UMG 605 Harmonics Alarm management Flicker Reporting Email Memory 128 MByte UMG 605 – Power quality analysers for DIN rails Communication • Profibus (DP / V0) • Modbus (RTU, UDP, TCP, Gateway) • TCP/IP • BACnet (optional) • HTTP (configurable homepage) • FTP (file transfer) • TFTP • NTP (time synchronisation) • SMTP (email function) • DHCP • SNMP Interfaces • Ethernet • RS232 • RS485 (Modbus) • RS485 (DSUB9) for Profibus Accuracy of measurement • Energy: Class 0.5S (… / 5 A) • Current: 0.2 % • Voltage: 0.2 % Power quality • Harmonics up to the 63rd harmonic, direct / indirect • Flicker measurement • Short-term interruptions (> 20 ms) • Transient recorder (> 50 μs) • Starting currents • Unbalance • Half wave RMS recordings (up to 4.5 min.) Networks • IT, TN, TT networks • 3 and 4-phase networks • Up to 4 single-phase networks Measured data memory • 128 MByte Flash Programming language • Jasic® 2 digital inputs • Pulse input • Logic input • State monitoring • HT / LT switching 2 digital outputs • Pulse output kWh / kvarh • Switch output • Threshold value output • Logic output* *(expandable via external I/O modules) Temperature measurement • PT100, PT1000, KTY83, KTY84 Network visualisation software • GridVis®-Basic (in the scope of supply) Peak demand management (optional) • Up to 64 switch-off stages 1 UMG 605 Areas of application • Power quality monitoring • Ethernet gateway for subordinate measurement points • Analysis of electrical disturbances in the event of network problems • Report generator for various power quality standards • Control tasks e.g. depending on measured value or limit values being reached • Measured value transducer for building management systems or PLC Main features Power quality • Continuous power quality monitoring (e.g. EN 50160) • Harmonics analysis up to the 63rd harmonic, even and odd • Interharmonics • Distortion factor THD-U / THD-I • Measurement of positive, negative and zero sequence component • Flicker measurement in accordance with DIN EN 61000-4-15 • Logging and storage of transients (> 50 µs) • Recording of short-term interruptions (> 20 ms) • Monitoring start-up processes • Recorder for limit value events Fig.: GridVis®– Flicker Monitoring Power • 4 voltage and 4 current measurement inputs • Logging and digitalisation of effective values (true RMS) of currents and voltages (15 – 440 Hz) • Continuous sampling of the voltage and current measurement inputs at 20 kHz • Recording of over 2,000 measured values per measurement cycle (200 ms) • Stipulation of nominal current possible for measuring current events • Fourth current measurement input is suitable for measuring the current in the neutral or PE conductor or for measuring any potential difference between N and PE. • Large measured data memory (memory range = 5 000 000 measured values) • Simple remote polling of measured data via the device's own homepage • All interfaces can be used simultaneously • Up to 4 ports can be accessed simultaneously 2 UMG 605 Impressive reporting with GridVis® • Automatic generation and sending of power quality reports • Power quality reports per EN 50160, EN 61000-2-4, IEEE519 • Illustration of the ITI-(CBEMA) curve • Freely definable time planning for the generation of reports Modern communications architecture via Ethernet • Rapid, cost-optimised and reliable communication through integration into an existing Ethernet architecture • Integration in PLC systems and building management systems • High flexibility due to the use of open standards • Simultaneous polling of interfaces possible Fig.: Automatic reporting Ethernet-Modbus gateway • Simple integration of Modbus-RTU devices into an Ethernet architecture through the Modbus gateway function • Integration of devices with identical file formats and matching function codes possible via Modbus RTU interface Powerful alarm management • Can be programmed via the graphic programming or Jasic ® source code • All measured values can be used • Can be arbitrarily, mathematically processed • Individual forwarding via email sending, switching of digital outputs, writing to Modbus addresses etc. • Watchdog APP urther alarm management functions via GridVis® -Service •F alarm management Fig.: Alarm management, alarm list (logbook) 3 UMG 605 High-speed Modbus • Fast and reliable data exchange via RS485 interface • Speed up to 921.6 kB/s Graphical programming • Comprehensive programming options on the device, 7 programs simultaneously (PLC functionality) • Jasic® source code programming • Functional expansions far beyond pure measurement • Complete APPs from the Janitza library Fig.: Graphical programming Convenient home page and email functions • Information can be received conveniently by email and via the device homepage • Access to powerful device homepage via web browser • Online data, historical data, graphs, events and much more, is available direct from the homepage Fig.: Illustration of the online data via the device's own homepage UMG 605 Large measurement data memory • 128 MByte • 5,000,000 saved values • Recording range up to 2 years • Recording freely configurable by the user Fig.: Large measurement data memory Fig.: GridVis® Graphset with THD-U, voltage, phasor diagram and load profile (kW) 4 UMG 605 Dimension diagrams All dimensions in mm 10 mm 44 mm 35 mm 90 mm 90 mm 73 mm 50 mm 107,5 mm 76 mm 82 mm Front view Side view Typical connection An. In RS232 Dig. I/O Ethernet Option 2 3 4 5 6 7 Versorgungsspannung Auxiliary Supply Spannungsmessung Voltage measurement L 1 L2 L3 L4 N 8 9 10 11 12 13 10A (UL listed) PE N L1 L2 L3 S1 S1 S2 S1 S2 S1 S2 S2 Verbraucher Load RS485 Option Strommessung Current measurement I2 I3 I4 I1 1 RS485 5 UMG 605 Device overview and technical data UMG 605 Item number 52.16.028 Item number (UL) 52.16.227 - 52.16.229 Supply voltage AC 95 ... 240 V AC 50 ... 110 V AC 20 ... 50 V AC Supply voltage DC 135 … 340 V DC 50 … 155 V DC 20 … 70 V DC 52.16.083 52.16.083 52.16.083 L1 L2 L3 N Device options BACnet communication S1 S2 S1 S2 S1 S2 General Use in low and medium voltage networks • Accuracy voltage measurement 0.25 % Accuracy active energy (kWh, …/5 A) Class 0.5S Number of measurement points per period 400 Uninterrupted measurement • RMS - momentary value Current, voltage, frequency • Active, reactive and apparent power / total and per phase • Power factor / total and per phase • Energy measurement Active, reactive and apparent energy [L1,L2,L3, L4, ∑ L1–L3, ∑ L1–L4] • Number of tariffs 8 Recording of the mean values Voltage, current / actual and maximum • Active, reactive and apparent power / actual and maximum • Frequency / actual and maximum • Demand calculation mode (bi-metallic function) / thermal • Other measurements Operating hours measurement • Clock • Weekly timer Jasic® Power quality measurements Harmonics per order / current and voltage 1st – 63rd Harmonics per order / active and reactive power 1st – 63rd Interharmonics - current / voltage • Distortion factor THD-U in % • Distortion factor THD-I in % • Voltage unbalance • Current and voltage, positive, zero and negative sequence component • Flicker: Short-term, long-term, present • Transients 50 µs Error / event recorder function • Short-term interruptions > 20 ms Oscillogram function (waveform U and I) • Under and overvoltage recording • Measured data recording Memory (Flash) 128 MB Average, minimum, maximum values • Measured data channels 8 Alarm messages • Time stamp • Time basis average value freely user-defined RMS averaging, arithmetic • Comment: For detailed technical information please refer to the operation manual and the Modbus address list. 6 L2 L3 N I1 I2 I3 0.2 % Accuracy current measurement • = included - = not included L1 Fig.: Measurement via 3 voltage transformers in a three-phase 4-wire network with asymmetric loading UMG 605 Displays and inputs / outputs Local substation LCD display • Digital inputs 2 Digital outputs (as switch or pulse output) 2 Thermistor input (PT100, PT1000, KTY83, KTY84) UMG 605 Modbus UMG 96RM UMG 96RM Fig.: Example of a master - slave combination • Voltage and current inputs each 4 Password protection • Peak load management (optionally 64 channels) • Communication Interfaces RS485: 9.6 – 921.6 kbps (Screw-type terminal) • RS232: 9.6 – 115.2 kbps (Screw-type terminal) • Profibus DP: Up to 12 Mbps (DSUB-9 connector) • Ethernet 10/100 Base-TX (RJ-45 socket) • Protocols Modbus RTU, Modbus TCP, Modbus RTU over Ethernet • Modbus Gateway for Master-Slave configuration • Profibus DP V0 • HTTP (homepage configurable) • SMTP (email) • NTP (time synchronisation) • TFTP • FTP (File-Transfer) • SNMP • DHCP • TCP/IP • • BACnet (optional) • ICMP (Ping) • Software GridVis®-Basic*1 Online and historic graphs • Databases (Janitza DB, Derby DB); MySQL, MS SQL with higher GridVis® versions) • Manual reports (energy, power quality) • Graphical programming • Topology views • Manual read-out of the measuring devices • Graph sets • Programming / threshold values / alarm management Application programs freely programmable 7 Graphical programming • Programming via source code Jasic® • Technical data Type of measurement Constant true RMS up to the 63rd harmonic Nominal voltage, three-phase, 4-conductor (L-N, L-L) 277 / 480 V AC Nominal voltage, three-phase, 3-conductor (L-L) 480 V AC Measurement in quadrants 4 Networks TN, TT, IT Measurement in single-phase/multi-phase networks 1 ph, 2 ph, 3 ph, 4 ph and up to 4 times 1 ph Measured voltage input Overvoltage category 300 V CAT III Measured range, voltage L-N, AC (without potential transformer) 10 ... 600 Vrms Measured range, voltage L-L, AC (without potential transformer) 18 ... 1000 Vrms Resolution 0.01 V Impedance 4 MOhm / phase Frequency measuring range 15 … 440 Hz Power consumption approx. 0.1 VA Sampling frequency 20 kHz / phase Transients > 50 µs Comment: For detailed technical information please refer to the operation manual and the Modbus address list. • = included - = not included *1Optional additional functions with the packages GridVis®-Professional, GridVis®-Service and GridVis®-Ultimate. 7 UMG 605 Measured current input Rated current 1/5A Resolution 1 mA Measurement range 0.001 ... 8.5 Arms Overvoltage category 300 V CAT III Measurement surge voltage 4 kV Power consumption approx. 0.2 VA (Ri = 5 MOhm) Overload for 1 sec. 100 A (sinusoidal) Sampling frequency 20 kHz Digital inputs and outputs Number of digital inputs 2 Maximum counting frequency 20 Hz Reaction time (Jasic® program) 200 ms Input signal present 18 ... 28 V DC (typical 4 mA) Input signal not present 0 ... 5 V DC, current < 0.5 mA Number of digital outputs 2 Switching voltage max. 60 V DC, 30 V AC Switching current max. 50 mA Eff AC / DC Reaction time (Jasic® program) 200 ms Output of voltage dips 20 ms Pulse output (energy pulse) max. 20 Hz Maximum cable length up to 30 m unscreened, from 30 m screened Mechanical properties Weight 350 g Device dimensions in mm (H x W x D) 90 x 107.5 x approx. 82 Battery Type Lithium CR2032, 3 V Protection class per EN 60529 IP20 Assembly per IEC EN 60999-1 / DIN EN 50022 35 mm DIN mounting rails Connecting phase (U / I), Single core, multi-core, fine-stranded Terminal pins, core end sheath 0.08 to 2.5 mm² 1.5 mm² Environmental conditions Temperature range Operation: K55 (-10 ... +55 °C) Relative humidity Operation: 5 to 95 % (at 25 °C) Operating height 0 ... 2,000 m above sea level Degree of pollution 2 Installation position user-defined Electromagnetic compatibility Electromagnetic compatibility of electrical equipment Directive 2004/108/EC Electrical appliances for application within particular voltage limits Directive 2006/95/EC Equipment safety Safety requirements for electrical equipment for measurement, regulation, control and laboratory use – Part 1: General requirements IEC/EN 61010-1 Part 2-030: Particular requirements for testing and measuring circuits IEC/EN 61010-2-030 Noise immunity Industrial environment IEC/EN 61326-1 Electrostatic discharge IEC/EN 61000-4-2 Voltage dips IEC/EN 61000-4-11 Emissions Class A: Industrial environment IEC/EN 61326-1 RFI Field Strength 30 – 1,000 MHz IEC/CISPR11/EN 55011 Radiated interference voltage 0.15 – 30 MHz IEC/CISPR11/EN 55011 Safety Europe CE labelling USA and Canada UL variants available Firmware Firmware update Update via GridVis® software. Firmware download (free of charge) from the website: http://www.janitza.com Comment: For detailed technical information please refer to the operation manual and the Modbus address list. • = included - = not included 8 UMG 605 Digital inputs 1-2 Digital Input 1 19 S0 pulse generator + 24V 1,5k = - Digital Input 2 20 3,9V 4k 3,9V 4k 21 Fig.: Example for the connection of an S0 pulse transducer to digital input 2
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement