for DB2, Enterprise Common Components, File-AID/Common
Components, File-AID Data Editor, File-AID Data Privacy, File-AID/Data Solutions, File-AID/Eclipse,
File-AID/EX, File-AID/IMS, File-AID/MVS, File-AID Rules Engine, File-AID Search/Update, Hiperstation,
Hiperstation/Eclipse, Host Communications Interface, Host Explorer, License Management System,
Strobe, iStrobe, Xpediter, Xpediter/Code Coverage, Xpediter/CICS, Xpediter/Eclipse, Xpediter/Xchange,
Xpediter/TSO and IMS are trademarks or registered trademarks of Compuware Corporation.
IBM, CICS, DB2, and MVS/ESA are trademarks or registered trademarks of International Business
Machines Corporation
®
.
CA Endevor and CA Endevor Software Change Manager are trademarks or registered trademarks of CA
Technologies
®
.
SlickEdit, Visual SlickEdit, Clipboard Inheritance, DIFFzilla, SmartPaste, Context Tagging, Slick-C, and
Code Quick | Think Slick are registered trademarks of SlickEdit™ Inc.
Adobe
®
Reader
®
is a trademark of Adobe Systems Incorporated in the United States and/or other countries.
All other company and product names are trademarks or registered trademarks of their respective owners.
Doc. CWCEIX5A
January 27, 2015
iii
Contents
Compuware Go Customer Support Website . . . . . . . . . . . . . . . . . . . . . . . . xvi
Contacting Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
Compuware z/OS Product Plug-ins to Eclipse . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Compuware Editor powered by SlickEdit®. . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Milestone I: Configure Enterprise Common Components (ECC) . . . . . . . 2-4
Milestone II: Installing and Configuring the z/OS Product Plug-ins . . . . . 2-5
Milestone III: Installing File-AID Data Privacy . . . . . . . . . . . . . . . . . . . . . . 2-8
Milestone IV: Configuring Xpediter/Eclipse . . . . . . . . . . . . . . . . . . . . . . . 2-10
iv
Compuware Workbench Installation Guide
Milestone V: Installing and Configuring Support for File-AID/Eclipse. . 2-11
Milestone VI: Activating Hiperstation/Eclipse . . . . . . . . . . . . . . . . . . . . 2-13
Milestone VII: Activating Code Coverage/Eclipse . . . . . . . . . . . . . . . . . . 2-14
Milestone VIII: Configuring CA-ENDEVOR . . . . . . . . . . . . . . . . . . . . . . 2-15
Milestone IX. Deploy the z/OS Product Plug-ins to End-users . . . . . . . . 2-16
Installing File-AID Data Privacy (Non-mainframe) . . . . . . . . . . . . . . . . . 2-17
Chapter 3. Communications to the Mainframe . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Maintenance Level Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Pre-installation Considerations for Mainframe Interface . . . . . . . . . . . . . 3-2
Connection to z/OS Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Overview of HCI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Install Enterprise Common Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Part 1: Install and Configure the Host Communication Interface (HCI). . . . . 3-6
Install and Identify the HCI and CSS Datasets . . . . . . . . . . . . . . . . . . . . . 3-6
Configure a New HCI Image Using the Host Communication Configuration
Procedure Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Step 1. Start the Host Communication Configuration Facility. . . . . . . . . 3-8
Step 2. Provide the SMPE.DATA DSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Step 3. Enter the Name of the Compuware Installer Table Library. . . . . . 3-9
Step 4. Create a New or Edit an Existing Profile . . . . . . . . . . . . . . . . . . . 3-10
Step 5. Specify Configuration Values for the Profile . . . . . . . . . . . . . . . . 3-11
Step 6. Generate the Datasets, PROCs, and JCL for this Profile . . . . . . . 3-18
Step 7. Submit the JCL to create the HCI Journals and SSAS Journals . . 3-21
Step 8. Copy the Generated STASK and SSAS PROCS to PROCLIB . . . . . 3-21
Step 9. Submit the HCI JCL to Start the HCI Subsystem. . . . . . . . . . . . . 3-23
Part 2: Using the TP Installation Verification Utility . . . . . . . . . . . . . . . . . . . 3-26
Chapter 4. Compuware Workbench Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Installing the Compuware Workbench Client and z/OS Product Plug-ins . . . 4-1
Compuware Workbench Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Install the Compuware Workbench Client . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Installing Additional z/OS Product Plug-ins . . . . . . . . . . . . . . . . . . . . . . . 4-3
Installing Compuware’s z/OS Product Plug-ins into Eclipse or IBM RDz. . . . . 4-3
System Administrator Installation Process Details: . . . . . . . . . . . . . . . . . . 4-4
Chapter 5. Compuware Workbench Configurations . . . . . . . . . . . . . . . . . . . . . . . 5-1
Overview of Configuration and Deployment. . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Step 1. HCI Connection and Configuring Hosts. . . . . . . . . . . . . . . . . . . . 5-1
Step 2. Configure Compuware Mainframe Product Plug-ins (only for the
Abend-AID, Fault Analytics, or iStrobe plug-in users). . . . . . . . . . . . . . . 5-2
Step 3. Database Connections (for Data Privacy plug-in users) . . . . . . . . 5-2
Step 1. Install the Compuware Workbench Server (CWS) . . . . . . . . . . . . . . . . 6-2
Step 3. Install the File-AID Rules Engine (FARE) on z/OS UNIX . . . . . . . . . . . 6-5
v
Step 5. Install File-AID/Common Components . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Step 6. Install Additional File-AID Mainframe Products as Needed. . . . . . . . . . 6-7
Chapter 7. File-AID Product Installations and Configurations . . . . . . . . . . . . . . . 7-1
Support of File-AID/Eclipse and File-AID Data Privacy . . . . . . . . . . . . . . . . . . . 7-1
Chapter 8. Xpediter/Eclipse Installation and Configuration . . . . . . . . . . . . . . . . . 8-1
Support for Debugging Batch, IMS and Stored Procedures . . . . . . . . . . . . . . . . 8-1
Support for Debugging CICS Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-5
Using the CSS TP Configuration File . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
Chapter 9. Implement the Shared Services Address Space (SSAS) . . . . . . . . . . . . 9-1
Chapter 10. Hiperstation/Eclipse Installation and Configuration . . . . . . . . . . . . 10-1
Chapter 11. Code Coverage/Eclipse Installation and Configuration . . . . . . . . . 11-1
Requirements for Supporting Code Coverage/Eclipse . . . . . . . . . . . . . . . . . . . 11-1
Compuware Workbench Deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-1
Step 1: Export Configuration Settings to Central Preferences Directory . 12-1
Step 2. Establish Default Update Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-2
Host Explorer 5.0/CSS TP — Usage Restrictions. . . . . . . . . . . . . . . . . . . . . . . . A-1
Security Considerations for Using the JES Explorer View . . . . . . . . . . . . . . . . .B-1
Option 1: Limit user’s ability to view output using a security product.. . .B-1
Using Conditional Access for Canceling Jobs or Purging Output via JES
Defining a Console to RACF to use Conditional Access . . . . . . . . . . .B-4
Controlling User Ability to View SYSLOG from JES Explorer. . . . . . . . . . .B-5
Controlling User Ability to Issue System Commands . . . . . . . . . . . . . . . .B-6
CXSS0000 Started-task Procedure Security Considerations . . . . . . . . . . . . . . . .B-8
Controlling User Access to the CSS TP's Compuware Workbench Connection
vi
Compuware Workbench Installation Guide
Defining Application Access to your Security Software . . . . . . . . . . . . . . B-9
JES Explorer Security Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . B-11
Migration Considerations for Compuware Workbench 5.0. . . . . . . . . . . . . . . C-1
Exporting Compuware Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Workspace Handling Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Upgrade Compuware Workbench . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
Upgrading within an Eclipse-based Environment . . . . . . . . . . . . . . . C-3
Importing Compuware Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3
Migration Considerations for HCI and the CSS TP . . . . . . . . . . . . . . . . . . . . . C-3
Migration Considerations for File-AID/Eclipse 5.0 . . . . . . . . . . . . . . . . . . . . . . C-4
Migration Considerations for Xpediter/Eclipse 5.0 . . . . . . . . . . . . . . . . . . . . . C-5
Compuware Workbench Server and Client Compatibility . . . . . . . . . . . . . . . C-6
Migrating Compuware Mainframe Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6
Importing Compuware Mainframe Projects from Previous Releases . . . . C-6
Importing Non-Compuware Projects from Previous Releases. . . . . . . . . . C-6
Appendix D. Applying Compuware Workbench Cumulative Maintenance . . . . . D-1
Set Available Software Site for Compuware Workbench . . . . . . . . . . . . . . . . . D-1
Applying Updates to z/OS Product Plug-ins . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
Adding Optional or Additional z/OS Product Plug-ins . . . . . . . . . . . . . . . D-2
Applying Maintenance to the Compuware Workbench Server . . . . . . . . . . . . D-3
Maintaining Compuware Workbench Server . . . . . . . . . . . . . . . . . . . . . . D-3
Maintaining the File-AID Rules Engine (FARE). . . . . . . . . . . . . . . . . . . . . . . . . D-4
Uninstalling Compuware Workbench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-4
Uninstalling the Compuware Workbench Server. . . . . . . . . . . . . . . . . . . . . . . D-5
Appendix E. Compuware Workbench Server Ancillary Procedures . . . . . . . . . . . . E-1
Changing Compuware Workbench Server Port Assignments . . . . . . . . . . . . . E-1
Executing the Server Configuration Utility. . . . . . . . . . . . . . . . . . . . . . . . E-1
Adding Compuware Workbench Server Database Drivers . . . . . . . . . . . . . . . . E-2
Executing the Server Configuration Utility. . . . . . . . . . . . . . . . . . . . . . . . E-2
Adding File-AID Rules Engine Database Drivers . . . . . . . . . . . . . . . . . . . . . . . E-2
Install the Compuware Workbench Server to Linux . . . . . . . . . . . . . . . . . . . . E-3
Controlling the Compuware Workbench Server in Linux . . . . . . . . . . . . . . . . E-4
Installing the File-AID Rules Engine for File-AID/EX on Unix/Linux . . . . . . . E-4
Create and Manage the CSS TP Configuration Member . . . . . . . . . . . . . . . . . .F-1
Customize the CSS TP Configuration Member . . . . . . . . . . . . . . . . . . . . . .F-1
Code the LOCAL Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-2
Code the HCI Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-3
Code the CICS Statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-4
Code the TSO Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-5
Code the APPL Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-6
Code the CSPF Statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-6
Code the JES3 Statement (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . .F-7
Code the DSNHLQ Statement (Optional) . . . . . . . . . . . . . . . . . . . . . .F-7
Code the ENABLE Statement (Optional) . . . . . . . . . . . . . . . . . . . . . . .F-8
Code the STASK Statement (Optional). . . . . . . . . . . . . . . . . . . . . . . . .F-9
Code the SSAS Statement (Optional) . . . . . . . . . . . . . . . . . . . . . . . . .F-10
vii
Code the JOURNAL Statement (Optional) . . . . . . . . . . . . . . . . . . . . F-10
Code the HPERPLIB Statement (Optional) . . . . . . . . . . . . . . . . . . . . F-11
Code the AUDIT Statement (Optional) . . . . . . . . . . . . . . . . . . . . . . . F-11
Code the SYSOUT Statement (Optional). . . . . . . . . . . . . . . . . . . . . . F-12
Code the INACTIVITY Statement (Optional) . . . . . . . . . . . . . . . . . . F-13
Code the CONSOLEPOE Statement (optional) . . . . . . . . . . . . . . . . . F-13
Code the APPLICATION Statement (Optional). . . . . . . . . . . . . . . . . F-14
Code the SYSCMD Statement (Optional) . . . . . . . . . . . . . . . . . . . . . F-15
Code the SYSLOG Statement (Optional). . . . . . . . . . . . . . . . . . . . . . F-17
Code the OIDCARD Statement (Optional) . . . . . . . . . . . . . . . . . . . . F-19
Code the EXCLUDE Statement (Optional) . . . . . . . . . . . . . . . . . . . . F-19
Code the CREDENTIALS Statement (Optional) . . . . . . . . . . . . . . . . F-20
Code the NOTIFY Statement (Optional) . . . . . . . . . . . . . . . . . . . . . . F-21
Code the NOTIFYONLY Statement (Optional) . . . . . . . . . . . . . . . . . F-22
Code the CXTPMSGS Statement (Optional) . . . . . . . . . . . . . . . . . . . F-23
Code the UNITNAME Statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . F-24
Code the READTIMEOUT Statement . . . . . . . . . . . . . . . . . . . . . . . . F-25
Checking for Message Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-26
Approach 1 — Configuring an Existing HCI Image using HCIXML . . . . G-1
Step 1. Convert macros to XML . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-1
Step 3. Add the HCI parmlib member for the CSS TP and customize the
Approach 2 — Continue to use the HCI Configuration Macro Assembly
Step 1. Convert XML to macros . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-2
Step 2. (Optional) Convert to HCI 3.0 . . . . . . . . . . . . . . . . . . . . . . . G-3
Appendix H. Compuware Maintenance Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . H-1
Appendix I. Compuware Workbench Messages and Codes . . . . . . . . . . . . . . . . . . I-1
viii
Compuware Workbench Installation Guide
ix
Tables
x
Compuware Workbench Installation Guide
xi
Figures
Relationship of Configuration Specifications for the HCI and TP ..........................3-5
Compuware Installer Customization dialog library screen ...................................3-10
Profile Management — HC01 Profile created - G to Generate JCL........................3-19
Confirming HCI Parmlib and CSS TP Configuration DSNs...................................3-20
CXSS0000 sample CSS TP start-up STASK procedure (member xxxxCXSS) ..........3-22
Sample JCL in the Generated Members PDS xxxx$004 member ..........................3-26
Example messages from an established HCI connection.......................................3-27
Example job log messages from CXTPIVP utility execution..................................3-27
File-AID Data Privacy Installation and Configuration.............................................6-1
RDO Program Definition for Compuware Workbench Sockets Security Exit XPD-
Coding the SYSOUT statement within the TP Configuration File member ............B-3
xii
Compuware Workbench Installation Guide
Summary report without a PRODUCTS DD control file......................................... H-4
xiii
Introduction
This manual contains instructions for installing, customizing, and maintaining the
Compuware Workbench solution.
Compuware Workbench contains a branded Eclipse Rich Client Platform (Compuware
Workbench client) and a set of standard z/OS Product Plug-ins to Compuware’s mainframe productsCompuware Workbench.
Intro
In addition, Compuware Workbench contains Host Services communication facilities and infrastructure technology required to support the following Compuware plug-ins:
z/OS Product Plug-ins
• Host Explorer
• Code Coverage/Eclipse
• Compuware Editor powered by SlickEdit™
• File-AID/Eclipse
• Hiperstation/Eclipse
• Xpediter/Eclipse
• Abend-AID plug-in
1
• iStrobe plug-in
• Fault Analytics plug-in
• File-AID Data Privacy
Compuware recommends using either a Compuware-supported version of Eclipse or
IBM RDz when third-party plug-ins are to be installed alongside Compuware
Workbench plug-ins. Installing third-party plug-ins along with z/OS ProductPlug-ins into Compuware Workbench may encounter unexpected results. Any reported problems with z/OS ProductPlug-ins must be reproducible in an installation of
Compuware Workbench not containing any third-party plug-ins.
Manual Structure
This Compuware Workbench Installation Guide is composed of the following chapters:
Chapter 1, “Overview”: This chapter provides overview information for each of its
features, and provides installation considerations and requirements.
Chapter 2, “Installation Preparation and Checklist”: This chapter provides planning
and preparation information an d a summary of the necessary steps to complete the installation and configuration of the software components required for Compuware
Workbench.
Chapter 3, “Communications to the Mainframe”: This chapter contains important
information that can help you install the mainframe software needed to support host communication for Compuware Workbench.
Chapter 4, “Compuware Workbench Installation”: This chapter explains the steps
required to install the client on your Windows workstation.
1. Abend-AID, iStrobe, and Fault Analytics plug-ins allow access to their respective base products’ browser interface, viewed a Web browser view within the Compuware Workbench client.
xiv
Compuware Workbench Installation Guide
Chapter 5, “Compuware Workbench Configurations”: This chapter contains
important information that can help you tailor and prepare to deploy Compuware
Workbench for your user community.
Chapter 6, “File-AID Data Privacy”: This chapter details the installation process and
requirements to install and use the File-AID Data Privacy plug-in.
Chapter 7, “File-AID Product Installations and Configurations”: This chapter contains
important information about tailoring the File-AID mainframe and distributed point products to work with Compuware Workbench.
Chapter 8, “Xpediter/Eclipse Installation and Configuration”: This chapter contains
important information about tailoring the Xpediter mainframe point products to work with Compuware Workbench.
Chapter 9, “Implement the Shared Services Address Space (SSAS)”: This chapter
contains information about Shared Services Address Space which is needed to support functions related to DDIO processing using the Host Explorer.
Chapter 10, “Hiperstation/Eclipse Installation and Configuration”: This chapter
contains important information about tailoring Hiperstation mainframe point product to work with Compuware Workbench.
Chapter 11, “Code Coverage/Eclipse Installation and Configuration”: This chapter
contains important information about tailoring the Xpediter/Code Coverage mainframe point product to work with Compuware Workbench.
Compuware Workbench
Chapter 12, “Deployment”: This chapter describes steps to enable end-users to easily
install and configure Compuware Workbench.
Appendix A, “Usage Restrictions”: This appendix explains the usage restriction for
Compuware Workbench.
Appendix B, “Security Considerations”: This appendix discusses security
considerations for Using the JES Explorer.
Appendix C, “Migrating from Previous Versions”: This appendix provides the basic
procedures for migrating configuration settings and preferences from prior releases of
Compuware Workbench plug-ins.
Appendix D, “Applying Compuware Workbench Cumulative Maintenance”: This
appendix provides information on applying maintenance to Compuware Workbench and
Compuware Workbench Server.
Appendix E, “Compuware Workbench Server Ancillary Procedures”: This appendix
includes ancillary processes and procedures related to the installation and configuration of the
Compuware Workbench Server.
Appendix F, “CSS TP Configuration Member”: The appendix discusses various aspects
of the CSS TP configuration member, which designates various types of information used by the mainframe components of Compuware Workbench software.
Appendix G, “Running a Single HCI to Support Compuware Workbench and
DevEnterprise”: The appendix discusses a couple of approaches for setting up to run a
single HCI instance for the specialized case of Compuware Workbench and
DevEnterprise.
Appendix H, “Compuware Maintenance Utility”: This appendix discusses the
maintenance utility program that provides a list of all of the Compuware PTFs applied to your system across product lines.Compuware WorkbenchCompuware Workbench
Introduction
xv
Appendix I, “Compuware Workbench Messages and Codes”: This appendix explains
the return and reason codes that can be issued by the communications interface during use of Compuware Workbench facilities.
Intended Audience
This manual is intended for installers and application programmers. It is primarily to be used for installing modernized interfaces for Compuware Mainframe products.
Related Publications
For more information about Compuware Shared Services (CSS), License Management
System (LMS), and Host Communication Interface (HCI) refer to the Compuware documentation shipped with the Enterprise Common Components (ECC) media or on
Compuware Go/Frontline.
For more information about Xpediter/TSO and IMS and Xpediter/CICS, refer to the documentation shipped with the Xpediter EP media or on Compuware Go/Frontline.
For more information about File-AID for DB2, File-AID/IMS, File-AID/MVS, File-AID/Data
Solutions, File-AID/RDX, and File-AID/EX refer to the documentation shipped with the
File-AID EP and Test Data Privacy EP media or on Compuware Go/FrontLine.
For more information about iStrobe, Strobe Abend-AID, Abend-AID Fault Analytics, refer to the documentation shipped with the Abend-AID and Strobe products or on
Compuware Go/Frontline.
For more information about Hiperstation, refer to the documentation shipped with the
Hiperstation media or on Compuware Go/FrontLine.
For more information on compiling COBOL, PL/I, Assembler, or C/C++ programs, refer to the appropriate IBM manuals.
Instructions for accessing this documentation are given in the following paragraphs.
FrontLine Support Web Site
Access online technical support for Compuware products through our Compuware
Go/FrontLine support web site. View or download documentation, frequently asked questions, and product fixes, or e-mail Compuware with questions or comments. To access Compuware Go/FrontLine, you must first register and obtain a password at
http://go.compuware.com
Online Documentation
Documentation for this product is provided in the following formats:
• PDF files: Portable Document Format (PDF) files are provided on the installation media and can be viewed with the free Adobe Reader, available at
http://www.adobe.com. If you encounter a problem opening a PDF, you may be using an unsupported version of the Adobe Reader. Access the Adobe web site and download the most current version.
• Eclipse Help: Accessing Help > Help Contents from Eclipse, IBM RDz or Compuware
Workbench provides access to detailed user guides for the installed Compuware
Workbench client and z/OS Product and z Innovation Plug-ins.
xvi
Compuware Workbench Installation Guide
Accessibility Information
Compuware is committed to making its products and services easier for everyone to use.
This section provides information about the features that make Compuware Workbench more accessible for people with disabilities.
Documentation Accessibility
Documentation is provided in PDF and other formats. The PDF documents provide the best accessibility because they are tagged to enable reflow and correct reading order.
Getting Help
Compuware provides a variety of support resources to make it easy for you to find the information you need.
Compuware Go Customer Support Website
You can access online information for Compuware products via our Compuware Go customer support website at http://go.compuware.com.
Compuware Go provides access to critical information about your Compuware products.
You can review frequently asked questions, read or download documentation, access product fixes, or e-mail your questions or comments. The first time you access
Compuware Go, you are required to register and obtain a password. Registration is free.
Compuware now offers User Communities, online forums to collaborate, network, and exchange best practices with other Compuware solution users worldwide. To join, go to
http://groups.compuware.com.
Contacting Customer Support
Phone
• USA and Canada: 1-800-538-7822 or 1-313-227-5444.
• All other countries: Contact your local Compuware office. Contact information is available at http://go.compuware.com.
Web
You can report issues via the Quick Link Create & View Support Cases on the
Compuware Go home page.
Note: Please report all high-priority issues by telephone.
Compuware Customer Support
Compuware Corporation
One Campus Martius
Detroit, MI 48226-5099
Corporate Website
To access Compuware’s site on the Web, go to http://www.compuware.com.
The Compuware site provides a variety of product and support information.
1-1
Chapter 1.
Overview
This chapter provides overview information, installation considerations and requirements for Compuware’s z/OS Product Plug-ins to Eclipse (z/OS Product Plug-ins).
This manual contains instructions for installing, customizing, and maintaining these plug-ins provided with the Compuware Workbench installation.
Compuware Workbench provides a graphical user interface (GUI) to Compuware's
mainframe products.
Compuware recommends using either a Compuware Workbench-supported version of Eclipse or IBM RDz environment when third-party plug-ins are to be installed along side Compuware’s z/OS Product Plug-ins. Installing third-party plug-ins
within the Compuware Workbench client may have unexpected results. Any reported
problems must be reproducible in an installation of the Compuware Workbench
client not containing third-party plug-ins.
Compuware z/OS Product Plug-ins to Eclipse
The Compuware Workbench client (or alternatively, an Eclipse or IBM RDz instance) provides the user interface for the Compuware z/OS Product Plug-ins. Compuware
Workbench includes the following z/OS Product Plug-ins:
Host Explorer
Host Explorer provides mainframe application developers a distributed platform alternative to a 3270 session, by allowing them to stay inside the GUI workstation environment for:
• Navigation of mainframe datasets, including z/OS UNIX files.
• Viewing, editing, or saving PDS members.
• Creation, viewing, and deleting of DDIO files, including the ability to view and delete DDIO members.
• Accessing and managing source in CA Endevor libraries.
• Submitting batch JOBs and using the JES Explorer to manage JES input/output queues.
• Supporting VSAM, sequential dataset and PDS/member functionality.
• Creating and maintaining preprocessor and postprocessor compile profiles.
• Searching for text in mainframe PDS and sequential files.
• (For File-AID for DB2) Navigating DB2 Subsystems to locate tables and views for
Browse/Edit.
• (For File-AID for IMS) Navigating IMS Environments to locate databases for
Browse/Edit.
Compuware Editor powered by SlickEdit®
Compuware Editor powered by SlickEdit
®
is a source code editor featuring:
1-2
Compuware Workbench Installation Guide
• Support for over 40 languages.
• Emulations for many popular editors including ISPF, Brief and Vim.
• Customizable support for in-house languages, including Syntax Expansions, Aliases,
Color Coding, Keyword Definitions, copybook handling, the DIFFzilla differencing engine.
• It uses the Outline and References views and offers the Slick-C macro language.
Xpediter/Eclipse
Xpediter/Eclipse works with Host Explorer to enable Xpediter/TSO and Xpediter/IMS, or
Xpediter/CICS users to edit and debug application programs and use mainframe-based compilers within the GUI workstation environment, rather than toggling to a 3270 session.
In addition to the functions provided by Host Explorer, Xpediter/Eclipse supports five types of debugging sessions via a launch configuration utility: Xpediter Batch, Xpediter
TSO, Xpediter IMS MPP, Xpediter DB2 Stored Procedure, and Xpediter for CICS. From this utility, users can create, delete, duplicate, or execute an instance of any of these types of launch configurations. Xpediter/Eclipse users can view their programs, step through execution one statement at a time, set a variety of breakpoints, view the current value of variables, and use other displays to guide their debugging efforts.
COBOL and PL/I program structure and logic flow from within a SlickEdit editing session.
File-
AID/Eclipse
File-AID/Eclipse works with Host Explorer to enable File-AID/MVS users to search, browse and edit z/OS VSAM and sequential datasets, as well as z/OS UNIX files; File-AID for IMS users to browse and edit IMS databases; and File-AID for DB2 users to browse and edit
DB2 tables and views within the GUI workstation environment without requiring a 3270 session. File-AID/Eclipse consists of the File-AID Data Editor plug-in, plus extra utility functions (for example: the File-AID Dataset Search/Update option of the Search menu).
File-AID Data Privacy
File-AID Data Privacy is used for defining disguise criteria for use in disguising personal identification information in distributed test data with File-AID/EX or mainframe test data with
File-AID z/OS products.
Hiperstation/Eclipse
Hiperstation/Eclipse enables Hiperstation users to perform application auditing within the GUI workstation environment without requiring a 3270 session. Results data is secure because users can only access results that they are authorized to read.
Code Coverage/Eclipse
Code Coverage/Eclipse is the modernized GUI for Compuware’s Xpediter/Code Coverage product. With it, users can create reports detailing testing efficiency and risk metrics for mainframe COBOL, PL/I, and High Level Assembler programs.
Abend-AID Access
The Abend-AID plug-in enables the Abend-AID Web Browser Interface to run in an
Eclipse-based IDE environment.
Overview
1-3
iStrobe Access
The iStrobe plug-in enables iStrobe to run in an Eclipse-based IDE environment. Support is also provided to establish Strobe measurement requests via the JES Explorer view.
Fault Analytics Access
The Fault Analytics plug-in enables Fault Analytics to run in an Eclipse-based IDE environment.
Companion Product Requirements
Compuware supports the Compuware z/OS Product Plug-ins installed into the
Compuware Workbench client, Eclipse or IBM RDz instance running in a supported
Windows environment. In addition, when using Compuware’s z/OS Product Plug-ins with your mainframe, some or all of the companion products may be required.
Note: Consult the Compuware Workbench Release Notes and Compuware's Support
Website (go.compuware.com) product's fixes and downloads page for the specific versions of the companion product requirements.
• Host Explorer is required to support communication between the z/OS Product Plugins and any z/OS mainframe host. Compuware Enterprise Common Components
(ECC) products are required on the LPAR including: License Management System
(LMS), Host Communication Interface (HCI) and Compuware Shared Services (CSS).
• Xpediter/Eclipse requires Xpediter/TSO and IMS and/or Xpediter/CICS in support of the Xpediter/Eclipse plug-in.
• File-AID/Eclipse (contains File-AID Data Editor and File-AID Search/Update option) is used for the search, global updates, browse and edit of z/OS files, and requires File-
AID/MVS, which must be licensed and installed on the mainframe LPAR(s).
– Browse/edit of DB2 tables and views requires File-AID for DB2 be licensed, installed and updated with all current maintenance on the mainframe LPAR(s) accessed by the interface.
– Browse/edit of IMS databases requires a license for and installation of File-AID for
IMS with latest PTFs applied.
(For File-AID mainframe products prior to the 10.1 release requires the addition of File-AID/Common Components)
• File-AID Data Privacy requires installation of the Compuware Workbench Server.
The Compuware Workbench Server must be installed on a centrally accessible
Windows or Linux server. See Chapter 6, “File-AID Data Privacy”.
– Distributed RDBMS data sources disguise executions (Oracle, Microsoft SQL Server,
IBM DB2 LUW, Sybase) requires File-AID/EX to be installed on the Windows workstation.
File-AID/EX installation in Windows automatically installs an Execution Server and a File-AID Rules Engine (FARE). For use with additional remote Windows or
UNIX servers, you may also install a remote Execution Server and a File-AID
Rules Engine on each platform needed. File-AID/EX may also require that File-
AID/EX Enterprise edition be installed and configured in z/OS to support certain advanced uses of Data Privacy projects.
– z/OS disguise execution requires z/OS Release 1.10 or higher, File-AID/Data
Solutions (and optionally: File-AID/RDX, File-AID for IMS and/or File-AID for
DB2).
Additional z/OS requirements for File-AID Data Privacy include File-AID/Data
Solutions and installation of the File-AID Rules Engine in z/OS UNIX.
1-4
Compuware Workbench Installation Guide
• Hiperstation/Eclipse requires Hiperstation to be licensed and installed on the mainframe LPARs accessed by the interface. Hiperstation is shipped with the
Hiperstation EP media (or RFN order).
• Code Coverage/Eclipse requires a valid license for Xpediter/Code Coverage and is used in conjunction with Xpediter/Eclipse.
• iStrobe interface plug-in requires
– iStrobe to support the iStrobe report interface and,
– Strobe in support of Add Active and Add Queued on the mainframe.
• Abend-AID interface plug-in requires
– Abend-AID in support of the Abend-AID Web Browser Interface
• Fault Analytics interface plug-in requires
– Abend-AID in support of Fault Analytics reporting facility option.
2-1
Chapter 2.
Installation Preparation and Checklist
This chapter provides a summary of the steps that must be performed to successfully complete the installation and configuration of the software components required to use the Compuware’s z/OS Product Plug-ins provided with the Compuware Workbench media. You should first review the referenced steps and then use this checklist to complete the installation.
Note: For non-mainframe users deploying Compuware Workbench exclusively for
distributed File-AID Data Privacy, please skip to the “Non-Mainframe Checklist” on page 2-17.
Some items in the Mainframe Checklist will refer you to specific sections within this manual. Be sure to only follow the instructions in those sections, then return immediately to this Checklist to continue with the installation.
Mainframe Checklist
Introduction
Use this mainframe checklist to install and configure z/OS Product Plug-ins. It is designed to guide you through each stage of the installation and to confirm and validate each step along the way. This checklist will help you to quickly get the z/OS Product Plug-ins communicating with your mainframe(s).
Once basic communication is established and confirmed, the checklist contains information to help you install and configure each of the z/OS Product Plug-ins you choose to implement at your site.
Note: If you do not have a mainframe and are planning to use Compuware Workbench only for setting up File-AID Data Privacy projects for distributed databases, follow
the instructions provided in the “Non-Mainframe Checklist” on page 2-17.
Goal
The goal of this checklist is to ensure that you can use the z/OS Product Plug-ins as a modernized interface to the mainframe.
Preparation
When setting up communications with the host, you will need a default userID with
Start, Stop, and Submit authority. The default userID must also have write access to communications journals you establish. It is a good idea to plan for having this userID ready during the installation process.
Compuware Workbench is distributed on media or by FTP with an RFN order. The
Compuware Workbench Server (CWS) is distributed via the File-AID and Test Data
Privacy EP media, the File-AID/EX and File-AID distributed components media downloaded from an RFN order, or via download from the Fixes/Download section of the
Compuware Workbench site on FrontLine. All other companion products are available through Receive From Network (RFN) download (default) or EP media (by request). RFN
2-2
Compuware Workbench Installation Guide
allows you to order and install individual products, whereas EP media contains all products of a particular family.
Scenario
The mainframe checklist sets the scenario of a first-time installation of the z/OS Product
Plug-ins accessing a specific z/OS LPAR. In this scenario, the z/OS Product Plug-ins are assumed to do some or all of the following:
• Browse or edit DB2, IMS, and browse, edit, and search/update z/OS datasets and z/OS
Unix using File-AID
• Debug COBOL or PL/I programs using Xpediter
• Design and Manage File-AID Data Privacy Dynamic Privacy Rules
• Interact with Compuware Abend-AID Web Browser interface
• Interact with Compuware Fault Analytics
• Interface with Compuware Strobe and iStrobe
• Work with Hiperstation Audits using Hiperstation/Eclipse z/OS Product Plug-ins will also be used to perform related programmer functions like
• Edit source code and JCL
• Submit batch jobs
• View JES output
Milestone Summary
REQUIRED for all Compuware z/OS Product Plug-ins:
• “Milestone I: Configure Enterprise Common Components (ECC)” — Verify
communication to selected mainframe port.
• “Milestone II: Installing and Configuring the z/OS Product Plug-ins” — Verify
host connection, navigation, source editing, job submission, job output review.
USER-DETERMINED Milestones
• “Milestone III: Installing File-AID Data Privacy”— Verify communication to
Compuware Workbench Server and File-AID/Data Solutions.
• “Milestone IV: Configuring Xpediter/Eclipse”— Prepare Xpediter/TSO for
interactive debugging of COBOL or PL/I batch, TSO, IMS, and Stored procedure programs. Prepare Xpediter/CICS for interactive debugging of CICS programs. Verify debugging session.
• “Milestone V: Installing and Configuring Support for File-AID/Eclipse” — Install
products and configure them to facilitate browse/edit of DB2 tables, IMS databases, z/OS UNIX, and z/OS datasets with the File-AID Data Editor plug-in. The File-AID
Search/Update plug-in for searching z/OS files will automatically be enabled by this support. Verify table browse in DB2 and/or dataset browse in z/OS catalog and/or IMS database browse.
• “Milestone VI: Activating Hiperstation/Eclipse” — Verify that the
Hiperstation/Eclipse plug-in is installed and communication is tested.
• “Milestone VII: Activating Code Coverage/Eclipse” — Verify that the
CodeCoverage/Eclipse plug-in is installed and communication is tested.
• “Milestone VIII: Configuring CA-ENDEVOR” — Validate that communication with
the CA-Endevor interface is active.
RECOMMENDED for all installations
• “Milestone IX. Deploy the z/OS Product Plug-ins to End-users” — Stage
configurations for end-users.
Installation Preparation and Checklist
2-3
Installation Roles
Specialized expertise is required for each step of the installation process. Typically, expertise requirements fall into these roles:
• z/OS Systems Programmer
• Windows/Network Administrator
• Data Privacy Administrator (for working with Data Privacy).
• Quality assurance (installation verification)
The following table outlines the Installation Checklist steps and the role expertise required for each step.
Table 2-1.
Installation Milestone Tasks by Role
Checklist Item
Milestone I — Host Communications
z/OS
Systems
Programmer
Network
Admin
X
Desktop
User
Quality
Assurance
X
Milestone II — Compuware Workbench Client Master
Installation
Milestone III — Data Privacy
X X
Compuware Workbench Server
File-AID/EX Client
X
X X
1
z/OS UNIX File-AID Rules Engine z/OS File-AID Products
Modify STASK PROC
X
X
X
Configure CWS and hosts in Client
Configuration Roles
X
X X
2
Milestone IV — Xpediter/Eclipse
Verify Privacy
X
X
X
Milestone V — File-AID Eclipse
Modify STASK PROC
X
X
X
Milestone VI — Hiperstation/Eclipse
Milestone VII — Code Coverage/Eclipse
Modify SSAS PROC
Milestone VIII — Configure CA-ENDEVOR
Milestone IX — Deployment
X
X
X X
3
X
X
1. File-AID/EX must be installed by each Data Privacy user working with distributed remote databases.
2. Configuration of Data Privacy roles is usually done by the Data Privacy Administrator expert user.
3. Individual users need to install their own copy of the z/OS Product Plug-ins by installing the Compuware Workbench client or installing the z/OS Product Plug-ins into their Eclipse or IBM RDz instance. They import master preferences staged by the
Network Administrator.
2-4
Compuware Workbench Installation Guide
Milestone I: Configure Enterprise Common Components (ECC)
Milestone I is required and covers the configuration of the Enterprise Common
Components (ECC). ECC includes License Management System (LMS), Host
Communications Interface (HCI), and Compuware Shared Services (CSS).
You will set up a dedicated HCI and configure the CSS Mainframe Transaction Program
(CSS TP) image to service communication requests to the LPAR. Communication will then be initiated and verified to the selected mainframe port.
Note: The z/OS Product Plug-ins can work with multiple LPARs. If you are planning to support communication to additional LPARs, you must configure the HCI and CSS
TP for each.
What you will need to complete this Milestone
• an allowance of 1 hour (estimate) provided that LMS, CSS, and HCI are already installed. If you still need to install LMS, CSS, and HCI (from the ECC media or RFN order), you should allow about 2 hours to complete this milestone, keeping in mind that subsequent customization may require another 2 to 4 hours.
• a z/OS systems programmer
• access to update PROCLIB
• the TCP/IP region name for this LPAR
• the host name (or IP address) and an open TCP/IP port number
• ability to APF authorize a dataset
• a default userID with Start, Stop, and Submit authority. The default userID must also have write access to communications journals you establish.
• the ECC EP media (or RFN distributions of HCI, CSS, and LMS) or knowledge of where ECC is installed on the LPAR
Procedure
1. Read “Installation Considerations” on page 3-1.
Read “Install Enterprise Common Components” on page 3-3.
Read “Install the Mainframe Interface TP” on page 3-3.
2. Be aware of the various security considerations detailed in Appendix B, “Security
3. Follow all the steps in “Part 1: Install and Configure the Host Communication
4. Follow all the steps in “Part 2: Using the TP Installation Verification Utility” on page
Milestone I: Complete — Review the TP Installation Verification Report produced by the
Verification Utility.
Installation Preparation and Checklist
2-5
Milestone II: Installing and Configuring the z/OS Product Plug-ins
Milestone II is required and covers the installation and configuration of the
Compuware Workbench client. It also covers the installation of the z/OS Product Plug-ins into an Eclipse or IBM RDz instance. It presumes that the HCI is running on each LPAR you plan to connect to. Verify host connection, navigation, source editing, job submission, job output review and the optional Abend-AID, Fault Analytics, and iStrobe interface plug-ins.
What you will need to complete this Milestone
• about 2 hours (estimate) to complete
• Compuware Workbench media
• Windows machine to install a master copy of Compuware Workbench
• System Administrator access to the Windows machine
• a Central File Share machine accessible by Compuware Workbench users (can be the same machine as used for the master Compuware Workbench installation)
• System Administrator access to the Central File Share machine
• Status of Abend-AID Web Browser Interface at your site (if installed, you will need IP address or DNS name plus port of each)
• Status of Abend-AID Fault Analytics at your site (if installed, you will need IP address or DNS name plus port of each)
• Status of iStrobe implementation at your site (if installed, you will need IP address or
DNS name plus port plus web site name of each)
Procedure
1. Read and follow the instructions in Chapter 4, “Compuware Workbench
Installation”.
Note: If planning to implement the optional File-AID Data Privacy plug-in, be sure to include the Data Privacy plug-in during the Compuware Workbench installation, as discussed in the section “Installing Compuware Workbench” in Chapter 4, “Compuware Workbench Installation”
2. When installation of Compuware Workbench is complete, launch Compuware
Workbench using the desktop icon or by selecting Program Files> Compuware >
Compuware Workbench Workbench > eclipse > workbench.exe.
Note: If you chose to install the z/OS Product Plug-ins into your Eclipse or IBM RDz instance, use your standard launch procedure or shortcut.
4. Access the Host and verify basic functionality a. Click on the plus [+] to the left of Hosts to expand the tree to view your host connections in Host Explorer.
b. Click on the plus [+] to the left of your mainframe host. c. Supply access credentials to the mainframe.
Note: Upon first login to the mainframe port, you may receive warning messages on the Console View related to File-AID product installation and version compatibility. These messages are provided to verify availability of
File-AID products needed to fully support the File-AID/Eclipse (Data
Editor and File-AID Search) plug-in on this host port.
2-6
Compuware Workbench Installation Guide
If File-AID products are not installed and licensed, Host Explorer navigation paths for File-AID for DB2 and/or File-AID for IMS may be suppressed, and the ability to invoke the File-AID Data Editor from a list of MVS datasets or UNIX files may be disabled. Similarly, the File-AID
Dataset Search/Update option of the Search menu may not function.
The File-AID Data Editor may limit some functionality if it detects that the version of File-AID is back level or does not contain the most current
PTFs.
Note: The first time you connect to a host, you may be prompted to Register as a user. Please complete the form and click Register to let Compuware
Customer Support know you are a Compuware Workbench user in the event you need to contact Compuware for assistance.
d. Right-click on z/OS Files and select Add New Filter to list your HCI datasets.
(Example filter expression: hlq.MLHCnnn.*
).
e. Expand your new filter and locate and expand the generated PDS library
( hlq.MLHCnnn.GENERATE.PDS
). f. Right-click the member xxxx$004 (this is the JCL you submitted in Milestone I to verify the CSS TP communication) and select Edit.
g. The JCL appears in an Edit window. This is the source editor for working with
JCL and program source. Click the [x] in the Edit window tab to close the edit session. h. Right-click the member xxxx$004. Select Submit to submit the JCL for execution.
i. The Submit Resource information pop-up displays to confirm submission of the
JOB.
j. When the JOB completes, a Host Explorer Job Completion Notification message window displays in Compuware Workbench.
k. Click the link provided in the Job Completion message to view the JOB output in
Compuware Workbench.
Perform step 5 (below) only if you have implemented the Abend-AID Web Browser
Interface, Fault Analytics, or iStrobe, and wish to interface with any of them from the Compuware menu in Compuware Workbench or Eclipse or IBM RDz, use the following procedure to configure those products.
5. Configure the Abend-AID, Fault Analytics or iStrobe plug-ins
Installation Preparation and Checklist
2-7
a. Follow the instructions in “Step 2. Configure Compuware Mainframe Product
Plug-ins (only for the Abend-AID, Fault Analytics, or iStrobe plug-in users)” on page 5-2.
b. Once configured, use the Compuware menu to select each plug-in (Abend-AID
Fault Analytics or iStrobe).
1. When you mouse over the Abend-AID, Fault Analytics or iStrobe plug-ins, a cascade menu appears showing your configured plug-in description (or <No servers defined> if the plug-in was not configured). Move the pointer to the server name you defined and click on it to launch the product. The interface will either launch in a view or in a new browser window.
2. Repeat as needed to validate each plug-in.
Milestone II: Complete — communication to mainframe is configured and working.
2-8
Compuware Workbench Installation Guide
Milestone III: Installing File-AID Data Privacy
Milestone III is necessary only if you are planning to use the File-AID Data
Privacy plug-in for mainframe data disguise.
Detailed installation steps for Data Privacy are described in Chapter 6, “File-AID Data
Privacy”. Before following this checklist, be sure to have completed all previous
Mainframe Milestones.
Note: Mainframe Data Privacy is only supported on z/OS Release 1.10 or higher.
What you will need to complete this Milestone
• an allowance of 2 hours (estimate) to complete this milestone (depending on the status of the installation of the supporting products). Each product needed for File-
AID Data Privacy support has its own configuration process. Typically, it requires 2 to
8 hours to install a File-AID product.
• the File-AID EP and File-AID Test Data Privacy EP media (or equivalent RFN product distributions, including the File-AID/EX and File-AID Distributed Components download media image)
• Compuware Workbench Server download from FrontLine (Windows or Linux, or via
File-AID/EX and File-AID distributed components download)
• Windows or Linux machine to install the Compuware Workbench Server (CWS) (can be the same machine used to install the master Compuware Workbench client and the copy of the Compuware Workbench media). By default, the Compuware
Workbench Server uses open TCP ports 3081, 4082, 4180, and 5180 for communication. If needed, you can override the default ports, after installation, by
using a provided utility as described in “Changing Compuware Workbench Server
Port Assignments” on page E-1. Ensure there are no conflicts using those port
numbers.
• for the z/OS UNIX installation of the File-AID Rules Engine (FARE), you will need:
– two directories, each with at least 50MB of available disk space
– an expert knowledge of the z/OS UNIX system, with privileges to create a directory and knowledge of editing scripts
– the path name of the location of Java on z/OS UNIX is required
– the FARE installation requires about 2 hours.
• Also required is the location of a local or LAN directory containing the DB2 database driver (db2jcc.jar) and license files in case DB2 will be used as a disguise target, rules repository or translate table repository.
Procedure
The following steps are a summary of the descriptions in Figure 6-1 on page 6-1 and
Chapter 6, “File-AID Data Privacy”. You may find it beneficial, before beginning, to
consult the “Data Privacy Installation Flowcharts” on page 6-12.
1. Install the Compuware Workbench Server as described in “Step 1. Install the
Compuware Workbench Server (CWS)” on page 6-2
2. (Only if planning on disguising distributed RDBMS databases.) Verify File-AID/EX 5.3 or
higher is installed and configured for File-AID Data Privacy as discussed in “Step 2.
Install File-AID/EX” on page 6-4. When you configured Dynamic Privacy you verified
that the Execution Server and File-AID Rules Engine were installed on your target execution platform(s).
3. Install the File-AID Rules Engine in z/OS UNIX as described in “Step 3. Install the
File-AID Rules Engine (FARE) on z/OS UNIX” on page 6-5.
Installation Preparation and Checklist
2-9
4. Install File-AID Data Solutions 4.4 or higher and configure for File-AID Data Privacy
as discussed in “Step 4. Install File-AID/Data Solutions” on page 6-6. Verify File-
AID/Data Solutions configuration.
5. Ensure File-AID/Common Components 2.1 or higher is installed as discussed in “Step
5. Install File-AID/Common Components” on page 6-7.
6. Complete “Step 6. Install Additional File-AID Mainframe Products as Needed” on page 6-7.
7. Be sure to modify the CXSS0000 (STASK) proc to reference the required File-AID
considerations for started task detailed in Appendix B, “Security Considerations”
8. Perform step 13, “Configure the CWS in Compuware Workbench” on page 6-3
(optionally, including the configuration of Database connections). Be sure to redefine all host connections on the Compuware Workbench Server.
9. Complete the configuration of Data Privacy security as described in “Step 7. Data
Privacy Security Configuration” on page 6-8.
10. Verify Data Privacy is communicating. Use the Compuware menu to launch the Data
Privacy perspective and the Data Privacy Explorer view. You should be able to see the
File-AID Rules repository listed in the view.
Note: If the repository, File-AID Rules, has a red x icon or cannot be opened, it may need to be migrated to make it current. Use the Data Privacy menu option
Manage Repositories to select the repository and click Migrate. Some processing will occur to migrate the repository and then you should be able to open it and create a new project.
Milestone III Complete — File-AID Data Privacy plug-in is installed and communicating.
2-10
Compuware Workbench Installation Guide
Milestone IV: Configuring Xpediter/Eclipse
Milestone IV is necessary only if you are planning to use the Xpediter/Eclipse plug-in for Xpediter/TSO and /IMS and Xpediter/CICS debugging.
What you will need to complete this Milestone
• an allowance of 4 hours (estimate) for TSO and 4 hours (estimate) for CICS support.
• ensure the Xpediter/TSO and Xpediter/IMS release level supports the release level of
Xpediter/Eclipse plug-in.
• requires the Xpediter/TSO Multi-Batch Facility to be installed.
• the name of the CSS Compile Information Table library (SLCXTABL). This dataset is created during the customization of CSS as described in "Step 4. Create Compile
Information Table (Required)" in the CSS Customization chapter of the Enterprise
Common Components Installation and Customization Guide.
Procedure
1. Set up the CSPF dataset and configure support for Xpediter/Eclipse to work with
Xpediter/TSO as described in “Support for Debugging Batch, IMS and Stored
2. If you intend to debug CICS programs using Xpediter/Eclipse, configure support for
Xpediter/Eclipse to work with Xpediter/CICS as described in “Support for Debugging
Milestone IV: Complete — Xpediter/Eclipse configured to support debugging sessions.
Installation Preparation and Checklist
2-11
Milestone V: Installing and Configuring Support for File-AID/Eclipse
Milestone V is necessary only if you plan to use the File-AID Data Editor plug-in to support browse and edit of DB2 tables, IMS databases, and z/OS files and/or the
File-AID Search/Update plug-in to support the File-AID Search/Update option of the
Search menu.
This milestone covers the installation, configuration, and verification for the operation of the File-AID Data Editor and File-AID Search/Update plug-in. Verification will test using the File-AID Data Editor plug-in to browse a table in DB2, browse a sequential/VSAM file in the z/OS catalog, search a PDS or browse an IMS database.
What you will need to complete this Milestone
• z/OS systems programmer to install the File-AID products you plan to support at your site.
Procedure
1. If you have File-AID/MVS, File-AID for DB2, or File-AID for IMS and plan on using the File-AID Data Editor and File-AID Search/Update plug-ins (part of the File-
AID/Eclipse plug-in), complete the installation of the File-AID products you require
as described in Chapter 7, “File-AID Product Installations and Configurations”.
2. Ensure that the File-AID library (or libraries) you specify in the STEPLIB concatenation of the CXSS0000 (STASK) procedure is defined as APF-Authorized with
system-wide READ access, as discussed in “Step 8. Copy the Generated STASK and
SSAS PROCS to PROCLIB” on page 3-21. Note the security considerations for started
task detailed in Appendix B, “Security Considerations”
3. Use Help > Help Contents to access user guides for all Compuware and associated third-party plug-ins. The File-AID/Eclipse User Guide contains detailed information on using the File-AID Data Editor and the File-AID Search/Update features.
4. Verify VSAM and Sequential files a. If you installed and configured File-AID/MVS, right-click on the z/OS files navigation path and add a filter to list your TSO datasets ( userid.*
). b. Click OK on the filter and right-click on a sequential dataset, PDS member, or
VSAM file in the dataset list. In the context menu that appears, select File-AID
Data Editor. This will bring up the File-AID Data Editor Request dialog box. c. If you have a COBOL or PL/I record layout for the selected file, provide it, otherwise, uncheck the Use Record Layouts checkbox near the upper left portion of the request. d. Click RUN to initiate a browse session. This verifies the basic connection for File-
AID/MVS.
5. Verify DB2 tables a. In Host Explorer select a Host Connection and expand to see the paths. b. Right-click on the File-AID for DB2 path and select Add Filter. c. In the Specify DB2 Filter dialog box, define a filter for a DB2 Subsystem to which you have access. Specify the SSID (Subsystem ID), Creator and Table name — you may use an asterisk (*) as a wild card (you may be asked to supply Login
Credentials). d. Click the adjacent plus sign (+) to expand the list of filters.
e. Click the plus sign (+) to the left of your new filter. f. Expand the list of creators and expand the list of one creator to see a list of tables and views.
2-12
Compuware Workbench Installation Guide
g. Right-click on a table or view and select File-AID Data Editor from the context menu. Click Run on the Request dialog box. The table should appear in a main view window.
h. Browse through the table — scroll right and down. Right-click to see a list of commands.
i. Use the X near the table name at the top of the view to close the table. This validates that the File-AID Data Editor interface is active.
6. Verify IMS database browse a. If you installed and configured File-AID for IMS, right-click on the File-AID for
IMS navigation path and add a filter to list DBDs in one of the environments to which you have access. b. Right-click on a DBD and select File-AID Data Editor from the context menu that appears. c. This will bring up the File-AID Data Editor Request dialog box. Depending on the completeness of your selected environment, you may need to provide record layouts (or to bypass record layout usage on the Record layouts tab of the request) before proceeding. d. Click the RUN button on the bottom right of the dialog box to initiate a browse session. This verifies the basic connection for File-AID for IMS.
7. Verify File-AID Search a. Using the MVS Datasets filter for listing your TSO datasets (which you set up in item 3 to verify MVS browse), right-click a sequential dataset, PDS, or VSAM file in the dataset list. b. In the context menu that appears, select Search. The Search dialog box displays and is opened to the Host Explorer Dataset Search tab.
c. Select the File-AID Dataset Search/Update tab and enter a search text value that you know appears in the selected dataset (for example, if the dataset is a PDS containing COBOL or PL/I layouts look for PIC or DCL respectively). d. Click Search and view the results in the Search view.
Milestone V: Complete — File-AID/Eclipse support is now available to users.
Installation Preparation and Checklist
2-13
Milestone VI: Activating Hiperstation/Eclipse
Milestone VI is necessary only if you plan to use the Hiperstation/Eclipse pluginn conjunction with Hiperstation) to create audit files.
What you will need to complete this Milestone
• an allowance of less than 1 hour
• name of the Hiperstation 8.0 authorized load library
• name of the Hiperstation 8.0 panel library
• ability to modify the CSS TP parameters
• ability to modify the HCI JCL
Procedure
IMPORTANT: In order to install the Hiperstation/Eclipse plug-in, it must be explicitly
selected during a custom installation of Compuware Workbench or during installation into Eclipse or IBM RDz. Make sure to select the Custom install and select the
Hiperstation/Eclipse plug-in during installation of the Compuware Workbench client.
If you have already completed the installation of Compuware Workbench and did not select the Hiperstation/Eclipse plug-in for installation and now wish to add it, follow
the instructions in “Adding Optional or Additional z/OS Product Plug-ins” on page D-2
1. Make sure the HCI JCL is changed to reference the Hiperstation authorized load
library (SQQFLOAD). See Figure 3-21 on page 3-25.
2. The HPERPLIB statement must be added to the CSS TP configuration (default member name CXTP01 in the TPCONFIG dataset) to identify the Hiperstation panel library
(SQQFPENU) name. Refer to “Code the HPERPLIB Statement (Optional)” on page
3. Restart HCI.
4. Use the Compuware menu to start the Hiperstation/Eclipse perspective.
5. If the perspective launches and is able to display audit files, you have properly installed the Hiperstation/Eclipse support.
Milestone VI: Complete — Hiperstation/Eclipse plug-in is installed and tested.
2-14
Compuware Workbench Installation Guide
Milestone VII: Activating Code Coverage/Eclipse
Milestone VII is necessary only if you plan to use the Code Coverage/Eclipse plug-in (used in conjunction with Xpediter/Code Coverage) to work with
Xpediter/Code Coverage analysis and results..
What you will need to complete this Milestone
• an allowance of less than 1 hour
• name of the Xpediter/Code Coverage 3.1 authorized load library
• ability to modify the SASS PROC
Procedure
If you have already completed the installation of Compuware Workbench and did not select the Code Coverage/Eclipse plug-in for installation, or you upgraded Compuware
Workbench from a previous release that did not include Code Coverage/Eclipse, and now
wish to add it, follow the instructions in “Adding Optional or Additional z/OS Product
1. Make sure the CXSSAS procedure is changed to reference the Xpediter/Code
Coverage load library (SLXVLOAD). See Figure 3-20 on page 3-23.
2. Restart HCI.
3. Use the Compuware menu to start the Code Coverage/Eclipse perspective. Use the
Cheat Sheet provided to help you get started with Code Coverage/Eclipse
4. If the perspective launches and is able to display Coverage Analysis results from an
Xpediter/Code Coverage repository you have properly installed the Code
Coverage/Eclipse support.
Milestone VII: Complete — Code Coverage/Eclipse plug-in is installed and tested.
Installation Preparation and Checklist
2-15
Milestone VIII: Configuring CA-ENDEVOR
Milestone VIII is necessary only if you plan to activate the CA-ENDEVOR interface (the appearance of the Endevor folder in Host Explorer).
What you will need to complete this Milestone
• an allowance of less than 1 hour.
• the name of the CAI Endevor authorized load library.
Procedure
1. To activate the Endevor support, make sure the Enable Endevor setting and the CAI
Authlib are provided in the HCCF (See Figure 3-12 on page 3-16 from “Step 5. Specify
Configuration Values for the Profile”).
Note: To remove the Endevor navigation path for this host. Modify the ENABLE statement in the CSS TP configuration and change the
Y
to an
N
ENABLE Statement (Optional)” on page F-8.
2. Restart HCI.
3. In Host Explorer, select a mainframe LPAR and expand to see the paths.
4. Right-click the Endevor path and select Add Filter.
5. In the New Endevor Filter dialog box, use the Environment menu to view available environments. The appearance of a list of accessible environments validates that the
CA-Endevor interface is active.
Milestone VIII: Complete — Endevor interface is installed and tested.
2-16
Compuware Workbench Installation Guide
Milestone IX. Deploy the z/OS Product Plug-ins to End-users
Milestone IX is recommended for all installations.
1. Refer to Chapter 12, “Deployment” for guidelines on deploying Compuware
Workbench to end-users.
2. Test the installation of the z/OS Product Plug-ins from the deployment site and verify that configurations were imported correctly (example: Verify at least one Host
Explorer host LPAR and port is configured).
Milestone IX: Complete — Compuware Workbench Ready for Deployment
Installation Preparation and Checklist
2-17
Non-Mainframe Checklist
This section contains the abbreviated installation checklist for sites that
– are not planning to use Compuware Workbench with a mainframe connection and
– plan to use the File-AID Data Privacy plug-in for use with distributed RDBMS disguise in conjunction with File-AID/EX.
Note: Sites planning to install Compuware Workbench with the intent of communicating with a mainframe should use the full checklist described in
“Mainframe Checklist” on page 2-1.
Installing File-AID Data Privacy (Non-mainframe)
What you will need to complete this Milestone
• the Compuware Workbench media or FTP download from an order
• the File-AID EP and Test Data Privacy EP media (or RFN distribution of File-AID/EX).
• Compuware Workbench Server download from FrontLine for Windows or Linux (or
RFN distribution of the File-AID EX and File-AID Distributed Components media image).
• Windows or Linux machine to install the Compuware Workbench Server (can be the same machine used to install the master Compuware Workbench client and the copy of the Compuware Workbench media). The Compuware Workbench Server (CWS) will use TCP ports (by default, 3081, 4082, 4180, and 5180) on the machine for communication — make sure there are no conflicts. If needed, you can override the
default ports, after installation, by using a provided utility as described in “Changing
Compuware Workbench Server Port Assignments” on page E-1.
• the location of a local or LAN directory containing DB2 UDB database driver and license files — in case DB2 UDB will be used as a disguise target, rules repository, or translate table repository.
Procedure
1. Follow the steps described in Chapter 4, “Compuware Workbench Installation” to install the Compuware Workbench client.
IMPORTANT: Be sure to select the Data Privacy install set during the installation.
Optionally, use the Custom install set and only select the Data Privacy plug-in.
2. Install the Compuware Workbench Server as described in “Step 1. Install the
Compuware Workbench Server (CWS)” on page 6-2.
3. Verify File-AID/EX 5.3 or higher with all service packs is installed and configured for
File-AID Data Privacy as discussed in “Step 2. Install File-AID/EX”, step 1 on page 6-4.
a. Verify File-AID/EX 5.3 or higher Execution Server is installed on target execution platform(s).
b. Verify File-AID/EX 5.3 or higher File-AID Rules Engine (FARE) is installed on target execution platform(s).
4. See Chapter 5, “Compuware Workbench Configurations” for instructions on
configuring and deploying Compuware Workbench in your site.
a. Perform step 13, “Configure the CWS in Compuware Workbench” on page 6-3
(skip the noted instructions for the configuration of host connections, but be
sure to include the configuration of Database connections).
Note: You will NOT need to perform Configuration “Step 1. HCI Connection
and Configuring Hosts” on page 5-1 nor “Step 2. Configure Compuware
2-18
Compuware Workbench Installation Guide
b. Perform “Step 2. Establish Default Update Site” on page 12-2.
5. Complete the configuration of Data Privacy security as described in “Step 7. Data
Privacy Security Configuration” on page 6-8.
6. Verify Data Privacy is communicating. In Compuware Workbench, use the
Compuware menu to launch the Data Privacy perspective and the Data Privacy
Explorer view. You should be able to see the File-AID Rules repository listed in the view. This verifies your configuration.
7. Each File-AID Data Privacy user must install Compuware Workbench (for defining
Dynamic Privacy Rules projects) and File-AID/EX (to execute disguise projects) as
described in steps 1, 3, and 4 of this checklist). Refer to Chapter 12, “Deployment”
for guidelines on deploying Compuware Workbench to end-users.
3-1
Chapter 3.
Communications to the Mainframe
This chapter contains important information that can help you install the mainframe components needed to support the Compuware’s z/OS Product Plug-ins for Eclipse. Please review this chapter before beginning the actual installation process.
IMPORTANT: For the most up-to-date system requirements and installation instructions, please consult the current Compuware Workbench Release Notes by visiting the Compuware
Go customer support Web site at
http://go.compuware.com
.
Note: If you are installing Compuware Workbench purely for non-mainframe File-AID
Data Privacy, you do not need to read this chapter nor set up host communications.
Installation Considerations
Compuware’s Host Communication Interface (HCI) and Compuware Shared Services
(CSS) are required in order to use the z/OS Product Plug-ins to communicate with a mainframe host. Before performing the steps contained in this chapter, HCI and CSS must be installed (either through RFN or as part of the ECC EP media). See the Release
Notes from Compuware GO/FrontLine for more information about supported versions of
HCI and CSS.
If migrating to Compuware Workbench from an earlier release, be sure to review
Appendix C, “Migrating from Previous Versions”. You may be able to use your existing
HCI configuration.
Before installing a new HCI, as described in this chapter, you must apply all available CSS and HCI maintenance updates for the supported versions.
Important: To communicate with more than one LPAR, repeat the procedures in this chapter to configure HCI for each LPAR.
You need to know the dataset names of the following SMP/E controlled libraries:
• CSS Sample library (SLCXCNTL)
• CSS load library (SLCXLOAD)
• CSS APF-Authorized load library (SLCXAUTH)
• HCI load library (SLHCLOAD)
• HCI APF-Authorized load library (SLHCAUTH)
Note: When using the Compuware Installer to generate the JCL to SMPE install CSS or
HCI, tables are created containing these dataset names. These tables can be used as input to the HCCF described later in this chapter.
Note: When using the ECC EP media to upload and install the HCI, CSS, and LMS software, a dataset is created for you containing these DSNs. The dataset is named
hlq.CYnnnnnn.SMPE.DATA
(where
hlq
is the high level qualifier you provided at the time of the upload), and is used as input to the Host
Communication Configuration Facility (HCCF) described later in this chapter.
3-2
Compuware Workbench Installation Guide
Maintenance Level Verification
In order to make sure that you have the most current maintenance applied to your
Compuware products you can use a special CSS utility, The Compuware Maintenance
Utility, to report on the status of your Compuware products. See Appendix H,
“Compuware Maintenance Utility” for details.
Note: The Compuware Maintenance Utility is only available after applying all current
LMS and CSS PTFs.
Pre-installation Considerations for Mainframe Interface
Connection to z/OS Host
Before you install the Host Communication Interface (HCI) on the z/OS host, you must be able to run TCP/IP traffic from the workstation to the host.
To avoid any unpredictable connection issues, make sure all current IBM maintenance is applied to TCP/IP.
Collect TCP/IP Information
• TCP/IP region name
• TCP/IP host name or IP address
• TCP/IP port number
Overview of HCI
The Host Communication Interface (HCI) provides connectivity between products running on the workstation and the mainframe using TCP/IP as the communications protocol.
Figure 3-1. Workstation/Mainframe Connectivity
Workstation 1
Workstation 2
TCP/IP Address
Space
HCI Address
Space
(CSS TP) Communication Tasks
(CSS STASK)
File-AID/Eclipse
Session
HCI is installed from the ECC EP installation media provided in its own shipping package or from Receive from Network (RFN).
HCI has a comprehensive interactive configuration facility, the Host Communication
Configuration Facility (HCCF), you use to set up the datasets and operating parameters needed to support communications.
Note: HCI itself can be started as a batch job or as a started task.
HCI uses a configuration XML file, generated by the HCCF, to control its operation. HCI also uses the Compuware Shared Services mainframe Transaction Program (CSS TP) configuration parameters (initially generated by the HCCF) to control specific facilities of
Compuware Workbench.
Communications to the Mainframe
3-3
Note: The HCI you configure for Compuware Workbench can also be used to support
Strobe installations. Most of the CSS TP parameters apply only to Compuware
Workbench—Strobe only needs CSS TP parameters LOCAL, STASK, and HCI.
When using HCI, all the STEPLIB datasets must be APF-Authorized, therefore the HCI address space runs as authorized.
Install Enterprise Common Components
Installing Compuware Shared Services (CSS), Host Communications Interface (HCI), and License
Management System (LMS)
The most current releases of CSS, HCI, and LMS in SMP/E installation format is provided in its own shipping package, the ECC EP media (or applicable RFN product distributions).
The most current version of the Enterprise Common Components (ECC) Installation and
Customization Guide is available on Frontline and is also provided with the ECC EP media.
Follow the instructions in the Enterprise Common Components (ECC) Installation and
Customization Guide to complete the SMP/E installation of CSS, HCI, and LMS. After you
Note: The supported releases of HCI and CSS require the latest maintenance PTFs to be applied to support the z/OS Product Plug-ins.
Note: No customization of CSS or HCI is required — just complete the SMP/E steps to create the datasets. CSS customization Step 4 (Create Compile Information Table) is recommended if the z/OS Product Plug-ins will be used to Compile programs with Host Explorer.
If any of Compuware’s mainframe products have been successfully installed at your site, you will already have LMS installed and running. All procedures in this guide presume LMS is installed and that appropriate Compuware Mainframe product
licenses are active. Installation of LMS is only discussed in the Enterprise Common
Components (ECC) Installation and Customization Guide.
Install the Mainframe Interface TP
The Compuware Shared Services mainframe Transaction Program (CSS TP) serves as the primary contact point between the mainframe and Compuware Workbench user. The services provided include job submission, output viewing, dataset retrieval and update, launching of Xpediter-based debugging sessions, initiating sub-tasks to support File-
AID/Eclipse or Data Privacy sessions, and many other services. Throughout this document, the transaction program is referred to as the TP or the CSS TP.
The TP runs as a subtask of Compuware’s Host Communication Interface (HCI). HCI is required to run Compuware Workbench. If you have an existing HCI installation that
is already supporting another Compuware product, you should not attempt to use that HCI to support Compuware Workbench. It is recommended that you create a new copy of HCI and configure it for z/OS Product Plug-ins.
Once you have configured HCI for Compuware Workbench you can use that configuration to service other products.
For Strobe sites that use HCI, use the same port number to configure HCI for Compuware
Workbench. The HCI you configure for Compuware Workbench will then run instead of the HCI you have set up for Strobe and it will be transparent to Strobe users.
3-4
Compuware Workbench Installation Guide
For DevEnterprise sites that use HCI, you may optionally merge the HCI you configure for
Compuware Workbench with the HCI you have configured for DevEnterprise (see
Appendix G, “Running a Single HCI to Support Compuware Workbench and
A diagram showing the relationships of the various configuration parameters is provided
Figure 3-2. Relationship of Configuration Specifications for the HCI and TP
RCP Client
Workstation User
Connect to
Port: 16196
1
2
HCI Configuration (HCCF)
ProfileID=SYSID=HC01, TPNAME...=CXTP01
PORT=16196,
3
One or more CICS regions
CICS region: CICS1
Listener Port: 43066
HCI address space
TP Subtask
CXTPMAIN
(one per user)
Dataset:
COMPWARE.HCI.PARMLIB
//HCIXML DD
Member:
HC01XML
HCI Parmlib Member: HC01XML
<HCICNFG>
<HCICNGCA
HCI Parmlib Member: CXTP01
ATTACHX
CXTPMAIN.PARM=’&SYSCXTP01’
4
8
//HCIPARM DD
Member:
CXTP01
Dataset:
COMPWARE.MLCXNNN.SLCXAUTH
Dataset:
COMPWARE.CX.TPCONFIG
Config Member:
CXTP01
//TPCONFIG DD
6
TP Configuration File
Member CXTP01
Local 16196 mvs1.xyzcorp.com
CICS CICS1 port 43066
CSPF DSN=COMPWARE.CX.CSPF
CXSSAS Proc (SSAS)
SSAS address space:
SLCXLOAD
CSPF Dataset:
COMPWARE.CX.CSPF
5
//STEPLIB DD DSN=COMPWARE.MLHCNNN.SLHCAUTH
// DD DSN=COMPWARE.MLCXNNN.SLCXAUTH
CXSS0000 Proc (STASK)
(dynamically allocated when needed)
7
Profile info + dataset pointers
RCP Client: Relationship of host port number, HCI, TP, control parameters, and associated datasets
Points to SLCXTABL
Points to SLXTLOAD
CXSSnnnn Address Space:
SLHCAUTH
SLCXAUTH
CXVJLOAD
SXVJAUTH
SSTRLOAD
CAI.ENDEVOR.AUTHLIB
Load Module:
CXTPMAIN
1 User connects to a host at the designated port 16196
2 HCI looks up the TP name assigned to port 16196, in this example “CXTP01”.
3 HCI finds the parmlib member associated with the TP name CXTP01, in this example also “CXTP01”.
4 HCI finds the TP load module to be used from member
CXTP01. The TP name is passed as a parameter and must match the name in steps 2 and 3.
5 HCI attaches a new subtask TP using the load module identified in step 4.
6 During TP initialization, the TP scans the TP configuration file member that matches the TP name from step 2, which contains connection information , CICS regions, control parameters and the CSPF dataset name.
7 The TP obtains debugging profile and dataset information from the CSPF data set.
8 The TP subtask is now ready to service user requests.
3-6
Compuware Workbench Installation Guide
Part 1: Install and Configure the Host Communication
Interface (HCI)
Skip this chapter if HCI has already been installed and configured on this LPAR for use with Compuware Workbench.
Additional scenarios to consider when setting up and using the Host Communication
Interface (HCI) for each LPAR are:
• HCI is not installed and a new installation of HCI is required. Recommended.
• HCI has already been installed for an existing Compuware product, but a distinct and separate HCI image is intended to support z/OS Product Plug-ins. Recommended.
• HCI is already present for an existing installation of a Compuware product, and is to be used to also support Compuware Workbench. In this case you will configure the
HCI for Compuware Workbench, as described in this chapter, and after configuration you can either use the new configuration to replace your current HCI (Strobe users) or merge the new configuration with your current configuration (DevEnterprise users).
Note: Advantages of configuring an HCI subsystem exclusively for Compuware
Workbench include:
1. In the case where you need to shutdown and restart the HCI serving Compuware
Workbench users, you will not impact HCI usage for other products. Changes to mainframe products used with Compuware Workbench, such as new releases, PTF application or licensing changes often require that HCI be shutdown and restarted to clear its cache of license and product version status.
2. Compuware Workbench user traffic and demands on Compuware Workbench HCI will not impact the performance of other HCI subsystems.
Install and Identify the HCI and CSS Datasets
HCI and Compuware Shared Services (CSS) are installed when Enterprise Common
Components (ECC) is installed, as described in “Install Enterprise Common
Verify that the HCI COMPWARE.MLHCNNN.SLHCxxxx datasets have been established by the SMP/E installation process and updated with current maintenance.
Also verify that the CSS COMPWARE.MLCXNNN.SLCXxxxx datasets have been established, updated with current maintenance, and customized as needed.
Configure a New HCI Image Using the Host Communication
Configuration Facility (HCCF)
The Host Communication Configuration Facility (HCCF) is provided to help you define the HCI JCL and datasets and to configure the initial parameters for the Compuware
Shared Services mainframe Transaction Program (CSS TP) for one LPAR.
Introduction
In order for Compuware Workbench to communicate with a z/OS LPAR, the communications software Host Communications Interface (HCI), must be installed and configured on that LPAR. HCI is provided via Receive from Network (RFN) as an individual product installations or as part of Compuware's Enterprise Common
Components EP media. The Host Communications Configuration Facility (HCCF) is used
Communications to the Mainframe
3-7
to assist in the installation and configuration of HCI. HCI, LMS, and CSS must be installed on the LPAR.
The ECC media provides an automated Mainframe upload and SMP/E installation facility contained within the Media browser. The automated installation facility for ECC, uploads, restores, and performs an SMP/E installation of the ECC software. During the automated installation process, a dataset,
hlq.CYnnnnnn.SMPE.DATA
is created containing the dataset names and other variables related to your installed ECC software.
Note: If you ordered and installed CSS, HCI, or LMS from RFN, you will not have the hlq.CYnnnnnn.SMPE.DATA dataset. However, you may have a repository PDS containing the table for HCI and CSS and that can be used to supply dataset names to the HCCF.
Preparation
Before starting the HCCF, you will need the following:
1. Location of the Compuware Installer PDS provided with your RFN order email, or installed from FrontLine, or from the ECC EP media.
2. Either the name of the repository library created when using the Compuware
Installer to generate RFN SMP/E JCL for installing CSS and HCI; or the fully qualified name of the SMPE.DATA dataset created during the ECC installation from the ECC EP media. If you do not have either of these files, you will need to supply the dataset names where you installed CSS and HCI.
3. Dataset naming convention used for the installed HCI and CSS datasets.
4. The DNS name or IP address of the host you are configuring.
5. Number of an available open port for TCP/IP communications on the LPAR.
6. Name of the TCP/IP subsystem on the LPAR.
7. A 4-character name you choose for the HCI subsystem (
HC01
for example).
8. Access to update a PROCLIB that is in the system PROCLIB search list.
9. A default userID with authority to issue START and SUBMIT commands and authority to write to the HCI Journals.
10. Do you wish to activate the Endevor interface? If so, you will need the dataset name of the CAI Endevor authorized load library.
11. Are you planning on using Compuware DDIO files, or Code Coverage/Eclipse, in
Compuware Workbench? If so, you will need to follow the steps in this chapter to set up the Shared Services Address Space (SSAS) and create journals for it.
Procedure Summary
The following steps outline the basic procedure for using the Host Communications
Configuration Facility (HCCF):
1. Start the facility by using the TSO EX command on member $$HCCNFG of the
Compuware Installer delivered with each RFN order or distributed on Frontline or with the ECC EP media. ( hlq.CPWR.INS
).
2. For media installs: Specify the name of the SMPE.DATA dataset containing the
variables you used to upload and install HCI and CSS from ECC EP media.
For RFN installs, a default dataset name will appear but will likely not exist. This dataset is used to store your HCI configurations for future use. It is recommended you use a name based on the Install dataset from which HCCF was executed to store your configuration profiles. Be sure to keep a record of this name next time you need to run the HCCF utility (for example: hlq.CPWR.INS.SMPE.DATA
).
3-8
Compuware Workbench Installation Guide
3. This dataset is used to store your HCI configurations for future use.
4. It is recommended you use a name based on the Install dataset from which HCCF was executed to store your configuration profiles. Be sure to keep a record of this name next time you need to run the HCCF utility (for example: hlq.CPWR.INS.SMPE.DATA).
5. You may refer to the ISPF table library you specified while using the Compuware
Installer SMP/E JCL Customization facility. If you do not have tables from the installation of CSS and/or HCI you may choose to bypass the use of the ISPF table repository.
6. Create a new configuration profile by cloning the DFLT profile and providing a new profile ID.
7. Edit the new profile to verify datasets and parameters and to specify the configuration you wish to generate.
8. Generate the datasets, PROCs, and JCL for this profile.
9. Submit the generated JCL to create the HCI Journals and the SSAS Journals.
10. Customize and copy the generated STASK and SSAS procs to PROCLIB.
11. Submit the generated HCI JCL to start the HCI subsystem.
Step 1. Start the Host Communication Configuration Facility
The Host Communications Configuration Facility (HCCF) uses screens to gather your configuration information. It then uses that information to build the JCL, datasets, and
PROCs needed to enable a z/OS LPAR to communicate with Compuware products.
Begin the process of configuring host communications using the ISPF Host
Communications Configuration Facility as follows:
1. For media installs: Invoke the facility by entering the TSO EXECUTE command with the dataset name of the ECC EP Installation library followed by $$HCCNFG. For example:
TSO EX 'hlq.CPWR.CYnnnnnn.INS($$HCCNFG)'
for RFN installations, use the Compuware Installer installation library ( hlq.CPWR.INS
).
For Example:
TSO EX 'hlq.CPWR.INS($$HCCNFG)' where
hlq
is the high-level qualifier you entered when creating the Compuware Installer library for your RFN order.
The SMPE.DATA dataset specification screen (Figure 3-3) displays. Note that each screen
is backed by a tutorial explaining screen operation and entries. Press HELP (PF1) to access the tutorials.
Communications to the Mainframe
3-9
Figure 3-3. SMPE.DATA Dataset Specification screen
Host Communications Configuration Facility
Command ==>
Enter the Dataset Name of the PDS (hlq.SMPE.DATA) created during ECC EP
Mainframe Upload or ECC SMP/E JCL Customization. If the Dataset does not
exist or is not available, enter a DSN to store new variables. The new dataset
will be created for you if it does not exist.
==> CYnnnnnn.SMPE.DATA DATASET NOT FOUND
If the Dataset above is correct, press Enter to validate and/or Continue.
Press PF1 for help, END to exit.
Step 2. Provide the SMPE.DATA DSN
In order to simplify the entry of dataset names, the HCCF supports using the SMPE.DATA dataset created during the ECC EP mainframe files upload.
1. Do one of the following:
• Enter the fully qualified dataset name of the
hlq.CYnnnnnn.SMPE.DATA
dataset created when you uploaded ECC files to the mainframe with the ECC EP media browser.
Press Enter to validate the dataset name. If the name is valid the file status will display
DATASET EXISTS. Press Enter to continue and use this dataset.
Note:
To assist you, the HCCF will construct the dataset name based on the dataset name of the Installation PDS you used to execute the HCCF.
OR
• If you do not have the SMPE.DATA dataset and wish to create a new file to preserve the profiles you define with the HCCF, enter a new fully qualified dataset name of your choice and press Enter. If the name is new, the file status will say DATASET NOT
FOUND. Press Enter again and the dataset will be created for you and saved for any future use of the HCCF. You may need to re-enter the name every time you use the
HCCF, so be sure to note the name you use.
TIP: Use a name based on the Installation library from which you executed the HCCF.
For example: hlq.CPWR.INS.SMPE.DATA
.
CAUTION:
If you press Enter when the dataset status is DATASET NOT FOUND, the HCCF will try to allocate a new dataset for you. Make sure that you use a high-level qualifier for which you have write authority. Similarly, if the dataset status is DATASET
EXISTS, the HCCF will attempt to open the file for use. Make sure that you have authority to update the dataset, that the dataset is a valid SMPE.DATA dataset from the ECC EP upload or was created for you by the HCCF, otherwise the HCCF may fail.
Step 3. Enter the Name of the Compuware Installer Table Library
Once you have supplied the SMPE.DATA dataset, or named your own new HCCF dataset,
you will see the Compuware Installer Customization dialog library screen (Figure 3-4).
3-10
Compuware Workbench Installation Guide
Enter the name of the repository library you specified when using the Compuware
Installer dialog to contain your tables. Set Bypass to YES to skip using the repository as a source of dataset names.
Figure 3-4. Compuware Installer Customization dialog library screen
Host Communications Configuration Facility
Command ==>
Enter the Dataset Name of the PDS created by the Compuware Installer
Customization dialog. If the Dataset does not exist or is not available,
set Bypass to YES.
==> TSOID001.CPWR.INS.INSTLIB FILE EXISTS
Bypass: NO
If the Dataset above is correct, press Enter to validate and/or Continue.
Press PF1 for help, END to exit.
Step 4. Create a New or Edit an Existing Profile
Once you have supplied the Compuware Installer repository library or bypassed it, you
will see the Profile Management screen (Figure 3-5).
Figure 3-5. Profile SysID Management Screen
Host Communications Configuration Facility
Command ==>
Enter a Line command to process any of the following HCI configurations.
Valid commands are:
C Clone, D Delete, E Edit, L Lock, U Unlock, G Generate
Cmd SysID Description
More: +
_ DFLT Default Configuration Values - Clone only
Press PF1 for help, END to exit.
1. The Profile Management screen allows you to create new configuration profiles, edit existing profiles, and generate datasets and JCL for a profile. A default profile,
“DFLT Default configuration values, clone only” is always presented. To create a new profile, use the “C” line command to clone the DFLT profile. (Optionally, if you have created one or more profiles, you may clone any profile listed. You may also L (Lock),
U (Unlock), D (Delete), E (Edit), or G (Generate) any profiles you have created.)
Communications to the Mainframe
3-11
2. When you clone a profile, you will be asked to provide a new 4-character
Configuration ID (SysID). The Configuration ID screen displays (Figure 3-6).
Figure 3-6. Clone a profile — Configuration ID (SysID) screen
Host Communications Configuration Facility
Command ==>
Enter the 4 character Configuration ID (SysID) of the new profile
you are creating.
Configuration ID (SysID):
Press Enter to continue, PF1 for help, or END to return to previous panel.
3. Enter a unique 4-character ID to identify the new profile. This ID will also be used as the subsystem name for the HCI when running on the LPAR. For example, use
HC01 for your first profile.
4. Press Enter. You will be taken to the first Configuration screen where you can name
your new profile and enter variables (Figure 3-7).
Step 5. Specify Configuration Values for the Profile
1. When you C (Clone) or E (Edit) a profile, a series of screens display to capture your configuration values.
The first screen to appear is the Profile Configuration screen #1 (Figure 3-7). Fill-in
the values on each screen and press Enter to move to the next screen, press END (PF3) to move to a previous screen. When you have completed editing and generation of your new profile, you will be returned to the Profile Management screen displayed in
Figure 3-5. If you were creating a new profile, your new profile will appear in the list
of profiles. Each screen is backed by a tutorial explaining each value, press HELP
(PF1) to access the tutorials.
If you used the ECC EP media to upload and SMP/E install CSS and HCI, then some of the HCI and CSS dataset names will be filled in for you from the generated
SMPE.DATA dataset. Optionally, if you installed HCI and CSS through RFN using the
Compuware Installer and supplied the Compuware Installer Table LIBARY (as
described previously in “Step 3. Enter the Name of the Compuware Installer Table
Library”), then some of the HCI and CSS dataset names will be filled in for you.
You will also need to specify the fully qualified names you want to use for new datasets created during the Generate process or in the generated JCL.
3-12
Compuware Workbench Installation Guide
Figure 3-7. Profile Configuration Screen #1
Host Communications Configuration Facility
Command ==>
Please enter the following parameters.
Configuration ID (SysID): HC01
Profile Description: HC01 PROFILE FOR HC01
Generated Members PDS: hlq.MLHC300.GENERATE.PDS
TPCONFIG DSN: hlq.MLHC300.TPCONFIG
HCI Parmlib DSN: hlq.MLHC300.PARMLIB
CSS Authorized Load Library DSN: hlq.MLCX900.SLCXAUTH
CSS Load Library DSN: hlq.MLCX900.SLCXLOAD
HCI Authorized Load Library DSN: hlq.MLHC300.SLHCAUTH
HCI Journal1 DSN: hlq.MLHC300.JOURNAL1
HCI Journal2 DSN: hlq.MLHC300.JOURNAL2
HCI Journal3 DSN: hlq.MLHC300.JOURNAL3
HCI Journal Volser (optional):
Press Enter to continue, PF1 for help, or END to return to previous panel.
2. Fill in or verify the fields on Screen #1 (Figure 3-7) and press Enter to continue to
Specify Values as follows:
Profile Description: Enter a description for this profile.
Generated Members PDS: Enter the DSN of a dataset to store members generated for this profile. This dataset will be validated or automatically created and can be changed at Generate time. This dataset should be unique for this LPAR.
TPCONFIG DSN: Enter the DSN of a dataset to store the TPNAME member generated for this profile. This dataset can be changed at Generate time. The
TPNAME member contains the CSS TP parms.
HCI Parmlib DSN: Enter the DSN of a dataset to store the TPNAME and XML members generated for this profile. This dataset can be changed at Generate time.
CSS Authorized Load Lib: Enter the DSN of the SMP/E Installed Compuware
Shared Services Authorized load library (SLCXAUTH).
CSS Load Lib: Enter the DSN of the SMP/E Installed Compuware Shared Services load library (SLCXLOAD).
HCI Authorized Load lib: Enter the DSN of the SMP/E installed HCI Authorized load library (SLHCAUTH).
HCI Journal DSNs: Enter the DSNs to be used to create three Journal datasets to be used by the Host Communications Interface server.
HCI Journal Volser: Enter the Volser for the Journal datasets to be used by the
Host Communications Interface server. Depending on your site standards, this field may not be required.
Communications to the Mainframe
3-13
Figure 3-8. Profile Configuration Screen #2
Host Communications Configuration Facility
Command ==>
Please enter the following parameters.
Configuration ID (SysID): HC01
Enter Job Card Information:
//$$$$$$$$ JOB ('ACCTNO'),'USER NAME ',
// CLASS=?,MSGCLASS=?,NOTIFY=&SYSUID
//* OPTIONAL JES PARAMETER CARD COULD GO HERE
//*
//*
Press Enter to continue, PF1 for help, or END to return to previous panel.
3. Fill-in or verify the fields on the screen and press Enter to continue to Screen #3
Specify Job Card Information as follows:
Enter up to 5 lines of Job Card information. If the information is available from the stored variable file it has been entered for you.
The jobname $$$$$$$$ need not be altered. Job names will be created at generate time and will match the member names of the jobs generated to the Generated members PDS. You may specify your own job name. If you use a $ as the last character of your jobname, a suffix number will be generated for each job generated.
Be sure to validate CLASS and MSGCLASS.
Figure 3-9. Profile Configuration Screen #3
Host Communications Configuration Facility
Command ==>
Please enter the following parameters.
Configuration ID (SysID): HC01
Default UserID:
TPNAME: CXTP01
TCPNAME: TCPIP01
zIIP Enable Option (Y/N): Y
CSS TP Started Task PROC Name: CXSS0000
SSAS Started Task PROC Name: CXSSAS
SSAS System Name: SSAS
SSAS Journal1 DSN: hlq.MLHC300.SSAS.JOURNAL1
SSAS Journal2 DSN: hlq.MLHC300.SSAS.JOURNAL2
SSAS Journal Volser (optional):
Press Enter to continue, PF1 for help, or END to return to previous panel.
4. Fill in or verify the fields on the screen and press Enter to continue to Screen 4
Specify Values as follows:
3-14
Compuware Workbench Installation Guide
Default UserID: The default userid (a value is required). This can be any userid defined to the security system that has sufficient authority to update HCI journals and submit jobs.
TPNAME: The name to use for the CSS TP. Default is CXTP01. This name is used for the member name of the CSS TP parameters kept in the TPCONFIG and HCI parmlib datasets.
TCPNAME: The name of the TCP/IP subsystem running on this LPAR.
zIIP Enable Option: Enable zIIP Processor usage (Y/N).
CSS TP Started Task (STASK) PROC Name: The name of the PROC used to start user subtasks. Only needed for Compuware Workbench sites that are using any of the following: Endevor interface, File-AID/Eclipse, and/or Data Privacy plug-ins.
Also needed for Strobe sites using this HCI to support Strobe. Default is
CXSS0000.
CA-Endevor, File-AID Data Privacy and File-AID/Eclipse cannot execute in the
HCI environment because of security conflicts with HCI. Therefore, all CA-
Endevor or File-AID/Eclipse requests issued by Host Explorer are sent to a startedtask TP by the HCI. The started-task TP will execute the procedure you provide for this purpose. If you are not planning on supporting Strobe or using the
File-AID plug-ins, do not have CA-Endevor installed, or do not wish to make
CA-Endevor available for use by Host Explorer, then you do not need to set
up the STASK. Setting up the STASK procedure (“Step 8. Copy the Generated
STASK and SSAS PROCS to PROCLIB” on page 3-21) and enabling CA-Endevor is
required to prepare for CA-Endevor and/or File-AID or Strobe support.
The name of the procedure should be any 4-characters of your choice or that your installation requires. The last 4-characters should be 0000. The supplied sample procedure has the name CXSS0000. When the HCI starts a TP using this procedure, the last 4-characters will be automatically replaced by the TP number.
Thus, each TP that starts will have a unique jobname, for example: CXSS0001,
CXSS0002, etc.
SSAS Started Task PROC Name: The name of the PROC used to start the
Compuware Shared Services Address space (SSAS). Only needed for Compuware
DDIO support and for Code Coverage/Eclipse. Default is CXSSAS. See Chapter 9,
“Implement the Shared Services Address Space (SSAS)”.
SSAS System Name: The name to use for the SSAS address space. Default: SSAS
SSAS Journal DSNs: Enter the DSNs to be used to create two Journal datasets for the Shared Services Address Space (SSAS).
SSAS Journal Volser: Enter the Volser for the Journal datasets to be used by the
Shared Services Address Space. Depending on your site standards, this field may not be required.
Communications to the Mainframe
3-15
Figure 3-10. Profile Configuration Screen #4
Host Communications Configuration Facility
Command ==>
Please enter the following parameters.
Configuration ID (SysID): HC01
JES Version (2/3): 2
JES3 Command Prefix (JES3 only):
Port Number: 16196
LPAR Name: CW01
System Name: TSO/MVS
Temporary DSN HLQ:
Enter VIPA parms? Y/N: N
IP Address Nbr or Name (220 max): 10.10.0.200
Press Enter to continue, PF1 for help, or END to return to previous panel.
5. Fill in or verify the fields on the screen and press Enter to continue to screen #5
Specify Values as follows:
JES Version: Enter the version of JES being used: 2=JES2, 3=JES3
JES3 Command Prefix: Enter a prefix to use for JES3 commands.
Port Number: (a value is required) Enter a TCPIP Port number not used by any other process. The port is used to listen for Compuware Workbench connections
(For example: 16196).
LPAR Name: Enter the name of the LPAR where the System will run. The default is the name of the LPAR where you are now running the HCCF.
System Name: Enter a descriptive name of the z/OS system to identify this connection to the Compuware Workbench user. Up to 20 characters.
Temporary DSN HLQ: If standards require it, enter up to eight characters of a
High Level Qualifier (HLQ) for allocating Temporary files.
Enter VIPA parms: For Virtual IP Addressing, set switch to 'Y' to enter DVIPA or
DVIPN parameters. Set switch to 'N' to omit Virtual IP Address processing.
IP Address: Enter or verify the IP Address number or DNS Name for the mainframe. A max of 220 characters is allowed for the DNS Name. The default is the current IP address of the LPAR you are running the HCCF. If you use an IP
address it must be an IPV4 format.
3-16
Compuware Workbench Installation Guide
Figure 3-11. Profile Configuration - VIPA Parms
Host Communications Configuration Facility
Command ==>
The VIPA Option on the previous screen was set to 'Y'. Please verify/enter
only one of the following mutually exclusive options. If you set the VIPA
Option to 'Y' in error, please clear both fields and press Enter.
DVIPA (Virtual IP Address):
DVIPN (Virtual IP DNS Name):
Press Enter to continue, PF1 for help, or END to return to previous panel.
This screen only appears if you answered Y to the Enter VIPA parms question on Profile
Configuration Screen #4. Fill-in or verify the fields on the VIPA Parms screen and press
Enter to proceed to Screen #5 (Figure 3-12):
Note: If you do not supply any values on this screen, the Enter VIPA Parms Y/N prompt
on Screen #4 (Figure 3-10) is changed back to N.
You may enter DVIPA or DVIPN, but not both.
DVIPA: Dynamic Virtual IP Address: The format of this field consists of four 3digit numbers separated by periods. Leading zeros are not required.
DVIPN: Dynamic Virtual IP DNS Name: Enter a Virtual DNS Name to use for the
DVIPN Option. A max of 220 characters is allowed for the virtual DNS Name.
Figure 3-12. Profile Configuration Screen #5
Host Communications Configuration Facility
Command ==>
Please enter the following parameters.
Configuration ID (SysID): DDDD
Audit to Job Log (Y/N): N
SYSOUT View Access: DEFAULT (BY-USERID or DEFAULT)
Enable SYSCMD parms? Y/N N
Enable SYSLOG parms? Y/N N
Job Notification (Y/N) Y
Job Notify Purge Time: 2 (values are 0-9 days; 0 = no purge.)
Job Notify Scope: ALL (ALL or LOCAL)
Inactivity Time-out minutes: 0
Enable Endevor (Y/N): N
CAI Authorized Load Library DSN:
Press Enter to continue, PF1 for help, or END to return to previous panel.
6. Fill-in or verify the fields on the screen and press Enter to display the Generate
Communications to the Mainframe
3-17
Note: All of the fields on this screen are specific to the HCI for z/OS Product Plug-ins, if you are using the HCCF to configure HCI for Strobe use only, you can accept all the defaults and just press Enter. None of these fields are required to be set initially, you can accept the defaults and press Enter and later edit the TP
Configuration member to change any of these settings.
Specify Values as follows:
Audit to Job Log: This setting controls whether security messages will be written to the HCI job log when a user attempts access to dataset resources that are
denied. For more information see “Code the AUDIT Statement (Optional)” on page F-11.
SYSOUT View Access: This setting can limit access to SYSOUT data by userid.
When BY-USERID is specified, the user can view only their own output (the user must be the owner). If DEFAULT is specified, then access to SYSOUT data by all users is controlled by the JESSPOOL resource class and your security software
settings. For more information see “Code the SYSOUT Statement (Optional)” on page F-12.
Enter SYSCMD Parms: (future use)
Enter SYSLOG Parms: N (No, Default) disables SYSLOG support. Y (Yes) enables
SYSLOG support and causes an additional screen to appear to capture security rule processing (Figure 3-14)
Job Notification: Enable Job completion notification (Y/N). For more
information see “Code the NOTIFY Statement (Optional)” on page F-21.
Job Notify Scope: Enter
All
to be notified of Job Completion from all LPARs where submitted job runs; LOCAL for only the HCI LPAR. For more information
see “Code the NOTIFYONLY Statement (Optional)” on page F-22.
Inactive Timeout Minutes: User Timeout interval in minutes. Valid range is 0 —
32767 minutes. If 0 is specified, time out is disabled. For more information see
“Code the INACTIVITY Statement (Optional)” on page F-13.
Enable Endevor: Enable Endevor processing for Compuware Workbench users
(Y/N). For more information see “Code the ENABLE Statement (Optional)” on page F-8.
CAI Authorized Loadlib: Enter the DSN of the Computer Associates Authorized
Load library (CAIAUTH). Endevor users only.
3-18
Compuware Workbench Installation Guide
Figure 3-13. Profile Configuration - SYSLOG Parms
Host Communications Configuration Facility
Command ==>
The SYSLOG Option on the previous screen was set to 'Y'. Please verify/enter the
following options. If you set the SYSLOG Option to 'Y' in error, please clear all fields and press Enter.
Rule Choice: SYSTEM
Enter only if Rule Choice is IOF:
IOF Security Class:
IOF Resource Profile:
Press PF1 for help, END to exit.
This screen only appears if you answered Y to the Enter SYSLOG parms question on
Profile Configuration Screen #5. Fill in or verify the fields on the SYSLOG Parms screen and press Enter to proceed to the next screen:
Rule Choice: SYSTEM (default) or SDSF or IOF. Select a type of rule to use to validate user security access to view the system Log.
IOF Security Class: (IOF rules only) Specify the IOF Class
IOF Resource Profile: (IOF rules only) Specify the IOF resource profile name.
For more information refer to “Code the SYSLOG Statement (Optional)” on page
Figure 3-14. Generate Prompt
Host Communications Configuration Facility
Command ==>
Profile editing is complete.
Would you like to generate this profile? Y/N: N
7. Answer
Y
to proceed to Generate processing or
N
to return to the Profile Management
Step 6. Generate the Datasets, PROCs, and JCL for this Profile
After you have completed specifying configuration values for your profile you are ready to generate datasets and JCL. During generation processing, Six (6) members are created/replaced in the Generated Members PDS. Where xxxx
is the SysID: xxxx$001
— JCL to create HCI journals xxxx$002
— JCL to create SSAS journals xxxx$003
— JCL to run HCI
Communications to the Mainframe
3-19
xxxx$004
— JCL to run CSSTPIVP verification xxxxCXSS
— JCL for the STASK proc xxxxSSAS
— JCL for the SSAS proc
In addition, the TPCONFIG and the HCI Parmlib DSNs you specified on Configuration
Screen #1 (Figure 3-7) are created and populated with members based on the values you
specified.
TPCONFIG — TPNAME member containing all CSS TP parameters.
HCI Parmlib — a TPNAME member containing an EXEC statement, and a xxxxXML member containing all HCI definition parameters.
1. If you answered
Yes
to the Profile Generate Prompt screen (Figure 3-14), skip to the
next step (2). Otherwise, on the Profile Management screen (Figure 3-15), Enter the G
(Generate) line command for the profile you wish to Generate.
Figure 3-15. Profile Management — HC01 Profile created - G to Generate JCL.
Host Communications Configuration Facility
Command ==>
Enter a Line command to process any of the following HCI configurations.
Valid commands are:
C Clone, D Delete, E Edit, L Lock, U Unlock, G Generate
Cmd SysID Description
More: +
_ DFLT Default Configuration Values - Clone only
g HC01 PROFILE HC01
Press PF1 for help, END to exit.
2. The Generate PDS confirmation screen displays (Figure 3-16). The dataset name you
specified in Generated Members PDS parameter on configuration screen #1 (Figure 3-
7) appears. You may change the name if you wish. When you press Enter the dataset is
created if the status is DATASET NOT FOUND.
CAUTION:
If you press Enter when the dataset status is DATASET NOT FOUND, the HCCF will try to allocate a new dataset for you. Make sure that you use a high-level qualifier for which you have write authority. Similarly, if the dataset status is DATASET
EXISTS, the HCCF will attempt to open the file for use. Make sure that you have update authority and that the dataset is a valid GENERATE.PDS dataset from a prior execution of the Generate facility, otherwise the HCCF may fail.
3-20
Compuware Workbench Installation Guide
Figure 3-16. Confirming Generate PDS
Host Communications Configuration Facility
Command ==>
Configuration: HC01 ==> PROFILE HC01
Enter the Dataset Name of a PDS to contain the stored members to be generated
for this profile. If the dataset currently exists, any existing customization
members for this profile name will be overwritten.
If the dataset specified does not exist, it will be created for you when you
press ENTER.
HCI.GENERATE.PDS DATASET NOT FOUND
If the Dataset above is correct, press Enter to continue.
Press PF1 for help, END to exit.
3. The HCI Parmlib and CSS TP Configuration datasets confirmation screen displays
(Figure 3-17). The dataset names you specified in HCI Parmlib and TPCONFIG
parameters on Configuration screen #1 (Figure 3-7) appear. You may change a name
if you wish. When you press Enter the datasets are created if the status is DATASET
NOT FOUND. You must use a different DSN for each of the datasets since a PDS member (tpname) is created in both datasets.
CAUTION:
If you press Enter when the dataset status is DATASET NOT FOUND, the HCCF will try to allocate a new dataset for you. Make sure that you use a high-level qualifier for which you have write authority. Similarly, if the dataset status is DATASET
EXISTS, the HCCF will attempt to open the file for use. Make sure that the datasets are valid from a prior execution of the Generate facility, otherwise the HCCF may fail. Also be aware that for an existing HCI Parmlib dataset, the TPNAME and xxxxXML members will be overwritten, and for an existing CSS TP Configuration dataset, the TPNAME member will be overwritten.
Figure 3-17. Confirming HCI Parmlib and CSS TP Configuration DSNs
Host Communications Configuration Facility
Command ==>
Configuration: HC01 ==> PROFILE HC01
The HCI Parmlib and the CSS TP Configuration File are used to store several
output members for this profile. The TPNAME you specified for this profile
is used as a member name in both datasets. Therefore the HCI Parmlib
and the CSS TP Configuration datasets must have unique names (cannot
be the same PDS). If these datasets do not exist they will be created.
HCI Parmlib
HCI.PARMLIB DATASET NOT FOUND
CSS TP Configuration File
TPCONFIG DATASET NOT FOUND
If the Datasets above are correct, press Enter to generate configuration
members.
Communications to the Mainframe
3-21
4. After you complete the HCI Parmlib and CSS TP Configuration dataset screen and press Enter, the datasets are created and the Generate status screen displays
(Figure 3-18). Messages confirm the generate process. Press END (PF3) to exit the
status display and return to the Profile Management screen.
Figure 3-18. Generate Processing Status Display
Compuware Enterprise Common Components Release 3.3
Installation Customization Facility
---------------------------------------------------------------
Member: CXTP01 Job Name: N/A - Customized
Member: CXTP01 Job Name: N/A - Customized
Member: HC01$001 Job Name: HC01$001 - Customized
Member: HC01$002 Job Name: HC01$002 - Customized
Member: HC01$003 Job Name: HC01$003 - Customized
Member: HC01$004 Job Name: HC01$004 - Customized
Member: HC01XML Job Name: N/A - Customized
Member: HC01SSAS Job Name: N/A - Customized
Member: HC01CXSS Job Name: N/A - Customized
*** JCL customization process ended at 17:35:46 ***
Press PF1 for help, END to exit.
Step 7. Submit the JCL to create the HCI Journals and SSAS Journals
After you have completed the generate process for your profile you are ready to create the
HCI and SSAS journals by submitting the generated JCL. During generation processing,
2 journal create JCL members are created/replaced in the Generated Members PDS. Where xxxx
is the Profile ID: xxxx$001
— JCL to create HCI journals xxxx$002
— JCL to create SSAS journals
You must Submit the xxxx$001
JCL to create the HCI journals before starting the HCI.
Review the JCL before submitting to make sure it conforms to your site standards.
The xxxx$002
JCL creates the SSAS Journals and is only required if you are going to deploy the optional SSAS address space to enable Compuware DDIO file support or Code
Coverage/Eclipse. For more information about the SSAS (see Chapter 9, “Implement the
Shared Services Address Space (SSAS)”).
Step 8. Copy the Generated STASK and SSAS PROCS to PROCLIB
Prior to starting the HCI, copy two PROCs from the Generated Members PDS to your system PROCLIB. During the copy, rename the members to match the PROC names.
During generation processing, 2 members containing PROCs are created/replaced in the
Generated Members PDS. Where xxxx is the Profile ID: xxxxCXSS
— JCL for the STASK proc: Copy this member to PROCLIB and rename this member to match the name on the PROC statement and specified in parameter
CSS
TP Started task PROC name
shown in “Profile Configuration Screen #3” Figure 3-9
(Default name is CXSS0000).
3-22
Compuware Workbench Installation Guide
Figure 3-19. CXSS0000 sample CSS TP start-up STASK procedure (member xxxxCXSS)
//CXSS0000 PROC PROG=IEFBR14
//*
//* THIS JOBSTREAM IS USED TO EXECUTE THE CSS TP AS A STARTED TASK
//*
//* ALL STEPLIB LIBRARIES MUST BE APF-AUTHORIZED
//* 1. IF YOU WISH TO SUPPORT THE FILE-AID DATA EDITOR,
//* UNCOMMENT AND VERIFY THE FILE-AID CUST LIB (CXVJLOAD)
//* AND FILE-AID DIST LIB (SXVJAUTH)
//* 2. IF YOU WISH TO SUPPORT STROBE,
//* UNCOMMENT AND VERIFY THE STROBE AUTHLIB
//* (SSTRLOAD) DSN AND THE DB2 SDSNLOAD DSN
//* 3. COPY THIS ENTIRE PROCEDURE TO A SYSTEM PROCLIB.
//*
//IEFPROC EXEC PGM=&PROG,
// REGION=0M,
// PARM=('&TPNAME')
//STEPLIB DD DISP=SHR,DSN=HLQ.MLHC300.SLHCAUTH
// DD DISP=SHR,DSN=HLQ.MLCX900.SLCXAUTH
//* DD DISP=SHR,DSN=COMPWARE.MXVJNNN.CXVJLOAD <== FA CUST LIB
//* DD DISP=SHR,DSN=COMPWARE.MXVJNNN.SXVJAUTH <== FA DIST LIB
//* DD DISP=SHR,DSN=COMPWARE.STRNNN.SSTRAUTH <== STROBE
//* DD DISP=SHR,DSN=DSNxxx.SDSNAUTH <== STROBE SQLAF DB2
//TPCONFIG DD DISP=SHR,DSN=HLQ.MLHC300.TPCONFIG
Caution: All datasets in the STASK proc STEPLIB must be APF Authorized and must have universal read access.
Important: If you are planning to use the File-AID Data Editor or Data Privacy, be sure to verify and uncomment the DD for the File-AID libraries in the
STEPLIB concatenation. See Chapter 7, “File-AID Product Installations and
Important: If using this HCI configuration to support Strobe Web Services or
SQLAF, the STEPLIB datasets to be activated for Strobe are:
STRnnn.SSTRAUTH
(can be in the LINKLIST)
DSNxxx.SDSNLOAD
(if not in LINKLIST).
Add
//*SBSQLTRC DD DUMMY UNCOMMENT IF REQUESTED
/
/*SBSQLSNP DD DUMMY UNCOMMENT IF REQUESTED
Depending on your installed releases of File-AID products, you may optionally code each of the File-AID libraries in the STEPLIB concatenation of the STASK procedure. When specifying individual libraries for each File-AID product,
• File-AID/Common Components (SXVJAUTH and CXVJAUTH) is required for all File-
AID product releases prior to 10.1. For File-AID 10.1or higher there are no separate product libraries, there are only two required datasets CXVJLOAD and SXVJAUTH.
• File-AID for DB2 6.3 (SXFDAUTH) is only needed to support DB2 table browse/edit in the File-AID Data Editor.
• File-AID/MVS 9.4 (SXFAAUTH and CXFALOAD) is only needed to support z/OS files browse/edit in the File-AID Data Editor and File-AID Dataset Search in the Search menu..
• File-AID for IMS 7.7 (SXIXAUTH and CXIXLLIB) is only needed to support IMS database browse/edit in the File-AID Data Editor.
Option 1 - Use the File-AID 10.1 or higher customization (CXVJLOAD) and distribution
authorized load library SXVJAUTH (as shown in Figure 3-19).
Communications to the Mainframe
3-23
Note: Versions of File-AID prior to version 10.1 cannot be mixed with the libraries of
Option 2 - Specifying individual libraries for each supported product when File-AID for
DB2 6.3 is being used for DB2 browse/edit support:
//STEPLIB DD DISP=SHR,DSN=HLQ.MLHC300.SLHCAUTH
// DD DISP=SHR,DSN=HLQ.MLCX900.SLCXAUTH
// DD DISP=SHR,DSN=COMPWARE.MXVJ210.SXVJAUTH <== FA/COM 2.1
// DD DISP=SHR,DSN=COMPWARE.MXVJ210.CXVJAUTH <== FA/COM 2.1
// DD DISP=SHR,DSN=COMPWARE.MXIX770.SXIXAUTH <== FA/IMS 7.7.0
// DD DISP=SHR,DSN=COMPWARE.MXIX770.CXIXLLIB <== FA/IMS 7.7.0
// DD DISP=SHR,DSN=COMPWARE.MXFD630.SXFDAUTH <== FA/DB2 6.3.0
// DD DISP=SHR,DSN=COMPWARE.MXFA9XX.SXFAAUTH <== FA/MVS 9.X.X
// DD DISP=SHR,DSN=COMPWARE.MXFA9XX.CXFALOAD <== FA/MVS 9.X.X xxxxSSAS
— JCL for the SSAS proc: If you are planning to use the SSAS, copy this member to PROCLIB and rename this member to match the name on the PROC statement and
specified in Figure 3-9. (Default name is CXSSAS). For more information about the SSAS
see Chapter 9, “Implement the Shared Services Address Space (SSAS)”.
Figure 3-20. SSAS Start-up Procedure (member xxxxSSAS)
//CXSSAS PROC
//*
//* THIS JCL IS THE SSAS START-UP PROCEDURE.
//*
//* THIS PROCEDURE IS STARTED AUTOMATICALLY BY HCI AS NEEDED; THIS
//* PROCEDURE SHOULD NOT BE STARTED MANUALLY.
//*
//*
//* 1. VERIFY THE DATASET NAME OF THE CSS LOADLIB (SLCXLOAD).
//*
//* 2. IF YOU HAVE XPEDITER/CODE COVERAGE INSTALLED, UNCOMMENT
//* AND VERIFY THE DATASET NAME OF THE CODE COVERAGE
//* LOADLIB (SLXVLOAD).
//*
//* 3. COPY THIS ENTIRE PROCEDURE TO A SYSTEM PROCLIB.
//*
//*
//IEFPROC EXEC PGM=CXASINIT,
// PARM=('&TPNAME'), ** DO NOT CHANGE THIS PARM VALUE **
// REGION=0M
//STEPLIB DD DISP=SHR,
// DSN=COMPWARE.MLCXNNN.SLCXLOAD <== VERIFY CX
//* DD DISP=SHR,
//* DSN=COMPWARE.MLXVNNN.SLXVLOAD <== VERIFY XV
Step 9. Submit the HCI JCL to Start the HCI Subsystem
After you have created the journals and copied the generated PROCs to PROCLIB, you are ready to start the HCI. During generation processing, JCL to start the HCI was created/replaced in the Generated Members PDS. Where xxxx
is the Profile ID: xxxx$003
—JCL to run HCI
The job has two steps (see Figure 3-21 on page 3-25):
1. INITLOG — execution of utility IDCAMS, which initializes the Journal datasets.
3-24
Compuware Workbench Installation Guide
2. HCI — execution of HCIMMAIN, the Host Communications Interface (HCI) main program.
In the HCI STEP, the supplied STEPLIB contains commented out placeholder DDs for the
Xpediter/TSO authorized library (SLXTAUTH), the Hiperstation authorized library
(SQQFLOAD), and also the Strobe authorized load library (SSTRAUTH). You will have further directions on activating the Xpediter/TSO, and Hiperstation DDs later in the
Compuware Workbench installation, if applicable. If using this HCI configuration to support Strobe, uncomment and verify the DD for the Strobe authorized load library
(SSTRAUTH).
Review the JCL. Make sure the JOB Class and Time parameters allow for a continuously running job. Submit the JCL to start the HCI.
IMPORTANT: It is recommended that once the HCI is implemented, it should be set up to run as a started task and included in the IPL startup sequence.
Communications to the Mainframe
3-25
Figure 3-21. xxxx$003 HCI Startup JCL Example
//* THIS JOBSTREAM IS USED TO START THE HCI.
//*
//* 1. ALL LOAD LIBRARIES IN STEP HCI-STEPLIB CONCATENATION MUST
//* BE APF AUTHORIZED.
//*
//* 2. IF THIS HCI IS TO BE USED TO SUPPORT XPEDITER/ECLIPSE,
//* UNCOMMENT AND VERIFY THE XPEDITER/TSO AUTHLIB (SLXTAUTH) DSN
//*
//* 3. IF THIS HCI IS TO BE USED TO SUPPORT HIPERSTATION/ECLIPSE,
//* UNCOMMENT AND VERIFY THE HIPERSTATION AUTHLIB (SQQFLOAD) DSN
//*
//* 4. IF THIS HCI IS TO BE USED TO SUPPORT STROBE,
//* UNCOMMENT AND VERIFY THE STROBE AUTHLIB (SSTRAUTH) DSN
//*
//*
//* *******************************************************
//* * INITLOG STEP - INITIALIZE HCI JOURNALS *
//* *******************************************************
//*
//INITLOG EXEC PGM=IDCAMS,REGION=2M
//JOURNAL1 DD DISP=SHR,
// DSN=HLQ.MLHC300.JOURNAL1
//JOURNAL2 DD DISP=SHR,
// DSN=HLQ.MLHC300.JOURNAL2
//JOURNAL3 DD DISP=SHR,
// DSN=HLQ.MLHC300.JOURNAL3
//DUMMY DD DSN=NULLFILE,DCB=(RECFM=VB,LRECL=255,BLKSIZE=3100)
//SYSPRINT DD SYSOUT=*
//SYSIN DD *
REPRO INFILE(DUMMY) OUTFILE(JOURNAL1) REUSE
REPRO INFILE(DUMMY) OUTFILE(JOURNAL2) REUSE
REPRO INFILE(DUMMY) OUTFILE(JOURNAL3) REUSE
//*
//*
//* *******************************************************
//* * HCI - START UP THE HCI SERVER *
//* *******************************************************
//*
//HCI EXEC PGM=HCIMMAIN,REGION=64M,DYNAMNBR=125
//STEPLIB DD DISP=SHR,
// DSN=HLQ.MLHC300.SLHCAUTH
// DD DISP=SHR,
// DSN=HLQ.MLCX900.SLCXAUTH
//* DD DISP=SHR,DSN=COMPWARE.MLXTNNN.SLXTAUTH <== VERIFY
//* DD DISP=SHR,DSN=COMPWARE.QQFNNN.SQQFLOAD <== VERIFY
//* DD DISP=SHR,DSN=COMPWARE.STRNNN.SSTRAUTH <== VERIFY
//*
//HCIPARM DD DISP=SHR,
// DSN=HLQ.MLHC300.PARMLIB
//TPCONFIG DD DISP=SHR,
// DSN=HLQ.MLHC300.TPCONFIG
//HCIXML DD DISP=SHR,
// DSN=HLQ.MLHC300.PARMLIB(HC01XML)
//HCIJCL DD SYSOUT=(A,INTRDR)
//SYSPRINT DD SYSOUT=*
//HCIERR DD SYSOUT=*
//ABNLIGNR DD DUMMY
//IDIOFF DD DUMMY
//
Controlling the HCI:
Once the HCI completes initialization, you may enter console commands by replying to the outstanding message:
*rr HC9999A xxxx ENTER HCI COMMAND V300
Where rr is the message number and xxxx is the HCI subsystem ID (HC01 for example).
Valid common commands are:
/ rr,SHUTDOWN
(normal shutdown)
/ rr,SHUTDOWN IMMED
(forced shutdown)
3-26
Compuware Workbench Installation Guide
/ rr,SWAP
(swap journals)
Refer to the HCI User Reference for complete details of valid commands.
Note: In rare situations (for example, HCI abends), initialization and startup of HCI may issue another console message indicating a duplicate HCI. In this case, to start the HCI you must reply U continue to restart HCI. (/ rr,U)
Part 2: Using the TP Installation Verification Utility
A simple utility program can be used to verify if the TP and HCI are able to communicate after the install and configuration has been completed. The utility will attempt to establish a connection with the HCI on the designated port and validate that it can send and receive data. The utility will also verify that any valid Compuware mainframe product license is available, which is required for using Host Explorer.
To use the utility, review and submit the JCL generated in member xxxx$004 of the
Figure 3-22. Sample JCL in the Generated Members PDS xxxx$004 member
//*
//* CSS TP COMMUNICATION VERIFICATION UTILITY
//*
//* JOBSTREAM TO VERIFY THAT THE HCI AND CSS TP ARE INSTALLED
//* AND CONFIGURED.
//*
//*
//IVP EXEC PGM=CXTPIVP,REGION=1M,TIME=(,20)
//*
//STEPLIB DD DISP=SHR,DSN=COMPWARE.MLCXNNN.SLCXLOAD <== VERIFY
//SYSPRINT DD SYSOUT=*
//SYSIN DD *
HOSTIP=MVS1.XYZCORP.COM <== VERIFY
PORT=16196 <== VERIFY
/*
Figure 3-23. TP Connection established example
Compuware Shared Services TP Connection Verification Utility
Control statement specification:
HOSTIP=MVS1.XYZCORP.COM
PORT=16196
OPEN connection RC = 00, ERRNO=00000
SEND data RC = 00, ERRNO=00000
RECV data RC = 00, ERRNO=00000
SEND data RC = 00, ERRNO=00000
RECV data RC = 00, ERRNO=00000
Connection to the port was successfully validated.
Valid Compuware mainframe product license verified.
If a connection cannot be established, or there are error conditions present, the output
might resemble the example in Figure 3-24, along with suggested causes and areas that
might require verification.
Communications to the Mainframe
3-27
Figure 3-24. Example of TP Connection not established
Compuware Shared Services TP Connection Verification Utility
Control statement specification:
HOSTIP=MVS1.XYZCORP.COM
PORT=46806
OPEN connection RC = 00, ERRNO=00000
SEND data RC = 00, ERRNO=00000
RECV data RC = 28, ERRNO=00054
The connection was unexpectedly terminated. Possible causes:
* HCI configuration macros HCICNPCB or HCICNTPT are not correctly set.
* The PORT number specified is a secure port via AT-TLS.
* The PORT number specified is an active port, but is in use by another kind of
application.
Different messages could be output depending on the exact return code received during operation.
If a connection to HCI is established, messages will be issued and will be visible in the
HCI job log. The messages might resemble the example in Figure 3-25.
Figure 3-25. Example messages from an established HCI connection
CXTPMAI009I 0001 Init CXTP01 H08824D0
CXTPCFG019I 0001 Configuration file CXTP01 successfully processed
CXTPMAI043I 0001 Ping from 10.10.0.200
CXTPMAI007I 0001 Term RC=00000000 FDBK=0 Reason=00000000
Additionally, messages will be shown in the job log of the CXTPIVP utility execution.
These messages might resemble the example in Figure 3-26.
Figure 3-26. Example job log messages from CXTPIVP utility execution
IEF403I CXTPIVP0 - STARTED - TIME=07.14.59
+CXCM001I HOST 10.10.0.200 ACTIVE
+CXCM002I ATTEMPTING CONNECTION WITH IP 10.10.0.200:16196
+CXCM003I CONNECTION SUCCESSFUL
+CXCM005I CONNECTION CLOSED
IEF404I CXTPIVP0 - ENDED - TIME=07.14.59
3-28
Compuware Workbench Installation Guide
4-1
Chapter 4.
Compuware Workbench Installation
This chapter contains important information that can help you install the Compuware
Workbench client or, alternatively, Compuware’s z/OS Product Plug-ins into an existing
Eclipse IDE or IBM RDz environments. Please review the installation procedures in this chapter before beginning any installation process. The installation process assumes this is to be the initial installation of the Compuware Workbench client and z/OS Product
Plug-ins. However, if you are migrating to the Compuware Workbench from a prior
release, see Appendix C, “Migrating from Previous Versions”.
Installing the Compuware Workbench Client and z/OS
Product Plug-ins
Compuware Workbench Client
The Compuware Workbench client is based on the Eclipse Foundation workbench for
Java developers. The Compuware Workbench, unlike Eclipse, is specifically designed to effectively interface with Compuware’s Programmer Productivity and Test Data Privacy
Solutions using various z/OS Product Plug-ins. Some of the plug-ins are available individually and can be installed into an Eclipse IDE or IBM RDz environment, as
described in “Installing Compuware’s z/OS Product Plug-ins into Eclipse or IBM RDz” on page 4-3.
Installation Overview
This chapter includes information on installation considerations. Topics presented in this chapter include:
• “Install the Compuware Workbench Client”. Using the Media Browser to install the
client on Windows.
• “Installing Compuware’s z/OS Product Plug-ins into Eclipse or IBM RDz”.
This manual describes the installation of the Compuware Workbench for a single user.
Typically, an administrator installs a copy of the Compuware Workbench in order to perform its initial configuration and establish preferences, which in turn can be used by others that wish to use the Compuware Workbench client or associated plug-ins. The administrator then stages the installation (through media or repository) and preferences to a central location, so individual users can access them and install them to their workstation. The readme.htm
file is provided, containing user instructions on how to
install and import preferences. Please refer to Chapter 5, “Compuware Workbench
Configurations” for more details.
Install the Compuware Workbench Client
IMPORTANT: For Windows Vista, Windows 7, Windows 8.1 and Windows Terminal
Server (and Citrix) installations, the userid (recommend
Administrator
) must have write access to the target installation directory (default
C:\Program
Files\Compuware\Workbench
).
Step 1. Run the setup.exe
file located in the root directory of the Compuware
Workbench media. If the media being used for the installation is a CD/DVD and
Autorun is enabled, the Media Browser runs automatically. Otherwise, use
4-2
Compuware Workbench Installation Guide
Windows Explorer to locate the file on the CD/DVD or in the extracted downloaded media and double-click the setup.exe
to launch the Media
Browser.
Step 2. In the Workstation tab, click the Install Compuware Workbench link. The
Install Anywhere wizard for the Compuware Workbench client starts. The
Introduction screen displays.
Step 3. Click Next. The License Agreement screen appears. Read the license agreement, then select the I accept the terms of the License Agreement radio button.
Step 4. Click Next. The Choose Install Set screen appears.
Step 5. Three options are provided:
• Developer Productivity (default selection) — installs all plug-ins except for
Data Privacy and Hiperstation/Eclipse
• Data Privacy — only installs Data Privacy, File-AID/Eclipse and SlickEdit
• Custom — allows you to select specific plug-ins to install. (Use this option to install Hiperstation/Eclipse plus any or all supplied plug-ins)
Make your selection or accept the default and click Next. If you did not choose
Custom, the Choose Install Folder screen appears, go to Step 7. If you chose
Custom, the Choose the components to be Installed screen appears.
Step 6. (Custom selection of components). By default the Custom Set of plug-ins is set to install all plug-ins except for Data Privacy and Hiperstation/Eclipse. You may choose to select or de-select any of the listed components by clicking the checkbox next to each component. When you are satisfied with your selections, click
Next. The Choose Install Folder screen appears.
Step 7. Specify a destination folder for this installation. Accept the default folder by clicking Next, or select Choose... to specify a different destination directory.
Optionally, you can overtype the destination folder with your own folder name and click Next to use that folder for the installation of the Compuware
Workbench. The Shortcuts screen appears.
Note: You may not install a new Workbench 5.0 client to a directory that already contains a version of the Compuware Workbench An uninstall should
be done first, please see Appendix C, “Migrating from Previous Versions”
Step 8. Use the Shortcuts screen to optionally create a Desktop shortcut and program menu entry for the Compuware Workbench. It is highly recommended to check these to create an easy way to start the Compuware Workbench. Click Next.
The Pre-Installation Summary screen appears
Step 9. Confirm the specified destination folder, install set and product plug-ins. If everything is correct, click Install to begin installation of the Compuware
Workbench on the workstation.
Note: The installation may take several minutes due to several factors including the capability of hardware running the installation.
Step 10. Upon completion, press Done to exit the installer. Then, use the desktop shortcut or select Start > Programs > Compuware > Workbench > Launch
Workbench to start the Compuware Workbench. Optionally, if no shortcut or program menu was requested, use Windows Explorer to navigate to the destination folder (specified in Install Folder), open the
Eclipse
subfolder and double-click workbench.exe
to run the Compuware Workbench.
Step 11. (for System Administrators) Create a copy of the media browser on a file share that users will have read access to. Note the name of the target folder; it will be needed for configuration and deployment. Be sure to copy all the files and directories and subdirectories from the media to the target file share—about
1GB of data. The media browser has a link near the bottom, Explore this
Compuware Workbench Installation
4-3
Media, which provides a Windows Explorer interface to enable copy and paste of the files on the media to the target file share of your choice.
Step 12. Configure defaults and prepare the deployment site as described in Chapter 5,
“Compuware Workbench Configurations”.
Installing Additional z/OS Product Plug-ins
During the initial installation of the Compuware Workbench client, you can select all or a subset of the available plug-ins to be installed. Any plug-in not part of the original installation can be added later by using the p2repo
directory on the media browser copy
(or from the p2 repository site created for Eclipse or IBM RDz installs, see“Installing
Compuware’s z/OS Product Plug-ins into Eclipse or IBM RDz” on page 4-3).
Note: The same release and maintenance level of the installed Compuware Workbench client must be used when installing additional plug-ins from a p2repo.
1. Use Help > Install New Software… to access the Install wizard.
2. In the Work with: pull-down menu, select the site that points to the p2repo directory. A list of plug-in categories appears.
3. Select only the desired additional plug-ins and then click Next. The Install Details dialog box appears.
4. Click Next, Review Licenses displays.
5. Click Accept and then click Finish to initiate the installation.
6. After the installation completes, click Restart Now.
IMPORTANT:
The Media Browser install should not be used to install additional z/OS Product
Plug-ins. Doing this may cause the Compuware Workbench to be reinstalled with only those selected plug-ins.
Installing Compuware’s z/OS Product Plug-ins into
Eclipse or IBM RDz
This section is a general explanation of the steps required to install individual z/OS
Product Plug-ins into an Eclipse-based environment. For the currently supported Eclipse or IBM RDz releases, please refer to the Compuware Workbench Release Notes.
Note: Beginning with release 4.0, Compuware Workbench implemented 64-bit support, which includes a 64-bit version of SlickEdit. The SlickEdit plug-in can now be installed into 64-bit versions of Eclipse and IBM RDz.
Note: The optional File-AID Data Privacy plug-in must be installed to the Compuware
Workbench client. Eclipse and IBM RDz environments are NOT supported.
Note: The sections contained within the Compuware Workbench Release Notes pertaining to individual plug-ins should be consulted before attempting to install any z/OS
Product plug-in into a particular version of Eclipse or IBM RDz.
Note: As a general practice, it is recommended that any previously installed releases of z/OS Product Plug-ins be uninstalled prior to installing the new releases of that plug-in. Due to an upgrade of the underlying Eclipse release level that
Compuware Workbench 5.0 is based, Workbench releases prior to 5.0 must be uninstalled before Workbench 5.0 can be installed. The Check for Updates
4-4
Compuware Workbench Installation Guide
facility should not be used. If you are migrating from an earlier release, see
Appendix C, “Migrating from Previous Versions”.
IMPORTANT:
Java JRE 1.7 build 10 or greater is required to run z/OS Product Plug-ins in an
Eclipse-based environment.
The outline of the process for installing z/OS Product Plug-ins is:
1. Create a central Compuware Workbench p2 Repository ( p2repo
) directory.
2. Use the Install New Software... option to Add a Software Site pointing to the central p2repo
directory.
3. Select and install the z/OS Product Plug-ins.
4. Restart Eclipse or IBM RDz.
System Administrator Installation Process Details:
Step 1. In the Media Browser Workstation tab, use the Create a p2 repository for
Eclipse and IBM RDz Users link to access the Create p2 repository wizard. In the wizard, click Browse to select a target directory location to contain a centrally accessible p2 repository for users to reference during installation.
Step 2. Once the target folder is specified, click the Create p2 Repository button to create the p2repo
directory. A message, “Copying Files Please Wait” will appear while the p2repo
directory is created. Copying files may take several minutes.
Once complete, the message “p2 repository created” displays.
Step 3. After the directory has been created to a centrally accessible file share, modify the file readme.htm
in the target directory to contain site specific configuration information for Host configuration and Compuware Mainframe product launch
plug-ins. See Chapter 12, “Deployment” for more details.
Step 4. If the optional SlickEdit support for Java (integration with JDT), C/C++
(integration with CDT), or PHP (integration with PDT) will be used, a separate directory should be created on the same centrally accessible file share. On the
Compuware Workbench media or in the extracted downloaded media, use
Windows Explorer to locate the p2RepoSEOpt
directory. Copy the entire directory to the central file share location.
User Installation Steps
Step 1. Select Help > Install New Software... The Installation dialog box appears.
Step 2. Use the Add... button to add a new site, pointing to the central p2repo directory on the share drive defined at your site. A list of the main z/OS Product
Plug-ins appears with selection checkboxes.
Step 3. Make sure the Group Items by Category checkbox is selected, and then select all the desired z/OS Product Plug-ins high-level categories (except File-AID Data
Privacy).
Step 4. Click Next to calculate the dependencies. Install Details appears.
Step 5. Click Next. Review Licenses appears
Step 6. Accept the License agreements and click Finish.
Step 7. If a Security Warning appears regarding unsigned content, click OK.
Step 8. If a Selection Needed dialog box appears regarding trusting certificates, click
Select All, then click OK.
Step 9. When asked to restart in the Software Updates dialog, click Restart Now.
Step 10. See Chapter 5, “Compuware Workbench Configurations” for instructions on
configuring the z/OS Product Plug-ins to communicate with the mainframe.
Compuware Workbench Installation
4-5
Step 11. If the optional SlickEdit support for Java (integration with JDT), C/C++
(integration with CDT), or PHP (integration with PDT) will be used, repeat the steps above, pointing to the separate p2RepoSEOpt site. When the SlickEdit
Optional Components category is displayed, expand and select the desired options.
Note: The SlickEdit core plug-in must be selected and installed during the initial z/OS
Product plug-in install prior to installing the optional SlickEdit plug-ins. The optional SlickEdit plug-ins should only be installed if the options are activated within the Eclipse environment. The Java plug-in can be installed into the
Compuware Workbench, if Java projects are used.
Note: SlickEdit recommends increasing the Java stack size above the default value for
Eclipse. This can be done by adding a vmarg
to Eclipse in the eclipse.ini
file.
SlickEdit recommends using 1024K: -Xss1024K. (See “Existing SlickEdit
Installations” on page 4-5 for further SlickEdit considerations.)
Existing SlickEdit Installations
For SlickEdit for Eclipse version 4.3 or less installed in a supported Eclipse-based IDE, the Compuware Editor powered by SlickEdit (version 4.3) will replace it upon installation of Host Explorer.
To use your existing SlickEdit preferences for the Compuware Editor powered by
SlickEdit:
1. Export the SlickEdit Preferences from your existing SlickEdit install through Window
> SlickEdit Preferences > Export/Import Preferences.
2. Install Host Explorer.
3. Import the SlickEdit Preferences to the
Host Services/My SlickEdit Core Config directory in the workspace using Window > SlickEdit Preferences > Export/Import
Preferences.
For SlickEdit for Eclipse versions greater than 4.3 previously installed to your supported
Eclipse IDE, Eclipse will not allow the installation of the Compuware Editor powered by
SlickEdit (version 4.3) shipped with Host Explorer. Any configurable SlickEdit
preferences from a newer version of SlickEdit should not be imported to the
Compuware Editor powered by SlickEdit shipped with Host Explorer.
Silent Installs
To set up the Compuware Workbench install to run silently, you need to create a response file. To run the installation and record a response file, execute the following command:
install -r
<path and file name of response file>
Example: install -r C:\temp\install.properties
The response file can be edited to change your installation folder. To use the response file in a silent install, execute the following command:
install -i silent -f
<path and file name of response file>
Example: install -i silent -f C:\temp\install.properties
Note: The install.exe
for installing the Compuware Workbench is on the media browser in the following location:
4-6
Compuware Workbench Installation Guide
\cpwr\Workbench\Windows\Disk1\InstData\VM
Note: When creating the response file, you may optionally specify an existing directory.
For example:
-r C:\temp
. If the directory exists, a file, installer.properties
, will be created in the directory containing the responses. Optionally, you may specify an existing file name of your choice within an existing directory
(Example:
-r C:\temp\wbresponse.file
)
Example 1
This is an example of the command for recording a response file when the Compuware
Workbench media has been copied to
C:\media
and a directory exists at
C:\silent
C:\Workbenchmedia\cpwr\Workbench\Windows\Disk1\InstData\VM\install.exe -r
C:\silent
Optionally, after installation and the response file is created, use any text editor to edit the
C:\silent\installer.properties
file to change the target directory name to something other than the name specified (default is
C:\Program Files\Compuware\Workbench
). The path will appear in the response file as follows:
#Choose Install Folder
#---------------------
USER_INSTALL_DIR=C:\\Program Files\\Compuware\\Workbench
Double backward slash
Example 2
This is an example of the command for executing the silent install:
C:\Workbenchmedia\cpwr\Workbench\Windows\Disk1\InstData\VM\install.exe -i silent -f C:\silent\installer.properties
Note: When deploying the Compuware Workbench you are directed to copy the
Compuware Workbench media to a file share, enabling users to install and configure their copy of the Compuware Workbench. In this case, consider also placing the response file on the central file share to be referenced by anyone with access.
For example, if drive letter T is mapped to a shared directory containing a copy of the
Compuware Workbench media, you might copy the
C:\silent\installer.properties
response file to
T:\installer.properties
. Then the command to perform a silent install might look like:
“T:\cpwr\Workbench\Windows\Disk1\InstData\VM\install.exe” -i silent -f T:\installer.properties
5-1
Chapter 5.
Compuware Workbench Configurations
Overview of Configuration and Deployment
Before using any of the available z/OS Product Plug-ins, some configuration is required.
It is recommended that the System Administrator use this installation guide to complete as many of the configuration steps as possible, then stage those configurations for endusers to install and use the z/OS Product Plug-ins.
Information about staging the configurations for end-users is discussed in Chapter 12,
Items to be configured initially are:
• (Required) Establish one or more HCI connection(s).
• (Only required for Abend-AID interface) Configure the Abend-AID Web Browser Interface plug-in.
• (Only required for iStrobe interface) Configure the iStrobe launcher plug-in.
• (Only required for Fault Analytics interface) Configure the Fault Analytics launcher plugin.
Step 1. HCI Connection and Configuring Hosts
To establish and validate an HCI Connection through the client
1. Open the Host Explorer perspective.
2. In the Host Explorer, right-click on Hosts. A context menu appears.
3. Select Configure from the context menu. The Preferences dialog box appears with the Host Explorer panel displayed.
4. Select Host Connection.
5. Click the Add… button to add a new host.
6. Fill-in the fields on the New Mainframe Connection dialog box and click OK. The
Host and Port are site-specific values based on the System Administrator's
completion of the Communications interface installation as described in Chapter 3,
“Communications to the Mainframe”. If you have multiple LPARs set up to support
Compuware Workbench (HCI port and CSS TP configured), use the Add... button to add each additional LPAR. Click OK when finished to close the Preferences dialog box.
7. Go to the Host Explorer perspective and right-click Hosts. Select Refresh from the context menu to view the newly added Host Connection(s).
8. Double-click a host to expand the tree to display the navigation paths (Endevor, File-
AID for DB2, File-AID for IMS, z/OS datasets, and z/OS UNIX files, etc.) When you attempt to access the host you may be asked to provide logon credentials.
Note: Navigation paths are dynamic and will appear (or not appear) based on the
CSS TP configuration. While z/OS datasets and z/OS UNIX files should always
5-2
Compuware Workbench Installation Guide
be present for a z/OS LPAR, Endevor, File-AID for DB2, and File-AID for IMS are dynamic.
Note: During login, checks are performed to validate the installation of Compuware
Products on the port. Results of these checks are written to the Console View.
These compatibility tests are provided to verify availability of Compuware
products needed to fully support the z/OS Product Plug-ins on this host port.
If File-AID mainframe products are not installed and licensed, Host Explorer navigation paths for File-AID for DB2 and/or File-AID for IMS may be suppressed, and the ability to invoke the File-AID Data Editor from a list of
MVS datasets or UNIX files may be disabled.
The File-AID Data Editor may limit some functionality if it detects that the version of File-AID is back level or does not contain the most current PTFs.
Similarly, the File-AID Dataset Search/Update option of the Search menu may not function. Use Window > View > Console to open the Console View if it is not already visible.
Note: The first time you launch Compuware Workbench and connect to a host, you may be prompted to Register as a user. Please complete the form and click
Register to allow Compuware Customer Support to know you are a
Compuware Workbench user in the event you need to contact them for assistance.
9. Select a system type (for example: z/OS Datasets), right-click and select Add Filter from the context menu. A system-type specific filter dialog box appears.
10. Enter the appropriate parameters in the filter dialog box (the wild card asterisk * is permitted).
11. Once the filter is defined, expand it to see a list of matching objects.
Step 2. Configure Compuware Mainframe Product Plug-ins (only for the Abend-AID, Fault Analytics, or iStrobe plug-in users)
1. Use Window > Preferences > Compuware to open the preferences list.
2. Select and configure each Compuware mainframe product plug-in used at your site.
Basic configuration consists of identifying the host or server and port and using the
Test Connection button to validate the connection: a. Abend-AID — if you have one or more hosts with Abend-AID Web Browser
Interface servers active, use this Preferences dialog box to configure each server in your site. b. iStrobe — if you have one or more iStrobe servers running in your site, use this preference dialog box to configure each server. For iStrobe, the Web site is a web directory where the iStrobe release is installed.
Note: An iStrobe server must be defined in order to use the JES Explorer Strobe
Add Active interface. c. Fault Analytics — if you have one or more Fault Analytics servers running in your site, use this Preferences dialog box to configure each server.
Step 3. Database Connections (for Data Privacy plug-in users)
When using the Data Privacy plug-in. All Host Connections and Database Connections must be defined on the Compuware Workbench Server (CWS). This is discussed in
Chapter 6, “File-AID Data Privacy”.
Compuware Workbench Configurations
5-3
One advantage to configuring connections on the CWS is those connections will appear in Host Explorer provided that the Compuware Workbench Server preference is set.
Compuware WorkbenchCompuware WorkbenchCompuware WorkbenchCompuware
WorkbenchCompuware WorkbenchCompuware WorkbenchCompuware Workbench
5-4
Compuware Workbench Installation Guide
6-1
Chapter 6.
File-AID Data Privacy
This chapter describes installation requirements to support the File-AID Data Privacy plug-in. Following instructions within this chapter are only required if you wish to use
File-AID Data Privacy.
It is recommended that you follow the installation steps outlined in Chapter 2,
“Installation Preparation and Checklist”. It provides explicit directions and references to
this chapter for the Mainframe and Non-Mainframe installations of File-AID Data
Note:
Mainframe Data Privacy is only supported on z/OS Release 1.10 or higher.
Figure 6-1 shows the interaction and dependencies between components required to
install and configure File-AID Data Privacy.
Figure 6-1. File-AID Data Privacy Installation and Configuration
Data Privacy Installation & Configuration
Operating System: z/OS Operating System: Windows
Install and Configure HCI
RCP Client
Configure Server
Location,
Host Connections
& Database Connections
File-AID/EX Client Execution Server and File-AID Rules Engine (FARE)
Start
File-AID Data Privacy
DBMSs
DB2 UDB
MS SQL Server
Oracle
Sybase
File-AID Single Installation
Configure :
File-AID/RDX, and/or
File-AID/IMS and/or
File-AID/DB2
Configure User Security
Create Data Privacy
Rules
Configure: dataprivacy.properties
file
(IP address or DNSname and port number)
Install FARE in z/OS UNIX
Configure :
File-AID/Data Solutions
(required)
Configure:
Conversion Specification z/OS UNIX
File-AID
Rules
Engine
(FARE)
Compuware
Server (CWS) installed on
Windows or Linux
(User Security
Determines
Access)
Configure FAIPADDR
(address of
Server)
Remote Execution Server and
LUW File-AID Rules Engine (FARE)
FAEXPATH
(location of z/OS UNIX
Rules Engine)
FAJOPTS
(Java options - z/OS UNIX)
Data Privacy
Rules
Repository
Derby Database
(default) and/or
DB2 UDB
MS SQL Server
Oracle
Security
Repository
Derby
Database
FAJPATH
(location of Java z/OS UNIX engine)
*You must install and have a license for the File-AID products you want to use with the File-AID Data Privacy plug-in.
6-2
Compuware Workbench Installation Guide
Note:
The File-AID Data Privacy plug-in is not supported in a native Eclipse IDE. You must install the Compuware Workbench client and Compuware Workbench
Server (CWS) in order to implement the File-AID Data Privacy plug-in.
Note:
Before performing the steps in this chapter, ensure you have completed
“Milestone II: Installing and Configuring the z/OS Product Plug-ins” on page 2-5
and installed the Compuware Workbench client.
Step 1. Install the Compuware Workbench Server
(CWS)
Note:
The Compuware Workbench Server is also referred to as the Data Privacy Server in the File-AID/EX product. Access to the CWS is controlled through Compuware
Distributed License Management (DLM) certificates. Before installing the server be sure to order Data Privacy licenses for the latest release of the CWS.
You will need to access the media containing the CWS installation. You can download the most current version of Windows or Linux version of the CWS installation files from the Fixes and Downloads section of the Compuware Workbench product pages on
FrontLine (http://go.compuware.com).
The Compuware Workbench Server is also provided on the File-AID/EX and File-AID
Distributed Components (FK) media image, downloaded with an RFN order, or on the
File-AID EP and Test Data Privacy EP (FJ) media.
During installation of the Compuware Workbench client, it is recommended that you copy the Compuware Workbench media to a central file share. Note that the CWS may be installed on the central file share machine. When selecting the machine on which to install the CWS, you should consider the number of Data Privacy users and then make sure the machine has sufficient capacity in terms of CPU cycles, processor speed, and disk space. In general, Data Privacy has minimal CPU requirements, but does require about
1GB of disk space to contain the CWS software and the default Derby databases.
The CWS communicates over the network using the following default open TCP ports:
3081, 4082, 4180, and 5180. Make sure there are no conflicts with these ports on the selected machine. If needed, you can override the default ports, after installation, by
using a provided utility as described in “Changing Compuware Workbench Server Port
Assignments” on page E-1. In addition, when installing the CWS, you should be logged
in as the
Administrator
for the selected server. CWS uses, by default, port 4082 to handle notification messages. This port is dynamic and is controlled by the Compuware
Workbench client's Notifications callback port preference: Window > Preferences >
Compuware > Notifications. If needed, you can establish a different master preference port number for this function prior to deployment of the master configurations. (see
1. Select a machine to run the CWS and insert or locate the distribution media or the electronic download of the CWS installation files from FrontLine. Run setup.exe from the media. The media browser appears.
2. When installing from the distribution media do the following: a. Click the Server tab.
b. To install the CWS in Windows, c lick the Install Compuware Workbench
Server on Windows link.
3. If installing the CWS using install files downloaded from FrontLine, unzip the selfextracting ZIP file to a directory of your choice. For Windows, open the extracted
Windows subfolder and run update.bat
. (For Linux see “Install the Compuware
Workbench Server to Linux” on page E-3).
4. The InstallAnywhere dialog box appears.
5. Read the introductory text and click Next.
File-AID Data Privacy
6-3
6. Read the license agreement and select the I accept the terms of the License
Agreement button. Click Next.
7. Choose a destination folder to install the CWS or accept the default value
C:\Program Files\Compuware\ Server or
C:\Program Files(x86)\Compuware\
Server
. Click Next. Installation setup information is displayed.
8. Select the databases with which you intend to work.
IMPORTANT: Check all database types that you might access at your site. For each item you select, the installation process automatically installs the appropriate JDBC driver. However, for DB2, you are responsible for providing the location of the folder containing the driver ( db2jcc.jar
) and the corresponding appropriate licenses for accessing DB2 for LUW and/or z/OS.
Note:
If you do not choose a database type at install time and later wish to configure a connection to that type of database, you will need to use the
Server Configuration utility as described in “Adding Compuware Workbench
Server Database Drivers” on page E-2.
9. If you select Oracle, you will be prompted to accept the Oracle license agreement.
10. Confirm the setup information and click Install. Once installed, click Done to dismiss the InstallAnywhere dialog box. The CWS begins running using port 3081 for secure Compuware Workbench client access, port 4180 for Data Privacy execution, and port 5180 for File-AID/Data Solutions interface.
If you need to change the
default CWS ports for any reason, see “Changing Compuware Workbench Server Port
11. During installation, the Distributed License Manager (DLM) is installed with a temporary license for the CWS. Use the DLM administration tool to activate your
permanent CWS license certificate.
Refer to the Distributed License Management Installation Guide for information. To access
DLM, click Start > All Programs > Compuware > Distributed License
Management.
Note: DLM installations default to the C: drive in Windows. Contact Compuware
Support if you need to install DLM to a different drive letter.
12. Validate that the service is running by using a web browser to view the URL: http://hostname:4180/versions where hostname is either
localhost
or the machine name or IP address where the server is installed. The resulting web page should display with a list of executing bundles.
13. Configure the CWS in Compuware Workbench a. Run the Compuware Workbench client.
b. Access Window > Preferences > Compuware > Server to establish the location and port of the installed CWS. Use the Test Connection button in the Preference dialog box to verify that the address is correct.
Note: The Compuware Workbench Server preference is only present when the Data
Privacy plug-in has been installed in Compuware Workbench.
Note: The default Compuware Workbench Server port to connect to is 3081. For example: https://cwsserver:3081
.
Be sure to include the ‘s’ in https for your connection string.
Note: Once a connection to the CWS is established, the Host Connections, as well as
Database Connections, must be defined on the Server. When you right-click on Hosts in the Host Explorer view and select Configure, you may choose to define either Local Host Connections or Host Connections on Server. Host
Connections (and Database Connections) on the server are available to all
6-4
Compuware Workbench Installation Guide
users connected to the Compuware Workbench Server and do not require individual configuration or preferences to import. All Host and Database
Connections are managed by the Compuware Workbench Server
Administrator (default userID: cwadmin
and password: cwadmin
).
IMPORTANT: Host connections must be defined on the CWS for File-AID
Data Privacy.
Note:
In order to use the CWS, users must install the Data Privacy plug-in.
Note:
To access metadata for Distributed RDBMS databases in File-AID Data Privacy, you must first configure a connection to each desired instance using the
Configure facility in Host Explorer. Refer to the online help for the Host Explorer
User Guide for details. In general, the procedure to configure a remote host database is: a. In Host Explorer, right-click Hosts and select Configure, then choose Host
Connections on Server from the cascade menu list.
b. Supply Administrator credentials (default is userid: cwadmin
, password: cwadmin
).
(You should consider changing the password to limit access to this facility to server administrators only.) c. Use the JDBC or Database Configurations notebook tab to Add... a new Database. d. Complete the connection information in the Database Connection dialog box.
Click OK.
Step 2. Install File-AID/EX
Perform this step only if you plan on privatizing distributed RDBMS databases. File-
AID/EX is provided for RFN orders via a download of the File-AID/EX and File-AID
Distributed Components media (FK) or on the File-AID EP and Test Data Privacy EP media (FJ).
1. File-AID/EX Windows Client
A copy of the File-AID/EX client will need to be installed for each user machine.
Install File-AID/EX 5.3 or higher. Use the Windows Products tab of the media containing File-AID/EX to select 32-bit or 64-bit version of File-AID/EX client. An
Execution Server and the File-AID Rules Engine are installed by default with the installation of the File-AID/EX client.
For more information refer to the File-AID/EX Installation Guide provided with the distribution media or on Compuware Go/FrontLine.
2. File-AID/EX Server Edition (if licensed).
The server edition allows units of File-AID/EX work to be routed to remote servers for execution close to the actual data source. Installation of this plug-in requires that a
File-AID/EX execution engine and a File-AID File-AID Rules Engine (FARE) be installed on each server where File-AID work is to be routed. a. For Unix servers, use the UNIX tab of the media containing File-AID/EX, to access files needed to install Execution Servers for AIX, HP-UX, Linux, or Solaris.
During installation of an Execution Server for UNIX, to automatically install
FARE, be sure to answer yes (Y) to the question to install the File-AID Rules
Engine. b. For Windows Servers, use the Windows Products tab of the File-AID/EX media to select 32-bit or 64-bit version of File-AID/EX client. Optionally, de-select the File-
AID/EX client and Repository components and ensure Execution Server and
Data Privacy are selected.
File-AID Data Privacy
6-5
By de-selecting the File-AID/EX client, the File-AID/EX Windows Execution
Server installs as a Windows service, which automatically starts and runs when the server is booted.
Once your Execution Server is installed and started, launch File-AID/EX Homebase and add this Execution Server to the list of valid Execution Servers. For more information refer to the File-AID/EX Installation Guide provided with the File-AID/EX distribution media or at Compuware Go/FrontLine.
3. Configure File-AID/EX for Dynamic Privacy Rules.
In order to enable File-AID/EX to specify and execute the Dynamic Privacy Rules (as defined in disguise projects created by File-AID Data Privacy), you must specify the
CWS location in the
DataPrivacy.properties
file located in your
Compuware/<File-
AID product name>/cfg
directory.
– For File-AID/EX 5.3 or higher: Start Homebase and select Tools > Dynamic Data
Privacy option to access the Server Configuration dialog box. In the Server
Configuration dialog box, fill in the DNS name or IP address of the CWS (a.k.a.
Data Privacy Server) and the port number (the default port number is 4180).
The Server Configuration dialog box can be used to configure all Execution
Servers registered to the repository.
It is recommended that a copy of the modified
DataPrivacy.properties
file be placed in a central file share so that all users of File-AID/EX that wish to use the new File-AID Data Privacy dynamic rules can easily update their installed version of File-AID/EX.
Note:
The modification to the
DataPrivacy.properties
files must be made to all installations of the File-AID/EX Execution Servers.
4. Perform this step only if planning on disguising distributed DBMS databases
where the Data Privacy project references z/OS files containing shared Translate
Tables. If you are not sure about whether you need to install the File-AID/EX
Enterprise Edition, defer this step until the use of the Data Privacy plug-in
requires it.
The File-AID/EX Enterprise edition allows connectivity to mainframe data. Ensure
File-AID/EX Enterprise Edition is installed and configured in z/OS.
Note:
File-AID 10.1 or higher includes the File-AID/EX Enterprise Edition's MVS Access modules. Installation and configuration of File-AID/EX Enterprise Edition's MVS
Access modules is described in the File-AID Single Install Image Installation and
Configuration Guide provided on Compuware GO/FrontLine or on the File-AID EP and Test Data Privacy EP media.
Step 3. Install the File-AID Rules Engine (FARE) on z/OS
UNIX
Perform this Step 3. only if you plan to use the File-AID Data Privacy plug-in to disguise z/OS data using the Compuware’s File-AID products (File-AID/Data
Solutions, etc.) running on z/OS. A z/OS UNIX console tool (for example, TELNET or
OMVS) must be used to install the FARE. Follow these steps to install the FARE in z/OS UNIX on a target LPAR.
Note:
If using OMVS as a console to z/OS UNIX be sure your TSO region size is large enough to run Java. Also, note the FARE requires about 50MB of space — be sure you have sufficient space in the upload and target directories to contain the files.
Note:
Installing the FARE in z/OS UNIX requires knowledge of z/OS UNIX. Your user ID must have a default OMVS segment (or something equivalent) specifying a valid non-zero z/OS UNIX user ID (UID), home directory, and shell command. You
6-6
Compuware Workbench Installation Guide
should have authority to write to at least two directories (install files directory and target FARE files directory), each with sufficient space to contain the installation files or the installed software. Total install time for installing the
FARE should be less than 1 hour.
1. Run setup.exe
on the File-AID Distributed Components (FK) media image downloaded from an RFN order, or from the File-AID EP and Test Data Privacy EP (FJ) media.
Note: The current version of the z/OS Unix FARE is also available as a download from the Fixes and Downloads section of the Compuware Workbench product page on FrontLine. You must synchronize the version of the FARE with
the version of the Compuware Workbench client, Data Privacy plug-in, and also
the CWS.
2. Select the USS tab in the media browser.
3. Use the built in FTP facility to transfer the FARE installer files to z/OS UNIX. Supply the host, userid, password, and the target path name of an existing z/OS UNIX directory. Select the Upload Files to the Mainframe button to initiate the FTP
transfer.
For example: host LP01 directory
/u/user/userid
4. In z/OS UNIX, locate the path to a current Java Virtual Machine (JVM). The File-AID
Rules Engine requires a minimum of Java JRE 1.7 build 10 or more current. (For example:
/usr/lpp/java/java6
). For validation purposes, execute the shell command:
[path]/bin/java -version
(where
[path]
is the path name to the JVM — for example:
/usr/lpp/java/java6/bin/java -version
).
5. Edit the uploaded installfare.sh
file to set the JAVA_HOME environment variable to point to the JVM you located [path].
6. Execute the installer by issuing the shell command: sh installfare.sh
7. Accept the default installation destination path (
/opt/Compuware/fare
) or specify a path to which you have write access and has at least 50MB of free space.
Note: The target directory must not be the same directory where you uploaded installfare.sh
.
Note: Be sure to save the name of the target directory for the FARE and the path name to the JVM — they will be needed to configure File-AID/Data Solutions to enable z/OS disguise executions.
8. Specify whether you will be working with Oracle databases. If you select Yes, you will be asked to accept the Oracle license agreement.
9. Specify whether you will be working with IBM DB2 databases. If you select Yes, you will be asked to supply the pathname to the folder containing IBM DB2 JDBC driver file db2jcc.jar
and the corresponding appropriate license files for DB2 UDB on z/OS.
Step 4. Install File-AID/Data Solutions
1. For File-AID Data Solutions release 10.1 or higher:
Use configuration task 2 (DB2/IMS/DPR Environment) and select Option 3 (Data
Privacy) to configure Data Solutions customization module XVJOPDPR to work with
File-AID Data Privacy and to provide information about the following:
– CWS location (machine name or IP address)
– CWS port assignments
File-AID Data Privacy
6-7
– Mainframe (z/OS UNIX) FARE (Java path and installation directory)
For more information refer to the File-AID Single Install Image Installation and
Customization Guide.
For File-AID/Data Solutions 4.4:
Be sure to use the Installation Customization Option 5 - Data Privacy to provide
Privacy configuration information. Also, be sure to run Customization task 7, DATA
PRIVACY - Configure Dynamic Privacy Rules (DPR), to request that File-AID/Data
Solutions generate an additional dataset (JAVAINFO). This dataset contains values you established, which are used to invoke the FARE whenever a disguise execution of a File-AID Data Privacy plug-in project is requested from the mainframe (z/OS) File-
AID products.
For more information refer to the File-AID/Data Solutions Installation Guide provided with the product media.
2. Follow the Installation Verification for File-AID Data Privacy process described in the installation guide to verify operation of File-AID Data Solutions.
Step 5. Install File-AID/Common Components
1. For File-AID 10.1 or higher: File-AID/Common Components is included with the
File-AID single install image installation; be sure to include just the File-AID customization library (CXVJLOAD) and the authorized load library (SXVJAUTH) in
the STEPLIB concatenation of the STASK as described in “Step 8. Copy the Generated
STASK and SSAS PROCS to PROCLIB” on page 3-21.
2. For File-AID products prior to 10.1: Install File-AID/Common Components 2.1.
File-AID/Common Components is distributed on the File-AID EP media and also on the File-AID Data Privacy EP media or RFN distribution. Installation documentation is provided on the media or on Compuware Go/FrontLine.
AID/Eclipse and File-AID Data Privacy” on page 7-1.)
Note: File-AID/Common Components is also required for File-AID Data Editor. Skip this step if File-AID/Common Components has already been installed for
File-AID Data Editor.
Note: Be sure to include the File-AID/Common Components Authorized load libraries (MXVJnnn.SXVJAUTH, and MXVJnnn.CXVJAUTH) in the STEPLIB
concatenation of the STASK as described in “Step 8. Copy the Generated
STASK and SSAS PROCS to PROCLIB” on page 3-21.
Step 6. Install Additional File-AID Mainframe Products as Needed
Note:
For File-AID 10.1 or higher, all of the File-AID products are automatically installed. User access to these File-AID products is controlled by licensing with
Compuware.
• File-AID/RDX 5.0 and higher is distributed on the File-AID Data Privacy EP media or
RFN order. Installation documentation is provided on the media.
• File-AID for IMS 7.7and higher is provided on the File-AID EP media or RFN order.
• File-AID for DB2 6.3 and higher is provided on the File-AID EP media or RFN order.
• Apply all current maintenance to the z/OS versions of File-AID family of applications
(used to disguise data using the new File-AID Data Privacy facility).
6-8
Compuware Workbench Installation Guide
Step 7. Data Privacy Security Configuration
Note:
This step is typically performed by a Data Privacy Administrator. But this Step should be started in order to initially define a Data Privacy Administrator user for the purpose of validating the installation of Data Privacy in Compuware
Workbench.
In File-AID Data Privacy, users must be assigned Data Privacy roles. This step discusses how these roles are used and how they are configured. After the installation of Data
Privacy was completed, full configuration would be typically done by users designated with the role of Data Privacy Administrators.
No specific login is required to access the Data Privacy perspective. When the File-AID
Data Privacy perspective is selected, the currently active userid determines the Data
Privacy role assignment. All roles are assigned at the server level and all repositories within the same server will have the same role assignments.
Note:
The following roles, and additional roles you create for your site, prevent users from accessing information that is not available for their role. Information on the mainframe is protected by whatever security the mainframe provides (such as
RACF). This means that a Compuware Workbench user cannot access any information on the mainframe that cannot be accessed when logging directly to the mainframe.
Role Definitions
Table 6-1.
File-AID Data Privacy Functionality by Role
Data Privacy Functionality DP Admin
Project
Admin
Global
Resource
Admin
SME
Privacy
Auditor
(Only view)
Assign Roles
Create Project
Update Project
Delete Project
•
•
•
•
•
•
•
(delete only by owner)
Change the Project owner
Add Project Metadata
Manage repositories
Create Data Element
Update Data Element
Delete Data Element
Create Rules
Update Rules
Delete Rules
Create rule actions
Update rule actions
Delete Rule actions
Rule Variables
Import global Data Elements
Import global Rules
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
File-AID Data Privacy
6-9
Table 6-1.
File-AID Data Privacy Functionality by Role
Data Privacy Functionality DP Admin
Project
Admin
Expression builder
Update Global projects
Update Global Data Element
Update Global Rules
Manage Translate tables
Manage Encryption keys
Manage Credentials
Manage Custom Functions
Create Data Identifiers
Update Data Identifiers
Delete Data Identifiers
View Coverage
Run Coverage Analysis
Coverage Report
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Global
Resource
Admin
•
•
•
•
•
•
•
SME
•
•
•
•
•
•
•
Privacy
Auditor
(Only view)
•
•
•
The following is a description of the default roles provided with File-AID Data Privacy:
Data Privacy Administrator
Different roles will have access to different functions within File-AID Data Privacy. The
Data Privacy Administrator role has the highest level of authorization giving complete access to all functions within Data Privacy.
When Data Privacy is installed, the role of Data Privacy Administrator is assigned to a temporary default ID. This administrator-level default ID must be used the first time Data
Privacy is accessed in order to assign actual userids to Data Privacy roles, including other
Data Privacy Administrators. Once another userid is given the role of Data Privacy
Administrator, the temporary default ID can be deleted. File-AID Data Privacy requires at
least one userid assigned to the Data Privacy Administrator role. The Data Privacy Administrator is the only role authorized to manage repositories, set preferences and other definitions that affect the entire Data Privacy installation.
Data Privacy Auditor
The Data Privacy Auditor has the authority to browse and report on all data within all projects. The Data Privacy Auditor cannot change any data.
Data Privacy Global Resource Administrator
The Data Privacy Global Resource Administrator is responsible for defining and managing their sources that are shared by all data privacy projects. This includes global data elements, global rules, managed translation tables, encryption keys, credentials, and custom functions.
Data Privacy Project Administrator
The Data Privacy Project Administrator is responsible for creating projects and managing the definition of privacy within the project. This includes the definition of data elements and rules. Data Privacy Project Administrators can import global definitions into their projects.
6-10
Compuware Workbench Installation Guide
Any user assigned to the Data Privacy Project Administrator role is authorized to browse all projects, but they must have the project authorized to be able to edit the project.
Because Data Privacy Project Administrators create projects, this role acts as both the project creator and the project owner.
Any Data Privacy Project Administrator can update the project, but only the product owner can delete the project.
Data Privacy SME (Subject Matter Expert)
A userid assigned the Data Privacy SME role should have knowledge of the application data and thus, is able to create the data element definitions by adding data identifiers to the data elements defined by the project administrator. Users in this role cannot create new data elements. Subject matter experts can use their application knowledge and search the metadata to properly identify the data for each data element.
Map Security Roles
Role definition is the process of mapping userids and groups to the roles defined within the product. Each role is associated with a predefined set of permissions within the product functionality.
The Compuware Workbench Server (CWS) installation includes the installation of a
Derby database for the security repository. The CWS acts as the roles server, and the mapping of users and groups to the roles used by the product are stored in the security repository.
When any functionality is requested using Data Privacy, the user authorizations are checked to verify that they have the appropriate role to perform the requested function.
A user must have at least one Data Privacy role to be allowed to open any project in the
Data Privacy application. Data Privacy authorizations are specific to the server being used.
Configure Security
Security is configured from within Compuware Workbench. If you have the proper authority, you can set up security from within the Data Privacy perspective.
Following are the steps that allow you to set up your site's default authentication, and manage users, groups, and role mapping.
1. From within Compuware Workbench, you may start by selecting Data Privacy from the Compuware menu. The Data Privacy perspective may also be opened from the
Windows menu, select Open Perspective > File-AID Data Privacy.
Note: When you start Data Privacy for the first time, you will receive an error message "User has no roles". You may ignore this message at this time.
2. Select Configure > Manage Security. Supply Administrator credentials with default userid: cwsecadmin and password: cwsecadmin
. (You should consider changing the password, to limit access to this facility to Data Privacy Administrators only.) The
Security Editor Authentication view appears. There are several tabs at the bottom of the screen allowing you to select the different options.
3. Authentication is preselected. All fields are filled with defaults provided at installation time, and are disabled and cannot be modified.
4. Select the User Management tab. The User Management view appears. The default user names, and any users who have been added since installation, appear in the
User Name list.
a. To add a new user, click Add. The Add Users dialog box appears. Enter a domain name and userid in the User Name field in uppercase. The domain name should be followed by a backslash ‘\’ when preceding the userid (for example:
File-AID Data Privacy
6-11
DOMAINNAME\MYUSERID
). You may optionally supply a password for this user. It is not required or used at this time. Instead, Windows authentication is used to validate users by LAN ID. Then click OK. The user is now added to the list. Repeat this step until you have added all of the desired users.
b. To modify a userid or password, select a user and click Edit. Make your changes and click OK.
c. To delete a user, select the user and click Remove.
5. Select the Group Management tab. The Group Management view appears. The default groups, and any groups that have been added since installation, appear in the
Group Name list.
a. To modify a group, select a group and click Edit. The group name cannot be changed, but you can add users to or delete users from the group. Make your changes and click OK.
b. To delete a group, select the group and click Remove.
Note:
If you are adding multiple users to a new or existing group, you can click Apply periodically to save your selections without closing and reopening the dialog box.
c. To add a new group, click Add. The Add Groups dialog box appears. Enter a group name in the Group Name field, and move the users you want to add to the group from the Available Users column to the Selected Users column. Then click OK.
Note:
Default Groups are supplied with the Data Privacy plug-in and should be sufficient to control access to Data Privacy plug-ins. In most cases you do not need to add a new Group.
6. Select the Role Mapping tab. The Role Mapping view appears. The default mapped roles, and any roles that have been added since installation, appear in the Name list.
a. To map a group to a role, select one of the Application Roles from the list and click Map Groups. The Group Selection dialog box appears. Select a group name from the list of groups. If you have many groups, you can search for the desired group, Click Search. After you have selected your group, click OK. That group will appear in the role mapping list for that role. Repeat this step until you have mapped all of the desired roles.
b. To map a user to a role, select one of the Application Roles from the list and click
Map Users. The User Selection dialog box appears. c. Select a userid from the list of available users. If you have many userIDs, you can search for the desired user, click Search. After you have selected your user, click
OK. That userid will appear in the roll mapping list for that role. Repeat this step until you have mapped all of the desired roles.
d. To delete a user or group mapping, select the user or group and click Remove.
Note:
It is highly recommended to assign at least one user to the Data Privacy
Administrator role. That user will be able to access this Manage Security utility, without having to provide any special logon ID or password, whenever they are using the Data Privacy plug-in.
Data Privacy Installation Flowcharts
Communication
Milestone 1
Establish
Communication with
LPAR
(Per LPAR)
HCI Configured to support
DevEnterprise?
yes
After configuring a new HCI for the RCP, if you want to run a single HCI instance see Appendix I no
Install/Update
HCI, CSS, and
LMS
ECC EP Media or RFN
HCI installed and current?
yes no
Install/Update HCI
CSS installed and current?
yes no
Install/Update CSS
LMS installed
and current?
yes
Install License
Certificates for
Compuware
Products on this
LPAR as needed no
Install/Update LMS
Communications
Established from
prior release?
yes
ECC Installation
Guide
Installation Guide no
Configure HCI and
CSS TP with Host
Communication
Configuration
Facility (HCCF)
Review Migration
Considerations for
HCI and the CSS TP
in Appendix C
Install PROCS, Start
HCI, Verify Host
Communication
Compuware
RCP Client
Compuware Workbench Client
Milestone II
RCP Client
New Install
Eclipse or IBM RDz or Upgrade?
Upgrade
New
Stage new p2repo from media to update site location.
Existing Eclipse
RDz or Compuware’s
RCP?
Eclipse or IBM RDz
Prepare p2
Repository
Compuware Workbench-only (required for Data Privacy)
Copy media to
Central File Share
Install all or desired plug-ins
Run setup.exe and install Compuware’s RCP
Client (use Custom or Data Privacy to include Data Privacy plug-in)
Install updates
Configure Host(s)
Configure Abend-AID and iStrobe if desired
Verify Basic
Communications with Host Explorer
End of RCP Client
Installation
Data Privacy
MIlestone III
Data Privacy
Compuware Server
(Data Privacy Server)
Install Compuware
Server from the distribution media or
FrontLine download
DLM Administration install permanent
CWS license
(trial license will run for
30 days)
Run RCP Client, set
Compuware Preferences,
Server DNS name or IP address (default port 3081), reconfigure hosts on server
File-AID EP Media
or RFN
FA/EX Installation
Guide
Distributed Data in Scope?
no yes
Per User
Install File-AID/EX with local Execution
Server and FARE plus remote Execution Servers
(as needed)
Set up License and also
Configure Data
Privacy Server
Compuware Server
Windows or Linux
Install FARE in z/OS UNIX
Install
File-AID
Data Solutions configured and current?
yes no
Install/Update/Configure/License
Data Solutions
To
File-AID
Configure
DPR (Server and FARE), verify
File-AID Products
File-AID
File-AID EP and Data Privacy EP Media or RFN
Is DB2 Data in
Scope?
no yes
Install/Update/
Configure/License
File-AID for DB2
Is IMS Data in
Scope?
no yes
Install/Update/
Configure/License
File-AID for IMS
Is DB2 or MVS
Data in Scope no yes
Install/Update/
Configure/License
File-AID/RDX
Are mainframe
VSAM/Seq translate tables to be used in
Distributed Data projects?
no yes
Install/Update/
Configure/License
File-AID/EX
Enterprise Edition
MVS Access
Modules
(By Data Privacy
Admin)
Configure Security and User Roles
End Data Privacy
Milestone
6-16
Compuware Workbench Installation Guide
Deployment
Milestone IX
Deployment
Export preferences to preferences directory on Central
File Share or p2repo site
Optional
(Compuware- RCP only)
Export locations of update site to sites directory on Central file share
Update defaults in
readme.htm
Notify users where to find the central file share or Eclipse p2repo site and to use the
readme.htm
to install the
RCP (or plug-ins) and import preferences
(End users)
Install and Import
Configurations
End of Milestone IX
Deployment
7-1
Chapter 7.
File-AID Product Installations and Configurations
Support of File-AID/Eclipse and File-AID Data Privacy
The information discussed in this section is only applicable if your site is planning to use the File-AID/Eclipse and/or File-AID Data Privacy.
For File-AID/Eclipse (includes File-AID Data Editor and File-AID Search/Update), be sure to install File-AID/MVS 9.4 or higher, and File-AID Common Components 2.1 or higher, both with all current maintenance, to support search and browse/edit of z/OS files. Data
Editor also requires the installation of File-AID for DB2 6.3 or higher, with all current maintenance, to support browse/edit of DB2 tables/views. To support browse/edit of IMS databases, be sure to install File-AID for IMS Release 7.7 or higher with all current maintenance.
For File-AID Data Privacy, make sure you have File-AID/Data Solutions Release 4.4 or higher with all current maintenance installed.
Also, if you plan to disguise distributed
RDBMS databases you will need to install File-AID/EX 5.3 or higher. For z/OS disguise projects you may optionally install File-AID/RDX, and/or File-AID for DB2, and/or File-
AID for IMS. Refer to Chapter 6, “File-AID Data Privacy” for additional details.
For File-AID Data Privacy and File-AID/Eclipse, be sure File-AID/Common Components
Release 2.1 or File-AID 10.1 or higher with all current maintenance is installed.
File-AID products are distributed on the File-AID EP and Data Privacy EP software media or via RFN order. Installation documentation is also provided on the media or
Compuware GO/FrontLine web site. For installation procedures, refer to the File-AID
Single Install Image Installation and Configuration Guide.
Step 1. Ensure Required Currency of the Pertinent File-AID Products
On the home page of the Compuware Workbench product on Compuware
Go/FrontLine (
http://go.compuware.com
) use the link: Compuware
Workbench Companion Product Requirements to verify the necessary release and maintenance levels of the File-AID products required to support the File-
AID Data Editor:
• File-AID/Common Components (only needed when using File-AID products prior to 10.1. Is installed automatically in File-AID 10.1 or higher).
• File-AID/MVS
• File-AID for DB2
• File-AID for IMS
• Optionally, you may use the Compuware Maintenance Utility to verify your
PTF levels. See Appendix H, “Compuware Maintenance Utility”.
Only when using the pre-10.1 File-AID EP Media browser for implementing either the File-AID/Eclipse plug-ins or File-AID Data Privacy plug-in
1
, you may create the File-AID Combination library WXVJAUTH using the Compuware File-
AID EP Customization Facility, View/Copy Datasets for this Install. If you create the combination library, you can use it as the only File-AID library for the
STASK JCL as described in “Step 8. Copy the Generated STASK and SSAS PROCS to
PROCLIB” on page 3-21. Be sure to assign universal READ access and APF
Authorize the dataset.
1. Implementing File-AID/Eclipse and File-AID Data Privacy should be done only after installing and customizing your site’s File-AID products: File-AID/MVS, File-AID for DB2, or File-AID for IMS.
7-2
Compuware Workbench Installation Guide
Instructions for using the Compuware pre-10.1 File-AID EP Customization
Facility are provided in pre-10.1 File-AID product installation guides.
8-1
Chapter 8.
Xpediter/Eclipse Installation and Configuration
The information in this chapter is only applicable if your site is planning to use the
Xpediter/Eclipse plug-in. This chapter contains important information that can help you install Compuware products required in support of Xpediter/Eclipse.
Support for Debugging Batch, IMS and Stored
Procedures
What you will need
• The name of the CSS Compile Information Table library (SLCXTABL). This dataset is created during the customization of CSS as described in “Step 4 (Create Compile
Information Table)” in the CSS Customization chapter of the Enterprise Common
Components Installation and Customization Guide.
Step 1.Ensure necessary currency of Xpediter/TSO
On the home page of the Compuware Workbench product from Go/FrontLine
(http://go.compuware.com) use the Compuware Workbench Companion
Product Requirements link to verify that the release and maintenance level of
Xpediter/TSO and Xpediter/IMS you are working with supports the
Xpediter/Eclipse plug-in for Compuware Workbench.
Step 2.Ensure Xpediter/TSO Multi-Batch Facility is installed
Xpediter/Eclipse requires the Xpediter/TSO Multi-Batch Facility. Consult the
Xpediter/TSO and /IMS Installation Guide for details on installing this feature.
Step 3.Create the Compuware Shared Profile Dataset
A sample JCL member named CSPFINIT is supplied in the Compuware Shared
Services (CSS) samples library (COMPWARE.MLCXNNN.SLCXCNTL). Edit the member and make the following changes: a. Supply a job card.
b. Choose a name for the CSPF dataset and change the name in five locations in the
JCL member.
c. In JCL Step 2, specify the dsname of the Compuware Shared Services loadlib
(SLCXLOAD).
d. Update the SYSIN DD control statements. The dataset name after the ISPTABL= control parameter should be set to the dataset name of the Compuware Shared
Services table library dataset (SLCXTABL). ISPFTABL — specify the CSS dataset name for the SLCXTABL dataset.
e. Submit the job.
Note: The security profile for the CSPF dataset should be set up to allow all users
READ access.
Step 4.Populate the Compuware Shared Profile Dataset
The Compuware Shared Profile was created in the previous step. Now it must be populated with the information required to interface with Xpediter/TSO. This is
8-2
Compuware Workbench Installation Guide
done by customizing and running the JCL in SLXTINST dataset member JCLCSPF as described below.
Customizing and Running JCLCSPF
Member JCLCSPF must be customized and run as follows: a. Change YOUR.CSPF.FILE to the name of your Compuware Shared Profile Facility dataset.
b. Change CPWR.XT to the high-level qualifier of your Xpediter/TSO libraries.
c. Change CPWR.XV to the high-level qualifier of your Xpediter/Code Coverage libraries.
d. Change CPWR.CX to the high-level qualifier of your Compuware Shared Services
(CSS) libraries.
e. Update the SYSIN DD control statements as follows:
• CXLIB - Specify your Compuware Shared Services load library dataset name.
• XTSOLIB - Specify your Xpediter/TSO load library dataset name.
• COVERLIB - Specify your Xpediter/Code Coverage load library dataset name
(optional).
• XTSWSLIB - Specify your Xpediter/TSO site-wide script library dataset name
(optional).
Note: The information required for the site-wide script file was specified during
Xpediter/TSO installation. That information will be automatically extracted and applied to the CSPF. If you would like to override the value specified during installation, you may do so by deleting the asterisk in column 1 and specifying the value on the XTSWSLIB control card.
f. The information required for the IMSMPP control cards was specified during
Xpediter/TSO and Xpediter/IMS installation. That information will be automatically extracted and applied to the CSPF. If you would like to override the values specified during installation, you may do so by deleting the asterisk in column 1 and supplying values for the IMSMPP control cards. The keywords for the IMSMPP control card are
• MPP= Maximum number of concurrent MPP tests allowed within an IMS subsystem.
• IFP=000 (reserved for future use).
• BMP=000 (reserved for future use).
• TOT= Maximum number of all types of concurrent tests (MPP, IFP, BMP) allowed within an IMS subsystem.
• CLS= Specifies an IMS message class that is reserved for Xpediter/TSO’s use.
There can be up to 50 of these IMSMPP CLS control cards.
g. Submit the job. It should complete with a return code of 0. If you receive a nonzero return code, refer to the Xpediter/TSO and Xpediter/IMS Messages and Codes manual.
Step 5.Update the TP Configuration with the name of the CSPF
Edit the TP Configuration member (default CXTP01) in the configuration load library
(COMPWARE.CX.CONFIG). Revise the CSPF statement to point to the dataset name
of the CSPF dataset you created in step 3 and populated in step 4. (For more
information see “Code the CSPF Statement” on page F-6)
Step 6.Make sure the TP Configuration TSO statements are specified
Edit the TP Configuration member (default CXTP01) in the configuration load library
(COMPWARE.CX.CONFIG).
Xpediter/Eclipse Installation and Configuration
8-3
IMPORTANT: If no TSO debugging support is desired or available, do not code any TSO statements.
Code the TSO statement. The format of the TSO statement is:
TSO Sysname Applid Logmode LPAR Name
Sysname
Specify a unique name to identify this connection to the Xpediter/Eclipse user.
This 20-character field can contain any valid characters. The name should be descriptive so the user can identify the connection point. Typically, an LPAR name or operating system ID plus other descriptive information is used. The sysname is presented to the Xpediter/Eclipse user as a potential connection point.
Applid
Specify the VTAM application ID (APPL) that is used for the primary TCAS address space on your system. This is the same APPL used by typical users logging on to TSO via a 3270 display. Typically, only one TSO statement is coded, but if your VTAM network is set up with the proper cross-domain resource definitions
(CDRSC), you can specify TSO applids from other systems as well.
Logmode
Specify the log mode entry name of line-mode bind parameters that will be used by Xpediter/Eclipse during Xpediter/TSO debugging sessions. This particular log mode entry is usually provided by IBM as a part of the default VTAM log mode table, ISTINCLM (source: SYS1.SAMPLIB member ISTINCLM). Normally, this table is already assembled and linked into SYS1.VTAMLIB and should be available.
The default log mode entry to specify for this parameter is BATCH. Within the default IBM log mode table, the name of the entry is called IBM3770, but the log mode name is BATCH as specified by the LOGMODE= parameter associated with that entry. In the event that no BATCH log mode entry is defined for your
LPAR Name
Specify the name of the LPAR that this TSO will be executing. The LPAR Name is frequently four characters but can be up to eight. The LPAR Name should relate back to the LPAR Name in HCI statement.
Step 7.Define the TP configuration APPL statements (for VTAM administrators)
Edit the TP Configuration member (default CXTP01) in the configuration load library
(COMPWARE.CX.CONFIG). Code the APPL Statements using the following format:
APPL applid
applid
The name of a VTAM applid reserved for use by Xpediter/Eclipse users during
Xpediter/TSO based debugging sessions. The APPL statement identifies VTAM applids for the secondary (SLU) side of the TSO connection for use by Xpediter/Eclipse users engaged in Xpediter/TSO debugging.
One APPL statement is required for each active debugging session. APPLs are freed after use and can be reused by the same or another Xpediter/Eclipse user when they initiate subsequent debugging sessions.
The APPLs specified can be defined to VTAM in the same domain as the TSO applid, or can be in another domain if the cross domain resources (CDRSC) are properly configured.
Up to 100 APPLs are supported. You should specify as many unique APPLs as you expect to have concurrent active debugging sessions at one time. In most cases, 30 is
8-4
Compuware Workbench Installation Guide
more than enough. If no TSO-based debugging is desired or available, or if no TSO statements (above) have been coded, then do not code any APPL statements. Code one APPL statement per line, with one applid in each statement.
Step 8.Define VTAM Parameters (for VTAM administrators)
a. Logon Mode Table Definition
In the event that the IBM-supplied log mode table ISTINCLM cannot be found, or is not available, you can define your own log mode entry to VTAM. The logon mode parameters to properly define the correct type of entry are listed below:
XBATCH MODEENT LOGMODE=BATCH,
FMPROF=X'03',
TSPROF=X'03',
PRIPROT=X'A3',
SECPROT=X'A3',
COMPROT=X'7080'
In the event that a log mode entry of BATCH is already defined by some other log mode entry in the same or a different log mode table, you can specify a new and unique name for the LOGMODE= parameter. If you do, use the new name in the logmode field of the TSO statement in the CSS TP configuration member (see step 6 above). After coding the above parameters, assemble and link your logon mode table as specified by your VTAM system documentation.
b. Xpediter/Eclipse Debugging APPL Definitions
Each APPL statement in the CSS TP configuration member must have a matching
APPL definition for VTAM. An example of the required VTAM definition is shown below. Create a new member to contain the APPL definitions in the
SYS1.VTAMLST dataset (recommended) or add them to an existing member containing other APPLs that you already have at your installation. By creating a new APPL member, you may activate it immediately after creating the member.
H01AC001 APPL AUTH=(ACQ,PASS)
H01AC002 APPL AUTH=(ACQ,PASS)
H01AC003 APPL AUTH=(ACQ,PASS)
Step 9.Install the TSO Logon Procedure
If you are using Xpediter/TSO at your location and you wish to support TSO-based debugging sessions from Xpediter/Eclipse, a specialized TSO logon procedure is required to support this environment.
A sample TSO logon procedure is supplied in the sample JCL in the CSS SLCXCNTL dataset in member ATSOECLP.
If you choose to change the name of the procedure, you need to change a corresponding setting within Xpediter/Eclipse to reflect the new name. The name must be supplied in the Procedure field of the TSO Logon Parameters section of an
Xpediter/TSO Debug Session launch configuration in Xpediter/Eclipse. To properly customize the logon procedure, edit the samples member ATSOECLP and follow these steps: a. Change the procedure name, if desired, on the PROC and EXEC statement.
b. Specify the dataset name of the Xpediter/TSO authlib (SLXTAUTH).
c. Specify the dataset name of the Xpediter/TSO loadlib (SLXTLOAD).
d. Specify, in two locations, the SYSOUT class for your installation's held output class.
e. Copy the modified logon procedure to your system proclib.
Step 10.Validate HCI JCL STEPLIB
a. Make sure the HCI JCL STEPLIB concatenation has a valid active DD statement
for the Xpediter/TSO Authorized Load Library (SLXTAUTH). See “Step 9. Submit
Xpediter/Eclipse Installation and Configuration
8-5
the HCI JCL to Start the HCI Subsystem” on page 3-23 and Figure 3-21 for more
information. b. Stop and restart HCI.
Step 11.Verification
Configure and run an Xpediter Debug Session configuration.
a. Open the Xpediter/Eclipse perspective (Compuware > Xpediter/Eclipse) b. Select Debug Configurations from the Run menu c. Create a new batch or TSO Debug Session configuration.
d. Fill in all the fields of the Debug Configuration.
e. Click the Debug button to initiate your debugging session.
f. Your program debugging session should start and position at the breakpoint at the beginning of the program.
g. Use the online Help to learn more about the Xpediter/Eclipse plug-in.
Support for Debugging CICS Programs
The process described in this section is only applicable if your site is planning to use the
Xpediter/Eclipse plug-in of Compuware Workbench to debug CICS programs with
Xpediter/CICS.
Step 1.Ensure necessary currency of Xpediter/CICS
On the Compuware Go/FrontLine home page for the Compuware Workbench product (
http://go.compuware.com
) use the Compuware Workbench Companion
Product Requirements link to verify the release and maintenance level of the
Xpediter/CICS needed to support Xpediter/Eclipse in Compuware Workbench.
Optionally, you may use the Compuware Maintenance Utility to verify your PTF
levels. See Appendix H, “Compuware Maintenance Utility”.
Step 2.Define the TP configuration CICS statements
Edit the TP Configuration member (default CXTP01) in the configuration load library
(COMPWARE.CX.CONFIG). The CICS statement identifies the CICS regions you wish to participate in debugging sessions using Xpediter/Eclipse. Specify a unique identification (Sysname), the sockets transaction ID (Tranid), the port number (Port
#), and the IP address of each CICS region you wish to participate in Xpediter/Eclipse debugging sessions. Code one CICS statement per CICS region.
The format of the CICS statement is:
CICS Sysname Tranid Port # IP address
Sysname
Specify a unique name to identify this connection to the Xpediter/Eclipse user.
This 20-character field can contain any valid characters. The name should be descriptive so the user can identify the connection point. Typically, a CICS applid-name or operating system ID plus other descriptive information is used.
The sysname is presented to the Xpediter/Eclipse user as a potential connection point.
Tranid
Specify the CICS 4-character transaction ID of the sockets transaction that was defined when Xpediter/CICS was installed and configured. The Compuware default transaction ID as shipped with Xpediter/CICS is XSOC.
Port #
8-6
Compuware Workbench Installation Guide
Specify the port number of the CICS region’s sockets transaction that was installed with Xpediter/CICS.
IP address
Specify the IP address or symbolic IP name of the CICS region.
Example:
*
* Socket
* Sysname (20 char) Tranid Port Host name or IP address
* ------------------- ------ ----- -----------------------
CICS CICSB Test Region XSOC 992 mvs1.xyzcorp.com
CICS SYSPROG Private Use XSOC 12391 mvs1.xyzcorp.com
Step 3.Verify IBM z/OS Communications Server Installation
This step describes the actions necessary to enable a user running Compuware
Workbench on their workstation to interface with the Xpediter/CICS Sockets-Based
Debugging API.
Note: Release 9.2 or higher of Xpediter/CICS is required to support CICS-based debugging sessions from Xpediter/Eclipse 4.0. Release 9.4 of Xpediter/CICS is required to support the new functionality.
Use of Xpediter/Eclipse components requires your site to install IBM’s z/OS
Communications Server product. This facility provides the TCP/IP v4 support necessary to provide socket communications between the various plug-ins of
Compuware Workbench and Compuware’s mainframe applications.
CAUTION:
Xpediter/Eclipse and its components do not contain support for TCP/IP v6 communications. Both TCP/IP v4 and v6 can coexist within the z/OS
Communications Service.
Only the steps necessary to customize your current IP CICS Sockets are covered in this step. If you do not currently have IP CICS Sockets defined in your CICS regions, you must follow the installation steps outlined in the IP CICS Sockets Guide shipped with IBM’s z/OS Communications Server.
Compuware strongly recommends the installation of the EZAC transaction and components shipped with IBM’s z/OS Communications Server. Compuware also recommends that you automatically start and shut down the IP CICS Sockets interface according to the instructions provided in the IP CICS Sockets Guide, in the section entitled “Managing IP CICS Sockets: Starting and stopping CICS automatically”.
Step 4.Define Transaction Code for Default IP CICS Sockets Listener
Xpediter/CICS requires use of the default CICS sockets listener, EZACIC02, shipped with the z/OS Communications Server.
Modify the sample RDO definition shown in Figure 8-1 as follows, then add it to any
CICS region that an Xpediter/Eclipse user may connect to:
• Although you can choose a different transaction code, Compuware suggests you use
XSKL. If you choose another transaction code, make note of it for later use in “Define
Listener to IP CICS Sockets” on page 8-9.
• The program name in the definition below, EZACIC02, may need to be modified.
– If your site has not created a customized version of EZACIC02, leave the
PROGRAM parameter unchanged.
Xpediter/Eclipse Installation and Configuration
8-7
– If your site is running a customized version of EZACIC02, determine the load module name of the customized version as follows:
• If the customized version is not named EZACIC02, leave the PROGRAM parameter unchanged.
• If the customized version is named EZACIC02, change the PROGRAM parameter to whatever name the original EZACIC02 was renamed to.
• If the original EZACIC02 was not renamed, you must recover and rename it something other than EZACIC02, then use that new name for the PROGRAM parameter.
• Transaction XSKL, or the transaction code you decide to use as the equivalent, should not be secured. If you wish to limit access to Xpediter/CICS by use of
Xpediter/Eclipse, you should instead secure transaction code XPGD as described in the next section.
• Define transaction XSKL, or equivalent, in a GROUP of your choice.
Figure 8-1. RDO Transaction Definition for XSKL
DEFINE -
TRANSACTION(XSKL) -
DESCRIPTION('Xpediter/CICS Eclipse Listener Task') -
GROUP(your group name) -
PROGRAM(EZACIC02) -
PRIORITY(255) -
TASKDATALOC(ANY) -
TASKDATAKEY(CICS)
Step 5.Define Transaction Code for Limiting Access to Xpediter/CICS Using
Xpediter/Eclipse
Xpediter/CICS requires that you define transaction XPGD, or one of your choosing, as supplied in Xpediter/CICS SMXDSAMP, member CSDXDTRN. This transaction can be used to limit access to Xpediter/CICS debugging facilities through the use of
Xpediter/Eclipse. Even if you choose to not limit access, the transaction must be defined.
– If you want to use a different transaction code:
• It must have the attributes as supplied.
• You must specify the new transaction code using the Xpediter/CICS global parameter XPGD=xxxx, where xxxx is the transaction code you elect to use.
For more information, see the Xpediter/CICS Installation Guide chapter entitled
“Global Parameters Table”.
– If you do not wish to limit access, make sure you do not secure this transaction.
– If your site wants to limit access to Xpediter/CICS debugging facilities through the use of Xpediter/Eclipse, you may do so by limiting access to transaction
XPGD. This transaction can be secured by defining user profiles in the ACICSPCT class. Any users added should have READ access. Only users who pass this security check will be allowed access to Xpediter/CICS debugging facilities using
Xpediter/Eclipse.
8-8
Compuware Workbench Installation Guide
Figure 8-2. RDO Transaction Definition for XPGD
DEFINE -
TRANSACTION(XPGD) -
DESCRIPTION(Xpediter/CICS Sockets Security) -
GROUP(XPEDR900) -
PROGRAM(XDPIMIRS) -
TASKDATALOC(ANY) -
TASKDATAKEY(CICS)
Step 6.Define Compuware Workbench Sockets Child Listener/Interface
The Compuware Workbench Sockets Child Listener/Interface program, DBUGSOCK, is a required component of the Compuware Workbench Sockets-Based Debugging
API. This program handles the TCP/IP sockets communication between the various components of the Xpediter/Eclipse package.
Add the RDO definition shown in Figure 8-3 to any CICS region that an
Xpediter/Eclipse user may connect to:
Figure 8-3. RDO Program Definition for DBUGSOCK
DEFINE
PROGRAM(DBUGSOCK)
DESCRIPTION('Xpediter/CICS Eclipse Sockets Interface')
GROUP(XPEDR900)
LANGUAGE(ASSEMBLER)
EXECKEY(CICS)
DATALOCATION(ANY)
Step 7.Define Transaction Code for Xpediter/CICS Sockets Child
Listener/Interface
The transaction code XSOC, supplied in CSDXDTRN, ensures that the appropriate connections can occur between the various components of the Xpediter/Eclipse package and will be used when specifying CICS entries in the CSS TP Configuration file.
Although you can choose a different transaction code, Compuware suggests you use
XSOC. If you choose another transaction code:
– Make note of it for later use in “Define Listener to IP CICS Sockets” on page 8-9.
– It must have the attributes as supplied.
Add the RDO transaction definition to any CICS region that an Xpediter/Eclipse user may connect to.
Xpediter/Eclipse Installation and Configuration
8-9
Figure 8-4. RDO Transaction Definition for XSOC
DEFINE
TRANSACTION(XSOC)
DESCRIPTION('Xpediter/CICS Sockets Child Listener/Interface')
GROUP(XPEDR900)
PROGRAM(DBUGSOCK)
PRIORITY(255)
TASKDATALOC(ANY)
TASKDATAKEY(CICS)
Step 8.Define Xpediter/CICS Sockets Security Exit
Xpediter/CICS provides a sockets security exit, XDPCICSE, which allows users of
Xpediter/Eclipse to be authenticated. When establishing a debugging session from
Xpediter/Eclipse, a user must provide their mainframe userid and password. This data is encrypted and passed during the connection process. Before the sockets listener attempts to pass control to the Xpediter/CICS Sockets Child Listener/Interface, additional checks are made and the userid and password are verified. The exit that does this is specified in the IP CICS Sockets Listener definition in the next section. If the userid/password is authenticated, IP CICS Sockets logs the user onto CICS and the task under which the Xpediter/Eclipse session is running is assigned that userid.
If the userid/password cannot be authenticated, the task ends and access is not allowed.
The XDPCICSE program definition is required. If you wish to ensure userid/password authentication and logon, you must specify the parameter SECEXIT=XDPCICSE in the IP CICS Sockets Listener definition in the next section. If you do not require a user to log on to CICS, leave this parameter blank. This will cause the default CICS userid to be assigned to the task under which the Xpediter/Eclipse session runs.
Figure 8-5. RDO Program Definition for Compuware Workbench Sockets Security Exit XPDCICSE
DEFINE
PROGRAM(XDPCICSE)
DESCRIPTION('Xpediter/CICS Sockets Security Module')
GROUP(XPEDR900)
LANGUAGE(ASSEMBLER)
EXECKEY(CICS)
DATALOCATION(ANY)
Step 9.Define Listener to IP CICS Sockets
This step provides the definitions required to enable the Xpediter/Eclipse components to connect and communicate properly with the Xpediter/CICS Sockets-
Based Debugging API. Many of the parameters listed below must be specified exactly as shown. Modifying them in any way can result in the unavailability of the
Xpediter/CICS Sockets-Based Debugging API and complicate problem determination.
If you are unsure of any parameter, code it as shown in the example in Figure 8-6 on page 8-10.
The definitions shown in Figure 8-6 have been formatted as though the parameters
were being entered in your original EZACICFG. Although it is possible to add them to the EZACICFG JCL stream, doing so might cause other definitions to be lost. If you have experience with regenerating your configuration dataset, use the following definitions. However, Compuware strongly recommends that you use the existing
8-10
Compuware Workbench Installation Guide
EZAC transaction, which can be secured and limited to selected users, and enter them interactively using the EZAC DEFine and ALTer parameters.
IMPORTANT:
– If you are sharing a configuration dataset among several regions, make sure you create identical definitions for all regions you want Xpediter/Eclipse users to be able to connect with. Each definition would require you to modify the APPLID and PORT parameters at a minimum. If you decided above to modify the CICS
RDO definition for the XSKL or XSOC transactions, or if you need to create unique definitions by region, you must modify the TRANID and CSTRAN
parameters as well. Do not modify any underlined parameter settings.
Note: The port number must be unique to Transaction XSKL.
– The USERID parameter can be assigned a default userid to be assigned to the task under which the Xpediter/CICS interface to Xpediter/Eclipse will run. You can choose to specify a value or not.
– The SECEXIT parameter can be used if you want to ensure that the user attempting to use Xpediter/Eclipse can be authenticated. If you want to require authentication, the program XDPCICSE must be specified. If a user cannot be authenticated, access to Xpediter/CICS debugging facilities through
Xpediter/Eclipse will be prohibited.
– WLM (Work Load Manager) parameters have been explicitly omitted. Support for this facility will be implemented in a future release.
Figure 8-6. Definitions for Enabling Listener to IP CICS Sockets
EZACICD TYPE=LISTENER, Create Listener Record (XP Eclipse) X
FORMAT=ENHANCED, Enhanced Listener X
APPLID=H01AC024, APPLID of CICS X
TRANID=XSKL, Use Clone of Standard Transaction ID X
PORT=nnnnn, CICS Port Number of listener X
AF=INET, IPv4 X
IMMED=YES, Start Listener Immediately X
BACKLOG=20, Set Backlog Value to 20 X
NUMSOCK=50, Support 50 Concurrent Connections X
ACCTIME=30, Set Timeout Value to 30 Seconds X
GIVTIME=30, Set Givesocket Timeout to 30 Seconds X
REATIME=300, Set Read Timeout to 5 minutes X
CSTRAN=XSOC, TranID Associated with DBUGSOCK X
CSSTTYP=KC, Child Server Startup Type X
CSDELAY=000000, Child Server Delay Interval X
MSGLEN=61, Length of Input Message X
PEEKDAT=NO, Peek Option X
MSGFORM=EBCDIC Output Message Format X
USERID=aaaaaaaa, Default userid to be assigned X
SECEXIT=XDPCICSE Security Exit
Step 10.Enable Xpediter/CICS Sockets-Based Debugging API
After the RDO definitions have been installed, activate the new listeners using the
EZAO transaction. This is not necessary, however, if you have stopped and started IP
CICS Sockets.
Step 11.Additional Information
A new Xpediter/CICS Global Override, XPGD=xxxx, has been added for supporting the Xpediter/Eclipse interface. This override allows the default transaction ID XPGD to be renamed to one of your choosing (xxxx). If you decide to modify this parameter, you must also ensure that its definition matches the supplied TRANSACTION definition.
Xpediter/Eclipse Installation and Configuration
8-11
Several new messages with the prefix MXDSK have been added to support the
Xpediter/Eclipse interface. The Xpediter/CICS Sockets modules XDPCICSE and
DBUGSOCK output these messages. They provide informational data, and many of them are related to the setup of the Xpediter/Eclipse interface. You are advised to review the CSMT output during and after installation or if connection or usage problems occur while attempting to use the Xpediter/Eclipse interface.
Step 12.Xpediter/CICS NEWCOPY Batch Interface
This step describes the Batch Interface to Xpediter/CICS NEWCOPY.
The Batch Interface to Xpediter/CICS NEWCOPY allows batch compile and link jobs
(or standalone linkedit jobs) to communicate with one or more CICS regions and request the NEWCOPY (PHASEIN) of the just-linked load module.
Sample JCL to merge into your existing compile and link (or standalone linkedit) procedures are in Xpediter/CICS SMXDSAMP member JCLNEWC. a. Customize the dataset name in the TPCONFIG DD statement. This dataset was
created in “Step 5. Specify Configuration Values for the Profile” on page 3-11.
b. Then modify the two related parameters LMOD and XEMBR to fit into your procedures. c. Specify the load module name of the newly-linked program in LMOD. d. Specify your TPCONFIG member name (default is
CXTP01
) in XEMBR. Depending on the requirements of your environment, XEMBR could be a static value.
Using the CSS TP Configuration File
The CSS TP configuration file (TPCONFIG) is used by both Xpediter/Eclipse and
Xpediter/CICS. Xpediter/CICS uses the CSS TP dataset for two purposes:
• To identify Xpediter/CICS Service Providers that are to share CICSPlex information.
For more information, see “Xpediter Service Provider” in the Xpediter/CICS Installation
Guide.
• To identify all of the CICS regions that should be contacted by the Xpediter/CICS
Batch Interface to NEWCOPY. For more information, see “Batch Interface to
Xpediter/CICS NEWCOPY” in the Xpediter/CICS Installation Guide.
Step 13.Stop and restart HCI
Step 14.Verification
Configure and run an Xpediter CICS Debug Session configuration.
a. Open the Xpediter/Eclipse perspective in Compuware Workbench.
b. Select Debug Configurations from the Run menu c. Create a new CICS Debug Session configuration d. Fill in all the fields of the Debug Configuration e. Click the Debug button to initiate your debugging session f. When your transaction is intercepted, your program debugging session should start and position at the breakpoint at the beginning of the program.
g. Use the online Help to learn more about the Xpediter/Eclipse plug-in.
8-12
Compuware Workbench Installation Guide
9-1
Chapter 9.
Implement the Shared Services Address Space (SSAS)
Chap 9 9
SSAS Overview
The Shared Services Address Space is needed to support Compuware Workbench functions related to DDIO processing via Host Explorer or Code Coverage/Eclipse.
Typically DDIO files are used by Xpediter to store source listings and by Abend-AID to store abend reports. If you have no need for DDIO services and are not going to use the
Code Coverage/Eclipse plug-in, you do not need to implement the SSAS.
Enable SSAS Startup and Journaling
Perform the following steps to enable SSAS usage:
Step 1. Build the SSAS journal datasets. The HCCF generates the SSAS Journal build JCL
for you. See “Step 7. Submit the JCL to create the HCI Journals and SSAS
Step 2. Modify and copy the SSAS startup procedure into a system PROCLIB. The HCCF
generates the SSAS startup procedure for you. See “Step 8. Copy the Generated
STASK and SSAS PROCS to PROCLIB” on page 3-21
Note: The SSAS procedure does not run Authorized and none of the datasets in the
STEPLIB should be APF authorized.
Step 3. Review the SSAS operation and security considerations below.
SSAS Operation
The SSAS starts automatically upon the first request from a user for services. Once the
SSAS starts, it remains active and waits for additional requests as long as the HCI remains active or until the SSAS is deliberately shut down by an authorized user. Because it is a separate address space, a small set of system commands are available to assist in its operation. These commands are used to stop the SSAS or to control its journal functions.
The SSAS supports the STOP and MODIFY system console commands.
These commands require that the name of the address space be specified. This name is
defined in the TP Configuration File (see Figure 3-10 on page 3-15). For the purposes of
this discussion, the name of the SSAS address space (the ssasname) is assumed to be
SSAS
.
To stop the address space, issue a STOP, or P, console command:
P SSAS
Once the SSAS is stopped, the address space terminates. The stop command attempts to halt all activity. If it cannot, issue a second STOP command, and the SSAS should immediately terminate. As a result, an abend S A03 may occur; this can be ignored. If a user requests a SSAS service, the SSAS starts up again automatically.
The MODIFY console command is used to control the SSAS journal. The journal provides debugging and diagnostic information if requested by Compuware Customer Support.
9-2
Compuware Workbench Installation Guide
Normally, the journaling feature is not active. In order to start journaling, use the
MODIFY commands below. There are three possible MODIFY commands that can be used to control the journal: START, STOP, and SWAP.
To start the journaling function within SSAS, issue:
F SSAS,START
To stop the journaling function within SSAS, issue:
F SSAS,STOP
To swap the recording of the journal data from one journal dataset to the next available journal dataset, issue:
F SSAS,SWAP
SSAS Security Considerations
You may wish to add the name of the start-up procedure to the STCGRP security class as appropriate for your security software. Otherwise, when the SSAS starts, it uses the default security level on your system. This does not prevent SSAS from normal operation because each user request for services runs under the security rules of that user. However, whether you add the procedure name to STCGRP or not, all the load libraries specified within the procedure must have system-wide read access.
Normally, Compuware recommends that the Shared Services load library not be APFauthorized. The SSAS is designed to run without any need for APF-authorization.
However, if your installation normally places the Shared Services load library in the system link list, the contents could become APF-authorized when executed from a link list search. In order to ensure that the SSAS runs non-authorized, you should specify the
Shared Services load library in the start-up procedure’s STEPLIB DD so that the system link list does not get searched during SSAS start-up. Further, if the Shared Services load library is APF-authorized for other reasons, the SSAS operates correctly.
10-1
Chapter 10.
Hiperstation/Eclipse Installation and Configuration
Chap 10 10
Supporting Hiperstation/Eclipse
The process described in this section is only applicable if your site is planning to use
Hiperstation/Eclipse as a workstation interface to Hiperstation. Hiperstation/Eclipse requires the installation and configuration of Hiperstation 8.0.
Previous versions of Hiperstation are not compatible with Hiperstation/Eclipse. If you have already installed a previous version of HCI in support of the Hiperstation 7.8 GUI or earlier, you will need to reinstall the HCI version 2.5 or higher plus all maintenance. The previous HCI installation will not work with Hiperstation/Eclipse.
Additional considerations include the following:
The Hiperstation/Eclipse plug-in must be installed in the Compuware Workbench or
Eclipse instance. During installation of Compuware Workbench, you must choose the
Custom install set and explicitly check the Hiperstation/Eclipse plug-in. The
Hiperstation/Eclipse plug-in can also be added after the Compuware Workbench installation by using the Help > Install New Software dialog box and pointing to the p2repo
directory on the media browser copy or the p2 site created for Eclipse installs.
When the list of components is presented, select Hiperstation/Eclipse and complete the installation.
• The SQQFLOAD library must be added to the HCI STEPLIB DD.
• The HPERPLIB statement identifying the Hiperstation Panel library (SQQFPENU)
dataset name must be added to the CSS TP configuration (Figure 10-1). Refer to
“Code the HPERPLIB Statement (Optional)” on page F-11, for additional details.
Figure 10-1. Coding the HPERPLIB statement.
************************************************************************
* DEFINE HIPERSTATION PANEL LIBRARY *
************************************************************************
*
* DSNAME
* --------------------------------------------
HPERPLIB COMPWARE.QQF800.SQQFPENU
*
10-2
Compuware Workbench Installation Guide
11-1
Chapter 11.
Code Coverage/Eclipse Installation and Configuration
Chap 11 11
Requirements for Supporting Code Coverage/Eclipse
The process described in this section is only applicable if your site is planning to use
Code Coverage/Eclipse as a workstation interface to Xpediter/Code Coverage. Code
Coverage/Eclipse requires the installation and configuration of Xpediter/Code Coverage
3.1 or higher with all current maintenance. Previous versions of Xpediter/Code Coverage are not compatible with Code Coverage/Eclipse.
Additional considerations include the following:
The Code Coverage/Eclipse plug-in must be installed in the Compuware Workbench or
Eclipse instance. During installation of Compuware Workbench, you must either choose the Programmer Productivity install set or the Custom install set and explicitly check the Code Coverage/Eclipse plug-in. The Code Coverage/Eclipse plug-in can also be added after the Compuware Workbench installation by using the Help > Install New
Software dialog box and pointing to the p2repo
directory on the media browser copy or the p2 site created for Eclipse installs. When the list of components is presented, select
Code Coverage/Eclipse and complete the installation.
• The Xpediter/Code Coverage load library (SLXVLOAD) library must be added to the
CXSSAS procedure, see Figure 3-20 on page 3-23.
Once installed, refer to the Compuware Code Coverage/Eclipse User Guide in the Help >
Help Contents for information on working with the Compuware > Code Coverage perspective.
11-2
Compuware Workbench Installation Guide
12-1
Chapter 12.
Deployment
Compuware Workbench Deployment
The Compuware Workbench installation media is designed to facilitate the installation of
Compuware Workbench by end-users and to automate the process of configuration and maintenance for them. Deployment consists of staging the media and configuration preferences to a Central File Share machine. Then, users can reference the readme.htm
file to install and configure their own copy of Compuware Workbench or to install the z/OS Product Plug-ins into Eclipse or IBM RDz.
Summary for Deployment
• Stage Preferences to a central location.
• Define the location of the deployment P2 Repository Update site.
• Modify readme.htm
and notify users of the deployment site location.
Step 1: Export Configuration Settings to Central Preferences Directory
1. From within Compuware Workbench, Eclipse, or IBM RDz, click File and select
Export... to access the Export dialog box.
2. Select Compuware and Compuware Configuration Settings to open the Export
Compuware Configuration Settings dialog box .
3. Click Select all and specify the To Directory using the Browse button to name and save the Exported preferences to a central site subdirectory,
Preferences
. (This directory is referenced by users to import the configuration settings into their instance of the Compuware Workbench client and/or z/OS Product Plug-ins in
Eclipse or IBM RDz.)
Note: For Compuware Workbench installations, this directory is provided for you in the copy of the Media Browser's files. For Eclipse users, you may need to create this directory at the root of the p2repo
site you created for installing the z/OS Product
Plug-ins (see “Installing Compuware’s z/OS Product Plug-ins into Eclipse or IBM
4. Click Finish to write the Export file.
5. Click OK on the confirmation screen.
Select File > Exit to exit Compuware Workbench.
Outline of the Deployment process for Compuware Workbench (for System Administrators)
1. Notify end-users of the location of the Media browser files and the readme.htm
file instructions for running the Media browser to perform the installation of
Compuware Workbench on their Windows workstation. The instructions for installation and configuration and getting started with Compuware Workbench are conveniently provided in the file readme.htm
at the root directory. Let users know to read this file.
Note: You should consider editing the readme.htm
file to insert the configuration values for Host Connections, the optional Compuware Workbench Server
(CWS) hostname and port, and the Compuware mainframe product plug-ins .
Editing the readme.htm
is an optional step, however, as these configurations
12-2
Compuware Workbench Installation Guide
will be established when end users import the previously exported
Compuware Configuration Settings from the
Preferences
directory of the media browser files.
Note: When deploying Compuware Workbench in a Citrix or terminal Server environment. Users do not need to install Compuware Workbench or configure Automatic Updates as the master copy of Compuware Workbench will be maintained centrally. They should still read the readme.htm
on the central site and follow instructions to establish default configurations.
For Deployment into Eclipse sites (for System Administrators)
1. Notify end-users of the location of the P2 repository you created (see “Installing
Compuware’s z/OS Product Plug-ins into Eclipse or IBM RDz” on page 4-3).
2. Have them use the information provided in the p2repo
directory file, readme.htm
, to install the z/OS Product Plug-ins into their Eclipse instance and to import the preconfigured preferences.
Note: You should edit the readme.htm
file with the specific values for your site for the
Host Connections, the optional Compuware Workbench Server (CWS) hostname and port, and Compuware mainframe product plug-ins.
Step 2. Establish Default Update Site
Skip this step if you do not plan to deploy Compuware Workbench but instead will be installing the z/OS Product Plug-ins into an Eclipse environment.
To establish an Update Site for Compuware’s z/OS Product Plug-ins
1. Use Window > Preferences> Install/Update > Available Software Sites to access the
Available Software Sites Preferences dialog box.
2. Click Add… to define a new site.
3. In the Add Site dialog box to define a new site, provide a name and specify the location on the file share of the P2 Repository. (This is folder p2repo
on the copied
media browser files' home directory.)
Important: Enter the fully qualified network name of the file share in the Location
box (For example:
\\computer.company.network\fileshare\p2repo
). End users will be importing this name and it must be valid from their machine — it must NOT contain any drive letter mappings.
Note: Copying of the Media Browser files is described in Chapter 4. “Compuware
Workbench Installation”.
4. Click OK to add the site.
5. Click Reload. The Test Connection dialog box appears to validate the connection.
6. (Recommended) Use Window > Preferences > Install/Update > Automatic Updates to access the Automatic Updates preferences dialog box. Check the box Automatically
find new updates and notify me to activate automatic update checking. Review and change any other settings as desired.
7. You should skip this step if you plan to deploy Compuware Workbench in a
Citrix or Terminal Server environment. End users will not need to set up an
Update Site and will not need to Import the default location.
Click Export to save the Software Site preference to file bookmarks.xml and place the file in the copied Media Browser files subdirectory,
Sites
. (This directory is referenced by users to import this preference into their installation of Compuware
Workbench.)
A-1
Appendix A.
Usage Restrictions
Host Explorer 5.0/CSS TP — Usage Restrictions
PDSE Dataset Support
1. 1.PDSE datasets are supported but only to the extent that they are similar to a PDS.
This means that:
– Long member names (greater than 8 bytes) are not supported.
– Any user data fields that may be present in the directory entry for a PDSE member are supported, but again only to the extent that they are supported for a
PDS. Extended directory user data beyond standard PDS limitations is not supported.
– Adding or replacing members of a program library PDSE (e.g., a LOADLIB) is not supported. This is an IBM limitation imposed by the STOW macro. (See also #2, below).
2. Moving or copying load module members from a standard PDS into a program library
PDSE is not supported. Moving or copying load module members from a program library PDSE back to a standard PDS is supported, but the resulting load module members may not be executable.
3. Results from a dataset properties display will not contain utilization results for internal PDSE pages used because this information is IBM proprietary.
4. Member names containing special characters are not supported. Host Explorer only supports member names that conform to the same characters supported by ISPF for specifying member names.
5. The maximum number of members supported for any PDS or PDSE dataset when used with Host Explorer is 32767.
6. PDSE V2 dataset capabilities (e.g., member generations and other features) are not specifically supported; Host Explorer will operate against a PDSE V2 dataset as if it were PDSE V1.
Unsupported Datasets
7. Extended format datasets are not supported.
8. Password protected datasets are not supported.
9. Non-SMS VSAM datasets cannot be deleted by Host Explorer. VSAM datasets cannot be browsed or edited by Host Explorer. However, the File-AID/Eclipse plug-in supports browsing and editing of VSAM KSDS, ESDS, and IAM datasets.
10. Source listing type DDIO files are supported if they are VSAM datasets. BDAM or SEQ type source listing DDIO files are not supported by Host Explorer. No report or transaction DDIO files of any type are supported by Host Explorer.
11. Host Explorer dataset functions operate on single volume datasets only. Multivolume datasets are not supported.
12. Host Explorer dataset functions operate on cataloged datasets only. Except for allocation of new datasets or a deliberate action to specifically catalog a dataset, any dataset that requires a volser to specify its physical location is not supported.
A-2
Compuware Workbench Installation Guide
13. Operations against RECFM=VBS datasets are not supported by Host Explorer.
However, Host Explorer can allocate a new dataset specifying RECFM=VBS.
z/OS Unix Files Limitations
14. Currently, Host Explorer only allows the browsing, editing, and saving of z/OS Unix files. No support exists to delete, rename, copy, or otherwise manipulate these files in any other manner.
15. Information contained within user assigned file tags associated with z/OS Unix files are always used to facilitate the display of the file's data by Host Explorer. This means that if the file tag specifies a code page (CCSID) number, that number will be used in the conversion of the data for proper display. Files tagged as binary will not be converted. If no file tag is assigned then the data within the file will be converted for display using the code page of the session (that is, the code page selected or defaulted when the user signed on).
Browse/Edit Limitations
16. The editing of datasets or members that contain binary data that is not part of a normal display character set is not specifically supported. Because all data from the mainframe sent to Host Explorer must be translated from EBCDIC, any attempt to edit binary-type data is risky as it cannot be guaranteed that it will contain the correct binary value if the data were saved back to the mainframe dataset after retranslation back to EBCDIC form. Therefore, editing and saving of binary data is not permitted and any data selected for edit that contains such characters are forced into a browse mode only.
Note: Note: File-AID Data Editor for File-AID/MVS does permit editing of datasets with binary data.
17. Unlike ISPF, Host Explorer supports the editing of RECFM=U datasets. In most cases, these types of datasets are load libraries and extreme caution should be exercised when attempting to edit this type of data. This situation is closely related to the prior limitation regarding the editing of binary data, above.
18. There is no support for the ISPF-like profile data that represents the characteristics of an edit session. For example, if a dataset member previously edited with ISPF using
“CAPS ON” was then subsequently edited via Host Explorer, no attempt is made to detect and force caps on. None of the ISPF edit related profile data is detected, stored, or used. This includes “CAPS ON/OFF”, “HEX ON/OFF”, “TABS”, and many others.
19. Browsing and editing of datasets or members in ISPF “packed” format is supported.
However, if a packed dataset or member is edited and then saved, the dataset or member will not be saved in packed format. RECFM=U datasets containing packed data are not supported.
JES Explorer Limitations
20. SYSOUT datasets displayed by the JES Explorer are limited to a maximum record length (LRECL) of 32000 bytes. Records wider than this can be displayed, however the data displayed will be truncated at 32000 bytes.
21. JES2 or JES3 are the only supported subsystems. One of these two subsystems must be the primary subsystem in order for JES Explorer to operate.
22. The JES Explorer provides a mechanism for Host Explorer users to cancel job output as well as jobs that are in execution. These types of requests cause a JES2 $CJ cancel command or a JES3 MODIFY command to be issued to the system in order to honor the request. Installations wishing to secure or limit what can be canceled can do so by setting the appropriate JES2.CANCEL.* or JES3.MODIFY.* profiles for the security class OPERCMDS using the security software package in use on their system. Please
Usage Restrictions
A-3
consult your installation's appropriate security software administration documentation for additional information. For RACF installations, controlling access to system operator commands via the OPERCMDS class is documented in the z/OS
Security Server RACF Security Administrator's Guide. “Administering the Use of
Operator Commands”. Please also refer to Appendix B Security Considerations within this manual for additional detailed information about JES Explorer security.
23. The JES Explorer allows Host Explorer users to view output from jobs within the system. Installations wishing to secure this access and limit any or all user access to output from other users can do so by setting the appropriate profiles for the security class JESSPOOL.
Profiles for JESSPOOL are in the format
Local-nodename.userid.jobname.jobid.dsnumber.name
Using combinations of userIDs and wildcard characters, output viewing can be limited on a userid or groupid basis as the installation chooses.
For installations that simply wish to invoke basic user level security for output where a user can only view their own output and no others, simply activate the JESSPOOL class in their security software and specify no profiles. User owning-only access is then the default action.
Please consult your installation's appropriate security software administration documentation for additional information. For RACF installations, controlling access to output via the JESSPOOL class is documented in the z/OS Security Server RACF
Security Administrator's Guide, “Controlling Access to Spool Data”. Please also refer to Appendix B Security Considerations within this manual for additional detailed information about JES Explorer security.
Miscellaneous
24. Results from a non-VSAM dataset properties display, which returns the DCB attributes and extent information about the dataset, may differ slightly from similar information provided by ISPF. The values for the amount of the extent(s) used can be different because of different calculation methods. Host Explorer uses the last TTR value in the dataset's DSCB to compute this value.
25. SMS managed datasets cannot normally be un-cataloged. Any attempt to uncatalog an SMS dataset will appear to function normally, but the dataset will remain cataloged. This is a normal function of the system and is not an error in Host
Explorer processing.
26. The statistical data for individual members is maintained by Host Explorer in a manner similar to that of ISPF. The columns for “Changed”, “Size”, “Init”, and so forth are updated in a compatible fashion. However, the “Mod” field could differ slightly from values computed by ISPF due to different calculation methods.
27. When using Problem View to assist handling compilation errors, using a temporary dataset for the SYSIN DD statement to input the source program into the Language
Processor for compilation is not recommended. Because a temporary dataset will be deleted at end of job, the source data will no longer be available for Problem View to access. This includes in-stream data via SYSIN DD * within the JCL.
28. When using Problem View and the same error message occurs repeatedly on multiple lines of the source program, only the first occurrence is reported.
29. Ideally, a user should not be logged on to different workstations using the same userid because any messages that are routed to that userid via job notification or command responses may route
A-4
Compuware Workbench Installation Guide
B-1
Appendix B.
Security Considerations
Security Considerations for Using the JES Explorer View
The JES Explorer view within the Host Explorer perspective provides a mechanism to view job output, purge job output, and cancel running jobs. All of these features can be controlled or limited by a software security product such as RACF or ACF2. In addition, for users that may not have a security package or are not implementing SYSOUT security rules through their security software, a limited set of alternative options to control what output can be viewed by Compuware Workbench users are available.
JES Explorer allows for a significant degree of freedom to view any output in the system.
This often occurs when users apply the security settings supplied by the software used to view output on an IBM-3270 type device, such as SDSF or IOF. These security settings apply only to those products and are not the same as system-wide security settings, which can be implemented using system security software products, such as RACF, ACF2, or Top Secret. Thus, a setting within SDSF or IOF to limit allowable viewing only applies to SDSF or IOF, not the system. Alternatively, if the system security software was used to impose output security, then all attempts to view output are controlled regardless of the viewing software. Compuware recommends using the available security settings of the system software security product to impose output security (Options 1 and 2, below).
The next sections discuss the available options for security limitations:
• Option 1: Controlling the ability of users to view output using a security product.
• Option 2: Controlling the ability of users to cancel jobs or output using a security product.
• Option 3: Implementing a basic form of security that limits viewing output when a security product is not installed or not configured for output control.
Option 1: Limit user’s ability to view output using a security product.
The JES Explorer view allows users to view the output from jobs within the system.
Installations wishing to secure this access and control user access to output can do so by setting the appropriate profiles for the security class JESSPOOL.
Profiles for JESSPOOL are in the format
Local-nodename.userid.jobname.jobid.dsnumber.name
Using combinations of userids and wildcard characters, output viewing can be limited on a userid
or groupid
basis as the installation chooses.
For installations that simply wish to invoke basic user-level security for output, where a user is limited to viewing only their own output, simply activate the JESSPOOL class in their security software and specify no profiles. User owning-only access is then the default action.
As provided by IBM system action, users are always allowed access to their own jobs or output, regardless of profiles under JESSPOOL that might seemingly restrict it.
Please consult your installation's appropriate security software administration documentation for additional information. For RACF installations, controlling access to
B-2
Compuware Workbench Installation Guide
output via the JESSPOOL class is documented in the z/OS Security Server RACF Security
Administrator's Guide, “Controlling Access to Spool Data”.
Option 2: Limit user’s ability to cancel jobs or purge output using a security product.
The JES Explorer viewer provides a mechanism for Compuware Workbench users to purge job output as well as cancel jobs that are in execution. These types of requests cause a
JES2 $CJ cancel command or a JES3 MODIFY command to be issued to the system in order to honor the request. Installations wishing to secure or limit what can be canceled can do so by setting the appropriate JES2.CANCEL.* or JES3.MODIFY.* profiles for the security class OPERCMDS using the security software package in use on their system.
These are the only command types that JES Explorer will issue.
Please note that setting specific OPERCMDS profiles only restricts a user's ability to issue the command itself (the user is either permitted or denied to issue the command); there is no control for which jobs can be canceled nor output be purged. In order to control a user's ability to cancel specific jobs or output, you must use OPERCMDS profiles that allow the commands above to be issued in conjunction with appropriate JESSPOOL profiles that allow ALTER access to the jobs identified by the profiles.
As provided by IBM system action, users are always allowed access to their own jobs or output, regardless of profiles under JESSPOOL that might seemingly restrict it. Further, users are always permitted to cancel their own jobs or purge their own output (if
OPERCMDS profiles allow it) even if no JESSPOOL profiles exist that would give the user
ALTER access to the resource. A JESSPOOL profile with ALTER access would be required for a user to cancel a job or purge output that he does not own.
Installations that are using output viewing software such as SDSF or IOF probably already have OPERCMDS properly set to allow JES2 $CJ or JES3 MODIFY commands to be issued by general users, so that they can purge their own output.
Installation may also choose to use conditional access profiles to control whether JES
Explorer users can issue JES2 $CJ or JES3 MODIFY commands to cancel a job or purge output. Conditional access may allow for use of some existing security rules already in place — by using the WHEN(CONSOLE(name)) conditional in your security software in conjunction with the CONSOLEPOE statement in the CSS TP Configuration File member.
The CONSOLEPOE statement allows a pseudo-console to be named that is also defined to the CONSOLE security class to be designated as a security port-of-entry. The pseudoconsole name is tested by the WHEN conditional clause (if present) in profiles for
JES2.CANCEL.* and JES3.MODIFY.* when JES2 $CJ or JES3 MODIFY commands are issued. The console name used in CONSOLEPOE and defined to the CONSOLE security class can be a new name with new conditional profiles designed solely for that console, or the name can specify an existing CONSOLE class member, such as SDSF. Installations desiring to use conditional access should refer to the CONSOLEPOE statement in the TP
configuration section, as well as the section below titled Using Conditional Access for Canceling Jobs or Purging Output via JES Explorer.
Please consult your installation's appropriate security software administration documentation for additional information. For RACF installations, controlling access to system operator commands using the OPERCMDS class is documented in IBM’s z/OS
Security Server RACF Security Administrator's Guide, in the section entitled “Administering the Use of Operator Commands”.
Option 3: Limit user's ability to view only their own output (no security product setup required).
Within the Compuware Shared Services (CSS) TP Configuration File member (this dataset is pointed to by the TPCONFIG DD statement in the HCI JCL), there is a configuration setting that can be used to allow the installer to impose a “by-userid” level of security
Security Considerations
B-3
when viewing output within the JES Explorer. This setting is the SYSOUT configuration statement.
This optional setting causes any attempts to view output by users to be denied unless they are the owning userid. This means that no user can view any other user's output, except for their own.
To enable the setting, specify the keyword BY-USERID in the SYSOUT statement. This enables the by-userid security. Otherwise, the setting is set to DEFAULT, which means that the rules of your installation's security software profiles and the JESSPOOL resource class dictate the handling of output. Compuware recommends using the JESSPOOL resource class and your security software for the best and most flexible security arrangement that meets your installation's requirements.
Note that a setting of BY-USERID does not override any rules enforced by your security software. Any rules in place that are more restrictive than by-userid security will continue to be enforced by your security software.
The default value if the SYSOUT statement is not coded is DEFAULT.
The format of the SYSOUT statement is:
SYSOUT
security-level
Where
security-level
is one of the two keywords: BY-USERID or DEFAULT. An example
of the TP Configuration File setting for SYSOUT is shown in Figure B-1.
Figure B-1. Coding the SYSOUT statement within the TP Configuration File member
*
***********************************************************************
* SECURITY SECTION *
***********************************************************************
*
* The SYSOUT statement can limit access to sysout data by userid.
* When BY-USERID is specified, the user can view only his own output
* (the user must be the owner). If DEFAULT is specified, then access
* to sysout data by all users is controlled by the JESSPOOL resource
* class and your security software settings. The default setting if
* not coded: DEFAULT.
*
*
* Sysout Access
* Control Comment
* ------------- -----------------------------------
SYSOUT DEFAULT Choices are BY-USERID or DEFAULT.
*
*
A full example of the CSS TP Configuration File member is supplied in the sample dataset
COMPWARE.MLCXNNN.SLCXCNTL(CSSTPCFG).
Using Conditional Access for Canceling Jobs or Purging Output via JES
Explorer
The TP Configuration File (TPCONFIG) provides an optional statement parameter which gives the TP the capability to name a console which is also defined to your system security software in the CONSOLE class. This console name is used to issue JES cancel and purge commands on behalf of Compuware Workbench as a security port of entry (POE).
Use of the CONSOLEPOE statement provides a mechanism for installations to use conditional security rules to control which users or groups may issue commands to the system via the WHEN(CONSOLE(console-name)) clause in security profiles.
B-4
Compuware Workbench Installation Guide
The TPCONFIG file is pointed to by the TPCONFIG DD statement in your HCI start-up
JCL.
The CONSOLEPOE statement, if coded, can be used to specify a console name under which system commands will be issued. These system commands are issued by the JES
Explorer for the purposes of purging job output or canceling active jobs. Security rules at some installations require a console name as a port of entry in order to validate the authority of the command. At present, Compuware Workbench only issues $CJ commands (JES2) or *MODIFY J=,C commands (JES3).
The console name specified by the CONSOLEPOE statement may be any name and the console name chosen must be defined to the system security software as a console in the
CONSOLE class. For RACF users, example statements used to define the console are shown below. The console name may also be a console already defined to the CONSOLE class, such as SDSF.
The console name chosen should not be the same name an existing hardware console.
There is no physical relationship between the JES Explorer console port of entry name and a real MCS console.
After specifying a CONSOLEPOE statement in your TPCONFIG member with an appropriate console name, restart the HCI. The next time a JES Explorer user wishes to cancel a job or purge output, the resulting command will be issued under the authority of the named console as a security port of entry.
This means that security rules in place that specify conditional access, for example the commonly used WHEN(CONSOLE(SDSF)) syntax, can also be specified with conditional access using the named console from the CONSOLEPOE statement, for example,
WHEN(CONSOLE(CXTP01))
Specifying the CONSOLEPOE SDSF statement in the TPCONFIG member would allow
Compuware Workbench to issue commands on behalf of the user with SDSF as the security port of entry, thereby invoking existing SDSF rules for validating the authority to issue the commands. This means that a duplicative set of rules similar to those already in place for SDSF need not be created for a console of another name (such as CXTP01 shown above).
Defining a Console to RACF to use Conditional Access
Defining an SDSF console to RACF is documented in z/OS SDSF Operation and
Customization (SA22-7670), Chapter 6, subsection "Using Conditional Access".
Similarly, to define a console to RACF for the purposes of using a console name such as the CXTP01 example above, your RACF administrator would issue the example commands below. These commands illustrate how to define a console named CXTP01 to
RACF and how to set a rule permitting a user to issue JES2 Cancel commands via the
CXTP01 port of entry.
First, activate the CONSOLE class and define the console as a member of the class:
SETROPTS CLASSACT(CONSOLE)
RDEFINE CONSOLE CXTP01 UACC(READ)
SETROPTS RACLIST(CONSOLE) REFRESH
Then, to give conditional access to permit users or groups to issue JES2 Cancel commands only when using the JES Explorer:
RDEFINE OPERCMDS JES2.CANCEL.* UACC(NONE)
PERMIT JES2.CANCEL.* CLASS(OPERCMDS) ID(userid or groupid)
ACCESS(CONTROL) WHEN(CONSOLE(CXTP01))
SETROPTS RACLIST(OPERCMDS) REFRESH
Security Considerations
B-5
Please note that the use of the CONSOLEPOE statement in TPCONFIG to establish a security port of entry for conditional access to the JES2.CANCEL.* or JES3.MODIFY.* security profiles only allows a user to issue the necessary command into the system.
Actual execution of the command and the authority to do so against the affected job or job output is still enforced by JES2 or JES3 and is subject to the security profiles of the
JESSPOOL class.
Controlling User Ability to View SYSLOG from JES Explorer
Options are available for controlling access to the system log dataset (SYSLOG) from JES
Explorer. The SYSLOG statement in the TP Configuration File member is used to control this capability for JES Explorer. The format and options of the SYSLOG statement are
detailed in Appendix F, “CSS TP Configuration Member”.
Controlling viewing access of the system log involves security profile rules, which may already exist on your system. Access to viewing may simply be a matter of using those rules for the JES Explorer to follow. However, if rules do not exist, they can be created and then specified in the TP Configuration File member.
The SYSLOG statement can be used to direct JES Explorer to follow SDSF rules or IOF rules. In these cases, the same rule (used by either SDSF or IOF) is checked by JES Explorer and viewing rights are permitted (or denied) accordingly.
For example, if you set the SYSLOG statement to use SDSF rules, and SDSF allows User A to view the system log dataset, then User A will also be able to view the system log dataset through JES Explorer. And conversely, if User A does not have viewing rights in SDSF, then the user will also not have them in JES Explorer. Rules for IOF work similarly.
Whenever an SDSF user attempts to view the system log, SDSF validates the user's access rights against a profile named ISFCMD.ODSP.SYSLOG.JESx, where x is either 2 or 3
(representing either JES2 or JES3 systems) in the SDSF security class. If a user or group has
READ access to that profile, SDSF allows viewing rights. JES Explorer follows this same
SDSF rule provided you configured a rule choice of SDSF on the SYSLOG statement. More information about the SDSF profile for system log access can be found in the IBM publication SDSF Operation and Customization (SA22-7670).
Using IOF is similar to using SDSF as described previously, however the IOF profile name must be determined by reviewing your IOF installed settings and referring to the IOF TSO
Installation Guide, within the “Access Control Reference” chapter. Once determined, specify the IOF profile name on the SYSLOG statement in the configuration (along with a rule choice of IOF). Using IOF as the rule also requires specifying the associated security class name, which can be determined by inspecting IOF's A60ACF install settings member.
Both the SDSF and IOF rule choices simply determine whether or not a given user has the right to attempt to access and view the system log. If the attempt is permitted, then JES gets involved and further checks a user's access authority for the physical system log dataset residing on the spool before any system log records are returned. This means that the user or group must also be permitted access via a profile in the JESSPOOL security class. The profile name is defined by IBM to be: system-name.+MASTER+.SYSLOG.*.*
Regardless of the rule choice chosen in the SYSLOG configuration statement, the
JESSPOOL profile must allow the user or group to have access before they will be permitted to view the system log. In most cases if a user can view the system log via SDSF or IOF today, then the JESSPOOL profile for system log access is already set properly and does not need to be adjusted.
More information about protecting the system log dataset (SYSLOG) can be found in the
IBM publication z/OS Security Server RACF Security Administrators Guide (SA22-7683), within the “Providing Security for JES” chapter. Customers using security software other than RACF should consult their appropriate documentation pertaining to securing JES.
B-6
Compuware Workbench Installation Guide
Controlling User Ability to Issue System Commands
The SYSCMD statement in the TP Configuration File member is used to access and permit users to issue system commands from Compuware Workbench—including JES commands, MVS operator commands, or any command that could be issued from a z/OS
console. The format and options of the SYSCMD statement are detailed in Appendix F,
“CSS TP Configuration Member”.
The SYSCMD statement can be used to disable access entirely, such that Compuware
Workbench users would not be able to issue commands into the system. However, many sites have groups of users authorized to issue limited system commands from a console that you may wish to extend to Compuware Workbench.
If command capability is to be permitted, then several choices exist for how you may wish to verify that a given user has the proper authority to issue commands. All of them involve security profiles that may already exist on your system, and permitting commands to be issued by Compuware Workbench is simply a matter of specifying which rules you want Compuware Workbench to follow. If rules do not currently exist, they can be created and then specified in the TP Configuration File member so that Compuware
Workbench will follow them.
Many z/OS installations use a TSO-based application, such as SDSF or IOF, to permit issuance of some commands into the system. Both of these applications are capable of validating that a TSO user has permission to issue commands (or not) by checking a security profile. The SYSCMD statement can specify which type of rules Compuware
Workbench should follow (for example, SDSF, IOF, or system rules). Regardless of what rule type is configured, the rule itself will be checked by Compuware Workbench and the command may or may not be issued depending on the result of that check. For example, if you specify on the SYSCMD statement that you want Compuware Workbench to follow
SDSF rules and SDSF allows User B to issue system commands, then User B will also be able to issue commands using Compuware Workbench. If User B does not have command authority rights in SDSF then User B will also not have them in Compuware Workbench.
Rules for IOF work similarly. The system's rules refer to the operating system validation of a profile in the OPERCMDS class prior to executing the command.
Whenever an SDSF user attempts to issue a system command, SDSF validates the user's access rights against a profile named ISFOPER.SYSTEM in the SDSF security class. If a user or group has READ access to that profile, SDSF allows the command to be issued into the system. Compuware Workbench will follow this same SDSF rule if you specify a rule choice of SDSF on the SYSCMD statement in the configuration. More information about the SDSF profile for system commands can be found in the IBM publication SDSF
Operation and Customization (SA22-7670).
IOF functions the same way, however the profile name is determined by reviewing your
IOF installed settings and referring to the IOF TSO Installation Guide, within the “Access
Control Reference” chapter. Once you determine the correct profile, specify the profile name on the SYSCMD statement in the configuration along with a rule choice of IOF.
Using IOF as the rule choice also requires that the security class name being used by IOF be specified; this can be determined by inspecting IOF's A60ACF install settings member.
Both the SDSF and IOF rule choices simply determine whether or not a given user has the right to attempt to issue a command into the system. If the attempt is permitted then the operating system gets involved and checks a user's access authority for the specific command submitted. This means that the user or group must also be permitted authority to issue the command via a profile in the OPERCMDS security class. Typical profile names are defined by IBM to be: subsystem-name.command.[qualifier]
For example:
MVS.MODIFY.STC.*
JES2.DISPLAY.*
Security Considerations
B-7
Regardless of the rule choice chosen in the SYSCMD configuration statement, the
OPERCMDS profiles must allow the user or group to have access before the command will be permitted to execute. In most cases if a user can currently issue the command from
SDSF or IOF today, then the OPERCMDS profile for command issuance is already set properly and does not need to be adjusted.
Note: It is important to understand that the settings on the SYSCMD configuration statement do not affect the ability of the user to cancel jobs or job output from
JES Explorer. The SYSCMD setting only pertains to those commands that a user can physically type in the actual command text and then attempt to have the command issued. Cancel commands issued by JES Explorer are generated internally depending on specific action by the user; the user is not allowed to type the command text or job number for this purpose. Control of JES Explorer
cancel commands is controlled by the options described in “Security
Considerations for Using the JES Explorer View” on page B-1 and “Using
Conditional Access for Canceling Jobs or Purging Output via JES Explorer” on page B-3.
More information about protecting system operator commands can be found in the IBM publication z/OS Security Server RACF Security Administrators Guide (SA22-7683), within the
“Protecting General Resources” chapter, in subsection “Administering the Use of
Operator Commands”. Customers using security software other than RACF should consult their appropriate documentation pertaining to securing JES.
B-8
Compuware Workbench Installation Guide
CXSS0000 Started-task Procedure Security
Considerations
When using the CXSS0000 started-task JCL procedure (used by File-AID/Eclipse, Strobe, and CA-Endevor support for Compuware Workbench), the system's security software must be set to allow for the jobname of the CXSS0000 procedure to increment sequentially for each invocation of a new started-task.
Each time a Compuware Workbench user initiates a new File-AID session or a CA-
Endevor session, a started-task will begin execution. It will be assigned a jobname that corresponds to the task number of the user's session with HCI. For example, CXSS0001,
CXSS0002, CXSS0003,…,CXSSnnnn.
Some installations use physical jobnames in their system security settings to place into effect restrictions or authorizations based on these jobnames. As a result, the system security settings must allow for the jobnames of the CXSS0000 started-tasks to range from CXSS0000 - CXSS9999. If your security requirements enforce the use of jobname restrictions, it is suggested that a wild-card arrangement be specified, such as CXSS* in the system security settings to allow for the full range of possible jobnames that could be generated.
When the procedure is started by the HCI, the procedure is assigned to the default security userid on the system (for example ++++++++ on RACF systems). The default security userid may not have authority to access the datasets specified in the procedure
JCL. Therefore, READ access to these datasets must be provided in order for the procedure to successfully begin execution. The two options available for establishing sufficient access authority are to either: or
• Make all of the datasets specified within the CXSS0000 procedure available for READ access by specifying UACC=READ for each dataset in the JCL. This includes all datasets in the STEPLIB DD concatenation as well as the TPCONFIG DD dataset. This option allows the system default userid to have READ access to the procedure's datasets so that the procedure can start up and the configuration file can be processed.
• Add the name of the start-up procedure to an STCGRP security class as appropriate for your security software and define all of the datasets specified in the procedure JCL as belonging to the STGGRP with READ access. This option causes the procedure to start up with the authority of STCGRP and therefore can read and process the procedure's datasets.
Once the procedure successfully begins execution, the initiating userid (the userid associated with the Compuware Workbench session that caused the procedure to get started) is authenticated and the procedure will execute under the security rules in place for that userid and not the rules of the default system userid or STCGRP. Providing READ access to the STEPLIB and TPCONFIG datasets (whether via UACC=READ or STCGRP) does not allow individual users more or less security than they had before.
SSAS Security Considerations
Refer to “SSAS Security Considerations” on page 9-2.
Security Considerations
B-9
Controlling User Access to the CSS TP's Compuware
Workbench Connection Port
The CSS TP is the entity and programming logic executing inside the HCI address space that services requests on behalf of the Compuware Workbench clients for access to z/OS resources. The TP authenticates user access by requiring that the Compuware Workbench client user provide a userid and password which will be validated by the system security software (RACF, ACF2, Top Secret, etc). If authentication is successful, then the user has the same access rights to z/OS resources as he would have if he had logged on to TSO on the same z/OS image.
Some installations may wish to limit access for certain users or groups to the CSS TP even though those users may have TSO access. Installations may have TSO security exits in place that restrict access to TSO or to resources accessible by TSO, and they find that the
CSS TP allows too much freedom based on userid and password authentication alone.
Installations may choose to optionally invoke application level security support within the CSS TP in order to limit which users or groups can access the HCI port(s) that invoke the CSS TP when a user attempts to connect to the port.
Application Level Security
System security software can control access to applications by the use of an application name. The application name is a one to eight character name that is determined by the installer or security administrator. The application name is added to the security database as a profile in the APPL security class. A possible suggested name for the application is the TPNAME, for example "CXTP01".
The security administrator then assigns one or more userids and/or groups to have READ access to the application name profile.
The application name is correspondingly made known to the CSS TP via the TP
Configuration File member, using the APPLICATION statement within the member. This statement allows the CSS TP to know the application name defined to the security software.
When the APPLICATION statement is specified in the TP Configuration File member, the
CSS TP will request that the system security software validate that the userid attempting to sign-on to the port has access to the application name. If the user has access to the application, use of CSS TP services is permitted and the session continues. If the user does not have access, the CSS TP connection with the client is terminated.
If multiple HCIs/ports are in use, a unique application name can be assigned to each port, thereby permitting or restricting access on a port-by-port basis as well as on a userid-by-userid basis.
If the APPLICATION statement is not specified in the configuration member, then the
CSS TP will not make a request to the security software to validate application access and only the userid/password authentication will be used to determine if the connection is permitted.
Defining Application Access to your Security Software
Please consult your installation's appropriate security software administration documentation for additional information on how to set up application security. For
RACF installations, protecting applications is documented in IBM’s z/OS Security Server
RACF Security Administrator's Guide (SA22-7683), in the chapter entitled "Protecting
General Resources" in subsection "Protecting Applications".
As an example of how to define application access to RACF, the following RACF commands are presented below to illustrate what is necessary to configure this level of
B-10
Compuware Workbench Installation Guide
access. In this example, an application name representing Compuware Workbench production users will be created for this purpose. The name chosen in this example is
WBPROD. Only users and groups defined to have access to the WBPROD profile will be able to successfully use Compuware Workbench to access the HCI port represented by this application name.
If you have not already done so, activate the APPL class:
SETROPTS CLASSACT(APPL)
Create a profile in the APPL class and give users or groups permission to access that application:
RDEFINE APPL WBPROD UACC(NONE)
PERMIT WBPROD CLASS(APPL) ID(userid or groupid) ACCESS(READ)
In the TP Configuration File member, specify the APPLICATION statement:
APPLICATION WBPROD
Then refresh the TP Configuration File or recycle the HCI to make application security take effect.
Note: Running multiple HCIs can have a different application name in the TP configuration for each port, thereby controlling user access on a port-by-port basis, if desired.
HCI Security Considerations
Top Secret Users
For users of Top Secret for system security, it requires a new facility to be placed in the
Facility Matrix Table. Use the following facility control options:
FACILITY (USER33=NAME=HCI)
FACILITY (HCI=NOABEND, ASUBM, NOAUDIT, AUTHINIT, NOINSTDATA)
FACILITY (HCI=MULTIUSER, PGM=HCI, SHRPRF, SIGN(M), NOTSOC)
FACILITY (HCI=RES, KEY=8, NOXDEF, NOLUMSG, NOSTMSG)
System Security for the HCI
For the HCI to properly function, it must be permitted access to the following, regardless of whether it is a started-task or a submitted job:
• All libraries in the STEPLIB concatenation must be Authorized
• HCI PARMLIB data set containing HCI Server Activation Facility members
The HCI must be authorized for the following via the MVS system security package:
• To generate SDUMPs. If DMPPFX=SDUMP has been specified (the SDUMP specification is recommended by Compuware)
• To output submitted jobs via an internal reader
• For operator commands with update authority:
– START
– STOP
Security Considerations
B-11
– CANCEL
– MODIFY (if OPCMD=MODIFY has been specified)
JES Explorer Security Frequently Asked Questions
How does the JES Explorer access and purge job output so that I can understand how to address security concerns?
Compuware Workbench issues requests for JES services to its mainframe-side counterparts: the CSS TP and HCI combination (hereafter referred to as the TP). When a request is received by the TP to view job output, the TP interprets the request and then asks JES to return the output content for a specific job by job number and by job owner.
The TP makes requests for JES services through a documented IBM JES interface (the
Spool Dataset Browse API). During the course of processing the service request, JES issues security authorization checks to the system security software to determine if the user is allowed to retrieve the requested output.
Note that these security authorization checks are made by JES itself and not by the TP.
These checks are made regardless of the presence of SDSF or other output viewing software.
When a Compuware Workbench user wishes to purge job output, a request is made to the
TP to perform that action. The TP interprets the request and asks JES to purge the job output by issuing the appropriate JES cancel command (for JES2) or modify with cancel command (for JES3). These commands are standard system operator style JES commands.
They are issued by the TP programmatically using the MGCRE macro programming interface as described in the IBM z/OS documentation.
Two authorization actions are in play during a purge output request. One action is to determine if the user is authorized to issue the necessary operator command to purge the output, and the second action is for JES to determine if the user is allowed to purge that specific output.
The operating system makes the authorization check determination if the user is permitted to issue the operator command or not. JES makes the authorization check to determine if the user is authorized to purge that specific output or not.
The TP does not make the authorization checks for command issuance or purge capability, because the system and JES always performs those functions. Thus it is the security profiles and classes for operator commands and JES spool data (OPERCMDS and
JESSPOOL respectively), that control whether a user can perform these functions.
Why are security restrictions in place for SDSF users unable to stop JES
Explorer users from viewing or purging output?
Compuware Workbench and its mainframe-side TP cannot use any security rules enforced by SDSF. Security rules for SDSF are SDSF-specific. Some installations might not even have the SDSF product as there are other alternative output viewing software products available.
The mainframe components of Compuware Workbench are totally dependent on the security software rules in place by the system security software product, for example
RACF, ACF2, Top Secret, etc. This is true for SYSOUT output access, cancel commands, or access to datasets or other system resources.
Many SDSF rules are so specific to SDSF that they control what jobs a user can see within the SDSF display (the user may not be aware there are other jobs within the system that he cannot see). These rules can also control how specific SDSF action characters are processed.
B-12
Compuware Workbench Installation Guide
However, for the purposes of canceling jobs or purging job output from JES Explorer, you can use conditional access rules within your security software product (if it supports it) to control which JES Explorer users can issue the necessary cancel commands. If you are also using conditional access for SDSF via the WHEN(CONSOLE(SDSF)) clause in security profiles, some of these existing rules for SDSF can be enforced for JES Explorer as well by using the CONSOLEPOE configuration statement in the TP Configuration File member and specifying SDSF as the console name on this statement. Please refer to the
CONSOLEPOE statement in the configuration section for more information about using conditional access.
Is there a way to distinguish between someone purging a job in SDSF on the mainframe, and someone purging a job using Compuware
Workbench?
In the system log (syslog), purge commands issued by SDSF can generally be identified by the issuing userid shown in the job number column (to the left of the command itself in the log in red). For example:
07:34:48.97 USER01 00000290 $CJ(481698),P
When purge commands are issued on behalf of Compuware Workbench, the system log will show the job number of the HCI in the job number column. For example:
07:40:07.65 J0524335 00000290 $CJ(0524350),P
In addition, the HCI job log reiterates the command issued, preceded by a CXTPMAI013I message. For example:
07.40.07 J0524335 CXTPMAI013I 0022 Req = C36C2800 cmd
07.40.07 J0524335 $CJ(0524350),P
Compuware Workbench does not have a console function in the mainframe sense, that is, there is no mechanism for a Compuware Workbench user to issue system operator commands directly. However, Compuware Workbench does issue a limited set of JES2 or
JES3 operator commands on the user's behalf for the purposes of canceling a job or job output when the user requests it. But the user is not allowed to type in the command text itself.
Installations that solely use SDSF security for enforcement have often left their system security rules "wide open" with regard to output security or operator command issuance.
If your goal is to just enforce the simple case of allowing your Compuware Workbench users to only view their own output and to cancel only their own jobs and job output - only - then the set up in the system security software is rather minimal. In this case, a profile JES2.CANCEL.* that is wildcarded for all userids needs to be created for access to
OPERCMDS as Step 1, and then simply activate the JESSPOOL class with no user profiles, as Step 2. In this way, all users are permitted to issue a JES2 $CJ command (only… no other operator command types are permitted), and once the command is passed to JES2 then JES2 will allow or disallow the cancel operation to proceed based on the profiles in the JESSPOOL class. Those rules, per the IBM documentation state: If the JESSPOOL class is simply activated with no profiles, then JES enforces user-owning security only.
Meaning, the user can only cancel (or view) their own output.
Is anyone using Compuware Workbench that has figured out a way to allow users to Cancel/Purge jobs without placing them directly on the access list for the corresponding JES2 profiles in the OPERCMDS Class?
It is not necessary to place specific users or groups on the access list for JES2 profiles in the OPERCMDS class although it is allowable to do so. It is much easier to provide access
Security Considerations
B-13
to everyone for the JES2 Cancel command by providing universal UPDATE access to the
JES2.CANCEL.* profile.
While at first thought this might seem to be a large security risk, it is not. Remember that allowing access to OPERCMDS simply authorizes a user to issue the JES2 Cancel command. It does not mean the command can execute.
Therefore, if OPERCMDS profiles will allow the user to issue the command, JES2 (or JES3) will then make a further authorization check against profiles in the JESSPOOL class to determine if the user is allowed to actually execute the command that was issued.
An installation is only at risk for generally opening up JES2.CANCEL or JES3.MODIFY profiles in OPERCMDS if the profiles in JESSPOOL are too loose.
Alternatively, an installation can choose to use conditional access rules to control which
JES Explorer users can cancel jobs and purge output. The CSS TP Configuration File member can specify the CONSOLEPOE statement which is used to specify a pseudoconsole name as a security port-of-entry for JES2 $CJ and JES3 MODIFY commands issued by JES Explorer. The name specified also must be defined to the CONSOLE security class in your security database. When this is done, profiles can be defined for JES2.CANCEL.* and JES3.MODIFY.* in the OPERCMDS class that also specify the
WHEN(CONSOLE(name)) clause. The system will then authenticate Compuware
Workbench issuer of the command as coming from that pseudo-console and if the rules allow access the command will be submitted to the system.
An installation could elect to use the existing JES2.CANCEL.* and JES3.MODIFY.* profiles that specify WHEN(CONSOLE(SDSF)) by specifying CONSOLEPOE SDSF in the configuration. JES Explorer users would have the same cancel/purge authority in JES
Explorer has they have in SDSF.
We currently have configurations to allow all users to cancel jobs/purge output but SDSF takes it from there to enforce who should be able to do that to which job in JES2, etc. If HCI does not go through SDSF how can HCI ensure that a user can't stop a production job or purge its output based on our current configurations?
In order to control how Compuware Workbench users running with the CSS TP and HCI can purge a job or job output, you use the same mechanisms that SDSF uses: A combination of the OPERCMDS class profiles and the JESSPOOL class profiles.
In order for an SDSF user to be able to accept an action character to purge a job for example, a profile had to be authorized within the OPERCMDS class such as
JES2.CANCEL.JOB.* Without this authorization, SDSF would reject the action character.
When a Compuware Workbench user issues a purge, the TP will issue the exact same type of purge command that SDSF would have issued:
Purge a job: $CJ(jobnum)
Purge job output: $CJ(jobnum),P
This means that whatever you currently have set up in your security software in order to enable SDSF to allow the purge configurations you want in effect are probably already set up correctly and you will not have to do anything additional with OPERCMDS.
It is also possible that you have set up no profiles in OPERCMDS. According to IBM documentation (z/OS Security Server RACF: Security Administrator's Guide) if
OPERCMDS class is active and there are no profiles, then each user is already authorized to issue commands to purge their own jobs or output. If you want users to be permitted to purge jobs they do not own, then one or more profiles must exist describing that job or group of jobs by using wildcarding in the profile name qualifier(s) appropriately and giving UPDATE access to the profile.
B-14
Compuware Workbench Installation Guide
But it is important to remember: OPERCMDS profiles only permit the acceptance of the
JES2 cancel command into the system. The actual act of purging a job or job output is performed by JES2 .
Before JES2 or JES3 will act on a cancel command, it will verify the following:
1.JES will verify that the JESSPOOL class is active.
2.If JESSPOOL is not active, no enforcement is in effect; any user can purge anything.
3.If JESSPOOL is active and there are no profiles describing the job or output to be purged, JES will execute the cancel command only if the userid issuing the command is the owner of the job or output.
4.Otherwise JES will only execute the cancel command only if the issuing userid has
ALTER access to the profile in the JESSPOOL class that describes the job or output to be purged.
Therefore, if you find that Compuware Workbench users are having too much freedom to purge jobs or output that you do not wish them to have, then use JESSPOOL profiles to restrict this access. You can allow them to look at such output (with READ or UPDATE access), but not purge it. They need ALTER access to be able to purge it. Or, choose access
NONE if you do not wish to allow them to even view such output.
If you find that Compuware Workbench users have insufficient access to jobs or output and you wish them to have such access, then use JESSPOOL profiles with appropriate wildcarding at one of more of the qualifier levels to grant access, via READ/UPDATE (to view output), or ALTER (to purge).
It is important to understand that the TP does not take any measures to enforce who can purge jobs or output. The TP simply submits the appropriate JES command to the system along with the userid of the requestor. The TP does not care or know if the user has authority to do so or not. And the TP does not need to know because the validation of whether the user can successfully issue and execute the JES command is enforced by system security software and the settings chosen by the security administrator via the
OPERCMDS and JESSPOOL security classes, not by the TP.
We would like to have the output access on the mainframe and the output access via Compuware Workbench behave the same to the user.
How can I set that up?
The JES Explorer and SDSF do not correspond one-for-one on exact functionality. While both products can view spool output and purge jobs, JES Explorer was not designed to control initiators, printer devices, and issue system operator commands as well as many other JES related functions. SDSF is capable of validating many complex rules in order to protect these extended functions.
JES Explorer only needs "protection" in these areas:
1.Validation of a user's authority to view job output.
2.Validation of a user's authority to cancel a job in execution or awaiting execution.
3.Validation of a user's authority to purge job output.
Each of these areas can be set up by using combinations of profiles for the JESSPOOL and
OPERCMDS classes within your security software. For example, a profile could be set up for JESSPOOL that denies viewing access to everyone (UACC=NONE) and then allows viewing access to specific users or groups via the security software access list for that profile. Similar profiles could be set up that allow only certain users or groups access to jobs that begin with certain jobname characters for example.
Security Considerations
B-15
A review of the SDSF rules in place at your shop should allow you to determine what protections are in place for the three areas above, which then can be used for from the proper profiles in JESSPOOL and OPERCMDS to create the same level of access in JES
Explorer. Installations using conditional access profiles specifying
WHEN(CONSOLE(SDSF)) can also make JES Explorer honor those profiles by specifying the CONSOLEPOE statement in the CSS TP Configuration File member. Please refer to the configuration documentation for more information and usage about the
CONSOLEPOE statement.
We use ACF2 at our shop and I have SAFDEF definitions in place to cause ACF2 to defer output security decisions to SDSF. How can I make
Compuware Workbench honor these rules? Right now Compuware
Workbench is able to purge anyone's output.
Your SAFDEF definitions are used to make ACF2 “ignore” certain profiles that it would otherwise validate for access rights. In your case the specified SAFDEFs to cause ACF2 to ignore any validation requests for JESSPOOL and OPERCMDS profiles. This means that
ACF2 security will not reject a request against these profiles and therefore a function that would request a validation check such as canceling job output will succeed. And this is exactly what you are experiencing: any Compuware Workbench user can delete any other user's output, because ACF2 was told to ignore the validations.
Your security administrator has chosen to “turn off” validation in ACF2 for the profiles in
OPERCMDS and JESSPOOL in order to let the validation decisions be made by SDSF.
That's fine. SDSF supports it. However, Compuware Workbench has no access to the SDSF rules. SDSF might not even be present in some shops. Therefore, Compuware
Workbench must rely on the profiles of JESSPOOL and OPERCMDS for validation.
Does the TP suppress the viewing of passwords contained in JES output?
No. When data is read from the spool via the JES APIs, the TP makes no attempt to locate passwords in the data and does not alter the data in any way except for normal codepageto-UTF-8 translation for viewing in Compuware Workbench. If JES passes a record back to the TP containing a password, then the password will still be there when displayed by
JES Explorer.
However, if your installation has security exits or JES exits in place that perform such a function before records are returned to a consumer of those records (such as SDSF or the
TP), then the suppression would still be in effect and JES Explorer would display a suppressed password area. In other words, the TP is not doing anything to suppress passwords or any other type of content present in spool data. If you have a suppression mechanism in place at the JES level or at the security software level, then it should still function. If the suppression function is happening at the SDSF view-time level, then JES
Explorer would still show the password data because SDSF is not there to perform the suppression.
Does the TP respect/use normal SDSF/JESSPOOL security rules?
As an example some products are allowed to access the spool, but they check with our security software before allowing viewing of output.
The answer has two parts; one for viewing output, one for canceling jobs or output.
Part 1, viewing output: When output is selected for viewing by JES Explorer, the TP invokes a call to an IBM documented service called Spool Data Set Browse (SDSB). This service is documented in the IBM publication z/OS JES Application Programming (SA23-
2240). This application programming interface (API) allows us to obtain output from spool datasets by jobname and job number. When using the API to request output, JES
B-16
Compuware Workbench Installation Guide
validates the requester (the signed-on user) against the profiles defined to the security software for the JESSPOOL class. This validation is performed by JES on behalf of the
IBM API services. So the answer to your question is no, the TP does not respect or use normal SDSF/JESSPOOL rules; the rules checking is performed by JES itself. But you can control how JES validates user access to output via JESSPOOL and appropriate profiles.
Please note: The TP does not use SDSF in any form to obtain data from the spool. Shops that do not have SDSF or IOF can still use JES Explorer to view output. There is no relationship between the TP and SDSF.
If the JESSPOOL profiles indicate that the Compuware Workbench user is not authorized to view the selected output, JES will fail the SDSB API request. The TP receives this failure and issues an appropriate return code to Compuware Workbench, which will then display a message for the end user that the output is not viewable due to security restrictions.
Part 2, Canceling jobs or job output: When a JES2 $CJ command (or JES3 *MODIFY command) is issued to cancel a job or a job's output, two validations are performed by system components: the first validation check is to determine if the user has authority to issue a command via the OPERCMDS class. If that is successful, then JES will validate if the user has ALTER authority to JESSPOOL via the profile matching: nodename.userid.jobname.jobid. Users with ALTER authority are allowed to delete output other than their own. Otherwise, the cancellation request is denied.
When the TP issues the command, it issues IBM's MGCRE macro to pass the command to the system. When you issue this macro, the user token of the signed-on user is passed as a parameter on the macro. The system uses this token to verify the ACEE (the system security control block that represents the user's access authority). Therefore, the issuer of the command is the signed-on user, and all of the OPERCMDS and JESSPOOL profile validation checks that are made by the system components will be against that signed-on userid.
If conditional access is used for SDSF via the WHEN(CONSOLE(SDSF)) clause in security profiles, the TP will honor the conditions per the profile when issuing the command if the CONSOLEPOE SDSF statement is specified in the CSS TP Configuration File member.
See “Code the CONSOLEPOE Statement (optional)” on page F-13
C-1
Appendix C.
Migrating from Previous Versions
This appendix provides the basic migration considerations for migrating from earlier releases or components of Compuware Workbench, File-AID/Eclipse (File-AID Data Editor and File-AID Search/Update), and Xpediter/Eclipse. Note that export of the current settings should be done before the new release is installed.
IMPORTANT:Compuware WorkbenchCompuware WorkbenchCompuware
WorkbenchCompuware Workbench
Compuware’s z/OS Product Plug-ins associated with Release 5.0 are not supported in
Eclipse releases prior to 4.2.2 (Juno) or IBM RDz releases prior to 9.0.
Migration Considerations for Compuware Workbench
5.0
The current Compuware configuration settings can be preserved for use in the new release of Compuware Workbench.
To prevent any loss of settings in the event of an update failure, it is recommend you save your current settings, configurations and projects before upgrading to a new release of
Compuware Workbench.
Save the following, if applicable:
• Compuware Settings (see Exporting Compuware Settings)
• Xpediter/Eclipse Debug Configurations (see Migration Considerations for
Xpediter/Eclipse)
• Compuware Projects (see Migrating Compuware Projects)
CAUTION:
Due to an upgrade of the underlying Eclipse release level that Compuware
Workbench 5.0 is based on, the uninstall method of upgrade is required. The built in
“Check for Updates” facility should not be used.
Exporting Compuware Settings
1. In the current release of Compuware Workbench (or Eclipse instance, installed with z/OS Product Plug-ins), select File > Export > Compuware > Compuware
Configuration Settings to export the configuration settings into a set of preferences files in a local directory of your choice.
2. Select Export All or choose specific configuration settings, click Finish.
Workspace Handling Considerations
The z/OS Product Plug-ins store preferences in an Eclipse-modeled workspace.
A Compuware Workbench workspace is created for each client userID in the
[user_home]\Compuware\Workbench
folder. Associating the client workspace location with userIDs enables installations of Compuware Workbench for Windows Terminal Server or
C-2
Compuware Workbench Installation Guide
Citrix deployments, as well as to facilitate user management with Windows operating systems. The location of
[user_home]
varies depending on the Windows operating system used.
When an uninstall is performed, the current location and contents of the workspace remain undisturbed, if you choose that option during the uninstall. The configurations and preferences established prior to the upgrade will be preserved within the workspace.
Once the workspace is accessed with Compuware Workbench 5.0, it will be converted for use with the new release and may no longer be usable by previous releases. Consequently, if it is desired to retain the same default workspace from a prior release after the upgrade to ensure usability, a copy of it should be made before the upgrade.
Note: You may use the File > Switch Workspace action to point to a different workspace (for example: copy of workspace). Also, the Window > Preferences >
Compuware > Recent Workspaces dialog box can be used to configure whether
you get prompted for Workspace on startup of Compuware Workbench.
It is highly advised that you use the default Workspace when migrating to any new release to prevent the loss of any preferences, settings,
configurations, or requests.
Although it is recommended that the configuration and preferences be exported prior to upgrading, this step is purely precautionary. Reimporting after the upgrade should prove unnecessary, provided the current workspace will be utilized.
Upgrade Compuware Workbench
CAUTION:
Any remaining exports of configuration settings should be completed now. Refer to those sections.
Instead of upgrading from your current installation, you may choose to install
Compuware Workbench 5.0 to a new location. You will need to manage your menu and shortcuts, and maintain distinct workspaces, to be able to launch different versions of
Compuware Workbench.
Note: You may not install the new Compuware Workbench client to a directory that already contains a previous version of Compuware Workbench.
Note: For Compuware Workbench 5.0, support is provided for running in 64-bit mode for Windows operating systems that support Windows running on a 64-bit machine. In this case the installation directory default for installing
Compuware Workbench will be
C:\Program Files\Compuware\Compuware
WorkbenchWorkbench
. Prior releases may have defaulted to
C:\Program Files
(x86)\Compuware\Workbench
. You must initially install Compuware Workbench
5.0 to a new directory in order to get 64-bit support.
Optionally, you can manually uninstall, then reinstall. Compuware Workbench can be uninstalled by using the Control Panel in Windows or by invoking the wizard located in the uninstall
folder where Compuware Workbench was initially installed (default
C:\Program Files (x86)\Compuware\
Compuware Workbench
Workbench or
C:\Program
Files\Compuware\Compuware WorkbenchWorkbench
). Double-click the executable file
uninstall.exe
. (See also “Uninstalling Compuware Workbench” on page D-4).
1. The Uninstall Compuware Workbench wizard appears, click Uninstall.
2. If you wish to keep the user-generated data and configuration settings, click Yes at the prompt.
3. Click Done when complete.
4. Follow the instructions in Chapter 4, “Compuware Workbench Installation”.
Migrating from Previous Versions
C-3
Older workspaces accessed by Compuware Workbench 5.0 or more current will be converted to the current version and may no longer be usable by the older installation of the Compuware Workbench.
Upgrading within an Eclipse-based Environment
Java JRE 1.7 build 10 or greater is required to run Compuware Workbench Release
5.0 plug-ins in an Eclipse-based environment. A minimum of the Eclipse Release
4.2.2 (Juno) or IBM RDz 9.0 is also required. For the currently supported Eclipse releases, please refer to the Compuware Workbench Release Notes.
Note: If you have Compuware’s z/OS Product Plug-ins installed in Eclipse or IBM RDz, you must first uninstall those plug-ins. Then install release 5.0 z/OS Product
Plug-ins as described in either Chapter 4. “Compuware Workbench Installation”.
Importing Compuware Settings
1. If you need to restore any Compuware settings in the new release, select File >
Import > Compuware > Compuware Configuration Settings to import the configuration settings.
2. Identify the location of your exported preferences.
3. Select Import All or choose specific configuration settings, click Finish.
Migration Considerations for HCI and the CSS TP
The z/OS Product Plug-ins are designed to work with your existing HCI and CSS TP configurations. However, if you wish to take advantage of facilities in CSS 9.0 and HCI
3.0, you should consider upgrading.
CSS TP parameters provided for in Release 5.0 of Compuware Workbench are described in
detail in Appendix F, “CSS TP Configuration Member”.
If you wish to use any of the CSS TP parameters, you will need to apply all available maintenance to HCI and CSS, then modify the CSS TP to code the new statements with your values. You may also generate a new CSS TP using the HCCF facility as discussed in
“Part 1: Install and Configure the Host Communication Interface (HCI)” on page 3-6.
Xpediter/Eclipse users should carefully merge the existing CSS TP parameters with the
CSS TP generated by the HCCF so as not to lose the Xpediter configurations for CICS,
TSO and APPL.
