YORK Sunline Magnum DJ 036, DJ 048, DJ 060 Air Conditioners Техническое руководство
Below you will find brief information for Sunline Magnum DJ 036, Sunline Magnum DJ 048, Sunline Magnum DJ 060. These convertible single-package air conditioners offer a common cabinet and roof curb for 3, 4, and 5-ton sizes. Suitable for light and commercial applications, they're easily installed on various surfaces. Units feature permanently lubricated motors, field-convertible air discharge, and a Simplicity control board. Enjoy comprehensive warranties covering parts, compressor, electric heat elements, and gas-fired heat exchangers.
PDF
Download
Document
Advertisement
Advertisement
036-21687-002-A-1105 ® DESCRIPTION YORK Sunline Magnum™ units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS All units include: AND SINGLE PACKAGE • Powder Paint finish that meets ASTM-B-117 1000 hour salt spray standards • Permanently lubricated motors • Bottom or side air discharge configuration capability (field convertible) • Manufactured under the quality standards of ISO9001 • SimplicityTM Control Board • Copper tube/aluminum fin coils • Easy access to all components • Rigging holes in base rails for lifting • Fork lift slots on three sides • Single point power connection • Complete factory package - tested, charged and wired • Belt Drive Indoor Blower • CSA agency listing on all units AIR CONDITIONERS DJ 036, 048 & 060 3, 4 & 5 NOMINAL TONS 13.40 to 13.50 SEER WARRANTY • Factory Limited Parts Warranty • One-year parts warranty • A Five-year parts warranty on the compressor and electric heat elements. • Ten-year parts warranty on the gas-fired heat exchangers. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21687-002-A-1105 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . 12 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . 13 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 43 LIST OF FIGURES 11 DJ048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) . . . . . . . . . . . 18 12 DJ060 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) . . . . . . . . . . . . . . 19 13 DJ060 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) . . . . . . . . 19 14 DJ060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) . . . . . . . . . . . . . . . . 20 Pg. # 15 DJ060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) . . . . . . . . . . . 20 1 UNIT CUTAWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 16 DJ036 COOLING CAPACITIES (3 TON) . . . . . . . . 21 2 TYPICAL FIELD POWER & CONTROL WIRING . . 36 17 DJ048 COOLING CAPACITIES (4 TON) . . . . . . . . 22 3 UNIT DIMENSIONS (3 - 5 TON COOLING ONLY/ ELECTRIC HEAT) FRONT VIEW . . . . . . . . . . . . . . 37 18 DJ060 COOLING CAPACITIES (5 TON) . . . . . . . . 23 Fig. # 4 UNIT DIMENSIONS (3 - 5 TON COOLING/GAS HEAT) FRONT VIEW . . . . . . . . . . . . . . . . . . . . . . . 37 5 UNIT WITH ECONOMIZER RAINHOOD . . . . . . . . 38 6 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD . . . . . . . . . . . . . . . . . . . . . . . 38 7 UNIT DIMENSIONS (REAR VIEW) . . . . . . . . . . . . . 39 8 DISCONNECT/BLOWER ACCESS LOCATION . . . 39 9 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . . . 40 10 FOUR AND SIX POINT LOADING . . . . . . . . . . . . . 41 11 ROOF CURB DIMENSIONS . . . . . . . . . . . . . . . . . . 42 LIST OF TABLES Tbl. # Pg. # 1 CAPACITY RATINGS - (ARI 210/240) . . . . . . . . . . 14 2 GAS HEAT RATINGS . . . . . . . . . . . . . . . . . . . . . . . 14 3 2 STAGE GAS HEAT RATINGS . . . . . . . . . . . . . . . 14 4 DJ036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) . . . . . . . . . . . . . . 15 19 SUPPLY AIR BLOWER PERFORMANCE (DJ036 BELT DRIVE) - SIDE DUCT APPLICATION . . . . . 24 20 SUPPLY AIR BLOWER PERFORMANCE (DJ036 BELT DRIVE) - BOTTOM DUCT APPLICATION . . 25 21 SUPPLY AIR BLOWER PERFORMANCE (DJ048 BELT DRIVE) - SIDE DUCT APPLICATION . . . . . 26 22 SUPPLY AIR BLOWER PERFORMANCE (DJ048 BELT DRIVE) - BOTTOM DUCT APPLICATION . . 27 23 SUPPLY AIR BLOWER PERFORMANCE (DJ060 BELT DRIVE) - SIDE DUCT APPLICATION . . . . . 28 24 SUPPLY AIR BLOWER PERFORMANCE (DJ060 BELT DRIVE) - BOTTOM DUCT APPLICATION . . 29 25 BELT DRIVE BLOWER MOTOR AND DRIVE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 26 STATIC RESISTANCES . . . . . . . . . . . . . . . . . . . . 30 27 ELECTRIC HEATER CFM LIMITATIONS . . . . . . . 30 28 ELECTRICAL DATA - DJ036, 048 & 060 BELT DRIVE W/O POWERED CONVENIENCE OUTLET . . . . . 31 29 ELECTRICAL DATA - DJ036, 048 & 060 BELT DRIVE WITH POWERED CONVENIENCE OUTLET . . . . 33 30 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5 DJ036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) . . . . . . . . 15 31 ELECTRIC HEAT CORRECTION FACTORS . . . . 35 6 DJ036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) . . . . . . . . . . . . . . . . . 16 33 UTILITIES ENTRY . . . . . . . . . . . . . . . . . . . . . . . . . 39 7 DJ036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) . . . . . . . . . . . 16 8 DJ048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) . . . . . . . . . . . . . . 17 9 DJ048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) . . . . . . . . 17 32 VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . . 35 34 MINIMUM CLEARANCES . . . . . . . . . . . . . . . . . . . 39 35 DJ 4 AND 6 POINT LOADS WEIGHT DISTRIBUTION . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 36 CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . . . 41 37 OPERATING WEIGHTS (LBS.) . . . . . . . . . . . . . . . 42 10 DJ048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) . . . . . . . . . . . . . . . . . 18 2 Unitary Products Group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nitary Products Group 3 036-21687-002-A-1105 PRODUCT NOMENCLATURE - Continued 3-5T Sunline Model Number Nomenclature Standard Cabinet AA AB AC AD AE AF AG AH AJ AK AL AM AN AS CA CB CC CD CE CF CG CH CJ CK CL CM CN CP CQ CR CS CT CU CV CW CX JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ 4 None Phase Monitor Coil Guard Dirty Filter Switch Phase Monitor & Coil Guard Phase Monitor & Dirty Filter Switch Coil Guard & Dirty Filter Switch Phase Monitor, Coil Guard, & Dirty Filter Switch SS Drain Pan SS Drain Pan & Phase Monitor SS Drain Pan & Coil Guard SS Drain Pan & Dirty Filter Switch SS Drain Pan, Phase Monitor, Coil Guard & Dirty Filter Switch Bottom Drain Connection CPC Controller with Dirty Filter Switch & Air Proving Switch CPC Controller, DFS, APS & Phase Monitor CPC Controller, DFS, APS & Coil Guard CPC Controller, DFS, APS, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Cond. Coil CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. Coil CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard CPC Controller, DFS, APS, SS Drain Pan CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch Johnson UNT Controller, DFS, APS & Phase Monitor Johnson UNT Controller, DFS, APS & Coil Guard Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Unitary Products Group 036-21687-002-A-1105 Standard Cabinet JR JS JT JU JV JW JX HA HB HC HD HE HF HG HH HJ HK HL HM HN HP HQ HR HS HT HU HV HW HX NA NB NC ND NE NF NG NH NJ NK NL NM NN NP NQ NR NS NT NU NV NW NX TA TB TC Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS, SS Drain Pan Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch Honeywell Excel 10 Controller, DFS, APS & Phase Monitor Honeywell Excel 10 Controller, DFS, APS & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch Novar ETC-3 Controller, DFS, APS & Phase Monitor Novar ETC-3 Controller, DFS, APS & Coil Guard Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS, SS Drain Pan Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Novar ETC-3, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Technicoat Condenser Coil Technicoat Condenser Coil & Phase Monitor Technicoat Condenser Coil & Coil Guard Unitary Products Group 5 036-21687-002-A-1105 Standard Cabinet TD TE TF TG TH TJ TK TL TM TN TP TQ TR TS TT TU TV TW TX TY TZ T1 T3 T4 T6 T7 T9 LA LB LC LD LE LF LG LH LJ LK LL LM LN LP LQ LR LS LT LU LV LW LX WA WB WC WD WE 6 Technicoat Condenser Coil & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, & Coil Guard Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil Technicoat Evaporator Coil & Phase Monitor Technicoat Evaporator Coil & Coil Guard Technicoat Evaporator Coil & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, & Coil Guard Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils Technicoat Evaporator & Condenser Coils & Phase Monitor Technicoat Evaporator & Condenser Coils & Coil Guard Technicoat Evaporator & Condenser Coils & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Condenser & SS Drain Pan Technicoat Condenser Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & SS Drain Pan Technicoat Evaporator Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils & SS Drain Pan Technicoat Evaporator & Condenser Coils, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Simplicity Intelli-Comfort Controller Simplicity Intelli-Comfort Controller, & Phase Monitor Simplicity Intelli-Comfort Controller, & Coil Guard Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Evap. & Cond Coils Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, SS Drain Pan Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Cond Coils Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap Coil Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Intelli-Comfort w/Mod Link Controller Intelli-Comfort w/Mod Link Controller, & Phase Monitor Intelli-Comfort w/Mod Link Controller, & Coil Guard Intelli-Comfort w/Mod Link Controller, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Cond. Coil Unitary Products Group 036-21687-002-A-1105 Standard Cabinet WF WG WH WJ WK WL WM WN WP WQ WR WS WT WU WV WW WX Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. & Cond