Manager Guide Indications on the system Using System

Manager Guide Indications on the system Using System
10 Zone LED Alarm Panel -Manager Guide
Manager Guide
This User Guide tells you how to operate your intruder alarm system. To simplify this User Guide
we have assumed that the alarm system has been installed by a professional intruder alarm system
installer (the installer), and that the system is operated in a “typical” way. Aspects of you system
that are not “typical” will be described by your installer.
NOTE: If you have any questions about your intruder alarm system, then consult your installer,
see contact details at the front of this User Guide.
Indications on the system
Indications
LED steady on indication
LED flashing indication
LED off
Internal Sound
External Device: Strobe
External Siren: Bell
Using System
After you had finish system setting, you can use the system now. This section gives an operation
of how to set and unset the system as well as how to reset after an alarm.
1
10 Zone LED Alarm Panel -Manager Guide
Table of Contents
MANAGER GUIDE..............................................................................................................1
INDICATIONS ON THE SYSTEM .......................................................................................1
USING SYSTEM..................................................................................................................1
TABLE OF CONTENTS ......................................................................................................2
How to Set the System ....................................................................................................................3
How to OMIT a zone(s) ..................................................................................................................4
Unsetting the System.......................................................................................................................4
How to UNSET from Alarm and RESET the system...................................................................5
How to use Panic Alarm on keypad...............................................................................................5
How to Set up the system................................................................................................................5
How to go into Manager Program Mode ......................................................................................6
1 = Setup Codes ............................................................................................................................6
2 = View Event Log ......................................................................................................................8
3 = How to Authorize engineer access..........................................................................................9
4 = How to set Chime Zone ..........................................................................................................9
9 = Test System ...........................................................................................................................10
How to Exit Manager Program Menu......................................................................................... 11
2
10 Zone LED Alarm Panel -Manager Guide
How to Set the System
Full Set
When you leave your premises you will need to set (or turn on) the intruder alarm system.
Before setting the system you should ensure that the premises have been completely vacated and
that all doors and windows are closed. Ensure that pets do not have access to the protected areas as
they can cause a false alarm.
Part Set
If your installer has programmed your system for PART SET operation you will be able to set
some zones of the system while others remain unset. Part set operation is often used at night time,
and it will permit you to free walk around the bedrooms while the living are and outside doors are
protected. Your system may have 2 part-set programs called Part 1 and Part 2 .
Before Part-setting the system you should ensure that all doors and windows are closed. Ensure
that pets do not have access to the protected areas. Your installer may have instructed you to use a
different keypad to the one normally used to set the system.
Note: · There will be no exit beeps if Silent Exit mode was programmed.
· You should wait until you hear that the exit beep has stopped before assuming that the
system has set.
·System is in Day mode and supply power 1 minute
later.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·Enter User code/Manager code ? ? ?
Day LED will flash 5 second, then you can
select arm mode.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
9 10
Day
PA
TAMP
·Press
Or press
Or press
Or press
?
key to select Full arm mode,
OMT
I key to select Part 1 arm mode,
key to select Part 2 arm mode.
&
RESET key to exit.
SET
·If it has faults in system, you can see the fault
from LED and the fault tone will be generated,
you should to solve the fault to entry the mode
e.g. Detect 1 abnormal.
Exit error beep
·Press
SET
key quick set the system.(Optional)
Count down beep
·After you selected arm mode, Day LED became
steady. And will go out when armed.
3
1 2
3 4 5
6 7 8
10 Zone LED Alarm Panel -Manager Guide
How to OMIT a zone(s)
If you cannot set the alarm system because a detector is faulty and in constant alarm you may need
to omit is zone from the alarm system. A zone which has been omitted cannot cause an alarm.
Omitted zones will be restored after the system is unset.
Before a zone can be omitted it has to be enabled by the engineer as “Setup zone attrs/Omit
Allowed” zone.
