advertisement
▼
Scroll to page 2
of 3
SAB-2000: Intelligent System Alarm Board Startup Manual Getting Started Configuring the SAB-2000 SAB-2000 is pre-installed inside your system chassis. Hardware switch will be fine tuned according to your system layout. Please refer to your user manual for its’ location. With different system layout. We can configure SAB-2000 by H/W switch. Please refer to “Switch Setting” section for detailed information. For remote management function. You will need to install SUSIAccess. Then you will be able to monitor system fan speed, system temperature, CPU temperature and voltage. You can also set your own alarm standard under SUSIAccess according to your demand. For detailed information. Please refer to user guide of SUSIAccess. Specifications Hardware Specifications Alarm Notification • 1 ten-pin hardware switch to configure alarm settings • 1 SM bus interface for system and main board healthy status monitoring • Up to 4 external temperature sensors • 7 fan tachometer inputs • 1 external IPMI module connector • 1 built-in buzzer for system health status notice • Automatic smart fan control • Reserved PCB layout for gravity and humidity sensor Dimensions • Kernel module (9692S20000E): 115 mm x 55 mm LED & Beep Item Status Criteria LED Beep Normal - Normal - Redundant power module fail - Warn Keep beep Get IPMI & SUSI Command to search - Blinking Keep Warn beep Normal - Normal Data transferring - Blinking - Normal > 500 rpm Normal - CPU FAN fail < 500 rpm Warn Keep beep System fan fail < 500 rpm Blinking Keep Warn beep Normal - Normal - CPU thermal fail > 70 deg. Warn Keep beep System thermal fail (Thermistor) > 55 deg. Blinking Keep Warn beep Alarm Reset Close alarm beep 3 min Push - Other Power off when LED of Warn system fail (ATX only) fail part PWR HDD Sensor Input Specifications • Voltage Inputs: +5 VDC, -5 VDC, 5 VSB, +3.3 VDC, +12 VDC, -12 VDC • Temperature Sensors: LM75 digital temperature sensor, I2C interface, -30 ~ +125°C (-22 ~ 257°F) • Fan Speed Monitor: Up to 7 fans, 0 ~ 20000 RPM • Power Monitoring: Detect Redundant power Get IPMI & SUSI Command System Status Monitoring & Management • Real-time healthy status monitoring: Realtime system/ main board FAN speed, temperature monitor. • Remote system monitor through SUSIAccess • Alarm through on-board buzzer and LED signal Management Functions • Web-based remote configure, control and monitor • Remote reset, power down and power up. • Remote digital output signal control FAN TEMP. Note: This manual is for the SAB-2000. Part No. 2002S20000 Print in China 1st Edition Mar. 2013 - - LED color might be different in each chassis. Power Consumption • 12 V @ 5.25 A SAB-2000 Startup Manual 1 Connectors and Switch Setting Hardware Switch SW1 ~ 3 Label Function SW1 ~ 10 Hardware Switch SW1. Pin1 SW1. Pin2 SW1. Pin3 Cable Status OFF OFF OFF No Connect Disable Disable OFF OFF ON Connect Disable 1 OFF ON OFF Connect Disable 2 OFF ON ON Connect 1 1 ON OFF OFF Connect 2 1 ON OFF ON Connect 2 2 Connectors MB FAN CPU TEMP Label Function TR1 Thermistor Connector TR2 Thermistor Connector TR3 Thermistor Connector ON ON OFF Connect 3 1 TR4 Thermistor Connector ON ON ON Connect 3 2 ALMRST1 Alarm Reset Connector IPMB1 IPMI module connector SW4 ~ 6 PMBUS1 PMBUS Connector SW1.Pin4 SW1.Pin5 SW1.Pin6 LEBOARD1 LED Board Connector SYS FAN Qty OFF OFF OFF Disable SMB_3V_1 SMBus Device Connector OFF OFF ON 1 (FAN1) SMB_3V_2 SMBus Device Connector OFF ON OFF 2 (FAN1~2) BZ1 External Buzzer Connector OFF ON ON 3 (FAN1~3) HDD1 HDD LED connector ON OFF OFF 4 (FAN1~4) PSU Power Connector ON OFF ON 5 (FAN1~5) ON ON OFF 6 (FAN1~6) ON ON ON 7 (FAN1~7) SW1.Pin7 SW1.Pin8 SW1.Pin9 TEMP Qty OFF OFF OFF Disable OFF OFF ON 1 (TR1) PWR1 SMB_MB1 Main Board SMBus Connector RDUPG1 Power Good Input Connector VOLT1 Backplane VOLT1 Connector FAN1 FAN Connector FAN2 FAN Connector FAN3 FAN Connector FAN4 FAN Connector ON ON OFF 2 (TR1~2) FAN5 FAN Connector ON ON ON 3 (TR1~3) FAN6 FAN Connector ON OFF OFF 4 (TR1~4) FAN7 FAN Connector SW7 ~ 9 SW10 Note: Please connect the fan connectors in the correct sequence: If two fans are being connected. The correct method is to connect them into FAN1 and FAN2. If fans are connected out of sequence. Alarm will not function correctly. 2 SAB-2000 Startup Manual SW1.Pin10 Smart FAN OFF Enable ON Disable Board Layout TR4 TR3 Figure: Connector locations of SAB-2000 SAB-2000 Startup Manual 3
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project