Coils Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, SS Drain Pan Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Cond Coils Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap Coil Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Cabinet BA BB BC BD BE BF BG BH BJ BK BL BM BN BS DA DB DC DD DE DF DG DH DJ DK DL DM DN DP DQ DR DS DT DU DV DW Hinged Filter Door & Toolless Access Panels Phase Monitor, Hinged Filter Door & Toolless Access Panels Coil Guard, Hinged Filter Door & Toolless Access Panels Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Phase Monitor & Coil Guard, Hinged Filter Door & Toolless Access Panels Phase Monitor & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Coil Guard & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Hinged Filter Door & Toolless Access Panels SS Drain Pan & Phase Monitor, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Coil Guard, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Phase Monitor & Coil Guard, Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Bottom Drain Connection, Hinged Filter Door & Toolless Access Panels CPC Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Unitary Products Group 7 036-21687-002-A-1105 Hinged Filter Door & Toolless Access Cabinet DX EA EB EC ED EE EF EG EH EJ EK EL EM EN EP EQ ER ES ET EU EV EW EX GA GB GC GD GE GF GG GH GJ GK GL GM GN GP GQ GR GS GT GU GV GW GX PA PB 8 CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Unitary Products Group 036-21687-002-A-1105 Hinged Filter Door & Toolless Access Cabinet PC PD PE PF PG PH PJ PK PL PM PN PP PQ PR Novar ETC-3 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels PS Novar ETC-3 Controller, DFS, APS, SS Drain Pan PT Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard PU Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils PV Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil PW Novar ETC-3, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils PX Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils UA Technicoat Condenser Coil, Hinged Filter Door & Toolless Access Panels UB Technicoat Condenser Coil & Phase Monitor, Hinged Filter Door & Toolless Access Panels UC Technicoat Condenser Coil & Coil Guard, Hinged Filter Door & Toolless Access Panels UD Technicoat Condenser Coil & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UE Technicoat Condenser Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UJ Technicoat Evaporator Coil, Hinged Filter Door & Toolless Access Panels UK Technicoat Evaporator Coil & Phase Monitor, Hinged Filter Door & Toolless Access Panels UL Technicoat Evaporator Coil & Coil Guard, Hinged Filter Door & Toolless Access Panels UM Technicoat Evaporator Coil & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UN Technicoat Evaporator Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UP Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UQ Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UR Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels US Technicoat Evaporator & Condenser Coils, Hinged Filter Door & Toolless Access Panels UT Technicoat Evaporator & Condenser Coils & Phase Monitor, Hinged Filter Door & Toolless Access Panels UU Technicoat Evaporator & Condenser Coils & Coil Guard, Hinged Filter Door & Toolless Access Panels UV Technicoat Evaporator & Condenser Coils & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UW Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UX Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UY Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UZ Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U1 Technicoat Condenser & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U3 Technicoat Condenser Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U4 Technicoat Evaporator & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U6 Technicoat Evaporator Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U7 Technicoat Evaporator & Condenser Coils & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U9 Technicoat Evaporator & Condenser Coils, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels QA Simplicity Intelli-Comfort Controller with Hinged Filter Door & Toolless Access Panels QB Simplicity Intelli-Comfort Controller, & Phase Monitor, Hinged Filter Door & Toolless Access Panels QC Simplicity Intelli-Comfort Controller, & Coil Guard, Hinged Filter Door & Toolless Access Panels Unitary Products Group 9 036-21687-002-A-1105 Hinged Filter Door & Toolless Access Cabinet QD QE QF QG QH QJ QK QL QM QN QP QQ QR QS QT QU QV QW QX Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Simplicity Intelli-Comfort Controller, & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Pan Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Simplicity Intelli-Comfort Controller, SS Drain Pan Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels XA Intelli-Comfort w/Mod Link Controller, Hinged Filter Door & Toolless Access Panels XB Intelli-Comfort w/Mod Link Controller, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XC Intelli-Comfort w/Mod Link Controller, & Coil Guard, Hinged Filter Door & Toolless Access Panels XD Intelli-Comfort w/Mod Link Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels XE Intelli-Comfort w/Mod Link Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels XF Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XG Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels XH Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access XJ Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels XK Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XL Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels XM Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access XN Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels XP Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Pan XQ Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels XR Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless XS Intelli-Comfort w/Mod Link Controller, SS Drain Pan Hinged Filter Door & Toolless Access Panels XT Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels XU Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels XV Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels XW Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels XX Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels 10 Unitary Products Group 036-21687-002-A-1105 FEATURES gas valve, if applicable, and the temperature limit switch on gas heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. All models are available with a wide variety of factorymounted options such as stainless steel heat exchangers, electric heaters, phase monitor, convenience outlet, dirty filter switch, disconnect switch, smoke detectors, and coil guard to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with forklift holes on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. • Nuisance Trip Protection- To prevent nuisance trouble calls, the control board uses a “three strikes, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the compressor. • On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. All models are available with these “factory mounted” outdoor air damper options: All units have long lasting powder paint cabinets with 1000 hour salt spray test approval under ASTM-B117 procedures. • Single enthalpy economizer All models are CSA listed. • Motorized outdoor air damper • Warranty - All models include a one-year limited parts warranty on the complete unit. Compressors and electric heater elements carry a five-year warranty. Gas heat exchangers carry a 10-year parts warranty. • Gas Heat Operation - All single phase models with gas heat have minimum annual fuel utilization efficiency (AFUE) of 80%. All three phase models with gas heat have minimum steady state efficiency of 80%. Each section includes a durable heat exchanger with aluminized steel or optional stainless steel tubes, a redundant gas valve, spark ignition, power venting, an ignition module for 100% shut-off and all of the safety controls required to meet the latest ANSI standards. Supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. All compressors are equipped with internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch to protect all system components. • Simplicity™ Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls. • Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0ºF outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. • Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti short cycle delay can be temporarily overridden with the push of a button. • Fan Delays - Fan on and fan off delays are fully programmable and are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the Unitary Products Group The gas supply piping can be routed into the heating compartment through a hole in the base pan of the unit or through a knockout in the piping panel on the front of the unit. • Electric Heat Operation - All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive temperature by thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection (field supplied) in the base pan of the unit or through a knockout in the wiring panel on the side of the unit. • BAS Controls - York’s Sunline™ series units offer factory mounted BAS controls such as SImplicity™ INTELLIComfort™, Novar, Honeywell, Johnson, and CPC. 11 036-21687-002-A-1105 FIGURE 1 - UNIT CUTAWAY FACTORY-INSTALLED OPTIONS • SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • 12 PHENOLIC COATED EVAPORATOR AND CONDENSER COILS - Special coating process that utilizes Technicoat 10-1TM processes. Coating is applied by total immersion of the complete coil for maximum protection. • ELECTRIC HEATERS - Wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. • FILTER OPTIONS - Standard units are shipped with 1” throw-away filters installed. 2” pleated filters are offered as a factory installed option. • CONVENIENCE OUTLET - This 110 volt outlet can be “powered” by the unit with a stepdown transformer or the unit may be ordered with a “non-powered” convenience outlet that can be wired in the field. • DISCONNECT SWITCH - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. • BAS - Building Automation System Controls Simplicity™ INTELLI-Comfort™ CONTROL - The York® Simplicity™ INTELLI-Comfort™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort™ Unitary Products Group 036-21687-002-A-1105 using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the on-board connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity™ INTELLI-Comfort™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. • • Simplicity™ INTELLI-Comfort™ with MOD LINK CONTROL - The York® Simplicity™ INTELLI-Comfort™ with Mod Link control is factory installed. It includes all the features of the INTELLI-Comfort™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. Novar® BAS CONTROL - The Novar® ETC-3 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • JOHNSON CONTROLS BAS CONTROL - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • CPC BAS CONTROL - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. • HONEYWELL BAS CONTROL - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. • SMOKE DETECTORS - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • STAINLESS STEEL HEAT EXCHANGER - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly. Unitary Products Group • STAINLESS STEEL DRAIN PAN - An optional rustproof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. • BOTTOM DRAIN CONNECTION - An optional bottom drain connection is available for inside the curb connections for applications in cold environments to reduce freezing drain lines. • PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-ofphase condition. • DIRTY FILTER SWITCH - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. • HINGED FILTER DOOR/“TOOLLESS” BLOWER AND ACCESS PANELS (not hinged) - This option allows for easy access and maintenance. NOTE:Knobs are shipped inside the unit to prevent shipping damage. These must be field installed for tool-less operation. FIELD-INSTALLED ACCESSORIES • SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • ELECTRIC HEATERS wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. 13 036-21687-002-A-1105 • ROOF CURBS - Eight and fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. • • • Roof curbs are designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. • HIGH ALTITUDE NATURAL GAS - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. ENTHALPY ACCESSORY CONTROL KIT - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. • BURGLAR BARS - Mount in the supply and return openings to prevent entry into the duct work. • FLUE EXHAUST EXTENSION KIT - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes. • CO2 SENSOR - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • HAIL GUARD - Hail Guard kit is available to prevent unit from hail damage. This is a sloped hood that fits above the coil. • GAS PIPING KIT - This kit supplies all necessary fittings and shut off valve. PROPANE - Burner orifices, pilot orifices and gas valve parts are provided to convert a natural gas furnace to propane. • HIGH ALTITUDE PROPANE - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. This accessory supplements the basic propane conversion kit. • LOW NOX KIT - Required to reduce the emission of nitrogen oxides below 40 nano grams per joule. • POWER EXHAUST - Our single input economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. The power exhaust option can only be used on bottom duct configurations. TABLE 1: CAPACITY RATINGS - (ARI 210/240)1 TABLE 2: GAS HEAT RATINGS1 MODEL MBH EER2 SEER3 CFM SOUND RATING (Db)4 DJ036 35.8 11.65 13.50 1200 84 DJ048 46.5 11.75 13.45 1600 83 DJ060 56.5 11.15 13.40 1800 81 1. 80/67°F Indoor and 95°F outdoor. 2. EER = Energy Efficiency Ratio at full load - the cooling capacity in Btu’s per hour (Btuh) divided by the power input in watts, expressed in Btuh per watt (Btuh/watt). 3. SEER = Seasonal Energy Efficiency Ratio. 4. Rated in accordance with ARI 270 Standard. MODEL MBH INPUT MBH OUTPUT AFUE (%) TEMP RISE ºF DJ036N04 DJ036N08 50 100 40 80 80.9 80.5 15 - 45 40 - 70 DJ048N06 DJ048N10 75 125 60 100 80.9 80.3 25 - 55 45 - 75 DJ060N08 DJ060N10 100 125 80 100 80.5 80.3 25 - 55 35 - 65 1. All units are single-stage heating. TABLE 3: 2 STAGE GAS HEAT RATINGS MODEL1 MBH INPUT MBH OUTPUT 1ST STAGE 2ND STAGE 1ST STAGE 2ND STAGE STEADY STATE EFFICIENCY RISE 1ST STAGE 2ND STAGE MIN. MAX. MINIMUM HEATING AIRFLOW (CFM) 790 DJ036D06 45 75 35.8 60.8 79.4 81.1 35 70 DJ036D10 69 115 55.2 92 80.0 80.2 55 90 950 DJ048D06 45 75 35.7 60.8 79.4 81.1 25 70 790 DJ048D10 75 125 60.4 100.6 80.5 80.5 45 75 1230 DJ060D06 45 75 35.8 60.8 79.4 81.1 35 70 1010 DJ060D10 75 125 60.4 100.6 80.5 80.5 45 75 1230 1. Models are 3Ø only. 14 Unitary Products Group 036-21687-002-A-1105 TABLE 4: DJ036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 630 0.2 1116 0.41 Cooling ID Blower Operation2 Only (dB) (dB) 80 82 76 77 56 59 50 50 40 43 41 42 41 41 45 45 DJ036 / 3 Ton / Belt Drive Horizontal Ducted Inlet 631 879 885 0.3 0.2 0.7 928 1979 1020 0.37 0.76 0.53 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 80 82 78 83 81 85 76 77 82 83 81 82 56 60 60 61 58 60 49 50 54 54 51 52 39 42 49 50 44 45 40 42 49 49 43 44 41 41 49 49 41 41 45 45 47 47 45 45 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. TABLE 5: DJ036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 630 0.2 1116 0.41 Cooling ID Blower Operation2 Only (dB) (dB) 80 84 74 77 58 61 48 51 41 45 39 41 41 41 45 45 DJ036 / 3 Ton / Belt Drive Horizontal Ducted Discharge 631 879 885 0.3 0.2 0.7 928 1979 1020 0.37 0.76 0.53 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 80 83 85 87 84 87 74 76 80 82 80 83 58 61 68 68 63 65 47 50 58 58 53 54 39 43 55 55 49 50 37 39 53 53 46 47 38 38 55 55 49 49 44 44 52 53 47 47 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. Unitary Products Group 15 036-21687-002-A-1105 TABLE 6: DJ036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 632 0.2 1069 0.36 Cooling ID Blower Operation2 Only (dB) (dB) 78 82 70 75 55 60 47 50 40 43 37 40 36 37 44 44 DJ036 / 3 Ton / Belt Drive Vertical Ducted Inlet 632 881 883 0.3 0.2 0.7 870 1903 917 0.33 0.71 0.49 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 78 82 80 85 80 84 70 74 71 80 71 79 55 60 59 61 58 62 47 50 52 53 49 52 39 43 50 51 45 46 37 39 45 46 41 43 36 37 45 46 40 40 44 44 45 47 44 44 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. TABLE 7: DJ036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 632 0.2 1069 0.36 Cooling ID Blower Operation2 Only (dB) (dB) 80 83 78 79 55 60 48 51 41 44 37 40 38 39 44 45 DJ036 / 3 Ton / Belt Drive Vertical Ducted Discharge 632 881 883 0.3 0.2 0.7 870 1903 917 0.33 0.71 0.49 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 80 83 83 86 82 85 77 78 80 83 79 82 54 59 63 63 58 62 46 50 58 59 52 53 39 43 54 55 48 49 35 38 50 50 42 44 36 37 52 53 44 44 44 44 49 50 45 45 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. 16 Unitary Products Group 036-21687-002-A-1105 TABLE 8: DJ048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 766 0.2 1484 0.67 Cooling ID Blower Operation2 Only (dB) (dB) 74 97 70 86 53 58 49 55 42 42 40 44 38 44 42 43 DJ048 / 4 Ton / Belt Drive Horizontal Ducted Inlet 769 1077 1087 0.5 0.4 1.0 993 2270 1406 0.54 1.24 0.90 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 74 95 77 90 77 90 69 86 73 78 72 77 52 57 60 61 58 61 47 54 54 56 51 53 38 39 50 55 45 45 38 43 48 51 45 46 36 41 48 52 43 45 42 44 45 48 44 45 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. TABLE 9: DJ048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 766 0.2 1484 0.67 Cooling ID Blower Operation2 Only (dB) (dB) 77 97 72 86 60 62 53 56 47 47 45 46 46 47 47 47 DJ048 / 4 Ton / Belt Drive Horizontal Ducted Discharge 769 1077 1087 0.5 0.4 1.0 993 2270 1406 0.54 1.24 0.90 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 75 95 84 91 82 91 69 85 81 83 78 80 57 59 71 71 66 67 49 54 60 61 55 56 42 43 58 59 52 52 40 43 54 55 50 50 40 42 57 58 52 52 45 45 54 54 48 49 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. Unitary Products Group 17 036-21687-002-A-1105 TABLE 10: DJ048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 791 0.2 1408 0.54 Cooling ID Blower Operation2 Only (dB) (dB) 76 95 68 84 54 57 48 53 43 44 40 43 38 43 43 43 DJ048 / 4 Ton / Belt Drive Vertical Ducted Inlet 794 1084 1095 0.5 0.2 1.0 1000 2336 1275 0.42 1.12 0.73 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 77 93 80 91 79 91 67 82 76 84 73 80 52 56 63 61 57 59 46 53 54 57 50 53 40 41 52 52 47 47 38 42 49 51 44 46 36 40 49 54 43 45 43 43 45 47 44 44 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. TABLE 11: DJ048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 791 0.2 1408 0.54 Cooling ID Blower Operation2 Only (dB) (dB) 78 95 73 84 56 58 51 54 46 46 42 44 43 45 44 44 DJ048 / 4 Ton / Belt Drive Vertical Ducted Discharge 794 1084 1095 0.5 0.2 1.0 1000 2336 1275 0.42 1.12 0.73 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 77 93 85 92 82 91 72 82 84 87 78 82 53 56 68 68 60 61 48 53 61 62 54 55 43 44 57 57 50 50 38 42 53 54 46 48 39 41 55 57 49 50 43 43 52 52 46 47 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. 