Paradise High Power Phase Combined SSPA Systems

Paradise High Power Phase Combined SSPA Systems
Phase Combined Systems Outdoor SSPA Packages
100W Ku-Band 1:2 Phase Combined SSPA System with FPRC-1200 Controller
1 kW C-Band, 1:1 Phase Combined
High Power Outdoor SSPA System
FEATURES
125W Ku-Band 1:1 Phase Combined SSPB System with FPRC-1100 Controller
and RCP2-1100 Controller for L-Band redundancy
DESCRIPTION Teledyne Paradise Datacom’s family of outdoor packaged,
phase combined SSPA systems provide the highest degree of redundancy and system reliability. 1:1 Phase Combined Systems are an economical solution to
providing high output power capability with soft-fail redundancy.
1:2 Phase Combined Systems can provide full output power
redundancy to mission critical applications which cannot
tolerate any decrease in output power capability.
Both 1:1 and 1:2 Phase Combined Systems utilize a signal box
through which all RF and L-band input signals are distributed.
This ensures that any reference signal is modulated to each
amplifier at the same frequency, and that the phase adjustment
is optimized.
x Extremely High Power
Density:
1.2 kW C-Band;
1.2 kW S-Band;
600 W X-Band;
500 W Ku-Band
x Universal Power Factor
Corrected Power Supply
x System Output Power
Monitor
OPTIONS
x
x
x
Reflected Power Monitor
L-Band Input operation
SSPA and Controller
Remote Panels
x Auxiliary / Maintenance
Output Switch
x Cold Standby Amplifier
Operation for Prime Power
Savings
x Custom Configurations
Phase Combined Systems
Outdoor SSPA Packages
1:1 Phase Combined / Redundant System
The 1:1 Fixed Phase Combined Redundant System is a popular system architecture that
enables two Solid State Power Amplifiers to operate as a normal 1:1 redundant system or a
phase combined system. The basic system topology is very similar to a 1:1 redundant system
and is shown in the block diagram. An additional switch is included which allows either
amplifier to be individually connected to the antenna or connect both amplifiers to a
waveguide combiner.
Amp 1
RF Input
RF Output
Amp 2
1:1 Phase Combined System Simplified Block Diagram
1:2 Phase Combined / Redundant System
The 1:2 Phase Combined Redundant System is a system architecture that enables Solid
State Power Amplifiers to achieve higher output power levels while building in a level of
redundancy. The basic system topology is similar to a 1:2 redundant system shown in the
block diagram below. Amplifiers #1 and #3 are normally online. The outputs of #1 and #3 are
directed by the waveguide switches into a low loss power combiner. In the event of a failure
of either on line amplifier, the standby amplifier, #2, can be switched in place of either #1 or
#3 and the system maintains full output power.
Amp 1
RF Input
Amp 2
RF Output
Standby
Amp 3
1:2 Phase Combined System Simplified Block Diagram
2 OF 9
203582 REV X ECO 16739
Phase Combined Systems Outdoor SSPA Packages
Outdoor Systems are configured with Teledyne Paradise Datacom’s
popular High Power Outdoor or Compact Outdoor SSPA packages
High Power Outdoor Enclosure
Output Power Levels
S-Band: 400W - 600W
C-Band: 400W - 600W
X-Band: 350W - 500W
Ku-Band: 200W - 250W
Compact Outdoor SSPA
Output Power Levels
S-Band: 50W - 300W
C-Band: 30W - 300W
X-Band: 25W - 250W
Ku-Band: 10W - 150W
System Output Power Capacity
Due to the output waveguide and switches, there is always some residual loss in the output of
phase combined HPA systems. This results in slightly less than the ideal 3dB power addition
to the output power of a single HPA unit.
On 1:1 phase combined systems, the typical additive output power is 2.70 dB above the
output power of a single HPA. On 1:2 phase combined systems, the typical additive output
power is 2.50 dB above the output power of a single HPA.
For example, a 125W Ku-Band Compact Outdoor SSPA in a 1:1 phase combined system
would have the following output power:
Single Compact Outdoor HPA: P1dB = 50.0 dBm; Psat = 51.0 dBm
1:1 phase combined system:
P1dB = 52.7 dBm; Psat = 53.7 dBm
3 OF 9
203582 REV X ECO 16739
Phase Combined Systems Outdoor SSPA Packages
L-Band Operation
Teledyne Paradise Datacom Phase Combined HPA Systems can be configured for L-Band
Input operation. For optimum RF phase combining over the entire bandwidth of a
communication amplifier, the frequency translation part of the system must be separated from
the phase combining loop. Therefore, systems with L-Band input are configured with a
separate 1:1 system of L-Band Block Up Converters that feed the 1:1 or 1:2 Phase Combined
HPA system. If L-Band redundancy is not required, the system can be configured with a single
thread L-Band Block Up Converter.
1:1 / PHASE COMBINED HPA SYSTEM
2
SW1
3
1
BUC REDUNDANT SYSTEM
4
Out
BUC 1
1
SW2
2
4
BUC 2
3
85-265 Vac
47-63 Hz
100W
180 - 265 Vac
47-63 Hz
2400W
Power Factor > .9
180 - 265 Vac
47-63 Hz
2400W
Power Factor > .9
85-265 Vac
47-63 Hz
100W
The Block Up Converter system is housed in a weather-proof enclosure (shown below) and
controlled by an indoor RCP2-1100 Redundant Controller. The Up Converters can be
configured with internal or external reference oscillators. The Teledyne Paradise Datacom
ZBUCTM converter architecture allows a converter that is fitted with an internal reference
oscillator to automatically detect and switch to an externally applied 10 MHz reference signal.
4 OF 9
203582 REV X ECO 16739
Phase Combined Systems Outdoor SSPA Packages
L-Band Operation
The addition of a ZBUCTM converter to an Oudoor SSPA typically increases the gain by 2-4
dB. The advantages of ZBUC technology include:
x A ZBUC converter can detect and switch to an extenally supplied reference.
x Optional internal high stability (10MHz) reference.
x A ZBUC converter can lock to an externally supplied reference of 5, 10, 20, 25, or 50 MHz
without modification.
x A ZBUC converter can accept a wide range of external reference power (-10d to +5 dBm)
x A ZBUC converter can accept FSK monitor and control signal via the IFL for complete
amplifer remote control.
Available Frequency Plans
Band
Frequency Band
IF Input
LO Frequency
RF Output
Gain Change
C
Standard C-Band
950 - 1525 MHz
4.900 GHz
5.850 - 6.425 GHz
0-4 dB
C
Extended C-Band
950 - 1825 MHz
4.900 GHz
5.850 - 6.725 GHz
0-4 dB
C
Palapa Band
950 - 1250 MHz
5.475 GHz
6.425 - 6.725 GHz
0-4 dB
C
Insat Band
950 - 1250 MHz
5.775 GHz
6.725 - 7.025 GHz
0-4 dB
C
Extended C-Band 2
950 - 1675 MHz
4.800 GHz
5.750 - 6.475 GHz
0-4 dB
X
Standard X-Band
950 - 1450 MHz
6.950 GHz
7.900 - 8.400 GHz
0-2 dB
Ku
Standard Ku-Band
950 - 1450 MHz
13.050 GHz
14.00 - 14.50 GHz
0-2 dB
Ku
Extended Ku-Band
950 - 1700 MHz
12.800 GHz
13.75 - 14.50 GHz
0-2 dB
Electrical Specifications for Outdoor SSPA with ZBUC converter PARAMETER
Gain
Gain Flatness
Gain Slope
Gain Adjusted Range
Gain Stability
Phase Noise
Spurious
Noise Figure
Input VSWR
Internal Reference Option
5 OF 9
NOTES
LIMITS
UNITS
Nominal setting
full band (C-,X-,Ku-bands)
per 40 MHz (C-,X-,Ku-bands)
75
r2.0
r0.5
20
60 - 80
57 - 77
r1.5
dB
dB
dB/40 MHz
dB
dB
dB
dB
Typical C-Band Adj. Range
Typical Ku-Band Adj. Range
-40 to +60 °C
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Absolute max.
-30
-60
-70
-80
-90
-90
C-band (typ.)
-60
-80
-80
-85
-120
-125
X-band (typ.)
-60
-75
-75
-100
-110
-122
Ku-band (typ.)
-50
-65
-72
-90
-110
-120
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
In-Band Signal Related (C-/Ku-Band)
(Extended C-Band)
Close to Carrier Spurious (< 20 MHz)
Local Oscillator
-50
-40
-50
-30
dBc
dBc
dBc
dBm
At 75 dB gain setting
20
dB
L-Band
1.5 : 1
Reference accuracy @ 25 °C
Reference Stability over Temperature (-40 to +40 °C)
±1 • 10-8
±1 • 10-9
203582 REV X ECO 16739
Phase Combined Systems Outdoor SSPA Packages
System Controllers FPRC-1100 1:1 Phase Combined System Controller FPRC-1200 1:2 Phase Combined System Controller
The FPRC-1X00 is the heart of the Redundant SSPA System. It provides an extremely user
friendly interface for complete monitor and control of the high power amplifiers. The front
panel mimic display shows the on-line amplifiers and the switch positions. Fault lights are
provided for easy indication of system status.
All FPRC-1X00 monitor and control is available locally at the front panel LCD display, as well
as remotely by the RS232 , RS485, or Ethernet interface ports. Audible alarms and a full com­
pliment of parallel I/O signal are available at the rear panel of the FPRC-1X00.
The FPRC-1X00 System Controller allows the Phase Combined System of amplifiers to be
controlled as if it were a single SSPA. The FPRC is the single point of interface for either
local, front panel, or remote control. System monitor and control capability include gain
adjustment, output power monitoring (dBm or Watts), and alarms.
The FPRC-1X00 is a 1RU indoor control unit that contains its own internal redundant
components including fully redundant power supplies.
Note: Systems can be configured without the use of a system controller. Consult the factory for operation of phase combined systems without
a system controller.
6 OF 9
203582 REV X ECO 16739
Phase Combined Systems Outdoor SSPA Packages
General System Specifications
PARAMETER
Gain
Gain Flatness
Gain Slope
Gain Variation vs. Temperature
Gain Adjustment
Intermodulation Distortion
AM/PM Conversion
Spurious
Harmonics
Input/Output VSWR
Noise Figure
Group Delay
(per 40 MHz segment)
Transmit Band Noise
Output Power Density
Receive Band Noise
Output Power Density
Residual AM Noise
Phase Noise
NOTES
LIMITS
UNITS
minimum
minimum (units with L-Band input)
full band (all except Extended C-Band)
Extended C-Band units
per 40 MHz
per 10 MHz
-40 to +60°C
0.1 dB resolution
3dB back off relative to P1dB
(@ rated P1dB)
(@P1dB-3dB)
(@ rated P1dB)
(@ rated P1dB-3dB) (C-,X-,Ku-bands)
(@ rated P1dB-3dB) (S-band)
Standard band units
Extended band units
at maximum gain (C-,X-,Ku-bands)
at maximum gain (S-band)
Linear
Parabolic
Ripple
TX Band
RX Band (C- or Ku-bands)
RX Band (X-Band)
RX Band (S-Band)
S-Band, with optional filter
S-Band, without optional filter
0 - 10 KHz
10 KHz - 500 KHz
500 KHz - 1 MHz
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
70
67
±1.0
±1.5
±0.3
±0.2
±1.0
20
-25
3.5
1.0
-60
-50
-30
1.30:1
1.50:1
10
8
0.01
0.003
1.0
-75
-150
-100
See options
-155
-95
-45
-20 (1.25 + log F)
-80
dB
dB
dB
dB
dB/40 MHz
dB/10 MHz
dB
dB
dBc
°/dB
°/dB
dBc
dBc
dBc
dBW/4 KHz
dBW/4 KHz
dBc
dBc
dBc
-90
-100
-110
-120
-125
-130
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dB
dB
ns/MHz
ns/MHz2
ns p-p
dBW/4 KHz
dBW/4 KHz
dBW/4 KHz
Environmental
Operating Temperature
Ambient
-40 to +60
°C
condensing
100
%
integrated
Forced air
Size, High Power Outdoor
width X length X height
Size, Compact Outdoor
width X length X height
21.0 X 27.95 X 13.5
533 X 710 X 343
10.0 X 19.5 X 6.50
254 X 495 X 165
inches
mm
inches
mm
125 (57)
36 (16.4) ± 3%
44 (20.0) ± 3%
46.7 (21.1) ± 3%
54.9 (25.0) ± 3%
+1.7 (0.8)
lbs.(kg)
lbs.(kg)
lbs.(kg)
lbs.(kg)
lbs.(kg)
lbs.(kg)
Paint
White; powder coat
Relative Humidity
Cooling System
Mechanical
Weight, High Power Outdoor
Weight, Compact Outdoor
Finish
7 OF 9
Base unit (<200W S/C-bands; <100W Ku)
Base unit (•200W S/C-bands; •100W Ku)
Base unit (<200W X-Band)
Base unit (•200W X-Band)
With Internal zBUC
203582 REV X ECO 16739
Phase Combined Systems Outdoor SSPA Packages
Part Number Configuration, High Power Outdoor System HPA
2
W
Band
S - S-Band
C - C-Band
X - X-Band
K - Ku-Band
Power Level (in Watts)
S-Band
400, 500, 600
C-Band
400, 500, 600
X-Band
350, 500
Ku-Band
200, 250
Frequency Sub Band
S-Band
A - 2.020 - 2.120 GHz
B - 2.200 - 2.300 GHz
C-Band
A1 - 5.85 - 6.425 GHz
B1 - 5.85 - 6.725 GHz
C - 5.75 - 6.670 GHz
E1,2 - 6.425 - 6.725 GHz (Palapa)
F1,2 - 6.725 - 7.025 GHz (Insat)
G1 - 5.750 - 6.475 GHz
H1 - 5.715 - 5.790 GHz
J1 - 5.740 - 6.650 GHz
V1,3 - 5.85 - 6.725 GHz
X-Band
A1 - 7.90 - 8.40 GHz
B - 7.50 - 8.50 GHz
D - 7.70 - 8.40 GHz
E - 7.75 - 8.50 GHz
Ku-Band
A1 - 14.00 - 14.50 GHz
B1 - 13.75 - 14.50 GHz
Configuration Modifier
XXX = Standard
SXX = Input Sample
XVX = Reflected Power Monitor
XXR* = Receive Band Reject Filter
* S-Band only. 500W and 600W units require
an external filter.
System Configuration
E = 1:2, Input Splitter, FPRC-1200*
G = 1:1, Input Splitter, FPRC-1100*
J = 1:2, Input Splitter, Internal control
S = System (Custom)
* Standard Cable Length of 100 ft. (30m) with FPRC
Block Up Converter
B = BUC (Custom)
M = Internal Reference ZBUC
P = External Reference ZBUC
X = None
Package
W = Weather proof (NEMA)
Example - A 400W S-Band 1:2 Fixed Phase Combined
High Power Outdoor SSPA System with a FPRC-1200
controller and no block up converter is part number:
HPAS2400AWXEXXX.
1
Available with optional ZBUC.
Available in 400W and 500W power levels.
3
With 1.3:1 VSWR.
2
Specifications are subject to change without notice. X-band products may be subject to ITAR restrictions and should not be exported from the US without obtaining proper licensing from the appropriate government agencies. 8 OF 9
203582 REV X ECO 16739
Phase Combined Systems Outdoor SSPA Packages
Part Number Configuration, Compact Outdoor Systems C
HPA
Band
S - S-Band
C - C-Band
X - X-Band
K - Ku-Band
Configuration Modifier
XXX
KXX1
XMX
XRX2
XSX2
Generation
2 - All other Sub-Bands and Power Levels
4 - 150W Ku-Band only
=
=
=
=
=
XTX3 =
XUX3 =
Power Level (in Watts)
XXA
=
S-Band
050, 100, 200 or 300
XXD =
XXF =
C-Band
030, 040, 050, 075, 100, 140, 200, 250 or 300
X-Band
025, 030, 060, 075, 100, 140, 200, or 250
Ku-Band
010, 020, 025, 035, 040, 050, 070, 100, 125 or
150
Frequency Sub Band
S-Band
A - 2.020 - 2.120 GHz
B - 2.200 - 2.300 GHz
C-Band
A1 - 5.85 - 6.425 GHz
B1 - 5.85 - 6.725 GHz
C - 5.75 - 6.670 GHz
E1 - 6.425 - 6.725 GHz (Palapa)
F1 - 6.725 - 7.025 GHz (Insat)
G1 - 5.750 - 6.475 GHz
H1 - 5.715 - 5.790 GHz
J1 - 5.740 - 6.650 GHz
V1,2 - 5.85 - 6.725 GHz
X-Band
A1 - 7.90 - 8.40 GHz
B - 7.50 - 8.50 GHz
D - 7.70 - 8.40 GHz
E - 7.75 - 8.50 GHz
Ku-Band
A1 - 14.00 - 14.50 GHz
B1 - 13.75 - 14.50 GHz
1
2
Available with optional ZBUC.
With 1.3:1 VSWR.
Standard
110 VAC Option
MS-Connector Covers
Receive Band Reject Filter
MS-Connector Covers &
Receive Band Reject Filter
Transmit Band Filter
MS-Connector Covers &
Transmit Band Filter
Side-mount AC Input,
Location ‘A’
48 VDC Input
Side-mount 48V Input,
Location ‘A’
1
Available in C- and X-Band models •140W
and Ku-band models •100W.
2
S-Band only.
3
X-Band only.
System Configuration
E = 1:2, Input Splitter, FPRC-12001
G = 1:1, Input Splitter, FPRC-11001
J = 1:2, Input Splitter, Internal control
S = System (Custom)
1
Standard Cable Length of 100 ft. (30m) with FPRC
Block Up Converter
B = BUC (Custom)
M = Internal Reference ZBUC
P = External Reference ZBUC
X = None
Package
C = Standard Compact Outdoor
Example - A 1:1 phase combined standard frequency 70W KuBand Compact Outdoor SSPA system with input splitter and in­
ternal control with an external reference BUC is part number:
HPAK2070ACBPXXX.
Specifications are subject to change without notice. X-band products may be subject to ITAR restrictions and should not be exported from the US without obtaining proper licensing from the appropriate government agencies. 9 OF 9
203582 REV X ECO 16739