SAB-2000 is pre-installed inside your system chassis. Hardware switch will be fine tuned according to your system layout.
Please refer to your user manual for its’ location.
With different system layout. We can configure SAB-2000 by H/W switch. Please refer to “Switch Setting” section for detailed
information.
For remote management function. You will need to install SUSIAccess. Then you will be able to monitor system fan speed,
system temperature, CPU temperature and voltage. You can also set your own alarm standard under SUSIAccess according
to your demand. For detailed information. Please refer to user guide of SUSIAccess.
Specifications
Hardware Specifications
Alarm Notification
• 1 ten-pin hardware switch to configure alarm settings
• 1 SM bus interface for system and main board healthy
status monitoring
• Up to 4 external temperature sensors
• 7 fan tachometer inputs
• 1 external IPMI module connector
• 1 built-in buzzer for system health status notice
• Automatic smart fan control
• Reserved PCB layout for gravity and humidity sensor
Dimensions
• Kernel module (9692S20000E): 115 mm x 55 mm
LED & Beep
Item
Status
Criteria LED
Beep
Normal
-
Normal
-
Redundant power
module fail
-
Warn
Keep
beep
Get IPMI & SUSI
Command to search
-
Blinking Keep
Warn beep
Normal
-
Normal
Data transferring
-
Blinking -
Normal
> 500
rpm
Normal
-
CPU FAN fail
< 500
rpm
Warn
Keep
beep
System fan fail
< 500
rpm
Blinking Keep
Warn
beep
Normal
-
Normal
-
CPU thermal fail
> 70
deg.
Warn
Keep
beep
System thermal fail
(Thermistor)
> 55
deg.
Blinking Keep
Warn
beep
Alarm
Reset
Close alarm beep
3 min
Push
-
Other
Power off when LED of
Warn
system fail (ATX only) fail part
PWR
HDD
Sensor Input Specifications
• Voltage Inputs: +5 VDC, -5 VDC, 5 VSB, +3.3 VDC, +12
VDC, -12 VDC
• Temperature Sensors: LM75 digital temperature sensor,
I2C interface, -30 ~ +125°C (-22 ~ 257°F)
• Fan Speed Monitor: Up to 7 fans, 0 ~ 20000 RPM
• Power Monitoring:
Detect Redundant power Get
IPMI & SUSI Command
System Status Monitoring & Management
• Real-time healthy status monitoring: Realtime system/
main board FAN speed, temperature monitor.
• Remote system monitor through SUSIAccess
• Alarm through on-board buzzer and LED signal
Management Functions
• Web-based remote configure, control and monitor
• Remote reset, power down and power up.
• Remote digital output signal control
FAN
TEMP.
Note:
This manual is for the SAB-2000.
Part No. 2002S20000
Print in China
1st Edition
Mar. 2013
-
-
LED color might be different in each chassis.
Power Consumption
• 12 V @ 5.25 A
SAB-2000 Startup Manual 1
Connectors and Switch Setting
Hardware Switch
SW1 ~ 3
Label
Function
SW1 ~ 10
Hardware Switch
SW1.
Pin1
SW1.
Pin2
SW1.
Pin3
Cable
Status
OFF
OFF
OFF
No Connect Disable
Disable
OFF
OFF
ON
Connect
Disable
1
OFF
ON
OFF
Connect
Disable
2
OFF
ON
ON
Connect
1
1
ON
OFF
OFF
Connect
2
1
ON
OFF
ON
Connect
2
2
Connectors
MB FAN
CPU
TEMP
Label
Function
TR1
Thermistor Connector
TR2
Thermistor Connector
TR3
Thermistor Connector
ON
ON
OFF
Connect
3
1
TR4
Thermistor Connector
ON
ON
ON
Connect
3
2
ALMRST1
Alarm Reset Connector
IPMB1
IPMI module connector
SW4 ~ 6
PMBUS1
PMBUS Connector
SW1.Pin4
SW1.Pin5
SW1.Pin6
LEBOARD1
LED Board Connector
SYS FAN
Qty
OFF
OFF
OFF
Disable
SMB_3V_1
SMBus Device Connector
OFF
OFF
ON
1 (FAN1)
SMB_3V_2
SMBus Device Connector
OFF
ON
OFF
2 (FAN1~2)
BZ1
External Buzzer Connector
OFF
ON
ON
3 (FAN1~3)
HDD1
HDD LED connector
ON
OFF
OFF
4 (FAN1~4)
PSU Power Connector
ON
OFF
ON
5 (FAN1~5)
ON
ON
OFF
6 (FAN1~6)
ON
ON
ON
7 (FAN1~7)
SW1.Pin7
SW1.Pin8
SW1.Pin9
TEMP Qty
OFF
OFF
OFF
Disable
OFF
OFF
ON
1 (TR1)
PWR1
SMB_MB1
Main Board SMBus Connector
RDUPG1
Power Good Input Connector
VOLT1
Backplane VOLT1 Connector
FAN1
FAN Connector
FAN2
FAN Connector
FAN3
FAN Connector
FAN4
FAN Connector
ON
ON
OFF
2 (TR1~2)
FAN5
FAN Connector
ON
ON
ON
3 (TR1~3)
FAN6
FAN Connector
ON
OFF
OFF
4 (TR1~4)
FAN7
FAN Connector
SW7 ~ 9
SW10
Note: Please connect the fan connectors in the correct
sequence: If two fans are being connected. The
correct method is to connect them into FAN1 and
FAN2. If fans are connected out of sequence.
Alarm will not function correctly.
2 SAB-2000 Startup Manual
SW1.Pin10
Smart FAN
OFF
Enable
ON
Disable
Board Layout
TR4
TR3
Figure: Connector locations of SAB-2000
SAB-2000 Startup Manual 3

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement