Human Machine Interface Systems

Human Machine Interface Systems
© Siemens AG 2008
Human Machine Interface Systems
Catalog ST 80 • 2009
SIMATIC HMI
© Siemens AG 2008
Human Machine Interface
Systems
Catalog ST 80 · 2009
The products and
systems described in this
catalog are manufactured/distributed under
application of a certified
quality management
system in accordance
with DIN EN ISO 9001
(Certified Registration
No. 2613-05).
The certificate is
recognized by all
IQNet countries.
Introduction
1
Operator Control and
Monitoring Devices
2
SIMATIC Panel PC
3
HMI Software
4
HMI complete PC Systems
5
Customized Products
6
Industrial LCD Monitors
7
Fully enclosed HMI Units
8
Appendix
9
Supersedes:
Catalog ST 80 · 2008
The products contained in this
catalog are also contained in
the electronic Catalog CA 01.
Order No.:
E86060-D4001-A500-C7-7600 (DVD)
Please contact
your Siemens branch office.
© Siemens AG 2008
© Siemens AG 2008
ERP – Enterprise Resource Planning
Ethernet
Management Level
MES – Manufacturing Execution Systems
Ethernet
Operations Level
SIMATIC PCS 7
Process Control (DCS)
Industrial Ethernet
Industrial Software for
• Design and Engineering
• Installation and Commissioning
• Operation
• Maintenance
• Modernization
and Upgrade
Control Level
SINUMERIK
Computer Numeric Control
SIMOTION
Motion Control System
Process Instrumentation
SIMATIC Sensors
Field Level
AS-Interface
30.04.2008
PROFIBUS PA
Totally
Integrated
Automation
HART
IO-Link
Setting standards in
productivity and competitiveness.
Totally Integrated Automation.
Thanks to Totally Integrated Automation, Siemens is the only provider
of an integrated basis for implementation of customized automation
solutions – in all industries from inbound to outbound.
1/4
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC IT
SIMATIC WinCC
SCADA System
SIMATIC NET
Industrial
Communication
SIMATIC Controllers
Modular / Embedded /
PC-based
SIMATIC HMI
Human Machine Interface
Safety Integrated
SIRIUS Industrial Controls
SENTRON Switching
Devices
SIMOCODE pro
Motor Management
System
PROFINET
Industrial Ethernet
PROFIBUS
AS-Interface
SINAMICS Drive Systems
SIMATIC Distributed I/O
Totally
Integrated
Power
KNX/EIB GAMMA instabus
TIA is characterized by its unique
continuity.
It provides maximum transparency at
all levels with reduced interfacing
requirements – covering the field level,
production control level, up to the
corporate management level. With TIA
you also profit throughout the complete
life cycle of your plant – starting with
the initial planning steps through
operation up to modernization, where
we offer a high measure of investment
security resulting from continuity in the
further development of our products
and from reducing the number of
interfaces to a minimum.
The unique continuity is already
a defined characteristic at the
development stage of our products
and systems.
The result: maximum interoperability –
covering the controller, HMI, drives, up
to the process control system. This
reduces the complexity of the
automation solution in your plant. You
will experience this, for example, in the
engineering phase of the automation
solution in the form of reduced time
requirements and cost, or during
operation using the continuous
diagnostics facilities of Totally
Integrated Automation for increasing
the availability of your plant.
Siemens ST 80 · 2009
1/5
© Siemens AG 2008
Communication
IEC 61850
PROFINET
BACnet
Industrial Ethernet
PROFIBUS
Processes /
industrial automation
KNX EIB
Products and systems
Medium voltage
Transformers
Low voltage
Installation
technology
Building
automation
≤ 110 kV
03.0 4.2008
Planning and system configuration
Electrical power distribution in
buildings requires integrated solutions.
Our response: Totally Integrated Power.
This means innovative and integrated,
interface-optimized products and
systems which have been optimally
coordinated and complemented with
communication and software modules
that link power distribution to building
automation or industrial automation.
Totally Integrated Power accompanies
power distribution projects from one
end to the other. From A to Z.
From the planning to the building’s use:
Totally Integrated Power offers significant advantages in every project
stage and to everyone involved in the
project – the investors, electrical planning engineers, electricians, users
and building facility managers.
Our portfolio comprises everything
from engineering tools to the matching
hardware: from switchgear and
distribution systems for medium voltage to transformers, from switching
and circuit-protection devices to
low-voltage switchgear and busbar
trunking systems, as far as to the small
distribution board and the wall outlet.
It goes without saying that both the
medium-voltage switchgear, which
requires no maintenance, and the
low-voltage switchgear are type-tested,
and their busbar connections, too.
Comprehensive protection systems
ensure the safety of man and machine
at any time.
Siemens ST 80 · 2009
1/7
© Siemens AG 2008
Gain transparency and lower costs:
SIMATIC HMI operator control and monitoring
systems
The interface between human and machine – the human
machine interface or HMI for short – connects the world of
automation with the individual requirements of the operator.
Operator control and monitoring is about managing the process,
about optimizing machine and system operation, about availability and productivity.
Everything from a single source
With SIMATIC HMI, Siemens A&D offers a complete spectrum of
innovative and low-cost products and systems for the multifaceted tasks of operator control and monitoring: Ranging from
operator panels and visualization software for operator control
and monitoring at the machine through to SCADA systems for
widely differing requirements in process visualization.
For special requirements, optimally adapted products are
offered such as especially rugged operator panels with all-round
IP65 protection for mounting on support arms/pedestals, or
operator panels with stainless steel front for use in the food and
beverages industry. Of course, individual, customer-specific
requirements can also be implemented.
Perfectly equipped for integration in the world of
automation
With their open, standardized interfaces in hardware and software, SIMATIC HMI products can be integrated at any time in the
production and automation level as well as in the company management level. Connectability to almost every controller on the
market as well as multiple language capability of the configuration and visualization software - including Asian ideographic languages, of course - facilitate operation worldwide.
Increased production transparency through Plant
Intelligence
Plant Intelligence is based on the rational use of information to
improve processes within the company. It is designed to lower
plant costs, consolidate and improve quality, avoid wastage,
utilize production facilities better and ultimately ensure greater
efficiency and cost effectiveness within the company. WinCC
provides the best requirements for achieving this since WinCC
features an integrated Historian for acquiring important production data. Using intelligent functions and tools, these process
data can be edited into information necessary for making
decisions and can be made available throughout the company
whenever and wherever it is required – for operators as well as
production managers or anyone else within the company. Even
the WinCC basic system provides a wealth of display and evaluation functions, such as the statistics function for the message
and measured value logs. WinCC options for IT & business
integration make additional "smart" tools available for optimizing
production using Plant Intelligence.
1/8
Siemens ST 80 · 2009
Integrated into the World Wide Web
SIMATIC HMI makes the Internet into a control desk - within a
plant as well as in the worldwide network. Using the WinCC/Web
Navigator, you can monitor and operate plants over the Internet
or over the internal corporate intranet. THIN CLIENT solutions
can be used to integrate rugged, local devices which simultaneously establish the connection between the automation level and
the control center. And over a wireless LAN or cell phone connection, you can use mobile THIN CLIENTS such as laptop computers, PDAs (personal digital assistants) or WebPads. In this
way, process, service or management information can be made
individually available to users. At the machine level, many
control units support remote operation, e.g. as a link between
the automation level and the control room through to service and
diagnostics over the Internet.
With WinCC flexible, concepts with so-called [email protected] and
servers facilitate plant-wide access to variables and graphics,
distributed operator stations as well as remote operation and
diagnostics via the Internet – also in conjunction with SIMATIC
Panels.
Traceability and simple validation
WinCC flexible and WinCC with "FDA options" provide a high
degree of support to machine and plant manufacturers who
must fulfill high quality requirements, both with respect to the
products to be manufactured as well as to the manufacturing
processes themselves. These options simplify plant validation
enormously and thus provide the most convincing and comprehensive solution for the requirements of these sectors.
They support the user in fulfilling high quality requirements as
specified by the FDA (Food and Drug Administration) 21 CFR
Part 11 for the food, beverages and pharmaceutical industries.
© Siemens AG 2008
Increased plant availability
All the advantages of Totally Integrated Automation
All operator panels and Panel PCs are designed for harsh
industrial use. Redundant WinCC process visualization systems
ensure a high degree of plant availability during normal
operation. The ProAgent process diagnostics of SIMATIC HMI
supports you effectively with error locating and elimination and
significantly reduces downtimes.
With Totally Integrated Automation (TIA), Siemens is the only
supplier who offers a system-wide, integrated product and system range for automating the complete production workflow.
The distinguishing feature of TIA is that it is completely integrated. The reduced number of interfaces results in very clear structures. This reduces time and costs required for engineering the
automation solution and increases the availability of the plant.
Distributed operator control concepts
SIMATIC HMI offers different solutions for different requirements
for operator control of large machines and plants spread over
extensive areas.
Thus, the [email protected] option of the SIMATIC WinCC flexible
visualization software, for example, allows devices such as panels, THIN CLIENTS and PCs plant-wide access via PROFINET/
Ethernet to current process values and the local screen images
of all involved stations.
The [email protected] option is used for diagnostics, maintenance
and remote control of local operator stations over the Internet.
As remote operator stations, SIMATIC THIN CLIENTS make the
functionality of machine-level panels available in the control
room or in the office, thanks to their connection to PROFINET/
Ethernet, and in the other direction, they bring SIMATIC WinCC
or office or IT functionality straight to the machine.
In PC-based applications, the computing unit and the operating
unit of a Panel PC 677B can be separated from each other by up
to 30 m. When using PCs such as the SIMATIC Rack or Box PC,
a SIMATIC Flat Panel monitor can also assume the function of the
operating unit at a distance of up to 30 m.
More than just operator control and monitoring
The Multi Panels under Windows CE combine the advantages of
two worlds: On the one hand, the ruggedness of an operator
panel and on the other hand the flexibility typical of a PC.
Apart from classical operator control and monitoring, other automation functions such as control functions can execute simultaneously. And for PC-based automation, the SIMATIC Panel PCs
are available as a compact automation platform - the embedded
versions being especially compact and rugged as well as
maintenance-free.
SIMATIC WinCC flexible, the system-wide engineering tool for
the SIMATIC HMI operator panels, is part of TIA and uses the
same database as STEP 7, the programming software for the
SIMATIC Controllers. This saves input overhead and ensures
data consistency at all times.
In conjunction with other SIMATIC components, SIMATIC HMI
also supports system diagnostics and process diagnostics
during normal operation. You can start STEP 7 diagnostics
directly from WinCC for comprehensive error diagnostics from
the circuit diagram through to the PLC program. The SIMATIC
Maintenance Station visualizes the maintenance information for
the automation technology of a system – from the controller and
network components to switchgear, protective equipment and
control devices and the drives. This gives a clear overview of the
status of the automation at any time.
A competent partner for automation solutions
With SIMATIC HMI, you not only get excellent products to suit
your requirements, we will also support you with selecting a partner for your automation solution. In our worldwide network of
Siemens Automation Solution Partners, you will find competent
contact partners in your area who are always up-to-date with
SIMATIC HMI technology.
The Siemens-internal WinCC Competence Centers implement
technology-specific products as well as customer and sectorspecific solutions on the basis of WinCC. WinCC specialists are
external system integrators who combine their WinCC expertise
with their sector and technology know-how to create tailor-made,
cost-effective solutions. Numerous products from our partners
that perfectly interact with WinCC are available as WinCC Addons.
Investment protection is included
Our many years of experience in the automation engineering
sector are to your advantage. The same applies to our global
service network with its expert support. Further services, such
as a software update service, training, ordering over the Internet,
etc. round off what we have to offer.
SIMATIC HMI
The Human Machine Interface
Siemens ST 80 · 2009
1/9
© Siemens AG 2008
SIMATIC HMI
A whole world of operator control and
monitoring
Process visualization
SIMATIC WinCC
The SCADA system for scalable process visualization to suit any
requirement – from the single-user through to the redundant
multi-user systems, as well as for plant operation and monitoring
over the Internet. WinCC is also the ideal information hub for IT
and business integration, with Plant Intelligence ensuring more
transparency in the production process.
3URFHVV
YLVXDOL]DWLRQ
Single-user PC
Operator control and monitoring directly at the machine
Operator panels
SIMATIC Push Button Panels
Input fields connected to the bus for easy, direct machine
operation.
SIMATIC Micro Panels
Operator panels for small machines and specially designed for
SIMATIC S7-200.
2SHUDWRUFRQWURO
DQGPRQLWRULQJ
GLUHFWO\DWWKH
PDFKLQH
Push Button Panels
Micro Panels
SIMATIC Mobile Panels
Mobile operator panels with or without cables for direct operator
control of the plant and machine from any location.
SIMATIC Basic Panels
Operator panels with basic functionality for small machines and
plants
SIMATIC Panels
Compact and rugged operator panels for use directly at the
machine – finely graded in performance and convenience and
available as Operator Panels and Touch Panels.
SIMOTION
Motion Control
SIMATIC Multi Panels
Multifunctional platforms that, in addition to visualization, also
perform other automation tasks such as controlling.
SIMATIC WinAC MP
The software PLC can be used on the Multi Panels of the 170/270
and 370 series and is suitable for complex processes in which
control and visualization tasks are to be solved with one and the
same device.
Actuators / Sensors
SIMATIC THIN CLIENT
Low-cost, rugged operator stations providing panel functionality
directly on-site for systems covering a relatively large area.
These are used in Client-Server applications.
SIMATIC Panel PC
Industrial platforms for PC visualization locally or for the many
and varied automation tasks of PC-based automation. The new
embedded version is especially compact and rugged as well as
maintenance-free.
SIMATIC Flat Panel monitors
Industry-standard LCD monitors with high-contrast TFT
displays.
SIMATIC Fully Enclosed HMI devices
The SIMATIC Fully Enclosed HMI devices (MP 377 PRO,
THIN CLIENT PRO and Flat Panel PRO) have been specially
designed for mounting on support arms/pedestals.
Thanks to their extremely rugged design, the devices are ideal
for industrial applications in harsh environments.
1/10
Siemens ST 80 · 2009
Mobile
Panels
© Siemens AG 2008
(QWHUSULVH5HVRXUFH3ODQQLQJ(53
0DQXIDFWXULQJ([HFXWLRQ6\VWHPV0(6
3ODQW,QWHOOLJHQFH
Client/Server
Internet Client
Basic Panels
Panels
Multi Panels
SIMATIC controllers
SCADA system WinCC
Thin Clients
S7-400
Panel PCs
HMI software
Flat Panel monitors
WinCC flexible
Additional automation
systems
S7-300
S7-200
Drives
G_ST80_XX_00365
Field devices
Devices with stainless steel fronts
Panels and Panel PCs with touch screens and stainless steel
fronts have been designed for use in the food, beverages and
tobacco industry for operator control and monitoring close to
food processing machines.
SIMATIC WinCC flexible
The innovative HMI software under Windows for all applications at the machine level and on the plant floor. The engineering software facilitates system-wide configuring of all
SIMATIC HMI operator panels - from Micro Panels to on-site
solutions with SIMATIC Panel PCs and local control rooms
with standard PCs. WinCC flexible stands for the highest
degree of configuration efficiency and features additional
options for operation, service and diagnostics via the Web.
Siemens ST 80 · 2009
1/11
© Siemens AG 2008
Operator Control and
Monitoring Devices
2/2
Introduction
2/144
2/8
2/8
2/11
Push Button Panels
SIMATIC PP7
SIMATIC PP17
2/14
2/14
2/16
2/19
2/22
2/25
2/29
Micro Panels
Text Display TD 100C
Text Display TD 200
Text Display TD 200C
Text Display TD 400C
SIMATIC OP 73micro
SIMATIC TP 177micro
2/144
2/146
2/149
2/151
2/152
2/33
2/33
Mobile Panels
Introduction
2/37
2/37
Mobile Panels – 170 series
SIMATIC Mobile Panel 177
2/47
2/47
2/54
Mobile Panels – 270 series
SIMATIC Mobile Panel 277
SIMATIC Mobile Panel 277(F)
IWLAN
2/64
2/64
Basic Panels
KTP400 Basic mono
KTP600 Basic mono
KTP600 Basic color
KTP1000 Basic color
TP1500 Basic color
2/72
2/72
2/76
2/80
Panels – 70 series
SIMATIC OP 73
SIMATIC OP 77A
SIMATIC OP 77B
2/85
2/85
2/89
2/96
Panels – 170 series
SIMATIC TP 177A
SIMATIC TP 177B (incl. INOX)
SIMATIC OP 177B
2/101
2/101
2/106
Panels – 270 series
SIMATIC TP 277 6"
SIMATIC OP 277 6"
2/111
2/111
Multi Panels – 170 series
SIMATIC MP 177
2/116
2/116
Multi Panels – 270 series
SIMATIC MP 277 (incl. INOX)
2/126
2/126
Multi Panels – 370 series
SIMATIC MP 377
2/135
2/135
Multi Panel options
SIMATIC WinAC MP
2/140
SIMATIC THIN CLIENT
2/158
2/159
2/164
2/165
2/166
2/168
2/169
2/170
2/171
2/172
2/174
2/175
2/176
2/177
2/178
System interfaces: Panels and
runtime software
Introduction
SIMATIC S7
SIMATIC S5
SIMATIC 505
PLCs from other manufacturers
HMI Accessories
Connecting cables
Bus connector RS485
IE FC RJ45 Plug 2 x 2
Accessories for SIMATIC Mobile
Panels – connection boxes
Accessories for SIMATIC Mobile
Panels – charging station
Accessories for SIMATIC Mobile
Panels – Transponder
Memory cards
Converters/adapters
Service packs
Protective covers
Cover foils
Clamping frame
Back-up battery and accumulator
Recommended printers for Panels
and Multi panels
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Introduction
■ Overview
2
■ Benefits
A finely graded range of HMI devices is available for local
operator control and monitoring. These include Push Button
Panels and Micro Panels up to Mobile Panels, Basic Panels,
Panels and Multi Panels. HMI devices with all round IP65/NEMA
4 protection for distributed configurations are available for
applications with especially high requirements with regard to
ruggedness.
Push Button Panels
Push Button Panels (PP) are the innovative alternative to conventionally wired operator keypads. Supplied pre-assembled and
ready for installation, the bus-compatible operator panels are
the key to drastically reducing wiring times when compared with
conventional methods.
Rugged and compact for use at machine level.
With degree of protection IP65/NEMA 4 on the front side, high
EMC and extreme vibration resistance, the SIMATIC Operator
Panels are ideally suited for the use at machine level in rough industrial environments. Thanks to their compact design with a
shallow mounting depth, the stationary Operator Panels can be
fitted anywhere, even where only restricted space is available.
For distributed configurations, there are also devices available
with all-round degree of protection IP65/NEMA 4.
The extremely rugged and shock-proof housing with degree of
protection IP65 makes the Mobile Panels especially suitable for
industrial applications. Their low weight and ergonomic design
means that they are user-friendly and easy to operate.
Micro Panels
One configuration software for everything
Designed specifically for applications with the SIMATIC S7-200
micro PLC, either with text display (TD) or pixel-graphics
display, as operator panels (OP) with membrane keyboard or
touch screen (TP).
SIMATIC WinCC flexible is a tool for continued configuration of
all SIMATIC Panels as well as PC-based systems with the visualization software WinCC flexible Runtime. Graded variants are
available for every task. The software permits simple and efficient configuration. Programming experience is not required.
Mobile Panels
The portable operator panels facilitate operator control and
monitoring at the actual scene of the event with direct access
and visual contact to the process. They provide simple and safe
reconnection during operation (Mobile Panel 177 and Mobile
Panel 277) or wireless freedom (Mobile Panel 277 (F) IWLAN)
and can therefore be used flexibly on a machine or system.
Basic Panels
Basic Panels offer basic HMI functionality for small machines
and applications. They are available in four different display
sizes from 4" to 15", with touch displays and additional keys, for
connecting to PROFINET/Ethernet or PROFIBUS DP/MPI.
Panels
Graphic Panels of 70/170/270 series
with pixel-graphics display in 4" or 6" for realistic presentation
of operating sequences. Either as Touch Panels (TP) with touchsensitive display, Operator Panels (OP) with membrane
keyboard, or touch/key combination on the OP 177B 6" or
TP 177B 4".
Multi Panels
170/270/370 series
Like Panels, they can be used for operator control and monitoring and are available with touchscreens or membrane keyboards. In addition, the Multi Panels (MPs) permit installation of
additional applications and thus allow integration of several automation tasks on a single platform with the PLC WinAC MP software, for example. The 370 series also encompasses a device
with all-round IP65/NEMA 4 protection and 15" touch display for
distributed configurations.
WinAC MP
The software PLC can be used in the 170/270 and 370 Multi
Panels (exception: MP 370) and is ideal for complex processes
in which one device must handle control and visualization tasks.
THIN CLIENT
SIMATIC THIN CLIENTS are inexpensive, rugged operator
stations providing panel functionality directly on-site for systems
covering a relatively large area. These are used in Client-Server
applications. As well as built-in units, the series also includes a
15" touch display device with all-round IP65/NEMA 4 protection
for distributed configurations.
2/2
Siemens ST 80 · 2009
Completed configurations can be reused within the family.
Component of Totally Integrated Automation
Siemens provides the complete modular system of matched
components for automation solutions from one source and –
with Totally Integrated Automation – one of the most successful
automation concepts worldwide. SIMATIC WinCC flexible is an
integral component of this world. It offers crucial advantages.
Thanks to the uniformity in configuration/programming, data
management and communication, the engineering costs of an
automation solution are significantly reduced.
Open for a wide variety of automation systems
Despite the consistent incorporation into the SIMATIC world, the
Panels are nevertheless open for connection to PLCs from many
different vendors. The standard delivery includes a comprehensive range of user-friendly drivers.
Innovative operator control and monitoring
Based on the Windows CE operating system, 70, 170, 270 and
370 Series Mobile Panels, Panels and Multi Panels permit innovative operator control and monitoring combined with ruggedness, stability and simplicity. Standard hardware and software
interfaces provide more flexibility and openness to the office
world, for example, the MMC/SD/CF card, USB, Ethernet,
PROFIBUS DP, Visual Basic scripts or customer-specific
ActiveX controls.
Worldwide application
The SIMATIC Panels are ideal for global use by design. Online
language selection permits selection of up to five languages
during operation simply by pressing a button. The wide variety
of languages available also includes, for example, Asian logographic languages (Chinese, Taiwanese, Korean, Japanese) or
Russian. The configuration interface of WinCC flexible including
the online help and the complete documentation is also multilingual. Up to 32 languages can be used in one project. And all this
is complemented by global servicing and support from Siemens.
© Siemens AG 2008
Operator Control and Monitoring Devices
Introduction
■ Configuration overview
WinCC flexible engineering software
Micro
Compact
Standard
Advanced
OP 73micro
I
I
I
I
TP 177micro
I
I
I
I
KTP400 Basic
I4)
I4)
I4)
KTP600 Basic
I4)
I4)
I4)
KTP1000 Basic
I4)
I4)
I4)
4)
4)
I
I4)
Micro Panels
2
Basic Panels
TP1500 Basic
I
Mobile Panels
Mobile Panel 177
I1)
I1)
I1)
Mobile Panel 277
I2)
I2)
I2)
3)
I
I3)
Mobile Panel 277 (F) IWLAN
Panels – 70 series
OP 73
I
I
I
OP 77A/B
I
I
I
TP 177A
I
I
I
TP/OP 177B
I1)
I1)
I1)
I2)
I2)
I4)
I4)
I
I
I3)
I3)
Panels – 170 series
Panels – 270 series
TP 277/OP 277 6"
170 series Multi Panels
MP 1775)
Multi Panels – 270 series
MP 277
Multi Panels – 370 series
MP 377
I
Possible
1)
WinCC flexible 2005 or higher and TP 177B 4" with WinCC flexible 2008
and higher
2)
WinCC flexible 2005 SP1 and higher
3)
WinCC flexible 2007 and higher
4)
WinCC flexible 2008 and higher
Siemens ST 80 · 2009
2/3
© Siemens AG 2008
Operator Control and Monitoring Devices
Introduction
■ Technology overview
Micro Panels
Mobile Panels
Basic Panels
70 series
170 series
270 series
TD 100C1)/
TD 200/ TD 200C1)
TD 400C1)
OP 73micro
TP 177micro
Mobile Panel 177/
Mobile Panel 277/
Mobile Panel 277(F)
IWLAN
KTP400 Basic
KTP600 Basic
KTP1000 Basic
TP1500 Basic
OP 73
OP 77A/B
TP 177A
TP/OP 177B
TP/OP 277
Display
TD 100C
TD 200/ TD 200C
TD 400C:
Text display
OP 73micro:
3" LCD
TP 177micro:
5.7" STN
Mobile Panel 177:
5.7" STN;
Mobile Panel 277 /
277 (F) IWLAN:
7.5" TFT
KTP400 Basic
3.8" STN
KTP600 Basic
5.7" STN or 5.7" TFT
KTP1000 Basic
10.4" TFT
TP1500 Basic
15.1" TFT
OP 73:
3" LCD
OP 77A/B:
4.5" LCD
TP 177B 4":
5.7" TFT
4.3" TFT widescreen
otherwise:
5.7" STN
Colors
TD 100C
TD 200/ TD 200C/
TD 400C/
OP 73micro:
Monochrome
TP 177micro:
4 shades of blue
Mobile Panel 177:
256 colors;
Mobile Panel 277 /
277 (F) IWLAN:
64k colors
KTP400 Basic
4 shades of gray
KTP600 Basic
4 shades of gray
or 256 colors
KTP1000 Basic
256 colors
TP1500 Basic
256 colors
Monochrome
TP 177A:
4 shades of blue
TP/OP 177B:
4 shades of
blue/256 colors
256 colors
Membrane
keyboard
I
–
I
I
I
I
Touch screen
I
2
Panels
Operator controls
(TD 200/TD 200C/
TD 400C/
OP 73micro)
(KTP400/KTP600/
KTP1000)
–
I
–
I
I
I
I
–
I
–
(TP 177micro)
Membrane
keyboard and
Touch
–
(KTP400/KTP600/
KTP1000)
(only on OP 177B 6"
and TP 177B 4")
Interfaces/
protocols
Serial / MPI /
PROFIBUS DP
I/I/–
I9) / I9) / I9)
I13) / I13) / I13)
I/I/I
I/I/I
I/I/I
USB/Ethernet /
WLAN
–/–
I10) / I5) / I11)
– / I14) / –
I3) / –
I / I7)
I/I
Multimedia card /
CF / PC card slot
–/–/–
I/–/–
– /– /–
I 3) / – / –
I / I4) / –
I/–/–
Memory
(available for
user data)
TD 100C
TD 200/ TD 200C/
TD 400C/
OP 73micro:
128 KByte
TP 177micro:
256 KB
Mobile Panel 177:
2048 KB;
Mobile Panel 277 /
277(F) IWLAN:
6 MB
KTP400 Basic/
KTP600 Basic:
512 KB
KTP1000 Basic/
TP1500 Basic:
1024 KB
OP 73/OP 77A:
256 KB
OP 77B
1024 KB
TP 177A
512 KB
TP/OP 177B:
2 MB
4 MB
2/4
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Introduction
■ Technology overview (continued)
Micro Panels
Mobile Panels
Basic Panels
Panels
70 series
170 series
270 series
TD 100C1)/
TD 200/ TD 200C1)
TD 400C1)
OP 73micro
TP 177micro
Mobile Panel 177/
Mobile Panel 277/
Mobile Panel 277(F)
IWLAN
KTP400 Basic
KTP600 Basic
KTP1000 Basic
TP1500 Basic
OP 73
OP 77A/B
TP 177A
TP/OP 177B
TP/OP 277
SIMATIC S7 /
WinAC
S7-200 only
I / I12)
I/I
I/I
I/I
I/I
SIMATIC S5 / 505
–/–
I12) / I12)
–/–
I6) / I6)
I4) / I4)
I/I
–/–
–/–
I / I4)
I/I
2
Connection to
controller
12)
12)
SINUMERIK /
SIMOTION
–/–
I
/I
PLCs from other
manufacturers
–
I12)
I13)
I6)
I4)
I
–
–
–
–
–
I
[email protected]
–
I5)
–
–
I7)
I
[email protected]
–
I5)
–
–
I7)
I
OPC server
–
–
–
–
–
–
ThinClient/MP
–
–
–
–
–
–
I10)
–
–
–
–
–
–
–
–
–
Applications/
Options with
WinCC flexible
ProAgent
MS Pocket Internet –
Explorer
WinAC MP
–
I Available
– Not available
1)
The configuration of the TD 100C/TD 200/TD 200C/TD 400C is done with
Micro/WIN
2)
Except OP3
3)
Only with OP 77B
4)
Not with TP 177A, TP/OP 177B (S5 only)
5)
Not with Mobile Panel 177 DP
6)
With OP 73 and OP 77A, connection only possible to S7-200/300/400
7)
Only with TP/OP 177B color
8)
Only with TP/OP 177B
9)
Only with Mobile Panel 177 DP/Mobile Panel 277
10)
Only Mobile Panel 277/277(F) IWLAN
11)
Only Mobile Panel 277(F) IWLAN
12)
Only with Mobile Panel 277(F) IWLAN
13)
Only with KTP600 Basic DP and KTP1000 Basic DP
14)
Not with KTP600 Basic DP and KTP1000 Basic DP
Siemens ST 80 · 2009
2/5
© Siemens AG 2008
Operator Control and Monitoring Devices
Introduction
■ Technology overview (continued)
Multi Panels
2
170 series
270 series
370 series
MP 177
MP 277
MP 377
Display
6" TFT
7.5"/10.4" TFT
12"/15/19" TFT
Colors
65535 colors
65535 colors
65535 colors
• Membrane keyboard
–
I
I
• Touch screen
I
I
I
• Membrane keyboard and
Touch
–
–
–
Serial / MPI / PROFIBUS DP
–/I/I
–/I/I
–/I/I
USB / Ethernet
I/I
I/I
I/I
Multi Media Card or SD Card /
CF / PC Card Slot
I/–/–
I/–/–
I/I/–
Memory
(available for user data)
2 MB
5 MB
12 MB
SIMATIC S7 / WinAC
I/I
I/I
I/I
SIMATIC S5 / 505
I/I
I/I
I/I
SINUMERIK / SIMOTION
I/I
I/I
I/I
PLCs from other manufacturers
I
I
I
ProAgent
I
I
I
[email protected]
I
I
I
[email protected]
I
I
I
OPC server
–
I
I
MS Pocket Internet Explorer
–
I
I
10" Touch
15" Touch
PRO 15" Touch
Operator controls
Interfaces/protocols
Connection to controller
Applications/Options with
WinCC flexible
I Available
– Not available
THIN CLIENT
Display
Type
TFT, 65 536 colors
TFT, 65 536 colors
TFT, 65 536 colors
Size
10.4"
15.1"
15.1"
Resolution
640 x 480
1024 x 768
1024 x 768
MTBF backlighting (at 25 °C)
approx. 50 000 h
approx. 50 000 h
approx. 50 000 h
I
I
I
I
I
I
[email protected]
I
I
I
RDP
I
I
I
LLDP
I
I
I
HTTP
I
I
I
XML
I
I
I
HTML
I
I
I
CSS
I
I
I
Operator controls
Touch screen
Interfaces
USB / Ethernet
Protocols (terminal connection)
Web characteristics
2/6
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Introduction
■ Functionality (when configuring with WinCC flexible)
Micro Panels Mobile Panels Basic Panels
Panels
70 series
Multi Panels
170 series
270 series 370 series
OP 73micro/
TP 177micro
Mobile
Panel 177/Mo
bile Panel
277/277 (F)
IWLAN
KTP400 Basic OP 73/
KTP600 Basic OP 77A/
KTP1000 Basic OP 77B
TP1500 Basic
TP 177A
TP/OP 177B
TP 277/
OP 277
MP 177
MP 277
MP 377
Number
of messages
OP 73micro:
250
TP 177micro:
500
Mobile
Panel 177:
2000
Mobile Panel
277/277 (F)
IWLAN:
4000
200
OP 73:
500
OP 77A/
OP 77B:
1000
TP 177A:
1000
TP/OP 177B:
2000
4000
4000
4000
4000
Message buffer
(number of
entries)
1283)
OP 73micro:
100
Mobile
Panel 177:
256
Mobile Panel
277/277 (F)
IWLAN:
512
256
OP 73:
150
OP 77A/B:
256 3)
TP 177A3)/
TP/OP 177B:
256
512
512
512
1024
Recipes
–
Mobile
Panel 177
100
Mobile Panel
277/277 (F)
IWLAN:
300
5
OP 77A:
5
OP 77B:
100
TP 177A:
57)
TP/OP 177B:
100
300
300
300
500
Process images
250
500
50
500
TP 177A:
250
TP/OP 177B:
500
500
500
500
500
Bar graphs/
line graphs
(pixel graphics)
I / I6)
I/I
I/I
I/–
I / I7)
I/I
I/I
I/I
I/I
Variables
OP 73micro:
500
TP 177micro:
250
Mobile
Panel 177:
1024
Mobile Panel
277/277 (F)
IWLAN:
2048
KTP400/600
Basic:
128
KTP1000
Basic/TP1500
Basic:
256
1000
TP 177A:
500
TP/OP 177B:
1000
2048
2048
2048
40968)
Archiving
–
I5)
–
–
–
I
I
I
I
Visual Basic
scripts
–
I5)
–
–
–
I
I
I
I
Online
languages
5
5
5
5
TP 177A:
5
TP/OP 177B:
16
5
16
16
16
User administration (security)
I
I
I
I
I
I
I
I
I
Print functions
–
I
–
I2)
I1)
I
I
I
I
–
I5)
–
–
I4)
I
I
I
I
PG functions
(STATUS/
CONTROL) with
SIMATIC S5/S7
170 series
270 series
I Available
– Not available
1)
Except TP 177A
2)
Only with OP 77B
3)
Non-retentive
4)
Only with TP/OP 177B
5)
Only Mobile Panel 277/277(F) IWLAN
6)
Only for TP 177micro
7)
On TP 177A from WinCC flexible 2007
8)
WinCC flexible 2008 and higher
Siemens ST 80 · 2009
2/7
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Push Button Panels
SIMATIC PP7
■ Overview
■ Application
The rugged PP7 Push Button Panel is designed for simple and
straightforward machine operation.
It can be used wherever HMI functions cannot be carried out
without keys and lamps, e.g. on control consoles for machines
and plants in the food and beverage industry where smooth
fronts are necessary to facilitate cleaning. Even in special
mechanical equipment manufacture, the push button panels
can be used to easily set up standard operator panels that are
then amenable to fast, flexible and modular expansion. The key
and lamp functions can be changed later at any time without
having to modify the wiring.
2
■ Design
SIMATIC Push Button Panels are the innovative alternative to
conventional operator panels for easy and direct control of
machines:
• Pre-fabricated and ready for operation;
simply connect to the control and all buttons and lamps are
ready for immediate use
• Connection to any type of control via a bus cable
(PROFIBUS DP as "standard slave" or MPI)
• Fitted with short-stroke keys, additional digital inputs and
slots for 22.5 mm standard components
■ Benefits
• Up to 90 % time savings: Pushbuttons, switches and lamps do
not have to be fitted and wired individually
• Use of standard cables, for example, makes configuration and
startup easier
• No configuration tool required
• Service-friendly thanks to rear display to indicate operating
states and messages in plain text, without programming
device
• Quick and easy machine operation thanks to multi-colored
indicator lights
• User-friendly labeling option for pushbuttons and lamps using
slide-in labels
• As the 22.5 mm standard elements can be connected directly
on the panel, no additional wiring and I/O modules are
required.
2/8
Siemens ST 80 · 2009
PPs stand out because of their compact construction:
• Preassembled with 8 short-stroke keys that can be labeled
individually with slide-in labels
• Smooth, easy to clean front;
the front is resistant to various oils, greases and standard
detergents
• Long-life, multi-colored surface LEDs in all short-stroke keys
• Additional digital inputs for flexible expansion
• Pre-perforated cut-outs for 22.5 mm standard auxiliary
elements (buttons, lamps, Emergency Stop, key switch)
• Rear-side display with miniature keyboard for displaying
operating status and changing standard settings in text format
• The PP7 fits seamlessly into the series
• Maintenance-friendly, no battery required
• All parameters are stored on a memory module, which can be
easily replaced
■ Function
• LED color modes (e.g., red, green, yellow, red-flashing, greenflashing, yellow-flashing)
• Integrated flashing rate for LED
• Integrated diagnostic functions
• Integrated lamp and key test (also for additional digital inputs)
• Menu-assisted parameterization via rear display with
miniature keyboard
• Short-stroke keys and digital inputs are also parameterizable
as switches
• Parameterizable pulse stretching for short-stroke keys and
digital inputs
• PROFIBUS DP standard slave
© Siemens AG 2008
Operator Control and Monitoring Devices
Push Button Panels
SIMATIC PP7
■ Integration
■ Technical specifications
The Push Button Panels can be connected to
• SIMATIC S7-200/-300/-400, WinAC Software and Slot PLC via
MPI and PROFIBUS DP
• SIMATIC S5 (AG95/master or IM 308C) only via PROFIBUS DP
• PROFIBUS DP standard master, any vendor (e.g. Allen
Bradley, etc.)
System interfaces
Controller
SIMATIC PP7 1)
Target hardware (PROTOCOL)
(connector/physics)
Connection via DP/MPI
SIMATIC S7/SIMATIC WinAC (MPI as master)
via MPI interface with
S7-200/-300/-400/
WinAC Software/Slot PLC
(9-pin socket/RS 485),3)4)
Bus connector,
bus cable and MPI network
(see Catalog ST 70/IK PI)
via PROFIBUS with max. 1 x
S7-200 (CPU 215-DP)
on MPI protocol
S7-300/-400
with integrated PROFIBUS interface
S7-300 with CP 342-5
S7-400 with CP 443-5
PROFIBUS 5)
(see Catalog ST 70/IK PI)
via PROFIBUS DP with
S5-95U/PROFIBUS DP master
(6ES5 095-8ME02)
S5-115U/-135U/-155U
with IM 308C/IM 308B
S5-115U/-135U/-155U
with CP 5430/CP 5431
PROFIBUS 5)
(see Catalog ST 70/IK PI)
24 V DC
Permissible range
+18 V to +30 V DC
Rated current
0.2 A
Power
5W
2
Digital inputs
Voltage (DC)
24 V
Number of digital inputs
4
Operating elements
Membrane keyboard
Function keys, programmable
8 function keys, 8 with LEDs
Membrane keyboard
Yes
Ambient conditions
Mounting position
Vertical
Maximum permissible angle of
incliniation without external
ventilation
+/- 35 °
Max. relative humidity (in %)
95%
Temperature
Operation (vertical installation)
0 °C to +55 °C
Operation (max. tilt angle)
0 °C to +55 °C
Transport, storage
-20 °C to +70 °C
Degree of protection
Non-Siemens controllers (PROFIBUS DP master)
1)
Supply voltage
Operating mode
2)
SIMATIC S5/S7 (PROFIBUS DP as standard slave)
via PROFIBUS DP
SIMATIC PP7
Supply voltage
5)
PROFIBUS
(see Catalog ST 70/IK PI)
Front
IP65
Rear
IP20
Certifications & Standards
Certifications
PP7 suitable up to 1.5 Mbit/s
2)
Standard PG/PC MPI cable cannot be used
3)
CE, FM Class I Div. 2, UL, CSA
Type of output
S7-200 only via MPI (CPU 212 not possible)
LED colors
Red, yellow, green
4)
S7-200 CPU 215-DP also possible on PROFIBUS DP interface via MPI
protocol
Color modes for LED
3
5)
Bus connector: 6GK1 500-0EA02
Number of LEDs
8
Note:
The standard PG/PC MPI cable (6ES7 901-0BF00-0AA0) cannot
be used to connect a PP and a CPU.
Lifetime, typ.
Short-stroke keys (in switching
cycles)
1 500 000
LEDs (ON period)
100 %
Functionality
Short lift keys/additional inputs as
pushbuttons or switches
Yes
Flashing frequency for LEDs
0.5 Hz
Pushbutton and lamp test
Yes
Max. pulse extension for shortstroke keys and digital inputs
1 000 ms
Release input
No
Dimensions
Front of enclosure (W x H) in mm
144 x 204
Mounting cutout/Device depth
(W x H/D) in mm
130 x 190 / 53
Weights
Weight
0.8 kg
Siemens ST 80 · 2009
2/9
© Siemens AG 2008
Operator Control and Monitoring Devices
Push Button Panels
SIMATIC PP7
■ Ordering data
SIMATIC PP7
6AV3 688-3AA03-0AX0
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
Push Button Panel incl. mounting
accessories:
• 8 x short-stroke keys
144
• 8 x surface lighting diodes
128
55
• 4 x DI terminals (24 V)
204
Documentation (to be ordered separately)
204
108
• Max. 5 x 22.5 mm pre-perfor.
cutouts for additional
components
188
Manual for PP7/PP171)
• German
6AV3 991-1CA00-0AA0
• English
6AV3 991-1CA00-0AB0
• French
6AV3 991-1CA00-0AC0
4
• Italian
6AV3 991-1CA00-0AD0
30
• Spanish
6AV3 991-1CA00-0AE0
Brief startup guide
G_ST80_XX_00061
2
Order No.
A
■ More information
for PP7, PP17-I, PP17-II
• German
6AV3 991-1CA00-1BA0
Additional information is available in the Internet under:
• English
6AV3 991-1CA00-1BB0
http://www.siemens.com/panels
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
A) Subject to export regulations: AL: N and ECCN: EAR99H
1)
Incl. 3.5" diskette with GSD files/type files and Word templates for
labeling strips
Note:
Commercially available printing film (0.13 to 0.16 mm strength)
can be used as labeling strips for the keyboard. Word templates
are enclosed with the manual on a diskette.
2/10
Siemens ST 80 · 2009
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
© Siemens AG 2008
Operator Control and Monitoring Devices
Push Button Panels
SIMATIC PP17
■ Overview
■ Application
The rugged PP17 Push Button Panels are designed for easy and
straight-forward operation of the machine.
They can be used wherever keys and lamps are essential components in a human-machine interface. In the food processing
industry, for example, on machines and systems on which
smooth fronts are required for easier cleaning. Even in special
mechanical equipment manufacture, the push button panels
can be used to easily set up standard operator panels that are
then amenable to fast, flexible and modular expansion. The key
and lamp functions can be changed later at any time without
having to modify the wiring.
■ Design
SIMATIC Push Button Panels are the innovative alternative to
conventional operator panels for easy and direct control of
machines:
• Pre-fabricated and ready for operation;
simply connect to the control and all buttons and lamps are
ready for immediate use
• Connection to any type of control via a bus cable
(PROFIBUS DP as "standard slave" or MPI)
• PP17-I:
Fitted with short-stroke keys, additional digital inputs and
outputs and slots for 22.5 mm standard elements
PP17-II:
Fitted with short-stroke keys, additional digital inputs and
outputs and much more
■ Benefits
• Up to 90 % time savings: Pushbuttons, switches and lamps do
not have to be fitted and wired individually
• Use of standard cables, for example, makes configuration and
startup easier
• No configuration tool required
• Service-friendly thanks to rear display to indicate operating
states and messages in plain text, without programming
device
• Quick and easy machine operation thanks to multi-colored
indicator lights
• User-friendly labeling option for pushbuttons and lamps using
slide-in labels
• As the 22.5 mm standard elements can be connected directly
on the panel, no additional wiring and I/O modules are
required
PPs stand out because of their compact construction:
• Preassembled with short-stroke keys that can be labeled
individually – also in color – with slide-in labels
• Smooth, easy to clean front;
the front is resistant to various oils, greases and standard
detergents
• Long-life, multi-colored surface LEDs in all short-stroke keys
• Additional digital inputs and outputs for flexible expansion
• Pre-perforated cut-outs for 22.5 mm standard auxiliary
elements (buttons, lamps, etc.) for PP17-I
• Rear-side display with miniature keyboard for displaying
operating states and changing standard settings in text format
• Central enabling input
• The PP17 can be laterally mounted
• Maintenance-friendly, no battery required
• All parameters are stored on a memory module, which can be
easily replaced
■ Function
• LED color modes (e.g., red, green, yellow, red-flashing, greenflashing, yellow-flashing)
• Integrated flashing frequency for digital outputs and LED
• Integrated diagnostic functions
• Integrated lamp and key test (also for additional digital inputs
24 V inputs and outputs)
• Menu-assisted parameterization via rear display with
miniature keyboard
• Short-stroke keys and digital inputs are also parameterizable
as switches
• Parameterizable pulse stretching for short-stroke keys and
digital inputs (max. 1000 ms)
• PROFIBUS DP standard slave
Siemens ST 80 · 2009
2/11
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Push Button Panels
SIMATIC PP17
■ Integration
2
■ Technical specifications
The Push Button Panels can be connected to:
• SIMATIC S7-200/-300/-400, WinAC Software and Slot PLC via
MPI and PROFIBUS DP
• SIMATIC S5 (AG95/master or IM 308C) only via PROFIBUS DP
• PROFIBUS DP standard master, any vendor (e.g., Allen
Bradley, etc.)
System interfaces
Controller
SIMATIC PP171)
Target hardware (PROTOCOL)
(connector/physics)
Connection via DP/MPI
SIMATIC S7/SIMATIC WinAC (MPI as master)
via MPI interface with
S7-200/-300/-400/
WinAC Software/Slot PLC
(9-pin socket/RS 485),3)4)
2)
Bus connector, connecting
cable and MPI network
(see page 2/144)
SIMATIC S5/S7 (PROFIBUS DP as standard slave)
5)
via PROFIBUS with max. 1 x
S7-200 (CPU 215-DP)
on MPI protocol
S7-300/-400
with integrated PROFIBUS interface
S7-300 with CP 342-5
S7-400 with CP 443-5
PROFIBUS
(see page 2/144)
via PROFIBUS DP with
S5-95U/PROFIBUS DP master
(6ES5 095-8ME02)
S5-115U/-135U/-155U
with IM 308C/IM 308B
S5-115U/-135U/-155U
with CP 5430/CP 5431
PROFIBUS5)
(see page 2/144)
PP17-II
24 V DC
Supply voltage
24 V DC
Permissible range
+18 V to +30 V DC +18 V to +30 V DC
Rated current
0.4 A
0.4 A
Power
10 W
10 W
Voltage (DC)
24 V
24 V
Number of digital inputs
16
16
Digital inputs
Digital outputs
Total power
12 W
12 W
Number of digital outputs
16
16
in groups of
4
4
Aggregate current
(per group) max.
500 mA
500 mA
Short-circuit protection
Yes
Yes
Operating elements
Membrane
keyboard
Membrane
keyboard
Function keys, programmable
16 function keys,
16 with LEDs
32 function keys,
32 with LEDs
Front
IP65
IP65
Rear
IP20
IP20
CE, FM Class I
Div. 2, UL, CSA
CE, FM Class I
Div. 2, UL, CSA
Operating mode
Degree of protection
Certifications & Standards
Non-Siemens controllers (PROFIBUS DP master)
via PROFIBUS DP
PP17-I
Supply voltage
Certifications
PROFIBUS5)
Ambient conditions
1)
PP17 suitable up to 12 Mbit/s
Mounting position
Vertical
Vertical
2)
Standard PG/PC MPI cable cannot be used
3)
+/- 35 °
S7-200 only via MPI (CPU 212 not possible)
4)
S7-200 CPU 215-DP also possible on PROFIBUS DP interface via MPI
protocol
Maximum permissible angle of +/- 35 °
incliniation without external
ventilation
5)
Bus connector: 6GK1 500-0EA02
Note:
The standard PG/PC MPI cable (6ES7 901-0BF00-0AA0) cannot
be used to connect a PP and a CPU.
Max. relative humidity (in %)
95%
95%
Temperature
Operation (vertical installation) 0 °C to +55 °C
0 °C to +55 °C
Operation (max. tilt angle)
0 °C to +55 °C
0 °C to +55 °C
Transport, storage
-20 °C to +70 °C
-20 °C to +70 °C
Type of output
LED colors
Red, yellow, green Red, yellow, green
Color modes for LED
3
3
Number of LEDs
16
32
Short-stroke keys
(in switching cycles)
1 500 000
1 500 000
LEDs (ON period)
100 %
100 %
Lifetime, typ.
Functionality
Short lift keys/additional inputs Yes
as pushbuttons or switches
Flashing frequency for LEDs
0.5 Hz
0.5 Hz
Flashing frequency for digital
outputs
0.5 Hz or 2 Hz
0.5 Hz or 2 Hz
Pushbutton and lamp test
Yes
Yes
max. pulse extension for short- 1 000 ms
stroke keys and digital inputs
Release input
2/12
Siemens ST 80 · 2009
Yes
Yes
1 000 ms
Yes
© Siemens AG 2008
Operator Control and Monitoring Devices
Push Button Panels
SIMATIC PP17
■ Technical specifications (continued)
■ Dimensions
PP17-I
PP17-II
Front of enclosure (W x H)
240 mm x
204 mm
240 mm x
204 mm
Mounting cutout/Device depth
(W x H/D)
226 mm x
190 mm / 53 mm
device depth
226 mm x
190 mm / 53 mm
device depth
1.2 kg
1.5 kg
All specifications in mm. Panel cutout see technical specifications.
Dimensions
224
53
A
204
6AV3 688-3CD13-0AX0
• 16 x short-stroke keys
• 16 x surface lighting diodes
4
• 16 x DI terminals (24 V)
32
• 16 x DO terminals (24 V)
• 1 x enabling input
PP17-I
• Max. 12 x 22.5 mm pre-perfor.
cutouts for additional
components
incl. mounting accessories
PP17-II
G_ST80_XX_00059
PP17-I
Order No.
204
■ Ordering data
188
95
Weights
Weight
2
240
240
A
6AV3 688-3ED13-0AX0
224
53
• 32 x short-stroke keys
• 32 x surface lighting diodes
99
• 16 x DI terminals (24 V)
204
• 1 x enabling input
204
188
• 16 x DO terminals (24 V)
Documentation (to be ordered separately)
Manual for PP7/PP17 1)
6AV3 991-1CA00-0AA0
4
• English
6AV3 991-1CA00-0AB0
32
• French
6AV3 991-1CA00-0AC0
• Italian
6AV3 991-1CA00-0AD0
• Spanish
6AV3 991-1CA00-0AE0
• German
Brief startup guide
G_ST80_XX_00060
incl. mounting accessories
PP17-II
■ More information
for PP7, PP17-I, PP17-II
• German
6AV3 991-1CA00-1BA0
Additional information is available in the Internet under:
• English
6AV3 991-1CA00-1BB0
http://www.siemens.com/panels
see HMI accessories,
from page 2/158
Note:
Accessories
Accessories for supplementary
ordering
A) Subject to export regulations: AL: N and ECCN: EAR99H
1)
Incl. 3.5" diskette with GSD files/type files and Word templates for labeling
strips
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
Note:
Commercially available printing film (0.13 to 0.16 mm strength)
can be used as labeling strips for the keyboard. Word templates
are enclosed with the manual on a diskette.
Siemens ST 80 · 2009
2/13
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 100C
■ Overview
■ Function
2
• The low-cost text display for the S7-200 with customized
display
• For HMI functions:
Display of message texts, interventions in the control program,
setting of inputs and outputs
• Direct connection to CPU interface
• No separate power supply required
• No separate parameterization software required
• Front design can be selected individually
• Addressing and setting of contrast in supplied menu
■ Application
The TD 100C Text Display is the low-cost solution for the simple
HMI tasks of SIMATIC S7-200. The ability to print the surface of
the device individually allows it to be optimally adapted to the
application environment.
It supports:
• Display of message texts
• Interventions in the control program, e.g. modification of
setpoints
• Setting of inputs and outputs, e.g. for switching a motor on
and off
■ Design
The TD 100C is simply connected to the PPI interface of the
S7-200 using the connecting cable that is available as an accessory. A separate power supply is not required. It is also possible
to connect several TDs to one S7-200.
The TD 100C features:
• Rugged plastics housing with IP65 degree of protection
(front):
Increased water tightness thanks to absence of slots for
labeling strips
• Mounting depth of 36 mm (up to 44 mm with fixing):
the TD 100C can be mounted without additional accessories
in control cabinets or operator panels, or used as a handheld
unit.
• Reflecting 4-line display.
• Integrated interface for connection of cable
• Individually designable user interface:
The control elements of the front of the device as well as the
design can be configured individually on a printable sheet.
The Keypad Designer (a component of STEP 7-Micro/WIN)
is used for configuration.
2/14
Siemens ST 80 · 2009
The TD 100C permits:
• Display of message texts:
Up to 40 message texts (interrupts) with max. 4 variables
indicate the current operating states and can optionally be parameterized as requiring mandatory acknowledgment and additionally protected by a password. In addition, as many as
32 static messages, likewise with max. 4 variables, can be
configured. System texts are stored in the device in German,
English, French, Spanish and Italian. Various different character sets can also be selected; messages can also be stored in
the simplified Chinese script.
• Display and modification of process parameters:
Process parameters are shown on the display and can be
modified by means of the input keys, e.g. for temperature
settings or changes of speed.
• Setting of inputs and outputs:
One memory bit is assigned to each of the programmed function keys. These can then be set during operation, e.g. on startup, test and diagnostics. This enables motors, for example, to
be controlled without having to install any additional control
elements in the plant.
• Additional functions and features:
For example, processing of floating-point numbers, different
data blocks for the operation of several TDs on one CPU,
password protection for integrated SETUP menu, and
changeable variables.
• Activation of the TD 100C editing mode by the PLC:
Variables embedded in messages can be directly edited
without having to press the enter key or move the cursor over
the variable.
• Setting a PLC bit:
- Set bit:
On pressing a function key, a bit is set in the PLC. This must
be reset again by the user program.
- Momentary:
On pressing a function key a bit is set, and on releasing the
key the bit is deleted again.
• New character set (Greek, Latin2, Turkish) for supporting
additional foreign languages
Programming
The configuration data of the TD 100C is stored in the CPU of the
S7-200. The message texts and configuration parameters are
created with the STEP 7-Micro/WIN V4 programming software.
Additional parameterizing software is not required. The operator
panel front design is configured using the Keypad Designer
(component of STEP 7-Micro/WIN V4).
For the exchange of data with the TD 100C, special data areas
are reserved in the CPU of the S7-200. Via these data areas, the
TD 100C directly accesses the respective required functions of
the CPU. The user-friendly parameterization is performed by
means of a special TD Wizard in STEP 7-Micro/WIN V4.
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 100C
■ Technical specifications
■ Ordering data
Text Display TD 100C
Power supply
Input voltage
• Rated value (DC)
24 V; Supply from S7-200
communication interface
Input current
• Rated value at DC 24 V
Connecting cables
187.5 kBit/s
For connecting TD 100C or
TD 200C to S7-200
RS 485
Functionality
PPI
Yes
6ES7 901-3EB10-0XA0
For printing customized
keyboard layouts;
6 perforated foils per sheet;
10 sheets per packing unit
6ES7 272-1BF00-7AA0
Accessories
PPI
Number of nodes, max.
2
Blank foils
1st interface
Physics
6ES7 272-1BA10-0YA1
With individually configurable
control elements on the device
front;
for connecting to SIMATIC
S7-200; for use with STEP 7
Micro/WIN V4 and higher,
plug-in cable required
25 mA
MPI
Transmission speed (PPI), max.
Order No.
A
Text Display TD 100C
126; S7-200, OP, TP, TBP, PG/PC
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
Operator control and monitoring
A) Subject to export regulations: AL: N and ECCN: EAR99H
Display
• Type
LC display (reflecting)
• Number of lines
4
• Number of characters per line
12; characters/line: 12 or
16 characters/line: Chinese 8
• Font size
3.34 mm
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
Environmental requirements
Operating termperature
• max.
60 °C
Storage/transport temperature
• min.
-20 °C
• max.
70 °C
35,7
86,9
G_ST80_XX_00319
0 °C
76
• min.
Degree of protection
IP 65
Yes
Dimensions
Cabinet/switchboard strength
1.5 mm; 1.5 to 4 mm
Dimensions
Width
90 mm
Height
76 mm
Depth
36 mm; max. 44 mm with fittings
Mounting cutout, width
82 mm
Mounting cutout, height
69.5 mm
Weights
Weight, approx.
120 g
Siemens ST 80 · 2009
2/15
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 200
■ Overview
■ Design
The TD 200 is simply connected to the PPI interface of the
S7-200 using the supplied connecting cable. A separate power
supply is not required. It is also possible to connect several
TD 200 units to one S7-200.
2
• The user-friendly text display for the S7-200
• For control and monitoring:
Message text display, intervention in PLC program, setting of
inputs and outputs
• Direct connection to CPU interface using supplied cable or
incorporation into network (also via EM 277)
• No separate power supply required
• No separate parameterization software required
• Addressing and setting of contrast in supplied menu
■ Application
The TD 200 Text Display is the optimum solution for all HMI tasks
of SIMATIC S7-200.
It supports:
• Display of message texts
• Interventions in the control program, e.g. modification of
setpoints
• Setting of inputs and outputs, e.g. for switching a motor on
and off
2/16
Siemens ST 80 · 2009
The TD 200 features:
• Rugged plastics housing with degree of protection IP65
(front):
Increased watertightness due to absence of slots for labeling
strips
• Mounting depth 27 mm:
The TD 200 can be mounted without additional accessories in
control cabinets or operator panels, or used as a handheld
unit
• Backlit LC display;
readable even under unfavorable lighting
• Ergonomically designed input keys,
below which are programmable function keys
• Integrated interface for connection of cable
• Connection for optional power supply:
A power supply unit is required if the distance between the
TD 200 and S7-200 is more than 2.5 m. PROFIBUS cables are
then available instead of the connection cable
• Customized labeling strips:
The back of the housing has to be removed to mount the labeling strips. This must therefore be performed before the unit
is installed
■ Function
The TD 200 permits:
• Display of message texts:
Up to 80 message texts (alarms) with max. 6 variables display
current operating states and can be optionally parameterized
to require acknowledgment and can be additionally protected
by a password. Also up to 64 static alarms with up to 6 variables can be configured. System texts are stored in English,
German, French, Spanish and Italian in the unit. Various character sets can be selected, and messages can be additionally
saved in the simplified Chinese character set
• Display and modification of process parameters:
Process parameters are output on the display, and can be
modified using the input keys, e.g. for temperature settings or
modifications to speed
• Setting of inputs and outputs:
A memory bit is assigned to each of the 8 programmable function keys. These can then be set during operation, e.g. during
commissioning, testing and diagnostics. It is then possible
e.g. to control motors without having to install additional control elements in the system
• Additional functions and features:
E.g. processing of floating-point numbers, symbols for bar
graph display, various data blocks for operation of several
TD 200 displays on one CPU, password protection for integral
SETUP menu and modified variables
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 200
■ Function (continued)
• Activation of TD 200 editing mode by PLC:
Variables embedded in messages can be edited directly
without having to press the Enter key or to place the cursor at
the variable
• Setting a PLC bit:
- Set bit:
When a function key is pressed, a bit is set in the PLC.
This must be reset by the user program
- Momentary:
A bit is set when pressing a function key, and deleted
again when the key is released
• New character set (Greek, Latin2, Turkish) to support further
foreign languages
Programming
■ Technical specifications
Text Display TD 200
Power supply
Input voltage
• Rated value (DC)
24 V; Power supplied over the
S7-200 communications interface
or optional external power supply
unit; the CPU sensor power supply
(24 V DC) is not subjected to load
Input current
• Rated value at DC 24 V
120 mA
MPI
Transmission speed
(PPI), max.
The configuration data of the TD 200 are saved in the CPU of the
S7-200. The message text strings and configuration parameters
are created with the STEP 7 Micro/WIN configuration software of
V4 and higher. Additional parameterization software is not
required.
1st interface
Special data areas are reserved in the CPU of the S7-200 for
data exchange with the TD 200. The TD 200 directly accesses
the respectively required functions of the CPU via these data
areas. A separate TD 200 wizard in STEP 7 Micro/WIN V4 and
higher supports user-friendly parameter assignment.
PPI
Physics
187.5 kBit/s
RS 485
Functionality
• PPI
• Number of nodes, max.
Yes
126; S7-200, OP, TP, TBP, PG/PC
Operator control and monitoring
Display
• Type
LCD backlit
Operating/fault messages
• Number of lines
2
• Number of characters per line
20 characters/line: ASCII, Cyrillic;
10 characters/line: Chinese
• Font size
5 mm
Environmental requirements
Operating termperature
• min.
0 °C
• max.
60 °C
Storage/transport temperature
• min.
-40 °C
• max.
70 °C
Degree of protection
IP 65
Yes; at front
Dimensions
Cabinet/switchboard strength
0.3 mm; 0.3 to 4 mm
Dimensions
• Width
148 mm
• Height
76 mm
• Depth
27 mm
• Mounting cutout, width
138 mm
• Mounting cutout, height
68 mm
Weights
• Weight, approx.
250 g
Siemens ST 80 · 2009
2/17
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 200
■ Ordering data
Text Display TD 200
6ES7 272-0AA30-0YA1
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
for connection to SIMATIC S7200; can be used with STEP 7Micro/WIN V3.2 SP4 or higher,
incl. connecting cable
Connecting cables
6ES7 901-3EB10-0XA0
For connecting TD 100C or TD
200C to S7-200
28
148
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
76
A) Subject to export regulations: AL: N and ECCN: EAR99H
G_ST80_XX_00320
2
Order No.
A
TD 200
2/18
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 200C
■ Overview
■ Application
The TD 200C Text Display is the ideal solution for all HMI tasks
of the SIMATIC S7-200. The ability to print the surface of the
device individually allows it to be optimally adapted to the application environment.
It supports:
• Display of message texts
• Interventions in the control program, e.g. modification of
setpoints
• Setting of inputs and outputs, e.g. for switching a motor on
and off
■ Design
The TD 200C is simply connected to the PPI interface of the
S7-200 using the supplied connecting cable. A separate power
supply is not required. It is also possible to connect several
TD 200C to one S7-200.
• The user-friendly text display for the S7-200 with customizable
display
• For control and monitoring:
Message text display, intervention in PLC program, setting of
inputs and outputs
• Direct connection to CPU interface using supplied cable or
incorporation into network (also via EM 277)
• No separate power supply required
• No separate parameterization software required
• Frontpanel design can be individually selected
• Addressing and setting of contrast in supplied menu
The TD 200 features:
• Rugged plastics housing with degree of protection IP65
(front):
Increased watertightness due to absence of slots for labeling
strips
• Mounting depth 27 mm:
The TD 200C can be mounted without additional accessories
in control cabinets or operator panels, or used as a handheld
unit
• Backlit LC display:
Readable even under unfavorable lighting
• Integrated interface for connection of cable
• Connection for optional power supply:
A power supply unit is required if the distance between the
TD 200C and S7-200 is more than 2.5 m. PROFIBUS cables
are then available instead of the connection cable
• Individually designable user interface:
The control elements of the front of the device as well as the
design can be configured individually on a printable sheet.
The Keypad Designer (a component of STEP 7-Micro/WIN) is
used for configuration
Siemens ST 80 · 2009
2/19
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 200C
■ Function
2
■ Technical specifications
The TD 200C permits:
• Display of message texts:
Up to 80 message texts (alarms) with max. 6 variables display
current operating states and can be optionally parameterized
to require acknowledgment and can be additionally protected
by a password. Also up to 64 static alarms with up to 6 variables can be configured. System texts are stored in English,
German, French, Spanish and Italian in the unit. Various
character sets can be selected, and messages can be additionally saved in the simplified Chinese character set.
• Display and modification of process parameters:
process parameters are output on the display, and can be
modified using the input keys, e.g. for temperature settings or
modifications to speed.
• Setting of inputs and outputs:
A bit memory is assigned to each of the programmable function keys. These can then be set during operation, e.g. during
commissioning, testing and diagnostics. It is then possible
e.g. to control motors without having to install additional
control elements in the system.
• Additional functions and features:
e.g. processing of floating-point numbers, symbols for
bargraph display, various data blocks for operation of several
TDs on one CPU, password protection for integral SETUP
menu and modified variables.
• Activation of TD 200 editing mode by PLC:
Variables embedded in messages can be edited directly
without having to press the Enter key or to place the cursor at
the variable.
• Setting a PLC bit:
- Set bit:
When a function key is pressed, a bit is set in the PLC. This
must be reset by the user program.
- Momentary:
A bit is set when pressing a function key, and deleted again
when the key is released.
• New character set (Greek, Latin2, Turkish) to support further
foreign languages
• Programming the S7-200 memory module
• Selection of operating mode of the CPU (RUN/STOP)
• Editing the V memory area
Text Display TD 200C
Power supply
Input voltage
• Rated value (DC)
Input current
• Rated value at DC 24 V
120 mA
MPI
Transmission speed (PPI), max.
187.5 kBit/s
1st interface
Physics
RS 485
Functionality
• PPI
Yes
PPI
• Number of nodes, max.
126; S7-200, OP, TP, TBP, PG/PC
Operator control and monitoring
Display
• Type
LCD backlit
Operating/fault messages
• Number of lines
2
• Number of characters per line
20 caracters/line: ASCII, Cyrillic;
10 caracters/line: Chinese
• Font size
5 mm
Environmental requirements
Operating termperature
• min.
0 °C
• max.
60 °C
Storage/transport temperature
• min.
-20 °C
• max.
70 °C
Degree of protection
Programming
IP 65
The configuration data of the TD 200C are saved in the CPU of
the S7-200. The message text strings and configuration parameters are created with the STEP 7 Micro/WIN V4 programming
software. Additional parameterization software is not required.
The Keypad Designer (a component of STEP 7-Micro/WIN V4) is
used to configure the operating front design.
Dimensions
Special data areas are reserved in the CPU of the S7-200 for
data exchange with the TD 200C. The TD 200C directly accesses the respectively required functions of the CPU via these
data areas. A separate TD 200 wizard in STEP 7 Micro/WIN V4
supports user-friendly parameter assignment.
24 V; Power supplied over the
S7-200 communications interface
or optional external power supply
unit; the CPU sensor power supply
(24 V DC) is not subjected to load
Cabinet/switchboard strength
Yes; at front
0.3 mm; 0.3 to 4 mm
Dimensions
Dimensions
• Width
148 mm
• Height
76 mm
• Depth
28 mm
• Mounting cutout, width
138 mm
• Mounting cutout, height
68 mm
Weights
• Weight, approx.
2/20
Siemens ST 80 · 2009
200 g
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 200C
■ Ordering data
Text Display TD 200C
Order No.
A
6ES7 272-1AA10-0YA1
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
With individually configurable
control elements on the device
front;
for connecting to SIMATIC
S7-200; for use with STEP 7
Micro/WIN V4 and higher, incl.
plug-in cable
2
6ES7 901-3EB10-0XA0
A
76
For connecting TD 100C or
TD 200C to S7-200
Blank foils
28
148
Connecting cables
6ES7 272-1AF00-7AA0
G_ST80_XX_00321
For printing customized
keyboard layouts;
3 perforated faceplates per
sheet; 10 sheets per packing unit
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
A) Subject to export regulations: AL: N and ECCN: EAR99H
TD 200C
Siemens ST 80 · 2009
2/21
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 400C
■ Overview
■ Application
The TD 400C Text Display is the optimal solution for all operator
control and monitoring tasks of the SIMATIC S7-200. The customizable operator interface enables optimal adaptation of the
device to the surroundings in which it is used.
2
It enables:
• Display of message texts
• Intervention in the control program, e.g. setpoint changes
• Setting of inputs and outputs, e.g. for switching a motor on
and off
Compatibility with the TD 100C, TD 200 and
TD 200C Text Displays:
The TD 400C Text Display is not compatible with existing Text
Displays (different mounting dimensions, configuration cannot
be adopted).
■ Design
• Multi-screen workstation and extremely good readability
thanks to backlit four-line display
• Customizable operator interface with 15 tactile keys
• Acoustic and visual feedback from key operation
• Optimal support of the S7-200:
- Direct connection to the S7-200 interface via supplied cable
- No separate power supply required
- Parameterization with STEP 7-Micro/WIN V4 SP6
2/22
Siemens ST 80 · 2009
The TD 400C is connected to the S7-200 using the supplied
connecting cable. A separate power supply is not required. It is
also possible to connect several TD 400Cs to one S7-200.
The TD 400C has the following:
• 3.7" STN LCD backlit display:
Up to 4 text lines can be configured
• Rugged plastic housing in degree of protection IP65 (on front),
IP20 (on rear):
Increased waterproofing because there are no slots for
labeling strips
• Installation depth of 31 mm:
The TD 400C can be installed in control cabinets or used as a
handheld device without any other accessories
• Customizable operator interface:
The design (colors, pictures, text, etc.) of the operator
interface can be individually designed. Configuration is
carried out with the Keypad Designer (component part of
STEP 7-Micro/WIN)
• Configuration of tactile keys:
Up to 15 permanently positioned, tactile keys can be assigned
numerous functions (e.g. direction keys, messages,
Set PLC bit)
• Connection for optional power supply:
A power supply is required at a distance of more than 2.5 m
between the TD 400C and S7-200. PROFIBUS bus cables are
then available in place of the supplied connecting cable
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 400C
■ Function
• Display of message texts:
Up to 80 message texts (alarms) with up to 6 variables display
current operating states and can be optionally parameterized
as requiring acknowledgement and additionally protected by
a password. In addition, up to 64 static messages, also with
up to 6 variables, can be configured. Message texts can be
displayed in two lines or four lines depending on the character
size set. Four lines with 12 Chinese characters or 24 ASCII
characters per line. Two lines with 8 Chinese characters or
16 ASCII characters per line.
• Display and modification of process parameters:
Process parameters are shown on the display and can be
modified using the input keys, e.g. for setting temperatures or
changing speeds.
• Setting inputs and outputs:
A memory bit is assigned to each of the programmable
function keys. These bits can then be set during operation,
e.g. at startup, and during test and diagnostics. In this way,
motors can be controlled, for example, without having to install
additional operator elements in the system.
• Additional functions and features:
For example, processing of floating-point numbers, different
data blocks for operating several TDs on one CPU, password
protection for integral SETUP menu, and modifiable variables.
• Activation of the TD 400C editing mode by the PLC:
Variables embedded in messages can be edited direct
without pressing the Enter key and moving the cursor to the
variable.
• Setting a PLC bit:
- Set bit:
When a function key is pressed, a bit is set in the PLC. This
must be reset again via the user program.
- Momentary:
When a function key is pressed, a bit is set, and when the key
is released, the bit is deleted.
• New character set (Greek, Latin2, Turkish) for supporting further languages
• Programming of the S7-200 memory submodule
• Selecting the operating mode of the CPU (RUN/STOP)
• Editing of the V memory area
■ Technical specifications
Text Display TD 400C
Supply voltage
Supply voltage
24 V DC
Permissible range
DC
2
Configuration
Configuration tool
MicroWin
(to be ordered separately)
Display
Display type
STN, black/white
Size
3.7"
Resolution (WxH in pixel)
192 x 64
MTBF backlighting (at 25 °C)
about 20,000 hours
Operating mode
Operating elements
Membrane keyboard
Function keys, programmable
15 function keys
Membrane keyboard
Yes
Ambient conditions
Temperature
• Operation
0 °C to +50 °C
• Transport, storage
-20 °C to +60 °C
Degree of protection
Front
IP65, NEMA 4, NEMA 4x,
NEMA 12 (when installed)
Rear
IP20
Certifications & Standards
Certifications
CE, FM Class I Div. 2, UL, C-TICK,
NEMA 4, NEMA 4x, NEMA 12
Interfaces
Interfaces
1 x RS485 (max. 187.5 Mbit/s)
Weights
Weight
0.33 kg
Programming
The configuration data of the TD 400C is stored in the CPU of the
S7-200. The message texts and the configuration parameters
are created with the STEP 7-Micro/WIN V4 SP6 programming
software. Additional parameterization software is not required.
The operating front design is configured with the Keypad
Designer (component part of STEP 7-Micro/WIN V4 SP6).
Special data areas are reserved in the CPU of the S7-200 for
data exchange with the TD 400C. The TD 400C accesses each
of the required functions of the CPU direct via these data areas.
User-friendly parameterization takes place via a dedicated
TD 400 Wizard in STEP 7-Micro/WIN V4 SP6.
Siemens ST 80 · 2009
2/23
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
Text Display TD 400C
■ Ordering data
TD 400C Text Display
6AV6 640-0AA00-0AX1
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
With customizable operator
interface on the device front;
for connecting to SIMATIC
S7-200; can be used from STEP
7-Micro/WIN V4 SP6, incl.
connecting cable
Connecting cables
31
174
6ES7 901-3EB10-0XA0
For connecting TD 100C/
TD 200C or TD 400C to S7-200
Blank foils
102
6AV6 671-0AP00-0AX0
For printing customized
keyboard layouts;
2 perforated films per sheet;
10 sheets per pack
G_ST80_XX_00322
2
Order No.
A
Accessories
Accessories for
supplementary ordering
see HMI accessories,
from page 2/158
A) Subject to export regulations: AL: N and ECCN: EAR99H
2/24
Siemens ST 80 · 2009
TD 400C
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
SIMATIC OP 73micro
■ Overview
■ Benefits
•
•
•
•
High-contrast display for good readability
Large keys for high operational safety
Simple handling and configuring
Fast configuring and start-up
- Service-friendly thanks to maintenance-free design
(no battery) and long service life of the backlighting
• Graphics library is available complete with ready-to-use
display objects
• Can be used worldwide:
- 32 languages can be configured (including Asiatic and
Cyrillic character sets)
- Up to 5 languages are selectable online
■ Application
• Operator Panel for controlling and monitoring machines and
systems
• Graphics in a new dimension: small and smart
• Pixel-graphics 3" LCD, monochrome
• 8 system keys, 4 user-configurable function keys
• Specific to the SIMATIC S7-200:
Communication with the controller takes place via the
integrated interface (point-to-point)
• Connection to the controller via MPI or PROFIBUS DP cable
OP 73micro Operator Panels can be used wherever machines
and systems are controlled and monitored locally – in production, process and building automation alike. They are used in all
types of sectors and applications.
The OP 73micro has been designed specifically for use with the
SIMATIC S7-200.
Compatibility
• Same mounting cutout as for OP3 and TD 200
■ Design
•
•
•
•
•
•
3" LCD, 160 x 48 pixels, monochrome
8 system keys, 4 freely configurable function keys
Numeric and alphanumeric input using cursor control keys
Compact design with small installation depth
Rugged plastic housing
The front is resistant to various oils, greases and standard
detergents
• Plug-in terminals for connecting a 24 V DC power supply
• RS 485 interface for connecting the MPI connecting cable or
the PPI adapter
Siemens ST 80 · 2009
2/25
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
SIMATIC OP 73micro
■ Function
2
■ Technical specifications
• Input/output fields
for displaying and changing process parameters
• Function keys
for direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on function keys
• Graphics
can be used as icons instead of text to "label" function keys or
buttons. They can also be used as simple on-screen graphics.
In the configuration tool, a library is available containing an extensive range of graphics and a wide variety of objects. All editors with an OLE interface can be used as graphics editors
(such as PaintShop, Designer or CorelDraw)
• Predefined
for labeling function keys, process images and process
values in different font sizes
• Bars
for the graphical display of dynamic values.
• Language selection during runtime
- 5 online languages, 32 configuration languages incl.
Asian and Cyrillic character sets
• User administration (security) according to the requirements
of the various sectors
- Authentication using password
• Signaling system
- Discrete alarms
- Analog messages
- Freely definable message classes (e.g., status/fault
messages) for definition of acknowledgment response and
display of message events
- Message history
• Help texts
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Indicator light
for machine and plant status indication
• Scheduler for global function execution
• Template concept
Creation of picture templates (picture elements configured in
the template appear in every image)
• User-friendly maintenance and configuration thanks to:
- Backup and restoration of configuration, operating system
and firmware on a PC using ProSave
- Configuration download serially via RS485
- Individual contrast settings
- No batteries are necessary
Configuring
SIMATIC WinCC flexible Micro, Compact, Standard or
Advanced engineering software Version 2004 SP1 and higher
plus HSP is used for configuration.
For more information about engineering software, see HMI software/engineering software SIMATIC WinCC flexible.
A PC/PPI adapter cable is needed to download the configuration.
■ Integration
Supply voltage
24 V DC
Permissible range
+20.4 V to +28.8 V DC
Rated current
0.1 A
Memory
Type of storage
• Type
Flash
• Memory usable for project
data/Options
128 KB usable memory for user
data
Time
Clock
• Type
Software clock, not battery backed
Configuration
Configuration tool
WinCC flexible Micro Version 2004
SP1, HSP or higher (to be ordered
separately)
Display
Display type
STN, Black/white
Size
3"
Resolution (WxH in pixel)
160 x 48
MTBF backlighting (at 25 °C)
about 100,000 hours
Operating mode
Operating elements
Membrane keyboard
Function keys, programmable
4 function keys
System keys
8
Touchscreen
No
Numeric/alphabetical input
Yes / Yes
Connection for mouse/keyboard/barcode reader
-/-/-
Ambient conditions
Mounting position
Vertical
maximum permissible angle of
incliniation without external
ventilation
+/- 80 °
max. relative humidity (in %)
90%
Temperature
• Operation (vertical installation)
0 °C to +50 °C
• Operation (max. tilt angle)
0 °C to +40 °C
• Transport, storage
-20 °C to +60 °C
Degree of protection
Front
IP65, NEMA 4x, (when installed)
Rear
IP20
Certifications & Standards
Certifications
CE, GL, ABS, BV, DNV, LRS, UL,
CSA, cULus, C-TICK, NEMA 4x
interfaces
Interfaces
1 x RS485 (max. 187.5 Mbit/s)
Operating systems
The OP 73micro can be connected to all SIMATIC S7-200 CPUs
using the standard MPI bus cables or PROFIBUS DP cables
(integration into networks possible).
Operating system
For further information see "System interfaces"
Siemens ST 80 · 2009
LINUX
Processor
Processor
Note:
2/26
SIMATIC OP 73micro
Supply voltage
ARM
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
SIMATIC OP 73micro
■ Technical specifications (continued)
SIMATIC OP 73micro
Functionality under
WinCC flexible
Task planner
Yes
Help system
Yes
Status/control
Not possible
Message system
■ Ordering data
SIMATIC OP 73micro
Order No.
C
6AV6 640-0BA11-0AX0
F
6AV6 650-0BA01-0AA0
Operator panel for connection to
the SIMATIC S7-200, with
3" display, monochrome incl.
mounting accessories
OP 73micro starter package
Consisting of:
• OP 73micro Operator Panel
• Number of messages
250
• Bit messages
Yes
• Analog messages
Yes
• Message buffer
Ring buffer (n x 100 entries)
Number of process images
• Process images
250
• Variables
500
• Limit values
Yes
• Multiplexing
Yes
Image elements
• SIMATIC WinCC flexible Micro
engineering software
• SIMATIC HMI Manual
Collection, 5 languages
(English, French, German,
Italian, Spanish), comprising:
all currently available user
manuals, manuals and
communication manuals for
SIMATIC HMI
• MPI cable (5 m)
(for test purposes)
Configuration
• Text objects
1,000 text elements
• Graphics object
Bit maps, icons, icon (full-screen)
• dynamic objects
Bar graphs
Lists
with SIMATIC WinCC flexible
see HMI Software
Documentation (to be ordered separately)
Operating Instructions
OP 73micro/TP 177micro
• Text lists
150
• German
6AV6 691-1DF01-0AA0
• Graphics list
0
• English
6AV6 691-1DF01-0AB0
• Libraries
Yes
• French
6AV6 691-1DF01-0AC0
• Italian
6AV6 691-1DF01-0AD0
6AV6 691-1DF01-0AE0
Security
• Number of user groups
1
• Spanish
• Passwords exportable
Yes
• Number of users
1
User Manual
WinCC flexible Micro
• German
6AV6 691-1AA01-3AA0
No
• English
6AV6 691-1AA01-3AB0
• French
6AV6 691-1AA01-3AC0
• Italian
6AV6 691-1AA01-3AD0
• Spanish
6AV6 691-1AA01-3AE0
US American (English)
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
• Online languages
5
Electronic documentation,
on DVD
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S, CZ
/ SK, TR, H
• Fonts
WinCC flexible Standard, symbol
languages
Data medium support
• Multi Media Card
Recording
• Printer driver
-
Fonts
• Keyboard fonts
Languages
Transfer (Upload/Download)
• Transfer of configuration
2
serial
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
Process coupling
• Connection to controller
for S7-200, see section on "System
interfaces"
Expandability/openness
• Open Platform Program
No
Dimensions
Front of enclosure (W x H)
154 mm x 84 mm
Mounting cutout/Device depth
(W x H/D) in mm
138 mm x 68 mm / 28.5 mm
device depth
B) Subject to export regulations: AL: N and ECCN: EAR99S
Weights
• Weight
0.25 kg
C) Subject to export regulations: AL: N and ECCN: EAR99T
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
Siemens ST 80 · 2009
2/27
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
SIMATIC OP 73micro
■ Dimensions
■ More information
Additional information is available in the Internet under:
All specifications in mm. Panel cutout see technical specifications.
http://www.siemens.com/panels
2
Note
154
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
G_ST80_XX_00144
67,7
84
28,5
2/28
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
SIMATIC TP 177micro
■ Overview
■ Benefits
• Can even be used where installation space is restricted
thanks to vertical installation
• Fast configuring and start-up
• Service-friendly thanks to maintenance-free design and the
long service life of the backlighting
• Graphics library is available complete with ready-to-use
display objects
• Can be used worldwide:
- 32 languages can be configured (including Asiatic and
Cyrillic character sets)
- Up to 5 languages are selectable online
■ Application
TP 177micro Touch Panels can be used wherever small
machines and systems are controlled and monitored locally – in
production, process and building automation alike. They are
used in all types of sectors and applications.
• Touch Panel for operator control and monitoring of small
machines and plants
• Low-cost entry-level product in the category of touch panels
with graphics capability and all the basic functions required
for simple tasks
• Pixel graphics 5.7" STN touch screen (analog/resistive),
Bluemode (4 levels)
• Specially for SIMATIC S7-200:
Communication to the PLC through the integrated interface
over a point-to-point link
• Connection to the PLC over MPI or PROFIBUS DP cable
• SIMATIC TP 177micro is the innovative successor to the Touch
Panels SIMATIC TP 070/TP 170micro
The TP 177micro has been designed specifically for use with the
SIMATIC S7-200. With fast response times, it is also ideal for jog
mode.
Compatibility with TP 070/TP 170micro
• Same mounting cutout as the TP 070/TP 170micro.
■ Design
•
•
•
•
•
•
•
•
•
1)
5.7" STN display, CCFL1) backlit, Bluemode (4 levels)
Resistive analog Touch
Compact design with small installation depth
Rugged plastic housing
The front is resistant to various oils, greases and standard detergents
Numeric system keyboard for decimal, binary and hexadecimal number formats
On-screen alphanumeric keyboard
Plug-in terminals for connecting a 24 V DC power supply
RS 485 interface for connection of the MPI cable or the PPI
adaptor
Cold Cathode Fluorescence Lamps
Siemens ST 80 · 2009
2/29
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
SIMATIC TP 177micro
■ Function
2
■ Integration
• Input/output fields
for displaying and changing process parameters
• Buttons
for direct triggering of functions and actions. Up to 16
functions can be configured simultaneously on buttons
• Graphics
can be used as icons instead of text to "label" function keys or
buttons. They can also be used as background displays
(wallpaper).
In the configuration tool, a library is available containing
extensive graphics and a wide variety of objects. All editors
with an OLE interface can be used as graphics editors (such
as PaintShop, Designer or CorelDraw).
• Vector graphics
Simple geometric basic forms (line, circle and rectangle) can
be created direct in the configuring tool
• Predefined texts
for labeling function keys, process images and process
values in any character size
• Bars
for the graphical display of dynamic values
• Changing languages
- 5 online languages, 32 configuration languages incl. Asian
and Cyrillic character sets
• User administration (security)
- Authentication using password
• Signaling system
- Discrete alarms
- Analog messages
- Freely definable message classes (e.g., status/fault
messages) for definition of acknowledgment response
and display of message events
- Message history
• Help texts
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Indicator light
for machine and plant status indication
• Template concept
Creation of picture templates (picture elements configured in
the template appear in every image)
• User-friendly maintenance and configuration thanks to:
- Backup and restoration of configuration, operating system
and firmware on a PC using ProSave
- Configuration download serially via RS485
- Individual contrast setting and calibration
- Clean screen
- No batteries are necessary
Configuring
SIMATIC WinCC flexible Micro, Compact, Standard or
Advanced engineering software Version 2004 SP1 and higher
plus HSP is used for configuration. For more information about
engineering software, see HMI software/engineering software
SIMATIC WinCC flexible. A PC/PPI adapter cable is needed to
download the configuration.
2/30
Siemens ST 80 · 2009
The TP 177micro can be connected to all SIMATIC S7-200-CPUs
using the standard MPI bus cables or PROFIBUS DP cables
(integration into networks possible).
Note:
For further information see "System interfaces".
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
SIMATIC TP 177micro
■ Technical specifications
SIMATIC TP 177micro
Supply voltage
Supply voltage
24 V DC
Permissible range
+20.4 V to +28.8 V DC
Rated current
0.24 A
Memory
Memory usable for project
data/Options
Flash
256 KB
Time
Clock
• Type
Yes
Help system
Yes
Status/control
Not possible
2
• Number of messages
500
• Bit messages
Yes
• Analog messages
Yes
• Message buffer
Ring buffer (n x 128 entries)
Number of process images
Software clock, not battery backed
Configuration
Configuration tool
Task planner
Message system
Type of storage
• Type
SIMATIC TP 177micro
Functionality under
WinCC flexible
WinCC flexible Micro Version 2004
SP1, HSP or higher (to be ordered
separately)
• Process images
250
• Variables
250
• Limit values
Yes
• Multiplexing
Yes
Image elements
Display
STN, 4 shades of blue
• Text objects
500 text elements
Size
5.7"
• Graphics object
Bit maps, icons, icon (full-screen),
vector graphics
Resolution (WxH in pixel)
320 x 240
• dynamic objects
Diagrams, bar graphs
MTBF backlighting (at 25 °C)
about 50,000 hours
Display type
Operating mode
Operating elements
Touch screen
Function keys, programmable
None
System keys
None
Touchscreen
analog, resistive
Numeric/alphabetical input
Yes / Yes
Ambient conditions
Mounting position
Vertical
+/- 35 °
Maximum permissible angle of
incliniation without external ventilation
Max. relative humidity (in %)
90%
Temperature
Lists
• Text lists
150
• Graphics list
100
• Libraries
Yes
Security
• Number of user groups
1
• Passwords exportable
Yes
• Number of users
1
Data medium support
• Multi Media Card
No
Recording
• Printer driver
-
Fonts
• Operation (vertical installation)
0 °C to +50 °C
• Keyboard fonts
• Operation (max. tilt angle)
0 °C to +40 °C
Languages
• Transport, storage
-20 °C to +60 °C
• Online languages
5
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
WinCC flexible Standard, symbol
languages
Degree of protection
Front
IP65, NEMA 4x, (when installed)
Rear
IP20
Certifications & Standards
Certifications
CE, GL, ABS, BV, DNV, LRS, FM
Class I Div. 2, UL, CSA, cULus,
EX-Zone 2 (available soon),
EX-Zone 22 (available soon),
C-TICK, NEMA 4x
interfaces
Interfaces
• Transfer of configuration
serial
Process coupling
• Connection to controller
for S7-200, see section on
"System interfaces"
Expandability/openness
LINUX
• Open Platform Program
No
Dimensions
Processor
Processor
Transfer (Upload/Download)
1 x RS485 (max. 187.5 Mbit/s)
Operating systems
Operating system
US American (English)
ARM
Front of enclosure (W x H) in mm
212 x 156
Mounting cutout/Device depth
(W x H/D) in mm
198 x 142 / 45
Weight
0.75 kg
Siemens ST 80 · 2009
2/31
© Siemens AG 2008
Operator Control and Monitoring Devices
Micro Panels
SIMATIC TP 177micro
■ Ordering data
SIMATIC TP 177micro
6AV6 640-0CA11-0AX1
F
6AV6 650-0DA01-0AA0
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
Touch Panel for connection to the
SIMATIC S7-200, 5.7" STN display
TP 177micro starter package
Consisting of:
44
212
• TP 177micro Touch Panel
6,2
• SIMATIC HMI Manual Collection
(DVD),
5 languages (English, French,
German, Italian, Spanish),
comprising: all currently available user manuals, manuals and
communication manuals for
SIMATIC HMI
G_ST80_XX_00143
140
• SIMATIC WinCC flexible Micro
engineering software
156
2
Order No.
C
• MPI cable (5m)
(for test purposes)
Configuration
with SIMATIC WinCC flexible
see HMI Software
Documentation (to be ordered separately)
Operating Instructions
OP 73micro, TP 177micro
Additional information is available in the Internet under:
• German
6AV6 691-1DF01-0AA0
• English
6AV6 691-1DF01-0AB0
• French
6AV6 691-1DF01-0AC0
• Italian
6AV6 691-1DF01-0AD0
• Spanish
6AV6 691-1DF01-0AE0
WinCC flexible Micro
User Manual
• German
6AV6 691-1AA01-3AA0
• English
6AV6 691-1AA01-3AB0
• French
6AV6 691-1AA01-3AC0
• Italian
6AV6 691-1AA01-3AD0
• Spanish
6AV6 691-1AA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian, Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
B) Subject to export regulations: AL: N and ECCN: EAR99S
C) Subject to export regulations: AL: N and ECCN: EAR99T
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
2/32
Siemens ST 80 · 2009
■ More information
http://www.siemens.com/panels
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels
Introduction
■ Overview
SIMATIC Mobile Panel
• Mobile operator panel for direct operator control of the plant
and machine from any point
• Supports optimized monitoring of the workpiece or process
providing at the same time direct access and direct line of
sight to the operator panel
• Flexible application with simple reconnection during operation
(Mobile Panel 177 and Mobile Panel 277) or
• Wireless freedom (Mobile Panel 277(F) IWLAN)
• Pixel-graphics, brilliant color display with touch screen
(analog/resistive)
• PROFIBUS or PROFINET communication, PROFINET through
WLAN with Mobile Panel 277(F) IWLAN
• Freely configurable and inscribable function keys (with LED)
(not on Mobile Panel 277 10")
SIMATIC Mobile Panel 177 and SIMATIC Mobile Panel 277
• Two three-stage enabling buttons;
Optional versions include:
- STOP pushbutton
- STOP button, handwheel, key-operated switch and two
illuminated pushbuttons (not for Mobile Panel 277 10")
• Communication is supported via a serial link, MPI/PROFIBUS
or PROFINET
• Connection point recognition for local identification of the
device based on the connection point ID
• Fast system availability after plugging into the connectivity
boxes
• Connected to the PLC and power supply via the junction box
and the connecting cable
SIMATIC Mobile Panel 277 (F) IWLAN
• Wireless, mobile operator panel for flexible and locationindependent system and machine operation
• WLAN communication in accordance with IEEE 802.11 a (b/g)
and support of PROFINET
• Powerful batteries and flexible concept for changing permit
battery replacement "on the fly" without interrupting operation
• Effective range limitation and the local identification of the
device by using transponder technology
• Optional variants with: Handwheel, key switch and illuminated
pushbutton
• Fail-safe operator controls of the SIMATIC Mobile Panel
277F IWLAN using PROFIsafe:
- Two three-stage enabling buttons
- Emergency stop button
IWLAN Access Points SCALANCE W for SIMATIC Mobile
Panel 277(F) IWLAN
• The Access Points of the product line SCALANCE W-780 are
ideally suited for setting up Industrial Wireless LAN (IWLAN)
radio networks for 2.4 GHz and 5 GHz with data rates of up to
54 Mbit/s; they can be used for all applications that require a
high degree of operational reliability, even under extremely
harsh ambient conditions
• Suitable for any application:
- SCALANCE W-788 for cabinet-free installation
- SCALANCE W-786 for cabinet-free installation, also with
integral antennas
- SCALANCE W-784 for installation in control cabinets or
integration into devices
• Wireless communication suitable for use in applications with
high real-time and reliability requirements, such as
PROFINET, PROFIsafe or video
• Standard-compliant thanks to IEEE 802.11 support, additional
functional expansions especially for use with increased
reliability
• Effective encryption mechanisms protect against unauthorized access, spying, tapping, and corruption
• The SINEMA E engineering tool, wizards and online help
support planning, simulation, configuration and documentation; easy management with the web server and SNMP
• Fast commissioning of the Access Points thanks to the
optional swap medium PRESET-PLUG and fast device
replacement in the event of a fault thanks to the optional swap
medium C-PLUG (Configuration Plug)
• Accessories such as antennas, connectors, cables incl.
RCoax cables (radiating cables) that are tuned to one
another for a reliable radio link.
■ Benefits
• Flexible connection to the process, cabled or wireless
• Increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• Fast and accurate setup as well as positioning
• Reliable operation with perfected safety concept
• Ergonomic, compact and light-weight
• Rugged for industrial use
• Integral component of Totally Integrated Automation (TIA):
• Graphics library available with off-the-shelf picture objects
• The data in the message buffer is in retentive memory
• Can be used worldwide:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
- Up to 16 online languages can be directly switched over on
the Mobile Panel
• Reduction of service and commissioning costs through:
- Backup/restoration via a process interface or optionally via a
standard multi-media card
- Transfer of the configuration with automatic transfer
recognition via all device interfaces
- Long service life of the backlighting
• Simple engineering supported by comprehensive documentation on the SIMATIC HMI Manual Collection DVD
Siemens ST 80 · 2009
2/33
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels
Introduction
■ Application
2
Regardless of the industry or application, if mobility is required
for the on-site control and monitoring of machines and plants,
SIMATIC mobile panels offer some crucial advantages:
The machine operators or commissioning engineers are able to
work exactly where they have the best view of the workpiece or
process.
Even for larger production facilities, complex or enclosed
machines, long materials handling or production lines and conveyor systems, mobile operator panels allow fast and precise
setting up and positioning during commissioning. They also
ensure shorter downtimes during retooling, maintenance or
repairs.
■ Design
• Ergonomic and compact with different holding and gripping
points (suitable for right-handed and left-handed personnel)
• Pixel-graphics, brilliant color display with touch screen
(analog/resistive)
• Freely configurable and inscribable function keys (with LED)
(not on Mobile Panel 277 10")
• The front is resistant to various oils, greases and standard
detergents
• Extremely imnpact-resistant due to twin-wall construction and
rounded encosure
• Dust-proof and jet-proof casing with degree of protection IP65
on all sides
• Slot for a standard MultiMediaCard for configuration backup
and restoring or for storing recipes
• Two three-stage enabling buttons
• Optional variants with
- STOP pushbutton or
- STOP button, handwheel, key-operated switch and
illuminated pushbutton (not on Mobile Panel 277 10")
- The STOP pushbutton is secured specifically with a
"protective collar".
If the STOP pushbutton is looped into the emergency-stop
circuit, its function is equivalent to an emergency stop.
• Integrated serial, MPI and PROFIBUS interface (up
to 12 Mbit/s)
or
• Integral Ethernet (PROFINET) interface (up to 100 Mbit/s)
• Connection to the PLC via the rugged and reliable junction
boxes with degree of protection IP65:
- "Basic" junction box: Enables the STOP pushbutton to be
integrated into the safety circuit
- "Plus" junction box: Enables the STOP pushbutton to be
integrated into the safety circuit without interruption when
disconnecting the device. The emergency stop circuit
remains closed regardless of whether a Mobile Panel is
plugged in or not. If the Mobile Panel is disconnected during
operation, the emergency stop circuit in the junction box
Plus is automatically closed which prevents triggering of the
emergency stop circuit.
• Fast system availability after plugging into the junction boxes
- An optional rechargeable battery pack can be used to avoid
restarting of the Mobile Panel (following brief disconnection
from the junction box).
• Detection of the connection point can be used to perform
machine-specific HMI authorizations or actions depending on
the selected connection point
2/34
Siemens ST 80 · 2009
Sophisticated safety concept
The two enabling buttons (acc. to EN 60204-1) with three
switching steps each ensure the protection of personnel and
machines in critical situations. They are built into into the rear
handle.
The STOP pushbutton (acc. to EN 60204-1) is hard-wired and
positively latches when pressed. It can be looped into the emergency-stop circuit of a plant in which case it takes on the functionality of an emergency stop pushbutton, but is distinct with its
gray color. This ensures that it cannot be mistaken for the emergency stop equipment. This is especially important when the
Mobile Panel is not connected to the machine. SIMATIC Mobile
Panels offer the option of making safety functions available on a
mobile basis at any point of a machine or plant.
STOP pushbuttons and enabling buttons are implemented
according to safety regulations with two circuits and comply with
the requirements of Safety Category 3 according to EN 954-1.
Innovative connection concept
The Mobile Panel is simply plugged into the junction box
wherever it is needed in the plant and is immediately ready for
use. The junction box can be installed anywhere, even outside
the control cabinet. It ensures fault-free plugging and unplugging during normal operation and, therefore, allows the operatorcontrol location to be easily and safely changed when several
connection points are available in a plant or machine.
The location of a Mobile Panel can be clearly identified by
setting an ID number on the junction box. This identifier permits
the user to configure Mobile Panels in such a way that, for example, the user interface changes according to the connection
point. The Mobile Panel establishes the connection to the controllers after being plugged into the junction boxes and following
a short start-up period. An optional rechargeable battery pack
can be used to avoid restarting of the Mobile Panel (following
brief disconnection from the junction box).
Configuration options with emergency stop wiring
Panels with a STOP pushbutton can be integrated into the emergency stop circuit of a machine or plant via the junction box.
When the STOP pushbutton on the Mobile Panel is pressed, the
emergency stop function is activated. The STOP pushbutton on
the Mobile Panel supplements but does not replace the emergency stop equipment installed on the machine according to
EN 418. When the Mobile Panel is unplugged, "Plus" versions of
the junction box automatically close the emergency stop circuit,
thereby ensuring safe and fault-free changeover (swapping).
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels
Introduction
■ Design (continued)
Connection at one point of the machine
When the "Basic" junction box variant is used, unplugging the
Mobile Panel interrupts the emergency stop circuit and, therefore, triggers the emergency stop function.
This configuration is, therefore, best suited for applications in
which the Mobile Panel is connected to a fixed point on the
machine (example configuration: Mobile Panel 177).
2
:LULQJLQWRWKH(PHUJHQF\6WRSFLUFXLWZLWKFRQQHFWLRQER[%DVLF'3RU31
0RELOH3DQHOSOXJJHGLQ
(PHUJHQF\6WRSFLUFXLWFORVHG
0RELOH3DQHOGLVFRQQHFWHG (PHUJHQF\6WRSFLUFXLWRSHQ
352),1(7
352),%86
03,
&RQQHFWLRQER[
%DVLF'3RU31
0RELOH3DQHO
ZLWK6723EXWWRQ
*B67B;;B
(PHUJHQF\6WRSFLUFXLW
Flexible connection at various points on a machine or in a plant
If a Mobile Panel with a STOP pushbutton is used in combination
with a "Plus" junction box, a configuration is possible in which the
Mobile Panel can be used flexibly and is also looped into the
emergency stop circuit. The emergency stop circuit remains
closed regardless of whether a Mobile Panel is plugged into a
junction box or not.
When the Mobile Panel is plugged in, the equipment is looped
into the emergency stop circuit and when the STOP pushbutton
is pressed, the circuit will be interrupted and the emergency
stop function triggered. If the Mobile Panel is unplugged during
operation, the emergency stop circuit is automatically closed in
the "Plus" junction box variant (example configuration: Mobile
Panel 177).
$XWRPDWLFFORVLQJRIWKH(PHUJHQF\6WRSFLUFXLWE\FRQQHFWLRQER[3OXV'3RU31
0RELOH3DQHOSOXJJHGLQ
(PHUJHQF\6WRSFLUFXLWFORVHG
0RELOH3DQHOGLVFRQQHFWHG (PHUJHQF\6WRSFLUFXLWFORVHG
352),1(7
352),%86
03,
&RQQHFWLRQER[
3OXV'3RU31
0RELOH3DQHO
ZLWK6723EXWWRQ
*B67B;;B
(PHUJHQF\6WRSFLUFXLW
Siemens ST 80 · 2009
2/35
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels
Introduction
■ Design (continued)
2
SIMATIC Mobile Panel 277 (F) IWLAN
• WLAN communication in accordance with IEEE 802.11 a (b/g)
and support of PROFINET
• Two versions as pure W-LAN HMI device without backup function (Mobile Panel 277 IWLAN) and two versions and fail-safe
PROFIsafe device with emergency stop button and
acknowledgement button (Mobile Panel 277F IWLAN)
• Powerful batteries and flexible concept for changing permit
battery replacement "on the fly" without interrupting operation
due to integrated backup battery
• Limited effective range (Mobile Panel 277F IWLAN) and local
identification of the device (Mobile Panel 277F IWLAN) by using transponder technology, comparable with connection
point recognition with cabled Mobile Panels
• Optional variants with: Handwheel, key switch and illuminated
pushbutton
• Fail-safe control elements of the SIMATIC Mobile Panel
277F IWLAN using PROFIsafe:
- Two three-stage acknowledgement buttons
- Emergency stop button
Mobile operation and monitoring in industrial wireless LAN
The SIMATIC Mobile Panel 277(F) IWLAN enables integration as
a WLAN client in wireless LAN networks. This makes it possible
to implement a full-fledged mobile HMI device, which can also
perform tasks that are not possible with stationary or cabled
devices.
Reliable and rugged WLAN networks can be created using
SCALANCE W IWLAN access points. The configuration and
simulation software SINEMA E permits reliable WLAN planning
ahead of time.
The device is configured – just like the cabled Mobile Panels –
with WinCC flexible. The compatibility and continuity permit easy
and problem-free migration of existing projects to the wireless
device.
Transponders have been developed especially for the Mobile
Panel 277(F) IWLAN and can be used for the local identification
of the Mobile Panel in the plant. Comparable with the connection
point recognition (Box-ID) for cabled Mobile Panels, these
transponders can be used to configure location-dependent
functions, e.g. the automatic switchover to a different display
when a certain zone is accessed, or releasing/blocking of functions from the control zone. On the fail-safe Mobile Panel with
enable button and emergency stop button (Mobile Panel 277F
IWLAN), the transponders perform another task: The safetyrelated release of the enable button for hazardous operations.
Full safety function – even wireless!
The SIMATIC Mobile Panel 277F IWLAN is integrated via
PROFINET and PROFIsafe into the safety-oriented program
(Distributed Safety) of a SIMATIC F-CPU. Incorporating and
removing Mobile Panels is possible during runtime. Both of the
safety-related functions "enable button" and "emergency stop
button" comply with SIL 3 in accordance with IEC 61508 or
Category 4 in accordance with EN 954-1 and PLe/Cat. 4 in
accordance with EN ISO 13849-1 and are certified by BGIA and
TÜV. A detailed safety manual is delivered with the Mobile
Panel 277F IWLAN, along with a CD containing the required F
function blocks for integration in the F-program. The F-FBs are
tested and certified - this enables a problem-free and simple
integration of the Mobile Panel.
2/36
Siemens ST 80 · 2009
The emergency stop button is immediately available WLANwide as soon as the Mobile Panel 277F IWLAN is booted up and
the PROFISAFE connection is established with the F-CPU via
IWLAN. To use the enable button locally, transponders must be
installed in the intended control stations. This allows the Mobile
Panel to register for safety-related operation.
Configuration of the transponder and the effective range is also
handled comfortably with WinCC flexible. After configuration
and commissioning, the effective range in the system is approved to ensure the consistency of the planning and configuration. The effect that the emergency stop button and the enable
button should have and which response to certain events (e.g.
leaving the WLAN range) they should have is defined by configuration the F-FBs in the F-CPU – taking account of the safety-relevant properties of the machine. If the Mobile Panel is not used
any longer or if the device should be removed, it is to be moved
to a specified location.
The Mobile Panel 277F IWLAN offers extensive diagnostic and
status information (e.g. concerning the battery charge status,
WLAN functionality, and quality of the effective range) and thus
provides the user – if necessary, supported by the integrated
vibration alarm – with full control of the device and system
operation at all times.
System components for wireless Mobile Panels
Besides the four device versions, the following system
components are offered (to be ordered individually):
For charging the battery in the Mobile Panel (which can be
replaced without tools), either
• the table-top power supply 6AV6 671-5CN00-0AX1 (incl.
power cable for EU, US, UK, JP) is required (only suitable for
operation under laboratory/office conditions) or
• the charger 6AV6 671-5CE00-0AX0, which enables safe
charging of the device (incl. lock for securing the device in the
charger) and can load up to two additional batteries in parallel
(IP65)
For quick and interruption-free battery replacement during
operation
• Additional battery 6AV6 671-5CL00-0AX0 with LED indicator
for charge status indication
To create zones (optional for all versions) and mandatory for
using the enable button in the effective ranges with Mobile Panel
277F IWLAN:
• Transponder 6AV6 671-5CM00-0AX0 (incl. batteries for selfsufficient operation over several years, no cabling is required
on the transponder).
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Overview
■ Function
• Input/output fields
for displaying and changing process values
• Function keys
for direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on function keys.
The function keys can also be used as PROFIBUS DP input
peripherals or directly as PROFINET IO.
The function keys can also be reconfigured as system keys.
A frequently used function such as "Acknowledge alarm" can
thus be applied to a function key.
• Additional command components
such as handwheel, keyswitch and illuminated pushbutton
can be connected to a variable or as a direct control over
PROFIBUS DP input peripherals (DP direct keys) or
PROFINET IO (direct keys).
• Buttons
for direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on buttons.
• Graphics
can be used as symbols instead of text to "label" function keys
or buttons. They can also be used as background displays
(wallpaper).
In the configuration software, a comprehensive library is
available containing graphics and a wide variety of objects. All
editors with an OLE interface can be used as graphics editors
(such as PaintShop, Designer or CorelDraw).