You do not need to change your HCI configuration to support Compuware Workbench
5.0. However, make sure all CSS and HCI maintenance is applied.
Note: In order to use the Code Coverage/Eclipse plug-in, you will need to add a STEPLIB
DD pointing to the Xpediter/Code Coverage load library (SLXVLOAD) to your
CXSSAS procedure, see Figure 3-20 on page 3-23.
It is recommended that you upgrade to HCI 3.0 at some point and convert to using the
HCIXML DD to define your HCI Configuration. Refer to the Host Communications Interface
(HCI) User/Reference Guide for information on converting from HCI 2.5 to HCI 3.0.
Converting to the XML parameters is not required, but simplifies the process of maintaining the HCI configuration.
Installations that already have an HCI running to support DevEnterprise, and do not wish to run a separate HCI for Compuware Workbench, may merge the HCI for
DevEnterprise with the HCI configuration generated by the HCCF (see Appendix G,
“Running a Single HCI to Support Compuware Workbench and DevEnterprise”).
C-4
Compuware Workbench Installation Guide
Migration Considerations for File-AID/Eclipse 5.0
Compuware Workbench 5.0 includes File-AID/Eclipse 5.0, which uses the CSS TP Start-up
Procedure (STASK) to access the minimum File-AID Common Components 2.1, File-
AID/MVS Release 9.4, File-AID for IMS 7.7,and File-AID for DB2 Release 6.3 on the mainframe (with all maintenance applied to the minimum release levels).
File-AID/Eclipse 5.0 includes support for Data Editor browse/edit of various file types with/without XREF definitions, and File-AID Search of MVS and z/OS UNIX files. In order to support File-AID/Eclipse Release 5.0, the following steps are needed.
1. Install of File-AID 10.1 or higher is recommended; or a minimum of File-
AID/Common Components 2.1.
2. Install a supported release of File-AID for DB2 (6.3 or higher) and apply all current maintenance.
Important Configuration Consideration:
If you do not wish to upgrade to File-AID for DB2 10.1, you may run File-AID for
DB2 6.3, but must make sure that the File-AID for DB2 Authorized load library
(EDITAUTH) appears in the STASK STEPLIB concatenation before any other File-
AID library.
See options in “Step 8. Copy the Generated STASK and SSAS PROCS to PROCLIB” on page 3-21
3. Install File-AID/MVS 9.4 or higher, plus all maintenance.
4. Apply the latest CSS 8.8 PTFs available from
http://go.compuware.com
or install CSS
9.0 or higher and include the latest PTFs as well.
5. File-AID Data Editor 5.0 provides support for Browse/Edit of IMS Databases. In order to use the support you must install File-AID for IMS 7.7 or higher with all maintenance applied.
6. Configure the STASK in the CSS TP and to set up the CSS TP Start-Up Procedure pointing to the authorized load and customization libraries for File-AID/MVS 9.4 or higher, File-AID for IMS 7.7 or higher, and File-AID for DB2 6.3 or higher, as well as
the HCI and CSS authorized libraries (updated with maintenance). Refer to Chapter
7, “File-AID Product Installations and Configurations”.
Note: Release 5.0 of the File-AID/Eclipse plug-in automatically supports any Data Editor or File-AID Search/Update requests created in previous releases of Compuware
Workbench. In the event of a problem occurring with a saved request, import that section of the Compuware settings that otherwise would have been exported prior to the migration.
You may be able to create a list of favorite requests by using the Last 15 Requests facility added in File-AID/Eclipse 4.0. Consult the Compuware File-AID/Eclipse User Guide in the online helps for details on using the last 15 requests facility to create a list of favorite requests you can quickly access.
Note: File-AID/Eclipse includes support for search and browse/edit of z/OS UNIX files.
CSS 8.8 or higher with all current PTFs applied is required to use this support.
Note: For installations that wish to migrate to File-AID 10.1 or higher, you may opt to set up a new HCI port with a different STASK PROC (example STASK name:
CXS20000) where the STEPLIB points to the new File-AID libraries. This would allow testing of File-AID/Eclipse with the new File-AID without disturbing current users. Once the new File-AID has been established, just update the main
STASK Proc (default CXSS0000) used by current users and specify the new File-
AID libraries and remove all other File-AID libraries
1
. There should be no
1. File-AID 10.1 or higher embeds the functionality of File-AID/Common Components, and thus no longer requires a separate installation of File-AID/Common Components.
Migrating from Previous Versions
C-5
perceptible differences between using File-AID/Eclipse with File-AID 10.1 or higher and that of releases prior to 10.1 (with all maintenance applied).
CAUTION:
If your site chooses to support pre-10.1 File-AID products on one HCI port, and File-
AID 10.1 or higher on a second HCI port, you will only be able to view the list of
File-AID Data Editor or File-AID Search requests saved for a data object on the port
on which you are logged in. All requests are port specific.
When accessing the File-AID/Eclipse from the Host Explorer view by selecting File-
AID Data Editor or File-AID Search from the context menu for a data object, you open a request to access that data. The request contains a pull-down list of all saved requests for that object. That list will only contain requests saved on the port you used to access the File-AID/Eclipse. So you will not be able to view saved requests
for the same object that were saved from a different port.
Therefore, it is advised that a second HCI port only be used for testing purposes so users will not lose any requests they have saved and defined on their main port when using a secondary port (and vice-versa). Note however that the Last 15
Requests facility of File-AID/Eclipse preserves all requests across all ports and does not have this limitation of only listing requests for the current port. In addition, there is a utility, Clone/Reassign Port in the Last 15 Requests context menu that will allow you to clone requests to a new port or to move them to a new port. In general, best practice is to define one HCI and one port per LPAR for users and to upgrade the supporting mainframe products as new releases and fixes become available and
confidence in the new code is verified.
In general, best practice is to define one HCI and one port per LPAR for Compuware
Workbench users and to upgrade the supporting mainframe products as new releases and fixes become available and confidence in the new code is verified.
Migration Considerations for Xpediter/Eclipse 5.0
Current Xpediter/Eclipse launch configurations will automatically be preserved for use in the new release, if a current workspace, or a copy of it, is being used. As a backup, follow these steps to ensure preservation of your Debug configurations.
1. In the current release of Compuware Workbench, Eclipse or IBM RDz instance installed with z/OS Product Plug-ins, select File > Export > Run/Debug to export any
Xpediter launch configurations to a local directory.
2. Select the desired Xpediter launch configurations, click Finish.
3. Perform the appropriate upgrade section previously in this appendix. Be sure to check the Compuware Xpediter/Eclipse plug-in.
4. In the new release of Compuware Workbench, Eclipse or IBM RDz instance, verify that the Xpediter/Eclipse launch configurations are still intact. If necessary, or a new workspace is being used, select File > Import > Run/Debug to import the launch configurations (contained within the preferences files). The Import Launch
Configurations dialog box appears.
5. Use the Browse... button to navigate to the appropriate directory location containing the preferences files. Once selected, check the folder in the left panel. In the right panel uncheck any launch configurations not desired. Click Finish.
C-6
Compuware Workbench Installation Guide
Compuware Workbench Server and Client
Compatibility
The Compuware Workbench client and Compuware Server should be at the same
release level. Users of File-AID Data Privacy require the use of the Compuware
Workbench Server. Installation of the Compuware Workbench Server is independent from that of the Compuware Workbench client and thus can lead to installed versions of one being incompatible with the installed version of the other. Mixed client and server versions could produce error messages or unexpected results.
When using the Data Privacy plug-in you will be notified whenever a discrepancy between versions is detected. The Compuware Workbench Server (CWS) must be updated to a supported version of the Compuware Workbench client.
Note: It is also important to ensure that the File-AID Rules Engine is updated in conjunction with the Compuware Workbench Server and the Compuware
Workbench client. See “Maintaining the File-AID Rules Engine (FARE)” on page
Migrating Compuware Mainframe Projects
Importing Compuware Mainframe Projects from Previous Releases
Note: Performing the steps in this section are only necessary if the Compuware
Workbench client or associated z/OS Product Plug-ins haven been newly installed or a new workspace is being used. These instructions can also be used to copy in
Compuware projects from other workspaces.
Note: Mainframe Projects are used for code development and testing with
Xpediter/Eclipse. They are not the same as a Data Privacy Project which may be used to disguise mainframe data.
1. In Compuware Workbench, Eclipse or IBM RDz instance, select File > Import. The
Import dialog box appears.
2. Select General > Existing Project into Workspace.
3. Click Next. The Import Projects panel displays.
4. Check Select root directory, then click Browse to select the previous release’s workspace. The Browse to Folder dialog box appears.
5. Highlight the Compuware Mainframe project folder to be imported. Click OK to select the project and dismiss the dialog box.
6. In the Import dialog box, check Copy projects into workspace, then click Finish.
7. In Project Explorer, right-click on the project, select Team > Share Project…
8. Select the Host to share (recommend specifying the same one it came from), click
Finish. If a host has not been defined yet, click Configure first.
9. Repeat the previous steps until all the desired Compuware Mainframe projects have been imported.
Importing Non-Compuware Projects from Previous Releases
Note: Importing non-Compuware projects from previous releases is only necessary if the Compuware Workbench client or the associated z/OS Product Plug-ins have
Migrating from Previous Versions
C-7
been newly installed or a new workspace is being used. These instructions can also be used to copy in projects from other workspaces.
1. In Compuware Workbench, Eclipse, or IBM RDz instance, select File > Import. The
Import dialog box appears.
2. Select General > Existing Project into Workspace.
3. Click Next. The Import Projects panel displays.
4. Check Select root directory, then click Browse to select the previous release’s workspace. The Browse to Folder dialog box appears.
5. Highlight the non-Compuware project folder to be imported. Click OK to select the project and dismiss the dialog box.
6. In the Import dialog box, check Copy projects into workspace, then click Finish.
7. Repeat the previous steps until all the desired projects have been imported.
Note: As an alternative, an Export and subsequent Import under Team > Team
Project Set may be performed.
C-8
Compuware Workbench Installation Guide
D-1
Appendix D.
Applying Compuware Workbench Cumulative
Maintenance
Installation procedures in the readme.htm
file describe the configuration steps that you should perform to set up automatic updates. If automatic updates are properly configured, you will be notified when there are new versions of any z/OS Product Plugins after the central site has been refreshed with new updates. Compuware Workbench cumulative maintenance is available on Compuware Go/FrontLine
(
http://go.compuware.com
) for downloading to update the current level of the z/OS
Product Plug-ins. Please follow the download instructions on the Compuware Workbench/
Fixes/Downloads page. Once the P2 Repository has been extracted, follow the instructions below.
IMPORTANT:
Before making updates available to all users, a best practice is to stage any updates
Compuware provides to a staging area and test the update process. Then back up the existing p2repo
directory before replacing it with the new maintenance.
CAUTION:
If moving from a previous release of Compuware Workbench to the latest release,
you will need to follow the instructions in Appendix C, “Migrating from Previous
For Compuware Workbench, Eclipse, and IBM RDz
When Compuware provides new updates to the z/OS Product Plug-ins, replace the target p2repo
directory you initially established with the p2repo
directory provided on the new media or via download from Compuware Go/FrontLine.
D
App D
Set Available Software Site for Compuware Workbench
If users have not already set up Automatic Updates and established an update site, as described in the readme.htm
, the following steps should be performed.
Step 1. In Compuware Workbench, select Window > Preferences. The Preferences dialog box appears. In the directory tree, select Install/Update > Available
Software Sites... The Available Software Sites panel displays.
Step 2. Select the Add... button the Add Site dialog box appears to specify a new site, pointing to the central p2repo
directory, in the folder originally provided for installation of Compuware Workbench. Click OK, the site should appear in the window. Click OK to close the dialog box.
Step 3. If any of the optional SlickEdit plug-ins for Java (integration with JDT), C/C++
(integration with CDT), or PHP (integration with PDT) were installed, repeat these steps to add a separate site pointing to the p2repoSEOpt
directory.
Applying Updates to z/OS Product Plug-ins
IMPORTANT:
D-2
Compuware Workbench Installation Guide
Updates can only be applied when the user is logged in to Windows with the same
ID they used when doing the initial installation of Compuware Workbench
(recommend
Administrator
). This is most important for Windows Vista, Windows 7,
Windows 8.1, and Windows Terminal Server (and Citrix) installations. The login user must have write access to the installed software directories.
Beginning with release 4.0, the Compuware Workbench installation allows for selective plug-in installation. Cumulative maintenance only applies to the plug-ins that are currently installed. An installation of newly desired plug-ins can be done from the
p2repo after the maintenance updates were completed. Please follow the instructions
under “Adding Optional or Additional z/OS Product Plug-ins” on page D-2.
When updates are detected, either automatically, or explicitly (Help > Check for
Updates in Compuware Workbench, Eclipse, or IBM RDz), an Available Updates dialog box appears listing any available updates.
To apply updates:
Step 1. Review the list and click Next to proceed with installing the updates. Some processing occurs to validate the updates and the Update Details dialog box appears.
Step 2. Click Next. The Review Licenses dialog box appears.
Step 3. Accept the License agreements and click Finish.
Step 4. If a Security Warning appears regarding unsigned content, click OK to continue.
Step 5. If the Selection Needed dialog box appears regarding trusted certificates, click
Select All, then click OK. When asked to restart Compuware Workbench,
Eclipse, or IBM RDz in the Software Updates dialog box, select Yes.
Note:
If errors occur during an update within an Eclipse environment, the z/OS Product
Plug-ins may need to be uninstalled and a Software Install attempted instead. If difficulties updating the z/OS Product Plug-ins persist, or if any attempted uninstall is unsuccessful, please contact Compuware Customer Support for further assistance.
Adding Optional or Additional z/OS Product Plug-ins
File-AID Data Privacy and Hiperstation/Eclipse are considered optional plug-ins.
Additional plug-ins were those not explicitly selected during the initial Compuware
Workbench installation. For example, the Data Privacy plug-in may need an explicit installation if it is not selected during the initial installation of plug-ins. These plug-ins must be initially installed before they can be updated with future cumulative maintenance.
Note:
Compuware Workbench implemented 64-bit support, which includes a 64-bit version of SlickEdit. The SlickEdit plug-in can now be installed into 64-bit versions of Eclipse and IBM RDz.
Note:
The File-AID Data Privacy plug-in is not supported on native Eclipse or IBM RDz.
To add z/OS Product Plug-ins:
1. Use Help > Install New Software… to access the Install wizard.
2. In the Work with: pull-down menu, select the site that points to the p2repo directory from which you just applied updates. A list of plug-ins appears.
3. Click the checkbox(s) for the desired plug-in(s), then click Next. The Install Details dialog box appears.
4. Click Next, Review Licenses displays.
5. Click the Accept radio button, then click Finish to initiate the installation.
Applying Compuware Workbench Cumulative Maintenance
D-3
6. After installation completes, click Restart Now.
7. If the optional SlickEdit support for Java (integration with JDT), C/C++ (integration with CDT), or PHP (integration with PDT) will be utilized, repeat these steps pointing to the separate p2RepoSEOpt
site. When the SlickEdit Optional Components category is displayed, expand and select the desired options.
Note:
The SlickEdit core plug-in must be installed prior to installing the optional
SlickEdit plug-ins. This would have been done during the initial z/OS Product plug-in install. The optional SlickEdit plug-ins should only be installed if the options are activated within the Eclipse environment. The Java feature can be installed into Compuware Workbench, if Java projects are used.
Applying Maintenance to the Compuware Workbench
Server
Maintenance to the Compuware Workbench Server is implemented by reinstalling the entire Compuware Workbench Server with a newer version.
The installer automatically detects that you have an existing installation and preserves your data, repositories, and configurations while applying updates.
Updates to the Compuware Workbench Server will be published to Compuware
Go/FrontLine (http://go.compuware.com) in the Fixes/Downloads page of
Compuware Workbench product page. Follow the instructions provided to download the maintenance.
Maintaining Compuware Workbench Server
Important: Access to the Compuware Workbench Server is controlled through
Compuware Distributed License Management certificates. Before updating the server, be sure to order and install new Data Privacy licenses for the latest release of the
Compuware Workbench Server.
Procedure:
1. After unzipping the downloaded maintenance, review the readme cwsmaint.htm
, documentation in the Windows folder. It will instruct you to execute the update.bat
file to reinstall/update the Compuware Workbench Server. The installer application will locate your currently installed version of the Compuware Workbench Server and backup all data and configurations. You will be warned to make sure that there are no active users before proceeding. Then the Compuware Workbench Server service will be stopped, uninstalled, and then reinstalled in the same directory. All data and repositories will be preserved. Your rules repository may need to be migrated
following an update (see step 3 on page D-3).
CAUTION:
Be sure to use the same login userID (
Administrator
) you originally specified.
Note:
For Linux installations of the CWS, upload the new binary and reinstall to the same location using the same install.bin script you tailored during the initial installation. You will be asked to preserve data — selecting Yes is recommended.
It is highly recommended that installation of the CWS in Linux be done under the authority of superuser.
2. After installation is complete, the CWS service is automatically started.
3. After updating, use Compuware Workbench to access the Data Privacy perspective. If the Data Privacy Explorer repository, File-AID Rules, has a red x icon or cannot
D-4
Compuware Workbench Installation Guide
otherwise be opened, it may need to be migrated to make it current. To migrate the repository, select Manage Repositories from the Data Privacy menu to select the repository and click Migrate. Some processing will occur to migrate the repository and then you should be able to open it.
Maintaining the File-AID Rules Engine (FARE)
Note:
When installing an update, you will be warned that an update is about to proceed. For z/OS UNIX, be sure no disguise jobs are executing. For File-AID/EX, be sure to stop the execution server for the FARE you are updating. When ready, select OK to proceed with the update. Check the readme FAREmaint
file provided with the update for details.
For z/OS UNIX (Mainframe Data Privacy only): When Compuware provides an updated installfare.jar
file, binary transfer the file to z/OS UNIX and replace the original installfare.jar
you uploaded from the media image. Then, re-invoke the installfare.sh
installation script and specify the same target directory and database
usage you originally chose for the FARE (See “Step 3. Install the File-AID Rules Engine
(FARE) on z/OS UNIX” on page 6-5). The new version will install and replace the current
version of the FARE.
For File-AID/EX (Distributed Data Privacy): Beginning with File-AID/EX 5.2.1, the
FARE may be updated independently from the File-AID/EX Execution Server.
When a new release of the FARE is made available on Compuware Go/FrontLine or via new media, the installed FARE(s) should be updated for all File-AID/EX Execution Servers
(local Windows installation of File-AID/EX as well as any installed remote execution servers in Windows or UNIX).
Please refer to the File-AID/EX Installation Guide for complete information on installing updates to the FARE in Windows or UNIX.
Uninstalling Compuware Workbench
Compuware Workbench can be uninstalled by using the Control Panel in Windows (for example: Start > Control Panel > Programs > Programs and Features) or by invoking the wizard located in the uninstall
folder where Compuware Workbench was initially installed (the default install location is
C:\Program Files (x86)\Compuware\Workbench or
C:\Program Files\Compuware\Workbench)
. Double-click the executable file uninstall.exe
.
Note: If you are uninstalling a Compuware Workbench release prior to 4.0, you will be prompted to keep user generated data and configuration settings located in the installation folder. If you select no
, all files and folders in the target folder will be deleted, including the target folder itself. If you say yes
, the
~\eclipse\workspace
folder and other files will be retained. It is recommended that you use the Export facility to save any user-generated data and configuration settings to a safe location and then, if you wish Compuware
Workbench to be completely uninstalled (all files removed), select no
when prompted.
For uninstalling Compuware Workbench 4.0 or higher, all user generated data and most configuration settings are kept in the Workspace which is stored within the
<User Home> area of the Windows file system. When you uninstall all files and folders in the target directory are deleted. Your workspace, however, is not deleted and can be used when installing a new version of Compuware Workbench. You might do this, for example, when migrating from an older version of Compuware Workbench, or when switching
Applying Compuware Workbench Cumulative Maintenance
D-5
from 32-bit to 64-bit operating mode. See Appendix C, “Migrating from Previous
Silent Uninstall
The following command is an example you can model to perform a silent uninstall with a complete deletion of the target folder:
"C:\Program Files\Compuware\Workbench\uninstall\uninstall.exe" -i silent
Uninstalling the Compuware Workbench Server
To remove the installation of the Compuware Workbench Server, you may in most cases use the Control Panel Programs facility. Optionally, you can manually invoke the uninstall script by executing the program uninstall.exe located in the uninstall directory of the target folder
(the default location is
C:\Program Files\Compuware\Workbench Server\uninstall
or
C:\Program Files
(x86)\Compuware\Workbench Server\uninstall
depending on your Windows operating system).
Once executed, the Configure Compuware Workstation Server dialog box appears with the Uninstall Product checkbox already selected. Clicking Next, then clicking Uninstall invokes a message box, prompting to keep user generated data and configuration settings located in the installation folder. If you select No, all files and folders in the target folder will be deleted, including the target folder itself. If you select Yes, the
Compuware/Workbench Server/eclipse/workspace
folder and contents will be retained.
Either selection, Yes or No, dismisses the message box and begins the removal (uninstall) of the Compuware Workbench Server.
D-6
Compuware Workbench Installation Guide
E-1
Appendix E.
Compuware Workbench Server Ancillary Procedures
App E E
Changing Compuware Workbench Server Port
Assignments
A utility is provided with the CWS to enable you to override the default port assignments.
There are three default bi-directional port numbers activated when the CWS is installed:
1. Server port: 3081
2. Data Privacy execution port: 4180
3. File-AID/Data Solutions interface port: 5180
When the utility is run, it reads the current port assignments and allows you to change them. In order for the changes to become effective, the CWS service must be stopped and restarted.
Also, note that you may need to change the port assignments configured with File-
AID/EX and File-AID/Data Solutions (see “Step 2. Install File-AID/EX” on page 6-4 and
“Step 4. Install File-AID/Data Solutions” on page 6-6). CWS also uses default port 4082 to
handle notification messages. This port is dynamic and is controlled by a Notifications callback port preference: Window > Preferences > Compuware > Notifications.
Executing the Server Configuration Utility
For Windows:
1. Use the Start > Programs > Compuware > Server > Server Configuration shortcut to invoke the utility.
2. Overtype any port numbers you wish to modify.
3. Click OK.
4. Stop and restart the Compuware Workbench Server service.
5. If changing the Compuware Workbench Server port (default: 3081), notify users by saving the Compuware Workbench Server preference and changing the readme.htm
(see Chapter 12, “Deployment” and also see step 13, “Configure the CWS in
Compuware Workbench” on page 6-3.)
6. If changing the Data Privacy execution port (default 4180) update the File-AID/EX
configuration (“Step 2. Install File-AID/EX” on page 6-4) and the File-AID/Data
Solutions Data Privacy configuration (see “Step 4. Install File-AID/Data Solutions” on page 6-6)
7. If changing the File-AID/Data Solutions port (default 5180) update the File-AID/Data
Solutions Data Privacy configuration (see “Step 4. Install File-AID/Data Solutions” on page 6-6).
For Linux:
1. In the directory containing the installed CWS, issue the shell command:
./runServerConfig.sh
2. Review and change any port numbers you wish to modify.
3. Stop and restart the Compuware Workbench Server service. See “Controlling the
Compuware Workbench Server in Linux” on page E-4.
E-2
Compuware Workbench Installation Guide
4. Be sure to modify theTopaz configuration, File-AID/EX configuration, and/or File-
AID/Data Privacy configurations to match your new port assignments (see steps 5, 6,
7 in “For Windows:” on page E-1).
Adding Compuware Workbench Server Database
Drivers
A utility is provided with the CWS for installing additional database drivers in the event you did not select a database type during the initial installation but now find the need to configure a database.
There are four types of database drivers that can be installed on the CWS:
1. Derby (installed by default and required for Data Privacy security database)
2. IBM DB2
3. Oracle
4. Microsoft SQL Server and Sybase
When the utility runs, a Data Privacy tab is provided for specifying additional database types. In order to apply any changes, the CWS service must be restarted. Also, note that if you are adding the IBM DB2 driver you will be requested to supply the location of the folder containing the DB2 JDBC driver file db2jcc.jar
and the appropriate corresponding license files for DB2 UDB on LUW and/or z/OS.
Executing the Server Configuration Utility
For Windows:
1. Use the Start > Programs > Compuware > Server > Server Configuration shortcut to invoke the utility.
2. Select the Data Privacy tab.
3. Check any database types you need. (For IBM DB2 provide the location of the folder containing the db2jcc.jar
JDCB driver file and the appropriate corresponding license files for DB2 UDB on LUW and/or z/OS. For Oracle, accept the license agreement.)
4. Click OK.
5. Restart the Compuware Workbench Server service.
For Linux:
1. In the directory containing the installed CWS, issue the shell command:
./runServerConfig.sh
2. Check any database types you need. (For IBM DB2 provide the location of the folder containing the db2jcc.jar
JDCB driver file and the appropriate corresponding license files for DB2 UDB on LUW and/or z/OS. For Oracle, accept the license agreement.)
3. Stop and restart the Compuware Workbench Server service. See “Controlling the
Compuware Workbench Server in Linux” on page E-4.
Adding File-AID Rules Engine Database Drivers
In the event you did not select a database type during the initial installation but now find the need to configure a database. You just need to rerun the FARE installation (as
described in “Step 3. Install the File-AID Rules Engine (FARE) on z/OS UNIX” on page
Compuware Workbench Server Ancillary Procedures
E-3
6-5), this time making sure you select the drivers you need. Note that if you are using the
IBM DB2 driver you will be prompted to supply the location of the folder containing the
DB2 JDBC driver file
db2jcc.jar
and the appropriate corresponding license files for DB2
UDB on LUW and/or z/OS.
Four types of database drivers can be installed on the FARE:
1. Derby (installed by default and required for Data Privacy security database)
2. IBM DB2
3. Oracle
4. Microsoft SQL Server and Sybase
Install the Compuware Workbench Server to Linux
Follow these steps to install the CWS to a Linux server. It is highly recommended that installation of the CWS in Linux be done under the authority of superuser.
Note:
If the user responsible for the server is not superuser, then once installed, the
Compuware Workbench Server should be shutdown, folder ownership and all permissions should be transferred to the userid/group responsible for the server, and the service should be restarted.
1. Copy the Disk1 folder of either the Linux subfolder from the downloaded extracted
Linux Compuware Workbench Server install files from Compuware Frontline/Go or the File-AID media directory cpwr\CWS\Linux
, to the Linux server or a directory that is mounted on the Linux server.
2. At the command prompt type which java to get the location of Java on the Linux server.
3. Set the JAVA_HOME environment variable ( export JAVA_HOME=<location of Java>
).
4. Add the
JAVA_HOME/bin
directory to the PATH environment variable
( export PATH=$JAVA_HOME/bin:$PATH
).
5. Navigate to the directory
Disk1/InstData/NoVM
under the directory where the contents were copied to in step 1.
6. Change the file install.bin to be executable ( chmod 777 install.bin
).
7. Before starting the installation, if you intend to do data privacy on IBM DB2, locate the path for the file db2jcc.jar.
8. Run the installation (
./install.bin
).
9. Once the install starts follow the prompts: a. Read the License Agreement and respond. Accept the agreement to continue with the installation. (If you do not accept the license the install will stop.) b. Enter a path in which to install or press Enter to accept the default directory as shown (in either case, you must have write access to the chosen path).
c. Confirm that the path entered is correct.
d. Select the databases that you intend to disguise using data privacy. (Use the numbers to the left of the database. Multiple databases can be selected by separating them with commas.) e. If IBM DB2 was selected, enter the path to the folder containing the db2jcc.jar
DB2 driver and the appropriate corresponding license files for DB2 UDB on LUW and/or z/OS.
f. If Oracle was selected, read and accept the license.
E-4
Compuware Workbench Installation Guide
g. Review the install directory and press Enter to start the actual installation of the product.
10. When done, validate that the service is running by using a web browser and going to this URL: http://[hostname]:4180/versions
where hostname is the IP address or DNS name of the Linux machine where the server was installed. The resulting web page should display a list of executing bundles.
Note: An alternative way to validate the service is running would be to launch
C:\Program Files (x86)\Compuware\Compuware WorkbenchWorkbench
or
C:\Program Files\Compuware\Compuware Workbench
and use the Test
Connection button in the Server Preference dialog box.
Controlling the Compuware Workbench Server in Linux
Navigate to the subdirectory ~/
Server/eclipse/bin
in the directory where you installed the CWS.
To stop the CWS issue the following command:
./platform.sh stop
To restart the CWS issue the following command:
./platform.sh start
To uninstall the CWS issue the command:
./platform.sh uninstall
To maintain the CWS, see “Applying Maintenance to the Compuware Workbench Server” on page D-3.
Installing the File-AID Rules Engine for File-AID/EX on
Unix/Linux
The File-AID Rules Engine is automatically installed with the Execution Server for File-
AID/EX Server Edition.
Refer to the File-AID/EX Installation Guide for details on installation, maintenance and operation of the Execution Server with the File-AID Rules Engine (FARE).
F-1
Appendix F.
CSS TP Configuration Member
Create and Manage the CSS TP Configuration Member
The CSS TP configuration member designates various types of information used by the mainframe side of Compuware Workbench software: the CSS TP. The TP uses the configuration information to identify other contact points to be made available to
Compuware Workbench users. Contact points can refer to CICS regions hosting Xpediter debugging in a CICS environment and VTAM applids for use in hosting Xpediter debugging sessions in the TSO environment. In addition, the configuration member provides the dataset name of the CSPF, a common repository for information required to support the debugging user.
An example of a configuration member is provided in the CSS sample library
(SLCXCNTL) dataset, member CSSTPCFG.
The TP Configuration dataset (TPCONFIG) and an initialized TP Configuration member
(tpname) are created for you by the HCCF. (For more details on the HCCF, refer to
“Configure a New HCI Image Using the Host Communication Configuration Facility
To make changes, just edit the tpname member of the TPCONFIG dataset as required to support your z/OS Product plug-in users.
Detailed explanations of each CSS TP configuration parameter are provided in this appendix.
Customize the CSS TP Configuration Member
The CSS TP configuration member has a simple format that defines connection points
and other information used by z/OS Product plug-in users. See Table F-1 for more
information.
Table F-1.
CSS TP Configuration Member Statements
Statement Type Purpose
Identifies the HCI using this configuration member
Identifies this HCI region as connectable for services in support of Host Explorer
Identifies CICS regions connectable for Xpediter/CICS debugging via the
Xpediter/Eclipse plug-in
Identifies the primary TCAS address space VTAM applid that is connectable for
Xpediter/TSO debugging via the Xpediter/Eclipse plug-in
Identifies VTAM applids for the secondary side of the connection to TSO
Identifies the dataset name of the Compuware Shared Profile dataset
To supply a JES3 command prefix for a JESPLEX
Specifies a high level dataset qualifier for internal datasets
To enable or disable use of certain plug-ins from Host Explorer
To indicate the name of the CSS TP started-task procedure
F-2
Compuware Workbench Installation Guide
Table F-1.
CSS TP Configuration Member Statements
Statement Type Purpose
Identifies the procedure name and address space name for the Compuware Shared
Services Address Space
Identifies the journal datasets to be used by the Compuware Shared Services Address
Space
This statement is required for Hiperstation/Eclipse. It identifies the name of the
Hiperstation mainframe panel library dataset name (SQQFPENU).
Provides a means to choose whether security violation messages will appear in the HCI job log whenever a Compuware Workbench user is denied access to a dataset resource.
Provides a means to limit the viewing of output by others.
Specify an inactivity time out value
Name of an alternate console for issuing operator commands via JES Explorer.
Security profile name used to control user access to HCI ports
Set up ID Card recognition option.
Optionally exclude datasets from use by Compuware Workbench.
Allow/disallow saved credentials on the workstation.
Provides for end-of-job notifications that are generated by the NOTIFY=userid JCL parameter to be sent to the Compuware Workbench user
Provides control over job completion message handling in a multiple LPAR environment. Reduces NOTIFY message traffic from other LPARs
Options to control the level of CSS TP messages written to the HCI log.
Optionally specify a default esoteric unit name.
Optionally specify a read timeout duration limit.
Code Statements
Each statement type is generally free-form. One or more blanks must precede the statement type and, thereafter, each parameter associated with that statement type must be separated by one or more blanks. The parameters are positional: the spacing between each parameter is free-form, but the parameters must be in the specified order as defined by each statement type.
Comments can be inserted into the configuration file by coding an asterisk (*) character in column 1 of each record.
The statements can be coded in any order, but they should be grouped together for clarity. If more than one LOCAL statement is detected, only the last one scanned will be used.
The sample configuration member contains comments that guide you to the proper parameters for each statement.
Code the LOCAL Statement
The LOCAL statement identifies the IP address and port number of the HCI that owns this configuration member. Code only one LOCAL statement. The format of the LOCAL statement is:
LOCAL Port # IP address zIIP-Y/N
CSS TP Configuration Member
F-3
Port #
Specify the port number of the TP assigned to service z/OS Product plug-in connections for this HCI image. This should be the same port number that is specified on the corresponding HCICNPCB element in the HCI configuration. If your
HCI configuration has more than one HCICNPCB element, use the port number from the HCICNPCB element that contains the same TPNAME= as this configuration member.
IP address
Specify the IP address or symbolic IP name of the operating system image where the
HCI executes. If you use an IP address it must be an IPV4 format.
zIIP-Y/N
Specify if the CSS TP is to be enabled to execute selected portions of TP activity on an
available zIIP processor. Code a Y or N value in this field as shown in Figure F-1.
Default if not coded: N
Figure F-1. LOCAL Statement Example
* Enable
* zIIP
* Port Host name or IP address of local HCI Y/N
* ----- ----------------------------------------- ------
LOCAL 16196 mvs1.xyzcorp.com Y
*
Or,
* Enable
* zIIP
* Port Host name or IP address of local HCI Y/N
* ----- ----------------------------------------- ------
LOCAL 883 10.10.37.240 N
*
Code the HCI Statement
You must code only one HCI statement in order to support Host Explorer connections to this LPAR, and it is the same HCI as that coded on the LOCAL statement.
The format of the HCI statement is:
HCI Sysname LPAR Name Port# IP address
Sysname
Specify a unique name to identify this connection. This 20-character field can contain any valid characters. The name should be descriptive so the user can identify the connection point. Typically, an LPAR name or operating system ID plus other
descriptive information is used (see Figure F-2).
LPAR Name
Specify the name of the LPAR that this HCI image will be executing. The LPAR name is frequently 4-characters, but can be up to 8.
Port #
Specify the port number of the CSS TP for that HCI image.
IP address
Specify the IP address or symbolic IP name of the operating system image where the
HCI executes. If you use an IP address it must be an IPV4 format.
F-4
Compuware Workbench Installation Guide
Figure F-2. HCI Statement Example
* LPAR
* Sysname (20 char) Name PORT Host name or IP address
* -------------------- -------- ----- -------------------------
HCI MVS1 Home system MVS1 16196 mvs1.xyzcorp.com
*
Code the CICS Statement
The CICS statement identifies other CICS regions at your installation that you wish to be able to participate in debugging sessions via Xpediter/Eclipse. Specify a unique identification (Sysname), the sockets transaction ID (Tranid), the port number (Port #), and the IP address of each CICS region you wish to participate in Xpediter/Eclipse debugging sessions. Code one CICS statement per CICS region. If no CICS debugging support is desired or available, do not code any CICS statements.
The format of the CICS statement is:
CICS Sysname Tranid Port # IP address
Sysname
Specify a unique name to identify this connection to the Xpediter/Eclipse user. This
20-character field can contain any valid characters. The name should be descriptive so the user can identify the connection point. Typically, a CICS applid-name or operating system ID plus other descriptive information is used. The Sysname is presented to the Xpediter/Eclipse user as a potential connection point as seen in
Tranid
Specify the CICS 4-character transaction ID of the sockets transaction that was defined when Xpediter/CICS was installed and configured. The Compuware default transaction ID as shipped with Xpediter/CICS is XSOC.
Port #
Specify the port number of the CICS region’s sockets transaction that was installed with Xpediter/CICS.
IP address
Specify the IP address or symbolic IP name of the CICS region.
Figure F-3. CICS Statement Example
*
* Socket
* Sysname (20 char) Tranid Port Host name or IP address
* ------------------- ------ ----- -----------------------
CICS CICSB Test Region XSOC 992 mvs1.xyzcorp.com
CICS SYSPROG Private Use XSOC 12391 mvs1.xyzcorp.com
*
*
CSS TP Configuration Member
F-5
Code the TSO Statement
The TSO statement identifies the VTAM applid for the TSO address space (TCAS) that is executing on the same operating system image as the HCI specified in the HCI statement above. Typically, only one TSO statement is coded, but if your VTAM network is set up with the proper cross-domain resource definitions (CDRSC), you can specify TSO applids from other systems as well. The TSO applid is used to support Xpediter/TSO debugging sessions via Xpediter/Eclipse.
Specify a unique identification (Sysname), the TCAS applid, the log mode table entry name to use, and the LPAR Name of the related HCI on this operating system image. If no
TSO debugging support is desired or available, do not code any TSO statements.
The format of the TSO statement is:
TSO Sysname Applid Logmode LPAR Name
Sysname
Specify a unique name to identify this connection to the Xpediter/Eclipse user. This
20-character field can contain any valid character. The name should be descriptive so the user can identify the connection point. Typically, an LPAR name or operating system ID plus other descriptive information is used. The Sysname is presented to the
Xpediter/Eclipse user as a potential connection point (see Figure F-4).
Applid
Specify the VTAM application ID (APPL) that is used for the primary TCAS address space on your system. This is the same APPL used by typical users logging on to TSO via a 3270 display.
Logmode
Specify the log mode entry name of line-mode bind parameters that will be used by
Xpediter/Eclipse during Xpediter/TSO debugging sessions. This particular log mode entry is usually provided by IBM as a part of the default VTAM log mode table,
ISTINCLM (source: SYS1.SAMPLIB member ISTINCLM). Normally, this table is already assembled and linked into SYS1.VTAMLIB and should be available.
The default log mode entry to specify for this parameter is BATCH. Within the default IBM log mode table, the name of the entry is called IBM3770, but the log mode name is BATCH as specified by the LOGMODE= parameter associated with that entry. In the event that no BATCH log mode entry is defined for your system, refer to
the section step 8 “Define VTAM Parameters (for VTAM administrators)” on page 8-4
for assistance in providing the correct log mode parameters.
LPAR Name
Specify the name of the LPAR that this TSO will be executing. The LPAR Name is frequently four characters but can be up to eight. The LPAR Name should relate back to one of the LPAR Names in the prior HCI statement.
Figure F-4. TSO Statement Example
* Related
* VTAM BATCH LPAR
* Sysname (20 char) APPLID LOGMODE Name
* -------------------- -------- --------- ---------
TSO TSO/MVS1 M01TSO BATCH HBP1
*
F-6
Compuware Workbench Installation Guide
Code the APPL Statement
The APPL statement identifies VTAM applids for the secondary (SLU) side of the TSO connection for use by Xpediter/Eclipse users engaged in Xpediter/TSO debugging. One
APPL statement is required for each active debugging session. APPLs are freed after use and can be reused by the same or another Xpediter/Eclipse user when they initiate subsequent debugging sessions.
The APPLs specified can be defined to VTAM in the same domain as the TSO applid, or can be in another domain if the cross domain resources (CDRSC) are properly configured.
See step 8 “Define VTAM Parameters (for VTAM administrators)” on page 8-4 for a
description of how the applids should be defined to VTAM.
Up to 100 APPLs are supported. You should specify as many unique APPLs as you expect to have concurrent active debugging sessions at one time. In most cases, 30 is more than enough.
If no TSO-based debugging is desired or available, or if no TSO statements (above) have been coded, then do not code any APPL statements.
Code one APPL statement per line, with one applid in each statement. The format of the
APPL statement is:
APPL applid
applid
The name of a VTAM applid reserved for use by Xpediter/Eclipse users during
Xpediter/TSO based debugging sessions.
Figure F-5. APPL Statement Example
*
* APPLID
* --------
APPL H01AC001
APPL H01AC002
APPL H01AC003
*
Code the CSPF Statement
The CSPF statement identifies the dataset name of the Compuware Shared Profile defined earlier. The contents of this dataset are used to supply other information to Host Explorer users.
Code one CSPF statement along with the appropriate dataset name previously assigned in
“Create the Compuware Shared Profile Dataset” on page 8-1. The format of the CSPF
statement is:
CSPF dsname
dsname
The 1- to 44-character valid dataset name of the Compuware Shared Profile dataset.
The name is not checked for validity until it is actually used and referenced by a Host
Explorer user session.
CSS TP Configuration Member
F-7
Figure F-6. CSPF Statement Example
* DSNAME
* --------
CSPF COMPUWARE.CX.CSPF
*
Code the JES3 Statement (Optional)
The JES3 statement is used for installations using a JESPLEX that require a command prefix to be specified in front of JES3 commands used to cancel or purge jobs and
SYSOUT datasets from the spool. The Host Explorer’s JES Explorer View function can issue these commands on behalf of a user in order to allow them control of their own output.
If your installation is not using JES3 or does not require a command prefix, do not code this statement. If you require a command prefix, code the prefix after the JES3 keyword.
The format of the JES3 statement is:
JES3 prefix
Prefix
Is a 1 to 8-character command prefix appended on the front of any JES3 command sent to the system.
Figure F-7. Coding the JES3 statement.
************************************************************************
* DEFINE JES3 COMMAND PREFIX (JES3 JESPLEX ONLY) *
* *
* If your installation is not using JES3 or does not *
* not require a command prefix, leave the JES3 line *
* commented out (leave the asterisk in column 1, below). *
************************************************************************
*
* PREFIX
* --------
*JES3 G0
*
Code the DSNHLQ Statement (Optional)
During the internal operation of the Compuware mainframe products that are used by
Compuware Workbench, sometimes cataloged datasets are created temporarily and then are deleted at the end of the operation. If your installation requires that cataloged datasets that are created new must begin with a fixed high level qualifier, you may specify the qualifier using the DSNHLQ statement. Compuware Workbench products that create temporary cataloged datasets during their internal operation will affix the specified qualifier to the beginning of the dataset name generated by the product. The qualifier only pertains to datasets created internally during product operation; the qualifier is not affixed to dataset names explicitly specified by theTopaz user.
If your installation does not require a fixed qualifier, leave the DSNHLQ statement commented out (leave the asterisk in column 1). Most installations should leave this statement commented out.
The format of the DSNHLQ statement is:
F-8
Compuware Workbench Installation Guide
DSNHLQ qualilfier
qualifier
Is the high level qualifier that should be affixed to the beginning of internally generated dataset names. The qualifier chosen must meet the rules for all dataset name qualifiers as required by the operating system.
Figure F-8. Coding the DSNHLQ statement.
***********************************************************************
* DEFINE DATASET NAME HIGH LEVEL QUALIFIER *
***********************************************************************
* *
* If your installation requires that temporary cataloged *
* datasets that are created as new must begin with a fixed *
* high level qualifier, you may specify the qualifier below.*
* Workbench products that create temporary cataloged *
* datasets during their internal operation will affix the *
* specified qualifier to the beginning of the dataset name. *
* The qualifier only pertains to datasets created *
* internally during product operation; the qualifier is *
* not affixed to user specified dataset names. *
* *
* If your installation does not require a fixed qualifier, *
* leave the DSNHLQ statement commented out (leave the *
* asterisk in column 1, below). Most installations should *
* leave this statement commented out. *
* *
*
* QUALIFIER Comment
* --------- ----------------------------------------------------
*DSNHLQ ABC Specify a high level dsname qualifier if required.
*
Code the ENABLE Statement (Optional)
The ENABLE statement is used to indicate to Host Explorer which other products or features are available for its use. By using this statement, Host Explorer users can be informed that a certain feature is not available without receiving abends or strange error messages when a use attempt fails.
Note that enabling some features might require other statements or parameters in the TP
Configuration file.
The format of the ENABLE statement is:
ENABLE product1-Y/N product2-Y/N productn-Y/N
product-Y/N
Is a Y or N value indicating whether the feature for that column is enabled for use by
Host Explorer.
CSS TP Configuration Member
F-9
Figure F-9. Coding the ENABLE statement.
***********************************************************************
* DEFINE FEATURE ENABLEMENT *
***********************************************************************
*
* Code a Y or N value for each feature you wish to make available
* to Host Services users.
*
*
* CA-
* Endevor
* --------
ENABLE Y
Code the STASK Statement (Optional)
The STASK statement is used to indicate the name of the JCL procedure in a system
PROCLIB in case the CSS TP must run as a started-task. If the ENABLE CA-ENDEVOR is chosen (see Coding the ENABLE statement, above), or you wish to implement the File-
AID Data Privacy and/or File-AID/Eclipse plug-in, or this HCI will be used to support
Strobe Web Services, you must specify STASK.
The name of the procedure should be any 4-characters of your choice or that your installation requires. The last 4-characters should be 0000. The supplied sample procedure has the name CXSS0000. When the HCI starts a TP using this procedure, the last 4-characters will be automatically replaced by the TP number. Thus, each TP that starts will have a unique jobname (for example, CXSS0001, CXSS0002, etc.)
The format of the STASK statement is:
STASK procname
procname
Is the 1 to 8-character name of a started-task procedure in a system PROCLIB for use by
CXSS0000.
CAUTION:
This is NOT the same procedure you created for the SSAS. Do not specify CXSSAS here.
Figure F-10. Coding the STASK statement.
*
***********************************************************************
* DEFINE PROCEDURE FOR STARTED TASK TP'S *
***********************************************************************
*
* PROCNAME
* --------
STASK CXSS0000
*
F-10
Compuware Workbench Installation Guide
Code the SSAS Statement (Optional)
The SSAS statement identifies the JCL procedure name and address space name to be used by the Compuware Shared Services Address Space.
If DDIO support via Host Explorer and/or File-AID Data Privacy z/OS metadata retrieval or support for Code Coverage/Eclipse is not desired, the SSAS statement need not be coded. If this statement is not coded, and a Host Explorer user attempts to issue any requests for services, the user will receive return code 1532, indicating that the SSAS is not defined.
Code one SSAS statement along with the appropriate procedure name and address space name (SSASNAME). The format of the SSAS statement is:
SSAS procname ssasname
procname
The 1- to 8-character valid JCL procedure name of the startup JCL for the Compuware
Shared Services Address Space. The procedure specified should have been installed in
a system PROCLIB earlier in the previous installation steps (see Chapter 9,
“Implement the Shared Services Address Space (SSAS)”). The name is not checked for
validity until it is actually used and referenced by a Compuware Workbench user session.
ssasname
The 1- to 8-character name of the SSAS address space. This name is used by the console operator commands such as STOP and MODIFY in order to control the address space. The name is not checked for validity until it is actually used and referenced by a Compuware Workbench user session.
Figure F-11. SSAS Statement Example
* PROCNAME SSASNAME
* -------- ---------
SSAS CXSSAS SSAS
*
Code the JOURNAL Statement (Optional)
The JOURNAL statement identifies the dataset names of the journal datasets to be used by the Compuware Shared Services Address Space (SSAS). If the SSAS is not defined (and the SSAS statement above is not coded), then the JOURNAL statement may be omitted.
The journal datasets contain debugging information to assist in problem determination if difficulties should occur in using the SSAS. As journal datasets are filled, the SSAS will switch to the next available journal dataset. If all journals are full, the SSAS will switch to the first journal specified and repeat the process. This functionality is identical to that of the HCI journaling feature.
Code one, two, or three JOURNAL statements, along with the dataset name of the journal dataset to be used. The format of the JOURNAL statement is:
JOURNAL dsname
dsname
The 1- to 44-character valid dataset name of a journal dataset created earlier. The name is not checked for validity until it is actually used and referenced by the SSAS.
CSS TP Configuration Member
F-11
Figure F-12. JOURNAL Statement Example
* DSNAME
* --------------------------------------
JOURNAL SSAS.JOURNAL1
JOURNAL SSAS.JOURNAL2
*
Code the HPERPLIB Statement (Optional)
The HPERPLIB is only needed if you are using the Hiperstation/Eclipse plug-in. It is required for the Hiperstation/Eclipse client to function. The single parameter for the
HPERPLIB statement is the fully qualified dataset name of the Hiperstation mainframe
ISPF panel library. This must be the name of the dataset into which the Hiperstation mainframe panels were installed for the release you are using with the
Hiperstation/Eclipse client. It must be from the same release as the Hiperstation load library specified in the STEPLIB of the HCI JCL.
The format of the HPERPLIB statement is:
HPERPLIB dataset-name
dataset-name
is the fully qualified dataset name of the Hiperstation panel library
Figure F-13. Coding the HPERPLIB statement.
************************************************************************
* DEFINE HIPERSTATION PANEL LIBRARY *
************************************************************************
*
* DSNAME
* --------------------------------------------
HPERPLIB COMPWARE.QQF800.SQQFPENU
*
Code the AUDIT Statement (Optional)
The AUDIT statement will provide a means to choose whether security violation messages will appear in the HCI job log whenever a Compuware Workbench user is denied access to a dataset resource. Code a
Y
to cause these messages to be displayed; code
N
if they are not to be displayed. The default action when the AUDIT statement is either not coded or not found in the configuration member is
N
.
The format of the AUDIT statement is:
AUDIT Y/N
Figure F-14. Coding the AUDIT statement
F-12
Compuware Workbench Installation Guide
*
***********************************************************************
* SECURITY SECTION *
***********************************************************************
*
* The AUDIT statement controls whether security messages will be
* written to the HCI job log when a user attempts access to dataset
* resources that are denied. The default setting if not coded: N.
*
*
* Show failed
* access attempts? Comment
* ---------------- -----------------------------------
AUDIT Y Code a Y or N value.
*
Code the SYSOUT Statement (Optional)
The SYSOUT statement provides a mechanism to allow installations to impose a “by userid” level of security by viewing output in the JES Explorer view of Compuware
Workbench.
This optional setting will cause attempts to view output by users to be denied unless they are the owning userid. This means that no user can view any other user's output except for their own.
To enable the setting, specify the keyword BY-USERID in the SYSOUT statement. This will enable the by-userid security. Otherwise, the setting is set to DEFAULT, which means that the rules of your installation's security software profiles and the JESSPOOL resource class will dictate the handling of output. Compuware recommends using the JESSPOOL resource class and your security software for the best and most flexible security arrangement that meets your installation's requirements.
Note that a setting of BY-USERID does not override any rules enforced by your security software. Any rules in place that are more restrictive than by-userid security will continue to be enforced by your security software.
The default value if the SYSOUT statement is not coded is DEFAULT.
The format of the SYSOUT statement is:
SYSOUT security-level
security-level
Is one of the two keywords: BY-USERID or DEFAULT.
CSS TP Configuration Member
F-13
Figure F-15. Coding the SYSOUT statement
*
***********************************************************************
* SECURITY SECTION *
***********************************************************************
*
* The SYSOUT statement can limit access to sysout data by userid.
* When BY-USERID is specified, the user can view only his own output
* (the user must be the owner). If DEFAULT is specified, then access
* to sysout data by all users is controlled by the JESSPOOL resource
* class and your security software settings. The default setting if
* not coded: DEFAULT.
*
*
* Sysout Access
* Control Comment
* ------------- -----------------------------------
SYSOUT DEFAULT Choices are BY-USERID or DEFAULT.
*
*
Code the INACTIVITY Statement (Optional)
The INACTIVITY statement controls whether users connected to Compuware Workbench should time out due to inactivity. When the INACTIVITY statement is specified with a non-zero value, users connected but inactive for the specified timeout value, are logged off from HCI, their TP subtask purged and its resources (including any enqueues) released.
When a Compuware Workbench user is purged due to inactivity, the user will have to reconnect and sign-on again, when they wish to resume work.
The timeout value is specified in minutes from 0 to 32767. The default value for the
INACTIVITY statement is 0, meaning no inactivity scan is performed and no users are purged due to inactivity. The INACTIVITY statement must be uncommented (remove the asterisk from column 1) and a non-zero value specified in order to activate the inactivity scan feature.
The format of the INACTIVITY statement is:
INACTIVITY value
value
is a numeral representing inactivity time out in minutes.
Code the CONSOLEPOE Statement (optional)
The CONSOLEPOE statement parameter gives the TP the capability to name a console, which is also defined to your system security software in the CONSOLE class. This console name is used to issue JES CANCEL and PURGE commands on behalf of
Compuware Workbench as a security Port of Entry (POE). Use of the CONSOLEPOE statement provides a mechanism for installations to use conditional security rules to control which users or groups may issue commands to the system using the
WHEN(CONSOLE(console-name))
clause in security profiles.
The CONSOLEPOE statement, if coded, can be used to specify a console name under which system commands will be issued. These system commands are issued by
Compuware Workbench JES Explorer for the purposes of purging job output or canceling active jobs. Security rules at some installations require a console name as a Port of Entry in order to validate the authority of the command. At present, Compuware Workbench only issues $CJ commands (JES2) or *MODIFY J=, C commands (JES3).The console name specified by the CONSOLEPOE statement may be any name and the console name chosen must be defined to the system security software as a console in the CONSOLE class. For
F-14
Compuware Workbench Installation Guide
RACF users, example statements used to define the console are shown below. The console name may also be a console already defined to the CONSOLE class, such as SDSF.
The console name chosen should not be the same name an existing hardware console.
There is no physical relationship between the JES Explorer console port of entry name and a real MCS console.
The format of the CONSOLEPOE statement is:
CONSOLEPOE name
name
is a 2- to 8-character name also defined to the CONSOLE security class. Below is an example of the CONSOLEPOE statement as it might be coded in the TP Configuration
File member.
Note: At least 1 blank character must precede the CONSOLEPOE statement.
Figure F-16. CONSOLEPOE Statement Example
*
* Console
* Name Comment
* -------- -----------------------------------
CONSOLEPOE CXTP01 Specify port of entry for security
* profiles containing WHEN(CONSOLE( ))
*
After specifying a CONSOLEPOE statement, the next time a JES Explorer user wishes to cancel a job or purge output, the resulting command will be issued under the authority of the named console as a security port of entry.
This means that security rules in place that specify conditional access, for example the commonly used WHEN(CONSOLE(SDSF)) syntax, can also be specified with conditional access using the named console from the CONSOLEPOE statement, for example
WHEN(CONSOLE(CXTP01)).
Specifying the CONSOLEPOE SDSF statement would allow Compuware Workbench to issue commands on behalf of the user with SDSF as the security port of entry, thereby invoking existing SDSF rules for validating the authority to issue the commands. This means that a duplicative set of rules similar to those already in place for SDSF need not be created for a console of another name (such as CXTP01 shown above).
Note that the use of the CONSOLEPOE statement to establish a security port of entry for conditional access to the JES2.CANCEL.* or JES3.MODIFY.* security profiles only allows a user to issue the necessary command into the system. Actual execution of the command and the authority to do so against the affected job or job output is still enforced by JES2 or JES3 and is subject to the security profiles of the JESSPOOL class.
Please refer to “Using Conditional Access for Canceling Jobs or Purging Output via JES
Explorer” on page B-3 in for more information about using and setting up conditional
profiles.
Code the APPLICATION Statement (Optional)
The APPLICATION statement identifies an application profile name also known to the system security software which can optionally be used to further restrict access to the TP port to specific users or groups.
User access to this TP port can be restricted by use of an APPL class profile if it is supported by your security software (such as RACF). To use an APPL class profile to restrict access to certain users or groups, specify an application name using the
CSS TP Configuration Member
F-15
APPLICATION statement. The name can be any name you choose to represent the port or system on which this TP is executing, for example WBPROD, WBTEST, or CXTP01.
Then add the chosen name as a profile in the APPL class to your security software database.
User access can then be controlled by assigning userids or groups to have READ access to that profile. Users or groups that do not have READ access will not be permitted to use the port and their Compuware Workbench session will be terminated.
Validation of user access to the profile occurs only after the userid and password have been authenticated. If the profile name specified is not known to the security software
(that is, not defined in the security database) then access to the TP port will be permitted if the userid and password were valid.
If the APPLICATION profile name is not specified, then access to the TP port is based on userid and password authentication only. This is the default action and is consistent with the behavior of all prior releases of Compuware Workbench. Therefore, most installations should not specify an APPLICATION profile name and allow user authentication based on userid and password only.
The format of the APPLICATION statement is:
APPLICATION name
name
is a 1- to 8-character application profile name to be assigned to this TP port represented by this TP Configuration. This same name must be made known to the security software.
Please refer to Controlling User Access to the CSS TPs Connection Port for more information about using and setting up application profiles.
Figure F-17. APPLICATION Statement Example
*
* APPL Class
* Profile Name Comment
* -------- -----------------------------------
APPLICATION WBPROD Profile name must be 1-8 characters.
*
Code the SYSCMD Statement (Optional)
(This statement is reserved for future use) The SYSCMD statement enables or disables the ability of Compuware Workbench users to issue MVS system commands. If enabled, each user is subject to security rules in place on your system. If disabled, no Compuware
Workbench user will be able to issue a MVS system command regardless of whatever privileges they may have when using TSO/ISPF applications.
Specify a Y or N value to indicate you want the MVS system command feature to be enabled (subject to security rules) or to be disabled entirely.
Some installations use SDSF or IOF to allow authorized users to enter system commands into the system. If so, you may optionally specify SDSF or IOF as the rule choice in the
SYSCMD statement as shown below. Otherwise, specify SYSTEM in the rule choice area of the SYSCMD statement.
If SDSF is specified as the rule choice, then a given user can only issue system commands if their userid has READ access to the security profile ISFOPER.SYSTEM in the SDSF security class. SDSF itself uses this class and profile to determine if the TSO user should be permitted to issue commands within SDSF. If SDSF is specified as the rule choice, then the system command feature will permit command issuance if SDSF permits it or deny command issuance if SDSF denies it.
F-16
Compuware Workbench Installation Guide
If IOF is specified as the rule choice, then a given user can only issue system commands if their userid has access to the IOF resource class and resource name specified in the
SYSCMD statement as shown below. IOF uses this class and profile to determine if the
TSO user should be permitted to issue commands via IOF. If IOF is specified as the rule choice, then the system command feature will permit command issuance if IOF permits it or deny command issuance if IOF denies it. IOF has special class and resource name requirements; see below for more information.
If SYSTEM is specified, then a given user can only issue system commands if their userid has valid security profiles in the OPERCMDS class. The OPERCMDS class contains a large number of possible profiles, arranged by command type and often by specific operands on the command. Consult your security software documentation for specifics about specifying command profiles for OPERCMDS.
Note that regardless of the rule choice coded on the SYSCMD statement, if the user is allowed to issue commands under that rule then the operating system will always enforce validation of the command issued based on the user's profiles in the OPERCMDS class.
For example if SDSF is specified as the rule choice, the TP will validate the user's authority to issue a command into the system based on SDSF rule for that user—but if the command is allowed to be issued then the operating system will still validate the command type and its operands based on the user's profiles in the OPERCMDS class.
The default setting if SYSCMD is not coded:
SYSCMD N
The default rule choice if SYSCMD Y is coded, but no Rule-choice is coded:
SYSTEM
The format of the SYSCMD statement is:
SYSCMD Y/N Rule-choice IOF-class IOF-resource-profile
Y/N
is a single character of Y or N to indicate whether MVS system command capability should be enabled or disabled for all Compuware Workbench users
Rule-choice
is one of SYSTEM, SDSF, or IOF to specify whether system rules, SDSF rules, or IOF rules are to be followed for verifying if a user has command authority
IOF-class
is the IOF security class name. The IOF-class must be specified if the Rule-choice is specified as IOF
IOF-resource-profile
is the IOF resource name to be validated to determine if a user has IOF command authority. The IOF-resource-profile must be specified if the rule choice is specified as IOF.
Figure F-18 contains examples of the SYSCMD statements as it might be coded in the TP
Configuration File member.
Note:
At least one blank character must precede the active SYSCMD statement. As a practice, code only one SYSCMD statement. Any others should be commentedout (by placing an asterisk (*) in column 1) or removed entirely. If, however, multiple SYSCMD statements are coded, the last statement scanned is the statement in effect.
CSS TP Configuration Member
F-17
Figure F-18. SYSCMD Statement Example
If rule
is IOF:
Enable? Rule Specify If rule is IOF:
(Y/N) Choice Class Specify resource name (44 char max)
----- ------ -------- ---------------------------------------
SYSCMD N
*SYSCMD Y SYSTEM
*SYSCMD Y SDSF
*SYSCMD Y IOF DATASET IOFACF.STA.U.COMM.CMDC.*
In order to determine the proper values to specify for IOF-class and IOF-resource-profile, review your IOF installed settings and IOF documentation. The IOF-class is designated in the A60ACF member of the IOF access control settings. According to IOF documentation the default class setting is DATASET. The IOF-resource-profile to specify is determined from the construction of a global resource name. These names are documented in the IOF TSO
Installation Guide, in the “Access Control Reference” chapter, in the section pertaining to global resource names.
Note that job cancel and job output purge commands issued by JES Explorer are not subject to the controls specified by SYSCMD. SYSCMD only controls commands that a user could potentially enter and issue through the Host Explorer z/OS console interface.
Whereas, JES Explorer generates a proper JES cancel or purge command based on the selected job in the JES Explorer view. The control mechanisms for issuing commands through JES Explorer are specified in the CONSOLEPOE and SYSOUT statements; and also the rules contained in profiles that are part of the JESSPOOL and OPERCMDS security classes.
Please refer to “Controlling User Access to the CSS TP's Compuware Workbench
Connection Port” on page B-9 for more information about using and setting up rules to
control this feature.
Code the SYSLOG Statement (Optional)
The SYSLOG statement enables or disables the ability of Compuware Workbench users to view the system log (SYSLOG) using JES Explorer. If enabled, each Compuware
Workbench user is subject to security rules in place on your system. If disabled, users will not be able to view the system log, regardless of privileges, when using TSO-based output viewing applications (such as SDSF or IOF).
Specify a Y or N value to indicate you want the system log viewing to be enabled (subject to security rules) or to be disabled entirely.
Most installations use SDSF or IOF for output viewing. These viewer applications can also enforce rules to allow or disallow users from viewing the system log. If you wish JES
Explorer to follow the rules imposed by SDSF or IOF, specify SDSF or IOF as the Rule-
choice in the SYSLOG statement. Otherwise, specify SYSTEM.
If SDSF is specified as the Rule-choice, then a given userid can only view the system log— provided the userid has READ access to the security profile ISFCMD.ODSP.SYSLOG.JESx in the SDSF class (where x is either 2 or 3 representing JES2 or JES3, respectively). SDSF itself uses this class and profile to determine if the TSO userid should be permitted to view the system log within SDSF.
If IOF is specified as the Rule-choice, then a given user can only view the system log if their userid has access to the security class (IOF-class) and resource name (IOF-resource-
profile) specified in the SYSLOG statement. IOF uses this class and profile to determine if the TSO userid should be permitted to view the log through IOF. If IOF is specified as the
Rule-choice, then the system command feature will determine if the system log can be viewed based on whether IOF permits or denies it. IOF has special security class and resource name requirements.
F-18
Compuware Workbench Installation Guide
If SYSTEM is specified, then a given user can only view the system log if their userid has valid security profiles in the JESSPOOL class. Consult your security software documentation for specifics about specifying profiles for JESSPOOL.
Note:
Regardless of the Rule-choice coded on the SYSLOG statement, if the userid is permitted to view the system log under that rule, then JES will always enforce validation of the userid viewing authority based on the userid profiles in the
JESSPOOL class.
The default setting if SYSLOG is not coded:
SYSLOG Y SYSTEM
The format of the SYSLOG statement is:
SYSLOG Y/N Rule-choice IOF-class IOF-resource-profile where Y/N is a single character of Y or N to indicate whether system log viewing capability should be enabled or disabled for all Compuware Workbench users.
where Rule-choice is one of SYSTEM, SDSF, or IOF to specify whether system rules, SDSF rules, or IOF rules are to be followed for verifying if a user can view the system log using
JES Explorer.
where IOF-class is the IOF security class name. The IOF-class must be specified if the rule choice is specified as IOF.
where IOF-resource-profile is the IOF resource name to be validated to determine if a user has IOF system log viewing authority. The IOF-resource-profile must be specified if the rule choice is specified as IOF.
Figure F-19 contains examples of SYSLOG statements as they might be coded in the TP
Configuration File member.
Note:
At least one blank character must precede the active SYSLOG statement. As a practice, code only one SYSLOG statement. Any others should be commented out
(by placing an asterisk (*) in column 1) or removed entirely. If, however, multiple
SYSLOG statements are coded, the last statement scanned is the statement in effect.
Figure F-19. SYSLOG Statement Example
If rule
is IOF:
Enable? Rule Specify If rule is IOF:
(Y/N) Choice Class Specify resource name (44 char max)
----- ------ -------- ---------------------------------------
*SYSLOG N
SYSLOG Y SYSTEM
*SYSLOG Y SDSF
*SYSLOG Y IOF DATASET IOFACF.STA.D.JOBS.JOBN.SYSLOG
In order to determine the proper values to specify for IOF-class and IOF-resource-profile, review your IOF installed settings and IOF documentation. The IOF-class is designated in the A60ACF member of the IOF access control settings. According to IOF documentation the default class setting is DATASET. The IOF-resource-profile to specify is determined from the construction of a global resource name. These names are documented in the IOF
TSO Installation Guide, in the Access Control Reference chapter's section pertaining to global resource names.
CSS TP Configuration Member
F-19
Please refer to “Controlling User Access to the CSS TP's Compuware Workbench
Connection Port” on page B-9 for more information about using and setting up rules to
control this feature.
Code the OIDCARD Statement (Optional)
The OIDCARD statement can limit Compuware Workbench sign-on access to the HCI port to accept sign-ons only from operator identification (OID) card holders. This means that a valid card must be used for Compuware Workbench sign-on. Specifying ONLY means that only a valid OID card can be used for a sign-on and no userid/password entry by Compuware Workbench is accepted. Specifying DEFAULT means that a userid/password or a valid OID card can be accepted. The default setting if OIDCARD is not coded: DEFAULT.
The format of the OIDCARD statement is:
OIDCARD string
string
A string value of
ONLY
or
DEFAULT
.
Figure F-20. Coding the OIDCARD statement
* The OIDCARD statement can limit Workbench sign-on access to the HCI
* port to accept sign-ons only from operator identification (OID) card
* holders. This means that a valid card must be used for Workbench
* sign-on. Specifying ONLY means that only a valid OID card can be
* used for a sign-on and no userid/password entry by the Workbench is
* accepted. Specifying DEFAULT means that a userid/password or a
* valid OID card can be accepted. The default setting if OIDCARD is
* not coded: DEFAULT.
*
*
* Sign-on via
* userid/password
* or OID card Comment
* --------------- -----------------------------------
OIDCARD DEFAULT Choices are ONLY or DEFAULT.
*
*
*
Code the EXCLUDE Statement (Optional)
The optional EXCLUDE statement is used to exclude one or more dataset names from being presented to Compuware Workbench. Any dataset names specified on an
EXCLUDE statement will not be visible in the dataset tree view of Host Explorer within
Compuware Workbench regardless of the filter mask settings.
While system security profiles would normally be used to limit user access to datasets, there are instances where it is desirable to restrict Compuware Workbench access to certain datasets (for example SCLM project datasets), while still allowing users to access those datasets via other non-Compuware Workbench methods such as TSO/ISPF. The
EXCLUDE statement will accomplish this by causing Compuware Workbench not to "see" the excluded datasets while the users still retain whatever security access rights they normally have.
Specify one dataset per EXCLUDE statement. A fully qualified dataset name may be specified or a partial dataset name with an asterisk can also be specified as a simple wildcard indicator. If an asterisk is specified, it must be the last character of the name.
Enter as many EXCLUDE statements as are needed to specify all of the datasets to be
F-20
Compuware Workbench Installation Guide
excluded from Compuware Workbench. Remove the asterisk from column 1 of an
EXCLUDE statement to make it active.
No datasets are excluded if the EXCLUDE statement is not specified. This is the default.
The format of the EXCLUDE statement is:
EXCLUDE datasetname where datasetname
is a fully qualified dataset name or a partial dataset name with a terminating asterisk character.
Figure F-21 shows examples of EXCLUDE statements as they might be coded in the TP
Configuration File member. Note that at least one blank character must precede the
EXCLUDE statements.
Figure F-21. EXCLUDE Statement Example
Dataset name to exclude
-------------------------------------------
EXCLUDE USER4.SOURCE.PDS
EXCLUDE SYS1.*
EXCLUDE PROJECT.SCLM*
Code the CREDENTIALS Statement (Optional)
The optional CREDENTIALS statement is used to enable or disable the ability of
Compuware Workbench users to optionally save their logon credentials in a secure cache on their workstation when connecting to the port defined by this configuration member.
Code ENABLE if you wish to allow users to optionally save their credentials. This is the default action if CREDENTIALS is not coded.
Code DISABLE if you wish to deny the ability for users to save their logon credentials on their workstation. The "Save credentials" checkbox shown during Compuware
Workbench login will be disabled and no login information will be saved on the workstation hard drive.
The default setting if CREDENTIALS is not coded: ENABLE
The format of the CREDENTIALS statement is:
CREDENTIALS action where
action
is either
ENABLE
or
DISABLE
.
Figure F-22 shows an example of the CREDENTIALS statement as it might be coded in
the TP Configuration File member. Note that at least one blank character must precede the CREDENTIALS statement.
Figure F-22. Coding the CREDENTIALS statement
CSS TP Configuration Member
F-21
* Allow saving of
Login credentials Comment
----------------- -----------------------------------
CREDENTIALS DISABLE Choose ENABLE or DISABLE.
Code the NOTIFY Statement (Optional)
The NOTIFY statement allows installations to enable the Job Notification feature. This feature provides for end-of-job notifications that are generated by the NOTIFY=userid JCL parameter to be sent to the user. The NOTIFY=userid JCL parameter is used on JOB statements.
Normally, end-of-job notifications are sent to the TSO user. This remains in effect, regardless of whether the NOTIFY feature is enabled or disabled. Enabling the feature allows a copy of the same end-of-job notification to be sent to the user.
To enable the feature, specify a Y character after the NOTIFY keyword, as shown in the example below. If the NOTIFY statement is not coded, the default value is N and no job notifications will be sent to the user.
The feature also provides an automatic mechanism to purge messages that cannot be delivered to a Workstation user after a set period of days. Messages might be undeliverable because the userid associated with the message never uses Compuware
Workbench, or the userid has not used Compuware Workbench for a period longer than the purge duration period. Purging undeliverable messages reduces overhead and keeps the storage required to maintain the undelivered messages to a reasonable level. The purge duration value is in days. Specify a value between 1 and 999 days. Messages placed in storage for delivery will be purged after the specified number of days elapses without any delivery for that message. Optionally, you may specify a purge duration value of 0 which causes purging to be disabled. Approximately 5900 undelivered messages will consume 1 MB of storage.
Messages are not held across system shutdown or HCI shutdown. When the system or
HCI is restarted, the message queue is empty and collection of end-of-job notifications starts anew.
The format of the NOTIFY statement is:
NOTIFY enable-Y/N
purge-duration-value
enable-Y/N
Is a Y or N character.
purge-duration-value
Is a numeric value in days, between 0 and 999.
F-22
Compuware Workbench Installation Guide
Figure F-23. Coding the NOTIFY statement
**********************************************************************
* JOB NOTIFICATION *
**********************************************************************
*
* The job notification feature can be enabled to allow end-of-job
* notification messages (generated by NOTIFY=userid on the JOB
* statement JCL) to be sent to the appropriate user.
* This feature is disabled if not specified and must be explicitly
* enabled below in order to activate the feature.
*
* The purge duration is used to keep the number of messages that have
* not or cannot be delivered to a manageable level, to reduce the
* storage consumption by undelivered notification messages.
*
*
* Purge unsent
* Enable? messages after
* Y/N x days. x=? Comment
* -------- -------------- -------------------------------
NOTIFY Y 2 Purge value of 0 means no purge
Code the NOTIFYONLY Statement (Optional)
The NOTIFYONLY statement allows an optional reduction of notification messages that are received by other LPARs in a more tightly coupled shared JES spool environment. For example, a job executed on one LPAR may have its notification posted to another LPAR.
Specifying ALL means that notification messages issued by other systems are to be included in the job notification back to Compuware Workbench. Specifying LOCAL means that only job notification messages from the LOCAL LPAR where this configuration is running should be included in the job notifications returned to
Compuware Workbench.
The operating system's routing rules for notification messages are complicated and depend on many variables such as the LPAR that the job was submitted from versus the
LPAR where it executed. In addition, the TSO userid (the userid specified in the JOB card
NOTIFY=user parameter
) being logged on to one LPAR or another (or simply not being logged on at all) influences the routing choice made by the system. Because of these variables, some notification messages may be received by Compuware Workbench for jobs executed on other LPARs even if LOCAL is specified. Despite these occasional exceptions, coding this statement allows for a substantial reduction in notification message traffic sent back to Compuware Workbench users.
The default action if this statement is not specified is ALL.
The format of the NOTIFYONLY statement is:
NOTIFYONLY string
string
Is the value ALL or LOCAL.
CSS TP Configuration Member
F-23
Figure F-24. Coding the NOTIFYONLY statement
*
* The NOTIFYONLY statement allows an optional reduction of notification
* messages that are received by other LPARs in a more tightly coupled
* shared JES spool environment. For example, a job executed on one
* LPAR may have its notification posted to another LPAR. Specifying ALL
* means that notification messages issued by other systems are to be
* included in the job notification back to the Workbench. Specifying
* LOCAL means that only job notification messages from the LOCAL LPAR
* where this configuration is running should be included in the job
* notifications returned to the Workbench.
*
* The operating system's routing rules for notification messages are
* complicated and depend on many variables such as the LPAR that the
* job was submitted from versus the LPAR where it executed. In
* addition, the NOTIFY=user TSO userid being logged on to one LPAR
* or another (or simply not being logged on at all) influences the
* routing choice made by the system. Because of these variables, some
* notification messages may be received by the Workbench for jobs
* executed on other LPARs even if LOCAL is specified.
*
* The default action if this statement is not specified is ALL. It is
* recommended that most customers choose ALL, as this is the value that
* was in effect before this optional parameter was introduced.
*
*
* Receive
* Notifications
* From? Comment
* ----- -------------------------------
NOTIFYONLY ALL Choices are ALL or LOCAL
*
Code the CXTPMSGS Statement (Optional)
The CXTPMSGS statement can be used to reduce the number of messages issued to the
HCI job log as a result of actions by Compuware Workbench users. It is recommended that all messages be displayed initially after first time set up in the event problem diagnosis is required.
- All CXTP messages are issued, QUIET - The frequently issued user activity messages
CXTPMAI013I and CXTPREQ035I are suppressed; all other messages are issued.* NONE
- No CXTP messages are issued.
F-24
Compuware Workbench Installation Guide
Figure F-25. Coding the CXTPMSGS statement
************************************************************************
* MESSAGE SUPPRESSION *
************************************************************************
*
* The CXTPMSGS statement can be used to reduce the number of messages
* issued to the HCI job log as a result of actions by Workbench users.
* It is recommended that all messages be displayed initially after
* first time set up in the event problem diagnosis is required.
* Three settings are available:
*
* FULL - All CXTP messages are issued (DEFAULT).
* QUIET - The frequently issued user activity messages CXTPMAI013I
* and CXTPREQ035I are suppressed; all other messages are
* issued.
* NONE - No CXTP messages are issued.
*
*
* Message
* Setting Comment
* ------- -----------------------------------
CXTPMSGS FULL Choices are FULL, QUIET, or NONE.
*
The format of the CXTPMSGS statement is:
CXTPMSGS string
string
Is the string value of FULL, QUIET, or NONE. Where
FULL enables all CXTP messages to be issued (DEFAULT). QUIET suppresses the frequently issued user activity messages CXTPMAI013I and CXTPREQ035I, but all other messages are issued. NONE suppresses all CXTP messages.
Code the UNITNAME Statement
Some functions performed by Compuware Workbench require the CSS TP to allocate a temporary dataset. The allocation requires the specification of a UNIT esoteric name.
Typical esoteric names used by the different versions of MVS are VIO, SYSDA, and
SYSALLDA. This optional parameter allows the specification of an esoteric unit name if the default name of VIO is not defined or not desired.
The default setting if UNITNAME is not coded:
VIO
The format of the UNITNAME statement is:
UNITNAME unitname where unitname is an esoteric unitname defined to the operating system.
Below is an example of the UNITNAME statement as it might be coded in the TP
Configuration File member. Note that at least 1 blank character must precede the
UNITNAME statement.
CSS TP Configuration Member
F-25
Figure F-26. UNITNAME Statement Example
Unit
Esoteric
Name Comment
--------- -----------------------------------
UNITNAME VIO Default if not specified is VIO
Code the READTIMEOUT Statement
Compuware Workbench has always contained the ability for each user to override the read timeout value for their session. The read timeout value is the number of seconds that Compuware Workbench will wait for a response from the mainframe before assuming something is wrong with the connection and terminating the request and notifying the user. Some installations wish to limit the duration of the timeout period and not allow individual users to exceed that duration.
Use the READTIMEOUT value to specify a number of seconds to be used for the read timeout value for all users connecting to this port. Users will be able to set their read timeout values to a lower value, but will not be able to exceed the value specified here.
Values below 30 are not useful; too short a duration can cause frequent interruptions to the user's session as some requests can take longer to execute than others.
Coding 0 for the READTIMEOUT value means that individual users can continue to set the read timeout value to whatever duration they choose. Coding 0 is consistent with the prior behavior of Compuware Workbench.
The default setting if READTIMEOUT is not coded: 0
The format of the READTIMEOUT statement is:
READTIMEOUT duration where duration is the maximum number of seconds that individual Compuware
Workbench users can choose to specify for their sessions. The range of duration can be from 0 to 999.
Below is an example of the READTIMEOUT statement as it might be coded in the TP
Configuration File member. Note that at least 1 blank character must precede the
READTIMEOUT statement.
Figure F-27. READTIMEOUT Statement Example
Timeout value
0-999 seconds Comment
------------- -----------------------------------
READTIMEOUT 0 Default if not specified is 0
Troubleshooting Job Notification
When job notification appears to be configured properly, that is, the NOTIFY statement is correctly coded in the TP Configuration File member, and the HCI job log is correctly showing that the EMCS console has started but Compuware
F-26
Compuware Workbench Installation Guide
Workbench does not seem to be receiving job notifications. The probably cause of this situation is due to the notification messages being suppressed by the system's
Message Processing Facility (MPF).
When job notification is being processed, the
NOTIFY= parameter
on the JOB card causes JES2 or JES3 to generate a z/OS operator SEND (SE) command which is how
TSO users receive job notification, and how the HCI's EMCS console picks up the notification so it can be routed to Compuware Workbench. If HCI cannot pick up the
SE command message coming over the console, then it will not route it to that
Compuware Workbench user. It is likely that the SE command message was suppressed.
Checking for Message Suppression
Evidence of message suppression is provided in the system hardcopy log (SYSLOG).
All messages appear in the hardcopy log regardless of suppression settings. In the log, many messages may be identified as suppressed by MPF. All messages are identified with an 8-character hexadecimal field starting in column 46. Below is an example SE command message showing the relevant 8-character string in bold.
NC0000000 2100 12163 10:59:22.06 INTERNAL 00000281 SE '10.59.22
JOB02630 $HASP165 TS024MOD ENDED AT MVS1 MAXCC=0000', LOGON,USER=(TS024)
Each numeral in the 8-character string (in this example:
00000281
) is an MPF SYSLOG flag. The numeral meaning of these flags is documented in the IBM manual, z/OS
MVS Planning: Operations (SA22-7601) where the individual settings pertaining to
MPF are described.
In the case of the SE message above, the eighth position is set to
1
. A
1
in the eighth position designates messages to be suppressed by your MPFLSTxx member(s).
In order for the job notification EMCS console facility in the HCI to pick up a suppressed message, it must also be designated as AUTO. AUTO messages can be picked up by automated processors regardless of that message’s suppression setting.
Because Compuware’s HCI EMCS console facility is an automated processor of messages, a message designated as AUTO can be still be picked up.
The SE messages should have a MPF SYSLOG flag setting of
00000290
. The
9
in the
7th position of the MPF flag, is derived by 8 and 1 added together. An 8 means the message is “not serviced by any exit” and the 1 is “automation requested (AUTO)”.
Also, the zero
0
in the 8th position means the MPF suppression indicator is not set.
Therefore, if you are having problems receiving job notifications, Compuware’s recommendation is that you review your MPFLSTxx settings and consult the z/OS
MVS Initialization and Tuning Reference for the MPFLSTxx member. You may need to add an entry to the MPF settings as described below.
If the SE command message is being suppressed for a reason on your system and you wish to keep it that way, then you only need mark the message for automated processing and then the HCI can pick it up properly. This will require an entry in your MPFLSTxx member that looks like this:
SE,SUP(YES),AUTO(YES)
This will cause the message to continue to be suppressed, but the message will be marked for automation, so that automated consoles (like the HCI) can still see it and process it. This MPF setting will cause the MPF SYSLOG flags to be
00000291
, which is acceptable. If you do not care if the message is suppressed or not, then you could also specify
SE,SUP(NO),AUTO(YES) instead (which will be
00000290
). Either way is acceptable.
You can activate the MPFLSTxx member at the console by specifying the
SET MPF=xx operator command.
G-1
Appendix G.
Running a Single HCI to Support Compuware
Workbench and DevEnterprise
Generally, the recommended practice is to use the JCL generated by the Host
Communication Configuration Facility (HCCF)
1
to run a dedicated HCI to support
Compuware Workbench. However, in the case where HCI has already been set up to support DevEnterprise and will be expected to also support Compuware Workbench, follow the instructions in this document.
There are two possible approaches for setting up a single HCI instance to support both
DevEnterprise and Compuware Workbench.
• Approach 1 converts the existing HCI to version 3.0, thus making it possible the use of the HCIXML facility to configure HCI
• Approach 2 continues to use the HCI configuration macro assembly method and the
FDBDRPL DD to supply HCI configuration (conversion to HCI 3.0 is optional, though recommended).
Approach 1 — Configuring an Existing HCI Image using HCIXML
Step 1. Convert macros to XML
1. Add a
//HCIPRINT DD SYSOUT=*
statement to your HCI execution JCL.
2. Update the HCI Authorized load library to point to the HCI 3.0 SLHCAUTH load library.
3. Execute the HCI as normal.
4. Terminate the HCI and examine the HCIPRINT data set.
5. Select and copy the XML code in the HCIPRINT data set, starting with the
<HCICNFIG>
statement through the
</HCICNFIG>
statement into a member
(HCIMCNFG) of your Parmlib data set. Be sure you copy all of the XML.
6. Add a
//HCIXML DD
statement, pointing to the member of your Parmlib data set you just created. If you name the member of this data set
HCIMCNFG
, you do not need to change the
CONFIG= operand
on the EXEC statement PARM.
7. Add a
//HCIERR DD SYSOUT=*
statement to the HCI execution JCL.
8. Execute the HCI.
9. Note the HCIERR data set contains a listing of all the XML statements along with error messages describing any invalid entries. At the end of this data set, if no errors have been detected, message HC1860 NO STATEMENTS FLAGGED IN THE XML
DOCUMENT will be printed.
G
App G
1. Compuware Workbench release 3.2 introduced the Host Communication Configuration Facility
(HCCF) for setting up HCI in support of Topaz, per each LPAR.
G-2
Compuware Workbench Installation Guide
Step 2. Add CSS TP definition XML to the new HCI configuration XML in
HCIMCNFG
1. Edit the xxxxXML member of the HCI Parmlib generated by the HCCF.
2. Copy the
<HCICNPCB
element from the xxxxXML and insert it after the last
<HCICNPCB element in the HCIMCNFG member of the HCI Parmlib referenced by your running
HCI JCL.
3. Copy the
<HCICNTPT
element from the xxxxXML and insert it after the last
<HCICNTPT element in the HCIMCNFG member of the HCI Parmlib referenced by your running
HCI JCL.
Step 3. Add the HCI parmlib member for the CSS TP and customize the JCL
1. Because this is an existing HCI image, the HCI parmlib data set (pointed to by the
HCIPARM DD
statement) should already exist. Copy the
CXTP01
member (or the
TPNAME that was used when configuring the CSS TP for Compuware Workbench) from the HCI Parmlib generated by the HCCF into the production HCI Parmlib.
2. Add the TPCONFIG DD statement from your Compuware Workbench HCI to the JCL for your original HCI.
3. Check the STEPLIB and make sure all datasets from Compuware Workbench HCI are included in the STEPLIB of your old HCI.
4. Execute the HCI.
Approach 2 — Continue to use the HCI Configuration Macro Assembly
Method
Step 1. Convert XML to macros
1. Edit the xxxxXML member of the HCI Parmlib generated by the HCCF.
2. Copy the
<HCICNPCB
element from the xxxxXML, convert the XML to macros by a. Removing the
<
character .
b. Adding a comma at the end of each text statement and a non-blank continuation character (
*
) in column 72, except the last parameter (
TYPE=LOCAL
).
c. Insert the converted XML (now a macro) after the last HCICNPCB macro in your existing HCI configuration.
3. Copy the
<HCICNTPT
element from the xxxxXML, convert the XML to macros by a. Removing the
<
character b. Adding a comma at the end of each text statement and a non-blank continuation character (
*
) in column 72, except the last parameter (
TPNAME=xxxxxx
) c. Insert the converted XML (now a macro) after the last HCICNTPT macro in your existing HCI configuration.
4. Reassemble and link the HCI configuration macros updating the //FDBDRPL configuration load library.
5. Add the TPCONFIG DD statement from your Compuware Workbench HCI to the JCL for your original HCI.
6. Check the STEPLIB and make sure all datasets from Compuware Workbench HCI are included in the STEPLIB of your old HCI.
7. Execute the HCI.
Running a Single HCI to Support Compuware Workbench and DevEnterprise
G-3
Step 2. (Optional) Convert to HCI 3.0
1. Update the HCI Authorized load library to point to the HCI 3.0 SLHCAUTH load library.
2. Add the TPCONFIG DD statement from your Compuware Workbench HCI to the JCL for your original HCI.
3. Check the STEPLIB and make sure all datasets from Compuware Workbench HCI are included in the STEPLIB of your old HCI.
G-4
Compuware Workbench Installation Guide
H-1
Appendix H.
Compuware Maintenance Utility
The Compuware Maintenance Utility (CMU) is a program executed through JCL that, by default, generates reports listing all PTFs currently applied to a particular system, for all specified Compuware mainframe products. With the addition of an optional control file
(available from Frontline (
http://go.compuware.com
)), the CMU can produce reports that include a list of PTFs that have not been applied or are otherwise missing. The contents
of the control file (Figure H-2) are placed into a dataset or in stream JCL for the CMU to
scan.
The CMU is distributed in the License Management System loadlib (SLMSLOAD).
Note:
The CMU was introduced in License Management System (LMS) via a PTF in May
2013. Since then, the CMU control file format was adjusted and minor enhancements added along with more supported mainframe products. PTF
LMF0068 is now required. Make sure all current maintenance is applied to LMS before attempting to use the CMU. Refer to the Compuware products listed in the "z/OS, Compatibility and Supported Releases Table" on FrontLine for any additional product PTF requirements.
The CMU processes a simple list of dataset names that it will scan and report on. The utility is able to scan the system link list for CMU supported Compuware product datasets. It will also scan the STEPLIB DD concatenation of the JCL as well as the datasets specified for SYSIN. The combined scan results from these sources will be presented in the output reports.
JCL Required to Execute the CMU
Several DD statements are required to execute the CMU and some are optional. Sample
JCL is provided in the LMS samples library (SLMSCNTL) member LMMNTUTL. The general JCL structure required is shown below:
Figure H-1. General JCL Structure
//JOBCARD JOB CLASS=A
//MAINT EXEC PGM=LMMNTUTL
//STEPLIB DD DISP=SHR,DSN=COMPWARE.MLMSNNN.SLMSLOAD
//SYSPRINT DD SYSOUT=*
//REPORT DD SYSOUT=*
//ALLPTFS DD SYSOUT=*
//PRODUCTS DD DISP=SHR,DSN=COMPWARE.LM.MAINTCTL(LMMNTCTL)
//SYSIN DD *
product.dataset.name1
product.dataset.name2
product.dataset.namen
/*
//
Required Datasets
STEPLIB — this dataset must point to the License Management System SLMSLOAD library where the CMU resides. Any other Compuware product dataset may
H-2
Compuware Workbench Installation Guide
optionally be specified in the STEPLIB DD concatenation for scanning and reporting on their contents as well.
SYSPRINT — a required SYSOUT dataset. This output dataset will contain any error messages resulting from the scan.
REPORT — a required SYSOUT dataset. This output dataset will contain the summary "one-page" report for each product dataset found in STEPLIB, SYSIN, or the system link list.
ALLPTFS — a required SYSOUT dataset. This output dataset will contain the full list of applied or missing PTFs for each product dataset found in STEPLIB, SYSIN, or the system link list.
PRODUCTS — this optional input dataset contains the control file information for the CMU. The CMU uses the information in this dataset to determine the highest levels of maintenance that are available for each product. When this dataset is available and processed successfully, the CMU will produce reports based on PTFs that are not yet applied (missing), by product.
When the PRODUCTS DD statement is not present in the JCL, or if the associated dataset was not in the proper format and could not be processed, the CMU will produce the default report based on all of the PTFs that are applied, by product.
The control file input specified by PRODUCTS can be in stream data in the JCL, or be a PDS dataset member. If the control information resides in a physical dataset, the dataset must be 80-byte fixed length records, any valid blocksize.
The format of the control file data is discussed below in “Control File Format”
SYSIN - this is an optional, but recommended, input dataset. This dataset specifies a list of Compuware product dataset load libraries that are to be scanned. If this dataset is coded, the product dataset names should be specified in columns 1 through
44, one dataset per line.
Control File Format
The control file, provided on Frontline (
http://go.compuware.com
), under License
Management System, contains a list of Compuware products and release numbers, which includes a list of all the currently available PTFs for each.
The control file is used by the CMU to determine which PTFs have not yet been applied.
That determination is based on what PTFs are actually applied compared to the inclusion list of all the PTFs that are currently available.
The control file will be updated on Frontline each time maintenance is released for the participating products. Be sure to check for updates before running the utility to ensure the reporting is current.
An example of the control file input is in Figure H-2.
Compuware Maintenance Utility
H-3
Figure H-2. Example of the Control File input
******************************
***** PTF-INCLUDE-LIST *****
******************************
UPDATED 2013 SEP 23
** Compuware Shared Services
*
PRODUCT CX 08.05.00
CXM0001-CXM0097 CXM0099-CXM0101 CXM0103-CXM0141 CXM0143-CXM0408
PRODUCT CX 08.06.00
CXN0001-CXN0088 CXN0090-CXN0526 CXN0528-CXN0559 CXN0561-CXN0575
CXN0577-CXN0593
PRODUCT CX 08.07.00
CXO0001-CXO0071 CXO0073-CXO0080 CXO0082-CXO0105 CXO0108-CXO0418
CXO0420-CXO0480 CXO0482-CXO0741 CXO0743
PRODUCT CX 08.08.00
CXP0001-CXP0119 CXP0121-CXP0180 CXP0182-CXP0287 CXP0289-CXP0446
CXP0448
PRODUCT CX 09.00.00
CXQ0001-CXQ0046 CXQ0048-CXQ0049 CXQ0052
** License Management System
*
PRODUCT LM 04.00.00
LMF0000-LMF0061
** Abend-AID Common
*
PRODUCT AC 12.03.00
* FMID MKAZ231
ACB001Y-ACB002Y ACB004Y ACB006Y ACB008Y-ACB009Y ACB012Y ACB014Y-ACB016Y
ACB020Y ACB022Y ACB027Y-ACB030Y ACB032Y ACB034Y ACB037Y ACB043Y
ACB045Y ACB050Y ACB053Y ACB055Y ACB057Y ACB060Y-ACB061Y ACB065Y
* FMID OKAZ231
ACB004Z ACB006Z ACB008Z-ACB009Z ACB020Z ACB022Z ACB028Z-ACB030Z
** Abend-AID
*
PRODUCT AA 12.03.00
* FMID MPAA230
AAB005Y AAB007Y AAB010Y AAB013Y AAB015Y AAB019Y-AAB023Y AAB026Y
AAB028Y AAB031Y-AAB032Y AAB035Y AAB045Y-AAB048Y AAB050Y-AAB052Y
AAB054Y AAB060Y AAB065Y-AAB066Y
* FMID OPAA230
AAB020Z AAB022Z AAB032Z
** Abend-AID for CICS
*
PRODUCT CF 12.03.00
* FMID MKFX231
CFB003J CFB011J CFB015J CFB018J CFB020J-CFB022J CFB025J CFB044J
CFB050J-CFB051J CFB065J
* FMIDS NKFX232-NKFX236
CFB017*-CFB018* CFB021* CFB024* CFB033* CFB036* CFB038* CFB041*
CFB049*-CFB050* CFB065*
* FMID OKFX231
CFB020A CFB022A
** Fault Analytics
*
PRODUCT MF 12.03.00
MFB002J
******************************
*** END-PTF-INCLUDE-LIST ***
******************************
The control file specifies all CMU supported Compuware mainframe products back to a reasonable release level, typically no more than two releases back from current (n-2).
Lines within the control file that contain an asterisk (*) in column 1 are considered comments and are ignored.
H-4
Compuware Workbench Installation Guide
If the CMU is unable to parse the control file information because the format is incorrect or because the information was garbled as a result of download, it will report an error message to SYSPRINT, then produce the default report containing only applied PTFs.
Report Output
Figure H-3 shows the output for the summary report when the CMU is executed without a
control file (no PRODUCTS DD statement). Following this summary report, is an
example of the output showing the list of PTFs applied (Figure H-4).
Further examples are shown providing a sample of the CMU output with a control file
present (Figure H-5 and Figure H-6).
In the reports, if a product dataset was specified in one of the input sources but it could not be identified as a CMU Supported Compuware product dataset (no xxRELSMP-like module), a double-question mark (
??
) will appear in the report for the product code and an
N/A
will appear in the description and release.
If a product dataset was scanned successfully, but that product was not represented in the control file input, then a double-question mark (
??
) will appear in the highest available
PTF column because no control information was available. When this condition occurs, the CMU will also be unable to determine the number of missing PTFs.
Figure H-3. Summary report without a PRODUCTS DD control file
Compuware Product Maintenance at a Glance
for specified datasets
Highest #
Product PTF PTFs
Product code and name Release Applied Applied Source Library
---------------------------- -------- ------- ------- -------- ---------------------
-------------
CX Shared Services 08.07.00 CXO0486 481 STEPLIB CX.PROD.R080700.SLCXLOAD
HC Host Communic. Interface 02.50.00 HCA0045 44 SYS2.HC250.S1.AUTHLIB
?? N/A N/A SYS2.HC250.S2.AUTHLIB
CX Shared Services 08.08.00 CXP0187 186 CX.PROD.R080800.ALLPTFS.SLCXLOAD
CX Shared Services 08.05.00 CXM0413 404 EXPLICIT CX.PROD.R080500.SLCXLOAD
FA File-AID/MVS 09.03.01 FA9A011 9 FA.PUBLIC.V9R3M1T.MXFA931.SXFAAUTH
XT Xpediter/TSO 09.01.00 XTI0056 56 XT.PROD.MLXT910.ALLPTFS.SLXTLOAD
XT Xpediter/TSO 07.06.00 XTF0164 163 XT.PROD.MLXT760.ALLPTFS.SLXTLOAD
XD Xpediter/CICS 09.01.00 XDNL068 66 XD.R090100.NMXD910.SMXD065L
XD Xpediter/CICS 08.03.00 XDMI207 205 XD.R080300.MMXD839.SMXD063L
XG Xpediter/Xchange 05.00.00 XGB0014 14 XG.PROD.MLXG500.ALLPTFS.SLXGLOAD
XG Xpediter/Xchange 04.00.00 XGA0077 71 XG.PROD.MLXG400.ALLPTFS.SLXGLOAD
XV Xpediter/Code Coverage 03.01.00 XVC0041 40 XV.PROD.MLXV310.ALLPTFS.SLXVLOAD
XV Xpediter/Code Coverage 03.00.00 XVB0033 33 XV.PROD.MLXV300.ALLPTFS.SLXVLOAD
CX Shared Services 08.08.00 CXP0142 140 LINKLIST
FA File-AID/MVS 09.03.01 FA9A028 20
Compuware Maintenance Utility
H-5
Figure H-4. Full report without a PRODUCTS DD control file
Compuware Product Maintenance Applied
for specified datasets
CX Shared Services 08.07.00
-------------------------------------------------------------------------
From: STEPLIB DSN: CX.PROD.R080700.ALLPTFS.SLCXLOAD
PTFs applied:
CXO0001 CXO0002 CXO0003 CXO0004 CXO0005 CXO0006 CXO0007 CXO0008 CXO0009
CXO0010 CXO0011 CXO0012 CXO0013 CXO0014 CXO0015 CXO0016 CXO0017 CXO0018
CXO0019 CXO0020 CXO0021 CXO0022 CXO0023 CXO0024 CXO0025 CXO0026 CXO0027
CXO0028 CXO0029 CXO0030 CXO0031 CXO0032 CXO0033 CXO0034 CXO0035 CXO0036
CXO0037 CXO0038 CXO0039 CXO0040 CXO0041 CXO0042 CXO0043 CXO0044 CXO0045
CXO0046 CXO0047 CXO0048 CXO0049 CXO0050 CXO0051 CXO0052 CXO0053 CXO0054
CXO0055 CXO0056 CXO0057 CXO0058 CXO0059 CXO0060 CXO0061 CXO0062 CXO0063
CXO0064 CXO0065 CXO0066 CXO0067 CXO0068 CXO0069 CXO0070 CXO0071
CXO0073 CXO0074 CXO0075 CXO0076 CXO0077 CXO0078 CXO0079
CXO0082 CXO0083 CXO0084 CXO0085 CXO0086 CXO0087 CXO0088 CXO0089 CXO0090
CXO0091 CXO0092 CXO0093 CXO0094 CXO0095 CXO0096 CXO0097 CXO0098 CXO0099
CXO0100 CXO0101 CXO0102 CXO0103 CXO0104 CXO0105 CXO0108
CXO0109 CXO0110 CXO0111 CXO0112 CXO0113 CXO0114 CXO0115 CXO0116 CXO0117
CXO0118 CXO0119 CXO0120 CXO0121 CXO0122 CXO0123 CXO0124 CXO0125 CXO0126
CXO0127 CXO0128 CXO0129 CXO0130 CXO0131 CXO0132 CXO0133 CXO0134 CXO0135
..
.. these lines omitted for brevity
..
CXO0460 CXO0461 CXO0462 CXO0463 CXO0464 CXO0465 CXO0466 CXO0467 CXO0468
CXO0469 CXO0470 CXO0471 CXO0472 CXO0473 CXO0474 CXO0475 CXO0476 CXO0477
CXO0478 CXO0479 CXO0480 CXO0481 CXO0482 CXO0483 CXO0484 CXO0485 CXO0486
Figure H-5. Summary report with a Product DD control File
Compuware Product Maintenance at a Glance
for specified datasets
Highest Highest #
Product PTF PTF PTFs
Product code and name Release Applied Avail Missing Source Library
---------------------------- -------- ------- ------- -------- -------- ----
CX Shared Services 08.07.00 CXO0488 CXO0488 2 STEPLIB CX.PROD.R080700.SLCXLOAD
HC Host Communic. Interface 02.50.00 HCA0045 HCA0045 0 SYS2.HC250.S1.AUTHLIB
?? N/A N/A ?? SYS2.HC250.S2.AUTHLIB
CX Shared Services 08.08.00 CXP0171 CXP0189 23 CX.PROD.R080800.SLCXLOAD
CX Shared Services 08.05.00 CXM0408 CXM0413 15 EXPLICIT CX.PROD.R080500.LOADLIB
FA File-AID/MVS 09.03.01 FA9A027 FA9A028 2 FA.PUBLIC.V9R3M1T.MXFA931.SXFAAUTH
XT Xpediter/TSO 09.01.00 XTI0057 XTI0042 0 XT.PROD.MLXT910.ALLPTFS.SLXTLOAD
XT Xpediter/TSO 07.06.00 XTF0164 XTI0164 1 XT.PROD.MLXT760.ALLPTFS.SLXTLOAD
XD Xpediter/CICS 09.01.00 XDNL068 XD*L070 4 XD.R090100.NMXD910.SMXD065L
XD Xpediter/CICS 09.01.00 XDML068 XD*L070 4 XD.R090100.MMXD910.SMXD064L
XD Xpediter/CICS 08.03.00 XDMI207 XD*I207 2 XD.R080300.MMXD830.SMXD063L
XW DevEnterprise 05.03.00 XWE0026 ?? X2.PROD.MLXW530.ALLPTFS.SLXWLOAD
XG Xpediter/Xchange 05.00.00 XGB0015 XGB0015 0 XG.PROD.MLXG500.ALLPTFS.SLXGLOAD
XG Xpediter/Xchange 04.00.00 XGA0077 XGA0077 6 XG.PROD.MLXG400.ALLPTFS.SLXGLOAD
XV Xpediter/Code Coverage 03.01.00 XVC0041 XVC0041 1 XG.PROD.MLXG310.ALLPTFS.SLXGLOAD
XV Xpediter/Code Coverage 03.00.00 XVB0033 XVB0033 0 XG.PROD.MLXG300.ALLPTFS.SLXGLOAD
CX Shared Services 08.08.00 CXP0142 CXP0189 49 LINKLIS
FA File-AID/MVS 09.03.01 FA9A028 FA9A028 1
}
H-6
Compuware Workbench Installation Guide
Figure H-6. Full report with a PRODUCTS DD control file
Compuware Product Maintenance Requirements
for specified datasets
CX Shared Services 08.07.00
-------------------------------------------------------------------------
From: STEPLIB DSN: CX.PROD.R080700.ALLPTFS.SLCXLOAD
PTFs missing:
CXO0080 CXO0081
HC Host Communic. Interface 02.50.00
-------------------------------------------------------------------------
From: STEPLIB DSN: SYS2.HC250.S1.AUTHLIB
PTFs missing:
NONE
CX Shared Services 08.08.00
-------------------------------------------------------------------------
From: STEPLIB DSN: CX.PROD.R080800.SLCXLOAD
PTFs missing:
CXP0086 CXP0164 CXP0168 CXP0169 CXP0170 CXP0172 CXP0173 CXP0174 CXP0175
CXP0176 CXP0177 CXP0178 CXP0179 CXP0180 CXP0181 CXP0182 CXP0183 CXP0184
CXP0185 CXP0186 CXP0187 CXP0188 CXP0189
CX Shared Services 08.05.00
-------------------------------------------------------------------------
From: EXPLICIT DSN: CX.PROD.R080500.LOADLIB
PTFs missing:
CXM0013 CXM0070 CXM0119 CXM0120 CXM0121 CXM0122 CXM0142 CXM0236 CXM0294
CXM0298 CXM0409 CXM0410 CXM0411 CXM0412 CXM0413
FA File-AID/MVS 09.03.01
-------------------------------------------------------------------------
From: EXPLICIT DSN: FA.PUBLIC.V9R3M1T.MXFA931.SXFAAUTH \
PTFs missing:
FA9A007 FA9A028
I-1
Appendix I.
Compuware Workbench Messages and Codes
A number of return and reason codes can be issued by the TP during use of Compuware Workbench. In most cases these codes reflect a user error, such as an invalid password or some other invalid specification. Sometimes however, the cause of the error is more severe and may indicate a configuration issue or internal error.
Whenever a return code is issued, there will be an associated reason code. The return code is always a decimal number and denotes the area of the TP that is reporting the failure. For example, return code 8 is a security error (having to do with userids and passwords), and return code 164 is a VTAM Open error.
The reason codes that are reported as a result of any return code are simply the system return code from the function that was requested. For example, in the case of return code 164 (the VTAM Open error), the reason code value is the return code from the OPEN macro. Therefore, by referencing the appropriate documentation for that function or macro you will be able to locate the return code from that function and determine what action to take.
Below is a list of all of the return codes that could be issued by the TP. When the associated reason code is related to a system function, the appropriate documentation reference will be stated. In a few cases, the reason codes are internal to the TP. For these reason codes the causes will be listed here.
Return Codes
RC=0
Reason=X'00000000'
Meaning: The function requested was successfully processed.
Action: None
Reference: None
RC=4
Reason=X'rrrrrrrrr'
Meaning: Errors occurred while parsing the Xpediter/Eclipse TP configuration file.
Action: Refer to the HCI's message log (JESMSGLG) to see related error messages describing the records in the configuration file that are in error. For reason=4, the portions of the configuration file that were not in error were successfully processed however.
Meaning Reason Code
Dec Hex
4 00000004
8 00000008
Errors parsing configuration file.
Could not open configuration file. Possible missing TPCONFIG DD statement in the HCI jobstream.
Reference: None
RC=8
Reason=X'rrrrrrrr'
Meaning: User security could not be established when attempting to sign-on from Xpediter/Eclipse to the mainframe.
I-2
Compuware Workbench Installation Guide
Action: Retry the sign-on attempt after correcting the cause identified in the reason code:
Meaning
8
9
10
4
5
6
7
1
2
3
Reason Code
Dec Hex
00000001
00000002
00000003
00000004
00000005
00000006
00000007
00000008
00000009
0000000A
Password not correct.
Password expired.
New password invalid.
User ID expired.
User ID not recognized.
User ID revoked.
Group not recognized.
User ID not valid for group.
User ID revoked from group.
Unspecified error returned from HCI CW_SLSE.
Reference: None.
RC=12
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_FARE failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=16
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_FARE failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=20
Reason=X'rrrrrrrr'
Meaning: Load failed for an entry point.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=24
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_RNU failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=28
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_RNU failed.
Compuware Workbench Messages and Codes
I-3
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=32
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_SGD failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=36
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_SGD failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=40
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_ACC failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=44
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_ACC failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=48
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_UNR failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=52
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_UNR failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=56
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_DDE failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=60
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_DDE failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
I-4
Compuware Workbench Installation Guide
Reference: None
RC=64
Reason=X'rrrrrrrr'
Meaning: Error occurred trying to receive data from Xpediter/Eclipse. This error can occur frequently and could be caused by a lost connection, or by the user turning off the workstation or abnormally exiting Eclipse.
Action: Reconnect and retry your session. If the error persists, contact Compuware Customer Support and provide the reason code.
Reference: None
RC=68
Reason=X'rrrrrrrr'
Meaning: Error occurred trying to receive data from Xpediter/Eclipse. This error can occur frequently and could be caused by a lost connection, user turned off workstation or exited Eclipse.
Action: Reconnect and retry your session. If the error persists, contact Compuware Customer Support and provide the reason code.
Reference: None
RC=72
Reason=X'rrrrrrrr'
Meaning: No data was received. This error occurred trying to receive data from Xpediter/Eclipse. This error can occur frequently and could be caused by a lost connection, user turned off workstation or exited Eclipse.
Action: Reconnect and retry your session. If the error persists, contact Compuware Customer Support and provide the reason code.
Reference: None
RC=76
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_CFMD failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=80
Reason=X'00000000'
Meaning: Incomplete data received. The buffer used to receive data has overflowed.
Action: This is an internal error. If it persists, contact Compuware Customer Support.
Reference: None
RC=84
Reason=X'00000000'
Meaning: The CICS system connection name that was selected in the connection dialog box of Xpediter/Eclipse was not found in the TP configuration file.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=88
Reason=X'00000000'
Meaning: The port number specified in the configuration file is not numeric.
Action: The port numbers in the configuration file must be numeric and one to five digits in length. Correct the error and refresh the configuration file or restart the HCI and retry the connection.
Reference: None
Compuware Workbench Messages and Codes
I-5
RC=92
Reason=X'00000000'
Meaning: The TSO system connection name that was selected in the connection dialog box of Xpediter/Eclipse was not found in the TP configuration file.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=96
Reason=X’00000000’
Meaning: The site-specific (customer-supplied) job submission exit routine (CXTXSUBX) has denied the submit request.
Action: Contact your system installer to determine why the site-specific exit routine has denied the submission request.
Reference: None
RC=100
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_SLS failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=104
Reason=X'rrrrrrrr'
Meaning: Internal load failed for CW_FARE.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=108
Reason=X'eeeeiiii'
Meaning: During the submission of a job stream, dynamic allocation failed for the internal reader.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=112
Reason=X'00000000'
Meaning: A job was submitted from a dataset, but the dataset name specified contained blanks.
Action: Verify that the dataset name was correctly selected. If the error persists, this is probably an internal error.
Contact Compuware Customer Support.
Reference: None
RC=116
Reason=X'eeeeiiii'
Meaning: During the submission of a job stream, dynamic allocation failed for the selected user dataset containing the job stream.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
I-6
Compuware Workbench Installation Guide
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
RC=120
Reason=X'rrrrrrrr'
Meaning: During job submission, an OPEN macro failed trying to open the user specified dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=124
Reason=X'rrrrrrrr'
Meaning: During job submission, an OPEN macro failed trying to open the internal reader.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=128
Reason=X'ccccrrrr'
Meaning: An abend occurred during the execution of the TP.
Action: Some abends are caused by user actions (see Reference, below). Other abends could be internal errors. If the abend code is not listed below, it is a probable internal error. Contact Compuware Customer Support and provide the reason code. For abends listed below, take the action indicated.
Reference: z/OS MVS System Codes SA22-7626. The reason code is in two parts: cccc is the abend completion code supplied by the system, and rrrr is the abend reason code also supplied by the system. Typical reason codes are:
0013 0018 - Abend S013-18 Dataset member is not found
0001 0004 - Abend S001-4 You attempted to list the members of a non-partitioned dataset
0001 0001 - Abend S001-1 General I/O error processing a dataset
0913 0038 - Abend S913-38 You do not have authority to access this dataset.
RC=132
Reason=X'rrrrrrrr'
Meaning: When attempting to initiate a connection with CICS, the INITAPI macro failed.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server IP Sockets Application Programming Guide and Reference SC31-8788.
Appendix B, Return Codes. The reason code rrrrrrrr is the ERRNO value from the macro instruction.
RC=136
Reason=X'rrrrrrrr'
Meaning: When attempting to initiate a connection with CICS, the SOCKET macro failed.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server IP Sockets Application Programming Guide and Reference SC31-8788.
Appendix B, Return Codes. The reason code rrrrrrrr is the ERRNO value from the macro instruction.
RC=140
Reason=X'rrrrrrrr'
Meaning: When attempting to initiate a connection with CICS, the CONNECT macro failed.
Action: The likely cause of this return code is that the CICS region you are attempting to connect with is not active.
Compuware Workbench Messages and Codes
I-7
Reference: z/OS Communications Server IP Sockets Application Programming Guide and Reference SC31-8788.
Appendix B, Return Codes. The reason code rrrrrrrr is the ERRNO value from the macro instruction. Common reason codes:
0000003D - (decimal ERRNO 61) The CICS region is not active or not accepting connections.
RC=144
Reason=X'rrrrrrrr'
Meaning: Internal call to CW_SEND failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=160
Reason=X'rrrrrrrr'
Meaning: An error occurred during the parsing of the data received from Xpediter/Eclipse.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=164
Reason=X'rrrrrrrr'
Meaning: While trying to initiate a debugging session with Xpediter/TSO, an error occurred opening the VTAM ACB.
Action: Probable specification error of VTAM APPL definitions. Several possible causes exist:
"APPL definition not defined
"APPL not specified in the TP configuration file
"APPL in use by another application
"APPL requires a password (no APPL password support existing in Xpediter/Eclipse)
"APPL access restricted by local security rules
Look up the reason code in the reference below to determine the cause. If the cause cannot be corrected locally, contact Compuware Customer Support and provide the reason code. Common reason codes and their meanings:
00000014 - Insufficient storage to open the ACB
00000024 - User is not authorized to use the APPL
00000052 - VTAM is shutting down
00000058 - The APPL is already in use by another program or user
0000005A - The APPL was not defined to VTAM
Reference: IBM’s z/OS Communications Server SNA Programming (see Chapter 13, "Conventions and Descriptions of
VTAM macroinstructions"). After the description of the OPEN macro a list of possible return codes is listed. The reason code rrrrrrrr is the OPEN return code.
RC=168
Reason=X'00000000'
Meaning: While connected to TSO, TSO has terminated. The TSO session may have abended or was canceled by the system operator, or has timed out (wait time limit exceeded).
Action: Review the system log to determine the reason that your TSO session may have terminated.
Reference: None
RC=172
Reason=X'00000000'
Meaning: When attempting to connect to TSO, it was determined that the user was already logged on to a TSO session via another connection or terminal.
Action: Choose a different TSO userid for the connection, or log off of the active TSO session.
I-8
Compuware Workbench Installation Guide
Reference: None
RC=176
Reason=X'00000000'
Meaning: When attempting to connect to TSO, system security rejected the user's password.
Action: Specify the correct password and retry the connection.
Reference: None
RC=180
Reason=X'00000000'
Meaning: When attempting to connect to TSO, system security rejected the user's userid. The userid has been revoked due to excessive invalid logon attempts.
Action: Contact your local system security administrator for correction.
Reference: None
RC=184
Reason=X'xxxxxxxx'
Meaning: When attempting to connect to TSO, a logon prompt was not received by the TP. Commonly received reason codes:
00000000 - Expected prompt for userid was not received. The expected prompts are IKJ56700A ENTER USERID, or,
ACF82004 ACF2, ENTER LOGON ID -
00000004 - After the userid is entered, the next message is expected to be an IKJ or ACF message. This return code occurs if one of those possibilities did not occur.
00000008 - An unknown message was received
0000000C - The receive buffer is exhausted.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code. The Technical
Support representative will probably request a trace so that the messages causing difficultly logging on can be identified and a solution devised.
Reference: None
RC=188
Reason=X'0000rtfb'
Meaning: During a connection with TSO, a VTAM RPL error occurred.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: IBM’s z/OS Communications Server SNA Programming (see Appendix B "Return Codes and Sense Fields for RPL-based Macro Instructions"). The reason code rt is the RPL return code (RTNCD) and the fb value is the RPL feedback code (FDB2).
RC=192
Reason=X'rrrrrrrr'
Meaning: While attempting to attach the EMCS console task to collect job notifications, the TP was unable to obtain the local lock from the system.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the SETLOCK macro and its list of return codes. The reason code rrrrrrrr is the return code from SETLOCK.
RC=193
Reason=X'rrrrrrrr'
Meaning: While attempting to attach the TP control task during initial TP start up, the TP was unable to obtain the local lock from the system.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Compuware Workbench Messages and Codes
I-9
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the SETLOCK macro and its list of return codes. The reason code rrrrrrrr is the return code from SETLOCK.
RC=196
Reason=X'rrrrrrrr'
Meaning: While attempting to attach the EMCS console task to collect job notifications, the TP was unable to schedule the necessary IRB to the main HCI task.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the SCHEDIRB macro and its list of return codes. The reason code rrrrrrrr is the return code from SCHEDIRB.
RC=197
Reason=X'rrrrrrrr'
Meaning: While attempting to attach the TP control task during initial start-up, the TP was unable to schedule the necessary IRB to the main HCI task.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the SCHEDIRB macro and its list of return codes. The reason code rrrrrrrr is the return code from SCHEDIRB.
RC=200
Reason=X'ccccrrrr'
Meaning: When sending data from the mainframe to Xpediter/Eclipse, an error occurred during the conversion of the data from EBCDIC to UTF-8.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: IBM’s z/OS Support for Unicode: Using Unicode Services SA22-7649 (see Appendix B, "Return Codes"). The reason code consists of two parts: cccc is the return code from the conversion service, and rrrr is the reason code from the conversion service.
RC=204
Reason=X'ccccrrrr'
Meaning: When receiving data from Xpediter/Eclipse, an error occurred during the conversion of the data from
EBCDIC to UTF-8.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: IBM’s z/OS Support for Unicode: Using Unicode Services SA22-7649 (see Appendix B, "Return Codes"). The reason code consists of two parts: cccc is the return code from the conversion service, and rrrr is the reason code from the conversion service.
RC=208
Reason=X'00000000'
Meaning: While attempting to connect to TSO, no more APPL entries were available. All of the APPL entries are in use.
Action: Contact your system installer. Add additional APPL definitions to VTAM and then add those new APPL names to the TP configuration file.
Reference: ECC Installation and Customization Guide. Refer to the section titled "Creating and Managing the
Xpediter/Eclipse TP Configuration File".
RC=212
Reason=X'rrrrrrrr'
Meaning: While attempting to retrieve a partitioned dataset member list, an OPEN macro failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
I-10
Compuware Workbench Installation Guide
RC=220
Reason=X’00000000’
Meaning: A physical I/O error occurred attempting to process the specified dataset.
Action: The dataset cannot be read or written using standard access methods. There is something physically wrong or corrupted with the dataset. Select a different dataset or create a new dataset for processing.
Reference: None.
RC=224
Reason=X’00000000’
Meaning: Early end of file occurred while reading a dataset or member in ISPF “packed” format. Either the data was not really in packed format, or part of the data is corrupted such as unpacking cannot succeed.
Action: Verify if the dataset is usable via ISPF. If ISPF cannot properly unpack the data then the data is probably unusable.
If the dataset can be browsed or edited via ISPF properly, then the file is probably not corrupted. Host Explorer is unable to process the data. Contact Compuware Customer Support. You may be requested to provide traces and/or or a copy of the dataset so that the problem can be determined and a solution made available.
Reference: None.
RC=236
Reason=X'00000000'
Meaning: Errors occurred while parsing the Xpediter/Eclipse TP configuration file.
Action: Refer to the HCI's message log (JESMSGLG) to see related error messages describing the records in the configuration file that are in error.
Reference: None
RC=240
Reason=X'rrrrrrrr'
Meaning: While attempting to write JCL records to the internal reader during a job submission request, an RPL error was encountered on a PUT macro.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: IBM’s z/OS DFSMS Macro Instructions for Datasets SC26-7408 (see Chapter 3, "VSAM Macro Return Codes and Reason Codes", in the section titled "Record Management Return and Reason Codes"). The reason code rrrrrrrr is the RPLRTNCD value.
RC=244
Reason=X'00000000'
Meaning: An Xpediter/Eclipse user is not signed in.
Action: Reestablish a connection to the mainframe and properly sign in with a userid and password before attempting any mainframe access.
Reference: None
RC=248
Reason=X'eeeeiiii'
Meaning: During the retrieval of JES spool output, dynamic unallocation failed for the JES spool dataset.
Action: This is a dynamic unallocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=252
Reason=X'ssssrrrr'
Compuware Workbench Messages and Codes
I-11
Meaning: During a request to retrieve the status of a specific job, an error occurred accessing the JES subsystem interface.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: Refer to system dataset 'SYS1.AMODGEN' or 'SYS1.MODGEN', member IEFSSCS. The reason code is two parts: ssss is the return code issued by the IEFSSREQ macro, and rrrr is the reason code value in the SSOBRETN field.
RC=256
Reason=X’rrrrrrrr’
Meaning: While attempting to retrieve JES spool output, an OPEN macro failed opening the JES spool dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code. A commonly received reason code:
000C 0098 – The user does not have sufficient access authority to view this JES dataset. Access is controlled by the system security software using a JESSPOOL class profile to restrict access.
RC=260
Reason=X'rrrrrrrr'
Meaning: During the retrieval of JES job list, an error occurred accessing the JES subsystem interface.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Using the Subsystem Interface SA22-7642. Within Chapter 3, refer to the section titled
"Extended Status Function Call - SSI Function Code 80". Refer to the return and reason codes issued by the IEFSSREQ macro. The reason code rrrrrrrr is the return code issued by the IEFSSREQ macro.
RC=264
Reason=X'ssssrrrr'
Meaning: During the retrieval of JES job list, an error occurred accessing the JES subsystem interface.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Using the Subsystem Interface SA22-7642. Within Chapter 3, refer to the section titled
"Extended Status Function Call - SSI Function Code 80". Refer to the return and reason codes issued by the IEFSSREQ macro. The reason code is two parts: ssss is the return code contained in the SSOBRETN field, and rrrr is the reason code value in the STATREAS field.
RC=268
Reason=X'00000000'
Meaning: When attempting to obtain a job list from the JES spool, no owner or prefix value was specified.
Action: Owner, or prefix, or both, must be specified. Then retry the request.
Reference: None
RC=272
Reason=X'ssssrrrr'
Meaning: During the retrieval of JES output, an error occurred accessing the JES subsystem interface.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Using the Subsystem Interface SA22-7642. Within Chapter 3, refer to the section titled
"Extended Status Function Call - SSI Function Code 80". Refer to the return and reason codes issued by the IEFSSREQ macro. The reason code is two parts: ssss is the return code contained in the SSOBRETN field, and rrrr is the reason code value in the STATREAS field.
RC=276
Reason=X’ssssrrrr’
Meaning: During the retrieval of JES output, an error occurred accessing the JES subsystem interface. Some of the output datasets were not selectable.
I-12
Compuware Workbench Installation Guide
Action: Output datasets may be considered not selectable if they are not in a held SYSOUT class, or if the output is no longer in the held queue, or if security restrictions disallow retrieval of an output dataset. Additionally, the datasets are not considered selectable if the output is in HOLD status (that is, deliberately held by a system operator command). If the output does not fit into one of the categories above, then this could be an internal error. Contact
Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Using the Subsystem Interface SA22-7642. Within Chapter 3, refer to the section titled
“SYSOUT Application Program Interface (SAPI) – SSI Function Code 79”. Refer to the return and reason codes issued by the IEFSSREQ macro. The reason code is two parts: ssss is the return code contained in the SSOBRETN field, and rrrr is the reason code value in the SSS2REAS field.
For output selection errors described under Action above, the commonly received reason codes are:
0004 00F0 – No output matched any of the selection criteria.
0004 00F4 – An output dataset matched the selection criteria, but was not selectable for one of the reasons stated in Action, above.
RC=280
Reason=X'00000000'
Meaning: The TP is not APF-authorized and therefore cannot issue JES subsystem interface calls.
Action: Add the dataset containing the TP load module (CXTPMAIN) to the APF dataset list.
Reference: None.
RC=284
Reason=X'00000000'
Meaning: During the retrieval of JES output, none of the output datasets were selectable.
Action: Output datasets may be considered not selectable if they are not in a held SYSOUT class, or if the output is no longer in the held queue, or if security restrictions disallow retrieval of an output dataset. Additionally, the datasets are not considered selectable if the output is in HOLD status (that is, deliberately held by a system operator command).
Reference: None.
RC=288
Reason=X'00000000'
Meaning: During the retrieval of JES output, some output datasets were not selectable.
Action: Output datasets may be considered not selectable if they are not in a held SYSOUT class, or if security restrictions disallow retrieval of an output dataset. Any remaining output that was selectable is returned normally.
Reference: None.
RC=292
Reason=X'ssssrrrr'
Meaning: During the retrieval of JES output, an error occurred accessing the JES subsystem interface.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Using the Subsystem Interface SA22-7642. Within Chapter 3, refer to the section titled
"SYSOUT Application Program Interface (SAPI) - SSI Function Code 79". Refer to the return and reason codes issued by the IEFSSREQ macro. The reason code is two parts: ssss is the return code contained in the SSOBRETN field, and rrrr is the reason code value in the SSS2REAS field.
RC=296
Reason=X'eeeeiiii'
Meaning: During the retrieval of JES output, dynamic allocation failed for JES output dataset..
Action: This is a dynamic allocation failure. This error is not normally preventable by a user and is considered to be an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
Compuware Workbench Messages and Codes
I-13
RC=300
Reason=X'00000000'
Meaning: The Xpediter/TSO Multi-Batch Facility (MBF) is not installed on this system.
Action: Please notify your system installer to install this feature.
Reference: Xpediter/TSO Installation Guide.
RC=304
Reason=X'00000000'
Meaning: The Xpediter/TSO Multi-Batch Facility (MBF) is not initialized.
Action: Please notify your system installer to initialize the feature.
Reference: Xpediter/TSO Installation Guide.
RC=308
Reason=X'00000000'
Meaning: The Xpediter/TSO Multi-Batch Facility (MBF) is installed and initialized but it is not active.
Action: Please notify your system installer to initialize the feature.
Reference: Xpediter/TSO Installation Guide.
RC=312
Reason=X'rrrrrrrr'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to open the Multi-Batch file has failed.
Action: The most likely cause of this error is that the user does not have READ access to the Multi-Batch file. Please also see RC=316. If this is not the case this is probably an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=316
Reason=X'rrrrrrrr'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to write to the multi-batch file has failed.
Action: If the reason code is X'00000010' this indicates that the user does not have UPDATE access to the Multi-Batch file. If this is not the cause, then this is a probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: Internal Compuware return code from Multi-Batch I/O module ADSIS315.
RC=320
Reason=X'rrrrrrrr'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to write to the Multi-Batch internal requests table has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: Internal Compuware return code from module XPMSTBLD.
RC=324
Reason=X'rrrrrrrr'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to close to the Multi-Batch file has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the CLOSE macro and its list of return codes. The reason code rrrrrrrr is the CLOSE return code.
I-14
Compuware Workbench Installation Guide
RC=328
Reason=X'rrrrrrrr'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to load Multi-Batch support routines has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: Load for Multi-Batch I/O module ADSIS315.
RC=332
Reason=X'rrrrrrrr'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to load Multi-Batch support routines has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: Load for XPMSTBLD.
RC=333
Reason=X'rrrrrrrr'
Meaning: The HCI hosting the CSS TP has either a configuration parameter mismatch or the HCI is not up to date with maintenance. The TP will not operate correctly. The return code is from CW_GSOK.
Action: Ensure that the HCI configuration's HCICNAMB macro has the HPNS= parameter specifying CURR and that HCI
PTF HCA0031 is applied. After applying the PTF, you must ensure that you reassemble the HCI configuration macros using the SYS1.SMPMTS dataset in the assembly's SYSLIB DD statement concatenation. The PTF changes an HCI macro, and in order to pick up the change, the SMPMTS library must be used.
Reference: None.
RC=336
Reason=X'00000000'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to load Multi-Batch module
XPMNTRT has failed. Module XPMNTRT was not linked into HCI module CXTPMAIN.
Action: Have the system installer re-link the TP module CXTPMAIN. If the link-edit appears correct, contact
Compuware Customer Support.
Reference: MBF module XPMNTRT address is zero.
RC=340
Reason=X'rrrrrrrr'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to open the Compuware Shared
Profile (CSPF) dataset has failed.
Action: Internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None.
RC=344
Reason=X'eeeeiiii'
Meaning: During the retrieval of a dataset or member, dynamic allocation failed for the selected user dataset.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
RC=348
Reason=X'eeeeiiii'
Compuware Workbench Messages and Codes
I-15
Meaning: During the retrieval of a member list of a partitioned dataset, dynamic allocation failed for the selected user dataset.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
RC=352
Reason=X'eeeeiiii'
Meaning: During an attempt to save data to a user dataset, dynamic allocation failed for that user dataset.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
RC=356
Reason=X'rrrrrrrr'
Meaning: An error occurred during the parsing of the JCL stream received from Xpediter/Eclipse during a job submission request.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None
RC=360
Reason=X'eeeeiiii'
Meaning: During error recovery, dynamic allocation failed for the dump dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=364
Reason=X'rrrrrrrr'
Meaning: During error recovery, an attempt to open the dump dataset has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=368
Reason=X’00000000’
Meaning: When initiating an Xpediter/Eclipse debugging session via TSO, the connected TSO session encountered a
JCL error.
Action: Probable user error. Check that the correct procedure name was specified. Alternately, contact the system installer to determine if the specified procedure contains a JCL error.
Reference: See section “Install the TSO Logon Procedure” on page 8-4.
RC=372
Reason='000000rr'
I-16
Compuware Workbench Installation Guide
Meaning: For Compuware Workbench users authenticated by a digital certificate only, when initiating an
Xpediter/Eclipse debugging session via TSO, the PassTicket service was unable to establish a PassTicket for this user.
Action: Probable RACF or other security software configuration error. The security software must be correctly set up to process PassTickets as described by the RACF Administrator's Guide. The TP requires a profile consisting of
TSO+SMFid be defined to the PTKTDATA class as described in the manual reference below.
Reference: IBM’s z/OS Security Server: RACF Administrator's Guide SA22-7683 (see Chapter "General Resources",
Section "Using the Secured Sign-on Function" and "The RACF PassTicket"). Common return codes from this function:
04- Incorrect PassTicket.
08 - No PTKTDATA profile found for the application (TSO+SMFid)
0C - No task or address space ACEE found, and the ACEE pointer was not specified on the input parameter list.
10 - TP is not APF-authorized.
14 - The RACF PTKTDATA class is not active.
RC=376
Reason=X'00000000'
Meaning: When initiating an Xpediter/TSO debugging session via TSO, the TSO session encountered a JCL error.
Action: Probable user error. Check that the correct procedure name was specified. Alternately, contact the system installer to determine if the procedure contains a JCL error.
Reference: See section “Install the TSO Logon Procedure” on page 8-4.
RC=380
Reason=X'rrrrrrrr'
Meaning: A recall attempt has failed for a migrated dataset.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: IBM’s z/OS DFSMShsm Managing Your Own Data SC35-0420 (see Chapter 22, "Using DFSMShsm User
Macros", in section "Register Usage for Return Codes"). The reason code rrrrrrrr is the ARCHRCAL macro return code.
00000002 - Dataset was not migrated
00000064 - DFSMS is not active on the system
00000192 - Dataset name not found
00000193 - Dataname name was * or blank
00000806 - Error linking to DFSMS service
00000zzz -Any other value: recall function failed
RC=384
Reason=X'00000000'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to use the Compuware Shared
Profile (CSPF) dataset has failed. An internal record could not be located.
Action: Probable user error. The CSPF dataset must be initialized prior to use. Verify with the system installer that initialization has occurred and if not, have the system installer perform the initialization.
Reference: See section “Create the Compuware Shared Profile Dataset” on page 8-1.
RC=388
Reason=X'00000000'
Meaning: During the initiation of an Xpediter/TSO debugging session, an attempt to close Compuware Shared Profile
(CSPF) dataset has failed.
Action: Probable internal error. Contact Compuware Customer Support.
Reference: See section “Create the Compuware Shared Profile Dataset” on page 8-1.
Compuware Workbench Messages and Codes
I-17
RC=392
Reason=X'00000000'
Meaning: When initiating an Xpediter/TSO debugging session via TSO, the TSO session encountered could not locate the XPCP load module.
Action: Probable user error. Check that the correct procedure name was specified. When a procedure that was not tailored for Xpediter/Eclipse use is specified, the JCL in that procedure may not allocate the correct Xpediter/TSO supporting libraries, resulting in "XPCP COMMAND NOT FOUND". Alternately, contact the system installer to determine if the procedure contains the correct Xpediter/TSO datasets.
Reference: See section “Install the TSO Logon Procedure” on page 8-4.
RC=393
Reason=X'00000000'
Meaning: When initiating an Xpediter/TSO debugging session on a remote LPAR, the contact request timed out.
Action: Probable internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=394
Reason=X'00000000'
Meaning: When initiating an Xpediter/TSO debugging session on a remote LPAR, the corresponding Compuware
Workbench socket could not be located.
Action: Probable internal error. Contact Compuware Customer Support for assistance.
Reference: None.
Explanation: RC=396
Reason=X'00000000'
Meaning: When initiating an Xpediter/TSO debugging session, a version incompatibility error was encountered.
Action: The connection port to the mainframe is running an older version of Compuware Shared Services, and that version cannot support this level of Xpediter/Eclipse. Contact your system installer.
Reference: None.
RC=400
Reason=X'rrrrrrrr'
Meaning: When attempting to initiate a connection with CICS, the WRITE macro failed.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
Reference: IBM’s z/OS Communications Server IP Sockets Application Programming Guide and Reference SC31-8788 (see
Appendix B, "Return Codes"). The reason code rrrrrrrr is the ERRNO value from the macro instruction.
RC=404
Reason=X'rrrrrrrr'
Meaning: When attempting to initiate a connection with CICS, the WRITE macro failed.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server IP Sockets Application Programming Guide and Reference SC31-8788.
Appendix B, Return Codes. The reason code rrrrrrrr is the ERRNO value from the macro instruction.
RC=408
Reason=X'rrrrrrrr'
Meaning: When attempting to initiate a connection with CICS, the READ macro failed.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
I-18
Compuware Workbench Installation Guide
Reference: z/OS Communications Server IP Sockets Application Programming Guide and Reference SC31-8788.
Appendix B, Return Codes. The reason code rrrrrrrr is the ERRNO value from the macro instruction.
RC=412
Reason=X'rrrrrrrr'
Meaning: When attempting to initiate a connection with CICS, the READ macro failed.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server IP Sockets Application Programming Guide and Reference SC31-8788.
Appendix B, Return Codes. The reason code rrrrrrrr is the ERRNO value from the macro instruction.
RC=416
Reason=X'0000rrrr'
Meaning: When attempting to initiate a connection with CICS, Xpediter/CICS rejected the connection attempt.
Action: Probable user error. Look up the reason code in the reference below to determine the corrective action. If no corrective action can be determined, contact Compuware Customer Support.
Reference: This reason code is issued by Xpediter/CICS. The reason code rrrr is the reason code from that product.
Reason Code
Dec Hex
04 0004
Meaning
Listener Definition Error. Listener Definition FORMAT=ENHANCED Required.
08
12
16
20
24
28
32
36
40
44
48
52
0008
000C
0010
0014
0018
001C
0020
0024
0028
002C
0030
0034
Length of initial contact data for ENHANCED Listener Must Be 61.
The first 5 bytes of the initial contact data sent to DBUGSOCK must be the transaction code associated with program DBUGSOCK, usually XSOC, (the comma is required).
No semicolon (:) found in the initial contact data. A semicolon is required to delineate the IP address of the workstation from the listener port of the workstation
No slash (/) found in the initial contact data. A slash is required to delineate the listener port of the workstation from the conversation mode (E=EBCDIC, A=ASCII, more accurately UTF-8) that all traffic on the socket is to use.
The conversation mode (the byte following the slash (/) must be E or A.
No IP address of the workstation specified.
The IP address of the workstation could not be converted from text format to internal format. The actual reason code in the message will be 6:mmmm where mmmm represents the Errno returned by the sockets PTON call. You will have to refer to the Errno section of the IP CICS Sockets Guide for a meaning of these values.
No listener port of the workstation was specified.
The listener port of the workstation specified is not numeric.
The listener port specified > 65535.
Commarea Length Error. The length of the initial connection data is not 61 bytes.
Initial Contact Data Invalid. A preliminary scan of the initial connection data has found a syntax error.
Compuware Workbench Messages and Codes
I-19
108
112
116
120
124
128
96
100
104
80
84
88
92
68
72
76
Reason Code
56
60
64
132
0070
0074
0078
007C
0080
0038
Meaning
Transaction Mismatch. The socket definition or configuration file definition is incorrect. The code, usually XSOC, should be identical in the socket definition and the configuration file.
003C
0040
0044
0048
004C
0050
0054
0058
005C
0060
0064
0068
Transaction Is Not Defined To CICS. The Xpediter/CICS API Connection transaction specified in the socket definition and configuration file, usually XSOC, has not been defined to CICS.
Inquire for Transaction Failed. The user is not authorized to execute an EXEC
INQUIRE TRANSACTION call. The userid assigned prior to logon or the default userid specified, must at the minimum, have execute authority for EXEC INQUIRE
TRANSACTION, EXEC INQUIRE PROGRAM, and EXEC VERIFY commands.
Transaction / Program Mismatch. The Xpediter/CICS API Connection transaction definition, usually XSOC, must be associated with program DBUGSOCK.
Transaction Is Not Enabled. The Xpediter/CICS API Connection transaction, usually
XSOC, must have a status of enabled.
Transaction Must Run In TASKDATAKEY(CICS). The Xpediter/CICS API Connection transaction, usually XSOC, must have TASKDATAKEY (CICS) specified.
Transaction Must Run In TASKDATALOC(ANY). The Xpediter/CICS API Connection transaction, usually XSOC, must have TASKDATALOC (ANY) specified.
Transaction Is Secured. The Xpediter/CICS API Connection transaction, usually
XSOC, should not be secured, i.e. RESSEC (NO) should be specified.
Program DBUGSOCK Is Not Defined To CICS.
Inquire For Program DBUGSOCK Failed. The user is not authorized to execute an
EXEC INQUIRE PROGRAM call. The userid assigned prior to logon or the default userid specified, must at the minimum, have execute authority for EXEC INQUIRE
TRANSACTION, EXEC INQUIRE PROGRAM, and EXEC VERIFY commands
Program DBUGSOCK Is Not Defined As Assembler.
Program DBUGSOCK Is Not Enabled. The Xpediter/CICS API Connection program
DBUGSOCK must have a status of enabled.
Program DBUGSOCK Must Run In EXECKEY(CICS). The Xpediter/CICS API
Connection program DBUGSOCK must have EXECKEY(CICS) specified.
006C
0084
Program DBUGSOCK Must Run In DATALOC (ANY). The Xpediter/CICS API
Connection program DBUGSOCK must have DATALOC (ANY) specified.
Userid/Password Verification Failed.
Xpediter/CICS API Requires CICS Enhanced Listener.
Xpediter/CICS API Must Be KC (Task Control) Started.
Xpediter/CICS API Currently Only Supports Sockets IPv4.
Inquire for Transaction XPGD Failed, NOTAUTH. The user is not authorized to execute an EXEC INQUIRE TRANSACTION call. The userid assigned prior to logon or the default userid specified, must at the minimum, have execute authority for
EXEC INQUIRE TRANSACTION, EXEC INQUIRE PROGRAM, and EXEC VERIFY commands.
Transaction XPGD must be defined. This transaction is used to ensure a user is authorized to use the Xpediter/CICS component of Xpediter/Eclipse.
I-20
Compuware Workbench Installation Guide
Reason Code
136
140
144
148
152
156
160
164
168
172
176
180
184
188
192
196
0088
Meaning
Transaction XPGD has not been associated with program XDPIMIRS. This transaction is used to ensure a user is authorized to use the Xpediter/CICS APIand must be associated with program XDPIMIRS.
008C
0090
0094
0098
009C
00A0
00A4
00A8
00AC
00B0
00B4
00B8
00BC
00C0
00C4
Inquire for Transaction XPGD Failed. The EXEC INQUIRE TRANSACTION (XPGD) call failed. The userid assigned prior to logon or the default userid specified, must at the minimum, have execute authority for EXEC INQUIRE TRANSACTION, EXEC
INQUIRE PROGRAM, EXEC SYSTEM SECURITYMGR, and EXEC VERIFY commands.
Transaction XPGD Is Not Enabled. This transaction is used to ensure a user is authorized to use the Xpediter/CICS APIand must have a status of enabled.
Transaction Must Run In TASKDATAKEY(CICS). This transaction is used to ensure a user is authorized to use the Xpediter/CICS APIand must have TASKDATAKEY (CICS) specified.
Transaction Must Run In TASKDATALOC(ANY). This transaction is used to ensure a user is authorized to use the Xpediter/CICS APIand must have TASKDATALOC (ANY) specified.
The EXEC CICS QUERY SECURITY TRANSACTION(XPGD) failed. Users authorized to the use Xpediter/CICS APImust also have authority to issue EXEC CICS QUERY commands.
The user does not have READONLY security for transaction XPGD. This is an indication of unauthorized access or security for transaction XPGD being set to incorrect values.
Program XDPIMIRS Is Not Defined To CICS.
Inquire For Program XDPIMIRS Failed. The user is not authorized to execute an
EXEC INQUIRE PROGRAM call.
Program XDPIMIRS Is Not Defined As Assembler.
Program XDPIMIRS Is Not Enabled. Program XDPIMIRS must have a status of enabled.
Program XDPIMIRS Must Run In EXECKEY(CICS).
Program XDPIMIRS Must Run In DATALOC (ANY).
Inquire to determine if security is active in the CICS region failed. The userid assigned prior to logon or the default userid specified, must at the minimum, have execute authority for EXEC INQUIRE TRANSACTION, EXEC INQUIRE PROGRAM,
EXEC SYSTEM SECURITYMGR, and EXEC VERIFY commands.
Userid does not have authorization to access the CICS region. EXEC CICS VERIFY returned ESM (external security manager) 'NOT AUTH' code.
Userid may not access the CICS region. EXEC CICS VERIFY returned ESM (external security manager) unknown rejection code. Message MXDSK0065E was written to the CICS CSMT transient data queue with the ESM return and reason codes.
RC=420
Reason=X'rrrrrrrr'
Meaning: When attempting to initiate a connection with CICS, the GETHOSTID macro failed.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server IP Sockets Application Programming Guide and Reference SC31-8788.
Appendix B, Return Codes. The reason code rrrrrrrr is the ERRNO value from the EZASMI GETHOSTID macro instruction.
Compuware Workbench Messages and Codes
I-21
RC=424
Reason=X'00000000'
Meaning: When attempting to launch a debug session with CICS, it was determined that the IP number of the CICS region is not the same IP number of the host system that is running the HCI to which you are connected.
Action: Probable user error. The CICS region used for debugging must be running on the same system as the HCI that is connected with Host Explorer and Xpediter/Eclipse.
Reference: None.
RC=432
Reason=X'rrrrrrrr'
Meaning: When attempting to get a list of datasets via the dataset mask, a catalog error occurred.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
Reference: IMB’s z/OS DFSMS Managing Catalogs SC26-7409 (see Appendix C, "Catalog Search Interface User's
Guide"). The reason code rrrrrrrr is the return code value from the IGGCSI00 macro instruction.
RC=436
Reason=X'rrrrrrrr'
Meaning: When attempting to get a list of datasets via the dataset mask, a catalog error occurred.
Action: Probable internal error. However, in some cases you may be able to correct the error by looking up the cause.
Otherwise, contact Compuware Customer Support and provide the reason code.
Reference: IBM’s z/OS DFSMS Managing Catalogs SC26-7409 (see Appendix C, "Catalog Search Interface User's
Guide".) The reason code rrrrrrrr is the value contained in the CSICRETN (Catalog Data Return Code) field.
RC=440
Reason=X'00000000'
Meaning: No dataset names were found to match the supplied dataset mask.
Action: Probable user error. Retry the request with a less restrictive dataset mask.
Reference: None.
RC=444
Reason=X'00000000'
Meaning: When attempting to submit a JCL stream, no valid JOB card was found.
Action: Probable user error. Correct the JCL stream and ensure the JOB card is valid and retry the request. The minimum JOB card is: //JOBNAME JOB
Reference: None.
RC=448
Reason=X'rrrrrrrr'
Meaning: An attempt to open a partitioned dataset for the purpose of reading the directory has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=452
Reason=X'eeeeiiii'
Meaning: While attempting to determine the properties of the selected dataset, dynamic allocation has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
I-22
Compuware Workbench Installation Guide
RC=456
Reason=X'rrrrssss'
Meaning: An attempt to rename a member of a partitioned dataset has failed.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the STOW macro and its list of return codes. The reason code rrrr is the STOW return code and ssss is the STOW reason code.
00040000 - New member name already exists, choose a different name.
00080000 - The member selected for rename does not exist
RC=460
Reason=X'rrrrssss'
Meaning: An attempt to delete a member of a partitioned dataset has failed.
Action: Check the reason codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the STOW macro and its list of return codes. The reason code rrrr is the STOW return code and ssss is the STOW reason code.
00080000 - The member selected for deletion does not exist
RC=464
Reason=X'eeeeiiii'
Meaning: During the retrieval of information about a dataset, dynamic allocation failed.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=468
Reason=X'rrrrrrrr'
Meaning: During the retrieval of information about a dataset, an OBTAIN macro failed when trying to locate the format-1 DSCB.
Action: In the unlikely event this error occurs, check the reason code for one of the following:
00000004 - The volume where the dataset resides is not mounted
00000008 - The dataset could not be found on the volume's VTOC
0000000C - I/O error reading the format-1 DSCB
00000010 - Invalid work area pointer. This is an internal error, contact Compuware Customer Support
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 1 subsection "Accessing the VTOC with
DASDM Macros" and refer to the return codes for OBTAIN / CAMLST SEARCH. The reason code returned is the register
15 return code from the OBTAIN macro.
RC=472
Reason=X'rrrrrrrr'
Meaning: During the retrieval of information about a dataset, an OBTAIN macro failed when trying to locate the format-3 DSCB.
Action: In the unlikely event this error occurs, check the reason code for one of the following:
00000004 - The volume where the dataset resides is not mounted
00000008 - The dataset could not be found on the volume's VTOC
0000000C - I/O error reading the format-1 DSCB
Compuware Workbench Messages and Codes
I-23
00000010 - Invalid work area pointer. This is an internal error, contact Compuware Customer Support
00000014 - The F3 DSCB address specified is not within the boundaries of the VTOC. Contact Compuware
Customer Support.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 1 subsection "Accessing the VTOC with
DASDM Macros" and refer to the return codes for OBTAIN / CAMLST SEEK. The reason code returned is the register 15 return code from the OBTAIN macro.
RC=476
Reason=X'rrrrssss'
Meaning: During the retrieval of information about a dataset, a DEVTYPE macro failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to the chapter on "Using System Macro
Instructions", subsection "Obtaining I/O Device Characteristics" and refer to the return codes for DEVTYPE. The reason code values rrrr and ssss are the return and reason codes from the DEVTYPE macro, respectively.
RC=481
Reason=X'00000000'
Meaning: When attempting to launch a user initiated procedure, the procedure name was missing or invalid.
Action: Correct the procedure name in the request. The procedure must conform to z/OS rules for JCL procedure names and exist in a system proclib.
Reference: None.
RC=482
Reason=X'00000000'
Meaning: When attempting to launch a user initiated procedure, the program name name was missing or invalid.
Action: Correct the program name in the request. The program name must conform to z/OS rules for load module names.
Reference: None.
RC=483
Reason=X'rrrrssss'
Meaning: When attempting to launch a user initiated procedure in a new address space, the address space creation failed.
Action: Probable internal error. Contact Compuware Customer Support for assistance and supply the reason code.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the ASCRE macro and its list of return codes and reason codes. The reason code rrrr is the return code from ASCRE, and the reason code ssss is the reason code from ASCRE.
RC=484
Reason=X'rrrrrrrr'
Meaning: An attempt to open a partitioned dataset for the purpose of renaming or deleting a member has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=488
Reason=X'eeeeiiii'
Meaning: An attempt to dynamically allocate a partitioned dataset for the purpose of renaming or deleting a member has failed.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
I-24
Compuware Workbench Installation Guide
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=492
Reason=X'rrrrrrrr'
Meaning: An attempt to enqueue on a partitioned dataset member for the purpose of deleting that member has failed.
Action: The member is probably in use by the same or a different user. Check the reason code below to determine possible causes. If the code is not listed, this is a probable environmental error and should be resolved by your system programming personnel. The dataset member is probably enqueued by another job elsewhere in the system.
00000004 -Exclusive control of the member could not be obtained
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the ENQ macro and its list of return codes. The reason code rrrrrrrr is the ENQ return code.
RC=496
Reason=X'rrrrrrrr'
Meaning: An attempt to enqueue on a partitioned dataset member for the purpose of renaming that member has failed.
Action: The member is probably in use by the same or a different user. Check the reason code below to determine possible causes. If the code is not listed, this is a probable environmental error and should be resolved by your system programming personnel. The dataset member is probably enqueued by another job elsewhere in the system.
00000004 -Exclusive control of the member could not be obtained
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the ENQ macro and its list of return codes. The reason code rrrrrrrr is the ENQ return code.
RC=504
Reason=X'rrrrrrrr'
Meaning: An attempt to initialize the Compuware Shared Profile Dataset (CSPF) has failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None.
RC=508
Reason=X'rrrrrrrr'
Meaning: An attempt to open the Compuware Shared Profile Dataset (CSPF) has failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None.
RC=512
Reason=X'rrrrrrrr'
Meaning: An attempt to read the Compuware Shared Profile Dataset (CSPF) has failed.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None.
RC=516
Reason=X'eeeeiiii'
Meaning: An attempt to dynamically allocate the Compuware Shared Services SLCXTABL dataset has failed.
Action: This is a dynamic allocation failure. In order to eliminate the probable causes, have your system installer check the following:
"Ensure that the Compuware Shared Profile (CSPF) dataset has been allocated and initialized with the name of the ISPF table member containing the Compile Facility compiler parameters. Initializing the CSPF dataset with this information
specify the dataset name of the Shared Services SLCXTABL dataset.
Compuware Workbench Messages and Codes
I-25
"Ensure that the Compile Facility member AAUTCTBL member exists within the Shared Services SLCXTABL dataset
Otherwise, look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=520
Reason=X'rrrrrrrr'
Meaning: An attempt to open a partitioned dataset for the purpose of importing the Compile Facility defaults has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=524
Reason=X'00000000'
Meaning: Not enough buffer space exists to hold the Compile Facility defaults.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code. Alternately, the system installer could attempt to delete the defaults in the Compuware Shared Services SLCXTABL member (delete
AAUTCTBL) and rebuild them, and this could alleviate the problem with a more compact defaults member.
Reference: Compuware ECC Installation and Customization Guide, in section "CSS Customization", Step 4: Create the Compile Information Table.
RC=532
Reason=X'eeeeiiii'
Meaning: During a request to compress a partitioned dataset, an attempt to dynamically allocate that dataset has failed.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=536
Reason=X'eeeeiiii'
Meaning: During a request to compress a partitioned dataset, an attempt to dynamically obtain allocation information for that dataset has failed.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=540
Reason=X'eeeeiiii'
Meaning: During a request to compress a partitioned dataset, an attempt to dynamically allocate that dataset has failed.
Action: The dataset is in use and exclusive control could not be obtained. Exclusive control is required in order to initiate compression. Retry the request when the dataset is not in use. This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=544
Reason=X'rrrrrrrr'
Meaning: A request was made to compress a dataset that is not partitioned.
I-26
Compuware Workbench Installation Guide
Action: This is a user error. Only partitioned datasets can be compressed.
Reference: The reason code is the DSORG value for the requested dataset.
RC=548
Reason=X'eeeeiiii'
Meaning: During a request to compress a partitioned dataset, an attempt to dynamically allocate the SYSPRINT dataset for the IEBCOPY utility has failed.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=552
Reason=X'rrrrssss'
Meaning: An attempt to locate a dataset during a rename request has failed
Action: The specified dataset name may have been deleted since the last refresh of the dataset mask. Refresh the dataset mask; if the dataset is still shown retry the request. If the request still fails, contact Compuware Customer
Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Retrieving Information by
Dataset Name" and refer to the return codes for LOCATE / CAMLST NAME. The reason code values rrrr and ssss are the return and reason codes from the LOCATE macro, respectively.
RC=556
Reason=X'rrrrssss'
Meaning: An attempt to rename a dataset has failed
Action: The dataset selected for rename is in use by another user or task. If the reason code is X'00080007', or
X'000400FF' then that is the cause. Retry the request when the dataset is not in use. For other reason codes, contact
Compuware Customer Support and provide the code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 2 subsection "RENAME and CAMLST
Macro Specification" and refer to the return codes for the RENAME macro. The reason code values rrrr and ssss are the return and reason codes from the RENAME macro, respectively.
RC=560
Reason=X'rrrrrrrr'
Meaning: During a request to rename, delete, catalog, or uncatalog a dataset, an OBTAIN macro failed when trying to locate the format-1 DSCB.
Action: In the unlikely event this error occurs, check the reason code for one of the following:
00000004 - The volume where the dataset resides is not mounted
00000008 - The dataset could not be found on the volume's VTOC
0000000C - I/O error reading the format-1 DSCB
00000010 - Invalid work area pointer. This is an internal error, contact Compuware Customer Support
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 1 subsection "Accessing the VTOC with
DASDM Macros" and refer to the return codes for OBTAIN / CAMLST SEARCH. The reason code returned is the register
15 return code from the OBTAIN macro.
RC=564
Reason=X'rrrrrrrr'
Meaning: A request to uncatalog a dataset has failed.
Action: In the unlikely event this error occurs, check the reason code for the following value:
00FF0001 - The dataset is SMS managed and cannot be uncataloged.
Compuware Workbench Messages and Codes
I-27
SMS managed datasets cannot be uncataloged. This is normal operation of the system and not an error by
Xpediter/Eclipse. For all other codes, this is a probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Using non-VSAM Data Set
Catalog Entries" and refer to the return codes for the catalog processor. The reason code returned is the register 15 return code from the CATALOG macro. The X'00FF0001' is a Compuware internal return code denoting SMS management and is not documented in this z/OS reference manual.
RC=568
Reason=X'rrrrrrrr'
Meaning: A request to catalog a dataset has failed.
Action: Verify that the volume specified is mounted and available for use. Verify that the dataset name being cataloged is not already a duplicate of an existing name. Look up the reason code in the reference below to determine the cause. Contact Compuware Customer Support for assistance if necessary.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Using non-VSAM Data Set
Catalog Entries" and refer to the return codes for the catalog processor. The reason code returned is the register 15 return code from the CATALOG macro.
RC=572
Reason=X'rrrrrrrr'
Meaning: During a request to catalog a dataset, the UCBSCAN macro has failed trying to determine the device type of the requested volume.
Action: Possible user error. The most likely cause is that the volume specified in the catalog request does not exist or is not mounted. If the volume is online and available and this error occurs, contact Compuware Customer Support for assistance and provide the reason code.
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the UCBSCAN macro and its list of return and reason codes. The reason code values rrrr and ssss are the return and reason codes from the UCBSCAN macro, respectively.
RC=576
Reason=X'rrrrssss'
Meaning: An attempt to delete a dataset has failed
Action: The dataset selected for deletion may be in use by another user or task. If the reason code is X'00080007', or
X'000400FF' then that is the cause. Retry the request when the dataset is not in use. For other reason codes, contact
Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 2 subsection "SCRATCH and CAMLST
Macro Specification" and refer to the return codes for the SCRATCH macro. The reason code values rrrr and ssss are the return and reason codes from the SCRATCH macro, respectively.
RC=580
Reason=X'rrrrrrrr'
Meaning: A dataset has been deleted, and a follow-on request to uncatalog the deleted dataset has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Using non-VSAM Data Set
Catalog Entries" and refer to the return codes for the catalog processor. The reason code returned is the register 15 return code from the CATALOG macro.
RC=584
Reason=X'rrrrssss'
Meaning: An attempt to locate a dataset prior to its deletion has failed
Action: The specified dataset name may have been deleted or renamed since the last refresh of the dataset mask.
Refresh the dataset mask; if the dataset is still shown retry the request. If the request still fails, contact Compuware
Customer Support and provide the reason code.
I-28
Compuware Workbench Installation Guide
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Retrieving Information by
Dataset Name" and refer to the return codes for LOCATE / CAMLST NAME. The reason code values rrrr and ssss are the return and reason codes from the LOCATE macro, respectively.
RC=588
Reason=X'rrrrrrrr'
Meaning: During an attempt to allocate a new dataset, one of the attributes assigned to the dataset was determined to be invalid or out of range.
Action: Normally, this error should not occur because these attributes are validated by Xpediter/Eclipse prior to being sent to the mainframe for the actual allocation. In the event that the error does occur however, examine the possible reason codes below for one of the following values to determine the invalid attribute. Correct the attribute and retry the request.
00000001 - Primary space value missing or invalid
00000002 - Secondary space value is invalid
00000003 - Number of directory blocks is invalid
00000004 - Expiration date is invalid
00000005 - The block size value is invalid
00000006 - The logical record length value is invalid
00000007 - The record format value is invalid
00000008 - An allocation type of CYLS or TRKS or BLKS not specified
Reference: None.
RC=592
Reason=X'eeeeiiii'
Meaning: During a request to allocate a new dataset, the allocation request has failed.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=596
Reason=X'00000000'
Meaning: During a request to compress a partitioned dataset, the requesting user's security level could not be set for the task so that the task could access the dataset.
Action: Probable internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=600
Reason=X'eeeeiiii'
Meaning: During a request to edit a dataset, the allocation request has failed.
Action: This is a dynamic allocation failure. This error can occur if Xpediter/Eclipse cannot gain exclusive control of the dataset (DISP=OLD). If this is the cause, the reason code will be X'020Ciiii' or X'0210iiii'. For all other causes, look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=604
Reason=X'rrrrrrrr'
Meaning: An attempt to enqueue on a dataset or member for the purpose of editing has failed.
Action: The dataset or member is probably in use by the same or a different user. Check the reason code below to determine possible causes. If the code is not listed, this is a probable environmental error and should be resolved by
Compuware Workbench Messages and Codes
I-29
your system programming personnel. The dataset or member is probably enqueued by another job elsewhere in the system.
00000004 -Exclusive control of the dataset or member could not be obtained
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the ENQ macro and its list of return codes. The reason code rrrrrrrr is the ENQ return code.
RC=608
Reason=X'rrrrrrrr'
Meaning: An attempt to open a dataset for the purpose of editing has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=609
Reason=X'rrrrrrrr'
Meaning: During the retrieval of information about a dataset, an OBTAIN macro failed when trying to locate the format-1 DSCB.
Action: In the unlikely event this error occurs, check the reason code for one of the following:
00000004 - The volume where the dataset resides is not mounted
00000008 - The dataset could not be found on the volume's VTOC
0000000C - I/O error reading the format-1 DSCB
00000010 - Invalid work area pointer. This is an internal error, contact Compuware Customer Support
00000014 - The F1 DSCB address specified is not within the boundaries of the VTOC. Contact Compuware
Technical Support.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 1 subsection "Accessing the VTOC with
DASDM Macros" and refer to the return codes for OBTAIN / CAMLST SEEK. The reason code returned is the register 15 return code from the OBTAIN macro.
RC=610
Reason=X'rrrrrrrr'
Meaning: During the retrieval of information about the VTOC on a volume, an OBTAIN macro failed when trying to locate the format-4 DSCB.
Action: In the unlikely event this error occurs, check the reason code for one of the following:
00000004 - The volume where the dataset resides is not mounted
00000008 - The F4 DSCB could not be found on the volume's VTOC
0000000C - I/O error reading the format-4 DSCB
00000010 - Invalid work area pointer. This is an internal error, contact Compuware Customer Support
00000014 - The F4 DSCB address specified is not within the boundaries of the VTOC. Contact Compuware
Customer Support.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 1 subsection "Accessing the VTOC with
DASDM Macros" and refer to the return codes for OBTAIN / CAMLST SEEK. The reason code returned is the register 15 return code from the OBTAIN macro.
RC=611
Reason=X'rrrrssss'
Meaning: During the retrieval of information about a dataset, a DEVTYPE macro failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to the chapter on "Using System Macro
Instructions", subsection "Obtaining I/O Device Characteristics" and refer to the return codes for DEVTYPE. The reason code values rrrr and ssss are the return and reason codes from the DEVTYPE macro, respectively.
I-30
Compuware Workbench Installation Guide
RC=612
Reason=X'rrrrssss'
Meaning: When attempting to browse or edit a partitioned dataset member, a failure occurred trying to locate the member's directory information.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the BLDL macro and its list of return codes. The reason code values rrrr and ssss are the return and reason codes from the BLDL macro, respectively.
RC=613
Reason=X'eeeeiiii'
Meaning: During a request to save a dataset's contents, the allocation request has failed for a temporary dataset.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=616
Reason=X'rrrrssss'
Meaning: When attempting to browse or edit a partitioned dataset member, a failure occurred trying to locate the member's directory information.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the FIND macro and its list of return codes. The reason code values rrrr and ssss are the return and reason codes from the FIND macro, respectively.
RC=620
Reason=X'rrrrrrrr'
Meaning: When attempting to read a dataset or member during a browse or edit request, the read has failed.
Action: Probable I/O or environmental error. Investigate the HCI job log for unusual error messages and/or abend codes, such as S 001-xx. This can be a difficult error to diagnose. The reason code is the first four bytes of the DECB after a BSAM/BPAM READ/CHECK macro has completed. This return code will be issued whenever the post code within the DECB (the first byte of the reason code) is not equal to X'7F'. The X'7F' value is considered a successful read and any other value is an error condition. If the error cannot be determined, contact Compuware Customer
Support for assistance and provide the reason code as well as any other requested documentation related to the problem.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408, and z/OS DFSMS Using Data Sets SC26-7410.
Refer to the READ and CHECK macros and the processing of sequential and partitioned datasets. The reason code value is the first 4 bytes of the DECB after the CHECK macro completes.
RC=624
Reason=X'rrrrrrrr'
Meaning: When attempting to close an Xpediter/Eclipse edit session or save a dataset or member within an edit session, an error occurred because the request from Xpediter/Eclipse could not be matched up with datasets or members considered to be in edit mode on the mainframe.
Action: Probable internal error. Contact Compuware Customer Support for assistance and provide the return and reason code as well as any other requested documentation related to the problem.
Reference: None.
RC=632
Reason=X'00000000'
Meaning: A Save As… request was issued but no new member name was specified.
Action: Probable user error. A member name is required by a Save As… request.
Reference: None.
Compuware Workbench Messages and Codes
I-31
RC=636
Reason=X'rrrrrrrr'
Meaning: During a Save or Save As… request, a parsing error occurred while processing the inbound datastream to be written to the dataset.
Action: Some of the data may or may not be written to the dataset. This is an internal error. Contact Compuware
Customer Support for assistance and provide the reason code.
Reference: None.
RC=640
Reason=X'rrrrrrrr'
Meaning: When attempting to write to a dataset or member during a Save or Save As… request, the write operation has failed.
Action: Probable I/O or environmental error. Investigate the HCI job log for unusual error messages and/or abend codes, such as S 001-xx. This can be a difficult error to diagnose. The reason code is the first four bytes of the DECB after a BSAM/BPAM WRITE/CHECK macro has completed. This return code will be issued whenever the post code within the DECB (the first byte of the reason code) is not equal to X'7F'. The X'7F' value is considered a successful write and any other value is an error condition. If the error cannot be determined, contact Compuware Customer
Support for assistance and provide the reason code as well as any other requested documentation related to the problem.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408, and z/OS DFSMS Using Data Sets SC26-7410.
Refer to the WRITE and CHECK macros and the processing of sequential and partitioned datasets. The reason code value is the first 4 bytes of the DECB after the CHECK macro completes.
RC=644
Reason=X'rrrrssss'
Meaning: During a Save or Save As… request, an attempt to replace a member of a partitioned dataset as failed.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the STOW macro (R form) and its list of return codes. The reason code rrrr is the STOW return code and ssss is the
STOW reason code.
00080000 - The member to be replaced did not exist, member was added
000C0000 - No space exists in the partitioned dataset directory.
001C0000 - Cannot replace a member of a PDSE program library
RC=648
Reason=X'rrrrssss'
Meaning: During a Save or Save As… request, an attempt to add a member of a partitioned dataset as failed.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the STOW macro (A form) and its list of return codes. The reason code rrrr is the STOW return code and ssss is the
STOW reason code.
00040000 - The member name to be added already exists
000C0000 - No space exists in the partitioned dataset directory.
001C0000 - Cannot add a member to a PDSE program library
RC=652
Reason=X'rrrrssss'
Meaning: During a Save or Save As… request, an attempt to add a member of a partitioned dataset was denied because the requesting user does not have update authority for the dataset.
I-32
Compuware Workbench Installation Guide
Action: Dataset access has been denied by the system security product. Contact your installation's security personnel.
The reason code is the return code from the System Authorization Facility (SAF). The rrrr value is the SAF return code, and the ssss value is the SAF reason code.
Reference: None
RC=656
Reason=X'rrrrrrrr'
Meaning: During a Save or Save As… request, an attempt to obtain a storage area to hold the inbound user data to be written to the dataset has failed.
Action: Insufficient storage exists in the HCI address space. Have your system programmer increase the HCI region size, or retry the request when fewer Xpediter/Eclipse users are connected to the mainframe.
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the GETMAIN RC macro and its list of return codes. The reason code rrrrrrrr is the GETMAIN return code.
RC=660
Reason=X'rrrrrrrr'
Meaning: During a request to move or copy data, certain attributes of the source and destination datasets are validated. This error occurs when a validation check is detected.
Action: Normally, this error condition should be handled by a dialog within Xpediter/Eclipse. However, in the event that this return code occurs, examine the reason code values below to determine the cause, and correct the condition detected is possible and retry the request.
Reason Code Meaning
00000001 - The source and destination datasets are the same dataset, which is invalid for sequential datasets.
00000002 - The source dataset has an unsupported DSORG value. Only PS and PO type datasets are supported.
00000003 - The source dataset specified is not a partitioned dataset, but a member name was specified on the request.
00000004 - No member name was specified (implying a sequential dataset) but the source dataset was not sequential.
00000005 - The destination dataset has an unsupported DSORG value. Only PS and PO type datasets are supported.
00000006 - The destination dataset specified is not a partitioned dataset, but a member name was specified on the request.
00000007 - No member name was specified (implying a sequential dataset) but the destination dataset was not sequential.
00000008 - The source dataset's LRECL value is less than the LRECL value of the destination dataset. Therefore, if the user elects to proceed, the records will be copied and padded with blanks on the right in the destination dataset.
00000009 - The source dataset's LRECL value is greater than the LRECL value of the destination dataset. Therefore, if the user elects to proceed, the records will be copied and truncated to the length of the destination dataset.
0000000A - Cannot copy a sequential or PDS type dataset into a VSAM dataset.
0000000B - Cannot copy a VSAM dataset into a non-VSAM dataset.
0000000C - The source dataset is a VSAM dataset but is an unsupported type. Only KSDS, RRDS, ESDS, and
LINEAR datasets are supported. Catalogs are not supported.
0000000D - The destination dataset is a VSAM dataset but is an unsupported type. Only KSDS, RRDS, ESDS, and
LINEAR datasets are supported. Catalogs are not supported.
0000000E - The source and destination VSAM datasets are not the same VSAM type.
Reference: None
RC=664
Reason=X'eeeeiiii'
Meaning: During a request to move or copy a dataset, the allocation request has failed.
Compuware Workbench Messages and Codes
I-33
Action: This is a dynamic allocation failure. The source or the destination dataset could not be allocated. This error can occur if Xpediter/Eclipse cannot gain exclusive control of the destination dataset (DISP=OLD). If this is the cause, the reason code will be X'020Ciiii' or X'0210iiii'. For all other causes, look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=666
Reason=X'00000002'
Meaning: The connection to HCI has been broken and the TP has ended. This can occur due to line errors or poor wireless connections. It can also occur if Compuware Workbench is terminated without exiting normally (for example, powering off a workstation while Compuware Workbench is active).
Action: The connection was terminated. Reinitiate the connection. The issuance of this return code is not necessarily abnormal and may be ignored.
Reference: None.
RC=668
Reason=X'rrrrrrrr'
Meaning: During a move or copy request, an attempt to open the source dataset has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=669
Reason=X'rrrrssss'
Meaning: During an attempt to open the VSAM source dataset (FROM dataset) in a copy operation, the OPEN macro has failed.
Action: The most likely cause is the source dataset is empty; check the return code to see if it matches the return code described below. If it does, this dataset cannot be copied since it contains no records. For other return codes, this is a probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
OPEN macro and its list of return codes in Chapter 3 which describes both the OPEN return codes and the ACBERFLG codes. The reason code rrrr is the OPEN return code, and the ssss value is the value returned in ACBERFLG. One commonly seen reason code:
000800A0 - The source dataset is empty (contains no records to copy)
RC=670
Reason=X'00xxyyzz'
Meaning: During an attempt to determine the type of the VSAM source dataset (FROM dataset) in a copy operation, the type and its attributes were not identified.
Action: Ensure the type of destination VSAM dataset is one of KSDS, RRDS, ESDS, or LINEAR. Any other type is not supported. If the VSAM type is one of the four supported types and this error occurs, contact Compuware Customer
Support and provide the reason code.
Reference: None.
RC=672
Reason=X'rrrrrrrr'
Meaning: During a move or copy request, an attempt to open the destination dataset has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=673
Reason=X'rrrrssss'
I-34
Compuware Workbench Installation Guide
Meaning: During an attempt to open the VSAM destination dataset (TO dataset) in a copy operation, the OPEN macro has failed.
Action: The most likely cause is the destination dataset is not reusable; check the return code to see if it matches the return code described below. If it does, this dataset cannot be the target of a copy because it is not reusable. For other return codes, this is a probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
OPEN macro and its list of return codes in Chapter 3 which describes both the OPEN return codes and the ACBERFLG codes. The reason code rrrr is the OPEN return code, and the ssss value is the value returned in ACBERFLG. One commonly seen reason code:
000800E8 - The destination dataset is not empty and does not have the REUSE attribute.
RC=674
Reason=X'00xxyyzz'
Meaning: During an attempt to determine the type of the VSAM destination dataset (TO dataset) in a copy operation, the type and its attributes were not identified.
Action: Ensure the type of destination VSAM dataset is one of KSDS, RRDS, ESDS, or LINEAR. Any other type is not supported. If the VSAM type is one of the four supported types and this error occurs, contact Compuware Customer
Support and provide the reason code.
Reference: None.
RC=676
Reason=X'rrrrrrrr'
Meaning: An attempt to enqueue on the destination dataset or member for the purpose of moving or copying that member has failed.
Action: The dataset or member is probably in use by the same or a different user. Check the reason code below to determine possible causes. If the code is not listed, this is a probable environmental error and should be resolved by your system programming personnel. The dataset member is probably enqueued by another job elsewhere in the system.
00000004 -Exclusive control of the member could not be obtained
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the ENQ macro and its list of return codes. The reason code rrrrrrrr is the ENQ return code.
RC=680
Reason=X'rrrrrrrr'
Meaning: When attempting to read a dataset or member during a move or copy request, the read has failed.
Action: Probable I/O or environmental error. Investigate the HCI job log for unusual error messages and/or abend codes, such as S 001-xx. This can be a difficult error to diagnose. The reason code is the first four bytes of the DECB after a BSAM/BPAM READ/CHECK macro has completed. This return code will be issued whenever the post code within the DECB (the first byte of the reason code) is not equal to X'7F'. The X'7F' value is considered a successful read and any other value is an error condition. If the error cannot be determined, contact Compuware Customer
Support for assistance and provide the reason code as well as any other requested documentation related to the problem.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408, and z/OS DFSMS Using Data Sets SC26-7410.
Refer to the READ and CHECK macros and the processing of sequential and partitioned datasets. The reason code value is the first 4 bytes of the DECB after the CHECK macro completes.
RC=681
Reason=X'xxxxyyyy'
Meaning: During an attempt to read a record from the VSAM source dataset (FROM dataset) in a copy operation, the
GET macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
RPL based list of return codes in Chapter 3 which describes both the GET/PUT return codes and reason codes. The reason code xxxx is the GET return code, and the yyyy value is the value returned in RPLERRCD.
Compuware Workbench Messages and Codes
I-35
RC=684
Reason=X'rrrrrrrr'
Meaning: When attempting to write to a dataset or member during a move or copy request, the write operation has failed.
Action: Probable I/O or environmental error. Investigate the HCI job log for unusual error messages and/or abend codes, such as S 001-xx. This can be a difficult error to diagnose. The reason code is the first four bytes of the DECB after a BSAM/BPAM WRITE/CHECK macro has completed. This return code will be issued whenever the post code within the DECB (the first byte of the reason code) is not equal to X'7F'. The X'7F' value is considered a successful write and any other value is an error condition. If the error cannot be determined, contact Compuware Customer
Support for assistance and provide the reason code as well as any other requested documentation related to the problem.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408, and z/OS DFSMS Using Data Sets SC26-7410.
Refer to the WRITE and CHECK macros and the processing of sequential and partitioned datasets. The reason code value is the first 4 bytes of the DECB after the CHECK macro completes.
RC=685
Reason=X'xxxxyyyy'
Meaning: During an attempt to write a record to the VSAM destination dataset (TO dataset) in a copy operation, the
PUT macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
RPL based list of return codes in Chapter 3 which describes both the GET/PUT return codes and reason codes. The reason code xxxx is the PUT return code, and the yyyy value is the value returned in RPLERRCD.
RC=688
Reason=X'rrrrssss'
Meaning: When attempting to move or copy a partitioned dataset member, a failure occurred trying to locate the member's directory information in the source dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the BLDL macro and its list of return codes. The reason code values rrrr and ssss are the return and reason codes from the BLDL macro, respectively.
RC=692
Reason=X'rrrrssss'
Meaning: When attempting to move or copy a partitioned dataset member, a failure occurred trying to locate the member's directory information in the source dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the FIND macro and its list of return codes. The reason code values rrrr and ssss are the return and reason codes from the FIND macro, respectively.
RC=696
Reason=X'rrrrssss'
Meaning: During a move or copy request, an attempt to replace a member within the destination dataset as failed.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the STOW macro (R form) and its list of return codes. The reason code rrrr is the STOW return code and ssss is the
STOW reason code.
00080000 - The member to be replaced did not exist, member was added
000C0000 - No space exists in the partitioned dataset directory.
001C0000 - Cannot replace a member of a PDSE program library
I-36
Compuware Workbench Installation Guide
RC=700
Reason=X'rrrrssss'
Meaning: During a move or copy request, an attempt to add a member to the destination dataset as failed.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the STOW macro (A form) and its list of return codes. The reason code rrrr is the STOW return code and ssss is the
STOW reason code.
00040000 - The member name to be added already exists
000C0000 - No space exists in the partitioned dataset directory.
001C0000 - Cannot add a member to a PDSE program library
RC=704
Reason=X'rrrrssss'
Meaning: When attempting to move or copy a partitioned dataset member, a failure occurred trying to locate the member's directory information in the destination dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the FIND macro and its list of return codes. The reason code values rrrr and ssss are the return and reason codes from the FIND macro, respectively.
RC=708
Reason=X'00000000'
Meaning: During a move request, an undesirable outcome occurred in the destination dataset (for example, member was not replaced). Therefore, this return code is used to indicate to Xpediter/Eclipse that it should not delete the source dataset or member since the copy portion of the move operation did not fully complete.
Action: None. This is an internal notification to Xpediter/Eclipse to not delete the source dataset or member on a move request.
Reference: None.
RC=712
Reason=X'00000004'
Meaning: During a move or copy request, a member was not replaced.
Action: The member was not replaced because the Replace option was not specified. This is not an error in copying or moving the member, rather it is only an indication that the request did not succeed because the member could not be replaced.
Reference: None.
RC=720
Reason=X'rrrrrrrr'
Meaning: A dataset has been renamed, but a follow-on request to uncatalog the original name has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Using non-VSAM Data Set
Catalog Entries" and refer to the return codes for the catalog processor. The reason code returned is the register 15 return code from the CATALOG macro.
RC=724
Reason=X'rrrrrrrr'
Meaning: A dataset has been renamed, but a follow-on request to catalog the new name has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Compuware Workbench Messages and Codes
I-37
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Using non-VSAM Data Set
Catalog Entries" and refer to the return codes for the catalog processor. The reason code returned is the register 15 return code from the CATALOG macro.
RC=728
Reason=X'rrrrssss'
Meaning: An attempt to locate a dataset prior to uncataloging it has failed
Action: The specified dataset name may have been deleted or renamed since the last refresh of the dataset mask.
Refresh the dataset mask; if the dataset is still shown retry the request. If the request still fails, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Retrieving Information by
Dataset Name" and refer to the return codes for LOCATE / CAMLST NAME. The reason code values rrrr and ssss are the return and reason codes from the LOCATE macro, respectively.
RC=732
Reason=X'00080003'
Meaning: An attempt to rename a dataset has failed. The new dataset name already exists.
Action: The rename request failed because the new name being chosen already exists. Choose a different name and retry the request. This return code may also present reason code X'00000000'; the meaning is identical.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 2 subsection "RENAME and CAMLST
Macro Specification" and refer to the return codes for the RENAME macro. The reason code values rrrr and ssss are the return and reason codes from the RENAME macro, respectively.
RC=740
Reason=X'rrrrssss'
Meaning: An attempt to locate a dataset has failed (dataset validation request).
Action: Probable user error. The specified dataset name may have been incorrectly typed or the dataset simply does not exist. Verify the specified dataname and if correct, contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 3 subsection "Retrieving Information by
Dataset Name" and refer to the return codes for LOCATE / CAMLST NAME. The reason code values rrrr and ssss are the return and reason codes from the LOCATE macro, respectively.
RC=744
Reason=X'00000000'
Meaning: No IMS MPP transaction codes have been defined.
Action: Probable installation error. When Xpediter/TSO support for Xpediter/Eclipse is installed, the installer runs a utility program called XTCSPFIN, which initializes the Compuware Shared Profile dataset with the IMS MPP transaction codes. This step either has not been performed, or no IMS MPP transaction codes were defined when the utility program was executed. Ask the installer to specify the appropriate codes and rerun the utility. If the error persists and transaction codes have been specified as indicated in the documentation reference below, contact Compuware
Customer Support for assistance.
Reference: Xpediter/TSO Installation Guide
RC=756
Reason=X'rrrrrrrr'
Meaning: A delete request has failed for a migrated dataset.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: IBM’s z/OS DFSMShsm Managing Your Own Data SC35-0420 (see Chapter 22, "Using DFSMShsm User
Macros", in section "Register Usage for Return Codes"). The reason code rrrrrrrr is the ARCHDEL macro return code.
00000002 - Dataset name specified did not exist
00000027 - Insufficient access authority
00000064 - DFSMS is not active on the system
I-38
Compuware Workbench Installation Guide
00000192 - Dataset name not found
00000193 - Dataset name was * or blank
00000806 - Error linking to DFSMS service
00000zzz -Any other value: HDELETE function failed
RC=760
Reason=X'00000000'
Meaning: The member name specified does not exist. This member was being specified in the Xpediter/Eclipse batch debugging launch dialog.
Action: Probable user error. Check that the member name specified does exist in the specified dataset, or choose another existing member name.
Reference: None.
RC=764
Reason=X'00000000'
Meaning: An attempt to browse or edit a partitioned dataset has failed because no member name was specified.
Action: Probable user error. If the dataset type is partitioned, a member name is required.
Reference: None.
RC=768
Reason=X'00000000'
Meaning: During an attempt to cancel a job or its output, the security level of the user could not be validated. The attempt is aborted.
Action: Verify that the userid that was signed on to the session is defined within the security package on your system.
If the error persists, contact Compuware Customer Support for assistance.
Reference: None.
RC=769
Reason=X'00000000'
Meaning: During an attempt to issue a console operator command, the command syntax was found to be invalid.
The attempt is aborted.
Action: Verify that the command issued is using the command's proper syntax.
Reference: None.
RC=772
Reason=X’xxxxxxxx’
Meaning: The user has insufficient authority to purge or cancel the specified job or to issue a console operator command.
Action: If the reason code is 00000000, add the dataset containing the TP load module (CXTPMAIN) to the APF dataset list. For all other return codes, the user cannot cancel the job or purge the output due to insufficient authority as determined by the system security software. The reason code consists of the following security information:
00000000 – TP is not APF-authorized (not common; should not occur)
FFFFFFFF – BY-USERID configuration setting has determined that the connected user is not the owner of the selected output.
ssrrcccc – The return codes from a RACROUTE AUTH macro, where:
ss – is the SAF RC
rr – is the RACF RC
cccc – is the reason
Typically, insufficient access authority to purge output would result in a reason code value of 08080000.
Reference: None.
Compuware Workbench Messages and Codes
I-39
RC=776
Reason=X'rrrrrrrr'
Meaning: During an attempt to issue a console operator command, the attempt was aborted because the user does not have sufficient authority to issue the command.
Action: Contact your security administrator.
Reference: None.
RC=777
Reason=X'0000000x'
Meaning: The connection with the client workstation has been terminated and the TP has ended. The termination is because either the TP Administrator forcibly terminated the TP, or the TP timed out due to inactivity.
Action: Reinitiate the connection. If TPs are being terminated for inactivity with an undesirable frequency, the inactivity time out value can be controlled by the INACTIVITY statement in the TP Configuration File member.
Reference: The reason code x for this return code is one of these values:
00000000 - TP was terminated by the TP Administrator
00000001 - TP was terminated due to inactivity.
RC=780
Reason=X'00000000'
Meaning: During an attempt to cancel a job or its output, it was determined that the primary subsystem is not JES2 or JES3.
Action: Only JES2 and JES3 subsystems are supported; and one of them must be the primary subsystem. Contact your system installer for assistance.
Reference: None
RC=784
Reason=X'00000000'
Meaning: The TP is not APF-authorized and therefore cannot issue a Start command.
Action: Add the dataset containing the TP load module (CXTPMAIN) to the APF dataset list.
Reference: None.
RC=785
Reason=X'00000000'
Meaning: During a search to locate the HCI, the HCI's jobname could not be found.
Action: Restart the HCI is if is inactive.
Reference: None.
RC=786
Reason=X'rrrrrrrr'
Meaning: A failure occurred attempting to establish a connection with the HCI.
Action: Probable internal error. Contact Compuware Customer Support for assistance.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the ALESERV macro and its list of return codes and reason codes. The reason code rrrrrrrr is the return code from ALESERV.
RC=787
Reason=X'rrrrrrrr'
Meaning: A failure occurred attempting to synchronize communication with HCI.
Action: Probable internal error. Contact Compuware Customer Support for assistance.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the POST macro and its list of return codes and reason codes. The reason code rrrrrrrr is the return code from POST.
I-40
Compuware Workbench Installation Guide
RC=788
Reason=X'00000000'
Meaning: The TP load module name is unknown.
Action: This is an internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=789
Reason=X'00000000'
Meaning: Unable to obtain version check information.
Action: This is an internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=790
Reason=X'00000000'
Meaning: Unable to obtain version check information. A timer has expired while waiting for it to be returned.
Action: This is an internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=791
Reason=X'00000000'
Meaning: A version check was issued inside a started-task, which is improper operation.
Action: This is an internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=792
Reason=X'00000000'
Meaning: The started-task TP procedure name was not specified in the TP Configuration File member.
Action: Specify the STASK statement in the TP Configuration File member with the 8-character procedure name of the
TP started-task procedure.
Reference: See section, “Create and Manage the CSS TP Configuration Member” on page F-1.
RC=796
Reason=X'rrrrrrrr'
Meaning: During an attempt to issue a Start command to run a started-task TP, the attempt was aborted by the system.
Action: Probable internal error. Contact Compuware Customer Support for assistance.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the MCGRE macro and its list of return codes and reason codes. The reason code rrrrrrrr is the return code from MGCRE.
RC=800
Reason=X'rrrrrrrr'
Meaning: During an attempt to run a started-task TP, the attempt failed when the HCI conversation could not be passed to the started-task TP.
Action: Probable internal error, CW_PCNV has failed. Contact Compuware Customer Support for assistance and provide the return code and HCI output.
Reference: None.
RC=806
Reason=X'rrrrrrrr'
Meaning: A load failed for a module needed to support a request.
Compuware Workbench Messages and Codes
I-41
Action: Probable installation/configuration error. The reason code is the abend code that would have occurred by the failure of a LOAD macro. The most probable code is 08060004 which means the module could not be found. Verify that the HCI STEPLIB concatenation contains all of the datasets needs to support your request.
Reference: ECC Installation and Customization Guide.
RC=812
Reason=X'rrrrrrrr'
Meaning: During a request to launch a debugging session, an attempt to get the TCP/IP client ID and socket number of this TP conversation has failed. The return code is from CW_GCID.
Action: Probable internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=816
Reason=X'rrrrrrrr'
Meaning: During a request to launch a debugging session, an attempt to pass the socket to the application being debugged (via TCP/IP GIVESOCKET) has failed. The return code is from CW_GSOK.
Action: Probable internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=820
Reason=X'rrrrrrrr'
Meaning: During a request to launch a debugging session, the request timed-out because no connection to the application to be debugged could be established. The return code is from CW_SELC.
Action: Probable user or configuration error. Verify that the application being debugged has started, and that it is executing on the same LPAR as the HCI that you are connected with. If the error persists, contact Compuware
Customer Support for assistance.
Reference: None.
RC=832
Reason=X'rrrrrrrr'
Meaning: While attempting to retrieve a list of members from a PDS or PDSE directory, the dataset specified is not partitioned.
Action: Probable user error. Ensure the dataset specified is partitioned (DSORG=PO).
Reference: None.
RC=836
Reason=X'eeeeiiii'
Meaning: During a request to retrieve JES spool output, the allocation request has failed.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
RC=840
Reason=X'rrrrrrrr'
Meaning: While attempting to retrieve JES spool output, an OPEN macro failed opening the JES spool dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
I-42
Compuware Workbench Installation Guide
RC
0
880
880
880
880
880
880
880
880
880
880
RC=844
Reason=X'rrrrrrrr'
Meaning: While attempting to retrieve JES spool output, an GET macro failed opening the JES spool dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
GET macro and its list of return codes. The reason code rrrrrrrr is the value returned in RPLFDBWD.
RC=848
Reason=X'rrrrrrrr'
Meaning: Host Explorer could not validate that a validly licensed Compuware mainframe product exists on the LPAR.
Action: At least one Compuware product must have a valid license certificate on this LPAR for Host Explorer to function. If you believe this return code is issued in error, contact Compuware Customer Support and provide the reason code.
Reference: None.
RC=852
Reason=X'rrrrrrrr'
Meaning: A licensing service error was received while trying to validate a Compuware license.
Action: At least one Compuware product must have a valid license certificate on this LPAR for Host Explorer to function. If you believe this return code is issued in error, contact Compuware Customer Support and provide the reason code.
Reference: None.
RC=880
Reason=X'rrrrrrrr'
Meaning: During the allocation of a VSAM dataset, invalid parameters were specified, or critical parameters were omitted. The dataset could not be allocated.
Action: Locate the reason code in the table below to identify the cause of the error. Correct the parameter specification or supply the identified missing parameter and retry the allocation request.
Reference: None
RC and Reason codes for VSAM allocation
C/D/I column indicates error applies to Cluster, Data, or Index component.
C/D/I
8
9
A
6
7
2
3
4
5
Reason
0
1 C
C
C
C
C
C
D
C/D
D
Description
Request successfully processed
<cluster> tag not specified, required.
Cluster type is not a valid value
Expiration date specification is not numeric
Expiration date year is not in the range 1900-2099 inclusive
Expiration date month is not in the range 01-12 inclusive
Expiration date day is not valid for the specified month
--unassigned
Allocation units type specification is not a valid value
No allocation units were specified for cluster or data
Primary is not numeric
Compuware Workbench Messages and Codes
I-43
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
RC
880
880
880
880
880
880
1F
20
21
22
1B
1C
1D
1E
23
24
25
26
27
17
18
19
1A
13
14
15
16
F
10
11
12
Reason
B
C
D
E
D
D
D
D
D
D
D
D
I
D
I
D
I
I
I
D
D
D
D
D
C/D
D
D
C/D
D
I
C/D/I
D
D
28
29
D
D
Description
Primary is zero
Secondary is not numeric
Allocation units type specification is not a valid value
--unassigned
Primary is not numeric
Primary is zero
Secondary is not numeric
Bufferspace is not numeric
CI size is not numeric
CI size is not numeric
CI size is larger than 32768
CI size is larger than 32768
Freespace CI is not numeric
Freespace CI is larger than 100
Freespace CA is not numeric
Freespace CA is larger than 100
Record size maximum is not numeric
Record size specification is invalid for LINEAR clusters
Record size maximum is not in the range 1-32716 inclusive for non-spanned records
Record size maximum is zero
Record size average is not numeric
Record size average is zero
Record size average is larger than the record size maximum
Key length and/or key offset position invalid for ESDS/LINEAR cluster types
Key offset position is not numeric
Key offset position is greater than the maximum record size less the key length
Key length is not numeric
Key length is not is the range 1-255 inclusive
Both record size average and record size maximum must be specified together. One of them was omitted.
Both key length and key offset position must be specified together. One of them was omitted.
Shareoption 1 is not in the range 1-4 inclusive
I-44
Compuware Workbench Installation Guide
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
880
RC
880
880
880
880
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
43
44
45
46
47
48
3F
40
41
42
3B
3C
3D
3E
37
38
39
3A
33
34
35
36
2E
2F
30
31
32
Reason
2A
2B
2C
2D
C/D/I
I
D
I
C/D
C
C
C
C
C/D
C
C
C
Description
Shareoption 2 is not in the range 3-4 inclusive
Shareoption 1 is not in the range 1-4 inclusive
Shareoption 2 is not in the range 3-4 inclusive
No primary space value was specified for either cluster or data; one of them must be specified.
No cluster name was specified
--unassigned
Allocation units type specification is not a valid value
--unassigned
Primary is not numeric
Primary is zero
Secondary is not numeric
Bufferspace is not numeric
CI size is not numeric
CI size is larger than 32768
Freespace CI is not numeric
Freespace CI is larger than 100
Freespace CA is not numeric
Freespace CA is larger than 100
Record size maximum is not numeric
Record size specification is invalid for LINEAR clusters
Record size maximum is not in the range 1-32716 inclusive for non-spanned records
Record size maximum is zero
Record size average is not numeric
Record size average is zero
--unassigned
Key length and/or key offset position invalid for ESDS/LINEAR cluster types
Key offset position is not numeric
Key length is greater than the maximum record size
Key length is not numeric
Key length is not is the range 1-255 inclusive
Both record size average and record size maximum must be specified together. One of them was omitted.
Compuware Workbench Messages and Codes
I-45
RC
880
880
880
880
Reason
49
4A
4B
4C
C/D/I
C
C
C
C/D/I
Description
Both key length and key offset position must be specified together. One of them was omitted.
Shareoption 1 is not in the range 1-4 inclusive
Shareoption 2 is not in the range 3-4 inclusive
A space allocation was specified at the cluster level, but another space allocation was detected at the data and/or index levels. Cluster level space allocation is mutually exclusive with data and index allocations.
RC=881
Reason=X'eeeeiiii'
Meaning: During a request to allocate a VSAM cluster, an attempt to allocate a temporary dataset to hold IDCAMS control information has failed during dynamic allocation.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=882
Reason=X'eeeeiiii'
Meaning: During a request to allocate a VSAM cluster, an attempt to allocate a temporary dataset to hold IDCAMS
SYSOUT information has failed during dynamic allocation.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=883
Reason=X'rrrrrrrr'
Meaning: During a request to allocate a VSAM cluster, the IDCAMS utility was called to allocate the new dataset.
IDCAMS has failed during the creation request.
Action: The workstation user is presented an opportunity to view the output from IDCAMS which should indicate the reason for the error. Usually, this type of error will occur when one or more of the parameters needed to create the dataset is missing or invalid. This output can also be viewed with an appropriate output viewing utility on the mainframe; the output is located as one of the DD names associated with the HCI that the workstation user is connected.
Reference: z/OS DFSMS Access Method Services, SC26-7394. Refer to the chapter associated with DEFINE CLUSTER along with the IDCAMS output. The reason code rrrrrrrr is the return code received from IDCAMS.
RC=884
Reason=X'rrrrrrrr'
Meaning: During a request to allocate a VSAM cluster, an attempt to open a temporary dataset used to contain control information has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=888
Reason=X'00000000'
Meaning: The user has requested an abort or cessation of the current activity, for example: aborting a long running search in progress, or aborting the retrieval of a large JES output file.
Action: None.
I-46
Compuware Workbench Installation Guide
Reference: None.
RC=901
Reason=X'00000000'
Meaning: z/OS Unix System Services is not active in this LPAR.
Action: z/OS Unix System Services must be active in order to operate with zFS and HFS files. Start z/OS Unix System
Services and recycle the HCI in order to recognize that z/OS Unix is now available
Reference: None.
RC=902
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to determine the current user's z/OS Unix working directory, the getwd( ) function has failed.
Action: Service getwd(BPX1GWD) has failed. Using the reason code value as the BPX1GWD return code, look up the return code in the manuals referenced below to determine the cause. The user may not have access authority to the directory or the file system may not be properly mounted for example. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the getwd(BPX1GWD) service. The reason code xxxxxxx is the BPX1GWD return code, and the extended reason code yyyyyyy is the BPX1GWD reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=903
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to change to a new directory as specified by the user, the chdir( ) function has failed.
Action: Service chdir(BPX1CHD) has failed. Using the reason code value as the BPX1CHD return code, look up the return code in the manuals referenced below to determine the cause. The user may not have access authority to the directory or the file system may not be properly mounted for example. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the chdir(BPX1CHD) service. The reason code xxxxxxx is the BPX1CHD return code, and the extended reason code yyyyyyy is the BPX1CHD reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=904
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to open the new directory path as specified by the user the opendir( ) function has failed.
Action: Service opendir(BPX1OPD) has failed. Using the reason code value as the BPX1OPD return code, look up the return code in the manuals referenced below to determine the cause. The user may not have access authority to the directory or the file system may not be properly mounted for example. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the opendir(BPX1OPD) service. The reason code xxxxxxx is the BPX1OPD return code, and the extended reason code yyyyyyy is the BPX1OPD reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
Compuware Workbench Messages and Codes
I-47
RC=905
Reason=X'xxxxxxxx'
Meaning: During an attempt to obtain the contents of a directory, a failure occurred trying to obtain 64-bit storage.
Action: The IARV64 macro has failed. Ensure that the system is enabled for 64-bit storage and that the system
MEMLIMIT value is not zero.
Reference: z/OS MVS Programming: Assembler Services Reference SA22-7607. Refer to the IARV64 macro. The reason code xxxxxxx is the return code of the IARV64 macro.
RC=906
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to read the directory path as specified by the user the readdir( ) function has failed.
Action: Service readdir(BPX1RDD) has failed. Using the reason code value as the BPX1RDD return code, look up the return code in the manuals referenced below to determine the cause. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the readdir(BPX1RDD) service. The reason code xxxxxxx is the BPX1RDD return code, and the extended reason code yyyyyyy is the BPX1OPD reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=907
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: Unable to obtain the status and properties for a file or subdirectory. The stat( ) service has failed.
Action: Service stat(BPX1STA) has failed. Using the reason code value as the BPX1STA return code, look up the return code in the manuals referenced below to determine the cause. If the error persists, contact Compuware Customer
Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the stat(BPX1STA) service. The reason code xxxxxxx is the BPX1STA return code, and the extended reason code yyyyyyy is the BPX1STA reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=908
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: Unable to close the directory specified by the user. The closedir( ) function has failed.
Action: Service closedir(BPX1CLD) has failed. Using the reason code value as the BPX1CLD return code, look up the return code in the manuals referenced below to determine the cause. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the closedir(BPX1CLD) service. The reason code xxxxxxx is the BPX1CLD return code, and the extended reason code yyyyyyy is the BPX1CLD reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=909
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to change back to the user's original working directory, the chdir( ) function has failed.
I-48
Compuware Workbench Installation Guide
Action: Service chdir(BPX1CHD) has failed. Using the reason code value as the BPX1CHD return code, look up the return code in the manuals referenced below to determine the cause. The user may not have access authority to the directory or the file system may not be properly mounted for example. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the chdir(BPX1CHD) service. The reason code xxxxxxx is the BPX1CHD return code, and the extended reason code yyyyyyy is the BPX1CHD reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=910
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: Unable to obtain the status and properties for the specified file. The stat( ) service has failed prior to an attempt to read the z/OS Unix file.
Action: Service stat(BPX1STA) has failed. Using the reason code value as the BPX1STA return code, look up the return code in the manuals referenced below to determine the cause. If the error persists, contact Compuware Customer
Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the stat(BPX1STA) service. The reason code xxxxxxx is the BPX1STA return code, and the extended reason code yyyyyyy is the BPX1STA reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=911
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to open the specified z/OS Unix file for read access, the open( ) function has failed.
Action: Service open(BPX1OPN) has failed. Using the reason code value as the BPX1OPN return code, look up the return code in the manuals referenced below to determine the cause. The user may not have read access authority to the file or the file system may not be properly mounted for example. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the open(BPX1OPN) service. The reason code xxxxxxx is the BPX1OPN return code, and the extended reason code yyyyyyy is the BPX1OPN reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=912
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to read the contents of a z/OS Unix file, the read( ) function has failed.
Action: Service read(BPX1RED) has failed. Using the reason code value as the BPX1RED return code, look up the return code in the manuals referenced below to determine the cause. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the read(BPX1RED) service. The reason code xxxxxxx is the BPX1RED return code, and the extended reason code yyyyyyy is the BPX1RED reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=913
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Compuware Workbench Messages and Codes
I-49
Meaning: During an attempt to close a z/OS Unix file, the close( ) function has failed.
Action: Service close(BPX1CLO) has failed. Using the reason code value as the BPX1CLO return code, look up the return code in the manuals referenced below to determine the cause. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the close(BPX1CLO) service. The reason code xxxxxxx is the BPX1CLO return code, and the extended reason code yyyyyyy is the BPX1CLO reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=915
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to open the specified z/OS Unix file for writing, the open( ) function has failed.
Action: Service open(BPX1OPN) has failed. Using the reason code value as the BPX1OPN return code, look up the return code in the manuals referenced below to determine the cause. The user may not have write access authority to the file or the file system may not be properly mounted for example. If the error persists, contact Compuware
Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the open(BPX1OPN) service. The reason code xxxxxxx is the BPX1OPN return code, and the extended reason code yyyyyyy is the BPX1OPN reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=916
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to write the contents of a z/OS Unix file, the write( ) function has failed.
Action: Service write(BPX1WRT) has failed. Using the reason code value as the BPX1WRT return code, look up the return code in the manuals referenced below to determine the cause. For example, the user may not have write access to the file. If the error persists, contact Compuware Customer Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the write(BPX1WRT) service. The reason code xxxxxxx is the BPX1WRT return code, and the extended reason code yyyyyyy is the BPX1WRT reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=917
Reason=X'nnnnnnnn'
Extended Reason=X'00000000'
Meaning: During an attempt to write the contents of a z/OS Unix file, the requested amount of data to be written was not completely written out to the file.
Action: Ensure that sufficient space exists for writing the file. The nnnnnnnn value indicates the number of bytes that were actually written. If the error persists, contact Compuware Customer Support for assistance.
Reference: None.
RC=918
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: During an attempt to close a z/OS Unix file, the close( ) function has failed.
Action: Service close(BPX1CLO) has failed. Using the reason code value as the BPX1CLO return code, look up the return code in the manuals referenced below to determine the cause. If the error persists, contact Compuware
Customer Support for assistance.
I-50
Compuware Workbench Installation Guide
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the close(BPX1CLO) service. The reason code xxxxxxx is the BPX1CLO return code, and the extended reason code yyyyyyy is the BPX1CLO reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=919
Reason=X'xxxxxxxx'
Extended Reason=X'yyyyyyyy'
Meaning: Unable to obtain the status and properties for the specified file. The stat( ) service has failed prior to an attempt to read the z/OS Unix file.
Action: Service stat(BPX1STA) has failed. Using the reason code value as the BPX1STA return code, look up the return code in the manuals referenced below to determine the cause. If the error persists, contact Compuware Customer
Support for assistance.
Reference: z/OS Unix System Services Programming: Assembler Callable Services Reference SA22-7803. Chapter 2
Callable Services Descriptions. Refer to the stat(BPX1STA) service. The reason code xxxxxxx is the BPX1STA return code, and the extended reason code yyyyyyy is the BPX1STA reason code.
The return codes from z/OS Unix callable services are documented in z/OS Unix System Services Messages and Codes
SA22-7807. Chapter 2 documents the return codes from the various services.
RC=920
Reason=X'xxxxxxxx'
Extended Reason=X'00000000'
Meaning: During an attempt to read a z/OS Unix file, the TP was unable to obtain exclusive control of the file. The
ENQ macro has failed.
Action: The file is in use by the same or a different user. Check the reason code below to determine possible causes.
If the code is not listed, this is a probable environmental error and should be resolved by your system programming personnel. The file is most likely in use by another job or user elsewhere in the system.
00000004 -Exclusive control of the file could not be obtained
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the ENQ macro and its list of return codes. The reason code xxxxxxxx is the ENQ return code.
RC=921
Reason=X'xxxxxxxx'
Extended Reason=X'00000000'
Meaning: During an attempt to write a z/OS Unix file, the TP was unable to obtain exclusive control of the file. The
ENQ macro has failed.
Action: The file is in use by the same or a different user. Check the reason code below to determine possible causes.
If the code is not listed, this is a probable environmental error and should be resolved by your system programming personnel. The file is most likely in use by another job or user elsewhere in the system.
00000004 -Exclusive control of the file could not be obtained
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the ENQ macro and its list of return codes. The reason code xxxxxxxx is the ENQ return code.
RC=922
Reason=X'rrrrrrrr'
Meaning: When attempting to release exclusive control of a z/OS Unix file, an error occurred because the request from Compuware Workbench could not be matched up with the request that owns the exclusive control lock. No lock key was transmitted.
Action: Probable internal error. Contact Compuware Customer Support for assistance and provide the return and reason code as well as any other requested documentation related to the problem.
Reference: None.
Compuware Workbench Messages and Codes
I-51
RC=923
Reason=X'rrrrrrrr'
Meaning: When attempting to release exclusive control of a z/OS Unix file, an error occurred because the request from Compuware Workbench could not be matched up with the request that owns the exclusive control lock. The lock key value was invalid.
Action: Probable internal error. Contact Compuware Customer Support for assistance and provide the return and reason code as well as any other requested documentation related to the problem.
Reference: None.
RC=924
Reason=X'rrrrrrrr'
Meaning: When attempting to release exclusive control of a z/OS Unix file, an error occurred because the request from Compuware Workbench could not be matched up with the request that owns the exclusive control lock. The specified lock key was valid but belongs to a different user.
Action: Probable internal error. Contact Compuware Customer Support for assistance and provide the return and reason code as well as any other requested documentation related to the problem.
Reference: None.
RC=925
Reason=X'00ssrrxx'
Meaning: Unable to determine the z/OS Unix home directory path name for the user.
Action: The reason codes are the result of the RACROUTE EXTRACT macro. The home directory path information is part of the user profile. This is probably a system security software configuration error. Contact your security administrator for assistance. Additionally, assistance may be required from Compuware Customer Support.
The reason code consists of the following security information:
00ssrrxx - The return codes from a RACROUTE EXTRACT macro, where: ss - is the SAF RC rr - is the RACF RC xx - is the RACF reason
The most common reasons are: ss = 04 : No home path data exists in the security database ss = 08 : signed on user does not have z/OS Unix System Services access (no OMVS segment)
Reference: None.
RC=926
Reason=X'00000000'
Meaning: During an attempt to start the external trace, the external trace was already active.
Action: Stop the external trace and capture the contents prior to starting a new trace.
Reference: None.
RC=927
Reason=X'eeeeiiii'
Meaning: During an attempt to start the external trace, the TP could not allocate the external trace dataset.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=928
Reason=X'rrrrrrrr'
I-52
Compuware Workbench Installation Guide
Meaning: During an attempt to start the external trace, the TP could not open the external trace dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=929
Reason=X'00000000'
Meaning: During an attempt to stop the external trace, the external trace was found to be inactive (not started).
Action: None.
Reference: None.
RC=930
Reason=X'00000000'
Meaning: During an attempt to capture the external trace, the external trace was already active and recording data.
Action: Stop the external trace before initiating a trace capture.
Reference: None.
RC=931
Reason=X'rrrrrrrr'
Meaning: During an attempt to cature the external trace content, the TP could not open the external trace dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=932
Reason=X'00000000'
Meaning: The external trace recording dataset has exhausted all of its available space. Not all of the trace data has been recorded.
Action: If the data is retrieved by a subsequent capture request, only the data that was recorded prior to the out-ofspace condition will be returned.
Reference: None.
RC=933
Reason=X'00000000'
Meaning: During an attempt to start the external trace with space overrides for the external trace dataset, the space values were invalid (non-numeric).
Action: Specify only numeric primary and secondary space values in the external trace start request.
Reference: None.
RC=935
Reason=X'rrrrrrrr'
Meaning: During an attempt to obtain member data from a list of concatenated datasets, a specification error occurred.
Action: Review the reason codes below for the cause of the error, and change the specification to avoid future recurrences of the error condition.
The reason code rrrrrrrr is defined as follows:
00000002 - More than 255 datasets specified in the concatenation.
00000003 - No datasets were specified.
00000004 - No members were specified.
00000005 - Member list not in alphameric collating sequence.
Compuware Workbench Messages and Codes
I-53
00000006 - More than 32767 members specified.
Reference: None.
RC=936
Reason=X'rrrrrrrr'
Meaning: During an attempt to obtain member data from a list of concatenated datasets, more or more of the specified datasets did not meet requirements needed to complete the concatenation.
Action: Review the reason codes below for the cause of the error, and change the specification to avoid future recurrences of the error condition.
The reason code rrrrrrrr is defined as follows:
00000001 - Dataset was not partitioned (not PDS or PDSE).
00000002 - Dataset was not found.
00000003 - Dataset is migrated.
00000004 - The requesting user does not have READ access authority to the dataset.
Reference: None.
RC=937
Reason=X'rrrrrrrr'
Meaning: During the retrieval of information about a dataset, an OBTAIN macro failed when trying to locate the format-1 DSCB.
Action: In the unlikely event this error occurs, check the reason code for one of the following:
00000004 - The volume where the dataset resides is not mounted
00000008 - The dataset could not be found on the volume's VTOC
0000000C - I/O error reading the format-1 DSCB
00000010 - Invalid work area pointer. This is an internal error, contact Compuware Customer Support
Reference: z/OS DFSMSdfp Advanced Services SC26-7400. Refer to Chapter 1 subsection "Accessing the VTOC with
DASDM Macros" and refer to the return codes for OBTAIN / CAMLST SEARCH. The reason code returned is the register
15 return code from the OBTAIN macro.
RC=938
Reason=X'eeeeiiii'
Meaning: During an attempt to allocate datasets for a concatenation, one of the datasets could not be allocated.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=939
Reason=X'eeeeiiii'
Meaning: During an attempt to concatenate a list of previously allocated datasets, the dynamic concatenation request has failed.
Action: This is a dynamic concatenation. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=940
Reason=X'rrrrrrrr'
Meaning: During an attempt to open a dynamic concatenation, the OPEN macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
I-54
Compuware Workbench Installation Guide
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=941
Reason=X'rrrrssss'
Meaning: When attempting to obtain member data from a concatenation, a failure occurred trying to locate the member's directory information.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the BLDL macro and its list of return codes. The reason code values rrrr and ssss are the return and reason codes from the BLDL macro, respectively.
RC=942
Reason=X'00000000'
Meaning: When attempting to obtain member data from a concatenation, one of the members was not found in the concatenation.
Action: None. Processing continues with the remaining specified members.
Reference: None.
RC=945
Reason=X'xxxxxxxx'
Meaning: When attempting to cease the activity of a long running TP task (for example during a file search), an error was encountered with the request.
Action: Look up the reason code in the list below for the cause. TP tasks are dynamic and a task marked for ceasing activity may have ended or completed its processing before the cease action could be completed. In most cases these errors are minor and can be ignored. However, if these errors persist, contact Compuware Customer Support.
00000001 - Requested TP id was not numeric
00000002 - Requested TP id does not belong to the signed on userid.
00000003 - Requested TP id not found (no longer active)
00000004 - Requested TP id is in WAIT state (long running work already complete)
Reference: None.
RC=947
Reason=X'rrrrrrrr'
Meaning: When attempting to copy data across LPARs, an error occurred trying to initialize TCP/IP communications for the copy operation.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server: IP Sockets Application Programming Interface Guide and Reference SC31-
8788. Refer to Appendix B: Socket Call Error Return Codes. The rrrrrrrr value is the ERRNO return code referenced in the Appendix. The TCP/IP macro issued was EZASMI INITAPI.
RC=948
Reason=X'rrrrrrrr'
Meaning: When attempting to copy data across LPARs, an error occurred trying to initialize TCP/IP communications for the copy operation.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server: IP Sockets Application Programming Interface Guide and Reference SC31-
8788. Refer to Appendix B: Socket Call Error Return Codes. The rrrrrrrr value is the ERRNO return code referenced in the Appendix. The TCP/IP macro issued was EZASMI SOCKET.
RC=949
Reason=X'rrrrrrrr'
Compuware Workbench Messages and Codes
I-55
Meaning: When attempting to copy data across LPARs, an error occurred trying to validate the parameters related to the copy.
Action: Probable user error. A number of validations are performed on dataset types and internal dataset DCB information to ensure compatibility during copy operations. Look up the reason code in the list below to determine the cause and corrective action.
Reference: RC 949 validation error reasons can be found in the table below. In the descriptions, the references FROM dataset and TO dataset refer to the source and destination datasets specified in the copy operation, respectively.
E
F
10
11
12
13
Reason (hex) Description
1 The IP number specified is invalid. The IP number is not correctly formatted in dotted IP number format; e.g., xxx.xxx.xxx.xxx. Correct the IP number specification and retry the copy operation.
2
3
The port number of the remote host is invalid (non-numeric or not in the range of 1-65535).
Correct the port number specification and retry the copy operation.
Unable to sign-on to remote host. During sign-on a security error was encountered, probably due to an invalid userid or password being specified. Correct the userid and password for the remote host and retry the copy operation.
4
5
6
7
Unable to sign-on to remote host because the remote host is not at the correct maintenance level to support cross-LPAR dataset copy operations.
During the initiation of a copy operation, an acknowledgement to the initiation request was not receiving from the remote HCI. Contact Compuware for assistance.
During the various request/responses transmitted during a copy operation, one of the responses did not acknowledge the request. Contact Compuware for assistance.
During a copy operation one of the copy requests was issued out of sequence. Contact
Compuware for assistance.
8
9
A
B
C
D
The dataset being copied (the FROM dataset) is of an invalid DSORG type. Only DSORG PS, PO or VSAM datasets can be copied.
The dataset being copied (the FROM dataset) was not partitioned, even though member names were specified on the copy request.
A copy operation was attempted that implies the use of sequential datasets, but a sequential dataset was not specified as the FROM dataset.
The destination dataset (the TO dataset) is of an invalid DSORG type. Only DSORG PS, PO or
VSAM datasets can be copied.
The destination dataset (the TO dataset) was not partitioned, even though member names were specified on the copy request.
A copy operation was attempted that implies the use of sequential datasets, but a sequential dataset was not specified as the destination dataset (TO dataset).
The FROM dataset LRECL is less than the TO dataset LRECL.
The FROM dataset LRECL is greater than the TO dataset LRECL.
Cannot copy a sequential or partitioned dataset into a VSAM dataset.
Cannot copy a VSAM dataset into a non-VSAM dataset.
The source dataset (FROM dataset) is VSAM but is of an unsupported type.
The source dataset (FROM dataset) is VSAM and the destination dataset (TO dataset) is also
VSAM, however, they are not the same VSAM type. The copy operation only supports VSAM copy of the same type, e.g., KSDS-to-KSDS, LINEAR-to-LINEAR, etc.
I-56
Compuware Workbench Installation Guide
Reason (hex) Description
14 The source dataset (FROM dataset) maximum record size is greater than the destination dataset
(TO dataset) maximum record size.
15
16
The source dataset (FROM dataset) and destination dataset (TO dataset) key lengths are not equal.
The source dataset (FROM dataset) and destination dataset (TO dataset) key positions are not identical.
17 Cross-LPAR copy support programming on the source-side is not at the same version as the copy support programming on the destination-side. The copy cannot proceed due to this incompatibility. Both the source and destination sides should be brought to the same current maintenance levels.
RC=950
Reason=X'rrrrrrrr'
Meaning: When attempting to copy data across LPARs, an error occurred trying to determine the IP number of a named host.
Action: Probable TCP/IP configuration error. The named host may not be in the site defined host name tables.
Ensure the host name specified is valid, or that the host name is correctly specified in the host name tables.
Reference: z/OS Communications Server: IP Sockets Application Programming Interface Guide and Reference SC31-
8788. Refer to Appendix B: Socket Call Error Return Codes. The rrrrrrrr value is the ERRNO return code referenced in the Appendix. Reason code FFFFFFFF means the host name tables did not contain a valid IP number. The TCP/IP macro issued was EZASMI GETHOSTBYNAME.
RC=951
Reason=X'rrrrrrrr'
Meaning: When attempting to copy data across LPARs, an error occurred trying to initialize TCP/IP communications for the copy operation.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server: IP Sockets Application Programming Interface Guide and Reference SC31-
8788. Refer to Appendix B: Socket Call Error Return Codes. The rrrrrrrr value is the ERRNO return code referenced in the Appendix; the TCP/IP macro issued was EZASMI CONNECT.
RC=952
Reason=X'rrrrrrrr'
Meaning: When attempting to copy data across LPARs, an error occurred trying to write to the TCP/IP socket.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server: IP Sockets Application Programming Interface Guide and Reference SC31-
8788. Refer to Appendix B: Socket Call Error Return Codes. The rrrrrrrr value is the ERRNO return code referenced in the Appendix. The TCP/IP macro issued was EZASMI WRITE.
RC=953
Reason=X'rrrrrrrr'
Meaning: When attempting to copy data across LPARs, an error occurred trying to read from the TCP/IP socket.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server: IP Sockets Application Programming Interface Guide and Reference SC31-
8788. Refer to Appendix B: Socket Call Error Return Codes. The rrrrrrrr value is the ERRNO return code referenced in the Appendix. The TCP/IP macro issued was EZASMI READ.
RC=954
Reason=X'rrrrrrrr'
Compuware Workbench Messages and Codes
I-57
Meaning: When attempting to copy data across LPARs, an error occurred trying to take the socket connection from the HCI.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS Communications Server: IP Sockets Application Programming Interface Guide and Reference SC31-
8788. Refer to Appendix B: Socket Call Error Return Codes. The rrrrrrrr value is the ERRNO return code referenced in the Appendix. The TCP/IP macro issued was EZASMI TAKESOCKET.
RC=955
Reason=X'rrrrrrrr'
Meaning: When attempting to copy data across LPARs, an error occurred trying to access the source dataset (FROM dataset) because access was failed by system security.
Action: Dataset access has been denied by the system security product. Contact your installation's security personnel.
The reason code is the return code from the System Authorization Facility (SAF). The rrrr value is the SAF return code, and the ssss value is the SAF reason code.
Reference: None.
RC=956
Reason=X'rrrrrrrr'
Meaning: When attempting to copy data across LPARs, an error occurred trying to access the destination dataset TO dataset) because access was failed by system security.
Action: Dataset access has been denied by the system security product. Contact your installation's security personnel.
The reason code is the return code from the System Authorization Facility (SAF). The rrrr value is the SAF return code, and the ssss value is the SAF reason code.
Reference: None.
RC=957
Reason=X'eeeeiiii'
Meaning: During an attempt to copy data across LPARs, a failure occurred trying to allocate the source (FROM) dataset.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=958
Reason=X'eeeeiiii'
Meaning: During an attempt to copy data across LPARs, a failure occurred trying to allocate the destination (TO) dataset.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=959
Reason=X'rrrrrrrr'
Meaning: An attempt to enqueue on the destination (TO) dataset for the purpose of copying data has failed.
Action: The dataset is probably in use by the same or a different user. Check the reason code below to determine possible causes. If the code is not listed, this is a probable environmental error and should be resolved by your system programming personnel. The dataset is probably enqueued by another job elsewhere in the system.
00000004 -Exclusive control of the dataset could not be obtained
Reference: z/OS MVS Programming: Assembler Services SA22-7606. Refer to the ENQ macro and its list of return codes. The reason code rrrrrrrr is the ENQ return code.
I-58
Compuware Workbench Installation Guide
RC=960
Reason=X'rrrrrrrr'
Meaning: During an attempt to open the source dataset (FROM dataset) in a cross-LPAR copy, the OPEN macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=961
Reason=X'rrrrrrrr'
Meaning: During an attempt to open the destination dataset (TO dataset) in a cross-LPAR copy, the OPEN macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=962
Reason=X'rrrrssss'
Meaning: When attempting to copy dataset members across LPARs, a failure occurred trying to locate the source member's directory information.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the BLDL macro and its list of return codes. The reason code values rrrr and ssss are the return and reason codes from the BLDL macro, respectively.
RC=962
Reason=X'rrrrssss'
Meaning: When attempting to copy dataset members across LPARs, a failure occurred trying to determine if the same member exists in the destination (FROM) dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the FIND macro and its list of return codes. The reason code values rrrr and ssss are the return and reason codes from the FIND macro, respectively.
RC=965
Reason=X'00000004'
Meaning: During a cross-LPAR copy request, a member was not replaced.
Action: The member was not replaced because the Replace option was not specified. This is not an error in copying or moving the member, rather it is only an indication that the request did not succeed because the member could not be replaced.
Reference: None.
RC=966
Reason=X'rrrrrrrr'
Meaning: When attempting to copy a dataset with cross-LPAR copy, a read operation against the source (FROM) dataset has failed.
Action: Probable I/O or environmental error. Investigate the HCI job log for unusual error messages and/or abend codes, such as S 001-xx. This can be a difficult error to diagnose. The reason code is the first four bytes of the DECB after a BSAM/BPAM READ/CHECK macro has completed. This return code will be issued whenever the post code within the DECB (the first byte of the reason code) is not equal to X'7F'. The X'7F' value is considered a successful read and any other value is an error condition. If the error cannot be determined, contact Compuware Customer
Support for assistance and provide the reason code as well as any other requested documentation related to the problem.
Compuware Workbench Messages and Codes
I-59
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408, and z/OS DFSMS Using Data Sets SC26-7410.
Refer to the READ and CHECK macros and the processing of sequential and partitioned datasets. The reason code value is the first 4 bytes of the DECB after the CHECK macro completes.
RC=967
Reason=X'rrrrrrrr'
Meaning: When attempting to copy a dataset with cross-LPAR copy, a write operation against the destination (TO) dataset has failed.
Action: Probable I/O or environmental error. Investigate the HCI job log for unusual error messages and/or abend codes, such as S 001-xx. This can be a difficult error to diagnose. The reason code is the first four bytes of the DECB after a BSAM/BPAM WRITE/CHECK macro has completed. This return code will be issued whenever the post code within the DECB (the first byte of the reason code) is not equal to X'7F'. The X'7F' value is considered a successful write and any other value is an error condition. If the error cannot be determined, contact Compuware Customer
Support for assistance and provide the reason code as well as any other requested documentation related to the problem.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408, and z/OS DFSMS Using Data Sets SC26-7410.
Refer to the WRITE and CHECK macros and the processing of sequential and partitioned datasets. The reason code value is the first 4 bytes of the DECB after the CHECK macro completes.
RC=968
Reason=X'rrrrssss'
Meaning: During a cross-LPAR copy operation, an attempt to add or replace a member of a partitioned dataset as failed.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the STOW macro (A and R forms) and its list of return codes. The reason code rrrr is the STOW return code and ssss is the STOW reason code.
00040000 - The member name to be added already exists
000C0000 - No space exists in the partitioned dataset directory.
001C0000 - Cannot add or replace a member to a PDSE program library. This is a Host Explorer restriction.
00280000 - Attempted to copy into a program library PDSE. This is a Host Explorer restriction.
RC=969
Reason=X'rrrrssss'
Meaning: During a cross-LPAR copy operation, an attempt to add or replace a member alias of a partitioned dataset as failed.
Action: Check the return codes listed below for a probable cause. If the code is not listed, contact Compuware
Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the STOW macro (A and R forms) and its list of return codes. The reason code rrrr is the STOW return code and ssss is the STOW reason code.
00040000 - The member name to be added already exists
000C0000 - No space exists in the partitioned dataset directory.
RC=970
Reason=X'rrrrssss'
Meaning: During an attempt to open the VSAM source dataset (FROM dataset) in a cross-LPAR copy, the OPEN macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
OPEN macro and its list of return codes in Chapter 3 which describes both the OPEN return codes and the ACBERFLG codes. The reason code rrrr is the OPEN return code, and the ssss value is the value returned in ACBERFLG. One commonly seen reason code:
I-60
Compuware Workbench Installation Guide
000800A0 - The source dataset is empty (contains no records to copy)
RC=971
Reason=X'rrrrssss'
Meaning: During an attempt to open the VSAM destination dataset (TO dataset) in a cross-LPAR copy, the OPEN macro has failed.
Action: The most likely cause is the destination dataset is not reusable; check the return code to see if it matches the return code described below. If it does, this dataset cannot be the target of a copy because it is not reusable. For other return codes, this is a probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
OPEN macro and its list of return codes in Chapter 3 which describes both the OPEN return codes and the ACBERFLG codes. The reason code rrrr is the OPEN return code, and the ssss value is the value returned in ACBERFLG. One commonly seen reason code:
000800E8 - The destination dataset is not empty and does not have the REUSE attribute.
RC=972
Reason=X'00xxyyzz'
Meaning: During an attempt to determine the type of the VSAM destination dataset (TO dataset) in a cross-LPAR copy, the type and its attributes were not identified.
Action: Ensure the type of destination VSAM dataset is one of KSDS, RRDS, ESDS, or LINEAR. Any other type is not supported. If the VSAM type is one of the four supported types and this error occurs, contact Compuware Customer
Support and provide the reason code.
Reference: None.
RC=973
Reason=X'00xxyyzz'
Meaning: During an attempt to determine the type of the VSAM source dataset (FROM dataset) in a cross-LPAR copy, the type and its attributes were not identified.
Action: Ensure the type of source VSAM dataset is one of KSDS, RRDS, ESDS, or LINEAR. Any other type is not supported. If the VSAM type is one of the four supported types and this error occurs, contact Compuware Customer
Support and provide the reason code.
Reference: None.
RC=974
Reason=X'xxxxyyyy'
Meaning: During an attempt to read a record from the VSAM source dataset (FROM dataset) in a cross-LPAR copy, the
GET macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
RPL based list of return codes in Chapter 3 which describes both the GET/PUT return codes and reason codes. The reason code xxxx is the GET return code, and the yyyy value is the value returned in RPLERRCD.
RC=975
Reason=X'xxxxyyyy'
Meaning: During an attempt to write a record to the VSAM destination dataset (TO dataset) in a cross-LPAR copy, the
PUT macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 1 VSAM Macro Instructions. Refer to the
RPL based list of return codes in Chapter 3 which describes both the GET/PUT return codes and reason codes. The reason code xxxx is the PUT return code, and the yyyy value is the value returned in RPLERRCD.
RC=999
Reason=X'00000000'
Compuware Workbench Messages and Codes
I-61
Meaning: An unknown request was received.
Action: Internal error. Contact Compuware Customer Support.
Reference: None.
RC=1001
Reason=X'00000000'
Meaning: The user does not have access authority to the specified dataset. The search attempt is aborted.
Action: Obtain proper access to the dataset or search a different dataset.
Reference: None.
RC=1002
Reason=X'00000001'
Meaning: The user requesting a search has submitted an improper or invalid text string for the search argument.
Action: Specify the search argument with proper syntax as documented by Host Explorer online documentation.
Reference: None.
RC=1003
Reason=X'eeeeiiii'
Meaning: During an attempt to allocate a dataset to be searched the dynamic allocation request has failed.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
RC=1004
Reason=X'0000000x'
Meaning: During an attempt to search a dataset, a validation error occurred related to the organization of the dataset.
Action: Review the reason code below. Only DSORG=PS or PO datasets can be searched and these datasets must not specify RECFM=VBS or records larger than 32760 bytes.
Reference: Possible reason code values:
00000001 - DSORG of specified dataset is not PS or PO.
00000002 - The dataset DSORG is PS but a member name list was specified.
00000003 - The dataset contains RECFM=VBS records.
00000004 - The dataset contains records larger than 32760 bytes.
RC=1005
Reason=X'rrrrrrrr'
Meaning: During an attempt to open a dataset to be searched, the OPEN macro has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=1006
Reason=X'rrrrrrrr'
Meaning: When attempting to read a dataset or member during a search request, the read has failed.
Action: Probable I/O or environmental error. Investigate the HCI job log for unusual error messages and/or abend codes, such as S 001-xx. This can be a difficult error to diagnose. The reason code is the first four bytes of the DECB
I-62
Compuware Workbench Installation Guide
after a BSAM/BPAM READ/CHECK macro has completed. This return code will be issued whenever the post code within the DECB (the first byte of the reason code) is not equal to X'7F'. The X'7F' value is considered a successful read and any other value is an error condition. If the error cannot be determined, contact Compuware Customer
Support for assistance and provide the reason code as well as any other requested documentation related to the problem.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408, and z/OS DFSMS Using Data Sets SC26-7410.
Refer to the READ and CHECK macros and the processing of sequential and partitioned datasets. The reason code value is the first 4 bytes of the DECB after the CHECK macro completes.
RC=1007
Reason=X'0000000'
Meaning: When attempting to read a partitioned dataset directory during a search request, the directory read has failed.
Action: Probable I/O or environmental error. Investigate the HCI job log for unusual error messages and/or abend codes, such as S 001-xx. If the error cannot be determined, contact Compuware Customer Support for assistance and provide any other requested documentation related to the problem.
Reference: None.
RC=1360
Reason=X'eeeeiiii'
Meaning: During error recovery, dynamic allocation failed for the dump dataset.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=1364
Reason=X'rrrrrrrr'
Meaning: During error recovery, an attempt to open the dump dataset has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=1500
Reason=X'00000000'
Meaning: The TP is not APF-authorized and therefore cannot issue service requests to start up the SSAS address space.
Action: Add the dataset containing the TP load module (CXTPMAIN) to the APF dataset list.
Reference: None.
RC=1504
Reason=X'rrrrrrrr'
Meaning: During SSAS start-up, a request was issued to locate the name/token pair passed by the TP requesting services, but an error occurred.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Programming: Assembler Services Reference SA22-7607. Refer to the IEANTRT macro and its list of return codes. The reason code rrrrrrrr is the IEANTRT.
RC=1508
Reason=X'rrrrssss'
Meaning: During an attempt to start-up the SSAS, the address space creation macro ASCRE has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the ASCRE macro and its list of return codes and reason codes. The reason code rrrr is the return code from ASCRE, and the reason code ssss is the reason code from ASCRE.
Compuware Workbench Messages and Codes
I-63
RC=1512
Reason=X'00000000'
Meaning: During an attempt to start-up the SSAS, the SSAS terminated unexpectedly.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None.
RC=1516
Reason=X'rrrrrrrr'
Meaning: During an attempt to start-up the SSAS, an attempt was made to establish cross-memory communication between the TP and the SSAS, the attempt failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the ALESERV macro and its list of return codes and reason codes. The reason code rrrrrrrr is the return code from ALESERV.
RC=1520
Reason=X'rrrrrrrr'
Meaning: During an attempt to start-up the SSAS, cross-memory communication between the TP and the SSAS was established but the two sides could not be synchronized. A cross-memory POST has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7611. Refer to the POST macro and its list of return codes and reason codes. The reason code rrrrrrrr is the return code from the cross-memory from of POST.
RC=1524
Reason=X'rrrrrrrr'
Meaning: During an attempt to pass a work request to the SSAS, a cross-memory POST has failed after placing the work on the SSAS work queue.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS MVS Authorized Assembler Services Reference SA22-7611. Refer to the POST macro and its list of return codes and reason codes. The reason code rrrrrrrr is the return code from the cross-memory from of POST.
RC=1528
Reason=X'00000000'
Meaning: During an attempt to pass a work request to the SSAS, the work queue was found to be full. Currently, the work queue can hold a maximum of 64 simultaneous work requests.
Action: Retry the request after a few seconds. If the error persists, contact Compuware Customer Support.
Reference: None.
RC=1532
Reason=X'rrrrrrrr'
Meaning: During an attempt to start-up the SSAS or the SSAUTH, the address space could not continue because no procedure name or no SSAS names were assigned in the TP Configuration File.
Action: Ensure that the SSAS and/or SSAUTH procedure names, and the SSAS/SSAUTH names are assigned in the TP
Configuration File. The possible reason codes are:
00000001 - No procedure name found for SSAS
00000002 - No SSAS name found
Reference: See section, “Create and Manage the CSS TP Configuration Member” on page F-1.
RC=1560
Reason=X'eeeeiiii'
Meaning: During a request to retrieve the contents of a DDIO source listing member, the allocation request has failed for the DDIO file that contains the requested member.
I-64
Compuware Workbench Installation Guide
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
RC=1564
Reason=X'rrrrrrrr'
Meaning: During a request to retrieve the contents of a DDIO source listing member, an attempt to establish the SLS environment failed.
Action: The requested source listing member was most likely not found in the DDIO file. Otherwise, this is a probable internal error. Contact Compuware Customer Support and provide the reason code. Possible reason codes are:
0000008C - GETMAIN macro failure
00000090 - LOAD macro failure
00000094 - FREEMAIN macro failure
00000098 - DELETE macro failure
0000009C - Invalid CSS release number
000000A0 - Invalid Compuware product code
000000B0 - DDNAME missing
Reference: None.
RC=1568
Reason=X'rrrrrrrr'
Meaning: During a request to retrieve the contents of a DDIO source listing member, an attempt to open the member within the SLS environment failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code. Possible reason codes are:
00000004 - No listing member found
0000008C - GETMAIN macro failure
00000094 - FREEMAIN macro failure
000000B0 - DDNAME missing
Reference: None.
RC=1572
Reason=X'rrrrrrrr'
Meaning: During a request to retrieve the contents of a DDIO source listing member, an attempt to retrieve a block of lines from the member has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code. Possible reason codes are:
0000000C - Internal table not found for retrieving lines
00000014 - Invalid line number (past end of the member)
00000030 - Line number requested not found
00000050 - A dataname within the line could not be resolved
0000008C - GETMAIN macro failure
00000094 - FREEMAIN macro failure
Reference: None.
Compuware Workbench Messages and Codes
I-65
RC=1580
Reason=X'eeeeiiii'
Meaning: During a request to retrieve the directory contents of a DDIO source listing file, the allocation request has failed for that DDIO file.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
RC=1584
Reason=X'rrrrrrrr'
Meaning: During a request to retrieve the directory of a DDIO source listing file, an attempt to establish the necessary environment failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code. Possible reason codes are:
0000000C - GETMAIN macro failure
Reference: None.
RC=1588
Reason=X'rrrrrrrr'
Meaning: During a request to retrieve the directory of a DDIO source listing file, an attempt to read the directory has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: Compuware Enterprise Common Components (ECC) Messages and Codes. Refer to the section titled MVS
DDIO and Interface Manager Return Codes.
RC=1592
Reason=X'rrrrrrrr'
Meaning: During a request to retrieve the directory of a DDIO source listing file, an access attempt failed because the
DDIO file specified is not a source-type DDIO file.
Action: Select a DDIO file, DDIO shared directory, or DDIO database that has been formatted for use as a source listing repository. The reason code rrrrrrrr indicates the type of DDIO file that was specified (which was not a sourcetype). The only valid types for reason code are X'0B', X'15', and X'1F', and since they are valid, they should never be returned with return code 1592. Any other reason code value is considered to be an invalid or unsupported type of
DDIO file. Specify a source-type DDIO file and retry the request.
Reference: None.
RC=1600
Reason=X'eeeeiiii'
Meaning: During a request to lock, unlock, or delete a source listing member from a DDIO source listing file, the allocation request has failed for that DDIO file.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value. Commonly received reason codes:
0278 0000 - The dataset was migrated. Recall the dataset and retry.
1708 0002 - The dataset does not exist. Specify a different dataset.
I-66
Compuware Workbench Installation Guide
RC=1604
Reason=X'rrrrrrrr'
Meaning: During a request to process a member of a DDIO source listing file, an attempt to establish the necessary environment failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code. Possible reason codes are:
0000000C - GETMAIN macro failure
Reference: None.
RC=1608
Reason=X'rrrrrrrr'
Meaning: During a request to process a member of a DDIO source listing file, the open request has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: Compuware Enterprise Common Components (ECC) Messages and Codes. Refer to the section titled MVS
DDIO and Interface Manager Return Codes.
RC=1612
Reason=X'rrrrrrrr'
Meaning: During a request to lock, unlock, or delete a source listing member from a DDIO source listing file, an access attempt failed because the DDIO file specified is not a source-type DDIO file.
Action: Select a DDIO file, DDIO shared directory, or DDIO database that has been formatted for use as a source listing res po si tory. The reason code rrrrrrrr indicates the type of DDIO file that was specified (which was not a source-type). The only valid types for reason code are X'0B', X'15', and X'1F', and since they are valid, they should never be returned with return code 1612. Any other reason code value is considered to be an invalid or unsupported type of DDIO file. Specify a source-type DDIO file and retry the request.
Reference: None.
RC=1616
Reason=X'rrrrrrrr'
Meaning: During a request to lock, unlock, or delete a source listing member from a DDIO source listing file, the specific request has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code. Possible return codes are:
0000000C - GETMAIN macro failure
00000010 - DDIO file not open
0000002C - Specified DDIO member does not exist
00000030 - Specified member in use
0000003C - Member designated read-only
000000E0 - Copy, Move, or Import operation in progress on this member
000000E4 - Member being created by another process
00000FFC - Internal DDIO error
Reference: None.
RC=1620
Reason=X'00000000'
Meaning: During a request to lock, unlock, or delete a source listing member from a DDIO source listing file, the listing number associated with the request was not numeric.
Action: Internal error. The DDIO listing number passed by Host Explorer must be numeric. This is a Host Explorer logic error. Contact Compuware Customer Support.
Reference: None.
Compuware Workbench Messages and Codes
I-67
RC=1628
Reason=X'rrrrrrrr'
Meaning: During a request to create a new shared directory and database, either the shared directory information, or the database information, was not located in the parameter information received from the user workstation.
Action: Internal error. Contact Compuware Customer Support and provide the reason code. The reason codes are:
00000001 - Shared directory information not located
00000002 - Database information not located
Reference: None.
RC=1632
Reason=X'eeeeiiii'
Meaning: During a request to create a new shared directory and database, an attempt to allocate a temporary dataset to hold control information has failed during dynamic allocation.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=1636
Reason=X'rrrrrrrr'
Meaning: During a request to create a new shared directory and database, an attempt to open a temporary dataset used to contain control information has failed.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: z/OS DFSMS Macro Instructions for Datasets SC26-7408. Part 2 Non-VSAM Macro Instructions. Refer to the OPEN macro and its list of return codes. The reason code rrrrrrrr is the OPEN return code.
RC=1640
Reason=X'eeeeiiii'
Meaning: During a request to create a new shared directory and database, an attempt to allocate a SYSOUT dataset to contain utility output has failed during dynamic allocation.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=1644
Reason=X'eeeeiiii'
Meaning: During a request to create a new shared directory and database, an attempt to allocate the new shared directory has failed during dynamic allocation.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=1648
Reason=X'eeeeiiii'
Meaning: During a request to create a new shared directory and database, an attempt to allocate the new database has failed during dynamic allocation.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: z/OS MVS Authorized Assembler Services Guide SA22-7608. Chapter 25 "Dynamic Allocation". The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
I-68
Compuware Workbench Installation Guide
RC=1652
Reason=X'rrrrrrrr'
Meaning: During a request to create a new shared directory and database, the IDCAMS utility was called to allocate the new datasets. IDCAMS has failed during the creation request.
Action: The workstation user is presented an opportunity to view the output from IDCAMS which should indicate the reason for the error. Usually, this type of error will occur when one or more of the parameters needed to create these datasets is missing or invalid. This output can also be viewed with an appropriate output viewing utility on the mainframe; the output is located as one of the DD names associated with the Shared Services Address Space procedure
(SSAS).
Reference: z/OS DFSMS Access Method Services, SC26-7394. Refer to the chapter associated with DEFINE CLUSTER along with the IDCAMS output. The reason code rrrrrrrr is the return code received from IDCAMS.
RC=1656
Reason=X'rrrrrrrr'
Meaning: During a request to create a new shared directory and database, the CWDDALLU utility was called to format the new datasets. CWDDALLU has failed during the format request.
Action: The workstation user is presented an opportunity to view the output from CWDDALLU which should indicate the reason for the error. Usually, this type of error will occur when one or more of the parameters needed to create these datasets is missing or invalid. This output can also be viewed with an appropriate output viewing utility on the mainframe; the output is located as one of the DD names associated with the Shared Services Address Space procedure
(SSAS).
Reference: Compuware Shared Services User/Reference Guide, MVS Version (see the chapter titled, "CWDDALLU"). Refer to the chapter associated with CREATE OBJECT=SRCRDIR and CREATE OBJECT=DATABASE along with the utility's output. Also, refer to the Enterprise Common Components (ECC) Messages and Codes manual for any error messages issued by the utility. The reason code rrrrrrrr is the return code received from the utility.
RC=1660
Reason=X'eeeeiiii'
Meaning: During a request to create a new shared directory and database, an attempt to allocate a SYSOUT dataset to contain utility output has failed during dynamic allocation.
Action: This is a dynamic allocation failure. Look up the reason code in the reference manual below to determine the action.
Reference: IBM’s z/OS MVS Authorized Assembler Services Guide SA22-7608 (see Chapter 25, "Dynamic Allocation".
The reason code is two parts: eeee is the S99ERROR value, and iiii is the S99INFO value.
RC=1901
Reason=X'rrrrrrrr'
Meaning: An XML parsing failure has occurred.
Action: This is an internal error. Contact Compuware Customer Support for assistance.
Reference: None.
RC=1902
Reason=X'00000000'
Meaning: Task table is full. File-AID has requested too many tables or files to be open at once.
Action: Reduce the number of open DB2 tables or files.
Reference: None.
RC=1903
Reason=X'rrrrrrrr'
Meaning: Data was received for a task that no longer exists.
Action: This is an internal error. Contact Compuware Customer Support for assistance.
Reference: None.
Compuware Workbench Messages and Codes
I-69
RC=1904
Reason=X'rrrrssss'
Meaning: When sending data from the mainframe to Mainframe Modernization Components, an error occurred during the conversion of the data from EBCDIC to UTF-8.
Action: Probable internal error. Contact Compuware Customer Support and provide the reason code.
Reference: None.
Messages
These messages could appear on the HCI job log output during execution. These messages are issued by the CSS TP servicing Host Explorer and Xpediter/Eclipse users.
Each of the messages contains a message ID starting with CX and is followed by a 4-digit number representing the task number. The task number can be used to group messages issued by the various TPs in execution.
Message Format:
CXxxmmm###s nnnn message-text
Where:
CX is the CSS identifier
xx is one of TP or AS. TP is the CSS TP, AS is the SSAS.
mmm is the module csect id issuing the message
### is the message number
s is the severity code (I=informational, W=warning, S=severe)
nnnn is the subtask number for the life of this TP or AS subtask
CXASDSP024I command received from userid
Meaning: The SSAS received an operator console command from the specified userid.
Action: None.
CXASDSP028W Journal task not active; restart SSAS to activate
Meaning: Journaling could not start for the SSAS because the journal task is not active. The journal task can fail to start if it cannot allocate or open the journal datasets, or if no SSAS journal datasets were specified in TP Configuration
File. Processing continues normally, but without journaling.
Action: Verify the journal dataset exists, and that it has universal update access and shutdown the SSAS with the MVS
STOP command. It will restart automatically on the next request from a client user.
CXASDSP030W Request not recognized; input ignored
Meaning: A MVS MODIFY command was issued to the SSAS, but the command was not recognized. Processing continues.
Action: Reenter the command with the proper input parameters.
CXASDSP031I CXTRACE request active for userid userid
Meaning: A MVS MODIFY command was issued to the SSAS to start a CXTRACE at the request of Compuware
Customer Support.
Action: None
CXASDSP032I CXTRACE request ignored; currently active for user userid
Meaning: A MVS MODIFY command was issued to the SSAS to start a CXTRACE but the trace was already active.
Processing continues with CXTRACE active.
Action: None
I-70
Compuware Workbench Installation Guide
CXASDSP033I CXTRACE now inactive
Meaning: A MVS MODIFY command was issued to the SSAS to stop an active CXTRACE.
Action: None
CXASINI020I ssasname initialization complete
Meaning: The SSAS has successfully started and is ready for use. The ssasname is the name specified in the TP
Configuration File member.
Action: None.
CXASINI034I ssasname is running APF-authorized
Meaning: The SSAS is operating with APF-Authorization. The SSAS does not currently require APF-authorization and some routines may not execute properly in this environment.
Action: None, but it is recommended that SSAS run non-authorized.
CXASJRN021I Journal now recording to dataset name
Meaning: The SSAS journal dataset successfully.
Action: None.
CXASJRN022I Journal dataset name closed
Meaning: The SSAS journal dataset has been closed successfully.
Action: None.
CXASJRN025S No JOURNAL datasets defined
Meaning: No SSAS journal datasets were defined in the TP Configuration File member. Processing continues without journaling.
Action: None.
CXASJRN026S Could not allocate dataset name,
Meaning: A SSAS journal dataset specified in TP Configuration File member could not be allocated. This message is followed by CXASJRN044S. A user abend 0027 is issued, but processing continues without journaling.
Action: Verify the journal dataset exists, and that it has universal update access.
CXASJRN027S Could not open dataset name,
Meaning: A SSAS journal dataset specified in TP Configuration File member could not be opened. This message is followed by CXASJRN045S. A user abend 0027 is issued, but processing continues without journaling.
Action: Verify the journal dataset exists, and that it has universal update access.
CXASJRN029S Journal write RPL error X''xx''
Meaning: An RPL occurred attempting to write a journal record. The RPL error code is from the VSAM PUT macro.
Processing continues normally, but without journaling.
Action: Reallocating the SSAS journal datasets and restarting the SSAS may help. If the error persists, contact
Compuware Customer Support.
CXASJRN044S Allocation S99ERROR=X''xx''
Meaning: A SSAS journal dataset specified in TP Configuration File member could not be allocated. This message is preceded by CXASJRN026S. A user abend 0027 is issued, but processing continues without journaling. The S99ERROR value specified the dynamic allocation error code.
Action: Verify the journal dataset exists, and that it has universal update access.
CXASJRN045S Journal task abend forced
Meaning: SSAS is unable to start journaling. The journal task is terminated with a user 0027 abend, and processing continues without journaling.
Action: None.
Compuware Workbench Messages and Codes
I-71
CXASREQ007S Term RC=% FDBK=% Reason=% z=% mms
Meaning: A SSAS subtask has terminated. The last return code and reason code processed while the task was executing is shown in the FDBK= and Reason= fields. The z= field shows the amount of zIIP processing time consumed by the TP subtask during execution, in microseconds (if zIIP processing is enabled, otherwise this value is 0). The z= value will always be 0 for SSAS tasks.
indicative only that an error occurred, and does not contain a useful value. Use only the FDBK and Reason values
when looking up the error in “Return Codes” on page I-1. (Note: FDBK = RC and Reason = Reason).
CXASREQ035I Req = code function userid
Meaning: A diagnostic aid message that indicates the current SSAS function being requested by a client user. The code is the function code output by the XML parser and the function value is high level name of the function to be performed. This message is only informational.
Action: None.
CXASSTA011S Abend abend-code
Meaning: During SSAS subtask execution, an abend was encountered. An abend dump is produced and is available in the HCI sysout with a ddname of TPnnnn where nnnn is the task number of this TP identified in the message.
Action: Most abends can be ignored unless they persist. Contact Compuware Customer Support if necessary.
CXTPCFG001S Open failed on configuration dataset
Meaning: The CSS TP Configuration File dataset could not be opened.
Action: Verify that the dataset is created and the configuration member exists. Verify that the dataset has universal
READ access. Verify that the TPCONFIG DD statement exists in the HCI start-up JCL stream and that it specifies this dataset.
CXTPCFG002W Configuration parameter cannot begin in column 1
Meaning: An unexpected character was found in column 1 of the configuration member.
Action: Column 1 of the configuration member can only contain an asterisk character, indicating a comment, or a blank character. All parameters specified in the member must begin in any other column.
CXTPCFG003W Error parsing configuration parameter in record x
Meaning: An unexpected error was encountered examining the parameters specified in the configuration member.
Action: Each parameter statement must begin after column 1, and all subsequent parameters on the line must be separated by one or more blanks. Other than the blank separation, the record is free form and data can begin in any column except column 1.
This message is followed by CXTPCFG004W which shows a portion of the failing record.
CXTPCFG004W RECORD=" record text "
Meaning: This message follows a prior message indicating an error processing the configuration member. The record text shows a portion of the failing record.
Action: Correct the failing record using the syntax of the parameter as described in the configuration steps of the
Installation Guide.
CXTPCFG005W Unknown configuration parameter specified in record x
Meaning: An unidentified configuration parameter was encountered examining the parameters specified in the configuration member.
Action: Check the parameter against those listed in the Installation Guide and correct the error. This message is followed by CXTPCFG004W which shows a portion of the failing record.
CXTPCFG006S Maximum number of configuration entries (100) exceeded
Meaning: When processing the configuration member, more than 100 total HCI, TSO, and CICS entries were scanned. Currently, the limit is 100 entries, in any combination.
Action: Check the configuration member for unused or unnecessary entries and remove them. Contact Compuware
Customer Support if more entries are required.
I-72
Compuware Workbench Installation Guide
CXTPCFG017S Member mmmmmmmm not found in dataset DD TPCONFIG (FIND RC=04)
Meaning: When attempting to process the TP Configuration File member, the member could not be located.
Action: Verify that the dataset is created and the configuration member exists. Verify that the dataset has universal
READ access. Verify that the TPCONFIG DD statement exists in the HCI start-up JCL stream and that it specifies this dataset. Verify that the member name is identical to the name of the TP (TPNAME parameter value on the HCICNPCB macro in the HCI Configuration).
CXTPCFG018S FIND member mmmmmmmm failed in DD TPCONFIG, R15=xx, R0=xx
Meaning: When attempting to process the TP Configuration File member, an error occurred trying to locate the member.
Action: This message usually indicates some type of I/O error when trying to read a PDS directory. The R15 and R0 values are the return and reason codes from the FIND macro. Contact Compuware Customer Support for assistance.
CXTPCFG019I Configuration file % successfully processed
Meaning: The TP Configuration File member was successfully processed and is now active.
Action: None.
CXTPCFG023W Additional JOURNAL datasets ignored (3 max)
Meaning: In the TP Configuration file member, more than three JOURNAL statements are specified. The maximum number of JOURNAL statements that can be specified is three.
Action: Remove the extra JOURNAL statements from the configuration file member and refresh the configuration using the TPAdmin utility or restart the HCI.
CXTPCFG046S zIIP parameter must specify either Y or N
Meaning: The zIIP parameter within the TP Configuration File's LOCAL statement must specify a value of Y or N, or not be coded (blank).
Action: Correct the zIIP value coded on the LOCAL statement of the TP Configuration File member.
CXTPCFG047S Values on ENABLE record must specify Y or N
Meaning: The values coded for an ENABLE statement within the TP Configuration File must specify a value of Y or N.
Action: Correct the ENABLE values coded on the that statement within the TP Configuration File member.
CXTPCFG050S NOTIFY must specify Y or N and a purge duration range of 0-999
Meaning: The NOTIFY statement in the TP Configuration File must specify a Y or N value indicating whether job notifications are to be enabled. The purge duration value specifies how many days the job notification data can be queued up for delivery before it is deleted because of non-delivery.
Action: Specify Y or N after the NOTIFY keyword, and a value between 0 and 999 for the purge duration. The purge duration is in number of days. A purge duration of zero indicates no purging will occur for non-deliverable messages.
CXTPCFG054I CXTPMSGS must specify FULL, QUIET, or NONE.
Meaning: The CXTPMSGS statement within the TP Configuration File member must be coded with one of the options being FULL, QUIET, or NONE, but an unexpected value was found.
Action: Correct the CXTPMSGS statement by specifying the correct option.
CXTPCFG058S DSNHLQ must contain characters A-Z, 0-9, #,@,$ only
Meaning: A high level qualifier was specified via the DSNHLQ statement in the TP Configuration File. The qualifier is invalid and does not consist of the valid characters for specifying dataset names.
Action: Correct the DSNHLQ parameter to specify only the characters consisting of A through Z, 0 through 9, #, @, or
$
CXTPCFG059S DSNHLQ must start with a non-numeric character
Meaning: A high level qualifier was specified via the DSNHLQ statement in the TP Configuration File. The qualifier is invalid and does not begin with a non-numeric character as required for specifying dataset names.
Action: Correct the DSNHLQ parameter to specify only the characters consisting of A through Z, or #, @, or $ as the first character of the qualifier.
Compuware Workbench Messages and Codes
I-73
CXTPCFG060S INACTIVITY time out value range must be 0-32767
Meaning: The time out minutes value for the INACTIVITY statement is the first numeric parameter of two parameters on this statement. This value must be in a range of zero to 32767. A zero value indicates that no connections are to be terminated due to inactivity.
Action: Correct the first INACTIVITY parameter to specify a time out value in minutes in the range 0-32767.
CXTPCFG063S NOTIFYONLY must specify one of ALL or LOCAL
Meaning: The NOTIFYONLY statement parameter is incorrectly specified. The parameter values must be specified as
ALL or LOCAL.
Action: Correct the NOTIFYONLY parameter to specify ALL or LOCAL.
Explanation: CXTPFXV056S FXSERVER module could not be loaded;
CXTPCIC039I IP=ip address, Port=port, TCPNAME=tcp/ip stack name
Meaning: An Xpediter/Eclipse request to launch a CICS debugging session is showing the IP address and port number of the desired CICS. The TCP/IP stack name being used is displayed. The stack name should be the TCPNAME value specified in the HCI configuration's HCICNAMB macro.
Action: None. The IP address displayed in the message must be the same as the z/OS system that the CICS region is executing, or the connection will not be successful.
CXTPCIC040I tranid RS=xx, CLID=cics client id
Meaning: An Xpediter/Eclipse request to launch a CICS debugging session is showing the CICS transaction ID
the CICS client ID information from TCP/IP. This information is only for diagnostic purposes when connection failures occur.
Action: None.
CXTPCIC041I Launch RC=xx FDBK=xxx Reason=xx
Meaning: An Xpediter/Eclipse request to launch a CICS or TSO based debugging session is showing the return code and reason codes, if any, issued by the launch sequence. The FDBK and Reason values are the RC and Reason values
connection failures occur.
Explanation: Action: None.
CXTPFARE036W This HCI is not at the required maintenance level to support
CXTPFARE037W debugging with Xpediter/Eclipse.
Meaning: A diagnostic aid message that indicates the HCI hosting the CSS TP is not at the correct maintenance level to allow debugging with Xpediter/Eclipse.
Action: Ensure the latest Compuware maintenance is applied to HCI and CSS. Then restart the HCI and retry the debugging session.
CXTPFARE038W debugging with Host Explorer.
Meaning: A diagnostic aid message that indicates the HCI hosting the CSS TP is not at the correct maintenance level to allow operation with all parts of Host Explorer.
Action: Ensure the latest Compuware maintenance is applied to HCI and CSS. Then restart the HCI and retry the connection.
CXTPFXV057S File-AID SXVJAUTH dataset missing from STEPLIB DD
Meaning: A load failed for the module FXSERVER. This usually means that the File-AID common authorized library is not in the STEPLIB DD concatenation of the TP started-task procedure named by the STASK statement in the TP
Configuration File. These messages appear in the job log of the started-task.
Action: If File-AID Data Editor is to be used by Compuware Workbench, specify the File-AID dataset's as specified in the sample procedure member CXSS0000 in COMPWARE.MLCXnnn.SLCXCNTL.
If File-AID Data Editor is not to be used, this error can be ignored; it does not affect Compuware Workbench operation.
FDBK code 793 Reason=08060004 is issued along with these messages.
I-74
Compuware Workbench Installation Guide
CXTPFXV056S FXSERVER module could not be loaded;
CXTPFXV057S File-AID SXVJAUTH dataset missing from STEPLIB DD
Meaning: A load failed for the module FXSERVER. This usually means that the File-AID common authorized library is not in the STEPLIB DD concatenation of the TP started-task procedure named by the STASK statement in the TP
Configuration File. These messages appear in the job log of the started-task.
Action: If File-AID Data Editor is to be used by Compuware Workbench, specify the File-AID dataset's as specified in the sample procedure member CXSS0000 in COMPWARE.MLCXnnn.SLCXCNTL.
If File-AID Data Editor is not to be used, this error can be ignored; it does not affect Compuware Workbench operation.
FDBK code 793 Reason=08060004 is issued along with these messages.
CXTPMAI007I Term RC=% FDBK=% Reason=% z=% mms
Meaning: A CSS TP subtask has terminated. The last return code and reason code processed while the task was executing is shown in the FDBK= and Reason= fields. The z= field shows the amount of zIIP processing time consumed by the TP subtask during execution, in microseconds (if zIIP processing is enabled, otherwise this value is 0).
indicative only that an error occurred, and does not contain a useful value. Use only the FDBK and Reason values when looking up the error in the return codes documentation (FDBK is RC, and Reason is Reason).
CXTPMAI008I SLSE Status=xxxxxxxx CPIC-RC=yy
Meaning: A TP user is attempting to logon, but the logon attempt could not be verified. The status codes (in hex) are:
Meaning
3
4
5
1
2
Status Code
Dec Hex
00000001
00000002
00000003
00000004
00000005
Password not correct.
Password expired.
New password invalid.
User ID expired.
User ID not recognized.
8
9
6
7
00000006
00000007
00000008
00000009
User ID revoked.
Group not recognized.
User ID not valid for group.
User ID revoked from group.
10 0000000A Unspecified error returned from HCI CW_SLSE.
Action: Retry the logon attempt or contact your on site security administrator. For reason code 0000000A, contact
Compuware Customer Support and provide the reason code and CPIC-RC value in the message.
CXTPMAI009I Init tpname Hxxxxxxxx
Meaning: A CSS TP has been initiated. This message is issued instantly upon contact of the HCI by a client user. No data has yet been received or sent, this only indicates contact has occurred. The name of the TP is displayed as well as the TCB address of the new subtask in the Hxxxxxxx field.
Action: None.
CXTPMAI010S XML tag error X''xx'', tag=<tttt>
Meaning: A message was received from the client connection but during processing of the message an XML parsing error was encountered.
Action: This error can sometimes be encountered if a connection was dropped and reestablished. But if the error persists or occurs repeatedly when a client user is attempting to perform a valid function, contact Compuware
Customer Support. This error is usually identified in Host Explorer as RC=160, Reason=xx where the reason code is the same one in the message above.
Compuware Workbench Messages and Codes
I-75
CXTPMAI013I Req = code function
Meaning: A diagnostic aid message that indicates the current function being requested by a client user. The code is the function code output by the XML parser and the function value is high level name of the function to be performed.
This message is only informational.
CXTPMAI043S The HCI configuration HCICNAMB macro does not specify HPNS=CURR
Meaning: The HCI hosting the CSS TP has either a configuration parameter mismatch or the HCI is not up to date with maintenance. The TP will not operate correctly.
Action: Ensure that the HCI configuration's HCICNAMB macro has the HPNS= parameter specifying CURR and that HCI
PTF HCA0031 is applied. After applying the PTF, you must ensure that you reassemble the HCI configuration macros using the SYS1.SMPMTS dataset in the assembly's SYSLIB DD statement concatenation. The PTF changes an HCI macro, and in order to pick up the change, the SMPMTS library must be used.
CXTPSMC048I EMCS Console tpname active
CXTPSMC048I EMCS Console tpname inactive
Meaning: The extended MCS console for the TP has become active or inactive. This message is only informational.
These messages may be accompanied by system messages IEA630I or IEA631I.
Action: None.
CXTPSMC049S EMCS console failed initialization, RC/RS=rr/ss
Meaning: The extended MCS console for the TP has failed its initialization. Job notification messages cannot be recorded.
Action: This error may be corrected by restarting HCI. However, if the error persists, contact Compuware Customer
Support for assistance. The RC/RS values are the return and reason codes from the MCSOPER macro. This macro is documented in the z/OS MVS Authorized Assembler Services Reference SA22-7609. Refer to the MCSOPER macro.
CXTPSMC051S EMCS console message retrieval failed, RC/RS=rr/ss
Meaning: The extended MCS console for the TP was unable to continue searching for job notification messages.
Action: This error may be corrected by stopping the TP's EMCS console via the TPAdmin utility and then restarting it, or by restarting HCI. However, if the error persists, contact Compuware Customer Support for assistance. The RC/RS values are the return and reason codes from the MCSOPMSG macro. This macro is documented in the z/OS MVS
Authorized Assembler Services Reference SA22-7609. Refer to the MCSOPMSG macro.
CXTPSTA011S Abend abend-code
Meaning: During TP subtask execution, an abend was encountered. An abend dump is produced and is available in the HCI sysout with a ddname of TPnnnn where nnnn is the task number of this TP identified in the message.
Action: Most abends can be ignored unless they persist. Contact Compuware Customer Support if necessary.
CXTPSTA012I Hello from ip-address userid
Meaning: The client user was successfully logged on and the TP subtask is executing under the security profile for the userid indicated in the message. In some cases a userid value might not be shown; in this instance (such as a CICS debugging session launch by Xpediter/Eclipse), the security profile will be later established by CICS.
Action: None.
CXTPTCT062I TP control task active
CXTPTCT062I TP control task has ended
Meaning: These messages simply indicate that the TP control task has started or has ended. They will be issued when the first TP starts up, and when the HCI is shut down.
Action: None.
CXTPVTA055S TP is not running APF-authorized
Meaning: The CSS TP requires APF-authorization to perform its functions. APF-authorization is a documented requirement.
I-76
Compuware Workbench Installation Guide
Action: Please ensure that the COMPWARE.MLCXnnn.SLCXAUTH library is properly APF-authorized, and that the other libraries in the associated STEPLIB concatenation are also APF-authorized so as not to lose APF-authorization for all datasets.
CXTPVTA014S Open VTAM ACB failure - ACBERROR=X''xx', APPLID=aaaaaaaa
Meaning: During an Xpediter/Eclipse interactive TSO debugging session launch, the VTAM ACB could not be opened.
This is accompanied by RC=164,Reason=XX, which is the ACB ERROR field value.
Action: Probable specification error of VTAM APPL definitions. Several possible causes exist:
"APPL definition not defined
"APPL not specified in the TP configuration file
"APPL in use by another application
"APPL requires a password (no APPL password support existing in Xpediter/Eclipse)
"APPL access restricted by local security rules
Look up the ACBERROR code in the reference below to determine the cause. If the cause cannot be corrected locally, contact Compuware Customer Support and provide the reason code. Common reason codes and their meanings:
14 - Insufficient storage to open the ACB
24 - User is not authorized to use the APPL
52 - VTAM is shutting down
58 - The APPL is already in use by another program or user
5A - The APPL was not defined to VTAM
Reference: IBM’s z/OS Communications Server SNA Programming (see Chapter 13 "Conventions and Descriptions of
VTAM macroinstructions"). After the description of the OPEN macro a list of possible return codes is listed. The
ACBERROR code xx is the OPEN return code.
CXTPVTA015S RPL error - R15=xx,R0=xx,FDBK2=xx,O=xx,C=xx,N=xx
Meaning: During an Xpediter/Eclipse debugging session with TSO, a communications error occurred between the TP and VTAM.
Action: This is an internal error. Contact Compuware Customer Support and provide the reason code. See also
CXTPVTA041I Launch RC=xx FDBK=xxx Reason=xx
Meaning: An Xpediter/Eclipse request to launch a CICS or TSO based debugging session is showing the return code
Codes” on page I-1. This information is only for diagnostic purposes when connection failures occur.
Action: None.
CXTPVTA042I TSO=tttttttt APPL=aaaaaaaa PROC=pppppppp SIZE=ssss
Meaning: An Xpediter/Eclipse request to launch a TSO based debugging session is showing the TSO APPLID specified in the TP Configuration File, the selected user APPLID also from the APPL list in the TP Configuration File, the TSO JCL procedure and region size specified by the Xpediter/Eclipse user. This information is only for diagnostic purposes when connection failures occur.
Action: None.
CXTPVTA052I ACCOUNT=account number
Meaning: The account number used for a TSO-based debug session is displayed for diagnostic purposes. This message is purely informational and might be used if TSO-based debug sessions are not correctly starting.
Action: None.
CXTPVTA053I message text
Meaning: If an unexpected message is issued by TSO or security software during the logon process that preceeds a
TSO-based debugging session, the unexpected message text will be displayed.
Action: The message text is used to assist in diagnosis of debugging start-up failures with the assistance of
Compuware Customer Support.
Compuware Workbench Messages and Codes
I-77
CXTPVTA055S TP is not running APF-authorized
Meaning: The CSS TP requires APF-authorization to perform its functions. APF-authorization is a documented requirement.
Action: Please ensure that the COMPWARE.MLCXnnn.SLCXAUTH library is properly APF-authorized, and that the other libraries in the associated STEPLIB concatenation are also APF-authorized so as not to lose APF-authorization for all datasets.
I-78
Compuware Workbench Installation Guide
Index
A
Acrobat PDF online documentation, xv
B
Batch Interface to NEWCOPY, 8-11
C
Compuware Go customer support website, xvi
Compuware Shared Services
Compuware Workbench client
installation, 4-1 installation, 4-1
Compuware Workbench Server
CSS
D
Data Privacy roles
Global Resource Administrator, 6-9
deployment
exporting
E
Eclipse
exporting
F
File-AID Data Privacy, 1-3, 6-1
install File-AID products, 6-4
role definitions, 6-8 security, 6-8
File-AID Rules Engine
FrontLine support web site, xv
H
I
APF-authorized load library, 3-1
configure
connection, 5-1 host configuration, 5-1
Hiperstation requirements, 10-1, 11-1
Host Communication Interface (HCI), 3-1
installation considerations, 3-1
importing
non-Compuware
projects, C-6 projects, C-5–C-6 previous releases, C-6
installation
client
I-1
I-2
Compuware Workbench Installation Guide
J
L
load library
M
Mainframe TP
managing security
migration
File-AID
migration from previous versions, C-1
N
NEWCOPY, Batch Interface, 8-11
O
overview
Compuware Workbench
P
R
return codes
S
sample library
configure
SlickEdit
start
Statements
stop
swap
system requirements
T
TCP/IP
U
Update site
W
workspace
X
support for
IMS, 8-1 stored procedures, 8-1
I-3
I-4
Compuware Workbench Installation Guide
Pobierz