18 Unitary Products Group 036-21687-002-A-1105 TABLE 12: DJ060 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) 81,7'(6&5,37,2102'(/ &21),*85$7,21 ,QGRRU%ORZHU6SHHG530 %ORZHU6WDWLF3UHVVXUH,:* $LUIORZ&)0 %ORZHU0RWRU%+3 2FWDYH&HQWHU)UHT &RROLQJ ,'%ORZHU 2SHUDWLRQ 2QO\G% G% '-7RQ%HOW'ULYH +RUL]RQWDO'XFWHG,QOHW &RROLQJ &RROLQJ &RROLQJ ,'%ORZHU ,'%ORZHU ,'%ORZHU 2SHUDWLRQ 2SHUDWLRQ 2SHUDWLRQ 2QO\G% 2QO\G% 2QO\G% G% G% G% 5 60 5 53 50 4 4 7HVWHGLQDFFRUGDQFHZLWK$5,6WDQGDUG5HIHUWR6WDQGDUGIRU6RXQG5DWLQJRI'XFWHG$LU0RYLQJDQG&RQGLWLRQLQJ(TXLSPHQW &RROLQJ2SHUDWLRQ±,'EORZHUFRPSUHVVRUDQGRXWGRRUIDQRSHUDWLQJ 7HVW'XFW'LPHQVLRQLQZLGH[LQKLJK[IWORQJP[P[P 7HVWGXFWWHUPLQDWLRQLVIOXVKZLWKUHYHUEHUDWLRQURRPZDOO 'XFWHQGVRXQGUHIOHFWLRQFRUUHFWLRQG%DWNNN+] TABLE 13: DJ060 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) 81,7'(6&5,37,2102'(/ &21),*85$7,21 ,QGRRU%ORZHU6SHHG530 %ORZHU6WDWLF3UHVVXUH,:* $LUIORZ&)0 %ORZHU0RWRU%+3 2FWDYH&HQWHU)UHT &RROLQJ ,'%ORZHU 2SHUDWLRQ 2QO\G% G% '-7RQ%HOW'ULYH +RUL]RQWDO'XFWHG'LVFKDUJH &RROLQJ &RROLQJ &RROLQJ ,'%ORZHU ,'%ORZHU ,'%ORZHU 2SHUDWLRQ 2SHUDWLRQ 2SHUDWLRQ 2QO\G% 2QO\G% 2QO\G% G% G% G% 7HVWHGLQDFFRUGDQFHZLWK$5,6WDQGDUG5HIHUWR6WDQGDUGIRU6RXQG5DWLQJRI'XFWHG$LU0RYLQJDQG&RQGLWLRQLQJ(TXLSPHQW &RROLQJ2SHUDWLRQ±,'EORZHUFRPSUHVVRUDQGRXWGRRUIDQRSHUDWLQJ 7HVW'XFW'LPHQVLRQLQZLGH[LQKLJK[IWORQJP[P[P 7HVWGXFWWHUPLQDWLRQLVIOXVKZLWKUHYHUEHUDWLRQURRPZDOO 'XFWHQGVRXQGUHIOHFWLRQFRUUHFWLRQG%DWNNN+] Unitary Products Group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±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±,'EORZHUFRPSUHVVRUDQGRXWGRRUIDQRSHUDWLQJ 7HVW'XFW'LPHQVLRQLQZLGH[LQKLJK[IWORQJP[P[P 7HVWGXFWWHUPLQDWLRQLVIOXVKZLWKUHYHUEHUDWLRQURRPZDOO 'XFWHQGVRXQGUHIOHFWLRQFRUUHFWLRQG%DWNNN+] 20 Unitary Products Group 036-21687-002-A-1105 TABLE 16: DJ036 COOLING CAPACITIES (3 TON) Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 900 1050 1200 1350 1500 900 1050 1200 1350 1500 900 1050 1200 1350 1500 WB (°F) 75°F Total Total2 Cap.1 Input (MBH) (kW) 85°F Sensible Capacity (MBH)1 Return Dry Bulb (°F) Total Total2 Cap.1 Input (MBH) (kW) Sensible Capacity (MBH)1 Return Dry Bulb (°F) 86 83 80 77 74 71 68 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 44 42 40 39 44 42 40 39 44 43 40 39 45 43 41 40 46 44 42 41 2.3 2.3 2.3 2.3 2.2 2.3 2.3 2.3 2.2 2.3 2.3 2.3 2.2 2.3 2.3 2.3 2.3 2.3 2.3 2.3 24 30 40 39 26 33 40 39 28 35 40 39 30 37 41 40 32 40 42 41 21 28 35 37 23 30 38 38 25 32 40 39 26 33 41 40 27 35 42 41 16 23 30 32 17 24 32 34 18 25 33 36 18 25 35 36 18 26 37 36 14 20 28 30 14 21 29 31 14 21 30 32 14 21 31 32 14 22 33 32 18 25 27 18 26 28 18 26 29 18 27 28 17 28 27 15 23 25 15 23 25 14 23 25 14 23 24 13 24 23 41 38 35 35 42 39 35 35 43 40 36 36 43 40 37 36 44 41 37 37 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 23 29 35 35 25 31 35 35 27 34 36 36 29 36 37 36 31 39 37 37 20 26 32 34 22 28 34 35 24 31 36 36 25 32 37 36 27 34 37 37 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 38 35 30 30 39 36 31 31 41 37 32 32 41 37 32 33 42 38 33 33 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 21 27 30 30 24 30 31 31 26 33 32 32 28 35 32 33 30 38 33 33 19 24 29 30 21 27 31 31 23 30 32 32 24 31 32 33 26 33 33 33 14 19 24 25 15 21 26 27 16 23 29 29 16 23 28 29 17 24 28 29 11 17 22 22 12 18 23 24 12 19 25 25 12 19 24 25 12 20 24 24 14 19 19 15 20 21 16 22 22 15 20 21 15 19 20 12 17 17 12 17 18 12 18 18 11 16 17 11 15 15 35 31 27 27 36 32 28 28 37 33 29 29 37 33 29 29 37 33 29 29 3.0 2.9 3.0 3.0 3.0 2.9 2.9 2.9 2.9 2.8 2.9 2.9 3.0 2.9 2.9 2.9 3.1 2.9 3.0 3.0 20 25 27 27 22 28 28 28 25 31 29 29 27 32 29 29 28 33 29 29 17 23 26 27 19 25 28 28 21 28 29 29 23 29 29 29 24 31 29 29 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 32 27 24 25 32 28 25 25 33 29 25 26 33 29 25 26 33 28 25 25 3.3 3.1 3.2 3.2 3.3 3.0 3.1 3.1 3.2 3.0 3.1 3.1 3.3 3.1 3.2 3.2 3.4 3.2 3.3 3.3 18 23 24 25 21 26 25 25 23 29 25 26 25 29 25 26 27 28 25 25 16 21 23 25 18 23 24 25 20 26 25 26 21 27 25 26 22 28 25 25 19 25 33 35 20 27 35 37 21 28 37 39 22 29 39 40 23 31 42 41 95°F 16 22 27 27 18 24 30 30 19 26 32 32 20 27 32 33 21 29 33 33 115°F 13 18 21 23 15 20 23 25 16 22 25 27 17 23 25 26 18 25 25 25 11 16 18 20 12 17 20 22 13 19 22 24 13 19 21 22 13 20 20 21 8 13 16 17 9 14 17 19 9 15 18 20 9 15 17 18 9 16 16 16 11 13 15 11 14 16 12 15 17 11 13 14 11 11 12 8 11 12 8 11 13 8 11 13 8 9 10 7 7 8 28 24 21 22 29 24 21 22 29 25 22 22 29 24 21 22 28 24 21 22 3.7 3.3 3.5 3.5 3.5 3.2 3.4 3.4 3.4 3.1 3.3 3.3 3.6 3.2 3.4 3.4 3.8 3.4 3.6 3.6 17 22 21 22 19 24 21 22 21 25 22 22 23 24 21 22 25 24 21 22 14 19 20 22 16 22 21 22 18 24 22 22 19 24 21 22 20 24 21 22 80 18 24 30 31 19 25 32 33 20 27 34 36 21 28 36 36 22 30 37 37 105°F 15 20 24 25 16 22 26 27 18 24 29 30 19 25 29 30 20 27 29 29 125°F 12 17 18 20 13 18 20 22 14 20 22 22 15 21 21 22 16 23 21 22 77 74 71 68 15 21 27 28 16 22 29 30 17 24 31 32 17 24 32 32 18 25 33 32 12 18 25 26 13 19 26 27 13 20 27 29 13 20 28 28 13 21 28 28 16 22 23 16 23 24 17 24 25 16 24 24 16 24 23 13 20 21 13 20 21 13 20 22 12 20 20 12 19 19 12 18 21 22 13 19 23 24 14 21 25 26 15 21 25 26 15 22 24 25 10 15 19 20 10 16 20 21 11 17 22 23 11 17 21 22 11 18 20 20 12 16 17 13 17 18 14 18 19 13 17 18 13 15 16 10 14 15 10 14 15 10 15 16 9 13 14 9 11 11 9 14 15 18 10 15 17 19 11 17 18 21 11 17 17 19 11 18 16 17 7 11 13 15 7 12 14 16 7 13 15 18 7 13 13 15 7 14 12 13 9 10 13 9 11 13 10 11 14 10 9 11 9 7 8 6 8 10 6 8 10 6 8 11 6 5 7 5 3 4 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 21 036-21687-002-A-1105 TABLE 17: DJ048 COOLING CAPACITIES (4 TON) Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 1200 1400 1600 1800 2000 1200 1400 1600 1800 2000 1200 1400 1600 1800 2000 WB (°F) 75°F Total Total2 Cap.1 Input (MBH) (kW) 85°F Sensible Capacity (MBH)1 Return Dry Bulb (°F) Total Total2 Cap.1 Input (MBH) (kW) Sensible Capacity (MBH)1 Return Dry Bulb (°F) 86 83 80 77 74 71 68 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 58 57 53 51 58 56 53 51 57 56 53 51 57 56 53 51 57 55 52 50 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 32 43 53 51 34 45 53 51 36 48 53 51 39 52 53 51 41 55 52 50 28 39 47 51 30 41 50 51 32 43 53 51 33 46 53 51 35 48 52 50 22 32 40 45 22 33 41 47 22 34 43 48 23 35 45 46 23 36 46 44 18 29 37 42 18 29 37 43 18 29 38 43 17 30 39 41 17 30 40 38 26 33 38 25 33 39 25 33 39 24 34 36 24 34 32 22 30 35 21 29 34 20 29 34 19 29 30 18 28 26 54 51 47 46 55 52 48 46 55 52 48 47 55 52 48 47 55 52 48 46 3.1 3.1 3.0 3.0 3.1 3.1 3.0 3.0 3.1 3.1 3.1 3.0 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 30 40 47 46 33 43 48 46 36 46 48 47 38 49 48 47 41 52 48 46 27 36 44 46 29 39 46 46 31 42 48 47 33 44 48 47 35 47 48 46 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 50 45 41 40 52 47 42 42 54 49 44 43 53 48 44 43 53 48 43 42 3.3 3.4 3.3 3.3 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.3 29 37 41 40 32 41 42 42 35 45 44 43 38 46 44 43 41 48 43 42 25 33 41 40 28 37 42 42 30 40 44 43 33 43 44 43 35 46 43 42 18 27 34 33 20 29 37 36 21 31 39 39 22 32 38 38 23 34 37 37 15 23 31 30 16 25 33 32 16 26 35 34 17 27 33 32 17 28 31 31 20 27 26 20 29 28 21 30 29 22 28 27 22 25 25 16 24 23 16 24 24 17 25 25 16 22 22 16 19 19 45 39 36 35 47 41 37 37 49 43 39 39 49 43 39 38 48 42 38 38 3.7 3.7 3.6 3.6 3.7 3.7 3.6 3.6 3.7 3.7 3.6 3.6 3.7 3.7 3.6 3.7 3.7 3.7 3.7 3.7 27 34 36 35 30 38 37 37 33 41 39 39 36 42 39 38 39 42 38 38 23 31 36 35 26 34 37 37 28 37 39 39 31 39 39 38 33 41 38 38 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 40 34 31 30 42 36 32 32 45 38 34 34 44 37 34 33 43 36 33 33 4.0 3.9 3.9 3.9 4.0 4.0 3.9 3.9 4.0 4.0 3.9 4.0 4.0 4.0 4.0 4.0 4.1 4.0 4.0 4.0 25 32 31 30 28 35 32 32 31 38 34 34 34 37 34 33 37 36 33 33 21 28 31 30 24 32 32 32 27 35 34 34 29 36 34 33 31 36 33 33 25 36 44 49 26 37 46 51 27 39 47 53 28 40 50 52 29 42 52 50 95°F 22 30 37 37 24 33 41 40 26 35 44 43 27 38 44 43 29 40 43 42 115°F 18 25 28 28 20 28 31 31 22 30 34 34 24 33 34 33 25 35 33 33 14 21 25 24 16 24 27 27 17 26 30 29 18 27 28 28 19 29 27 27 11 18 21 21 12 20 23 23 13 21 25 25 13 22 23 23 13 23 21 21 15 18 17 16 19 19 16 20 20 17 18 17 17 15 15 11 14 14 11 15 15 12 16 15 11 12 12 11 9 9 35 28 26 25 38 30 28 27 40 32 29 29 39 31 29 29 39 31 28 28 4.3 4.2 4.2 4.2 4.3 4.3 4.2 4.3 4.3 4.3 4.2 4.3 4.4 4.3 4.3 4.3 4.4 4.3 4.3 4.3 23 28 26 25 26 30 28 27 29 32 29 29 32 31 29 29 35 31 28 28 19 26 26 25 22 29 28 27 25 32 29 29 27 31 29 29 29 31 28 28 80 23 33 41 43 25 35 43 45 26 37 46 48 28 39 47 47 29 41 48 46 105°F 20 27 33 32 22 30 36 35 24 33 39 39 25 35 39 38 27 37 38 38 125°F 16 22 23 23 18 25 26 26 20 28 29 29 22 30 29 29 23 31 28 28 77 74 71 68 20 29 37 39 21 31 39 41 22 32 41 43 22 34 41 42 23 35 42 40 17 26 34 36 17 27 35 37 17 28 36 39 17 28 36 37 17 29 36 34 23 30 32 23 31 33 23 32 34 23 31 31 23 30 28 19 27 29 19 27 29 18 27 29 18 25 26 17 24 23 16 24 29 29 18 26 32 31 19 28 34 34 20 30 33 33 21 31 32 32 13 21 26 25 14 22 28 27 14 24 30 29 15 24 28 27 15 25 26 26 17 22 22 18 24 23 19 25 25 19 23 22 19 20 20 14 19 19 14 20 19 14 20 20 14 17 17 14 14 14 13 19 20 20 14 21 22 22 15 23 25 24 16 25 23 23 17 27 22 22 9 15 16 16 10 17 18 18 11 19 20 20 11 20 18 18 11 21 16 16 12 13 13 13 14 14 14 15 15 14 13 13 15 10 10 9 10 9 9 10 10 9 11 10 9 8 7 9 4 4 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 22 Unitary Products Group 036-21687-002-A-1105 TABLE 18: DJ060 COOLING CAPACITIES (5 TON) Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 1600 1800 2000 2250 2500 1600 1800 2000 2250 2500 1600 1800 2000 2250 2500 WB (°F) 75°F Total Total2 Cap.1 Input (MBH) (kW) 85°F Sensible Capacity (MBH)1 Return Dry Bulb (°F) Total Total2 Cap.1 Input (MBH) (kW) Sensible Capacity (MBH)1 Return Dry Bulb (°F) 86 83 80 77 74 71 68 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 73 65 58 55 76 67 60 57 79 70 63 60 80 70 63 60 80 70 63 60 3.4 3.4 3.4 3.4 3.4 3.5 3.4 3.4 3.4 3.5 3.4 3.4 3.4 3.5 3.4 3.4 3.4 3.5 3.4 3.4 41 50 58 55 45 54 60 57 48 58 63 60 53 64 63 60 57 70 63 60 37 45 56 56 40 48 59 58 43 52 63 60 46 56 63 60 50 60 63 60 29 37 47 49 30 38 50 51 31 40 52 54 33 43 54 53 35 45 56 52 24 32 43 45 25 33 45 46 25 34 46 48 26 36 47 46 27 38 48 45 28 39 40 28 39 41 28 40 42 29 41 40 30 41 37 24 34 36 23 34 36 23 34 36 23 34 33 23 33 30 67 60 54 52 69 62 56 54 72 64 58 56 72 65 58 56 73 65 59 57 3.9 3.9 3.8 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 39 47 54 52 42 52 56 54 46 56 58 56 50 61 58 56 54 65 59 57 34 43 52 52 37 47 55 54 40 50 58 56 43 54 58 56 46 58 59 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 61 56 51 50 62 57 52 51 64 59 53 52 65 59 54 53 66 60 55 54 4.4 4.4 4.3 4.4 4.4 4.4 4.3 4.4 4.4 4.4 4.3 4.4 4.5 4.4 4.3 4.4 4.5 4.4 4.4 4.4 36 45 51 50 40 50 52 51 44 55 53 52 47 57 54 53 51 60 55 54 31 41 49 48 35 45 51 50 38 49 53 52 41 52 54 53 43 55 55 54 23 32 40 40 25 35 44 43 26 37 47 46 27 39 47 46 28 40 47 46 19 28 36 36 20 30 38 38 21 31 41 41 21 32 40 40 21 33 40 39 24 32 31 25 33 33 26 35 35 26 34 33 26 32 31 19 27 27 20 28 28 20 29 29 19 27 26 18 25 24 57 51 47 47 58 52 48 48 59 53 48 48 60 54 49 49 60 54 49 49 5.0 4.9 4.9 4.9 5.0 4.9 4.9 4.9 5.0 4.9 4.9 4.9 5.0 4.9 4.9 5.0 5.1 5.0 4.9 5.0 33 43 47 47 37 47 48 48 41 51 48 48 44 53 49 49 47 54 49 49 29 38 45 45 32 42 47 47 35 46 48 48 37 49 49 49 39 52 49 49 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 53 47 43 44 53 47 43 44 54 48 44 45 54 48 44 45 55 48 44 45 5.6 5.5 5.4 5.5 5.6 5.5 5.4 5.5 5.5 5.5 5.4 5.5 5.6 5.5 5.4 5.5 5.6 5.5 5.5 5.6 30 40 43 44 34 44 43 44 37 48 44 45 40 48 44 45 43 48 44 45 26 36 41 41 29 40 42 43 32 44 44 45 34 46 44 45 36 48 44 45 33 41 52 53 35 43 55 56 37 46 58 60 39 49 60 60 42 53 63 60 95°F 27 36 44 44 30 40 49 48 32 43 53 52 34 46 54 53 36 48 55 54 115°F 21 32 36 37 24 35 40 41 26 38 44 45 27 40 44 45 28 42 44 45 17 28 32 33 19 30 35 36 20 32 38 39 20 33 37 38 21 34 37 38 13 23 28 29 14 25 30 31 14 26 32 33 14 27 31 32 13 27 29 30 19 24 24 20 25 26 21 26 27 20 24 25 20 22 23 15 19 20 15 20 21 15 20 21 13 17 18 12 14 15 49 42 39 41 49 42 39 41 49 42 39 41 49 42 39 41 49 42 39 41 6.1 6.0 6.0 6.1 6.1 6.0 6.0 6.1 6.1 6.0 5.9 6.1 6.1 6.0 6.0 6.1 6.2 6.1 6.0 6.2 27 38 39 41 31 41 39 41 34 42 39 41 37 42 39 41 39 42 39 41 23 34 37 38 26 38 38 39 28 41 39 41 30 42 39 41 32 42 39 41 80 30 39 48 49 32 42 52 52 34 45 55 56 37 47 57 56 39 50 59 57 105°F 24 34 40 41 27 37 44 44 29 41 48 48 30 43 49 49 32 45 49 49 125°F 19 29 32 34 21 33 36 37 23 36 39 41 24 37 39 41 25 39 39 41 77 74 71 68 26 34 44 44 27 37 47 47 29 39 49 50 30 41 50 50 31 43 51 49 21 30 39 40 22 32 41 42 23 33 44 44 23 34 44 43 24 35 44 42 26 35 36 26 36 37 27 38 38 27 37 36 28 36 34 22 31 31 21 31 32 21 32 33 21 30 30 20 29 27 20 30 36 36 22 32 39 39 23 35 42 43 24 36 42 42 25 37 42 42 16 26 32 32 17 27 34 34 17 29 36 37 17 29 35 36 17 30 34 34 21 28 28 22 29 29 23 31 31 23 29 29 23 27 27 17 23 24 17 24 24 17 25 25 16 22 22 15 20 20 14 25 28 29 16 27 31 32 17 30 33 35 17 31 32 34 17 31 32 33 10 21 24 25 10 22 26 27 11 24 27 29 10 24 26 27 10 24 24 26 17 20 21 17 21 22 18 22 23 17 19 21 16 17 18 12 15 17 12 16 17 12 16 17 11 13 14 9 9 11 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 23 036-21687-002-A-1105 TABLE 19: SUPPLY AIR BLOWER PERFORMANCE (DJ036 BELT DRIVE) - SIDE DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS 800 ---- ---- ---- ---- ---- ---- 696 357 0.38 743 389 0.42 786 422 0.45 900 ---- ---- ---- 656 353 0.38 706 385 0.41 753 417 0.45 797 450 0.48 0.2 0.3 0.4 0.5 0.6 BHP 1000 ---- ---- ---- 671 376 0.40 722 408 0.44 768 440 0.47 812 473 0.51 1100 634 364 0.39 690 398 0.43 741 431 0.46 787 463 0.50 831 496 0.53 1200 656 389 0.42 712 423 0.45 763 455 0.49 809 488 0.52 853 520 0.56 1300 681 418 0.45 737 452 0.49 787 485 0.52 834 517 0.55 877 550 0.59 1400 707 454 0.49 763 488 0.52 813 520 0.56 860 552 0.59 903 585 0.63 1500 735 496 0.53 791 530 0.57 841 562 0.60 887 594 0.64 931 627 0.67 1600 763 545 0.58 819 579 0.62 870 612 0.66 916 644 0.69 960 677 0.73 1700 793 602 0.65 849 636 0.68 900 669 0.72 946 701 0.75 990 734 0.79 1800 824 667 0.72 880 701 0.75 930 733 0.79 977 765 0.82 1021 798 0.86 1900 855 739 0.79 911 773 0.83 962 806 0.86 1008 838 0.90 1052 871 0.93 2000 887 819 0.88 943 853 0.92 994 886 0.95 1040 918 0.98 1084 951 1.02 AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 800 829 457 0.49 872 495 0.53 916 538 0.58 964 586 0.63 1017 642 0.69 0.7 0.8 0.9 1.0 1.1 900 839 485 0.52 882 524 0.56 927 566 0.61 975 615 0.66 1027 670 0.72 1000 854 508 0.55 897 547 0.59 942 589 0.63 990 638 0.68 1043 693 0.74 1100 874 531 0.57 916 569 0.61 961 612 0.66 1009 660 0.71 1062 715 0.77 1200 896 555 0.60 938 594 0.64 983 636 0.68 1031 685 0.73 1084 740 0.79 1300 920 585 0.63 963 623 0.67 1007 666 0.71 1055 714 0.77 1108 770 0.83 1400 946 620 0.67 989 659 0.71 1034 701 0.75 1082 750 0.80 ---- ---- ---- 1500 974 662 0.71 1017 701 0.75 1061 743 0.80 1109 792 0.85 ---- ---- ---- 1600 1003 712 0.76 1045 750 0.80 1090 793 0.85 ---- ---- ---- ---- ---- ---- 1700 1032 769 0.82 1075 807 0.87 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1063 833 0.89 1106 872 0.94 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1094 906 0.97 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK74 blower sheave and A39 belt. AK61 blower sheave and A36 belt - Field installation required. 24 Unitary Products Group 036-21687-002-A-1105 TABLE 20: SUPPLY AIR BLOWER PERFORMANCE (DJ036 BELT DRIVE) - BOTTOM DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS 800 ---- ---- ---- ---- ---- ---- ---- ---- ---- 749 384 0.41 791 422 0.45 900 ---- ---- ---- ---- ---- ---- 720 364 0.39 764 404 0.43 806 443 0.47 0.2 0.3 0.4 0.5 0.6 BHP 1000 ---- ---- ---- 690 346 0.37 739 388 0.42 783 429 0.46 824 467 0.50 1100 657 334 0.36 711 376 0.40 760 417 0.45 804 458 0.49 845 497 0.53 1200 681 369 0.40 735 410 0.44 784 452 0.49 828 493 0.53 869 532 0.57 1300 707 409 0.44 761 451 0.48 809 493 0.53 854 534 0.57 895 572 0.61 1400 735 456 0.49 789 498 0.53 837 540 0.58 882 581 0.62 923 619 0.66 1500 765 509 0.55 819 550 0.59 867 592 0.64 911 633 0.68 953 672 0.72 1600 796 567 0.61 850 609 0.65 899 651 0.70 943 692 0.74 984 730 0.78 1700 829 631 0.68 883 673 0.72 932 715 0.77 976 756 0.81 1017 794 0.85 1800 863 701 0.75 918 743 0.80 966 785 0.84 1010 826 0.89 1051 864 0.93 1900 899 776 0.83 953 818 0.88 1001 860 0.92 1045 901 0.97 1087 939 1.01 2000 936 857 0.92 990 899 0.96 1038 941 1.01 1082 981 1.05 ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 800 831 456 0.49 871 486 0.52 914 509 0.55 961 525 0.56 1012 532 0.57 0.7 0.8 0.9 1.0 1.1 900 846 477 0.51 886 507 0.54 929 530 0.57 976 546 0.59 1027 553 0.59 1000 864 502 0.54 905 531 0.57 947 555 0.60 994 571 0.61 1046 578 0.62 1100 885 531 0.57 926 561 0.60 969 584 0.63 1015 600 0.64 1067 607 0.65 1200 909 566 0.61 950 596 0.64 992 619 0.66 1039 635 0.68 1091 642 0.69 1300 935 607 0.65 976 636 0.68 1018 660 0.71 1065 676 0.72 ---- ---- ---- 1400 963 654 0.70 1004 683 0.73 1046 707 0.76 1093 722 0.77 ---- ---- ---- 1500 993 706 0.76 1033 736 0.79 1076 759 0.81 ---- ---- ---- ---- ---- ---- 1600 1024 765 0.82 1065 794 0.85 1108 818 0.88 ---- ---- ---- ---- ---- ---- 1700 1057 829 0.89 1098 859 0.92 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1091 899 0.96 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK74 blower sheave and A39 belt. AK61 blower sheave and A36 belt - Field installation required. Unitary Products Group 25 036-21687-002-A-1105 TABLE 21: SUPPLY AIR BLOWER PERFORMANCE (DJ048 BELT DRIVE) - SIDE DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.2 0.3 0.4 0.5 0.6 0.7 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 ---- ---- ---- ---- ---- ---- ---- ---- ---- 789 527 0.57 831 567 0.61 874 602 0.65 1100 ---- ---- ---- ---- ---- ---- ---- ---- ---- 811 559 0.60 854 599 0.64 896 634 0.68 1200 ---- ---- ---- ---- ---- ---- 791 548 0.59 833 592 0.63 876 632 0.68 918 667 0.72 1300 ---- ---- ---- 772 539 0.58 813 584 0.63 855 628 0.67 898 668 0.72 940 703 0.75 1400 ---- ---- ---- 795 579 0.62 836 624 0.67 878 668 0.72 920 708 0.76 963 744 0.80 1500 779 578 0.62 819 624 0.67 860 669 0.72 902 713 0.77 944 753 0.81 987 789 0.85 1600 804 629 0.67 844 675 0.72 885 720 0.77 927 764 0.82 970 804 0.86 1013 839 0.90 1700 831 685 0.74 871 731 0.78 913 777 0.83 955 820 0.88 997 861 0.92 1040 896 0.96 1800 860 748 0.80 901 794 0.85 942 839 0.90 984 883 0.95 1026 923 0.99 1069 958 1.03 1900 891 817 0.88 931 862 0.92 973 908 0.97 1015 951 1.02 1057 992 1.06 1100 1027 1.10 2000 924 891 0.96 964 937 1.01 1005 982 1.05 1047 1026 1.10 1090 1066 1.14 1133 1102 1.18 2100 959 972 1.04 999 1018 1.09 1040 1063 1.14 1082 1107 1.19 1125 1147 1.23 1167 1182 1.27 2200 996 1059 1.14 1036 1104 1.18 1077 1150 1.23 1119 1194 1.28 1162 1234 1.32 ---- ---- ---- 2300 1034 1151 1.24 1075 1197 1.28 1116 1243 1.33 1158 1286 1.38 ---- ---- ---- ---- ---- ---- 2400 1075 1250 1.34 1115 1296 1.39 1156 1341 1.44 ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1118 1354 1.45 1158 1400 1.50 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.8 0.9 1.0 1.1 1.2 1.3 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 917 631 0.68 959 651 0.70 1001 660 0.71 1041 658 0.71 1081 642 0.69 1119 611 0.66 1100 939 663 0.71 981 683 0.73 1023 692 0.74 1064 690 0.74 1103 674 0.72 1141 643 0.69 1200 961 696 0.75 1003 716 0.77 1045 725 0.78 1086 723 0.78 1125 707 0.76 1163 676 0.73 1300 983 732 0.79 1025 752 0.81 1067 761 0.82 1108 759 0.81 1147 743 0.80 1185 712 0.76 1400 1006 772 0.83 1048 792 0.85 1090 801 0.86 1130 799 0.86 1170 783 0.84 ---- ---- ---- 1500 1030 817 0.88 1072 837 0.90 1114 847 0.91 1154 844 0.91 1194 829 0.89 ---- ---- ------- 1600 1055 868 0.93 1098 888 0.95 1139 897 0.96 1180 895 0.96 ---- ---- ---- ---- ---- 1700 1083 924 0.99 1125 944 1.01 1166 954 1.02 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1112 987 1.06 1154 1007 1.08 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1142 1055 1.13 1185 1075 1.15 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1175 1130 1.21 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK61 blower sheave and A36 belt. AK56 blower sheave and A36 belt - Field installation required. 26 Unitary Products Group 036-21687-002-A-1105 TABLE 22: SUPPLY AIR BLOWER PERFORMANCE (DJ048 BELT DRIVE) - BOTTOM DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.2 0.3 0.4 0.5 0.6 0.7 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 833 564 0.61 879 605 0.65 1100 ---- ---- ---- ---- ---- ---- ---- ---- ---- 809 549 0.59 854 592 0.63 900 633 0.68 1200 ---- ---- ---- ---- ---- ---- 786 538 0.58 830 581 0.62 875 623 0.67 920 664 0.71 1300 ---- ---- ---- 766 535 0.57 808 574 0.62 851 617 0.66 896 659 0.71 942 700 0.75 1400 749 541 0.58 789 576 0.62 830 616 0.66 874 658 0.71 918 701 0.75 964 742 0.80 1500 774 587 0.63 813 622 0.67 855 662 0.71 898 705 0.76 943 747 0.80 989 788 0.85 1600 801 639 0.69 840 674 0.72 881 714 0.77 925 757 0.81 970 799 0.86 1015 840 0.90 1700 830 697 0.75 869 732 0.79 911 772 0.83 954 814 0.87 999 857 0.92 1045 898 0.96 1800 862 760 0.81 901 795 0.85 943 835 0.90 986 877 0.94 1031 920 0.99 1077 960 1.03 1900 897 828 0.89 936 863 0.93 977 903 0.97 1021 945 1.01 1066 988 1.06 1111 1029 1.10 2000 934 901 0.97 973 936 1.00 1015 976 1.05 1058 1018 1.09 1103 1061 1.14 1149 1102 1.18 2100 974 979 1.05 1013 1014 1.09 1055 1054 1.13 1098 1097 1.18 1143 1139 1.22 1189 1180 1.27 2200 1017 1063 1.14 1056 1098 1.18 1098 1138 1.22 1141 1180 1.27 1186 1223 1.31 ---- ---- ---- 2300 1063 1151 1.23 1102 1186 1.27 1144 1226 1.31 1187 1268 1.36 ---- ---- ---- ---- ---- ---- 2400 1111 1243 1.33 1151 1278 1.37 1192 1318 1.41 ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1163 1340 1.44 1202 1376 1.48 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.8 0.9 1.0 1.1 1.2 1.3 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 925 642 0.69 971 673 0.72 1017 696 0.75 1061 708 0.76 1103 708 0.76 1144 693 0.74 1100 946 670 0.72 992 701 0.75 1037 723 0.78 1082 736 0.79 1124 735 0.79 1165 721 0.77 1200 967 701 0.75 1013 732 0.79 1058 755 0.81 1102 767 0.82 1145 767 0.82 1185 752 0.81 1300 988 737 0.79 1034 768 0.82 1079 791 0.85 1123 803 0.86 1166 803 0.86 ---- ---- ---- 1400 1010 779 0.84 1056 809 0.87 1102 832 0.89 1146 844 0.91 1188 844 0.91 ---- ---- ---- 1500 1035 825 0.89 1081 856 0.92 1126 879 0.94 1170 891 0.96 ---- ---- ---- ---- ---- ---- 1600 1062 877 0.94 1108 908 0.97 1153 931 1.00 1197 943 1.01 ---- ---- ---- ---- ---- ---- 1700 1091 935 1.00 1137 966 1.04 1182 988 1.06 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1123 997 1.07 1169 1028 1.10 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1157 1066 1.14 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1195 1139 1.22 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK61 blower sheave and A36 belt. AK56 blower sheave and A36 belt - Field installation required. Unitary Products Group 27 036-21687-002-A-1105 TABLE 23: SUPPLY AIR BLOWER PERFORMANCE (DJ060 BELT DRIVE) - SIDE DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.2 0.3 0.4 0.5 0.6 0.7 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 876 632 0.68 918 667 0.72 1300 ---- ---- ---- ---- ---- ---- ---- ---- ---- 855 628 0.67 898 668 0.72 940 703 0.75 1400 ---- ---- ---- ---- ---- ---- 836 624 0.67 878 668 0.72 920 708 0.76 963 744 0.80 1500 ---- ---- ---- 819 624 0.67 860 669 0.72 902 713 0.77 944 753 0.81 987 789 0.85 1600 ---- ---- ---- 844 675 0.72 885 720 0.77 927 764 0.82 970 804 0.86 1013 839 0.90 1700 831 685 0.74 871 731 0.78 913 777 0.83 955 820 0.88 997 861 0.92 1040 896 0.96 1800 860 748 0.80 901 794 0.85 942 839 0.90 984 883 0.95 1026 923 0.99 1069 958 1.03 1900 891 817 0.88 931 862 0.92 973 908 0.97 1015 951 1.02 1057 992 1.06 1100 1027 1.10 2000 924 891 0.96 964 937 1.01 1005 982 1.05 1047 1026 1.10 1090 1066 1.14 1133 1102 1.18 2100 959 972 1.04 999 1018 1.09 1040 1063 1.14 1082 1107 1.19 1125 1147 1.23 1167 1182 1.27 2200 996 1059 1.14 1036 1104 1.18 1077 1150 1.23 1119 1194 1.28 1162 1234 1.32 ---- ---- ---- 2300 1034 1151 1.24 1075 1197 1.28 1116 1243 1.33 1158 1286 1.38 ---- ---- ---- ---- ---- ---- 2400 1075 1250 1.34 1115 1296 1.39 1156 1341 1.44 ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1118 1354 1.45 1158 1400 1.50 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR 0.8 0.9 1.0 1.1 1.2 1.3 FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1200 961 696 0.75 1003 716 0.77 1045 725 0.78 1086 723 0.78 1125 707 0.76 1163 676 0.73 1300 983 732 0.79 1025 752 0.81 1067 761 0.82 1108 759 0.81 1147 743 0.80 1185 712 0.76 1400 1006 772 0.83 1048 792 0.85 1090 801 0.86 1130 799 0.86 1170 783 0.84 ---- ---- ---- 1500 1030 817 0.88 1072 837 0.90 1114 847 0.91 1154 844 0.91 1194 829 0.89 ---- ---- ---- 1600 1055 868 0.93 1098 888 0.95 1139 897 0.96 1180 895 0.96 ---- ---- ---- ---- ---- ---- 1700 1083 924 0.99 1125 944 1.01 1166 954 1.02 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1112 987 1.06 1154 1007 1.08 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1142 1055 1.13 1185 1075 1.15 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1175 1130 1.21 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK56 blower sheave and A36 belt. 28 Unitary Products Group 036-21687-002-A-1105 TABLE 24: SUPPLY AIR BLOWER PERFORMANCE (DJ060 BELT DRIVE) - BOTTOM DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.2 0.3 0.4 0.5 0.6 0.7 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 862 453 0.49 901 498 0.53 1100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 883 494 0.53 922 539 0.58 1200 ---- ---- ---- ---- ---- ---- ---- ---- ---- 866 489 0.53 904 536 0.58 943 581 0.62 1300 ---- ---- ---- ---- ---- ---- 850 488 0.52 889 535 0.57 928 581 0.62 967 627 0.67 1400 ---- ---- ---- 836 491 0.53 875 537 0.58 913 584 0.63 952 631 0.68 991 676 0.73 1500 ---- ---- ---- 862 545 0.58 901 591 0.63 940 638 0.68 978 685 0.73 1017 730 0.78 1600 851 559 0.60 890 604 0.65 928 650 0.70 967 697 0.75 1006 744 0.80 1045 789 0.85 1700 880 624 0.67 919 668 0.72 958 714 0.77 996 761 0.82 1035 808 0.87 1074 853 0.92 1800 911 694 0.74 949 738 0.79 988 785 0.84 1027 832 0.89 1066 878 0.94 1105 923 0.99 1900 942 770 0.83 981 814 0.87 1020 860 0.92 1059 907 0.97 1097 954 1.02 1136 999 1.07 2000 976 851 0.91 1014 895 0.96 1053 941 1.01 1092 989 1.06 1130 1035 1.11 1169 1080 1.16 2100 1010 938 1.01 1049 982 1.05 1087 1028 1.10 1126 1075 1.15 1165 1122 1.20 1204 1167 1.25 2200 1046 1030 1.11 1084 1075 1.15 1123 1121 1.20 1162 1168 1.25 1200 1215 1.30 ---- ---- ---- 2300 1082 1128 1.21 1121 1172 1.26 1160 1219 1.31 1198 1266 1.36 ---- ---- ---- ---- ---- ---- 1322 1.42 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 1120 1231 1.32 1159 1276 1.37 1198 2500 1159 1340 1.44 1198 1384 1.48 ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR 0.8 0.9 1.0 1.1 1.2 1.3 FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 940 541 0.58 980 579 0.62 1019 613 0.66 1059 641 0.69 1099 662 0.71 1140 674 0.72 1100 961 582 0.62 1000 621 0.67 1040 654 0.70 1080 682 0.73 1120 703 0.75 1161 715 0.77 1200 983 624 0.67 1022 663 0.71 1062 697 0.75 1101 725 0.78 1142 745 0.80 1182 758 0.81 1300 1006 669 0.72 1045 708 0.76 1085 742 0.80 1125 770 0.83 1165 791 0.85 ---- ---- ---- 1400 1030 718 0.77 1070 757 0.81 1109 791 0.85 1149 819 0.88 1190 840 0.90 ---- ---- ---- 1500 1057 772 0.83 1096 811 0.87 1136 845 0.91 1176 873 0.94 ---- ---- ---- ---- ---- ---- 1600 1084 831 0.89 1124 870 0.93 1163 904 0.97 1203 932 1.00 ---- ---- ---- ---- ---- ---- 1700 1113 896 0.96 1153 935 1.00 1192 969 1.04 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1144 966 1.04 1183 1005 1.08 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1175 1042 1.12 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1209 1123 1.20 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK56 blower sheave and A36 belt. Unitary Products Group 29 036-21687-002-A-1105 TABLE 25: BELT DRIVE BLOWER MOTOR AND DRIVE DATA MODEL SIZE BLOWER RANGE (RPM) MOTOR1 HP FRAME ADJUSTABLE MOTOR PULLEY OUTSIDE DIA. (IN.) DESIGNATION PITCH DIA. (IN.) BELT (NOTCHED) FIXED BLOWER PULLEY BORE (IN.) DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION PITCH LENGTH (IN.) QTY. DJ036 600/920 1-1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK74 7.2 7.0 1 A39 40.3 1 DJ048 790/1120 1-1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK61 5.9 5.7 1 A36 37.3 1 DJ060 850/1220 1-1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK56 5.4 5.2 1 A36 37.3 1 1. All motors have solid bases and are inherently protected. These motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. TABLE 26: STATIC RESISTANCES RESISTANCE, IWG DESCRIPTION CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 7-15KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20-30KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.23 0.26 0.29 0.32 ECONOMIZER1,3 ELECTRIC HEATERS1 COOLING ONLY2 1. Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables. 2. Add these resistance values to the available static resistance values on SUPPLY AIR BLOWER PERFORMANCE Tables. 3. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. TABLE 27: ELECTRIC HEATER CFM LIMITATIONS MINIMUM SUPPLY AIR CFM UNIT MODEL SIZE NOMINAL TONS VOLTAGE HEATER SIZE NOMINAL KW 5 7 10 15 20 30 208/230-1-60 1100 1100 1200 1200 1300 - 208/230-3-60 1100 1100 1200 1200 1300 - 460-3-60 - 1100 1200 1200 1300 - 575-3-60 - - 1200 1200 1300 - 208/230-1-60 1300 1300 1300 1300 1300 - 208/230-3-60 1300 1300 1300 1300 1300 - 460-3-60 - 1300 1300 1300 1300 - 575-3-60 - - 1300 1300 1400 - 208/230-1-60 1600 1600 1600 1600 1600 1600 208/230-3-60 1600 1600 1600 1600 1600 1600 460-3-60 1600 1600 1600 1600 1600 1600 575-3-60 - 1600 1600 1600 1600 1800 3 4 5 30 Unitary Products Group 036-21687-002-A-1105 TABLE 28: ELECTRICAL DATA - DJ036, 048 & 060 BELT DRIVE W/O POWERED CONVENIENCE OUTLET COMPRESSORS MODEL TONNAGE VOLTAGE RLA EACH LRA EACH OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA 208-1-60 11.3 68.0 2.3 7.6 0.0 230-1-60 11.3 68.0 2.3 7.6 0.0 208-3-60 8.3 68.0 2.3 5.2 0.0 230-3-60 8.3 68.0 2.3 5.2 0.0 460-3-60 5.1 34.0 1.3 2.6 0.0 575-3-60 3.2 26.0 1.3 2.0 0.0 208-1-60 15.4 86.0 2.3 7.6 0.0 230-1-60 15.4 86.0 2.3 7.6 0.0 208-3-60 11.5 84.0 2.3 5.2 0.0 230-3-60 11.5 84.0 2.3 5.2 0.0 460-3-60 5.8 42.0 1.3 2.6 0.0 575-3-60 5.1 34.0 1.3 2.0 0.0 DJ036 DJ048 Unitary Products Group ELECTRIC HEATER HEATER HEATER MODEL NO. KW AMPS None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 None 2CE04511058 2CE04511558 2CE04512058 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 None 2CE04511058 2CE04511558 2CE04512058 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -6.8 10.1 13.6 19.5 -10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -6.8 10.1 13.6 19.5 -10.6 15.9 21.2 -19.2 26.9 38.5 57.2 76.4 -22.1 31.3 44.2 66.3 88.3 -11.1 15.5 22.2 33.0 44.1 -12.7 18.0 25.5 38.2 51.0 -8.2 12.1 16.4 23.5 -10.2 15.3 20.4 -19.2 26.9 38.5 57.2 76.4 -22.1 31.3 44.2 66.3 88.3 -11.1 15.5 22.2 33.0 44.1 -12.7 18.0 25.5 38.2 51.0 -8.2 12.1 16.4 23.5 -10.2 15.3 20.4 MIN. MAX. FUSE/ BRKR1 CIRCUIT SIZE AMPACITY (AMPS) (AMPS) 24.0 30 33.5 35 43.2 45 57.6 60 81.0 90 105.1 110 24.0 30 37.1 40 48.6 50 64.7 70 92.3 100 119.9 125 17.9 25 20.4 25 25.9 30 34.3 35 47.8 50 61.7 70 17.9 25 22.4 25 29.1 30 38.4 40 54.3 60 70.2 80 10.3 15 13.5 15 18.4 20 23.7 25 32.6 35 7.0 15 15.2 20 21.6 25 28.0 30 29.1 35 33.5 40 43.2 45 57.6 60 81.0 90 105.1 110 29.1 35 37.1 40 48.6 50 64.7 70 92.3 100 119.9 125 21.9 30 21.9 30 25.9 30 34.3 35 47.8 50 61.7 70 21.9 30 22.4 30 29.1 30 38.4 40 54.3 60 70.2 80 11.1 15 13.5 15 18.4 20 23.7 25 32.6 35 9.4 15 15.2 20 21.6 25 28.0 30 31 036-21687-002-A-1105 TABLE 28: ELECTRICAL DATA - DJ036, 048 & 060 BELT DRIVE W/O POWERED CONVENIENCE OUTLET (CONT) COMPRESSORS MODEL TONNAGE VOLTAGE RLA EACH LRA EACH OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA 208-1-60 25.0 150.0 2.3 7.6 0.0 230-1-60 25.0 150.0 2.3 7.6 0.0 208-3-60 17.3 123.0 2.3 5.2 0.0 230-3-60 17.3 123.0 2.3 5.2 0.0 460-3-60 8.4 70.0 1.3 2.6 0.0 575-3-60 7.0 53.0 1.3 2.0 0.0 DJ060 ELECTRIC HEATER HEATER HEATER MODEL NO. KW AMPS None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 2CE045130462 None 2CE04511058 2CE04511558 2CE04512058 2CE04513058 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -6.8 10.1 13.6 19.5 28.8 -10.6 15.9 21.2 30.4 -19.2 26.9 38.5 57.2 76.4 106.7 -22.1 31.3 44.2 66.3 88.3 123.3 -11.1 15.5 22.2 33.0 44.1 61.6 -12.7 18.0 25.5 38.2 51.0 71.2 -8.2 12.1 16.4 23.5 34.6 -10.2 15.3 20.4 29.3 MIN. MAX. FUSE/ CIRCUIT BRKR1 SIZE AMPACITY (AMPS) (AMPS) 41.2 45 41.2 45 43.2 60 57.6 60 81.0 90 105.1 110 142.9 150 41.2 45 41.2 45 48.6 60 64.7 70 92.3 100 119.9 125 163.7 175 29.1 35 29.1 35 29.1 35 34.3 45 47.8 50 61.7 70 83.5 90 29.1 35 29.1 35 29.1 35 38.4 45 54.3 60 70.2 80 95.5 100 14.4 20 14.4 20 18.4 20 23.7 25 32.6 35 46.6 50 11.8 15 15.2 20 21.6 25 28.0 30 39.1 40 1. HACR Type per NEC. 2. These electric heaters do not include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB0470086 are available for field installation. 32 Unitary Products Group 036-21687-002-A-1105 TABLE 29: ELECTRICAL DATA - DJ036, 048 & 060 BELT DRIVE WITH POWERED CONVENIENCE OUTLET COMPRESSORS MODEL TONNAGE VOLTAGE RLA EACH LRA EACH OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA 208-1-60 11.3 68.0 2.3 7.6 10.0 230-1-60 11.3 68.0 2.3 7.6 10.0 208-3-60 8.3 68.0 2.3 5.2 10.0 230-3-60 8.3 68.0 2.3 5.2 10.0 460-3-60 5.1 34.0 1.3 2.6 5.0 575-3-60 3.2 26.0 1.3 2.0 4.0 208-1-60 15.4 86.0 2.3 7.6 10.0 230-1-60 15.4 86.0 2.3 7.6 10.0 208-3-60 11.5 84.0 2.3 5.2 10.0 230-3-60 11.5 84.0 2.3 5.2 10.0 460-3-60 5.8 42.0 1.3 2.6 5.0 575-3-60 5.1 34.0 1.3 2.0 4.0 DJ036 DJ048 Unitary Products Group ELECTRIC HEATER HEATER HEATER MODEL NO. KW AMPS None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 None 2CE04511058 2CE04511558 2CE04512058 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 None 2CE04511058 2CE04511558 2CE04512058 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -6.8 10.1 13.6 19.5 -10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -6.8 10.1 13.6 19.5 -10.6 15.9 21.2 -19.2 26.9 38.5 57.2 76.4 -22.1 31.3 44.2 66.3 88.3 -11.1 15.5 22.2 33.0 44.1 -12.7 18.0 25.5 38.2 51.0 -8.2 12.1 16.4 23.5 -10.2 15.3 20.4 -19.2 26.9 38.5 57.2 76.4 -22.1 31.3 44.2 66.3 88.3 -11.1 15.5 22.2 33.0 44.1 -12.7 18.0 25.5 38.2 51.0 -8.2 12.1 16.4 23.5 -10.2 15.3 20.4 MIN. MAX. FUSE/ CIRCUIT BRKR1 SIZE AMPACITY (AMPS) (AMPS) 34.0 45 46.0 50 55.7 60 70.1 80 93.5 100 117.6 125 34.0 45 49.6 50 61.1 70 77.2 80 104.8 110 132.4 150 28.3 35 32.9 35 38.4 40 46.8 50 60.3 70 74.2 80 28.3 35 34.9 40 41.6 45 50.9 60 66.8 70 82.7 90 15.3 20 19.7 20 24.7 25 29.9 30 38.8 40 11.2 15 20.2 25 26.6 30 33.0 35 39.1 50 46.0 50 55.7 60 70.1 80 93.5 100 117.6 125 39.1 50 49.6 50 61.1 70 77.2 80 104.8 110 132.4 150 31.9 40 32.9 40 38.4 40 46.8 50 60.3 70 74.2 80 31.9 40 34.9 40 41.6 45 50.9 60 66.8 70 82.7 90 16.1 20 19.7 20 24.7 25 29.9 30 38.8 40 13.4 15 20.2 25 26.6 30 33.0 35 33 036-21687-002-A-1105 TABLE 29: ELECTRICAL DATA - DJ036, 048 & 060 BELT DRIVE WITH POWERED CONVENIENCE OUTLET (CONT) COMPRESSORS MODEL TONNAGE VOLTAGE RLA EACH LRA EACH OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA 208-1-60 25.0 150.0 2.3 7.6 10.0 230-1-60 25.0 150.0 2.3 7.6 10.0 208-3-60 17.3 123.0 2.3 5.2 10.0 230-3-60 17.3 123.0 2.3 5.2 10.0 460-3-60 8.4 70.0 1.3 2.6 5.0 575-3-60 7.0 53.0 1.3 2.0 4.0 DJ060 ELECTRIC HEATER HEATER HEATER MODEL NO. KW AMPS None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 2CE045130462 None 2CE04511058 2CE04511558 2CE04512058 2CE04513058 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -6.8 10.1 13.6 19.5 28.8 -10.6 15.9 21.2 30.4 -19.2 26.9 38.5 57.2 76.4 106.7 -22.1 31.3 44.2 66.3 88.3 123.3 -11.1 15.5 22.2 33.0 44.1 61.6 -12.7 18.0 25.5 38.2 51.0 71.2 -8.2 12.1 16.4 23.5 34.6 -10.2 15.3 20.4 29.3 MIN. MAX. FUSE/ CIRCUIT BRKR1 SIZE AMPACITY (AMPS) (AMPS) 51.2 70 51.2 70 55.7 70 70.1 80 93.5 100 117.6 125 155.4 175 51.2 70 51.2 70 61.1 70 77.2 80 104.8 110 132.4 150 176.2 200 39.1 50 39.1 50 39.1 50 46.8 50 60.3 70 74.2 80 96.0 100 39.1 50 39.1 50 41.6 50 50.9 60 66.8 70 82.7 90 108.0 110 19.4 25 19.7 25 24.7 25 29.9 30 38.8 40 52.8 60 15.8 20 20.2 25 26.6 30 33.0 35 44.1 45 1. HACR Type per NEC. 2. These electric heaters do not include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block accessories 2FB04700825 and 2FB0470086 are available for field installation. 34 Unitary Products Group 036-21687-002-A-1105 TABLE 30: PHYSICAL DATA DJ MODELS EVAPORATOR BLOWER 036 048 060 Centrifugal Blower (Dia. x Wd. in.) 12 X 10 12 X 10 12 X 10 Fan Motor HP (Belt Drive) 1-1/2 1-1/2 1-1/2 Rows Deep 3 4 4 Fins Per Inch 13 13 13 Face Area (Sq. Ft.) 5.1 5.1 5.1 Propeller Dia. (in.) 24 24 24 Fan Motor Hp 1/2 1/2 1/2 4200 EVAPORATOR COIL CONDENSER FANS Nom. CFM 4200 4200 Rows Deep 2 2 2 Fins Per Inch 18 18 18 Face Area (Sq. Ft.) 17.1 17.1 17.1 Quantity 1 1 1 Type Recip. Recip. Scroll Quantity Per Unit (15” X 20” X 1” or 2“) 2 2 2 Quantity Per Unit (14” X 25” X 1” or 2“) 1 1 1 Total Face Area (sq. ft.) 6.3 6.3 6.3 Refrigerant 22 (lbs./oz.) 9/4 9/8 11/0 CONDENSER COILS COMPRESSOR (Qty. Per Unit) AIR FILTERS CHARGE TABLE 31: ELECTRIC HEAT CORRECTION FACTORS NOMINAL VOLTAGE VOLTAGE kW CAP. MULTIPLIER TABLE 32: VOLTAGE LIMITATIONS1 VOLTAGE POWER SUPPLY MIN. MAX. 208/230-1-60 187 252 208 208 1.00 240 230 0.92 208/230-3-60 187 252 480 460 0.92 460-3-60 432 504 600 575 0.92 575-3-60 540 630 1. Utilization Range “A” in accordance with ARI Standard 110. Unitary Products Group 35 036-21687-002-A-1105 TYPICAL POWER WIRING REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTECTION AND WIRING. TYPICAL CONTROL WIRING COOLING / HEATING (24 VOLT THERMOSTAT) COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT 1 TERMINALS THERMOSTAT1 UNIT TERMINAL TERMINALS STRIP TB1 ADD JUMPER R RV UNIT TERMINAL STRIP TB1 RC R Y Y1 24 VOLT TRANSFORMER Y1 YC RH 24 VOLT TRANSFORMER Y2 Y2 W W1 G GF W2 C 1 G C 24 VOLT THERMOSTAT 2TH07701024. TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THE THERMOSTAT 2TH0401224. 1 COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTAT1 TERMINALS ADD JUMPER RC UNIT TERMINAL STRIP TB1 RH R Y1 Y1 2 Y2 W1 4 ADD JUMPER C LED 1 X NOT USED RH ADD JUMPER OCC A1 T TO REMOTE SENSOR 2TH040702224 IF USED 2 SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER. 3 SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER OR 2 STAGE GAS HEAT. RC R Y Y1 W W1 G G 24 VOLT TRANSFORMER A2 ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET04700224 (INCLUDES SUBBASE). UNIT TERMINAL STRIP TB1 C 4 1 4 THERMOSTAT1 TERMINALS 24 VOLT TRANSFORMER W2 G T 1 ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET07701024 (INCLUDES SUBBASE). TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THERMOSTAT 2TH04700224. REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR P6 ON UNITS WITH ECONOMIZER. TERMINALS A1 AND A2 PROVIDE A RELAY OUT-PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SET-BACK POSITION. FIGURE 2 - 36 3 B COM COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE Y2 G LED 2 24 VOLT THERMOSTAT 2ET07701024. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT 2TH0471024. W1 W2 G TYPICAL FIELD POWER & CONTROL WIRING Unitary Products Group 036-21687-002-A-1105 FIGURE 3 - UNIT DIMENSIONS (3 - 5 TON COOLING ONLY/ELECTRIC HEAT) FRONT VIEW FIGURE 4 - UNIT DIMENSIONS (3 - 5 TON COOLING/GAS HEAT) FRONT VIEW Unitary Products Group 37 036-21687-002-A-1105 DETAIL “A” FIGURE 5 - UNIT WITH ECONOMIZER RAINHOOD DETAIL “B” FIGURE 6 - 38 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD Unitary Products Group 036-21687-002-A-1105 FIGURE 7 - UNIT DIMENSIONS (REAR VIEW) 1. Opening in the bottom to the unit can be located by the side in the insulation. 2. Do not remove the 2” knockout ring. FILTER ACCESS BLOWER MOTOR ACCESS TABLE 34: MINIMUM CLEARANCES DOT PLUGS FIELD-SUPPLIED DISCONNECT SWITCH LOCATION MOUNTING BRACKET FOR DICONNECT SWITCH (Shipped attached to the blower housing inside the blower compartment) A,B WIRING ENTRY (See Detail “B”) CONTROL BOX ACCESS DISCONNECT SWITCH LOCATION AND MOTOR ACCESS PANEL FOR UNIT WITH “BELT-DRIVE” OPTION FIGURE 8 - DISCONNECT/BLOWER ACCESS LOCATION TABLE 33: UTILITIES ENTRY HOLE OPENING SIZE (DIA.) USED FOR Side A 7/8” KO1 Control Wiring2 B 2” KO1 Power Wiring C 1-5/8” KO Gas Piping (Front) D 1-1/2” KO Gas Piping (Bottom) Unitary Products Group Bottom Side LOCATION CLEARANCE Front 24” (Cooling/Electric Heat) 32” (Gas Heat) Rear 12” (Less Economizer) 36” (With Economizer or Fixed Air/Motorized Damper) Left Side (Filter Access) 24” (Less Economizer) 36” (With Economizer) Right Side (Cond. Coil) 24” Below Unit1 0” Above Unit2 72” (For Condenser Air Discharge) 1. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. Bottom 39 036-21687-002-A-1105 FIGURE 9 - 40 TYPICAL APPLICATIONS Unitary Products Group 036-21687-002-A-1105 BACK OF UNIT A 447/8 BACK OF UNIT A 447/8 821/4 821/4 D B F X X B APPROXIMATE CENTER OF GRAVITY CONDENSER COIL END OF UNIT C Y FRONT OF UNIT C E APPROXIMATE CENTER OF GRAVITY CONDENSER COIL END OF UNIT D Y FRONT OF UNIT FIGURE 10 - FOUR AND SIX POINT LOADING TABLE 35: DJ 4 AND 6 POINT LOADS WEIGHT DISTRIBUTION UNIT TOTAL 4-Point Loading (lb) 6-Point Loading (lb) A B C D A B C D E F DJ036 Cooling/ Electric 575 132 125 155 164 89 85 82 102 106 110 DJ036N04 615 141 133 166 175 95 91 88 110 114 118 DJ036D06 625 143 135 168 178 96 93 89 111 115 120 DJ036N08 635 145 138 171 181 98 94 91 113 117 122 DJ036D10 645 148 140 174 184 99 96 92 115 119 124 DJ048 Cooling/ Electric 585 134 127 158 167 90 87 84 104 108 112 DJ048(D,N)06 635 145 138 171 181 98 94 91 113 117 122 DJ048(D,N)10 655 150 142 177 187 101 97 94 117 121 125 DJ060 Cooling/ Electric 590 135 128 159 168 91 88 84 105 109 113 DJ060D06 640 147 139 173 182 99 95 92 114 118 123 DJ060N08 650 149 141 175 185 100 97 93 116 120 125 DJ060(D,N)10 660 151 143 178 188 102 98 95 118 122 126 TABLE 36: CENTER OF GRAVITY DIMENSION 3 - 5 TON X 40” Y 20” Unitary Products Group 41 036-21687-002-A-1105 TABLE 37: OPERATING WEIGHTS (LBS.) MODEL SIZE 3 TON 4 TON 5 TON 575 585 590 N04 615 - - N06 - 635 - N08 635 - 650 DJ (Cooling Only) BASIC UNIT DJ (Gas/Electric) N10 - 655 660 D06 625 635 640 D10 645 655 660 Economizer 50 Motorized Damper OPTIONS Electric Heater 26 5 - 7 kW 18 10 - 15 kW 23 20 - 30 kW ACCY. 28 Roof Curb 92 Barometric Relief / Fixed Air Damper 10 FIGURE 11 - ROOF CURB DIMENSIONS 42 Unitary Products Group 036-21687-002-A-1105 GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility. York's Sunline Magnum™ units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory-mounted options and field-installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non-Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch.The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5-year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat and designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. Coils: a. Evaporator and condenser coils shall have alumi- Unitary Products Group UNIT CABINET Unit cabinet shall be constructed of G90 galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2” thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be “large” size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air bypass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards. Condensate connection shall be a minimum of 3/4” I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed belt drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. REFRIGERANT COMPONENTS Compressor: a. Shall be internally protected with internal high-pressure relief and over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. num plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints 43 036-21687-002-A-1105 brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator and Condenser coils shall be of the direct expansion, draw-thru, design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed-orifice or thermally operated expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The refrigeration system shall provide at least 15°F of sub-cooling at design conditions. GAS HEATING SECTION (SINGLE OR 2 STAGE) Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: UNIT CONTROLS a. 44 Unit shall be complete with self-contained low-voltage control circuit protected by a resetable circuit breaker on the 24-volt transformer side. a. Primary and auxiliary high-temperature limit switches. b. Induced draft motor speed sensor. c. Flame roll out switch. d. Flame proving controls. ELECTRIC HEATING SECTION An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 30 KW, offering two stages of capacity - 16 KW and above on 208/230 volt heaters and 20 KW and above on 460 and 575 volt heaters. The heating section shall have a primary limit control(s) and automatic reset to prevent the heating element system from operating at an excessive temperature. The heating section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating shall be wired for a single point power supply with branch circuit fusing (where required). b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze-protection thermostat, evaporator coil. f. If any of the above safety devices trip, a LED (lightemitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. g. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. h. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. i. Unit control board shall have on-board diagnostics and fault code display. ELECTRICAL REQUIREMENTS j. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0°F. k. Control board shall monitor each refrigerant safety switch independently. All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. l. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. UNIT OPERATING CHARACTERISTICS a. Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). STANDARD LIMITED WARRANTIES • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year Unitary Products Group 036-21687-002-A-1105 OPTIONAL OUTDOOR AIR (Shall be made available by either/or): • • ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER- Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, spring return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed-air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. MOTORIZED OUTDOOR AIR DAMPERS - Outdoor air dampers are positioned by a 2-position, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions - regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. • HIGH ALTITUDE - PROPANE GAS - Contains orifices required for applications between 2000 and 6000 feet altitude. Must be used with propane conversion kit. • LOW NOX - Required to reduce the emission of nitrogen oxides below 40 nanograms per joule. • GAS PIPING - Contains 1/2” pipe nipples, fittings and gas cock (including panel assess gaskets) required for bottom gas supply connection with external shut off. • POWER EXHAUST OPTION - To work in conjunction with economizers. • ELECTRIC HEATERS • ECONOMIZER/MOTORIZED DAMPER RAIN HOOD Contains all hood panels and the hardware for assembling. • MANUAL OUTDOOR AIR DAMPER • COIL GUARD KIT - Guard for cooling coil. • HAIL GUARD • FLUE EXHAUST EXTENSION OTHER FACTORY INSTALLED OPTIONS • POWER EXHAUST OPTION - To work in conjunction with economizers. • STAINLESS STEEL HEAT EXCHANGER • STAINLESS STEEL DRAIN PAN • BOTTOM DRAIN CONNECTION • TECHNICOAT PHENOLIC COATED CONDENSER AND EVAPORATOR COIL • ELECTRONIC SINGLE ENTHALPY ECONOMIZER • DIRTY FILTER SWITCH • PHASE MONITOR • COIL GUARD OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE • POWERED GFI CONVENIENCE OUTLET ROOF CURB - 14"and 8” high, full perimeter curb with wood nailer (shipped knocked-down). • NON-POWERED GFI CONVENIENCE OUTLET • BAS CONTROLS (Simplicity™ INTELLI-Comfort™, CPC, JOHNSON, HONEYWELL, NOVAR) • BAS READY ECONOMIZER (BELIMO ACTUATOR WITHOUT A CONTROLLER) • HINGED FILTER DOOR ACCESS AND TOOLESS ACCESS PANELS • 2" PLEATED FILTERS • DISCONNECT SWITCH • SUPPLY AIR SMOKE DETECTOR • RETURN AIR SMOKE DETECTOR • • • • BAROMETRIC RELIEF DAMPER - Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit. PROPANE CONVERSION KIT - Contains new orifices and gas valve parts to convert from natural to L.P. gas. One per unit required. HIGH ALTITUDE - NATURAL GAS - Contains orifices required for applications between 2000 and 6000 feet altitude. Unitary Products Group 45 036-21687-002-A-1105 46 Unitary Products Group 036-21687-002-A-1105 Unitary Products Group 47 Subject to change without notice. Printed in U.S.A. Copyright © 2005 by Unitary Products Group. All rights reserved. Unitary Products Group 5005 York Drive 036-21687-002-A-1105 Supersedes: 036-21687-001-A-0605 Norman OK 73069 ">
Advertisement
Key Features
- Convertible air discharge (bottom or side)
- Common cabinet and roof curb design
- Simplicity Control Board
- Comprehensive warranties
- Permanently lubricated motors
- ISO9001 quality standards
- ASTM-B-117 salt spray tested finish
Frequently Answers and Questions
What are the nominal tonnage options for these units?
3, 4, and 5 tons.
What is the SEER rating of these units?
13.40 to 13.50 SEER.
What type of warranty is provided on the compressor?
A five-year parts warranty on the compressor.
What type of warranty is provided on the gas-fired heat exchangers?
A ten-year parts warranty on the gas-fired heat exchangers.