• Vector graphics;
simple geometric basic forms (e.g. lines, circles and
rectangles) can be created direct in the configuring software
• Text fields
for labeling function keys, process images and process
values in any character size
• Curve displays and bars
are used for the display of dynamic values in graphics-based
format
• Display selection from the controller
permits operator prompting from the controller
• Language selection;
5 online languages, 32 configuration languages incl. Asian
and Cyrillic character sets
• Language-dependent texts and graphics
• User administration (security)
- User-oriented access protection according to requirements
of specific sectors
- Authentication with user ID and password
- User-group-specific rights
• Signaling system
- Discrete alarms and analog alarms (limit value messages)
as well as the ALARM_S message frame procedure for
SIMATIC S7 and SIMOTION
- Freely definable message classes (e.g., status/fault
messages) for definition of acknowledgment response and
display of message events
• Message buffer
- Non-volatile, maintenance-free and battery-free message
buffer. The messages are retained even when the Mobile
Panel is disconnected
Siemens ST 80 · 2009
2/37
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Function (continued)
2
• Recipe management
- With additional data storage (on optional multi-media card)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Help texts
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Indicator light
for machine and plant status indication
• Scheduler
for cyclic function execution
• Dynamic positioning of objects and dynamic showing/hiding
of objects
• Permanent window and template concept
- Creation of screen templates:
• Simple maintenance and configuration thanks to:
- Backup and restoration of the project, operating system,
recipe data records and firmware on the optional standard
multi-media card
- Backup and restoration of configuration, operating system,
recipe data sets and firmware on a PC using ProSave
- Project transfer/return over MPI/PROFIBUS DP/serial or
PROFINET
- Automatic transfer identification
- Individual contrast settings
- Project simulation directly on the configuration computer
• WinCC flexible options
- [email protected] for remote operator control and monitoring of
SIMATIC HMI systems based on TCP/IP networks
- [email protected] for communication between HMI systems
based on TCP/IP networks. Remote access to recipe data
sets, passwords and information specific to the HMI system,
and much more.
• Migration
- Any existing Mobile Panel 170 junction boxes can be used in
conjunction with the Mobile Panel 177 because they are fully
compatible. The new function of connection-point detection
can only be used in conjunction with a Mobile Panel 177 with
a DP or PN junction box.
- Projects created for the Mobile Panel 170 using ProTool can
be used again easily in WinCC flexible.
Configuring
Configuration is carried out with the SIMATIC WinCC flexible
Compact, Standard or Advanced engineering software (see
SIMATIC WinCC flexible HMI software/engineering software).
SIMATIC WinCC flexible is the logical further development of the
field-proven ProTool family. Projects generated using ProTool
can be easily migrated to WinCC. If WinCC flexible is started
directly from SIMATIC Manager, data in STEP 7 can be accessed
directly when the panel is configured. Duplicated data input and
data management is, therefore, avoided.
2/38
Siemens ST 80 · 2009
■ Integration
In the case of the Mobile Panel 177 DP, communication with the
PLC can be implemented via PROFIBUS DP at up to 12 Mbit/s,
via MPI or via the serial interface. The necessary interfaces are
already onboard. A variety of drivers – even for PLCs from other
suppliers – are supplied as standard.
In the case of the Mobile Panel 177 PN, communication with the
PLC can be implemented via PROFINET at up to 100 Mbit/s. The
necessary interfaces are already onboard. These are supplied
with the device.
Using the DP interface boxes the Mobile Panel 177 DP can be
connected to:
• SIMATIC S7-200/-300/-400
• SIMATIC WinAC Software/Slot PLC
• SIMOTION
• SIMATIC S5
• SIMATIC 505
• PLCs from other manufacturers
- Allen Bradley
- Mitsubishi
- Modicon Modbus
- GE-Fanuc
- LG GLOFA GM
- OMRON
- Telemechanique Uni-Telway
• SINUMERIK
(optionally with "SINUMERIK HMI copy licence WinCC flexible
CE"; "SINUMERIK HMI engineering package WinCC flexible"
is additionally required for configuring;
For further details, see Catalog NC 60)
Using the DP junctions boxes the Mobile Panel 177 PN can be
connected to:
• SIMATIC S7-200/-300/-400
• WinAC Software
• SIMOTION
Note:
The unwanted operation of a Mobile Panel 177 DP (PROFIBUS)
on a PN (PROFINET) junction box and vice versa is not possible
and is mechanically blocked. Further information can be found
under "System interfaces".
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications
SIMATIC Mobile Panel 177 DP
(MPI/RPOFIBUS)
with integrated enabling button
with integrated enabling button
and STOP pushbutton
with integrated enabling button,
STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
via connection box
via connection box
via connection box
maximum buffer time 10 min
maximum buffer time 10 min
maximum buffer time 10 min
• Type
Flash / RAM
Flash / RAM
Flash / RAM
• Memory usable for
project data/Options
2048 KB of usable memory for user 2048 KB of usable memory for user 2048 KB of usable memory for user
data / no user memory for options data / no user memory for options data / no user memory for options
Supply voltage
Supply voltage
Backup battery
Battery operation
Memory
Type of storage
Configuration
Configuration tool
WinCC flexible Compact Version
2005 or higher (to be ordered
separately)
WinCC flexible Compact Version
2005 or higher (to be ordered
separately)
WinCC flexible Compact Version
2005 or higher (to be ordered
separately)
Display
Display type
STN, 256 colors
STN, 256 colors
STN, 256 colors
Size
5.7" (121 mm x 92 mm)
5.7" (121 mm x 92 mm)
5.7" (121 mm x 92 mm)
Resolution (WxH in pixel)
320 x 240
320 x 240
320 x 240
MTBF backlighting (at 25 °C)
about 50,000 hours
about 50,000 hours
about 50,000 hours
DP direct LEDs (LEDs as
S7 output I/O)
F1...F8
F1...F8
F1...F8
DP direct keys (screen buttons
and keys as S7 input I/O )
F1...F14
F1...F14
F1...F14
Expansions to operator
process-communication
Operating mode
Operating options
Keys and Touch
Keys and Touch
Keys and Touch
Function keys, programmable
14 function keys, 8 with LEDs
14 function keys, 8 with LEDs
14 function keys, 8 with LEDs
System keys
none
none
none
Touchscreen
analog, resistive
analog, resistive
analog, resistive
Numeric/alphabetical input
Yes / Yes
Yes / Yes
Yes / Yes
STOP pushbutton
No
2-channel, enforced latching
2-channel, enforced latching
(can be looped into the emergency (can be looped into the emergency
stop circuit)
stop circuit)
Acknowledgement button
2-channel, number of positions: 3
2-channel, number of positions: 3
2-channel, number of positions: 3
Key-opeated switch
No
No
Yes, 3 switch settings
illuminated pushbutton
No
No
Yes
Handwheel
No
No
Yes
Yes
Yes
Yes
Certifications
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
• Safety category according to
EN954-1
Safety category according
to EN954-1 (enabling button,
STOP button if present) 3
Safety category according
to EN954-1 (enabling button,
STOP button if present) 3
Safety category according
to EN954-1 (enabling button,
STOP button if present) 3
max. relative humidity (in %)
80%
80%
80%
Drop height
1.5 m
1.5 m
1.5 m
Degree of protection
IP65 housing
Certifications & Standards
Ambient conditions
Temperature
• Operation
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
LED colors
Green
Green
Green
Acoustics
No
No
No
Siemens ST 80 · 2009
2/39
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
SIMATIC Mobile Panel 177 DP
(MPI/RPOFIBUS)
2
with integrated enabling button
with integrated enabling button
and STOP pushbutton
with integrated enabling button,
STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
Interfaces
1 x RS422, 1 x RS485
(max. 12 Mbit/s)
1 x RS422, 1 x RS485
(max. 12 Mbit/s)
1 x RS422, 1 x RS485
(max. 12 Mbit/s)
PC card slot
No
No
No
CF card slot
No
No
No
Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
USB
No
No
No
Ethernet
No
No
No
Windows CE
Windows CE
Windows CE
RISC 32-bit, 200 MHz
RISC 32-bit, 200 MHz
RISC 32-bit, 200 MHz
Interfaces
Operating systems
Operating system
Processor
Processor
Functionality under
WinCC flexible
Applications/options
None
None
None
Number of Visual Basic scripts
Not possible
Not possible
Not possible
Task planner
Yes
Yes
Yes
Help system
Yes
Yes
Yes
Status/control
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
Message system
• Number of messages
2 000
2 000
2 000
• Bit messages
Yes
Yes
Yes
• Analog messages
Yes
Yes
Yes
• Message buffer
Ring buffer (n x 256 entries),
retentive, maintenance-free
Ring buffer (n x 256 entries),
retentive, maintenance-free
Ring buffer (n x 256 entries),
retentive, maintenance-free
Recipes
• Recipes
100
100
100
• Data records per recipe
200
200
200
• Entries per data record
200
200
200
• Recipe memory
32 KB integrated Flash,
expandable
32 KB integrated Flash,
expandable
32 KB integrated Flash,
expandable
Number of process images
• Process images
500
500
500
• Variables
1 024
1 024
1 024
• Limit values
Yes
Yes
Yes
• Multiplexing
Yes
Yes
Yes
• Text objects
2,500 text elements
2,500 text elements
2,500 text elements
• Graphics object
Bit maps, vector graphics
Bit maps, vector graphics
Bit maps, vector graphics
• dynamic objects
Diagrams, bar graphs, sliders,
invisible buttons
Diagrams, bar graphs, sliders,
invisible buttons
Diagrams, bar graphs, sliders,
invisible buttons
Image elements
Lists
• Text lists
300
300
300
• Graphics list
100
100
100
• Libraries
Yes
Yes
Yes
Security
• Number of user groups
50
50
50
• Passwords exportable
Yes
Yes
Yes
• Number of user rights
32
32
32
2/40
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
SIMATIC Mobile Panel 177 DP
(MPI/RPOFIBUS)
with integrated enabling button
with integrated enabling button
and STOP pushbutton
with integrated enabling button,
STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
Functionality under
WinCC flexible
(continued)
Data medium support
• PC card
No
No
No
• CF card
No
No
No
• Multi Media Card
Yes
Yes
Yes
• Recording/Printing
-
-
-
• Printer driver
-
-
-
US American (English)
US American (English)
US American (English)
Recording
Fonts
• Keyboard fonts
Languages
• Online languages
5
5
5
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S, CZ /
SK, TR, H
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S, CZ /
SK, TR, H
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S, CZ /
SK, TR, H
• Fonts
Tahoma, WinCC flexible Standard,
symbol languages, all freely scalable
Tahoma, WinCC flexible Standard,
symbol languages, all freely scalable
Tahoma, WinCC flexible Standard,
symbol languages, all freely scalable
MPI/PROFIBUS DP, serial, automatic transfer recognition
MPI/PROFIBUS DP, serial, automatic transfer recognition
MPI/PROFIBUS DP, serial, automatic transfer recognition
S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION,
Allen Bradley (DF1), Allen Bradley
(DF485), Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon (Modbus), other non-Siemens drivers,
See section "System Links"
S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION,
Allen Bradley (DF1), Allen Bradley
(DF485), Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon (Modbus), other non-Siemens drivers,
See section "System Links"
S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION,
Allen Bradley (DF1), Allen Bradley
(DF485), Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon (Modbus), other non-Siemens drivers,
See section "System Links"
Yes
Yes
Yes
Plastic
Plastic
Plastic
245 mm / 58 mm
245 mm / 58 mm
245 mm / 58 mm
1.3 kg
1.3 kg
1.3 kg
Transfer (Upload/Download)
• Transfer of configuration
Process coupling
• Connection to controller
Expandability/openness
• Open Platform Program
Mechanics
Type of housing (front)
Dimensions
Housing diameter/depth (mm)
Weights
Weight
Siemens ST 80 · 2009
2/41
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications
SIMATIC Mobile Panel 177 PN
(PROFINET)
2
with integrated enabling button
with integrated enabling button
and STOP pushbutton
with integrated enabling button,
STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
via connection box
via connection box
via connection box
maximum buffer time 10 min
maximum buffer time 10 min
maximum buffer time 10 min
• Type
Flash / RAM
Flash / RAM
Flash / RAM
• Memory usable for project data/Options
2048 KB of usable memory for user 2048 KB of usable memory for user 2048 KB of usable memory for user
data / no user memory for options data / no user memory for options data / no user memory for options
Supply voltage
Supply voltage
Backup battery
Battery op.
Memory
Type of storage
Configuration
Configuration tool
WinCC flexible Compact Version
2005 or higher (to be ordered
separately)
WinCC flexible Compact Version
2005 or higher (to be ordered
separately)
WinCC flexible Compact Version
2005 or higher (to be ordered
separately)
Display
Display type
STN, 256 colors
STN, 256 colors
STN, 256 colors
Size
5.7" (121 mm x 92 mm)
5.7" (121 mm x 92 mm)
5.7" (121 mm x 92 mm)
Resolution (WxH in pixel)
320 x 240
320 x 240
320 x 240
MTBF backlighting (at 25 °C)
about 50,000 hours
about 50,000 hours
about 50,000 hours
DP direct LEDs (LEDs as S7
output I/O)
F1...F8
F1...F8
F1...F8
DP direct keys (screen buttons
and keys as S7 input I/O )
F1...F14
F1...F14
F1...F14
Expansions to operator processcommunication
Operating mode
Operating options
Keys and Touch
Keys and Touch
Keys and Touch
Function keys, programmable
14 function keys, 8 with LEDs
14 function keys, 8 with LEDs
14 function keys, 8 with LEDs
System keys
0
0
0
Touchscreen
analog, resistive
analog, resistive
analog, resistive
Numeric/alphabetical input
Yes / Yes
Yes / Yes
Yes / Yes
STOP pushbutton
No
2-channel, enforced latching
2-channel, enforced latching
(can be looped into the emergency (can be looped into the emergency
stop circuit)
stop circuit)
Acknowledgement button
2-channel, number of positions: 3
2-channel, number of positions: 3
2-channel, number of positions: 3
Key-opeated switch
No
No
Yes, 3 switch settings
illuminated pushbutton
No
No
Yes
Handwheel
No
No
Yes
Yes
Yes
Yes
Certifications
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
• Safety category according to
EN954-1
Safety category according to
EN954-1 (enabling button,
STOP button if present) 3
Safety category according to
EN954-1 (enabling button,
STOP button if present) 3
Safety category according to
EN954-1 (enabling button,
STOP button if present) 3
max. relative humidity (in %)
80%
80%
80%
Drop height
1.5 m
1.5 m
1.5 m
• Operation
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Degree of protection
IP65 housing
Certifications & Standards
Ambient conditions
Temperature
2/42
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
SIMATIC Mobile Panel 177 PN
(PROFINET)
with integrated enabling button
with integrated enabling button
and STOP pushbutton
with integrated enabling button,
STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
I/O devices
Printer
Printer
Printer
LED colors
Green
Green
Green
Acoustics
No
No
No
I/O Options
Interfaces
Interfaces
1 x RS485, 1 x Ethernet (RJ45)
1 x RS485, 1 x Ethernet (RJ45)
1 x RS485, 1 x Ethernet (RJ45)
PC card slot
No
No
No
CF card slot
No
No
No
Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
USB
No
No
No
Windows CE
Windows CE
Windows CE
RISC 32-bit, 200 MHz
RISC 32-bit, 200 MHz
RISC 32-bit, 200 MHz
Operating systems
Operating system
Processor
Processor
Functionality under
WinCC flexible
Applications/options
[email protected], [email protected]
[email protected], [email protected]
[email protected], [email protected]
Number of Visual Basic scripts
Not possible
Not possible
Not possible
Task planner
Yes
Yes
Yes
Help system
Yes
Yes
Yes
Status/control
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
Message system
• Number of messages
2 000
2 000
2 000
• Bit messages
Yes
Yes
Yes
• Analog messages
Yes
Yes
Yes
• Message buffer
Ring buffer (n x 256 entries),
retentive, maintenance-free
Ring buffer (n x 256 entries),
retentive, maintenance-free
Ring buffer (n x 256 entries),
retentive, maintenance-free
Recipes
• Recipes
100
100
100
• Data records per recipe
200
200
200
• Entries per data record
200
200
200
• Recipe memory
32 KB integrated Flash,
expandable
32 KB integrated Flash,
expandable
32 KB integrated Flash,
expandable
Number of process images
• Process images
500
500
500
• Variables
1 024
1 024
1 024
• Limit values
Yes
Yes
Yes
• Multiplexing
Yes
Yes
Yes
Image elements
• Text objects
2,500 text elements
2,500 text elements
2,500 text elements
• Graphics object
Bit maps, vector graphics
Bit maps, vector graphics
Bit maps, vector graphics
• dynamic objects
Diagrams, bar graphs, sliders,
invisible buttons
Diagrams, bar graphs, sliders,
invisible buttons
Diagrams, bar graphs, sliders,
invisible buttons
• Text lists
300
300
300
• Graphics list
100
100
100
• Libraries
Yes
Yes
Yes
Lists
Siemens ST 80 · 2009
2/43
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
SIMATIC Mobile Panel 177 PN
(PROFINET)
2
with integrated enabling button
with integrated enabling button
and STOP pushbutton
with integrated enabling button,
STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
Functionality under
WinCC flexible
(continued)
Security
• Number of user groups
50
50
50
• Passwords exportable
Yes
Yes
Yes
• Number of user rights
32
32
32
Data medium support
• PC card
No
No
No
• CF card
No
No
No
• Multi Media Card
Yes
Yes
Yes
• Recording/Printing
-
-
-
• Printer driver
-
-
-
US American (English)
US American (English)
US American (English)
Recording
Fonts
• Keyboard fonts
Languages
• Online languages
5
5
5
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
Tahoma, WinCC flexible Standard,
symbol languages, all freely
scalable
Tahoma, WinCC flexible Standard,
symbol languages, all freely
scalable
Tahoma, WinCC flexible Standard,
symbol languages, all freely
scalable
serial, Ethernet, automatic transfer
recognition
serial, Ethernet, automatic transfer
recognition
serial, Ethernet, automatic transfer
recognition
S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION See section
"System Links"
S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION See section
"System Links"
S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION See section
"System Links"
Yes
Yes
Yes
Plastic
Plastic
Plastic
245 mm / 58 mm
245 mm / 58 mm
245 mm / 58 mm
1.3 kg
1.3 kg
1.3 kg
Transfer (Upload/Download)
• Transfer of configuration
Process coupling
• Connection to controller
Expandability/openness
• Open Platform Program
Mechanics
Type of housing (front)
Dimensions
Housing diameter/depth (mm)
Weights
Weight
2/44
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Ordering data
Order No.
SIMATIC Mobile Panel 177 DP
(MPI/PROFIBUS)1)
F
6AV6 645-0AA01-0AX0
• With integr. enabling button
and STOP pushbutton
F
6AV6 645-0AB01-0AX0
• With integr. acknowledgement
button, STOP button, handwheel, key-operated switch
and illuminated pushbutton
F
6AV6 645-0AC01-0AX0
F
Documentation (to be ordered separately)
• German
6AV6 691-1AB01-3AA0
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
6AV6 645-0BA01-0AX0
• Spanish
6AV6 691-1AB01-3AE0
WinCC flexible Communication
User Manual
• With integr. enabling button
and STOP pushbutton
F
6AV6 645-0BB01-0AX0
• With integr. acknowledgement
button, STOP button, handwheel, key-operated switch
and illuminated pushbutton
F
6AV6 645-0BC01-0AX0
Mobile Panel 177 PN
Plus starter kit
F
6AV6 651-5DA01-0AA0
• Mobile Panel 177 PN with integrated enabling button, STOP
pushbutton, handwheel, key-operated switch and illuminated
pushbutton
2
User Manual WinCC flexible
Compact/Standard/Advanced
• English
SIMATIC Mobile Panel 177 PN
(PROFINET)1)
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
• PN Plus connection box
• PN connecting cable, 10 m
• Wall holder
• SIMATIC WinCC flexible
Compact
System components for Mobile Panels
DP junction box for
Mobile Panels (MPI/PROFIBUS)
• SIMATIC HMI Manual Collection
(DVD), 5 languages (English,
French, German, Italian,
Spanish)
• Basic
• Plus
• Software Update Service
for 1 year
Mobile Panel 177 DP
Plus starter kit
see HMI Software
with SIMATIC WinCC flexible
• With integr. enabling button
• With integr. enabling button
Order No.
Configuration
F
6AV6 651-5BA01-0AA0
• Mobile Panel 177 DP with integrated enabling button, STOP
pushbutton, handwheel, keyoperated switch and illuminated
pushbutton
6AV6 671-5AE00-0AX0
A
6AV6 671-5AE10-0AX0
• Basic
A
6AV6 671-5AE01-0AX0
• Plus
A
6AV6 671-5AE11-0AX0
PN junction box for Mobile
Panel (PROFINET)
DP connecting cable
(MPI/PROFIBUS)
Standard cables
• DP Plus junction box
•2m
6XV1 440-4AH20
• DP connecting cable, 10 m
•5m
6XV1 440-4AH50
• Wall holder
• 10 m
6XV1 440-4AN10
• SIMATIC WinCC flexible
Compact
• 15 m
6XV1 440-4AN15
• 25 m
6XV1 440-4AN25
• SIMATIC HMI Manual Collection
(CD), 5 languages (English,
French, German, Italian,
Spanish)
• Software Update Service
for 1 year
Intermediate lengths2)
•8m
6XV1 440-4AH80
• 20 m
6XV1 440-4AN20
A) Subject to export regulations: AL: N and ECCN: EAR99H
B) Subject to export regulations: AL: N and ECCN: EAR99S
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
1)
The system components (connecting cables and connection boxes) must
be ordered separately.
2)
Delivery time approximately 6 weeks
Siemens ST 80 · 2009
2/45
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Ordering data
Additional information is available in the Internet under:
PN connecting cable
(PROFINET)
http://www.siemens.com/mobile-panels
Standard cables
•2m
6XV1 440-4BH20
•5m
6XV1 440-4BH50
•8m
6XV1 440-4BH80
• 10 m
6XV1 440-4BN10
• 15 m
6XV1 440-4BN15
• 20 m
6XV1 440-4BN20
• 25 m
6XV1 440-4BN25
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
Accessories
Accessories for Mobile Panels
see HMI accessories,
from page 2/158
■ Dimensions
All specifications in mm.
123,9
7,80
61,3
Mobile Panel 177 – front and side view
2/46
Siemens ST 80 · 2009
G_ST80_XX_00046
245
121,7
92,3
2
■ More information
Order No.
System components for Mobile Panels
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Overview
■ Function
• Input/output fields
for displaying and changing process values
• Function keys
for direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on function keys.
The function keys can also be used as PROFIBUS DP input
peripherals or directly as PROFINET IO. The function keys can
also be reconfigured as system keys. A frequently used
function such as "Acknowledge alarm" can thus be applied to
a function key. No function keys are available on the Mobile
Panel 277 10".
• Additional command components
such as handwheel, keyswitch and illuminated pushbutton
can be connected to a variable or as a direct control over
PROFIBUS DP input peripherals (DP direct keys) or
PROFINET IO (direct keys).
No additional operator controls are available on the Mobile
Panel 277 10".
• Buttons
are used for direct triggering of functions and actions. Up to
16 functions can be configured simultaneously on buttons.
• Graphics
can be used as symbols instead of text to "label" function keys
or buttons. They can also be used as full-screen background
images.
In the configuration software, a comprehensive library is
available containing graphics and a wide variety of objects. All
editors with an OLE interface can be used as graphics editors
(such as PaintShop, Designer or CorelDraw).
• Vector graphics;
simple geometric basic forms (e.g. lines, circles and
rectangles) can be created direct in the configuration software
• Text fields
for labeling function keys, process images and process
values in any character size
• Curve displays and bars
are used for the display of dynamic values in graphics-based
format
• Display selection from the controller
permits operator prompting from the controller
• Presentation of HTML documents with MS Pocket Internet
Explorer
• Visual Basic Script, flexibility thanks to the implementation of
new functions including linking to variables (comparison
operations, loops, etc.)
• Language switching
16 online languages, 32 configuration languages incl. Asiatic
and Cyrillic character sets
- Language-dependent texts and graphics
• User administration (security)
- User-oriented access protection according to requirements
of specific sectors
- Authentication with user ID and password
- User-group-specific rights
• Signaling system
- Discrete alarms and analog alarms (limit value messages)
as well as the ALARM_S message frame procedure for
SIMATIC S7 and SIMOTION
- Freely definable message classes (e.g., status/fault messages) for definition of acknowledgment response and
display of message events
• Message buffer
- Non-volatile, maintenance-free and battery-free message
buffer. The messages are retained even when the Mobile
Panel is disconnected
Siemens ST 80 · 2009
2/47
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Function (continued)
2
• Recipe management
- With additional data storage (on optional multi-media card)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Help texts
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Indicator light
for machine and plant status indication
• Scheduler
for cyclic function execution
• Dynamic positioning of objects and dynamic showing/hiding
of objects
• Permanent window and template concept
- Creation of screen templates:
• Simple maintenance and configuration thanks to:
- Backup and restoration of the project, operating system,
recipe data records and firmware on the optional standard
multi-media card
- Backup and restoration of configuration, operating system,
recipe data sets and firmware on a PC using ProSave
- Project transfer/return over MPI/PROFIBUS DP/serial or
PROFINET
- Automatic transfer identification
- Individual contrast settings
- Project simulation directly on the configuration computer
• WinCC flexible options
- [email protected] for remote operator control and monitoring of
SIMATIC HMI systems based on TCP/IP networks
- [email protected] for communication between HMI systems
based on TCP/IP networks. Remote access to recipe data
sets, passwords and information specific to the HMI system,
and much more.
- OPC server Communication with applications (e.g. MES,
ERP, or applications in the office sector) from various
manufacturers (see HMI Software/runtime software
SIMATIC WinCC flexible /WinCC flexible RT options)
- Audit
Configuration
Configuration is carried out with the SIMATIC WinCC flexible
Compact, Standard or Advanced engineering software (see
SIMATIC WinCC flexible HMI Software/engineering software).
SIMATIC WinCC flexible is the logical further development of the
field-proven ProTool family. Projects generated using ProTool
can be easily migrated to WinCC. If WinCC flexible is started
directly from SIMATIC Manager, data in STEP 7 can be accessed
directly when the panel is configured. Double data entry and
data storage are prevented this way.
2/48
Siemens ST 80 · 2009
■ Integration
The SIMATIC Mobile Panel 277 is generally provided for optional
PROFIBUS or PROFINET communication. No distinction is made
at device level.
This means the device can either be operated
• for the communication via MPI/PROFIBUS with the DP
cables and connection to the DP "Basic" or "Plus"
connection boxes or
• for the communication via PROFINET with the PN cables
and connection to the PN "Basic" or "Plus" connection
boxes
.A variety of drivers – even for PLCs from other suppliers – are
supplied as standard.
Using the DP connection boxes, the Mobile Panel 277 DP can be
connected to:
• SIMATIC S7-200/-300/-400
• SIMATIC WinAC Software/Slot PLC
• SIMOTION
• SIMATIC S5
• SIMATIC 505
• PLCs from other manufacturers
- Allen Bradley
- Mitsubishi
- Modicon Modbus
- GE-Fanuc
- LG GLOFA GM
- OMRON
• SINUMERIK
(optionally with "SINUMERIK HMI copy licence WinCC flexible
CE"; "SINUMERIK HMI engineering package WinCC flexible"
is additionally required for configuring; For further details, see
Catalog NC 60)
Using the PN connection boxes, the Mobile Panel 277 can be
connected to:
• SIMATIC S7-200/-300/-400
• WinAC Software
• SIMOTION
• Over Ethernet (TCP/IP) to a higher-level PC, network printer
Note:
Further information can be found under "System interfaces".
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Technical specifications
SIMATIC Mobile Panel 277
8"
with integrated
enabling button
8"
with integrated enabling
button and STOP pushbutton
8"
with integrated enabling
button, STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
10"
with integrated enabling
button and STOP pushbutton
via connection box
via connection box
via connection box
Supply voltage
Supply voltage
via connection box
Backup battery
Battery operation
maximum buffer time 10 min
Memory
Type
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Memory usable for project data
6 MB
6 MB
6 MB
6 MB
Time
Clock
• Type
Hardware clock, battery backup, synchronizable
Protocols
PROFINET
Yes
Yes
Yes
Yes
PROFINET IO
Yes
Yes
Yes
Yes
WinCC flexible Standard
Version 2005 SP1 or
higher (to be ordered
separately)
WinCC flexible Standard
Version 2005 SP1 or
higher (to be ordered
separately)
WinCC flexible Standard
Version 2005 SP1 or
higher (to be ordered
separately)
WinCC flexible Standard
Version 2008 or higher
(to be ordered separately)
Display type
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
Size
7.5"
7.5"
7.5"
10.4"
Resolution (WxH in pixel)
640 x 480
640 x 480
640 x 480
800 x 600
MTBF backlighting (at 25 °C)
about 50 000 h
about 50 000 h
about 50 000 h
about 50 000 h
DP direct LEDs
(LEDs as S7 output I/O)
F1...F18
F1...F18
F1...F18
-
DP direct keys (screen buttons
and keys as S7 input I/O )
F1...F18, Number of bytes F1...F18, Number of bytes F1...F18, Number of bytes for configurable buttons: for configurable buttons: for configurable buttons:
10
10
10
Configuration
Configuration tool
Display
Expansions to operator process
communication
Operating mode
Operating options
Keys and Touch
Keys and Touch
Keys and Touch
Touch
Function keys, programmable
18 function keys, 18 with
LEDs
18 function keys, 18 with
LEDs
18 function keys, 18 with
LEDs
None
Touchscreen
analog, resistive
analog, resistive
analog, resistive
analog, resistive
Numeric/alphabetical input
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Connection for mouse/keyboard/barcode reader
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
STOP pushbutton
No
2-channel, enforced latching (can be looped into the emergency stop circuit)
Acknowledgement button
2-channel, number of positions: 3
Key-opeated switch
No
No
Yes, 3 switch settings
No
illuminated pushbutton
No
No
Yes; Two illuminated
pushbuttons
No
Handwheel
No
No
Yes
No
max. relative humidity (in %)
80%
80%
80%
90%
Drop height
1.2 m
1.2 m
1.2 m
1m
• Operation
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Ambient conditions
Temperature
Siemens ST 80 · 2009
2/49
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Technical specifications (continued)
SIMATIC Mobile Panel 277
8"
with integrated
enabling button
8"
with integrated enabling
button and STOP pushbutton
8"
with integrated enabling
button, STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
10"
with integrated enabling
button and STOP pushbutton
Yes
Yes
Yes
Yes
Certifications
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
• Safety category according
to EN954-1
Safety category according
to EN954-1 (enabling
button, STOP button if
present) 3
Safety category according
to EN954-1 (enabling
button, STOP button if
present) 3
Safety category according
to EN954-1 (enabling
button, STOP button if
present) 3
Safety category according
to EN954-1 (enabling
button, STOP button if
present) 3
I/O devices
Printer, barcode reader
Printer, barcode reader
Printer, barcode reader
Printer, barcode reader
LED colors
Green
Green
Green
-
Interfaces
1 x RS422, 1 x RS485
(max. 12 Mbit/s),
1 x Ethernet (RJ45)
1 x RS422, 1 x RS485,
(max. 12 Mbit/s),
1 x Ethernet (RJ45)
1 x RS422, 1 x RS485,
(max. 12 Mbit/s),
1 x Ethernet (RJ45)
1 x RS422, 1 x RS485
(max. 12 Mbit/s),
1 x Ethernet (RJ45)
Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
USB
1 x USB
1 x USB
1 x USB
1 x USB
Windows CE
Windows CE
Windows CE
Windows CE
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
ARM
2
Degree of protection
IP65 housing
Certifications & Standards
I/O devices
Interfaces
Operating systems
Operating system
Processor
Processor
Functionality under
WinCC flexible
Applications/options
Internet Explorer, [email protected], [email protected]
Number of Visual Basic scripts
50
50
50
50
Task planner
Yes
Yes
Yes
Yes
Help system
Yes
Yes
Yes
Yes
Status/control
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
Message system
• Number of messages
4 000
4 000
4 000
4 000
• Bit messages
Yes
Yes
Yes
Yes
• Analog messages
Yes
Yes
Yes
Yes
• Message buffer
Ring buffer (n x 512
entries), retentive,
maintenance-free
Ring buffer (n x 512
entries), retentive,
maintenance-free
Ring buffer (n x 512
entries), retentive,
maintenance-free
Ring buffer (n x 512
entries), retentive,
maintenance-free
Recipes
• Recipes
300
300
300
300
• Data records per recipe
500
500
500
200
• Entries per data record
1000
1000
1000
1000
• Recipe memory
64 KB integrated Flash,
expandable
64 KB integrated Flash,
expandable
64 KB integrated Flash,
expandable
64 KB integrated Flash,
expandable
Number of process images
• Process images
500
500
500
500
• Variables
2 048
2 048
2 048
2 048
• Limit values
Yes
Yes
Yes
Yes
• Multiplexing
Yes
Yes
Yes
Yes
10 000 text elements
10 000 text elements
10 000 text elements
Image elements
• Text objects
10 000 text elements
• Graphics object
Bit maps, icons, vector graphics
• Dynamic objects
Diagrams, bar graphs, sliders, analog display, invisible buttons
2/50
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Technical specifications (continued)
SIMATIC Mobile Panel 277
8"
with integrated
enabling button
8"
with integrated enabling
button and STOP pushbutton
8"
with integrated enabling
button, STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
10"
with integrated enabling
button and STOP pushbutton
Functionality under
WinCC flexible (continued)
Lists
• Text lists
500
500
500
500
• Graphics list
400
400
400
400
• Libraries
Yes
Yes
Yes
Yes
Archiving
• Number of archives per project
20
20
20
20
• Number of measuring points per
project
20
20
20
20
• Number of entries per archive
10 000
10 000
10 000
10 000
• Memory location
Multi Media Card
Multi Media Card
Multi Media Card
Multi Media Card
Security
• Number of user groups
50
50
50
50
• Passwords exportable
Yes
Yes
Yes
Yes
• Number of user rights
32
32
32
32
Yes
Yes
Yes
Yes
Alarms, report
(shift report),
color print, hardcopy
Alarms, report
(shift report),
color print, hardcopy
Alarms, report
(shift report),
color print, hardcopy
16
16
Data medium support
• Multi Media Card
Recording
• Recording/Printing
Fonts
• Keyboard fonts
US American (English)
Languages
• Online languages
16
• Configuration languages
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK, FIN, GR, J, KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
Tahoma, Arial, Courier
New, WinCC flexible Standard, symbol languages,
all freely scalable
Tahoma, Arial, Courier
New, WinCC flexible Standard, symbol languages,
all freely scalable
16
Tahoma, Arial, Courier
New, WinCC flexible Standard, symbol languages,
all freely scalable
Tahoma, Arial, Courier
New, WinCC flexible Standard, symbol languages,
all freely scalable
Transfer (Upload/Download)
• Transfer of configuration
MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition
Process coupling
• Connection to controller
S5, S7-200, S7- 300/400,
TI 505, Win AC, PC
(TCP/IP), SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley
(DF485), Mitsubishi (FX),
OMRON (LINK/Multilink),
Modicon (Modbus),
other non-Siemens
drivers, See "System
Links"
S5, S7-200, S7- 300/400,
TI 505, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley
(DF485), Mitsubishi (FX),
OMRON (LINK/Multilink),
Modicon (Modbus),
other non-Siemens
drivers, See "System
Links"
S5, S7-200, S7- 300/400,
TI 505, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley
(DF485), Mitsubishi (FX),
OMRON (LINK/Multilink),
Modicon (Modbus),
other non-Siemens
drivers, See "System
Links"
S5, S7-200, S7- 300/400,
TI 505, Win AC,
SINUMERIK, SIMOTION,
Allen Bradley (DF1), Allen
Bradley (DF485), Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus), other
non-Siemens drivers,
See "System Links"
Plastic
Plastic
Plastic
Plastic
290 /103
290 /103
290 /103
350 x 320 /103
1.7 kg
1.7 kg
1.7 kg
2.3 kg
Mechanics
Type of housing (front)
Dimensions
Housing diameter/depth (mm)
Weights
Weight
Siemens ST 80 · 2009
2/51
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Ordering data
Order No.
SIMATIC Mobile Panel 277 8"1)
2
Order No.
SIMATIC HMI Manual Collection B
• With integr. enabling button
F
6AV6 645-0CA01-0AX0
• With integr. enabling button
and STOP pushbutton
F
6AV6 645-0CB01-0AX0
• With integr. enabling button,
STOP pushbutton, handwheel,
key-operated switch and
illuminated pushbutton
F
6AV6 645-0CC01-0AX0
• With integr. enabling button and F
STOP pushbutton
6AV6 645-0BE02-0AX0
SIMATIC Mobile Panel 277 10"
6AV6 691-1SA01-0AX0
Electronic documentation, on
DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and communication manuals for SIMATIC
HMI
System components for Mobile Panels
SIMATIC Mobile Panel 277 8"
starter package
DP connection box for Mobile
Panels (MPI/PROFIBUS)
• Basic
• Plus
for:
• DP communication
F
6AV6 651-5EB01-0AA0
• PN communication
F
6AV6 651-5FB01-0AA0
Configuration
with SIMATIC WinCC flexible
see HMI software
Documentation (to be ordered separately)
Operating Instructions for
Mobile Panel 277
• German
6AV6 691-1DL01-0AA0
• English
6AV6 691-1DL01-0AB0
• French
6AV6 691-1DL01-0AC0
• Italian
6AV6 691-1DL01-0AD0
• Spanish
6AV6 691-1DL01-0AE0
User Manual WinCC flexible
Compact/Standard/Advanced
6AV6 671-5AE00-0AX0
A
6AV6 671-5AE10-0AX0
• Basic
A
6AV6 671-5AE01-0AX0
• Plus
A
6AV6 671-5AE11-0AX0
PN connection box for
Mobile Panel (PROFINET)
DP connecting cable (MPI/PROFIBUS)
Standard cables
2m
6XV1 440-4AH20
5m
6XV1 440-4AH50
10 m
6XV1 440-4AN10
15 m
6XV1 440-4AN15
25 m
6XV1 440-4AN25
Intermediate lengths2)
8m
6XV1 440-4AH80
20 m
6XV1 440-4AN20
• German
6AV6 691-1AB01-3AA0
PN connecting cable (PROFINET)
• English
6AV6 691-1AB01-3AB0
Standard cables
• French
6AV6 691-1AB01-3AC0
2m
6XV1 440-4BH20
• Italian
6AV6 691-1AB01-3AD0
5m
6XV1 440-4BH50
• Spanish
6AV6 691-1AB01-3AE0
8m
6XV1 440-4BH80
10 m
6XV1 440-4BN10
15 m
6XV1 440-4BN15
20 m
6XV1 440-4BN20
25 m
6XV1 440-4BN25
WinCC flexible Communication
User Manual
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
A) Subject to export regulations: AL: N and ECCN: EAR99H
B) Subject to export regulations: AL: N and ECCN: EAR99S
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
1)
The system components (connecting cables and connection boxes) must
be ordered separately.
2)
Delivery time approximately 6 weeks
2/52
Siemens ST 80 · 2009
Accessories
Accessories for Mobile Panels
see HMI accessories,
from page 2/158
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Dimensions
■ More information
Additional information is available in the Internet under:
All specifications in mm.
http://www.siemens.com/mobile-panels
8°
2
Note
155 mm
103 mm
129 mm
ø 290 mm
G_ST80_XX_00277
117 mm
9 mm
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
Mobile Panel 277 8" – front and side view
320
8°
350
103
129
G_ST80_XX_00354
159
212
Mobile Panel 277 10" – front and side view
Siemens ST 80 · 2009
2/53
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Overview
2
■ Function
• Input/output fields
for displaying and changing of process values
• Function keys
are used for directly actuating functions and actions. Up to 16
functions can be configured simultaneously on function keys.
The function keys can also be used directly as PROFINET IO.
The function keys can also be reconfigured as system keys. A
function that is used frequently such as "Acknowledge message" can be allocated to a function key this way.
• Auxiliary control elements
such as handwheels, key switches and illuminated pushbuttons can be assigned with a variable or as a direct actuation
via PROFINET IO (direct keys)
• Buttons
are used for directly actuating functions and actions. Up to 16
functions can be configured simultaneously on buttons
• Graphics
can be used as symbols instead of text for "labeling" function
keys or buttons. They can also be used as background
displays (wallpaper).
In the configuration software, a comprehensive library is
available containing graphics and a wide variety of objects. All
editors with an "OLE" interface can be used as graphic editors,
e.g. Paint-Shop, Designer, CorelDraw, etc.
• Vector graphics
Simple geometric basic forms (e.g. lines, circles and
rectangles) can be created directly in the configuration
software
• Text fields
for labeling function keys, process screens and process
values in any font size
• Trend views and bars
are used for the graphic display of dynamic values
• Display selection from the controller
supports operator prompting from the controller
• Presentation of HTML documents with MS Pocket Internet
Explorer
• Visual Basic Script, flexibility thanks to the implementation of
new functions including linking to variables (comparison
operations, loops, etc.)
2/54
Siemens ST 80 · 2009
• Language switching
16 online languages, 32 configuration languages incl. Asiatic
and Cyrillic character sets
- Language-dependent texts and graphics
• User administration (security)
- User-oriented access protection according to requirements
of specific sectors
- Authentication with user name and password
- User-group-specific rights
• Signaling system
- Discrete and analog alarms (edge alarms) as well as the
ALARM_S message frame procedure for SIMATIC S7
- Freely definable message classes (e.g. status/fault messages) for definition of acknowledgment response and display of alarm events
• Message buffer
- Non-volatile, maintenance-free and message buffer without
battery. The messages remain stored when the mobile panel
has the battery removed as well
• Recipe management
- With additional data storage (on optional Multi Media Card)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools Excel and Access
is possible
• Help texts
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Message lamps
for displaying machine and system status
• Task planner
for cyclic function processing
• Dynamic positioning of objects and dynamic showing/hiding
of objects
• Permanent window and template concept
- Creation of screen templates
• Simple maintenance and configuration thanks to:
- Save and restore (Backup/Restore) projects, operating system, recipe data records and firmware to the optional standard Multi Media Card
- Backup and restoration (Backup/Restore) of the configuration, operating system, recipe data records and firmware on
a PC with ProSave
- Project transfer/return transfer via PROFINET/WLAN
- Automatic transfer identification
- Individual brightness setting
- Project simulation directly on the configuration computer
• WinCC flexible options
- [email protected] for remote operation and monitoring of
SIMATIC HMI systems based on TCP/IP networks
- [email protected] for communication between HMI systems
based on TCP/IP networks. Remote access to recipe data
records, passwords and HMI system-specific information
and much more. (Mobile Panel 277F IWLAN as server: View
only)
- OPC server: Communication with applications (e.g. MES,
ERP, or applications in the office sector) from various manufacturers (see HMI software/runtime software SIMATIC
WinCC flexible/WinCC flexible RT options)
- Audit
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Function (continued)
Configuration
Configuration is carried out with the SIMATIC WinCC flexible
Standard or Advanced configuration software (see
SIMATIC WinCC flexible HMI software/engineering software).
SIMATIC WinCC flexible is a consistent further development of
the proven ProTool family. Projects created with ProTool can be
comfortably transferred to WinCC. If WinCC flexible is started
directly from the SIMATIC Manager, the data in STEP 7 can be
accessed directly while configuring the panel. Double data entry
and data storage is prevented this way.
System requirements
SIMATIC Mobile Panel
277 IWLAN
5 GHz freSIMATIC F-CPU
quency band
(Distributed
(IEEE 802.11a) Safety)
Only WLAN
utilization (HMI)
I
–
When using
transponders
!
–
When using
Profinet IO
I
–
!
!
277F IWLAN
(Failsafe)
2
I = Recommended
! = Requirement
– = Not required
The Mobile Panel 277(F) IWLAN can be connected to:
• SIMATIC S7-200/-300/-400 (one F-CPU required for integrating the Mobile Panel 277F IWLAN)
Note:
Further information can be found under "System interfaces".
■ Integration
The SIMATIC Mobile Panel 277(F) IWLAN communicates via the
WLAN Standard IEEE 802.11 a(b/g) via PROFINET. The Mobile
Panel 277F IWLAN devices also support PROFIsafe communication.
IWLAN infrastructure
There are four device versions:
The required IWLAN infrastructure is set up with the IWLAN
Access Points SCALANCE W-780, preferably with the version
SCALANCE W786-2RR, which fully supports all possible applications of the Mobile Panel 277(F) IWLAN.
For operating a plant without fail-safe communication, the
version SCALANCE W786-1PRO can also be used.
For mobile operation and monitoring via WLAN:
• Mobile Panel 277 IWLAN
• Mobile Panel 277 IWLAN with handwheel, key switch and
illuminated pushbuttons
If the radio link of a single Access Point (radio cell) is insufficient,
it can be expanded by further Access Points. The individual
radio links must not overlap to permit that moving stations such
as the Mobile Panel 277(F) IWLAN can be transferred from one
Access Point to the next without interruptions (roaming). This is
performed transparently for the application.
The Access Point provides an Industrial Ethernet interface for
connection to the wired network.
In addition to a reliable radio link, the SCALANCE W-780 Access
Points stand out due to their optimum support of standardized IT
mechanisms:
• IEEE 802.11b/ g/ a/ h for different frequency ranges
• IEEE 802.11e for multimedia, wireless multimedia (WMM)
• IEEE 802.11i for security
• Construction of redundant networks with the Rapid Spanning
Tree Protocol (RSTP)
• Virtual networks (VLAN) to logically separate, for example,
different user groups
• Sending the log entries of the SCALANCE W devices to a
Syslog server
As fail-safe device for safety-oriented operation as well:
• Mobile Panel 277F IWLAN with enable button and emergency
stop button
• Mobile Panel 277F IWLAN with enable button, emergency
stop button, handwheel, key switch and illuminated
pushbuttons
For the versions Mobile Panel 277F IWLAN (PROFIsafe), the
following system prerequisites apply:
• The Mobile Panel must be connected as a safe device
(PROFIsafe, Distributed Safety)
• Use of a SIMATIC F-CPU
Siemens ST 80 · 2009
2/55
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Technical specifications
SIMATIC Mobile Panel
2
277 IWLAN
277(F) IWLAN
Communication via
WLAN (PROFINET)
Communication via
WLAN (PROFINET)
with integrated handwheel, key-operated
switch and two illuminated
pushbuttons
Communication via
WLAN (PROFINET) with
enabling button and
emergency STOP button
Communication via
WLAN (PROFINET)
with enabling button
and emergency STOP
button, handwheel, keyoperated switch and two
illuminated pushbuttons
Supply voltage
Via charging station
Yes
Yes
Yes
Yes
Via table power supply
Yes
Yes
Yes
Yes
Rated voltage
7.2 V
7.2 V
7.2 V
7.2 V
Capacity
5.100 mAh
5.100 mAh
5.100 mAh
5.100 mAh
Number of loading cycles,
min
500
500
500
500
Charging time, typ.
4h
4h
4h
4h
Operating time, typ.
4h
4h
4h
4h
Display for battery capacity Yes
Yes
Yes
Yes
Energy-saving mode
Yes
Yes
Yes
Yes
Battery exchange in operation
Yes
Yes
Yes
Yes
maximum buffer time 5 min
maximum buffer time 5 min
maximum buffer time 5 min
maximum buffer time 5 min
• Type
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
• Memory usable for
project data/Options
6 MByte Usable memory
for user data
6 MByte Usable memory
for user data
6 MByte Usable memory
for user data
6 MByte Usable memory
for user data
Hardware clock, battery
backed, Synchronizable
Hardware clock, battery
backed, Synchronizable
Hardware clock, battery
backed, Synchronizable
Hardware clock, battery
backed, Synchronizable
Backup battery
Battery operation
Memory
Type of storage
Time
Clock
• Type
Protocols
PROFINET
Yes
Yes
Yes
Yes
PROFINET IO
Yes
Yes
Yes
Yes
PROFIsafe
-
-
Yes
Yes
WinCC flexible Standard
version 2007 (must be
ordered separately)
WinCC flexible Standard
version 2007 (must be
ordered separately)
WinCC flexible Standard
version 2007 (must be
ordered separately)
WinCC flexible Standard
version 2007 (must be
ordered separately)
Configuration
Configuration tool
Display
Display type
TFT, 65536 Colors
TFT, 65536 Colors
TFT, 65536 Colors
TFT, 65536 Colors
Size
7.5"
7.5"
7.5"
7.5"
Resolution (WxH in pixel)
640 x 480
640 x 480
640 x 480
640 x 480
MTBF backlighting
(at 25 °C)
Approx. 50000 h
Approx. 50000 h
Approx. 50000 h
Approx. 50000 h
Operating options
Key and Touch
Key and Touch
Key and Touch
Key and Touch
Function keys,
programmable
18 Function keys,
18 With LEDs
18 Function keys,
18 With LEDs
18 Function keys,
18 With LEDs
18 Function keys,
18 With LEDs
Touchscreen
analog, resistive
analog, resistive
analog, resistive
analog, resistive
Numeric/alphabetical input
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Connection for mouse/
keyboard/barcode reader
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
–
–
Yes
Yes
Operating mode
Emergency STOP button
• 2-channel, positively
latched
2/56
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Technical specifications (continued)
SIMATIC Mobile Panel
277 IWLAN
277(F) IWLAN
Communication via
WLAN (PROFINET)
Communication via
WLAN (PROFINET)
with integrated handwheel, key-operated
switch and two illuminated
pushbuttons
Communication via
WLAN (PROFINET) with
enabling button and
emergency STOP button
Communication via
WLAN (PROFINET)
with enabling button
and emergency STOP
button, handwheel, keyoperated switch and two
illuminated pushbuttons
Acknowledgement button
–
–
2-channel, Number
of settings: 3
2-channel, Number
of settings: 3
Illuminated pushbutton
No
Yes
No
Yes
Handwheel
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Certifications
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
• TÜV safety certification
–
–
Yes
Yes
• BGIA safety certification
–
–
Yes
Yes
• Safety Integrity Level to
IEC 61508
–
–
3
3
• Performance Level to EN
ISO 13849-1
–
–
e
e
• Safety category according
to EN954-1
–
–
Safety category according
to EN954-1 (enabling
button, STOP button if
present) 4
Safety category according
to EN954-1 (enabling
button, STOP button if
present) 4
max. relative humidity
(in %)
80 %
80 %
80 %
80 %
Drop height
1.2 m
1.2 m
1.2 m
1.2 m
• Operation
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
• Transport, storage
-20 to +60°C
-20 to +60°C
-20 to +60°C
-20 to +60°C
Status LEDs
Yes
Yes
Yes
Yes
• LED for safe
Yes
Yes
Yes
Yes
• LED for communication
Yes
Yes
Yes
Yes
• LED for battery
Yes
Yes
Yes
Yes
Vibrations
Yes
Yes
Yes
Yes
Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
USB
1 x USB
1 x USB
1 x USB
1 x USB
Ethernet
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
WLAN
Yes
Yes
Yes
Yes
Supports standards
According to IEEE 802.11a
According to IEEE 802.11a
According to IEEE 802.11a
According to IEEE 802.11a
Supports channels
(acc. to IEEE 802.11a)
Channel 34, Channel 36,
Channel 38, Channel 40,
Channel 42, Channel 44,
Channel 46, Channel 48,
Channel 52, Channel 56,
Channel 60, Channel 64,
Channel 149, Channel 153,
Channel 157, Channel 161
Channel 34, Channel 36,
Channel 38, Channel 40,
Channel 42, Channel 44,
Channel 46, Channel 48,
Channel 52, Channel 56,
Channel 60, Channel 64,
Channel 149, Channel 153,
Channel 157, Channel 161
Channel 34, Channel 36,
Channel 38, Channel 40,
Channel 42, Channel 44,
Channel 46, Channel 48,
Channel 52, Channel 56,
Channel 60, Channel 64,
Channel 149, Channel 153,
Channel 157, Channel 161
Channel 34, Channel 36,
Channel 38, Channel 40,
Channel 42, Channel 44,
Channel 46, Channel 48,
Channel 52, Channel 56,
Channel 60, Channel 64,
Channel 149, Channel 153,
Channel 157, Channel 161
Supports channels
(acc. to IEEE 802.11b and
IEEE 802.1g)
Channels 1 to 11,
Channel 12, Channel 13,
Channel 14
Channels 1 to 11,
Channel 12, Channel 13,
Channel 14
Channels 1 to 11,
Channel 12, Channel 13,
Channel 14
Channels 1 to 11,
Channel 12, Channel 13,
Channel 14
Operating mode
(continued)
Degree of protection
IP65 housing
Certifications & Standards
Ambient conditions
Temperature
Type of output
Interfaces
Siemens ST 80 · 2009
2/57
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Technical specifications (continued)
SIMATIC Mobile Panel
277 IWLAN
277(F) IWLAN
Communication via
WLAN (PROFINET)
Communication via
WLAN (PROFINET)
with integrated handwheel, key-operated
switch and two illuminated
pushbuttons
Communication via
WLAN (PROFINET) with
enabling button and
emergency STOP button
Communication via
WLAN (PROFINET)
with enabling button
and emergency STOP
button, handwheel, keyoperated switch and two
illuminated pushbuttons
Country approval
(radio)
Australia, Belgium,
Denmark, Germany, Finland,
France, Greece, Great
Britain, Ireland, Iceland,
Italy, Japan, Liechtenstein,
Luxemburg, Netherlands,
Norway, Austria, Poland,
Portugal, Sweden,
Switzerland, Spain, South
Africa, Czech Republic,
Turkey, Hungary, USA
Australia, Belgium,
Denmark, Germany,Finland,
France, Greece, Great
Britain, Ireland, Iceland,
Italy, Japan, Liechtenstein,
Luxemburg, Netherlands,
Norway, Austria, Poland,
Portugal, Sweden,
Switzerland, Spain, South
Africa, Czech Republic,
Turkey, Hungary, USA
Australia, Belgium,
Denmark, Germany,Finland,
France, Greece, Great
Britain, Ireland, Iceland,
Italy, Japan, Liechtenstein,
Luxemburg, Netherlands,
Norway, Austria, Poland,
Portugal, Sweden,
Switzerland, Spain, South
Africa, Czech Republic,
Turkey, Hungary, USA
Australia, Belgium,
Denmark, Germany,Finland,
France, Greece, Great
Britain, Ireland, Iceland,
Italy, Japan, Liechtenstein,
Luxemburg, Netherlands,
Norway, Austria, Poland,
Portugal, Sweden,
Switzerland, Spain, South
Africa, Czech Republic,
Turkey, Hungary, USA
Encryption
WEP, WPA
WEP, WPA
WEP, WPA
WEP, WPA
Windows CE
Windows CE
Windows CE
Windows CE
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
Applications/options
Internet Explorer, [email protected]
Service , [email protected] Access
Internet Explorer, [email protected]
Service , [email protected] Access
Internet Explorer, [email protected]
Service , [email protected] Access
Internet Explorer, [email protected]
Service , [email protected] Access
Number of Visual Basic
scripts
50
50
50
50
Task planner
Yes
Yes
Yes
Yes
Help system
Yes
Yes
Yes
Yes
Status/control
With SIMATIC S7
With SIMATIC S7
With SIMATIC S7
With SIMATIC S7
2
WLAN (continued)
Operating systems
Operating system
Processor
Processor
Functionality under
WinCC flexible
Message system
• Number of messages
4,000
4,000
4,000
4,000
• Bit messages
Yes
Yes
Yes
Yes
• Analog messages
Yes
Yes
Yes
Yes
• Message buffer
Circulating buffer (n x 512
Entries), Retentive,
maintenance-free
Circulating buffer (n x 512
Entries), Retentive,
maintenance-free
Circulating buffer (n x 512
Entries), Retentive,
maintenance-free
Circulating buffer (n x 512
Entries), Retentive,
maintenance-free
Recipes
• Recipes
300
300
300
300
• Data records per recipe
500
500
500
500
• Entries per data record
1000
1000
1000
1000
• Recipe memory
64 kByte integrated Flash,
expandable
64 kByte integrated Flash,
expandable
64 kByte integrated Flash,
expandable
64 kByte integrated Flash,
expandable
Number of process images
• Process images
500
500
500
500
• Variables
2,048
2,048
2,048
2,048
• Limit values
Yes
Yes
Yes
Yes
• Multiplexing
Yes
Yes
Yes
Yes
Image elements
• Text objects
10000 Text elements
10000 Text elements
10000 Text elements
10000 Text elements
• Graphics object
Bitmaps, Icons, Vector
graphics
Bitmaps, Icons, Vector
graphics
Bitmaps, Icons, Vector
graphics
Bitmaps, Icons, Vector
graphics
• Dynamic objects
Diagrams / curves,
Diagrams / curves,
Diagrams / curves,
Diagrams / curves,
Bar graphs, Sliders, Analog Bar graphs, Sliders, Analog Bar graphs, Sliders, Analog Bar graphs, Sliders, Analog
display, Hidden buttons
display, Hidden buttons
display, Hidden buttons
display, Hidden buttons
2/58
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Technical specifications (continued)
SIMATIC Mobile Panel
277 IWLAN
277(F) IWLAN
Communication via
WLAN (PROFINET)
Communication via
WLAN (PROFINET)
with integrated handwheel, key-operated
switch and two illuminated
pushbuttons
Communication via
WLAN (PROFINET) with
enabling button and
emergency STOP button
Communication via
WLAN (PROFINET)
with enabling button
and emergency STOP
button, handwheel, keyoperated switch and two
illuminated pushbuttons
Functionality under
WinCC flexible
(Fortsetzung)
Lists
• Text lists
500
500
500
500
• Graphics list
400
400
400
400
• Libraries
Yes
Yes
Yes
Yes
• Number of archives per
project
20
20
20
20
• Number of measuring
points per project
20
20
20
20
• Number of entries per archive
10,000
10,000
10,000
10,000
• Memory location
Multi Media Card
Multi Media Card
Multi Media Card
Multi Media Card
Archiving
Security
• Number of user groups
50
50
50
50
• Passwords exportable
Yes
Yes
Yes
Yes
• Number of user rights
32
32
32
32
Yes
Yes
Yes
Yes
Messages, Report
(shift log), PROFINET
Messages, Report
(shift log), PROFINET
Messages, Report
(shift log), PROFINET
Messages, Report
(shift log), PROFINET
Data medium support
• Multi Media Card
Recording
• Recording/Printing
Languages
• Online languages
16
16
16
16
• Configuration languages
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK,
FIN, GR, J, KP/ROK, NL, N,
PL, P, RUS, S, CZ/SK, TR, H
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK,
FIN, GR, J, KP/ROK, NL, N,
PL, P, RUS, S, CZ/SK, TR, H
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK,
FIN, GR, J, KP/ROK, NL, N,
PL, P, RUS, S, CZ/SK, TR, H
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK,
FIN, GR, J, KP/ROK, NL, N,
PL, P, RUS, S, CZ/SK, TR, H
• Fonts
Tahoma, Arial, Courier New,
WinCC flexible-Standard,
Ideographic languages, all
freely scalable
Tahoma, Arial, Courier New,
WinCC flexible-Standard,
Ideographic languages, all
freely scalable
Tahoma, Arial, Courier New,
WinCC flexible-Standard,
Ideographic languages, all
freely scalable
Tahoma, Arial, Courier New,
WinCC flexible-Standard,
Ideographic languages, all
freely scalable
• Transfer of configuration
USB, Ethernet, Automatic
transfer recognition
USB, Ethernet, Automatic
transfer recognition
USB, Ethernet, Automatic
transfer recognition
USB, Ethernet, Automatic
transfer recognition
• Wireless LAN
Yes
Yes
Yes
Yes
S7-200, S7- 300/400, See
section "System Links"
S7-200, S7- 300/400, See
section "System Links"
S7-200, S7- 300/400, See
section "System Links"
S7-200, S7- 300/400, See
section "System Links"
Yes
Yes
Yes
254
254
254
255
255
255
Transfer (Upload/Download)
Process coupling
• Connection to controller
Yes
• Zones
- Number of zones per
254
project, max.
- Number of transponders 255
for zones per project,
max.
• Effective range
- Number of effective
ranges per project, max.
- Number of transponders
for effective ranges per
project, max.
Yes
Yes
–
–
127
127
–
–
127
127
Siemens ST 80 · 2009
2/59
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Technical specifications (continued)
SIMATIC Mobile Panel
2
277 IWLAN
277(F) IWLAN
Communication via
WLAN (PROFINET)
Communication via
WLAN (PROFINET)
with integrated handwheel, key-operated
switch and two illuminated
pushbuttons
Communication via
WLAN (PROFINET) with
enabling button and
emergency STOP button
Communication via
WLAN (PROFINET)
with enabling button
and emergency STOP
button, handwheel, keyoperated switch and two
illuminated pushbuttons
Yes
Yes
Yes
Yes
256
256
256
256
Yes
Yes
Yes
Yes
2m
2m
2m
2m
8m
8m
8m
8m
Plastic
Plastic
Plastic
Plastic
290 mm / 103 mm
290 mm / 103 mm
290 mm / 103 mm
290 mm / 103 mm
2.2 kg
2.2 kg
2.2 kg
2.2 kg
Functionality under
WinCC flexible
(Fortsetzung)
• Transponder
- Number of transponders
per project, max.
- Adjustable distance
range
- Adjustable distance,
Min.
- Adjustable distance,
Max.
Mechanics
Type of housing (front)
Dimensions
Housing diameter/
depth (mm)
Weights
Weight
■ Ordering data
Order No.
SIMATIC Mobile Panel 277
IWLAN
• Communication via WLAN
(PROFINET)
F
6AV6 645-0DD01-0AX0
F
• Communication via WLAN
(PROFINET)
with integrated handwheel,
key switch and two illuminated
pushbuttons
6AV6 645-0DE01-0AX0
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
2/60
Order No.
SIMATIC Mobile Panel 277F
IWLAN
Siemens ST 80 · 2009
• Communication via WLAN
(PROFINET)
with enable button and
emergency stop button
F
6AV6 645-0DB01-0AX0
F
• Communication via WLAN
(PROFINET)
with enable button and
emergency stop button
with integrated handwheel,
key switch, and two illuminated
pushbuttons
6AV6 645-0DC01-0AX0
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Ordering data
Order No.
Order No.
Accessories
Further IWLAN Access Point versions:
Note: Please order the table-top
power supply or charging station
as well. Required for charging the
battery:
SCALANCE W-784 Access
Points
6GK5 784-1AA30-...
IWLAN Access Points with
integrated radio interfaces (see
Catalog IK PI), radio networks
IEEE 802.11b/g/a/h at 2.4/5 GHz
up to 54 Mbit/s. National
approvals; WPA2/AES; Power
over Ethernet (PoE), degree of
protection IP30 (-20 °C to +60 °C);
scope of delivery: Mounting
hardware, 24 V DC terminal
block; manual on CD-ROM;
German/English;
(see Catalog IK PI)
SCALANCE W-786 Access
Points
6GK5 786-...
IWLAN Access Points with
integrated radio interfaces (see
Catalog IK PI); radio networks
IEEE 802.11b/g/a/h at 2.4/5 GHz
up to 54 Mbit/s. National
approvals; WPA2/AES; Power
over Ethernet (PoE), degree of
protection IP65 (-40°C to +70°C);
scope of delivery: Mounting
hardware, 48 V DC terminal
block; manual on CD-ROM;
German/English;
(see Catalog IK PI)
SCALANCE W-788 Access
Points
6GK5 788-...
IWLAN Access Points with
integrated radio interfaces (see
Catalog IK PI); radio networks
IEEE 802.11b/g/a/h at 2.4/5 GHz
up to 54 Mbit/s. National
approvals; WPA2/AES; Power
over Ethernet (PoE), degree of
protection IP65 (-20°C to +60°C);
scope of delivery: 2 ANT795-4MR
antennas, IP67 hybrid plug-in
connector, mounting hardware,
manual on CD-ROM,
German/English
(see Catalog IK PI)
• Table-top power supply incl.
power cable for EU, US, UK, JP
(only suitable for operation
under laboratory/office
conditions)
6AV6 671-5CN00-0AX1
• Charger for safe storage and
charging the device incl. lock for
securing the device in the
charger. Charging capabilities
for up to two additional batteries
6AV6 671-5CE00-0AX0
• Additional battery with LED
indicator for indicating the
charge status
6AV6 671-5CL00-0AX0
• Transponder incl. batteries
(3x AA)
6AV6 671-5CM00-0AX0
• Service pack for Mobile Panel
277(F) IWLAN contains
accessories pack for Mobile
Panel 277 (labeling strip cover),
battery compartment cover
(device), backup battery, cover
left/right (charger), power
supply connector counterpart
(charger), replacement key
(charger)
6AV6 671-5CA00-0AX1
SCALANCE W-786 Access
Points for SIMATIC Mobile
Panel 277(F) IWLAN
• IWLAN Access Points with
integrated radio interfaces;
radio networks;
IEEE 802.11b/g/a/h at 2.4/5 GHz
up to 54 Mbit/s. National
approvals; WPA2/AES; Power
over Ethernet (PoE), degree of
protection IP65 (-40 °C to
+70 °C); scope of delivery:
Mounting hardware,
48 V DC terminal block; manual
on CD-ROM; German/English;
PS791-2DC power supply
S
6GK5 791-2DC00-0AA0
S
6GK5 791-2AC00-0AA0
2
• 24 V DC power supply for
installation in SCALANCE W-786
products; operating instructions
in German/English
SCALANCE W786-2RR
IWLAN Dual Access Point with
two integrated radio interface for
setting up radio links with iPCF;
RJ45 connection
PS791-2AC power supply
Four internal antennas
• National approvals for
operation outside the U.S.
R
6GK5 786-2BA60-6AA0
• National approvals for
operation within the U.S.
R
6GK5 786-2BA60-6AB0
SCALANCE W786-1PRO
• 110 V AC to 230 V AC power
supply for installation in
SCALANCE W-786 products;
operating instructions in
German/English
Other compatible accessories:
see HMI accessories,
from page 2/158
• Wall mounting bracket for
Mobile Panels
IWLAN Access Points with built-in
wireless interface RJ45 connection
• MultiMedia memory card
• Mobile Panel 277 cover foil
Two internal antennas
• National approvals for
operation outside the U.S.
R
6GK5 786-1BA60-2AA0
• Key labeling strips for Mobile
Panel 277
• National approvals for
operation within the U.S.
R
6GK5 786-1BA60-2AB0
• Spare key for Mobile Panels
R) Subject to export regulations: AL: 5A002A1A2 and ECCN: 5A002ENC3
S) Subject to export regulations: AL: N and ECCN: 5A002ENC3
Siemens ST 80 · 2009
2/61
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Ordering data
2
Order No.
Order No.
Further IWLAN Access Point versions:
Documentation (to be ordered separately)
SIMATIC Mobile Panel 277 (F)
IWLAN starter kit
Getting Started Mobile Panel
277(F) IWLAN
for
• Mobile Panel 277 IWLAN
F
• Mobile Panel 277F IWLAN
F
• German
available as PDF
6AV6 651-5GA01-0AA0
• English
available as PDF
6AV6 651-5HA01-0AA0
User Manual WinCC flexible
Compact/Standard/Advanced
Configuration
with SIMATIC WinCC flexible
see HMI Software
Documentation (to be ordered separately)
Function Manual "Fail-Safe
Operation of the Mobile Panel
277F IWLAN"1)
• German
6AV6 691-1AB01-2AA0
• English
6AV6 691-1AB01-2AB0
• Japanese
6AV6 691-1AB01-2AJ0
Mobile Panel 277F IWLAN
Operating Instructions
• German
6AV6 691-1DQ01-2AA0
• English
6AV6 691-1DQ01-2AB0
• French
6AV6 691-1DQ01-2AC0
• Italian
6AV6 691-1DQ01-2AD0
• Spanish
6AV6 691-1DQ01-2AE0
Mobile Panel 277 IWLAN
Operating Instructions
• German
6AV6 691-1DM01-2AA0
• English
6AV6 691-1DM01-2AB0
• French
6AV6 691-1DM01-2AC0
• Italian
6AV6 691-1DM01-2AD0
• Spanish
6AV6 691-1DM01-2AE0
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
1)
Function manual enclosed with the Mobile Panel 277(F) IWLAN units is
printed in German. Please order other languages separately.
2/62
Siemens ST 80 · 2009
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
WinCC flexible Communication
User Manual
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
Accessories
Accessories for Mobile Panels
see HMI accessories
from page 2/158
© Siemens AG 2008
Operator Control and Monitoring Devices
Mobile Panels — 270 series
SIMATIC Mobile Panel 277 (F) IWLAN
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
2
155
117
9
45
90
8°
103 mm
129 mm
Mobile Panel 277(F) IWLAN – Front and side view
172
G_ST80_XX_00298
ø 290 mm
G_ST80_XX_00299
38,5
162
Transponder
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/mobile-panels
85
Note:
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, you will find information on ordering additional
and standard industry products as well as possibilities for
customer-specific modifications and adjustments.
208
72
G_ST80_XX_00297
61
198
343
160
Charger
Siemens ST 80 · 2009
2/63
© Siemens AG 2008
Operator Control and Monitoring Devices
Basic Panels
Basic Panels
■ Overview
■ Benefits
• Integral component of Totally Integrated Automation (TIA):
Increased productivity, minimum engineering overhead,
reduction in life-cycle costs
- Can be used even where installation space is restricted
thanks to vertical configuring (4" and 6" devices)
- Short configuring and commissioning times
- Service-friendly thanks to maintenance-free design and long
service life of the backlighting display
• Simple and user-friendly representation of process values
thanks to, for example, input/output fields, vector graphics,
trend curves, bar charts, text and bitmaps
• Graphics library available with off-the-shelf picture objects
• Can be used worldwide:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
- You can switch between up to 5 languages online
- Language-dependent texts and graphics
2
• The ideal entry level series of 3.8" to 15" for operating and
monitoring simple machines and plants
• Clear process representation thanks to use of pixel-graphics
displays
• Intuitive operation using Touch and tactile function keys
• Equipped with all the necessary basic functions such as
alarm logging, recipe management, plots, vector graphics,
and language switching
• Simple connection to the controller via integral Ethernet
interface or separate version with RS485/422
• Flexible scalability within the HMI family thanks to configuring
with WinCC flexible
2/64
Siemens ST 80 · 2009
■ Application
The SIMATIC HMI Basic Panels can be used wherever simple
machines and plants are controlled and monitored locally – in
production, process and building automation alike. They are
used in the most diverse sectors and applications.
© Siemens AG 2008
Operator Control and Monitoring Devices
Basic Panels
Basic Panels
■ Design
The SIMATIC HMI Basic Panels are installation-compatible with
the existing touch devices of the product family of Panels and
Multi Panels.
• KTP400 Basic mono
3.8" STN mono
1 Ethernet interface (TCP/IP)
Touch screen and 4 tactile function keys
• KTP600 Basic mono
5.7" STN mono
1 Ethernet interface (TCP/IP)
Touch screen and 6 tactile function keys
• KTP600 Basic color
5.7" TFT with 256 colors
1 Ethernet interface (TCP/IP) or 1 RS 485/422 interface
(separate version)
Touch screen and 6 tactile function keys
• KTP1000 Basic color
10.4" TFT with 256 colors
1 Ethernet interface (TCP/IP) or 1 RS 485/422 interface
(separate version)
Touch screen and 8 tactile function keys
• TP1500 Basic color
15.1" TFT with 256 colors
1 Ethernet interface (TCP/IP)
Touch screen
• No slot for SD/CF/MultiMedia Card, no USB interface
■ Function
• Permanent window and template concept for creating screen
templates
• Input/output fields
for displaying and modifying process parameters
• Buttons
are used for direct triggering of functions and actions. Up to
16 functions can be configured simultaneously on buttons.
• Graphics
can be used as icons instead of text to "label" function keys or
buttons. They can also be used as full-screen background images.
The configuration tool contains a library with extensive graphics and diverse objects. All editors with an OLE interface can
be used as graphics editors, e.g. PaintShop, Designer or
CorelDraw, etc.
• Vector graphics
Simple geometric basic forms (line, circle and rectangle) can
be created direct in the configuring tool
• Fixed texts
for labeling function keys, process images and process
values in different font sizes
• Curve functions and bars
are used for graphical display of dynamic values
• Language switching:
- 5 online languages, 32 configuration languages including
Asian and Cyrillic character sets
- Language-dependent texts and graphics
• User administration (security) in accordance with the
requirements of the different sectors
- Authentication with user ID and password
- User-group-specific rights
• Signaling system
- Discrete alarms
- Analog messages
- Freely definable message classes (e.g. status/fault
messages) for defining acknowledgment response and
displaying message events
- Message history
• Recipe management
• Help texts
for process screens, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Indicator light
for indicating machine and plant statuses
• Task planner for cyclic execution of functions
• Template concept
• Creation of picture templates (picture elements configured
in the template appear in every image)
• Simple maintenance and configuration thanks to:
- Backup/restore of configuration, operating system and firmware on a PC using ProSave
- Configuration download via MPI/PROFIBUS DP or Ethernet
- Automatic transfer identification
- Individual contrast setting and calibration
- Clean screen
- No battery required
Configuration
The configuration is implemented using the engineering
software SIMATIC WinCC flexible 2008 Compact.
■ Integration
The Basic Panels can be connected to:
• SIMATIC S7 controllers
• Non-Siemens controllers (applies for DP devices)
- Allen Bradley DF1
- Modicon Modbus
Note:
Further information can be found under "System interfaces".
Siemens ST 80 · 2009
2/65
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Basic Panels
Basic Panels
■ Technical specifications
SIMATIC
Basic Panel
2
KTP400 Basic
mono PN
KTP600 Basic
mono PN
KTP600 Basic
color PN
KTP600 Basic
color DP
KTP1000 Basic
color PN
KTP1000 Basic
color DP
TP1500 Basic
color PN
Supply voltage
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
Permissible
range
+19,2 V DC ...
+28,8 V DC
+19,2 V DC ...
+28,8 V DC
+19,2 V DC ...
+28,8 V DC
+19,2 V DC ...
+28,8 V DC
+20,4 V DC ...
+28,8 V DC
+20,4 V DC ...
+28,8 V DC
+20,4 V DC ...
+28,8 V DC
Supply voltage
Memory
• Type of storage Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
512 kB
512 kB
512 kB
512 kB
1024 kB
1024 kB
1024 kB
Software clock,
not battery
backed
Software clock,
not battery
backed
Software clock,
not battery
backed
Software clock,
not battery
backed
Software clock,
not battery
backed
Software clock,
not battery
backed
Software clock,
not battery
backed
WinCC flexible
Compact Version 2008 SP11)
or higher (to be
ordered separately)
WinCC flexible
Compact Version 2008 SP11)
or higher (to be
ordered separately)
WinCC flexible
Compact Version 2008 SP11)
or higher (to be
ordered separately)
WinCC flexible
Compact Version 2008 SP11)
or higher (to be
ordered separately)
WinCC flexible
Compact Version 2008 or
higher (to be
ordered separately)
WinCC flexible
Compact Version 2008 or
higher (to be
ordered separately)
WinCC flexible
Compact Version 2008 or
higher (to be
ordered separately)
Display type
STN, 4 shades
of gray
STN, 4 shades
of gray
TFT, 256 colors
TFT, 256 colors
TFT, 256 colors
TFT, 256 colors
TFT, 256 colors
Size
3,8"
5,7"
5,7"
5,7"
10,4"
10,4"
15"
Resolution
(WxH in pixel)
320 x 240
320 x 240
320 x 240
320 x 240
640 x 480
640 x 480
1024 x 768
MTBF
backlighting
(at 25 °C)
app. 30 000 h
app. 50 000 h
app. 50 000 h
app. 50 000 h
app. 50 000 h
app. 50 000 h
app. 50 000 h
Membrane
keyboard
Membrane
keyboard
Membrane
keyboard
Membrane
keyboard
Membrane
keyboard
Membrane
keyboard
Touch screen
• Memory
usable for
project data
Time
Clock
Configuration
Configuration
tool
Display
Operating mode
Operating
elements
Key and Touch
Key and Touch
Key and Touch
Key and Touch
Key and Touch
Key and Touch
Touch
Function keys,
programmable
4
6
6
6
8
8
None
Touch screen
analog, resistive
analog, resistive
analog, resistive
analog, resistive
analog, resistive
analog, resistive
analog, resistive
Numeric/alphabetical input
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Connection for
mouse/keyboard/ barcode
reader
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
-/-/-
Degree of protection
Front
IP65, enclosure IP65, enclosure IP65, enclosure IP65, enclosure IP65, enclosure IP65, enclosure IP65, enclosure
type 4X/type 12 type 4X/type 12 type 4X/type 12 type 4X/type 12 type 4X/type 12 type 4X/type 12 type 4X/type 12
(indoor use only) (indoor use only) (indoor use only) (indoor use only) (indoor use only) (indoor use only) (indoor use only)
Rear
IP20
IP20
IP20
IP20
IP20
IP20
IP20
CE, UL, cULus,
enclosure type
4X/type 12
CE, UL, cULus,
enclosure type
4X/type 12
CE, UL, cULus,
enclosure type
4X/type 12
CE, UL, cULus,
enclosure type
4X/type 12
CE, UL, cULus,
enclosure type
4X/type 12
CE, UL, cULus,
enclosure type
4X/type 12
Certifications & Standards
Certifications
CE, UL, cULus,
enclosure type
4X/type 12
Ambient conditions
Mounting
position
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Max. permissible angle of
incliniation
without external
ventilation
+/ - 35 °
+/ - 35 °
+/ - 35 °
+/ - 35 °
+/ - 35 °
+/ - 35 °
+/ - 35 °
Max. relative
humidity (in %)
90 %
90 %
90 %
90 %
90 %
90 %
90 %
1)
Delivery expected: 1st quarter 2009.
2/66
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Basic Panels
Basic Panels
■ Technical specifications (continued)
SIMATIC
Basic Panel
KTP400 Basic
mono PN
KTP600 Basic
mono PN
KTP600 Basic
color PN
KTP600 Basic
color DP
KTP1000 Basic
color PN
KTP1000 Basic
color DP
TP1500 Basic
color PN
• Operation (ver- 0 °C ... +50 °C
tical installat.)
0 °C ... +50 °C
0 °C ... +50 °C
0 °C ... +50 °C
0 °C ... +50 °C
0 °C ... +50 °C
0 °C ... +50 °C
• Operation
0 °C ... +40 °C
(max. tilt angle)
0 °C ... +40 °C
0 °C ... +40 °C
0 °C ... +40 °C
0 °C ... +40 °C
0 °C ... +40 °C
0 °C ... +40 °C
Ambient conditions (continued)
Temperature
• Transportation, -20 °C ... +60 °C -20 °C ... +60 °C -20 °C ... +60 °C -20 °C ... +60 °C -20 °C ... +60 °C -20 °C ... +60 °C -20 °C ... +60 °C
storage
I/O/Options
none
none
none
none
Interfaces
1 x Ethernet
(RJ45)
1 x Ethernet
(RJ45)
1 x Ethernet
(RJ45)
1 x RS422,
1 x Ethernet
1 x RS485 (max. (RJ45)
1.5 MBit/s)
1 x RS422,
1 x Ethernet
1 x RS485 (max. (RJ45)
1.5 MBit/s)
USB
No
No
No
No
No
No
No
PC card slot
No
No
No
No
No
No
No
CF card slot
No
No
No
No
No
No
No
Multi Media/
Card-Slot
No
No
No
No
No
No
No
ARM
ARM
ARM
ARM
ARM
ARM
ARM
not possible
not possible
not possible
not possible
not possible
not possible
I/O
none
none
none
Interfaces
Slots
Processor
Processor
Functionality under WinCC flexible
Number of Visual not possible
Basic scripts
Task planner
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Help system
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Status/control
not possible
not possible
not possible
not possible
not possible
not possible
not possible
• Number of
messages
200
200
200
200
200
200
200
• Bit messages
Yes
Yes
Yes
Yes
Yes
Yes
Yes
• Analog
messages
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Message system
• Message buffer Ring buffer
Ring buffer
Ring buffer
Ring buffer
Ring buffer
Ring buffer
Ring buffer
(n x 256 entries), (n x 256 entries), (n x 256 entries), (n x 256 entries), (n x 256 entries), (n x 256 entries), (n x 256 entries),
non-retentive
non-retentive
non-retentive
non-retentive
non-retentive
non-retentive
non-retentive
Recipes
• Recipes
5
5
5
5
5
5
5
• Data records
per recipe
20
20
20
20
20
20
20
• Entries per data 20
record
20
20
20
20
20
20
32 kB integr.
Flash
32 kB integr.
Flash
32 kB integr.
Flash
32 kB integr.
Flash
32 kB integr.
Flash
32 kB integr.
Flash
32 kB integr.
Flash
• Process
images
50
50
50
50
50
50
50
• Variables
128
128
128
128
256
256
256
• Limit values
Yes
Yes
Yes
Yes
Yes
Yes
Yes
• Multiplexing
Yes
Yes
Yes
Yes
Yes
Yes
Yes
• Recipe
memory
Number of
process images
Siemens ST 80 · 2009
2/67
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Basic Panels
Basic Panels
■ Technical specifications (continued)
SIMATIC
Basic Panel
2
KTP400 Basic
mono PN
KTP600 Basic
mono PN
KTP600 Basic
color PN
KTP600 Basic
color DP
KTP1000 Basic
color PN
KTP1000 Basic
color DP
TP1500 Basic
color PN
500
500
500
500
500
Functionality under WinCC flexible (continued)
Image elements
• Text objects
500
• Graphics
object
Bit maps, icons, Bit maps, icons, Bit maps, icons, Bit maps, icons, Bit maps, icons, Bit maps, icons, Bit maps, icons,
icon (full-screen) icon (full-screen) icon (full-screen) icon (full-screen) icon (full-screen) icon (full-screen) icon (full-screen)
vector graphics vector graphics vector graphics vector graphics vector graphics vector graphics vector graphics
500
• Dynamic
objects
Diagrams, bar
graphs, curve
functions
Diagrams, bar
graphs, curve
functions
Diagrams, bar
graphs, curve
functions
Diagrams, bar
graphs, curve
functions
Diagrams, bar
graphs, curve
functions
Diagrams, bar
graphs, curve
functions
Diagrams, bar
graphs, curve
functions
Lists
• Text lists
150
150
150
150
150
150
150
• Graphics list
100
100
100
100
100
100
100
• Libraries
Yes
Yes
Yes
Yes
Yes
Yes
Yes
• Number of user 50
groups
50
50
50
50
50
50
• Passwords
exportable
32
32
32
32
32
32
32
• Number of
users
Yes
Yes
Yes
Yes
Yes
Yes
Yes
• PC card
No
No
No
No
No
No
No
• CF card
No
No
No
No
No
No
No
• Multi Media
card
No
No
No
No
No
No
No
• Recording/
printing
No
No
No
No
No
No
No
• Printer driver
No
No
No
No
No
No
No
US American
(English)
US American
(English)
US American
(English)
US American
(English)
US American
(English)
US American
(English)
Security
Data medium
support
Recording
Fonts
• Keyboard fonts US American
(English)
Languages
• Online
languages
5
5
5
5
5
5
5
• Configuration
languages
D, GB, F, I, E,
CHN "traditional", CHN
"simplified", DK,
FIN, GR, J, KP /
ROK, NL, N, PL,
P, RUS, S, CZ /
SK, TR, H
D, GB, F, I, E,
CHN "traditional", CHN
"simplified", DK,
FIN, GR, J, KP /
ROK, NL, N, PL,
P, RUS, S, CZ /
SK, TR, H
D, GB, F, I, E,
CHN "traditional", CHN
"simplified", DK,
FIN, GR, J, KP /
ROK, NL, N, PL,
P, RUS, S, CZ /
SK, TR, H
D, GB, F, I, E,
CHN "traditional", CHN
"simplified", DK,
FIN, GR, J, KP /
ROK, NL, N, PL,
P, RUS, S, CZ /
SK, TR, H
D, GB, F, I, E,
CHN "traditional", CHN
"simplified", DK,
FIN, GR, J, KP /
ROK, NL, N, PL,
P, RUS, S, CZ /
SK, TR, H
D, GB, F, I, E,
CHN "traditional", CHN
"simplified", DK,
FIN, GR, J, KP /
ROK, NL, N, PL,
P, RUS, S, CZ /
SK, TR, H
D, GB, F, I, E,
CHN "traditional", CHN
"simplified", DK,
FIN, GR, J, KP /
ROK, NL, N, PL,
P, RUS, S, CZ /
SK, TR, H
• Fonts
WinCC flexible
Standard, symbol languages
WinCC flexible
Standard, symbol languages
WinCC flexible
Standard, symbol languages
WinCC flexible
Standard, symbol languages
WinCC flexible
Standard, symbol languages
WinCC flexible
Standard, symbol languages
WinCC flexible
Standard, symbol languages
Transfer
(Upload/Download)
Ethernet, automatic transfer
recognition
Ethernet, automatic transfer
recognition
Ethernet, automatic transfer
recognition
MPI/PROFIBUS Ethernet, autoDP, automatic
matic transfer
transfer recogni- recognition
tion
MPI/PROFIBUS Ethernet, autoDP, automatic
matic transfer
transfer recogni- recognition
tion
S7-200, S7- 300/
400, WinAC see
"System interfaces"
S7-200, S7- 300/
400, WinAC see
"System interfaces"
S7-200, S7- 300/
400, WinAC see
"System interfaces"
S7-200, S7- 300/
400, WinAC,
Allen Bradley
(DF1), Modicon
(Modbus), see
"System interfaces"
S7-200, S7- 300/
400, WinAC,
Allen Bradley
(DF1), Modicon
(Modbus), see
"System interfaces"
Process
coupling
• Connection to
controller
2/68
Siemens ST 80 · 2009
S7-200, S7- 300/
400, WinAC see
"System interfaces"
S7-200, S7- 300/
400, WinAC see
"System interfaces"
© Siemens AG 2008
Operator Control and Monitoring Devices
Basic Panels
Basic Panels
■ Technical specifications (continued)
SIMATIC
Basic Panel
KTP400 Basic
mono PN
KTP600 Basic
mono PN
KTP600 Basic
color PN
KTP600 Basic
color DP
KTP1000 Basic
color PN
KTP1000 Basic
color DP
TP1500 Basic
color PN
Functionality under WinCC flexible (continued)
2
Expandability/
openness
• Open Platform
Program
No
No
No
No
No
No
No
140 x 116
214 x 158
214 x 158
214 x 158
335 x 275
335 x 275
400 x 310
197 x 141 / 44
197 x 141 / 44
197 x 141 / 44
310 x 248 / 60
310 x 248 / 60
367 x 289 / 59.9
1.07
1.07
1.07
2.65
2.65
4.2
Dimensions
Front of enclosure (W x H)
in mm
Mounting cutout/ 123 x 99 / 40
Device depth
(W x H/D) in mm
Weights
Weight (kg)
0.32
Siemens ST 80 · 2009
2/69
© Siemens AG 2008
Operator Control and Monitoring Devices
Basic Panels
Basic Panels
■ Ordering data
2
Order No.
Order No.
SIMATIC KTP400
Basic mono PN1)
6AV6 647-0AA11-3AX0
Configuration
Starter kit for SIMATIC KTP 400
Basic mono1)
6AV6 652-7AA01-3AA0
• with SIMATIC WinCC flexible
Compact
SIMATIC KTP600
Basic mono PN1)
6AV6 647-0AB11-3AX0
Starter kit for SIMATIC KTP600
Basic mono PN1)
6AV6 652-7BA01-3AA0
SIMATIC KTP600
Basic color DP1)
6AV6 647-0AC11-3AX0
Starter kit for SIMATIC KTP600
Basic color DP1)
6AV6 652-7CA01-3AA0
SIMATIC KTP600
Basic color PN1)
6AV6 647-0AD11-3AX0
Starter kit for SIMATIC KTP600
Basic color PN1)
6AV6 652-7DA01-3AA0
See Section 4
Documentation (to be ordered separately)
You can find the manual for the
Basic Panels on the Internet at
http://support.automation.
siemens.com
User Manual
WinCC flexible Compact/
Standard/Advanced
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
6AV6 691-1AB01-3AE0
SIMATIC KTP1000
Basic color DP
6AV6 647-0AE11-3AX0
• Spanish
Starter kit for SIMATIC KTP1000
Basic color DP
6AV6 652-7EA01-3AA0
User Manual
WinCC flexible Communication
• German
6AV6 691-1CA01-3AA0
SIMATIC KTP1000
Basic color PN
6AV6 647-0AF11-3AX0
• English
6AV6 691-1CA01-3AB0
Starter kit for SIMATIC KTP1000
Basic color PN
6AV6 652-7FA01-3AA0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection
6AV6 691-1SA01-0AX0
SIMATIC TP1500
Basic color PN
6AV6 647-0AG11-3AX0
Starter kits consist of:
• the relevant SIMATIC KTP Basic
Panel
• SIMATIC WinCC flexible Compact engineering software
• SIMATIC HMI Manual Collection
(DVD),
5 languages (English, French,
German, Italian, Spanish), comprising: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
• Ethernet cable on PN devices
• MPI cable on DP devices
(for download and test purposes
only)
• Voucher for Software Update
Service for 1 year
B) Subject to export regulations: AL: N and ECCN: EAR99S
1)
Delivery expected: 1st quarter 2009.
2/70
Siemens ST 80 · 2009
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
Accessories
Accessories for supplementary
ordering
See HMI Accessories,
from page 2/148
© Siemens AG 2008
Operator Control and Monitoring Devices
Basic Panels
Basic Panels
■ Dimensions
All specifications in mm.
2
196
40
6,2
G_ST80_XX_00355
140
140
G_ST80_XX_00356
158
116
98
122
44
214
KTP400 Basic
6,2
KTP600 Basic
309
G_ST80_XX_00357
G_ST80_XX_00358
288
310
247
275
366
400
335
60,2
KTP1000 Basic
59,9
6,2
6,2
TP1500 Basic
■ More information
Additional information is available in the Internet under:
Note:
http://www.siemens.com/panels
Do you require a specific modification to or supplement for the
products described here? Look under "Customized products".
We provide information there about additional and generally
available sector products, and about the customer-specific
modification and adaptation options.
Siemens ST 80 · 2009
2/71
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 73
■ Overview
■ Design
•
•
•
•
•
•
3" 147; LCD, 160 x 48 pixels, monochrome
8 system keys, 4 user-configurable function keys
Numerical and alphanumeric input option via cursor keys
Compact design with low mounting depth
Rugged plastic housing
The front is resistant to various oils, greases and standard
detergents
• Plug-type terminals for a 24 V DC power supply
• RS 485 interface for process connections (MPI,
PROFIBUS DP up to 1.5 Mbit/s) and for configuration
download
2
■ Function
•
•
•
•
•
•
Operator Panel for HMI functions of machines and plants
Graphics in a new dimension: Small and smart
Full graphics 3" LCD, monochrome
8 system keys, 4 freely programmable function keys
All interfaces are on-board (e.g. MPI, PROFIBUS DP)
SIMATIC OP 73 is the successor to the OP3 operator panel
■ Benefits
•
•
•
•
High-contrast display for good readability
Large keys for high operational safety
Simple handling and configuring
Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• Service-friendly through maintenance-free design (no battery)
and high service life of the backlighting
• Graphics library is available complete with ready-to-use
display objects
• Can be used worldwide:
- 32 languages can be configured (including Asiatic and
Cyrillic character sets)
- Up to 5 languages are selectable online
- Language-dependent texts and graphics
■ Application
The OP 73 Operator Panels can be used wherever direct operator control and monitoring of machines and installations is
required locally – whether in production automation, process
automation or building automation. They are in use in an extensive range of sectors and applications.
Compatible with OP3
• Same installation cutout as OP3
• The OP3 configurations can be loaded from ProTool/Lite,
ProTool and ProTool/Pro
Migration manual with description of the important differences
over OP3 or ProTool
2/72
Siemens ST 80 · 2009
• Input/output fields;
for displaying and changing process parameters
• Function keys;
for direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on function keys.
• Graphics;
can be used as icons instead of text to "label" function keys or
buttons. They can also be used as simple on-screen graphics.
In the configuration tool, a library is available containing an
extensive range of graphics and a wide variety of objects. All
editors with an OLE interface can be used as graphics editors
(such as PaintShop, Designer or CorelDraw).
• Predefined;
for labeling function keys, process images and process
values in different font sizes
• Bars are used for the graphical display of dynamic values
• Language selection during runtime:
- 5 online languages, 32 configuration languages incl. Asian
and Cyrillic character sets
- Language-dependent texts and graphics
• User administration (security):
- Authentication with user ID and password
- User-group-specific rights
• Message system:
- Discrete alarms
- Analog messages
- Freely definable message classes (e.g., status/fault
messages) for definition of acknowledgment response and
display of message events
- Message history
• Help texts;
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring;
for reliable process control of inputs and outputs
• Indicator light;
for machine and plant status indication
• Scheduler for global function execution
• Template concept;
creation of screen templates (picture elements configured in
the template appear in every screen)
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 73
■ Function (continued)
■ Integration
• Simple maintenance and configuration thanks to:
- Backup and restoration of configuration, operating system
and firmware on a PC using ProSave
- Configuration download using MPI/PROFIBUS DP or serially
by using RS485
- Individual contrast settings
- No batteries are necessary
The OP 73 can be connected to the following:
• SIMATIC S7-200/-300-400
• SIMATIC WinAC Software/Slot PLC
2
Note:
For further information see "System interfaces"
Configuring
SIMATIC WinCC flexible Compact, Standard or Advanced
engineering software Version 2004 SP1 and higher plus HSP is
used for configuration.
For more information about engineering software, see HMI
software/engineering software SIMATIC WinCC flexible.
■ Technical specifications
OP 73
Supply voltage
OP 73
Degree of protection
Supply voltage
24 V DC
Front
IP65, NEMA 4x, (when installed)
permissible range
+20.4 V to +28.8 V DC
Rear
IP20
Rated current
0.1 A
Certifications & Standards
Certifications
Memory
Type of storage
• Type
Flash
• Memory usable for project
data/Options
256 KB usable memory for
user data
Interfaces
Interfaces
Operating system
Clock
Processor
• Type
Software clock, not battery backed
Configuration tool
WinCC flexible Compact Version
2004 SP 1 or higher; HSP OP 73
(to be ordered separately)
Display
Display type
STN, Black/white
Size
3"
Resolution (WxH in pixel)
160 x 48
MTBF backlighting (at 25 °C)
about 100,000 hours
Operating mode
1 x RS485 (max. 1.5 Mbit/s)
Operating systems
Time
Configuration
CE, GL, ABS, BV, DNV, LRS, UL,
CSA, cULus, C-TICK, NEMA 4x
Processor
LINUX
ARM
Functionality under
WinCC flexible
Task planner
Yes
Help system
Yes
Status/control
Not possible
Message system
• Number of messages
500
• Bit messages
Yes
• Analog messages
Yes
• Message buffer
Ring buffer (n x 256 entries),
non-retentive
Operating elements
Membrane keyboard
Function keys, programmable
4 function keys
Number of process images
System keys
8
• Process images
500
Numeric/alphabetical input
Yes / Yes
• Variables
1 000
Connection for mouse/keyboard/barcode reader
-/-/-
• Limit values
Yes
• Multiplexing
Yes
Ambient conditions
Mounting position
Image elements
Vertical
+/- 80°
maximum permissible angle of
incliniation without external ventilation
max. relative humidity (in %)
• Text objects
1,000 text elements
• Graphics object
Bit maps, icons, icon (full-screen)
• dynamic objects
Bar graphs
90%
Temperature
• Operation (vertical installation)
0 °C to +50 °C
• Operation (max. tilt angle)
0 °C to +40 °C
• Transport, storage
-20 °C to +60 °C
Siemens ST 80 · 2009
2/73
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 73
■ Technical specifications
■ Ordering data
OP 73
2
SIMATIC OP 73
Order No.
C
6AV6 641-0AA11-0AX0
D
6AV6 651-1AA01-0AA0
Operator Panel with 3" display,
monochrome, including mounting accessories
Functionality under
WinCC flexible (continued)
Lists
• Text lists
150
• Graphics list
0
• Libraries
Yes
OP 73 starter package
Consisting of:
• OP 73 Operator Panel
• SIMATIC WinCC flexible
Compact engineering software
Security
• Number of user groups
50
• Passwords exportable
Yes
• Number of user rights
32
Recording
• Recording/Printing
-
Fonts
• Keyboard fonts
US American (English)
Languages
• Online languages
5
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
WinCC flexible Standard, symbol
languages
• Fonts
Configuration
with SIMATIC WinCC flexible
see Chapter 4
• German
6AV6 691-1AB01-3AA0
S7-200, S7-300/400, Win AC
see "System interfaces"
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
No
Dimensions
Front of enclosure (W x H)
154 mm x 84 mm
Mounting cutout/Device depth
(W x H/D) in mm
138 mm x 68 mm / 28.5 mm device
depth
Weights
Weight
• Voucher for Software Update
Service for 1 year
User Manual
WinCC flexible Compact/
Standard/Advanced
Expandability/openness
• Open Platform Program
• RS 232/PPI multi-master cable
(for download image update
and image booting)
MPI/PROFIBUS DP, serial, automatic transfer recognition
Process coupling
• Connection to controller
• MPI cable (5 m)
(for download and test purposes
only)
Documentation (to be ordered separately)
Transfer (Upload/Download)
• Transfer of configuration
• SIMATIC HMI Manual Collection
(CD), 5 languages (English,
French, German, Italian,
Spanish), comprising all currently available user manuals,
manuals and communication
manuals for SIMATIC HMI
0.25 kg
User Manual
WinCC flexible Communication
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
B) Subject to export regulations: AL: N and ECCN: EAR99S
C) Subject to export regulations: AL: N and ECCN: EAR99T
D) Subject to export regulations: AL: N and ECCN: 5D992B1
2/74
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 73
■ Dimensions
■ More information
Additional information is available in the Internet under:
All specifications in mm.
http://www.siemens.com/panels
2
Note:
154
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
G_ST80_XX_00144
67,7
84
28,5
Siemens ST 80 · 2009
2/75
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77A
■ Overview
■ Application
OP 77A Operator Panels can be used wherever machines and
systems are controlled and monitored locally – in production,
process and building automation alike. They are used in all
types of sectors and applications.
2
Compatibility with OP7
• Same panel cutout as OP7
• Importing of OP7 configurations from ProTool/Lite, ProTool and
ProTool/Pro
Migration manual with description of most important changes to
OP7 and ProTool:
■ Design
• Compact Operator Panel for operator control and monitoring
of machines and plants
• Graphics in a new dimension – small and smart
• Pixel-graphics 4.5" LC display, monochrome
• 23 system keys, 8 freely-configurable and freely-inscribable
function keys (4 with LEDs)
• All interfaces (e.g. MPI, PROFIBUS DP) are onboard
interfaces.
• Together with OP 77B, successor of the successful OP7
■ Benefits
•
•
•
•
High-contrast display for good readability
Large keys for high operational safety
Simple handling and configuring
Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• Reduction in service and startup costs thanks to maintenance-free design (no battery) and long service life of the
backlighting
• Can be used worldwide:
- 32 languages can be configured (including Asiatic and
Cyrillic character sets)
- Up to 5 languages are selectable online
- Language-dependent texts and graphics
• Graphics library is available complete with ready-to-use
display objects
2/76
Siemens ST 80 · 2009
• 4.5" LCD, 160 x 64 pixels, monochrome
• 23 system keys, 8 freely-configurable and freely-inscribable
function keys (4 with LEDs)
• Numeric and alphanumeric input facilities
• Compact design with shallow installation depth
• Rugged plastic housing
• The front is resistant to various oils, greases and standard
detergents
• Plug-type terminals for connection of a 24 V DC power supply
• RS 485 interface for process links (MPI, PROFIBUS DP up to
1.5 Mbit/s) and for downloading the configuration
■ Function
• Permanent window and template concept for creating screen
templates
• Input/output fields
for displaying and changing process parameters
• Function keys
are used for directly actuating functions and actions. Up to 16
functions can be configured simultaneously on function keys
• Graphics
can be used as icons instead of text to "label" function keys or
buttons. They can also be used as simple on-screen graphics.
In the configuration tool, a library is available containing an extensive range of graphics and a wide variety of objects. All
editors with an OLE interface can be used as graphics editors
(such as PaintShop, Designer or CorelDraw).
• Predefined texts
for labeling function keys, process images and process
values in any character size
• Bars are used for the graphical display of dynamic values
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77A
■ Function (continued)
• Display selection from the PLC
supports operator prompting from the PLC
• Language selection during runtime
- 5 online languages, 32 configuration languages incl. Asian
and Cyrillic character sets
- Language-dependent texts and graphics
• User administration (security) according to the requirements
of the various sectors
- Authentication with user ID and password
- User-group-specific rights
• Signaling system
- Freely definable message classes (e.g., status/fault
messages) for definition of acknowledgment response and
display of message events
- Message history
• Recipe management
• Help texts
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Indicator light
for machine and plant status indication
• Scheduler for cyclic function execution
• Template concept;
picture elements configured in the template appear in every
picture
• Simple maintenance and configuration thanks to:
- Backup and restoration of the configuration, operating
system, data records and firmware on a PC using ProSave
- Configuration download/upload using MPI/PROFIBUS DP
and serially by using RS 485
- Individual contrast settings
- No batteries are necessary
Configuration
SIMATIC WinCC flexible Compact, Standard or Advanced
configuration software Version 2004 SP1 and higher plus HSP is
used for configuration.
For more information about engineering software, see HMI software/engineering software SIMATIC WinCC flexible.
■ Integration
The OP 77A can be connected to the following:
• SIMATIC S7-200/-300-400
• SIMATIC WinAC Software/Slot PLC
■ Technical specifications
OP 77A
Supply voltage
Supply voltage
24 V DC
permissible range
+20.4 V to +28.8 V DC
Rated current
0.2 A
Memory
Type of storage
Type
Flash / RAM
Memory usable for project
data/Options
256 KB usable memory for user
data
Time
Clock
• Type
Software clock, not battery backed
Configuration
Configuration tool
WinCC flexible Compact Version
2004 SP 1 or higher; HSP OP 77
(to be ordered separately)
Display
Display type
STN, Black/white
Size
4.5"
Resolution (W x H in pixel)
160 x 64
MTBF backlighting (at 25 °C)
about 100,000 hours
Operating mode
Operating elements
Membrane keyboard
Function keys, programmable
8 function keys, 4 with LEDs
System keys
23
Numeric/alphabetical input
Yes / Yes
Connection for mouse/keyboard/barcode reader
-/-/-
Ambient conditions
Mounting position
Vertical
+/- 80°
maximum permissible angle of
incliniation without external ventilation
max. relative humidity (in %)
90%
Temperature
• Operation (vertical installation)
0 °C to +50 °C
• Operation (max. tilt angle)
0 °C to +40 °C
• Transport, storage
-20 °C to +60 °C
Degree of protection
Front
IP65, NEMA 4x, NEMA 12 (when
installed)
Rear
IP20
Note:
For further information see "System interfaces"
2
Certifications & Standards
Certifications
CE, GL, ABS, BV, DNV, LRS, FM
Class I Div. 2, UL, CSA, cULus,
EX-Zone 2 (available soon), EXZone 22 (available soon, C-TICK,
NEMA 4x, NEMA 12
Type of output
LED colors
Green
Siemens ST 80 · 2009
2/77
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77A
■ Technical specifications (continued)
OP 77A
interfaces
2
Interfaces
1 x RS422, 1 x RS485
(max. 1.5 Mbit/s)
OP 77A
Functionality under
WinCC flexible (continued
Lists
• Text lists
300
PC card slot
No
• Graphics list
0
CF card slot
No
• Libraries
Yes
Multi Media Card slot
No
Security
USB
No
• Number of user groups
50
Ethernet
No
• Passwords exportable
Yes
• Number of user rights
32
Slots
Operating systems
Operating system
LINUX
Recording
ARM
Fonts
• Recording/Printing
Processor
Processor
• Keyboard fonts
Functionality under
WinCC flexible
US American (English)
Languages
Task planner
Yes
Help system
Yes
Status/control
Not possible
• Online languages
5
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
WinCC flexible Standard, symbol
languages
Message system
• Number of messages
1 000
• Bit messages
Yes
• Analog messages
Yes
Transfer (Upload/Download)
• Message buffer
Ring buffer (n x 256 entries),
non-retentive
• Transfer of configuration
MPI/PROFIBUS DP, serial, automatic transfer recognition
Process coupling
Recipes
• Recipes
5
• Data records per recipe
20
• Entries per data record
20
• Recipe memory
32 kByte integrated Flash
Number of process images
• Connection to controller
S7-200, S7-300/400, Win AC
see "System interfaces"
Expandability/openness
• Open Platform Program
No
Dimensions
Front of enclosure (W x H)
150 mm x 186 mm
1 000
Mounting cutout/Device depth
(W x H/D) in mm
135 mm x 171 mm / 38.5 mm
device depth
• Limit values
Yes
Weight
• Multiplexing
Yes
Weight
• Process images
500
• Variables
Image elements
• Text objects
1,000 text elements
• Graphics object
Bit maps, icons, icon
(full-screen)
• dynamic objects
Bar graphs
2/78
Siemens ST 80 · 2009
0.5 kg
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77A
■ Ordering data
SIMATIC OP 77A
Order No.
C
6AV6 641-0BA11-0AX1
D
6AV6 651-1BA01-0AA0
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
Operator Panel with 4.5" display,
monochrome, incl. mounting
accessories
OP 77A starter package
150
2
38,5
Consisting of:
170
186
• Operator Panel OP 77A
• SIMATIC WinCC flexible
Compact engineering software
• SIMATIC HMI Manual Collection
(CD), 5 languages (English,
French, German, Italian,
Spanish), comprising all
currently available user manuals, manuals and communication manuals for SIMATIC HMI
G_ST80_XX_00087
134
6,2
• MPI cable (5 m)
(for download and test purposes
only)
• RS232/PPI multi-master cable
(for download and image
booting)
■ More information
Additional information is available in the Internet under:
• Voucher for Software Update
Service for 1 year
http://www.siemens.com/panels
Configuration
with SIMATIC WinCC flexible
see Chapter 4
Documentation (to be ordered separately)
User Manual
WinCC flexible Compact/
Standard/Advanced
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
User Manual
WinCC flexible Communication
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
B) Subject to export regulations: AL: N and ECCN: EAR99S
C) Subject to export regulations: AL: N and ECCN: EAR99T
D) Subject to export regulations: AL: N and ECCN: 5D992B1
Siemens ST 80 · 2009
2/79
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77B
■ Overview
■ Benefits
•
•
•
•
2
•
•
•
•
• Compact Operator Panel for operator control and monitoring
of machines and plants
• Graphics in a new dimension – small and smart
• Pixel-graphics 4,5" LCD, monochrome
• 23 system keys, 8 freely-configurable and freely-inscribable
function keys (4 with LEDs)
• All interfaces (e.g. MPI, PROFIBUS DP) are onboard
interfaces.
• Non-Siemens PLCs can be connected using easy-to-use
drivers
• Combined with OP 77A successor of the successful OP 7
•
High-contrast display for good legibility
Large keys for improved operational reliability
Easy to handle and configure
Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
Reduction of service and commissioning costs through:
- Remote downloading of the configuration with automatic
transfer recognition even via WAN (Wide Area Network)
- Maintenance-free design (no battery) and long service life of
the backlighting
Can be used all over the world:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
- Up to 5 languages can be switched online
- Language-dependent texts and graphics
Graphics library available with off-the-shelf picture objects
Standard hardware and software interfaces for increasing
flexibility:
- Optional Multi Media Card, can be used for recipe data sets
and for backup of configuration/system data
Integrated printer port (USB)
■ Application
The OP 77B Operator Panels can be used wherever direct
operator control and monitoring of machines and installations is
required locally – whether in production automation, process
automation or building automation. They are in use in an
extensive range of sectors and applications.
Compatibility with OP7
• Same installation cutout as OP7
• The OP7 configurations can be loaded from ProTool/Lite,
ProTool and ProTool/Pro
Migration manual with description of the important differences
over OP7 or ProTool
■ Design
• 4.5" LC display, 160 x 64 pixels, monochromatic
• 23 system keys, 8 freely-configurable and freely-inscribable
function keys (4 with LEDs)
• Numeric and alphanumeric input options
• Compact design with low mounting depth
• Rugged plastic enclosure
• The front is resistant to various oils, greases and standard
detergents
• Plug-in terminals for 24 V DC power supply
• Interfaces:
- RS 485/422 interface for process connections (MPI,
PROFIBUS DP up to 12 Mbit/s)
- RS 232 interface for process connections
- USB printer interface
• Slot for Multi Media Card
2/80
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77B
■ Function
• Permanent window and template concept for creating screen
templates
• Input/output fields
for displaying and changing process parameters
• Function keys
for directly actuating functions and actions. Up to 16 functions
can be configured simultaneously on function keys. They can
be used directly as PROFIBUS DP input peripherals.
• Graphics
can be used as icons instead of text to "label" function keys or
buttons. They can also be used as simple on-screen graphics.
In the configuration tool, a library is available containing an
extensive range of graphics and a wide variety of objects. All
editors with an OLE interface can be used as graphics editors
(such as PaintShop, Designer or CorelDraw).
• Predefined texts
for labeling function keys, process images and process
values in any character size
• Bars are used for the graphical display of dynamic values
• Display selection from the PLC
supports operator prompting from the PLC
• Language selection during runtime
- 5 online languages, 32 configuration languages incl. Asian
and Cyrillic character sets
- Language-dependent texts and graphics
• User administration (security) according to the requirements
of the various sectors
- Authentication with user ID and password
- User-group-specific rights
• Signalling system
- Analog alarms
- Bit messages as well as the Alarm S message frame
procedure for SIMATIC S7
- Freely definable message classes (e.g. status/fault
messages) for definition of acknowledgment response
and display of message events
- Message history
• Recipe management
- With additional data storage (on optional multi-media card)
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Help texts
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Indicator light
for machine and plant status indication
• Scheduler (timer) for cyclic function execution
• Print
hard copy, messages and user-configurable reports
• Template concept
Picture elements configured in the template appear in every
picture
• User-friendly maintenance and configuration thanks to:
- Backup and restoring of the configuration, operating system,
data records and firmware on the optional Multi Media Card
- Backup and restoration of the configuration, operating
system, data records and firmware on a PC using ProSave
- Configuration download/upload via MPI/PROFIBUS DP/
RS 232/USB
- Automatic transfer identification
- Individual contrast settings
- Configuration simulation directly on the configuration
computer
- No batteries are necessary
Configuration
SIMATIC WinCC flexible Compact, Standard or Advanced
configuration software Version 2004 and higher is used for
configuration.
For more information about engineering software, see HMI software/engineering software SIMATIC WinCC flexible.
■ Integration
The OP 77B can be connected to:
• SIMATIC S7-200/-300/-400
• SIMATIC WinAC Software/Slot PLC
• SIMATIC S5
• SIMATIC 505
• Non-Siemens PLCs:
- Allen Bradley
- Mitsubishi
- LG GLOFA GM
- Modicon
- GE Fanuc
- Omron
Note:
Further information can be found under "System interfaces".
Siemens ST 80 · 2009
2/81
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77B
■ Technical specifications
OP 77B
Supply voltage
2
OP 77B
Type of output
Supply voltage
24 V DC
LED colors
permissible range
+20.4 V to +28.8 V DC
Interfaces
Rated current
0.2 A
Interfaces
1 x RS232, 1 x RS422, 1 x RS485
(max. 12 Mbit/s)
Multi Media Card slot
1 x Multi Media Card slot
USB
1 x USB
Ethernet
No
Memory
Type of storage
Type
Flash / RAM
Memory usable for project
data/Options
1000 KB usable memory for user
data
Operating systems
Operating system
Time
Clock
Green
Windows CE
Processor
• Type
Software clock, not battery backed
Configuration
Configuration tool
WinCC flexible Compact Version
2004 or higher (to be ordered
separately)
Display
Processor
ARM
Functionality under
WinCC flexible
Task planner
Yes
Help system
Yes
Message system
Display type
STN, Black/white
Size
4.5"
Resolution (W x H in pixel)
160 x 64
MTBF backlighting (at 25 °C)
about 100,000 hours
• Number of messages
1 000
• Bit messages
Yes
• Analog messages
Yes
• Message buffer
Ring buffer (n x 256 entries),
non-retentive
Operating mode
Operating elements
Membrane keyboard
Recipes
Function keys, programmable
8 function keys, 4 with LEDs
• Recipes
100
System keys
23
• Data records per recipe
200
Numeric/alphabetical input
Yes / Yes
• Entries per data record
200
Connection for mouse/keyboard/barcode reader
-/-/-
• Recipe memory
32 kByte integrated Flash,
expandable
Number of process images
Ambient conditions
Mounting position
Vertical
+/- 80°
maximum permissible angle of
incliniation without external ventilation
max. relative humidity (in %)
90%
• Process images
500
• Variables
1 000
• Limit values
Yes
• Multiplexing
Yes
Image elements
Temperature
0 °C to +50 °C
• Text objects
2,500 text elements
• Operation (max. tilt angle)
0 °C to +40 °C
• Graphics object
Bit maps, icons, icon
(full-screen)
• Transport, storage
-20 °C to +60 °C
• dynamic objects
Bar graphs
• Operation (vertical installation)
Degree of protection
Front
Lists
IP65, NEMA 4x, NEMA 12
(when installed)
• Text lists
300
IP20
• Graphics list
0
Certifications & Standards
• Libraries
Yes
Certifications
Security
Rear
CE, GL, ABS, BV, DNV, LRS, FM
Class I Div. 2, UL, CSA, cULus,
EX-Zone 2 (available soon),
EX-Zone 22 (available soon),
C-TICK, NEMA 4x, NEMA 12
I/O Options
I/O devices
2/82
Printer
Siemens ST 80 · 2009
• Number of user groups
50
• Passwords exportable
Yes
• Number of user rights
32
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77B
■ Technical specifications (continued)
OP 77B
Data medium support
Yes
• Recording/Printing
Alarms, report (shift report),
hardcopy
• Printer driver
ESC/P2, PCL3/PCL6
Fonts
US American (English)
Languages
• Online languages
5
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
Tahoma, WinCC flexible Standard,
symbol languages, all freely scalable
Transfer (Upload/Download)
• Transfer of configuration
MPI/PROFIBUS DP, serial, USB,
by means of external storage
medium, automatic transfer
recognition
Process coupling
• Connection to controller
S5, S7-200, S7-300/400, TI 505,
Win AC, Allen Bradley (DF1), Allen
Bradley (DF485), Mitsubishi (FX),
OMRON (LINK/Multilink), Modicon
(Modbus), for further non-Siemens
drivers, see section on "System
interfaces"
Expandability/openness
• Open Platform Program
Order No.
F
6AV6 641-0CA01-0AX01
OP 77B starter package
F
6AV6 651-1CA01-0AA0
No
Dimensions
• Operator Panel OP 77B
• SIMATIC WinCC flexible
Compact engineering software
• SIMATIC HMI Manual Collection
(DVD), 5 languages (English,
French, German, Italian,
Spanish)
• RS 232 cable (5 m)
• MPI cable (5 m)
• Voucher for Software Update
Service for 1 year
Configuration
see Chapter 4
with SIMATIC WinCC flexible
Configuration set
D
6AV6 621-0AA01-0AA0
Consisting of:
Engineering software SIMATIC
WinCC flexible Compact,
SIMATIC HMI Manual Collection
(DVD), 5 languages (English,
French, German, Italian and
Spanish),
USB/PPI cable Multimaster,
PC/PPI cable Multimaster,
MPI cable (5 m)
Documentation (to be ordered separately)
User Manual
WinCC flexible Compact/
Standard/Advanced
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
Front of enclosure (W x H)
150 mm x 186 mm
• Italian
6AV6 691-1AB01-3AD0
Mounting cutout/Device depth
(W x H/D) in mm
135 mm x 171 mm / 38.5 mm
device depth
• Spanish
6AV6 691-1AB01-3AE0
User Manual
WinCC flexible Communication
Weight
Weight
2
Consisting of:
Recording
• Keyboard fonts
SIMATIC OP 77B
Operator Panel with 4.5" display,
monochrome, incl. mounting
accessories
Functionality under
WinCC flexible (continued)
• Multi Media Card
■ Ordering data
0.5 kg
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
Accessories
Accessories for supplementary
ordering
See HMI Accessories
B) Subject to export regulations: AL: N and ECCN: EAR99S
D) Subject to export regulations: AL: N and ECCN: 5D992B1
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
Siemens ST 80 · 2009
2/83
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 70 series
SIMATIC OP 77B
■ Dimensions
■ More information
Additional information is available in the Internet under:
All specifications in mm. Tolerance ± 1 mm.
http://www.siemens.com/panels
2
150
38,5
Note:
134
6,2
2/84
Siemens ST 80 · 2009
G_ST80_XX_00087
170
186
Do you need a specific modification or option for the products
described here? Then look up "customer-specific products",
where you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177A
■ Overview
■ Application
The TP 177A Touch Panels can be used wherever direct operator control and monitoring of small machines and installations
is required locally – whether in production automation, process
automation or building automation. They are in use in an
extensive range of sectors and applications.
With its quick response times, the TP 177A is also ideally suited
to jog mode.
Compatible to TP 170A
• Installation cutout identical to TP 170A
• The TP 170A configurations can be loaded from ProTool/Lite,
ProTool and ProTool/Pro
• Migration manual with descriptions of the main differences
over TP 170A or ProTool
■ Design
• Touch Panel for operator control and monitoring of small
machines and plants
• Low-cost entry-level product in the category of touch panels
with graphics capability and all the basic functions required
for simple tasks
• Pixel graphics 5.7" STN touch screen (analog/resistive),
Bluemode (4 levels)
• All interfaces (e.g. MPI, PROFIBUS DP) are on board
• SIMATIC TP 177A is the innovative successor of Touch Panel
TP 170A
■ Benefits
• Can also be used in a vertical position where installation
space is restricted
• Integral component of Totally Integrated Automation (TIA):
Increased productivity, minimum engineering overhead,
reduction in life-cycle costs
• Reduction of service and commissioning costs through:
- Maintenance-free design (no battery) and long service life of
the backlit display
• Graphics library available with off-the-shelf picture objects
• Can be used worldwide:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
- You can switch between up to 5 languages online
- Language-dependent texts and graphics
• 5.7" STN, CCFL1)-backlit display, Bluemode (4 shades of blue)
• Analog resistive Touch
• Numerical system keyboard for decimal, binary and
hexadecimal number formats
• OnScreen alphabetic keyboard
• Compact design with low mounting depth
• Robust plastic housing
• The front is resistant to various oils, greases and standard
detergents
• Plug-in terminals for 24 V DC power supply
• RS 485 interface for process connections (MPI, PROFIBUS DP
up to 1.5 Mbit/s) and for the configuration download
1)
Cold Cathode Fluorescence Lamps
■ Function
• Templates concept for the creation of screen templates
• Input/output fields
for displaying and changing process parameters
• Buttons
are used for directly actuating functions and actions. Up to 16
functions can be configured simultaneously on buttons.
• Graphics
can be used as icons instead of text to "label" function keys or
buttons. They can also be used as background displays
(wallpaper).
In the configuration tool, a library is available containing extensive graphics and a wide variety of objects. All editors with an
OLE interface can be used as graphics editors, e.g.
PaintShop, Designer or CorelDraw, etc.
• Vector graphics
Simple geometric basic forms (line, circle and rectangle) can
be created direct in the configuring tool
• Predefined
for labeling function keys, process screens and process
values in different font sizes
• Curve functions and bars
are used for the display of dynamic values in graphics-based
format
• Language selection:
- 5 online languages, 32 configuration languages incl. Asian
and Cyrillic character sets
- Language-dependent texts and graphics
Siemens ST 80 · 2009
2/85
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177A
■ Function (continued)
2
• User administration (security) according to the requirements
of the various sectors
- Authentication with user ID and password
- User-group-specific rights
• Signaling system
- Discrete alarms
- Analog alarms
- Freely-definable message classes (e.g. status/fault
messages) for definition of acknowledgment response and
display of alarm events
- Message history
• Recipe management
• Help texts
for process images, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Indicator light
for machine and plant status indication
• Scheduler for cyclic function execution
• Template concept
Creation of picture templates (display elements configured in
the template appear in every image)
• Simple maintenance and configuration thanks to:
- Backup and restoration of configuration, operating system
and firmware on a PC using ProSave
- Configuration download via MPI/PROFIBUS DP and serially
via RS485
- Automatic transfer identification
- Individual contrast setting and calibration
- Clean screen
- No batteries are necessary
Configuration
SIMATIC WinCC flexible Compact, Standard or Advanced
engineering software Version 2004 SP1 and higher plus HSP is
used for configuration.
■ Technical specifications
TP 177A
Supply voltage
Supply voltage
24 V DC
permissible range
+20.4 V to +28.8 V DC
Rated current
0.24 A
Memory
Type of storage
Type
Flash / RAM
Memory usable for project
data/Options
512 KB usable memory for
user data
Time
Clock
• Type
Software clock, not battery backed
Configuration
Configuration tool
WinCC flexible Compact Version
2004 SP1 or higher (to be ordered
separately)
Display
Display type
STN, 4 shades of blue
Size
5.7"
Resolution (WxH in pixel)
320 x 240
MTBF backlighting (at 25 °C)
about 50,000 hours
Operating mode
Operating elements
Touch screen
Touchscreen
analog, resistive
Numeric/alphabetical input
Yes / Yes
Connection for mouse/keyboard/barcode reader
-/-/-
Ambient conditions
Mounting position
Vertical
Projects created with ProTool can be transferred to WinCC
flexible.
+/- 35°
Maximum permissible angle of
incliniation without external ventilation
For more information about engineering software, see HMI
software/engineering software SIMATIC WinCC flexible.
Max. relative humidity (in %)
■ Integration
The TP 177A can be connected to:
• SIMATIC S7-200/-300-400
• SIMATIC WinAC Software/Slot PLC
Note:
• Operation (vertical installation)
0 °C to +50 °C
• Operation (max. tilt angle)
0 °C to +40 °C
• Transport, storage
-20 °C to +60 °C
Degree of protection
Front
IP65, NEMA 4x, (when installed)
Rear
IP20
Certifications & Standards
For further information see "System interfaces"
2/86
90%
Temperature
Siemens ST 80 · 2009
Certifications
CE, GL, ABS, BV, DNV, LRS, FM
Class I Div. 2, UL, CSA, cULus,
EX-Zone 2 (available soon), EXZone 22 (available soon), C-TICK,
NEMA 4x
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177A
■ Technical specifications (continued)
TP 177A
Type of output
LED colors
None
1 x RS422, 1 x RS485
(max. 1.5 Mbit/s)
Slots
• Text lists
300
• Graphics list
100
• Libraries
Yes
PC card slot
No
CF card slot
No
• Number of user groups
50
Multi Media Card slot
No
• Passwords exportable
Yes
USB
No
• Number of user rights
32
Ethernet
No
Data medium support
• PC card
No
LINUX
• CF card
No
• Multi Media Card
No
Operating systems
Operating system
Processor
Processor
2
Lists
Interfaces
Interfaces
TP 177A
Functionality under
WinCC flexible (continued)
ARM
Security
Fonts
• Keyboard fonts
Functionality under
WinCC flexible
US American (English)
Languages
Number of Visual Basic scripts
Not possible
Task planner
Yes
Help system
Yes
Status/control
Not possible
Message system
• Number of messages
1 000
• Bit messages
Yes
• Analog messages
Yes
• Message buffer
Ring buffer (n x 256 entries), nonretentive
Recipes
• Online languages
5
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
Tahoma, WinCC flexible Standard,
symbol languages, 1 additional
character set can be loaded
Transfer (Upload/Download)
• Transfer of configuration
MPI/PROFIBUS DP, serial,
automatic transfer recognition
Process coupling
• Connection to controller
S7-200, S7-300/400, Win AC see
section on "System interfaces"
• Recipes
5
• Data records per recipe
20
• Entries per data record
20
• Open Platform Program
• Recipe memory
32 kByte integrated Flash
Dimensions
Front of enclosure (W x H)
212 mm x 156 mm
• Process images
250
• Variables
500
Mounting cutout/Device depth
(W x H/D) in mm
198 mm x 142 mm / 44 mm device
depth
• Limit values
Yes
Weights
• Multiplexing
Yes
Weight
Number of process images
Expandability/openness
No
0.75 kg
Image elements
• Text objects
1,000 text elements
• Graphics object
Bit maps, icons, icon (full-screen),
vector graphics
• Dynamic objects
Diagrams, bar graphs
Siemens ST 80 · 2009
2/87
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177A
■ Ordering data
SIMATIC TP 177A
6AV6 642-0AA11-0AX1
D
6AV6 651-2AA01-0AA0
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
Touch Panel with 5.7" STN
display, blue mode (4 levels),
incl. mounting accessories
TP 177A starter kit
44
212
Consisting of:
6,2
• Touch Panel TP 177A
G_ST80_XX_00143
• SIMATIC HMI Manual Collection
(DVD),
5 languages (English, French,
German, Italian, Spanish),
comprising: all currently
available user manuals,
manuals and communication
manuals for SIMATIC HMI
140
• SIMATIC WinCC flexible
Compact engineering software
156
2
Order No.
C
• MPI cable (5 m)
(for download and test purposes
only)
• RS 232/PPI multi-master cable
(for download and image
booting)
■ More information
Additional information is available in the Internet under:
• Software Update Service
for 1 year
http://www.siemens.companels
Configuration
• with SIMATIC WinCC flexible
see Chapter 4
Documentation (to be ordered separately)
Operating Instructions
TP 177A, TP 177B, OP 177B
• German
6AV6 691-1DG01-0AA1
• English
6AV6 691-1DG01-0AB1
• French
6AV6 691-1DG01-0AC1
• Italian
6AV6 691-1DG01-0AD1
• Spanish
6AV6 691-1DG01-0AE1
User Manual
WinCC flexible Compact/
Standard/Advanced
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
User Manual
WinCC flexible Communication
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation, on DVD
5 languages (English, French, German, Italian and Spanish); contains:
all currently available user manuals,
manuals and communication
manuals for SIMATIC HMI
Accessories
Accessories for supplementary
ordering
See HMI Accessories
B) Subject to export regulations: AL: N and ECCN: EAR99S
C) Subject to export regulations: AL: N and ECCN: EAR99T
D) Subject to export regulations: AL: N and ECCN: 5D992B1
2/88
Siemens ST 80 · 2009
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177B (incl. INOX)
■ Overview
• Touch Panel with comprehensive functions for operator
control and monitoring of machines and plants
• Pixel-graphics display with analog touch screen
- 4.3" TFT widescreen color display or
- 5.7" STN blue mode/color display
• All interfaces for communication with Siemens SIMATIC S7
(e.g. MPI, PROFIBUS DP) are on-board
• The PROFINET interface is on-board in the color version
• Drivers are also available for non-Siemens PLCs
• Content of message buffer is retained even when panel is
disconnected without batteries
• The 4" version features 4 additional function keys for optimized
operator control efficiency
• The SIMATIC TP 177B 6" is the innovative successor to the
TP 170B Touch Panel
• The TP 177B PN/DP is also available with a stainless steel front
(DIN EN 1672-2). The stainless steel front is appropriate e.g.
for the increased demands of the food and beverages
industry
■ Benefits
• Reduction of service and commissioning costs through:
- Backup/restore via a process interface or optionally via a
Multi Media Card (also possible using a USB stick on
4" panel)
- Image and configuration download via all device interfaces
- Maintenance-free structure and long service life of the
backlighting
The data in the message buffer are retained even when the
panel is disconnected from the supply, without battery
backup.
• Can be used worldwide:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
- Online language can be selected directly on the device
• Graphics library available with off-the-shelf picture objects
• Standard interfaces for increasing the flexibility:
- external Multi Media Card, used for recipe data sets and for
backup of configuration/system data (on the 4" panel, this is
also possible using a USB stick)
• Integrated USB interface for connecting, for example,
standard printers
• Simple engineering supported by comprehensive documentation on the SIMATIC HMI Manual Collection DVD
• Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes engineering outlay, reduces
lifecycle costs
• The panel versions with stainless steel front can be optimally
used in the food and beverages and pharmaceutical
industries. The front panels are designed for easy cleaning
and disinfecting. Liquids flow off automatically from the front
panels. In addition, the stainless steel front (including gasket)
provides protection against contamination by foods.
■ Application
Thanks to their practical functions and large user memory,
TP 177B Touch Panels can be used wherever operator control
and monitoring of machines and plants is necessary on site –
whether in production automation, process automation or building-services automation. The TP 177B is available in two display
sizes:
4.3" TFT widescreen display with 256 colors or
5.7" STN display with 256 colors or 4 shades of blue. The 4" version features four additional function keys for optimized operator
control efficiency. The color versions with integrated PROFINET
I/O interface can be implemented with even greater flexibility. A
USB interface is standard on all model types. A further highlight
is the non-volatile message buffer included as standard that
stores messages permanently without battery backup.
The TP 177B PN/DP with stainless steel front has been designed
for all industries requiring such. The front can be disinfected,
and does not affect the quality e.g. of foods (assuming regular
cleaning). Cleaning can be carried out using pressurized water
with a jet of 100 l/min at 1 bar from a distance of 2.5 to 3 m.
Liquids flow off automatically from the front panels.
Siemens ST 80 · 2009
2/89
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177B (incl. INOX)
■ Design
2
• Display versions
- 4.3" TFT widescreen display with 256 colors or
- 5.7" STN display with 256 colors or 4 shades of blue
• LED or CCFL1) Backlighting with long service life
• Analog resistive touch screen
• Numeric and alphanumeric on-screen keyboard
• High performance thanks to RISC processor and 2 MB user
memory, plus additional integrated recipe memory
• Data in the message buffer are retained even when panel is
disconnected from the power supply, without batteries
• MPI, PROFIBUS DP interfaces (up to 12 MBaud) as well as
USB 1.1 (max. 100 mA) on-board
• PROFINET interface is already on-board in the color versions
• Configuration of the 6" version with SIMATIC WinCC flexible
2005 Compact or higher, the 4" version as of WinCC flexible
2008 Compact
• Complete functionality for demanding tasks
• Comprehensive Reichert graphics library
• Multi Media Card slot, can be used for standard MMCs (for
backing up/restoring recipe data sets, the configuration and
system data)
• The 4" version also supports SD cards and USB sticks in
addition to Multi Media Cards
• Options for SINUMERIK, [email protected] and [email protected]
can be used
• Service-friendly thanks to maintenance-free design and long
service life of the backlighting display
1)
Cold Cathode Fluorescence Lamps
Configuration
■ Function
• Permanent window and template concept for creating screen
templates
• Input/output fields
for visualizing and editing process parameters
• Configurable buttons
with up to 16 functions are also used to directly trigger functions and actions
• Indicator light
for machine and plant status indication
• Predefined texts
for labeling function keys, process images and process values in any character size
• Help texts
for process images, messages and variables
• Vector graphics, graphics
can be used as icons instead of text for "labeling" buttons.
They can also be used as full-screen background pictures.
In the configuration tool, a library is available containing extensive graphics and a wide variety of objects. All editors with an
OLE interface (e.g., PaintShop, Designer or CorelDraw) can
be used as graphics editors.
• Curve functions and bars
are used for the display of dynamic values in graphics-based
format
• Dynamic positioning of objects and dynamic showing/hiding
of objects
• Arithmetic functions, limit value monitoring
for reliable process control with inputs and outputs
2/90
• Online language selection (16 selectable languages),
incl. Asian and Cyrillic languages,
this also applies to language-specific graphics
• Scheduler
for cyclic function execution
• Password protection (security)
User management – Authentication by means of user ID and
password, plus privileges specific to user groups, which is an
integral part of SIMATIC
• Signaling system
Freely definable message classes (acknowledgement
behavior and display can be configured) Administration of
status, fault and system messages. The alarm history is
retained even if the device is switched off. Analog alarms
(limit value messages) in addition to discrete alarms.
• Recipe management:
- With additional data storage (on ext. storage medium)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Multi Media Card slot
for external standard data carriers, can be used for
backup/restoration or for transporting recipe data records;
the 4" version also supports SD cards and USB sticks
• User-friendly maintenance and configuration thanks to:
- Backup and restoration of the configuration, operating
system, data records and firmware on a PC using ProSave
- Option to download/upload the configuration via all device
interfaces (with automatic transfer detection)
- Individual contrast and brightness setting and calibration
- Configuration simulation directly on the configuration
computer
Siemens ST 80 · 2009
Configuration is implemented using the innovative engineering
tool SIMATIC WinCC flexible 2005 for the 6" versions or WinCC
flexible 2008 for the 4" version, in each case the Compact Edition
or higher. SIMATIC WinCC flexible is the logical further development of the field-proven ProTool family. Projects generated using
ProTool can be easily migrated to WinCC. When OP17 projects
are implemented, the project engineer must make certain
changes following conversion as a result of the innovated display technology. Support is however provided by WinCC
flexible. If WinCC flexible is started directly from SIMATIC
Manager, data in STEP 7 can be accessed directly when the
panel is configured. Duplicated data input and data management is, therefore, avoided.
Additional options
• SINUMERIK
Optionally with "SINUMERIK HMI copy license WinCC flexible
CE". The SINUMERIK HMI engineering WinCC flexible
package is also required for configuration.
For further information see Catalog NC 60.
• [email protected] Service
Remote operator control and monitoring of SIMATIC HMI
systems based on TCP/IP networks
• [email protected] Access
Communication between HMI systems based on TCP/IP networks. Remote access to recipe data sets, passwords and
information specific to the HMI system, and much more.
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177B (incl. INOX)
■ Technical specifications
SIMATIC TP 177B
widescreen
SIMATIC TP 177B
bluemode
SIMATIC TP 177B
color
SIMATIC TP 177B
color INOX
Supply voltage
24 V DC
24 V DC
24 V DC
24 V DC
permissible range
+20.4 V to +28.8 V DC
+20.4 V to +28.8 V DC
+20.4 V to +28.8 V DC
+18 V to +30 V DC
Rated current
0.2 A
0.24 A
0.24 A
0.24 A
Type
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Memory usable for project
data/Options
2048 KB usable memory
for user data
2048 KB usable memory
for user data
2048 KB usable memory
for user data
2048 KB usable memory
for user data
Supply voltage
2
Memory
Type of storage
Time
Clock
• Type
Hardware clock, Synchroni- Hardware clock, Synchroni- Hardware clock, Synchroni- Hardware clock, Synchronizable, not battery backed
zable, not battery backed
zable, not battery backed
zable, not battery backed
Protocols
Protocols (terminal link)
• [email protected]
Yes
Configuration
Configuration tool
WinCC flexible Compact
Version 2008 or higher
(to be ordered separately)
WinCC flexible Compact
Version 2005 or higher
(to be ordered separately)
WinCC flexible Compact
Version 2005 or higher
(to be ordered separately)
WinCC flexible Compact
Version 2005 or higher
(to be ordered separately)
Display
Display type
TFT, 256 Colors
STN, 4 shades of blue
STN, 256 Colors
STN, 256 Colors
Size
4.3" (95 mm x 53 mm)
5.7" (120 mm x 90 mm)
5.7" (120 mm x 90 mm)
5.7" (120 mm x 90 mm)
Resolution (W x H in pixel)
480 x 272
320 x 240
320 x 240
320 x 240
MTBF backlighting
(at 25 °C)
about 30,000
about 50,000 hours
about 50,000 hours
about 50,000 hours
Operating mode
Operating elements
Membrane keyboard
Touch screen
Touch screen
Touch screen
Touchscreen
analog, resistive
analog, resistive
analog, resistive
analog, resistive
Numeric/alphabetical input
Yes (on-screen keyboard) /
Yes (on-screen keyboard)
Yes / Yes
Yes / Yes
Yes / Yes
Connection for mouse/
keyboard/barcode reader
USB / USB / -
USB / USB / -
USB / USB / -
USB / USB / -
Mounting position
Vertical
Vertical
Vertical
Vertical
maximum permissible
angle of incliniation without
external ventilation
+/- 35°
+/- 35°
+/- 35°
+/- 35°
max. relative humidity
(in %)
90%
90%
90%
90%
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
• Operation (max. tilt angle) 0 °C to +40 °C
Ambient conditions
Temperature
• Operation (vertical
installation)
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Front
IP65, NEMA 4, NEMA 4x,
NEMA 12 (when installed)
IP65, NEMA 4x, NEMA 12
(when installed)
IP65, NEMA 4x, NEMA 12
(when installed)
IP66K, NEMA 4, NEMA 4x,
NEMA 12 (when installed)
Rear
IP20
IP20
IP20
IP20
• Transport, storage
Degree of protection
Siemens ST 80 · 2009
2/91
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177B (incl. INOX)
■ Technical specifications (continued)
2
SIMATIC TP 177B
widescreen
SIMATIC TP 177B
bluemode
SIMATIC TP 177B
color
SIMATIC TP 177B
color INOX
CE, cULus, C-TICK,
NEMA4, NEMA 4x,
NEMA 12
available soon:
GL, ABS, BV, DNV, LRS, FM
Class I Div. 2, UL, CSA
CE, GL, ABS, BV, DNV, LRS,
FM Class I Div. 2, UL, CSA,
cULus, EX-Zone 2 (available
soon), EX-Zone 22
(available soon), C-TICK,
NEMA 4x, NEMA 12
CE, GL, ABS, BV, DNV, LRS,
FM Class I Div. 2, UL, CSA,
cULus, EX-Zone 2 (available
soon), EX-Zone 22
(available soon), C-TICK,
NEMA 4x, NEMA 12
CE, GL, ABS, BV, DNV, LRS,
PRS, FM Class I Div. 2, UL,
CSA, cULus, EX-Zone 2/22,
Gost-R, C-TICK, NEMA 4,
NEMA 4x, NEMA 12
Printer
Printer
Printer
Printer
Interfaces
RS232 optional, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)
RS232 optional, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)
RS232 optional, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)
RS232 optional, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)
USB
1 x USB
1 x USB
1 x USB
1 x USB
Ethernet
1 x Ethernet (RJ45)
No
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
Certifications & Standards
Certifications
I/O Options
I/O devices
Interfaces
Slots
PC card slot
No
No
No
No
CF card slot
No
No
No
No
Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
1 x Multi Media Card slot
Windows CE (Version 5)
Windows CE
Windows CE
Windows CE
RISC 32-bit, 266 MHz
ARM, 200 MHz
ARM, 200 MHz
ARM, 200 MHz
Applications/options
[email protected],
[email protected]
[email protected],
[email protected]
[email protected],
[email protected]
[email protected],
[email protected]
Number of Visual Basic
scripts
Not possible
Operating systems
Operating system
Processor
Processor
Functionality under
WinCC flexible
Task planner
Yes
Yes
Yes
Yes
Help system
Yes
Yes
Yes
Yes
Status/control
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
Message system
• Number of messages
2 000
2 000
2 000
2 000
• Bit messages
Yes
Yes
Yes
Yes
• Analog messages
Yes
Yes
Yes
Yes
• Message buffer
Ring buffer (n x 256 entries), Ring buffer (n x 256 entries), Ring buffer (n x 256 entries), Ring buffer (n x 256 entries),
retentive, maintenance-free retentive, maintenance-free retentive, maintenance-free retentive, maintenance-free
Recipes
• Recipes
100
100
100
100
• Data records per recipe
200
200
200
200
• Entries per data record
200
200
200
200
• Recipe memory
32 kByte integrated Flash,
expandable
32 kByte integrated Flash,
expandable
32 kByte integrated Flash,
expandable
32 kByte integrated Flash,
expandable
• Process images
500
500
500
500
• Variables
1 000
1 000
1 000
1 000
• Limit values
Yes
Yes
Yes
Yes
• Multiplexing
Yes
Yes
Yes
Yes
Number of process images
2/92
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177B (incl. INOX)
■ Technical specifications (continued)
SIMATIC TP 177B
widescreen
SIMATIC TP 177B
bluemode
SIMATIC TP 177B
color
SIMATIC TP 177B
color INOX
• Text objects
2,500 text elements
2,500 text elements
2,500 text elements
2,500 text elements
• Graphics object
Bit maps, icons, icon (fullscreen), vector graphics
Bit maps, icons, icon (fullscreen), vector graphics
Bit maps, icons, icon (fullscreen), vector graphics
Bit maps, icons, icon (fullscreen), vector graphics
• dynamic objects
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Functionality under
WinCC flexible (continued)
2
Image elements
Lists
• Text lists
300
300
300
300
• Graphics list
100
100
100
100
• Libraries
Yes
Yes
Yes
Yes
Security
• Number of user groups
50
50
50
50
• Passwords exportable
Yes
Yes
Yes
Yes
• Number of user rights
32
32
32
32
Data medium support
• PC card
No
No
No
No
• CF card
No
No
No
No
• Multi Media Card
Yes
Yes
Yes
Yes
Recording
• Recording/Printing
Alarms, report (shift report), Alarms, report (shift report), Alarms, report (shift report), Alarms, report (shift report),
color print, hardcopy
hardcopy
color print, hardcopy
color print, hardcopy
• Printer driver
ESC/P2, PCL3/PCL6
ESC/P2, PCL3/PCL6
ESC/P2, PCL3/PCL6
ESC/P2, PCL3/PCL6
US American (English)
US American (English)
US American (English)
US American (English)
Fonts
• Keyboard fonts
Languages
• Online languages
16
16
16
16
• Configuration languages
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK,
FIN, GR, J, KP / ROK, NL, N,
PL, P, RUS, S, CZ / SK, TR,
H
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK,
FIN, GR, J, KP / ROK, NL, N,
PL, P, RUS, S, CZ / SK, TR,
H
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK,
FIN, GR, J, KP / ROK, NL, N,
PL, P, RUS, S, CZ / SK, TR,
H
D, GB, F, I, E, CHN "traditional", CHN "simplified", DK,
FIN, GR, J, KP / ROK, NL, N,
PL, P, RUS, S, CZ / SK, TR,
H
• Fonts
Tahoma, Courier New,
WinCC flexible Standard,
symbol languages, 1 additional character sets can be
loaded, all freely scalable
Tahoma, Courier New,
WinCC flexible Standard,
symbol languages, 2 additional character sets can be
loaded, all freely scalable
Tahoma, Courier New,
WinCC flexible Standard,
symbol languages, 2 additional character sets can be
loaded, all freely scalable
Tahoma, Courier New,
WinCC flexible Standard,
symbol languages, 2 additional character sets can be
loaded, all freely scalable
MPI/PROFIBUS DP, USB,
Ethernet, by means of
external storage medium,
automatic transfer recognition
MPI/PROFIBUS DP, serial,
USB, by means of external
storage medium, automatic
transfer recognition
MPI/PROFIBUS DP, serial,
USB, Ethernet, by means of
external storage medium,
automatic transfer recognition
MPI/PROFIBUS DP, serial,
USB, Ethernet, by means of
external storage medium,
automatic transfer recognition
S5, S7-200, S7-300/400,
WinAC, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Mitsubishi (FX),
Telemecanique (ADJUST),
Modicon (Modbus), for
further non-Siemens drivers,
see "System interfaces"
S5, S7-200, S7-300/400,
Win AC, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Mitsubishi (FX),
Telemecanique (ADJUST),
Modicon (Modbus), for
further non-Siemens drivers,
see "System interfaces"
S5, S7-200, S7-300/400,
Win AC, PC (TCP/IP),
SINUMERIK, SIMOTION,
Allen Bradley (DF1),
Mitsubishi (FX),
Telemecanique (ADJUST),
Modicon (Modbus), for
further non-Siemens drivers,
see "System interfaces"
S5, S7-200, S7-300/400,
Win AC, PC (TCP/IP),
SINUMERIK, SIMOTION,
Allen Bradley (DF1),
Mitsubishi (FX), Telemecanique (ADJUST),
Modicon (Modbus), for
further non-Siemens drivers,
see "System interfaces"
No
Yes
Yes
Yes
Front of enclosure (W x H)
140 mm x 116 mm
212 mm x 156 mm
212 mm x 156 mm
212 mm x 156 mm
Mounting cutout/Device
depth (W x H/D)
123 mm x 99 mm/48 mm
198 mm x 142 mm / 44 mm
device depth
198 mm x 142 mm / 44 mm
device depth
198 mm x 142 mm / 46 mm
device depth
0.5 kg
0.8 kg
0.8 kg
0.9 kg
Transfer (Upload/Download)
• Transfer of configuration
Process coupling
• Connection to controller
Expandability/openness
• Open Platform Program
Dimensions
Weights
Weight
Siemens ST 80 · 2009
2/93
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177B (incl. INOX)
■ Ordering data
Order No.
SIMATIC TP 177B
Touch Panel with
2
Order No.
Configuration software
• with SIMATIC WinCC flexible
• 4.3" TFT widescreen color
display (256 colors)
6AV6 642-0BD01-3AX0
• 5.7" STN blue mode display
(4 levels)
F
6AV6 642-0BC01-1AX1
• 5.7" STN color display
(256 colors)
F
6AV6 642-0BA01-1AX1
• 5.7" STN color display
(256 colors) INOX with stainless
steel front
6AV6 642-8BA10-0AA1
incl. mounting accessories
TP 177B 4" starter kit
6AV6 652-2KA00-0AA0
Consisting of:
See Chapter 4
Configuration set
Consisting of:
SIMATIC WinCC flexible Compact
engineering software,
SIMATIC HMI Manual Collection
(DVD), 5 languages (English,
French, German, Italian and
Spanish), PC/PPI cable Multimaster, MPI cable (5 m) (for download
and test purposes only)
D
• with SIMATIC WinCC flexible
Compact engineering software
6AV6 621-0AA01-0AA0
Documentation (to be ordered separately)
Operating Instructions
TP 177micro/TP 177A/TP 177B/
OP 177B (WinCC flexible)
• TP 177B with 4.3" TFT
widescreen color display
(256 colors)
• German
6AV6 691-1DG01-0AA1
• English
6AV6 691-1DG01-0AB1
• SIMATIC HMI Manual Collection
(DVD), 5 languages (English,
French, German, Italian,
Spanish)
• French
6AV6 691-1DG01-0AC1
• Italian
6AV6 691-1DG01-0AD1
• Spanish
6AV6 691-1DG01-0AE1
• MPI cable (5 m) (for download
and test purposes only)
User Manual
WinCC flexible
Compact/Standard/Advanced
• SIMATIC WinCC flexible
Compact configuration software
• Software Update Service for
1 year
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
Consisting of:
• French
6AV6 691-1AB01-3AC0
• TP 177B with 5.7" STN color
display (256 colors)
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
TP 177B 6" starter kit
F
6AV6 551-2EA01-1AA0
• Configuration software SIMATIC
WinCC flexible Compact
• SIMATIC HMI Manual Collection
(DVD), 5 languages (English,
French, German, Italian,
Spanish)
• MPI cable (5 m) (for download
and test purposes only), PC/PPI
cable
• Software Update Service for
1 year
User Manual
WinCC flexible Communication
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and communication manuals for SIMATIC
HMI
Accessories
Accessories for supplementary
ordering
B) Subject to export regulations: AL: N and ECCN: EAR99S
D) Subject to export regulations: AL: N and ECCN: 5D992B1
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
2/94
Siemens ST 80 · 2009
See HMI Accessories
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC TP 177B (incl. INOX)
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
212
6,2
196
G_ST80_XX_00353
156
98
48
SIMATIC TP 177B, 4" version
50
SIMATIC TP 177B PN/DP INOX
■ More information
Additional information is available in the Internet under:
212
http://www.siemens.com/panels
6
196
44
G_ST80_XX_00293
140
156
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
SIMATIC TP 177B PN/DP and DP, 6" versions
Siemens ST 80 · 2009
2/95
G_ST80_XX_00315
122
116
2
3
140
140
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC OP 177B
■ Overview
■ Benefits
2
• Touch/Key Panel with comprehensive functions for operator
control and monitoring of machines and plants
• Content of message buffer is retained even when panel is
disconnected, without batteries
• Pixel-graphics STN blue-mode/color display with analog
touch screen and additional 32 function keys
• Interfaces for communication with Siemens SIMATIC S7
(e.g. MPI, PROFIBUS DP) are on-board
• Ethernet is on-board in the color version
• Drivers are also available for non-Siemens PLCs
• Installation compatible with OP17
2/96
Siemens ST 80 · 2009
• Reduction of service and commissioning costs through:
- Backup/restoration via a process interface or optionally via a
Multi Media Card
- Remote downloading of the configuration with automatic
transfer recognition via all device interfaces
- Maintenance-free design (no battery) and long service life of
the backlighting
- System keys that can be assigned to any function keys and
used as an alternative to or in parallel with the on-screen
keyboard
• Maintenance-free message buffer
• Can be used worldwide:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
- Online language can be selected directly on the device
• Language-dependent texts and graphics
• Graphics library available with off-the-shelf picture objects
• Standard interfaces for increasing the flexibility:
- External MMC, used for recipe data records and for backup
of configuration/system data
• Integrated USB interface for connecting, for example, standard printers
• Simple engineering supported by comprehensive documentation on the SIMATIC HMI Manual Collection DVD
• Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes engineering outlay, reduces
lifecycle costs
■ Application
Thanks to their practical functions and large user memory,
OP 177B Operator Panels can be used wherever operator control and monitoring of machines and plants is necessary on site
– whether in production automation, process automation or
building-services automation. The OP 177B panels are now
available with a 4-color blue-mode display or a 256-color STN
display. The color variant complete with an integral PROFINET
I/O interface can be implemented with even greater flexibility. A
USB port is standard on both model types. A further highlight is
the non-volatile message buffer included as standard that stores
messages permanently without battery backup.
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC OP 177B
■ Design
• 256 colors with color display or 4 blue-mode monochrome
STN display
• CCFL1) Backlighting with long service life
• Analog resistive touch screen and membrane keyboard with
32 function keys
• Numeric and alphanumeric on-screen keyboard
• High performance thanks to RISC processor and 2 MB user
memory, plus additional integrated recipe memory
• The data in the message buffer are retained even when panel
is disconnected from the power supply, without batteries
• MPI, PROFIBUS DP interfaces (up to 12 Mbaud) as well as
USB 1.1 (max. 100 mA) on-board
• Ethernet (PROFINET I/O-capable) with the color variant
• Integrated USB interface
• Can be configured using SIMATIC WinCC flexible 2005
Compact and higher
• Complete functionality for demanding tasks
• Comprehensive Reichert graphics library
• Multi Media Card slot, can be used for standard MMCs (for
backing up recipe data sets, the configuration and system
data)
• Remote downloading of the configuration via all interfaces
with automatic transfer recognition
• The SINUMERIK, [email protected] and [email protected] options
can be used
• Service-friendly thanks to maintenance-free design and long
service life of the backlighting display
1)
Cold Cathode Fluorescence Lamps
■ Function
• Permanent window and template concept for creating screen
templates
• Input/output fields
for visualizing and editing process parameters
• Configurable buttons
with up to 16 functions are also used to directly trigger
functions and actions
• Indicator light
for indicating machine and plant statuses
• Predefined texts
for labeling function keys, process images and process
values in any character size
• Help texts
for process screens, messages and variables
• Vector graphics, graphics
can be used as icons instead of text for "labeling" buttons.
They can also be used as full-screen background images.
The configuration tool contains a library with extensive
graphics and diverse objects. All editors with an OLE interface
can be used as graphics editors, e.g. PaintShop, Designer or
CorelDraw, etc.
• Curve functions and bars
are used for graphical display of dynamic values
• Dynamic positioning of objects and dynamic showing/hiding
of objects
• Arithmetic functions, limit value monitoring
for reliable process control with inputs and outputs
• Online language selection (16 selectable languages), incl.
Asian and Cyrillic languages
this also applies to language-specific graphics
• Scheduler
for cyclic function execution
• Password protection (security)
User management – Authentication by means of user ID and
password, plus privileges specific to user groups, which is an
integral part of SIMATIC
• Signaling system;
Freely definable message classes (acknowledgement behavior and display can be configured), administration of status,
fault and system alarms. The message history is retained even
if the device is switched off.
Analog alarms (limit value messages) in addition to bit
messages
• Recipe management
- With additional data storage (on ext. storage medium)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Multi Media Card (MMC) slot
for external standard data carrier, can be used for backup/
restoration or for transporting recipe data records
• User-friendly maintenance and configuration thanks to:
- backup and restoration of the configuration, operating
system, data records and firmware on a PC using ProSave
- Option to download/upload the configuration via all device
interfaces (with automatic transfer detection)
- Individual contrast setting and calibration
- Configuration simulation directly on the configuration
computer
Configuration
The equipment is configured using the innovative engineering
tool SIMATIC WinCC flexible 2005 (Compact and above).
SIMATIC WinCC flexible is the logical further development of the
field-proven ProTool family. Projects generated using ProTool
can be easily migrated to WinCC. When OP17 projects are
implemented, the project engineer must make certain changes
following conversion as a result of the innovated display
technology. Support is however provided by WinCC flexible.
OP 170B projects can be loaded problem-free because all
operator control actions can be performed using the on-screen
keyboard. If WinCC flexible is started directly from SIMATIC
Manager, data in STEP 7 can be accessed directly at the click of
a mouse button when the panel is configured. Duplicated
data input and data management is, therefore, avoided.
Additional options
• SINUMERIK
Optionally with "SINUMERIK HMI copy license WinCC flexible
CE". For configuration, a "SINUMERIK HMI engineering
package WinCC flexible" is also necessary.
For further information, see the NC 60 Catalog.
• [email protected] Service
Remote operator control and monitoring of SIMATIC HMI
systems based on TCP/IP networks
• [email protected] Access
Communication between HMI systems based on TCP/IP
networks. Remote access to recipe data sets, passwords and
information specific to the HMI system, and much more.
Siemens ST 80 · 2009
2/97
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC OP 177B
■ Technical specifications
2
OP 177B
bluemode
OP 177B
color
Supply voltage
24 V DC
24 V DC
permissible range
+20.4 V to
+28.8 V DC
+20.4 V to
+28.8 V DC
Rated current
0.24 A
0.24 A
Type
Flash / RAM
Flash / RAM
Memory usable for project
data/Options
2048 KB usable
memory for user
data
2048 KB usable
memory for user
data
Supply voltage
OP 177B
bluemode
OP 177B
color
CE, GL, ABS, BV,
DNV, LRS, FM
Class I Div. 2, UL,
CSA, cULus,
EX-Zone 2
(available soon),
EX-Zone 22
(available soon),
C-TICK, NEMA
4x, NEMA 12
CE, GL, ABS, BV,
DNV, LRS, FM
Class I Div. 2, UL,
CSA, cULus,
EX-Zone 2
(available soon),
EX-Zone 22
(available soon),
C-TICK, NEMA
4x, NEMA 12
Printer
Printer
Green
Green
Certifications & Standards
Certifications
Memory
Type of storage
I/O/Options
I/O devices
Type of output
Time
Clock
LED colors
• Type
Hardware clock,
Synchronizable,
not battery
backed
Hardware clock,
Synchronizable,
not battery
backed
Interfaces
Interfaces
RS232 optional,
1 x RS422,
1 x RS485
(max. 12 Mbit/s)
RS232 optional,
1 x RS422,
1 x RS485
(max. 12 Mbit/s)
WinCC flexible
Compact Version
2005 or higher
(to be ordered
separately)
WinCC flexible
Compact Version
2005 or higher
(to be ordered
separately)
USB
1 x USB
1 x USB
Ethernet
No
1 x Ethernet
(RJ45)
Configuration
Configuration tool
Display
Display type
STN, 4 shades of STN, 256 Colors
blue
Slots
PC card slot
No
No
CF card slot
No
No
Multi Media Card slot
1 x Multi Media
Card slot
1 x Multi Media
Card slot
Windows CE
Windows CE
ARM, 200 MHz
ARM, 200 MHz
Size
5.7" (120 mm x
90 mm)
5.7" (120 mm x
90 mm)
Resolution (W x H in pixel)
320 x 240
320 x 240
Operating system
MTBF backlighting
(at 25 °C)
about 50,000
hours
about 50,000
hours
Processor
Processor
Operating mode
Operating elements
Membrane keyboard
Function keys,
programmable
32 function keys, 32 function keys,
26 with LEDs
26 with LEDs
Touchscreen
analog, resistive
Numeric/alphabetical input
Operating systems
Yes / Yes
Connection for mouse/keyboard/ USB / USB / barcode reader
Membrane keyboard
analog, resistive
Yes / Yes
USB / USB / -
Functionality under WinCC
flexible
Applications/options
[email protected],
[email protected]
Task planner
Yes
Yes
Help system
Yes
Yes
Status/control
with SIMATIC S7
with SIMATIC S7
Message system
• Number of messages
2 000
2 000
Mounting position
Vertical
Vertical
• Bit messages
Yes
Yes
maximum permissible angle
of incliniation without external
ventilation
+/- 35°
+/- 35°
• Analog messages
Yes
Yes
• Message buffer
max. relative humidity (in %)
90%
Ring buffer
(n x 256 entries),
retentive, maintenance-free
Ring buffer
(n x 256 entries),
retentive, maintenance-free
Ambient conditions
90%
Temperature
• Operation (vertical installation) 0 °C to +50 °C
0 °C to +50 °C
0 °C to +40 °C
0 °C to +40 °C
• Operation (max. tilt angle)
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
Degree of protection
Front
IP65, NEMA 4x,
NEMA 12
(when installed)
IP65, NEMA 4x,
NEMA 12
(when installed)
Rear
IP20
IP20
2/98
Siemens ST 80 · 2009
Recipes
• Recipes
100
100
• Data records per recipe
200
200
• Entries per data record
200
200
• Recipe memory
32 kByte integrated Flash,
expandable
32 kByte integrated Flash,
expandable
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC OP 177B
■ Technical specifications (continued)
OP 177B
bluemode
OP 177B
color
OP 177B
bluemode
Functionality under WinCC
flexible (continued)
Functionality under WinCC
flexible (continued)
Number of process images
Languages
OP 177B
color
2
• Process images
500
500
• Online languages
16
16
• Variables
1 000
1 000
• Configuration languages
• Limit values
Yes
Yes
• Multiplexing
Yes
Yes
• Text objects
2,500 text
elements
2,500 text
elements
D, GB, F, I, E,
CHN "traditional",
CHN "simplified",
DK, FIN, GR, J,
KP / ROK, NL, N,
PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E,
CHN "traditional",
CHN "simplified",
DK, FIN, GR, J,
KP / ROK, NL, N,
PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
• Graphics object
Bit maps, icons, Bit maps, icons,
icon (full-screen), icon (full-screen),
vector graphics
vector graphics
• dynamic objects
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Tahoma, Courier
New, WinCC
flexible Standard, symbol languages, 2
additional character sets can be
loaded, all freely
scalable
Tahoma, Courier
New, WinCC
flexible Standard, symbol languages, 2
additional character sets can be
loaded, all freely
scalable
• Text lists
300
300
• Graphics list
100
100
• Libraries
Yes
Yes
MPI/PROFIBUS
DP, serial, USB,
by means of
external storage
medium, automatic transfer
recognition
MPI/PROFIBUS
DP, serial, USB,
Ethernet, by
means of external
storage medium,
automatic transfer recognition
S5, S7-200, S7300/400, Win AC,
SINUMERIK,
SIMOTION, Allen
Bradley (DF1),
Mitsubishi (FX),
Telemecanique
(ADJUST), Modicon (Modbus),
for further nonSiemens drivers,
see section on
"System interfaces"
S5, S7-200, S7300/400, Win AC,
PC (TCP/IP),
SINUMERIK,
SIMOTION, Allen
Bradley (DF1),
Mitsubishi (FX),
Telemecanique
(ADJUST), Modicon (Modbus),
for further nonSiemens drivers,
see section on
"System interfaces"
Yes
Yes
Front of enclosure (W x H)
243 mm x
212 mm
243 mm x
212 mm
Mounting cutout/Device depth
(W x H/D) in mm
229 mm x 196
mm / 45 mm
device depth
229 mm x 196
mm / 45 mm
device depth
1 kg
1 kg
Image elements
Lists
Transfer (Upload/Download)
• Transfer of configuration
Security
• Number of user groups
50
50
• Passwords exportable
Yes
Yes
Process coupling
• Number of user rights
32
32
• Connection to controller
Data medium support
• PC card
No
No
• CF card
No
No
• Multi Media Card
Yes
Yes
• Recording/Printing
Alarms, report
(shift report),
hardcopy
Alarms, report
(shift report),
color print,
hardcopy
• Printer driver
ESC/P2,
PCL3/PCL6
ESC/P2,
PCL3/PCL6
US American
(English)
US American
(English)
Recording
Fonts
• Keyboard fonts
Expandability/openness
• Open Platform Program
Dimensions
Weights
• Weight
Siemens ST 80 · 2009
2/99
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 170 series
SIMATIC OP 177B
B) Subject to export regulations: AL: N and ECCN: EAR99S
D) Subject to export regulations: AL: N and ECCN: 5D992B1
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
2/100
Siemens ST 80 · 2009
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
6,2
35,6
243
42
G_ST80_XX_00270
194
2
Order No.
SIMATIC OP 177B
Operator panel with 5.7" STN
display,
F 6AV6 642-0DC01-1AX1
• Blue mode (4 levels)
F 6AV6 642-0DA01-1AX1
• Color (256 colors)
incl. mounting accessories
F 6AV6 551-2HA01-1AA0
OP 177B starter kit
Consisting of:
• OP 177B with STN display, color
• Configuration software SIMATIC
WinCC flexible Compact
• SIMATIC HMI Manual Collection
(DVD), 5 languages (English,
French, German, Italian, Spanish)
• MPI cable (5 m) (for download
and test purposes only),
PC/PPI cable
• Software Update Service for 1 year
Configuring software
See HMI software
• with SIMATIC WinCC flexible
Compact
D 6AV6 621-0AA01-0AA0
Configuration set
Consisting of:
SIMATIC WinCC flexible Compact
engineering software, SIMATIC
HMI Manual Collection (DVD),
5 languages (En, Fr, Ger, It and
Sp), PC/PPI cable Multimaster,
MPI cable (5 m) (for download
and test purposes only)
Documentation (must be ordered separately)
Operating Instructions
TP 177micro/TP 177A/TP 177B/
OP 177B (WinCC flexible)
• German
6AV6 691-1DG01-0AA1
6AV6 691-1DG01-0AB1
• English
6AV6 691-1DG01-0AC1
• French
• Italian
6AV6 691-1DG01-0AD1
6AV6 691-1DG01-0AE1
• Spanish
User Manual WinCC flexible
Compact/Standard/Advanced
• German
6AV6 691-1AB01-3AA0
6AV6 691-1AB01-3AB0
• English
6AV6 691-1AB01-3AC0
• French
6AV6 691-1AB01-3AD0
• Italian
• Spanish
6AV6 691-1AB01-3AE0
User Manual
WinCC flexible Communication
• German
6AV6 691-1CA01-3AA0
6AV6 691-1CA01-3AB0
• English
6AV6 691-1CA01-3AC0
• French
6AV6 691-1CA01-3AD0
• Italian
6AV6 691-1CA01-3AE0
• Spanish
SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0
Electronic documentation, on DVD
5 languages (En, Fr, Ger, It and Sp);
contains: all currently available user
manuals, manuals and communication manuals for SIMATIC HMI
Accessories
see HMI accessories,
Accessories for supplementary
from page 2/158
ordering
212,5
■ Ordering data
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/panels
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC TP 277 6"
■ Overview
■ Application
Thanks to their practical functions and large user memory, the
TP 277 6" Touch Panels can be used wherever operator control
and monitoring of machines and plants is necessary on site –
whether in production automation, process automation or building-services automation. The TP 277 6" offers a 256-color TFT
display. The unit has an integral PROFINET I/O interface for even
greater flexibility. A further highlight is the non-volatile message
buffer included as standard that stores messages permanently
without battery backup.
■ Design
•
•
•
•
•
•
• Touch Panel with comprehensive functions for operator
control and monitoring of machines and plants
• Content of message buffer is retained even when panel is
disconnected, without batteries
• Pixel graphics TFT display with 256 colors and touchscreen
• Interfaces for communication with Siemens SIMATIC S7
(e.g. MPI, PROFIBUS DP) are on-board
• Ethernet on-board
• Use of scripts and archives
• Drivers are also available for non-Siemens PLCs
• Installation-compatible with TP 270 6" and MP 270B 6"
■ Benefits
• Reduction of service and commissioning costs through:
- Backup/restoration via a process interface or optionally via
a Multi Media Card
- Remote downloading of the configuration with automatic
transfer recognition via all device interfaces
- Maintenance-free design (no battery) and long service life of
the backlighting
• Maintenance-free message buffer
• Use of scripts and archives
• Can be used all over the world:
- 32 offline languages can be configured (incl. Asian and
Cyrillic character sets)
- 16 online languages can be selected directly on the device
• Graphics library available with off-the-shelf picture objects
• Standard interfaces for increasing the flexibility:
- External multimedia card, used for recipe data sets, archive
and for backup of configuration/system data
• Integrated USB interface for connecting, for example, standard printers
• Simple engineering supported by comprehensive documentation on the SIMATIC HMI Manual Collection DVD
• Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes engineering outlay, reduces
lifecycle costs
•
•
•
•
•
•
•
•
•
•
•
•
1)
256-color TFT display
CCFL1) Long-life backlighting
Analog resistive touch screen
Numeric and alphanumeric on-screen keyboard
Scripts and archives
High performance thanks to RISC processor and 4 MB user
memory, plus additional integrated recipe memory
The data in the message buffer is retained even when the
panel is disconnected from the supply, without battery backup
MPI, PROFIBUS DP interfaces (up to 12 Mbaud) as well as
USB 1.1 (max. 100 mA) on-board
Ethernet (PROFINET I/O capable)
Integral USB interface
Can be configured using SIMATIC WinCC flexible 2005
Standard SP1
Complete functionality for demanding tasks
Comprehensive Reichert graphics library
32 languages (e.g., Cyrillic, traditional Chinese, simplified
Chinese) and online switching between up to 16 languages
Multi Media Card slot, can be used for standard Multi Media
Cards (for backing up archives and recipe data sets, the
configuration and system data)
Remote downloading of the configuration via all interfaces
with automatic transfer recognition
Options for SINUMERIK, [email protected] and [email protected]
can be used
Service-friendly thanks to maintenance-free design and long
service life of the backlighting display
Cold Cathode Fluorescence Lamps
Siemens ST 80 · 2009
2/101
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC TP 277 6"
■ Function
2
• Permanent window and template concept for creating screen
templates
• Input/output fields
for visualizing and editing process parameters
• Configurable buttons
with up to 16 functions are also used to directly trigger
functions and actions
• Indicator light
for machine and plant status indication
• Predefined texts
for labeling function keys, process images and process
values in any character size
• Help texts
for process images, messages and variables
• Vector graphics, graphics
can be used as icons instead of text for "labeling" buttons.
They can also be used as background displays (wallpaper).
In the configuration tool, a library is available containing extensive graphics and a wide variety of objects. All editors with an
OLE interface can be used as graphics editors (such as PaintShop, Designer or CorelDraw).
• Curve functions and bars
are used for the display of dynamic values in graphics-based
format
• Dynamic positioning of objects and dynamic showing/hiding
of objects
• Arithmetic functions, limit value monitoring
for reliable process control with inputs and outputs
• Online language selection (16 selectable languages), incl.
Asian and Cyrillic languages
This also applies to language-specific graphics
• Timer
for cyclic function processing
• Password protection (security)
User management – Authentication by means of user ID and
password plus privileges specific to user groups, which is an
integral part of SIMATIC
• Signaling system;
Freely definable message classes (acknowledgement behavior and display can be configured), administration of status,
fault and system alarms. The message history is retained even
if the device is switched off.
Analog alarms (limit value messages) in addition to bit
messages
• Visual Basic Script, flexibility thanks to the implementation of
new functions including linking to variables (comparison
operations, loops, etc.)
• Archiving of messages and process values (on MultiMedia
card or network drives over Ethernet)
- Various archive types: Short-term and sequence archives
- Storage of archive data in standard Windows format (CSV)
- Online evaluation of process value archives through trend
curves
- External processing using standard tools (MS Excel and MS
Access) is possible
2/102
Siemens ST 80 · 2009
• Recipe management
- With additional data storage (on ext. storage medium)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Multi Media Card slot
for external standard data carrier, can be used for backup/
restoration or for transporting recipe data records
• User-friendly maintenance and configuration thanks to:
- Backup and restoration of the configuration, operating
system, data records and firmware on a PC using ProSave
- Option to download/upload the configuration via all device
interfaces (with automatic transfer detection)
- Individual contrast setting and calibration
- Configuration simulation directly on the configuration
computer
Configuring
The equipment is configured using the innovative engineering
tool SIMATIC WinCC flexible 2005 SP1 (Standard version or
higher). SIMATIC WinCC flexible is the logical further development of the field-proven ProTool family. Projects generated using
ProTool can be easily migrated to WinCC. TP 270 6"
projects can be transferred. If WinCC flexible is started directly
from SIMATIC Manager, data in STEP 7 can be accessed
directly at the click of a mouse button when the panel is
configured. Duplicated data input and data management is,
therefore, avoided.
Additional options
• SINUMERIK
Optionally with "SINUMERIK HMI copy license WinCC flexible
CE". For configuring, a "SINUMERIK HMI engineering
package WinCC flexible" is also necessary.
For further information, see Catalog NC 60.
• [email protected] Service
Remote operator control and monitoring of SIMATIC HMI
systems based on TCP/IP networks
• [email protected] Access
Communication between HMI systems based on TCP/IP
networks. Remote access to recipe data sets, passwords and
information specific to the HMI system, and much more.
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC TP 277 6"
■ Technical specifications
TP 277 6"
Supply voltage
TP 277 6"
Operating systems
Supply voltage
24 V DC
Operating system
permissible range
+20.4 V to +28.8 V DC
Processor
Processor
Memory
Type of storage
Type
Flash / RAM
Memory usable for project
data/Options
4 MB usable memory for user
data
Time
Clock
• Type
Software clock, Synchronizable,
not battery backed
2
RISC 32-bit
Functionality under
WinCC flexible
Applications/options
ProAgent, [email protected],
[email protected]
Number of Visual Basic scripts
50
Task planner
Yes
Help system
Yes
Status/control
with SIMATIC S7
Message system
Configuration
Configuration tool
Windows CE
WinCC flexible Standard Version
2005 SP1 or higher (to be ordered
separately)
• Number of messages
4 000
• Bit messages
Yes
Display
• Analog messages
Yes
Display type
TFT, 256 Colors
• Message buffer
Ring buffer (n x 512 entries),
retentive, maintenance-free
Size
5.7"
Resolution (WxH in pixel)
320 x 240
MTBF backlighting (at 25 °C)
about 50,000 hours
Operating mode
Operating elements
Touch screen
Touchscreen
analog, resistive
Numeric/alphabetical input
Yes / Yes
Connection for mouse/keyboard/barcode reader
USB / USB / USB
Ambient conditions
Recipes
• Recipes
300
• Data records per recipe
500
• Entries per data record
1000
• Recipe memory
64 kByte integrated Flash,
expandable (by means of
optional memory card)
Number of process images
• Process images
500
• Variables
2 048
Mounting position
Vertical
• Limit values
Yes
max. relative humidity (in %)
80%
• Multiplexing
Yes
Temperature
Image elements
• Operation
0 °C to +50 °C
• Text objects
10,000 text elements
• Transport, storage
-20 °C to +60 °C
• Graphics object
Bit maps, icons, vector graphics
• dynamic objects
Diagrams, bar graphs, sliders,
analog display, invisible buttons
Degree of protection
Front
IP65, NEMA 4x, (when installed)
Rear
IP20
Certifications & Standards
Certifications
CE, UL, NEMA 4x
I/O Options
I/O devices
Printer, barcode reader
• Text lists
500
• Graphics list
400
• Libraries
Yes
Archiving
• Number of archives per project
Interfaces
Interfaces
1 x RS422, 1 x RS485 (max.
12 MBit/s), 1 x Ethernet (RJ45)
Multi Media Card slot
1 x Multi Media Card slot
USB
Lists
1 x USB
20
• Number of measuring points per 20
project
• Number of entries per archive
10 000
• Memory location
Multi Media Card
Siemens ST 80 · 2009
2/103
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC TP 277 6"
■ Technical specifications (continued)
TP 277 6"
2
Security
• Number of user groups
50
• Passwords exportable
Yes
• Number of user rights
32
Data medium support
Yes
Recording
• Recording/Printing
Alarms, report (shift report), color
print, hardcopy
Fonts
• Keyboard fonts
SIMATIC TP 277 6"
Order No.
F
6AV6 643-0AA01-1AX0
Touch Panel with 5.7" TFT
display, color (256 colors), incl.
mounting accessories
Functionality under
WinCC flexible (continued)
• Multi Media Card
■ Ordering data
US American (English)
Configuration
with SIMATIC WinCC flexible
Configuration set
See Chapter 4
D
6AV6 622-0BA01-0AA0
Consisting of:
• WinCC flexible Standard
engineering software
• Documentation DVD,
5 languages (En, Fr, Ger, It, Sp)
• RS 232 cable (5 m)
• MPI cable, 5 m (for download
and test purposes only)
Applications/Options
Languages
• Online languages
16
When configuration with WinCC
flexible
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
• WinCC flexible/[email protected]
See Chapter 4
• WinCC flexible/[email protected]
See Chapter 4
• WinCC flexible/ProAgent
See Chapter 4
Tahoma, Arial, Courier New,
WinCC flexible Standard, symbol
languages, all freely scalable
• Fonts
Transfer (Upload/Download)
Documentation (to be ordered separately)
TP 277 / OP 277 Operating
Instructions
• German
6AV6 691-1DH01-0AA0
• English
6AV6 691-1DH01-0AB0
Process coupling
• French
6AV6 691-1DH01-0AC0
• Connection to controller
• Italian
6AV6 691-1DH01-0AD0
• Spanish
6AV6 691-1DH01-0AE0
• Transfer of configuration
MPI/PROFIBUS DP, USB, Ethernet,
automatic transfer recognition
S5, S7-200, S7-300/400, TI 505,
SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley
(DF485), Mitsubishi (FX), Telemecanique (ADJUST), OMRON
(LINK/Multilink), Modicon (Modbus), see section on "System
interfaces"
Expandability/openness
• Open Platform Program
Yes
Dimensions
Front of enclosure (W x H)
212 mm x 156 mm
Mounting cutout/Device depth
(W x H/D) in mm
197 mm x 141 mm / 45 mm device
depth
Weights
• Weight
0.78 kg
WinCC flexible Compact/
Standard/Advanced
User Manual
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
WinCC flexible Communication
User Manual
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation,
on DVD
5 languages
(En, Fr, Ger, It and Sp); contains:
all currently available user manuals, manuals and communication
manuals for SIMATIC HMI
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
B) Subject to export regulations: AL: N and ECCN: EAR99S
D) Subject to export regulations: AL: N and ECCN: 5D992B1
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
2/104
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC TP 277 6"
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
Tolerance ± 1 mm.
22
140
156
2
212
44
6
G_ST80_XX_00308
196
■ More information
Additional information is available in the Internet under:
Note:
http://www.siemens.com/panels
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
Siemens ST 80 · 2009
2/105
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC OP 277 6"
■ Overview
■ Application
Thanks to their practical functions and large user memory, the
OP 277 6" Operator Panels can be used wherever operator
control and monitoring of machines and plants is necessary on
site – whether in production automation, process automation or
building-services automation.
2
The OP 277 6" offers a 256-color TFT display. The unit has an
integral PROFINET I/O interface for even greater flexibility. A further highlight is the non-volatile message buffer included as
standard that stores messages permanently without battery
backup.
■ Design
• Operator Panel with comprehensive functions for operator
control and monitoring of machines and plants
• Content of message buffer is retained even when panel is
disconnected, without batteries
• Pixel graphics TFT display with 256 colors
• 36 system keys, 24 freely-configurable and freely-inscribable
function keys (18 with LEDs)
• Interfaces for communication with Siemens SIMATIC S7
(e.g. MPI, PROFIBUS DP) are on-board
• Ethernet on-board
• Use of scripts and archives
• Drivers are also available for non-Siemens PLCs
• Installation-compatible with OP 270 6"
■ Benefits
• Reduction of service and commissioning costs through:
- Backup/restoration via a process interface or optionally via
a Multi Media Card
- Remote downloading of the configuration with automatic
transfer recognition via all device interfaces
- Maintenance-free design (no battery) and long service life of
the backlighting
• Maintenance-free message buffer
• Use of scripts and archives
• Can be used all over the world:
- 32 offline languages can be configured (incl. Asian and
Cyrillic character sets)
- 16 online languages can be selected directly on the device
• Graphics library available with off-the-shelf picture objects
• Standard interfaces for increasing the flexibility:
- External multimedia card, used for recipe data sets, archive
and for backup of configuration/system data
• Integrated USB interface for connecting, for example,
standard printers
• Installation-compatible with OP 270 6"
• Simple engineering supported by comprehensive documentation on the SIMATIC HMI Manual Collection DVD
• Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes engineering outlay, reduces
lifecycle costs
2/106
Siemens ST 80 · 2009
• 256-color TFT display
• CCFL1) Long-life backlighting
• Membrane keyboard with 36 system keys,
24 freely-configurable function keys (18 with LEDs)
• Rugged plastic housing with degree of protection IP65 (front)/
IP20 (rear):
• High performance thanks to RISC processor and 4 MB user
memory, plus additional integrated recipe memory
• The data in the message buffer is retained even when the
panel is disconnected from the supply, without battery backup
• MPI, PROFIBUS DP interfaces (up to 12 Mbaud) as well as
USB 1.1 (max. 100 mA) on-board
• Ethernet (PROFINET I/O capable)
• Integral USB interface
• Can be configured using SIMATIC WinCC flexible 2005
Standard SP1
• Complete functionality for demanding tasks
• Comprehensive Reichert graphics library
• 32 languages (e.g., Cyrillic, traditional Chinese, simplified
Chinese) and online switching between up to 16 languages
• Multi Media Card slot, can be used for standard Multi Media
Cards (for backing up archives and recipe data sets, the
configuration and system data)
• Remote downloading of the configuration via all interfaces
with automatic transfer recognition
• Options for SINUMERIK, [email protected] and [email protected]
can be used
• Service-friendly thanks to maintenance-free design and long
service life of the backlighting display
1)
Cold Cathode Fluorescence Lamps
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC OP 277 6"
■ Function
• Permanent window and template concept for creating screen
templates
• Input/output fields
for visualizing and editing process parameters
• Function keys
for directly actuating functions and actions. Up to 16 functions
can be configured simultaneously on function keys. The
function keys can be used directly as PROFIBUS DP input
peripherals.
• Indicator light
for machine and plant status indication
• Predefined texts
for labeling function keys, process images and process
values in any character size
• Help texts
for process images, messages and variables
• Vector graphics, graphics
can be used as icons instead of text for "labeling" buttons.
They can also be used as background displays (wallpaper).
In the configuration tool, a library is available containing extensive graphics and a wide variety of objects. All editors with an
OLE interface can be used as graphics editors (such as PaintShop, Designer or CorelDraw).
• Curve functions and bars
are used for the display of dynamic values in graphics-based
format
• Dynamic positioning of objects and dynamic showing/hiding
of objects
• Arithmetic functions, limit value monitoring
for reliable process control with inputs and outputs
• Online language selection (16 selectable languages), incl.
Asian and Cyrillic languages
This also applies to language-specific graphics
• Timer
for cyclic function processing
• Password protection (security)
User management – Authentication by means of user ID and
password plus privileges specific to user groups, which is an
integral part of SIMATIC
• Signaling system;
Freely definable message classes (acknowledgement behavior and display can be configured), administration of status,
fault and system alarms. The message history is retained even
if the device is switched off.
Analog alarms (limit value messages) in addition to bit messages
• Visual Basic Script, flexibility thanks to the implementation of
new functions including linking to variables (comparison operations, loops, etc.)
• Archiving of messages and process values (on MultiMedia
card or network drives over Ethernet)
- Various archive types: Short-term and sequence archives
- Storage of archive data in standard Windows format (CSV)
- Online evaluation of process value archives through trend
curves
- External processing using standard tools (MS Excel and MS
Access) is possible
• Recipe management
- With additional data storage (on ext. storage medium)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools such as Excel and
Access is possible
• Multi Media Card (MMC) slot
for external standard data carrier, can be used for backup/restoration or for transporting recipe data records
• User-friendly maintenance and configuration thanks to:
- Backup and restoration of the configuration, operating
system, data records and firmware on a PC using ProSave
- Option to download/upload the configuration via all device
interfaces (with automatic transfer detection)
- Individual contrast setting and calibration
- Configuration simulation directly on the configuration
computer
Configuring
The equipment is configured using the innovative engineering
tool SIMATIC WinCC flexible 2005 SP1 (Standard version or
higher). SIMATIC WinCC flexible is the logical further development of the field-proven ProTool family. Projects generated using
ProTool can be easily migrated to WinCC. OP 270 6"
projects can be transferred. If WinCC flexible is started directly
from SIMATIC Manager, data in STEP 7 can be accessed
directly at the click of a mouse button when the panel is
configured. Duplicated data input and data management is,
therefore, avoided.
Additional options
• SINUMERIK
Optionally with "SINUMERIK HMI copy license WinCC flexible
CE". For configuring, a "SINUMERIK HMI engineering
package WinCC flexible" is also necessary.
For further information, see Catalog NC 60.
• [email protected] Service
Remote operator control and monitoring of SIMATIC HMI
systems based on TCP/IP networks
• [email protected] Access
Communication between HMI systems based on TCP/IP
networks. Remote access to recipe data sets, passwords and
information specific to the HMI system, and much more.
Siemens ST 80 · 2009
2/107
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC OP 277 6"
■ Technical specifications
OP 277 6"
Supply voltage
2
OP 277 6"
Operating systems
Supply voltage
24 V DC
Operating system
permissible range
+20,4 V to +28,8 V DC
Processor
Memory
Processor
Type of storage
Functionality under
WinCC flexible
Type
Flash / RAM
Memory usable for project
data/Options
4 MB usable memory for user data
Time
Clock
• Type
Software clock, Synchronizable,
not battery backed
RISC 32-bit
Applications/options
ProAgent, [email protected],
[email protected]
Number of Visual Basic scripts
50
Task planner
Yes
Help system
Yes
Status/control
with SIMATIC S7
Message system
Configuration
Configuration tool
Windows CE
WinCC flexible Standard Version
2005 SP1 or higher (to be ordered
separately)
• Number of messages
2 000
• Bit messages
Yes
Display
• Analog messages
Yes
Display type
TFT, 256 Colors
• Message buffer
Ring buffer (n x 512 entries),
retentive, maintenance-free
Size
5.7"
Resolution (W x H in pixel)
320 x 240
MTBF backlighting (at 25 °C)
about 50,000 hours
Operating mode
Operating elements
Membrane keyboard
Function keys, programmable
24 function keys, 18 with LEDs
System keys
36
Numeric/alphabetical input
Yes / Yes (only English font can be
displayed, only on screen)
Recipes
• Recipes
300
• Data records per recipe
500
• Entries per data record
1000
• Recipe memory
64 kByte integrated Flash,
expandable
Number of process images
• Process images
500
• Variables
2 048
• Limit values
Yes
Ambient conditions
• Multiplexing
Yes
Mounting position
Vertical
Image elements
max. relative humidity (in %)
80 %
Connection for mouse/
keyboard/barcode reader
USB / USB / USB
Temperature
• Operation
0 °C to +50 °C
• Transport, storage
-20 °C to +60 °C
Degree of protection
Front
IP65
Rear
IP20
Certifications & Standards
Certifications
CE, UL
Printer, barcode reader
Type of output
LED colors
10,000 text elements
Bit maps, icons, vector graphics
• dynamic objects
Diagrams, bar graphs, sliders,
analog display, invisible buttons
Lists
• Text lists
500
• Graphics list
400
• Libraries
Yes
Archiving
I/O/Options
I/O devices
• Text objects
• Graphics object
Green
• Number of archives per project
• Number of entries per archive
10 000
• Memory location
Multi Media Card
Security
Interfaces
Interfaces
1 x RS422, 1 x RS485 (max.
12 MBit/s), 1 x Ethernet (RJ45)
Multi Media Card slot
1 x Multi Media Card slot
USB
1 x USB
• Number of user groups
50
• Passwords exportable
Yes
• Number of user rights
32
Data medium support
• Multi Media Card
2/108
20
• Number of measuring points per 20
project
Siemens ST 80 · 2009
Yes
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC OP 277 6"
■ Technical specifications
■ Ordering data
OP 277 6"
Recording
Alarms, report (shift report),
color print, hardcopy
• Keyboard fonts
Consisting of:
US American (English)
Languages
• Online languages
16
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
Tahoma, Arial, Courier New,
WinCC flexible Standard, symbol
languages, all freely scalable
Transfer (Upload/Download)
MPI/PROFIBUS DP, USB, Ethernet,
automatic transfer recognition
Process coupling
S5, S7-200, S7-300/400, TI 505,
SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley
(DF485), Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus) see section on "System
interfaces"
Expandability/openness
• Open Platform Program
Yes
Dimensions
Front of enclosure (W x H)
Mounting cutout/Device depth
(W x H/D) in mm
308 mm x 204 mm
D
6AV6 622-0BA01-0AA0
• WinCC flexible Standard
engineering software
• Documentation DVD,
5 languages (English, French,
German, Italian, Spanish)
• RS 232 cable (5 m)
• MPI cable, 5 m (for download
and test purposes only)
Applications/Options
When configuration with WinCC
flexible
• WinCC flexible/[email protected]
See Chapter 4
• WinCC flexible/[email protected]
See Chapter 4
• WinCC flexible/ProAgent
See Chapter 4
Documentation (to be ordered separately)
TP 277 / OP 277 Operating
Instructions
• German
6AV6 691-1DH01-0AA0
• English
6AV6 691-1DH01-0AB0
• French
6AV6 691-1DH01-0AC0
• Italian
6AV6 691-1DH01-0AD0
• Spanish
6AV6 691-1DH01-0AE0
281 mm x 177 mm / 59 mm
device depth
WinCC flexible Compact/
Standard/Advanced
User Manual
• German
6AV6 691-1AB01-3AA0
1.19 kg
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
Weights
Weight
2
See Chapter 4
with SIMATIC WinCC flexible
Configuration set
• Connection to controller
6AV6 643-0BA01-1AX0
Configuration
Fonts
• Transfer of configuration
Order No.
F
Operator Panel with 5.7" TFT
display, color (265 colors), incl.
mounting accessories
Functionality under
WinCC flexible (continued)
• Recording/Printing
SIMATIC OP 277 6"
WinCC flexible Communication
User Manual
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation, on DVD
• 5 languages
(En, Fr, Ger, It and Sp); contains:
all currently available user manuals, manuals and communication manuals for SIMATIC HMI
Accessories
Accessories for supplementary
ordering
see HMI accessories,
from page 2/158
B) Subject to export regulations: AL: N and ECCN: EAR99S
D) Subject to export regulations: AL: N and ECCN: 5D992B1
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
Siemens ST 80 · 2009
2/109
© Siemens AG 2008
Operator Control and Monitoring Devices
Panels — 270 series
SIMATIC OP 277 6"
■ Dimensions
All specifications in mm. Panel cutout see technical specifications.
Tolerance ± 1 mm.
176
204
2
57
308
6
280
G_ST80_XX_00307
197
■ More information
Additional information is available in the Internet under:
Note:
http://www.siemens.com/panels
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific products that can be ordered as well as about options for customerspecific modification and adaptation.
2/110
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 170 series
SIMATIC MP 177
■ Overview
• Like operator panels, Multi Panels (MP) are used for local
machine operation and monitoring
• Message buffer contents and residual WinAC MP data are
retained even when panel is disconnected, without batteries
• PLC functionality can be integrated directly into the MP 177
platform as an option
• The multi panel can be expanded with the options
[email protected] and [email protected]
• Pixel-graphics 5.7" TFT display, color (64k colors)
• All interfaces, e.g. MPI, PROFIBUS DP, USB,
PROFINET (Ethernet TCP/IP), are on-board
The MP 177 6" Touch can also be delivered as a package,
complete with a WinAC MP 177. WinCC flexible 2008 Compact
or higher is required for configuring the MP 177.
■ Benefits
• Integral component of Totally Integrated Automation (TIA):
Increased productivity, minimum engineering overhead,
reduction in life-cycle costs
• Modular expansion with options such as:
- WinAC MP 177/Software PLC (PLC programs compatible to
the greatest possible extent)
- WinCC flexible/[email protected] for communication between
different SIMATIC HMI systems
- WinCC flexible/[email protected] for remote maintenance and
servicing of machines/plants via the intranet/Internet
- WinCC flexible/ProAgent for selective and fast process fault
diagnostics in systems and machines
• Reduction of service and commissioning costs through:
- Backup/Restore via Ethernet (TCP/IP), MPI, PROFIBUS DP
or optionally via standard MMC/SD card or USB stick
- HMI, PLC, system data including licenses for a standard
storage medium, simplest manageability
- Remote download/upload of the configuration and firmware
(Remote = automatic transfer recognition)
- Specific drivers for non-Siemens PLCs can be reloaded
- Long service life of the backlighting
• Can be used worldwide:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
• Standard hardware and software interfaces for increasing
flexibility:
- SD/MultiMediaCard slot for memory expansions, backup/
restore or additional interfaces
- Ethernet (TCP/IP) for central data and project management
Ethernet; control link possible to SIMATIC S7
- A cross cable or normal LAN cable can be used for the
point-to-point connection
- Standard Windows storage formats (CSV) for recipes permit
further processing with standard tools (e.g. Microsoft Excel)
■ Application
Multi panels are used in the most diverse industries and applications. Their usage can be expanded by means of options, e.g.
integration of the PLC functionality by means of WinAC MP 177.
The software PLC is customized for small and mid-sized applications.
The diskless and fanless design enables implementation in areas where high vibration or dust load limits the operation of a PC.
Maintenance-free data management ensures backup of all important data even when disconnected.
Siemens ST 80 · 2009
2/111
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 170 series
SIMATIC MP 177
■ Design
2
■ Function
• Compact design with low mounting depth
- Display resolution (320 x 240 pixels) with 64k colors,
dimmable
• The front is resistant to various oils, greases and standard
detergents
• Degree of protection IP65/NEMA 4x/NEMA 12 (front) or IP20
(rear)
• All connections are pluggable
• Interfaces:
- RS 485/RS 422 interface for process connections
(PPI, MPI, PROFIBUS DP up to 12 Mbit/s)
- USB interface for memory, mouse, keyboard, printer, and
downloading/uploading of the configuration
- Ethernet (TCP/IP) for data exchange with a higher-level PC
- Slot for SD Card/Multi Media Card
■ Function
• Display and modification of process parameters
• Process display:
- Vector graphics (various line and surface objects)
- Dynamic positioning and dynamic showing/hiding of objects
- Pixel-graphic displays and bar displays
- Curve graphics with paging and zoom functions for access
to the history and for flexible selection of the presentation
time; reading ruler for determining the current values and
displaying them in a table
- Extensive symbol libraries (SIMATIC HMI Symbol Library)
- Screen objects: Slider, analog instrument, date and time
display
- Timer for cyclical function processing
• Multiplex function for variables
• Signaling system
- Bit messages and analog messages (limit value messages)
- Message history for status and fault messages
- Message buffer stores even when panel is disconnected,
without batteries
- Message window and message line
• Message log and shift log
• Print functions (see "Recommended printers")
• Fully developed language switching for texts and graphics
including Asian and Cyrillic character sets
• Recipe management
- Internal and/or external data storage
- Export of recipe data in standard Windows format (CSV)
• TIA Runtime Functionalities
- A collective data management for PLC and HMI of data, bit
memories, inputs/outputs, etc.
- Collective usage of symbolic object names
- Report system errors with Alarm S to SIMATIC S7 and
SIMOTION with a mouse click
- STATUS/FORCE-VAR in conjunction with SIMATIC S7
• Password system
- Authentication and assignment of user rights with user ID
and password
2/112
Siemens ST 80 · 2009
Configuration
The configuration is implemented using the engineering software SIMATIC WinCC flexible 2008 Standard or Advanced.
Applications/Options
• WinAC MP software PLC for Multi Panels
- WinAC MP 177 option for MP 177 (software PLC similar to the
performance class of CPU 314)
- The I/O devices can be connected via PROFIBUS DP
- Note: Utilization of the software PLC requires
WinCC flexible 2008 and an MP177 6" Touch
• Service functions with option "[email protected]" can be used
- E-mail generation and web server can be used
- Remote control of the SIMATIC HMI panel using a standard
Internet Explorer
• Client/server functions with the option "[email protected]" can be
used
- Remote operation and monitoring from one SIMATIC HMI
system to another SIMATIC HMI system
- Plant-wide polling of information
- Central archiving of process data
■ Integration
The MP 177 6" Touch is multi-protocol-capable and can be
connected to some extent simultaneously to:
• SIMATIC S7-200/-300/-400
• SIMATIC WinAC RTX/Slot PLC
• SIMATIC WinAC MP
• SIMOTION
• SINUMERIK
(optionally with "SINUMERIK HMI copy license WinCC flexible
CE"; the "SINUMERIK HMI engineering package WinCC flexible"
is additionally required for configuration; for further information
see Catalog NC 60)
• PLCs from other manufacturers
- Allen Bradley
- Mitsubishi
- LG GLOFA GM
- Modicon
- GE-Fanuc
- Omron
- Telemecanique Uni-Telway
• Over Ethernet (TCP/IP) to a higher-level PC, with enabled
network printer
Note:
Further information can be found under "System interfaces".
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 170 series
SIMATIC MP 177
■ Technical specifications
MP 177
6" Touch
Supply voltage
MP 177
Supply voltage
24 V DC
permissible range
+19.2 V to 28.8 V DC
Memory
Type of storage
Type
Flash / RAM
Memory usable for project
data/Options
2 MB usable memory for
user data
Interfaces
1 x RS422, 1 x RS485
(max. 12 Mbit/s),
1 x Ethernet (RJ45)
Multi Media Card slot
1 x Multi Media Card slot
USB
1 x USB
2
Operating systems
Operating system
Windows CE (Version 5)
Processor
Time
Clock
Processor
• Type
Functionality under
WinCC flexible
Hardware clock, battery backed,
Synchronizable
Configuration
Configuration tool
6" Touch
Interfaces
WinCC flexible Standard Version
2008 or higher (to be ordered
separately)
Display
RISC 32 Bit, 520 MHz
Applications/options
Soft PLC, [email protected],
[email protected]
Task planner
Yes
Help system
Yes
Status/control
with SIMATIC S7
Display type
TFT, 65 536 Colors
Size
5.7"
• Number of messages
2 000
Resolution (W x H in pixel)
320 x 240
• Bit messages
Yes
MTBF backlighting (at 25 °C)
about 50,000 hours
• Analog messages
Yes
• Message buffer
Ring buffer (n x 256 entries),
retentive, maintenance-free
Operating mode
Message system
Operating elements
Touch screen
Touchscreen
analog, resistive
Recipes
Numeric/alphabetical input
Yes (on-screen keyboard) / Yes
(on-screen keyboard)
• Recipes
100
• Data records per recipe
200
USB / USB / USB
• Entries per data record
200
• Recipe memory
32 kByte integrated Flash,
expandable
Connection for mouse/keyboard/barcode reader
EMC
• Emission of radio interferences to Yes; EN 61000-6-4, interference
EN 55 011 (limit class A)
emission: Intended for use in
industrial areas.
Number of process images
• Process images
500
Ambient conditions
• Variables
1 000
Mounting position
Vertical
• Limit values
Yes
Max. relative humidity (in %)
90 %
• Multiplexing
Yes
Image elements
Temperature
• Operation
• Transport, storage
0 °C to +50 °C
• Text objects
2.500 text elements
-20 °C to +70 °C
• Graphics object
Bit maps, icons,
vector graphics
• Dynamic objects
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Degree of protection
Front
IP65, NEMA 4, NEMA 4x,
NEMA 12 (when installed)
Rear
IP20
Lists
• Text lists
300
CE, FM Class I Div. 2, cULus,
C-TICK, NEMA 4, NEMA 4x,
NEMA 12
• Graphics list
100
• Libraries
Yes
Certifications & Standards
Certifications
I/O Options
I/O devices
Printer, barcode reader
Siemens ST 80 · 2009
2/113
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 170 series
SIMATIC MP 177
■ Technical specifications (continued)
MP 177
2
6" Touch
Functionality under
WinCC flexible (continued)
Security
■ Ordering data
6AV6 642-0EA01-3AX0
SIMATIC MP 177 6" Touch
package
on request
• Number of user groups
50
Consisting of:
• Passwords exportable
Yes
• SIMATIC MP 177 6" Touch
• Number of user rights
32
• SIMATIC WinAC MP
Yes
• Single License for WinAC
MP 177 on USB stick1)
Data medium support
• Multi Media Card
Recording
• Recording/Printing
Alarms, report (shift report),
color print, hardcopy
• Printer driver
ESC/P2, PCL3/PCL6
Fonts
• Keyboard fonts
US American (English)
Languages
• Online languages
16
• Configuration languages
D, GB, F, I, E, CHN "traditional",
CHN "simplified", DK, FIN, GR, J,
KP / ROK, NL, N, PL, P, RUS, S,
CZ / SK, TR, H
Tahoma, Courier New, WinCC
flexible Standard, symbol
languages, all freely scalable
• Fonts
Transfer (Upload/Download)
• Transfer of configuration
MPI/PROFIBUS DP, serial, USB,
Ethernet, automatic transfer
recognition
Process coupling
• Connection to controller
S7-200, S7-300/400, TI 505, Win
AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley
(DF485), Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus), see "System interfaces"
Dimensions
Order No.
SIMATIC MP 177 6" Touch
min. WinCC flexible 2008
necessary
• Electronic documentation for
WinAC MP
• Standard SD card 256 MB
(empty)
Configuration
with SIMATIC WinCC flexible
See HMI Software
• WinCC flexible/[email protected]
See HMI Software
• WinCC flexible/[email protected]
See HMI Software
• WinAC MP/software PLC
See HMI Software
Documentation (to be ordered separately)
User manual MP 177 6" Touch
• German
6AV6 691-1DP02-0AA0
• English
6AV6 691-1DP02-0AB0
• French
6AV6 691-1DP02-0AC0
• Italian
6AV6 691-1DP02-0AD0
• Spanish
6AV6 691-1DP02-0AE0
WinCC flexible
Compact/Standard/Advanced
User Manual
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
Front of enclosure (W x H)
212 mm x 156 mm
User Manual
WinCC flexible Communication
Mounting cutout/Device depth
(W x H/D) in mm
198 mm x 142 mm /
45 mm device depth
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Weights
Weight
0.85 kg
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
Accessories
Accessories for
supplementary ordering
See HMI Accessories
B) Subject to export regulations: AL: N and ECCN: EAR99S
1)
2/114
Siemens ST 80 · 2009
Can only be used for license handling
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 170 series
SIMATIC MP 177
■ Dimensions
■ More information
Additional information is available in the Internet under:
All specifications in mm. Tolerance ± 1 mm.
http://www.siemens.com/mp
2
44
6
G_ST80_XX_00366
196
22
212
Do you a require specific modification or extension to the
products described here? Then have a look under "Customerspecific Products." There you will find information about additional and general industry products available for order as well
as options for customized modifications and adaptations.
140
156
Notice:
MP 177 6" Touch
Siemens ST 80 · 2009
2/115
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Overview
■ Benefits
2
• Like operator panels, Multi Panels (MP) are used for local
machine operation and monitoring
• Content of message buffer is retained even when panel is
disconnected, without batteries
• PLC functionality can be integrated directly into the MP277
platform with Option
• Their functionality can be expanded by the installation of
additional Windows CE applications (Multi Panel and Panel
options)
• SIMATIC MP 277 devices on the basis of Windows CE
combine the rugged construction of Operator Panels with the
flexibility of PCs
• Pixel-graphics 7.5" or 10.4" TFT display, color (64k colors)
• MP 277 8" and MP 277 10" Touch:
Touch screen (analog/resistive)
MP 277 8" Key:
38 system keys, 26 user-configurable and freely inscribable
function keys (18 with LEDs)
MP 277 10" Key:
38 system keys, 36 user-configurable and freely inscribable
function keys (28 with LEDs)
• The MP 277 is also available with a stainless steel front panel,
and therefore meets the high requirements of, e.g., the food
and beverage industry.
• All interfaces, e.g. MPI, PROFIBUS DP, USB, PROFINET
(Ethernet TCP/IP), are onboard
2/116
Siemens ST 80 · 2009
• Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• Modular expansion with options such as:
- WinAC MP 277/Software PLC
- WinCC flexible/[email protected] for communication between
different SIMATIC HMI systems
- WinCC flexible/[email protected] for remote maintenance and
servicing of machines/plants via the Intranet/Internet
- WinCC flexible/OPC-Server for communication with
applications from various manufacturers
- Microsoft Pocket Internet Explorer (already included in the
scope of delivery)
IE6 for Win CE is included with WinCC flexible 2007.
- WinCC flexible/ProAgent for selective and fast process fault
diagnostics in systems and machines
- WinCC flexible/Audit for user management (tracing and user
operations)
• Reduction of service and commissioning costs through:
- Backup/Restore via Ethernet (TCP/IP), USB, MPI,
PROFIBUS DP or optionally via SD/Multi Media Card
- Remote download/upload of the configuration and firmware
(Remote = automatic transfer recognition)
- Specific drivers can be reloaded
- Long service life of the backlighting
• Graphics library available with off-the-shelf picture objects
• Can be used worldwide:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
- Up to 16 languages can be switched online
• Standard hardware and software interfaces for increasing
flexibility:
- SD/MultiMediaCard slot for memory expansions, backup/
restore or additional interfaces
- Ethernet (TCP/IP) for central data and project management
Ethernet; control link possible to SIMATIC S7
- Standard Windows storage formats (CSV) for archives and
recipes permit further processing with standard tools (e.g.
Microsoft Excel)
■ Application
They are used in a wide range of industries and applications
which can be extended by means of the Multi Panel options, e.g.
presentation of HTML documents via Microsoft Pocket Internet
Explorer.
The diskless and fanless design permits their use even where
dust or vibration limits the use of a PC. Short power-up times
mean the Multi Panels are soon ready to use.
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Design
• Compact design with low mounting depth
• The front is resistant to various oils, greases and standard
detergents
• Degree of protection IP65/NEMA 4x/NEMA 12 (front) or IP20
(rear)
• Plug-in terminals for 24 V DC power supply
• Interfaces:
- RS 485/ RS 422 interface for process connections (PPI, MPI,
PROFIBUS DP up to 12 Mbit/s)
- USB for memory stick, mouse, keyboard, printer, barcode
reader, UPS and downloading/uploading the configuration
- Ethernet (TCP/IP) for exchanging data with a higher-level
PC, connection of a network printer and downloading/
uploading the configuration;
a control link to SIMATIC S7 is possible
• Slot for SD/MultiMedia card
■ Function
• Display and modification of process parameters
• Function keys (for MP 277 8" Key and MP 277 10 "Key only):
For direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on function keys.
• Process display:
- VGA resolution (640 x 480 pixels)
each with 64k colors for pixels
- Vector graphics (various line and surface objects)
- Dynamic positioning and dynamic showing/hiding of objects
- Pixel-graphic displays, curves and bar displays
- Presentation of up to 8 curves in a curve field;
curve graphics with paging and zoom functions for access
to the history and for flexible selection of the presentation
time;
reading ruler for determining the current values and displaying them in a table
- Extensive symbol libraries (SIMATIC HMI symbol library)
- Screen objects: Slider, gauge, clock
- Cyclic function processing using timers
• Multiplex function for variables
• Signaling system:
- Bit messages and analog messages (limit value messages)
- Freely-definable message classes (e.g. status/fault messages) for definition of acknowledgment response and display of message events
- Status and fault messages with message history
- Non-volatile, maintenance-free message buffer
- Message window and message line
• Archiving of messages and process values (on CF/SD/
MultiMedia card/USB, etc., or network drives over Ethernet):
- Various archive types: Circular and sequential archives
- Storage of archive data in standard Windows format (CSV)
- Online evaluation of process value archives through trend
curves
- External evaluation using standard tools
(MS Excel and MS Access) is possible
• Message log and shift log
• Print functions (see "Recommended printers")
• Language selection:
16 online languages, 32 configuration languages incl. Asian
and Cyrillic character sets; language-dependent texts and
graphics
• Recipe management:
- With additional data storage (on SD/MultiMedia card)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External evaluation using standard tools (Microsoft Excel
and Access) is possible
• TIA Runtime Functionalities:
- Direct keys (fast keys; with Key as keyboard image, with
Touch freely customizable) used directly as PROFIBUS DP
or PROFINET IO input peripherals
- With Key variants, LEDs additional as output peripherals
- In addition, message process Alarm S with SIMATIC S7 and
SIMOTION
- Programming device functionality STATUS/FORCE-VAR in
conjunction with SIMATIC S7
- SIMATIC barcode scanner
- Direct activation and evaluation of a SITOP UPS via USB
• Display selection from the PLC
supports operator prompting from the PLC
• Presentation of HTML documents with MS Pocket Internet
Explorer / WinCC flexible 2007 or higher: Internet Explorer 6
for Win CE
• Visual Basic Script, flexibility thanks to the implementation of
new functions including linking to variables (comparison
operations, loops, etc.)
• Help texts:
For process images, messages and variables
• Arithmetic functions
• Limit value monitoring:
For reliable process control of inputs and outputs
• Permanent window:
Fixed top area of screen for outputting non-screen-specific
information (e.g., important process values, date and time)
• Simple maintenance and configuration thanks to:
- Save and load (Backup/Restore -> Image) complete (incl.
License Keys as of WinCC flexible 2007) panels on an
SD/MultiMedia Card (optional), also possible with remote
access ([email protected])
- Save and load (Backup/Restore -> Image) complete
(besides License Key) panels on a PC
- Configuration download using Ethernet/USB/MPI/
PROFIBUS DP/Modem/http
- Configuration upload using Ethernet/USB/MPI/
PROFIBUS DP/modem/http, the project is compressed
during the download and transferred to the SD/MultiMedia
Card or USB stick (optional)
- Automatic Transfer Recognition (Remote Transfer)
- Configuration simulation directly on the configuration
computer
- Import/export of all texts incl. messages in CSV format for
translation using standard text processing programs
- Centrally modifiable project-specific faceplates
• Template:
- Creation of screen templates
- Position-independent configuration of background objects
• Password system:
- User-oriented access protection according to requirements
of specific sectors
- Authentication with user ID and password
- User-group-specific rights
Siemens ST 80 · 2009
2/117
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Function (continued)
2
• Service functions (optionally with "WinCC flexible /
[email protected]"):
- Email generation
- Remote control of the SIMATIC HMI system based on
Internet Explorer
- Web server with status HTML pages and control functions
• Client/server functions (optionally with "WinCC flexible
/[email protected]"):
- Remote operation and monitoring from other SIMATIC HMI
systems
- Plant-wide requests for information and archiving of
process data
Configuration
Configuration is carried out with the
SIMATIC WinCC flexible SP1 Standard or Advanced
engineering software (see SIMATIC WinCC flexible HMI
software/engineering software).
Projects (of earlier panels) created with ProTool can be
transferred to WinCC flexible.
Applications/options
• WinAC MP2007 Software PLC for multipanels
WinAC MP277 option for MP277 (software PLC similar to the
performance class CPU 315)
The I/O devices can be connected via PROFIBUS DP
Note: Utilization of the Software PLC requires WinCC flexible
2007 and MP277 hardware with integrated retentive memory
• WinCC flexible /[email protected];
Remote operation and monitoring as well as communication
between different SIMATIC HMI systems (see HMI software/
runtime software SIMATIC WinCC flexible /WinCC flexible RT
options)
• WinCC flexible /[email protected];
Remote maintenance and servicing of machines/plants via the
Intranet/Internet (see HMI software/runtime software SIMATIC
WinCC flexible /WinCC flexible RT options)
• WinCC flexible /OPC server
Communication with applications (e.g. MES, ERP, or applications in the office sector) from various manufacturers (see HMI
software/runtime software SIMATIC WinCC flexible /WinCC
flexible RT options)
• WinCC flexible/Audit
• WinCC flexible/ProAgent
• SINUMERIK
2/118
Siemens ST 80 · 2009
■ Integration
The MP 277 can in certain cases be connected simultaneously
(multiprotocol-capable) to:
• SIMATIC S7-200/-300/-400
• SIMATIC WinAC Software/Slot PLC
• SIMATIC WinAC MP 2007
• SIMATIC S5
• SIMATIC 505
• http communication to other SIMATIC HMI systems (optionally
with "WinCC flexible /[email protected]" option)
• SIMOTION
• SINUMERIK
(optionally with "SINUMERIK HMI copy licence WinCC flexible
CE"; "SINUMERIK HMI engineering package WinCC flexible"
is additionally required for configuring;
For further details, see Catalog NC 60)
• OPC XML Server (optionally with "WinCC flexible/
OPC-Server")
• PLCs from other manufacturers
- Allen Bradley
- Mitsubishi
- LG GLOFA GM
- Modicon
- GE-Fanuc
- Omron
- Telemecanique Uni-Telway
• Via Ethernet (TCP/IP) to a higher-level PC, with enabled
network printer
Note:
Further information can be found under "System interfaces".
