FLIR DNR400R Series PoE HD Network Video Recorder manual

Add to my manuals
14 Pages

advertisement

FLIR DNR400R Series PoE HD Network Video Recorder manual | Manualzz

NVR Installation Manual

1/31/2015

V1.0

DNR400

Table of Contents

WORKFLOW .....................................................................................................................................................................3

INSTALLATION WORKSHEET .....................................................................................................................................4

Default NVR Login ................................................................................................................................................................................ 4

NETWORK SETUP ...........................................................................................................................................................5

SMTP EMAIL SETTINGS ................................................................................................................................................7

UPnP Setup .......................................................................................................................................................................................... 8

(Non-UPnP) Router Settings ................................................................................................................................................................ 8

USER SETTINGS ...............................................................................................................................................................9

Encoding Settings............................................................................................................................................................................... 10

ALARM INPUT SETUP ................................................................................................................................................. 13

CONFIGURE I-VIEW NOW ENTRY DELAYS ........................................................................................................... 14

TEST SETTINGS ............................................................................................................................................................ 14

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 2

Workflow

1. Network Setup: Setting a Static IP, enabling external access via port forwarding a. LAN Setup: static IP address assigned by site IT staff b. Port Setup: forward ports to allow Device commands to be sent from I-View Now

2. Configure SMTP email: This will be used to communicate alerts and alarms to I-View Now. The SMTP server and

SMTP ID provided on the “Installer Data” Worksheet will be used here

3. User Setup: Change the default administrator password. I-View Now will be using this password to log into the device. I-View Now suggests using the suggested password on the “Installer Data” worksheet.

4. Recording Setup: The NVR will be set to record by schedule or by events. Event recording will only record when either a motion or alarm event is detected. Scheduled recordings occur during the scheduled time.

5. Alarm Input Setup: Here the technician will be setting up the alarm inputs on the back of the NVR to perform two actions: 1) Trigger recording on all connected cameras. And most importantly, 2) Send SMTP (email) alert to

I-View Now upon the event of an alarm.

6. Motion Detection Setup: activate video motion recording for desired cameras.

7. Configure I-View Now Entry Delay: Entry delay is configured through the I-View Now portal.

8. Test: Here you will test the individual inputs on the NVR as they are connected to your alarm panel relays or other input devices. It is recommended that you test all inputs for functionality and to ensure the proper configuration has been setup in the I-View Now portal.

9. Trouble Shooting: This section is provided to help the technician troubleshoot common problems encountered while installing NVR’s.

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 3

Installation Worksheet

The I-View Now Portal will provide an Installation Worksheet after entering the NVR make and model into the system.

This sheet will contain configuration information for the NVR’s notifications area, and provides a form to fill in details about the site setup (alarms, zone names). An example worksheet is printed below.

You will need to retrieve the IP address while on-site. Either ask the customer/IT department for the IP address, or visit http://ipalarmtools.com

while on-site for the correct address.

Default NVR Login

Plug a monitor into the VGA output on the NVR. Also, plug the mouse provided with the NVR into the front side USB port of the NVR unit. The default password is admin. Be aware that the Menu’s presented in this manual can vary slightly depending on the exact model and firmware version.

User Name: admin

Password: 12345

USB Mouse VGA Cable

VGA Port

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 4

Network Setup

After logging into the device for the first time, the first setting that should be changed is the IP address. The NVR requires a static internal IP address because one or more communication ports will have to be forwarded to it from the firewall/router on site.

RightClick “Setup” at the bottom of the screen

Click Main Menu

Login with User: admin Pass: 12345

You will be presented with the MAIN MENU Bar

From the Main Menu click on the Hammer and Screwdriver for “SETTING” and Choose “NETWORK”

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 5

Start with the TCP/IP Screen

Get an available Internal Static IP Address from the Site’s IT staff

Also ask for the default gateway

(router address) and subnet mask.

Uncheck DHCP

Enter the IP Address

Enter the Gateway Address

For the DNS server either ask the

Site’s IT staff for a preferred DNS server or just use the Google public DNS server at 8.8.8.8 and

8.8.4.4

If the default TCP port 4000 is already in use it can be changed here as well

Set Max Connections to the Maximum allowed (for example on the DNR400 the Maximum is 10)

Click save/apply to ensure no settings are lost before proceeding

Next Choose “CONNECTION”

Set the default Ports as seen in the screenshot. Please make sure these are open in the router/firewall for communication.

Click save/apply to ensure no settings are lost before proceeding

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 6

SMTP EMail Settings

This section describes how to set up SMTP (email) on the NVR to allow Alarm notifications to be sent to I-View Now.

Navigate to the “EMAIL” Setting in

Network

Make sure Enable is checked.

Enter ivnview.com for the SMTP server

Enter 9116 for the Port

For Sender, Enter the SMTP ID from the Installer’s Worksheet.

For Receiver, Enter the SMTP ID from the Installer’s Worksheet.

Yes, Sender and Receiver are the same

Change Subject to ALERT

Ensure Enable SSL is chosen

Set Event interval to 0 Minutes

Click “Test” in lower left to verify connectivity

Click Apply to Save the settings

Test Failure can occur if the SMTP Server, SMTP Port, SSL, DNS, or Firewall settings are incorrect. This Test will not verify that the Sender and Receiver are correct. It just verifies connectivity to the I-View Now SMTP Server.

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 7

UPnP Setup

If the customer’s router supports UPnP – port forwarding can be accomplished automatically.

To check UPnP availability – Choose UPnP in the Network Menu

Click on “Enable”

In status you will see “Searching Now”

If UPnP is available port mapping details will be displayed

If UPnP is available and you wish to use it, click “Apply” to Save your changes.

(Non-UPnP) Router Settings

Router settings must be examined on a case by case basis. I-View Now requires one port to be forwarded to the Device.

This can be done either through port forwarding or NAT (Network Address Translation) depending on what the installation site’s router supports. With either of these router features, any unused/unfiltered External Port can be forwarded to the TCP Port (also referred to as the video port). The other approach would be to forward external ports to the NVR using the same External Port and Internal Port. In this case, the ports must be set on the NVR through Network

Settings. Common ports used for forwarding the HTTP port are 1024, 1025, 1026, 1027 or 8080. Common ports used for forwarding the Video/TCP port are 8010, 8011, 9000, and 9010.

For any of these situations it is the External IP Address and External Port numbers that must be entered into the I-View

Now “Installer’s Portal.”

Note: Any ports used must be unblocked in any firewall devices (typically just the router).

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 8

User Settings

This section instructs the tech on how to setup a user account for customer usage. The reason for setting up a separate account is not to lock them out of the NVR, it is to prevent them from making changes to the NVR that would inhibit the

NVR’s use with I-ViewNow.

Navigate from the Main Menu and choose “Setting” under “Setting”

Click on Account

Click Add User

Enter the desired user name

Enter the desired password

Enter the password again to confirm

Select Group User

This process can be repeated for more additional users if necessary

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 9

Recording Setup

The Flir NVR records video VIA 2 different stream types. I-ViewNow utilizes the sub-stream from the NVR.

Encoding Settings

The Encoding setup determines format of the video record onto the NVR. For clips to be decoded properly the frame rate must be set to 15 FPS or less on the recording channel being utilized. I-View Now suggests setting up all recording channels in this manner to avoid any potential issues when upgrading or adding cameras to the system.

Navigate to Camera>Recording

Select Continuous for one type and Sub

Stream 1 for the other (see example)

Select Compression

Select Appropriate Channel

Set Compression H.264 for both

Set Resolution CBR for both

Set Continuous to FPS 25

Set Sub Stream 1 to FPS 5

Set Regular Stream Bit Rate to 4096

Set Extra Stream Bit rate to 224

Click Apply/Save

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 10

Set your Alarm Schedule

From the Main Menu Choose the Hammer and Screwdriver and

Click on STORAGE

Choose SCHEDULE and click on the Record Tab

Set the Appropriate Channel

Set Pre-Record to 10 Seconds

The NVR can be set to Continuous, MD (Motion Detect), Alarm and MD & Alarm. Depending upon preference, Continuous or

Motion can be chosen. Also make sure ALARM is checked.

The schedule needs to be set for all cameras and 24 hours. This can be done on the main Schedule Screen graphically by checking

ALL and Click and dragging the bar across the timeline. (below)

Or clicking on the Gear Icon and entering the time numerically for each day.

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 11

While in the same page, click on RECORD on the left hand side

This is where the separate streams are denoted for recording

Make sure Schedule Options are checked on BOTH the Main Stream and the Sub Stream.

Snapshot is disabled for all as well.

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 12

Alarm Input Setup

Alarm inputs are to be configured to send SMTP notification to I-View Now whenever an alarm event occurs. I-View Now suggests recording on all camera channels whenever an alarm event is detected.

From the Main Setup Menu click on the Hammer and Screwdriver and choose

EVENT

Click the “Alarm” Tab

Select Alarm In All or the

Appropriate Channel

Check the Enable Box

Set Type Normal Open

Set anti-dither 5

Set Latch 10

Check Send Email

Check Channels

Set Post_REC to 10

Optionally check buzzer

Checking buzzer makes the NVR

Beep when an alarm input is fired

NOTE: The DNR 400 only has 4 physical alarm input connections for the 8 and 16 channel models. This will limit the ability to Video Verify only 4 cameras. Flir and I-View Now are working on updates to allow softtriggering of cameras that will resolve this issue in the future.

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 13

Configure I-View Now Entry Delays

Entry Delays are configurable through the I-View Now Dealer Portal. Log in to configure. NOTE: Entry delay takes a physical contact. For example if the DVR has 16 cameras and one Entry delay, you will only be able to Video Verify 15 cameras.

Test Settings

Once the NVR has been properly configured and the necessary settings entered into the i-viewnow.com portal, it is a good idea to test each alarm input on the NVR by triggering the corresponding device on your alarm panel.

If relay 1 is connected to input 1 on the NVR and it is supposed to trigger when a panic button is pushed, ensure not only that the NVR has received the signal. Also ensure that the I-ViewNow.com portal has received the signal and correctly identifies the type of alarm.

© 2015 I-View Now, LLC. All Rights Reserved.

Flir DNR 400 Series Installation Guide rev 1.0 Page 14

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals