Whirlpool | 4373526 | User's Manual | Whirlpool 4373526 User's Manual

Part No. 4373526
IMPORTANT:
Read and save
these instructions.
IMPORTANT:
Installer: Leave Installation Instructions
with the homeowner.
Homeowner:
Keep Installation Instructions
for future reference.
Save Installation Instructions for local
electrical
inspector’s use,
Pure Delivery
Water Systerh
Before you start...
Check location where water pump will
be installed. Proper installation is your
responsibility. Make sure you have
everything
necessary for correct
installation,
The serial/rating
information
is located
on the base of pump.
Important: Observe all governing
codes
and ordinances.
Earthed electrical
outlet is required. See
Electrical requirements,
Water connections
to pump Do Not
require sealing compounds
to prevent
leaking.
Electrical Shock Hazard
It is the customer’s responsibility:
To contact a qualified electrical
installer.
To assure that the electrical
installation is adequate
and in
conformance
with National Electrical
Codes, and all local codes and
ordinances.
Failure to do so could result in fire,
electrical
shock or other personal
injury.
Personal Injury Hazard
Do Not use water pump to pump
any other liquids. Use only for bottled
water.
. Clean system after extended
periods of non-use.
Failure to follow these instructions may
result in personal injury.
l
l
l
Property/Product
Damage
Do Not store water bottle and water
pump in an area where temperatures
fall below O°C(320F).
Failure to follow these instructions may
result in property or product damage.
l
Tools needed for
installation:
6
knife or
tubing
cutter
a
Parts sup lied
for hstal Patgon:
.
water bottle
tubing%
water
bottle
bottle cap
4.“83
to rffrigerator
“$
“,
a
l/4” outside
diameter
tubing
P
this end is
3/S” outside
diameter
tubing
-.z#t.
Parts not supplied
for installatiron:
I
l
switch
fittings to connect
l/4” 0. D. tubing to
refrigerator
inlet
Electrical
requirements
. Electrical earth is required on this
appliance.
. If cold water pipe is interrupted
by
plastic, non-metallic
gaskets or other
insulating materials, Do Not use for
earthing.
. Do Not earth to a gas pipe.
Do Not modify the power supply cord
plug. If it does not fit the outlet, have a
proper outlet installed by a qualified
electrician.
Do Not have a fuse in the neutral or
earthing circuit. A fuse in the neutral or
earthing circuit could result in
electrical shock.
Do Not use an extension cord with this
appliance.
l
l
l
Panel A
If additional
tubing is
required, you will need
tubing connector,
Pat-l No.
4319153 and l/4” O.D.
tubing, Part No. 4319151.
Schuko earthing-type
t%
wall receptacle
““a,
Electrical
If codes permit and a separate
wire is used, it is recommended
qualified electrician
determine
earthing path is adequate.
l
earthing
that a
that the
Shock Hazard
l
l
Check with a qualified electrician
if you
are in doubt as to whether the appliance
is properly earthed.
This appliance
is equipped
with a power
supply cord having a 3-prong earthing
plug. To minimize possible shock hazard,
the cord must be plugged into a mating
3-prong earthing-type
wall receptacle,
earthed in conformance
with National
Electrical Codes, and all local codes and
ordinances.
See Figures 1 and 2. If a
mating wall receptacle
is not available,
it
is the personal responsibility
and
obligation
of the customer to have a
properly earthed 3-prong wall receptacle
installed by a qualified electrician.
Failure to follow these instructions
result in a serious injury or death.
Schuko
earthing
plug
Ngliqdg
*’ ”
Power supply
uu
Figure 1
3-prong earthing-type
wall receptacle
\
-%
3-prong
earthing
could
A fused electrical supply is required.
(Time-delay fuse or circuit breaker is
recommended.)
It is recommended
that a separate circuit serving only this
appliance
by provided.
supply
cord
Figure 2
cord
Now start...
With pump in room where
will be installed.
1
Determine where you wish to
locate water pump and water
bottle. The water bottle and water
pump should be installed on the same
level.
The water bottle and water pump must
be located close together since the
tubing connecting
the pump to the
water bottle is 1.8m (6 feet) long. Use
existing tubing between water pump
and water bottle. Do Not cut this tubing
or add tubing between pump and water
bottle. Do Not remove clamp on end of
tubing that connects inner tubing to
outer tubing.
l
The water pump operates
automatically
when dispenser
operated.
When the dispenser
released, the water pump
automatically
stops operating.
.
Suggested
l
Information
it
5
Route the tubing to the
refrigerator.
Cut tubing to
length needed.
’
is
is
When water bottle empties
during use: Pressurized air is expelled
through
empty.
1
’
dispenser
when water
Stop dispensing
refrigerator.
bottle
is
from the
locations:
Under the sink .
Cabinet next to refrigerator.
6
Plug power supply cord into
’ earthed, electrical outlet. Press
the pump switch to the “I” position.
2
3.
n
bottle
bottle
Determine where you will need
. to run water lines and the
length of tubing that will be
needed. If more tubing is needed than
what is supplied, tubing (Part No.
4319151) and tubing connectors
(Part
No. 4319153) can be obtained
from
your dealer or authorized parts
distributor.
2
Press the switch on the
water pump to the “0”
position.
Remove bottle cap from water
bottle. Replace empty water
Attach bottle cap to full water
connector
tubing
collet
7
Run enough water through
refrigerator to fill a glass or other
container.
Check all connections
for
leaks.
If a connection
leaks, push in collet and
remove tubing. Cut off 1.3cm (l/2”) of
tubing and reinsert into connector.
3
Attach bottle cap to water
’ bottle. Push the tubing into the
water bottle until the end of the tubing
reaches the bottom of the bottle. Do
Not remove clamp from end of tubing.
Press the switch on the water
pump to the “I” position.
,
If unit is connected
ONLY to a
refrigerator icemaker, the icemaker will
have to call for water before pump can
be checked for leaks.
If water bottle empties while
the pump will run for
unattended,
2-l /2 minutes and then automatically
shut off.
1.
2.
Press the switch on the water
pump to the “0” position.
?emove bottle cap from water
mottle. Replace empty water
bottle. Attach bottle cap to full water
bottle.
3.
Press the switch on the water
pump to the “I” position.
If water system is exposed to
temperatures
below 0°C (32’F),
the system must be drained.
Remove tube from bottle. Open all
outlets and run pump to inject air
through all outlets.
Cleaning
and sanitizing
system:
System should be cleaned after
extended
periods of non-use.
1
4
,
Insert one end of the outlet
tubing into connector
located
on outside of pump as far as it will go, If
tubing needs to be adjusted, push
connector
in and pull tubing out.
Panel B
n
Add one-half teaspoon of
chlorine bleach to one gallon
water.
2.
3.
Inset-t tube into solution
w-w
4,
Flush system with water
chlorine is removed.
of
and start
Open all outlets to fill system with
solution. Let stand five minutes.
until
If you need
semice...
Troubleshooting
Solution
Cause
Problem
Water pump cycles
on and off:
Water leaks at one or more
outlet connectors.
Check all fittings and water
pump connections
for
leaks.
l
Push in connector
and
remove tubing. Cut off
1.3cm (l/2”) of tubing and
reinsert into connector.
. Do Not cut water bottle to
pump tubing.
Water pump
run:
Electrical
supplied.
Check that power supply
cord is plugged into outlet.
l Check
if circuit breaker has
tripped or if fuse has blown.
. Check to see if water bottle
is empty. Replace water
bottle according
to
instructions.
. Press switch on the water
pump to “0” position.
Then press the switch to
the“l” position to reset
motor timer.
does not
Water pump operates
continuously
until
motor timer stops
motor:
power
Water bottle
is empty.
Water bottle
is empty.
Air leak in water
to pump tubing.
Air in system.
not being
bottle
l
l
Replace water bottle
according
to instructions.
Check that tubing in water
bottle is touching bottom of
bottle. If tubing is too high, it
will take in air.
. Check that tubing is tightly
pushed in place inside
water pump connector.
l
Pure Deliver-v Water Puma Warrantv
I
Length of Warranty
Whirlpool
ONE YEAR FULL
WARRANTY
From date of purchase.
Replacement
parts and repair labor to correct defects in
materials or workmanship.
Service must be provided by an
authorized Whirlpool International
distributor or their
appointed
dealer or service company.
Whirlpool
Will Pay For:
Will Not Pay For:
A, Service calls to:
1. Correct the installation of the pump,
2. Instruct you how to use the pump.
3. Replace house fuses, circuit breakers or correct house wiring.
B. Repairs when pump is used in other than normal use.
C. Damage resulting from accident,
alteration,
misuse, abuse, improper
installation not in accordance
with local electrical codes,
Whirlpool
Panel C
does not assume any responsibility
for incidental
or consequential
installation
damages
or
Call your authorized Whirlpool
International
Distributor or their
appointed
dealer or service company.
When you call, you will need the pump
model number which is located on the
serial/rating
plate on the base of
the pump.
Part No. 4373526
0 1992 Whirlpool Corporation
Prepared
by Whirlpool
Corporation,
Benton
Harbor, MI 49022
Printed in U.S.A.