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Technical specifications
SIMATIC MP 277
8" Color TFT
display, Touch
10" Color TFT
display, Touch
8" Color TFT
display, keyboard
10" Color TFT
display, keyboard
10" Color TFT
display, Touch,
INOX
Supply voltage
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
Permissible range
+20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC
2
Supply voltage
Memory
Type of storage
Type
Flash / RAM
Memory usable for project
data/Options
6 MB usable memory 6 MB usable memory 6 MB usable memory 6 MB usable memory 6 MB usable memory
for user data
for user data
for user data
for user data
for user data
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Time
Clock
• Type
Hardware clock,
battery backed,
Synchronizable
Hardware clock,
battery backed,
Synchronizable
Hardware clock,
battery backed,
Synchronizable
Hardware clock,
battery backed,
Synchronizable
Hardware clock,
battery backed,
Synchronizable
WinCC flexible Standard Version 2005
SP1 or higher (to be
ordered separately)
WinCC flexible Standard Version 2005
SP1 or higher (to be
ordered separately)
WinCC flexible Standard Version 2005
SP1 or higher (to be
ordered separately)
WinCC flexible Standard Version 2005
SP1 or higher (to be
ordered separately)
WinCC flexible Standard Version 2005
SP1 or higher (to be
ordered separately)
Configuration
Configuration tool
Display
Display type
TFT, 65536 Colors
TFT, 65536 Colors
TFT, 65536 Colors
TFT, 65536 Colors
TFT, 65536 Colors
Size
7.5"
10.4"
7.5"
10.4"
10.4"
Resolution (W x H in pixel)
640 x 480
640 x 480
640 x 480
640 x 480
640 x 480
MTBF backlighting (at 25 °C)
about 50,000 hours
about 50,000 hours
about 50,000 hours
about 50,000 hours
about 50,000 hours
Touch screen
Touch screen
Membrane keyboard Membrane keyboard Touch screen
Operating mode
Operating elements
Function keys, programmable
System keys
26 function keys,
18 with LEDs
36 function keys,
26 with LEDs
36
36
Touchscreen
analog, resistive
analog, resistive
analog, resistive
Numeric/alphabetical input
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Connection for mouse/keyboard/barcode reader
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
Ambient conditions
Mounting position
Vertical
Vertical
Vertical
Vertical
Vertical
maximum permissible angle
of incliniation without external
ventilation
+/- 35°
+/- 35°
+/- 35°
+/- 35°
+/- 35°
max. relative humidity (in %)
90%
90%
90%
90%
90%
• Operation
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Front
IP65, NEMA 4x,
(when installed)
IP65, NEMA 4x,
(when installed)
IP65, NEMA 4x,
(when installed)
IP65, NEMA 4x,
(when installed)
IP66K, NEMA 4x,
(when installed)
Rear
IP20
IP20
IP20
IP20
IP20
Temperature
Degree of protection
Siemens ST 80 · 2009
2/119
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Technical specifications (continued)
SIMATIC MP 277
2
8" Color TFT
display, Touch
10" Color TFT
display, Touch
CE, FM Class I Div. 2,
UL, cULus, EX-Zone
22, NEMA 4x
(Enclosure Type 4X,
Type 12)
Printer, barcode
reader
8" Color TFT
display, keyboard
10" Color TFT
display, keyboard
10" Color TFT
display, Touch,
INOX
CE, FM Class I Div. 2, CE, UL, cULus,
UL, cULus, EX-Zone NEMA 4x (Enclosure
22, NEMA 4x
Type 4X, Type 12)
(Enclosure Type 4X,
Type 12)
CE, FM Class I Div. 2,
UL, cULus, EX-Zone
22, NEMA 4x
(Enclosure Type 4X,
Type 12)
CE, FM Class I Div. 2,
UL, CSA, cULus, EXZone 2, EX-Zone 22,
NEMA 4x (Enclosure
Type 4X, Type 12)
Printer, barcode
reader
Printer, barcode
reader
Printer, barcode
reader
Printer, barcode
reader
Green
Green
1 x RS422, 1 x
RS485, 1 x Ethernet
(RJ45)
1 x RS422, 1 x
RS485, 1 x Ethernet
(RJ45)
Certifications & Standards
Certifications
I/O/Options
I/O devices
Type of output
LED colors
Interfaces
Interfaces
1 x RS422, 1 x
RS485, 1 x Ethernet
(RJ45)
1 x RS422, 1 x
RS485, 1 x Ethernet
(RJ45)
1 x RS422, 1 x
RS485, 1 x Ethernet
(RJ45)
Multi Media Card slot
1 x Multi Media Card 1 x Multi Media Card 1 x Multi Media Card 1 x Multi Media Card 1 x Multi Media Card
slot
slot
slot
slot
slot
USB
2 x USB
2 x USB
2 x USB
2 x USB
2 x USB
Windows CE
Windows CE
Windows CE
Windows CE
Windows CE
ARM
ARM
ARM
ARM
ARM
Applications/options
ProAgent, Internet
Explorer, Soft-PLC,
[email protected],
[email protected]
ProAgent, Internet
Explorer, Soft-PLC,
[email protected],
[email protected]
ProAgent, Internet
Explorer, Soft-PLC,
[email protected],
[email protected]
ProAgent, Internet
Explorer, Soft-PLC,
[email protected],
[email protected]
ProAgent, Internet
Explorer, Soft-PLC,
[email protected],
[email protected]
Number of Visual Basic scripts
50
50
50
50
50
Task planner
Yes
Yes
Yes
Yes
Yes
Help system
Yes
Yes
Yes
Yes
Yes
Status/control
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
• Number of messages
4 000
4 000
4 000
4 000
4 000
• Bit messages
Yes
Yes
Yes
Yes
Yes
• Analog messages
Yes
Yes
Yes
Yes
Yes
• Message buffer
Ring buffer (n x 512
entries), retentive,
maintenance-free
Ring buffer (n x 512
entries), retentive,
maintenance-free
Ring buffer (n x 512
entries), retentive,
maintenance-free
Ring buffer (n x 512
entries), retentive,
maintenance-free
Ring buffer (n x 512
entries), retentive,
maintenance-free
Operating systems
Operating system
Processor
Processor
Functionality under WinCC
flexible
Message system
Recipes
• Recipes
300
300
300
300
300
• Data records per recipe
500
500
500
500
500
• Entries per data record
1000
1000
1000
1000
1000
• Recipe memory
64 kByte integrated
Flash, expandable
64 kByte integrated
Flash, expandabler
64 kByte integrated
Flash, expandable
64 kByte integrated
Flash, expandable
64 kByte integrated
Flash, expandable
2/120
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Technical specifications (continued)
SIMATIC MP 277
8" Color TFT
display, Touch
10" Color TFT
display, Touch
8" Color TFT
display, keyboard
10" Color TFT
display, keyboard
10" Color TFT
display, Touch,
INOX
2
Functionality under WinCC
flexible (continued)
Number of process images
• Process images
500
500
500
500
500
• Variables
2 048
2 048
2 048
2 048
2 048
• Limit values
Yes
Yes
Yes
Yes
Yes
• Multiplexing
Yes
Yes
Yes
Yes
Yes
Image elements
• Text objects
10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements
• Graphics object
Bit maps, icons,
vector graphics
Bit maps, icons,
vector graphics
Bit maps, icons,
vector graphics
Bit maps, icons,
vector graphics
Bit maps, icons,
vector graphics
• dynamic objects
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Lists
• Text lists
500
500
500
500
500
• Graphics list
400
400
400
400
400
• Libraries
Yes
Yes
Yes
Yes
Yes
Archiving
• Number of archives per project 20
20
20
20
20
• Number of measuring points
per project
20
20
20
20
20
• Number of entries per archive
10 000
10 000
10 000
10 000
10 000
• Memory location
SD and Multi Media
Card
SD and Multi Media
Card
SD and Multi Media
Card
SD and Multi Media
Card
SD and Multi Media
Card
Security
• Number of user groups
50
50
50
50
50
• Passwords exportable
Yes
Yes
Yes
Yes
Yes
• Number of user rights
32
32
32
32
32
Yes
Yes
Yes
Yes
Yes
Alarms, report
(shift report),
color print,
hardcopy
Alarms, report
(shift report),
color print,
hardcopy
Alarms, report
(shift report),
color print,
hardcopy
Alarms, report
(shift report),
color print,
hardcopy
Alarms, report
(shift report),
color print,
hardcopy
US American
(English)
US American
(English)
US American
(English)
US American
(English)
US American
(English)
Data medium support
• Multi Media Card
Recording
• Recording/Printing
Fonts
• Keyboard fonts
Languages
• Online languages
16
16
16
16
16
• Configuration languages
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
Tahoma, Arial,
Courier New, WinCC
flexible Standard,
symbol languages,
all freely scalable
Tahoma, Arial,
Courier New, WinCC
flexible Standard,
symbol languages,
all freely scalable
Tahoma, Arial,
Courier New, WinCC
flexible Standard,
symbol languages,
all freely scalable
Tahoma, Arial,
Courier New, WinCC
flexible Standard,
symbol languages,
all freely scalable
Tahoma, Arial,
Courier New, WinCC
flexible Standard,
symbol languages,
all freely scalable
Siemens ST 80 · 2009
2/121
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Technical specifications (continued)
SIMATIC MP 277
2
8" Color TFT
display, Touch
10" Color TFT
display, Touch
8" Color TFT
display, keyboard
10" Color TFT
display, keyboard
10" Color TFT
display, Touch,
INOX
MPI/PROFIBUS DP,
USB, Ethernet,
automatic transfer
recognition
MPI/PROFIBUS DP,
USB, Ethernet,
automatic transfer
recognition
MPI/PROFIBUS DP,
USB, Ethernet,
automatic transfer
recognition
MPI/PROFIBUS DP,
USB, Ethernet,
automatic transfer
recognition
MPI/PROFIBUS DP,
USB, Ethernet,
automatic transfer
recognition
S5, S7-200, S7300/400, TI 505,
SINUMERIK,
SIMOTION, Allen
Bradley (DF1), Allen
Bradley (DF485),
Mitsubishi (FX),
OMRON (LINK/
Multilink), Modicon
(Modbus) see
section on "System
interfaces"
S5, S7-200, S7300/400, TI 505,
SINUMERIK,
SIMOTION, Allen
Bradley (DF1), Allen
Bradley (DF485),
Mitsubishi (FX),
OMRON (LINK/
Multilink), Modicon
(Modbus) see
section on "System
interfaces"
S5, S7-200, S7300/400, TI 505,
SINUMERIK,
SIMOTION, Allen
Bradley (DF1), Allen
Bradley (DF485),
Mitsubishi (FX),
OMRON (LINK/
Multilink), Modicon
(Modbus) see
section on "System
interfaces"
S5, S7-200, S7300/400, TI 505,
SINUMERIK,
SIMOTION, Allen
Bradley (DF1), Allen
Bradley (DF485),
Mitsubishi (FX),
OMRON (LINK/
Multilink), Modicon
(Modbus) see
section on "System
interfaces"
S5, S7-200, S7300/400, TI 505,
SINUMERIK,
SIMOTION, Allen
Bradley (DF1), Allen
Bradley (DF485),
_Mitsubishi (FX),
OMRON (LINK/
Multilink), Modicon
(Modbus) see
section on "System
interfaces"
Yes
Yes
Yes
Yes
Yes
Front of enclosure (W x H)
240 mm x 180 mm
325 mm x 263 mm
352 mm x 221 mm
483 mm x 310 mm
325 mm x 263 mm
Mounting cutout/Device depth
(W x H/D) in mm
226 mm x 166 mm / 310 mm x 248 mm / 338 mm x 206 mm / 434 mm x 291 mm / 310 mm x 248 mm /
60 mm device depth 61 mm device depth 61 mm device depth 60 mm device depth 61 mm device depth
Functionality under WinCC
flexible (continued)
Transfer (Upload/Download)
• Transfer of configuration
Process coupling
• Connection to controller
Expandability/openness
• Open Platform Program
Dimensions
Weights
• Weight
2/122
1.61 kg
Siemens ST 80 · 2009
2.65 kg
2.25 kg
4.95 kg
4.2 kg
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Ordering data
Order No.
SIMATIC MP 277
Order
Configuration
with SIMATIC WinCC flexible
Multi Panel (including installation
accessories) with
Configuration set
• 8" color TFT display, Touch
F
6AV6 643-0CB01-1AX1
• 10" color TFT display, Touch
F
6AV6 643-0CD01-1AX1
• 8" color TFT display, keyboard
F
6AV6 643-0DB01-1AX1
• 10" color TFT display, keyboard F
6AV6 643-0DD01-1AX1
• 10" color TFT display, Touch, INOX
(with stainless steel front panel)
6AV6 643-0ED01-2AX0
SIMATIC MP 277 8" Touch
Starter Package
6AV6 652-3MB01-0AA0
F
See HMI Software
D
6AV6 622-0BA01-0AA0
• WinCC flexible Standard
engineering software
• Documentation DVD,
5 languages (English, French,
German, Italian, Spanish)
• RS 232 cable (5 m)
• MPI cable, 5 m
Consisting of:
Applications/Options
• SIMATIC MP 277 8" Touch
When configuration with WinCC
flexible
• SIMATIC WinCC flexible 2007
• WinCC flexible/[email protected]
See Chapter 4
• WinCC flexible/[email protected]
See Chapter 4
• WinCC flexible/OPC Server
See Chapter 4
• MPI cable, 5 m (for download
and test purposes only)
• WinCC flexible/ProAgent
See Chapter 4
• WinCC flexible/Audit
See Chapter 4
• PC/PPI cable (RS 232)
• WinAC MP 2007/Software PLC
see page 2/135
• SIMATIC HMI Manual Collection
• Voucher for Software Update
Service for 1 year
SIMATIC MP 277 10" Touch
Starter Package
F
6AV6 652-3PB01-0AA0
• SIMATIC MP 277 10" Touch
• SIMATIC WinCC flexible 2007
• SIMATIC HMI Manual Collection
• Voucher for Software Update
Service for 1 year
• PC/PPI cable (RS 232)
Complete pre-assembled packages SIMATIC MP 277 with WinAC
MP 2007
F
6AV6 652-3MC01-1AA0
• MP 277 8" Touch
• Electronic documentation
• Single license for MP 277 on
USB stick1)
• Standard SD Card (empty)
F
6AV6 652-3LC01-1AA0
F
6AV6 652-3PC01-1AA0
• MP 277 10" Touch
• Electronic documentation
• Single license for MP 277 on
USB stick1)
• Standard SD Card (empty)
Package MP 277 10" Key
6AV6 691-1DJ01-0AA0
6AV6 691-1DJ01-0AB0
• French
6AV6 691-1DJ01-0AC0
• Italian
6AV6 691-1DJ01-0AD0
• Spanish
6AV6 691-1DJ01-0AE0
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
User Manual
WinCC flexible Communication
• MP 277 8" Key
• Electronic documentation
• Single license for MP 277 on
USB stick1)
• Standard SD Card (empty)
Package MP 277 10" Touch
• German
• English
WinCC flexible Compact/
Standard/Advanced
User Manual
• MPI cable, 5 m (for download
and test purposes only)
Package MP 277 8" Key
Documentation (to be ordered separately)
MP 277 Operating Instructions
Consisting of:
Package MP 277 8" Touch
2
Consisting of:
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation,
on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
F
6AV6 652-3NC01-1AA0
Accessories
• MP 277 10" Key
• Electronic documentation
• Single license for MP 277 on
USB stick1)
• Standard SD Card (empty)
Accessories for supplementary
ordering
1)
B) Subject to export regulations: AL: N and ECCN: EAR99S
Can only be used for license handling
See HM Accessories
D) Subject to export regulations: AL: N and ECCN: 5D992B1
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
Siemens ST 80 · 2009
2/123
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Dimensions
All specifications in mm. Tolerance ± 1 mm.
2
240
61
6
61
352
6
SIMATIC MULTI PANEL
221
205
121
47
SIMATIC MULTI PANEL
SIEMENS
165
180
47
225
337
G_ST80_XX_00286
SIEMENS
G_ST80_XX_00284
224
MP 277 8" Touch
MP 277 8" Key
352
SIEMENS
43
205
121
10
6
20
77
G_ST80_XX_00285
309
260
MP 277 10" Touch
2/124
Siemens ST 80 · 2009
260
224
337
432
MP 277 10" Key
G_ST80_XX_00287
G_ST80_XX_00286
107
310
221
247
160
SIMATIC MULTI PANEL
SIMATIC MULTI PANEL
SIEMENS
263
55
61
47
SIMATIC MULTI PANEL
SIEMENS
483
6
289
61
325
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 270 series
SIMATIC MP 277 (incl. INOX)
■ Dimensions
■ More information
Additional information is available in the Internet under:
All specifications in mm. Tolerance ± 1 mm.
http://www.siemens.com/mp
61
325
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
247
160
263
20
G_ST80_XX_00285
309
260
2
Note:
43
SIMATIC MULTI PANEL
SIEMENS
6
MP 277 10" Touch with stainless-steel front
Siemens ST 80 · 2009
2/125
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
■ Overview
■ Benefits
2
• Like operator panels, Multi Panels (MP) are used for local
machine operation and monitoring
• Their functionality can be expanded by the installation of
additional Windows CE applications (Multi Panel and Panel
options)
• SIMATIC MP 377 devices on the basis of Windows CE
combine the rugged construction of Operator Panels with the
flexibility of PCs
• PLC functionality can be integrated directly into the MP 377
platform with Option
• Pixel-graphics 12", 15" or 19" TFT display, color (64k colors)
• MP 377 12" Touch, MP 377 15" Touch and MP 377 19" Touch:
Touch screen (analog/resistive)
MP 377 12" Key:
38 system keys, 36 user-configurable and freely inscribable
function keys (36 with LEDs)
• SIMATIC MP 377 PRO 15" Touch:
with a rugged and extremely compact aluminum housing, full
IP65 protection and thus suitable for harsh environmental
conditions.
• All interfaces, e.g. MPI, PROFIBUS DP, USB, PROFINET
(Ethernet TCP/IP), are on-board
• Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• Modular expansion possible with options such as
- Software PLC SIMATIC WinAC MP 2007
- WinCC flexible/[email protected] for communication between
different SIMATIC HMI systems
- WinCC flexible/[email protected] for remote maintenance and
servicing of machines/plants via the intranet/Internet
- WinCC flexible/OPC-Server for communication with
applications from various manufacturers
- MS Pocket Internet Explorer 6.0 (already included in the
scope of delivery)
- MS Multi Media Player (already included in the scope of
delivery)
- MS Viewer for Word, Excel and PDF files (already included in
scope of delivery)
• Reduction of service and commissioning costs through:
- Backup/restore via Ethernet (TCP/IP), USB, MPI,
PROFIBUS DP or optionally via CF/SD/Multi Media Card
- Remote download/upload for configuration and firmware
- Specific drivers can be reloaded
- Long service life of the backlighting
• Graphics library with off-the-shelf picture objects
• Can be used worldwide:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets)
- Up to 16 languages can be switched online
• Standard hardware and software interfaces for increasing
flexibility:
- CF Card Slot and SD/Multi Media Card Slot for memory
expansions, Backup/Restore
- Ethernet (TCP/IP) for central data and project management
and control link possible to SIMATIC S7
- Standard Windows storage formats (CSV) for archives and
recipes permit further processing with standard tools (e.g.
Microsoft Excel)
■ Application
The Multi Panels SIMATIC MP 377 can be used wherever machines and systems are operated and monitored directly on-site
– whether in production, process or building automation. These
are used in the most popular branches and applications and can
be expanded in their applications with the Multi Panel options,
e.g. by displaying HTML documents via the Microsoft Pocket
Internet Explorer.
Windows CE meets the basic prerequisites for application in
rough industrial environments. The diskless and fanless design
enables implementation in areas where high vibration or dust
load limits the operation of a PC. Short boot-up times make the
Multi Panels ready for operation sooner as well.
2/126
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
■ Design
• Compact design with low mounting depth
• The front is resistant to various oils, greases and standard
detergents
• Degree of protection IP65/NEMA 4x/NEMA 12 (front) or IP20
(rear)
• Plug-in terminals for 24 V DC power supply
• Interfaces:
- RS 485/RS 422 interface for process connections
(MPI, PROFIBUS DP up to 12 Mbit/s)
- USB for mouse, keyboard, printer, barcode reader, and
downloading/uploading the configuration
- Ethernet (TCP/IP) for exchanging data with a higher-level
PC, connection of a network printer and downloading/
uploading the configuration; a control link to SIMATIC S7 is
possible
• Slot for Compact Flash Card (CF Card)
• Slot for SD/Multi Media Card
• Retentive memory for WinAC MP 377 data (data, timers,
counters and bit memories)
SIMATIC MP 377 PRO 15" Touch
The MP 377 is also available in a support arm version
• All-round IP65 protection
• NEMA 4 certification
• For mounting on support arm/pedestal
• 15" touch display
• Rugged die-cast aluminum housing
• Adaptation of the device optionally from above or below
• Direct connection to support arm systems of well-known
manufacturers (e.g. Rittal, Bernstein, Rose, Rolec)
• Supports the globally established VESA 75/VESA 100
standard
■ Function
• Display and modification of process parameters
• Function keys (for MP 377 12" Keys)
for direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on function keys. The
function keys can be used directly as PROFIBUS DP input
peripherals.
• Process display:
- Vector graphics (various line and surface objects)
- Dynamic positioning and dynamic showing/hiding of objects
- Pixel-graphic displays, curves and bar displays
- Presentation of up to 8 curves in a curve field;
curve graphics with paging and zoom functions for access
to the history and for flexible selection of the presentation
time;
reading ruler for determining the current values and
displaying them in a table
- Extensive symbol libraries (SIMATIC HMI symbol library)
- Screen objects: Slider, gauge, clock
- Cyclic function processing using timers
• Multiplex function for variables
• Signaling system
- Bit messages and analog messages (limit value messages)
as well as the ALARM_S message frame procedure for
SIMATIC S7 and SIMOTION
- Freely-definable message classes (e.g. status/fault
messages) for definition of acknowledgment response and
display of message events
- Status and fault messages with message history
- Pre-configured message image, message window and
message line
• Archiving of messages and process values (on CF/SD/
MultiMedia card/USB, etc., or network drives over Ethernet)
- Various archive types: Circular and sequential archives
- Storage of archive data in standard Windows format (CSV)
- Online evaluation of process value archives through trend
curves
- External processing using standard tools (MS Excel and
MS Access) is possible
• Message log and shift log
• Print functions (see "Recommended printers")
• Language switching
16 online languages, 32 configuration languages incl. Asiatic
and Cyrillic character sets
• Recipe management
- With additional data storage (on CF/SD/multimedia
card/USB, etc.)
- Online/offline processing on the panel
- Storage of recipe data in standard Windows format (CSV)
- External processing using standard tools (Microsoft Excel
and Access) is possible
• Programming device functionality STATUS/ FORCE-VAR in
conjunction with SIMATIC S5 and SIMATIC S7
• Display selection from the PLC
supports operator prompting from the PLC
• Presentation of HTML documents with MS Pocket Internet
Explorer
• Visual Basic Script, flexibility thanks to the implementation of
new functions including linking to variables (comparison
operations, loops, etc.)
• Help texts
for process screens, messages and variables
• Arithmetic functions
• Limit value monitoring
for reliable process control of inputs and outputs
• Permanent window;
- Fixed area of screen for outputting non-screen-specific
information (e.g. important process values, date and time)
- Permanent window expanded by template concept for
creating screen templates
• Simple maintenance and configuration thanks to:
- Saving and loading (Backup/Restore) configurations,
operating system, data records and firmware on an optional
memory card (CF/SD/Multi Media Card) or via Ethernet
- Backup and restoration of the configuration, operating
system, data records and firmware on a PC
- Configuration download/upload via Ethernet/USB/MPI/
PROFIBUS DP/modem and CF or SD/Multi Media Card
- Automatic transfer identification
- Configuration simulation directly on the configuration
computer
Siemens ST 80 · 2009
2/127
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
■ Function (continued)
2
• Import/export of all texts incl. messages in CSV format for
translation using standard text processing programs
• Centrally modifiable project-specific faceplates
• User administration (security)
- User-oriented access protection according to requirements
of specific sectors
- Authentication with user ID and password
- User-group-specific rights
• Visual Basic Runtime object model
• Service functions (opt. with "WinCC flexible /[email protected]")
- Email generation
- Remote control of the SIMATIC HMI system based on
Internet Explorer
- Web server with status HTML pages and control functions
• Client/server functions (optionally with "WinCC flexible
/[email protected]")
- Remote operation and monitoring from other SIMATIC HMI
systems
- Plant-wide requests for information and archiving of process
data
■ Integration
The MP 377 can be connected to:
• SIMATIC S7-200/-300/-400
• SIMATIC WinAC Software/Slot PLC
• Ethernet communication with SIMATIC S7
• SIMATIC S5
• SIMATIC 505
• SINUMERIK
• SIMOTION
• Non-Siemens PLCs:
- Allen Bradley
- Mitsubishi
- Telemecanique
- LG GLOFA GM
- Modicon
- GE-Fanuc
- Omron
• Over Ethernet (TCP/IP) to a higher-level PC, network printer
• Multi-protocol capability
• OPC XML server (optional with "WinCC flexible /OPC server")
• http communication with other SIMATIC HMI systems
(optional with "WinCC flexible/[email protected]")
• SINUMERIK
(optionally with "SINUMERIK HMI copy license WinCC flexible
CE"; "SINUMERIK HMI engineering package WinCC flexible"
is additionally required for configuration)
Note:
For further information, see "System interfaces"
2/128
Siemens ST 80 · 2009
■ Configuration
The configuration is done with the SIMATIC WinCC flexible
Standard or Advanced engineering software (see HMI
Software/SIMATIC WinCC flexible engineering software).
Projects created with ProTool can be transferred to WinCC
flexible.
Applications/Options
• WinCC flexible /ProAgent
Targeted and fast process error diagnostics in systems and
machines for SIMATIC S7 and SIMATIC HMI (see HMI
Software/process diagnostics software SIMATIC ProAgent)
• WinAC MP 2007 Software PLC for Multi Panels.
The I/O can be connected using PROFIBUS DP.
• WinCC flexible /[email protected];
Remote operation and monitoring as well as communication
between different SIMATIC HMI systems (see HMI Software/runtime software SIMATIC WinCC flexible/WinCC
flexible RT options)
• WinCC flexible/[email protected];
Remote maintenance and servicing of machines/plants via the
intranet/Internet (see HMI Software/runtime software SIMATIC
WinCC flexible/WinCC flexible RT options)
• WinCC flexible/OPC server
Communication with applications (e.g. MES, ERP,
or applications in the Office sector) from various
manufacturers (see HMI Software/runtime software SIMATIC
WinCC flexible/WinCC flexible RT options)
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
■ Technical specifications
SIMATIC MP 377
12" Touch
12" Key
15" Touch
19" Touch
PRO 15" Touch
Supply voltage
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
permissible range
+19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC
Supply voltage
Memory
Type of storage
Type
Flash / RAM
Memory usable
for project data/Options
12288 KB / 12288 KB 12288 KB / 12288 KB 12288 KB / 12288 KB 12288 KB / 12288 KB 12288 KB / 12288 KB
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Time
Clock
• Type
Hardware clock,
battery backed,
synchronizable
Hardware clock,
battery backed,
synchronizable
Hardware clock,
battery backed,
synchronizable
Hardware clock,
battery backed,
synchronizable
Hardware clock,
battery backed,
synchronizable
Yes
Yes
Yes
Yes
Yes
WinCC flexible
Standard Version
2007 or higher (to be
ordered separ.)
WinCC flexible
Standard Version
2007 or higher (to be
ordered separ.)
WinCC flexible
Standard Version
2007 or higher (to be
ordered separ.)
WinCC flexible
Standard Version
2007 or higher (to be
ordered separ.)
WinCC flexible
Standard Version
2007 or higher (to be
ordered separ.)
Protocols
Protocols (terminal link)
• [email protected]
Configuration
Configuration tool
Display
Display type
TFT, 65 536 Colors
TFT, 65 536 Colors
TFT, 65 536 Colors
TFT, 65 536 Colors
TFT, 65 536 Colors
Size
12.1" (246 mm x
184.5 mm)
12.1" (246 mm x
184.5 mm)
15" (304.1 mm x
228.1 mm)
19" (376.3 mm x
301.1 mm)
15" (304.1 mm x
228.1 mm)
Resolution
(W x H in pixel)
800 x 600
800 x 600
1024 x 768
1280 x 1024
1024 x 768
MTBF backlighting
(at 25 °C)
about 50,000 hours
about 50,000 hours
about 50,000 hours
about 50,000 hours
about 50,000 hours
Touch screen
Membrane keyboard Touch screen
Touch screen
Touch screen
Operating mode
Operating
elements
36 function keys,
36 with LEDs
Function keys, programmable
System keys
38
Touchscreen
analog, resistive
analog, resistive
analog, resistive
analog, resistive
Numeric/alphabetical input
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Yes / Yes
Connection
for mouse/keyboard/barcode
reader
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
Max. permissible tilt angle
without external ventilation
+/- 35°
+/- 35°
+/- 35°
+/- 35°
+/- 35°
Max. relative humidity (in %)
90%
90%
90%
90%
90%
• Operation (vertical install.)
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Ambient conditions
Temperature
Siemens ST 80 · 2009
2/129
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
■ Technical specifications (continued)
SIMATIC MP 377
12" Touch
12" Key
15" Touch
19" Touch
PRO 15" Touch
Front
IP65, NEMA 4,
NEMA 12
(when installed)
IP65, NEMA 4,
NEMA 12
(when installed)
IP65, NEMA 4,
NEMA 12
(when installed)
IP65, NEMA 4,
NEMA 12
(when installed)
IP65
Rear
IP20
IP20
IP20
IP20
IP65
CE, FM Class I Div. 2, CE, cULus,
cULus, EX-Zone 22, C-TICK, NEMA 4,
C-TICK, NEMA 4,
NEMA 12
NEMA 12
CE, FM Class I Div. 2,
cULus, EX-Zone 22,
C-TICK, NEMA 4,
NEMA 12
FM Class I Div. 2,
cULus, EX-Zone 22,
C-TICK, NEMA 4,
NEMA 12
CE, cULus
Printer, card reader,
barcode reader
Printer, card reader,
barcode reader
Printer, card reader,
barcode reader
Printer, card reader,
barcode reader
Degree of protection
2
Certifications & Standards
Certifications
I/O Options
I/O devices
Printer, card reader,
barcode reader
Type of output
LED colors
Red, green
Acoustics
WAV sound signal
WAV sound signal
WAV sound signal
WAV sound signal
WAV sound signal
Interfaces
1 x RS422,
1 x RS485
1 x RS422,
1 x RS485
1 x RS422,
1 x RS485
1 x RS422,
1 x RS485
1 x RS422,
1 x RS485
CF card slot
1 x CF card slot
1 x CF card slot
1 x CF card slot
1 x CF card slot
1 x CF card slot
Multi Media Card slot
1 x Multi Media
Card slot
1 x Multi Media
Card slot
1 x Multi Media
Card slot
1 x Multi Media
Card slot
1 x Multi Media
Card slot
USB
2 x USB
2 x USB
2 x USB
2 x USB
2 x USB
Ethernet
2 x Ethernet (RJ45)
2 x Ethernet (RJ45)
2 x Ethernet (RJ45)
2 x Ethernet (RJ45)
2 x Ethernet (RJ45)
Windows CE
Windows CE
Windows CE
Windows CE
Windows CE
Applications/options
ProAgent, Internet
Explorer, Soft-PLC,
Word Viewer, Excel
Viewer, PDF Viewer,
[email protected],
[email protected]
ProAgent, Internet
Explorer, Soft-PLC,
Word Viewer, Excel
Viewer, PDF Viewer,
[email protected],
[email protected]
ProAgent, Internet
Explorer, Soft-PLC,
Word Viewer, Excel
Viewer, PDF Viewer,
[email protected],
[email protected]
ProAgent, Internet
Explorer, Soft-PLC,
Word Viewer, Excel
Viewer, PDF Viewer,
[email protected],
[email protected]
ProAgent, Internet
Explorer, Soft-PLC,
Word Viewer, Excel
Viewer, PDF Viewer,
[email protected],
[email protected]
Number of Visual Basic scripts
100
100
100
100
100
Task planner
Yes
Yes
Yes
Yes
Yes
Help system
Yes
Yes
Yes
Yes
Yes
Status/control
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
with SIMATIC S7
Interfaces
Operating systems
Operating system
Functionality under WinCC
flexible
Message system
• Number of messages
4 000
4 000
4 000
4 000
4 000
• Bit messages
Yes
Yes
Yes
Yes
Yes
• Analog messages
Yes
Yes
Yes
Yes
Yes
• Message buffer
Ring buffer
(n x 1024 entries),
retentive,
maintenance-free
Ring buffer
(n x 1024 entries),
retentive,
maintenance-free
Ring buffer
(n x 1024 entries),
retentive,
maintenance-free
Ring buffer
(n x 1024 entries),
retentive,
maintenance-free
Ring buffer
(n x 1024 entries),
retentive,
maintenance-free
Recipes
• Recipes
500
500
500
500
500
• Data records per recipe
1 000
1 000
1 000
1 000
1 000
• Entries per data record
1000
1000
1000
1000
1000
• Recipe memory
128 kByte integrated 128 kByte integrated 128 kByte integrated 128 kByte integrated 128 kByte integrated
Flash, expandable
Flash, expandabler
Flash, expandable
Flash, expandable
Flash, expandable
2/130
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
■ Technical specifications (continued)
SIMATIC MP 377
12" Touch
12" Key
15" Touch
19" Touch
PRO 15" Touch
• Process images
500
500
500
500
500
• Variables
4 096 1)
4 096 1)
4 096 1)
4 096 1)
4 096 1)
• Limit values
Yes
Yes
Yes
Yes
Yes
• Multiplexing
Yes
Yes
Yes
Yes
Yes
Functionality under WinCC
flexible (continued)
2
Number of process images
Image elements
• Text objects
30,000 text elements 30,000 text elements 30,000 text elements 30,000 text elements 30,000 text elements
• Graphics object
Bit maps, icons,
vector graphics
Bit maps, icons,
vector graphics
Bit maps, icons,
vector graphics
Bit maps, icons,
vector graphics
Bit maps, icons,
vector graphics
• dynamic objects
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Diagrams, bar
graphs, sliders,
analog display,
invisible buttons
Lists
• Text lists
500
500
500
500
500
• Graphics list
500
500
500
500
500
• Libraries
Yes
Yes
Yes
Yes
Yes
Archiving
• Number of archives per project 50
50
50
50
50
• Number of measuring points
per project
50
50
50
50
50
• Number of entries per archive
50 000
50 000
50 000
50 000
50 000
• Archiving types
Sequence archive,
short-term archive,
alarm log, process
value archive
Sequence archive,
short-term archive,
alarm log, process
value archive
Sequence archive,
short-term archive,
alarm log, process
value archive
Sequence archive,
short-term archive,
alarm log, process
value archive
Sequence archive,
short-term archive,
alarm log, process
value archive
• Memory location
CF card, SD/MMC
card, Ethernet, USB
memory stick
CF card, SD/MMC
card, Ethernet, USB
memory stick
CF card, SD/MMC
card, Ethernet, USB
memory stick
CF card, SD/MMC
card, Ethernet, USB
memory stick
CF card, SD/MMC
card, Ethernet, USB
memory stick
• Data storage format
CSV file, readable,
e.g. with MS Excel,
MS Access
CSV file, readable,
e.g. with MS Excel,
MS Access
CSV file, readable,
e.g. with MS Excel,
MS Access
CSV file, readable,
e.g. with MS Excel,
MS Access
CSV file, readable,
e.g. with MS Excel,
MS Access
• external evaluation
Readable, e.g. with
MS Excel, MS
Access, etc.
Readable, e.g. with
MS Excel, MS
Access, etc.
Readable, e.g. with
MS Excel, MS
Access, etc.
Readable, e.g. with
MS Excel, MS
Access, etc.
Readable, e.g. with
MS Excel, MS
Access, etc.
• Size of archive
depending on free
memory on ext.
card/stick or on free
hard disk space via
network drive
depending on free
memory on ext.
card/stick or on free
hard disk space via
network drive
depending on free
memory on ext.
card/stick or on free
hard disk space via
network drive
depending on free
memory on ext.
card/stick or on free
hard disk space via
network drive
depending on free
memory on ext.
card/stick or on free
hard disk space via
network drive
• Online evaluation
Using trends
Using trends
Using trends
Using trends
Using trends
Security
• Number of user groups
50
50
50
50
50
• Passwords exportable
Yes
Yes
Yes
Yes
Yes
• Number of user rights
32
32
32
32
32
• CF card
Yes
Yes
Yes
Yes
Yes
• Multi Media Card
Yes
Yes
Yes
Yes
Yes
Data medium support
Recording
• Recording/Printing
Alarms, report
Alarms, report
Alarms, report
Alarms, report
Alarms, report
(shift report),
(shift report),
(shift report),
(shift report),
(shift report),
color print, hardcopy color print, hardcopy color print, hardcopy color print, hardcopy color print, hardcopy
• Printer driver
ESC/P2, PCL3/PCL6
ESC/P2, PCL3/PCL6
ESC/P2, PCL3/PCL6
ESC/P2, PCL3/PCL6
ESC/P2, PCL3/PCL6
US American
(English)
US American
(English)
US American
(English)
US American
(English)
US American
(English)
Fonts
• Keyboard fonts
1)
WinCC flexible 2008 or higher
Siemens ST 80 · 2009
2/131
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
■ Technical specifications (continued)
SIMATIC MP 377
2
12" Touch
12" Key
15" Touch
19" Touch
PRO 15" Touch
Functionality under WinCC
flexible (continued)
Languages
• Online languages
16
16
16
16
16
• Configuration languages
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
D, GB, F, I, E, CHN
"traditional", CHN
"simplified", DK, FIN,
GR, J, KP / ROK, NL,
N, PL, P, RUS, S,
CZ / SK, TR, H
• Fonts
Tahoma, Arial,
Courier New, symbol
languages, 4 additional character sets
can be loaded,
all freely scalable
Tahoma, Arial,
Courier New, symbol
languages, 4 additional character sets
can be loaded,
all freely scalable
Tahoma, Arial,
Courier New, symbol
languages, 4 additional character sets
can be loaded,
all freely scalable
Tahoma, Arial,
Courier New, symbol
languages, 4 additional character sets
can be loaded,
all freely scalable
Tahoma, Arial,
Courier New, symbol
languages, 4 additional character sets
can be loaded,
all freely scalable
MPI/PROFIBUS DP,
serial, USB, Ethernet, by means of
external storage
medium, automatic
transfer recognition
MPI/PROFIBUS DP,
serial, USB, Ethernet, by means of
external storage
medium, automatic
transfer recognition
MPI/PROFIBUS DP,
serial, USB, Ethernet, by means of
external storage
medium, automatic
transfer recognition
MPI/PROFIBUS DP,
serial, USB, Ethernet, by means of
external storage
medium, automatic
transfer recognition
MPI/PROFIBUS DP,
serial, USB, Ethernet, by means of
external storage
medium, automatic
transfer recognition
S5, S7-200, S7-300/
400, TI 505, Win AC,
PC (TCP/IP),
SINUMERIK,
SIMOTION,
Allen Bradley (DF1),
Allen Bradley
(DF485), Mitsubishi
(FX), OMRON
(LINK/Multilink),
Modicon (Modbus),
see "System
interfaces"
S5, S7-200, S7-300/
400, TI 505, Win AC,
PC (TCP/IP),
SINUMERIK,
SIMOTION,
Allen Bradley (DF1),
Allen Bradley
(DF485), Mitsubishi
(FX), OMRON
(LINK/Multilink),
Modicon (Modbus),
see "System
interfaces"
S5, S7-200, S7-300/
400, TI 505, Win AC,
PC (TCP/IP),
SINUMERIK,
SIMOTION,
Allen Bradley (DF1),
Allen Bradley
(DF485), Mitsubishi
(FX), OMRON
(LINK/Multilink),
Modicon (Modbus),
see "System
interfaces"
S5, S7-200, S7-300/
400, TI 505, Win AC,
PC (TCP/IP),
SINUMERIK,
SIMOTION,
Allen Bradley (DF1),
Allen Bradley
(DF485), Mitsubishi
(FX), OMRON
(LINK/Multilink),
Modicon (Modbus),
see "System
interfaces"
S5, S7-200, S7-300/
400, TI 505, Win AC,
PC (TCP/IP),
SINUMERIK,
SIMOTION,
Allen Bradley (DF1),
Allen Bradley
(DF485), Mitsubishi
(FX), OMRON
(LINK/Multilink),
Modicon (Modbus),
see "System
interfaces"
Yes
Yes
Yes
Yes
Yes
Front of enclosure (W x H) in mm 335 x 275
483 x 310
400 x 310
483 x 400
400 x 310
Mounting cutout/Device depth
(W x H/D) in mm
310 x 248 / 72
450 x 290 / 59
367 x 289 / 72
449 x 379 / 75
367 x 289 / 72
3.8 kg
5.5 kg
4.7 kg
7.7 kg
4.7 kg
Transfer (Upload/Download)
• Transfer of configuration
Process coupling
• Connection to controller
Expandability/openness
• Open Platform Program
Dimensions
Weights
Weight
2/132
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
■ Ordering data
Order No.
SIMATIC MP 377
Multi Panel (including installation
accessories) with
• 12" color TFT display, Touch
Order No.
Complete pre-assembled packages SIMATIC MP 377 with WinAC
MP 2007 (continued)
Package MP 377 15" Touch
F
6AV6 644-0AA01-2AX0
• 12" color TFT display, keyboard F
6AV6 644-0BA01-2AX1
• 15" color TFT display, Touch
F
6AV6 644-0AB01-2AX0
• 19" color TFT display, Touch
F
6AV6 644-0AC01-2AX0
• MP 377 15" Touch
• Single license for MP 377 on
USB stick2)
• Standard Multimedia Card
(empty)
6AV6 644-2AB01-2AX0
Package MP 377 19" Touch1)
• PRO 15" color TFT display,
Touch 1)
Configuring
with SIMATIC WinCC flexible
Configuration set MP 377
D
6AV6 622-0BA01-0AA0
Consisting of:
2
F
6AV6 652-4HC01-2AA0
• MP 377 19" Touch
• Single license for MP 377 on
USB stick2)
• Standard Multimedia Card
(empty)
When configuration with
WinCC flexible
• Documentation DVD, 5 lang.
(English, French, German,
Italian, Spanish)
see HMI Software
• WinCC flexible/ProAgent
• WinCC flexible/[email protected]
• RS 232 cable (5 m)
• WinCC flexible/[email protected]
• MPI cable, 5 m (for download
and test purposes only)
• WinCC flexible/OPC Server
• WinCC flexible/Audit
Starter packages
F
6AV6 652-4FA01-0AA0
• WinAC MP 2007/Software PLC
Documentation (to be ordered separately)
COMPRISING:
MP 377 Operating Instructions
• SIMATIC MP 377 12" Touch
• SIMATIC WINCC flexible
STANDARD 2008
• SIMATIC HMI Manual Collection
• Voucher for Software Update
Service for 1 year
• MPI cable, 5 m (for download
and test purposes only)
SIMATIC MP 377 15" Touch
Starter Package
6AV6 652-4GC01-2AA0
Applications/Options
• WinCC flexible Standard
engineering software
SIMATIC MP 377 12" Touch
Starter Package
F
F
6AV6 652-4GA01-0AA0
• German
6AV6 691-1DR01-0AA0
• English
6AV6 691-1DR01-0AB0
• French
6AV6 691-1DR01-0AC0
• Italian
6AV6 691-1DR01-0AD0
• Spanish
6AV6 691-1DR01-0AE0
WinCC flexible Compact/
Standard/Advanced
User Manual
• German
6AV6 691-1AB01-3AA0
COMPRISING:
• English
6AV6 691-1AB01-3AB0
• SIMATIC MP 377 15" Touch
• SIMATIC WINCC flexible
STANDARD 2008
• SIMATIC HMI Manual Collection
• Voucher for Software Update
Service for 1 year
• MPI cable, 5 m (for download
and test purposes only)
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
6AV6 691-1AB01-3AE0
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
Complete pre-assembled packages SIMATIC MP 377 with
WinAC MP 2007
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Package MP 377 12" Touch
User Manual
WinCC flexible Communication
F
6AV6 652-4FC01-2AA0
• MP 377 12" Touch
• Single license for MP 377 on
USB stick2)
• Standard Multimedia Card
(empty)
Package MP 377 12" Key
Electronic documentation,
on DVD
F
6AV6 652-4EC01-2AA0
• MP 377 12" Key
• Single license for MP 377 on
USB stick2)
• Standard Multimedia Card
(empty)
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
Accessories
Accessories for supplementary
ordering
See HM Accessories
1)
An adapter set is required for mounting. See Chapter 8
"Fully enclosed HMI units".
B) Subject to export regulations: AL: N and ECCN: EAR99S
2)
For license handling only
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
D) Subject to export regulations: AL: N and ECCN: 5D992B1
Siemens ST 80 · 2009
2/133
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panels — 370 series
SIMATIC MP 377
38
20
■ Dimensions
310
73
288
92
310
288
2
400
32
483
30
6
10
72
59
366
448
295
G_ST80_XX_00311
300
G_ST80_XX_00309
58
35
MP 377 15" Touch
MP 377 12" Key
53
310
247
275
17
400
30
335
6
72
124
400
378
34
483
11
75
447
295
G_ST80_XX_00312
54
MP 377 19" Touch
2/134
67,85
G_ST80_XX_00310
MP 377 PRO 15"
77
MP 377 12" Touch
Siemens ST 80 · 2009
G_ST80_XX_00351
98,5
309
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panel options
SIMATIC WinAC MP
■ Overview
Service concept
All data, operating systems, HMI data, PLC data, archives, recipes, licenses, etc., can be stored on a standard memory
medium1) with the press of a button. The only exception is the
content of the M-RAM memory (current status of bit memories,
timers, counters and data blocks). This is not necessary for the
restore procedure, however. The function Backup/Restore therefore offers an extensive and perfect service concept.
1)
Memory media released by Siemens are preferred
■ Design
The WinAC MP is functionally very closely based on a hardware
CPU and is a real alternative for price-sensitive applications that
require the stability and ruggedness of a hardware solution.
The functions of the WinAC MP are integrated directly in WinCC
flexible and STEP 7 during the installation on the configuration
computer. This ensures that every user can freely configure and
if necessary block access to, for example, the start/stop button
or the LEDs in the SIMATIC HMI project. Of course a prefabricated user interface will be delivered as an example.
• WinAC MP, the software PLC based on Windows CE
• An optimized version is available for all current MP platforms
• The economical solution for all applications in combination
with a rugged hardware platform
• Ideal for tasks on the machine level, saves space and costs
• Best service concept, backup/restore of all data on a standard
SD card, standard Multi Media Card or standard USB stick
■ Application
The WinAC MP is a new, rugged software PLC for all SIMATIC
HMI Multi Panel platforms. It has been developed for smaller and
medium-sized applications that do not depend on the last millisecond and costs are in the forefront. The WinAC uses proven
tools such as STEP 7 (V5.4/SP1 or higher) and WinCC flexible
(Standard or higher as of version 2007). This makes it possible
to upgrade or switch without any extra training for new tools. The
operator interface of the WinAC MP is included. Users can thus
copy the required operator controls into their project. Of course,
all operator functions of the WinAC MP are available in the function list after installing the option on the configuration computer
in WinCC flexible (as of version 2007)! The peripherals are connected via PROFIBUS DP. Here, ET I/O modules up to technology modules are available.
Processing WinCC flexible projects
Retentivity of the timers, counters, flags and data blocks is ensured by the Multi Panel hardware as with a hardware CPU. A
UPS is not required.
The time distribution on the Multi Panel between WinAC MP and
HMI Runtime is predefined and can be adapted to the relevant
application.
For time-critical applications, an OB35 time block (min. clockpulse rate 1 ms) is available for processing the time-critical signals. Direct responses can be integrated into the process with
OB40 (I/O alarms) as well. For service and optimization purposes, there are diverse functions available such as a histogram
for cycle times that can be embedded in the user’s SIMATIC HMI
project.
Versions
Different WinAC MP versions are available. The versions define
new CPU performance classes.
• The versions are optimized for the Multi Panel platforms.
These versions, namely WinAC MP 177, 277 to 377 are based
roughly on the hardware CPUs 314, 315 and 317. They have
similar quantity frameworks but are not a 1:1 copies.
• All limit values, e.g. number of bit memories, DBs, FCs, I/Os,
etc., are preset as with a hardware CPU and cannot be
changed by the user. Detailed technical data is provided in
chapter "Technical Data".
WinCC flexible projects are processed with WinCC flexible 2007
(as of the Standard version) and STEP 7 V5.4 from SP 1.
If WinCC flexible is integrated and operated in STEP 7, a common database offers the highest degree of programming comfort, which ensures an optimal continuity when creating your applications. Program faults are therefore avoided from the outset.
Siemens ST 80 · 2009
2/135
2
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panel options
SIMATIC WinAC MP
■ Function
2
I/Os
The principle of operation and the instruction set of the WinAC
MP is basically identical to a hardware CPU. The settings for the
WinAC MP-specific parameters are implemented by means of
the Hardware Config. Since WinAC MP and HMI application
share a processor, however, there is a special response regarding the timing of the WinAC MP. All PLC commands are more
quickly processed multiple times faster than on a hardware CPU,
but this is required to created time reserves for the HMI
application. The potential for time optimization improves with
larger PLC programs. As of WinAC MP 2008, a fixed enabling
time must be set for the HMI. The default for this time is 50 ms.
Users can change this time to achieve optimal performance of
the application.
In practice, this means an OB1 executes faster on a soft CPU
and the time gained can be used for HMI Runtime. Another
advantage of the WinAC MP is that the HMI application can
always be interrupted by WinAC MP time and process alarms.
Fast key response times can also be used with the implemented
function "DP direct keys" with the WinAC MP. This provides
another performance advantage of the WinAC MP.
■ Integration
Installation/licensing
The installation conceivably easy. With ProSave (integrated in
WinCC flexible), the WinAC MP option is simply loaded onto the
panel. The WinAC MP then reacts similarly to an integrated
hardware CPU.
A license key is required for the WinAC MP. The license key is always provided together with the WinAC MP. The license key is
located on a standard USB stick and must be loaded separately
on the Multi Panel after installation of the WinAC MP option.
Software bus
In addition to WinAC MP, a software bus is installed at the same
time on a SIMATIC HMI Multi Panel. This is required to coordinate
communication between the SIMATIC HMI application and
WinAC MP. The software bus also includes an entire range of advantages for the user. For example, diverse upload and download routing mechanisms are supported. This enables, among
other things, updating of SIMATIC products that are connected
with the PROFIBUS DP side of the Multi Panel, even if the programming device is connected on the PROFINET side (Ethernet/LAN). Similar connections are naturally also possible for
STEP7.
2/136
Siemens ST 80 · 2009
The I/O can be connected via PROFIBUS DP. Standard components such as ET200 and the modules that can be used within
are utilized. Diverse technological components can also be
used with the ET200M in this constellation. In addition to normal
standard ET I/Os, the following FM modules are released on the
PROFIBUS:
• FM 350-1 counter module
• FM 350-2 counter module (8-channel)
• FM 351 positioning module
• FM 352 cam controller
• FM 353 positioning module for stepper motors
• FM 354 positioning module for servo motors
• FM 355 closed-loop control module
• FM 355-2 temperature control module
• FM 352-5 high-speed Boolean processor
■ Programming
Programming in accordance with IEC 6 1131-3 and configuration of WinAC MP are done with STEP 7 V5.4/SP1 (or higher) and
the SIMATIC engineering tools for production technology. Thus
all SIMATIC programming languages for WinAC MP are available as well.
The SIMATIC programming languages comply with the standard
DIN EN 6.1131-3. This reduces the familiarization and training
overhead. CFC, SCL and S7-Graf are also supported.
In addition, program modules that have been programmed for
SIMATIC S7 hardware CPUs can be reused in WinAC MP without
modifications as long as they were not designed for special features of a SIMATIC S7 CPU.
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panel options
SIMATIC WinAC MP
■ Technical specifications
WinAC MP 277
WinAC MP 377
Memory
Type of storage
- integrated
256 Kibyte
512 Kibyte
- expandable
No
No
1.2 MByte
1.2 MByte
• Load memory
CPU/blocks
DB
• Number, max.
WinAC MP 377
• Number
256
512
• of which remanent without
battery
- adjustable
Yes
Yes
- lower limit
0
0
- upper limit
256
512
• Remanence
- adjustable
Yes
Yes
0
0
10 ms
10 ms
9 990 s
9 990 s
1 024;
FBs+FCs+DBs=
1024
2 048;
FBs+FCs+DBs=
2048
64 Kibyte
64 Kibyte
1 024;
FBs+FCs+DBs=
1024
2 048;
FBs+FCs+DBs=
2048
IEC timer
64 Kibyte
64 Kibyte
• present
1 024;
FBs+FCs+DBs=
1024
2 048; * max.
2048 total
64 Kibyte
64 Kibyte
• Number, max.
18
18
• Size, max.
64 Kibyte
64 Kibyte
• Size, max.
FB
• Number, max.
• Size, max.
FC
• Number, max.
• Size, max.
2
S7 times
• RAM
- integrated RAM, max.
WinAC MP 277
Times/counters and their
remanence (continued)
OB
- preset
• Time range
- lower limit
- upper limit
Yes; SFB3, SFB4, Yes; SFB3, SFB4,
SFB5
SFB5
Data areas and their
remanence
Retentive data area in total
(incl. times, counters, flags),
max.
128 Kibyte
256 Kibyte
• Number, max.
2 Kibyte
4 Kibyte
• Remanence available
Yes
Yes
Flag
Nesting depth
Data blocks
• per priority class
8
16
• Number, max.
1 024
2 048
• additional within an error OB
2
2
• Size, max.
64 Kibyte
64 Kibyte
16 384 byte;
Max. for all
priority classes
16 384 byte;
Max. for all
priority classes
Local data
Times/counters and their
remanence
• per priority class, max.
S7 counter
• Number
• of which remanent without
battery
- adjustable
256
512
Address area
I/O address area
Yes
Yes
• Inputs
4 Kibyte
8 Kibyte
- lower limit
0
0
• Outputs
4 Kibyte
8 Kibyte
- upper limit
256
512
Process image
• Remanence
- adjustable
• Inputs
2 Kibyte
2 Kibyte
Yes
Yes
• Outputs
2 Kibyte
2 Kibyte
8
8
• Inputs, adjustable
2 Kibyte
2 Kibyte
• Outputs, adjustable
2 Kibyte
2 Kibyte
- preset
• Counting range
- lower limit
- upper limit
0
0
• Inputs, preset
512 byte
512 byte
999
999
• Outputs, preset
512 byte
512 byte
• consistent data, max.
32 byte
32 byte
1
1
• Number
8
8
• Number/Number range
0 to 7
0 to 7
IEC counter
• present
Yes; SFB0, SFB1, Yes; SFB0, SFB1,
SFB2
SFB2
Hardware config.
Number of DP masters
• integrated
Time
Operating hours counter
Siemens ST 80 · 2009
2/137
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panel options
SIMATIC WinAC MP
■ Technical specifications (continued)
WinAC MP 277
WinAC MP 377
S7 message functions
2
Process diagnostic messages
Yes
Yes
WinAC MP 377
8
8
DP master
Test commissioning functions
• Number of connections, max.
Status/control
• Services
• Status/control variable
WinAC MP 277
1st interface
Yes; Status
blocks, single
step, breakpoint
Yes; Status
blocks, single
step, breakpoint
- PG/OP communication
Yes
Yes
- Routing
Yes
Yes
Forcing
- Global data communication
No
No
• Forcing
- S7 basic communication
No
No
- S7 communication
Yes
Yes
- equidistance support
No
No
1 000; preset 120 1 000; preset 120
- SYNC/FREEZE
Yes
Yes
Yes
Yes
- Activation/deactivation of
DP slaves
Yes
Yes
- DPV1
16
32
No
No
Yes
Yes
Diagnostic buffer
• present
• Number of entries, max.
• adjustable
Communication functions
Number of logical connections
(also in network), max.
Yes
Yes
• Transmission speeds, max.
12 000 kBit/s
12 000 kBit/s
32
32
PG/OP communication
Yes
Yes
• Number of DP slaves, max.
Routing
Yes
Yes
• Address area
Global data communication
- Inputs, max.
2.048 Kibyte
8.192 Kibyte
• supported
- Outputs, max.
2.048 Kibyte
8.192 Kibyte
• STEP 7
Yes
Yes
• WinCC flexible Compact
No
No
• WinCC flexible Standard
Yes
Yes
• WinCC flexible Advanced
Yes
Yes
No
No
CPU/programming
S7 basic communication
• supported
No
No
S7 communication
• supported
Yes; PUT/GET,
without
BSEND/BRCV
Yes
• as server
Yes
Yes
• as client
Yes
Yes
• Useful data per job, max.
0.48 Kibyte
0.48 Kibyte
Number of connections
• overall
Configuration software
Programming language
• LAD
Yes
Yes
• FUP
Yes
Yes
• AWL
Yes
Yes
16; (DP max. 8,
rest PN)
32; (DP max. 8,
rest PN)
14; DP max. 6,
rest PN
30; DP max. 6,
rest PN
• adjustable
Yes
Yes
• preset
6 000 ms
6 000 ms
- reserved for PG
communication
1
1
Operating systems
- reserved for OP
communication
1
1
Yes
Yes
• usable for routing
6
1; English
1; English
- of which static
Cycle time monitoring
Operating system
• Windows CE
16
Online languages
Number
2/138
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
Multi Panel options
SIMATIC WinAC MP
■ Ordering data
WinAC MP, version
WinAC MP 2772)
Order No.
B
6ES7 671-5EF00-0YA0
incl. a single license for MP 277
on USB stick1) and electronic
documentation
WinAC MP, version
WinAC MP 3772)
B
6ES7 671-7EG00-0YA0
incl. a single license for MP 377
on USB stick1) and electronic
documentation
F
6AV6 652-3MC01-1AA0
• MP 277 8" Touch
• WinAC MP Version 277
• Electronic documentation
• Single license for MP 277 on
USB stick1)
• Standard SD card 256 MB
(empty)
Package MP 277 8" Key
F
6AV6 652-3LC01-1AA0
Package MP 277 10" Touch
6AV6 652-3PC01-1AA0
F
6AV6 652-3NC01-1AA0
• MP 277 10" Touch
• WinAC MP Version 277
• Electronic documentation
• Single license for MP 277 on
USB stick1)
• Standard SD card 256 MB
(empty)
Package MP 277 10" Key
2
F
6AV6 652-4EC01-2AA0
F
6AV6 652-4GC01-2AA0
F
6AV6 652-4HC01-2AA0
• MP 377 15" Touch
• WinAC MP Version 377
• Electronic documentation
• Single license for MP 377 on
USB stick1)
• Standard SD card 256 MB
(empty)
Package MP 377 19" Touch
F
6AV6 652-4FC01-2AA0
• MP 377 12" Key
• WinAC MP Version 377
• Electronic documentation
• Single license for MP 377 on
USB stick1)
• Standard SD card 256 MB
(empty)
Package MP 377 15" Touch
• MP 277 8" Key
• WinAC MP Version 277
• Electronic documentation
• Single license for MP 277 on
USB stick1)
• Standard SD card 256 MB
(empty)
F
• MP 377 12" Touch
• WinAC MP Version 377
• Electronic documentation
• Single license for MP 377 on
USB stick1)
• Standard SD card 256 MB
(empty)
Package MP 377 12" Key
Complete pre-assembled packages
Package MP 277 8" Touch
Order No.
Package MP 377 12" Touch
• MP 377 19" Touch
• WinAC MP Version 377
• Electronic documentation
• Single license for MP 377 on
USB stick1)
• Standard SD card 256 MB
(empty)
• MP 277 10" Key
• WinAC MP Version 277
• Electronic documentation
• Single license for MP 277 on
USB stick1)
• Standard SD card 256 MB
(empty)
B) Subject to export regulations: AL: N and ECCN: EAR99S
F) Subject to export regulations: AL: N and ECCN: 5D002ENC3
1)
Can only be used for license handling
2)
UCL version on request
Siemens ST 80 · 2009
2/139
© Siemens AG 2008
Operator Control and Monitoring Devices
SIMATIC THIN CLIENT
SIMATIC THIN CLIENT
■ Overview
■ Design
SIMATIC THIN CLIENT is installation-compatible with the Multi
Panels MP 277 (10") and MP 377 (12" and 15").
The device has degree of protection IP54 (splash-proof),
enclosure type 12 (indoor use only) and can be expanded with
an options package to degree of protection IP65 (protected
against water jets), enclosure type 4x/type 12 (indoor use only).
2
SIMATIC THIN CLIENT is another member of the SIMATIC Panel
family. Its extremely rugged hardware makes it ideal for industrial
use.
The following versions are available:
• The rack-mounting versions SIMATIC THIN CLIENT 10" Touch
and SIMATIC THIN CLIENT 15" Touch.
• The support arm version SIMATIC THIN CLIENT PRO 15"
Touch
with a rugged and very compact aluminum enclosure which is
completely IP65 protected and therefore suitable for harsh
ambient conditions.
The new THIN CLIENT devices support automatic parameter
definition with DHCP. As an alternative, you can also assign IP
addresses manually. The PROFINET basic services (Lifelist,
Topology view) are supported.
The SIMATIC THIN CLIENT has been available since Q3/2007 as
an especially cost-effective solution.
THIN CLIENT PRO 15" Touch
■ Benefits
The SIMATIC THIN CLIENT is a very economical way of running
a user station on-site on the machine. Typical application
instances are a second station (WinCC flexible with
[email protected]) in connection with another SIMATIC Panel or
Panel PC.
Overcoming greater distances as remote operation terminal is
enabled by using the existing Ethernet network.
The possibility of using SCADA and Office functionality (e.g.
WinCC, SAP, MS-Excel) directly on the machine on-site supports
the vertical integration of the data flow from host systems down
to the machine level (e.g. warehouse utilization).
The SIMATIC THIN CLIENT communicates via SmartAccess or
the Standard RDP (Remote Desktop Protocol) by Microsoft with
a host (SIMATIC Panel, Panel PC or Server) and does not itself
require any installations, licenses or additional software on the
THIN CLIENT.
2/140
In addition, the SIMATIC THIN CLIENT has the following
features:
• Ethernet interface for operating on PROFINET and Ethernet
networks (with Auto-Cross-Over function for one-to-one
connections between server and client via Ethernet cable)
• TFT screen with 64K colors
• Resolution:
- 640 x 480 pixels (10")
- 1024 x 768 pixels (15")
• SIMATIC THIN CLIENT can operate as
- Terminal Client ([email protected] and RDP) and as
- WEB-Client (HTML)
• A mouse and a keyboard can be operated on the USB
interface as external input media. The USB interface supports
the industrial USB Hub 4.
• Printer and storage media are controlled via the host device
Siemens ST 80 · 2009
The THIN CLIENT is also available in a support arm version:
• All-round IP65 protection
• Enclosure type 4x/type 12 (indoor use only)
• For mounting on support arm/pedestal
• 15" touch display
• Rugged die-cast aluminum housing
• Adaptation of the device optionally from above or below
• Direct connection to support arm systems of well-known
manufacturers (e.g. Rittal, Bernstein, Rose, Rolec)
• Supports the globally established VESA 75/VESA 100
standard
© Siemens AG 2008
Operator Control and Monitoring Devices
SIMATIC THIN CLIENT
SIMATIC THIN CLIENT
■ Mode of operation
■ Integration
Operation is possible via Touch or with a keyboard or mouse
connected to a USB port. SIMATIC THIN CLIENT uses a 64K
color display, a USB and an Ethernet interface.
Both devices are compatible with the Multi Panels of corresponding size with regard to mounting cut-out and design.
The RDP connection can be used for operating SCADA systems
such as WinCC as well as office applications such as MS Excel
or SAP direct on the THIN CLIENT at the machine on-site. Unlike
Office viewers under Windows CE, data writing processes are
also possible. RDP is a Microsoft standard protocol that is
supported by all Windows operating systems. This makes it possible to visualize systems from other manufacturers on the
SIMATIC THIN CLIENT and to link them into the system in this
way.
The device is ideal as a second work station for larger systems
because of the low price. [email protected] enables the connection
with a WinCC flexible station. As a remote work station, the
device can be run on machines with extremely high demands on
mechanical robustness (e.g. vibration resistance).
SIMATIC THIN CLIENT can be operated in all systems in a
PROFINET network or in Ethernet networks. As an alternative, a
one-to-one connection with the host is also possible with an
Ethernet cable. In this way, distances of 100 meters (with a
switch even greater distances are possible) can be bridged,
which means a clear cost reduction compared with the standard
remote operator fronts via USB/DVI cable.
■ Function
Commissioning is very simple. SIMATIC THIN CLIENT only
needs an IP address and a host device that it can communicate
with. It does not require any local software installations or configuration. There is thus no need to backup/restore or update the
projects and total costs of ownership are significantly reduced.
■ Technical specifications
SIMATIC THIN CLIENT
10" Touch
15" Touch
PRO 15" Touch
Supply voltage
24 V DC
24 V DC
24 V DC
permissible range
+19.2 V to +28.8 V DC
+19.2 V to +28.8 V DC
+19.2 V to +28.8 V DC
Flash / RAM
Flash / RAM
Flash / RAM
• [email protected]
Yes
Yes
Yes
• RDP
Yes
Yes
Yes
Supply voltage
Memory
Type of storage
Type
Protocols
Protocols (terminal link)
WEB characteristics
LLDP
Yes
Yes
Yes
HTTP
Yes
Yes
Yes
XML
Yes
Yes
Yes
HTML
Yes
Yes
Yes
CSS
Yes
Yes
Yes
Display
Display type
TFT, 65536 Farben
TFT, 65536 Farben
TFT, 65536 Farben
Size
10.4"
15.1"
15.1"
Resolution (W x H in pixel)
640 x 480
1024 x 768
1024 x 768
MTBF backlighting (at 25 °C)
about 50,000 hours
about 50,000 hours
about 50,000 hours
Operating mode
Operating elements
Touch screen
Touch screen
Touch screen
Touchscreen
analog, resistive
analog, resistive
analog, resistive
Connection for mouse/
keyboard/barcode reader
USB / USB
USB / USB
USB / USB
Yes; EN 61000-6-4, interference
emission: Intended for use in
industrial areas.
Yes; EN 61000-6-4, interference
emission: Intended for use in
industrial areas.
Yes; EN 61000-6-4, interference
emission: Intended for use in
industrial areas.
EMC
Emission of radio interferences
to EN 55 011 (limit class A)
Siemens ST 80 · 2009
2/141
2
© Siemens AG 2008
Operator Control and Monitoring Devices
SIMATIC THIN CLIENT
SIMATIC THIN CLIENT
■ Technical specifications
SIMATIC THIN CLIENT
10" Touch
15" Touch
PRO 15" Touch
Front
IP54 when installed, Enclosure
type 12 (indoor use only);
optionally IP65, Enclosure type
4X/Enclosure type 12 (indoor use
only) (6AV6671-6AP00-0AX0)
IP54 when installed, Enclosure
type 12 (indoor use only);
optionally IP65, Enclosure type
4X/Enclosure type 12 (indoor use
only) (6AV6671-6AP00-0AX0)
Complete unit IP65, Enclosure type
4X/type12 (indoor use only)
Rear
IP20
IP20
Complete unit IP65, Enclosure type
4X/type12 (indoor use only)
CE, cULus, C-Tick
CE, cULus, C-Tick
CE, cULus, C-Tick
Max. permissible tilt angle
without external ventilation
+/- 35°
+/- 35°
+/- 45°
Max. relative humidity (in %)
85%; (Storage)
85%; (Storage)
85%; (Storage)
• Operation (vertical installation) 0 °C to +50 °C
Degree of protection
2
Certifications & Standards
Certifications
Ambient conditions
Temperature
0 °C to +50 °C
0 °C to +45 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Interfaces
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
USB
1 x USB
1 x USB
1 x USB
ARM, 266 MHz
ARM, 266 MHz
ARM, 266 MHz
Front of enclosure (W x H)
325 mm x 263 mm
400 mm x 310 mm
400 mm x 310 mm
Mounting cutout/Device depth
(W x H/D) in mm
310 mm x 248 mm / 65 mm device
depth
368 mm x 290 mm / 65 mm device
depth
2.2 kg
3.6 kg
• Transport, storage
Interfaces
Processor
Processor
Dimensions
Weights
• Weight
■ Ordering data
Order No.
SIMATIC THIN CLIENT
Order No.
Option packages:
10" touch device
D
6AV6 646-0AA21-2AX0
15" touch device
D
6AV6 646-0AB21-2AX0
PRO 15" Touch device 1)
D
6AV6 646-2AB21-2AX0
Starter packages:
SIMATIC THIN CLIENT with
[email protected]
IP65 set (upgrade from
IP54 to IP65)
6AV6 671-6AP00-0AX0
Cover foil 10"
6AV6 671-3DC00-0AX0
Cover foil 15"
6AV6 574-1AD00-4EX0
Protective cover 10"
6AV6 671-3CK00-0AX0
Accessories
see HMI accessories,
from page 2/158
(License to operate SmartAccess
on the server)
Touch device 10" with
[email protected] license (panels)
D
6AV6 653-6AA01-2AA0
Touch device 15" with
[email protected] license (panels)
D
6AV6 653-6BA01-2AA0
D) Subject to export regulations: AL: N und ECCN: 5D992B1
2/142
6.5 kg
Siemens ST 80 · 2009
1)
An adapter set is required for mounting. See Chapter 8
"Fully enclosed HMI units".
© Siemens AG 2008
Operator Control and Monitoring Devices
SIMATIC THIN CLIENT
SIMATIC THIN CLIENT
■ Dimensions
All specifications in mm. Tolerance ± 1 mm.
59,9
6,2
400
59,9
6,2
288
113,59
63,21
106,71
310
247
263
113,59
325
30
232,49
232,49
G_ST80_XX_00305
366
SIMATIC THIN CLIENT 10" Touch
G_ST80_XX_00306
30
309
SIMATIC THIN CLIENT 15" Touch
■ More information
400
Support Request:
Additional information is available in the Internet under:
http://www.siemens.com/automation/support-request
Internet:
310
Additional information is available in the Internet under:
http://www.siemens.com/automation/service&support
G_ST80_XX_00350
67,85
90,85
SIMATIC THIN CLIENT PRO 15" Touch
Siemens ST 80 · 2009
2/143
2
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
Introduction
■ Overview
2
SIMATIC Touch Panels (TP), Operator Panels (OP),
Mobile Panels, Multifunctional Platforms (MP)1) and the SIMATIC
HMI software package for PC WinCC flexible Runtime support
HMI functionality in conjunction with:
• SIMATIC S7
• SIMATIC S5
• SIMATIC 505
• SIMOTION
• SINUMERIK2)
• Non-Siemens PLCs:
- Allen Bradley PLC5/-11, 20, 30, 40, 60, 80 (DF1 protocol)
or via KF2 module/DH+ network with PLC5 and SLC500/03,
04, 05
- Allen Bradley SLC500/03, 04, 05 (DF1 protocol) or via KF-3
module/DH485 network with SLC500 and Micro Logix
- Allen Bradley SLC500/00, 01, 02, 03, 04 and MicroLogix
(DH485 protocol)
- Allen Bradley ControlLogix and CompactLogix (Protocol
Ethernet IP)
- GE Fanuc 90-Micro, 90-30, 90-70 (SNP/SNPX protocol)
- LG GLOFA GM with Cnet module (dedicated protocol)
- Mitsubishi FX (FX protocol)
- Mitsubishi FX, Series A, Series Q (MP 4 protocol)
- Modicon 984-120, 130, 131, 141, 145, 380, 381, 385, 480,
485, 680, 685, 780, 785 (MODBUS protocol)
- Modicon TSX Quantum CPU 113, 213, 424, 434, 534 and
TSX Compact (MODBUS protocol)
- Modicon Momentum, TSX Micro (TSX 37), TSX Premium
(TSX 57), TSX Unity Premium, TSX Quantum or TSX Unity
Quantum (Protocol MODBUS TCP/IP)
- Omron SYSMAC C, SYSMAC α, SYSMAC CV (Link/MultiLink
protocol)
- Telemecanique TSX 17, TSX 47/67/87/107 (UNI-TELWAY
protocol)
- Telemecanique TSX 37, TSX 57 (UNI-TELWAY protocol)
For more detailed information, refer to the ProTool or
WinCC flexible User Manuals, the Communication Manual for
Windows-based systems and the ProTool or WinCC flexible
online help.
1)
For the sake of simplicity, SIMATIC TP/OP/MP is always used in the text
below. This is not restrictive, as the information is valid for all systems
referred to above. If there are constraints, direct reference is made to
them in the text.
2)
Required under WinCC flexible: "SINUMERIK HMI copy license WinCC
flexible CE" and "SINUMERIK HMI copy license OA".
For configuring, a "SINUMERIK HMI engineering package WinCC flexible"
is also necessary.
Note:
Interface options for HMI devices: See the individual device
descriptions.
2/144
Siemens ST 80 · 2009
Extended functionality with WinCC flexible
WinCC flexible supports OPC communication for Multi Panel
and WinCC flexible Runtime and HTTP communication for all
panels with integrated Ethernet interface. Both OPC and HTTP
communication can be used in parallel with the process links to
SIMATIC S7/S5/505 or non-Siemens PLCs.
OPC Data Access (MP 277, MP 377 WinCC flexible
Runtime only)
OPC Data Access is an open standard for exchanging both local
and remote variables between various applications via Industrial
Ethernet. The original version of OPC is based on Microsoft
COM/DCOM and, therefore, requires a Microsoft Windowsbased PC operating system (not Windows CE) on both clients
and servers. As OPC XML, communication is based on the
Internet standard SOAP/XML and is, therefore, suitable for
embedded systems with Windows CE.
Options that are required: WinCC flexible/OPC Server.
HTTP communication for the variable exchange between
SIMATIC HMI systems
(only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN,
TP 277, OP 277, Mobile Panel 277, Mobile Panel 277 IWLAN,
MP 277, MP 377, WinCC flexible Runtime)
Communication based on HTTP message frames enables
variables to be exchanged between SIMATIC HMI systems.
Options that are required: WinCC flexible/[email protected] Access.
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
Introduction
■ Overview (continued)
Communication standard
SIMATIC HMI
Version
TP 177B DP/PN
TP 277
OP 177B DP/PN
OP 277
Mobile Panel 177 PN Mobile Panel 277
Mobile Panel 277
IWLAN
MP277
MP 377
WinCC flexible
Runtime
Connection via
2
OPC Data Access V2.0 + V1.1 (COM)/V1.0 (XML)
OPC client
(COM/DCOM)
–
–
–
I
Industrial Ethernet
(see Catalog IK PI)
OPC server
(COM/DCOM)
–
–
–
I1)
Industrial Ethernet
(see Catalog IK PI)
OPC XML client
(SOAP/XML)
–
–
–
I2)
Industrial Ethernet
(see Catalog IK PI)
OPC XML server
(SOAP/XML)
–
–
I3)
–
Industrial Ethernet
(see Catalog IK PI)
HTTP communication for variable exchange between SIMATIC HMI systems
HTTP client
I4)
I4)
I4)
I5)
Industrial Ethernet
(see Catalog IK PI)
HTTP server
I4)
I4)
I4)
I5)
Industrial Ethernet
(see Catalog IK PI)
I System interface possible
– System interface not possible
1)
Option WinCC flexible/OPC Server for WinCC flexible Runtime required
2)
Only with DCOM/XML gateway included in the scope of delivery of WinCC
flexible for access to MP277, MP377 and MP 370 OPC XML servers
3)
Option WinCC flexible/OPC Server for SIMATIC Multi Panel required
4)
Option WinCC flexible/[email protected] for SIMATIC Panel required
5)
Option WinCC flexible/[email protected] for WinCC flexible Runtime required
Siemens ST 80 · 2009
2/145
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
SIMATIC S7
■ Overview
2
The following types of interface are supported in respect of the
link between SIMATIC TP/OP/MP and SIMATIC S7.
• PPI interface:
Link between SIMATIC TP/OP/MP and SIMATIC S7-200 via
PPI. Communication runs on the PPI protocol, a standard
FB as with SIMATIC S5 is not required.
• MPI interface:
Link from SIMATIC TP/OP/MP to SIMATIC S7 via the integrated
PPI interface with S7-200 or MPI interface with S7-300/-400 or
alternatively via the MPI interface of a separate interface module and the bus backplane to the SIMATIC S7-CPU. Communication runs on the MPI protocol (PG/OP communication), a
standard FB as with SIMATIC S5 is not required.
• PROFIBUS interface:
Link from SIMATIC TP/OP/MP to SIMATIC S7 via the integrated
PROFIBUS interface on the CPU or alternatively via the
PROFIBUS interface on a separate interface module and the
bus backplane to the SIMATIC S7-CPU. Communication runs
on the MPI protocol (PG/OP communication), a standard FB
as with SIMATIC S5 is not required.
• PROFINET interface:
Link from SIMATIC TP/OP/MP to SIMATIC S7 via the integrated
PROFINET interface on the CPU or alternatively via the Industrial Ethernet interface on a separate interface module and the
bus backplane to the SIMATIC S7-CPU. Communication runs
on the MPI protocol (PG/OP communication), a standard FB
as with SIMATIC S5 is not required.
The maximum possible number of S7 connections of one CPU is
determined by its power (see Catalog ST 70); from the point of
view of SIMATIC TP/OP/MPs the following restrictions apply:
• OP 73micro, TP 177micro: 1 connection
• OP 73: max. 2 connections
• OP 77A, TP 177A, OP 77B, TP177B, OP 177B, Mobile Panel
177: max. 4 connections
• TP 277, OP 277; Mobile Panel 277, MP 277, MP 377: max. 6
connections
• PC with WinCC flexible Runtime: max. 8 connections
2/146
Siemens ST 80 · 2009
PPI interface (not for OP73micro, TP 177micro, OP 73,
OP 77A, TP 177A, OP 77B, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
From the point of view of the concept, the PPI interface is a pointto-point connection between a SIMATIC TP/OP/MP (PPI master)
or alternatively a PG (PPI master) and an S7-200 (PPI slave).
However, a link between a SIMATIC TP/OP/MP and/or a PG and
an S7-200 (sequential logic point-to-point link, i.e. from the point
of view of the S7-200 only one connection is ever active at any
one time) is also possible (network topology: PPI only).
MPI interface/PROFIBUS interface/Industrial Ethernet
interface
The multipoint-capable communication interfaces of
SIMATIC TP/OP/MP and SIMATIC S7 are used. Options are:
• Interface between one or a number of TP/OP/MPs (MPI
master) and one or a number of S7-300/400s or WinAC
(MPI master).
(possible network topology: MPI/PROFIBUS/Industrial
Ethernet)
• Interface between one or a number of TP/OP/MPs (MPI
master) and one or a number of S7-200s (MPI slave)1)
(possible network topology: PPI/MPI/PROFIBUS)
Unlike PPI connections, MPI connections are static connections
that are set up during booting and then monitored.
The original format of a master/master link has in the meantime
been joined by a master/slave link, which has enabled integration of the S7-200 (except CPU 212). 1)
In principle this type of information exchange between
SIMATIC TP/OP/MP and SIMATIC S7 is independent of the network used, PPI, MPI, PROFIBUS or Industrial Ethernet:
SIMATIC TP/OP/MPs are S7 clients and SIMATIC S7-CPUs are
S7 servers.
1)
Constraints with regard to baud rate for S7-200; see Catalog ST 70.
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
SIMATIC S7
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
TD 100C
TD 200
TD 200C
TD 400C
OP 73 micro
TP 177micro
OP 73
I1)
–
–
Connection via
2
SIMATIC S7 (PPI/MPI)
via PPI on S7-200 (PPI)
2)
MPI cable4)
3)
via MPI or PROFIBUS
(PG/OP communication)
with S7-200
–
I
I
MPI cable4)
via MPI or PROFIBUS
(PG/OP communication)
with S7-300, -400
–
–
I3)
MPI cable4)
via PPI network (PPI)
with max. 1 x S7-200
I1)
–
–
PPI network5)
via PPI network
(PG/OP communication)
with max. 4 x S7-200
I1)
I2)
I3)
PPI network5)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-200
–
I2)
I3)
MPI or PROFIBUS
network5)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-300, -400, WinAC
–
–
I3)
MPI or PROFIBUS
network5)
via Industrial Ethernet (TCP/IP)
(PG/OP communication)
with max. 4 x S7-200, -300, -400,
WinAC
–
–
–
Industrial Ethernet
I System coupling is possible
– System interface not possible
1)
TD series can only be interfaced with max. 1 x S7-200 via PPI (PPI/MPI);
network operation (parallel PG, etc.) possible;
Transfer rate max. 187.5 Kbit/s; cable included in scope of supply
2)
OP 73micro, TP 177 micro can only be interfaced with max. 1 x S7-200
(MPI); network operation (parallel PG, etc.) possible;
Max. transmission rate 187.5 Kbit/s
3)
OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI); network
operation (parallel PG, etc.) possible;
Max. transmission rate 1.5 Mbit/s
4)
MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG
scope of delivery
5)
Bus connector 6GK1 500-0EA02
Siemens ST 80 · 2009
2/147
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
SIMATIC S7
■ Overview (continued)
2
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
TP 177A
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277
IWLAN
MP 177
MP 277
MP 377
WinCC flexible
Runtime
Connection via
–
I1)2)
I1)2)
I1)3)
MPI cable11)
2)5)
2)5)
3)5)
I
MPI cable11)
SIMATIC S7 (PPI/MPI)
via PPI on S7-200 (PPI)
4)
via MPI or PROFIBUS
(PG/OP communication)
on S7-200
I
I
I
via MPI or PROFIBUS
(PG/OP communication)
with S7-300, -400
I4)
I2)
I2)
I3)
MPI cable11)
via PPI network (PPI)
with max. 1 x S7-200
–
I1)2)
I1) 2)
I1)3)
PPI network12)
(see Catalog ST 70
and IK PI)
via PPI network
(PG/OP communication)
with max. 4 x S7-200
I4)
I6)
–
–
PPI network12)
(see Catalog ST 70
and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-200
I4)
I2)5)
I2)5)
I3)5)
MPI or PROFIBUS
network12)
(see Catalogs
ST 70 and IK PI)
I2)
I2)
I3)
MPI or PROFIBUS
network12)
(see Catalogs
ST 70 and IK PI)
I7)8)
I8)9)
I10)
Industrial Ethernet
(see Catalog IK PI)
I4)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-300, -400, WinAC
via Industrial Ethernet (TCP/IP)
(PG/OP communication)
with max. 4 x S7-200, -300, -400,
WinAC
–
I System coupling is possible
– System interface not possible
1)
Can only be interfaced with max. 1 x S7-200 via PPI (PPI); network
operation (parallel PG, etc.) possible
2)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel);
Please refer to the manual for cable assignment
3)
Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2
with a standard PC.
4)
Max. transmission rate 1.5 Mbit/s
5)
Only on passive S7-200; OP 77B (MPI) also on active S7-200
6)
Only OP 77B (MPI)
7)
Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN
8)
Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel);
Please refer to the manual for cable assignment
9)
Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
10)
Connection via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC
11)
MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG
scope of delivery (for download and test purposes only)
12)
Bus connector 6GK1 500-0EA02
2/148
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
SIMATIC S5
■ Overview
A variety of interfaces differing in respect of type and performance are available for linking SIMATIC TP/OP/MP to SIMATIC
S5 (not S5-150U). However, a feature common to all is that from
the point of view of the connected SIMATIC TP/OP/MP, the connection is always a logical point-to-point one, i.e. there is always
a fixed assignment between a SIMATIC TP/OP/MP and a PLC.
AS511 interface (only WinCC flexible Runtime)
S5-90U to -135U, -155U
(except CPU 922 < Version 9,
except CPU 928 [6ES5 928-3UA11],
except CPU 946/947 [6ES5 94n-3UA11],
except CPU 946/947 [6ES5 94n-3UA21],
except CPU 946/947 [6ES5 94n-3UA22] < Version 5)
The AS511 interface runs via the PG interface of SIMATIC S5 and
uses the associated CPU resources, i.e., the performance capability of the SIMATIC TP/OP/MP is determined by the performance capability of the SIMATIC CPU used.
PROFIBUS DP interface (not for OP 77A, TP 177A,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
S5-115U, -135U, -155U via IM 308C or CP 5431 FMS/ DP
(except CPU 922 < Version 9,
except CPU 928 [6ES5 928-3UA11],
except CPU 946/947 [6ES5 94n-3UA11],
except CPU 946/947 [6ES5 94n-3UA21],
except CPU 946/947 [6ES5 94n-3UA22] < Version 5)
The PROFIBUS DP interface supports the connection of:
• One or two SIMATIC TP/OP/MPs as SLAVES via a PROFIBUS
network to a SIMATIC S5-95U with integrated
PROFIBUS DP/master interface [6ES5 095-8ME01]
• Up to 30 SIMATIC TP/OP/MPs as SLAVES via a PROFIBUS
network to a SIMATIC S5 with separate PROFIBUS DP/master
interface IM 308C, or CP 5431 FMS/DP
Communication between SIMATIC TP/OP/MP (DP slave) and
SIMATIC S5 (DP master) runs via PROFIBUS DP message
frames in accordance with EN 50170 with higher-level "HMI
profile". A function block which must be called for each
connected SIMATIC TP/OP/MP is required in the PLC
(FB is included in scope of delivery).
Siemens ST 80 · 2009
2/149
2
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
SIMATIC S5
■ Overview (continued)
2
Controller
SIMATIC HMI
Target hardware
(PROTOCOL)
(physics)
OP 77A
TP 177A
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
WinCC flexible
Runtime
OP 277
Mobile Panel 277
Mobile Panel 277 IWLAN
MP 177
MP 277
MP 377
–
–
–
Connection via
SIMATIC S5 (AS511)
S5-90U to 155U
except CPU 922
< version 9,
except CPU 928
(6ES5 928-3UA11)
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22
< version 5) (TTY)
I
6ES5 734-1BD201)
(3.2 m)
6XV1 440-2A…
(see HMI accessories/connecting
cables)
SIMATIC S5 (PROFIBUS DP + HMI)
via PROFIBUS DP with 1 x
S5-95U/L2-DP/master
[6ES5 095-8ME02]
–
I2)
I2)
I3)
PROFIBUS4)
(see Catalog
ST 50/IK PI)
via PROFIBUS DP with
IM 308C on S5-115U,
-135U, -155U
except CPU 922
< version 9,
except CPU 928
(6ES5 928-3UA11),
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22
< version 5)
–
I2)
I2)
I3)
PROFIBUS4)
(see Catalog
ST 50/IK PI)
via PROFIBUS DP with
CP 5431 FMS/DP on
S5-115U, -135U, -155U
except CPU 922
< version 9,
except CPU 928
(6ES5 928-3UA11),
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22
< version 5)
–
I2)
I2)
I3)
PROFIBUS4)
(see Catalog
ST 50/IK PI)
I System interface possible
– System interface not possible
1)
PC cable with integrated level converter RS 232/TTY
2)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable assignment.
3)
Connection via integrated MPI/PROFIBUS interface, use the CP 5611 A2
with a standard PC
4)
Bus connector 6GK1 500-0EA02
2/150
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
SIMATIC 505
■ Overview
A variety of interfaces differing in respect of type and performance are available for linking SIMATIC TP/OP/MP to
SIMATIC 505. However, a feature common to all is that from the
point of view of the connected SIMATIC TP/OP/MP, the connection is always a logical point-to-point one, i.e., there is always a
fixed assignment between a TP/OP/MP and a PLC.
PROFIBUS DP interface (not for OP 77A, TP 177A,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
SIMATIC 505 PLC or SIMATIC 545, SIMATIC 555 with CP 5434
With the PROFIBUS DP interface, up to 30 SIMATIC TP/OP/MPs
can be connected as SLAVES to one SIMATIC 545, 555 via a
PROFIBUS network, with plug-in PROFIBUS DP/master interface
type CP 5434.
NITP interface (not for OP 77A, TP 177A,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP (DP/slave) and SIMATIC 505 (DP/master) is implemented by means of
PROFIBUS DP message frames in accordance with EN 50170
with higher-level "HMI profile". An application ladder which must
be called for each connected SIMATIC TP/OP/MP is required in
the PLC (example of application ladder included in ProTool
scope of delivery).
The NITP connection runs via the PG interface of SIMATIC 505
and uses the associated CPU resources, i.e. the performance
capability of the SIMATIC TP/OP/MP is determined by the performance capability of the SIMATIC CPU used.
Controller
SIMATIC HMI
Target hardware
(PROTOCOL)
(physics)
OP 77A
TP 177A
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277 IWLAN
MP 277
MP 377
WinCC flexible
Runtime
Connection via
–
I1)2)
I1)2)
I
PPX: 2601 094-80013)
SIMATIC 505 (NITP)
PLC 525, 535, 565T
(RS 232)
See online help6)
PLC 545, 555
(RS 232)
–
I1)2)
I1)2)
I
PPX: 2601 094-80013)
6xv1 440-2K…
(see HMI
accessories/
connecting cables)
PLC 535, 545/CPU 1101,
565T (RS 422)
–
I1)
I1)
I4)
See online help6)
PLC 545/CPU 1102, 555
(RS 422)
–
I1)
I1)
I4)
See online help6)
I1)
I1)
I5)
PROFIBUS7)
(see Catalog
ST 50/IK PI)
SIMATIC 505 (PROFIBUS DP + HMI)
via PROFIBUS DP to
1 x PLC 545, 555 with
CP 5434
–
I System interface possible
– System interface not possible
1)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable assignment.
2)
For Touch Panel, Operator Panel, Multi Panel, the RS 422/RS 232 adapter
6AV6 671-8XJ00-0AX0 is required
3)
A standard adapter (9-/25-pin male) is required on the PLC
4)
A commercially available level converter (RS 232/RS 422) is required on
the PC
5)
Connection via integrated MPI/PROFIBUS interface, use the CP 5611 A2
with a standard PC
6)
Detailed information (cable assignment) can be found in the online help
for WinCC flexible and in the Communication User Manual for Windowsbased systems
7)
Bus connector 6GK1 500-0EA02
Siemens ST 80 · 2009
2/151
2
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
PLCs from other manufacturers
■ Overview
Allen Bradley
2
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Allen Bradley:
DF1 interface (not for OP 77A, TP 177A, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs on the basis of the DF1 protocol; the following have
been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and the PG
interface on an Allen Bradley PLC5 or the DF1 interface on an
Allen Bradley SLC500 (point-to-point link)
• The integration of SIMATIC TP/OP/MP via Allen Bradley KF2
gateway in an Allen Bradley DH+ network. Communication is
possible between SIMATIC TP/OP/MP and up to 4 SLC 500
PLCs or PLC5s (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with
TP 170A)
• The integration of SIMATIC TP/OP/MP via Allen Bradley KF3
gateway in an Allen Bradley DH485 network. Communication
is possible between SIMATIC TP/OP/MP and up to 4 PLCs
type SLC 500 or MicroLogix (multipoint link from the point of
view of the SIMATIC TP/OP/MP; only one connection possible
with TP 170A)
DH485 interface (not for OP 77A, TP 177A,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs on the basis of the DH485 protocol; the following
have been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and an Allen
Bradley SLC500 or MicroLogix (point-to-point link)
• The integration of SIMATIC TP/OP/MP via Allen Bradley AIC
adapter in an Allen Bradley DH485 network. Communication
is possible between SIMATIC TP/OP/MP and up to 4 PLCs
type SLC 500 or MicroLogix (multipoint link from the point of
view of the SIMATIC TP/OP/MP; only one connection possible
with TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with WinCC
flexible Runtime) in an Allen Bradley DH485 network. Communication is possible between SIMATIC TP/OP/MP and up to
4 PLCs type SLC 500 or MicroLogix (multipoint link from the
point of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A)
Ethernet IP protocol (not for OP 77A, TP 177A, OP 77B,
TP 177B DP, OP 177B DP, Mobile Panel 177 DP,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs based on the Ethernet IP protocol; SIMATIC
TP/OP/MP integration is tested and released in an Ethernet IP
network. Communication is possible between SIMATIC
TP/OP/MP and up to 4 ControlLogix or CompactLogix PLCs
(multipoint link from the point of view of the SIMATIC TP/OP/MP)
2/152
Siemens ST 80 · 2009
GE-Fanuc (not for OP 77A, TP 177A, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and GE-Fanuc
runs on the basis of the SNP protocol; the following have been
tested and released:
• Direct connection between a SIMATIC TP/OP/MP and a GEF
90-Micro, 90-30 or 90-70 (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network via
adapter. Communication is possible between SIMATIC
TP/OP/MP and up to 4 GEF 90-Micro, 90-30 or 90-70 PLCs
(multipoint link from the point of view of the SIMATIC
TP/OP/MP; only one connection possible with TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/Pro
Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 GEF 90-Micro, 90-30 or 90-70 PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A)
LG GLOFA GM (not with OP 77A, TP 177A,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and LG GLOFA
GM runs on the basis of the dedicated protocol; the following
have been tested and released:
• Connection between a SIMATIC TP/OP/MP and an
LG GLOFA GM with Cnet module (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network via LG
Cnet module. Communication is possible between SIMATIC
TP/OP/MP (not PC with ProTool/Pro Runtime) and up to 4
LG GLOFA GM PLCs on the network (multipoint link from the
point of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A)
Mitsubishi (not for OP 77A, TP 177A, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Mitsubishi:
FX protocol
This communication between SIMATIC TP/OP/MP and
Mitsubishi runs on the basis of the FX protocol; the direct connection between a SIMATIC TP/OP/MP and the PG interface of a
Mitsubishi FX/FX0 (logical point-to-point link) has been tested
and released.
MP4 protocol
This communication between SIMATIC TP/OP/MP and
Mitsubishi runs on the basis of the MP4 protocol; the following
have been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and a
Mitsubishi Series FX, Series A or Series Q (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network via
Mitsubishi converter FX-48SC-IF. Communication is possible
between SIMATIC TP/OP/MP and up to 4 Series FX, Series A
or Series Q PLCs (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with TP
170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/Pro
Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 Series FX, Series A or Series Q PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A)
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
PLCs from other manufacturers
■ Overview (continued)
Modicon
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Modicon:
MODBUS protocol (not with OP 77A, TP 177A,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and Modicon runs
on the basis of the MODBUS protocol; the following have been
tested and released:
• Direct connection between a SIMATIC TP/OP/MP and the
MODBUS interface on a Modicon 984, TSX Quantum or TSX
Compact (point-to-point link)
• The integration of a SIMATIC TP/OP/MP via Modicon
MODBUS PLUS bridge BM85-000/the bridge function on a
MODICON 984-145/TSX Quantum in a MODBUS PLUS
network and communication between SIMATIC TP/OP/MP
(MODBUS/master) and up to 4 Modicon 984 or TSX Quantum
PLCs (MODBUS/slave) on the network (multipoint link from the
point of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A).
MODBUS TCP/IP protocol (not for OP 77A, TP 177A,
OP77B, TP 177B DP, OP 177B DP, Mobile Panel 177 DP,
Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and Modicon runs
on the basis of the MODBUS TCP/IP protocol; the following have
been tested and released:
• Integration of SIMATIC TP/OP/MP in a MODBUS TCP/IP
network. Communication is possible between SIMATIC
TP/OP/MP and up to 4 Momentum, TSX Micro ( TSX 37 ), TSX
Premium ( TSX 57 ), TSX Unity Premium, TSX Quantum or TSX
Unity Quantum PLCs (multipoint link from the point of view of
the SIMATIC TP/OP/MP)
• The communication between SIMATIC TP/OP/MP via TCP/IP
Modbus Plus Bridge 174 CEV 200 40 / MODBUS PLUS
network and Modicon 984 (except 984A, 984B, 984X ), TSX
Compact, TSX Quantum or TSX Unity Quantum (multipoint link
from the point of view of the SIMATIC TP/OP/MP)
Omron (not for OP 77A, TP 177A, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and Omron runs
on the basis of the Link/MultiLink protocol; the following have
been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and an
Omron Sysmac C, Sysmac α or Sysmac CV (point-to-point
link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network via
Omron converter NT-AL001. Communication is possible between SIMATIC TP/OP/MP and up to 4 Sysmac C, Sysmac α
or Sysmac CV PLCs (multipoint link from the point of view of
the SIMATIC TP/OP/MP; only one connection possible with
TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/Pro
Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 Sysmac C, Sysmac α or Sysmac CV PLCs (multipoint
link from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Telemecanique1) (not for OP 77A, TP 177A,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Data exchange between SIMATIC TP/OP/MP and
Telemecanique runs on the basis of the UNI-TELWAY protocol;
the following have been tested and released:
• Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via
Telemecanique outlet TSX SCA62 and a Telemecanique
TSX 17 or TSX 47/67/87/107 (UNI-T/master) (logical point-topoint link)
• Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via
Telemecanique outlets TSX SCA62 + ACC01 and a Telemecanique TSX 37 or TSX 57 (UNI-T/master) (logical point-to-point
link)
• The integration of a SIMATIC TP/OP/MP via Telemecanique
outlet TSX SCA62 in a UNI-TELWAY network and communication between SIMATIC TP/OP/MP (UNI-T/slave) and up to 4
TSX 17, TSX 37, TSX 57 or TSX 47/67/87/107 PLCs (UNI-T/
master or slave) on the network (multipoint link from the point
of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A).
1)
Not for WinCC flexible Runtime
Siemens ST 80 · 2009
2/153
2
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
PLCs from other manufacturers
■ Overview (continued)
2
Controller
SIMATIC HMI
Target hardware
(PROTOCOL)
(physics)
OP 77A
TP 177A
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277 IWLAN
MP 277
MP 377
WinCC flexible
Runtime
Connection via
SLC 500/03, 04, 05 or
MicroLogix (RS 232)
–
I1)2)
I1)2)
I
1747 CP37)
See online help9)
PLC 5/11, 20, 30, 40, 60, 80
(RS 232)
–
I1)2)
I1)2)
I
1784 CP107)
See online help9)
PLC 5/11, 20, 30, 40, 60, 80
(RS 422)
–
I1)
I1)
–
See online help9)
via KF2 gateway and
–
DH+ network with up to
4 x SLC 500/00, 01, 02, 03, 04
or PLC 5/11, 20, 30, 40, 60, 80
(RS 232)
I1)2)
I1)2)
I
1784 CP107)8)
See online help9)
via KF3 gateway and
DH485 network with up to
4 x SLC 500 or MicroLogix
(RS 232)
–
I1)2)
I1)2)
I
1784 CP107)8)
See online help9)
SLC 500/03, 04, 05 or
MicroLogix (RS 232)
–
I1)2)
I1)2)
I
See online help9)
via AIC adapter and
DH485 network with up to
4 x SLC 500 or MicroLogix
(RS 232)
–
I1)2)
I1)2)
I
See online help9)
via DH485 network
with up to 4 x SLC 500 or
MicroLogix (RS 485)
–
I1)
I1)
–
See online help9)
I3)4)
I4)5)
I6)
See online help9)
Allen Bradley (DF1)
Allen Bradley (DH485)
Allen Bradley (Ethernet IP)
–
via Ethernet IP network
with up to 4 x ControlLogix or
CompactLogix
I System interface possible
– System interface not possible
1)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable assignment.
2)
For Touch Panel, Operator Panel, Multi Panel, the RS 422/RS 232 adapter
6GK1 901-1BB10-2AA0 is required
3)
Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN
4)
Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable
assignment.
5)
Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
6)
Connection via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC
7)
Allen Bradley PC cable
8)
Cable for connection to KF2/KF3 gateway; a gander changer (25-pin
socket/25-pin socket) is required on the gateway side
9)
Detailed information (cables used) can be found in the online help for
WinCC flexible and in the Communication User Manual for Windowsbased systems
2/154
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
PLCs from other manufacturers
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware
(PROTOCOL)
(physics)
OP 77A
TP 177A
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
WinCC flexible
OP 277
Runtime
Mobile Panel 277
Mobile Panel 277 IWLAN
MP 277
MP 377
Connection via
GEF 90-Micro, 90-30, 90-70
(RS 232)
–
I1)2)
I1)2)
I
See online help4)
via adapter with up to
4 x GEF 90-Micro, 90-30,
90-70 (RS 232)
–
I1)2)
I1)2)
I
See online help4)
via adapter with up to
4 x GEF 90-Micro, 90-30,
90-70 (RS 422)
–
I1)
I1)
–
See online help4)
GLOFA-GM with
Cnet module (RS 232)
–
I1)2)
I1)2)
I
See online help4)
With up to 4 x GLOFA-GM
with Cnet module (RS 422)
–
I1)
I1)
–
See online help4)
–
–
–
I
SC-0715)
–
6XV1 440-2P…
(max. 20 m)
I
SC-0815)
I
6XV1 440-2P…
(max. 20 m)
2
GE-Fanuc (SNP)
LG GLOFA (Dedicated)
Mitsubishi FX (Ethernet IP)
FX0 (RS 422)
I
FX (RS 422)
–
1)
–
I
I
1)
–
1)
I
1)
Mitsubishi (MP4)
• Series FX with
communications module
–
I1)2)
I1)2) )
I
See online help4)
–
I1)2)
I1)2)
I
See online help4)
–
I1)
I1)
–
See online help4)
• Series A (AnN, AnA, AnU,
AnS) with interface module
• Series Q (QnA, QnAS) with
interface module (RS 232)
via FX-48SC-IF converter
with up to 4 PLCs
• Series FX with
communications module
• Series A (AnN, AnA, AnU,
AnS) with interface module
• Series Q (QnA, QnAS) with
interface module (RS 232)
with up to 4 PLCs
• Series FX with communications module
• Series A (AnN, AnA, AnU,
AnS) with interface module
• Series Q (QnA, QnAS) with
interface module (RS 422)
I System interface possible
– System interface not possible
1)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable assignment.
2)
For Touch Panel, Operator Panel, Multi Panel, the RS 422/RS 232 adapter
6GK1 901-1BB10-2AA0 is required
3)
With connection using a Mitsubishi PC cable, an 15-pin/9-pin adapter
6XV1 440-2UE32 is required
4)
Detailed information (cables used) can be found in the online help for
WinCC flexible and in the Communication User Manual for Windowsbased systems
5)
Mitsubishi PC cable with integrated level converter RS 232/RS422
Siemens ST 80 · 2009
2/155
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
PLCs from other manufacturers
■ Overview (continued)
Controller
2
SIMATIC HMI
Target hardware (PROTOCOL) OP 77A
(physics)
TP 177A
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
WinCC flexible
OP 277
Runtime
Mobile Panel 277
Mobile Panel 277 IWLAN
MP 277
MP 377
Connection via
–
I1)2)
I1)2)
I
See online help7)
via bridge BM85-000 or
–
PLC with bridge functionality/
MODBUS PLUS – Network
up to 4 x 984-120, ... or
TSX Quantum – CPU 113, ... (RS
232)
I1)2)
I1)2)
I
See online help7)
TSX Compact (RS 232)
–
I1)2)
I1)2)
I
See online help7)
–
I3)4)
I4) 5)
I6)
See online help7)
via TCP/IP-Modbus Plus
–
Bridge174 CEV 200 40 /
MODBUS PLUS – network
to max. 4 x
TSX Unity Quantum or
TSX Quantum or
TSX Compact or
984-120, ... (except 984A, 984B,
984X)
I3)4)
I4)5)
I6)
See online help7)
Modicon (MODBUS)
984-120, 130, 131, 141, 145,
380, 381, 185, 480, 485, 680,
685, 780, 785, or TSX-Quantum-CPU 113, 213, 424, 434,
534 (RS 232)
Modicon (MODBUS TCP/IP)
Via MODBUS TCP/IP –
network
to max. 4 x
TSX Unity Quantum or
TSX Unity Premium or
TSX Quantum or TSX
Quantum with TCP/IP
module 140 NOE 771 01 or
TSX Unity Premium or
TSX Premium with TCP/IP
module TSX ETY 110 or
TSX Micro with TCP/IP
module TSX ETY 410 or
Momentum with CPU adapter
171 CCC 980 30
I System interface possible
– System interface not possible
1)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable assignment.
2)
For Touch Panel, Operator Panel, Multi Panel, the RS 422/RS 232 adapter
6GK1 901-1BB10-2AA0 is required
3)
Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN
4)
Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable
assignment.
5)
Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
6)
Connection via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC
7)
Detailed information (cables used) can be found in the online help for
WinCC flexible and in the Communication User Manual for Windowsbased systems
2/156
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
System interfaces: Panels and runtime software
PLCs from other manufacturers
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
TP 177A
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277
IWLAN
MP 277
MP 377
WinCC flexible
Runtime
Connection via
• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC a
• SYSMAC CV
(RS 232)
–
I1)2)
I1)2)
I
See online help3)
via NT-AL001 converter with up to
4 PLCs
• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC a
• SYSMAC CV
(RS 232)
–
I1)2)
I1)2)
I
See online help3)
with up to 4 PLCs
• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC a
• SYSMAC CV
(RS 422)
–
I1)
I1)
–
See online help3)
via TSX SCA62 outlet with TSX 17
or TSX 47/67/87/107 (RS 485)
–
I1)
I1)
–
See online help3)
via TSX SCA62 + ACC01
outlets with TSX 37/57 (RS 485)
–
I1)
I1)
–
See online help3)
via TSX SCA62 outlet and
UNI-TELWAY networkwith 4 x TSX
17 or TSX 37/57 or
TSX 47/67/87/107 (RS 485)
–
I1)
I1)
–
See online help3)
2
Omron (Link/MultiLink)
Telemecanique (UNI-TELWAY)
I System interface possible
– System interface not possible
1)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
2)
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable assignment.
3)
For Touch Panel, Operator Panel, Multi Panel, the RS 422/RS 232 adapter
6GK1 901-1BB10-2AA0 is required
4)
Detailed information (cables used) can be found in the online help for
WinCC flexible and in the Communication User Manual for Windowsbased systems
Siemens ST 80 · 2009
2/157
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Industrial USB Hub 4
■ Overview
2
HMI accessories include:
• Industrial USB Hub 4
• Connecting cables
• Connectors
• Accessories for SIMATIC Mobile Panels
• Memory cards
• Converters/adapters
• Service packs
• Protective covers
• Cover foils
• Mounting frames
• Back-up battery and accumulator
Industrial USB Hub 4
• The Industrial USB Hub 4 is used as a USB hub for the
connection of peripheral devices to Multi Panels, Panel PCs
and standard PCs.
• The industrial USB Hub 4 with IP65 degree of protection on
the front (Service Kit required) can be mounted in a control
cabinet. This simplifies the use of USB peripherals in harsh
industrial environments.
• USB peripherals can be connected to the panel and operated
via the Industrial USB Hub 4 without opening the cabinet door.
The ports are also accessible from the rear even in the control
cabinet.
Attention:
For detailed information please refer to Chapter 3, "Extension
components".
2/158
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Connecting cables
■ Overview
Key
lara
P = PROCESS COUPLING
p = optional process coupling
D = DOWNLOAD (update operating system, project, …)
U = Booting (in the case of a missing or damaged
operating system)
MBP = Mobile Panel
Example – connecting cables
S5-TTY
(PG-S5)
S5-TTY
(TD/OPS5)
S7 PG702
RS232
external
TD-PPI (incl. RS232
voltage)
zero
modem
RS232/PPI
multi-master
cable
USB/PPI multi- MPI (PG-S7)
master cable to 187.5
kbaud
6ES5 734- 6XV1 440- 6ES7 7056XV1 440- 6ES7 9016ES7 901- 6ES7 9012xxxx
2Axxx
0AA00-7BA0 2Kxxx
3EB10-0XA0 1BF003CB30-0XA0
0XA0
6ES7 9013DB30-0XA0
6ES7 9010BF00-0AA0
PP7
-
-
-
-
-
-
-
-
-
PP17 I
-
-
-
-
-
-
-
-
-
PP17-II
-
-
-
-
-
-
-
-
-
TD100C
-
-
-
-
P
-
D/U
-
-
TD200
-
-
-
-
P
-
D/U
-
P
TD200C
-
-
-
-
P
-
D/U
-
P
TD17
D
P
-
P
-
D/U
-
-
P
TP070
-
-
-
-
-
-
D/U
-
-
TP170micro
-
-
-
-
-
-
D/U
-
-
TP170A
-
P
-
-
-
D/U
-
-
P
TP177micro
-
-
-
-
-
-
D/U
D/U
-
TP177A
-
P
-
P
-
-
D/U
D/U
P
TP170B mono
-
P
-
P
-
D/U
-
-
P/D
TP170B color
-
P
-
P
-
D/U
-
-
P/D
TP177B DP
-
-
-
P3)
-
-
D/U
-
P/D
TP177B PN/DP
-
-
-
P3)
-
-
D/U
-
P/D
TP270-6
-
P
-
P
-
D/U
-
-
P/D
TP277-6
-
-
-
P3)
-
-
D/U
-
P/D
MP177-6 T
-
-
-
P3)
-
-
D/U
-
P/D
MP270-6 T
-
P
-
P
-
D/U
-
-
P/D
MP277-8 T
-
-
-
P3)
-
-
D/U
-
P/D
TP270-10
-
P
-
P
-
D/U
-
-
P/D
MP277-10 T
-
-
-
P3)
-
-
D/U
-
P/D
MP370-12 T
-
P
-
P3)
-
D/U
-
-
P/D
MP370-15 T
-
P
-
P3)
-
D/U
-
-
P/D
MP377-12 T
-
-
-
P3)
-
-
D/U
-
P/D
MP377-15 T
-
-
-
P3)
-
-
D/U
-
P/D
-
P3)
-
-
D/U
-
P/D
MP377-19 T
-
-
Siemens ST 80 · 2009
2/159
2
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Connecting cables
■ Overview (continued)
2
S5-TTY
(PG-S5)
S5-TTY
(TD/OPS5)
S7 PG702
RS232
external
TD-PPI (incl. RS232
voltage)
zero
modem
RS232/PPI
multi-master
cable
USB/PPI multi- MPI (PG-S7)
master cable to 187.5
kbaud
OP3
-
-
P
-
P1)
-
-
-
-
OP73micro
-
-
-
-
P
-
D/U
D/U
P
OP73
-
-
-
-
P
-
D/U
D/U
P/D
OP7 PP
D
P
-
P
-
-
-
-
-
OP7 DP
-
-
-
-
-
-
-
-
P
OP7 DP12
D
P
-
P
-
-
-
-
P
OP77A
-
-
-
-
-
-
D/U
D/U
P/D
-
-
P
-
D/U
-
-
P/D
OP77B
OP17 PP
D
P
-
P
-
-
-
-
-
OP17 DP
-
-
-
-
-
-
-
-
P
OP17 DP12
D
P
-
P
-
-
-
-
P
OP170B
-
-
-
-
-
D/U
-
-
P/D
OP177B DP
-
-
-
P3)
-
-
D/U
-
P/D
OP177B PN/DP
-
-
-
P3)
-
-
D/U
-
P/D
OP270-6
P
-
-
P
-
D/U
-
-
P/D
OP277-6
-
-
-
P3)
-
-
D/U
-
P/D
MP277-8 K
-
-
-
P3)
-
-
D/U
-
P/D
OP270-10
P
-
-
P
-
D/U
-
-
P/D
MP270-10 K
P
-
-
P
-
D/U
-
-
P/D
MP277-10 K
-
-
-
P3)
-
-
D/U
-
P/D
MP370-12 K
P
-
-
P3)
-
D/U
-
-
P/D
MP377-12 K
-
-
-
P3)
-
-
D/U
-
P/D
MBP 170
-
-
-
-
-
-
-
-
-
MBP 177 DP
-
-
-
-
-
-
D/U
-
-
MBP 177 PN
-
-
-
-
-
-
D/U
-
-
MBP 277
-
-
-
-
-
-
D/U
-
-
DP PtP
DP Standard
DP (Mobile
Panel)
PN PtP
Cross
PN Ethernet PN
(Mobile
Panel)
Conv. 422-232 Conv. 232-TTY 90° angular
(15-contact
1:1)
6XV1 830- Standard
6XV1 4400Axxx
PROFIBUS 4Axxx
(2-contact)
6XV1 870- Standard
3RH20 2) Ethernet
CAT5
6XV1 440- 6AV6 6714Bxxx
8XE00-0AX0
6ES5 7341BD20
6AV6 6718XD00-0AX0
PP7
P
P
-
-
-
-
-
-
-
PP17 I
P
P
-
-
-
-
-
-
-
PP17-II
P
P
-
-
-
-
-
-
-
TD100C
-
-
-
-
-
-
-
-
-
TD200
-
-
-
-
-
-
-
-
-
TD200C
-
-
-
-
-
-
-
-
-
TD17
P
P
-
-
-
-
-
-
p/D/U
TP070
P
P
-
-
-
-
-
-
p/D/U
TP170micro
P
-
-
-
-
-
-
-
p/D/U
TP170A
P
P
-
-
-
-
-
P
p/D/U
TP177micro
P
-
-
-
-
-
-
-
p/D/U
TP177A
P
P
-
-
-
-
-
-
p/D/U
TP170B mono
P/D
P/D
-
-
-
-
-
P
p/D/U
TP170B color
P/D
P/D
-
-
-
-
-
P
p/D/U
TP177B DP
P/D
P/D
-
-
-
-
P
-
p/D/U
TP177B PN/DP
P/D
P/D
-
P/D
P/D
-
P
-
p/D/U
2/160
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Connecting cables
■ Overview (continued)
DP PtP
DP Standard
DP (Mobile
Panel)
PN PtP
Cross
PN Ethernet PN
(Mobile
Panel)
Conv. 422-232 Conv. 232-TTY 90° angular
(15-contact
1:1)
6XV1 830- Standard 6XV1 4400Axxx
PROFIBUS 4Axxx
(2-contact)
6XV1 8703RH20 2)
Standard
Ethernet
CAT5
6XV1 4404Bxxx
6AV6 6718XE00-0AX0
6ES5 7341BD20
6AV6 6718XD00-0AX0
TP270-6
P/D
P/D
-
p/D
P/D
-
-
P
p/D/U
TP277-6
P/D
P/D
-
P/D
P/D
-
P
-
p/D/U
MP177-6 T
P/D
P/D
-
P/D
P/D
-
P
-
p/D/U
MP270-6 T
P/D
P/D
-
P/D
P/D
-
-
P
p/D/U
MP277-8 T
P/D
P/D
-
P/D
P/D
-
P
-
p/D/U
TP270-10
P/D
P/D
-
p/D
P/D
-
-
P
p/D/U
MP277-10 T
P/D
P/D
-
P/D
P/D
-
P
-
p/D/U
MP370-12 T
P/D
P/D
-
P/D
P/D
-
-
P
p/D/U
MP370-15 T
P/D
P/D
-
P/D
P/D
-
-
P
p/D/U
MP377-12 T
P/D
P/D
-
P/D
P/D
-
P
-
P/ D/U
MP377-15 T
P/D
P/D
-
P/D
P/D
-
P
-
P/ D/U
MP377-19 T
P/D
P/D
-
P/D
P/D
-
P
-
P/ D/U
OP3
P
-
-
-
-
-
-
-
-
OP73micro
P
-
-
-
-
-
-
-
-
OP73
P
P
-
-
-
-
-
-
-
OP7 PP
-
-
-
-
-
-
-
-
p/D/U
OP7 DP
P
P
-
-
-
-
-
-
p/D/U
OP7 DP12
P
P
-
-
-
-
-
-
p/D/U
OP77A
P
P
-
-
-
-
-
-
p/D/U
OP77B
P
P
-
-
-
-
-
P
p/D/U
OP17 PP
-
-
-
-
-
-
-
-
p/D/U
OP17 DP
P
P
-
-
-
-
-
-
p/D/U
OP17 DP12
P
P
-
-
-
-
-
-
p/D/U
OP170B
P
P
-
-
-
-
-
p
p/D/U
OP177B DP
P
P
-
-
-
-
P
-
p/D/U
OP177B PN/DP
P
P
-
P/D
P/D
-
P
-
p/D/U
OP270-6
P
p
-
p/D
P/D
-
-
P
p/D/U
OP277-6
P
P
-
P/D
P/D
-
P
-
p/D/U
MP277-8 K
P
P
-
P/D
P/D
-
P
-
p/D/U
OP270-10
P
p
-
p/D
P/D
-
-
P
p/D/U
MP270-10 K
P
P
-
P/D
P/D
-
-
P
p/D/U
MP277-10 K
P
P
-
P/D
P/D
-
P
-
p/D/U
MP370-12 K
P
P
-
P/D
P/D
-
-
P
p/D/U
MP377-12 K
P/D
P/D
-
P/D
P/D
-
P
-
P/ D/U
MBP 170
-
-
P/D
-
-
-
-
P
-
MBP 177 DP
P/D
-
P/D
-
-
-
-
-
-
MBP 177 PN
-
-
-
-
-
P/D
-
-
-
MBP 277
-
-
P/D
-
-
P/D
-
-
-
1)
With gender changer
2)
Not possible with PN/IO, only with HUB/Switch
3)
Only in conjunction with the RS422/232 converter
Siemens ST 80 · 2009
2/161
2
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Connecting cables
■ Ordering data
2
Order No.
Order No.
Connecting cables 6ES5 731-1….
Connecting cables 6ES7 901-1....
for SIMATIC S5
(S5-90U to S5-155U),
PG6xx (TTY, 20 mA)
RS 232 cable
Standard lengths
Connecting cables 6ES7 901-3....
• 5.0 m
• 10.0 m
• 5.0 m
6ES5 731-1BF00
Process connecting cable
6ES5 731-1CB00
For connecting TD 100C
or TD 200C to S7-200
Custom lengths
• Max. 200.0 m
6ES5 731-1...0
Connecting cables 6ES5 731-6….
for SIMATIC S5,
interface adapter for PC 16-20b
required for the connection
between programming device
and connecting cable
6ES5 731-6AG00
6ES7 901-1BF00-0XA0
6ES7 901-3EB10-0XA0
Connecting cables 6XV1 440-2A...
Connecting cable between
TD/TP/OP and PLC S5-90U to 155U
Standard lengths
• 3.2 m
6XV1 440-2AH32
• 5.0 m
6XV1 440-2AH50
Connecting cables 6ES5 734-1....
• 10.0 m
6XV1 440-2AN10
for SIMATIC S5,
connecting cable between PLC
15-pin and PC 25-pin
• 20.0 m
6XV1 440-2AN20
• 32.0 m
6XV1 440-2AN32
Standard lengths
• 50.0 m
6XV1 440-2AN50
• 3.2 m
6ES5 734-1BD20
Custom lengths
Connecting cables 6ES5 734-2....
Max. 1000.0 m
for SIMATIC S5,
connecting cable between PG 7
and S5-90U to S5-155U
Connecting cables 6XV1 440-2K...
Standard lengths
• 10.0 m
6ES5 734-2CB00
Custom lengths
• max. 1000.0 m
6ES5 734-2...0
6XV1 440-2A...
Connecting cable between
TD/TP/OP and
SIMATIC 505 PLC 545, 555;
ALLEN BRADLEY SLC500 03,04
via RS232/15-pin socket and PC
via RS232/9-pin male
Standard lengths
Connecting cables 6ES7 705-...
• 3.2 m
6XV1 440-2KH32
for SIMATIC S7
Connecting cable between
PG 702 and SIMATIC S7 via
PPI/MPI
• 5.0 m
6XV1 440-2KH50
• 10.0 m
6XV1 440-2KN10
Adapter cable 6XV1 440-2U...
Standard length
• 2.5 m 1)
6ES7 705-0AA00-7BA0
between TD/OP (RS 232/15-pin
socket) and non-Siemens PC
cable (RS 232/9-pin socket)
Non-heating apparatus cables 6ES7 900-1....
• 0.3 m
for SIMATIC Box PC and
Panel PC
PROFIBUS connecting cable
830-1C
SIMATIC PC power cable,
230 V AC, angled, 3 m, for:
For connection of data terminal,
precut/preassembled with two
Sub-D connectors, 9-pin, terminated at both ends
for PP, OP 73micro, TP 070,
OP73, TP 170micro, TP 177micro,
OP 77A/B, TP 170A, TP 177A,
TP/OP 170B, TP/OP 177B,
MP 270B
• Germany
6ES7 900-1AA00-0XA0
• United Kingdom
6ES7 900-1BA00-0XA0
• Switzerland
6ES7 900-1CA00-0XA0
• USA
6ES7 900-1DA00-0XA0
• Italy
6ES7 900-1EA00-0XA0
6XV1 440-2UE32
Connecting cables 6ES7 901-0....
• 1.5 m
6XV1 830-1CH15
for SIMATIC S7
MPI cable between
SIMATIC S7 and programming
device via MPI max. 187.5 kbaud
• 3.0 m
6XV1 830-1CH30
Standard length
• 5.0 m 2)
6ES7 901-0BF00-0AA0
1)
Included in OP3 scope of delivery
2)
Included in PG scope of delivery
2/162
Siemens ST 80 · 2009
Note:
See appendix for connecting cable length codes.
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Connecting cables
■ Ordering data
Order No.
Order No.
Configuration cable 6ES5 734
RS 232/PPI multi-master cable
6ES7 901-3CB30-0XA0
for connecting PG 7xx to
SIMATIC S5-90U to S5-155U
via 25-pin socket/TTY (serial)3)
USB/PPI multi-master cable
6ES7 901-3DB30-0XA0
• 5.0 m
6ES5 734-2BF00
• 10.0 m
6ES5 734-2CB00
Custom lengths
• max. 1000.0 m
2
For connecting the S7-200 to the
serial PC/OP interface
Standard lengths
6ES5 734-2...0
Configuration cable 6ES7
for connecting PC/PG/OP/TD to
SIMATIC S7-200/300/400
via 9-pin male/RS232 (serial)
PROFIBUS FC Standard Cable
6XV1 830-0EH10
For connection to PPI;
standard type with special design
for quick mounting, 2-core,
shielded, sold by the meter, max.
delivery unit 1000 m, minimum
ordering quantity 20 m
Industrial Ethernet TX XP Cord
RJ45/RJ45
• between PG 702/OP31) and
S7-200/300/400 via PPI/MPI
6ES7 705-0AA00-7BA0
• between
OP7/OP17/OP272)/TD17 and
S7-200/300/400 via MPI
6ES7 901-0BF00-0AA0
Connecting cable 6ES7 901
Crossed TP cable 4 x 2,
preassembled with 2 x RJ45
connectors
• 1.0 m
6XV1 870-3RH10
• 6.0 m
6XV1 870-3RH60
• 10.0 m
6XV1 870-3RN10
between HMI adapter and PC/TS
adapter
(RS232/null MODEM cable)
for OP77B, TP 177A, TP 170B, OP
170B, TP/OP 270, MP 270,
MP 370
• 5.0 m
6ES7 901-1BF00-0XA0
1)
Included in OP3 scope of delivery
Note:
2)
Included in PG scope of delivery
3)
Except OP3 and OP7/DP
See appendix for connecting cable length codes.
Cable assignments can be found on the Internet in the online
help of ProTool and WinCC flexible and under FAQs
Siemens ST 80 · 2009
2/163
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Bus connector RS485
■ Overview
■ Ordering data
RS485 bus connector with
axial cable outlet (180°)
Order No.
6GK1 500-0EA02
For industrial PC, SIMATIC HMI
OP, OLM; max. transmission rate
12 Mbit/s
2
RS485 bus connector
with cable outlet (90°)
With screw-terminals, max.
transmission rate 12 Mbit/s
• Without programmer port
6ES7 972-0BA12-0XA0
• With programmer port
6ES7 972-0BB12-0XA0
RS485 bus connector with
angled cable outlet (35°)
With screw-terminals, max.
transmission rate 12 Mbit/s
• Used for connecting PROFIBUS nodes to the PROFIBUS bus
cable
• Easy installation
• FastConnect plugs ensure extremely short assembly times
due to their insulation-displacement technology
• Integrated terminating resistors
(not in the case of 6ES7 972-0BA30-0XA0)
• PG connection with special bus connector possible without
additional installation of network nodes.
• Without PG interface
6ES7 972-0BA41-0XA0
• With PG interface
6ES7 972-0BB41-0XA0
RS485 bus connector with
cable outlet (30°)
6ES7 972-0BA30-0XA0
With screw-terminals, low-cost
variant, max. transmission rate
1.5 Mbit/s
PROFIBUS bus connector RS485 with FastConnect technology
PROFIBUS FastConnect bus
connector RS485 with 90° cable
outlet
With insulation displacement
terminals, max. transmission rate
12 Mbit/s
• Without PG interface
6ES7 972-0BA51-0XA0
• With PG interface
6ES7 972-0BB51-0XA0
PROFIBUS FastConnect RS485
bus connector with angled
cable outlet (35°)
With insulation displacement
terminals, max. transmission rate
12 Mbit/s
• Without PG interface
6ES7 972-0BA60-0XA0
• With PG interface
6ES7 972-0BB60-0XA0
PROFIBUS FastConnect bus
connector RS485 Plug 180
6GK1 500-0FC10
With insulation displacement
terminals, with 180° cable outlet,
for industrial PC, SIMATIC HMI
OP, OLM; max. transmission rate
12 Mbit/s
Electronic manuals for communication systems, communication
protocols, and communication
products; on DVD;
German/English
2/164
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
IE FC RJ45 Plug 2 x 2
■ Overview
■ Ordering data
Order No.
IE FC RJ45 plugs
RJ45 plug connector for Industrial
Ethernet with a rugged metal
housing and integrated insulation
displacement contacts for connecting Industrial Ethernet FC
installation cables
2
IE FC RJ45 Plug 180
180° cable outlet; for network
components and CPs/CPUs with
Industrial Ethernet interface
• 1 pack = 1 item
6GK1 901-1BB10-2AA0
• 1 pack = 10 items
6GK1 901-1BB10-2AB0
• 1 pack = 50 items
6GK1 901-1BB10-2AE0
IE FC RJ45 Plug 90
90° cable outlet; e.g. for
ET 200S
• Implementation of direct device connections over distances of
up to 100 m with Industrial Ethernet FC installation cable 2 x 2
without patching
• Easy connection (insulation displacement contacts) for 4-core
Twisted Pair installation cables (100 Mbit/s) without the need
for special tools
• Error-preventing connection technique thanks to visible
connection area as well as colored blade terminals
• Industry-compatible design (rugged metal housing, no easily
lost small parts)
• Excellent EMC shielding and deflection (metal housing)
• Integrated strain-relief for installation cables
• Compatible to the EN 50173 (RJ45) / ISO IEC 11801 standard
• Additional strain and bending relief of plug connector possible
through latching of plug on device housing, e.g. with
SCALANCE X, SCALANCE S, ET 200S.
• 1 pack = 1 item
6GK1 901-1BB20-2AA0
• 1 pack = 10 units
6GK1 901-1BB20-2AB0
• 1 pack = 50 units
6GK1 901-1BB20-2AE0
IE FC RJ45 Plug 145
145° cable outlet; e.g. for
SIMOTION and SINAMICS
• 1 pack = 1 item
6GK1 901-1BB30-0AA0
• 1 pack = 10 units
6GK1 901-1BB30-0AB0
• 1 pack = 50 units
6GK1 901-1BB30-0AE0
IE FC TP Standard Cable GP
2 x 2 (Type A)
4-core, shielded TP installation
cable for connection to IE
FC Outlet RJ45/ IE FC RJ45 Plug;
PROFINET-compatible; with UL
approval;
Sold by the meter
max. quantity 1,000 m; minimum
order 20 m
6XV1 840-2AH10
Preferred length
• 1000 m
6XV1 840-2AU10
IE FC TP Flexible Cable GP
2 x 2 (Type B)
6XV1 870-2B
4-core, shielded TP installation
cable for connection to IE
FC Outlet RJ45/ IE FC RJ45 Plug
for occasional movement;
PROFINET-compatible; with UL
approval;
sold by the meter; max. quantity
1000 m, minimum order 20 m
4-core, shielded TP installation
cable for connection to IE
FC Outlet RJ45/ IE FC RJ45 Plug
180/90 for use in trailing cables;
PROFINET-compatible; without
UL approval;
sold by the meter; max. quantity
1000 m, minimum order 20 m
Siemens ST 80 · 2009
2/165
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Accessories for SIMATIC Mobile Panels
■ Overview
■ Ordering data
Order No.
Connecting cable DP (MPI/
PROFIBUS) for Mobile Panels
Standard lengths
2
•2m
6XV1 440-4AH20
•5m
6XV1 440-4AH50
• 10 m
6XV1 440-4AN10
• 15 m
6XV1 440-4AN15
• 25 m
6XV1 440-4AN25
Custom lengths 1)
•8m
6XV1 440-4AH80
• 20 m
6XV1 440-4AN20
Connecting cable PN
(PROFINET) for Mobile Panels
Standard lengths
Connecting cable PB (PROFIBUS) for Mobile Panels
•2m
6XV1 440-4BH20
•5m
6XV1 440-4BH50
•8m
6XV1 440-4BH80
• 10 m
6XV1 440-4BN10
• 15 m
6XV1 440-4BN15
• 20 m
6XV1 440-4BN20
• 25 m
6XV1 440-4BN125
Wall-mounting bracket for
Mobile Panels
6AV6 574-1AF04-4AA0
1)
Connecting cable PN (PROFINET) for Mobile Panels
Extended delivery time
■ Dimensions
18
24.6
Wall-mounting bracket for Mobile Panel, front view/side view
2/166
Siemens ST 80 · 2009
Wall-mounting bracket for SIMATIC Mobile Panel
2
G_ST80_XX_00047
8°
100.7
225.2
8°
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Accessories for SIMATIC Mobile Panels
■ Overview (cont.)
■ Ordering data
Service pack for Mobile
Panels 177/277
Order No.
6AV6 574-1AA04-4AA0
Consisting of:
2
• Blanking plugs for cable duct
• 2 x cable glands for connectivity
box
• 1 set of screws for connectivity
box cover
• 2 x terminal box (12-pin)
• 1 x terminal box (3-pin)
• 1 x blanking cap for connectivity
box
Service pack for Mobile Panels
277(F) IWLAN
6AV6 671-5CA00-0AX1
Consisting of:
Service pack for Mobile Panels
• 1 x Mobile Panel 277
accessories pack (labeling
strip cover)
• 1 x battery slot cover (device)
• 1 x backup battery
• 1 x left/right cover (charging
station)
• 1 x power supply mating
connector (charging station)
• 1 x spare key (charging station)
Spare keys for Mobile Panels
6AV6 574-1AG04-4AA0
(pack of 10 keys)
Accumulator option pack for
Mobile Panels (DP and PN)
6AV6 671-5AD00-0AX0
Touch pen
including nylon line for securing it
to the Mobile Panel 277 10" (set of
5, packed ready for shipping)
6AV6 645-7AB14-0AS0
Battery for Mobile Panel 277(F)
IWLAN
6AV6 671-5CL00-0AX0
Spare keys for Mobile Panels
Option pack: accumulator for Mobile Panels
Siemens ST 80 · 2009
2/167
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Accessories for SIMATIC Mobile Panels –
connection boxes
■ Overview
2
Connection boxes DP and PN
■ Technical specifications
Connection box DP for Mobile Panels 177/277
(MPI/PROFIBUS)
Connection box DP for Mobile Panels 177/277
(PROFINET)
Basic
Plus
Basic
Plus
Supply voltage
24 V DC
24 V DC
24 V DC
24 V DC
permissible range
+20.4 V to +28.8 V DC
+20.4 V to +28.8 V DC
+20.4 V to +28.8 V DC
+20.4 V to +28.8 V DC
Rated current
0.4 A
0.5 A
0.4 A
0.5 A
Power
10 W
12 W
Hot swapping
with emergency stop
circuit interruption
without emergency stop
circuit interruption
with emergency stop
circuit interruption
without emergency stop
circuit interruption
• Monitoring the STOP
button
No
Yes
No
Yes
• Location identifier
Yes
Yes
Yes
Yes
85%
85%
85%
85%
• Operation
(vertical installation)
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
• Transport, storage
-20 °C to +70 °C
-20 °C to +70 °C
-20 °C to +70 °C
-20 °C to +70 °C
IP65
IP65
IP65
IP65
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
1 x RS232, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)
1 x RS232, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)
2 x Ethernet (RJ45)
2 x Ethernet (RJ45)
Yes
Yes
Yes
Yes
160 x 120 x 70
160 x 120 x 70
230 x 120 x 80
230 x 120 x 80
0.35 kg
0.4 kg
0.45 kg
0.5 kg
Expansions to operator
processcommunication
Ambient conditions
max. relative humidity
(in %)
Temperature
Degree of protection
Enclosure according
to EN 60529
Certifications & Standards
Certifications
interfaces
Interfaces
Functionality under
WinCC flexible
• Connection point
identification
Dimensions
External dimensions
(W x H x D) in mm
Weights
Weight
2/168
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Accessories for SIMATIC Mobile Panels –
connection boxes
■ Dimensions
■ Ordering data
Order No.
DP junction box for
Mobile Panels 177/277
(MPI/PROFIBUS)
140
62,7
43
10
• Basic
• Plus
2
6AV6 671-5AE00-0AX0
A
6AV6 671-5AE10-0AX0
• Basic
A
6AV6 671-5AE01-0AX0
• Plus
A
6AV6 671-5AE11-0AX0
PN junction box for
Mobile Panels 177/277
(PROFINET)
160
150
G_ST80_XX_00045
11 0
120
142 ± 2
A) Subject to export regulations: AL: N and ECCN: EAR99H
DP connection box for SIMATIC Mobile Panel
230
220
110
120
142 ± 2
55
4,5
G_ST80_XX_00273
76
10
210
PN connection box for SIMATIC Mobile Panel
Siemens ST 80 · 2009
2/169
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Accessories for SIMATIC Mobile Panels –
charging station
■ Overview
■ Dimensions
85
2
Supply voltage
24 V DC
Permissible range
+19.2 V to +28.8 V DC
Rated current
3.2 A
Power
77 W
72
208
Ambient conditions
Max. relative humidity (in %)
85%
Temperature
• Operation (vertical installation)
0 °C to +40 °C
• Transport, storage
-20 °C to +60 °C
Degree of protection
IP65 at front
Yes
IP65 rear
Yes
Enclosure according to EN 60529 IP65
Certifications & Standards
Certifications
CE, cULus, C-TICK
Dimensions
External dimensions (W x H x D)
in mm
208 x 333 x 75
Weights
• Weight
2/170
1.1 kg
Siemens ST 80 · 2009
■ Ordering data
Charging station for Mobile
Panels
Order No.
6AV6 671-5CE00-0AX0
G_ST80_XX_00297
6AV6 671-5CE00-0AX0
61
■ Technical specifications
198
343
160
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Accesories for SIMATIC Mobile Panels –
Transponder
■ Dimensions
2
45
90
■ Overview
172
■ Technical specifications
■ Ordering data
6AV6 671-5CM00-0AX0
Supply voltage
Via battery
Yes
• Number of batteries
3
• Battery type
- Type AA
Type AA
• Lifetime of battery, typ.
5 at
Transponder for
Mobile Panels 277
G_ST80_XX_00298
38,5
162
Order No.
6AV6 671-5CM00-0AX0
Yes
Ambient conditions
Max. relative humidity (in %)
85%
Temperature
• Operation (vertical installation)
0 °C to +50 °C
• Transport, storage
-20 °C to +60 °C
Degree of protection
IP65 at front
Yes
NEMA
4x / 12
IP65 rear
Yes
Enclosure according to EN 60529 IP65
Enclosure according to NEMA
NEMA 4x, NEMA 12
Certifications & Standards
Certifications
CE, cULus, C-TICK, NEMA 4x,
NEMA 12
Transponder
Transmit frequency
2.4 gHz; Passive, frequency
range: 2400 to 2483.5 MHz
Range of transmitter
8m
Transmission angle
93°
Number of adjustable identifiers,
max.
65 534
Functionality under
WinCC flexible
Zones
Yes
Effective range
Yes
Dimensions
External dimensions
(W x H x D) in mm
172 x 90 x 38.5
Weights
Weight
0.3 kg
Siemens ST 80 · 2009
2/171
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Memory cards
■ Overview
■ Ordering data
Order No.
Memory cards
2
PC card adapter with Compact Flash Card
Multi Media Card / SD Card
CompactFlash Card
USB 2.0 memory stick (USB Flash Drive)
2/172
Siemens ST 80 · 2009
PC Card, 512 MB, comprising:
PC card adapter with Compact
Flash Card 512 MB for MP 370
A
6AV6 574-2AC00-2AF1
Multi Media Card, 128 MB for
Mobile Panel 177, OP 77B,
TP/OP 177B, TP/OP 277
A
6AV6 671-1CB00-0AX2
SD card, 256 MB for Mobile
Panel 277, MP 177, MP 277,
MP 377
A
6AV6 671-8XB10-0AX0
Compact Flash Card, 512 MB for
Mobile Panel 170, TP/OP 170B,
TP/OP/MP 270, MP 370, MP 377
and C7-635, C7-636
6AV6 574-2AC00-2AA1
USB 2.0 memory stick (USB Flash A
Drive) with 2 GB memory
for Mobile Panel 277, OP 77B,
TP/OP 177B, TP/OP 277, MP 177,
MP277 and MP 377
6ES7 648-0DC40-0AA0
A) Subject to export regulations: AL: N and ECCN: EAR99H
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Converters/adapters
■ Overview
■ Ordering data
Order No.
Converter
RS232 to TTY converter, 20 mA
between TD/OP/TP and S5-90U to
S5-155U, for TP/OP 170B, TP/OP
270, MP 270B
6ES5 734-1BD20
2
RS422 to RS232 converter, V.24
A
between TD/TP/OP and nonSiemens PLC with RS232
interface, for TP 177B, OP 177B,
TP/OP 277-6, MP 277-8T/K,
MP 277-10T/K
6AV6 671-8XJ00-0AX0
90° angle adapter, 1:1
6XV1 440-2DE32
between TD/OP and connecting
cable
Converter RS422/485
6AV6 671-8XD00-0AX0
A) Subject to export regulations: AL: N and ECCN: EAR99H
PC converter, RS232 to TTY
90° angle adapter, 1:1
RS422/485 converter
Siemens ST 80 · 2009
2/173
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Service packs
■ Overview
■ Ordering data
Service pack for PP7/17
Order No.
6AV3 678-3XC30
Consisting of:
• 1 x PP7 gasket
2
• 1 x PP17-I/PP17-II gasket
• 5 x tensioning clamps
• 1 x PP7 plug-in terminal strip
(2-pin)
• 1 x 24 V PP17-I/PP17-II plug-in
terminal strip (3-pin)
Service pack for OP 73micro,
OP 73, OP 77A/B,
6AV6 671-1XA00-0AX0
Consisting of:
• 2 x mounting seals
• 4 x tensioning clamps
• 1 x 24 V plug-in terminal strip
(twin block)
The service packs listed below are available:
• PP7/17
• TD 17, OP 7, OP 17
• OP 73micro, OP 73, OP 77A/B
• TP 170micro, TP 070, TP 170A/B, OP 170B, TP 270 6",
OP 270 6", MP 177 6" Touch, MP 277 8" Touch
• MP 370 Touch, TP 270 10", C7 636 Touch
• TP 177micro, TP 177A, TP/OP 177B
• Mobile Panels 177/277
• Mobile Panels 277(F) IWLAN
• OP 270 10"
• MP 277 series
• MP 277 10" Touch INOX
• MP 370 Key, MP 377 Key
• MP 377 Touch
• Industrial USB Hub 4
• Power supply connector set
2/174
Siemens ST 80 · 2009
Service pack for TP 170micro,
TP070, TP 170A/B,
OP 170B, TP 270 6", OP 270 6",
MP 177 6" Touch, MP 277 8"
Touch
6AV6 574-1AA00-4AX0
Consisting of:
• Mounting seals
• 2 x sets of labeling strips for OPs
• 7 x tensioning clamps
• 1 x 24 V plug-in terminal strip
(twin block)
Service pack for TP 177micro,
TP 177A, TP/OP 177B
Consisting of:
• 2 x mounting seals
• 7 x tensioning clamps
• 1 x 24 V plug-in terminal strip
(twin block)
6AV6 671-2XA00-0AX0
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Service packs
■ Ordering data (continued)
Service pack for Mobile Panels
177/277
Order No.
6AV6 574-1AA04-4AA0
Consisting of:
• Blanking plugs for cable duct
6AV6 675-3AA00-0AX0
Service pack for MP 370 Keys/
MP 377 Keys
6AV6 574-1AA00-2BX0
• 1 x mounting seal
• 1 set of screws for connectivity
box cover
• 2 x sets of labeling strips for OPs
• 7 x tensioning clamps
• 2 x terminal box (12-pin)
• 1 x 24 V plug-in terminal strip
(twin block)
• 1 x terminal box (3-pin)
• 1 x blanking cap for connectivity
box
• 1 x socket wrench
6AV6 671-5CA00-0AX1
Service pack for MP 377 Touch A
6AV6 671-4XA00-0AX0
Service pack for Industrial USB
Hub 4
6AV6 671-3EA01-0AX0
Consisting of:
Consisting of:
• 1 x Mobile Panel 277
accessories pack (labeling
strip cover)
• 1 x mounting seal
• 1 x battery slot cover (device)
• 1 x rear metal frame (for achieving IP65 with mounting plates
that are less than 3 mm thick)
• 1 x backup battery
• 5 x tensioning clamps
• 1 x left/right cover (charging
station)
• 1 x 24 V plug-in terminal strip
(twin block)
• 1 x 24 V power supply mating
connector (charging station)
Key labeling strips MP 370
Keys/ MP 377 Keys
• 1 x spare key (charging station)
Service pack for MP 277 series
2
Consisting of:
• 2 x cable glands for connectivity
box
Service pack for Mobile Panels
277(F) IWLAN
Order No.
Service pack for MP 277 10"
Touch INOX
6AV6 671-3XA01-0AX0
Consisting of:
• 1 x mounting seal
• 10 x tensioning clamps
6AV6 574-1AB00-2BA0
for function keys, without labeling,
2 sets each (plastic)
Key labeling strips for Mobile
Panel 277
6AV6 671-5BF00-0AX0
Packet for labelling 6 devices
(2 sheets per set) incl. spare
stickers for cover caps
• 1 x 24 V plug-in terminal strip
(twin block)
Power supply connector set
• 1 x socket wrench
Consisting of:
6AV6 671-8XA00-0AX0
• 10 x 2-pole 24 V DC power
supply connectors
A) Subject to export regulations: AL: N and ECCN: EAR99H
Siemens ST 80 · 2009
2/175
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Protective covers
■ Overview
■ Ordering data
Protective covers for
TP 070, TP 170micro, TP
177micro,
TP 170A/B, TP 177A/B,
TP 270 6", TP 277 6"
MP 177 6" Touch,
MP 270 6"Touch
2
Order No.
6AV6 574-1AE00-4AX0
(2 sets)
Consisting of:
• 2 cover frames
• 2 base frames
• 2 protective covers, molded
(for TP 070, TP 170micro, TP
170A/B)
• 2 protective covers smooth
(for TP 177micro, TP 177A/B,
TP 270 6", MP 177 6" Touch,
MP 270 6" Touch)
Protective covers for:
• TP 070, TP 170micro, TP 177micro, TP 170A/B, TP 177A/B,
TP 270 6", TP 277 6", MP 177 6" Touch, MP 270B 6" Touch
• OP 77 A/B
• OP 177B
• MP 277 8" Touch
• MP 277 10" Touch, THIN CLIENT 10"
Protective covers for OP 77A/B
6AV6 671-1AJ00-0AX0
(2 sets)
Consisting of:
• 2 cover frames
• 2 base frames
• 2 protective covers
Protective covers for OP 177B
6AV6 671-2DJ00-0AX0
(2 sets)
Consisting of:
• 2 cover frames
• 2 base frames
• 2 protective covers
Protective covers for MP 277 8"
Touch
6AV6 671-3CK01-0AX0
(2 sets)
Consisting of:
• 2 cover frames
• 2 base frames
• 2 protective covers
Protective covers for MP 277
10" Touch, THIN CLIENT 10"
(2 sets)
Consisting of:
• 2 cover frames
• 2 base frames
• 2 protective covers
2/176
Siemens ST 80 · 2009
6AV6 671-3CK00-0AX0
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Cover foils
■ Overview
■ Ordering data
Order No.
Blank faceplates for TD 100C
6ES7 272-1BF00-7AA0
For printing customized keyboard layouts; 6 perforated foils
per sheet; 10 sheets per packing
unit
Blank faceplates for TD 200C
A
2
6ES7 272-1AF00-7AA0
For printing customized keyboard layouts; 3 perforated foils
per sheet; 10 sheets per packing
unit
Cover foil for TP 070,
TP 170micro, TP 170A/B
6AV6 574-1AD00-4AX0
(pack of 10 each)
Cover foil for TP 177micro, TP
177A/B, OP 177B
6AV6 671-2XC00-0AX0
(pack of 10 each)
Cover foil for Mobile Panel 177
Cover foils for:
• TD 100C
• TD 200C
• TP 070, TP 170micro, TP 170A/B
• TP 177micro, TP 177A/B, OP 177B
• Mobile Panel 177
• Mobile Panel 277 8", Mobile Panel 277 10"
• TP 270 6", TP 277 6", MP 177 6" Touch, MP 270B 6" Touch
• TP 270 10", MP 270B 10", MP 370 12" Touch, MP 377 12" Touch
• MP 277 8" and 10", THIN CLIENT 10"
• MP 370 15" Touch, MP 377 15" Touch, THIN CLIENT 15"
• MP 377 19" Touch
6AV6 574-1AD04-4AA0
(pack of 10 each)
Cover foil for
Mobile Panel 277 8"
6AV6 671-5BC00-0AX0
Tough film to protect the touch
display from dirt and scratches
(set of 2)
Cover foil for
Mobile Panel 277 10"
6AV6 645-7AB15-0AS0
Tough film for protection against
dirt and scratches (set of 10,
packed ready for shipment)
Cover foil for TP 270 6",
TP 277 6", MP 177 6" Touch,
MP 270B 6" Touch
6AV6 574-1AD00-4DX0
(pack of 10 each)
Cover foil for TP 270 10",
MP 270B 10",
MP 370 12" Touch,
MP 377 12" Touch
6AV6 574-1AD00-4CX0
(pack of 10 each)
Cover foil for MP 277 8"
Cover foil for MP 277 10" Touch,
THIN CLIENT 10"
For protection of the touch front
against fouling/scratching (set of
10 each)
• for MP 277 8" Touch
6AV6 671-3CC00-0AX0
• for MP 277 10" Touch, THIN
CLIENT 10"
6AV6 671-3DC00-0AX0
Cover foil for MP 370 15" Touch,
MP 377 15" Touch, THIN CLIENT
15"
6AV6 574-1AD00-4EX0
(pack of 10 each)
Cover foil for MP 377, 19" Touch
6AV7 672-1CE00-0AA0
Protective pocket for labeling
strips for Mobile Panel 170
and 177
6AV6 574-1AB04-4AA0
(5 items) for labelling strips for
Mobile Panel 177 and 277
A) Subject to export regulations: AL: N and ECCN: EAR99H
Siemens ST 80 · 2009
2/177
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Clamping frame
■ Overview
■ Ordering data
Order No.
Clamping frame for
2
• MP 277 8" Touch
6AV6 671-3CS00-0AX0
• MP 277 8" Key
6AV6 671-3CS01-0AX0
• 10"/12" Touch
6AV6 671-8XS00-0AX0
Can be used for:
KTP1000, MP 277 10" Touch,
MP 377 12" Touch,
THIN CLIENT 10"
The clamping frames enable compliance with degrees of protection IP65, NEMA4X and NEMA12 (indoor only) if the thickness
of the mounting plate is less than the minimum plate thickness
specified in the manual. The clamping frame has been specially
developed for plate thicknesses of less than 2 mm.
For the THIN CLIENT 10" Touch, the clamping frame is needed
for plate thicknesses of less than 2 mm, for both IP54 and for
IP65.
The clamping frames are available for the following products:
• KTP1000 Basic color
• SIMATIC MP 277 8" Touch
• SIMATIC MP 277 8" Key
• SIMATIC MP 277 10" Touch
• SIMATIC MP 377 12" Touch
• SIMATIC THIN CLIENT 10" Touch
2/178
Siemens ST 80 · 2009
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Back-up battery and accumulator
■ Overview
■ Ordering data
Backup battery
Order No.
W79084-E1001-B2
Lithium battery, 3.6 V DC;
1.7 Ah; for
TD17,OP17, OP25, OP27, OP
270, OP35, OP37, TP27, TP 270,
TP37, MP 270, MP 270B and MP
370
Additional battery for Mobile
Panel 227F IWLAN
2
6AV6 671-5CL00-0AX0
Additional battery with LED
indicator for indicating the
charge status
Rechargeable battery
6AV6 671-5AD00-0AX0
for Mobile Panel (PN and DP)
177/277
Table-top power supply for
Mobile Panel 277F IWLAN
Backup battery
6AV6 671-5CN00-0AX1
Table-top power supply incl.
power cable for EU, US, UK, JP
(only suitable for operation
under laboratory/office
conditions)
Note: Please order the table-top
power supply or charging station
as well. Required for charging the
battery:
Rechargeable battery
Siemens ST 80 · 2009
2/179
© Siemens AG 2008
Operator Control and Monitoring Devices
HMI Accessories
Recommended printers for Panels and
Multi Panels
■ Overview
Print functions of SIMATIC HMI Panels
2
OP 77B
Hardcopy
Print log1)
Alarm log
On/Off
Print fault
message
buffer
Event
message
buffer
Event
Print data
record with record
filter
Print all
data
records
Header/
footer
n
n
n
n2)
n2)
n2)
n2)
n2)
n2)
2)
2)
2)
2)
2)
OP/TP 177B
n
n
n
n
n
n
n
n
n2)
OP/TP 277
n
n
n
n2)
n2)
n2)
n2)
n2)
n2)
MP 277
n
n
n
n2)
n2)
n2)
n2)
n2)
n2)
n
2)
2)
2)
2)
2)
n2)
n
MP 377
n
n
n
n
n
n
n Functionality possible
1)
Variable, messages, recipes
2)
Included in log
Note:
The OP 73micro, OP 73, OP 77A, TP 177micro and TP177A do
not include a printer interface
Approved printers, sources of supply and
printer settings
You will find an overview of approved printers, sources or supply
and printer settings in the Internet at
Additional information is available in the Internet at:
http://support.automation.siemens.com/WW/view/de/11376409
Printers and printer settings
Additional information is available in the Internet under:
http://www4.ad.siemens.de/news/csi/com/11376409
■
2/180
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
3/2
3/2
3/5
3/13
3/18
Introduction
Overview
SIMATIC Panel PC 477B embedded
SIMATIC Panel PC 577B
SIMATIC Panel PC 677B (incl. INOX)
3/28
3/28
3/29
3/30
3/32
3/34
3/35
Expansions components
SIMATIC PC DiagMonitor
SIMATIC PC BIOS-Manager
SIMATIC PC Image Creator
SIMATIC PC Partition Creator
SIMATIC PC USB FlashDrive
SINUMERIK 3,5" floppy disk drive,
USB 1.1
SIMATIC Panel PC Remote Kit
Industrial USB Hub 4
3/36
3/38
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
Introduction
■ Overview
SIMATIC Panel PC 477B embedded
Ultra-compact and maintenance-free Panel PC in embedded
technology
• Only 75 mm mounting depth (19" display: 98 mm)
• No rotating parts (without fan and hard disk)
• High security due to the Microsoft Windows XP embedded
operating system
• Ready-to-use devices with optionally preinstalled software
- HMI: Innovative HMI software WinCC flexible (incl. archives
and recipes)
- RTX: with real-time capable software PLC WinAC RTX
• Expandable with PC/104 (+) plug-in cards
• Retentive memory on board
(NV-RAM, usable with WinAC RTX)
3
SIMATIC Panel PC 577B
SIMATIC Panel PCs are suitable thanks to their high industrial
compatibility both for use in control cabinets, consoles and
control panels, as well as directly on the machine. Typical areas
of application can be found in both production and process
automation.
There is a broad range of robust, high-performance SIMATIC
Panel PCs available for different requirements.
Shared industrial functionality
• High-quality components and modules with a high MTBF
(mean time between failure), which also ensure 24-hour
operation in the extended temperature range.
• High swing/shock capacity of the devices through special
hard-disk suspensions, locked connectors and card retainers
• Rugged housing model with high electromagnetic compatibility (EMC) and integrated industrial power supplies (also as
per NAMUR)
• Service-friendly device design
• Bright, brilliant displays in different sizes up to 19"
• Same front panel mounting dimensions and uniform front
design across all device families
• Rugged fronts protected from dust, humidity and chemical
substances (front-side IP65 / NEMA 4 degrees of protection)
3/2
Siemens ST 80 · 2009
Industrial functionality and openness at an attractive price
• All versions available from stock
• Rugged design for industrial use
• Can be expanded using PCI slots and further ports
SIMATIC Panel PC 677B
Flexibility and compactness with maximum performance
• High performance thanks to latest process technology from
Intel
• Dual Core technology: up to Intel Core 2 Duo 2.16 GHz
• Compact structure with simultaneous expandability through
PCI/PCIe slots
• Strong communication through two Ethernet and integrated
PROFIBUS DP/MPI interfaces
• Control and computer units can be separated by up to 30 m
• RAID1 controller on board
• Retentive memory on board
(NV-RAM, usable with WinAC RTX)
© Siemens AG 2008
SIMATIC Panel PC
Introduction
■ Overview (continued)
SIMATIC Panel PC 477B
embedded
SIMATIC Panel PC 577B
SIMATIC Panel PC 677B
Centralized configuration
I
I
I
Distributed configuration (via remote kit)
–
–
I2)
Size
12"/15"/19" TFT
12"/15"/19" TFT
12"/15"/15" INOX/17”/19” TFT
Resolution
800 x 600/
1024 x 768/
1280 x 1024
800 x 600/
1024 x 768/
1280 x 1024
800 x 600/
1024 x 768/
1280 x 1024
Membrane keyboard
I1)
–
I1)
Touch screen
I
I
I
Power supply
24 V DC / 110/230 V AC
I/–
–/I
I/I
Processor
Intel Celeron M 1.0 GHz;
Intel Pentium M 1.4 GHz
Intel Celeron M 1.86 GHz
Intel Celeron M 1.86 GHz;
Intel Core 2 Duo 1.66 GHz;
Intel Core 2 Duo 2.16 GHz
Main memory
1 GB or 2 GB
1 GB, expandable to 4 GB
1 GB; 2 GB;
3 GB; 4 GB
Expansion slots
3 x PC/1042);
2 x CF slot
(1 x accessible from outside)
2 x PCI3);
1 x CF slot
(externally accessible)
2 x PCI or 1x PCI and
1x PCIe x43); 1 x CF slot
Operating system
Windows XP embedded
on CF Card
None;
Windows XP Professional MUI
None;
Windows 2000 Professional MUI;
Windows XP Professional MUI;
Windows Vista Ultimate MUI;
Windows XP embedded on CF
I
–4)
I
PROFINET
I
–4)
I
Ethernet
10/100/1000 Mbit
10/100/1000 Mbit
10/100/1000 Mbit
PS/2 (mouse /keyboard)
–
–
–
USB
I
I
I
Serial interface
I
I
I
Parallel interface
–
–
–
Audio in/out
–
–
–
Graphics interface
I
I
I
Vibration load during operation
1g
0.25 g
1g
Shock loading during operation
5g
1g
5g
+5 °C … +50 °C5)
+5 °C … +50 °C5)
140 W7)
140 W7)
W7)
163 W7)
Design
Display
3
Operator controls
General features
Interfaces
PROFIBUS/MPI
Ambient conditions
Permissible temperature during operation with +5 °C … +50 °C
maximum configuration
Power loss in maximum configuration
12"/15" display
17"/19" display
80 W6)
110
W6)
163
I Available
– Not available
1)
12"/15" displays
2)
With optional expansion rack
3)
All slots with card retainer
4)
Expandable via plug-in card
5)
With 17"/19" Touch: max. 50 °C in installation space,
max. 40 °C at the front
6)
3 W taken into account for each PC/104 slot
7)
15 W taken into account for each PCI/PCIe slot
Siemens ST 80 · 2009
3/3
© Siemens AG 2008
SIMATIC Panel PC
Introduction
■ Benefits
High degree of industrial capability
Extendibility
The entire construction is designed for purely industrial use.
Thus, for example, a special vibration-absorbing suspension of
the hard disk ensures operational reliability, even at high
mechanical loads. SIMATIC Panel PCs are thus designed for a
vibration load of 1 g (Panel PC 577: 0.25 g) and a shock load of
5 g (Panel PC 577: 1 g) during operation.
Depending on the model, ISA, PCI, PCI Express, PC/104 Plus
and PC/104 slots are available for individual expandability. This
enables the further use of existing and new expansion cards.
Performance
3
Thanks to the use of the latest Intel processors from ULV (Ultra
Low Voltage) to Core 2 Duo technology, SIMATIC Panel PCs are
flexibly scalable for your application.
• Scalable computing power
• Highest computing power
• Latest Intel processor technology
• Dual Core, ULV
Investment security
High component continuity and guaranteed availability of spare
parts for up to 5 years after product phase-out are ensured e.g.
through the development and production of our own motherboards. This enables long-lasting machine concepts without
renewed engineering effort.
Service-friendly device design
Upgrades and exchange of components are easy thanks to the
device design.
Integrated interfaces
The different already-integrated interfaces allow for various
communication and expansion options. Many models are
already equipped with Gigabit Ethernet and PROFIBUS DP/MPI
interface.
3/4
Siemens ST 80 · 2009
Compact dimensions
Considering the desired expandability, SIMATIC Panel PCs have
an extremely low mounting depth and can thus be used in very
narrow installation locations.
Options
Various options enable an individual solution for your industrial
application. Thus, the operator control unit can be operated
separately from the computer unit by up to 30 m. The direct
control key module increases the operating safety in that it can
be used to run the process independently of the operating
system and without delay directly on PROFIBUS DP/MPI.
Individually expandable system availability
• RAID1 configuration – high system stability through redundant
data management
• SIMATIC PC DiagMonitor – Monitoring of the operating states
and early detection of problems locally and in the network
• SIMATIC PC/PG Image & Partition Creator – downtime
minimization through preventative data backup
• SITOP and Masterguard power supply (UPS) – Bridging of
voltage dips
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 477B embedded
■ Overview
• Embedded PC platform with extremely high industrial
compatibility for demanding tasks in the field of PC-based
automation
• Maintenance-free (no rotating components such as fan and
hard disk)
• Rugged construction: The PC is resistant to the harshest
mechanical stress and is extremely reliable in operation
• Compact structure (only 75 mm mounting depth for 12"/15")
• High degree of investment protection
• Fast integration capability
• Front panel versions:
- 12" and 15" TFT Touch
- 12" and 15" TFT Key
- 19" Touch
■ Benefits
• Excellent industrial compatibility due to rugged construction,
even when subjected to extreme vibration and shock
• High level of investment security thanks to assured spare
parts availability of the components (for 5 years following the
end of active marketing)
• Excellent continuity of components for machine concepts with
a long service life without any new engineering costs
• Savings in time and costs due to service-friendly equipment
construction:
- Front and rear USB 2.0 interfaces for quick and easy
connection of additional hardware components
• High degree of industrial functionality thanks to integrated
PROFIBUS DP/MPI and Ethernet interfaces
• Maintenance-free due to lack of rotating components (fan and
hard disk)
• Reduction in standstill times thanks to high system availability
- Efficient self-diagnostics (SIMATIC PC DiagMonitor)
- High reliability and security of an embedded platform
• Integral part of Totally Integrated Automation (TIA):
- Enhanced productivity, reduction of engineering costs,
reduction of lifecycle costs
• Turnkey complete solution is supplied (the software is already
installed and preconfigured) for visualization and automation
in combination with WinCC flexible and WinAC RTX.
■ Application
SIMATIC Panel PC 477B embedded is designed for use direct at
the machine, where the focus is on a combination of ruggedness
and maximum reliability (the reliability of an embedded
platform), and the openness of a PC is also required (e.g.
module expansion and the connection of I/O devices such as
printers, keyboards, etc.).
Due to the minimal mounting depth, it can also be used in
confined spaces.
The PC can be used in production automation as well as in
process automation and can be mounted in control cabinets,
control desks, 19" cabinets/racks and in gantries.
A SIMATIC Panel PC is the ideal platform for PC based
Automation:
• PC based visualization on-site at the machine with
SIMATIC WinCC flexible
• PC based Control with SIMATIC WinAC RTX
• SIMATIC WinCC Web client for Web-based solutions with
WinCC/Web Navigator
• SIMATIC WinCC Standard Client
Siemens offers the complete set of building blocks of automation
components that are designed to interact perfectly.
Siemens ST 80 · 2009
3/5
3
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 477B embedded
■ Design
Expansion components
The Panel PC 477B embedded is a compact unit comprising an
operator control unit with an integrated computing unit.
3
Standard components of the computer unit:
• Rugged metal housing, resistant to vibrations and shocks,
with high electromagnetic compatibility.
• Processor:
- Intel Celeron M 1.0 GHz
• Main memory basic configuration:
- 1 GB (DDR2 SDRAM)
- Battery-buffered retentive memory 2 MB
• Compact Flash Drive (internal) with pre-installed Windows XP
embedded (Image) and optional software
• Graphics on board (VGA analog, 1280 x 1024)
• Interfaces:
- 2 x Ethernet on board (10/100/1000 Mbit/s)
- PROFIBUS DP/MPI on board, floating
- 5 x USB 2.0 port, 500 mA (1 x front)
- 1 x COM1 (RS232)
- 1 x DVI-I (for connecting a second display unit)
• Free slots for expansion:
- 1 x Compact Flash Slot (accessible from outside)
- 3 x PC/104 (over expansion frame)
• Power supply: 24 V DC
Components of the operator control unit:
The operator control units are available in the following versions:
12" Key
• 12.1" TFT color display, 800 x 600 pixels (SVGA)
• Membrane keyboard with international PC character set and
36 additional function keys and an integrated mouse
12" Touch
• 12.1" TFT color display, 800 x 600 pixels (SVGA)
• Resistive analog touch screen
15" Key
• 15.1" TFT color display, 1024 x 768 pixels (XGA)
• Membrane keyboard with international PC character set and
36 additional function keys and an integrated mouse
15" Touch
• 15.1" TFT color display, 1024 x 768 pixels (XGA)
• Resistive analog touch screen
19" Touch
• 19.1" TFT color display, 1280 x 1024 (SXGA)
• Resistive analog touch screen
The components are equipped with an USB 2.0 interface at the
front for connecting external I/O devices such as a mouse or
keyboard and fulfill the requirements of degree of protection
IP65 and NEMA 4. All computing units are also optionally
available with a front USB interface.
3/6
Siemens ST 80 · 2009
SIMATIC PC DiagMonitor
• PC diagnostics/alarm software for the early detection and
diagnosis of PC problems
• Comprehensive monitoring of temperature, watchdog
• Operating hours counter for preventive maintenance
• Integrated log functions, comprehensive text messages,
online help (English/German)
• Network-wide monitoring via SNMP and OPC interface
possible
SIMATIC PC/PG Image & Partition Creator
• Software tool for preventive data back-up of the contents of
bulk storage (CF cards, hard disks)
• High-speed, restoring of system and data partitions with bit
accuracy; application software and special installations are
also backed up
• Software tool for adaptation of hard disk partitioning
3.5" disk drive, USB
The USB diskette drive is provided for fast exchange of user
data, e.g., recipes, or of files. The drive must not be used as a
cyclic archiving drive. The front-panel installation and degree of
protection IP54 permit data exchange from the front without
opening the control cabinet door.
The device is connected via the USB interface of the Panel PC.
The power is also supplied over the USB interface. A USB cable
of 1 m length is included in the scope of supply. The diskette
drive complies with the USB 1.1 standard. 3.5" high density
diskettes can be used (1.44 MB).
Operation of the USB diskette drive with SIMATIC Panel PCs:
• Windows XP: Possible without separate driver
• The driver is included in the scope of supply of the operating
system
SIMATIC PC USB FlashDrive
• Mobile memory medium for SIMATIC PC/PG
• Fast data transfer (USB 2.0) and high memory capacity
• Ultra-compact and rugged
Industrial USB Hub 4
• Industry-standard USB 2.0 Hub, Front IP65
• Installation in control cabinet door or on DIN rail
• Inspection window and LEDs for each of the four interfaces
Note:
Further information can be found under "Expansion components"
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 477B embedded
■ Function
SIMATIC Panel PC 477B HMI, RTX and HMI/RTX
• Integrated, parameterizable monitoring functions (program
execution (watchdog)), temperature inside housing
• Expanded diagnostics/alarms over Ethernet, e-mail, SMS and
for direct infeed in SIMATIC software over OPC (optionally
through SIMATIC PC DiagMonitor)
■ Integration
Integrated interfaces:
• Ethernet
The integrated Ethernet interfaces (10/100/1000 Mbit/s) can
be used for IT communication and for exchanging data with
programmable controllers such as SIMATIC S7 (with the
"SOFTNET S7" software packages).
• PROFIBUS onboard
The floating PROFIBUS interface (12 Mbit/s) can be used for
connecting distributed field devices or for coupling to
SIMATIC S7 (with software packages "SOFTNET for
PROFIBUS").
• Additional slots
Three spare slots for PC/104-Plus modules are available as
well as five USB interfaces (Universal Serial Bus) and one
serial interface for connecting additional I/O devices.
HMI and HMI/RTX turnkey complete solutions (the software is
already preinstalled and configured) for visualization and
automation in combination with WinCC flexible and WinAC RTX.
• Quick start in automation solutions with Embedded
Automation
• SIMATIC WinCC flexible RT preinstalled and ready to switch
on (Panel PC 477B-HMI),
SIMATIC WinAC RTX preinstalled and ready to switch on
(Panel PC 477B-RTX),
SIMATIC WinCC flexible and SIMATIC WinAC RTX preinstalled
and ready to switch on (Panel PC 477B-HMI/RTX)
• PROFIBUS and Industrial Ethernet pre-configured for use in a
SIMATIC environment
• PROFINET and Industrial Ethernet pre-configured for use in a
SIMATIC environment
• Configuration and programming with SIMATIC WinCC flexible
ES and SIMATIC STEP 7 via Industrial Ethernet or PROFIBUS
• Flexibility of a PC-based automation environment
• Open for additional PC applications
• Expandable with PC/104+ – or PCI 104 cards (PCI interface)
• Connection option for USB devices, flat panel monitor or
screen
• Use of WinAC ODK with SIMATIC WinAC RTX
• Data retention for WinAC RTX without uninterruptible power
supply (UPS)
■ Technical specifications
Panel PC 477B embedded
General features
Panel PC 477B embedded
Interfaces
Processor
Intel Pentium M technology;
Intel Celeron M 1.0 GHz, Intel
Pentium M 1.4 GHz
Graphics interface
DVI-I can be used for additional
display unit (only VGA via
adapter); color depth 32 bits,
graphics memory up to 128 MB,
resolution as integral display in
each case
Memory type
DDR2-RAM
Main memory
1 GB, 2 GB
Free slots
3 x PC/104
(over spec. expansion frame)
Connection for keyboard/mouse
USB / USB
Serial interface
COM1: 1 x V.24 (RS232)
Operating system
Windows XP Embedded
PROFIBUS/MPI
Additional OS information
Language: EN/DE
SIMATIC Software
Optional with pre-installed bundle
software SIMATIC WinCC flexible
or WinCC flexible / WinAC RTX
Onboard, floating, max. 12 Mbit/s,
no plug-in card required, CP5611compatible, not upgradable
PROFINET
3 x RJ45, CP1616-compatible;
not upgradable
USB
1x on front, 4x on reverse,
USB 2.0 (500 mA)
Ethernet
Onboard, 2 x 10/100/1000 Mbit
(RJ45 with/without PROFIBUS),
1 x 10/100/1000 Mbit (RJ45 with
PROFIBUS), no plug-in card
required
Multimedia
No
Drives
Floppy drive
Optional via external USB floppy
drive
Optical drives
Possible as external drive via USB
Hard disk/mass storage
Compact Flash Drive with 2 GB
or 4 GB
Siemens ST 80 · 2009
3/7
3
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 477B embedded
■ Technical specifications (continued)
Panel PC 477B embedded
Supply voltage
Panel PC 477B embedded
Ambient conditions
Supply voltage
24 V DC
Vibration load during operation
Tested in accordance with DIN IEC
60068-2-6: 10 - 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/s² (1 g)
Shock loading during operation
Tested in accordance with DIN IEC
60068-2-7: 50 m/s² (5 g), 30 ms,
100 shocks
Relative air humidity
Tested in accordance with DIN IEC
60068-78, DIN IEC 68-2-30: 5% to
80% at 25 °C (no condensation)
Maximum permissible installation
angle +/-
30° over vertical
Ambient temperature during
operation
+5 °C to +50 °C in maximum
configuration; no fan
Monitoring functions
3
Temperature
Yes
Watchdog
Yes
Status LEDs
Yes (rear-side)
Front-side based on EN 60529
IP65 (front-side) based on
EN 60529 and NEMA4
Certifications & standards
Panel PC 477B
embedded
Approvals
CE, cULus(508)
EMC
CE, 55022A, EN 61000-6-4,
EN 61000-6-2
12" Touch
12" Key
15" Touch
15" Key
19" Touch
Front panel
12" TFT Touch
12" TFT Keys
15" TFT Touch
15" TFT Key
19" TFT Touch
Accessories
Touch cover foils
Keyboard insertable
strips
Touch cover foils
Keyboard insertable
strips
Touch cover foils
Resolution (W x H in
pixels)
800 x 600
800 x 600
1024 x 768
1024 x 768
1280 x 1024
MTBF of background
lighting (at 25 °C)
50 000 h at 24 h
continuous operation,
temperaturedependent
50 000 h at 24 h
continuous operation,
temperaturedependent
50 000 h at 24 h
continuous operation,
temperaturedependent
50 000 h at 24 h
continuous operation,
temperaturedependent
50 000 h at 24 h
continuous operation,
temperaturedependent
Heat loss in maximum
configuration
24 VDC: max. 70 W
24 VDC: max. 70 W
24 VDC: max. 70 W
24 VDC: max. 70 W
24 VDC: max. 90 W,
(contains 3 W per slot) (contains 3 W per slot) (contains 3 W per slot) (contains 3 W per slot) (contains 3 W per slot)
General features
Display
Type of operation
Function keys
No
36
No
36
No
Alphanumeric
keyboard
No
Yes
No
Yes
No
Touch screen
(analog/resistive)
Yes
No
Yes
No
Yes
Mouse on the front
No
Yes
No
Yes
No
Centralized
configuration
Yes
Yes
Yes
Yes
Yes
Decentralized
configuration
No
No
No
No
No
Mounting dimensions
of the centralized
configuration
(W x H x D, without
optical drive) in mm
368 x 290 x 75
450 x 290 x 75
450 x 290 x 75
450 x 321 x 75
450 x 380 x 88
Operator control unit
(W x H) in mm
400 x 310 (7 HU)
483 x 310 (19", 7 HU)
483 x 310 (19", 7 HU)
483 x 355 (19", 8 HU)
483 x 400 (19", 9 HU)
7.3 kg
7.7 kg
8.3 kg
8.7 kg
14.3 kg
Design
Dimensions
Weights
Panel PC in a centralized configuration
approx.
3/8
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 477B embedded
■ Ordering data
Order No.
Order No.
Versions for "Embedded Automation", TIA applications
Version for embedded PC applications
(preferred versions from stock)
SIMATIC Panel PC 477B emb
D
6ES7 676 - 7 A A 0 0 - 0 7 A 0
Celeron 900 MHz processor,
1 GB RAM, without fieldbus
interface1), Windows XP
embedded operating system preinstalled
• 12" TFT Touch
1
• 15" TFT Touch
3
6ES7 676- 7 B A 0 0 - 0 7 7 0
• CompactFlash 2 GB
C
• CompactFlash 4 GB
D
• With Windows XP embedded
operating system preinstalled
3
Frontpanels
Mass storage
A
• 12" TFT Touch
1
• 12" TFT Key
2
• 15" TFT Touch
3
• 15" TFT Key
4
• 19" TFT Touch
6
Mass storage
D) Subject to export regulations: AL: N and ECCN: 5D992B1
• CompactFlash 2 GB
C
• CompactFlash 4 GB
D
Software Pakete
Order No.
Ready-to-use Panel PC 477B as
a WinCC Standard Client
WinCC V7.0 is already installed
and set up on the 4 GB compact
flash card as a standard client.
The Panel PC 477B has a 24 V
DC power supply and has 2x
Ethernet 1Gbit/s, 4x USB 2.0,
1x COM1 (RS232).
Available solutions:
• With Windows XP embedded
operating system (EN/DE)
preinstalled
A
• With operating system and RTX
(DP), Windows XP embedded
preinstalled, WinAC RTX preinstalled and configured for
PROFIBUS
B
• With operating system and HMI,
Windows XP embedded preinstalled, WinCC flexible RT (incl.
archives/recipes) preinstalled
• 15" Touch,
Celeron 1.0 GHz processor with
1 GB of main memory
6ES7 676-3DA20-0DS0
• 15" Touch,
Pentium M 1.4 GHz processor
with 2 GB of main memory
6ES7 676-3GA30-0DS0
• 19" Touch,
Celeron 1.0 GHz processor with
1 GB of main memory
6ES7 676-6DA20-0DS0
• 19" Touch,
Pentium M 1.4 GHz processor
with 2 GB of main memory
6ES7 676-6GA30-0DS0
2)
D
Celeron M 1.0 GHz processor,
main memory 1 GB DDR2
SDRAM,
power supply 24 V DC, 2x
Ethernet 1 Gbit,
PROFIBUS DP interface
Front panels
■ Ordering data
SIMATIC Panel PC 477B emb
Not retrofittable since it is a placement option
- Number of tags 128 PT
C
- Number of tags 512 PT
D
- Number of tags 2048 PT
E
• With operating system and
HMI/RTX (DP)
Windows XP embedded preinstalled, WinCC flexible RT (incl.
Archives/Recipes) preinstalled,
WinAC RTX preinstalled and
configured for PROFIBUS
- Number of tags 128 PT
F
- Number of tags 512 PT
G
- Number of tags 2048 PT
H
D) Subject to export regulations: AL: N and ECCN: 5D992B1
Siemens ST 80 · 2009
3/9
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 477B embedded
■ Ordering data
Order No.
Order No.
Further Panel PCs as build to order versions
Further Panel PCs as build to order versions
(max. delivery time 15 working days)
(continued)
SIMATIC Panel PC
477B embedded
D
6AV7 85 7 - 0 A 7 7 7 - 7 7 A 0
24 V DC power supply
Front panels
3
• 12" TFT Touch
1
• 12" TFT Key
2
• 15" TFT Touch
3
• 15" TFT Key
4
• 19" TFT Touch
6
SIMATIC Panel PC
477B embedded
(continued)
D
6AV7 85 7 - 0 A 7 7 7 - 7 7 A 0
Software packages
(continued)
With operating system Windows
XP embedded (EN/DE)
B
With operating system and HMI,
Windows XP embedded preinstalled, WinCC flexible RT (incl.
archives/recipes) preinstalled
Processor
• Number of tags 128 PT
D
• Celeron M 1.0 GHz
D
• Number of tags 512 PT
E
• Celeron M 1.0 GHz with
PROFIBUS DB12
E
• Number of tags 2048 PT
F
• Celeron M 1.0 GHz with
PROFINET
F
• Pentium M 1.4 GHz
G
• Pentium M 1.4 GHz with
PROFIBUS DB12
H
• WinAC RTX (DP), configured for
PROFIBUS
C
• Pentium M 1.4 GHz with
PROFINET
J
• WinAC RTX (PN), configured for
PROFINET
K
With operating system and RTX
Windows XP embedded preinstalled, WinAC RTX preinstalled
and configured
With operating system and
HMI/RTX (DP)
Windows XP embedded preinstalled, WinCC flexible RT (incl.
Archives/Recipes) preinstalled,
WinAC RTX preinstalled and
configured for PROFIBUS
Main memory
• 1 GB DDR2 SDRAM
2
• 2 GB DDR2 SDRAM
3
Second CompactFlash slot
(externally accessible)
- Not fitted
0
• Number of tags 128 PT
G
- fitted with CF card 2 GB
3
• Number of tags 512 PT
H
4
• Number of tags 2048 PT
J
- with CF card 4 GB, fitted
• With CF card 2 GB
3
With operating system and
HMI/RTX (PN)
Windows XP embedded preinstalled, WinCC flexible RT (incl.
Archives/Recipes) preinstalled,
WinAC RTX preinstalled and
configured for PROFINET
• With CF card 4 GB
4
• Number of tags 128 PT
L
• Number of tags 512 PT
M
• Number of tags 2048 PT
N
Software packages
With
Windows XP embedded
operating system (EN/DE) preinstalled
D) Subject to export regulations: AL: N and ECCN: 5D992B1
Please note:
The scope of supply of the Panel PC 477B mainly comprises the
Panel PC and a software pack that contains the CompactFlash
card with preinstalled and configured software as well as all the
necessary license keys. Only after the CompactFlash card has
been inserted in the (internal) slot provided is the unit ready for
switching on.
Note:
Further embedded versions based on Microbox PC are listed
under SIMATIC PC based Control.
3/10
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 477B embedded
■ Ordering data
Order No.
Expansion components
6ES7 648-6CA04-0YX0
SIMATIC PC/PG DiagMonitor
V4.0
A
6ES7 648-6BA02-1YX0
Software tool for data backup for
SIMATIC PCs, incl. manual, on
CD-ROM (Eng/Ger/Fr/Sp/It)
SIMATIC PC Partition Creator
V2.1
A
6ES7 648-6AA02-1YX0
• for 12" Touch
6AV7 671-2BA00-0AA0
• for 15" Touch
6AV7 671-4BA00-0AA0
• for 19" Touch
6AV7 671-1CE00-0AA0
Labeling foil for Panel
PCs 477/577/677/877
6AV7 672-0DA00-0AA0
3
For labeling softkeys and function
keys, blank, supplied in sets of 10
Touch pen
Software tool for hard-disk partitioning for SIMATIC PCs, incl.
manual, on CD-ROM
(Eng/Ger/Fr/Sp/It)
SIMATIC PC USB FlashDrive
Cover foil for Panel
PCs 477/577/677/877
For protecting the touch screen
against dirt/scratches
Software tool for monitoring
SIMATIC PCs,
incl. manual, on CD-ROM
(German/English)
SIMATIC PC Image Creator
V2.1
Order No.
Accessories
A
6AV7 672-1JB00-0AA0
Undetachable pen for operation
of the touch devices, mounting of
the support on the control cabinet
A
6ES7 648-0DC40-0AA0
A
6FC5 235-0AA05-1AA2
A
6AV6 671-3AH00-0AX0
2 GB, USB 2.0, metal enclosure,
bootable
3.5" disk drive, USB
With 1 m connecting cable
Industrial USB Hub 4
4 x USB 2.0, IP65 for control
cabinet door or DIN rail
Compact Flash Card
• 2 GB
A
6ES7 648-2BF01-0XF0
• 4 GB
A
6ES7 648-2BF01-0XG0
Expansion kit PC/104
A
6AG4 070-0BA00-0XA0
For integration of PC/104 modules
(packing unit contains 6
expansion frames)
A) Subject to export regulations: AL: N and ECCN: EAR99H
Siemens ST 80 · 2009
3/11
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 477B embedded
■ Dimensions
W+1 (cutout)
H
H+1 (cutout)
3
W
Touch panels
12"
15"
19"
Key panels
12"
15"
Installation cutouts
W
H
400
483
483
310
310
400
W
H
483
483
310
355
Touch panels
W+1
H+1
12"
15"
19"
368
450
450
290
290
380
Key panels
W+1
H+1
12"
15"
450
450
290
321 *
* In addition: two 25 x 5 mm recesses on the top side
for keyboard slide-in label channels
G_ST80_XX_00290Y
Front dimensions
Operating unit and complete unit
■ More information
G
You will find more information on the Internet at:
http://www.siemens.com/panel-pc
T
Note:
K
K
T
Touch panels
12"
15"
19"
289
289
307
3
3
11
75
75
98
Key panels
12"
15"
289
324
3
3
75
75
All dimensions without screw protrusions
Installation cutout
3/12
Siemens ST 80 · 2009
G_ST80_XX_00283
G
Operator panels PC 477B
Do you need a specific modification or expansion to the
products described here? Then refer to "Customer-specific
products". Information is available here about additional,
generally available sector products as well as the possibilities
for customer-specific modification and adaptation.
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 577B
■ Overview
■ Design
The Panel PC 577B is equipped as follows:
PC with standard industrial capability, full PC openness and
attractive price
• Rugged design for industrial use
• Touch screen operator units with 12", 15" and 19" TFT display
• Expandable using 2 PCI slots
• All versions available from stock
■ Benefits
• High degree of operational safety and minimization of
standstill times – even under mechanical stress
• Highly expandable by the customer thanks to diverse
interfaces (PCI, CompactFlash, GBit Ethernet, and others)
• All versions available at short notice and low cost direct from
stock
■ Application
The SIMATIC Panel PC 577B is used in manufacturing
automation and process automation. The device has been
designed for installation in control cabinets and consoles,
19" cabinets/racks, and swivel arms (booms).
Thanks to its full PC openness and the powerful Celeron M
processor, it can be used for a host of different applications.
Computing unit
• Rugged metal housing for industrial use
• Processor: Intel Celeron M 440/1.86 GHz with Mobile Intel
945G chipset
• Main memory configuration: 1 GB
• Hard disk ≥ 80 GB (3.5" SATA) with vibration-absorbent hard
disk holder guarantees reliable operation even under
conditions of high mechanical stress
• Graphics onboard
• Interfaces:
- 2 x 10/100/1000 Ethernet
- 4 x USB 2.0 port, (500 mA) + 1 x front interface
- 1 x serial V.24 (9-pin)
• Free slots for expansion:
- 2 x PCI (slots with card retainer)
- 1 x slot for Compact Flash Card (externally accessible)
• Power supply: 100/240 VAC, (autorange), 50/60 Hz
• DVD ± RW ± R combo drive
Operating unit
Operating units are available in the following sizes/resolutions:
• 12" Touch: 12.1" TFT color display, 800 x 600 pixels (SVGA)
• 15" Touch: 15.1" TFT color display, 1024 x 768 pixels (XGA)
• 19" Touch: 19.1" TFT color display, 1280 x 1024 pixels (SXGA)
The operating units have the following functionality:
• Analog-resistive touchscreen
• Degree of protection IP65 and NEMA 4
• USB 2.0 interface on the front for connecting external I/O
devices such as mouse or keyboard
Expansion components (accessories)
SIMATIC PC DiagMonitor
• PC diagnostics/alarm software for the early detection and
diagnosis of PC problems
SIMATIC PC/PG Image & Partition Creator
• Software tool for preventive data backup of hard disk contents
SIMATIC PC USB FlashDrive
• Mobile memory medium for SIMATIC PC/PG
Industrial USB Hub 4
• Industry-standard USB 2.0 Hub, Front IP65
Siemens ST 80 · 2009
3/13
3
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 577B
■ Function
■ Integration
• Integral, parameterizable monitoring functions: Program
execution (watchdog), internal temperature of housing, fan
speed
• Expanded diagnostics/messages via Ethernet, e-mail, SMS
and for direct transfer to SIMATIC software via OPC (optionally
via SIMATIC PC DiagMonitor)
3
Integral interfaces
• PCI
Two free PCI slots are available for expansion with plug-in
cards.
• Ethernet
The integral Ethernet interfaces (10/100/1000 Mbit/s) can be
used for IT communication and for exchanging data with
programmable controllers such as SIMATIC S7 (with the
"SOFTNET S7" software packages).
• Further interfaces
One Compact Flash Card slot, 5 USB 2.0 interfaces (Universal
Serial Bus), as well as one serial interface are available for
further I/O devices.
■ Technical specifications
Panel PC 577B
Processor
Panel PC 577B
Voltage supply
Processor
Intel Celeron M 440, 1.86 GHz,
533 MHz FSB, 1MB SLC
Memory
Voltage
AC 100 V / 240 V (autorange)
50/60 Hz
Monitoring functions
Type of storage
Main memory
1 GB
Slots
• Free slots
2 x PCI (slots with board retainer),
1 x slot for Compact Flash Card
(externally accessible)
Operating systems
Temperature
Yes
Watchdog
Yes
Status LEDs
No
Degree of protection
Front to EN 60529
IP65 (on front) to EN 60529 and
NEMA4
Ambient conditions
Operating system
Windows XP Prof. optional: without
operating system
Vibration load in operation
Aditional operating system
Multi Language: GER, EN, IT, FR,
SP, KOR, CHN (Traditional), CHN
(Simplified), JPN
tested to IEC 68-2-6: 10 to 58 Hz:
0.075 mm, 58 to 200 Hz: 9.8 m/s2
(0.25 g)
Shock loading in operation
tested to IEC 68-2-29: 50 m/s2
(1 g), 30 ms, 100 shocks
Relative humidity
Tested to DIN IEC 68-2-3, DIN IEC
68-2-30, DIN IEC 68-2-56: 5% to
80% at 25 °C (no condensation)
20°
Drives
Diskette drive
optional: via external USB floppy
disk drive
Optical drives
DVD ± R ± RW combi drive; on
rear, can be operated from side
Maximum permissible installation
angle +/-
Hard disk/Mass storage
3.5" SATA hard disk ≥ 80 GB,
vibration-resistant mounting
Temperature
DVI-I usable for additional display
unit (VGA via adapter); color depth
32 bits, 8 to 128 MB Shared
Memory
Certifications & Standards
Interfaces
• Graphics interface
• Ambient temperature in operation In full configuration:
+5 °C to +45 °C1)
Approval
CE, CULus (508)
EMC
CE, EN 55011, EN 61000-6-4,
EN 61000-6-2
• Connection for keyboard/mouse
USB / USB
• Serial interface
COM1: 1 x V.24 (RS232)
Expansion components
PROFIBUS/MPI
expandable with plug-in cards
Expansion components
USB
1 x at front, 4 x at rear,
USB 2.0 (500 mA)
1)
max. 50 °C in installation space, if at front 40 °C max.
3/14
Siemens ST 80 · 2009
Uninterruptible power supply
(UPS), SIMATIC NET communication units, DiagMonitor,
Image&Partition Creator
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 577B
■ Technical specifications (continued)
Panel PC 577B
12" Touch
15" Touch
19" Touch
Front panel
12" TFT Touch
15" TFT Touch
19" TFT touch display
Accessory components
Touch protective foil
Touch protective foil
Touch cover foils,
fixing elements for screw mounting
at the front
General features
Display
Screen diagonal
12"
15"
19"
Resolution (W x H in pixel)
800 x 600
1024 x 768
1280 x 1024
MTBF backlighting (at 25 °C)
50 000 h in 24 h permanent
operation, temperature-dependent
50 000 h in 24 h permanent
operation, temperature-dependent
50 000 h in 24 h permanent
operation, temperature-dependent
Power loss in full configuration
Max. 140 W
(17,5 W included per slot)
Max. 140 W
(17.5 W included per slot)
Max. 163 W
(17.5 W included per slot)
Operating mode
Function keys
No
No
No
alphanumeric keyboard
No
No
No
Touchscreen (analog/resistive)
Yes
Yes
Yes
Mouse, at front
No
No
No
central design
Yes
Yes
Yes
distributed design
No
No
No
Mounting cutout/Device depth
(W x H / D) in mm
368 x 290 / 144 (incl. optical drive)
450 x 290 / 142 (incl. optical drive)
450 x 380 / 151 (incl. optical drive)
Install. dimensions, centralized
design (W x H / D without optical
drive) in mm
368 x 290 / 123
450 x 290 / 121
450 x 380 / 130
additional mounting depth (optical
drive)
21 mm
21 mm
21 mm
Operator panel (W x H) in mm
400 x 310 (7 HU)
483 x 310 (19", 7 HU)
483 x 400 (19", 9 HU)
14 kg
17 kg
Design
Dimensions
Weights
Panel PC in central design, approx. 13 kg
Siemens ST 80 · 2009
3/15
3
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 577B
■ Ordering data
Order No.
Order No.
A)
All versions available from stock
6AV7 83 7 - 0 B A 1 0 - 1 C 7 0
SIMATIC Panel PC 577B
3
Accessories
Touch front panel with front USB
port
• 100/240 V AC, with power cable
for Europe and USA
• Intel Celeron M 440 / 1.86 GHz
(533 MHz FSB, 1 MB SLC)
• Free slots: 2 x PCI
• Main memory: 1 GB DDR2
• Hard disk drive 80GB SATA 3.5“
• DVD ± RW ± R combo drive
Cover foil for Panel PCs,
set of 10
For protecting the touch screen
against dirt/scratches
• for 12" Touch
6AV7 671-2BA00-0AA0
• for 15" Touch
6AV7 671-4BA00-0AA0
• for 19" Touch
6AV7 672-1CE00-0AA0
Memory expansion
Front panels
• 1 GB DDR2
A
6ES7 648-2AG40-0HA0
• 2 GB DDR2
A
6ES7 648-2AG50-0HA0
Non-heating device cover for
SIMATIC Box PC and Panel PC
• 12" TFT Touch
0
• 15" TFT Touch
2
SIMATIC PC power cable, 230 V
AC, angled, 3 m, for:
• 19" TFT Touch
5
• Europe: D/F/NL/E/B/A/S/FIN 1)
6ES7 900-1AA00-0XA0
Operating system
• United Kingdom
6ES7 900-1BA00-0XA0
• Without operating system
K
A
• Switzerland
6ES7 900-1CA00-0XA0
• Windows XP Professional
Multi-Language1)
D
C
• USA
6ES7 900-1DA00-0XA0
• Italy
6ES7 900-1EA00-0XA0
• China
Touch pen
6ES7 900-1FA00-0XA0
A
6AV7 672-1JB00-0AA0
Undetachable pen for operation
of the touch devices, mounting of
the support on the control cabinet
Expansion components
6ES7 648-6CA04-0YX0
SIMATIC PC/PG DiagMonitor
V4.0
Software tool for monitoring
SIMATIC PCs, incl. manual, on
CD-ROM (German/English)
SIMATIC PC Image Creator
V2.1
A
6ES7 648-6BA02-1YX0
A
6ES7 648-6AA02-1YX0
A
6ES7 648-0DC40-0AA0
A
6FC5 235-0AA05-1AA2
A
6AV6 671-3AH00-0AX0
Software tool for data backup for
SIMATIC PCs, incl. manual, on
CD-ROM (Eng/Ger/Fr/Sp/It)
SIMATIC PC Partition Creator
V2.1
Software tool for hard-disk partitioning for SIMATIC PCs, incl.
manual, on CD-ROM
(Eng/Ger/Fr/Sp/It)
SIMATIC PC USB FlashDrive
2 GB, USB 2.0; metal enclosure,
bootable
3.5" disk drive, USB
With 1 m connecting cable
Industrial USB Hub 4
4 x USB 2.0 interfaces, IP65 for
control cabinet door or DIN rail
assembly
Communication components
PCI interface card
With COM1, COM2 and LPT
interfaces
A) Subject to export regulations: AL: N and ECCN: EAR99H
D) Subject to export regulations: AL: N and ECCN: 5D992B1
K) Subject to export regulations: AL: N and ECCN: 4A994B1
1)
Multi-language means: D/E/F/I/SP/CHIN traditional/CHIN
simplified/Korean/Japanese
3/16
Siemens ST 80 · 2009
6ES7 648-2CA10-0AA0
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 577B
■ Dimensions
3
H
G
M
K
J
Touch panels
12"
15"
19"
L
G
H
J
K
L
M
N
289
289
378
271
271
271
141
138
147
11
11
11
53
24
18
369
367
376
71
42
36
N
G_ST80_XX_00317
Operator panels PC 577B
All dimensions without screw protrusions
Control unit and complete device
W+1 (cutout)
H
H+1 (cutout)
W
Touch panels
12"
15"
17“
19"
Installation cutouts
W
H
400
483
483
483
310
310
400
400
Touch panels
W+1
H+1
12"
15“
17"
19"
368
450
450
450
290
290
380
380
G_ST80_XX_00239
Front dimensions
Siemens ST 80 · 2009
3/17
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Overview
■ Benefits
3
PC platform with high degree of industrial compatibility for
demanding tasks in the area of PC-based automation.
Rugged construction:
The PC is resistant to the harshest mechanical stress and is
reliable in operation.
• Compact design
• High degree of investment protection
• Fast integration capability
• Front panel versions:
- 12", 15", 17" and 19" TFT Touch
- 12" and 15" TFT Key
- 15" TFT Touch, stainless steel/INOX
• The operator control unit and computing unit can be placed
30 m apart (optional).
• Excellent industrial compatibility due to rugged construction,
even when subjected to extreme vibration and shock
• High level of investment security thanks to assured spare
parts availability of the components (for 5 years following the
end of active marketing)
• Excellent continuity of components for machine concepts with
a long service life without any new engineering costs
• Savings in time and costs due to service-friendly equipment
construction:
- Operator control unit and computer unit can be simply
hinged open for fast replacement of components or for future
expansion
- USB 2.0 interfaces on the front and rear for quick and easy
connection of additional hardware components
• High degree of industrial functionality thanks to integrated
PROFIBUS DP/MPI or PROFINET interfaces (CP1616compatible) and 2 GB Ethernet interfaces
• Operational reliability
Using the optional direct control key module, the process can
be operated without delay over PROFIBUS DP independently
of the operating system
• 2 x ≥ 80 GB SATA hard disk system (configured as a single
disk system or RAID1)
• Reduction in standstill times thanks to high system availability
• Efficient self-diagnostics (SIMATIC PC DiagMonitor):
- Solutions for preventative data security
• Integral component of Totally Integrated Automation (TIA):
- Enhanced productivity, reduction of engineering costs,
reduction of lifecycle costs
- Spatially separated configuration of computer and operator
control unit possible with the Remote Kit (up to 30 m,
optionally available as accessories)
■ Application
SIMATIC Panel PC 677B is designed for use directly at the
machine. Due to the minimal mounting depth of only 105/
130 mm, it can also be used in confined spaces.
The PC can be used in production automation as well as in
process automation and can be mounted in control cabinets,
control desks, 19" cabinets/racks and in gantries.
The Dual Core CPUs with Intel Core 2 Duo technology support
simultaneously high performance control and visualization.
With PCIe (x4), the new PCI express (PCIe) cards (x1 and x4) are
also supported.
The integrated NV-RAM is supported from WinAC RTX 2005 SP2
and with DC power supply.
A SIMATIC Panel PC is the ideal platform for PC based
Automation:
• PC based visualization on site at the machine with SIMATIC
WinCC flexible
• Complex solutions with SIMATIC WinCC process visualization
• PC-based Control with SIMATIC WinAC Software PLC or with
SIMATIC WinAC Slot PLC
Siemens offers the complete set of building blocks of automation
components that are designed to interact perfectly.
The SIMATIC Panel PCs can be ordered in combination with
WinCC flexible or WinCC as SIMATIC HMI packages at a lower
price (see SIMATIC HMI complete systems).
3/18
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Design
The Panel PC 677B comprises a computer unit and an operator
control unit.
Components of the computer unit:
• Rugged metal housing, resistant to vibrations and shocks,
with high electromagnetic compatibility.
• Processor:
- Mobile Intel 945G chip set
- Intel Celeron M 440/1.86 GHz or
- Intel Core 2 Duo T5500 / Dual Core, 1.66 GHz or
- Intel Core 2 Duo T7400 / Dual Core, 2.16 GHz
• Main memory basic configuration: 1 GB
• 3.5" SATA hard disk: ≥ 80 GB;
the special vibration-absorbing hard disk ensures reliable
operation even under extreme mechanical stress
• Graphics on board
• Interfaces:
- 2 x 10/100/1000 Ethernet
- PROFIBUS DP/MPI on board, floating
- PROFINET (IRT-capable), 3-port, switching-enabled,
CP1616-compatible
- 4 x USB 2.0 connection
- 1 x serial V.24 (9-pin)
• Retentive memory:
- 512 KB NV-RAM for Win AC RTX without UPS (DC versions)
• Free slots for expansion:
- 2 x PCI (slots with card retainer)
- 1 x slot for Compact Flash Card
• Power supply: 110 V / 230 V AC (autorange), 50/60 Hz or
24 V DC
Optional additional components:
• Main memory expansion to 2, 3 or 4 GB
• SATA hard disk ≥ 160 GB
• Dual hard disk module 2 x ≥ 80 GB SATA preconfigured as
single disk configuration or RAID1
• Internal CF card slot (empty, instead of hard disk and optical
drive; only with Windows XP embedded operating system)
• DVD ± RW ± R combo drive
• 1x PCIe x4 / 1x PCI instead of 2 x PCI slots
(with card retainers)
• Direct control key module (for devices with key front)
Components of the operator control unit:
The operator control units are available in the following versions:
12" Key
• 12.1" TFT color display, 800 x 600 pixels (SVGA)
• Membrane keyboard with international PC character set and
36 additional function keys with LED and an integrated mouse
12" Touch
• 12.1" TFT color display, 800 x 600 pixels (SVGA)
• Resistive analog touch screen
15" Key
• 15.1" TFT color display, 1024 x 768 pixels (XGA)
• Membrane keyboard with international PC character set and
36 additional function keys with LED and an integrated mouse
15" Touch
• 15.1" TFT color display, 1024 x 768 pixels (XGA)
• Resistive analog touch screen
15" Touch, stainless steel/INOX
• 15.1" TFT color display, 1024 x 768 (XGA)
• Resistive analog touch screen
• Stainless steel front, designed for use in the food and
beverages industry
• Developed on the basis of DIN EN 1672-2
• Polished surface (stainless steel 1.4301, line pattern, grainsize 240)
• IP66k on front
• Without USB front interface
• Shatter-protection for the display
• Optimized frame surface to allow liquids to run off
• Minimized grooves and gaps
• Decorative foil tested against chemicals in accordance with
DIN 42115, Part 2
• Mounting with clamping frame only. Sealing material food-safe
(EDPM, in accordance with FDA 21 CFR 177.2006)
• Prepared for EHEDG certification for the entire machine
17" Touch
• 17,1" TFT color display, 1280 x 1024 pixels (SXGA)
• Resistive analog touch screen
• Installation compatible to 19" touch
19" Touch
• 19.1" TFT color display, 1280 x 1024 pixels (SXGA)
• Resistive analog touch screen
The operator control units feature a USB 2.0 port on the front for
connecting external peripheral devices, such as a mouse or
keyboard. They fulfill the requirements of degree of protection
IP65 and NEMA 4. All operator control units are also available
without a USB port on the front.
The computer unit is connected via a connecting cable attached
at the rear of the operator control unit.
Siemens ST 80 · 2009
3/19
3
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Design (continued)
Expansion components
3
SIMATIC PC DiagMonitor
• PC diagnostics/alarm software for the early detection and
diagnosis of PC problems
• Comprehensive monitoring of temperature, fan, hard disks
(SMART), watchdog
• Operating hours counter for preventive maintenance
• Integrated log functions, comprehensive text messages,
online help (English/German)
• Network-wide monitoring via SNMP and OPC interface
possible
• Integrated Web server for monitoring over the network using a
Web browser
SIMATIC PC/PG Image & Partition Creator
• Software tool for preventive data back-up of the contents of
the hard disks
• High-speed, restoring of system and data partitions with bit
accuracy; application software and special installations are
also backed up
• Software tool for adaptation of hard disk partitioning
SIMATIC PC USB FlashDrive
• Mobile memory medium for SIMATIC PC/PG
• Fast data transfer (USB 2.0) and high memory capacity
• Ultra-compact and rugged
3.5" disk drive, USB
The USB disk drive is provided for the high-speed transfer of
user data, such as recipes, or files. The drive must not be used
as a cyclic archiving drive. The front-panel installation and
degree of protection IP54 permit data exchange from the front
without opening the control cabinet door.
The device is connected via the USB interface of the Panel PC.
The power is also supplied over the USB interface. A USB cable
of 1 m length is included in the scope of supply. The diskette
drive complies with the USB 1.1 standard. 3.5" high density
diskettes can be used (1.44 MB).
SIMATIC Panel PC Remote Kit
• Spatially separated configuration of computer and operator
control unit
• At a maximum distance of up to 30 m
• Pure hardware solution, no need to install additional software
• Maintaining the Panel PC front functionality
• Additional USB interface on the rear
• Centralized and distributed configuration with only one basic
unit
• Can be retrofitted
Industrial USB Hub 4
USB I/O can be connected and operated without opening the
control cabinet door using the Industrial Hub 4.
• Industry-standard USB 2.0 Hub, Front IP65
• Mounting in control cabinet door or on DIN rail
• Inspection window and LEDs for each of the four interfaces
Note:
For further information, see "Expansion components"
3/20
Siemens ST 80 · 2009
■ Function
• Integrated, parameterizable monitoring functions (program
execution (watchdog), temperature inside housing, fan
speed)
• Expanded diagnostics/alarms over Ethernet, e-mail, SMS and
for direct infeed in SIMATIC software over OPC (optionally
through SIMATIC PC DiagMonitor)
• RAID1 for automatic data mirroring on two SATA hard disks
■ Integration
Integrated interfaces
• Ethernet
The integrated Ethernet interfaces (10/100/1000 Mbit/s) can
be used for IT communication and for exchanging data with
programmable controllers such as SIMATIC S7 (with the
"SOFTNET S7" software packages).
• PROFIBUS
The floating PROFIBUS interface (12 Mbit/s) can be used for
connecting distributed field devices or for coupling to
SIMATIC S7 (with software package "SOFTNET for
PROFIBUS").
• PROFINET
The three (IRT-capable) PROFINET ports can be used to
connect distributed I/O, SIMATIC S7 and drives. The
switching-capable ports of the CP1616-compatible
PROFINET option support linear and tree topologies (WinAC
RTX Version 2008 and higher). Alternatively, the interface can
be used as a standard Windows interface.
• Further interfaces
For connecting additional I/O devices, 2 spare slots are
available for PCI modules or alternatively 1 x PCI and 1 x PCIe
x4 modules, as well as a Compact Flash Card interface, 5 USB
2.0 interfaces (Universal Serial Bus) and one serial interface.
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Technical specifications
Panel PC 677B (incl. INOX)
Supply voltage
Supply voltage
Panel PC 677B (incl. INOX)
Interfaces
100 VAC / 240 VAC (autorange)
50/60 Hz; option 24 V DC
Graphics interface
DVI-I usable for additional display
unit (VGA via adapter); color depth
32 bits, 8 to 128 MB Shared
Memory
Intel Core 2 Duo technology; Intel
Celeron M 440, 1.86 GHz, 533
MHz FSB, 1 MB SLC; Core 2 Duo
T5500, 1.66 GHz, 667 MHz FSB,
2 MB SLC; Core 2 Duo T7400, 2.16
GHz, 667 MHz FSB, 4 MB SLC
Connection for keyboard/mouse
USB / USB
Serial interface
COM1: 1 x V.24 (RS232)
PROFIBUS/MPI
1
USB
1 x at front, 4 x at rear,
USB 2.0 (500 mA)
2x PCI or 1xPCI & 1x PCIe x4 (slots
with card retainer), 1x slot for
Compact Flash Card
Ethernet
onboard, 2 x 10/100/1000 Mbit/s,
RJ45, no plug-in card necessary
Processor
Processor
Slots
Free slots
Monitoring functions
Memory
Temperature
yes
Type of storage
Watchdog
yes
Status LEDs
yes
Main memory
1 GB to 4 GB
Operating systems
Operating system
Additional information
Degree of protection
Windows Vista Ultimate (Multi
Language), Windows 2000 Prof.
(Multi Language), Windows XP
Prof. (Multi Language), Windows
XP embedded (English) on CF
Card, optionn. without operating
system
Front to EN 60529
Vibration load in operation
Tested to DIN IEC 68-2-6:
10 to 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/m2 (1 g)
Multi Language: GER, EN, IT, FR,
SP, KOR1), CHN (Traditional)1),
CHN (Simplified)1), JPN1) - not with
XPe
Shock loading in operation
Tested to DIN IEC 68-2-29: 50
m/m2 (5 g), 30 ms, 100 shocks
Relative humidity
Tested to DIN IEC 68-2-3, DIN IEC
68-2-30, DIN IEC 68-2-56: 5% to
80% at 25 °C (no condensation)
Optionally in package with
SIMATIC WinCC or WinCC flexible
maximum permissible installation
angle +/-
20°
Temperature
Drives
Diskette drive
optional: via external USB floppy
disk drive
Optical drives
optional: DVD ± R ± RW combi
drive; on rear, can be operated
from side
Hard disk/Mass storage
3.5" SATA hard disk ≥ 80 GB,
optional ≥ 160 GB, optional: 2 x
2.5" SATA hard disk module (≥ 80
GB), RAID 1 controller onboard; all
drives are vibration-damped,
2nd CF Card slot as option
1)
IP65 (on front) to EN60529
and NEMA4
Ambient conditions
Configuration
SIMATIC Software
3
Ambient temperature in operation
Full configuration:
12"/15": +5 ... 50 °C,
17"/19": +5 ... 45 °C or
+5 ... 50 °C in installation space, if
front max. 40°C
Certifications & Standards
Approval
CE, CULus (508)
EMC
CE, EN 55011, EN 61000-6-4,
EN 61000-6-2
not for Vista MUI
Siemens ST 80 · 2009
3/21
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Technical specifications (continued)
Panel PC 677B
12" Touch
12" Key
15" Touch
15" Key
17" Touch
19" Touch
Front panel
12" TFT Touch
12" TFT Key
15" TFT Touch
15" TFT Key
17" TFT touch
19" TFT touch
Accessory
components
Touch protective
foil, remote kit
Slide-in keyboard
labels, direct key
module, remote kit
Touch protective foil Slide-in keyboard
(not for Inox front), labels, direct key
remote kit
module, remote kit
Touch cover foils,
remote kit, fixing
elements for screw
mounting at the
front
Touch cover foils,
remote kit, fixing
elements for screw
mounting at the
front
General features
3
Display
Screen diagonal
12"
12"
15"
15"
17"
19"
Resolution (W x H
in pixel)
800 x 600
800 x 600
1024 x 768
1024 x 768
1280 x 1024
1280 x 024
MTBF backlighting
(at 25 °C)
50 000 h in 24 h
permanent
operation, temperature-dependent
50 000 h in 24 h
permanent
operation, temperature-dependent
50 000 h in 24 h
permanent
operation, temperature-dependent
50 000 h in 24 h
permanent
operation, temperature-dependent
50 000 h in 24 h
permanent
operation, temperature-dependent
50 000 h in 24 h
permanent
operation, temperature-dependent
Expansion
components
Uninterruptible
power supply
(UPS), SIMATIC
NET communication modules
Uninterruptible
power supply
(UPS), SIMATIC
NET communication modules
Uninterruptible
power supply
(UPS), SIMATIC
NET communication modules
Uninterruptible
power supply
(UPS), SIMATIC
NET communication modules
Uninterruptible
power supply
(UPS), SIMATIC
NET communication modules,
DiagMonitor,
ImagePartition
Creator
Uninterruptible
power supply
(UPS), SIMATIC
NET communication modules,
DiagMonitor,
ImagePartition
Creator
Power loss in full
configuration
max. 140 W (15 W
included per slot)
max. 140 W (15 W
included per slot)
max. 140 W (15 W
included per slot)
max. 140 W (15 W
included per slot)
max. 160 W (15 W
included per slot)
max. 163 W (15 W
included per slot)
No
36 with LEDs
No
36 with LEDs
No
No
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
yes
No
yes
Operating mode
Function keys
Alphanumeric
keyboard
Touchscreen
(analog/resistive)
Yes
Mouse, at front
Design
Central design
Yes
Yes
Yes
Yes
Yes
Yes
Distributed design
Yes
Yes; by means of
remote kit
Yes; by means of
remote kit
Yes; by means of
remote kit
Yes; by means of
remote kit
Yes; by means of
remote kit
368 x 290 / 144
(incl. optical drive)
450 x 290 / 126
(incl. optical drive)
450 x 290 / 142
(incl. optical drive)
450 x 321 / 145
(incl. optical drive)
450 x 380 / 151
(incl. optical drive)
450 x 380 / 151
(incl. optical drive)
Install. dimensions, 368 x 290 x 123
centralized design
(W x H x D without
optical drive) in mm
450 x 290 x 105
450 x 290 x 121
450 x 321 x 124
450 x 380 x 130
450 x 380 x 130
Additional mounting 21 mm
depth (optical
drive)
21 mm
21 mm
21 mm
21 mm
21 mm
483 x 310
(19", 7 HU)
483 x 310
(19", 7 HU)
483 x 355
(19", 8 HU)
483 x 400
(19", 9 HU)
483 x 400
(19", 9 HU)
Install. dimensions, 368 x 290 x 87
operator panel with
distributed design
(W x H x D) in mm
450 x 290 x 69
450 x 290 x 85
450 x 321 x 89
450 x 380 x 94
450 x 380 x 94
Install. dimensions, 298 x 301 x 100;
computer unit with (298 x 301 x 80
distributed design without CD)
(W x H x D) in mm
298 x 301 x 100;
(298 x 301 x 80
without CD)
298 x 301 x 100;
(298 x 301 x 80
without CD)
298 x 301 x 100;
(298 x 301 x 80
without CD)
298 x 301 x 100;
(298 x 301 x 80
without CD)
298 x 301 x 100;
(298 x 301 x 80
without CD)
12 kg
14 kg
16 kg
18 kg
17 kg
Dimensions
Mounting
cutout/Device
depth (W x H / D)
in mm
Operator panel
(W x H) in mm
400 x 310 (7 HU)
Weights
• Panel PC in
central design,
approx.
3/22
13 kg
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Ordering data
Order No.
Order No.
Panel PC configurator (contract-based production and delivery)
SIMATIC Panel PC 677B
D
6AV7 87 7 - 7 7 7 7 7 - 7 7 7 0
Front panels
Panel PC configurator (continued)
SIMATIC Panel PC 677B
6AV7 87 7 - 7 7 7 7 7 - 7 7 7 0
D
Main memory
• 12" TFT Touch
0
• 1 GB DDR2
2
• 12" TFT Key
1
• 2 GB DDR2
3
• 15" TFT Touch
2
• 3 GB DDR2
4
• 15" TFT Key
3
• 4 GB DDR2
5
• 17" TFT Touch
4
Mass storage
• 19" TFT Touch
5
• 80 GB SATA hard disk
0
• 160 GB SATA hard disk
1
• RAID1 dual hard disk module
2 x 80 GB SATA, preconfigured
2
• Dual hard disk module 2 x 80 GB
SATA
3
• Second CF card slot (only in
combination with Windows XP
embedded), internal, not fitted,
only with version without opt.
drive and without HDD
4
Front options
• With front USB interface
0
• Without front USB interface
1
• INOX front, without front USB,
with 15" TFT Touch only
2
2
Power supply
• 24 V DC
A
• 110/230 V AC, power cable for
Europe
B
• 110/230 V AC (without power
cable)
C
3
Optical drives
• Without
0
• DVD±RW±R combo drive
1
• 110/230 V AC, power cable for
UK
D
• 110/230 V AC, power cable for
CH
E
• PROFIBUS/MPI; 2 x Gbit
Ethernet, 2 MB NV-RAM
A
• 110/230 V AC, power cable for
the USA
F
B
• 110/230 V AC, power cable for
Italy
G
• PROFINET (3 x RJ45, CP1616compatible); 2 x Gbit Ethernet,
2 MB NV-RAM6)
• 110/230 V AC, power cable for
China
H
Communication interfaces
Operating system
Processor
• Without operating system1)
A
• Windows 2000 Professional
Multi-Language2) 3)
B
• Windows XP Professional
Multi-Language2)
C
• Intel Celeron M 440 / 1.86 GHz,
533 MHz FSB, 1 MB SLC, slots
(spare): 2 x PCI
A
• Intel Celeron M 440 / 1.86 GHz,
533 MHz FSB, 1 MB SLC, slots
(spare): 1x PCIe x4 and 1x PCI
B
• Windows Vista Ultimate
Multi-Language5)
D
C
• Windows Server 2003 Standard
Edition incl. 5 Clients MUI7), SP1
(SP2 enclosed)
E
• Intel Core 2 Duo T5500 / Dual
Core, 1.66 GHz, 677 MHz FSB,
2 MB SLC, slots (spare): 2 x PCI
D
• Windows XP embedded
(English)4) on 2 GB CF card
F
• Intel Core 2 Duo T5500 / Dual
Core, 1.66 GHz, 677 MHz FSB,
2 MB SLC, slots (spare): 1x PCIe
x4 and 1x PCI
• Intel Core 2 Duo T7400 / Dual
Core, 2,16 GHz, 677 MHz FSB,
4 MB SLC, slots (spare): 2x PCI
E
• Intel Core 2 Duo T7400 / Dual
Core, 2,16 GHz, 677 MHz FSB,
4 MB SLC, slots (spare): 1x PCIe
x4 and 1x PCI
F
D) Subject to export regulations: AL: N and ECCN: 5D992B1
1)
Not with internal second CF card slot
2)
Multi-language means: D/E/F/I/SP/CHIN traditional/CHIN
simplified/Korean/Japanese
3)
With Windows 2000, only one core can be used with the dual-core
processors
4)
Only without RAID 1 option.
5)
Multi-language means: D/E/F/I/SP; other languages only by downloading
from Microsoft
6)
Not with Windows 2000 Professional
7)
Multi-language means: D/E/F/I/SP
Siemens ST 80 · 2009
3/23
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Ordering data (continued)
Order No.
Delivery variants (from stock)
12" TFT Touch
3
D
6AV7 870-0BC20-1AC0
110/230 V AC power supply
Core 2 Duo T5500, 1.66 GHz,
2 x PCI
1 GB RAM, 80 GB HDD,
DVD ± R ± RW burner
PROFIBUS/MPI
Windows XP Prof. MUI (SP2)
(D/F/I/SP/CHN traditional/CHN
simplified/Korean/Japanese)
12" TFT Key
6AV7 871-0BC20-1AC0
110/230 V AC power supply
Core 2 Duo T5500, 1.66 GHz,
2 x PCI
1 GB RAM, 80 GB HDD,
DVD ± R ± RW burner
PROFIBUS/MPI
Windows XP Prof. MUI (SP2)
(D/F/I/SP/CHN traditional/CHN
simplified/Korean/Japanese)
D
6AV7 872-0BC20-1AC0
6AV7 671-4BA00-0AA0
• for 17" Touch
6AV7 672-1CF00-0AA0
• for 19" Touch
6AV7 672-1CE00-0AA0
Labeling foils for Panel
PC 477/577/677(B)
6AV7 672-0DA00-0AA0
• 1 GB DDR2
A
6ES7 648-2AG40-0HA0
• 2 GB DDR2
A
6ES7 648-2AG50-0HA0
Direct control key module for
Panel PC 677(B)
A
6AV7 671-7DA00-0AA0
Option pack for direct control
key module
A
6ES7 648-0AA00-0XA0
Transfer module for interface connection to 16 I/Os
Non-heating apparatus cable
for SIMATIC Box and Panel PC
6AV7 873-0BC20-1AC0
110/230 V AC power supply
Core 2 Duo T5500, 1.66 GHz,
2 x PCI
1 GB RAM, 80 GB HDD,
DVD ± R ± RW burner
PROFIBUS/MPI
Windows XP Prof. MUI (SP2)
(D/F/I/SP/CHN traditional/CHN
simplified/Korean/Japanese)
D
6AV7 874-0BC20-1AC0
110/230 V AC power supply
Core 2 Duo T5500, 1.66 GHz,
2 x PCI
1 GB RAM, 80 GB HDD,
DVD ± R ± RW burner
PROFIBUS/MPI
Windows XP Prof. MUI (SP2)
(D/F/I/SP/CHN traditional/CHN
simplified/Korean/Japanese)
19" TFT Touch
6AV7 671-2BA00-0AA0
Memory expansion
D
17" TFT Touch
• for 12" Touch
• for 15" Touch
For labeling softkeys and function
keys, blank, supplied in sets of 10
110/230 V AC power supply
Core 2 Duo T5500, 1.66 GHz,
2 x PCI
1 GB RAM, 80 GB HDD,
DVD ± R ± RW burner
PROFIBUS/MPI
Windows XP Prof. MUI (SP2)
(D/F/I/SP/CHN traditional/CHN
simplified/Korean/Japanese)
15" TFT Key
Cover foil for Panel
PC 477/577/677(B)/Flat Panel,
set of 10 each
For protecting the touch screen
against dirt/scratches
D
15" TFT Touch
Order No.
Accessories
SIMATIC PC power cable,
230 V AC, angled, 3 m, for:
• Germany
6ES7 900-1AA00-0XA0
• United Kingdom
6ES7 900-1BA00-0XA0
• Switzerland
6ES7 900-1CA00-0XA0
• USA
6ES7 900-1DA00-0XA0
• Italy
6ES7 900-1EA00-0XA0
• China
6ES7 900-1FA00-0XA0
Mounting elements for
17"/19" Panel PC 577, 677(B)
6AV7 672-8KE00-0AA0
For screw mounting of the 17" and
19" touch front from the front1)
Touch pen
A
6AV7 672-1JB00-0AA0
Undetachable pen for operation
of the touch devices, mounting of
the support on the control cabinet
D
6AV7 875-0BC20-1AC0
110/230 V AC power supply
Core 2 Duo T5500, 1.66 GHz,
2 x PCI, 1 GB RAM, 80 GB HDD,
DVD ± R ± RW burner
PROFIBUS/MPI
Windows XP Prof. MUI (SP2)
(D/F/I/SP/CHN traditional/CHN
simplified/Korean/Japanese)
12" TFT Key with DC power
supply
24 V DC power supply
Celeron M440, 1.86 GHz, 2 x PCI
512 MB RAM, 80 GB HDD,
DVD ± R ± RW burner
PROFIBUS/MPI
Windows XP Prof. MUI (SP2)
(D/F/I/SP/CHN traditional/CHN
simplified/Korean/Japanese)
3/24
Siemens ST 80 · 2009
6AV7 871-0AA10-1AC0
A) Subject to export regulations: AL: N and ECCN: EAR99H
D) Subject to export regulations: AL: N and ECCN: 5D992B1
1)
No longer necessary for the 19" touch front from approximately December
2008
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Ordering data (continued)
Order No.
Expansion components
SIMATIC PC/PG DiagMonitor
V4.0
6ES7 648-6CA04-0YX0
Software tool for monitoring
SIMATIC PCs, incl. manual, on
CD-ROM (German/English)
SIMATIC PC Image Creator
V2.1
A
6ES7 648-6BA02-1YX0
6EP1 931-2EC41
with charger unit for 24 V
lead battery,
input 24 V DC/16 A,
output 24 V DC/15 A
6EP1 935-6MD11
3
for DC UPS module 15 A
A
6ES7 648-6AA02-1YX0
Communication components
PCI interface card
6ES7 648-2CA10-0AA0
With COM1, COM2 and
LPT interfaces
Software tool for hard-disk
partitioning for SIMATIC PCs,
incl. manual, on CD-ROM
(Eng/Ger/Fr/Sp/It)
SIMATIC PC USB FlashDrive
SITOP power, 15 A DC UPS
module, with USB port
SITOP power, battery module
24 V/3.2 Ah
Software tool for data backup for
SIMATIC PCs, incl. manual, on
CD-ROM (Eng/Ger/Fr/Sp/It)
SIMATIC PC Partition Creator
V2.1
Order No.
Uninterruptible power supplies
A
6ES7 648-0DC40-0AA0
A
6FC5 235-0AA05-1AA2
2 GB, USB 2.0; metal enclosure,
bootable
3.5" disk drive, USB
With 1 m connecting cable
SIMATIC Panel PC Remote Kit
for the separate configuration of
control unit and PC
• 24 V DC, 5 m
A
6AV7 671-1EA00-5AA1
• 24 V DC, 10 m
A
6AV7 671-1EA01-0AA1
• 24 V DC, 15 m
A
6AV7 671-1EA01-5AA1
• 24 V DC, 20 m
A
6AV7 671-1EA02-0AA1
• 24 V DC, 30 m
A
6AV7 671-1EA03-0AA1
• 110/230 V AC, 5 m
A
6AV7 671-1EA10-5AA1
• 110/230 V AC, 10 m
A
6AV7 671-1EA11-0AA1
• 110/230 V AC, 15 m
A
6AV7 671-1EA11-5AA1
• 110/230 V AC, 20 m
A
6AV7 671-1EA12-0AA1
• 110/230 V AC, 30 m
A
6AV7 671-1EA13-0AA1
Industrial USB Hub 4
A
6AV6 671-3AH00-0AX0
4 x USB 2.0 interfaces, IP65 for
control cabinet door or DIN rail
assembly
A) Subject to export regulations: AL: N and ECCN: EAR99H
Siemens ST 80 · 2009
3/25
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ Dimensions
3
H
G
M
K
J
G
H
J
K
L
M
N
Touch panels
12"
15"
17"
19"
289
289
378
378
271
271
271
271
141
138
147
147
11
11
11
11
53
24
18
18
369
367
376
376
71
42
36
36
Key panels
12"
15"
289
324
271
271
122
141
11
11
42
31
351
370
59
48
Operating unit and complete unit
Installation cutout
3/26
Siemens ST 80 · 2009
L
N
All dimensions without screw protrusions
G_ST80_XX_00288
Operator panels PC 677B
© Siemens AG 2008
SIMATIC Panel PC
SIMATIC Panel PC 677B (incl. INOX)
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/panel-pc
Note:
Do you a require specific modification or extension to the
products described here? You will find information about
additional, generally available sector-specific products, as well
as about options for customer-specific modification and
adaptation under "Customized products".
3
Siemens ST 80 · 2009
3/27
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC PC DiagMonitor
■ Overview
■ Function
The SIMATIC PC DiagMonitor monitors, signals and communicates with an external server, acts in the event of an alarm and
logs the system states of the SIMATIC PCs.
It monitors
• The processor and internal device temperatures
• Fans
• The system status by means of a "watchdog"
• The function of the hard disk or RAID 1
• Wear and tear limits in the CompactFlash Card (available
soon)
3
The SIMATIC PC DiagMonitor software for monitoring and
remote signaling detects possible hardware and software faults
at an early stage. It monitors, signals and visualizes the
operating statuses of the SIMATIC PC both locally and remotely.
It is used with the following SIMATIC PCs:
• Microbox PC 427B
• Box PC 627B/827B
• Rack PC IL 43/547B/847B
• Panel PC 477B/577B/677B
And can be ordered directly via the PC Configurator or as an
individual product.
■ Benefits
Investment security thanks to increased system availability
• Diagnostics and signaling functions for PC temperature, fan,
hard disks (SMART), watchdog
• Operating hours counter for preventive maintenance
• Integral log function, comprehensive text messages, online
help English/German
• Worldwide diagnostics over the Internet thanks to integrated
web server function
Reduced costs thanks to reduced downtimes
• Fast information thanks to communication via e-mail and SMS
• Fast response thanks to communication in the application
through OPC (client) and SNMP
It signals
• The number of operating hours for activating maintenance
periods
• Each alarm and logs it
• Overshoot/undershoot of permissible operating temperature
• Program interruption following a watchdog timeout
• Hard disk problems through evaluation of the S.M.A.R.T
diagnostic bytes
It communicates
• Locally with an OPC client
• Locally via DLL or SNMP with a central server
• Remotely over LAN, by e-mail, text messages
• With diagnostic LEDs on the device
• Worldwide over the Internet through a web server
It acts in the event of an alarm
• By starting customer applications
• By executing a "Reset"
• By simple integration/activation
It logs
• All messages and commands in a log file automatically
• The measuring data (temperature, fan) over the operating
period
It visualizes
• The recorded measuring data (with trend analysis)
It synchronizes
• System time over LAN (e.g. maintenance-free operation
without CMOS battery)
Furthermore, customers have the option of creating their own
applications via a programming interface.
System requirements:
Executes under Windows 2000/XP Professional/XP embedded,
Win 2003 Server, Win Server 2003 R2, Windows Vista
Ultimate/Business.
■ Ordering data
SIMATIC PC DiagMonitor V4.0
Software tool for monitoring the
SIMATIC PC, incl. manual on CD
ROM (English, German), single
license
3/28
Siemens ST 80 · 2009
Order No.
6ES7 648-6CA04-0YX0
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC PC BIOS Manager
■ Overview
■ Function
The SIMATIC PC BIOS Manager offers the following functions:
• reading CMOS data from the BIOS
• saving CMOS data in a file tagged with a user text
• writing the saved CMOS data into BIOS
• scanning BIOS DMI data
• saving BIOS DMI data in a text file (basic format for printer
output)
• switching language (German/English)
• help function
System requirements:
The SIMATIC PC BIOS Manager is a software tool that is used to
process CMOS and DMI data from the BIOS configuration of a
SIMATIC PC.
The tool is obtained by downloading it from the Internet using the
Automation Value Card from Customer Support.
http://www.siemens.com/simatic/bios-manager
■ Benefits
Productivity increase due to efficient and user-friendly BIOS
data management
• CMOS data duplicated by means of reading out, saving in a
file, writing to the CMOS
• CMOS data saved for documentation and restore purposes
• DMI data read out and saved as a text file (e.g. PC serial
number)
The SIMATIC PC BIOS Manager executes with all SIMATIC PCs
in combination with MSDOS 6.x or FreeDOS.
DOS (FreeDOS), which is necessary for creating a bootable
diskette, is included in the download.
■ Ordering data
Order No.
SIMATIC PC BIOS Manager
As download from
Customer Support
Software tool for processing
special BIOS data (CMOS, DMI
data) for SIMATIC PCs
http://www.siemens.com/
simatic/bios-manager
■ Application
Wherever the SIMATIC PC is put to industrial use, it is expanded
by both modules and software and the BIOS settings (CMOS
data) modified accordingly. In this environment, the SIMATIC PC
BIOS Manager is used as:
Production tool
For quick configuration of identical CMOS data
• Reading CMOS data from the BIOS
• Saving CMOS data in a file tagged with a user text
• Writing the saved CMOS data into BIOS
Service/quality tool
• Quick, simple storage of PC system data for QM purposes
• CMOS data transferred to an end user
• Uncomplicated CMOS restoration on site
Siemens ST 80 · 2009
3/29
3
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC PC Image Creator
■ Overview
■ Benefits
Data security at low cost
Hard disk contents can be saved quickly accurate to a bit and
securely.
Reduced costs thanks to reduced downtimes
A significantly shorter time is required to restore a hard disk
installation than is required for a new installation.
• After a hard disk is replaced, SIMATIC PCs are ready for
operation again in just a few minutes.
• Software failures due to application errors, operator errors or
computer viruses can be rectified in a matter of minutes.
• The most recently backed up hard disk contents are restored
quickly, reliably and accurate to a single bit.
3
■ Application
SIMATIC PC Image Creator is used for preventive data backup
of hard disk contents.
SIMATIC PC Image Creator is the software tool for quick and
easy back-up and restoring of the content of hard disks (images
of individual partitions or complete hard disks). This software
can be ordered via the SIMATIC PC configurator or as an
individual product via order number.
The product is designed for extremely easy handling:
• Executable on all SIMATIC PCs
• Operating system-dependent application by starting from
own execution environment
• Direct starting by booting the CD, no installation required.
• Menu-driven creation of a bootable USB FlashDrive as an
alternative start medium
• Menu-driven expansion of a USB FlashDrive with Partition
Creator (and BIOS manager, if applicable) to "Tools Stick" with
Image & Partition Creator (& BIOS manager)
• "1ClickImage" for routine backups, also time-controlled
3/30
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC PC Image Creator
■ Function
Basic functionality
• High-speed and accurate backup and restoring of hard disk
contents. This restoration requires considerably less time
compared to a reinstallation.
• Consistently integrated menus allow easy operation so that
the user does not require specialist knowledge.
• SIMATIC PC Image Creator backs up the hard disk image
optionally on :
- Second partition
- Second hard disk
- CD/DVD burner drive
- USB-CD/DVD burner drive or USB hard drive
- A server or directly connected PC
• Image Creator can be started directly from the CD, with its full
scope of functions, without the need for installation (exception:
"1ClickImage" backup). In this case there is no change to the
target system to be backed up, which rules out from the start
the possibility of unwanted conflicts with the existing installation.
• Can be used on all SIMATIC PCs, regardless of the processor,
memory or hard drive equipment
• SIMATIC PCs are supported automatically by integration of
the correct drivers.
• The CD can also be booted from an external USB-CD/DVD
drive (if supported by the device).
• If no CD/DVD drive is available, boot diskettes or a bootable
USB flash drive (if supported by the device) can be set up as
alternative execution media.
• Image Creator is based on Symantec Norton Ghost 2003.
Special product features
• Installation of Image Creator is possible in hidden area on the
hard disk (requirement for "1ClickImage"). This means that
Image Creator is always on board (--> no Image Creator CD
or USB Flash Drive required). The following functions are then
possible:
• Image Creator can be started in Windows (even if Ghost is not
installed). In this case, Windows is shut down and Image
Creator is booted from the hidden area of the hard disk.
• Complete backup via mouse double-click with "1ClickImage"
after one-time setup of backup path.
- This makes an extremely simple backup procedure
- The behavior of the PC after backup (e.g.: shut down, reboot
Windows) can be determined when configuring the backup.
- Log of backup procedure is maintained in a log file. This
means you can check later whether an unsupervised
backup has been performed correctly.
- Versioning of the "1ClickImage" backups (administration of
up to nine backups). This reliably protects older backup
states from inadvertent overwriting.
• Time-controlled backup: The start of a previously configured
complete backup via the Windows Task Planner enables
regular, unsupervised backups at any times
• Creation of an "Image Creator Stick"
• When menu-driven, a USB FlashDrive can be set up as an
execution medium for Image Creator. If BIOS Manager is
installed on the USB FlashDrive, it is integrated into the
operating menu.
• Generation of a "Tool Stick"
• Image Creator can be added onto an USB Flash Drive with
BIOS Manager and/or Partition Creator. After booting the USB
Flash Drive, you can then call Image Creator or Partition
Creator or BIOS-Manager from a selection menu.
• Menu-driven generation of a Windows boot menu entry for the
USB FlashDrive makes the migration of the booting sequence
in favor of the USB FlashDrive in the BIOS unnecessary.
System requirements:
Can run on a SIMATIC PC with Windows 2000/XP/Vista
Note:
The standard installation of Ghost 2003 is not possible in
Windows Vista. The backup and restoration of Vista systems
from the Image Creator runtime environment is possible,
however, without restrictions (also "1ClickImage").
■ Ordering data
SIMATIC PC Image Creator
V2.1
Order No.
A
6ES7 648-6BA02-1YX0
Software tool for data backup for
SIMATIC PCs, incl. manual, on
CD-ROM (Eng/Ger/Fr/Sp/It)
A) Subject to export regulations: AL: N and ECCN: EAR99H
Siemens ST 80 · 2009
3/31
3
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC PC Partition Creator
■ Overview
■ Benefits
Hard disk partitions can be modified without the need for
reinstallation
SIMATIC PC Partition Creator facilitates modification of hard disk
partitions to suit changed requirements without the need for
reinstallation. The existing installation remains executable.
■ Application
SIMATIC PC Partition Creator is used for modifying the pre-set
hard disk partitioning to suit new requirements.
3
SIMATIC PC Partition Creator is a software tool which enables
easy post modification of hard disk partitions without loss of
data.
The product is designed for extremely easy handling:
• Executable on all SIMATIC PCs
• Direct starting by booting the CD, no installation required
• Menu-driven creation of a bootable USB FlashDrive as an
alternative start medium for the Partition Creator.
• Menu-driven expansion of a USB FlashDrive with
Image Creator (and BIOS manager, if applicable) to the
"Tools Stick" with Image & Partition Creator (& BIOS manager)
Operating system-independent application by starting from own
execution environment.
3/32
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC PC Partition Creator
■ Function
Basic functionality
• SIMATIC PC Partition Creator can be started directly from the
CD with its full scope of functions, without the need for
installation on the IPC.
• The CD can also be booted from an external USB-CD/DVD
drive (if supported by the device)
• If no CD/DVD drive is available, boot diskettes or a bootable
USB FlashDrive (if supported by the device) can be set up
as alternative execution media.
• Partition Creator is based on Symantec Partition Magic 8.0
■ Ordering data
SIMATIC PC Partition Creator
V2.1
Order No.
A
6ES7 648-6AA02-1YX0
Software tool for hard-disk
partitioning for SIMATIC PCs,
incl. manual, on CD-ROM
(Eng/Ger/Fr/Sp/It)
A) Subject to export regulations: N and ECCN: EAR99H
3
SIMATIC PC Partition Creator provides the following functions for
modifying hard disk partitions:
• Enlarge or reduce existing system and data partitions without
any loss of data
• Set up new partitions or delete existing ones
• Simple setup of multiple-boot systems. Installation of a boot
manager
Special product features
• Creation of a Partition Creator Stick
When menu-driven, a USB FlashDrive can be set up as an
execution medium for Partition Creator. If BIOS Manager is
installed on the USB FlashDrive, it is integrated into the
operating menu.
• Creation of a Tools Stick
Partition Creator can be added onto a USB FlashDrive with
BIOS Manager and/or Image Creator. After booting the USB
FlashDrive, you can then call Image Creator or Partition Creator or BIOS-Manager from a selection menu.
• Menu-driven generation of a Windows boot menu entry for the
USB FlashDrive makes the migration of the booting sequence
in favor of the USB FlashDrive in the BIOS unnecessary.
System requirements:
Can run on a SIMATIC PC with Windows 2000/XP
Notes:
• The SIMATIC PC Partition Creator cannot be used on systems
with Windows Server operating systems!
The SIMATIC PC Partition Creator cannot be used on systems
with Windows Vista operating systems!
Siemens ST 80 · 2009
3/33
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC PC USB FlashDrive
■ Overview
■ Function
3
The SIMATIC PC USB FlashDrive is the ideal mobile storage
medium for SIMATIC PCs/PGs.
Thanks to the rugged and ultra-compact construction in a metal
enclosure, fast data transfer (USB 2.0) and the high memory
capacity of 2 GB, the USB FlashDrive is ideally suited for use in
industrial applications.
It replaces diskettes, CD and DVD read/write media as data
memory. Thanks to its high access speed, it is also ideal for tools
that are not to be installed on the computer (portable applications). In addition, it can be set up ready to boot using SIMATIC
PC BIOS-Manager. There is an option of expanding the USB
FlashDrive set up in this way into a "tool stick" using SIMATIC
PC Image and/or SIMATIC PC Partition Creator.
■ Benefits
Recommended operating systems:
Windows 2000/XP/Vista
■ Technical specifications
SIMATIC PC USB Flash Drive
Supported operating systems
Windows 2000/XP/Vista
Capacity
2 GB
Approvals
CE Industry
Temperature
Ultra-compact, rugged and industry-standard
• SLC-Flash technology for maximum data security and
performance
• High level of electromagnetic compatibility according to
CE Industry when operated with SIMATIC PC
• Especially suitable for use in industrial environments thanks
to the metal enclosure
• Two USB FlashDrives can be inserted one above the
other/side by side
High degree of investment protection
• System tested with SIMATIC PC/PG (hardware and software)
• Can be used to transfer Automation License Keys
(requirement: Automation License Manager, V2.x and higher)
Added value
• SIMATIC PC BIOS-Manager (DOS and Windows version)
included in scope of supply
■ Application
The SIMATIC PC USB FlashDrive is a fast and simple method
of saving your data (e.g. recipes, configuration data, etc.) and
transporting them easily from one place to another, or it can be
used as starting medium for SIMATIC PC BIOS-Manager,
SIMATIC PC Image Creator or SIMATIC Partition Creator. In
addition, it is ideal as a storage medium for portable applications.
3/34
Functional highlights/outstanding technical features
• Rugged metal enclosure, ultra-compact design (dimensions:
64 x 18.5 x 7.8 mm) and high electromagnetic compatibility in
accordance with CE Industry make the stick particularly
suitable for industrial use.
• High memory capacity of 2 GB
• SLC-Flash technology for maximum data security and
performance
• High data transmission rate (USB 2.0 interface)
• Bootable with operating system (FreeDOS) and the auxiliary
tool SIMATIC PC BIOS-Manager (DOS and Windows version)
after short set-up procedure.
• Ideal as boot medium for SIMATIC PC Image & Partition
Creator. "Tool stick" can be generated with BIOS-Manager,
Image Creator and Partition Creator
• Immediately ready to use – "plug & play", no driver necessary
(Windows 2000 or higher)
• Status LED for indicating the operating state and data
transmission
• System-tested with SIMATIC PC/PG
Siemens ST 80 · 2009
• During operation
+5 ... +55 °C
• Storage
-20 ... +70 °C
Device dimensions
(L x W x H) in mm
64 x 18.5 x 7.8
Weight
12 g
Weight, approx.
12 g
■ Ordering data
Order No.
SIMATIC PC USB FlashDrive A
2 GB, USB 2.0, metal enclosure,
boot capability, for SIMATIC PC:
Rack PC, Box PC and Panel PC
(477 Embedded/577/677/877)
and for SIMATIC PG
• 1 ... 9 units
6ES7 648-0DC40-0AA0
• 10 units and above
6ES7 648-0DC40-0AA0
• 100 units and above
6ES7 648-0DC40-0AA0
A) Subject to export regulations: AL: N and ECCN: EAR99H
Note:
For orders of more than 100, delivery time may be extended.
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
3.5" floppy disk drive USB 1.1
■ Overview
■ Technical specifications
Floppy disk drive USB 1.1
Input voltage
5.25 V DC
Power consumption, max.
2.5 W
Degree of protection to EN 60529
(IEC 60529)
Front
IP54
Rear
IP00
Humidity rating in accordance
with EN 60721-3-3
Class 3K5 condensation and icing
excluded. Low air temperature
0 °C (32 °F).
Relative humidity
The 3.5" floppy disk drive is suitable for archiving user data and
can be installed in front panels. The connection is made via the
USB interface.
■ Function
The 3.5" floppy disk drive is designed for the transfer of user
data. Installation in front panels makes it possible to transfer
data without opening the control cabinet door. You can use high
density (1.2/1.44 MB) 3.5" floppy disks to store user data.
■ Integration
The floppy disk drive is suitable for connecting to:
• SINUMERIK PCU 50/PCU 70 with Windows XP
• SINUMERIK PCU 50/PCU 70 with Windows NT 4.0 and
PCU-Base software 07.03.03 or higher
• SINUMERIK PCU 50.3
• SINUMERIK TCU
• SIMATIC Panel PC 67x/87x/477/577 with Windows 2000/XP
• SIMOTION P350 with Windows XP Professional
Storage
5 ... 90 % at -22 ... +60 °C
(-8 ... +140 °F)
Transport
5 ... 95 % at -40 ... +65 °C
(-40 ... +149 °F)
Operation
20 ... 80 % at 4 ... 51.7 °C
(39 ... 125 °F)
Ambient temperature
Storage
-20 … +60 °C (-4 ... +140 °F)
Transport
-20 … +60 °C (-4 ... +140 °F)
Operation
4 … 50 °C (39.2 ... 122 °F)
Distance to PCU
5 m (16.4 ft)
Dimensions
Width
145 mm (5.71 in)
Height
50 mm (1.97 in)
Depth
161 mm (6.34 in)
Weight, approx.
0.32 kg (0.71 lb)
■ Ordering data
SINUMERIK 3.5" floppy disk
drive, USB 1.1
Incl. connecting cable
Length: 1 m (3.28 ft)
Order No.
A
6FC5235-0AA05-1AA2
Accessories
Cover
For SINUMERIK floppy disk drive
and card reader with masking
frame, cover, and bearing bracket
6FC5247-0AA20-0AA0
A) Subject to export regulations: AL: N and ECCN: EAR99H
■ More information
Note for SIMATIC Panel PCs
The USB floppy disk drive is approved for the Windows 2000/XP
operating systems. The appropriate drivers for the floppy disk
drive are supplied with the operating system software.
Note for SINUMERIK PCU 50/PCU 70
A SINUMERIK PCU 50/PCU 70 (566 MHz/1.2 GHz) with BIOS
V02.03.07 and Windows NT4.0 V07.03.03 or Windows XP
V07.03.02.01 operating system is required to operate the USB
floppy disk drive.
Siemens ST 80 · 2009
3/35
3
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC Panel PC Remote Kit
■ Overview
■ Technical specifications
SIMATIC Panel PC Remote Kit
Design
Subsequent installation on the
Panel PC 677, 677B operator
control unit
Supported operator control
units
All Panel PC 677, 677B operator
control units:
• 12" Touch/Key
• 15" Touch/Key
• 17" Touch (only available on
Panel PC 677B)
• 19" Touch
Cable sets
•5m
• 10 m
• 15 m
• 20 m
• 30 m
Front panel functionality
As centralized installation with the
following constraint in respect of
USB functionality:
• Distance 5 m: USB 2.0, and
only one external 2.0 Hub
• Distance > 5 m: USB 1.1, and
only one external 1.1 Hub
External ports
2 additional USB ports on the
remote module (on the rear of the
remote operator control unit)
Power supply
24 V DC; 20.4 to 28.8 V DC or
110 to 240 V AC; 50/60Hz
Approvals
CE, cULus (UL 508)
Scope of supply
• Remote module
• Cable set
• Mounting accessories for the
PC677(B) computer unit
• European power supply cable
(with the AC option)
3
The Remote Kit makes it possible to separate the Panel PC
677/677B operator control unit from the computer unit and install
them up to 30 m apart.
■ Benefits
• Maintaining the Panel PC front functionality
- Status LEDs (temperature/power)
- LEDs on the keys, Piezo mouse
- USB 2.0 on front (up to 5 m), USB 1.1 (up to 30 m)
- Dimmable backlit display
- Programmable keyboard controller
- Direct control key module option available and mountable
• Makes an ultra-compact operator control unit possible
• Suitable for subsequent modification/upgrade by the
customer
• Applicable for all SIMATIC Panel PCs 677 and 677B
• Pure hardware solution and, therefore, independent of the
operating system
• Remote front with the option of AC or DC power supply
• Operator control unit can be located up to 30 m away from the
computer unit
• Two additional USB ports on rear, USB 2.0: up to 5 m highspeed, up to 30 m full-speed
■ Application
The Panel PC Remote Kit is designed for use exclusively with a
Panel PC 677 or Panel PC 677B. BIOS version V05.01.05 or
higher is required when using a Panel PC 677. The Remote Kit
can only be operated using the cables included in the scope of
delivery.
■ Design
The Remote Kit consists of the following components:
• Remote module (mounted on the rear of the operator control
unit)
• Video connecting cable (industrial grade DVI-D cable)
• USB connecting cable (up to 5 m with a standard USB cable;
at 5 m and longer, the USB signal is transmitted via a CAT6
cable with external amplification)
• Mechanical components (for mounting the computer unit
inside a control cabinet, console or machine)
3/36
Siemens ST 80 · 2009
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
SIMATIC Panel PC Remote Kit
■ Ordering data
Order No.
Order No.
SIMATIC Panel PC Remote Kit
Accessories
24 V DC, 5 m
A
6AV7 671-1EA00-5AA1
24 V DC, 10 m
A
6AV7 671-1EA01-0AA1
24 V DC, 15 m
A
6AV7 671-1EA01-5AA1
24 V DC, 20 m
A
6AV7 671-1EA02-0AA1
24 V DC, 30 m
A
6AV7 671-1EA03-0AA1
100/240 V AC, 5 m
A
6AV7 671-1EA10-5AA1
100/240 V AC, 10 m
A
6AV7 671-1EA11-0AA1
100/240 V AC, 15 m
A
6AV7 671-1EA11-5AA1
100/240 V AC, 20 m
A
100/240 V AC, 30 m
A
Sub-components of the
Remote Kit
(only available individually as
spare parts)
24 V DC remote module with
fixing accessories
A
6AV7 671-1EX01-0AD0
110 … 240 V AC remote module A
with fixing accessories
6AV7 671-1EX01-0BD0
USB amplifier/CAT6 converter
6AV7 671-1EX02-0AB0
6AV7 671-1EA12-0AA1
5 m cable set (DVI, USB standard
cable)
6AV7 671-1EX10-5AA0
6AV7 671-1EA13-0AA1
10 m cable set (DVI, Cat 6 cable)
6AV7 671-1EX11-0AA0
15 m cable set (DVI, Cat 6 cable) A
6AV7 671-1EX11-5AA0
20 m cable set (DVI, Cat 6 cable)
6AV7 671-1EX12-0AA0
30 m cable set (DVI, Cat 6 cable)
6AV7 671-1EX13-0AA0
3
Power supply cable
A) Subject to export regulations: AL: N and ECCN: EAR99H
Europe: D/F/NL/E/B/A/S/FIN1)
6ES7 900-1AA00-0XA0
United Kingdom
6ES7 900-1BA00-0XA0
Switzerland
6ES7 900-1CA00-0XA0
USA
6ES7 900-1DA00-0XA0
Italy
6ES7 900-1EA00-0XA0
China
6ES7 900-1FA00-0XA0
1)
A European power supply cable is included in the scope of delivery of the
AC (100 … 240 V) version of the Remote Kit.
■ Dimensions
Front dimensions
H
400
483
483
310
310
400
483
483
310
355
H
W
Touch panels
12"
15"
19"
Key Panels
12"
15"
D
10,5
Installation cutout
W+1 (cutout)
H+1 (cutout)
Touch panels
12"
15"
19"
Key Panels
12"
15"
W+1
H+1
D
368
450
450
290
290
380
95
93
102
450
450
290
321*
77
96
* In addition: two recesses 25 x 5 mm on the top side
for keyboard slide-in label channels
Siemens ST 80 · 2009
G_ST80_XX_00267
W
3/37
© Siemens AG 2008
SIMATIC Panel PC
Expansion components
Industrial USB Hub 4
■ Overview
■ Technical specifications
Industrial USB Hub 4
General information
belongs to product/product range MP 277, Panel PC
Supply voltage
24 V DC
permissible range
+20.4 V to +28.8 V DC
Degree of protection
3
IP65 at front
Yes
IP20 rear
Yes
Certifications & Standards
Certifications
CE
Ambient conditions
max. relative humidity (in %)
90%
Temperature
• The Industrial USB Hub 4 is used as a USB hub for the
connection of peripheral devices to Multi Panels, Panel PCs
and standard PCs.
• The industrial USB Hub 4 with IP65 degree of protection on the
front (Service Kit required) can be mounted in a control
cabinet. This simplifies the use of USB peripherals in harsh
industrial environments.
• USB peripherals can be connected to the panel and operated
via the Industrial USB Hub 4 without opening the cabinet door.
The ports are also accessible from the rear even in the control
cabinet.
■ Design
• Operation (vertical installation)
0 °C to +50 °C
• Transport, storage
-20 °C to +60 °C
Interfaces
Number of interfaces/according
to USB
Dimensions
External dimensions (W x H x D) in 212 x 156 x 50
mm
Weights
• Weight
In addition, the Industrial USB Hub4 has the following features:
• Inspection window for each interface
• Vibration-proof restraint of connected USB cables and USB
sticks
• One LED per interface for checking the data traffic
• Sufficient interior space for easy insertion and removal of
connections
• Facility for attachment to a DIN rail
• Voltage connection for 24 V DC
0.5 kg
■ Ordering data
Industrial USB Hub 4
Use of the Industrial USB Hub 4
• permits the simultaneous connection of as many as four
peripheral devices such as USB stick, mouse, keyboard,
printer or barcode reader to the panel.
• increases the availability of the system to be operated. The
cabinet door no longer has to be opened in order to connect
to the peripherals. The unit can be operated from the Panel PC
and the Multi Panel without interruption.
4; 500 mA each, e.g. mouse,
keyboard, printer, USB stick
Service pack for Industrial USB
Hub 4
Order No.
A
6AV6 671-3AH00-0AX0
See HMI Accessories "Service
packages" (incl. IP65 expansion)
A) Subject to export regulations: AL: N and ECCN: EAR99H
■ More information
Note for SIMATIC Panel PCs
The Industrial USB Hub 4 is approved for the Windows
CE/2000/XP operating systems. The appropriate drivers are
supplied with the operating system software.
■ Integration
The Industrial USB Hub 4 is suitable for connection to:
• Multi Panels
• SIMATIC Panel PC
• Standard PC
Recommended operating systems:
Windows CE/2000/XP/XP embedded
■
3/38
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
4/2
4/2
Introduction
Overview
4/5
4/5
SIMATIC WinCC flexible
engineering software
SIMATIC WinCC flexible ES
4/10
4/10
SIMATIC WinCC flexible ES options
WinCC flexible /ChangeControl
4/11
4/11
SIMATIC WinCC flexible runtime
software
SIMATIC WinCC flexible RT
4/18
4/18
4/20
4/22
4/23
4/25
4/29
4/32
4/34
SIMATIC WinCC flexible RT options
WinCC flexible /Archives
WinCC flexible /Recipes
WinCC flexible /Audit
WinCC flexible /SIMATIC Logon
WinCC flexible /[email protected]
WinCC flexible /[email protected]
WinCC flexible /OPC Server
WinCC flexible /ProAgent
4/35
4/35
4/51
4/52
4/53
4/58
4/59
4/60
4/64
4/65
4/67
4/69
4/71
SCADA system SIMATIC WinCC
SIMATIC WinCC
WinCC options
WinCC/Server
WinCC/Web Navigator
WinCC/Central Archive Server (CAS)
WinCC/Redundancy
SIMATIC Maintenance Station
WinCC/ProAgent
WinCC/DataMonitor
WinCC/DowntimeMonitor
WinCC/ProcessMonitor
WinCC/Connectivity Pack &
WinCC Connectivity Station
WinCC/IndustrialDataBridge
WinCC/Client Access License (CAL)
WinCC/User Archives
SIMATIC BATCH (for WinCC)
WinCC/ChangeControl & WinCC/Audit
SIMATIC Logon
WinCC/IndustrialX
WinCC/ODK
WinCC/Comprehensive Support
WinCC Premium Add-ons and
partner management
4/73
4/75
4/76
4/77
4/80
4/82
4/83
4/84
4/85
4/86
4/88
4/88
SIMATIC ProAgent process
diagnostics software
SIMATIC ProAgent
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
Introduction
■ Overview
With the SIMATIC WinCC flexible and SIMATIC WinCC product
families, SIMATIC HMI offers visualization and configuration software for the complete scope of applications:
• SIMATIC WinCC flexible
covers applications directly at the machine ranging from
PC-based HMI solutions for single-user systems based on
WinCC flexible Runtime through to the SIMATIC HMI operator
panels. For configuration the WinCC flexible Runtime for PCs
as well as SIMATIC HMI devices, the WinCC flexible family
also offers the integrated and scalable configuration tools
WinCC flexible Micro, WinCC flexible Compact, WinCC
flexible Standard and WinCC flexible Advanced.
• SIMATIC WinCC
is the process visualization or SCADA system (PC-based HMI
system) for visualizing and controlling processes, production
flows, machines and plants in all sectors – from the simple
single-user system through to the distributed multi-user system with redundant servers and remote solutions with Web
clients. WinCC is, at the same time, the information hub for
company-wide vertical integration (process visualization and
platform for IT and business integration).
is the consistent further development of the SIMATIC HMI
software products. WinCC flexible offers an essential hub for
applications close to the machine (until now this has been
covered by the ProTool family) with respect to configuration
efficiency and new automation concepts. For process-oriented
plant and mechanical engineering as well as series production
of machines, SIMATIC WinCC flexible also offers:
• Further productivity improvements (configuration efficiency)
when creating HMI projects
• Implementation of innovative TCP/IP and web-based automation and HMI concepts
• Increase of the availability of the machines and systems
through new service concepts
• Safe, flexible and world-wide access to process data
• Configuration of SIMATIC HMI devices
WinCC RC
Engineering Software
WinCC flexible Advanced
WinCC flexible Standard
WinCC flexible Compact
WinCC flexible
Micro
4/2
SIMATIC Micro Panel
TP177micro
OP73micro
Siemens ST 80 · 2009
SIMATIC Panels
70/170 series
SIMATIC Panels
and Multi Panels
170/270/370
series
PC based
WinCC flexible
Runtime
PC based
WinCC
Runtime
G_ST80_XX_00080
Runtime Software
4
SIMATIC WinCC flexible
© Siemens AG 2008
HMI Software
Introduction
■ Overview (continued)
Changing from the ProTool family to WinCC flexible is possible
by simply using the same or converting the old configuration
data.
SIMATIC WinCC will remain the process visualization system for
plant monitoring with single or multiple station solutions and the
platform for IT & Business integration under Windows 2000, XP
Professional and Windows Vista.
The next step will be to use WinCC flexible also as the platform
for integrating the SIMATIC WinCC visualization system. As is the
case today for ProTool V6 projects, WinCC V6 projects will then
also be compatible.
SIMATIC WinCC flexible ES engineering software
• Newly developed family of configuration systems with WinCC
flexible Micro/Compact/Standard/Advanced for SIMATIC
operator panels, the HMI part of SIMATIC C7 as well as for the
PC-based visualization software WinCC flexible RT
- SIMATIC Micro Panels
- SIMATIC Basic Panels
- SIMATIC Mobile Panels
- SIMATIC Panels of the 70/170/270 series as well as C7-635
and C7-636
- SIMATIC Multi Panels of the 170/270/370 series
- SIMATIC WinCC flexible RT
• Executable under Windows XP Professional/VISTA Business,
Ultimate
• Expanded integration into Totally Integrated Automation (TIA):
STEP 7, SIMOTION
• Maximum configuration efficiency thanks to preconfigured
objects, modular system, intelligent tools and mass data
processing
• Optionally expandable with functions for version administration and logging changes (WinCC flexible/ChangeControl)
SIMATIC WinCC flexible Runtime visualization software
• Modular PC-based HMI solution for single-user systems
directly at the machine (further development of ProTool/
Pro RT)
• Executable under Windows XP Professional/VISTA Business,
Ultimate
• Basic package providing a cost-effective means of getting
started in respect of visualization, signaling and logging. can
be expanded specifically with option packages
• Flexible expansion possible with VB scripts and customized
ActiveX controls created with OPP (Open Platform Program)
• Can be integrated into innovative automation solutions based
on TCP/IP networks
• Expanded service concepts with remote operation, diagnostics and administration over the intranet and Internet as well as
e-mail communication (using options)
• Can be expanded with WinCC flexible/Audit for recording operations in an audit trail
• Central, system-wide user management based on the
SIMATIC Logon option
SIMATIC WinCC process visualization system
• PC-based operator control and monitoring system for visualizing and operating processes, production flows, machines and
plants in all sectors - with the simple single-user station
through to distributed multi-user systems with redundant
servers and cross-location solutions with Web clients. WinCC
is the information hub for company-wide vertical integration
(process visualization and platform for IT & business integration).
• For universal use thanks to solutions for all sectors, e.g.
conforming to FDA 21 CFR Part 11, and multiple languages for
worldwide use
• All HMI functions on-board with industry-standard functions
for signaling and acknowledging events, archiving of
messages and measured values, logging of all process and
configuration data, user administration and visualization
(WinCC basic software).
• Configuring is easy and efficient using object libraries, modular systems, tools for mass data processing and online loading
of changes
• Company-wide, flexible client/server structures with operator
stations on the Web, distributed servers and data integrity
thanks to redundancy
• Easy to integrate over standard interfaces such as OPC (OLE
for Process Control), WinCC OLE-DB, VBA (Visual Basic for
Applications), VB script, C-API (ODK)
• Integration platform in the company thanks to the Historian
functionality integrated into WinCC based on the Microsoft
SQL Server 2005, standard and programming interfaces and
tools and clients for evaluation
• Modular expansion with options and add-ons as well as individual function expansions with VB Script, Visual Basic for
Applications, C-API (ODK) and integration of ActiveX
elements
• Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes engineering outlay, reduces
lifecycle costs
Siemens ST 80 · 2009
4/3
4
© Siemens AG 2008
HMI Software
Introduction
■ Overview (continued)
SIMATIC WinCC flexible Runtime
SIMATIC WinCC
Area of application
HMI software designed primarily for use in
in-process applications in (series) machine
production
Process visualization software for controlling and
monitoring both simple and complex automation
solutions
Configurations
Single-user system, usually based on a panel PC
Single- and multi-user system as well as distributed systems
Support of simple distributed operating stations in Internet capability using the
TCP/IP networks
WinCC/Web Navigator option
Innovative service concepts featuring e-mail,
remote control, monitoring and administration via
intranet/Internet
Data integrity with redundant solutions
Integrated Historian functionality
Processing of high quantity frameworks
4
Strategies
Integrated solution system taking in both operator
panels and PC-based operator stations running
WinCC flexible Runtime
High-quality SCADA functionality and integration
platform for ERP/MES solutions based on the
integrated Historian functionality (IT & business
integration)
Configuring
An integrated family of configuration tools for
integrated solutions
Flexibility thanks to individual dynamization
options
Fast configuration due to preconfigured objects
and referenced image blocks
Object library and function block technology
(incl. referencing)
Table-based editors for efficient mass data
processing
Efficient configuration of mass data thanks to
configuration tool
Intelligent tools to simplify the configuration of
complex tasks, e.g., user guidance, automatic
compilation
Simple configuration of control system
applications, text library for signaling system
Online loading of changes in active projects
Functional scope
HMI basic functionality can be expanded using
option packages
High-performance and comprehensive SCADA
functionality
Standard functions can be expanded quickly
and easily using VB scripts
Standard functions can be expanded quickly and
easily using VB scripts and C scripts
Integral component of the PCS 7 process control
system
Openness/expansion capability
Custom made solutions based on ActiveX controls Can be expanded with open Windows interfaces
are possible (Open Platform Program)
for integration into a factory-/company-wide
information system
Access to runtime display objects using VB scripts Standard SQL database with WinCC OLE DB
Provider
C-APIs (ODK), access to the COM object model of
WinCC RT using VB script and WinCC CS using
VBA
OPC: Access to WinCC RT data using OPC DA,
OPC HDA and OPC A&E (connectivity pack)
Extensive range of options and add-ons
SIMATIC ProAgent process diagnostics software
• Process diagnostics software for fast, targeted fault diagnosis
in plants and machines for SIMATIC S7 and SIMATIC HMI
• A standardized diagnostics concept for various SIMATIC
components:
Optimized interaction between STEP 7 engineering tools and
SIMATIC HMI
• Standardized user interface
• Integral component of Totally Integrated Automation (TIA):
Increases productivity, minimizes engineering outlay, reduces
lifecycle costs
4/4
Siemens ST 80 · 2009
• ProAgent
- provides optimum support for plant and machine personnel
in respect of troubleshooting and fault rectification
- increases plant availability
- reduces downtimes
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time
• No special operator know-how is required thanks to clearly
comprehensible indication of the cause of error
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible engineering software
SIMATIC WinCC flexible ES
■ Overview
■ Application
SIMATIC WinCC flexible Micro/Compact/Standard/Advanced
are innovative engineering tools for configuration SIMATIC HMI
devices, the operating component of SIMATIC C7 devices, the
SIMOTION/SINUMERIK Panel PCs, and the PC-based
visualization system WinCC flexible Runtime.
• Integrated family of engineering tools for configuring SIMATIC
HMI Operator Panels, the operating device of SIMATIC C7
units, SIMOTION/SINUMERIK Panel PCs as well as the
PC-based visualization software WinCC flexible Runtime.
• Runs under Windows XP Professional/Windows VISTA
Business, Ultimate
• Current version:
- SIMATIC WinCC flexible 2008 Advanced
- SIMATIC WinCC flexible 2008 Standard
- SIMATIC WinCC flexible 2008 Compact
- SIMATIC WinCC flexible 2008 Micro
■ Benefits
• The integrated configuration software reduces training, maintenance and service overhead and protects the customer’s
investments
• Minimized engineering overhead and reduction of lifecycle
costs thanks to Totally Integrated Automation (TIA)
• Minimized configuration overhead due to reuse of scalable
and dynamizable objects
• Intelligent tools for efficient and simple configuration:
- Wizard for defining the basic structure of the HMI project
- Table-based editors simplify the generation and processing
of similar types of object, e.g. for tags, texts, or alarms.
- Complex configuration tasks such as the definition of paths
of motion or the creation of the fundamental operator
prompting are simplified by means of graphical configuration.
• Comprehensive support of multi-language configurations for
worldwide use
- Selectable views for entering configuration data in several
languages
- System and user-specific text lexicons
- Export/import of language-dependent texts
• Investment protection due to
- Import of the configuration from the configuration tools of the
ProTool family
- Import of static screen contents and tags from WinCC V6.2
Various target systems can be configured depending on the
selected product:
• WinCC flexible Micro
- Micro Panels: OP 73micro, TP 170micro, TP 177micro
• WinCC flexible Compact
- Micro Panels: OP 73micro, TP 170micro, TP 177micro
- Mobile Panels: Mobile Panel 170, Mobile Panel 177
- Basic Panels: KTP 400 Basic, KTP 600 Basic, KTP 1000 Basic, TP 1500 Basic
- 70 series Panels: OP 73, OP 77A, OP 77B
- 170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B,
OP 170B, OP 177B
- 170 series Multi Panels: MP 177
- C7 devices: C7-635 (Touch/Key)
• WinCC flexible Standard
- Micro Panels: OP 73micro, TP 170micro, TP 177micro
- Mobile Panels: Mobile Panel 170, Mobile Panel 177, Mobile
Panel 277
- Basic Panels: KTP 400 Basic, KTP 600 Basic,
KTP 1000 Basic, TP 1500 Basic
- 70 series Panels: OP 73, OP 77A, OP 77B
- 170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B,
OP 170B, OP 177B,
- 270 series Panels: TP 270, TP 277, OP 270, OP 277
- 170 series Multi Panels: MP 177
- 270 series Multi Panels: MP 270B, MP 277
- 370 series Multi Panels: MP 370, MP 377
- C7 devices: C7-635 (Touch/Key), C7-636 (Touch/Key)
• WinCC flexible Advanced
- Micro Panels: OP 73micro, TP 170micro, TP 177micro
- Mobile Panels: Mobile Panel 170, Mobile Panel 177, Mobile
Panel 277
- Basic Panels: KTP 400 Basic, KTP 600 Basic,
KTP 1000 Basic, TP 1500 Basic
- 70 series Panels: OP 73, OP 77A, OP 77B
- 170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B,
OP 170B, OP 177B
- 270 series Panels: TP 270, TP 277, OP 270, OP 277
- 170 series Multi Panels: MP 177
- 270 series Multi Panels: MP 270B, MP 277
- 370 series Multi Panels: MP 370, MP 377
- C7 devices: C7-635 (Touch/Key), C7-636 (Touch/Key)
- Standard PC
- SIMATIC Panel PC: Panel PC IL 70, Panel PC IL 77, Panel PC
477/477B, Panel PC 577/577B, Panel PC 670, Panel
PC 677/677B, Panel PC 870, Panel PC 877
- SIMOTION Panel PC: P012K, P012T, P015K, P015T, PCR,
PCR-Touch
- SINUMERIK Panel PC: HT8, OP08T, OP010, OP012, TP012,
OP015, TP015, OP015A
For configuring panels released after the start of delivery of
WinCC flexible 2008, an HSP (Hardware Support Package) is
required that can be downloaded free of charge via the following
link:
http://www.siemens.com/wincc-flexible-hsp
Siemens ST 80 · 2009
4/5
4
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible engineering software
SIMATIC WinCC flexible ES
■ Design
The engineering tools of the SIMATIC WinCC flexible range are
based on one another. The available editors largely depend on
the respectively configured target systems and their functions. A
more comprehensive engineering tool such as WinCC flexible
Standard also offers the facilities of the smaller engineering
tools, e.g. WinCC flexible Compact or Micro.
Upgrading of a smaller engineering tool to a larger one is possible using a Powerpack. An exception is WinCC flexible Micro.
The scope of functions of the WinCC flexible engineering tools
already includes project support for the Runtime options available for SIMATIC Panels or WinCC flexible Runtime, independent of the RT licenses purchased. Separate licensing is required for the target system in order to use the configured
Runtime options.
4
■ Function
Integration into automation systems
• Integration into SIMATIC STEP 7/SIMOTION
- Management of HMI projects within the SIMATIC Manager
- Shared use of communication settings and process point
definitions, i.e., symbols and messages
- Display of the HMI configuring objects in the SIMATIC
Manager
- Transfer of configuring data via MPI/PROFIBUS/Ethernet
using routing
Configuration interface
• Innovative engineering tools based on the latest SW technology, Microsoft.NET
• Comprehensive and fast access to editors and project data
via Workbench applications
• Adaptive user interface of engineering tools depending on
configured target system
• User-definable user interface settings, e.g., layout, toolbars,
object defaults
Project handling
• Device-independent configuration data can be used on a
variety of target systems without the need for conversion;
the interface adapts to the functional possibilities of the device
currently configured.
• Cross-device utilization of common configuration data (e.g.,
text library) in multi-device projects
• Wizard-assisted definition of basic structure of HMI projects
(e.g., display layout, operator prompting)
Screen editor with extensive options for efficient and fast
screen configuration
• Generation of interconnected screen objects via Drag&Drop,
e.g., tags for the creation of input/output fields with process
interfacing or buttons with screen selection function
• Templates for the definition of global screen objects and functions (comparable with the Slide Master in MS PowerPoint)
• User-friendly editor for the creation of image blocks with
defined external interface from screen objects
• Graphics-based configuration of motion paths
• Layer technology with up to 32 layers
• Tools for the Align, Rotate and Mirror functions
4/6
Siemens ST 80 · 2009
Import/export
• of texts for translation
• of tags, links and messages
• Generation of variable lists for importing from controller programming tools
Tabular editors
• Quick and easy generation and modification of configuration
objects of the same type, e.g., variables, texts or messages,
in tabular editors
• Intelligent defaults, depending on previously configured data,
e.g., automatic upcounting of addresses when generating
consecutive variables
• Modification of properties by means of easy access to Properties dialog without excessive user intervention ("Always on
Top")
• Simultaneous modification of common object properties
Object-based data management with user-friendly search
and edit options
• Cross-reference list with direct access to all objects, e.g. for
editing or selection
• Search for objects in entire project
• Central reassignment of variables
• Text search and replace functions
Project documentation
• Selective project documentation printout or save to file (rtf,
htm, tif, txt)
Libraries for predefined/user-defined configuration objects
• Large number of scalable and dynamizable screen objects
included in scope of delivery
• Size-scalable WMF-format graphics for industrial applications
included in scope of delivery
• Preview function for library objects
• Storage of all engineering objects in library, e.g., blocks and
even entire displays or variables;
picture blocks can be created on a customer- or project-specific basis by combining simple screen objects. Changes to
these picture blocks can be made centrally (block definition).
Language support
• Multilingual project creation (max. 32 languages) in editors
thanks to selectable views
• Automatic translation on basis of system- and user-specific
dictionaries in central text library
• Central management of language-specific texts and graphics
in libraries
• Edit, export and import of texts for translation
• Language-specific graphics
Visual Basic Script support
• IntelliSense function for fast programming of access to
runtime objects
• Simple creation of control sequences in script code;
• Script debugging in Simulator and WinCC flexible Runtime
Graphics-based configuration of operator prompting
• Simple operator prompting concept based on hierarchical
menu tree
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible engineering software
SIMATIC WinCC flexible ES
■ Function (continued)
Test and startup support
• Simulation of HMI projects on engineering PC
• Jump to error cause based on alarm messages in the
Compiler
• Advanced ProSave service tool for all operating systems
supported by WinCC flexible
System requirements
(minimum requirements)
WinCC flexible Engineering
Software
Operating system
Windows XP Professional SP2/SP3
(32-bit),
Windows Vista Business,
Ultimate (32-bit)
Additionally for SIMATIC WinCC
flexible Micro:
Windows XP Home SP2/SP3
Scheduler for the definition of all global tasks
• Configuration of global system functions or time-driven events
Processor
Pentium 4 (or comparable)
processor running at 1.6 GHz or
faster
ChangeControl (option)
• Version management of project versions with rollback
• Logging of configuration changes, e.g., for regulated
industries
Resolution
1024 x 768 or higher
Main memory (RAM)
≥ 1 GB,
≥ 512 MB for WinCC flexible Micro
Default runtime data in engineering tools
• Users and passwords
• Recipe data records
Migration of existing HMI projects
• Complete data transfer in projects for ProTool/Pro RT as well
as 170, 270 and 370 Series control units
• Conversion of configuring data on TP/OP27, e.g. to OP 277,
and on TP/OP37, e.g. to MP 377
• Conversion of OP3 or OP7/OP17 configuring data to OP 73 or
OP 77B/OP 177B
• Transfer of WinCC V6.2 project components (static picture
components and tags only)
Compatibility
• Integrated upward compatibility Further processing of WinCC
flexible configuration data with future versions without loss of
data
• Integrated downward compatibility: Creation of configuration
data for older versions of WinCC flexible engineering tools.
Hard disk (free memory space)1) ≥ 2 GB2)
≥1.2 GB for WinCC flexible
Micro3)
DVD drive
4
for software installation
1)
In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk;
e.g., for the swap file. The following formula has proven itself in the past:
The size of the swap file = 3 x the size of the RAM.
For further information, refer to your Windows documentation
2)
When installing one language. 200 MB are additionally required for each
further language. In the case of different partitions for system and configuration: System partition approx. 700 MB, project partition approx. 1.3 GB.
3)
When installing one language. 80 MB are additionally required for each further language. In the case of different partitions for system and configuration: System partition approx. 600 MB, project partition approx. 600 MB.
Options
SIMATIC WinCC flexible/ChangeControl
WinCC flexible/ChangeControl enables consistent backup of
configuration data. Delivered customer projects, approved reference states or development stages are managed in a database. Changes to project data can be integrated without problem into the version management using new versions. A rollback
is possible at any time.
The history of changes can be verified down to the last detail for
applications requiring interruption-free proof for the complete life
cycle of a product.
Note:
For further information, refer to "WinCC flexible ES options".
Siemens ST 80 · 2009
4/7
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible engineering software
SIMATIC WinCC flexible ES
■ Ordering data
Order No.
WinCC flexible 2008 Advanced D
6AV6 613-0AA51-3CA5
Floating license, on DVD incl.
license key, includes:
D
6AV6 612-0AA51-3CA5
D
6AV6 610-0AA01-3CA8
6AV6 613-6AA01-3AB5
• Native drivers
• Electronic documentation (.pdf)
in German, English, French,
Italian, Spanish, simplified
Chinese, traditional Chinese,
Korean, Japanese
• Engineering software for configuring WinCC flexible Runtime on
basic PCs/Panel PCs as well as
Micro Panels, Basic Panels and
70/170/270/370 series Panels
incl. C7-635/636
4
Order No.
WinCC flexible 2008 Standard
WinCC flexible 2008 Micro
• SW for WinCC flexible/ChangeControl engineering option1)
Floating license, on DVD without
license key, includes:
• Simulation softwarefor WinCC
flexible Runtime as well as Micro
Panels, Basic Panels and
70/170/270/370 series Panels
incl. C7-635/636
• Engineering software for
configuration of Micro Panels
• Native drivers
WinCC flexible/ChangeControl D
for WinCC flexible 2008
Compact/Standard/Advanced 1)3)
• Electronic documentation (.pdf)
in English, German, French,
Italian, Spanish
• Electronic documentation (.pdf)
in German, English, French,
Italian, Spanish, simplified
Chinese, traditional Chinese,
Korean, Japanese
WinCC flexible 2008 Standard
Floating license, option, license
key only
D
6AV6 612-0AA51-3CA5
Floating license, on DVD incl.
license key, includes:
• SW for WinCC flexible/ChangeControl engineering option1)
• Simulation software for Micro
Panels, Basic Panels and
70/170/270/370 series Panels
incl. C7-635/636
• WinCC flexible 2008 Standard D
to 2008 Advanced
6AV6 613-2CD01-3AD5
• WinCC flexible 2008 Compact D
to 2008 Advanced
6AV6 613-2BD01-3AD5
• WinCC flexible 2008 Compact D
to 2008 Standard
6AV6 612-2BC01-3AD5
Software Update Service
Software Update Service
SIMATIC WinCC flexible 2)4)
• Native drivers
• Electronic documentation (.pdf)
in German, English, French,
Italian, Spanish, simplified
Chinese, traditional Chinese,
Korean, Japanese
• WinCC flexible Advanced
D
6AV6 613-0AA00-0AL0
• WinCC flexible Standard
D
6AV6 612-0AA00-0AL0
• WinCC flexible Compact
D
6AV6 611-0AA00-0AL0
D
6AV6 611-3AA51-3CE5
• ProTool to WinCC flexible 2008 D
Standard
6AV6 612-3AA51-3CE5
• ProTool/Pro to WinCC flexible
2008 Advanced
6AV6 613-3AA51-3CE5
Upgrades
D
6AV6 611-0AA51-3CA5
Floating license, on DVD incl.
license key, includes:
• Engineering software for configuring Micro Panels, Basic Panels
and 70/170 series Panels incl.
C7-635
• SW for WinCC flexible/ChangeControl engineering option1)
• Simulation software for Micro
Panels, Basic Panels and
70/170 series Panels incl.
C7-635
D) Supject to export regulations: AL: N and ECCN: 5D992B1
1)
A separate license for WinCC flexible/ChangeControl must be purchased
for each engineering station.
2)
For a period of 12 months and for a fixed price, the customer is automatically provided with all upgrades and service packs for each installed
WinCC flexible engineering system or option. The contract is automatically
extended by a further year unless canceled up to 12 weeks prior to expiration.
3)
The ChangeControl option has not been released for integrated operation
with STEP 7.
4)
Original delivery note or Certificate of License (CoL) from previous WinCC
flexible Micro required
4/8
SIMATIC WinCC flexible Power
Packs
Single license, license key only
• Engineering software for
configuring Micro Panels, Basic
Panels and 70/170/270/370
series Panels incl. C7-635/636
WinCC flexible 2008 Compact
Power Packs
Siemens ST 80 · 2009
SIMATIC ProTool to
SIMATIC WinCC flexible 2008
• ProTool/Lite to WinCC flexible
2008 Compact
D
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible engineering software
SIMATIC WinCC flexible ES
■ Ordering data
Order No.
Order No.
Upgrades (continued)
Versions for China/Taiwan/Korea/Japan (continued)
SIMATIC WinCC flexible
2004/2005/2007
to SIMATIC WinCC flexible 2008
WinCC flexible 2008 ASIA
Advanced (continued)
D
• Upgrade to WinCC flexible
2008 Standard, incl. ChangeControl option1)
D
6AV6 612-0AA51-3CE5
• Simulation softwarefor WinCC
flexible Runtime as well as Micro
Panels, Basic Panels and
70/170/270/370 series Panels
incl. C7-635/636
D
• Upgrade to WinCC flexible
2008 Advanced, incl. Change1)
Control option
6AV6 613-0AA51-3CE5
• Native drivers
• Upgrade to WinCC flexible
2008 Micro4)
6AV6 610-0AA01-3CE8
• Electronic documentation (.pdf)
in German, English, French,
Italian, Spanish, simplified
Chinese, traditional Chinese,
Korean, Japanese
D
SIMATIC WinCC flexible ASIA
2004/2005/2007 to SIMATIC
WinCC flexible ASIA 2008
• Upgrade to WinCC flexible
2008 ASIA Standard, incl.
ChangeControl option1)
• Upgrade to WinCC flexible
2008 ASIA Advanced, incl.
ChangeControl option1)
D
D
6AV6 612-0AA11-3CE5
User Manual
WinCC flexible Communication
• German
6AV6 691-1CA01-3AA0
6AV6613-0AA11-3CE5
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
D
6AV6 691-1CA01-3AE0
6AV6 612-0AA11-3CA5
Floating license, on DVD incl.
license key, includes:
WinCC flexible Micro
User Manual
• German
6AV6 691-1AA01-3AA0
• Engineering software for configuring Micro Panels, Basic Panels
and 70/170/270/370 series
Panels incl. C7-635/636
• English
6AV6 691-1AA01-3AB0
• French
6AV6 691-1AA01-3AC0
• Italian
6AV6 691-1AA01-3AD0
• Simulation software for Micro
Panels, Basic Panels and
70/170/270/370 series Panels
incl. C7-635/636
• Spanish
6AV6 691-1AA01-3AE0
User Manual
WinCC flexible Compact/
Standard/Advanced
• Native drivers
• Electronic documentation (.pdf)
in German, English, French,
Italian, Spanish, simplified
Chinese, traditional Chinese,
Korean, Japanese
WinCC flexible 2008 ASIA
Advanced
4
Documentation (must be ordered separately)
Versions for China/Taiwan/Korea/Japan
WinCC flexible 2008 ASIA
Standard
6AV6 613-0AA11-3CA5
• SW for WinCC flexible/ChangeControl engineering option1)
• Upgrade to WinCC flexible
2008 Compact, incl. ChangeControl option1)
6AV6 611-0AA51-3CE5
D
D
6AV6 613-0AA11-3CA5
Floating license, on DVD incl.
license key, includes:
• Engineering software for configuring WinCC flexible Runtime as
well as Micro Panels, Basic
Panels and 70/170/270/370
series Panels incl. C7-635/636
B) Subject to export regulations: AL: N and ECCN: EAR99S
D) Subject to export regulations: AL: N and ECCN: 5D992B1
• German
6AV6 691-1AB01-3AA0
• English
6AV6 691-1AB01-3AB0
• French
6AV6 691-1AB01-3AC0
• Italian
6AV6 691-1AB01-3AD0
• Spanish
SIMATIC HMI Manual
Collection
6AV6 691-1AB01-3AE0
B
6AV6 691-1SA01-0AX0
Electronic documentation, on
DVD
5 languages (English, French,
German, Italian, Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
1)
A separate license for WinCC flexible/ChangeControl must be purchased
for each engineering station.
2)
Original delivery note or Certificate of License (CoL) from previous WinCC
flexible Micro required
■ More information
Additional information is available in the Internet under:
Note:
http://www.siemens.com/wincc-flexible
Do you a require specific modification or extension to the
products described here? You will find information about the
Open Platform Program for the creation of user-specific functions and controls for WinCC flexible under "Customized
Products".
Siemens ST 80 · 2009
4/9
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible ES options
WinCC flexible /ChangeControl
■ Overview
■ Application
• In machine/special machine construction for project management, e.g. delivered customer versions and their modifications
• For saving of intermediate states during complex new
developments or expansions, with rollback facility
• During work for specific orders as basis for calculating costs
for modifications
• In regulated sectors as proof of state of plants or machines
and any modifications made to them
■ Function
• Integral GUI for management of project versions (version tree
with main line and secondary lines for modified project
versions)
• Comparison function for determination of differences between
two project versions, i.e. between the current version and a
saved version
• Modification log can be activated/deactivated and shows who
carried out modifications, and when/which. Modification
reasons can be entered as comments.
4
• Options for the versioning of configuration data and for tracing
configuration changes (e.g. as verification in regulated
sectors)
• For the engineering tool SIMATIC WinCC flexible Compact/
Standard/Advanced
• One license is required for each configuration computer
■ Benefits
Order No.
WinCC flexible/ChangeControl
for WinCC flexible 2008
Compact/Standard/Advanced1)
Floating License, option,
license key only
D
6AV6 613-6AA01-3AB5
D) Subject to export regulations: AL: N and ECCN: 5D992B1
• Consistent backup of configuration data
- Delivered versions, approved reference states or development stages are managed in a database.
- Changes to project data can be integrated without problem
into the version management using new versions. A rollback
is possible at any time.
• Tracing of configuration changes
- The history of changes can be verified down to the last detail
for applications requiring interruption-free proof for the
complete life cycle of a product.
4/10
■ Ordering data
Siemens ST 80 · 2009
1)
The ChangeControl option has not been released for integrated
operation with STEP 7.
■ More information
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for WinCC
flexible.
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible runtime software
SIMATIC WinCC flexible RT
■ Overview
■ Application
SIMATIC WinCC flexible Runtime is the high-performance visualization software for simple visualization tasks at machine level.
It can be used as a single-user solution for all automation applications in manufacturing automation, process automation and
building services automation.
• PC-based visualization software for single-user systems
directly at the machine
- Runs under Windows XP Professional and Windows Vista
Business/Ultimate
- current version: SIMATIC WinCC flexible 2008 Runtime with
128, 512, 2048 or 4096 PowerTags
• SIMATIC WinCC flexible Runtime is configured with the
SIMATIC WinCC flexible Advanced configuration software.
■ Benefits
• Optimum price/performance ratio thanks to individually
scalable system functionality
• Functions for all visualization tasks:
Operator functions, graphical and trend displays, signaling
system, log system, archiving (option), recipe management
(option), Audit Trail (option), process fault diagnostics (option)
• Flexible runtime functionality thanks to Visual Basic scripts
• Innovative service concepts with remote operation, diagnostics and administration via intranet and Internet as well as
e-mail communication to increase availability (option)
• Support for simple distributed automation solutions based on
TCP/IP networks at the machine level (option)
SIMATIC WinCC flexible Runtime can be used in combination
with the following operator panels:
• SIMATIC Panel PCs
- PC IL 70/77
- Microbox 420
- Panel PC 477
- Panel PC 577
- Panel PC 670/677
- Panel PC 870/877
• SIMOTION Panel PCs
- P012, P015
- PCR, PCR-Touch
• SINUMERIK Panel PCs
- HT8; OP08T
- OP010, OP012, OP015
- TP012, TP015, OP015A
• Standard PCs with resolutions (W x H in pixels) of:
- 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024,
1600 x 1200
■ Design
SIMATIC WinCC flexible Runtime is available as a software
package with 128, 512, 2048 or 4096 PowerTags. The term
PowerTags is used exclusively to identify process variables and
range pointers that have a process link to the controller.
Variables without process link, constant limit values of variables,
and messages (up to 4000 bit-triggered messages) are also
available for additional system performance.
The range of functions of WinCC flexible Runtime includes the
centralized HMI components for visualizing and reporting, and
it can be expanded to suit requirements and costs by using
optional packages.
SIMATIC WinCC flexible Runtime is configured with the SIMATIC
WinCC flexible Advanced configuration software.
Siemens ST 80 · 2009
4/11
4
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible runtime software
SIMATIC WinCC flexible RT
■ Function
Visualization via Windows-compliant user interface
4
made up of parameterizable screen objects and image blocks
created on a project-specific basis:
• Numeric and alphanumeric input/output fields
• Static text and graphic display plus vector graphics
• Dynamizable graphics from HMI symbol library
• Bar graph, trend curve graph with scroll and zoom function as
well as read line
• Signal-specific text and graphic lists
• Buttons and switches for operator-process communication
• Editing fields for process values (signals)
• Analog display, slider as example for further screen objects
• Project-specific image blocks created from system basic
objects
• Graphic displays for various standard graphic formats, e.g.,
bitmaps, .jpg, .wmf
Alarms and messages
• Discrete alarms and analog messages as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7
• Freely-definable message classes for definition of acknowledgment response and display of message events
Archiving of alarms and process values 1)
• Archiving in files (e.g. CSV file) and ODBC databases
• Online evaluation of process value archives and alarm logs
• Evaluation of process value archives and alarm logs using
standard Microsoft tools such as Excel
Recipes 1)
• Generation of data records for machine or production data
• Display or entry of data records via a configurable screen object or via process images when distributed within the project
• Transmission of data records from or to the PLC
• Import/export for data records from/to CSV files
Documentation of process data, alarm events and recipes
• Time- or event-driven report output
• User-definable layout
Flexible expansion of system function using Visual Basic
script
Language support for multilingual projects
• Up to 16 online languages (incl. Asian and Cyrillic)
• Language-dependent texts and graphics
• Language selection during runtime
4/12
Siemens ST 80 · 2009
User-oriented access protection according to requirements
of regulated sectors
• Authentication with user ID and password
• User-group-specific rights
• Central system-wide user administration based on SIMATIC
Logon 1)
• Monitoring of changes by operators in runtime operation1)
• Recording of operator actions in an Audit Trail1)
PLC link for a wide variety of PLCs on-board
• Simultaneous connection using several protocols: OPC Client
or SIMATIC HMI HTTP protocol are additive, i.e. can be used
in conjunction with other PLC links
• Communication via native drivers and standard OPC channel
Open communication between HMI systems and with
higher-level systems1)
• OPC server
• [email protected] for communication between HMI systems
based on Ethernet networks, or via the intranet/Internet:
• Read and write access to variables;
WinCC flexible Runtime or SIMATIC Panels make data
(variables) available to other SIMATIC HMI systems or Office
applications.
• A SIMATIC HMI system can be used to control or monitor
another system remotely;
entry level for client/server configurations for distributed
operator stations or for solutions with headend or control
room.
[email protected] for remote control, diagnostics and
administration via intranet and Internet1)
• Display and control of process images on remote PC or Panel
• Sending of e-mails on demand or event-driven
• System diagnostics visualized via device-specific HTML
pages
1)
Option for SIMATIC WinCC flexible Runtime; separate runtime licenses
must be purchased
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible runtime software
SIMATIC WinCC flexible RT
■ Function (continued)
Options (continued)
System requirements
WinCC flexible Runtime
Operating system
Windows XP Professional SP2/SP3
(32-bit)
Windows XP embedded 1)
Windows Vista Business (32-bit)
Windows Vista Ultimate (32-bit)
Processor4)
• Minimum
Windows XP: 300 MHz
Windows Vista: 1 GHz
• Recommended
Windows XP: ≥ Pentium III,
500 MHz
Windows Vista: ≥ 1 GHz
Graphics
• Minimum
SVGA
• Resolution
640 x 480 to 1600 x 1200
RAM2)
• Minimum
Windows XP: 128 MB
Windows Vista: 1GB
• Recommended
Windows XP: ≥ 512 MB
Windows Vista: ≥ 1GB
Hard disk (free memory space)3) ≥ 250 MB
1)
Only for enabled platforms (e.g. Panel PC 477). You can get information
from your Siemens contact.
2)
RAM requirements are determined primarily by the size of the graphics
used.
3)
Without taking archives into account.
In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk; e.g., for the swap file. The following formula has
proven itself in the past: The size of the swap file = 3 x the size of the RAM.
For further information, refer to your Windows documentation
4)
More powerful systems (Pentium 4 and higher) may be required in order to
use options
Options
SIMATIC WinCC flexible /Archives
• Archiving of alarms and process values
- Archiving in files (e.g. CSV file) or ODBC databases
- Online evaluation of process value archives and alarm logs
- Evaluation of process value archives and alarm logs using
standard Microsoft tools such as Excel
SIMATIC WinCC flexible /Recipes
• Generation and management of data records for machine or
production data
- Display or entry of data records via a configurable screen
object or via process images when distributed within the
project
- Transmission of data records from or to the PLC
- Import/export for data records from/to CSV files
SIMATIC WinCC flexible /Audit
• Recording of operator actions in an Audit Trail
• The ChangeControl option supports users in respect of plant
validation.
• Can be checked using security mechanism if changes are
made subsequently.
• Simplified compliance with GMP directives
SIMATIC WinCC flexible /SIMATIC Logon
• Central plant-wide user management
• Set up or block users plant-wide and across applications
• The central user management with SIMATIC Logon uses the
Windows mechanisms
SIMATIC WinCC flexible /[email protected]
• Flexible solution for access to process data from any location
• Communication between different SIMATIC HMI systems
SIMATIC WinCC flexible /[email protected]
• Remote maintenance and servicing of machines and plant via
Internet/intranet
• Event-driven sending of e-mails
• System diagnostics visualized via device-specific html pages
SIMATIC WinCC flexible /OPC Server
• Incorporation of automation components from different
vendors into a single automation concept
• Communication for data exchange between HMI systems
and/or higher-level control system
• Communication with applications from different vendors, e.g.
MES, ERP or applications in the office sector
Note:
For further information, refer to "SIMATIC WinCC flexible RT
options".
SIMATIC WinCC flexible /ProAgent
• Precise and rapid process fault diagnostics in plant and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various SIMATIC
components
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time
Note:
For further information, refer to "SIMATIC ProAgent process
diagnosis software".
Siemens ST 80 · 2009
4/13
4
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible runtime software
SIMATIC WinCC flexible RT
■ Integration
SIMATIC WinCC flexible Runtime supports linking to:
Protocol
PC interfaces
SIMATIC S5 via AS511 (TTY)
COM1/COM213)
S5-90U
S5-90U
PC interfaces
SIMATIC 545/555 with CP 5434
CP 55122)
CP 5611 A22)
SIMOTION8)
S5-100U (CPU 100, 102, 103)
SINUMERIK9)
S5-115U (CPU 941, 942, 943, 944,
945)
PLCs from other manufacturers
S5-135U (CPU 928A, 928B)
Allen Bradley (DF1/DH485)
COM1/COM2
S5-155U (CPU 946/947, 948)
Allen Bradley (Ethernet)
CP 16127)
1)
SIMATIC S5 via PROFIBUS DP
S5-95U/L2-DP master
4
Protocol
SIMATIC 505 via PROFIBUS DP
S5-115U (CPU 941, 942, 943, 944,
945)
CP 55122)
CP 5611 A22)
S5-135U (CPU 928A, 928B)
S5-155U (CPU 946/947, 948)
SIMATIC S7 via PPI
CP 55122)
CP 5611 A22)
CP 56211)
CP 5613 A2
CP 5614 A2
PC/PPI adapter3)
S7-200
SIMATIC S7 via MPI
S7-200 (except CPU 212)4)
S7-300
S7-400
WinAC Basis (V3.0 and higher)
WinAC RTX
CP 55122)
CP 5611 A22)
CP 56211)
CP 5613 A2
CP 5614 A2
PC/MPI adapter6)
PC adapter USB6)
Teleservice V6.1
SIMATIC S7 via PROFIBUS DP 5)
S7-215 4)
S7-300 CPUs with integr.
PROFIBUS interface
S7-300 with CP 342-5
CP 55122)
CP 5611 A22)
CP 56211)
CP 5613 A2
CP 5614 A2
GE Fanuc (SNP/SNPX)
COM1/COM2
LG GLOFA GM
COM1/COM2
Mitsubishi (FX/MP4)
COM1/COM2
Modicon (Modbus)
COM1/COM2
Modicon (Modbus TCP/IP)
CP 16127)
OMRON (Link/Multilink)
COM1/COM2
OPC (Client + Server)10)12)
Data Access V2.0 + V1.1 (COM) /
V1.0 (XML) client only
CP 16127)
HTTP communication for data
CP 16127)
exchange between SIMATIC HMI
(client + server)11)12)
1)
WinCC flexible Runtime is passive (DP slave); the function block required
for the link is included in the scope of delivery of WinCC flexible
2)
For Microbox 420/427 and Panel PC 477/677 via internal MPI/DP interface
3)
Only point-to-point to S7-200; no configuration download, operating systems: Windows 2000/XP;
Order number: 6ES7 901-3CB30-0AX0
4)
Constraint with regard to baud rate for S7-200; see Catalog ST 70
5)
WinCC flexible RT is active; communication with S7 functions
6)
Only point-to-point to S7-300/-400;
No configuration download, operating systems: Windows 2000/XP;
Order number: 6ES7 972-0CA23-0XA0 (COM) or 6ES7 972-0CB20-0XA0
(USB)
7)
For MicroBox 420 and Panel PC 477/577/677/877 via internal Ethernet
interface
8)
S7-400 CPUs with integr.
PROFIBUS interface
For further information, see Catalog PM 10
9)
"SINUMERIK HMI copy license OA" option required; for further information,
see Catalog NC 60
S7-400 with CP 443-5 or IM 467
10)
OPC Client is included in scope of delivery, the "WinCC flexible/OPC
Server for WinCC flexible Runtime" license is required for the OPC Server
option
WinAC RTX
11)
"WinCC flexible/[email protected] for WinCC flexible Runtime" license required
SIMATIC S7 via Ethernet (TCP/IP)
12) OPC
WinAC Basis (V3.0 and higher)
S7-200 with CP 243-1
S7-300 CPUs with integral Ethernet interface
16127)
CP
CP 1613 A2
S7-400 with CP 443-1
WinAC Basis (V3.0 and higher)
WinAC RTX
SIMATIC S7 via integrated interface
Internal system interface
WinAC RTX
SIMATIC 505 NITP
4/14
Siemens ST 80 · 2009
PC cable with integrated level converter RS 232/TTY; Order number:
6ES5 734-1BD20
In parallel with each and every PLC link, WinCC flexible Runtime
supports the use of the OPC Client channel; this enables, for
example, connection to an SNMP OPC Server for the purpose of
visualizing the data stored there. The SNMP OPC Server provides a means of monitoring network components of any type
(e.g. switches) which support the SNMP protocol. For further information, see Catalog IK PI.
S7-400 CPUs with integral Ethernet interface
SIMATIC 500/505 RS 232/RS 422
13) Via
Application note
S7-300 with CP 343-1
WinAC Basis (V2.0 and higher)
and HTTP communication are additive, i.e. can be used in conjunction with the PLC links listed above
COM1/COM2
Note:
For further information, see "HMI devices/System interfaces"
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible runtime software
SIMATIC WinCC flexible RT
■ Integration (continued)
Higher level visualization system
OPC Client
Industrial Ethernet
On-site visualization
OPC Server
OPC Server
4
OPC Client
PROFIBUS
SIMATIC S7-300
SIMATIC S7-400
3rd party
OPC Server
G_ST80_XX_00077
Non-Siemens
PLCs
SIMATIC WinCC flexible Runtime application example
■ Technical specifications
Type
SIMATIC WinCC flexible RT
The specifications are maximum
values
Screens
500
• Fields per screen
400
• Variables per screen
400
• Static text
30.000
• Graphics objects
2.000
Type
Archives
SIMATIC WinCC flexible RT
4)
100
• Archivable data
Process data,
messages
• Max. number of entries per archive (incl. sequence archive)
500.000
• Archive types
Short-term archive, sequence
archive (max. 400 per archive)
• Data storage format
CSV (Comma Separated Variable),
RDB (Runtime Data Base),
interface to ODBC database (database not included in scope of
delivery)
• Complex objects per display (e.g. 40
bars)
• Trends
800
• Graphics lists 1)
500
Recipes4)
1,000
• Text lists 1)
500
• Elements per recipe
2,000 3)
• Number of entries in symbol tables
3.500
• Data records per recipe
5,000 2)
Variables
4.0963)
Messages bit-triggered / analog
4.000 / 500
• Message text (number of charac- 80
ters)
• Number of process values per
message
8
• Size of message buffer
1.024
• Pending message events
500
1)
Together only 500 text and graphics lists
2)
Dependent on memory medium used
3)
Dependent on number of licensed PowerTags
4)
Options for SIMATIC WinCC flexible Runtime
Password protection
• User rights
32
• Number of user groups
50
Visual Basic scripts
200
Online languages, max.
16
Siemens ST 80 · 2009
4/15
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible runtime software
SIMATIC WinCC flexible RT
■ Technical specifications (continued)
Type
SIMATIC WinCC flexible RT
Type
SIMATIC WinCC flexible RT
Communication
Communication (continued)
SIMATIC S7 MPI interface/
PROFIBUS DP interface
SIMATIC S5
PROFIBUS DP interface
• Number of connectable stations, Depending on the scope of the
max.
configuration (communication)
from the point of view of WinCC
flexible Runtime, as many as 8 connections are possible
• Number of connectable stations, 1 from viewpoint of WinCC flexible
max.
Runtime
Multi-protocol operation
Yes, OPC Client or SIMATIC HMI
HTTP protocol are additive, i.e. can
be used in conjunction with other
PLC links
SIMATIC S7 PPI interface
• Number of connectable stations, 1 from viewpoint of WinCC flexible
max.
Runtime
4
■ Ordering data
Order No.
Order No.
Upgrades (continued)
SIMATIC WinCC flexible 2008
Runtime
SIMATIC WinCC flexible
2004/2005/2007 Runtime to
SIMATIC WinCC flexible 2008
Runtime
for PC systems; incl. SW for PC
systems options1) Single license,
on CD-ROM incl. licensing, for:
• 128 PowerTags (RT 128)
D
6AV6 613-1BA51-3CA0
• 512 PowerTags (RT 512)
D
6AV6 613-1DA51-3CA0
• 2048 PowerTags (RT 2048)
D
6AV6 613-1FA51-3CA0
• 4096 PowerTags (RT 4096)
D
6AV6 613-1GA51-3CA0
• Upgrade to SIMATIC WinCC
flexible Runtime 2008
PowerTags incl. Runtime
Options for:
D
6AV6 613-1XA51-3CE0
D
• Upgrade of the SIMATIC
WinCC flexible
Panel options:
- WinCC flexible /[email protected]
for SIMATIC Panel
- WinCC flexible /[email protected]
for SIMATIC Panel
- WinCC flexible /OPC server for
SIMATIC Multi Panel
- WinCC flexible /ProAgent for
SIMATIC Multi Panel
- WinCC flexible /Audit for
SIMATIC Panel
6AV6 618-7XX01-3AF0
- WinCC flexible /[email protected]
Power Packs
- WinCC flexible /[email protected]
SIMATIC WinCC flexible 2008
Runtime
- WinCC flexible /OPC server
Single license, only license key
for PowerTags, from
- WinCC flexible /Recipes
- WinCC flexible /Archives
- WinCC flexible /ProAgent
• 128 to 512 PowerTags
D
6AV6 613-4BD01-3AD0
• 128 to 2048 PowerTags
D
6AV6 613-4BF01-3AD0
• 512 to 2048 PowerTags
D
6AV6 613-4DF01-3AD0
• 128 to 4096 PowerTags
D
6AV6 613-4BG01-3AD0
• 512 to 4096 PowerTags
D
6AV6 613-4DG01-3AD0
• 2048 to 4096 PowerTags
D
6AV6 613-4FG01-3AD0
• ProTool/Pro Runtime
128 PowerTags to
WinCC flexible 2008 Runtime
128 PowerTags2)
D
6AV6 613-3BB51-3CE0
• ProTool/Pro Runtime
256 PowerTags to
WinCC flexible 2008 Runtime
512 PowerTags2)
D
6AV6 613-3CD51-3CE0
User Manual
WinCC flexible Runtime
• German
6AV6 691-1BA01-3AA0
6AV6 613-3DD51-3CE0
• English
6AV6 691-1BA01-3AB0
• French
6AV6 691-1BA01-3AC0
• Italian
6AV6 691-1BA01-3AD0
• Spanish
6AV6 691-1BA01-3AE0
Upgrades
SIMATIC ProTool/Pro RT to
SIMATIC WinCC flexible 2008
Documentation (must be ordered separately)
• ProTool/Pro Runtime
512 PowerTags to
WinCC flexible 2008 Runtime
512 PowerTags2)
D
• ProTool/Pro Runtime
2048 PowerTags to
WinCC flexible 2008 Runtime
2048 PowerTags2)
D
6AV6 613-3FF51-3CE0
D) Subject to export regulations: AL: N and ECCN: 5D992B1
4/16
- WinCC flexible /Audit
Siemens ST 80 · 2009
User Manual
WinCC flexible Communication
• German
6AV6 691-1CA01-3AA0
• English
6AV6 691-1CA01-3AB0
• French
6AV6 691-1CA01-3AC0
• Italian
6AV6 691-1CA01-3AD0
• Spanish
6AV6 691-1CA01-3AE0
1)
Runtime licenses for WinCC flexible Runtime options must be purchased
separately for each target system.
2)
each including a single license WinCC flexible /Archives and WinCC
flexible /Recipes
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible runtime software
SIMATIC WinCC flexible RT
■ Ordering data
Order No.
Documentation (must be ordered separately) (continued)
SIMATIC HMI Manual
Collection
B
6AV6 691-1SA01-0AX0
Electronic documentation, on
DVD
5 languages (English, French,
German, Italian, Spanish);
contains: all currently available
user manuals, manuals and communication manuals for SIMATIC
HMI
Communication via Industrial Ethernet
6GK1 161-3AA01
CP 1613-A2
PCI card (32 bit) for connecting a
PG/PC to Industrial Ethernet
(communications software must
be ordered separately)
SIMATIC Net Edition 2007 IE
S7-1613
Software for S7 and open communication, incl. PG/OP communication, OPC server and NCM PC; up
to 120 connections, runtime software, software and electronic
manual on CD-ROM, license key
on a USB stick, Class A, for 32-bit
Windows XP Professional SP1, 2;
Windows 2003 Server SP1, R2,
SP2; Windows Vista Business/
Ultimate for CP 1613/CP 1613 A2/
CP 1623; German/English
6GK1 716-1CB70-3AA0
• Software Update Service for one D
6GK1 716-1CB00-3AL0
year, with automatic extension;
requirement: Current software
version
• Upgrade S7-1613 from V6.4 to D
S7-1613 Edition 2007
6GK1 716-1CB00-3AE0
• Upgrade S7-1613 from V6.0,
V6.1, V6.2 or V6.3 to S7-1613
Edition 2007
6GK1 716-1CB00-3AE1
D
Software for S7 communication,
incl. PG and FDL protocol, OPC
server and NCM PC; runtime
software, software and electronic
manual on a USB stick, license
key on diskette, Class A, for 32-bit
Windows XP Professional SP1, 2;
Windows 2003 Server SP1, R2,
SP2; Windows Vista Business/
Ultimate for CP 5613,
CP 5613 A2, CP5613 FO,
CP 5614, CP5614 A2;
German/English
• Single license for 1 installation
6GK1 713-5CB70-3AA0
• Software Update Service for one
year, with automatic extension;
requirement: Current software
version
6GK1 713-5CB00-3AL0
• Upgrade S7-5613 from V6.4 to D
S7-5613 Edition 2007
6GK1 713-5CB00-3AE0
• Upgrade S7-5613 from V6.0,
V6.1, V6.2 or V6.3 to S7-5613
Edition 2007
6GK1 713-5CB00-3AE1
D
6GK1 551-2AA00
CP 5611-A2
6GK1 561-3AA01
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications software must be ordered
separately).
A
6GK1 561-1AM01
T
6GK1 562-1AA00
Comprising CP 5611 A2 (32-bit)
and MPI cable, 5 m
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or MPI
PC/PPI adapter
6GK1 561-4AA01
6GK1 561-1AA01
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communications software included in
WinCC flexible basic package)
CP 5621
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications software must be ordered
separately).
4
PCMCIA card (32-bit CARDBUS)
for connecting a PG/Notebook to
PROFIBUS or MPI (communications software included in WinCC
flexible).
CP 5611 MPI
Communication via PROFIBUS
CP 5614-A2
SIMATIC Net Edition 2007 PB
S7-5613
CP 5512
• Single license for 1 installation D
CP 5613-A2
Order No.
Communication via PROFIBUS (continued)
6ES7 901-3CB30-0XA0
RS 232, 9-pin; male with
RS 232/PPI converter, max. 19.2
kbit/s
PC/MPI adapter
6ES7 972-0CA23-0XA0
RS 232, 9-pin; male with
RS 232/MPI converter
PC adapter USB
6ES7 972-0CB20-0XA0
For use with Windows 2000/XP
A) Subject to export regulations: AL: N and ECCN: EAR99H
D) Subject to export regulations: AL: N and ECCN: 5D992B1
B) Subject to export regulations: AL: N and ECCN: EAR99S
T) Subject to export regulations: AL: 5A002A1A2 and ECCN: 5A002A1A2
■ More information
Additional information is available in the Internet under:
Note:
http://www.siemens.com/wincc-flexible
Do you need a specific modification or option for the products
described here? Then look up "customer-specific products",
where you will find information about the Open Platform Program
for the creation of user-specific functions and controls for WinCC
flexible.
Siemens ST 80 · 2009
4/17
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /Archives
■ Overview
■ Application
•
•
•
•
•
•
Further use of archives for evaluation and long-term archiving
Record of repeated fault states
Optimization of maintenance cycles
Ensured quality standards
Control of quality as well as production capacity utilization
Documentation of process sequence
■ Function
4
• Option for SIMATIC WinCC flexible Runtime for archiving
process values and messages
• Archiving of process values and messages supports the
acquisition and processing of process data from an industrial
plant or machine. Evaluation of the archived process data
provides information about the operating states of the plant or
machine
• One license is required per operator station (no license is
required for Simatic Panels/Multi Panels)
■ Benefits
• Message and process value archives permit foresighted diagnostics which prevents downtimes
• Early detection of danger or fault states
• Increase in product quality and productivity thanks to regular
evaluation of process value and message archives
4/18
Siemens ST 80 · 2009
• Time-controlled as well as manual or process-controlled
swapping out of process data and messages for long-term
archiving
• During runtime, swapped out data are read in and selectively
analyzed using WinCC flexible Runtime
- Presentation and evaluation of archived process data based
on a configurable trend display. Reading of the values is
facilitated by a read line.
- Presentation and evaluation of archived alarms based on a
configurable alarm view.
- User-friendly navigation in the archives
• External evaluation of the archives using MS standard tools
• Various archive types are supported: sequence and shortterm archives
• Archiving of process values and messages on external,
Windows-supported storage media
- CSV files
- RDB files
- ODBC databases (e.g. MS Access)
• Power standard functions permit user-friendly and flexible
utilization of the archives
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /Archives
■ Technical specifications
■ More information
Type
WinCC flexible /Archives
Note:
The specifications are maximum
values
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for WinCC
flexible.
Execution platform
SIMATIC WinCC flexible Runtime
Archives
100
• Archivable data
Process values, messages
• Cyclical trigger for archiving pro- 1 s
cess values (variables)
• Max. number of entries per archive (incl. sequence archive)
500.0001)
• Archive types
• Circulating archive
• Sequence archive (max. 400
per archive)
1)
4
CSV (Comma Separated
Variable),
RDB (Runtime Data Base) and
interface to ODBC database
(database not included in scope of
delivery)
• Data storage format
Dependent on memory medium used
■ Ordering data
Order No.
D
WinCC flexible/Archives for
WinCC flexible 2008 Runtime1)
6AV6 618-7ED01-3AB0
Single License, license key only
WinCC flexible/Archives+
Recipes for WinCC flexible
2008 Runtime1)
D
6AV6 618-7GD01-3AB0
Single License for each option,
license key only
D) Subject to export regulations: AL: N and ECCN: 5D992B1
1)
One license is required for each operator station.
A license is not required for the engineering system for configuring the
runtime option.
Siemens ST 80 · 2009
4/19
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /Recipes
■ Overview
■ Application
• Assignment of plant/machine parameters in the production
industry
• Batch-oriented production, e.g. in the food or plastics industry
■ Function
4
• Option for SIMATIC WinCC flexible Runtime for managing data
records in recipes that contain related machine or
production data
• The data in a data set can be transferred, for example, from
the control unit to the PLC to switch production to a different
product variant
• One license is required per operator station (no license is
required for SIMATIC Panels/Multi Panels)
■ Benefits
• Generation and management of machine parameters and production data on the basis of data sets, and exchange with the
automation equipment, e.g. with the machine
• Clear tabular representation of data elements with support of
a configurable graphic object, or representation in technical
relationships for several process graphics
• Simple operator prompting using standard functions
• Export/import of data sets for further processing with other
tools (e.g. MS Excel)
4/20
Siemens ST 80 · 2009
• Input of data sets (e.g. operating parameters for a machine,
production data for a plastics processing machine) in WinCC
flexible Runtime, their storage, and passing on to the PLC
• Display and input of data sets using a configurable graphics
object, or distributed among several process displays within
the project
• Data set elements are coupled to the process using direct
linking of the variables
• Transmission of data records from or to the PLC
• Powerful interfaces permit synchronized exchange of data
with the PLC
• Saving of data sets on local media or on remote data servers
via networks
• Import/export of data sets as CSV files
• Logging of data sets, e.g. as batch report/shift report
• Convenient and flexible management of data sets using
powerful standard functions
WinCC flexible recipes and the associated data sets are conveniently created using a separate editor in the WinCC flexible
Advanced engineering tool, and assigned default data. A configurable table object is used to display the data during runtime.
Furthermore, the individual data set elements can also be
directly output for several process displays on the basis of standard input/output boxes. The data can therefore be clearly
presented for the operator in technological layers.
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /Recipes
■ Technical specifications
■ More information
Type
WinCC flexible/Recipes
Note:
The specifications are maximum
values
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for WinCC
flexible.
Execution platform
SIMATIC WinCC flexible Runtime
Recipes
1000
• Entries per recipe
20001)
• Data records per recipe
50002)
• User data length in bytes per
data record
8000 KB2)
1)
Dependent on number of licensed PowerTags
2)
Dependent on memory medium used
■ Ordering data
4
Order No.
D
WinCC flexible/Recipes for
WinCC flexible 2008 Runtime1)
6AV6 618-7FD01-3AB0
Single License, license key only
WinCC flexible/Archives+
Recipes for WinCC flexible
2008 Runtime1)
D
6AV6 618-7GD01-3AB0
Single License for each option,
license key only
D) Subject to export regulations: AL: N and ECCN: 5D992B1
1)
One license is required for each operator station.
A license is not required for the engineering system for configuring the
runtime option.
Siemens ST 80 · 2009
4/21
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /Audit
■ Overview
■ Benefits
• Audit supports the user in meeting special quality requirements, e.g.,
- Production plant requiring validation according to 21 CFR
Part 11 FDA2)
- In respect of traceability according to EU 175/20023)
• Entries in the audit trail are allocated to individual users. This
ensures that responsibilities can be clearly identified
• The audit trail, stored as a CSV file1), can be checked via a
security mechanism to find out if subsequent changes have
been made
• For particularly important user actions, e.g., starting production or loading new recipes, electronic signatures and comments can be configured and then called up and logged
during runtime
• Restrictions:
- WinCC flexible/Audit cannot be used in combination with
Asiatic character sets on panels
4
• Option for SIMATIC WinCC flexible Runtime as well as
SIMATIC Panels for recording operations in an audit trail, and
electronic signature
• The audit trail features a safety mechanism that indicates
subsequent manipulation.
• An easy-to-use configuration option included as standard in
WinCC flexible enables you to set:
- The operator actions to be recorded in the audit trail during
runtime
- The important operator actions requiring electronic
signature/comments during runtime
• The audit option combined with the WinCC flexible ES
ChangeControl option supports the user with plant validation
• Available for the following SIMATIC HMI systems: TP/OP270,
TP/OP277, MP 270B, MP 277, MP 370, MP 377, WinCC
flexible Runtime
• A license is required for every operator control unit
(panel or PC)
1)
CSV Comma Separated Values
2)
The FDA (Food and Drug Administration) is the American public health
body
3)
21 CFR Part 11- law on plant validation
■ Technical specifications
Type
WinCC flexible/Audit
Archive for Audit Trail use on the
Panel
• Plug-in flash memory card on the
panel
• In the higher-level PC (memory
medium) connected to the panel
via Ethernet
Archive for Audit Trail use of
WinCC flexible Runtime
On the PC (storage medium)
Execution platform
SIMATIC Panels
Mobile Panel 277, TP/OP 270,
TP/OP 277
SIMATIC Multi Panels
MP 270B, MP 277, MP 370,
MP 377
PCs
SIMATIC WinCC flexible Runtime
■ Ordering data
Order No.
D
WinCC flexible/Audit for
SIMATIC Panel
Single License, license key only
6AV6 618-7HB01-3AB0
WinCC flexible/Audit for WinCC D
flexible Runtime 2008
Single License, license key only
6AV6 618-7HD01-3AB0
D) Subject to export regulations: AL: N and ECCN: 5D992B1
■ More information
Note:
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for WinCC
flexible.
4/22
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /SIMATIC Logon
■ Overview
■ Design
SIMATIC Logon and SIMATIC Logon Remote Access are
installed on a central station.
The following WinCC flexible stations are connected to the
central station via Ethernet network:
• PCs with WinCC flexible Runtime
• SIMATIC Panels from the 170 series or higher (panels with
Ethernet interface)
Licensing
The following licenses are required:
• SIMATIC Logon basic license
• SIMATIC Logon Remote Access license (3-pack license
10-pack license); more than one SIMATIC Logon Remote
Access license can be installed.
• Option for connecting PCs with SIMATIC WinCC flexible
Runtime and SIMATIC Panels to central user administration.
• Creates user administration on a central computer to which
one or more WinCC flexible stations can be connected over
Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
• SIMATIC Logon for WinCC flexible supports the user in combination with the /Audit and /ChangeControl options in
meeting requirements in accordance with FDA 21 CFR Part 11
and EU178.
• Licensing:
SIMATIC Logon (basic license) and SIMATIC Logon Remote
Access (3-pack license) for connection of 3 WinCC flexible
stations to a central user administration. Additional stations
can be connected by using further SIMATIC Logon Remote
Access licenses (3-pack/10-pack).
■ Benefits
• Centralized configuration on one PC of all access authorizations of a distributed system avoids unnecessary travel times.
Time-consuming multiple configurations for each individual
local station become unnecessary. Accordingly, changes of
user can be easily configured from a central location
• All access data apply throughout the plant on every connected station. Additional access data on local subsystems is
no longer necessary.
The number of connectable stations depends on the SIMATIC
Logon Remote Access licenses used. This number is the total of
the connections provided by the individual licenses. As an
example: Two installed licenses for 10 enable the connection of
20 stations to the central station.
■ Function
Configuration
In the first step, the following data must be saved in the user
administration of WinCC flexible on every WinCC flexible station
in the plant:
• Required user groups with associated user privileges
• IP address, port number, Windows domain of the central
station on which the central user administration is stored.
All user groups are configured with the same names in the
central user administration. All users are created here, and have
automatic access to the connected WinCC flexible stations in
accordance with the relevant user group.
If the connection fails between the central station with SIMATIC
Logon and a WinCC flexible station, the operation is handled
through an "emergency user" which must first be preconfigured
locally.
Intervals for password aging and regulations for the structure of
a password are defined according to the configuration on the
central station and then also apply to all decentrally connected
WinCC flexible stations or the respective users.
Siemens ST 80 · 2009
4/23
4
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /SIMATIC Logon
■ Technical specifications
Type
■ More information
SIMATIC Logon for WinCC
flexible
Execution platform
SIMATIC Panels
Mobile Panel 177 PN; Mobile Panel
277, TP/OP 177B PN/DP,
TP/OP 277
SIMATIC Multi Panels
MP 177, MP 277, MP 377
PCs
WinCC flexible Runtime
■ Ordering data
SIMATIC Logon V1.4.1
4
Order No.
6ES7 658-7BX41-2YA0
Basic license;
single license for 1 installation,
7 languages (German, English,
Spanish, Italian, Chinese,
Japanese);
type of delivery:
License Key Disk, Certificate of
License, Terms and Conditions
SIMATIC Logon Remote Access
for WinCC flexible (3 Clients)
6ES7 658-7BA00-2YB0
Remote access for 3 WinCC
flexible 2008 clients;
single license for 1 installation;
type of delivery:
License Key Disk, Certificate of
License, Terms and Conditions
SIMATIC Logon Remote Access
for WinCC flexible (10 clients)
Remote access for 10 WinCC
flexible 2008 clients;
single license for 1 installation;
type of delivery:
License Key Disk, Certificate of
License, Terms and Conditions
4/24
Siemens ST 80 · 2009
6ES7 658-7BB00-2YB0
Note:
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, we provide information on the Open Platform
Program for creating your own functions or Controls for WinCC
flexible.
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /[email protected]
■ Overview
• Option for SIMATIC WinCC flexible Runtime plus SIMATIC
Panels for communication between various SIMATIC HMI
systems.
• Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 270, TP 277, OP 270, OP 277
- MP 177, MP 270B, MP 277, MP 370, MP 377
- WinCC flexible Runtime
• Communication between HMI systems is established on the
basis of Ethernet networks, or via the intranet/Internet:
- Read and write access to variables;
WinCC flexible Runtime or SIMATIC Panels make data
(variables) available to other SIMATIC HMI systems or Office
applications.
- A SIMATIC HMI system can be used to control or monitor
another system remotely;
entry level for client/server configurations for distributed operator stations or for solutions with headend or control room.
• Local operation, visualization and data processing is as
possible as plant-wide access to information or central
archiving of process data. Integrated information flows ensure
an overview of the status of all processes.
• Licensing:
The license "WinCC flexible/[email protected] for Panel" or
"WinCC flexible/[email protected] for WinCC flexible Runtime"
must be installed on both the server and client HMI device.
Server applications are the options [email protected], HTTP
Server and SOAP-Server. Client applications are the screen
object [email protected] display, and the utilization of the
communication driver SIMATIC HTTP protocol.
No license is required on the client system for access to a
[email protected] using the application [email protected] or the
Microsoft Internet Explorer. A license is also not required for
the engineering system for configuring the runtime option.
4
■ Benefits
• Flexible solution for location-independent access to HMI
systems and process data
• Reduction in load on fieldbuses:
WinCC flexible Runtime as well as SIMATIC Panels permit a
control system, for example, to access the process data. The
sensitive field level is not loaded by the control level as far as
the communications requirements are concerned.
The requirements are processed by WinCC flexible Runtime and
the SIMATIC Panels.
• Simple, fast configuration of communications relationships using the WinCC flexible engineering software
■ Application
• Use of HMI systems at machine level as data servers for
higher-level automation components such as control systems
or office systems. For example, process values from various
machines can be output in a master display.
• Control and monitoring of spatially distributed machines with
several operator stations by just one operator
• Operator control and monitoring of HMI systems at machine
level from a central station (e.g. the master station of a
production line, or from a control room)
0DVWHU&RQWURO6WDWLRQ
+773'DWD&OLHQW
6,0$7,&+0,+7733URWRFRO
,QGXVWULDO(WKHUQHW
6HUYHU
+773'DWD
6HUYHU&OLHQW
6HUYHU
+773'DWD
6HUYHU&OLHQW
6HUYHU
+773'DWD
6HUYHU&OLHQW
6HUYHU
+773'DWD
6HUYHU&OLHQW
G_ST80_XX_00070
352),%86
Communication between HMI systems using Industrial Ethernet: use of HMI systems at machine level as data servers
for higher-level automation components
Siemens ST 80 · 2009
4/25
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /[email protected]
■ Application (continued)
6P#UW6HUYHU
0DVWHU6WDWLRQ
6P#UW&OLHQW
2SHUDWRU6WDWLRQ
2SHUDWRU6WDWLRQ
2SHUDWRU6WDWLRQQ
...
4
G_ST80_XX_00071
,QGXVWULDO(WKHUQHW
Application of [email protected] concept: coordinated operation of several operator stations
0DVWHU&RQWURO6WDWLRQ
6P#UW&OLHQWGLVSOD\
,QGXVWULDO(WKHUQHW
6HUYHU
6HUYHU
6P#UW6HUYHU
6P#UW6HUYHU
6HUYHU
6P#UW6HUYHU
6HUYHU
6P#UW6HUYHU
G_ST80_XX_00072
352),%86
Application of [email protected] display: operator control and monitoring of HMI systems used at machine level from a central station
4/26
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /[email protected]
■ Function
Communication between different SIMATIC HMI systems
or between the units of a machine or plant is carried out
via Industrial Ethernet or intranet/Internet on the basis of
[email protected]
Possible communication relationships:
• Reading and writing the variables of a SIMATIC HMI system on
the basis of an HTTP protocol
- Reading and writing the variables of different HMI systems
- Simple configuring of variables in the HMI client configuration using browsers in the WinCC flexible engineering tool
- Reading and writing the variables of an HMI system using
standard applications such as MS Excel. Communication is
made possible by embedding a script in the application, on
the basis of the SOAP protocol (Simple Object Access
Protocol) superimposed by HTTP
• Remote control of an operator station;
the HMI application and communication with the PLC are via
the master station. In the case of spatially distributed machines/plants (which require a larger number of operator panels), so-called [email protected] can be activated from here which
are then assigned access to the master station and thus to the
process. Access procedures guarantee that only one operator
system can actively access the process at a time.
- A configurable graphic object ([email protected] display)
embedded in process displays represents the screen of the
associated HMI system ([email protected])
- Powerful standard functions permit convenient and flexible
operation of the display
Password protection can be optionally activated for access to
variables or for remote operation of an HMI system.
■ Technical specifications
Type
WinCC flexible /[email protected]
The specifications are maximum
values
Execution platform
• SIMATIC Panels
Mobile Panel 177 PN, Mobile Panel
277, TP/OP 177B PN/DP,
TP/OP 270, TP/OP 277
• SIMATIC Multi Panels
MP177, MP 270B, MP 277, MP 370,
MP 377
• PCs
WinCC flexible Runtime
[email protected]
SIMATIC HMI HTTP protocol
Number of connections for one
client
• Mobile Panel 177 PN,
TP/OP 177B PN/DP,
MP 177 as HTTP server
4
4
8
• Mobile Panel 277, TP/OP 270,
TP/OP 277, MP 270B, MP 277,
MP 370, MP 377 as HTTP server
• for WinCC flexible Runtime
16
[email protected]
[email protected] concept
Number of [email protected] that can
connect to a [email protected] at the
same time1) 2)
• Mobile Panel 177 PN, TP/OP 177B 2 clients
PN/DP, M177 as [email protected]
3 clients for 6" devices
• Mobile Panel 277, TP/OP 270,
TP/OP 277, MP 270B, MP277 as 2 clients for 8" and 10" devices
[email protected]
• MP 370, MP 377 as [email protected] 3 clients for 12" devices
2 clients for 15" devices
1 client for 19" devices
• for WinCC flexible Runtime as
[email protected]
5 clients
Number of [email protected] displays
per screen
• for Panels/Multi Panels
1
• for WinCC flexible Runtime
2
1)
Including 1 Service Client
2)
The [email protected] and the WinCC flexible/Pro Agent option cannot be used
simultaneously on TP/OP/MP 270/370. Parallel operation of the runtime
options ProAgent, [email protected] and [email protected] is possible in the context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the MP
377. Limitation: a maximum of 2 clients can be connected simultaneously
to a [email protected]
Siemens ST 80 · 2009
4/27
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /[email protected]
■ Ordering data
Order No.
Single license, license key only
6AV6 618-7AB01-3AB0
WinCC flexible /[email protected] B
for WinCC flexible 2008
Runtime1)
Single license, license key only
6AV6 618-7AD01-3AB0
B) Subject to export regulations: AL: N und ECCN: EAR99S
D) Subject to export regulations: AL: N und ECCN: 5D992B1
1)
4
The license must be installed on the server and on the client HMI device.
Server applications are the options [email protected], HTTP-Server and
SOAP-Server.
Client applications are the screen object [email protected] display, and the utilization of the communication driver HTTP protocol.