·System work in setting mode, add the set mode
is chosen.( for more information see
“How to Setting the System”)
·Press OMT
I key to go into omit zone window,
and all omit allowed zone is lit.
e.g. To omit zone 4
Press 4 to omit zone 4, the corresponding LED OFF.
Press same key to toggle ON/OFF.
Note: 1-9 key= zone1 –zone 9, 0 key = zone 10.
·Press SET key to accept and continue setting
or press RESET key to cancel omit function.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
·System work in setting mode
Unsetting the System
When you enter your premises you will need to unset (turn off) the system.
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
·System is in Set mode.
·Enter User code/Manager code
System returns to Day mode.
?
?
?
?
CAUTION: Entering an invalid user code will operate the code tamper. After 9 incorrect keys
pushes a full alarm condition will be generated.
4
10 Zone LED Alarm Panel -Manager Guide
How to UNSET from Alarm and RESET the system
You can unset the system in SET and reset it after an alarm, Tamper or PA.
The system will be programmed to be reset by the user or engineer. This is dependent on System
flags set up. See Engineer mode / Setup System/ Flags 1.
e.g. Zone 3 trigger alarm
·System is in Set mode.
·Enter User code/Manager code ? ? ? ?
It will stop system in alarm and the LED keypad will
hint of alarm event. First event is flashing, other lit.
·Enter User code/Manager code
System returns to Day mode.
?
?
?
?
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
How to use Panic Alarm on keypad
Should you need to attract attention, the full alarm signal can be activated at emergency by
pressing 0 and 5 together
Press 0 & 5 simultaneously, the system and external sounder will sound immediately.
How to Set up the system
The manage mode which is the high authority has the part function of the whole system. The
Manager structure is shown in the following table:
MENU OPTIONS
1 Set up codes
2 View alarm log
3 Authorize Engineer access
& Set up Chime
9 Test System
Note: LED Remote keypad
&
Set Chime Zone.
5
10 Zone LED Alarm Panel -Manager Guide
How to go into Manager Program Mode
·System work in Day mode
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·Go into Manager Menu.
Press PROG 0 1 2 3
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 = Setup Codes
There are 2 user codes can be set in the system .All are 4-digit and can be set to any number from
0000 to 9999. The access codes ensure that only authorized users can operate the system.
1 = user 1, 2 = user 2, 3 = Holiday,4 = Engineer, 6 = Manager .
User 1 – User2 codes:
The user 1 –user 2 codes have the same operation for testing and Setting and Unsetting,
changing their own code.
Holiday code:
The purpose of this code is to allow access to the property whilst the manager is absent. The
Holiday access code is programmed by the Manager and is only valid until the manager use’s
the system. At this point the Holiday code becomes invalid and is no longer accepted by the
control panel.
Manager code
The operate the alarm system you will need to use a code. A code is 4 digits long, and
can be any number from 0000 to 9999. By default manager code is 0 1 2 3
but
you should change this as soon as possible.
NOTE: Entering an invalid user code 4 times will operate the code tamper and lock you out.
After another 5 times invalid user code , a full alarm condition will be generated.
6
10 Zone LED Alarm Panel -Manager Guide
How to change User Code
This option allows each of the users to be given a code.
Under Manager Menu.
·Press 1 to select Setup User codes.
·Press
1 to change User 1.
·Enter the new user 1 code (4 digits)
? ? ? ? New code
·Press PROG key to save. If the 4-digit is the same
as old, the error tone will be generated.
·Press RESET key will cancel and return.
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
How to delete User Code
Under Manager Menu.
·Press 1 to select Setup User codes.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·Press 1 to change User 1.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·Press
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
OI
MT
key to delete user 1 code.
7
10 Zone LED Alarm Panel -Manager Guide
2 = View Event Log
The event log gives a display of all the events that have taken place. The events are arranged by
date and time. Up to 16 events can be stored in the memory. When the log reaches 16 events and
another event takes place, the first event drops out. The system is known as FILO (First In Last
Out).
To view the event log:
Press:
1
2
3
4
9
Jump to oldest event
Move one event older
Move one event newer
Jump to newest event
Clear all alarm event
After selecting Alarm Log the zone, PA and Tamper LED’s will show the latest event
A flashing LED indicates the zone that was first activated.
Any other LED lit was activated after the first event but before system unset.
Under Manager Menu.
·Press
2 key to select view alarm event.
LED 1flashing indicate Zone 1 is triggered first.
TAMPER is triggered after Zone 1
·Press
RESET
1 2
9 10
Day
PA
TAMP
7 8 9 10
Day
PA
TAMP
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
3 4 5
1 2 3
to leave view alarm log menu.
4 5
6 7 8
6
How to clear all alarm events?
Under Manager Menu.
·Press
2 key to select view alarm event.
·Press 9 to clear all alarm events.
System all LEDs would be dark and emit
a confirm sound to indicate clear all alarm event.
Acknowledge
·Press
RESET
to leave view alarm log menu.
1 2
8
3 4 5
6 7 8 9 10
Day
PA
TAMP
10 Zone LED Alarm Panel -Manager Guide
3 = How to Authorize engineer access
You should require the manager to authorize Engineer access. It is accessed directly form Day
mode via the Engineer code.
·Enter Manager program mode.
·Press PROG 0 1 2 3
·Press 3 to authorize Engineer access.
Then Engineer can access program mode
within 3hr hour.
·Press to
RESET
leave the current menu.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
4 = How to set Chime Zone
If a Security Zone is programmed as Chime, you can hear special tone when it is triggered in
DAY mode.
Note: The zone must be set to security for chime to be set.
·Under Manager mode
·Press & key go into Set Chime Zone function.
And zone 3 LED ON indicates the zone set chime.
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
e.g. Set Zone1, 4 have Chime function.
·Press 3 key cannel zone 3 chime.
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
·Press
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1 2
3 4 5
6 7 8
9 10
Day
PA
TAMP
1
4 keys to select Chime zone.
·Press PROG to accept the change.
Or press RESET to cancel.
9
10 Zone LED Alarm Panel -Manager Guide
9 = Test System
This function has three parts in Test System: Test output, Walk Test, View Walk Test.
How to Test Outputs
The test outputs are: 0 = BELL, 1 = Strobe, 2 = Speaker,
Under Manager Menu.
·Press 9 key to Select Test System.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·Press 0 key to select Bell test.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
6 7 8 9 10
Day
PA
TAMP
6 7 8 9 10
Day
PA
TAMP
Bell on
·Press 1 key to select Strobe test.
1 2 3 4 5
Strobe on
·Press 2 key to select Speaker test.
1 2 3 4 5
Alarm sound
·Press
RESET
1 2 3 4 5
key to exit current level.
10
6 7 8 9 10
Day
PA
TAMP
10 Zone LED Alarm Panel -Manager Guide
How to enter Walk Test
The walk test function allows check each Zone trigger, Zone tamper, Detector Tamper, Control
panel tamper, BellBox tamper, Remote Keypad tamper. if order to verify that they are functioning
correctly. A tone is generated as each zone or tamper is activated (opened).
e.g. Trigger zone 1, zone 1 tamper, Control panel tamper.
Under Manager Menu.
·Press 9 key to Select Test System.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·Press 8 key to select Walk test.
Trigger zone 1, when a zone is successfully tested,
the LED is on, Zones are added to list as each one
is activated.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·Trigger zone 1 tamper and its appropriate led will
light.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·The Tamper LED comes on when tested.
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
·Press
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
1 2 3 4 5
6 7 8 9 10
Day
PA
TAMP
RESET
key to exit current level.
How to Exit Manager Program Menu
Under Manager Menu.
RESET key return to top of manager menu.
·Press
·Press
key to exit manager program mode,
return to Day mode, and two accept beep sound
are heard .
RESET
11
PRM-M-HERCULES-LEDCP-MANAGER
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement