Assembly Instruction - Grundig SAT Systems

Add to My manuals
10 Pages

advertisement

Assembly Instruction - Grundig SAT Systems | Manualzz

SID 162

C ontents

1 Safety regulations ..............................................................................................3

2 General information ..........................................................................................3

2.1 Scope of delivery ............................................................................... 3

2.2 Meaning of the symbols used ............................................................... 4

2.3 Technical data.................................................................................... 4

2.4 Description ........................................................................................ 4

3 Overview ..........................................................................................................5

4 Installing the SAT IF input distributor ...................................................................6

5 Connecting the SAT IF input distributor ................................................................7

5.1 Connecting the HF connections ............................................................ 7

Using one reception area (loop-through mode) ....................................... 7

Using two reception areas ................................................................... 7

5.2 Connecting the power supply ............................................................... 8

6 Final procedures ................................................................................................9

- 2 - SID 162

1 s afety regulations

• The standards IEC/EN/DIN EN 50083 resp. IEC/EN/DIN EN 60728 must be observed.

• Do not perform installation and service work during thunderstorms.

• Assembly, installation and servicing should be carried out by authorised electricians.

• Switch off the operating voltage of the system before beginning with assembly or service work.

• Avoid short circuits!

• Observe the relevant standards, regulations and guidelines on the installation and operation of antenna systems.

• To ensure electromagnetic compatibility, make sure all connections are tight and the covers are screwed on securely.

• No liability is accepted for damage caused by faulty connections or inappropriate handling of the device.

Check the head-end station

a ccording to the safety instructions listed in their assembly instruction.

Take precautions to prevent static discharge when working on the device!

Electronic devices should never be disposed of in the household rubbish. In accordance with directive 2002/96/EC of the European Parliament and the

European Council from January 27, 2003 which addresses old electronic and electrical devices, such devices must be disposed of at a designated collection facility. At the end of its service life, please take your device to one of these public collection facilities for proper disposal.

2 g eneral information

2.1 s

Cope of delivery

1 SAT IF input distributor SID 162

8 SAT cables

1 Brief Assembly Instructions

Mounting material

- 3 - SID 162

2.2 m eaning of the symbols used

Important note

Performing works

2.3 t eChniCal data

The requirements of the following are met:

2011/65/EU, 2014/30/EU, 2014/35/EU

The product fulfils the guidelines and standards for CE labelling (page 10).

Unless otherwise noted all values are specified as “typical”.

Frequency range: ....................................................... 950 … 2150 MHz

SAT IF inputs: ......................................................................... 2 F sockets

SAT IF loop-through output: ....................................................... 1 F socket

SAT IF outputs: .................................................................. 6 + 4 F sockets

Input / output impedance: .............................................................. 75 Ω

Decoupling of the outputs: ..............................................................20 dB

Loss 1-6 fold (see page 5): .......................................................9 … 14 dB

Loop-through loss: ............................................................................8 dB

Loss 1-4 fold (see page 5) ........................................................9 … 12 dB

LNB operating voltage supply (via external connector): ....... max. 800 mA

2.4 d esCription

The SAT IF distributor SID 162 is equipped with two SAT IF inputs, one loopthrough output and 10 SAT IF outputs. This enables to distribute two reception areas to 4 and 6 SAT IF outputs. Using the loop-through output the reception area 1 can be distributed to the 10 outputs. The F sockets of both reception areas are marked with different colours.

- 4 - SID 162

If the loop-through output is not used it must be terminated using the terminator supplied. The DC power feed (max. 800 mA ) is used for the power supply of the LNBs connected.

The SAT IF distributor SID 162 is designed exclusively for use in the head-end station.

3 o ver view

A D

B

9-12 dB

C

8 dB

9-14 dB

E F

A

LNB power connection

B

Input 2

C

Loop-through output of input 1 with terminator

D

Input 1

E

Outputs of input 1

F

Outputs of input 2

- 5 - SID 162

4 i nstalling the

sat if input distributor

Before installing or changing a module or accessory, switch off the headend station or unplug the power cable from the mains power socket.

Installing the SAT IF input distributor take care that no cables are squeezed off or injured.

• Remove the front cover and the base plate of the head-end station.

• Insert the SAT IF input distributor the LNB power connection

1 above the output collector 2 so that

A

is facing the control panel.

2 1 A

• Fasten the outer sockets of the SAT IF input distributor

3

with two nuts and lock washers put under each.

3

3

Tighten the nuts until the teeth on the lock washers have penetrated the exterior coating and a good connection is made between the housing and the SAT

IF input distributor.

- 6 - SID 162

5 C onneCting the

sat if input distributor

5.1 C onneCting the

hf

ConneCtions

• Connect the outputs modules.

E and F

(page 5) to the appropriate inputs of the

u sing one reCeption area

( loop

through mode

)

• Connect input

F terminals 4

D

of the SAT IF input distributor to one of the pre-installed

in the rear wall of the head-end station using a HF cable made on-site (length approx. 30 cm).

• Connect the loop-through output site (length approx. 30 cm).

C to input B using a HF cable made on-

B

C

D

4

u sing t wo reCeption areas

• Connect inputs B and pre-installed F terminals

D of the SAT IF input distributor to the appropriate

4

in the rear wall of the head-end station using HF cables made on-site (length approx. 30 cm).

• Terminate the loop-through output

C

with the terminator supplied.

B

C

D

4

- 7 - SID 162

5.2 C onneCting the power supply

• Connect plug 6 of the cable of the LNB power connection the contacts “LNB power supply” (800 mA total).

A to one of

A

LNB power supply

6

- 8 - SID 162

6 f inal proCedures

After installing the head-end station, retrofitting accessories or installing modules it is necessary to tighten all cable connections, F terminals and cover screws in order to maintain compliance with current EMC regulations and to ensure a reliable operation.

Securely tighten the cable connections (F connector) using an open-ended

spanner (spanner gap 11 mm).

• Programme the modules connected and the head-end station if necessary.

• Position the breakthroughs in the base plate above the fastening screws 2 .

• Push the base plate in direction of the arrow and lock it with the locking screw 1 .

• Tighten the fastening screws

2

.

2 2

2

1

• Tighten the nuts of retrofitted F terminals if applicable.

• Mount the front cover (see the assembly instructions of the head-end station).

- 9 - SID 162

CE - Declaration of Conformity

GSS Grundig SAT Systems GmbH • Beuthener Straße 43 • D-90471 Nuremberg

Phone: +49 (0) 911 / 703 8877 • Fax: +49 (0) 911 / 703 9210 www.gss.de/en • [email protected]

Service: Phone: +49 (0) 911/703 2221; Fax: +49 (0) 911/703 2326; [email protected]

Alterations reserved. Technical data E. & O.E. © by GSS GmbH 06042016

advertisement

Related manuals

Download PDF

advertisement