A license is not required for the engineering system for configuration the
runtime option.
4/28
Siemens ST 80 · 2009
■ More information
Note:
WinCC flexible /[email protected] D
for SIMATIC Panel1)
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for WinCC
flexible.
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /[email protected]
■ Overview
• Option for SIMATIC WinCC flexible Runtime and SIMATIC
Panels for remote maintenance and servicing of machines/
plant via the Internet/intranet
• Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 270, TP 277, OP 270, OP 277
- MP 177, MP 270B, MP 277, MP 370, MP 377
- WinCC flexible Runtime
• Licensing
The "WinCC flexible/[email protected] for Panel" license or
"WinCC flexible/[email protected] for WinCC flexible Runtime"
license must be installed on the operator panels that use one
of the following options/functions: [email protected], HTML pages
(mini-Web server), e-mail.
The remote service PC and engineering system do not require
a license for configuration the runtime option.
■ Benefits
• Fast elimination of faults or downtimes and thus increased
productivity by means of global access to machines/systems
by the service and maintenance personnel
• Avoids the need for site visits
■ Application
• Remote maintenance and servicing of machines and plants
via Internet/Intranet
• Calling of system information, control of target systems, and
updating of data sets via Internet/Intranet
• Automatic sending of e-mails to experts for fast elimination of
faults
■ Function
Remote operator control and monitoring of SIMATIC HMI
systems using Industrial Ethernet and/or via the Intranet/
Internet
Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for
accessing an HMI system.
Remote control of an operating station;
the HMI application and communication with the controller takes
place via the HMI system. Using [email protected], the HMI systems
in the machines/systems can be serviced remotely. An access
process ensures that only one operator (either locally at the machine or remotely via Internet Explorer) can actively access the
process at one time.
Integrated Web Server to process standard HTML pages
The following functions can be accessed from the homepage:
• Starting and stopping the HMI runtime for maintenance
• Remote access to recipe data sets, passwords and
information specific to the HMI system
• Access the HMI system files via a file explorer
• Download configuration data via the Intranet/Internet
• Supplement with own HTML pages
Sending e-mails to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
• Events that trigger an e-mail:
- Reporting of a message class
- Configurable standard functions: Changing the value of a
variable, pressing a function key, scripts, etc.
• Possible e-mail content
- Subject
- Message text with process variables
- Date/Time
• The optional use of e-mail/SMS gateways enables access to
standard networks (external service provider required)
Standard functions make maintenance and service functionality
easier. WinCC flexible allows you to quickly and easily configure
maintenance and service functions.
Password protection can be activated as an option for accessing the HMI system. Different passwords may be configured for
different functions.
Siemens ST 80 · 2009
4/29
4
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /[email protected]
■ Function (continued)
Engineering Station
PC/PG
7&3,3
(QJLQHHULQJ6WDWLRQ
3&3*
,6'1'6/
0RGHP5RXWHU
&DVH
2SHUDWRUFRQWURODQGPRQLWRULQJ
XVLQJWKH,QWHUQHW,QWUDQHWZLWK
DFFHVVWRWKHFRPSOHWHGHYLFH
VRIWNH\VDQGIXQFWLRQNH\V
&DVH
2SHUDWRUFRQWURODQGPRQLWRULQJ
XVLQJWKH0LFURVRIW,QWHUQHW([SORUHU
,QWHUQHW
,QGXVWULDO(WKHUQHW
G_ST80_XX_00073
,QGXVWULDO(WKHUQHW
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
352),%86
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
60736HUYHU
,6'1'6/
0RGHP5RXWHU
,QGXVWULDO(WKHUQHW
,QWHUQHW
,6'1'6/
0RGHP
5RXWHU
(QJLQHHULQJ
6WDWLRQ3&3*
7&3,3
7&3,3
,6'1'6/
0RGHP5RXWHU
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
4/30
Siemens ST 80 · 2009
ZZZ0(6
2IILFHDUHD
,QGXVWULDO
(WKHUQHW
G_ST80_XX_00074
352),%86
,QWHUQHW
6HUYLFH
3URYLGHU
352),%86
*B67B;;B
4
*B67B;;B
,6'1'6/
0RGHP5RXWHU
Sending e-mails to maintenance personnel via SMTP server (Simple Mail
Transfer Protocol)
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /[email protected]
■ Technical specifications
Type
■ Ordering data
WinCC flexible /[email protected]
Execution platform
• SIMATIC Panels
Mobile Panel 177 PN, Mobile
Panel 277, TP 177B PN/DP,
OP 177B PN/DP, TP/OP 270,
TP/OP 277
WinCC flexible/[email protected]
for SIMATIC Panels1)
Order No.
D
Single license, license key only
WinCC flexible/[email protected]
for WinCC flexible Runtime
20081)
6AV6 618-7BB01-3AB0
D
• SIMATIC Multi Panels
MP 177, MP 270B, MP 277,
MP 370, MP 377
Single license, license key only
• PCs
SIMATIC WinCC flexible Runtime
D) Subject to export regulations: AL: N and ECCN: 5D992B1
[email protected]
1)
Remote access via
1)
Internet Explorer V6.0 SP1 and
higher
HTML pages
6AV6 618-7BD01-3AB0
The "WinCC flexible/[email protected] for Panel" license or "WinCC flexible/[email protected] for WinCC flexible Runtime" license must be installed on
the operator panels that use one of the following options: [email protected],
HTML pages, e-mail.
The remote service PC and engineering system do not require a license for
configuration the runtime option.
• for Panels/Multi Panels
HTML V1.1 (no support for
ActiveX, Java, ASP)
• for WinCC flexible Runtime
HTML V1.1
Sending e-mails
• via SMTP server
Note:
• Subject, message texts with
250 characters of text per
e-mail; date/time of message,
message no.
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for WinCC
flexible.
1)
■ More information
The [email protected] and the WinCC flexible/ProAgent option cannot be used
simultaneously on TP/OP/MP 270/370. Parallel operation of the runtime
options ProAgent, [email protected] and [email protected] is possible in the context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the MP
377. Limitation: a maximum of 2 clients can be connected with a
[email protected]
Siemens ST 80 · 2009
4/31
4
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /OPC Server
■ Overview
Higher level visualization system
OPC Client
Industrial Ethernet
On-site visualization
OPC Server
OPC Server
OPC Server
4
Multi Panel
OPC Client
SIMATIC
S7-300
SIMATIC
S7-400
3rd party
OPC Server
3rd party
PLCs
• Option for SIMATIC WinCC flexible Runtime as well as Multi
Panels for communication with applications from different
vendors (e.g. MES, ERP, or applications in the office sector)
• Available for the following SIMATIC HMI systems:
- MP 270B, MP 277, MP 370, MP 377 (use of OPC on XML
basis)
- WinCC flexible Runtime (use of OPC based on DCOM)
• One license is required for each operator station.
■ Benefits
• Incorporation of automation components from different
vendors into an automation concept
• Saving of development costs through communication
between automation systems based on a homogeneous,
uniform protocol
• Reduction in load on fieldbuses:
WinCC flexible Runtime as well as SIMATIC Panels permit a
control system, for example, to access the process data.
The sensitive field level is not loaded by the control level as far
as the communications requirements are concerned. The
requirements are processed by WinCC flexible Runtime and
the SIMATIC Panels.
■ Application
OPC (OLE for Process Control) is a standardized, open, uniform
and multi-vendor software interface. OPC is based on the
Windows technology of COM (Component Object Model),
DCOM (Distributed COM) or on XML.
Windows-based systems such as SIMATIC Panel PC or
SIMATIC Multi Panels are used for tasks at the machine and
process levels, and can communicate with all OPC-compatible
applications via Ethernet using TCP/IP and OPC. WinCC flexible
Runtime or the SIMATIC Multi Panel (OPC server) provide data
for one or more OPC clients. As a result, local visualization and
data processing are possible to the same extent as plant-wide
calling of information or archiving of process data. Uniform flows
of information guarantee an overview of the status of all
processes.
Communication with OPC-compatible applications from
different vendors (e.g. MES, ERP, or applications in the office
sector) is possible.
OPC Foundation
Additional information is available in the Internet under:
http://www.opcfoundation.org
4/32
Siemens ST 80 · 2009
G_ST80_XX_00078
PROFIBUS
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /OPC Server
■ Function
■ Ordering data
• Use of a visualization system as a data server (OPC server) for
higher-level automation components such as control systems
or office systems
- OPC-XML server for multi panels
- OPC server (DCOM) for WinCC flexible Runtime
• The WinCC flexible engineering system can conveniently
select a desired OPC item from the variables function of the
OPC server using an OPC browser (component of the OPC
server). To do this, the OPC server must be started and must
be accessible for the engineering system.
■ Technical specifications
Type
Single license, license key only
WinCC flexible/OPC Server
Execution platform
6AV6 618-7CC01-3AB0
WinCC flexible/OPC server for D
WinCC flexible Runtime 20081)
Single license, license key only
6AV6 618-7CD01-3AB0
D) Subject to export regulations: AL: N and ECCN: 5D992B1
1)
The specifications are maximum
values
A license is required for each operator station.
The engineering system does not require a license for configuration the
runtime option.
■ More information
4
Note:
• SIMATIC Multi Panels
MP 270B, MP 277, MP 370,
MP 377
• PCs
SIMATIC WinCC flexible Runtime
OPC server
• XML server for Multi Panels
Order No.
WinCC flexible/OPC Server for D
SIMATIC Multi Panels1)
Supports the OPC XML Data
Access specification V1.01)
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for WinCC
flexible.
• DCOM server for WinCC flexible Supports the OPC Data Access
Runtime
specification V1.0a and V2.0
• Number of connections that an
OPC server can accommodate
1)
8
Data access via XML has a functional scope that is similar to OPC Data
Access. A software adapter is required that must be installed on the OPC
client PC to enable DCOM-based OPC clients to access the OPC XML
server without any modification. The software adapter is supplied with
WinCC flexible Engineering and Runtime.
Siemens ST 80 · 2009
4/33
© Siemens AG 2008
HMI Software
SIMATIC WinCC flexible RT options
WinCC flexible /ProAgent
■ Overview
■ Ordering data
Order No.
WinCC flexible /ProAgent
Software option package for
process diagnostics based on
S7-PDIAG V5.3 and higher,
S7-HighGraph V5.3 and higher;
S7-GRAPH V5.3 and higher;
functional enhancement for
SIMATIC WinCC flexible;
electronic documentation in
English, French, German, Italian
and Spanish
3B67B;;B
67(3
4
• Targeted and rapid process diagnostics in plants and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various SIMATIC
components
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time
• WinCC flexible /ProAgent for D
SIMATIC Panels1)
Runtime license (Single
License) executable on:
TP/OP 270, Mobile Panel 277,
TP/OP 277, MP 270B, MP277,
and MP 377
6AV6 618-7DB01-3AB0
• WinCC flexible /ProAgent for D
WinCC flexible Runtime
20081)
Runtime license (Single
License)
6AV6 618-7DD01-3AB0
D) Subject to export regulations: AL: N and ECCN: 5D992B1
1)
One license is required for each operator station.
The engineering system does not require a license for configuring the
runtime option.
■ More information
Note:
Note:
For further information, refer to "SIMATIC ProAgent process
diagnostics software".
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for WinCC
flexible.
4/34
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Overview
• PC-based operator control and monitoring system for visualizing and operating processes, production flows, machines and
plants in all sectors - from the simple single-user station
through to distributed multi-user systems with redundant servers and cross-location solutions with Web clients. WinCC is
the information hub for corporation-wide vertical integration.
• The basic system configuration (WinCC basic software) includes industry-standard functions for signaling and acknowledging events, archiving of messages and measured values,
logging of all process and configuration data, user administration and visualization.
• The WinCC basic software forms the core of a wide range of
different applications. Based on the open programming interfaces, a wide range of WinCC options (from Siemens Industry
Automation) and WinCC add-ons have been developed (by
Siemens-internal and external partners).
• WinCC can be operated with every PC that meets the given
HW requirements. The product range of the SIMATIC Panel PC
and SIMATIC Rack PC is available in particular for the industrial usage of WinCC systems. SIMATIC PCs stand out due to
their powerful PC technology, are designed for round-theclock operation, and can be operated in both harsh industrial
environments and office areas.
Current versions:
• SIMATIC WinCC V7.0:
Executable with
- Windows VISTA 32-bit Ultimate, Business and Enterprise
- Windows XP Professional
- Windows 2003 Server and Windows 2003 Server R2
Contains the Microsoft SQL Server 2005 SP2
• SIMATIC WinCC V6.2 SP2:
Executable with
- Windows XP Professional
- Windows 2000 Professional
- Windows Server 2003 and Windows Server 2003 R2
Contains the Microsoft SQL Server 2005 SP1
■ Benefits
• All-purpose
- Solutions for all sectors
- Multilingual for worldwide usage
- Can be integrated into all automation solutions
• All HMI functions on board
- User administration
- Operator control and monitoring
- Reporting, acknowledging, and archiving of events
- Acquisition, compression and archiving of measured values
(incl. long-term backup)
- Logging and documenting of process and configuration
data
• Can be configured simply and efficiently
- Configuration wizards let the user focus on the essentials
- In the picture by means of cross-reference lists and screen
property displays
- Configuration of multilingual applications
- Configuring tool for configuring bulk data
• Universally scalable
- Expandable from single station to client-server configurations
- Increased availability by means of redundant servers
- Process visualization via the web with the WinCC
WebNavigator
• Open standards for simple integration
- Efficient real-time database MS SQL Server 2005
- Open for application modules with ActiveX controls
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication
• Process visualization with Plant Intelligence
- Integrated high-performance Historian on the basis of the
Microsoft SQL Server 2005
- Integrated evaluation functions for the online analysis
(statistical process control)
- Production optimization with the help of diverse options
• Expandable using options and add-ons
- Options for scalable configurations
- Options for increasing the availability
- Options for IT & business integration
- Options for SCADA expansions
- Options for validation in accordance with FDA 21 CFR
Part 11
• Part of Totally Integrated Automation
- Direct access to the tag and message configuration of the
SIMATIC control system
- Integrated diagnostic functions for increasing productivity
Siemens ST 80 · 2009
4/35
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Benefits (continued)
Innovations of V7.0
Innovated runtime user interface
• New graphical options such as transparency, color gradients,
shades, and much more
• Central management of switching between graphic designs
• Central management of switching between color palettes
• New graphical objects: combo boxes, list boxes, text fields
with multiple lines, multimedia control and much more
4
New, revised runtime controls
• An unlimited number of alarms can be displayed in Alarm
Control
• User-specific filter options in Alarm Control
• Identical, expanded layout for messages, trend curves, tables
and UserArchive Control
New, centrally modifiable graphic objects/faceplates
• New, easy to configure faceplates with the option of centralized modification.
• Can be used and configured on a cross-project basis in the
Graphics Designer
Additional configuration options
• Can run as service and is thus suitable for use in existing IT
server environments.
• The standard client without Microsoft SQL Server installation
reduces the installation costs and the hardware requirements
• Revised and simplified WinCC setup with one-click installation
option
Improved support for multi-language projects
• New, central editor for importing and exporting all WinCC texts
• New filter mechanisms in the text library for simplified
management of texts
SIMATIC Logon centralized user administration
(included in the scope of supply)
... and more
■ Application
SIMATIC WinCC is designed for visualization and operation of
processes, manufacturing cycles, machines and plants. With its
powerful process interface, especially to the SIMATIC family,
and the secure data archiving, WinCC enables highly available
solutions for the process control.
The sector-neutral basic system enables universal usage in all
automation applications. Sector-specific solutions can, for
example, be implemented using WinCC options (e.g. FDA
options for the pharmaceutical industry) and sector-specific
add-ons (e.g. for the water industry).
■ Design
SIMATIC WinCC is available as a complete package and as a
runtime package with 128, 512, 2048, 8192, 65536, 102400,
153600, 262144 PowerTags 1). PowerTags are data points that
are connected to controllers or other data sources over a WinCC
channel. Up to 32 alarms can be obtained from one data point.
Moreover, internal tags without coupling are available for additional system performance. In addition WinCC also contains 512
archive tags. Individual archive licenses can be obtained for
greater quantity structures.
Licenses for a multi-user configuration
The system software with the required number of PowerTags and
additionally the option WinCC/server must be installed on the
server. In the basic configuration, an RT128 license is sufficient
for the clients. In order to configure on clients, an RC128 license
is required.
1)
V6: 128, 256, 1024, 8192, 65536 PowerTags
■ Function
The powerful configuration functions of SIMATIC WinCC contribute to a reduced engineering and training overhead and lead to
a more flexible use of personnel and greater operational reliability. Whoever is familiar with Microsoft Windows can also operate
the WinCC Explorer, the central switching point of WinCC.
In combination with other SIMATIC components, the system is
also equipped with auxiliary functions such as process diagnostics and maintenance. All SIMATIC engineering tools work together in the configuration of the functions.
SIMATIC WinCC offers a complete basic functionality for process visualization and operation. To this end WinCC has a number of editors and interfaces that can be used to individually
configure this functionality according to the respective application. Expansions of a WinCC station for control tasks are also
possible with minimal engineering effort.
4/36
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Function (continued)
■ Integration
WinCC editors
Task or configurable runtime
functionality
Integration in company-wide solutions (IT and
business integration)
WinCC Explorer
Central project management for the
quick access to all project data
and central settings
WinCC Graphics Designer
Graphics system for user-defined
visualization and operation via
pixel-graphic objects
WinCC Alarm Logging
Signaling system for detecting and
archiving events with display and
control options according to DIN
19235; freely selectable message
classes, message display and logging
WinCC Tag Logging
Process archiving for the acquisition, compression and storage of
measured values, e.g., presentation in trend and table format as
well as further processing
WinCC is strictly based on Microsoft technology, which provides
for the greatest possible compatibility and integration ability.
ActiveX and .net 1) controls support technology and sector-specific expansions. Cross-manufacturer communication is also a
simply exercise. The reason: WinCC can be used as an OPC
client and server, and in addition to access to current process
values, it also supports standards such as OPC HDA (Historical
Data Access), OPC Alarm & Events, and OPC XML Data Access. Just as important: Visual Basic for Applications (VBA) for
user-specific expansions of the WinCC Graphics Designer and
Visual Basic Scripting (VBS) as an easy-to-learn, open runtime
language. If desired, professional application developers can
also use ANSI-C. And the access to the API programming interfaces is really simple with the Open-Development-Kit ODK.
WinCC Report Designer
Reporting and logging system for
time and event-controlled documentation of messages, operator
inputs and current process data in
the form of user reports or project
documentation in an arbitrary layout
WinCC User Administrator
Tool for user-friendly administration
of users and authorizations
WinCC Global Script
Processing functions with limitless
functionality by means of the use of
VBScript and ANSI-C
WinCC integrates a powerful and scalable Historian function
based on the Microsoft SQL Server 2005 in the basic system.
Thus the user is given all possibilities: from high-performance
archiving of current process data, to long-term archiving with
high data compression, through to a central information turntable in form of a company-wide Process Historian. With the help
of the option Central Archive Server, this can be created within
the framework of a WinCC solution. Versatile clients and tools for
evaluation, the open interfaces, special options (Connectivity
Pack, Connectivity Station, IndustrialDataBridge) provide the
basis for an effective IT and business integration.
1)
Only supported by WinCC V7.0
Integration in automation solutions
WinCC is an open process visualization system and offers the
option of connecting the most diverse control systems.
Interfaces
Task or configurable runtime
functionality
Communication channels
For communication with subordinate controls (SIMATIC protocols,
PROFIBUS DP, PROFIBUS FMS,
DDE and OPC server included in
the scope of delivery)
Standard interfaces
For the open integration of other
Windows applications via WinCC,
WinCC-OLE-DB, ActiveX, OLE,
DDE, OPC, etc.)
Programming ports
For the individual access to data
and functions of WinCC and for the
integration in user programs with
VBA, VB Script, C-API (ODK),
C-Script (ANSI-C)
Released communication software
Only communication software with the listed (or higher) product
versions should be used. Corresponding SIMATIC NET upgrades are available for the upgrading of older versions.
Siemens ST 80 · 2009
4/37
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
4
Number of connectable controls
Channel-DLL PROFIBUS DP
For the number of the connectable controls via Industrial
Ethernet CP 1613, the following applies for a message frame
length of 512 bytes:
In accordance with the PROFIBUS standard, DP/slaves are
always permanently assigned to a DP master; i.e. a second
WinCC station (DP/master) cannot access the same controls
(DP/slave) This means that a redundant operation of two WinCC
stations is not possible with the use of the PROFIBUS DP
coupling.
Type of coupling
Number of nodes
SIMATIC S5 Ethernet Layer 4 +
TCP/IP
up to 60
SIMATIC S7 Protocol Suite
up to 64
SIMATIC 505 Ethernet Layer 4 +
TCP/IP
up to 60
Via PROFIBUS, a maximum of 8 controls with CP 5611 and a
maximum of 44 controls with CP 5613 can be connected. With
approx. 10 or more controls, the usage of Industrial Ethernet is
recommended.
Mixed mode with different controls
With their multi-protocol stack, the communications processors
CP 1613 and CP 5613 allow for the parallel operation of two protocols, e.g. for the mixed operation of different controls via a bus
cable. WinCC supports the operation of two similar interface
boards only in connection with the channels SIMATIC S5 Ethernet Layer 4 (2 x CP 1613), SIMATIC S7 Protocol Suite (2 x
CP 1613, 2 x CP 5613) as well as PROFIBUS DP (4 x CP 5613;
each CP 5613 max. 122 slaves). In addition to communication
over industrial Ethernet CP 1613 or PROFIBUS CP 5613, one CP
5611 for communication with SIMATIC S7 via MPI can be used
in each case.
Client-server communication
The communication between the clients and the server is
achieved using the TCP/IP protocol. The construction of a separate PC-LAN is recommended. For small projects with correspondingly small message frame advent, a SIMATIC NET Industrial Ethernet can be used for both process communication
(WinCC/Server ↔ PLC) and for the PC-PC communication
(WinCC/client ↔ WinCC/server)
4/38
Siemens ST 80 · 2009
Connection to controls from other manufacturers:
For the connection of controls from other manufacturers, OPC
(OLE for Process Control) is recommended.
Current notes and information about OPC servers from various
suppliers can be found at:
http://www.opcfoundation.org
WinCC supports the standards:
• OPC Data Access 1.1
• OPC Data Access 2.05a
• OPC Data Access 3.0
• OPC XML Data Access 1.01 (Connectivity Pack/Connectivity
Station)
• OPC HDA 1.2 (Connectivity Pack/Connectivity Station)
• OPC A&E 1.1 (Connectivity Pack/Connectivity Station)
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Coupling overview
Protocol
Description
SIMATIC S7
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions via MPI, PROFIBUS or Ethernet Layer 4 + TCP/IP
SIMATIC S5
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4 communication + TCP/IP
SIMATIC S5 Programmer Port AS511
Channel DLL and driver for serial communication with S5 via AS511 protocol to
programmers port
SIMATIC S5 Serial 3964R
Channel DLL and driver for serial communication with S5 via RK512 protocol
SIMATIC S5 PROFIBUS-FDL
Channel DLL for S5-FDL
SIMATIC 505
SIMATIC 505 Serial
Channel DLL and driver for serial communication with 505 via NITP/TBP protocol to
SIMATIC 535/545/555/565/575
SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer 4 communication
SIMATIC 505 TCP/IP
Channel DLL for 505 TCP/IP communication
Non-Siemens controllers (from WinCC V7.0)
Allen Bradley
Ethernet IP
Channel DLL and drivers for communication with Allen Bradley ControlLogix controllers
via Ethernet TCP/IP with Ethernet IP protocol
Modbus TCP/IP
Channel DLL and drivers for communication with Modiconix controllers via Ethernet
TCP/IP with Modbus TCP/IP protocol
Cross-manufacturer
Windows DDE
Channel DLL for DDE communication, WinCC can acquire data from DDE server
applications.
OPC client1)
Channel DLL for OPC communication, WinCC can acquire data from OPC server
applications.
OPC server
Server applications for OPC communication; WinCC provides process data for OPC
client
PROFIBUS FMS
Channel DLL for PROFIBUS FMS
PROFIBUS DP
Channel DLL for PROFIBUS DP
1)
Application note:
The parallel usage of the OPC client channel allows, for example, the
connection to an SNMP-OPC server for visualization of the data contained
there. The SNMP-OPC server enables monitoring of any network components (e.g. switch) that support the protocol SNMP. You can find more
information under SIMATIC NET Communications Systems/SNMP OPC
Server.
Siemens ST 80 · 2009
4/39
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.0)
Industrial Ethernet
SIMATIC
S5
Ethernet
Layer 4
SIMATIC
S5
TCP/IP
I
I
SIMATIC
S7
Protocol
Suite
SIMATIC
505
Ethernet
Layer 4
SIMATIC
505
TCP/IP1)
Order No.
WinCC – channel DLL
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4
communication + TCP/IP
Included in the basic
package
I
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
I
SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer
4 communication
4
Included in the basic
package
SIMATIC 505 TCP/IP1)
Channel DLL for 505 TCP/IP
communication
Included in the basic
package
I
Included in the basic
package
I
6GK1 161-2AA00
Communication components for extension of the OS/OP
CP 1612
PCI card for connecting a PG/PC to
Industrial Ethernet (SOFTNET-S7 or
SOFTNET-S7 Lean communications
software must be ordered separately)
I
I
SOFTNET-S7 20072)
communications software for
S7 functions (max. 64 connections)
I
I
6GK1 704-1CW70-3AA0
SOFTNET-S7 Lean 20072)3)
Communications software for S7
functions (max. 8 connections)
I
I
6GK1 704-1LW70-3AA0
I
I
I
I
I
6GK1 161-3AA00
I
CP 1613 A2
PCI card (32-bit) for connecting a PG/PC
to Industrial Ethernet (S7-1613 communications software required)
I
I
I
I
6GK1 161-3AA01
I
CP 1623
PCI Express card (32-bit) for connecting
a PG/PC to Industrial Ethernet (S7-1613
communications software required)
I
I
I
I
6GK1 162-3AA00
S7-1613 20072)
communications software for
S7 functions and S5/505 Layer 4
communication with TCP/IP
I
I
I
• For Windows XP/2003 Server Vista
32 bit
CP 1613
PCI card for connecting a PG/PC to
Industrial Ethernet (S7-1613 communications software must be ordered
separately)
I
• For Windows XP/2003 Server/
Vista 32 bit
I
System coupling is possible
1)
Via any interface board with NDIS 3.0 interface; no separate communications software required
2)
Upgrade packages, see order data
3)
SOFTNET-S7 Lean 2007 included in the scope of supply of WinCC V7.0
4/40
Siemens ST 80 · 2009
6GK1 716-1CB70-3AA0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.0)
PROFIBUS
SIMATIC S5
PROFIBUS FDL
SIMATIC S7
Protocol Suite
PROFIBUS DP
PROFIBUS FMS
Order No.
WinCC – channel DLL
SIMATIC S5 PROFIBUS FDL
Channel DLL for S5-FDL
I
Included in the basic
package
I
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
Included in the basic
package
I
PROFIBUS DP
Channel DLL for PROFIBUS DP
Included in the basic
package
I
PROFIBUS FMS
Channel DLL for PROFIBUS FMS
Included in the basic
package
Communication components for extension of the OS/OP
CP 5611 A2
PCI card (32 bit) for the connection
of PG/PC to PROFIBUS or MPI
(communications software included in
the WinCC basic package)
I
6GK1 561-1AA01
CP 5621
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
or MPI
I
6GK1 562-1AA00
CP 5512
PCMCIA card (Cardbus 32 bit) for the
connection of PG/PC to PROFIBUS or
MPI (communications software
included in WinCC basic package)
I
6GK1 551-2AA00
PC/MPI adapter
RS 232, 9-pin, pins with
RS 232/MPI converter
max. 19.2 Kbit/s
I
6ES7 972-0CA23-0XA0
CP 5613 A2
PCI card (32 bit) for connecting a
PC to PROFIBUS (S7-5613
communications software or
DP-5613 or FMS-5613 required)
I
I
S7-5613 20071) Communications
software for S7 functions + FDL
I
I
I
I
4
6GK1 561-3AA01
6GK1 713-5CB70-3AA0
• For Windows XP/2003 Server/Vista
32 bit
DP-5613 20071)
Communication software for
DP-Master + FDL
I
I
6GK1 713-5DB70-3AA0
• For Windows XP/2003 Server/Vista
32 bit
FMS-5613 20071)
Communication software for
PROFIBUS-FMS + FDL
I
I
6GK1 713-5FB70-3AA0
• For Windows XP/2003 Server/Vista
32 bit
I
System coupling is possible
1)
See ordering data for upgrade package
Siemens ST 80 · 2009
4/41
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communication examples
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
SIMATIC NET PROFIBUS (S7 functions)
- CP 5613 A2
6GK1 561-3AA01
- CP 5621
6GK1 562-1AA00
- S7-5613
(communication software)
6GK1 713-5CB70-3AA0
PROFIBUS
SIMATIC S7-400
SIMATIC S7-300
- CP 443-5 Extended
(DP/M, S7, S/R)
6GK7 443-5DX04-0XE0
- CP 443-5 Basis (FMS, S7, S/R)
6GK7 443-5FX02-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
- CP 342-5 (DP, S7, S/R)
6GK7 342-5DA02-0XE0
- CP 343-5 (FMS, S7, S/R)
6GK7 343-5FA01-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
G_ST80_XX_00010
4
WinCC single-user system: PROFIBUS with S7 communication
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
SIMATIC NET PROFIBUS (S7 functions)
- CP 1613 A2
6GK1 161-3AA01
- CP 1623
6GK1 162-3AA00
- S7-1613
(communication software)
6GK1 716-1CB70-3AA0
Industrial Ethernet
- CP 443-1 (S7, S/R) ISO + TCP
6GK7 443-1EX20-0XE0
- CP 443-1 Advanced
(S7, S/R, HTTP)
6GK7 443-1GX20-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
WinCC single-user system: Industrial Ethernet with S7 communication
4/42
Siemens ST 80 · 2009
SIMATIC S7-300
- CP 343-1 (S7, S/R) ISO + TCP
6GK7 343-1EX30-0XE0
- CP 343-1 Advanced
(S7, S/R, HTTP)
6GK7 343-1GX30-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
G_ST80_XX_00011
SIMATIC S7-400
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communication examples (continued)
SIMATIC NET PROFIBUS-FMS
- CP 5613 A2
6GK1 561-3AA00
- CP 5621
6GK1 562-1AA00
- FMS-5613
(communication software)
6GK1 713-5FB70-3AA0
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
+ FMS channel DLL
PROFIBUS FMS
4
SIMATIC S7-400
SIMATIC S7-300
- CP 443-5 Basic
- CP 343-5
(FMS, S7, S/R)
(FMS, S7, S/R)
6GK7 343-5FA01-0XE0 6GK7 443-5FX02-0XE0
SIMATIC S5115/135/155U
- COM 5431 FMS/DP
6GK1 745-1AD00-0EA0
G_ST80_XX_00012
- CP 5431 FMS/DP
6GK1 543-1AA01
WinCC single-user system: PROFIBUS FMS
without
operator controls:
32 clients
+ 3 web clients
or
50 web clients
+ 1 client
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
up to 4 clients
with operator
controls
+ TCP/IP
interface module
Client
Client
TERMINAL BUS TCP/IP
Server
PROCESS BUS (Industrial Ethernet/PROFIBUS)
SIMATIC S7-300
This allows you to set up the following application examples
- WinCC single-user system: SIMATIC NET PROFIBUS with S7 functions
- WinCC single-user system: SIMATIC NET Industrial Ethernet with S7 functions
- WinCC single-user system: SIMATIC NET PROFIBUS-FMS
G_ST80_XX_00013
SIMATIC S7-400
WinCC multi-user system with operable server
Siemens ST 80 · 2009
4/43
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communication examples (continued)
Higher-level visualisation system
- OPC server functionality
(included in WinCC basic package)
- TCP-IP interface board
required
OPC Client
Industrial Ethernet
On-site visualization
OPC Server
OPC Server
- OPC Server
functionality
(included in
WinCC basic
package)
- TCP-IP Interface
board required
OPC Client
- integrated
PROFIBUS
interface
OPC Server
PROFIBUS
SIMATIC S7-300
SIMATIC S7-400
third-party
PLCs
OPC link
4/44
Siemens ST 80 · 2009
- OPC Client
functionality
(included in
WinCC basic
package)
- OPC Server
required for
interfacing with
third-party PLCs
G_ST80_XX_00015
4
- OPC server
functionality
(included in
ProTool/Pro
Runtime
basic package)
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Technical specifications
Type
SIMATIC WinCC V7.0
SIMATIC WinCC V6.2 SP2
Operating system
• Windows VISTA Ultimate, Business and Enterprise
• Windows XP Professional SP2
• Windows 2003 Server SP2 and Windows 2003
Server R2 SP2
• Windows XP Professional SP2
• Windows 2000 Professional SP4
• Windows Server 2003 SP2
• Windows Server 2003 R2 SP2
Single-user station/server:
Pentium 3, 1 GHz2)
Single-user station/server:
Pentium III, 1 GHz
Central Archive Server:
Pentium 4, 2.5 GHz
Central Archive Server:
Pentium 4, 2 GHz
Client:
Pentium 3, 800 MHz2)
Client:
Pentium III, 600 MHz
PC hardware requirements
Processor type1)
• Minimum
4
WebClient/DataMonitor Client: Pentium III,
600 MHz2)
• Recommended
Single-user station/server:
Pentium 4, 2.5 GHz2)
Single-user station/server: Pentium 4, 2 GHz
Central Archive Server:
Pentium 4 or Dual Core, 3 GHz
Central Archive Server:
Pentium 4, 2.5 GHz
Client: Pentium 4, 2 GHz2)
Client: Pentium III, 1 GHz
WebClient/DataMonitor Client: Pentium III, 1 GHz
WebClient/DataMonitor Client: Pentium III, 1 GHz
Single-user station/server: 1 GB2)
Single-user station: 512 MB, server: 1 GB
Central Archive Server: 2 GB
Central Archive Server: 1 GB
RAM
• Minimum
Client: 512
MB2)
Client: 512 MB
WebClient/DataMonitor Client: 256 MB2)
WebClient/DataMonitor Client: 256 MB
Single-user station/server: 2 GB2)
Single-user station: >= 1 GB,
server: >1 GB
Central Archive Server: ≥ 2 GB
Central Archive Server: ≥ 2 GB
Client: 1 GB2)
Client: 512 MB
WebClient/DataMonitor Client: 512 MB2)
WebClient/DataMonitor Client: 512 MB
• Minimum
16 MB, 800 x 600 2)
16 MB, 800 x 600
• Recommended
32 MB, 1280 x 1024 2)
32 MB, 1280 x 1024
Single-user station/server: 20 GB
Single-user station/server: 20 GB
Client: 5 GB
Client: 5 GB
Central Archive Server: 40 GB
Central Archive Server: 40 GB
WebClient/DataMonitor Client: 5 GB
WebClient/DataMonitor Client: 5 GB
Single-user station/server: 80 GB
Single-user station/server: 80 GB
Client: 20 GB
Client: 20 GB
Central Archive Server: 2 x 80 GB
Central Archive Server: 2 x 80 GB
WebClient/DataMonitor Client: 10 GB
WebClient/DataMonitor Client: 10 GB
Server: >1.5 GB
Server: 1.5 GB
Client: 1.5 GB
Client: 1 GB
Server: >10 GB
Server: >10 GB
Client: >1.5 GB
Client: >1.5 GB
for software installation
for software installation
• Recommended
Graphics card
Hard disk
• Minimum
• Recommended
• Hard disk (free memory space
for installation)
- Minimum
- Recommended
CD ROM/DVD ROM/diskette
drive/USB interface
1)
An AMD system with comparable performance can also be used
2)
Hardware requirement when using Microsoft XP Professional
Siemens ST 80 · 2009
4/45
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Technical specifications (continued)
Type
SIMATIC WinCC
Functionality/quantity structure
Number of messages
150.000
• Message text
(number of characters)
10 x 256
• Alarm log
> 500,000 messages1)
• Process values per message
10
• Constant load of messages, max. Central Archive Server: 100/sec
Server/single-user station: 10/s
• Message burst, max.
Server/single-user station:
2,000/10 s every 5 min
Type
SIMATIC WinCC
PowerTags
256 K3)
Trends
• Trend views per image
25
• Trends per trend view
80
User administration
• User groups
128
• Number of users
128
• Authorization groups
999
Configuration languages
5 European (Eng., Fr., Ger., It., Sp.),
4 Asian (simpl.+trad. Chi/
Kor/Jpn)5)
Archives
4
• Archive data points
Max. 120,000 per server2)
• Archive types
Short-term archive with and
without long-term archiving
• Data storage format
Microsoft SQL Server 2005
• Measured values per second,
max.
Server/single-user station: 5,000/s
User archive
• Archives and views
500 each
• Product consisting of data record 320.000
and column per user archive
• Fields per user archive
500
Graphics system
• Number of screens
System-limited1)
• Number of objects per screen
System-limited1)
• Number of controllable fields
per screen
System-limited1)
1)
Dependent on the available storage space
2)
Dependent on the number of licensed archive variables
3)
Dependent on number of licensed PowerTags
4)
Asian versions for Version 7 SP1 or higher
5)
The number of variables per report is dependent on process
communication performance
■ Ordering data
Protocols
• Message sequence reports
(simultaneously)
1 per server/single-user station
• Message archive reports
(simultaneously)
3
• User reports
System-limited 1)
• Report lines per group
66
• Variables per report
300 5)
Multi-user system
• Server
12
• Clients for server with
operator station
4
• Clients for server without
operator station
32 clients + 3 WebClients or
50 WebClients + 1 client
Order No.
Order No.
SIMATIC WinCC system software V7.0
SIMATIC WinCC system software V7.0 (continued)
Runtime packages on DVD
Complete packages on DVD
Language/script versions:
DE/EN/FR/IT/ES; with license for
Language versions:
DE/EN/FR/IT/ES; with license for
• 128 PowerTags (RT 128)
6AV6 381-2BC07-0AX0
• 128 PowerTags (RC 128)
6AV6 381-2BM07-0AX0
• 512 PowerTags (RT 512)
6AV6 381-2BD07-0AX0
• 512 PowerTags (RC 512)
6AV6 381-2BN07-0AX0
• 2048 PowerTags (RT 2048)
6AV6 381-2BE07-0AX0
• 2048 PowerTags (RC 2048)
6AV6 381-2BP07-0AX0
• 8192 PowerTags (RT 8192)
6AV6 381-2BH07-0AX0
• 8192 PowerTags (RC 8192)
6AV6 381-2BS07-0AX0
• 65536 PowerTags (RT 65536)
6AV6 381-2BF07-0AX0
• 65536 PowerTags (RC 65536)
6AV6 381-2BQ07-0AX0
• 102400 PowerTags (RT 102400)
6AV6 381-2BJ07-0AX0
• 102400 PowerTags (RT 102400)
6AV6 381-2BT07-0AX0
• 153600 PowerTags (RT 153600)
6AV6 381-2BK07-0AX0
• 153600 PowerTags (RT 153600)
6AV6 381-2BU07-0AX0
• 262144 PowerTags (RT 262144)
6AV6 381-2BL07-0AX0
• 262144 PowerTags (RT 262144)
6AV6 381-2BV07-0AX0
Incl. 512 archive tags each
4/46
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data (continued)
Order No.
Order No.
SIMATIC WinCC V7.0 PowerPacks
SIMATIC WinCC Upgrade/Comprehensive Support
For upgrading from:
SIMATIC WinCC V7 upgrade1)
Runtime packages
For upgrading the RT version
• 128 to 512 PowerTags
6AV6 371-2BD07-0AX0
• from V6.0 to V7.0
B
6AV6 381-2AA07-0AX4
• 128 to 2048 PowerTags
6AV6 371-2BE07-0AX0
• from V6.2 to V7.0
B
6AV6 381-2AA07-0AX3
• 128 to 8192 PowerTags
6AV6 371-2BK07-0AX0
• 128 to 65536 PowerTags
6AV6 371-2BF07-0AX0
For upgrading the Client RT
version
• 512 to 2048 PowerTags
6AV6 371-2BG07-0AX0
• from V6.0 to V7.0
B
6AV6 381-2BC07-0AX4
• from V6.2 to V7.0
B
6AV6 381-2BC07-0AX3
• from V6.0 to V7.0
B
6AV6 381-2AB07-0AX4
• from V6.2 to V7.0
B
6AV6 381-2AB07-0AX3
• 512 to 8192 PowerTags
6AV6 371-2BL07-0AX0
• 512 to 65536 PowerTags
6AV6 371-2BH07-0AX0
• 2048 to 8192 PowerTags
6AV6 371-2BM07-0AX0
• 2048 to 65536 PowerTags
6AV6 371-2BJ07-0AX0
• 8192 to 65536 PowerTags
6AV6 371-2BN07-0AX0
• 65536 to 102400 PowerTags
6AV6 371-2BP07-0AX0
• 102400 to 153600 PowerTags
6AV6 371-2BQ07-0AX0
• 153600 to 262144 PowerTags
6AV6 371-2BR07-0AX0
For upgrading the RC version
Software Update Service for
WinCC basic software and
options:
• 1 license
6AV6 381-1AA00-0AX5
Complete packages
• 3 licenses
6AV6 381-1AA00-0BX5
• 128 to 512 PowerTags
6AV6 371-2BD17-0AX0
• 10 licenses
6AV6 381-1AA00-0CX5
• 128 to 2048 PowerTags
6AV6 371-2BE17-0AX0
SIMATIC WinCC V6.2 SP2 system software
• 128 to 8192 PowerTags
6AV6 371-2BK17-0AX0
Runtime packages on CD-ROM
• 128 to 65536 PowerTags
6AV6 371-2BF17-0AX0
• 512 to 2048 PowerTags
6AV6 371-2BG17-0AX0
Language/script versions:
DE/EN/FR/IT/ES; with license for
• 512 to 8192 PowerTags
6AV6 371-2BL17-0AX0
• 512 to 65536 PowerTags
6AV6 371-2BH17-0AX0
• 2048 to 8192 PowerTags
6AV6 371-2BM17-0AX0
• 2048 to 65536 PowerTags
6AV6 371-2BJ17-0AX0
• 8192 to 65536 PowerTags
6AV6 371-2BN17-0AX0
• 65536 to 102400 PowerTags
6AV6 371-2BP17-0AX0
• 102400 to 153600 PowerTags
6AV6 371-2BQ17-0AX0
• 153600 to 262144 PowerTags
6AV6 371-2BR17-0AX0
Language versions:
DE/EN/FR/IT/ES; with license for
• 128 PowerTags (RC 128)
6AV6 381-1BM06-2AX0
• 1500 archives
6AV6 371-1DQ17-0AX0
• 256 PowerTags (RC 256)
6AV6 381-1BN06-2AX0
• 5000 archives
6AV6 371-1DQ17-0BX0
• 1024 PowerTags (RC 1024)
6AV6 381-1BP06-2AX0
• 10000 archives
6AV6 371-1DQ17-0CX0
• 8192 PowerTags (RC 8192)
6AV6 381-1BS06-2AX0
• 30000 archives
6AV6 371-1DQ17-0EX0
• 65536 PowerTags (RC 65536)
6AV6 381-1BQ06-2AX0
• 80000 archives
6AV6 371-1DQ17-0GX0
Incl. 512 archive tags each
• 120000 archives
6AV6 371-1DQ17-0JX0
SIMATIC WinCC V7.0 Archive
4
SIMATIC WinCC Comprehensive Support 2)3)
• 128 PowerTags (RT 128)
6AV6 381-1BC06-2AX0
• 256 PowerTags (RT 256)
6AV6 381-1BD06-2AX0
• 1024 PowerTags (RT 1024)
6AV6 381-1BE06-2AX0
• 8192 PowerTags (RT 8192)
6AV6 381-1BH06-2AX0
• 65536 PowerTags (RT 65536)
6AV6 381-1BF06-2AX0
Incl. 512 archive tags each
Complete packages on CD-ROM
SIMATIC WinCC V7.0 Archive PowerPacks
For upgrading archiving from
• 1500 to 5000 archive tags
6AV6 371-1DQ17-0AB0
• 5000 to 10000 archive tags
6AV6 371-1DQ17-0BC0
• 10000 to 30000 archive tags
6AV6 371-1DQ17-0CE0
• 30000 to 80000 archive tags
6AV6 371-1DQ17-0EG0
• 80000 to 120000 archive tags
6AV6 371-1DQ17-0GJ0
1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station
2)
Comprehensive Support runs for 1 year. The contract is automatically
extended by 1 more year unless canceled 3 months prior to expiration.
According to licensing provisions, 1 Comprehensive Support package
must be ordered for each WinCC station.
3)
Requires the current software version
B) Subject to export regulations: AL: N and ECCN: EAR99S
Siemens ST 80 · 2009
4/47
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data (continued)
Order No.
SIMATIC WinCC V6.2 SP2 ASIA system software
4
Order No.
SIMATIC WinCC V6.2 Archive
Runtime packages on CD-ROM
• 1500 archives
6AV6 371-1DQ16-2AX0
Language versions: English/
simplified and traditional
Chinese/Korean/Taiwanese/
Japanese; with license for
• 5000 archives
6AV6 371-1DQ16-2BX0
• 10000 archives
6AV6 371-1DQ16-2CX0
• 30000 archives
6AV6 371-1DQ16-2EX0
• 128 PowerTags (RT 128)
6AV6 381-1BC06-2AV0
• 80000 archives
6AV6 371-1DQ16-2GX0
• 256 PowerTags (RT 256)
6AV6 381-1BD06-2AV0
• 120000 archives
6AV6 371-1DQ16-2JX0
• 1024 PowerTags (RT 1024)
6AV6 381-1BE06-2AV0
SIMATIC WinCC V6.2 Archive PowerPacks
• 8192 PowerTags (RT 8192)
6AV6 381-1BH06-2AV0
For upgrading archiving from
• 65536 PowerTags (RT Max)
6AV6 381-1BF06-2AV0
• 1500 to 5000 archive tags
6AV6 371-1DQ16-2AB0
Incl. 512 archive tags each
• 5000 to 10000 archive tags
6AV6 371-1DQ16-2BC0
Complete packages on CD-ROM
• 10000 to 30000 archive tags
6AV6 371-1DQ16-2CE0
Language versions: English/
simplified and traditional
Chinese/Korean/Taiwanese,
Japanese; with license for
• 30000 to 80000 archive tags
6AV6 371-1DQ16-2EG0
• 80000 to 120000 archive tags
6AV6 371-1DQ16-2GJ0
SIMATIC WinCC V6.2 upgrade1)
• 128 PowerTags (RC 128)
6AV6 381-1BM06-2AV0
• 256 PowerTags (RC 256)
6AV6 381-1BN06-2AV0
• from V5.x to V6.2 SP2
B
6AV6 381-1AA06-2AX4
• 1024 PowerTags (RC 1024)
6AV6 381-1BP06-2AV0
• from V6.x to V6.2 SP2
B
6AV6 381-1AA06-2AX3
• 8192 PowerTags (RC 8192)
6AV6 381-1BS06-2AV0
• from V5.x ASIA to V6.2 SP2 ASIA B
6AV6 381-1AA06-2AV4
• 65536 PowerTags (RC Max)
6AV6 381-1BQ06-2AV0
• from V6.x ASIA to V6.2 SP2 ASIA B
6AV6 381-1AA06-2AV3
For upgrading the RT version
Incl. 512 archive tags each
For upgrading the RC version
SIMATIC WinCC V6.2 PowerPacks
• from V5.x to V6.2 SP2
B
6AV6 381-1AB06-2AX4
For upgrading from:
• from V6.x to V6.2 SP2
B
6AV6 381-1AB06-2AX3
Runtime packages
• from V5.x ASIA to V6.2 SP2 ASIAB
6AV6 381-1AB06-2AV4
6AV6 381-1AB06-2AV3
• 128 to 256 PowerTags
6AV6 371-1BD06-2AX0
• from V6.x ASIA to V6.2 SP2 ASIAB
• 128 to 1024 PowerTags
6AV6 371-1BE06-2AX0
SIMATIC WinCC documentation (to be ordered separately)
• 128 to 8192 PowerTags
6AV6 371-1BK06-2AX0
• 128 to 65536 PowerTags
6AV6 371-1BF06-2AX0
SIMATIC WinCC V6
Communication Manual
• 256 to 1024 PowerTags
6AV6 371-1BG06-2AX0
• 256 to 8192 PowerTags
6AV6 371-1BL06-2AX0
Communication manual for
process communication and OPC
communication from WinCC V6
• 256 to 65536 PowerTags
6AV6 371-1BH06-2AX0
• German
6AV6 392-1CA06-0AA0
• 1024 to 8192 PowerTags
6AV6 371-1BM06-2AX0
• English
6AV6 392-1CA06-0AB0
• 1024 to 65536 PowerTags
6AV6 371-1BJ06-2AX0
• 8192 to 65536 PowerTags
6AV6 371-1BN06-2AX0
Complete packages
• 128 to 256 PowerTags
6AV6 371-1BD16-2AX0
• 128 to 1024 PowerTags
6AV6 371-1BE16-2AX0
• 128 to 8192 PowerTags
6AV6 371-1BK16-2AX0
• 128 to 65536 PowerTags
6AV6 371-1BF16-2AX0
• 256 to 1024 PowerTags
6AV6 371-1BG16-2AX0
• 256 to 8192 PowerTags
6AV6 371-1BL16-2AX0
• 256 to 65536 PowerTags
6AV6 371-1BH16-2AX0
• 1024 to 8192 PowerTags
6AV6 371-1BM16-2AX0
• 1024 to 65536 PowerTags
6AV6 371-1BJ16-2AX0
• 8192 to 65536 PowerTags
6AV6 371-1BN16-2AX0
1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station.
4/48
Siemens ST 80 · 2009
B) Subject to export regulations: AL: N and ECCN: EAR99S
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data (continued)
Order No.
Order No.
Communication via Industrial Ethernet
Communication via Industrial Ethernet (continued)
SOFTNET-S7 Edition 2007
S7-1613 Edition 2007
Software for S7 and S5-compatible communication, incl. OPC
server, PG/OP communication
and NCM PC; up to 64 connections, single license for 1 installation, runtime software, software
and electronic manual on
CD-ROM, license key on USB
stick, Class A, for 32-bit: Windows
XP Professional, Windows 2003
Server, VISTA Ultimate/Business;
for CP 1612; German/English
• Single license for 1 installation D
6GK1 704-1CW70-3AA0
Software for S7 and S5-compatible communication, incl. OPC
server, PG/OP communication
and NCM PC; up to 120 connections, single license for 1 installation, runtime software, software
and electronic manual on
CD-ROM, license key on USB
stick, Class A, for 32-bit:
Windows XP Professional,
Windows 2003 Server, Windows
VISTA Ultimate/Business;
for CP 1613, CP 1613 A2,
CP1623; German/English
• Upgrade package
for SIMATIC NET Edition 2006
6GK1 704-1CW00-3AE0
• Single license for 1 installation D
6GK1 716-1CB70-3AA0
6GK1 704-1CW00-3AE1
• Upgrade package
for SIMATIC NET Edition 2006
D
6GK1 716-1CB00-3AE0
• Upgrade package
for SIMATIC NET V6.0, V6.1,
V6.2 and Edition 2005
D
6GK1 716-1CB00-3AE1
• Upgrade package
for SIMATIC NET V6.0, V6.1,
V6.2 and Edition 2005
D
D
SOFTNET-S7 Lean Edition 2007
(included in the scope of
delivery of WinCC V7.0)
Communication via PROFIBUS
Software for S7 and S5-compatible communication, incl. OPC
server, PG/OP communication
and NCM PC; up to 8 connections, single license for 1 installation, runtime software, software
and electronic manual on CDROM, license key on USB stick,
Class A, for 32-bit: Windows XP
Professional, Windows 2003
Server, VISTA Ultimate/Business;
for CP 1612; German/English
6GK1 561-1AA01
CP 5611 A2
PCI card (32 bit) for connecting
a PG/PC to PROFIBUS (communications software included in the
WinCC basic package)
CP 5621
• Single license for 1 installation D
6GK1 704-1LW70-3AA0
• Upgrade package
for SIMATIC NET Edition 2006
D
6GK1 704-1LW00-3AE0
• Upgrade package
for SIMATIC NET V6.0, V6.1,
V6.2 and Edition 2005
D
6GK1 704-1LW00-3AE1
6GK1 161-3AA01
CP 1613 A2
Q
6GK1 162-3AA00
PCI Express card (32 bits) for
connecting a PG/PC to Industrial
Ethernet (communications software must be ordered separately)
T
6GK1 562-1AA00
A
6GK1 561-1AM01
T
6GK1 562-1AM00
PCI Express card (32-bit) for
connecting a PG/PC to
PROFIBUS (communications
software included in the WinCC
basic package)
CP 5611 MPI
Comprising CP 5611 A2 and
MPI cable, 5 m
CP 5621 MPI
Comprising CP 5621 (32-bit)
and MPI cable, 5 m
CP 5512
PCI card (32 bit) for the connection of PG/PC to Industrial Ethernet (communications software
must be ordered separately)
CP 1623
4
6GK1 551-2AA00
PCMCIA card (CARDBUS 32 bit)
for the connection of a PG/
notebook to PROFIBUS or
MPI (communications software
included in WinCC basic
package)
PC/MPI adapter
6ES7 972-0CA23-0XA0
RS 232, 9-pin; male with
RS 232/MPI converter,
max. 19.2 Kbit/s
CP 5613 A2
6GK1 561-3AA01
PCI card (32-bit) for connecting
a PC to PROFIBUS (communications software must be ordered
separately).
A) Subject to export regulations: AL: N and ECCN: EAR99H
D) Subject to export regulations: AL: N and ECCN: 5D992B1
Q) Subject to export regulations: AL: N and ECCN: 5A991X
T) Subject to export regulations: AL: 5A002A1A2 and ECCN: 5A002A1A2
Siemens ST 80 · 2009
4/49
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data (continued)
4
Order No.
Order No.
Communication via PROFIBUS (continued)
Communication via PROFIBUS (continued)
S7-5613 Edition 2007
FMS-5613 Edition 2007
Software for S7 Communication
incl. PG/OP protocol, FDL, OPC
server; runtime software, software and electronic manual on
CD-ROM, license key on USB
stick, Class A, for 32-bit: Windows
XP Professional, Windows 2003
Server, Windows VISTA Ultimate/Business; for CP 5613 A2;
German/English
Software for FMS protocol incl.
PG/OP communication, FDL,
OPC server, runtime software,
software and electronic manual
on CD-ROM, license key on USB
stick, Class A, for 32-bit: Windows
XP Professional, Windows 2003
Server, Windows VISTA Ultimate/Business; for CP 5613 A2;
German/English
• Single license for 1 installation D
6GK1 713-5CB70-3AA0
• Single license for 1 installation D
6GK1 713-5FB70-3AA0
• Upgrade package
for SIMATIC NET Edition 2006
6GK1 713-5CB00-3AE0
• Upgrade package
for SIMATIC NET Edition 2006
D
6GK1 713-5FB00-3AE0
6GK1 713-1CB00-3AE1
• Upgrade package
for SIMATIC NET V6.0, V6.1,
V6.2 and Edition 2005
D
6GK1 713-5FB00-3AE1
D
• Upgrade package
for SIMATIC NET V6.0, V6.1,
V6.2 and Edition 2005
DP-5613 Edition 2007
Hardware for process control functions
Software for DP protocol incl.
PG/OP communication, FDL,
OPC server, runtime software,
software and electronic manual
on CD-ROM, license key on USB
stick, Class A, for 32-bit: Windows
XP Professional, Windows 2003
Server, Windows VISTA Ultimate/Business; for CP 5613 A2;
German/English
DCF-77 receiver
for time synchronization
• DCF77 (Europe)
• GPS (worldwide)
2XV9 450-1AR14
H
2XV9 450-1AR13
• 2 screens
A
6ES7 652-0XX03-1XE0
• 4 screens
A
6ES7 652-0XX03-1XE1
Multi-VGA
• Single license for 1 installation D
6GK1 713-5DB70-3AA0
• Upgrade package
for SIMATIC NET Edition 2006
6GK1 713-5DB00-3AE0
D
• Upgrade package
for SIMATIC NET V6.0, V6.1,
V6.2 and Edition 2005
6GK1 713-1DB00-3AE1
A) Subject to export regulations: AL: N and ECCN: EAR99H
D) Subject to export regulations: AL: N and ECCN: 5D992B1
H) Subject to export regulations: AL: N and ECCN: 7A994A
Note:
For further information about process control options, see
Catalog ST PCS 7
■ More information
WinCC language versions
SIMATIC WinCC is also offered in simplified Chinese, traditional
Chinese, Korean and Japanese especially for Asian markets.
These WinCC versions are intended for machine manufacturers,
plant constructors and exporters who supply the regions of
China, Taiwan, Korea and Japan.
WinCC ASIA includes all familiar WinCC functions and offers in
addition the configuration user interface in the respective national language and English. The online Help is available in simplified Chinese, traditional Chinese, Korean, Japanese and English. A Chinese, Korean, Japanese or multilingual Windows
operating system is required for operation.
WinCC ASIA is delivered on a separate DVD which contains all
of the above mentioned language versions. The corresponding
documentation can be obtained from the national subsidiaries in
China, Korea, Taiwan and Japan.
4/50
Siemens ST 80 · 2009
The runtime licenses are language-neutral. The English handling
program (Automation License Manager – ALM) is executable
under the Chinese, Korean and Japanese Windows versions.
Additional information is available in the Internet under:
http://www.siemens.com/wincc
Separate configurators are available for PC hardware:
• SIMATIC Panel PC 577B
• SIMATIC Panel PC 677B (server operating system available
soon)
• SIMATIC Rack PC 547B (preconfigured also with server
operating systems)
• SIMATIC Rack PC 847B (preconfigured also with server
operating systems)
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC options
■ Overview
C
WinCtion
Op
C
WinCd-on
Ad
C
WinCis-SW
Bas C, RT
R
Options for IT and Business Integration – Plant Intelligence
• - WinCC/DataMonitor
- For display and analysis of current process states and
historical data on office PCs with standard tools
• WinCC/DowntimeMonitor
- For the detection and analysis of standstill times for
machines and systems
• WinCC/ProcessMonitor
- Management information system and quality analysis
• WinCC/Connectivity Pack
- Access to WinCC archive via OPC HDA, OPC A&E,
OPC XML Server and WinCC OLE-DB/OLE-DB
• WinCC/Connectivity Station
- Gateway to WinCC server data over OPC HDA, OPC A&E,
OPC XML server and WinCC OLE-DB /OLE-DB from
independent computers
• WinCC/IndustrialDataBridge
- Configurable link to databases and IT systems
C
WinCtion
Op
C
WinCd-on
Ad
C
WinCtion
Op
G_ST80_XX_00175
C
WinCd-on
Ad
• The universal WinCC basic software is the basis for modular
expansions. These functional expansions can be obtained in
the form of WinCC options and as WinCC Premium add-ons.
• WinCC options are created by WinCC Development and are
Siemens Industry Automation products. You can obtain
support from our Advisory Services and via the central hotline.
Options for scalable plant configurations
• WinCC/Server
- To set up a powerful client/server system
• WinCC/Web Navigator
- To control and monitor plants via the Internet, in-house intranet or LAN
• WinCC/Central Archive Server (CAS)
- For configuring a central archive server
Options for increasing the availability
• WinCC/Redundancy;
- For increased system availability through redundancy
• SIMATIC Maintenance Station
- For system-integrated diagnostics and system-based asset
management
• WinCC/ProAgent
- For reliable process diagnostics
Options for SCADA expansions
• WinCC/User Archives
- To manage data sets in user archives
Options for sector-specific expansions
• SIMATIC BATCH (for WinCC)
- WinCC in combination with the SIMATIC BATCH products
offers the solution for implementation of batch processes in
accordance with ISA S88.
- Batch processes which place heterogeneous demands on
the interfacing of different types of PLC, such as S7-400/300,
S5 and third-party PLCs, are automated using SIMATIC
BATCH (for WinCC).
• WinCC/ChangeControl
- Change and version management
- Generation of audit trails for engineering
• WinCC/Audit
- Change management
- Generation of audit trails for engineering and runtime
• SIMATIC Logon
- Central management of WinCC users, plant-wide
(to CFR 21 Part 11)
Options for individual system expansions
• WinCC/IndustrialX
- For the creation of customized WinCC ActiveX objects in
a VB development environment and .net.
• WinCC/ODK
- For the use of open programming interfaces
(Open Development Kit)
Options for comprehensive support
• WinCC/Comprehensive Support
- Extensive support package; contains current updates/
upgrades for WinCC basic software and options.
■ More information
WinCC options
Additional information is available in the Internet under:
http://www.siemens.com/wincc/options
Siemens ST 80 · 2009
4/51
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Server
■ Overview
Client
Client
Client
TERMINAL BUS TCP/IP
PROCESS BUS
G_ST80_XX_00005
4
• Option for SIMATIC WinCC, which permits the configuration
of a powerful client/server system
• One of the following operating systems must be available to
install the option on the server: Windows Server 2003 (for V6)
or Windows Server 2003 R2 (for V6.2). Up to 3 clients can be
connected when using Windows XP Professional.
• A number of coordinated HMI stations can be operated in a
single group with networked automation systems
• Client/server solution:
- One server can supply up to 32 connected clients with
process and archive data, messages, images and reports
- Depending on the size of the plant, up to 12 servers and
32 clients can be used
• Requirement: Network connection (TCP/IP) between the
server PC and the connected clients1)
• One license is required for each server.
1)
One of the following operating systems is installed on one WinCC
server:
Windows 2000 Server, Windows 2000 Advanced Server, Windows Server
2003 or Windows Server 2003 R2.
Up to 3 clients with Windows XP Professional.
■ Benefits
In a complex plant, WinCC can also be configured as a
distributed system according to requirements:
• Functional distribution (e.g. message servers, archive
servers, etc.) or
• Distribution according to the physical plant structure
(e.g. body-in-white, paintshop, etc.)
■ Function
Each client can access more than one server at a time. Clients
can also be used for configuration on the server.
A configuration of WinCC clients as a central Web server – as a
distributed system if required – with an overview of all server
projects in the system is also possible.
Only the smallest runtime license RT128 is required for the
clients, or if configuring is also to be handled on the client, the
smallest complete license RC128 is sufficient. This makes it
possible to configure inexpensive operator and configuration
stations in a network.
■ Ordering data
• Plant-wide scalability from the single-user system to the
client/server solution
• Significantly higher quantity framework, relieving the individual servers and better performance due to distributing the
complete application or tasks over several servers
• Low-cost configuration on the client is possible (the minimum
RC license is sufficient)
4/52
■ Application
Siemens ST 80 · 2009
Order No.
WinCC/Server
• for WinCC V7.0
6AV6 371-1CA07-0AX0
• for WinCC V6.2
6AV6 371-1CA06-2AX0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Web Navigator
■ Overview
4
• Option for SIMATIC WinCC for operator control and monitoring
of plants via the Internet, in-house intranet or LAN
• Configuration from:
- a Web server with the SIMATIC WinCC software as a singleuser, client or server version and a Web client that enables
operator control and monitoring of a current WinCC project
via an Internet browser with ActiveX support. The WinCC basic system does not have to be installed on the client
computer
• Licensing:
- A license is required in order to use the Web Server.
- Licenses are available for access to the Web Server by 3,
10, 25 or 50 clients.
- Low-cost Web Navigator Diagnostics licenses are available
for remote diagnostics via a number of distributed Web
Servers.
Highlights:
• Installation of the Web Server – in distributed systems – also
on a WinCC Client;
- Access to up to 12 subordinate WinCC stations (servers)
possible
- Web Clients offer common views of data on various WinCC
Servers
- If you are using WinCC/Redundancy, the Web Clients will
also transfer via the subordinate WinCC Servers (requires
WinCC Client running as Web Server).
- Separating the Web functionality from the WinCC data
servers makes the overall system safer and more scalable in
respect of load. Integrated user management with
WinCC V6:
The configured WinCC operator authorizations are taken into
account on the Web Client.
• Access to user archives
• VB scripts are supported in the same way as the new objects
and RT functions in WinCC V6
• User-friendly services and tools for distributing customized
objects (controls, files) to Web Clients can be supplied for use
as an integration platform. These components can then also
be integrated into cross-Web/Server navigation.
• Distribution of load across a number of Web Servers in order
to run several hundred Web Clients in a single system; Web
Clients are distributed across Web Servers automatically.
Siemens ST 80 · 2009
4/53
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Web Navigator
■ Benefits
4
■ Application
• Operator control and monitoring across long distances and on
different platforms (PC, local panel, mobile PDA)
• Large configurations with up to 50 operator stations
• Fast updating rates thanks to event-driven communication
• Optimally tailored clients for operating and monitoring,
analysis, service and diagnostics
• Acceptance of configuration data for the web, generally
without changes
• Minimum maintenance costs thanks to centralized software
administration
• High security standards and availability
- Increased security due to separation of WinCC server and
web server (web server in secure environment)
- Support for commonly used security mechanisms (routers,
firewalls, proxy servers)
- Access authorization and user administration
Innovations of V7.0
• Version 7 supports Microsoft Internet Explorer Version 7.0,
including tabbed browsing. A new license is not required for
separate tabs.
• With the WinCC Web Viewer, the process screens can be
displayed on the Web Client independently of the Internet
Explorer. Settings for the client are made on the client itself.
- Address, user name and password.
- Runtime language, disable keys, hotkey property sheets.
- Start screen, menu and toolbars, Windows attributes.
- Activate monitor keyboard, <Ctrl> <ALT> <DEL>, automatic
logout.
• The WinCC Web Viewer can also be used in conjunction with
the MS Terminal Service.
• The Web Navigator client can also be used over WLAN with
the Panel PC 12. (Recommended hardware: Scalance
W788-1PRO Access Point, Scalance W746-1PRO Ethernet
Client Module).
• From version 7 on, the web navigator can also be operated in
"view only" mode and is thus used as tool for operating and
navigating only via WinCC screens by means of Internet
Explorer.
• The cursor for View only mode can be selected according to
individual requirements.
• Web server logins and logouts are recorded in the alarm and
audit archive.
• There is a gadget available for the VISTA operating system
in which selected WinCC process screens can be displayed.
The gadget does not require any additional Web Navigator
license. The Web Navigator server can be selected direct
using the gadget.
• Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
• Runtime in the web client can be terminated by means of
scripting.
4/54
Siemens ST 80 · 2009
Apart from the typical application of the Web Navigator in the
WAN field (Wide Area Network), the Web Navigator can also be
used for extremely cost-effective solutions. This particularly
includes applications that have a widely distributed structure
(water/sewage, oil and gas), or in which there is only sporadic
accessing of process information (buildings management).
The Web Navigator also supports vertical integration, i.e. a
networked IT landscape with company-wide data flow between
the planning and operational levels of a company. The only tool
that is required for direct access to up-to-date process information is a standard browser.
The Web server can have its own direct process connection.
Alternatively coupling is possible by means of OPC or a Web
server subordinate to a WinCC client. This not only increases
reliability, but also reduces the data traffic within the system.
In addition to the standard Web navigator license, a so-called
diagnostics client exists which basically has the same functions
but which is particularly suitable for the following applications:
• Remote diagnostics/operation by several unmanned WinCC
stations
• Central control rooms with multiple Web server support
through a single user interface
• Power users who require guaranteed access to the server at
any time, regardless of how many users are already logged on
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Web Navigator
■ Design
Licenses for the Web Navigator
The Web Navigator Client software can be installed as many
times as required without the need for a license.
• Server-based licensing;
a license is required in order to use the Web Navigator Server.
Licenses are available for simultaneous access to the Web
Server by 3, 10, 25 or 50 clients.
• Diagnostics client licensing;
for optimum-cost access by one or a small number of Web
Navigator Clients to numerous Web Servers (e.g., for the
purpose of diagnostics). This client license provides guaranteed access to Web Servers at any time. In respect of function
there is no difference compared with regular Web Navigator
Clients and the two can be mixed.
Web Navigator Clients can:
• Access a number of different Web servers or
• Access data on a number of higher-level WinCC stations
simultaneously via a remote Web server
■ Function
The Web Configurator (Wizard) makes setting up and configuring a Web Navigator Server very easy. WinCC process screens
to be visualized via the Internet are created as usual using
WinCC Graphics Designer. Under normal circumstances the
project can be worked on locally without modification. The Web
Publishing Wizard optimizes the screens for transmission and
display on the Internet. A standard browser is all that is required
to display WinCC process screens on the Web Client. The MS
Internet Explorer is used depending on the Web Navigator version used (tip: start the Internet Explorer in full-screen mode with
the start parameter "-k").
The operator on the Web Client is integrated in the central
WinCC user administration and can operate and monitor the
system according to the configured access rights. The Web
Navigator supports all standard security mechanisms that can
be used for applications on the Internet, e.g. routers, firewalls
and proxy servers.
On the server side, only one Web Navigator Diagnostics Server
license or, alternatively, one Standard Web Navigator license is
required.
Alternatively, a number of Web Navigator Servers with the same
WinCC project can be combined to create a "server farm". This
means that it is possible for several hundred Web Clients to have
access to the same database. The service ensures that the
clients accessing are distributed evenly across all servers. If a
server fails the Web Client is automatically forwarded to the next
available server.
In order to use this functionality you will need to install a Web
Load Balancing license on the Web Servers involved. Each Load
Balance package contains 2 licenses.
An inexpensive expansion option for Web Load Balancing is
available for redundant WinCC stations on which the Web
Navigator is also installed. For this purpose, you need to install
a Web Load Balancing Step Up license on the web servers
involved. Each Step Up package contains 2 licenses.
Thin Client solutions
The Web Navigator can also run under Windows 2003 terminal
services. A Windows 2003 Server (or higher) operating system
is required. This makes it possible to connect SIMATIC Thin
Clients as visualization stations to WinCC, for example.
For this purpose, the Windows terminal services must be
installed on the PC on which the Web Client is installed. A
Windows 2003 Server (or higher) operating system is required.
Up to 25 Thin Clients can be connected to one terminal server.
Applications:
• Mobile devices
• Handhelds
• Rugged on-site visualizations
Hybrid configuration
WebNavigator and DataMonitor Clients can be mixed in a single
system.
Siemens ST 80 · 2009
4/55
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Web Navigator
■ Ordering data
Order No.
WinCC/Web Navigator V7.0;
for WinCC V7.0
• Base Pack (3 client licenses)
6AV6 371-1DH07-0AX0
• 10 client licenses
6AV6 371-1DH07-0BX0
• 25 client licenses
6AV6 371-1DH07-0CX0
• 50 client licenses
6AV6 371-1DH07-0DX0
WinCC/Web Navigator
PowerPacks V7.0
4
• From 3 to 10 clients
6AV6 371-1DH07-0AB0
• From 10 to 25 clients
6AV6 371-1DH07-0BC0
• From 25 to 50 clients
6AV6 371-1DH07-0CD0
WinCC/Web Navigator
Diagnostics Client
• for WinCC V7.0
6AV6 371-1DH07-0EX0
WinCC/Web Navigator
Diagnostics Server
• for WinCC V7.0
Order No.
WinCC/Web Navigator
(continued)
V6.2 SP2 ASIA;
for WinCC V6.2 SP2 ASIA
• Base Pack (3 client licenses)
6AV6 371-1DH06-2AV0
• 10 client licenses
6AV6 371-1DH06-2BV0
• 25 client licenses
6AV6 371-1DH06-2CV0
• 50 client licenses
6AV6 371-1DH06-2DV0
WinCC/Web Navigator
PowerPacks
V6.2 (for ASIA variants as well)
• From 3 to 10 clients
6AV6 371-1DH06-2AB0
• From 10 to 25 clients
6AV6 371-1DH06-2BC0
• From 25 to 50 clients
6AV6 371-1DH06-2CD0
WinCC/Web Navigator
Diagnostics Client
6AV6 371-1DH07-0FX0
WinCC/Web Navigator Upgrade
V6.0 to V7.0
• for WinCC V6.2 SP2
6AV6 371-1DH06-2EX0
• for WinCC V6.2 SP2 ASIA
6AV6 371-1DH06-2EV0
• For 3 clients
6AV6 371-1DH07-0AX4
WinCC/Web Navigator
Diagnostics Server
• For 10 clients
6AV6 371-1DH07-0BX4
• for WinCC V6.2 SP2
• For 25 clients
6AV6 371-1DH07-0CX4
for WinCC V6.2 SP2 ASIA
• For 50 clients
6AV6 371-1DH07-0DX4
WinCC/Web Navigator Upgrade
V1.x on V6.2 SP2
V6.2 to V7.0
• For 3 clients
• For 10 clients
• For 25 clients
• For 50 clients
6AV6 371-1DH07-0AX3
6AV6 371-1DH07-0BX3
6AV6 371-1DH07-0CX3
6AV6 371-1DH07-0DX3
• For Web Navigator Diagnostics
Client
6AV6 371-1DH07-0EX4
• For Web Navigator Diagnostics
Server
6AV6 371-1DH07-0FX4
WinCC / Web Load Balancing
V7.0
6AV6 371-1DH06-2FV0
• For 3 clients
6AV6 371-1DH06-2AX4
• For 10 clients
6AV6 371-1DH06-2BX4
• For 25 clients
6AV6 371-1DH06-2CX4
• For 50 clients
6AV6 371-1DH06-2DX4
• For 3, 10, 25, 50 clients1)
6AV6 371-1DH06-2XX3
• For Web Navigator Diagnostics
Client
6AV6 371-1DH06-2EX3
• For Web Navigator Diagnostics
Server
6AV6 371-1DH06-2FX3
V6.x ASIA to V6.2 SP2 ASIA
• Load Balancing
6AV6 371-1DH07-0JX0
• For 3, 10, 25, 50 clients1)
• Load Balancing Step Up
6AV6 371-1DH07-0FJ0
WinCC / Web Load Balancing
V6.2
WinCC/Web Navigator
V6.2 SP2;
for WinCC V6.2 SP2
• Base Pack (3 client licenses)
6AV6 371-1DH06-2AX0
• 10 client licenses
6AV6 371-1DH06-2BX0
• 25 client licenses
6AV6 371-1DH06-2CX0
• 50 client licenses
6AV6 371-1DH06-2DX0
B) Subject to export regulations: AL: N and ECCN: EAR99S
incl. upgrade for diagnostics client, diagnostics server, Load Balancing
and Load Balancing StepUp
4/56
6AV6 371-1DH06-2FX0
V6.x on V6.2 SP2
V6.x to V7.0
1)
B
Siemens ST 80 · 2009
6AV6 371-1DH06-2XV3
• Load Balancing
6AV6 371-1DH06-2JX0
• Load Balancing Step Up
6AV6 371-1DH06-2FJ0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Web Navigator
■ More information
System requirements – web server
System requirements – web client
For WinCC/Web Navigator V 7.0
• Windows Vista (Business, Enterprise and Ultimate)
• Windows XP Professional Service Pack 2 (max. 3 clients)
• Windows Server 2003 SP2 and Windows Server R2 SP2
• Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer
V7.0.
• Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)
• WinCC basic system V7.0
For WinCC/Web Navigator V7.0
• Windows Vista (Business, Enterprise and Ultimate)
• Additional operating systems include Microsoft Windows Vista
32bit HomeBasic and HomePremium
• Windows XP Professional Service Pack 2 (max. 3 clients)
• Windows Server 2003 SP2 and Windows Server R2 SP2
• Windows Server 2003 terminal services
• Windows XP embedded (only when using Panel PC 477)
• Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer
V7.0
For WinCC/Web Navigator V6.2 SP2
• Windows 2000 Professional Service Pack 4 (max. 3 clients)
• Windows XP Professional or Service Pack 2 (max. 3 clients)
• Windows Server 2003 SP2 or Windows Server 2003 R2 SP2
• Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)
• Microsoft SQL Server 2005 SP1 (scope of supply of WinCC)
• WinCC basic system V6.2 SP2
For WinCC/Web Navigator V6.2 SP2
• Windows XP Professional Service Pack 2
• Windows 2000 Professional Service Pack 4
• Windows Server 2003 SP2 or Windows Server 2003 R2 SP2
• Windows Server 2003 terminal services
• Windows XP embedded (only when using Panel PC 477)
• Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)
WinCC Web Navigator V6.2 SP2 ASIA
(requires SIMATIC WinCC V6.2 SP2 ASIA)
The functions included in this version differ from the standard
version of WinCC/Web Navigator V6.2 SP2 as follows:
• This version does not allow an Asian Web Navigator client to
access a non-Asian server and vice versa.
Siemens ST 80 · 2009
4/57
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Central Archive Server (CAS)
■ Overview
■ Ordering data
Central data management, reliable, high-performance archiving
and central backup mechanisms form the basis of a Process
Historian solution: Integration in the SCADA world, data interfaces for access to archived data and analysis functions are the
component parts.
The option CAS was designed for this purpose and is used to
export the archived data of all servers in the system to a computer and manage it. Integration of CAS in the WinCC world
means that the data remains available for the WinCC clients as
well as for the WinCC standard interfaces.
WinCC/CAS contains all licenses for the central archive server
including 1500 archive tags. The number of archive tags can be
increased to 120000 using PowerPacks or further WinCC
archives.
4
■ Benefits
• Central data management of all archived alarms and process
values
• Integrated back-up system for the archive data
• Transparent access to the data from all WinCC clients and
over the open interfaces
• Integrated Web viewer for analyzing data
■ Function
Both the process value archive and alarm log are created on the
separate WinCC servers and transferred to CAS when individual
database segments have been closed.
With "Store&Forward", when the network is interrupted between
the WinCC server and CAS, data will be reliably transferred as
soon as the network is operating again.
Data access is transparent for display and analysis and is still
possible through the standard WinCC clients. For the clients, it
is of no consequence whether the data are on the WinCC server
or already on CAS. Data saved in CAS can also be viewed using
the Web viewer included in the package.
The data of the distributed WinCC system can also be accessed
through the familiar interfaces (OPC DA, OPC A&E, OPC HDA
and Ole-DB) with the help of the Connectivity Pack or the
Connectivity Station. In this manner, the data saved in CAS can
be efficiently transferred to higher-level systems or used for the
purposes of analysis.
4/58
Siemens ST 80 · 2009
Order No.
WinCC/CAS V7.0 basic
packages
• WinCC/CAS V7.0
6AV6 371-1DQ17-0XX0
WinCC/CAS upgrade
• V6.2 to V7.0
6AV6 371-1DQ17-0XX3
WinCC/CAS V6.2 SP2 basic
packages
• WinCC/CAS V6.2 SP2
6AV6 371-1DQ16-2XX0
• WinCC/CAS V6.2 SP2 ASIA
6AV6 371-1DQ16-2XV0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Redundancy
■ Overview
• Option for SIMATIC WinCC, supporting the parallel operation
of two interfaced WinCC single-user systems or process data
servers for mutual monitoring
• If one of the two server PCs or one of the two WinCC stations
fails, the second one will take over control of the entire system.
Once the failed server or station is restored to operation, the
content of all the message and process value archives are
copied to it.
• One WinCC/Redundancy package is required for each redundant pair of servers.
:LQ&&
&OLHQWV
/$1
:LQ&&
6HUYHUV
■ Benefits
352),1(7
*B67B;;B
352),%86
• Increased system availability with continuous data integrity
• Automatic changeover of client in the event of failure of a
server or failure of the communication to a server
• Continuous operator control and visualization thanks to
automatic client changeover to the intact server
• Automatic updating of all archives in the background after
rectification of the fault
■ Function
Normally, two WinCC stations or process data servers run in
parallel. Each station has its own process connection and its
own data archives. WinCC/Redundancy ensures automatic
matching of system and user archive data.
:LQ&&
&OLHQWV
If one of the two server computers or WinCC stations fails, the
second will take over the archiving of messages and process
data, thereby ensuring seamless data integrity. In client/server
mode, the clients are automatically switched from the failed
server to the redundant partner. This ensures continuous plant
visualization and operation on every operator station.
/$1
:LQ&&
6HUYHUV
When the failed partner resumes operation, all process values,
messages and data archived during the fail period are automatically matched with the partner. This process runs in the background and does not affect plant continuity. Once this is complete, two equivalent servers/stations will be available again.
352),1(7
*B67B;;B
352),%86
Communication with the SIMATIC S7 PLC can also be configured with redundancy (an H Series SIMATIC S7 is required) by
plugging in two communication modules and configuring two
communication paths (S7-REDCONNECT software package).
The use of failsafe H Series SIMATIC S7 PLCs can, if required,
further increase availability at control level.
■ Ordering data
Order No.
WinCC/Redundancy
:LQ&&
&OLHQWV
• for WinCC V7.0
6AV6 371-1CF07-0AX0
• for WinCC V6.2
6AV6 371-1CF06-2AX0
/$1
:LQ&&
6HUYHUV
352),1(7
*B67B;;B
352),%86
Siemens ST 80 · 2009
4/59
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC Maintenance Station
■ Overview
■ Benefits
4
System-integrated plant asset management system
• Automatic generation of a maintenance view in WinCC from
the STEP 7 hardware configuration
• Plant-wide visualization of all automation components from the
management level to the field level in ready linked,
hierarchically arranged WinCC displays
• Mapping of central and distributed SIMATIC S7 components,
PROFIBUS and PROFINET networks as well as associated
bus nodes
• Ethernet network components and industrial PCs can be
integrated through SIMATIC NET SNMP OPC Server
• Display of device status with group status generation in
overview and detail displays
• The device statuses "Maintenance required" and
"Maintenance request" are supported for status-based
maintenance
• Provision of uniform faceplates showing detailed information
for all components displayed
• Display of the device identification data (electronic rating
plate)
• Integrated display of the status of the request
4/60
Siemens ST 80 · 2009
• Reducing down times:
- problems in the plant are detected sooner due to the uniform
presentation and clear overview of all information that is important for maintenance.
• Avoiding downtimes:
- support of condition-based maintenance.
• Reduced maintenance costs:
- optimization of the flow of information between production
and maintenance by submitting maintenance requests and
presenting the status of requests.
• Transparency and traceability:
- all procedures are based on messages and can therefore be
archived and traced.
- a comprehensive database is generated that can be analyzed with WinCC functions or external tools.
• Scalability:
- support of WinCC single-user stations and client/server
configurations.
- the SIMATIC Maintenance Station can be added to an
existing WinCC project.
• Consistency:
- The maintenance view is generated from the control project
and is consistent with it.
• Flexibility in selection of devices:
- use of the PROFIBUS and PROFINET standards for device
interfacing.
- an additional proxy concept allows devices to be displayed
that are not included in the STEP 7 hardware configuration
or that do not support the standard diagnostics of
PROFIBUS/PROFINET.
■ Application
The SIMATIC Maintenance Station is a tool for the diagnosis and
maintenance of machines and plants. This is an option package
for STEP 7 V5.4 and WinCC V6.2 or V7.0 that generates a WinCC
maintenance view for a STEP 7 project/multiproject.
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC Maintenance Station
■ Design
The SIMATIC Maintenance Station is available in various
different packages:
• Basic package:
Contains all the tools needed to configure a Maintenance
Station and a license for the display of 100 devices.
• Powerpacks:
For larger quantities, powerpacks are available with licenses
for 100, 500 or 1000 devices. These can be added to the
existing licenses and can be combined as required.
In this context, devices can be:
• AS systems
• Distributed devices (PROFIBUS / PROFINET)
• PCs
• Network components
• Asset proxies
Requirements for configuring a SIMATIC Maintenance
Station
• STEP 7 license (V5.4 upwards)
• WinCC RC license (V6.2 or V7.0)
• The SIMATIC NET licenses required for the plant configuration
Requirements for operation of a SIMATIC Maintenance
Station
• The WinCC licenses (V6.2 or V7.0) complying with the plant
configuration
■ Function
Hierarchic visualization of plant components in WinCC
• Generation of a WinCC picture tree for hierarchic display of
the plant components.
• Automatic creation and linking of displays, equipment symbols, status indicators, faceplates and the required variables.
• Presentation of the detailed data in faceplates with selectable
views.
• Easy navigation in the plant using the WinCC Picture Tree
Manager.
• Generated pictures can be enhanced using the WinCC
Graphic Designer.
• Switchover between a WinCC SCADA project and the picture
tree of the SIMATIC Maintenance Station can be configured
using standard WinCC functions.
Display of the current status of the plant and its components
• Clearly understandable status displays through the use of
uniform symbols.
• Display of no-fault status, fault, maintenance requirement and
maintenance request
• Display of status of request for submitted repair requests.
• Display of order status.
• Display of the alarm status of the components.
Display of the identification data of the plant components
• Display of the identification data available for a device in the
faceplate for the device.
• Automatic loading of the data available in the configuration
into the maintenance station.
• Reading of the "Identification & Maintenance functions
(I&M1))" in accordance with the PROFIBUS International
specification.
• Export2) of I&M data for all devices in the form of an XML file.
Displaying alarms
• Loading of system error messages from STEP 7. STEP 7
provides the messages in 5 languages3), translation into
additional languages is possible in STEP 7.
• Display of the most recent message in a message line.
• Presentation of the active/archived messages of the selected
device in the faceplate.
Calling the STEP 7 hardware configuration
• The STEP 7 hardware configuration can be opened for a
selected device using a button in the faceplate. STEP 7 and
the project must be installed on the maintenance station for
this purpose.
1)
The Maintenance Station 2007 supports reading of I&M data for
PROFIBUS devices with C1 channel access.
2)
The I&M data loaded from the configuration are exported.
3)
For Siemens components that are included in the STEP 7 hardware catalog.
In the case of components that are integrated in STEP 7 using GSD files,
the GSD files must support the relevant languages.
Siemens ST 80 · 2009
4/61
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC Maintenance Station
■ Technical specifications
Hardware requirements
System
Clock frequency
Main memory
Free hard disk space
Engineering station
2.8 GHz
1 GB
15 GB
Maintenance Station Stand-alone /
WinCC-Station "Single-user Workstation"
2.8 GHz
1 GB
15 GB
Maintenance Station Server /
WinCC Server
2.8 GHz
1 GB
15 GB
Maintenance Station Client /
WinCC Client
2.8 GHz
512 MB
3 GB
Software requirements
4
System
Operating system
Engineering station "ES"
Windows XP Professional SP2
Windows Server 2003 SP1
Maintenance Station Stand-alone /
WinCC-Station "Single-user
Workstation"
Windows XP Professional SP2
Windows Server 2003 SP1
ES with Maintenance Station
Stand-alone
Windows XP Professional SP2
Windows Server 2003 SP1
Maintenance Station Server /
WinCC Server
Windows Server 2003 SP1
Maintenance Station Client /
WinCC Client
Windows XP Professional SP2
Windows Server 2003 SP1
Requirements for the integration of devices
Type
Integration
Comment
SIMATIC S7 controllers /
I/O
• S7-300 1)
Yes
• S7-400
Yes
• WinAC
Yes
Distributed devices
• ET 200
Yes
PROFIBUS DP and PROFINET IO according to STEP 7
hardware catalog
• PROFIBUS standard slaves
Yes
Integration using a GSD file
• PROFINET standard devices
Yes
Integration using a GSD file
Ethernet network components
Yes
SIMATIC NET SNMP OPC Server and MIB also
required
PROFINET network components
Yes
PROFIBUS diagnostic repeater
Yes
Network components
Personal Computer
PC/Industrial PC
Yes
SIMATIC NET SNMP OPC Server also required
Drives with PROFIBUS connection
Yes
For integrating devices designed to the PROFIDRIVE
profile, Drive ES SIMATIC (V5.4 SP1 or higher) is
required
Drives with PROFINET connection
Yes
For integrating devices designed to the PROFIDRIVE
profile, Drive ES SIMATIC (V5.4 SP1 or higher) is
required
Yes
Integrated via function block (asset proxy)
Drives
Accessory devices
Devices not configured in STEP 7
Hardware Config
1)
With S7-300, PROFIBUS/PROFINET systems are supported if they are
connected to the internal CPU interfaces
4/62
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC Maintenance Station
■ Ordering data
Order No.
SIMATIC Maintenance Station
2007 SP1
Software for implementation of
a plant-oriented asset management system
Basic package
with engineering software
(Floating License) and Runtime
License for 100 devices
D
6ES7 840-0WD00-0YA0
Powerpack 100
Runtime License for 100
additional devices
D
6ES7 840-0WD10-0YD0
Powerpack 500
Runtime License for 500
additional devices
D
6ES7 840-0WD20-0YD0
Powerpack 1000
Runtime License for 1000
additional devices
D
6ES7 840-0WD30-0YD0
Basic demo package 2007 SP1
D
6ES7 840-0WD00-0YA7
4
D) Subject to export regulations: AL: N and ECCN: 5D992B1
Siemens ST 80 · 2009
4/63
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/ProAgent
■ Overview
■ Ordering data
Order No.
SIMATIC WinCC/ProAgent
• V6.0 SP4; for WinCC V7.0 and
V6.2
6AV6 371-1DG06-0EX0
SIMATIC WinCC/ProAgent Upgrade
• to SIMATIC WinCC/ProAgent
V6.0 SP4
6AV6 371-1DG06-0EX4
Note:
For further details, see "SIMATIC ProAgent process diagnostics
software".
3B67B;;B
67(3
4
• Precise and rapid process fault diagnostics in plants and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various SIMATIC
components
• No further configuration for diagnostics functionality
• Reduces PLC memory and processor usage
4/64
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/DataMonitor
■ Overview
• The WinCC/DataMonitor is a component of WinCC Plant
Intelligence and is used for displaying and evaluating current
process statuses and historical data on office PCs with standard tools such as Microsoft Internet Explorer or Microsoft
Excel. The DataMonitor Client is supported by a web server
with current and historic process data and alarms. All staff
ranging from machine operators to corporate managers can
use the DataMonitor to obtain information.
• DataMonitor is a suite of Internet-capable tools:
- Process Builder – Tool for simple visualization and navigation
through WinCC screens using Internet Explorer (view only)
- Trends and Alarms – Internet Explorer-based display tool
(tables and graphs) for WinCC archive as well as for
relocated data
- Excel Workbooks – Protocol tool that integrates WinCC
archives and online values into MS Excel and supports
online analysis
- Published Reports – Event- or time-driven execution of Excel
or PDF reports for the output of process data and analysis
results
- Web center – Individual configuration of Internet pages and
summary of information within a portal in terms of WinCC
applications
• DataMonitor does not require manual client installation because it loads the required components from the web server.
Additional administration is unnecessary as a result.
• There is no installation required on the client for the Webcenter, Trends and Alarms functions.
• Licenses for simultaneous access by 1, 3, 10, 25 or 50 DataMonitor clients. Any combination of DataMonitor and Web
Navigator licenses can be used for an application.
■ Benefits
• Information can be compiled online individually during
runtime via the Internet/intranet.
• Efficiently monitor and analyze production lines.
- Display and evaluation of current process states and historical data on remote office PCs with standard tools such as
Microsoft Internet Explorer or Excel.
- Easy access to production data via the intranet or Internet
- Quick ascertainment of the production situation
- Use of standard products
• Easily collect and distribute information.
- Automated report creation
- No additional configuration effort through direct use of images from the WinCC project
- No training required for standard products
- Easy exchange of configuration data
• Substantiate decisions with reports.
- Evaluation via ready-made templates for special analyses of
the business processes (e.g. reports, statistics)
- Make bottlenecks transparent
- Individual views for user and situation
- Relative and absolute timeframe for information generation
• View production status anywhere and anytime.
- Individual views of information in production
- View the process and system operation
- Historical data can be compiled online individually
Highlights
• Access to the lower-level servers when installing the
DataMonitor server on a WinCC Client with separate project.
• Tag logging archive tags can be accessed by means of the
web center function without changing the WinCC
configuration system.
• Installation of the DataMonitor web center function on a
WinCC file server
Connections to
• Dedicated Internet pages can be created for displaying the
data. For this purpose, the following tools which can be
integrated in the Internet sites are available.
- Bar diagram, pie chart, trend curve display
- Process value table and statistics functions for the process
values
- Alarms, hit list for alarms
- Message text display for individual message texts, message
display, selection list of created reports
- Links to internal and external pages
- Display of graphics in jpg format
- Visualization of the WinCC process screens without installation download
• The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
• Reports generated with Excel or the WinCC Report Designer
can be made available on the DataMonitor server or e-mailed
automatically to the relevant group of people.
• Connections can be established to WinCC Runtime, the
central archive server, and swapped-out archives
Siemens ST 80 · 2009
4/65
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/DataMonitor
■ Benefits (continued)
4
Innovations of V7.0
• DataMonitor
- Supports Internet Explorer V 7.0 including tabbed browsing.
- The Client is enabled for VISTA Home Basic and Home
Premium.
- User-friendly web interface for all DataMonitor functions.
• DataMonitor/ProcessScreens
- The cursor for the "view only" mode can be selected as
required.
• DataMonitor/Web center
- Enhanced user management for the web center in order to
assign individual Internet pages and created reports to
specific user groups.
- Integrating WinCC process screens on Internet pages
without installation download
- Representation of preprocessed process data
- A search function facilitates the management of connections
to the WinCC Server.
- Swapped out archives can be connected and evaluated in
the DataMonitor web center.
- Automatic pre-assignment of the colors for representation in
the value display tools.
- Web center pages possible via pull-down box or list.
- Expansion of the display area (MenuHide function)
- Layout, web center pages can be deleted.
• DataMonitor/Reports
- Excel reports created offline can be loaded onto the
DataMonitor server and are thus available to selected user
groups.
■ Function
• All tools are fully Internet-compatible and, therefore, support
access via any type of connection (LAN, GSM, radio, modem,
Internet, etc.)
• All popular security mechanisms such as login/password,
firewalls, encryption, etc. are supported
• Users can combine the available tools at will. Licensing only
takes into account simultaneous access to one Web server
• For display purposes, screens from the WinCC project can be
used or special overview displays configured. Animations,
scripts, navigation and access rights remain valid
• The WinCC/DataMonitor supports a display function only
(local access to the process sequence is prevented)
• Company-wide Excel reports, which contain historical and
current process values, can be stored centrally for general
access (reports, statistics). However, local queries to meet
individual requirements can be compiled and executed
online. Plot and tabular representation are supported for
archive data already swapped out
• Created reports can be planned so that they are automatically
distributed by email after creation
• Pre-made elements make the assembly of individual web
pages easier for evaluating information
• Individual information compilation on one or more Internet
pages with the option of branching to other detail pages
• Pre-made Internet pages for trend and alarm display enable
an ad-hoc entry to Internet data evaluation
• An higher-level navigation feature provides a common
framework for the various tools
4/66
Siemens ST 80 · 2009
■ Ordering data
Order No.
WinCC/DataMonitor V7.0 for
WinCC V7.0
• 1 client license
6AV6 371-1DN07-0LX0
• 3 client licenses
6AV6 371-1DN07-0AX0
• 10 client licenses
6AV6 371-1DN07-0BX0
• 25 client licenses
6AV6 371-1DN07-0CX0
• 50 client licenses
6AV6 371-1DN07-0DX0
WinCC/DataMonitor
PowerPacks V7.0
• From 1 to 3 clients
6AV6 371-1DN07-0LA0
• From 3 to 10 clients
6AV6 371-1DN07-0AB0
• From 10 to 25 clients
6AV6 371-1DN07-0BC0
• From 25 to 50 clients
6AV6 371-1DN07-0CD0
WinCC/DataMonitor, Upgrade
• from V6.0 to V7.0
6AV6 371-1DN07-0XX4
• from V6.2 to V7.0
6AV6 371-1DN07-0XX3
• from V6.x to V6.2 SP2
6AV6 371-1DN06-2XX3
• from V6.x ASIA to V6.2 SP2
ASIA
6AV6 371-1DN06-2XV3
WinCC/DataMonitor V6.2 SP2
for WinCC V6.2 SP2
• 1 client license
6AV6 371-1DN06-2LX0
• 3 client licenses
6AV6 371-1DN06-2AX0
• 10 client licenses
6AV6 371-1DN06-2BX0
• 25 client licenses
6AV6 371-1DN06-2CX0
• 50 client licenses
6AV6 371-1DN06-2DX0
WinCC/DataMonitor V6.2 SP2
ASIA for WinCC V6.2 SP2 ASIA
• 1 client license
6AV6 371-1DN06-2LV0
• 3 client licenses
6AV6 371-1DN06-2AV0
• 10 client licenses
6AV6 371-1DN06-2BV0
• 25 client licenses
6AV6 371-1DN06-2CV0
• 50 client licenses
6AV6 371-1DN06-2DV0
WinCC/DataMonitor,
PowerPacks V6.2
• From 1 to 3 clients
6AV6 371-1DN06-2LA0
• From 3 to 10 clients
6AV6 371-1DN06-2AB0
• From 10 to 25 clients
6AV6 371-1DN06-2BC0
• From 25 to 50 clients
6AV6 371-1DN06-2CD0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/DowntimeMonitor
■ Overview
The entry point to SIMATIC Plant Intelligence can be through
options for the SIMATIC WinCC process visualization system.
The WinCC/DowntimeMonitor is a component of WinCC Plant
Intelligence and is used for monitoring the efficiency and performance of individual machine modules, subsystems and production lines. The combined elements to be monitored are designated as equipment. Using the WinCC/DowntimeMonitor, the
machine data management software, standstill time can be
recorded and analyzed centrally in production. For individual
devices, machines or entire production lines, the specific
parameters can be determined this way. Integration into WinCC
ensures complete transparency of all machine and plant data as
a basis for optimizing the plant’s productivity.
■ Benefits
• Recording failure times, localizing causes and reasons for
failure times, and monitoring of equipment efficiency.
• Weak-point analysis in production processes and recording of
undesirable process activities.
• Basis for decision making based on performance indicators.
• Identification of the events that lead to cost-intensive failures.
• Entry point for an extended downtime analysis with upgrade
options in the MES software SIMATIC IT.
• Identification of speed and quality losses.
• Complete transparency for all machines as basis for
optimizing the plant’s productivity. Faults and bottlenecks
are prevented to increase availability.
• Derivation of specific parameters (KPI - Key Performance
Indicators).
• Integration of respective display instruments (controls) in
WinCC process images.
• Can be utilized for individual machines or even complete
production plants.
• Distribution of evaluations to various people over the web.
The process values are read directly from WinCC and are
connected with the respective analysis function.
• The SIMATIC WinCC DowntimeMonitor can be installed on a
WinCC single station, WinCC Server or WinCC Client with
project, and consists of an Engineering Client as well as a
Runtime User interface.
• All engineering operations are performed using a graphic
Engineering Client. The Engineering Client is called up from
the WinCC Explorer.
• SIMATIC WinCC DowntimeMonitor provides ActiveX control
elements. These are used for displaying the determined
parameters and the progress of the various status over a
certain time period. These controls are integrated in WinCC
process images for presenting results.
• The recorded data is stored in an online database set and can
be moved to an offline database set.
• The basic package consists of the Engineering and Runtime
software and 5 licensed equipment units. Other licenses are
available for up to 25, up to 50, 100 and up to 200 equipment
units.
Siemens ST 80 · 2009
4/67
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/DowntimeMonitor
■ Function
4
■ Ordering data
• Creation of a time model by defining various time categories
as a basis for the KPI calculation for elements (equipment) to
be evaluated.
• Creation of equipment, as central components for the
evaluation by dividing the system into individual groups.
• Creation of a Reason Tree for detailed display of reasons for
downtimes.
• Allocation of the system status in the controller to the
time categories and Reason Trees defined in the
DowntimeMonitor.
• Storing the system status for calculating and presenting Key
Performance Indicators.
• The following pre-defined Key Performance Indicators are
available: Availability, change-over, cycle time, failure time
loss, duration, effective performance, maintenance, Mean
Time Between Assist (MTBA), Mean Time Between Failures
(MTBF), Mean Time To Assists (MTTA), Mean Time To Repair
(MTTR), failure time frequency, Overall Equipment Effectiveness (OEE), performance rate, production duration, quality
rate, speed loss, Total Efficient Equipment Performance
(TEEP), utilization.
• Integration of three new controls, Gantt View, KPI View and
Table View, in WinCC for the display of results for one or more
equipment units.
• The WinCC DowntimeMonitor Gant View presents the
equipment status development within a certain time period.
• The WinCC DowntimeMonitor KPI View shows the distribution
of failure times and the Key Performance Indicators in a trend,
bar, segmented bar charts or Pareto chart using historical
data.
• The WinCC DowntimeMonitor Table View shows raw data for
failure times and analyzes it in the selected time period. The
user can utilize these control elements to enter, change,
distribute or combine and comment on failure times manually.
• The controls can be displayed on intranet or Internet using the
option WinCC/Web Navigator.
4/68
Siemens ST 80 · 2009
Order No.
WinCC/DowntimeMonitor V1.0
SP1
for WinCC V6.2 SP2 and WinCC
V6.2 SP2 ASIA
• 5 equipment units
6AV6 372-1DB06-2BX0
• 25 equipment units
6AV6 372-1DB06-2DX0
• 50 equipment units
6AV6 372-1DB06-2FX0
• 100 equipment units
6AV6 372-1DB06-2HX0
• 200 equipment units
6AV6 372-1DB06-2KX0
WinCC/DowntimeMonitor
Powerpacks V1.0
• From 5 to 25 equipment units
6AV6 372-1DB06-2BD0
• From 25 to 50 equipment units
6AV6 372-1DB06-2DF0
• From 50 to 100 equipment units
6AV6 372-1DB06-2FH0
• From 100 to 200 equipment units
6AV6 372-1DB06-2HX0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/ProcessMonitor
■ Overview
■ Benefits
• Targeted analysis and interpretation of messages for working
out optimization strategies.
• Targeted analysis and interpretation of process value histories
during production to increase quality.
• Identification of major disturbances and weak points.
• Decision making based on customer-specific performance
indicators.
• Identification of the events that lead to cost-intensive failures.
• Detection of undesirable process activities.
• Entry point for an extended process analysis with upgrade
options in the MES software SIMATIC IT.
4
The entry point to SIMATIC Plant Intelligence can be through
options for the SIMATIC WinCC process visualization system.
The WinCC/ProcessMonitor is a component of WinCC Plant
Intelligence and is used for collecting, manipulating, evaluating,
and storing process values. Integrating the ProcessMonitor into
WinCC ensures complete transparency of all machine and plant
data as a basis for optimizing the plant’s productivity. The
process values are read directly from WinCC and are connected
with the respective analysis function.
• The SIMATIC WinCC ProcessMonitor can be installed on a
WinCC single station, WinCC Server or WinCC Client with
project, and consists of an Engineering Client as well as a
Runtime User interface.
• All engineering operations are performed using a graphic
Engineering Client. The Engineering Client is called up from
the WinCC Explorer.
• SIMATIC WinCC Process Monitor provides ActiveX control
elements that can be used for displaying historical data
originating from a user-definable time period and from various
data sources. These controls are integrated in WinCC images
for presenting the aggregated and stored data in the ProcessMonitor.
• The recorded data is stored in an online database set and can
be moved to an offline database set.
• The basic package contains 50 KPI. Further licenses are
available in levels of up to 250 and 1500 KPI.
Siemens ST 80 · 2009
4/69
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/ProcessMonitor
■ Function
4
■ Ordering data
• Storage and presentation of process data that is prepared
using pre-defined, user-defined, and context-dependent
statistic calculation operations.
• Utilization of limit value monitoring for measured values in
WinCC; above, below, within, or outside the limits.
• The following pre-defined statistic calculations are available:
Mean value, standard deviation in time period, variance, maximum in time period, minimum in time period, highest value in
time period, highest value with time data, minimum value with
time data, difference between minimum and maximum value,
total over a certain time period.
• Calculation of customer-specific individual Key Performance
Indicators with VBS (Visual Basic Scripting).
• Integration of the three other controls, that is Trend View, XY
Trend View, and Message Analyzer in WinCC for displaying
data from WinCC Tag Management, WinCC Tag Logging, and
WinCC Alarm Logging
• The WinCC ProcessMonitor Trend View provides up to 64
values from WinCC or ProcessMonitor. Display of the various
time intervals (Overlay Trend) or alternatively different process
values can be chosen over the same time interval (Standard
Trend).
• The WinCC ProcessMonitor XY Trend View: Display of dependencies of two different tags. Data sources are the ProcessMonitor and WinCC Taglogging.
• Filtering, analysis and display of WinCC messages in the
Message Analyzer. The results are displayed in a bar chart
based on algorithm-based calculations.
• The controls can be displayed on intranet or Internet using the
option WinCC/Web Navigator.
• Ad-hoc analyses for process data stored in the Process
Monitor or in the WinCC Tag Logging archive (from the
ProcessMonitor and WinCC Tag Logging) are possible.
Calculations can be defined for the runtime, the results of
which are output in the control.
4/70
Siemens ST 80 · 2009
Order No.
WinCC/ProcessMonitor V1.0
SP1
for WinCC V6.2 SP2 and WinCC
V6.2 SP2 ASIA
• 50 KPI
6AV6 372-1DA06-2BX0
• 250 KPI
6AV6 372-1DA06-2DX0
• 1500 KPI
6AV6 372-1DA06-2FX0
WinCC/ProcessMonitor
Powerpacks V1.0
• From 50 to 250 KPI
6AV6 372-1DA06-2BD0
• From 250 to 1500 KPI
6AV6 372-1DA06-2DF0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Connectivity Pack &
WinCC Connectivity Station
■ Overview
4
Cross-vendor communication in the automation sector has
always been of primary importance for WinCC. This is even more
true for the release of preprocessed production data for higherlevel information systems (e.g., MES = Management Execution
System, ERP = Enterprise Resource Planning or Office
packages = MS Excel, MS Access etc.). WinCC features
integrated OPC Data Access and OPC XML DA servers for
access to all online values in the system and makes open interfaces available for access to historical WinCC data.
• The Connectivity Pack includes OPC XML DA 1.01, OPC
HDA 1.20 (Historical Data Access), OPC A&E 1.10 (Alarm &
Events) and a WinCC OLE-DB interface which even allows
remote computers without WinCC to access WinCC archive
and alarm data
• The function of the OPC servers (XML DA, HDA and A&E) is
assured by the WinCC/Connectivity Pack. In order to access
data in the database via WinCC OLE-DB/OLE-DB, you will
also need a license for the WinCC/Connectivity Pack
• A Connectivity Pack license is required for every WinCC
system to be accessed
• When the Connectivity Station is used, an additional
ConnectivityPack license does not have to be installed on the
WinCC systems that are accessed. The Connectivity Station
functions autonomously and does not require a WinCC installation on the computer
• Access to WinCC archive and alarm data from a computer
without installed WinCC basic system license or WinCC option
via the interfaces of the Connectivity Pack or Connectivity
Station requires a WinCC/Client Access license on the client
side (see also "WinCC/Client Access License")
• Connectivity Station Option for WinCC V6.2 and higher
■ Benefits
• Access to variables, historical WinCC data, alarm data and
user archives from any computer
• Options for analyzing and evaluating process data with
specialist tools or user-defined applications (e.g., via VisualBasic)
■ Function
As an OPC HDA server, WinCC makes historical data from the
WinCC archive system available to other applications. An OPC
HDA client (e.g. a reporting tool) can define the time interval for
the required data by entering a start and end time. OPC HDA
servers also support the generation of a variety of aggregate
functions on the server itself (e.g. standard deviation, variance,
mean values, integral values, etc.), thereby helping to relieve the
load on the network, as only preprocessed data are transmitted.
OPC A&E servers are used to forward WinCC messages (along
with all associated process values) to any client at production or
enterprise control level. Filter mechanisms and subscriptions ensure that only selected modified data are transmitted.
Acknowledgement is of course also supported.
The WinCC OPC XML DA server makes cross-platform communication between Windows and non-Windows systems possible,
even via the Internet. This enables read and write WinCC online
values (external and internal WinCC variables) to be exchanged
with non-Siemens systems.
Siemens ST 80 · 2009
4/71
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Connectivity Pack &
WinCC Connectivity Station
■ Function (continued)
■ Ordering data
WinCC OLE-DB makes standardized and user-friendly access to
WinCC archive data possible (MS SQL Server 2005). In
exactly the same way as access via the OPC HDA and OPC A&E
interfaces, access via the WinCC OLE DB provider makes all
WinCC archive data available along with the associated process
values and message/user texts. The WinCC OLE-DB provider
also supports analysis functions such as minimum, maximum,
message hit list, etc.
The WinCC Connectivity Station was designed as a stand-alone
gateway to WinCC server data. It supports access to WinCC
server data over the OPC channels described as well as those
for process values (not alarms) over OLE DB . Access to WinCC
data is transparent, i.e. independent of which server of a redundant pair is active or whether data have already been transferred
to the central archive server.
4
Order No.
WinCC/Connectivity Pack &
WinCC/Connectivity Station
Basic packages
• WinCC/Connectivity Pack
V7.01)
6AV6 371-1DR07-0AX0
• WinCC/Connectivity Station
V7.01)
6AV6 371-1DR17-0AX0
• WinCC/Connectivity Pack
V6.2 SP2
6AV6 371-1DR06-2AX0
• WinCC/Connectivity Station
V6.2 SP2
6AV6 371-1DR16-2AX0
Upgrade1)
• WinCC/Connectivity Pack
V6.x -> V6.2 SP2
6AV6 371-1DR06-2AX3
Connectivity Station
1)
If no visualization is required at a station, any Windows computer
with access to WinCC via OPC and OLE-DB can be configured
via the Connectivity Station. This permits access to WinCC
stations with server packages from a central computer without
WinCC installation. The WinCC stations can be accessed via the
following interfaces:
• OPC interfaces of the Connectivity Station
• OLE DB interface of the Connectivity Pack
The two access variants are autonomous access options with
different ranges of functions.
OPC interfaces of the Connectivity Station
The Connectivity Station provides interfaces via which you can
access the following using an OPC-Client.
• OPC-DA-Server: tags, e.g. process values
• OPC-HDA-Server: archived process values
• OPC-A&E-Server: alarms
Licensing
You require the "WinCC Connectivity Station" license in order to
utilize the OPC interfaces of the Connectivity Station on a
computer without WinCC installed.
If you only use the OPC interfaces of a WinCC installation, you
only need the "Connectivity Pack" license.
The following table shows the combinations:
New: WinCC-independent installation
with Connectivity
Station
Standard installation: OPC with
WinCC
OPC DA
"WinCC Connectivity
Station" license
No license required
OPC HDA
"WinCC Connectivity
Station" license
"WinCC Connectivity
Pack" license
OPC A&E
"WinCC Connectivity
Station" license
"WinCC Connectivity
Pack" license
The Connectivity Station is planned over NCM PC Manager or
SIMATIC Manager. In Version 7, the Connectivity Station does
not run as service.
4/72
Siemens ST 80 · 2009
Upgrades from V6.x to V7.0 are included in the WinCC V7 upgrades
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/IndustrialDataBridge
■ Overview
4
• The WinCC/IndustrialDataBridge option uses standard
interfaces in order to connect the automation world with the
world of IT and ensure two-way information flow. Typical
examples of such interfaces are OPC in the field of automation
and SQL database interfaces in the world of IT.
• For example, SIMATIC WinCC with its OPC DA server interface is the data source and an external database is the data
destination.
• In addition to access to WinCC variables, access to
messages, process values and user archive data (in the
WinCC database) is also supported.
• As a stand-alone application with its standard interfaces,
such as OPC DA and OLE-DB, WinCC/IndustrialDataBridge
can be also be used in conjunction with SIMATIC NET and
SIMATIC WinAC, for example.
• Option from WinCC V6
• The IndustrialDataBridge can be integrated into WinCC and
can also be used in stand-alone mode (not in conjunction
with WinCC)
■ Benefits
• Connecting the automation level with the IT world
• Integration of systems from different manufacturers via a
host of standard interfaces (including OPC, OLE-DB, Office
formats)
• Simple configuration with standard software without
programming and thus at low cost
• High-performance data transfer between several systems
simultaneously
■ Design
The software comprises a configuration environment and a
runtime environment. The different data interfaces are integrated
via software modules. In each case, one module is required as
the data source and one module as the data destination. The
different modules can be combined in any way.
The connections between data source and data destination are
created in the configuration environment. In the runtime environment, the IndustrialDataBridge establishes the connection
autonomously and transfers the data of the linked variables.
Siemens ST 80 · 2009
4/73
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/IndustrialDataBridge
■ Function
Interfaces:
The table below shows the possible data sources and
destinations:
4
Provider (data sources)
Consumer (data destinations)
• MS Access
• MS SQL server
• MySQL ODBC (new)
• Oracle 8i, 9i and 10i)
• OPC Data Access V2
• Send/Receive
• WinAC Send/Receive
• WinCC OLE DB
• WinCC UserArchive
• CSV, TXT
• MS Access
• MS SQL server
• MySQL ODBC (new)
• Oracle 8i, 9i and 10i
• MS Excel
• OPC Data Access Server
(internal)
• OPC Data Access V2
• Send/Receive
• WinAC Send/Receive
• WinCC UserArchive
■ Ordering data
• IndustrialDataBridge establishes a link between the source
and destination interfaces and transfers data on the basis of
a change in value, once a configurable period of time has
elapsed or when a specific event occurs.
• IndustrialDataBridge exchanges data between automation
systems from different vendors, e.g., via OPC. The connection
of OPC servers via IndustrialDataBridge enables communication between a variety of devices, data sources and data
destinations. The OPC international interface standard is the
key to open systems both now and in the future. Thanks to
IndustrialDataBridge, OPC data exchange can already be
supported.
• WinCC supports access to variables, tag logging, alarm
logging and user archive data.
• Storage of process data in Office formats such as Excel or
Access. Databases can also be integrated for the archiving
of larger aggregates.
• One of the features of IndustrialDataBridge is a Send/Receive
interface supporting data transfer to SIMATIC S5/S7 stations
or other Send/Receive-compatible devices.
• IndustrialDataBridge enables SCADA and control systems
from different vendors to be linked via the OPC interface.
Communication via RFC1006 or Send/Receive is also
supported.
• SQL databases are available as data destinations for production data acquisition. Data can be transferred from the data
source on an event-driven basis with the OPC module or sent
directly from the PLC with the Send/Receive module.
• Cyclic data archiving can be implemented via the OPC Data
Access, WinAC ODK or Send/Receive data sources and the
SQL database data destinations. On the database side,
various transmission mechanisms are supported.
4/74
Siemens ST 80 · 2009
Order No.
WinCC/IndustrialDataBridge
V7.0, option for WinCC V7.0
for data exchange with databases
and OPC servers, language
versions: German/English
• with 128 tags
6AV6 371-1DX07-0AX0
• with 512 tags
6AV6 371-1DX07-0BX0
• with 2048 tags
6AV6 371-1DX07-0CX0
• with 10000 tags
6AV6 371-1DX07-0DX0
WinCC/IndustrialDataBridge
PowerPack V7.0
• from 128 to 512 tags
6AV6 371-1DX07-0AB0
• from 512 to 2048 tags
6AV6 371-1DX07-0BC0
• from 2048 to 10000 tags
6AV6 371-1DX07-0CD0
WinCC/IndustrialDataBridge
upgrade
from V6.1 to V7.0
6AV6 371-1DX07-0XX4
WinCC/IndustrialDataBridge
V6.1, option for WinCC V6. 2
for data exchange with databases
and OPC servers, language
versions: German/English
• with 128 tags
6AV6 371-1DX06-1AX0
• with 512 tags
6AV6 371-1DX06-1BX0
• with 2048 tags
6AV6 371-1DX06-1CX0
• with 10000 tags
6AV6 371-1DX06-1DX0
WinCC/IndustrialDataBridge
PowerPack V6.1
• from 128 to 512 tags
6AV6 371-1DX06-1AB0
• from 128 to 2048 tags
6AV6 371-1DX06-1AC0
• from 128 to 10000 tags
6AV6 371-1DX06-1AD0
• from 512 to 2048 tags
6AV6 371-1DX06-1BC0
• from 512 to 10000 tags
6AV6 371-1DX06-1BD0
• from 2048 to 10000 tags
6AV6 371-1DX06-1CD0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Client Access License (CAL)
■ Overview
• For a system on which WinCC (WinCC basic system or WinCC
Option) has not been installed, WinCC data can be accessed
through the interfaces of the options WinCC/Connectivity
Pack, WinCC/Connectivity Station or WinCC/IndustrialData
Bridge.
• For any number of systems (multi-processor systems) without
WinCC (WinCC basic system or WinCC Option), WinCC data
can be accessed through the interfaces of the options
WinCC/Connectivity Pack, WinCC/Connectivity Station or
WinCC/IndustrialDataBridge with one WinCC/Client Access
License (CAL) per processor. One CAL must be purchased for
each processor of the WinCC system.
• Option only for WinCC V6
■ Ordering data
WinCC/Client Access License
Order No.
6AV6 371-1ES06-0AX0
For client access to historical
WinCC data
WinCC/Client Access License
per processor
6AV6 371-1ES06-0CX0
For access to historical WinCC
data; any number of clients per
processor
■ Function
4
With the integrated MSSQL Server, WinCC V6 offers an excellent
basis for integrated data management and diverse methods of
integration into modern IT structures.
Access to the data available in WinCC requires the relevant
license on all accessing computers - the WinCC Client Access
License. The WinCC/CAL is installed on these accessing
systems along with a WinCC basic package or a WinCC option.
On all other systems, a WinCC/CAL must be obtained separately. It allows users to further process WinCC data with their
own tools and make them available to other users and applications. Use of the "Per Processor License" allows access by any
number of computers to this WinCC system.
Siemens ST 80 · 2009
4/75
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/User Archives
■ Overview
■ Function
• Input of parameter sets (e.g. operating parameters of a
machine) in WinCC, storage of the sets in the user archive,
and forwarding to the automation level
• Continuous acquisition of production parameters by the automation system and forwarding of the parameters to WinCC at
the end of the shift
• Acquisition of batch data
• Specification of production parameters
• Management of warehousing data
WinCC user archives are created and assigned data in a userfriendly way using a dedicated editor. Special ActiveX controls
are used for displaying data from the user archives at runtime.
4
Data sets and fields from user archives are linked to the process
via direct tag linking.
• Option for SIMATIC WinCC for managing data sets in user
archives that contain related data.
• WinCC and its automation partners (e.g. a SIMATIC S7
controller) write these data sets and exchange them if
required.
• A license is only required for the server (or single-user
system).
The WinCC/User Archives option can also be used in the context
of the WinCC/Web Navigator (see also WinCC/Web Navigator
option).
■ Benefits
• Storing and managing of any user data in data sets
• Flexible display using ActiveX controls
• Simple linking of data set fields to the process via direct tag
linking
• Import/export functions for further processing with other tools
(e.g. MS Excel)
4/76
Siemens ST 80 · 2009
Import and export functions support read-in/out of data via
external applications (e.g. MS Excel). Freely selectable filter
criteria allow clear representation of data sets.
WinCC provides functions for free organization of the data
storage in the user archives that affect archives, data sets and
fields. Archives can thus be generated, opened, closed, or
reset, and data sets or field contents can be read, written or
overwritten.
Sequence archives can accommodate batch data, shift production data, or also product quality data, and meet legal obligations for verification thanks to gap-free recording.
■ Ordering data
Order No.
WinCC/User Archives
• for WinCC V7.0
6AV6 371-1CB07-0AX0
• for WinCC V6.2
6AV6 371-1CB06-2AX0
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC BATCH (for WinCC)
■ Overview
■ Benefits
• WinCC in connection with the SIMATIC BATCH product range
offers a solution for the implementation of batch processes in
accordance with ISA S88.
• SIMATIC BATCH (for WinCC) is of particular interest where
different PLCs such as S7-400/300, S5 or non-Siemens PLCs
are to be used in a BATCH system.
• SIMATIC BATCH (for WinCC) is offered as a bundle that includes the SIMATIC BATCH components as well as the WinCC
components.
• SIMATIC BATCH (for WinCC) contains the software for
SIMATIC BATCH including options, as well as for SIMATIC
WinCC including options. These products are released for any
combinations.
- SIMATIC BATCH (for WinCC) includes the licenses SIMATIC
BATCH Server (10 units1), SIMATIC BATCH BATCH CC, and
SIMATIC BATCH Recipe.
- All other SIMATIC BATCH and SIMATIC WinCC products
require the purchase of the relevant license or licenses.
1)
Units are the number of subsystems that can be operated with this license.
Current versions:
• SIMATIC BATCH (for WinCC) V7.0 SP1
- WinCC V6.2 SP2
- SIMATIC BATCH V7.0 SP1
• SIMATIC BATCH (for WinCC) supports the user in the implementation of batch processes in accordance with ISA S88
• Modular architecture with flexible scalability and optimal adaptation to plant size and individual requirements, especially
with regard to the use of PLCs such as SIMATIC S7-400/300,
SIMATIC S5 and non-Siemens devices
• High availability via redundant system configurations provides
protection against loss of batch data
• Cross-subsystem recipes with significant simplification of
recipe management
• Hierarchical recipes in accordance with ISA S88.01 for the
creation of recipes oriented toward process engineering
• Storage, archiving and extensive logging of batch data in XML
format
• Formula support
• Validation in accordance with 21 CFR Part 11 is significantly
simplified by functions such as Audit Trail (change log), versioning of recipes, recipe operations and formulas, electronic
signature and access protection.
■ Application
SIMATIC BATCH (for WinCC) has been designed for:
• Batch processes in the WinCC environment in accordance
with ISA S88
• Users of S7-300, S7-400, S5 or non-Siemens controllers
• Users of STEP 5/STEP 7
Configuration
SIMATIC BATCH (for WinCC)
BASIC 10 Units
PROCESS BUS
S5-135U
S7-300/400
G_ST80_XX_00263
3rd-party PLCs
SIMATIC BATCH (for WinCC)
Siemens ST 80 · 2009
4/77
4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC BATCH (for WinCC)
■ Design
■ Function
SIMATIC BATCH (for WinCC) ships with the following 3 software
components and licenses:
• SIMATIC BATCH Server for 10 units
• SIMATIC BATCH Recipe system (Floating License)
• SIMATIC BATCH CC (Floating License)
4
The following SIMATIC BATCH options can be used to expand
or configure a plant or the relevant licenses can be purchased:
• SIMATIC BATCH Recipe system (Floating License)
• SIMATIC BATCH Planning (Floating License)
• SIMATIC BATCH CC (Floating License)
• SIMATIC BATCH Library
• SIMATIC BATCH Hierarchical Recipe
• SIMATIC BATCH Formula
• SIMATIC BATCH Power Packs (20, 40, 100, unlimited)
The following basic products and SIMATIC WinCC options can
be used to expand or configure a plant or the relevant licenses
can be purchased.
• SIMATIC WinCC RT/RC (incl. Power Packs)
• SIMATIC WinCC/Server
• SIMATIC WinCC/Redundancy
• SIMATIC WinCC/Archives (incl. Power Packs)
• SIMATIC Logon
All previously listed software components including options of
SIMATIC BATCH and SIMATIC WinCC are supplied with the
product SIMATIC BATCH (for WinCC). In addition, supplementary components for configuring the interfaces between WinCC
and SIMATIC BATCH are included in the basic package. The use
and compatibility of WinCC and SIMATIC BATCH is only guaranteed for the software versions that come with SIMATIC BATCH
(for WinCC).
4/78
Siemens ST 80 · 2009
The functions of SIMATIC BATCH (for WinCC) are based on the
SIMATIC BATCH range of products. SIMATIC BATCH (for
WinCC) includes the following licenses or functions:
• SIMATIC BATCH Server for 10 units
• SIMATIC BATCH CC (BATCH Control Center)
• SIMATIC BATCH Recipe System (recipe editor)
It can be used to run a SIMATIC BATCH project with 10 subsystems on a single-user station or a client/server combination
(Batch Client and Batch Server).
The capacity of the Server Basic Packages with 10 units can be
expanded to 20, 40, 100 or unlimited units using SIMATIC
BATCH PowerPacks.
SIMATIC BATCH CC offers powerful functions for the following
tasks:
• Reading in and updating the plant data of the basic
automation
• Defining user privileges for all functions, for clients or
subsystems
• Definition of material names and codes
• Managing master recipes and starting the recipe editor
• Management of libraries with recipe elements (library
operations)
• Editing of formula categories and management of associated
formulas (parameter sets)
• Creation of batches with master recipes
• Starting of batch processing and controlling of batches
• Monitoring and diagnostics of batch processing
• Recording and archiving of recipes and batch data
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC BATCH (for WinCC)
■ Function (continued)
SIMATIC BATCH Hierarchical Recipes enables the creation
hierarchical recipes in accordance with ISA-88:
4
The hierarchical recipe structure is mapped on the plant module
as follows:
• Recipe procedure for controlling the process or the production in a plant
• Partial recipe procedure for controlling a process step in a
plant unit
• Recipe operation/function to implement the process engineering task/function in a technical facility
The flexibility achieved by recipes which are independent of
plant units can be increased even further if the procedure and
parameter sets (formulas) are separated from one another. Various master recipes can be created by linking several formulas
using a recipe procedure. This enables central modification of
procedures. The formula structure is determined by the formula
category defined by the user.
SIMATIC BATCH Separation, Procedures and Formulas offers
powerful functions for the following tasks:
In respect of compatibility, please note that only the SIMATIC
WinCC and SIMATIC BATCH versions included in the product
package are compatible with each other. Only predecessor
products of the product bundle SIMATIC BATCH (for WinCC) are
upward compatible, not single components of the product range
SIMATIC WinCC and SIMATIC BATCH.
Compatibility
■ Integration
Formula 1
Formula 2
Formula 3
Temperature
1000 kg
90 °C
500 kg
80 °C
900 kg
95 °C
Time
10 min
15 min
12 min
Salt
Pepper
Sugar
Yes
No
100 g
Yes
No
150 g
No
Yes
50 g
Quantity
Master Recipe #1
Master Recipe #2
A detailed description of how to integrate SIMATIC Batch in
WinCC appears in the interface description "SIMATIC BATCH
Configuration Guide".
■ Ordering data
SIMATIC BATCH (for WinCC)
Master Recipe #3
Order No.
6ES7 657-1SA07-0YA0
Software bundle for the creation
of recipes and control of batch
processes in accordance with
ISA S88 based on SIMATIC
BATCH.
• SIMATIC BATCH Server 10 units
• SIMATIC BATCH Recipe system
(Floating License)
• SIMATIC BATCH CC
(Floating License)
Siemens ST 80 · 2009
4/79
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/ChangeControl & WinCC/Audit
■ Overview
4
■ Benefits
• WinCC/ChangeControl is used to trace engineering
changes in a tamper-proof long-term audit trail database,
called the audit trail for short. All changes are automatically
entered in the engineering system in the audit trail. This
enables all the changes to be traced that have been made, to
deduce the causes and minimize downtimes on the system.
To begin tracing at a defined project status, a project version
definition is provided that contains all data and files of a
WinCC project version. The project version definition naturally
provides the ability to reactivate earlier project versions.
Document management is also provided, which manages and
archives intermediate status for system graphics, reports or
user files and stores change information of the user. An audit
viewer with helpful filter functions can be used for quickly and
simply evaluating the audit trail, exporting it to an Excel sheet
or printing it out.
• WinCC/Audit Includes the full functionality of WinCC/
ChangeControl and is also used for tracing all operations. All
operations are automatically recorded in the audit trail at RT.
• Licensing: To configure which change information from the
project should be recorded in the audit trail, the WinCC/
ChangeControl RC or WinCC/Audit RC package is required.
"RC" stands for Runtime and Configuration. It is required on
the station that is to be configured and also includes an RT
license. For recording an audit trail, one WinCC/Audit RT
license is required per WinCC station (Client/Server).
• The WinCC/Audit or WinCC/ChangeControl and SIMATIC
Logon options support users in respect of plant validation and
meet the requirements of FDA CFR 21 Part 11. A declaration
of conformity (White Paper) offers proof of this.
4/80
Siemens ST 80 · 2009
• Quick and easy traceability configuration
• Gap-free and automated recording of engineering changes
and operator actions in an audit trail
• Reduction in plant downtimes thanks to fast analysis of the
gap-free recorded audit trail information
• Logging of defined WinCC project status with all database
information and files of the application
• Gap-free documentation of the project version definition
procedures with version number, user and comments
• Complete tracing support by WinCC single and multi-station
systems, single and multi-project solutions, Client/Server
architecture
• Extensive reduction in engineering outlay in order to meet the
requirements of FDA 21 CFR Part11 & EU 178/2002
• Compliance with the requirements of the Food and Drug
Administration (FDA) for the food, beverages and tobacco
industries
■ Design
WinCC/ChangeControl and WinCC/Audit consist of five
components:
• The audit editor for configuration the audit trail content
• The project version definition for logging WinCC projects
• Document management for automatic archiving and
versioning of WinCC plant mimics, scripts, reports, and
project-specific documents, and the recording of the
associated change information
• The audit viewer for visualizing, exporting and printing WinCC
and WinCC flexible audit trails. The viewer is available as an
executable program under Windows, as well as OCX with
WinCC Runtime.
• The audit trail, which tracks all changes in respect of both
engineering and plant operation in a separate SQL database.
The audit trail can be set up as a central audit trail for a
number of projects or even just for a single project.
WinCC/ChangeControl and WinCC/Audit support both singleuser and multi-user systems, client/server architectures and
even the WinCC redundancy system. No redundant audit trail
is created however.
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/ChangeControl & WinCC/Audit
■ Function
■ Ordering data
WinCC/ChangeControl
WinCC/ChangeControl RC
WinCC/ChangeControl is a functional subset of WinCC/Audit.
WinCC/ChangeControl is for tracing engineering changes in the
engineering phase or in online operation. All change data is
recorded in an audit trail.
For the configuration of the audit
trail incl. RT
There are two types of engineering changes:
• those that change the WinCC database or are executed
through the WinCC Explorer, such as e.g. changes to tag
management or creating a user group,
and those
• limited to changing files, the so-called document administration.
• V7.0, for WinCC V7.01)
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2
• V7.0, for WinCC V7.01)
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2
The project version definition as a component of
WinCC/ChangeControl archives WinCC projects and creates reproducible project status or defined start-time points for starting
tracing.
An audit trail is also provided with information on who has created which project version or which version has been reproduced or deleted.
V6.x to V7.01)
WinCC/Audit
WinCC/Audit has all of the functionality off WinCC/ChangeControl and is also used for tracing user operations in RT operation.
Tracing can be used for determining who, when and what
conditions the machine has undergone. In addition to recording
operator activities, the audit trail also records the starting and
modifying of recipes or user logs. At specific objects or events,
such as function buttons or sliders, the user can also record
activities of an individual nature such as e.g., pressing a function
button, moving sliders and other actions with a so-called audit
entry function in the audit trail.
6AV6 371-1DV26-2AX0
For the configuration of the audit
trail incl. RT
WinCC/Audit RT
The audit trail data is visualized from WinCC, as well as from
WinCC flexible via the audit viewer, an executable program
under Windows. The data can also be evaluated with the audit
viewer OCX in Runtime by WinCC however. Users select the
desired view of the audit trail information via filters or selection
criteria and can export the data to an Excel file or print it on a
printer. Audit trail information is tamper-proof and can thus not
be modified or deleted. An export function can be used to swap
out the audit trail to an XML file or to archive it.
6AV6 371-1DV27-0AX0
B
WinCC/Audit RC
The document management manages system images, scripts
and log layouts and customer-specific documents and stores
respective intermediate versions as backups. All of these
documents or files are subject to a change process, i.e. documents can be booked out for processing, booked in for finalization and intermediate versions can be retrieved from backup
storage with a rollback function.
Configuring the audit trail, the project version definition and the
document management is simple, quick and comfortable.
Order No.
6AV6 371-1DV17-0AX0
B
6AV6 371-1DV16-2AX0
4
Creation of the audit trail in RT
• V7.0, for WinCC V7.01)
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2
6AV6 371-1DV07-0AX0
B
6AV6 371-1DV06-2AX0
Upgrades
• for WinCC/ChangeControl RC,
WinCC/Audit RC and WinCC
Audit RT
6AV6 371-1DV07-0AX4
V6.x to V6.2
• for WinCC/Audit RC and
WinCC Audit RT
B
6AV6 371-1DV06-2AX3
B) Subject to export regulations: AL: N und ECCN: EAR99S
1)
Expected start of delivery for Version V7.0: 09/2008
■ More information
Information about FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC to FDA21 CFR
Part 11.
Additional information is available in the Internet under:
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm
A WinCC/ChangeControl RC license or a WinCC/Audit RC
license is required for configuring the audit trail. One RT license
is required for each station (client/server) to be monitored. One
RC license always includes one RT license.
Siemens ST 80 · 2009
4/81
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
SIMATIC Logon
■ Overview
■ Function
SIMATIC Logon
Users receive a unique user ID, user name and password. This
information is stored encrypted at a central point (for SIMATIC
Logon in the Windows user management). Functions such as
changing the password, automatic logoff after a predefined time
and lockout after several incorrect entries of a password ensure
maximum security of operation.
In the case of the SIMATIC Logon, user administration is
integrated into the security system and user administration of
MS Windows.
4
• SIMATIC Logon (SL) for WinCC is a software option package
supporting the central administration of all WinCC users on a
plant-wide basis. The central user management with SL uses
the Windows mechanisms and is to be installed on all participating WinCC stations. The user management actions such as
logging in and out are automatically supplied in the audit trail
of WinCC/Audit and WinCC/ChangeControl by SL.
• The WinCC/Audit or WinCC/ChangeControl and SIMATIC
Logon options support users in respect of plant validation and
meet the requirements of FDA CFR 21 Part 11. A declaration
of conformity (White Paper) offers proof of this.
To meet in particular the Food and Drug Administration (FDA)
requirements for the pharmaceuticals and food processing
industry, all user and administrator actions, such as log in, log
out, password changes, incorrect password inputs, and
creating and deleting users, are recorded with timestamp in a
secure database or are available in the audit trail of
WinCC/Change Control or WinCC/Audit.
In addition, SIMATIC Logon allows setting up new users online,
plant-wide and across applications, or blocking existing users.
SIMATIC Logon also supports electronic signature.
■ Ordering data
SIMATIC Logon V1.4-SP1
■ Benefits
• Central, system-wide user management
• Conforms with the requirements of the Food and Drug
Administration (FDA) for the pharmaceuticals and food
processing industry
■ Design
Order No.
6ES7 658-7BX41-2YA0
Central user management for
WinCC V6.2 and WinCC V7.0
Runtime license for an operator
station1)
1)
SIMATIC Logon V1.4 included in scope of supply of WinCC V7.0
■ More information
The SIMATIC Logon Service can be used for the central user
management of a number of WinCC stations. Operation in a
Windows Workgroup or even in a domain is possible.
Information on FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC for
FDA21 CFR Part 11.
Additional information is available in the Internet under:
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm
4/82
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/IndustrialX
■ Overview
■ Application
IndustrialX controls create standardized presentations and allow
flexible customization to the requirements of a wide range of
applications, e.g. applications in the chemical, glass or paper
manufacturing industries.
■ Function
• Configuring intelligent, industry-specific objects (graphic
illustration and logical processing) with know-how protection
• Automatic object supply with WinCC data structures
(templates)
• Creation of Web Navigator-compatible, customer-specific
ActiveX components with active process data supply
• Integration into WinCC via structure names
■ Ordering data
4
Order No.
WinCC/IndustrialX
• V7.0; for WinCC V7.0 and V6.x
6AV6 371-1EL17-0AX0
• WinCC/IndustrialX makes it easier to develop a solution for a
visualization task by allowing customized objects to be
standardized
• A license must be installed on each development computer
(current version of Visual Basic must be installed on the
development computer)
■ Benefits
• Easy creation using configuration wizards
• Quick entry due to the use of standards: ActiveX technology,
creating with the aid of Visual Basic
• Central creating and changing of object displays of the same
type (typing) saves time and money
• Configuring of intelligent, sector-specific objects (graphic
illustration and logical processing) with know-how protection
• Can be used in versatile ways: in WinCC screens and other
Windows applications (e.g. Internet Explorer, Excel)
Innovations of V7.0
Support of Visual Studio 2005 (.NET)
Siemens ST 80 · 2009
4/83
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/ODK
■ Overview
■ Function
WinCC/ODK (Open Development Kit)
• WinCC option for utilization of the exposed programming
interfaces that can be used to access data and functions of
the WinCC configuration and WinCC runtime system
• The interfaces are designed as "C-Application Programming
Interface" (C-API)
• Scope of delivery:
- CD-ROM with examples
- Voucher for a one-day intensive workshop
■ Benefits
4
• Individual system expansions via an open standard
programming language
• Access to data and functions of the WinCC configuration
and runtime system
• Development of your own applications and add-ons for the
WinCC basic system
Innovations of V7.0
Support for Visual Studio 2005 (.NET)
4/84
Siemens ST 80 · 2009
The API functions are configuration and runtime functions, and
include:
• MSRTCreateMsg: Creates a message
• DMGetValue: Gets the value of a variable
• PDLRTSetProp: Sets the object properties in a display
They can be used in the following places:
• within WinCC, for example in global scripts or as part of C
actions in the Graphics Designer,
• in Windows applications in the programming language C
(the current version of Microsoft Visual C++ is necessary as a
development environment for WinCC).
■ Ordering data
Order No.
WinCC/ODK
• V7.0; for WinCC V7.0 and V6.x
6AV6 371-1CC07-0AX0
WinCC/ODK upgrade
• to V7.0
6AV6 371-1CC07-0AX4
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC/Comprehensive Support
■ Overview
• With Comprehensive Support, WinCC offers an SUS (Software
Update Service) as a comprehensive support package.
• The overall package includes the latest updates/upgrades for
WinCC incl. options.
• The WinCC user receives a contract at the beginning and
update products are sent automatically for a period of 12
months. The contract is automatically extended by a further
year unless canceled up to 12 weeks prior to expiration.
• WinCC Comprehensive Support has to be purchased for each
WinCC System (single-user system, server, client). In order to
ensure that users of multiple systems can gain access to
WinCC Comprehensive Support at a competitive price, in
addition to the package with one license, a discounted
package with 3 and 10 licenses is available.
■ Ordering data
Order No.
WinCC/Comprehensive
Support1)2)
Automatic delivery of current
updates/upgrades for WinCC
basic software and options
Valid for
• 1 license
6AV6 381-1AA00-0AX5
• 3 licenses
6AV6 381-1AA00-0BX5
• 10 licenses
6AV6 381-1AA00-0CX5
1)
Comprehensive support runs for one year. The contract is automatically
extended by a further year unless canceled 3 months prior to expiry.
2)
Requires the current software version
■ Benefits
4
• Automatic distribution of current upgrades and service packs
for WinCC ensures that the latest WinCC version is always
available
Siemens ST 80 · 2009
4/85
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC Premium Add-on and
partner management
■ Overview
C
WinCtion
Op
C
WinCd-on
Ad
C
WinCis-SW
Bas C, RT
R
C
WinCtion
Op
C
WinCd-on
Ad
C
WinCtion
Op
4
Premium Add-ons for Connectivity:
• PM OPEN IMPORT system software
for importing WinCC flexible archives into the WinCC system.
• PM OPEN EXPORT system software
for exporting WinCC data to local storage media or storage
media released in the network.
• PM OPEN TCP/IP system software
permits bidirectional exchange of WinCC data (tags, messages) with one or more computers that communicate using
the TCP/IP protocol.
• Historian CONNECT ALARM system software
permits importing of messages and alarms from WinCC and
WinCC flexible into the SIMATIC IT Historian.
• WinCC OPC Alarm & Event Client
is used to transfer alarms and messages from any OPC A&E
server complying with the specification to the WinCC signaling
system.
Siemens Automation
SYSTEM PARTNER
WinCC Professional
G_ST80_XX_00176
C
WinCd-on
Ad
WinCC Premium Add-ons – Solutions for all sectors and
technologies
The basic system is designed to be independent of any specific
technology or industrial sector, to be modular and flexibly expandable and to permit not only simple single-user applications
in machine construction, but also complex multi-user solutions
or even distributed systems with several servers and clients in
plant engineering. WinCC Premium Add-ons are supplementary
products that have been created by competent partners working
in the specifc sectors and technologies and represent interesting expansions for WinCC.
WinCC Premium Add-ons are not IA (Siemens Industry
Automation) products, but the products of partners who are
committed to complying with certain quality features and boundary conditions. The Premium Add-ons are checked, for example,
in the Siemens Test Center for their compatibility with the basic
WinCC system and supported in the first instance by the central
Hotline. As they are important application- and sector-specific
add-on products for SIMATIC WinCC, they are marketed jointly
by Siemens and the respective add-on suppliers. The WinCC
Premium Add-on products can be found on the Internet (see
Further Information) and in the "Online WinCC Premium Add-on
Catalog".
4/86
Siemens ST 80 · 2009
Premium Add-on for process management:
• PM CONTROL system software
is a recipe system for user-friendly generation and modification of recipes.
• PM QUALITY system software
is an archive system for the administration of job and batchrelated production and process data.
Premium Add-on for sector products:
• B.Data energy management system
is a modular and cross-sector energy management and plant
information system for industrial power companies.
• SIMATIC WinCC powerrate
provides the basis for continuous reduction of the power
consumption, and thus also of the energy costs.
• [email protected] HVAC function library
offers control and component blocks for heating, ventilation
and air-conditioning systems.
• ACRON for WinCC/PCS 7
is used for long-term archiving and logging of process data for
small to medium-sized plants, specifically in the water supply
and treatment industry.
Premium Add-on for configuration tools:
• DCC TranslationEditor for translating multilingual projects with
in-built security, convenience and globalization features.
Premium Add-on for diagnostics and maintenance:
• Management System Alarm Control Center
for transmitting fault messages via various communication
paths, such as GSM, LAN, e-mail.
• PM MAINT system software
is a tool for the maintenance of production plants.
• PM ANALYZE system software
for analysis of fault and operating messages, as well as
process values.
• ShutDown WinCC system software
terminates the WinCC Runtime software in the event of a
power failure, minimizes plant downtimes, and increases data
integrity.
• System diagnostics instrumentation and control
for reading out the status of the instrumentation and control.
© Siemens AG 2008
HMI Software
SCADA system SIMATIC WinCC
WinCC Premium Add-on and
partner management
■ Oerview (continued)
■ More information
Competent partners
WinCC Competence Center
With SIMATIC HMI, you not only get excellent products to suit
your requirements, but we will also support you with selecting a
partner for your automation solution. In our global network of
Siemens Automation Solution Providers you will always find competent partners in your neighborhood. In addition, we implement
and support the Siemens-internal WinCC Competence Centers
and the WinCC Professionals external system integrators on the
basis of WinCC customer- and industry-specific and economic
solutions.
Additional information is available in the Internet under:
http://www.siemens.com/winCC/competencecenter
Siemens Solution Partner Automation
Additional information is available in the Internet under:
http://www.siemens.com/automation/solutionpartner
WinCC Competence Centers
Mannheim
Emphasis on process management
• Sector-independent solutions and products in the fields:
Production, environmental protection, maintenance and diagnostics
• Connectivity tools, system integration, connection to SAP R/3
• Support of FDA validation and WinCC ODK
• Support for advanced users with application of ODK and VBA
WinCC Premium Add-on
Additional information is available in the Internet under:
4
http://www.siemens.com/winCC/addons
Stuttgart
Emphasis on production technology
• Solutions for maintenance management
• Web-based solutions with WinCC
Erlangen
Emphasis on process automation
• MES connectivity
• Plant information, maintenance, batch and quality management
• Web-based solutions with WinCC
• Customized database interfacing
Nuremberg
Solutions in the Oil & Gas, Metal & Mining, Pulp & Paper sectors
• Network and security
• Microsoft Certified
• Migration from COROS to WinCC
• Customized expansions also for WinCC flexible
• Web solutions
• Customized workshops, e.g. training for VBS, VBA, CBarcelona
Emphasis on production automation and logistics
• Solutions for integration of WinCC into MES and ERP
• Development of WinCC add-ons
Nice
Solutions in the food and beverages sector, pharmaceuticals
and process engineering
• Batch processes
• Migration of SIMATIC TI, Teleperm M and PCS systems to
WinCC
• Customized expansions
• FDA support
• Migration of TI systems
Siemens ST 80 · 2009
4/87
© Siemens AG 2008
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Overview
■ Benefits
• Process diagnostics software for quick, selective fault diagnostics in plants and machines for SIMATIC S7 and SIMATIC
HMI
• A standardized diagnostics concept for various SIMATIC
components:
Optimum interaction between STEP 7 engineering tools and
SIMATIC HMI
• Standard user interface
• Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• ProAgent:
- Provides optimum support for plant and machine personnel
in respect of troubleshooting and fault rectification
- Increases plant availability
- Reduces downtimes
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time
• No special operator know-how is required thanks to clearly
comprehensible indication of the cause of error
■ Application
4
*B67B;;B
67(3
Process fault diagnostics with ProAgent for ProTool and
WinCC flexible/ProAgent as well as the STEP 7 engineering tools
Increased productivity is being achieved more and more by
cutting costs. In this context, the focus is increasingly on maintenance. The emphasis here is on rectifying faults as quickly and
efficiently as possible. Ideally, the operating personnel should
also perform part of the maintenance tasks. The operating personnel are on-site, they are familiar with the procedures and can
intervene quickly. This saves time and reduces costs. It is
precisely here that ProAgent can assist operating personnel in
identifying faults quickly, in particular in the automotive and machine tool industries.
In the event of a process fault, process fault diagnosis with
SIMATIC ProAgent will provide information about the location
and cause of that fault and support personnel with troubleshooting.
The ProAgent solution has been optimized specifically for use
with SIMATIC S7-300/S7-400 and SIMATIC WinAC. It can be
used in combination with the S7-PDIAG, S7-GRAPH and
S7-HiGraph1) STEP 7 engineering tools. The ProAgent option
package features standard displays that are updated with
process-specific data during runtime.
1)
3B67B;;B
67(3
Process fault diagnostics with WinCC/ProAgent and the STEP 7
engineering tools
4/88
Siemens ST 80 · 2009
Process diagnostics with S7-HiGraph in combination with
TP/OP/MP270/277, MP370/377 as well as with C7636 and PC RT systems.
© Siemens AG 2008
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Function
• Context-sensitive diagnostics initiation due to process error
message
• Output of operands with symbols and comment
• Switching is possible between LAD, STL and signal list
• Supporting fault rectification with direct process access when
using the motion display
• Output of the faulty operands directly in the message including address, symbol and comment1)
• Consistency test in RT:
Inconsistent diagnostic units are marked with icons. This permits quick locating of faults regarding configured data in the
commissioning phase.
• Direct, unit-related entry point in the diagnostic display from
user displays by using ProAgent functions
• Unit or message-related entry to STEP 7 (LAD/STL/FD editor,
S7-GRAPH, HW CONFIG (upon system error messages)),
supported fully automatically2)
• Unit or message-related entry to STEP 7), supported fully
automatically3)
• Graphic display of step sequences (overview display)4)
1)
In combination with TP/OP/MP 270/277, MP370/377, C7 636, WinCC/
ProAgent as of V6.0, and WinCC flexible/ProAgent
2)
WinCC/ProAgent as of V5.5 and as of WinCC flexible 2007/ProAgent on
PC RT
3)
Only WinCC/ProAgent as of V5.5
4)
As of WinCC flexible 2007/ProAgent, WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1 (OCX is delivered as of S7-GRAPH 5.1)
Message display
All of the existing process messages are shown in the message
display. Context-sensitive branching to other diagnostic displays is also possible with a selected message. The operating
personnel can also take the message directly from the erroneous
operands and react immediately without having to perform any
other operations on the HMI device. WinCC flexible allows this
function on the Windows CE-based devices /TP/MP 270/277,
MP370/377 and on PC Runtime systems. The function is available as of version 6.0 for WinCC/ProAgent.
Unit overview
The units overview displays all technological units and the
respective sub-units (system/machine components) in table
form. In this display, the user is able to recognize, for example,
which operating mode or which status the respective unit is in.
The operating mode can be changed by the user if required.
4
Faulty units are marked with attributes.
Standardized user interface with standard displays
• Message display
• Unit overview
• Diagnostics detail display
• Motion display
• Sequencer operating display
The displayed image contents are related to the previously
selected units or messages. This means that the proper. contextsensitive diagnostics display can be called up based on a
message or a selected technological unit.
Siemens ST 80 · 2009
4/89
© Siemens AG 2008
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Function (continued)
Diagnostics detail display
Sequencer operating display
The diagnostic detail display shows the faulty operands at the
time of origination of a process error. As an option, current status
information can also be displayed. The diagnostics results are
either displayed in a ladder diagram (LAD), statement list (STL),
or in a clearly arranged signal list overview. The output of the
operands depends on the display format with symbols and
comments from the S7 symbol table. Only the operands that
cause the fault are displayed and marked with a highlighted
attribute. Switching to a display that calls up the current status of
all operands in the controller is also possible.
The sequencer operating display supports sequencer control.
This makes functions such as initializing and acknowledging
sequencers, activating/deactivating individual steps and operating mode settings possible analog to the status/control in
S7-GRAPH. The steps are output to a list with step number/
name. Attributes for identifying an active/faulty step give the
operating personnel an overview of the current status of the step
sequence.
Motion display
Sequencer diagnostic display
The motion display is used for supported fault rectification. Every
motion line contains a comment line that describes the motion
(e.g. x-axis), two actions for implementing the motion, response
concerning the actuation of a motion and information on the respectively achieved end positions (max. 16).
WinCC flexible/ProAgent and WinCC/ProAgent1) also offer capabilities for graphic monitoring and sequencer diagnostics.
This gives the user the ability to monitor active/faulty steps as
well as the fault cause, e.g. faulty transition conditions, simultaneously on the HMI device.
4
The motion itself is controlled with softkeys on the side of
SIMATIC Panels and Multi Panels. For time-critical motions, the
actuation can be done directly through inputs of the controller
(depending on the capabilities of the target hardware: 24 V
direct keys, DP direct keys via PROFIBUS).
4/90
Siemens ST 80 · 2009
1)
WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1
(OCX is delivered as of S7-GRAPH 5.1)
© Siemens AG 2008
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Technical specifications
WinCC/ProAgent
WinCC flexible /ProAgent
• Can be used in conjunction with
programmable controllers
SIMATIC S7:
S7-300/S7-400; WinAC
SIMATIC S7:
S7-300/S7-400; WinAC
• Types of connection
SIMATIC S7 Protocol Suite:
MPI, PROFIBUS DP, Industrial Ethernet, TCP/IP
SIMATIC S7 Protocol Suite: MPI, PROFIBUS DP,
PROFINET IO, Industrial Ethernet, TCP/IP
Modification of HMI diagnostics data
management in RT
WinCC/ProAgent V6.0 and higher
No
Unit overview
Yes
Yes
Message display
Yes
Yes
Sequencer operating display
Yes
Yes
Diagnostics detail display
Yes
Yes
• Display
STL/LAD/signal list
Yes/Yes/Yes
Yes/Yes/Yes
• Display of operands with symbol
and comment
Yes
Yes
Criteria analysis
When fault occurs/current status/can be archived When fault occurs/current status
Interfaces
Functionality
4
Motion display
• Number of viewable
movements
6
6
• Directions of motion
2
2
• Number of viewable
end positions per movement
16
16
de/en/fr; included in scope of delivery
de/en/fr/it/es; included in scope of delivery
HMI software
WinCC V6.2
(ProAgent V6.0 + SP4)
WinCC flexible 2008
Operating system:
Configuration
WinCC/ProAgent V6.0 + SP4:
Windows 2000 + SP3, Windows XP + SP2, Windows Server 2003 + SP1
Windows XP SP2/SP3
Windows Vista Business
Windows Vista Ultimate
Operating system
Runtime
WinCC/ProAgent V6.0 + SP4:
Windows 2000 + SP3, Windows XP + SP2, Windows Server 2003 + SP1
WinCC flexible/ProAgent for SIMATIC Panels:
WinCC flexible/ProAgent for WinCC flexible
Runtime:
Windows XP SP2/SP3
Windows Vista Business
Windows Vista Ultimate
STEP 7
V5.3 and higher
V5.3 and higher
• S7-GRAPH
V5.3 and higher
V5.2 + SP3 and higher
• S7-PDIAG
V5.1 and higher
V5.1 and higher
• S7-HiGraph
No
V5.3 and higher
Type of delivery
(one license is required for each target
hardware)
CD-ROM/
Runtime license
Runtime license
Documentation
In electronic format
Requirements
Siemens ST 80 · 2009
4/91
© Siemens AG 2008
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Ordering data
Order No.
SIMATIC WinCC/ProAgent
Software option package for
process error diagnosis based on
S7 GRAPH V5 and higher and S7
PDIAG V5 and higher, functional
enhancement for SIMATIC
WinCC, electronic documentation in English, French and
German; functions and standard
screens for use on a PC (resolution 1024 x 768 pixels) and
Panel PC 577/677/877 15“
(resolution 1024 x 768 pixels) in
English, French and German,
runtime license (single license)
WinCC version:
4
• V7.0, V6.2 (ProAgent V6.0 SP4)
6AV6 371-1DG06-0EX0
Upgrade
• to V6.0 (SP4)
6AV6 371-1DG06-0EX4
SIMATIC WinCC flexible/
ProAgent
Software option package for
process error diagnosis based on
S7 PDIAG V5.1 and higher, S7
GRAPH V5.2 + SP3 and higher;
S7 HiGRAPH V5.3 and higher.
Functional enhancement for
SIMATIC WinCC flexible; electronic documentation in English,
French, German, Italian and
Spanish
• WinCC flexible/ProAgent for D
SIMATIC Panels
Runtime license (Single License) executable on TP/OP/MP
270/277, MP 370/377
6AV6 618-7DB01-3AB0
• WinCC flexible /ProAgent for D
WinCC flexible Runtime
Runtime license (single license)
6AV6 618-7DD01-3AB0
Documentation (must be ordered separately)
SIMATIC HMI Manual Collection B
6AV6 691-1SA01-0AX0
Electronic documentation, on
CD-ROM
5 languages (English, French,
German, Italian, Spanish);
contains: all currently available
user manuals, manuals and
communication manuals for
SIMATIC HMI
B) Subject to export regulations: AL: N and ECCN: EAR99S
D) Subject to export regulations: AL: N and ECCN: 5D992B1
■
4/92
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Complete PC Systems
5/2
5/2
Embedded PC Systems
SIMATIC Panel PC 477B-HMI,
-RTX, -HMI/RTX
5/6
HMI Packages with WinCC flexible
and WinCC
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Complete PC Systems
Embedded PC systems
SIMATIC Panel PC 477B HMI, RTX, HMI/RTX
■
HM
■ Application
Overview
The SIMATIC Panel PC 477B is the perfect combination of the
ruggedness of an embedded platform and the openness of a
PC:
It offers the flexibility for integrating various tasks of an
automation solution on a hardware device.
The fan and hard disk free design of the Panel PC permits use of
the solution directly on the machine in a rugged environment.
The Ethernet and PROFIBUS/PROFINET interfaces allow the
system to be integrated in existing automation environments
(SIMATIC world, Siemens drive systems).
The Panel PC 477B is the platform, where the following criteria
are to be met for the automation solution:
• Compact, rugged and maintenance-free
• Integration of various tasks such as visualization, control or
data processing on the same hardware
• Utilization of application-specific hardware and software
• Machine-oriented application
5
• Quick start in automation solutions with Embedded
Automation
- SIMATIC WinCC flexible RT preinstalled and ready to switch
on (Panel PC 477B HMI) or SIMATIC WinCC flexible and
SIMATIC WinAC RTX preinstalled and ready to switch on
(Panel PC 477B HMI/RTX)
- PROFIBUS and Industrial Ethernet pre-configured for use in
a SIMATIC environment
- Configuration and programming with SIMATIC WinCC
flexible ES and SIMATIC STEP 7 via Industrial Ethernet or
PROFIBUS
• Rugged operation
- Hard-disk-free operation based on Compact Flash card
(from 2 GB CF card) and Windows XP embedded
- Operation without fan
• Flexibility of a PC-based automation environment
- Open for additional PC applications
- Can be expanded with PC/104+ cards
- Connection option for USB devices, flat panel monitor or
screen
- Use of WinAC ODK with SIMATIC WinAC RTX
• Data retention for WinAC RTX without uninterruptible power
supply (UPS)
5/2
Siemens ST 80 · 2009
© Siemens AG 2008
HMI Complete PC Systems
Embedded PC systems
SIMATIC Panel PC 477B HMI, RTX, HMI/RTX
■ Technical specifications
■ Ordering data
6ES7 676 and 6AV7 85
Order No.
Versions for "Embedded Automation", TIA applications
(preferred versions from stock)
General features
D
6ES7 676 - 7 B A 0 0 - 0 7 7 0
Processor
Intel Pentium M technology; Intel
Celeron M 1.0 GHz, Intel Pentium
M 1.4 GHz
SIMATIC Panel PC 477B
embedded
Memory type
DDR2-RAM
Main memory
1 GB, 2 GB
Free slots
3 x PC/104 (over spec. expansion
frame)
Celeron M 1.0 GHz processor,
main memory 1 GB DDR2
SDRAM,
power supply 24 V DC,
PROFIBUS DP interface
Operating system
Windows XP Embedded
Front panels
Additional OS information
Language: EN/DE
• 12" TFT Touch
1
SIMATIC Software
Optional with pre-installed bundle
software SIMATIC WinCC flexible
or WinCC flexible/WinAC RTX
• 12" TFT Key
2
• 15" TFT Touch
3
• 15" TFT Key
4
• 19" TFT Touch
6
Drives
Floppy drive
Optional via external USB floppy
drive
Optical drives
Possible as external drive via USB
Hard disk/mass storage
Compact Flash Drive with 2 GB or
4 GB
Interfaces
Graphics interface
DVI-I can be used for additional
display device (only VGA via
adapter); color depth 32 bits,
graphics memory up to 128 MB,
resolution based on integrated
display
Connection for keyboard/mouse
USB / USB
Serial interface
COM1: 1 x V.24 (RS232)
PROFIBUS/MPI
Onboard, floating, max. 12 Mbit/s,
no plug-in card required, CP5611compatible, not retrofittable
PROFINET
3 x RJ45, CP1616-compatible; not
retrofittable
USB
1 x on front, 4 x on reverse, USB
2.0 (500 mA)
Ethernet
Onboard, 2 x 10/100/1000 Mbit
(RJ45 with/without PROFIBUS),
1 x 10/100/1000 Mbit (RJ45 with
PROFIBUS), no plug-in card
required
Multimedia
No
Supply voltage
24 V DC
Mass storage
• CompactFlash 2 GB
C
• CompactFlash 4 GB
D
• With Windows XP embedded
operating system (EN/DE)
preinstalled
A
With operating system and HMI,
Windows XP embedded preinstalled, WinCC flexible RT (incl.
archives/recipes) preinstalled
• Number of tags 128 PT
C
• Number of tags 512 PT
D
• Number of tags 2048 PT
E
With operating system and
HMI/RTX (DP)
Windows XP embedded preinstalled, WinCC flexible RT (incl.
archives/recipes) preinstalled,
WinAC RTX preinstalled and
configured for PROFIBUS
• Number of tags 128 PT
F
• Number of tags 512 PT
G
• Number of tags 2048 PT
H
Monitoring functions
Temperature
Yes
Watchdog
Yes
Status LEDs
Yes (rear side)
Front side according to EN 60529
IP65 (front side) according to
EN 60529 and NEMA4
Ambient conditions
Vibration load during operation
Tested according to DIN IEC
60068-2-6: 10 - 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/s² (1 g)
Shock loading during operation
Tested according to DIN IEC
60068-2-7: 50 m/s² (5 g), 30 ms,
100 shocks
Relative humidity
Tested according to DIN IEC
60068-78, DIN IEC 68-2-30: 5% to
80% at 25 °C (no condensation)
Maximum permissible installation
angle +/-
30° over vertical
Ambient temperature during
operation
+5 °C to +50 °C in maximum
configuration; no fan
Certifications & standards
Approvals
CE, cULus (508)
EMC
CE, 55022A, EN 61000-6-4,
EN 61000-6-2
Siemens ST 80 · 2009
5/3
5
© Siemens AG 2008
HMI Complete PC Systems
Embedded PC systems
SIMATIC Panel PC 477B HMI, RTX, HMI/RTX
■ Ordering data (continued)
Order No.
Order No.
Further Panel PCs as build to order versions
Further Panel PCs as build to order versions (continued)
(max. delivery time 15 working days)
(max. delivery time 15 working days)
SIMATIC Panel 477B embedded D
6AV7 85 7 - 0 A 7 7 7 - 7 7 A 0
24 V DC power supply
Software packages
Front panels
Preinstalled with CF card
6AV7 85 7 - 0 A 7 7 7 - 7 7 A 0
• 12" TFT Touch
1
• With 2 GB CF card
3
• 12" TFT Key
2
• With 4 GB CF card
4
• 15" TFT Touch
3
• 15" TFT Key
4
With Windows XP embedded
operating system (EN/DE) preinstalled
• 19" TFT Touch
6
B
• Celeron M 1.0 GHz
D
• Celeron M 1.0 GHz with
PROFIBUS DB12
E
With operating system and RTX
Windows XP embedded (EN/DE)
preinstalled, WinAC RTX preinstalled and preconfigured for
PROFIBUS (DP) or PROFINET
(PN)
• Celeron M 1.0 GHz with
PROFINET
F
• WinAC RTX (DP) configured for
PROFIBUS
C
• Pentium M 1.4 GHz
G
• WinAC RTX (PN) configured for
PROFINET
K
• Pentium M 1.4 GHz with
PROFIBUS DB12
H
• Pentium M 1.4 GHz with
PROFINET
J
Processor
5
SIMATIC Panel 477B embedded D
With operating system and HMI,
Windows XP embedded preinstalled, WinCC flexible RT (incl.
archives/recipes) preinstalled
• Number of tags 128 PT
D
• 1 GB DDR2 SDRAM
2
• Number of tags 512 PT
E
• 2 GB DDR2 SDRAM
3
• Number of tags 2048 PT
F
Main memory
Second CompactFlash slot
fitted (externally accessible)
- Not fitted
0
- With CF card 2 GB
3
- With CF card 4 GB
4
With operating system and
HMI/RTX (DP)
Windows XP embedded preinstalled, WinCC flexible RT (incl.
Archives/Recipes) preinstalled,
WinAC RTX preinstalled and
configured for PROFIBUS
• Number of tags 128 PT
G
• Number of tags 512 PT
H
• Number of tags 2048 PT
J
• With operating system and
HMI/RTX (PN)
Windows XP embedded preinstalled, WinCC flexible RT (incl.
Archives/Recipes) preinstalled,
WinAC RTX preinstalled and
configured for PROFINET
D) Subject to export regulations: AL: N and ECCN: 5D992B1
5/4
Siemens ST 80 · 2009
• Number of tags 128 PT
L
• Number of tags 512 PT
M
• Number of tags 2048 PT
N
© Siemens AG 2008
HMI Complete PC Systems
Embedded PC systems
SIMATIC Panel PC 477B HMI, RTX, HMI/RTX
■ Ordering data (continued)
Order No.
Please note:
The scope of supply of the Panel PC 477B mainly comprises the
Panel PC and a software pack that contains the CompactFlash
card with preinstalled and configured software as well as all the
necessary license keys. After the CompactFlash card has been
inserted in the (internal) slot provided, the unit is ready for
switching on.
Accessories
Cover foil for Panel
PCs 477/577/677/877
For protecting the touch screen
against dirt/scratches
• for 12" Touch
6AV7 671-2BA00-0AA0
• for 15" Touch
6AV7 671-4BA00-0AA0
Note:
• for 19" Touch
6AV7 672-1CE00-0AA0
Labeling foil for Panel
PCs 477/577/677/877
6AV7 672-0DA00-0AA0
Other complete turnkey solutions (the software is already
installed and configured) on Microbox PC basis can be found
under SIMATIC PC based Control.
For labeling softkeys and function
keys, blank, supplied in sets of 10
Touch pen
A
6AV7 672-1JB00-0AA0
Undetachable pen for operation
of the touch devices, mounting of
the support on the control cabinet
Expansion components
SIMATIC PC/PG DiagMonitor
V4.0
6ES7 648-6CA04-1YX0
5
Software tool for monitoring
SIMATIC PCs,
incl. manual, on CD-ROM
(German/English)
SIMATIC PC Image Creator
V2.1
A
6ES7 648-6BA02-1YX0
A
6ES7 648-6AA02-1YX0
A
6ES7 648-0DC40-0AA0
A
6FC5 235-0AA05-1AA2
A
6AV6 671-3AH00-0AX0
Software tool for data backup for
SIMATIC PCs, incl. manual, on
CD-ROM (Eng/Ger/Fr/Sp/It)
SIMATIC PC Partition Creator
V2.1
Software tool for hard-disk partitioning for SIMATIC PCs, incl.
manual, on CD-ROM
(Eng/Ger/Fr/Sp/It)
SIMATIC PC USB FlashDrive
2 GB, USB 2.0, metal enclosure,
bootable
3.5" disk drive, USB
With 1 m connecting cable
Industrial USB Hub 4
4 x USB 2.0, IP65 for control
cabinet door or DIN rail
Compact Flash Card
• 2 GB
A
6ES7 648-2BF01-0XF0
• 4 GB
A
6ES7 648-2BF01-0XG0
Expansion kit PC/104
A
6AG4 070-0BA00-0XA0
For integration of PC/104 modules
(packing unit contains 6
expansion frames)
A) Subject to export regulations: AL: N and ECCN: EAR99H
Siemens ST 80 · 2009
5/5
© Siemens AG 2008
HMI Complete PC Systems
HMI Packages
HMI packages with WinCC flexible and WinCC
■ Overview
5
SIMATIC Panel PC with SIMATIC WinCC flexible
• SIMATIC Panel PC packages with WinCC flexible are an
innovative solution for simple visualization tasks directly at the
machine in the field of HMI.
• This package can only be supplied if a Panel PC is ordered
together with the WinCC flexible Runtime software. It cannot
be ordered subsequently.
• In combination with the Panel PC 477B there are turn-key
solutions, i.e. the runtime software is already preinstalled.
SIMATIC Panel PC with SIMATIC WinCC
• The SIMATIC Panel PC packages with WinCC make it easy to
order all the components required for an HMI solution on the
basis of a Panel PC.
• This package can only be supplied if a Panel PC is ordered
together with the WinCC software. It cannot be ordered subsequently.
• In conjunction with the Panel PC 477B, there are turnkey
solutions as WinCC Standard Clients.
5/6
Siemens ST 80 · 2009
■ Benefits
•
•
•
•
Easy to order
Cost savings in contrast to ordering components individually
Optimally tuned hardware for the SIMATIC HMI software
System-tested solution
© Siemens AG 2008
HMI Complete PC Systems
HMI Packages
HMI packages with WinCC flexible and WinCC
■ Design
SIMATIC Panel PC with SIMATIC WinCC flexible
The order configurator gives you a free choice of how the Panel
PC hardware is configured – depending on individual requirements for display and system performance.
Customers must install the desired WinCC flexible Runtime
software and the communication hardware and software
themselves. The WinCC flexible Runtime software is supplied
with the devices. The package also contains the runtime options
for WinCC flexible/Archives and WinCC flexible/Recipes.
Runtime licenses are required for WinCC flexible Runtime. One
of the offered licenses can be selected depending on the
number of Power Tags required.
■ Ordering data (continued)
SIMATIC WinCC flexible
Package1) 2)
(incl. Archives and Recipes)
Order No.
D
6AV6 623 - 2 7 A 0 0 - 0 A A 0
WinCC flexible 2008 Runtime
• 128 Power Tags
B
• 512 Power Tags
D
• 2 048 Power Tags
F
• 4 096 Power Tags
G
SIMATIC WinCC Package1)
D
6AV6 382 - 2 7 A 0 6 - 2 A X 0
WinCC V6.2 Runtime2)
• 128 Power Tags
C
The term PowerTags is used exclusively to describe process
variables that have a process link to the controller.
• 256 Power Tags
D
• 1 024 Power Tags
E
Variables without process link, constant limit values of variables,
and messages are also available for additional system
performance.
• 8 192 Power Tags
H
SIMATIC Panel PC with SIMATIC WinCC
The order configurator gives you a free choice of how the Panel
PC hardware is configured – depending on individual requirements for display and system performance. It is only necessary
in this case to comply with the minimum requirements that
WinCC places on the basic hardware.
Minimum configuration:
• Processor: Pentium III 933 MHz or Celeron 650 MHz or higher
• 12" or 15" display (at least 600 x 800 pixels resolution)
• Main memory min. 512 MB
• Min. 10 GB with CD-ROM
• Windows 2000 Multilanguage or Windows XP Professional
Multilanguage
For process communication, you can choose between the
on-board, CP 5611-compatible PROFIBUS interface or the
powerful modules CP 1613 for Industrial Ethernet and CP 5613
for PROFIBUS.
From the configurator for the WinCC package, another order
item can be selected that then contains the relevant WinCC
software package and the communication module.
Both order items are delivered together. Customers must install
the communication hardware and the WinCC software
themselves.
Runtime licenses are required for WinCC Runtime. One of the
offered licenses can be selected depending on the number of
Power Tags required.
The term Power Tags is used exclusively to describe process
variables that have a process link to the controller. Variables
without process link, constant limit values of variables, and
messages are also available for additional system performance.
• 65 536 Power Tags
SIMATIC WinCC Package1)
F
D
6AV6 382 - 2 7 A 0 7 - 0 A X 0
WinCC V7.0 Runtime2)
• 128 Power Tags
C
• 512 Power Tags
D
• 2 048 Power Tags
E
• 8 192 Power Tags
H
• 65 536 Power Tags
F
5
Ready-to-use Panel PC 477B as
a WinCC Standard Client
WinCC V7.0 is already installed
and set up on the 4 GB compact
flash card as a standard client.
The Panel PC 477B has a 24 V
DC power supply and has 2X
Ethernet 1 Gbit/s, 4X USB 2.0,
1x COM1 (RS232).
Available solutions:
• 15" Touch,
Celeron 1.0 GHz processor with
1 GB of main memory
6ES7 676-3DA20-0DS0
• 15" Touch,
Pentium M 1.4 GHz processor
with 2 GB of main memory
6ES7 676-3GA30-0DS0
• 19" Touch,
Celeron 1.0 GHz processor with
1 GB of main memory
6ES7 676-6DA20-0DS0
• 19" Touch,
Pentium M 1.4 GHz processor
with 2 GB of main memory
6ES7 676-6GA30-0DS0
1)
Only if ordered with a Panel PC
2)
The current version will always be supplied
D) Subject to export regulations: AL: N and ECCN: 5D992B1
Note:
For ordering data for Panel PCs and accessories, see
configurators in "SIMATIC Panel PCs“
■ More information
Additional information is available in the Internet under:
http://www.siemens.de/simatic-hmi
Siemens ST 80 · 2009
5/7
© Siemens AG 2008
HMI Complete PC Systems
HMI Packages
HMI packages with WinCC flexible and WinCC
5
■
5/8
Siemens ST 80 · 2009
© Siemens AG 2008
Industrial LCD Monitors
SIMATIC Flat Panels
■ Overview
■ Design
• Rugged aluminum front
• TFT display in following sizes:
- 12" / 800 x 600 pixels
- 15" / 1024 x 768 pixels
- 17" / 1280 x 1024 pixels
- 19" / 1280 x 1024 pixels
• 256K up to 16 million colors
• Anti-glare and hardened mineral glass screen
• Basic display or touch screen option
• 24 V DC power supply, also optional with 100-240 V AC
(50/60Hz)
• Can be located up to 5 m from the computing unit
• The Flat Panels are rugged industry-standard LCD monitors.
• They can be used in any application in which CRT monitors
are used.
• Installation
- They are equally suited to installation in the machine, in
control cabinets, consoles and gantries or in 19" racks.
- As a device with all-round IP65 protection for mounting on a
supporting arm/supporting foot
• Possible operation:
- Simple display devices without operator functionality
- Optional devices with touch control
- Rear connection of I/O devices (optional)
7
■ Benefits
• Rugged industrial design:
- High shock and vibration resistance as well as extremely
high electromagnetic compatibility make for a fail-safe and
long-lasting design
- Enclosure front in degree or protection IP65/NEMA4,
resistant against dust and humidity
- Enclosure version complete in degree of protection IP65 for
mounting on supporting arm
- Scratch-resistant, anti-glare mineral glass screen, providing
high mechanical protection against pressure and scratching
- Meets CE standard "Industry"
• Variety of versions
• No X-rays
• Lower energy requirement
• Fatigue-proof operation:
- Wide reading angle of up to 170° horizontal and vertical
- Sharp and high-contrast graphic display
- No flickering, uniform brightness
- Automatic display adjustment (Auto Adjust)
• Configuration using on-screen display (OSD)
• Small space requirement and low weight
• Long service life
■ Application
The Flat Panels are used in applications in which the PC
computer unit and operation/display unit have to be installed
separately for technical or application-specific reasons.
SIMATIC Flat
Panels can be directly connected to any PC, but are designed
especially for operation with the SIMATIC Box or SIMATIC Rack
PC.
7/2
Siemens ST 80 · 2009
The following are included in the scope of supply of the built-in
units:
• 24 V connection plug
• Power supply cable (Europe) for version with AC power pack
(power supply cables for other countries can be ordered as an
accessory)
• VGA connection cable 1.8 m (other cable lengths and DVI
cable available separately as accessories)
• USB Touch connection cables for Touch devices (other cable
lengths available separately as accessories)
• Latch fastener
• Operating instructions, 2 languages (German and English)
• CD-ROM with hardware drivers and documentation
The following are included in the scope of supply of the PRO
devices:
• 24 V connection plug
• Power supply cable (Europe) (power supply cables for other
countries can be ordered as an accessory)
• Latch fastener
• Operating instructions, 2 languages (German and English)
• CD-ROM with hardware drivers and documentation
Special functions of extended version
• Can be located up to 30 m from the computing unit
• Two rear USB interfaces
• Dimmable backlit display
• Combined AC and DC power supply
• EX22 approval for 17" and 19" devices
• Marine approvals
Flat Panel PRO 15" Touch devices
• For mounting on support arm/pedestal
• All-round IP65 protection and NEMA 4-certified
• 15" touch display
• Rugged aluminum enclosure
• Combined 24 V DC and 100-240 V AC (50/60 Hz) power
supply
• Two internal USB interfaces, one of which can be lead through
with the "USB service interface" accessory
• Can be located up to 30 m away from the computer unit
• Adaptation of the device optionally from above or below
• Direct connection to support arm systems of well-known
manufacturers (e.g. Rittal, Bernstein, Rose, Rolec)
• Supports the globally established VESA 75/VESA 100
standard for flexible installation
© Siemens AG 2008
Industrial LCD Monitors
SIMATIC Flat Panels
■ Technical specifications
Flat Panel
12"
15"
17"
19"
PRO 15"
Supply voltage
24 V DC,
optional additional
100-240 V AC
24 V DC,
optional additional
100-240 V AC
24 V DC,
optional additional
100/240 V AC
24 V DC,
optional additional
100/240 V AC
24 V DC and
100/240 V AC
Permissible frequency
range
47 - 63 Hz
47 - 63 Hz
47 - 63 Hz
47 - 63 Hz
47 - 63 Hz
Power consumption,
max.
25 VA
35 VA
55 VA
55 VA
35 VA
Anti-glare and
Yes
hardened mineral glass
screen
Yes
Yes
Yes
Yes
Line side switch
No
No
No
No
No
Can be separate from
the computer
optional up to 30 m
optional up to 30 m
optional up to 30 m
optional up to 30 m
up to 30 m
On-screen display
(OSD) configuration
Yes
Yes
Yes
Yes
Yes
Display version
12" TFT
15" TFT
17" TFT
19" TFT
15" TFT
Visible area (H x V)
in mm
246 x 184.5
304 x 228
304 x 228
376 x 301
376 x 301
Viewing angle
140° x 120°
140° x 120° (min)
170° x 170°
170° x 170°
140° x 120° (min)
Pixel pitch
0.3075 mm x 0.3075
mm
0.297 mm x 0.297 mm
0.297 mm x 0.297 mm
0.294 mm x 0.294 mm
0.297 mm x 0.297 mm
Resolution
(W x H in pixels)
800 x 600
1024 x 768
1280 x 1024
1280 x 1024
1024 x 768
Refresh rate
60 - 75 Hz
60 - 75 Hz
60 - 75 Hz
60 - 75 Hz
60 - 75 Hz
Line frequency
25 - 48 kHz
46.7 - 62.5 kHz
30 - 80 kHz
30 - 80 kHz
30 - 80 kHz
Brightness/contrast
> 350 cd/m²/450:1
> 260 cd/m²/350:1
> 300 cd/m²/300:1
> 300 cd/m²/300:1
> 260 cd/m²/350:1
Number of colors
262k
16.2 million
16.2 million
16.7 million
16.7 million
MTBF backlit display
(at 25° C, 24 hours
continuous operation)
50,000 h
50,000 h
50,000 h
50,000 h
50,000 h
Touch screen
analog-resistive,
optional
analog-resistive,
optional
analog-resistive,
optional
analog-resistive
Connection for
keyboard/mouse/
barcode reader
Yes, on the rear,
optionally via USB
Yes, on the rear,
optionally via USB
Yes, on the rear,
optionally via USB
Yes, on the rear,
optionally via USB
Yes, optionally via USB
Front side according
to EN 60529
IP65
IP65
IP65
IP65
IP65
Rear side according
to EN 60529
IP20
IP20
IP20
IP20
IP65
Certification
cULus (UL 508),
NEMA4
cULus (UL 508),
NEMA4
cULus (UL 508),
NEMA4
cULus (UL 508),
NEMA4
cULus (UL 508),
NEMA4 available soon
EMC
CE EN 55011 class A
CE EN 55011 class A
CE EN 55011 class A
CE EN 55011 class A
CE EN 55011 class A
CE mark
Yes
Yes
Yes
Yes
Yes
UL approval
Yes
Yes
Yes
Yes
Yes
Supply voltage
General features
Display
Type of operation
Degree of protection
Certifications &
standards
Standards, approvals,
certificates
Siemens ST 80 · 2009
7/3
7
© Siemens AG 2008
Industrial LCD Monitors
SIMATIC Flat Panels
■ Technical specifications (continued)
Flat Panel
12"
15"
17"
19"
PRO 15"
Vibration load during
operation
1 g (10 m/s²)
1 g (10 m/s²)
1 g (10 m/s²)
1 g (10 m/s²)
0.5 g (10 m/s²)1)
Shock loading during
operation
5 g (50 m/s²)
5 g (50 m/s²)
5 g (50 m/s²)
5 g (50 m/s²)
5 g (50 m/s²)
5 to +50 °C
5 to +50 °C
5 to +45 °C
5 to +45 °C
Ambient conditions
Temperature
• Ambient temperature 5 to +50 °C
during operation
Mounting
• Rack-mounting
No
No
No
No
No
• Front mounting
Yes (IP65)
Yes (IP65)
Yes (IP65)
Yes (IP65)
No
• Inclined position for
mounting in console
-20°/+70°
-20°/+70°
-20°/+70°
-20°/+70°
-45°/+45°
Graphics interface
Standard VGA
interface 15-pole
sub D/digital DVI-D
interface
Standard VGA
interface 15-pole
sub D/digital DVI-D
interface
Standard VGA
interface 15-pole
sub D/digital DVI-D
interface
Standard VGA
interface 15-pole
sub D/digital DVI-D
interface
Standard VGA
interface 15-pole
sub D/digital DVI-D
interface
Interface for Touch
USB (V1.1)
USB (V1.1)
USB (V1.1)
USB (V1.1)
USB (V1.1)
Optional
Optional
Optional
Optional
400 x 310 x 91
Interfaces
USB interface for touch Optional
screen
Dimensions
External dimensions
(W x H x D) in mm
400 x 310 x 61.5
483 x 310 x 54
483 x 400 x 56
483 x 400 x 56
Installation
cutout/device depth
(W x H x D) in mm
368 x 290 x 51
450 x 290 x 54
449 x 380 x 56
449 x 380 x 56
5 kg
6.4 kg
10.2 kg
10.2 kg
Weights
7
Weight, approx.
1)
With basic adapter on supporting arm: 0.5 g
7/4
Siemens ST 80 · 2009
6.7 kg
(without adapter)
© Siemens AG 2008
Industrial LCD Monitors
SIMATIC Flat Panels
■ Ordering Data
Order No.
Order No.
Standard configuration
Flat Panel Monitor
Accessories
6AV7 861- 7 7 7 7 0- 7 AA0
Display size:
• 12"
1
*
• 15"
2
1
• 17"
4
1
• 19"
3
1
• 15" PRO
5
1
Operator functionality:
• Display devices without
operator functionality
A
• Touch screen (analog/resistive)
T
1
1
Power supply
• 24 VDC
(not for Extended versions since
these always have AC and DC)
A
• 100 … 230 VAC (incl. Euro
power supply cable) and
24 VDC
B
1
1
Version
• Standard:
Can be located up to 5 m away
0
• Extended:
Can be located up to 30 m away
- Marine approvals
- Dimmable backlit display
- Ex22
1
1
Connecting cables
for all versions
• Video (VGA)
- 3.0 m
6AV7 860-0AH30-0AA0
- 5.0 m
6AV7 860-0AH50-0AA0
• Video (DVI-D)
- 3.0 m
6AV7 860-0BH30-0AA0
- 5.0 m
6AV7 860-0BH50-0AA0
• USB for optional touch screen
- 3.0 m
6AV7 860-0CH30-0AA0
- 5.0 m
6AV7 860-0CH50-0AA0
Connection cables for
Extended and PRO versions
• Cable set 10 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
A
6AV7 860-1EX21-0AA1
• Cable set 15 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
A
6AV7 860-1EX21-5AA1
• Cable set 20 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
A
6AV7 860-1EX22-0AA1
• Cable set 30 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
A
6AV7 860-1EX23-0AA1
Accessories for Flat Panel PRO 15"
1-port USB interface
* 0 with standard version,
1 with extended version
Adapter set for
Flat Panel Monitor PRO 15"
Touch
Fully enclosed Flat Panel with 15"
Touch display, IP65, AC and DC
power supply, can be mounted
separately up to 30 m, DVI and
VGA interface
Adapter set for
• Rittal CP-L
6AV7 861- 5 TB 1 0- 1 AA0
• Rose GT48/2
• Rolec taraPLUS
• Rittal CP-S
• Bernstein CS3000 coupling 48
• Rolec Quadro
• Rose GTK electronic
6AV7 674-0LX00-0AA0
7
6AV7 674-0KC00-0AA0
6AV7 674-0KB00-0AA0
Adapter set for
• VESA 100
• Rose GTN II
6AV7 674-0KD00-0AA0
Adapter set for
• VESA 75
6AV7 674-0KE00-0AA0
A) Subject to export regulations: AL: N and ECCN: EAR99H
Siemens ST 80 · 2009
7/5
© Siemens AG 2008
Industrial LCD Monitors
SIMATIC Flat Panels
■ Dimensions
H
D
10,5
Front dimensions
W+1 (cutout)
H+1 (cutout)
H
Touch panels
12"
15"
17"
19"
400
483
483
483
310
310
400
400
Installation cutout
W+1
H+1
D
Touch panels
12"
15"
17"
19"
368
450
450
450
290
290
380
380
51
55
57
57
Installation cutout for Flat Panel
310
400
Flat Panel PRO 15" Touch
7/6
Siemens ST 80 · 2009
G_ST80_XX_00350
90,85
67,85
7
W
G_ST80_XX_00238Y
W
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Overview
• The SCD 1297/1597/1997 monitors are LCD monitors in a
rugged industrial design.
• They can be used in any application in which CRT monitors
are used.
Rack-mounting version:
• Rack-mounting units (for control cabinets, control desks and
gantries)
• 19" rack-mounting units (for 19" racks)
• Desktop models only (19" display)
Type of operator control:
• Simple display devices
• Panels with touch operator control
■ Benefits
• Rugged industrial design:
- High shock and vibration resistance as well as extremely
high EMC compatibility make for a fail-safe and long-lasting
design
- Enclosure rated IP65, resistant against dust and humidity
- Mineral glass screen, high mechanical protection against
pressures and scratch resistance
- Meets CE standard "Industry"
• Variety of versions
• No X-rays
• Lower energy requirement
• Fatigue-proof operation:
- Large reading angle
- Sharp and high-contrast graphic display
- No flicker, uniform brightness
- Automatic display adjustment (Auto Adjust)
• Configuration using on-screen display (OSD)
• Small space requirement and low weight
• Long service life
■ Design
•
•
•
•
•
•
•
•
Rugged aluminum enclosure
12"/15"/19" TFT display
Anti-glare and hardened mineral glass screen
Simple display, touch screen
Line frequency 30-80 kHz
Refresh frequency 50-72 Hz
Power supply 100-240 V AC, 12 V DC and 24 V DC
Can be located up to 20 m from the computing unit
7
The industrial LCD monitors SCD 1297, 1597, 1997 come in two
rack-mounting versions:
• As rack-mounting units
(for control cabinets, control desks and gantries)
- SCD 1297/1597/1997-E – display unit only
- SCD 1297/1597/1997-ET with analog resistive touch screen
• As 19" rack-mounting units for 19" racks
- SCD 1297/1597/1997-R – display unit only
- SCD 1297/1597/1997-RT with analog resistive touch screen
Scope of delivery:
• Network connecting cable for AC power supply unit
• Connecting cables 1.8 m, 5 m, 10 m or 20 m
• Operating instructions, 2 languages (German and English)
• CD-ROM with touch drivers
Special features for switch-over from CRT monitors to LCD
monitors
• Screen diagonal:
The rough formula for LCD monitors is: "Display size in inch
plus 2", corresponds to the comparable CRT monitor size
(14" CRT equivalent to 12" LCD).
• Resolution:
When the corresponding LCD monitor is selected, make sure
that the resolution of the LCD monitor is suitable for the visualization application.
Siemens ST 80 · 2009
7/7
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Technical specifications
12" monitors
SCD 1297-E/-ET
SCD 1297-R/-RT
General features
Power supply
Power supply
110 / 230 V AC; 24 VDC as option
110 / 230 V AC; 24 V DC as option
Frequency/power consumption
47 … 63 Hz / 30 VA
47 … 63 Hz / 30 VA
Power switch
No
No
Representation
Full-screen
Full-screen
Display version
12" TFT
12" TFT
Screen diagonal
12 "
12"
Visible area (H x V) in mm
246 x 184
246 x 184
Viewing angle
120° x 100°
120° x 100°
Pixel pitch
0.31 x 0.31
0.31 x 0.31
Optimum resolution (in pixels)
800 x 600
800 x 600
Image refresh rate
50 … 72 Hz
50 … 72 Hz
Horizontal frequency
30 … 80 KHz
30 … 80 KHz
Display
2
Brightness/contrast (typical)
300 cd/m / 300:1
300 cd/m2 / 300:1
Number of colors
256 k
256 k
MTBF background illumination
(up to 50 %, at 25 °C)
50,000 h
50,000 h
Type of operation
Function keys
No
No
Membrane keyboard & piezo
mouse
No
No
Touch screen
Optional (1297-ET)
Optional (1297-ET)
IP65
IP54
0 … +40 °C
0 … +40 °C
Interface design,
analog video signal (VGA)
Yes
Yes
PS/2 interfaces for
keyboard & mouse
No
No
Serial interface for
touch screen
Optional (1297-ET)
Optional (1297-RT)
External dimensions
(W x H x D) in mm
364 x 284 x 76
483 x 266 x 80
Panel cutout/depth
(W x H x D) in mm
334.4 x 252 x 76
-
5
5
Degree of protection
7
Degree of protection in
accordance with EN 60529
Ambient conditions
Temperature
• Ambient temperature
during operation
Interfaces
Dimensions
Weight
Weight in kg
7/8
Siemens ST 80 · 2009
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Technical specifications (continued)
15" monitors
SCD 1597-E/-ET
SCD 1597-K
SCD 1597-R/-RT
General features
Power supply
Power supply
110 / 230 V AC; 24 V DC as option
110 / 230 V AC; 24 VDC as option
110 / 230 VA C; 24 V DC as option
Frequency/power consumption
47 … 63 Hz / 30 VA
47 … 63 Hz / 30 VA
47 … 63 Hz / 30 VA
Power switch
No
No
No
Representation
Full-screen
Full-screen
Full-screen
Display version
15" TFT
15" TFT
15" TFT
Screen diagonal
15"
15"
15"
Visible area (H x V) in mm
304 x 228
304 x 228
304 x 228
Viewing angle
130° x 110°
130° x 110°
130° x 110°
Pixel pitch
0.30 x 0.30
0.30 x 0.30
0.30 x 0.30
Optimum resolution (in pixels)
1024 x 768
1024 x 768
1024 x 768
Image refresh rate
50 … 72 Hz
50 … 72 Hz
50 … 72 Hz
Horizontal frequency
30 … 80 KHz
30 … 80 KHz
30 … 80 KHz
Display
2
2
Brightness/contrast (typical)
250 cd/m / 300:1
250 cd/m / 300:1
250 cd/m2 / 300:1
Number of colors
16 million
16 million
16 million
MTBF background illumination
(up to 50 %, at 25 °C)
35,000 h
35,000 h
35,000 h
Type of operation
Function keys
No
36 with LED
No
Membrane keyboard & piezo
mouse
No
Yes
No
Touch screen
Optional
No
Optional
IP65
IP65
IP54
0 … +40 °C
0 … +40 °C
0 … +40 °C
Interface design,
analog video signal (VGA)
Yes
Yes
Yes
PS/2 interfaces for
keyboard & mouse
No
Yes
No
Serial interface for
touch screen
Optional
No
Optional
External dimensions
(W x H x D) in mm
428 x 336 x 83
483 x 355 x 95
483 x 311 x 83
Panel cutout/depth
(W x H x D) in mm
394 x 306 x 83
448 x 333 x 95
-
5,5
5,5
5,5
Degree of protection
Degree of protection in
accordance with EN 60529
7
Ambient conditions
Temperature
• Ambient temperature
during operation
Interfaces
Dimensions
Weight
Weight in kg
Siemens ST 80 · 2009
7/9
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Technical specifications (continued)
19" monitors
SCD 1997-E/-ET
SCD 1997-R/-RT
SCD 19101-D/-DT
General features
Power supply
Power supply
110 / 230 V AC
110 / 230 V AC
110 / 230 V AC
Frequency/power consumption
47 … 63 Hz / 30 VA
47 … 63 Hz / 30 VA
47 … 63 Hz / 30 VA
Power switch
No
No
No
Representation
Full-screen
Full-screen
Full-screen
Display version
19" TFT
19" TFT
19" TFT
Screen diagonal
19"
19"
19"
Visible area (H x V) in mm
359 x 287
359 x 287
359 x 287
Viewing angle
170° x 170°
170° x 170°
170° x 170°
Pixel pitch
0.28 x 0.28
0.28 x 0.28
0.28 x 0.28
Optimum resolution (in pixels)
1280 x 1024
1280 x 1024
1280 x 1024
Image refresh rate
30 … 100 Hz
30 … 100 Hz
30 … 100 Hz
Horizontal frequency
50 … 97 KHz
50 … 97 KHz
50 … 97 KHz
Display
2
2
Brightness/contrast (typical)
270 cd/m / 400:1
270 cd/m / 400:1
270 cd/m2 / 400:1
Number of colors
16 million
16 million
16 million
MTBF background illumination
(up to 50 %, at 25 °C)
50,000 h
50,000 h
50,000 h
Type of operation
Function keys
No
No
No
Membrane keyboard & piezo
mouse
No
No
No
Touch screen
Optional
Optional
Optional
IP65
IP54
IP20
0 … +40 °C
0 … +40 °C
0 … +40 °C
Interface design,
analog video signal (VGA)
Yes
Yes
Yes
PS/2 interfaces for
keyboard & mouse
No
No
No
Serial interface for
touch screen
Optional/serial
Optional/serial
Optional/serial
External dimensions
(W x H x D) in mm
481 x 385 x 89
483 x 400 x 8
465 x 444 x 91
(stand depth 240)
Panel cutout/depth
(W x H x D) in mm
450 x 353.4 x 89
-
465 x 444 x 91
(stand depth 240)
10
10
7
Degree of protection
7
Degree of protection in
accordance with EN 60529
Ambient conditions
Temperature
• Ambient temperature
during operation
Interfaces
Dimensions
Weight
Weight in kg
7/10
Siemens ST 80 · 2009
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Ordering data
Order No.
Order No.
Standard configuration
LCD monitors
Accessories
6AV8 101- 7 7 7 0 0- 0 7 A1
Monitor/type
Connecting cable
• Video + Touch
• 12" TFT (SCD 1297)
0
- 1.8 m
6AV8 107-0BA00-0AA0
• 15" TFT (SCD 1597)
1
- 5.0 m
6AV8 107-0DA00-0AA0
• 19" TFT (SCD 1997)
3
- 10.0 m
6AV8 107-0FA00-0AA0
- 20.0 m
6AV8 107-0HA00-0AA0
Rack-mounting version:
• Rack-mount unit
B
• 19“ rack unit (R)
C
• Video
- 20.0 m
6AV8 107-0HB00-0AA0
• Video + 2*PS/2
Operator functionality:
• Display devices without
operator functionality
A
• Touch (T)
B
6AV8 107-0BC00-0AA0
6AV8 107-0DC00-0AA0
• Video + X27
Connecting cable:
• Video + Touch
- 1,8 m
B
- 5,0 m
D
- 10,0 m
F
- 20,0 m
H
- 10.0 m
6AV8 107-0FC00-0AA0
- 20.0 m
6AV8 107-0HC00-0AA0
6AV8 107-1AA00-0AA0
100 … 240 V AC
power supply unit
for SCD monitor (with
bracket + power supply cable)
Desktop models
• Video (not for Keyboard and
Touch operator functionality)
- 20,0 m
- 1.8 m
- 5.0 m
19" LCD monitors
J
SCD 19101-D, desktop model
(design identical to SCD 1898-I)
- 1,8 m
L
- 5,0 m
N
SCD 19101-DT, desktop model
(design identical to the successor
of SCD 1898-IT, but with USB
Touch)
• Video + 2*PS/2 (for Keyboard
operator functionality only)
19" Touch LCD monitors
• Video + X27 (for Keyboard
operator functionality only)
- 10,0 m
Q
- 20,0 m
S
A
6GF6 220-1DA01
A
6GF6 220-1DB01
7
A) Subject to export regulations: AL: N and ECCN: EAR99H
Siemens ST 80 · 2009
7/11
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Dimensions
364
M3x10
ACTIVE AREA
246x184,5
245
170
Power
Power
supply
XGA
284
332
240
Operating elements
262
229
170
A
Touch
40
341.4
307
240
View A
Switchboard cutout
G_ST80_EN_00023
76
4
SCD 1297-E, SCD 1297-ET
483
465
40
7
View A
Power
Power
supply
Operating
elements
XGA
ACTIVE AREA
246x184,5
Touch
190,4
A
76
G_ST80_EN_00025
4
SCD 1297-R, SCD 1297-RT
7/12
Siemens ST 80 · 2009
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Dimensions (continued)
428
44,5
406
393
360,5
120,7
M4x10
ACTIVE AREA 304x228
Power
27,5
82,5
4
XGA
Power
Supply
Touch
290
314
279
107
Operating
elements
336
A
397
Switchboard cutout
G_ST80_XX_00026
View A
SCD 1597-E, SCD 1597-ET
View A
483
39
465
27
7
ACTIVE AREA 304x228
Power
Power
Supply
Unit
XGA
Operating
elements
310,3
234,9
A
Touch
44,5
G_ST80_XX_00028
82,5
4
SCD 1597-R, SCD 1597-RT
Siemens ST 80 · 2009
7/13
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Dimensions (continued)
Switchboard cutout
459
417
400
200
101
459
450
400
200
481
362
d=5(16x)
362,4
240
353,4
220 V AC
VGA
290
384,4
240
338
362,4
Operating
elements
Touch
S-VHS
FBAS
4
G_ST80_XX_00029
85
SCD 1997-E/ET
483
465
101
AC 220 V
VGA
120,6
323,8
399,2
7
Touch
S-VHS
FBAS
4
G_ST80_XX_00030
85
SCD 1997-R/RT
7/14
Siemens ST 80 · 2009
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
■ Dimensions (continued)
465
15"
380
240
287,6
393
G_ST80_XX_00031
51
444
47
20
393
91
5"
160
SCD 19101-D/DT
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/industrial-lcd
7
Siemens ST 80 · 2009
7/15
© Siemens AG 2008
Industrial LCD Monitors
SCD Monitors
7
■
7/16
Siemens ST 80 · 2009
© Siemens AG 2008
Fully enclosed HMI units
8/2
Introduction
8/6
Accessories for Fully enclosed
HMI units
1-port USB interface
Adapter sets
8/6
8/7
Siemens ST 80 · 2009
© Siemens AG 2008
Fully enclosed HMI units
Introduction
■ Overview
■ Benefits
•
•
•
•
•
•
•
•
•
•
The new SIMATIC Fully Enclosed HMI devices have been
specially designed for mounting on a supporting
arm/supporting foot. Thanks to their extremely rugged design,
the devices are ideal for industrial applications even in harsh
environments.
The following are available as SIMATIC Fully Enclosed HMI
device:
• SIMATIC MP 377 PRO 15"
• SIMATIC THIN CLIENT PRO 15"
• SIMATIC Flat Panel PRO 15"
8
8/2
Siemens ST 80 · 2009
For direct mounting on supporting arm/supporting foot
All-round protection in IP65/NEMA 4
Low depth and weight of the device
Connection of the device optionally from above or below
Total flexibility in the selection of supporting arm components
thanks to direct connection to well-known supporting arm
manufacturers
Supports the globally established VESA 75/VESA 100
standard
Service-friendly – device must does not have to be removed
from the supporting arm for servicing or replacing memory
cards.
Rugged and extremely compact aluminum enclosure
Functionally 100%-compatible with the field-proven built-in
units
Standard connecting cables can be used
© Siemens AG 2008
Fully enclosed HMI units
Introduction
■ Application
The SIMATIC HMI PRO (PRO = protected) devices have been
designed for mounting on a support arm/pedestal. Thanks to
their rugged aluminum enclosures, the SIMATIC HMI PRO
devices have full IP65 protection and are also suitable for use in
harsh environments. The separation of HMI and control cabinet
allows flexible design concepts. The new SIMATIC HMI PRO
devices are used wherever the HMI device cannot be installed
direct in the control cabinet due to restricted space, or whenever
an operator unit is required direct at the machine. The devices
stand out not only due to their compact and appealing industrial
design, but also due to their refined mechanical features. This
enables the device to be connected to the support arm system
optionally from above or below. A host of support arm systems
from well-known manufacturers are supported here.
The SIMATIC HMI PRO devices are also suitable for connection
to systems in accordance with VESA 75 and VESA 100.
The SIMATIC HMI PRO devices are extremely light-weight at
between 6.5 kg and 8 kg (depending on the device) and can
thus be installed quickly and easily.
All the devices are fan-free, and only standard connecting
cables are used.
The SIMATIC Multi Panel 377 PRO can be used wherever
operation and monitoring of machines and plants are required.
As an especially high-performance device, the Multi Panel is
suitable for demanding HMI tasks. However, in addition to
visualization, the devices can also handle other automation
tasks such as providing the platform for a software PLC.
The industrial SIMATIC Flat Panel Monitor PRO is used wherever
the operator unit and the computer unit have to be set up
separately from each other. In the fully enclosed version, the Flat
Panel can be located up to 30 m from the computing unit/IPC.
The SIMATIC THIN CLIENT PRO is ideal as a second, low-cost
operator station for terminal and web client applications.
■ Design
General
• Degree of protection IP65 (front and rear)1)
• Degree of protection NEMA 4 (front and rear)
• Die-cast aluminum housing
• Compact design with low mounting depth
• 15.1" TFT color display, 1024 x 768 pixels (XGA)
• Resistive analog touch screen
• Terminals for 24 V DC power supply
Flat Panel PRO
• Additionally 230 V AC power supply
Expansion components
1-port USB
• Accessible without tools
• For later installation in the housing
• Extension of the internal USB interface externally
• Optionally mountable at top or bottom
• Undetachable protective cover
Adapter sets
The SIMATIC HMI PRO devices can be mounted on different
supporting arm systems of the companies Rittal, Rose, Rolec
and Bernstein using adapter plates. There are also connection
options for systems in accordance with the VESA 75 and
VESA 100 standard.
1)
The degree of protection für complete unit depends on selected support
arm system.
Note:
Further information can be found under
"Expansion components".
■ Function
• SIMATIC MP 377 PRO
• SIMATIC THIN CLIENT PRO: Operator panel for terminal and
web client applications
• SIMATIC Flat Panel PRO: Industrial monitor with touch functionality, can be located up to 30 m from the operator control unit
(as with Flat Panel Extended)
Siemens ST 80 · 2009
8/3
8
© Siemens AG 2008
Fully enclosed HMI units
Introduction
■ Integration
Integral interfaces SIMATIC MP 377 PRO:
• 2 x Ethernet
The integral Ethernet interfaces are used for IT communication
and for data exchange with programmable controllers such as
SIMATIC S7
• PROFIBUS/MPI (RS 485/ RS 422)
The floating PROFIBUS interface (12 Mbit/s) is used for
connecting distributed field devices or for connecting to
SIMATIC S7
• Further interfaces
2 USB 2.0 interfaces (Universal Serial Bus), one Compact
Flash Card interface and one SD/MMC slot are available for
connecting further I/O devices.
Integral interfaces SIMATIC THIN CLIENT PRO:
• 1 x Ethernet interface
For operating on PROFINET and Ethernet networks
• 1 x USB interface
For connecting mouse and keyboard as external input
devices
Integral interfaces SIMATIC Flat Panel PRO:
• 1 x standard VGA interface, 15-pin SUB-D
• 1 x digital DVI-D interface
• 1 x Ethernet interface
• 1 x USB interface up to a distance of 30 m from the computing
unit
• 2 x USB interfaces for connecting local peripherals I/O
(e.g. mouse, keyboard) or mass storage devices such as
USB sticks
Mechanical integration
The SIMATIC HMI PRO devices can be mounted direct on the
adapter head of the desired support arm system using the basic
adapter supplied and an adapter plate to be ordered separately.
The basic adapter is attached to the device optionally from
below or from above. The connecting cables are run through the
supporting arm.
■ Technical specifications
SIMATIC MP 377 PRO
SIMATIC Flat Panel Monitor PRO
Overall device IP65/enclosure type Overall device IP65/enclosure type Overall device IP65/enclosure type
4x/type 12 (indoor use only)
4x/type 12 (indoor use only)
4x/type 12 (indoor use only)
Weight
7.5 kg
6.5 kg
6.7 kg
Dimensions (L x W x D)
400 mm x 310 mm x 98 mm
400 mm x 310 mm x 90.85 mm
400 mm x 310 mm x 90.85 mm
Inclination angle
+/- 45° from the vertical
+/- 45° from the vertical
+/- 45° from the vertical
Ambient temperature
0 °C to 45 °C
0 °C to 45 °C
0 °C to 45 °C
Power supply
24 V DC
24 V DC
24 V DC and 230 V AC combined
■ Ordering data
8
SIMATIC THIN CLIENT PRO
Degree of protection
Order No.
SIMATIC Multi Panel 377
PRO 15"
6AV6 644-2AB01-2AX0
SIMATIC THIN CLIENT
PRO 15"
6AV6 646-2AB21-2AX0
SIMATIC Flat Panel
PRO 15" Touch
6AV7 861-5TB10-1AA0
Order No.
Accessories
1-port USB interface
6AV7 674-0LX00-0AA0
Adapter set for
• Rittal CP-L
6AV7 674-0KC00-0AA0
Adapter set for
• Rose GT48/2
• Rolec taraPLUS
• Rittal CP-S
• Bernstein CS3000 Coupling 48
• Rolec Quadro
• Rose GTK electronic
6AV7 674-0KB00-0AA0
Adapter set for
• VESA 100
• Rose GTN II
6AV7 674-0KD00-0AA0
Adapter set for
• VESA 75
Scope of supply:
A basic adapter is included for connection to adapter set. An
additional adapter set must be ordered for connecting with the
support arm system.
8/4
Siemens ST 80 · 2009
6AV7 674-0KE00-0AA0
© Siemens AG 2008
Fully enclosed HMI units
Introduction
■ Dimensions
■ More information
Additional information is available in the Internet under:
400
http://www.siemens.com/hmi
SIMATIC Multi Panel
Note:
310
Do you a require specific modification or extension to the
products described here? You will find information about
additional, generally available sector-specific products, as well
as about options for customer-specific modification and
adaptation under "Customized products".
67,85
G_ST80_XX_00351
98,5
MP 377 PRO 15" Touch
400
310
SIMATIC THIN CLIENT
8
G_ST80_XX_00350
67,85
90,85
THIN CLIENT PRO 15" Touch/ Flat Panel 15" Touch
Siemens ST 80 · 2009
8/5
© Siemens AG 2008
Fully enclosed HMI units
Accessories for Fully enclosed HMI units
1-port USB interface
■ Overview
■ Integration
• The USB interface is used for connecting external peripheral
devices to the MP 377 PRO, the THIN CLIENT PRO and the
Flat Panel PRO.
• USB peripheral devices can thus be connected and operated
without opening the device
• Extension of the internal USB interface externally
Suitable for SIMATIC MP 377 PRO, SIMATIC THIN CLIENT PRO,
SIMATIC Flat Panel PRO.
■ Ordering Data
■ Design
Installation of the USB interface is especially practical if external
input devices or mass storage units have to be frequently
connected to the SIMATIC HMI PRO device.
• The USB interface can be mounted optionally at the top or
bottom of the device.
• Use of the USB interface increases the availability of the
system to be operated. The rear panel of the SIMATIC HMI
PRO device no longer has to be opened in order to connect to
the peripherals. This enables uninterrupted operation of the
device.
The USB interface offers the following benefits:
• Accessible without tools
• For later installation in the housing
• Optionally mountable at top or bottom
• IP65 when the protective cover is closed
• Undetachable protective cover
8
8/6
The USB interface is suitable for connecting, for example:
• Mouse
• Keyboard
Siemens ST 80 · 2009
1-port USB
Order No.
6AV7 674-0LX00-0AA0
© Siemens AG 2008
Fully enclosed HMI units
Accessories for Fully enclosed HMI units
Adapter sets
■ Overview
• The adapter sets are required for connecting the SIMATIC HMI
PRO device with the support arm head of the relevant support
arm system
• Thanks to direct connection of the support harm head to the
device, there is complete flexibility in the choice of support
arm components
• There are adapter sets available for Rittal, Rose, Rolec and
Berstein, and for the systems VESA 75 and VESA 100.
■ Integration
The adapter sets are connected to the SIMATIC HMI PRO
devices using the basic adapter. The support arm head is
connected direct on the adapter plate.
■ Ordering data
Adapter set for
Order No.
6AV7 674-0KC00-0AA0
• Rittal CP-L
Adapter set for
6AV7 674-0KB00-0AA0
• Rose GT48/2
• Rolec taraPLUS
• Rittal CP-S
• Bernstein CS3000 Coupling 48
• Rolec Quadro
• Rose GTK electronic
Adapter set for
6AV7 674-0KD00-0AA0
• VESA 100
• Rose GTN II
Adapter set for
6AV7 674-0KE00-0AA0
• VESA 75
8
Siemens ST 80 · 2009
8/7
© Siemens AG 2008
Fully enclosed HMI units
Accessories for Fully enclosed HMI units
8
■
8/8
Siemens ST 80 · 2009
© Siemens AG 2008
Appendix
9/2
9/4
Training
Standards and approbations
9/5
9/6
9/6
9/7
Siemens contacts worldwide
Partners
WinCC Competence Center
Siemens Solution Partner
Automation, Power Distribution
and PLM
9/8
9/8
Online Services
Information and ordering in the
Internet and on CD-ROM
9/9
9/9
9/10
9/10
9/11
Customer Support
Our services for every phase
of your project
Knowledge Base on CD-Rom
Automation Value Card
Software licenses
9/12
Subject index
9/15
Order No. index
9/17
Suggestions for improving
the catalog
9/18
Conditions of sale and delivery
Export regulations
Siemens ST 80 · 2009
© Siemens AG 2008
Appendix
Training
■ Faster and more applicable know-how:
Hands-on training from the manufacturer
SITRAIN® – the Siemens Training for Automation and Industrial
Solutions – provides you with comprehensive support in solving
your tasks.
Training by the market leader in automation and plant engineering enables you to make independent decisions with confidence. Especially where the optimum and efficient use of products and plants are concerned. You can eliminate deficiencies in
existing plants, and exclude expensive faulty planning right from
the beginning.
■ SITRAIN highlights
Top trainers
Our trainers are skilled teachers with direct practical experience.
Course developers have close contact with product development, and directly pass on their knowledge to the trainers.
Practical experience
The practical experience of our trainers enables them to teach
theory effectively. But since theory can be pretty drab, we attach
great importance to practical exercises which can comprise up
to half of of the course time. You can therefore immediately implement your new knowledge in practice. We train you on stateof-the-art methodically/didactically designed training equipment. This training approach will give you all the confidence you
need.
Wide variety
With a total of about 300 local attendance courses, we train the
complete range of Siemens products as well as interaction of the
products in systems. Telecourses, teach-yourself software and
seminars with a presenter on the Web supplement our classic
range of courses.
Tailor-made training
We are only a short distance away. You can find us at more than
50 locations in Germany, and in 62 countries worldwide. You
wish to have individual training instead of one of our
300 courses? Our solution: We will provide a program tailored
exactly to your personal requirements. Training can be carried
out in our Training Centers or at your company.
First-class know-how directly pays for itself: In shorter startup
times, high-quality end products, faster troubleshooting and
reduced downtimes. In other words, increased profits and lower
costs.
Achieve more with SITRAIN
• Shorter times for startup, maintenance and servicing
• Optimized production operations
• Reliable configuration and startup
• Minimization of plant downtimes
• Flexible plant adaptation to market requirements
• Compliance with quality standards in production
• Increased employee satisfaction and motivation
• Shorter familiarization times following changes in technology
and staff
9
■ contakt
Visit our site on the Internet at:
www.siemens.com/sitrain
or let us advise you personally. You can request our latest
training catalog from:
SITRAIN Customer Support Germany:
Phone: +49 (0)1805 / 23 56 11
Fax:
+49 (0)1805 / 23 56 12
(0.14 €/min. from a German landline network,
mobile telephone prices may vary)
E-Mail: [email protected]
9/2
Siemens ST 80 · 2009
The right mixture: Blended learning
"Blended learning" means a combination of various training media and sequences. For example, a local attendance course in
a Training Center can be optimally supplemented by a teachyourself program as preparation or follow-up. Additional effect:
Reduced traveling costs and periods of absence.
© Siemens AG 2008
Appendix
Training
■ Training offer for SIMATIC HMI
This page contains an overview of the SIMATIC HMI training
courses.
Depending on your demands we’ll make you fit for specific
applications or teach you important background knowledge
about products and systems.
All courses contain the largest possible share of practical exercises so that training can be carried out very intensively in very
small groups.
Further information regarding course contents, dates and prices
can be found in the Internet under:
www.siemens.de/sitrain
■ SITRAIN courses for SIMATIC HMI
Decision makers, sales personnel
Project managers, project assistants
Programmers
Startup engineers, configuration engineers
Service personnel
Operators, users
Maintenance personnel
Title
Target Group
Duration/
Medium
Short title
ST-BPROPRS
SIMATIC ProTool/Pro
SIMATIC ProTool/Pro system course
✔
✔
✔
✔
✔
3 days
SIMATIC ProTool/Pro
✔
✔
✔
✔
✔
CD-ROM
SM-PROTOO
SIMATIC ProTool/Pro
✔
✔
✔
✔
✔
WBT
WT-PROTOO
✔
✔
3 days
ST-WCCFSYS1
1 day
ST-WCCFO
9
SIMATIC WinCC flexible
SIMATIC WinCC flexible, system course 1
✔
✔
✔
SIMATIC WinCC flexible options
✔
✔
✔
SIMATIC WinCC flexible
✔
✔
✔
✔
✔
WBT
WT-WCCFLEX
SIMATIC WinCC V6, system course
✔
✔
✔
✔
✔
5 days
ST-BWINCCS
SIMATIC WinCC V6, options, network, data base
✔
✔
5 days
ST-BWINOND
ANSI-C in the SIMATIC World, Introduction
✔
✔
✔
✔
5 days
ST-SIMACE
Visual Basic Script in the field of SIMATIC
✔
✔
✔
✔
3 days
ST-VBSCR
SIMATIC WinCC
Siemens ST 80 · 2009
9/3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement