General Catalog 2013-2014
2014
Electrical Measuring Instruments
General Catalog
Recorders
Data loggers
Power Meters
LCR Testers
Battery Testers
Current Probes
Clamp Sensors
Recorders / Data Loggers / Remote Measurement System / Component Measuring Instruments / Signal Sources / Safety Standards Measuring Instruments
/ Power Measuring Instruments / Clamp on Sensors / Measurement in Telecommunications / Environmental Measuring Instruments / Digital Multi Meters /
Insulation and Earth Testers / Clamp Meters / Meter Relays / Automatic Testing Equipment
Electrical Measuring Instruments
from Shinshu Ueda
This year, HIOKI is celebrating the 78th anniversary of its founding in 1935. Going forward,
we remain committed to developing professional tools for electrical measurement
that deliver the solutions customers need. All development, production, sales, and
service departments are based at our Head Office and Plant in the lush region of
Shinshu Ueda. By keeping the full range of development and production work
in-house, we are able to meet customer needs with unparalleled speed.
SOLUTION FACTORY
With all operations centralized at our Solution Factory, we can deliver high-quality
products to customers.
Sales
Design
Call Center
Realizing customers'
wishes through
solutions-based sales
Development
Development
Board design
Nagano
Repair and calibration
Delivering high added
value through proprietary
technologies
Production
Leveraging HIOKI's
production system to
provide high-quality, lowcost products quickly
Shipment
Vacuum deposition
Board population
In-house printing
Assembly
Major New Products
P.39
P.37
P.60
RESISTANCE METER RM3545
C METER 3506-10
POWER METER PW3336, PW3337
Measure resistance with a 6.5-digit,
1,200,000-count display at a maximum resolution of 0.01 μΩ to cover a wide range of components including inverter motor windings.
1 MHz source frequency, high-precision
and ultra high speed measuring of very low
capacitance. Improved noise resistance and
enhanced repeatability in measurement precision ideal for production lines.
Accurately measure up to 1,000 V, 65 A AC/
DC with direct input. Measure large currents
up to 5000 A AC when used with a flexible
clamp sensor.
P.79
P.79
P.25
DIGITAL MULTIMETER DT4250 Series
DIGITAL MULTIMETER DT4220 Series
WIRELESS LOGGING STATION LR8410-20
Display of multiple measurement parameters
for speedy measurement.
CAT IV 600 / CAT III 1000 design for maximum
safety.
Compact design for maximum portability.
Test leads conveniently wrap around the back.
All models are CATIV 300V / CATIII 600V compliant, providing a high level of safety.
Download data using Bluetooth® wireless
technology.
One LR8410-20 can control up to seven measurement modules, allowing it to gather up to
105 channels of data.
P.40
P.39
P.57
RESISTANCE METER RM3544
RESISTANCE METER RM3548
CLAMP ON POWER LOGGER PW3360-20/-21
High-precision bench-top resistance meter
for both manual operation and integration with
automatic lines. High-precision specs in a
compact package measure from 0.000 mΩ (at
300 mA) to 3.5 MΩ.
Easily record up to 1000 data points in memory
simply by applying the instrument's probes.
Portable design is ideal for maintenance and
testing of large equipment.
Supports single-phase lines to 400 V threephase/four-wire lines. Store months of data on
SD cards. The Quick Set navigation system
helps prevent measurement mistakes.
P.78
P.83
P.83
DIGITAL MULTIMETER DT4281, DT4282
INSULATION TESTER IR4057-20
INSULATION TESTER IR4056-20
Two models provide high accuracy and fast
response. 60,000 count, 5-digit display of high
resolution measurements.
With a stable value display, high-speed measurement, and bar-graph functionality, the
IR4057-20 can replace similar analog instruments.
5-range testing voltage 50 V/100 MΩ to 1000
V/4000 MΩ. Stable & high-speed digital reading, 0.8 second response time of PASS/FAIL
decisions, and integrated rigid case.
New Product Information
Break New Ground with HIOKI Measurement Technologies
HIOKI's Philosophy
"Respect for Humanity" and "Contribution to Society".
To develop as a company, it is essential not only to create an
environment in which every employee can make the most of
his or her skills, but also to act as a good corporate citizen.
Giving shape to this philosophy constitutes HIOKI’s corporate
social responsibility, and this philosophy serves as the backbone for everything we do.
Providing High-quality Products and the Best Possible Service
Electrical measuring instruments, known as the "mother tools" of industry,
play an essential support role in the development of technology. HIOKI is com-
Corporate History
2011
HIOKI's community service programs are recognized with the Special
Prize at the City of Ueda's Excellence Awards.
provide high-quality products and the best possible service.
2009
HIOKI's main factory is recognized by the Prime Minister of Japan for
distinguished service in promoting afforestation.
In addition to contributing to social good through the development, manufacture, and sale of electrical measuring instruments, HIOKI will actively support
2007
HIOKI volunteers plant 1,300 seedlings in Kenya to support the Kenya
Vegetation Restoration Project.
mitted to contributing to the development of all industries by continuing to
afforestation programs as well as activities that aim to promote the development of culture and education in local communities. This focus reflects our
awareness that we, too, are part of the communities in which we conduct our
business activities. One such initiative is the Local Afforestation program, an
effort to "greenify" the local community.
n Local Afforestation program
In 1995, HIOKI began supporting tree-planting efforts at local schools and
public facilities as a way to work with local residents to create a rich, verdant
environment. Since September 2005, this afforestation program has been
overseen by the HIOKI Scholarship and Greening Foundation. (In March 2013,
the organication became a public utility foundation.)
2005
The HIOKI Scholarship and Greening Foundation is established.
HIOKI receives the Minister of Economy, Trade and Industry Award in
recognition of its active promotion of afforestation.
2003
HIOKI is listed on Section 1 of the Tokyo Stock Exchange.
1995
HIOKI launches the Local Afforestation program.
HIOKI receives the Green City Award/Afforestation Encouragement
Prize.
1994
HIOKI launches high-frequency band current probes for use with oscilloscopes.
1990
The Head Office and main factory are relocated to a newly completed
facility at HIOKI Forest Hills in Ueda, Nagano Prefecture.
HIOKI launches the X-Y IN-CIRCUIT HiTESTER 1110.
1987
HIOKI enters the electronic component measuring instrument market
by launching the LCR HiTESTER 3520.
1986
HIOKI enters the printed circuit board testing system market by launching the IN-CIRCUIT HiTESTER 1101, a board testing sytem.
1983
HIOKI launches the MEMORY HiCORDER 8801, becoming the first company in the industry to bring to market an instrument that records data
both on thermal paper and in built-in memory.
HIOKI's CLAMP-ON POWER HiTESTER receives the Excellent Product
Award and the Excellent Energy-saving Product Award.
1978
HIOKI launches the industry-leading CLAMP-ON POWER HiTESTER 3131.
1952
The U.S. Air Force (Far East) contracts HIOKI to manufacture MIL-SPEC
multi-testers for use in aircract maintenance.
HIOKI receives an order for a large number of TS-352A/u multitesters for
use with aircraft.
1945
HIOKI's plant is relocated to Sakaki-machi in Nagano.
1935
HIOKI starts manufacturing electrical indicating meters in Minato-ku,
Tokyo.
Contents
P.2 - 3
Category Index.......................... P.4 - 15
LCR meters, Resistance meters, Battery testers,
Super meg-ohm testers, DMM, Calibrator
................................................. P.32 Leakage current testers, Insulation
withstanding testers, Protective ground tester
................................................. P.51 Power meters, Power quality analyzers
.................................................. P.56AC/DC Current sensors, Current probes
.................................................. P.64LED optical meter, Optical power meters,
LAN cable testers, Noise loggers
................................................. P.69 Magnetic field tester, Temperature tester,
Sound level / Lux / Rotation testers
................................................... P.72DMM, Testers............................... P.76 Insulation testers, Clamp meters, Earth testers,
Voltage detectors, Phase detectors....... P.83CT, Shunts, Meter Relays
................................................. P.95 -
Recorders LCR / Resistance
Optical &
Environmental DMM/Testers Meter Relays
Safety Testing Power Meters Current Sensors Telecommunication
Data Loggers
Measuring
Field Measuring Other Testing Equipments
Meters
Memory recorders, Data loggers
.................................................. P.16 -
Index
About the Catalog........................
Other
n Model Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.97 - 101
n HIOKI Product Warranties . . . . . . . . . . . . . . . . . . . . . . . P.102
n HIOKI's Calibration System . . . . . . . . . . . . . . . . . . . . . . P.103
1
About the Catalog
l This catalog is organized by product group
Search for products using the field-based (category-based)
index on the first page. Products have been grouped using
general names by principal application.
11 About the marks
l A list of all available products can be found
at the end of the catalog
The list is organized by product model and encompasses all
products and pricing, including options.
l Options
Individual product pages include dedicated options. Options
t hat a re u sed by ent i re product g roups a re i nt roduced
together under the corresponding product group. For option
specifications and other detailed information, please see the
catalog for the product in question.
l Dimensions and mass
Exterior dimensions exclude protrusions, and are given in
order of width(W), height(H), and depth(D), in mm units.
Indicated weight represents an approximation of the mass of
the main unit only, not including case, accessories, etc.
Products that were released within 1 year
from the publication date of this catalog
ISO 14001/ISO 9001 certified
ISO14001
CERTIFICATE No. JQA-E-90091
Products labeled as having a three-year
warranty are covered for a period of three
years from the date of purchase (or if the date
of purchase is unknown, a period of three
years from the date of manufacture)
HIOKI is certified under the international
standard ISO 14001 for environ mental
management systems.
Supported interfaces
ISO9001
CERTIFICATE No. JMI-0216
HIOKI's product design and development,
manufacturing and sales and ser vice
operations, including repair, inspection and
calibration, with regards to our recording
devices, component measuring instruments,
signal generators, data loggers, environmental
measu r ing inst r u ments, safet y measu r ing
instr uments, clamp sensors, power meters,
field measuring instruments, as well as their
integrated modules and options, are certified by
the international standard ISO 9001 for quality
management and quality assurance. (Remote
measuring systems are excluded.)
True RMS measuring capability for accurate
measurement of even distorted waveforms.
l Battery labeling
Battery labeling complies with IEC international standards
and includes R6P (AA), R03 (AAA), 6F22 (9 V), LR6 (AA
alkaline), LR03 (AAA alkaline), and CR2032 (button-cell
lithium).
12 Measurement categories (Overvoltage categories)
To ensure safe operation of measurement products, IEC 61010 establishes safety standards for various electrical environments, categorized as CAT II to
CAT IV *1, and called measurement categories. These are defined as follows.
CAT II : Primary electrical circuits in equipment connected to an AC electrical outlet by a power cord (portable tools, household appliances, etc.)
CAT III : P
rimary electrical circuits of heavy equipment (fixed installations) connected directly to the distribution panel, and feeders from the distribution
panel to outlets.
CAT IV : The circuit from the service drop to the service entrance, and to the power meter and primary overcurrent protection device (distribution panel).
*1: CAT I
was eliminated from the IEC 61010 : 2010 edition
How to view categories
CAT III
300 V
Measurement category appropriate
for location of use
Voltage to earth
l 3-phase 3-wire (3φ3W) : 400V
About the indicated voltage
Black: Input-to-ground voltage
(Including line voltage)
Red: Line voltage
Higher-numbered categories correspond to electrical environments with greater
momentary energy, so a measurement product designed for CAT III environments can
endure greater momentary energy than one designed for CAT II .
*HIOKI products bearing the CE Mark are designed in accordance with the requirements for
the relevant measurement categories. To ensure safe use of measuring instruments, please
use products displaying the appropriate CAT label for the intended location of use.
Although the line voltage for the 400 V line shown in the figure is
415 V, the input-to-ground voltage is 240 V (300 V) or less.
Introducing compliance with the revised IEC 61010-031*2 handheld probe safety standard ! Test leads with caps to prevent short-circuits
Without cap: Danger
of short circuits
Danger of short-circuit between copper bar and probe
Old
With cap: Avoid
*2 IEC 6101-031 international safety standard for probes
The following additional requirements have been added to augment past safety requirements:
l To prevent short-circuits caused by the test lead probe tip, probes used in CAT III and CAT IV
applications must have 4 mm or less exposed metal (before: 19 mm or less).
l Users must be able to recognize cable wear based on colors by means of two-layer insulation
(past: single-layer insulation).
short circuits
Removable to allow use in older applications
Without cap, probe qualifies as CAT II
New
2
L9207-10 tip
To prevent short-circuit accidents,always use the probe with the cap
attached in CAT III and CAT IV measurement applications.
Remove the cap when using the probe in a CAT I or CAT II application.
About the Catalog
13 Standards and Precautions
CE marked
The CE mark certifies that a product complies with
electrical safety standards established by European
Community directives (EC directives). These EC
directives require conformance of a product to EN/IEC
standards for electrical safety.
•HIOKI's products bearing the CE Mark are designed
to confirm to the Low Voltage and EMC directives
based on the EC directives.
•The Low Voltage directive is applicable to products
operating from 50 to 1000V AC and 75 to 1500V DC,
and require protection from electrical hazards such as
electric shock.
•The EMC directive requires suppression of emissions
of harmful electromagnetic radiation, and the ability
to withstand exposure to external electromagnetic
radiation without malfunction.
WARNING
In some cases, power lines may carry voltage spikes of
several times the normal supply voltage. For reasons of safety,
ordinary testers should not be used to measure power lines
carrying more than 250V. When measuring such power lines,
always use a tester with built-in overcurrent protection to
guard against short circuits, such as Model 3008 and CAT III
marked products.
Note : An industrial power line refers to a high-capacity supply circuit to equipment in factories or
offices. A high-capacity supply circuit refers generally to a line carrying 20 A or more. This does not
therefore include supply lines protected by overcurrent protection (fuses) or distribution breakers.
WARNING
1. To avoid short circuits and electric shock accidents when
using a clamp-on sensor, use only with power lines carrying
voltages within the rating limit of the sensor.
2. Products shown with this icon may only be used with
insulated conductors (wires or cables that are covered with a
proven insulation material.)
14 Rectification Methods: True RMS and Mean
There are two methods for converting current into RMS values: the true RMS method (true RMS value indication) and the mean method (mean rectification RMS
value indication). Although both methods yield the same value for undistorted sine waves, distortion of the waveform causes the values to diverge.
True RMS
RMS value method (true RMS value indication)
n Comparing distorted current
values from an inverter, etc.
The waveform including harmonic components is calculated according to an
RMS calculation formula and displayed.
MEAN
Mean-type clamp ammeter
Mean method (mean rectification RMS value indication)
The input waveform is treated as an undistorted sine wave (single frequency only). The AC signal
mean is calculated, converted to an RMS value, and displayed. The measurement error increases when
the waveform is distorted.
*Widespread use of equipment such as inverter devices and switching power supplies has made it
more common for current waveforms being measured to be distorted. It is recommended to use a
measuring instrument that uses the true RMS method to ensure accurate measurement.
Current waveform from an
inverter (primary side)
True RMS clamp ammeter
15 Accuracy and tolerances
l f.s. (maximum display, or length of scale, ... full-scale)
Signifies the maximum display (scale) value or
the length of the scale (in cases where the scale
consists of unequal increments or where the
maximum value cannot be defined). In general,
this is the range value (the value written on
the range selector, or equivalent) currently in
use. However, be aware that in cases where the
maximum display value is 2000V but the range
value is only 600V, the maximum display value
(scale value) is still used as the f.s. value.
l rdg. (displayed or indicated value, ... reading value)
This signifies the value actually being measured,
i.e., the value that is currently indicated or
displayed by the measuring instrument.
Measuring 100 V using the 300 V
range
300V range
l dgt. (digital resolution, ... digit)
Signifies the smallest display unit on a digital
measuring instrument, i.e., the value displayed when
the last digit on the digital display is "1". Essentially,
this indicates an error of 1 digit (based on decimal
processing in analog-to-digital conversion), but in
actuality this is the digit error combined with the
f.s. error converted to a fraction of a digit unit. The
accuracy associated with a particular measured
value as shown in the product specifications is
derived from these values.
In the 300 V range, the 0.1 V digit is the smallest digit
Example accuracy calculations
[Example accuracy calculation 1] (when the accuracy notation combines rdg. and dgt.)
[Example accuracy calculation 2] (when the accuracy notation combines rdg. and f.s.)
Accuracy specification: ±1.0% rdg. ±3 dgt.
Measurement range:
300.0 V
Measured value:
100.0 V
Accuracy specification: ±0.2% rdg. ±0.1% f.s.
Measurement range:
300.00 V
Measured value:
100.00 V
Since the value being measured is 100.0 V:
(A) Reading error (±% rdg.): ±1.0% of 100.0 V = ±1.0 V
(B) Digit error (dgt.): Since the maximum resolution is 0.1 V, ±3 dgt. = ±0.3 V
(C) Total error (A+B): ±1.3 V
Based on the total error (C), the error boundary values for a measured value of
100.0 V would be 98.7 V to 101.3 V.
Since the value being measured is 100.00 V:
(A) Reading error (±% rdg.): ±0.2% of 100.00 V = ±0.20 V
(B) Full-scale error (±% f.s.): ±0.1% of 300 V = ±0.30 V
(C) Total error (A+B): ±0.50 V
Based on the total error (C), the error boundary values for a measured value of
100.00 V would be 99.50 V and 100.50 V.
This Electrical Measuring Instruments General Catalog provides a product outline. For more detailed information, please refer to individual product catalogs
and series catalogs, which group together similar products.
3
Recorder Index
Portable Memory Recorders for
Servicing and Maintenance
Simultaneously Capture Multiple
Signals at High Speeds
Index
MEMORY HiCORDER
Monitor Anomalies in the Power Line
MR8847-01 (64MW) 16ch
MR8847-02 (256MW) 16ch
MR8847-03 (512MW) 16ch
20MS/sec
(50ns)
10MS/sec
MEMORY HiCORDER
8870-20 (2ch)
(100ns)
Instantaneous waveform/
RMS value waveform
recording, FFT analysis,
Waveform judgement
. . . . . . . . . . . . . . . . p.18
MEMORY HiCORDER
MR8880-20 (4ch)
1MS/sec
Instantaneous waveform
observation
. . . . . . . . . . . . . . . . p.17
(1μs)
400kS
100kS/
sec
Instantaneous waveform/
RMS value waveform
recording
. . . . . . . . . . . . . . . . p.16
Sampling speed
(10μs)
10kS/sec
(100μs)
Log Multiple Channels of MICRO HiCORDER
8205-10 (1ch)
1kS/sec
(1ms)
Discontinued
MICRO HiCORDER
8206-10 (2ch)
MEMORY HiLOGGER
LR8431-20 (10ch)
Discontinue
scheduled
AC/DC measurement
For power line fault monitoring
. . . . . . . . . . . . . . p.19
. . . . . . . . . . . . . . p.19
PEN RECORDER
PEN RECORDER
PR8111 (1ch)
PR8112 (2ch)
100S/sec
(10ms)
DC/Temperature/Pulse
measurement
. . . . . . . . . . . . . . . . p.24
10S/sec
(100ms)
1S/sec
DC measurement,
150 mm chart width
. . . . . . . . . . . . p.20
DC measurement,
150 mm chart width
. . . . . . . . . . . . p.20
Data loggers
LR 5000s
(1sec)
Multi-signal recording
. . . . . . . . . . . . . . p.28
0.1S/sec
(10sec)
1ch
2ch
4ch
Number of channels
Memory Recorder Options
PC Software for Data Management
MEMORY HiVIEWER
9725
• CAN ADAPTER 8910
Record and Analyze
CAN-Bus Signals
• DIFFERENTIAL PROBE
9322
Floating measurement of
high- voltage waveforms
. . . . . . . . . . . . . . . p.21
4
• Connection cord
• PC card
• Logic probe
• Clamp on probe, etc
. . . . . . . . . . . . . . . . p.22
WAVE PROCESSOR
9335
• Functions identical to those • Convert data, print and
of the Memory HiCorder
display waveforms
8860 Series
. . . . . . . . . . . . . . . . p.20
. . . . . . . . . . . . . . . . p.20
LAN COMMUNICATOR
9333
• For LAN communication
with the Memory HiCorder
8826
• For data collection and
remote control
. . . . . . . . . . . . . . . . p.20
8ch
10ch 16ch
Recorder Index
Multi-Channel Recorders
MEMORY HiCORDER
MR8741 (16ch)
MEMORY HiCORDER MEMORY HiCORDER
8861-50 (32ch)
MR8740 (54ch)
Instantaneous waveform/
RMS value waveform
recording, FFT analysis
. . . . . . . . . . . . . . . . p.17
Systems Integration
. . . . . . . . . . . . . . . . p.19
Instantaneous waveform/
RMS value waveform
recording, FFT analysis
. . . . . . . . . . . . . . . . p.17
Index
MEMORY HiCORDER
8860-50 (16ch)
Ideal for rack-mounting
. . . . . . . . . . . . . . . . p.19
MEMORY HiCORDER
8826 (32ch)
MEMORY HiCORDER
MR8875 (16ch)
Instantaneous waveform/
RMS value waveform
recording, FFT analysis
. . . . . . . . . . . . . . . . p.18
Instantaneous waveform/
Temperature/Pulse/CAN
signal measurement
. . . . . . . . . . . . . . . . p.16
Temperature, Voltage and More
MEMORY HiLOGGER
8423 (120ch)
MEMORY HiLOGGER
LR8400-20s (30ch)
DC/Temperature/Pulse
measurement
. . . . . . . . . . . . . . p.26
WIRELESS LOGGING STATION
LR8410-20 (15ch)
DC/Temperature
measurement
. . . . . . . . . . p.25
16ch
PV POWER VERIFIER
LR8400-92/93 (30ch)
For PV measurement
. . . . . . . . . . . . . . p.27
30ch
MEMORY HiCORDER
8860-50 (64ch)
MEMORY HiLOGGER
8423 (600ch)
MEMORY HiCORDER
8861-50 (128ch)
DC/Temperature/Pulse
measurement
. . . . . . . . . . . . . . p.24
MEMORY HiLOGGER
LR8400-20s (60ch)
WIRELESS LOGGING STATION
Instantaneous/RMS value LR8410-20 (105ch)
Instantaneous/RMS value
waveform recording with
waveform recording with
scanner input support
scanner input support
. . . . . . . . . . . . . . . . p.17
. . . . . . . . . . . . . . . . p.17
DC/Temperature/Pulse
measurement
. . . . . . . . . . . . . . p.26
DC/Temperature
measurement
. . . . . . . . . . p.25
32ch
60ch
64ch
120ch
128ch
DC/Temperature/Pulse
measurement
. . . . . . . . . . . . . . p.24
....600ch
Number of channels
5
Data Logger Index
Index
Monitor Power Demand and Equipment Efficiency
CLAMP ON POWER
LOGGER PW3360-20/-21
• Designed for 50/60 Hz commercial
line use
• 3 circuits (1P2W), single circuit
(1P3W, 3P3W, 3P4W)
• Save data to the SD card continually
• Clamp input
• Harmonic analysis function
(PW3360-21)
. . . . . . . . . . . . . . . . . . p.57
Compact 1- and 2-Channel Temperature and Humidity Loggers
TEMPERATURE LOGGER HUMIDITY LOGGER
LR5011
LR5001
• 1 ch Temperature
recording
• - 40 °C to 180 °C (with
optional sensor)
• Minimum 1 sec interval
• 60000 data × 1ch memory
• Dry cell battery operation
• IP54 (splash-proof)
. . . . . . . . . . . . . . . . . . p.30
6
• 2 ch Temperature /
Humidity alternating
recording
• - 40 °C to 85 °C/ 0 to 100
%rh (with LR9504 sensor)
• Minimum 1 sec interval
• 60000 data × 2ch memory
• Dry cell battery operation
• IP54 (splash-proof)
. . . . . . . . . . . . . . . . . . p.31
Compact 2-Channel DC Voltage Loggers
Compact 2-Channel AC Current Loggers
VOLTAGE LOGGER
LR5041
VOLTAGE LOGGER
LR5042
VOLTAGE LOGGER
LR5043
CLAMP LOGGER
LR5051
• 1ch DC voltage recording
• ±50mV DC
• Minimum 1 sec interval
• 60000 data × 1ch memory
• Dry cell battery operation
• IP54 (splash-proof)
. . . . . . . . . . . . . . . . . . p.29
• 1ch DC voltage recording
• ±5V DC
• Minimum 1 sec interval
• 60000 data × 1ch memory
• Dry cell battery operation
• IP54 (splash-proof)
. . . . . . . . . . . . . . . . . . p.29
• 1ch DC voltage recording
• ±50V DC
• Minimum 1 sec interval
• 60000 data × 1ch memory
• Dry cell battery operation
• IP54 (splash-proof)
. . . . . . . . . . . . . . . . . . p.29
• 2ch AC current recording
(with optional sensor)
• 0 to 1000 A AC
• Minimum 1 sec interval
• 60000 data × 2ch memory
• Dry cell battery operation
. . . . . . . . . . . . . . . . . . p.29
Compact 1-Channel Instrumentation Loggers
Peripherals for Compact Loggers
INSTRUMENTATION
LOGGER LR5031
COMMUNICATION
ADAPTER LR5091
DATA COLLECTOR
LR5092-20
• 1 ch 0 to 20mA recording
• Minimum 1 sec interval
• 60000 data × 1ch memory
• Dry cell battery operation
• IP54 (splash-proof)
. . . . . . . . . . . . . . . . . . p.30
• Used with the LR5000
series
• Transfer setting/clock data
from PC to the LR5000s
• Free bundled software
• USB interface
. . . . . . . . . . . . . . . . . . p.28
• Used with the LR5000 series
• Collect recorded data from the
data logger to internal memory
or SD card
• View collected data in a graph
• Transfer data from a data
logger to the PC
• Free bundled software
• USB interface
. . . . . . . . . . . . . . . . . . p.28
LCR Meter / Resistance Meter / Battery Tester Index
Index
LCR Testing in Research and Development
CHEMICAL IMPEDANCE
ANALYZER IM3590
IMPEDANCE ANALYZER
IM3570
EQUIVALENT CIRCUIT
LCR HiTESTER 3535
ANALYSIS FIRMWARE IM9000
LCR METER IM3533
LCR METER IM3533-01
LCR HiTESTER 3532-50
• |Z|, L, C, R, σ (conductivity), ε (dielectric constant)
testing
• Battery measurement
• Testing source frequency:
1 mHz to 200 kHz
• Measuring time: 2 ms
. . . . . . . . . . . . . . . . . . p.32
• |Z|, L, C, R testing
• Testing source frequency:
4 Hz to 5 MHz
• Measuring time: 0.5 msec
• Measure LCR and conduct
frequency sweeps simultaneously
. . . . . . . . . . . . . . . . . . p.33
• Optional software built in to
the IM3570
• Equivalent five circuit models
• Enables displaying the ideal
frequency characteristics
graph derived from the analysis results
• Cole-Cole plot, Admittance
circle display
. . . . . . . . . . . . . . . . . . p.33
• |Z|, L, C, R testing
• Testing source frequency:
1 mHz to 200 kHz
• Measuring time: 2 ms
• Transformer measurement
mode
• Frequency sweep measurement: (IM3533-01)
. . . . . . . . . . . . . . . . . . p.34
• |Z|, L, C, R testing
• Testing source frequency: 42Hz to 5MHz
• Measuring time: 5 ms
. . . . . . . . . . . . . . . . . . p.35
• |Z|, L, C, R testing
• Testing source frequency: 100kHz to 120MHz
• Measuring time: 6 ms
. . . . . . . . . . . . . . . . . . p.35
LCR and Capacitance Testing During Component Production
LCR METER IM3523
LCR HiTESTER 3511-50
C METER 3506-10
C HiTESTER
3504-40/-50/-60
• |Z|, L, C, R testing
• Testing source frequency:
40 Hz to 200 kHz
• Measuring time: 2 ms
. . . . . . . . . . . . . . . . . . p.34
• |Z|, L, C, R testing
• Testing source frequency: 120 Hz or 1 kHz
• Measuring time: 5 ms
. . . . . . . . . . . . . . . . . . p.36
• C, D (tan δ), Q testing,
Measure low capacitance
• Testing source frequency: 1 kHz, 1 MHz
• Measuring time: 1.5 ms
(1 MHz)
• RS-232C, GP-IB
. . . . . . . . . . . . . . . . . . p.37
• C, D (tan δ) testing, Measure
high capacitance MLCC
• Testing source frequency:
120 Hz or 1 kHz
• Measuring time: 2 ms
• RS-232C standard
(3504-50) BIN function,
GP-IB
(3504-60) BIN function,
Contact check, GP-IB
. . . . . . . . . . . . . . . . . . p.37
DC Resistance Testing
RESISTANCE METER
RESISTANCE METER
RM3545, RM3545-01/-02 RM3548
Printers
RESISTANCE METER
RM3544, RM3544-01
RESISTANCE HiTESTER
RM3543, RM3543-01
RESISTANCE HiTESTER
RM3542, RM3542-01
RESISTANCE HiTESTER
3541
DIGITAL PRINTER 9203
Discontinue
scheduled
• For coil or line resistance to
high resistance measurement
• Testing source: DC, 1 A max
• Fastest measurement speed:
2.2ms
• Finest resolution: 0.01 μΩ
• Multi-point measurement: 20
locations
. . . . . . . . . . . . . . . . . . p.39
• High-precision portable
• High-precision bench-top
resistance meter measures resistance meter for both
from µΩ to MΩ
manual operation and
• Testing source current:
integration with automatic
DC, 1 A Max.
lines
• Display refresh rate:
• Testing source current:
approx. 100 ms
DC, 300 mA Max.
• Finest resolution: 0.1 μΩ • Fastest measurement
. . . . . . . . . . . . . . . . . . p.39
speed: 18 ms
• Finest resolution: 1 μΩ
. . . . . . . . . . . . . . . . . . p.40
• Advanced enough to measure 0.1 mΩ shunts with
room to spare
• Ideal high precision &
high resolution for automated lines
• Testing source: DC
• Minimum integration
time: 0.1 ms
• Finest resolution: 0.01 μΩ
. . . . . . . . . . . . . . . . . . p.41
• High speed resistance
meter ideal for automated
lines
• Testing source: DC
• Fastest measurement time:
0.9 ms
• Minimum integration
time: 0.1 ms
• Finest resolution: 0.1 μΩ
. . . . . . . . . . . . . . . . . . p.41
• For coil or line resistance
to high resistance measurement
• Testing source: DC
• Minimum response time:
a few ms
• Sampling rate: 0.6 ms ±0.3
ms
• Finest resolution: 0.1 μΩ
. . . . . . . . . . . . . . . . . . p.42
• Prints out measurement
data at fixed intervals
• For Model 3540-02, 3560,
3550, 3551, 3227
. . . . . . . . . . . . . . . . . . p.36
Probes and Test
Fixtures
Battery Testing
BATTERY HiTESTER
BT3563, BT3563-01
BATTERY HiTESTER
BT3562, BT3562-01
BATTERY HiTESTER
3561, 3561-01
BATTERY HiTESTER
3555
BATTERY HiTESTER
3554
• The perfect battery tester
for production lines
• Testing source AC 1kHz
• Measure of High-voltage
Battery Packs up to 300V
• Measurement time: 18ms
• Finest resolution 0.1µΩ
and 10µV
. . . . . . . . . . . . . . . . . . p.43
• The perfect battery tester
for production lines
• Testing source AC 1kHz
• Measure of High-voltage
Battery Packs up to 60V
• Measurement time: 18ms
• Finest resolution 0.1µΩ
and 10µV
. . . . . . . . . . . . . . . . . . p.43
• The perfect battery tester
for small secondary batteries
• Testing source AC 1kHz
• Measurement time: 10ms
• Finest resolution 0.01mΩ
. . . . . . . . . . . . . . . . . . p.43
• For compact secondary
batteries: check battery
deterioration
• Testing source AC 1kHz
• Finest resolution 100µΩ
. . . . . . . . . . . . . . . . . . p.44
• For compact secondary
batteries up to large lead
batteries; to check battery
deterioration
• Testing source AC 1kHz
• Finest resolution 1µΩ
. . . . . . . . . . . . . . . . . . p.44
• Probes and test fixtures
for lead components
• Test fixtures for SMDs
• DUT size table
. . . . . . . . . . . . . . . . . . p.38
7
Super Megohm / DMM / Signal Generator Index
Index
Super Insulation Testing of Capacitors
SUPER MΩ HiTESTER
SM7810, SM7810-20
POWER SOURCE UNIT
SM7860 series
DIGITAL SUPER
DIGITAL SUPER
SUPER MEGOHMMETER
MEGOHMMETER DSM-8104 MEGOHMMETER DSM-8542 SM-8213, 8215, 8220
• For testing leakage current in the (MLCC)
• 6.8ms measurement speed
over 8ch simultaneously
• Testing current is applied
externally
• Resistance measurement
Max. 1×1015 Ω
• Current measurement 1pA
to 1mA
. . . . . . . . . . . . . . . . . . p.45
• A specially designed
power source unit for the
SM7810
• Supports multi-channel
systems and provides
functions required for the
MLCC test line
• 50 mA per channel output
. . . . . . . . . . . . . . . . . . p.45
• Testing voltage: 0.1V to
1,000V DC
• Resistance measurement
Max. 3×1016 Ω
• Current measurement
0.1fA to 100μA
. . . . . . . . . . . . . . . . . . p.46
• Combination use with
specially designed power
source unit PSU-8541 for
high-speed measurement
• Resistance measurement
Max. 3×1016 Ω
• Current measurement
0.1fA to 100μA
. . . . . . . . . . . . . . . . . . p.46
• Digital display
• Timer, Comparator functions
• Resistance measurement
Max. 2×1016 MΩ
• Testing voltage: 5V to
1000V DC
. . . . . . . . . . . . . . . . . . p.47
Peripherals
SURFACE/VOLUME RESISTANCE
MEASUREMENT ELECTRODE SM9001
Testing terminals for super megohm
measurement
• Simple and Convenient
Surface/Volume
Resistance Measurement
(up to 1013 Ω, 1000V)
• Surface and volume resistance of sheets and films
can be measured just as
they are without the need
to cut samples
. . . . . . . . . . . . . . . . . . p.48
• For chip capacitor testing
• For flat plate testing
• For surface resistance
testing
• For liquid testing
• A screen box
• Comparing resistance box
. . . . . . . . . . . . . . . . . . p.48
Systems Integrated Digital Multi-Module Stations
Benchtop Multimeters for Production and Inspection Lines
MEMORY HiCORDER MR8741
+ DVM UNIT MR8990
DIGITAL HiTESTER
3239, 3239-01
DIGITAL HiTESTER
3238, 3238-01
DIGITAL HiTESTER
3237, 3237-01
• Store entire data from 16 units
of DMM in a single operation
• Simultaneous 16 ch sampling
without signal scanner
• High ±0.01% precision & ultra
high 6-1/2 digit resolution
• 500 times/s sampling
. . . . . . . . . . . . . . . . . . p.50
• 4-terminal method resistance measurement
• Multi functional/high precision 5-1/2 digits
• 300 times/s sampling
• Comparator
• External control I/O
• RS-232C (-01 model:
GP-IB)
• True RMS
. . . . . . . . . . . . . . . . . . p.49
• Multi functional/high precision 5-1/2 digits
• 300 times/s sampling
• Comparator
• External control I/O
• RS-232C (-01 model:
GP-IB)
• True RMS
. . . . . . . . . . . . . . . . . . p.49
• Simple & low cost model
• High precision 5-1/2 digits
• 300 times/s sampling
• Comparator
• External control I/O
• RS-232C (-01 model:
GP-IB)
• True RMS
. . . . . . . . . . . . . . . . . . p.49
Signal Generators and Calibrators
DC SIGNAL SOURCE
SS7012
• DC constant voltage, constant
current source
• ±25 V, ±25 mA
• Thermoelectric power generation,
K, E, J, T, R,S, B, N thermocouple
• DC voltage, DC current
measurement
• Battery operation
. . . . . . . . . . . . . . . . . . p.50
8
Safety Standards Measuring Instruments Index
Index
Leakage Current Testing in Equipment and Medical Devices
LEAK CURRENT
HiTESTER ST5540
LEAK CURRENT
HiTESTER ST5541
• Both medical- and general-use
electrical devices
• Built-in support for all
networks
• Support for rated currents of
up to 20 A
• Support for automatic testing
on production lines, etc.
. . . . . . . . . . . . . . . . . . p.51
• Testing of general-use
electrical devices
• Built-in support for networks
other than medical-use
electrical devices
• Support for rated currents of
up to 20 A
• Support for automatic testing
on production lines, etc.
. . . . . . . . . . . . . . . . . . p.51
Insulation Resistance and Withstand Voltage Testing
AC AUTOMATIC INSULATION/
AUTOMATIC INSULATION/
INSULATION/ WITHSTANDING
WITHSTANDING HiTESTER 3174 WITHSTANDING HiTESTER 3153 HiTESTER 3159-02
HIGH VOLTAGE SCANNER
3930
• Insulation resistance test:
up to 2000 MΩ
• Withstanding voltage
test: up to 5 kV AC
• Contact check
• Full remote control
. . . . . . . . . . . . . . . . . . p.53
• Remote control available
• For automatic multipoint
testing of insulation /
withstand voltage
• By using the 3153's program, but also by generalpurpose logic sequencers
. . . . . . . . . . . . . . . . . . p.52
• Insulation resistance test:
up to 9999 MΩ
• Withstanding voltage
test: up to 5 kV AC/DC
• Full remote control
. . . . . . . . . . . . . . . . . . p.53
• Insulation resistance test:
up to 2000 MΩ
• Withstanding voltage
test: up to 5 kV AC
• RS-232C
• Manual voltage setting
. . . . . . . . . . . . . . . . . . p.54
PC Applications
SAFETY TEST DATA MANAGEMENT
SOFTWARE 9267
• PC-controlled application
software
. . . . . . . . . . . . . . . . . . p.52
Insulation Resistance and Withstand
Voltage Testing
AC Ground Bond Testing
DIGITAL MΩ
HiTESTER 3154
AC GROUNDING
HiTESTER 3157-01
• Testing voltage 25 to
1000V
• Insulation resistance test:
up to 4000 MΩ (at 1000V /
500V)
• Comparator / Timer function
. . . . . . . . . . . . . . . . . . p.55
• Protective ground tester
indispensable for standard
certification (low resistance measure)
• 0 to 1.8 Ω measurement
• Testing current up to 31A
. . . . . . . . . . . . . . . . . . p.55
9
Power Measuring Instruments Index
Index
Evaluate and Analyze the Power Efficiency of Motors, Equipment and other Energy Saving
Devices
POWER ANALYZER
3390-10
POWER ANALYZER
3390
POWER HiTESTER
3193-10
• High-accuracy model,
for comprehensive device
assessment
• Super precise ±0.1%
accuracy
• Wide-band DC, 0.5Hz to
150 kHz
• DC, or 1P2W to 3P4W
• 4 ch/ Clamp input
. . . . . . . . . . . . . . . . . . p.56
• For comprehensive device
assessment
• Wide-band DC, 0.5Hz to
150 kHz
• DC, or 1P2W to 3P4W
• 4 ch/ Clamp input
• Measure inverter equipment and analyze motors
. . . . . . . . . . . . . . . . . . p.56
• Analysis station for total
evaluation
• Wide-band DC, 0.5Hz to
1MHz
• DC, or 1P2W to 3P4W
• 6ch-Direct/ Clamp input
• Harmonic / Flicker measurement
. . . . . . . . . . . . . . . . . . p.63
Monitor and Record Power Quality
POWER QUALITY ANALYZER
PW3198, PW3198-90
POWER QUALITY
ANALYZER 3197
PQA-HiVIEW PRO
9624-50
• Class A Power Quality
Analyzer
• Monitor and record the
quality of power
• 1P2W to 3P4W + additional input (AC/DC 1ch)
• Clamp input
. . . . . . . . . . . . . . . . . . p.58
• Monitor and record the
quality of power
• 1P2W to 3P4W
• Clamp input
• Small-sized, lightweight
. . . . . . . . . . . . . . . . . . p.59
• For PW3198, 3197, 3196
• Easy operation, analyze
data on the PC
• Convenient report creation function
Monitor Energy Consumption and Analyze Energy Savings
Handheld Power
Tester
CLAMP ON POWER
LOGGER PW3360-20/-21
CLAMP ON POWER
HiTESTER 3169-20/-21
POWER MEASUREMENT
SUPPORT SOFTWARE 9625
POWER LOGGER
VIEWER SF1001
CLAMP ON POWER
HiTESTER 3286-20
• Designed for 50/60 Hz commercial line use
• 3 circuits (1P2W), single circuit
(1P3W, 3P3W, 3P4W)
• Save data to the SD card continually
• Clamp input
(PW3360-21) Added harmonic
analysis function
. . . . . . . . . . . . . . . . . . p.57
• Designed for 50/60 Hz commercial line use
• 4 circuits simultaneously
(1P2W) to single circuit (3P4W)
• Save demand value to the PC
card continually
• Clamp input
• Model 3169-21: D/A output
equipped
. . . . . . . . . . . . . . . . . . p.59
• Easy graphical processing
on a PC of measurement
data saved on Models
3169-20/21 and 3166
• Easy graphical processing
on a PC of measurement
data saved on Models
PW3360-20/-21
• Easy AC power checker
• Single-phase, 3-phase
(balanced load only)
• Phase angle, power factor,
harmonic levels
• True RMS
• For AC measurement
• Battery operation
. . . . . . . . . . . . . . . . . . p.89
3-Phase Power Meters for Industrial Equipment
Testing
Single-Phase Power Meters for Industrial
Equipment Testing
POWER METER PW3337, POWER METER PW3336, POWER HiTESTER
PW3337-01/-02/-03
PW3336-01/-02/-03
3331
AC/DC POWER HiTESTER POWER HiTESTER 3333
3333-01
3334, 3334-01
POWER HiTESTER
3332
Discontinued
• 3 ch input, DC, or 1P2W to
3P3W, or 3P4W
• Max. input 1000 V, 65 A
• DC, or 0.1 Hz to 100 kHz
• Basic accuracy ±0.1 %
• Direct input, LAN/RS-232C
• -01 model: GP-IB, -02
model: D/A output, -03
model: GP-IB & D/A output
. . . . . . . . . . . . . . . . . . p.60
10
• 2 ch input, DC, or 1P2W to
3P3W
• Max. input 1000 V, 65 A
• DC, or 0.1 Hz to 100 kHz
• Basic accuracy ±0.1 %
• Direct input, LAN/RS-232C
• -01 model: GP-IB, -02
model: D/A output, -03
model: GP-IB & D/A output
. . . . . . . . . . . . . . . . . . p.60
• 1P2W to 3P3W
• Max. input 600 V, 50 A
• 10 Hz to 100 kHz
• Direct input only
. . . . . . . . . . . . . . . . . . p.62
• Compliant with the
SPECpower® Benchmark
• DC, or 1P2W
• Max. input 300 V, 30 A
• DC, or 45 Hz to 5 kHz
• Basic accuracy ±0.2 %
• Guaranteed accuracy of 3
Years ±0.3 %
• Direct input only
. . . . . . . . . . . . . . . . . . p.61
• Space-saving footprint
• High accuracy ±0.2 %
• 1P2W only
• Max. input 300 V, 30 A
• 45 Hz to 5 kHz
• Guaranteed accuracy of 3
Years ±0.3 %
• Direct input only
• Model 3333-01: GP-IB
. . . . . . . . . . . . . . . . . . p.61
• Ultra-sensitive standby
power measurement
• 1P2W only
• Max. input 600 V, 50 A
• 1 Hz to 100 kHz
• Direct input only
. . . . . . . . . . . . . . . . . . p.62
Current Probes/Clamp Sensors Index
Current Probes to Observe Waveforms Using
Wide-band Power Analyzers
CLAMP ON PROBE
3276
CLAMP ON PROBE
3275
CLAMP ON PROBE
3274
CLAMP ON PROBE
3273-50
AC/DC CURRENT
SENSOR CT6865
AC/DC CURRENT
SENSOR CT6863
AC/DC CURRENT
SENSOR CT6862
• DC to 100 MHz (−3dB)
• 30 Arms maximum
• 0.1 V/A output
• φ 5 mm (0.20 in) Core dia.
. . . . . . . . . . . . . . . . . . p.64
• DC to 2MHz (−3dB)
• 500 Arms maximum
• 0.01 V/A output
• φ 20 mm (0.79 in) Core dia.
. . . . . . . . . . . . . . . . . . p.64
• DC to 10MHz (−3dB)
• 150 Arms maximum
• 0.01 V/A output
• φ 20 mm (0.79 in) Core dia.
. . . . . . . . . . . . . . . . . . p.64
• DC to 50MHz (−3dB)
• 30 Arms maximum
• 0.1 V/A output
• φ 5 mm (0.20 in) Core dia.
. . . . . . . . . . . . . . . . . . p.64
• Frequency characteristics
Amplitude: DC - 20 kHz
Phase: DC - 1 kHz
• 1000A AC/DC rated
• 2 V/1000 A output
• φ 36 mm (1.42 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.66
• Frequency characteristics
Amplitude: DC - 500 kHz
Phase: DC - 300 kHz
• 200A AC/DC rated
• 2 V/200 A output
• φ 24 mm (0.94 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.66
• Frequency characteristics
Amplitude: DC - 1 MHz
Phase: DC - 300kHz
• 50A AC/DC rated
• 2 V/50 A output
• φ 24 mm (0.94 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.66
Current Probes to Observe Waveforms Using Wide-band Power Analyzers
Power Supplies for Current
Probes
AC/DC CURRENT
SENSOR 9709
POWER SUPPLY 3272, 3269 SENSOR UNIT
9555-10
UNIVERSAL CLAMP ON CT UNIVERSAL CLAMP ON CT UNIVERSAL CLAMP ON CT CLAMP ON SENSOR
9279
9278
9277
9272-10
Index
Current Probes to Observe DC to MHz Bandwidth Waveforms on
Oscilloscopes and Memory Recorders
3272
3269
• Frequency characteristics
Amplitude: DC to 100 kHz
Phase: DC to 100 kHz
• 500A AC/DC rated
• 2 V/500 A output
• φ 36 mm (1.42 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.66
• Frequency characteristics
Amplitude: DC to 20 kHz
Phase: DC to 20 kHz
• 500A AC/DC rated
• 2 V/500 A output
• φ 40 mm (1.57 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.65
• Frequency characteristics
Amplitude: DC to 100 kHz
Phase: DC to 100 kHz
• 200A AC/DC rated
• 2 V/200 A output
• φ 20 mm (0.79 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.65
• Frequency characteristics
Amplitude: DC to 100 kHz
Phase: DC to 100 kHz
• 20A AC/DC rated
• 2 V/20 A output
• φ 20 mm (0.79 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.65
• Frequency characteristics
Amplitude: 1Hz to 100kHz
Phase: 5 Hz to 50 kHz
• 20A or 200A AC rated
• 2V/20 A, 2V/200 A output
• φ 46 mm (1.81 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.67
AC/DC Current Clamps for Commercial Power
Monitoring
Power Supplies for
Current Probes
CLAMP ON AC/DC SENSOR
CT9693-90, CT9693
CLAMP ON AC/DC SENSOR
CT9692-90, CT9692
CLAMP ON AC/DC SENSOR
CT9691-90, CT9691
SENSOR UNIT CT6590
• DC to 15 kHz (-3dB)
• 2000 A AC/DC rated input
• Output 200 mV/ f.s. via the
CT6590
• φ 55 mm (2.17 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.65
• DC to 20 kHz (-3dB)
• 200 A AC/DC rated input
• Output 200 mV/ f.s. via the
CT6590
• φ 33 mm (1.30 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.65
• Output signal for the
• DC to 10 kHz (-3dB)
• 100 A AC/DC rated input
CT9691/9692/9693 series
• Output 200 mV/ f.s. via the • Power supply for one CT659X
CT6590
sensor
• φ 35 mm (1.38 in) Core dia. • Power with LR6 batteries, AC
. . . . . . . . . . . . . . . . . . .p.65
adapter, or External DC power
. . . . . . . . . . . . . . . . . . .p.65
AC Current Clamps for Commercial Power Monitoring
CLAMP ON SENSOR
9695-02, -03
Leak Current
FLEXIBLE CLAMP ON
SENSOR CT9667
CLAMP ON SENSOR
9661
• 40 Hz to 5 kHz
• Phase: 45 Hz to 5 kHz
• 1000 A AC rated input
• 0.5 mV AC / A output
• φ 55 mm (2.17 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.68
• 10 Hz to 20 kHz (±3dB)
• 5000 A/ 500 A AC rated
input
• Output 500 mV/ f.s.
• φ 254 mm (10.0 in) Core
dia.
. . . . . . . . . . . . . . . . . . .p.68
9660:
• Frequency characteristics
• Frequency characteristics . Amplitude: 40Hz to 5kHz,
Amplitude: 40Hz to 5kHz, Phase: 45Hz to 5kHz
• 100 A AC rated input
Phase: 45Hz to 5kHz
• 1 mV AC / A output
• 500 A AC rated input
• φ 15 mm (0.59 in) Core dia.
• 1 mV AC / A output
• φ 46 mm (1.81 in) Core dia. 9694:
. . . . . . . . . . . . . . . . . . .p.68 • 5 A AC rated input
• 10 mV AC / A output
. . . . . . . . . . . . . . . . . . .p.68
9657-10
9675:
• Frequency characteristics
Amplitude: 40Hz to 5kHz
• Primary rated 10 A AC
• 100 mV AC / A output
• φ 30 mm (1.18 in) Core dia.
9657-10:
• φ 40 mm (1.57 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.68
CLAMP ON SENSOR
CT6500
CLAMP ON SENSOR
9668
CLAMP ON SENSOR
9651
CLAMP ON SENSOR
9650
CLAMP ON PROBE
9132-50, 9010-50
CLAMP ON PROBE
9018-50
• Frequency characteristics
40 Hz to 1 kHz
• Primary: 500 A AC
• Secondary: 1mV AC / A
• Max. input: 600 A AC
• φ 46 mm (1.81 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.29
• Frequency characteristics
40 Hz to 1 kHz
• Primary: 1000 A AC
• Secondary: 1000 mA AC
• Max. input: 1000 A AC
• φ 55 mm (2.17 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.68
• Frequency characteristics
40 Hz to 1 kHz
• Primary: 500 A AC
• Secondary: 500 mA AC
• Max. input: 600 A AC
• φ 46 mm (1.81 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.68
• Frequency characteristics
40 Hz to 1 kHz
• Primary: 100 A AC
• Secondary: 100 mA AC
• Max. input: 130 A AC
• φ 15 mm (0.59 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.68
• Use for level measurement
• Frequency characteristics: 40
Hz to 1 kHz
• Measurement range:
9132-50: 20 to 1000 A AC, φ 55
mm (2.17 in) Core dia.
9010-50: 10 to 500 A AC, φ 46
mm (1.81 in) Core dia.
• Output: 0.2 V AC / range
. . . . . . . . . . . . . . . . . . .p.67
• Good phase characteristics
• Frequency characteristics
Amplitude: 40 Hz to 3 kHz
Phase: 40 Hz to 3 kHz
• Measurement range: 10 to
500 A AC
• Output: 0.2 V AC / range
• φ 46 mm (1.81 in) Core dia.
. . . . . . . . . . . . . . . . . . .p.67
9695-02 Requires the 9219
• 40 Hz to 5 kHz
• Phase: 45 Hz to 5 kHz
• 50 A AC rated input
• 10 mV AC / A output
• φ 15 mm (0.59 in) Core dia.
9695-03 Requires the 9219
• 100 A AC rated input
• 1 mV AC / A output
. . . . . . . . . . . . . . . . . . .p.68
CLAMP ON SENSOR
9669
3269: Connect up to four
• Power supply for the 9270
sensors
3272: Single sensor connect- series, 9709, CT6860 series,
single sensor connectable
able
. . . . . . . . . . . . . . . . . . p.64 . . . . . . . . . . . . . . . . . . .p.65
CLAMP ON SENSOR
9660, 9694
CLAMP ON LEAK
SENSOR 9675, 9657-10
Load Current
11
Telecommunications/Environmental Measuring Instruments Index
Index
LED and Optical Power Testing for
Production Lines
Optical Power Testing for
Electrical Construction
LED OPTICAL METER
TM6101
LAN CABLE HiTESTER
3665-20
OPTICAL POWER METER
3664
New sensors
9743
9743-01
• Measure the optical characteristics of white LEDs
and LED lighting during
production.
• Measure the optical characteristics of white LEDs
with ultra high accuracy
and high speed
. . . . . . . . . . . . . . . . . . p.69
• Measure the LD light of
optical disks
• 4 -1/2 digit, 0.01 dBm
resolution
• Remote control and data
acquisition via USB
. . . . . . . . . . . . . . . . . . p.70
• Use for install a LAN
cable or repair maintenance
• Detect Split Pairs with
Wiring Check
• Get NVP-Enhanced measurement
• Identify cable destinations
. . . . . . . . . . . . . . . . . . p.71
Magnetic Field Testing
Infrared Thermometers
MAGNETIC FIELD
MAGNETIC FIELD
HiTESTER FT3470-52 HiTESTER FT3470-51
INFRARED THERMOMETER
FT3701-20
INFRARED THERMOMETER
FT3700-20
• To measure as defined by
IEC/EN 62233
• Compliance testing of
household appliances
• Compliant to ICNIRP
2010 guidelines
• 10 Hz to 400 kHz
• Bundled with 100 cm 2
and 3 cm 2 sensors
. . . . . . . . . . . . . . . . . . p.72
• Long-focus, precise-field
type
• φ 100mm at a 3m distance
• -35.0 °C to 500.0 °C
• Measurement wavelength
8 to 14μm
• Two-beam laser marker
. . . . . . . . . . . . . . . . . . p.73
• Long-focus type
• φ 83mm at a 1m distance
• -35.0 °C to 500.0 °C
• Measurement wavelength
8 to 14μm
• Two-beam laser marker
. . . . . . . . . . . . . . . . . . p.73
• To measure as defined by
IEC/EN 62233
• Compliance testing of
household appliances
• Compliant to ICNIRP
2010 guidelines
• 10 Hz to 400 kHz
• Bundled with 100 cm 2
sensor
. . . . . . . . . . . . . . . . . . p.72
Temperature Sensing
12
TEMPERATURE
HiTESTER 3442
TEMPERATURE
HiTESTER 3441
Temperature probes
• K type thermocouple
• 1 channel
• -100.0 ˚C to 199.9 ˚C, 200
˚C to 1300 ˚C
• Recording of max. and
min. temperatures
• Waterproof structure
IP54
. . . . . . . . . . . . . . . . . . p.74
• K type thermocouple
• K type thermocouple
• 1 channel
• -100.0 ˚C to 199.9 ˚C, 200 • Pt 100
. . . . . . . . . . . . . . . . . . p.74
˚C to 1300 ˚C
• Recording of max. and
min. temperatures
. . . . . . . . . . . . . . . . . . p.74
Compact Data Logger
Series
Refer to the LR5000 series
for temperature measurement
. . . . . . . . . . . . . . . . . . p.28
Illumination / Sound Level Testing
Tachometer and Rotation Testing
SOUND LEVEL METER LUX HiTESTER 3423
FT3432
TACHO HiTESTER
FT3406
TACHO HiTESTER
FT3405
• IEC 61672-1 Class2
compliant
• 30dB to 130dB
• DC output / AC monitor
output
. . . . . . . . . . . . . . . . . . p.73
• 500mm non-contact detection
distance
• 0.5 r/sec to 99990 r/min
• Dust-proof construction
• Drop proof (1m onto concrete surface)
• Analog output and pulse output
functions
• Also power with optional AC Adapter
. . . . . . . . . . . . . . . . . . p.75
• 500mm non-contact
detection distance
• 0.5 r/sec to 99990 r/min
• Dust-proof construction
• Drop proof (1m onto
concrete surface)
• No output features
. . . . . . . . . . . . . . . . . . p.75
• 20 to 200,000 lx
• Digital
• Analog output
. . . . . . . . . . . . . . . . . . p.75
DMM/Tester Index
DMM for Electrical Work
SAFETY HiTESTER
3258
DIGITAL MULTIMETER
DT4281
DIGITAL MULTIMETER
DT4251
DIGITAL MULTIMETER
DT4221
DIGITAL HiTESTER
3255-50
DIGITAL MULTIMETER
DT4253
• Non-Metallic contact
voltage meter
• CAT IV 600 V
• 4200 count display
• True RMS
. . . . . . . . . . . . . . . . . . p.80
• Multi-function model
• 60,000 count display
• DC+AC Voltage measurement
• + Peak, - Peak measurement
• Low-pass filter function
• AC Current measurement with
Clamp-on probe
• USB communication (option)
• True RMS
• CAT IV 600 V
. . . . . . . . . . . . . . . . . . p.78
• 6,000 count display
• Low-pass filter function
• AC Current measurement
with Clamp-on probe
• USB communication
(option)
• True RMS
• CAT IV 600 V
. . . . . . . . . . . . . . . . . . p.79
• 6,000 count display
• Low-pass filter function
• No current or resistance
measurements
• True RMS
• CAT III 600 V
. . . . . . . . . . . . . . . . . . p.79
• Dust-proof and splashproof construction (IP54)
• CAT III 600 V
• 4199 count display
• Average rectified
• Measure AC load current
with optional clamp-on
probe
. . . . . . . . . . . . . . . . . . p.80
• 6,000 count display
• Low-pass filter function
• DC 60μA to 60mA measurement
• AC Current measurement with
Clamp-on probe
• USB communication (option)
• True RMS
• CAT IV 600 V
. . . . . . . . . . . . . . . . . . p.79
Index
Non-Contact Voltage Tester
for Electrical Work
DMM for Heating, Ventilation
and Air Conditioning (HVAC)
General Purpose DMM
DIGITAL MULTIMETER
DT4282
DIGITAL MULTIMETER
DT4252
DIGITAL MULTIMETER
DT4222
PENCIL HiTESTER
3246-60
SOLAR HiTESTER
3245-60
CARD HiTESTER
3244-60
• Multi-function model
• 60,000 count display
• DC+AC Voltage measurement
• + Peak, - Peak measurement
• Low-pass filter function
• 10 A Direct input
• USB communication (option)
• True RMS
• CAT IV 600 V
. . . . . . . . . . . . . . . . . . p.78
• 6,000 count display
• Low-pass filter function
• 10 A Direct input
• USB communication
(option)
• True RMS
• CAT IV 600 V
. . . . . . . . . . . . . . . . . . p.79
• 6,000 count display
• Low-pass filter function
• No current measurements
• True RMS
• CAT III 600 V
. . . . . . . . . . . . . . . . . . p.79
• New insulated test pin sleeves
prevent short-circuits
• Pencil type DMM
• CAT III 600 V
• 4199 count display
• Average rectified
• Ultra bright LED light at probe
tip
. . . . . . . . . . . . . . . . . . p.81
• New insulated test pin
sleeves prevent shortcircuits
• A card size DMM with
solar charged battery
• CAT III 600 V
• 4199 count display
• Average rectified
. . . . . . . . . . . . . . . . . . p.81
• New insulated test pin
sleeves prevent shortcircuits
• A thin card size DMM
• CAT III 300 V, CAT II
600 V
• 4199 count display
• Average rectified
. . . . . . . . . . . . . . . . . . p.81
Analog Multimeters
HiTESTER 3030-10
MULTI TESTER 3008
• Basic type analog tester
• CAT III 600V
• Average rectified
. . . . . . . . . . . . . . . . . . p.82
• Designed for maintenance of
high power lines
• High-power fuse protects, within a current limiting resistance
• Average rectified
. . . . . . . . . . . . . . . . . . p.82
High-Precision Handheld DMM
Systems Integrated Digital
Multi-Module Stations
Benchtop Multimeters for Production and Inspection Lines
DIGITAL MULTIMETER
DT4282
DIGITAL MULTIMETER
DT4281
MEMORY HiCORDER MR8741
+ DVM UNIT MR8990
DIGITAL HiTESTER
3239, 3239-01
DIGITAL HiTESTER
3238, 3238-01
DIGITAL HiTESTER
3237, 3237-01
• Multi-function model
• 60,000 count display
• DC+AC Voltage measurement
• + Peak, - Peak measurement
• Low-pass filter function
• 10 A Direct input
• USB communication (option)
• True RMS
• CAT IV 600 V
. . . . . . . . . . . . . . . . . . p.78
• Multi-function model
• 60,000 count display
• DC+AC Voltage measurement
• + Peak, - Peak measurement
• Low-pass filter function
• AC Current measurement with
Clamp-on probe
• USB communication (option)
• True RMS
• CAT IV 600 V
. . . . . . . . . . . . . . . . . . p.78
• Store entire data from 16 units
of DMM in a single operation
• Simultaneous 16 ch sampling
without signal scanner
• High ±0.01% precision & ultra
high 6-1/2 digit resolution
• 500 times/s sampling
. . . . . . . . . . . . . . . . . . p.50
• 4-terminal method resistance measurement
• Multi functional/high precision 5-1/2 digits
• 300 times/s sampling
• Comparator
• External control I/O
• RS-232C (-01 model:
GP-IB)
• True RMS
. . . . . . . . . . . . . . . . . . p.49
• Multi functional/high precision 5-1/2 digits
• 300 times/s sampling
• Comparator
• External control I/O
• RS-232C (-01 model:
GP-IB)
• True RMS
. . . . . . . . . . . . . . . . . . p.49
• Simple & Low cost type
• High precision 5-1/2 digits
• 300 times/s sampling
• Comparator
• External control I/O
• RS-232C (-01 model:
GP-IB)
• True RMS
. . . . . . . . . . . . . . . . . . p.49
Because the DMM offers a large number of measurement functions and ranges, only a representative value (maximum accuracy) for each range is
included as the basic accuracy (due to space limitations). For more accuracy information for each range, please see the detailed catalog or user manual.
13
Field Measuring Instruments Index
Index
5-Range Digital Megommeters for
Electrical Equipment Maintenance
5kV
Megommeters
INSULATION TESTER
IR4057-20
INSULATION TESTER
IR4056-20
HIGH VOLTAGE INSULATION
HiTESTER 3455
• 5 test voltage ranges from
50 to 1000 V
• Stable & high-speed
digital readings with bar
graph display
• Comparator function
• 600 V AC/DC meter
• 200 mA continuity check
• Drop Proof
• Integrated hard carrying case
. . . . . . . . . . . . . . . . . . p.83
• 5 test voltage ranges from
50 to 1000 V
• Stable digital readings
• Comparator function
• 600 V AC/DC meter
• 200 mA continuity check
• Drop Proof
• Integrated hard carrying
case
. . . . . . . . . . . . . . . . . . p.83
• 5 high voltage ranges
• 250/500/1k/2.5k/5k V
testing voltages
• Leak current, voltage,
temperature, insulation
resistance testing, data
memory
• Integrated hard carrying
case
. . . . . . . . . . . . . . . . . . p.86
3-Range Analog
Megommeters
Single-Range Analog Megommeters
ANALOG MΩ HiTESTER
3490
ANALOG MΩ HiTESTER
IR4018-20
ANALOG MΩ HiTESTER
IR4017-20
ANALOG MΩ HiTESTER
IR4016-20
• Three ranges
• 250/500/1000 V testing
voltages
• 200 mA continuity (3 Ω
resistance range)
• AC voltage measurement
• Bright LED, luminous
scale & drop proof
• Integrated hard carrying case
. . . . . . . . . . . . . . . . . . p.85
• Single range
• 1000 V testing voltage
(2000 MΩ)
• AC voltage measurement
• Bright LED, luminous
scale & drop proof
• Integrated hard carrying case
. . . . . . . . . . . . . . . . . . p.84
• Single range
• 500V testing voltage
(1000 MΩ)
• AC voltage measurement
• Bright LED, luminous
scale & drop proof
• Integrated hard carrying case
. . . . . . . . . . . . . . . . . . p.84
• Single range
• 500 V testing voltage
(100 MΩ)
• AC voltage measurement
• Bright LED, luminous
scale & drop proof
• Integrated hard carrying case
. . . . . . . . . . . . . . . . . . p.85
Ground Clamps and Earth
Resistance Testers
Non-Contact Voltage Testers and
Voltage Detectors
CLAMP ON EARTH
EARTH HiTESTER
TESTER FT6380, FT6381 3151
VOLTAGE DETECTOR
3120
SAFETY HiTESTER
3258
• Earth resistance
• Three or two electrode
measurements for multimeasurement method
grounded wires
• EN and JIS standard
• Measure currents ranging . . . . . . . . . . . . . . . . . . p.93
from leakage current to
load currents
• True RMS
• Automatic measurement
report function with
Android™ connectivity
(FT6381 only)
. . . . . . . . . . . . . . . . . . p.92
• Non-Metallic contact
• Ideal for 70 to 600 V
installations (sensitivity
fixed)
. . . . . . . . . . . . . . . . . . p.93
• Non-Metallic contact
voltage meter
• CAT IV 600 V
• 4200 count display
• True RMS
. . . . . . . . . . . . . . . . . . p.80
Phase Detectors
14
PHASE DETECTOR
3129-10
PHASE DETECTOR
3129
PHASE DETECTOR
3126-01
• Non-Metallic contact clip
• Thick conductors φ 10 to
40 mm cor dia.
• For use on 70 to 1000 V
lines (50/60 Hz)
. . . . . . . . . . . . . . . . . . p.94
• Non-Metallic contact clip
• Conductors φ 2.4 to 17
mm cor dia.
• For use on 70 to 600 V
lines (50/60 Hz)
. . . . . . . . . . . . . . . . . . p.94
• Metallic clip contact
• Rotary disk style
• For use on 110 to 480 V
lines (40 to 70 Hz)
. . . . . . . . . . . . . . . . . . p.94
Clamp Meters/Options and Peripherals Index
Index
AC Current Leakage Clamp Meters
CLAMP ON EARTH
CLAMP ON LEAK HiTESTER CLAMP ON LEAK HiTESTER
TESTER FT6380, FT6381 3293-50
3283
• Earth resistance
measurements for multigrounded wires
• Measure currents ranging
from leakage current to
load currents
• True RMS
• Automatic measurement
report function with
Android™ connectivity
(FT6381 only)
. . . . . . . . . . . . . . . . . . p.92
• True RMS
• AC leak current / load
current measurement
• 30 mA range 10 µA
resolution
• Load current up to 1000 A
• Reversible display
technology
• Filter function
. . . . . . . . . . . . . . . . . . p.87
• True RMS
• AC leak current / load
current measurement
• 10 mA range 10 µA
resolution
• Load current up to 200 A
• Filter function
• Analog / monitor output
. . . . . . . . . . . . . . . . . . p.87
AC Current Clamp Meters for Electrical Work
CLAMP ON HiTESTER
3291-50
DIGITAL CLAMP ON HiTESTER DIGITAL CLAMP ON HiTESTER DIGITAL CLAMP ON HiTESTER DIGITAL CLAMP ON HiTESTER CLAMP ON ADAPTER
3282
3281
3280-20
3280-10
9290-10
• True RMS
• Load current 60 to 1000A
• Reversible display
technology
• Filter function
. . . . . . . . . . . . . . . . . . p.88
• True RMS
• 30 to 1000 A AC range
• Wave peak value at
inrush current
• Waveform distortion
check
. . . . . . . . . . . . . . . . . . p.91
• True RMS
• 30 to 600 A AC range
• Wave peak value at
inrush current
• Waveform distortion
check
. . . . . . . . . . . . . . . . . . p.91
• True RMS
• 42 to 1000 A AC range
• Light weight 100 g, 16
mm thin body
• DMM function
. . . . . . . . . . . . . . . . . . p.91
• Average rectified
• 42 to 1000 A AC range
• Light weight 100 g, 16
mm thin body
• DMM function
. . . . . . . . . . . . . . . . . . p.91
• CT for measuring the
secondary current 1/10 of
primary 1000A
• Superior phase angle
characteristics for power
. . . . . . . . . . . . . . . . . . p.95
AC/DC Current Clamp Meters for General Industrial Applications
AC Current Clamp Meters for
Power and Phase Testing
CLAMP ON AC/DC HiTESTER CLAMP ON AC/DC HiTESTER CLAMP ON AC/DC HiTESTER CLAMP ON AC/DC HiTESTER CLAMP ON AC/DC HiTESTER
3290, 3290-10
3288-20, 3288
3287
3285-20, 3285
3284
CLAMP ON POWER
HiTESTER 3286-20
• For AC/DC measurement
• True RMS
• 20/ 200/ 2000 A range
• DC/ AC+DC/ AC/ PEAK
• Record output (4 types, 2
groups)
(3290-10)
• Current integral/
Operating time ratio
measurement
. . . . . . . . . . . . . . . . . . p.88
• Easy AC power checker
• Single-phase, 3-phase
(balanced load only)
• Phase angle, power factor,
harmonic levels
• True RMS
• For AC measurement
• Battery operation
. . . . . . . . . . . . . . . . . . p.89
• For AC/DC measurement
(3288-20) True RMS
(3288) Average rectified
• 100/ 1000 A range
• Light weight 150 g, 16
mm thin body
• DMM function
. . . . . . . . . . . . . . . . . . p.89
• For AC/DC measurement
• True RMS
• 10/ 100 A range
• Light weight 170 g, 16
mm thin body
• DMM function
. . . . . . . . . . . . . . . . . . p.89
• For AC/DC measurement
• True RMS
• 200/ 2000 A range
• DC/ AC/ AC+DC mode
• Peak value at inrush
current
• Efficient value at half
wave rectifier
(3285-20) Added
Resistance function
. . . . . . . . . . . . . . . . . . p.90
• For AC/DC measurement
• True RMS
• 20/ 200 A range
• DC/ AC/ AC+DC mode
• Peak value at inrush
current
• Efficient value at half
wave rectifier
. . . . . . . . . . . . . . . . . . p.90
Custom Meter Relays for
Systems Integration
Current Transformers
Shunts and Multipliers
METER RELAY
2104H/L/HL
METER RELAY
2103H/L/HL
CURRENT TRANSFORMER
CT-5MRN series
EXTERNAL SHUNTS
HS-1 series
• 1 channel analog scale
• Electronic design assures
high accuracy and reliability
• 100 mm (3.94 in) width
(H type) upper-limit setting
(L type) lower-limit setting
(HL type) upper/lowerlimit setting
. . . . . . . . . . . . . . . . . . p.96
• 1 channel analog scale
• Electronic design assures
high accuracy and reliability
• 80 mm (3.15 in) width
(H type) upper-limit setting
(L type) lower-limit setting
(HL type) upper/lowerlimit setting
. . . . . . . . . . . . . . . . . . p.96
• For 50/60 Hz lines only
• Rated load 5 VA
• Polyester resin mold type
. . . . . . . . . . . . . . . . . . p.95
• Use in combination with a
50 mV meter
• 30A to 300A
. . . . . . . . . . . . . . . . . . p.95
15
Recorders • Data Loggers
Capture high- to low-voltage signals in a single device! Rugged, Professional and Ready for the Field
MEMORY HiCORDER MR8880-20
■ Basic specifications (Accuracy guaranteed for 1 year)
4 analog channels + 8 logic channels (standard)
Note: Isolated analog channels, isolated input and frame, logic has common GND
4 channels of voltage measurement; mode switchable between instantaneous waveform or
RMS value, 10 mV to 100 V/div, 13 ranges, resolution: 1/640 of range
RMS value mode: 30 Hz to 10 kHz, Crest factor: 2
Between terminals: 600 V AC/DC, Between terminal to earth: 600 V AC/DC
CAT III; 300 V AC/DC CAT IV
DC to 100 kHz (±3dB)
Number of channels
Measurement ranges
(10 div full-scale)
Recorders
Data Loggers
marked
Max. rated voltage
Frequency characteristics
Time axis
Printer docks onto main unit
(High-speed function)
100 µs to 100 ms/div, 10 ranges, Sampling period: 1/100 of range
Recording intervals
(Real-time function)
100 µs to 1 minute, 19 selections (simultaneous sampling in all channels)
Measurement functions
Memory capacity
Removable storage
High-speed function (high speed recording)
Real-time function (actual time recording)
14-bits × 1M-words/ch (1 word = 2 bytes)
CF card slot ×1 (Up to 2 GB), USB 2.0 memory ×1
[Printer unit is option] 112 mm (4.41 in) × 18 m (59.06 ft), thermal paper roll,
Recording speed : 10 mm (0.39 in)/sec
Printing
Note: Printing is not supported when using alkaline batteries
Printer unit is optional
• CAT III 600V isolation performance; directly measure a 480V power line
• 4 completely isolated channels let you simultaneously record data on a 3-phase power
line plus have one extra channel
• Tough against harsh environments; -10°C to 50°C operating temperature range
• Built to withstand mechanical shocks and vibrations (ships standard with side protectors)
• Make settings easily with PRESETS function
Note: Input cords and Battery Pack are not included. Purchase the cords appropriate for your
application separately. Printer Unit MR9000 is optional and sold separately.
5.7-inch VGA-TFT color LCD (640 × 480 dots)
Display
Displayable languages English, Japanese, Chinese
Communication inter- USB 2.0 mini-B receptacle × 1; Transfers files from the installed CF card or USB
memory stick to a PC when connected, and External PC control
faces
AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 11 VA (when Real-time recording), 40 VA
(when Real-time recording and printing)
Battery pack Z1000: AC adapter has priority when used in combination with battery pack,
recharge with AC adapter 3 hours, Continuous use 3 hours (with back-light ON)
Power supply
LR6 (AA) alkaline batteries ×8, Continuous use 40 minutes, (with back-light ON, cannot be
used with the Printer unit)
DC power supply: 10 to 28 V DC (cable available by special order)
205 mm (8.07 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D, 1.66 kg (58.6 oz) (with the
Battery pack installed)
Dimensions and mass When printer is combined - with main unit: 303 mm (11.93 in)W × 199 mm (7.83 in)H × 67
mm (2.64 in)D, 2.16 kg (76.2 oz) (with the Battery pack installed)
Instruction manual ×1, AC adapter Z1002 ×1, Alkaline battery box ×1, Strap ×1, USB cable
Accessories
×1, Application disk (Wave viewer Wv, Communication commands table) ×1
Other options refer to the detailed catalog
Printing width 100 mm (3.94 in), used
together with the MR8880-20 main body,
includes 1 roll of recording paper
AC ADAPTER Z1002
BATTERY PACK Z1000
Included as standard, for
main unit, 100 to 240 V AC
NiMH, Charges while installed
in the main unit
CARRYING CASE C1003
Includes compartment for
options, soft case type
Options
Exclusive use options
PRINTER UNIT MR9000
RECORDING PAPER 9234
112 mm (4.41 in) × 18 m (59.06 ft),
roll type, 10 rolls/set
PC CARD 2G 9830 (2 GB capacity)
PC CARD 1G 9729 (1 GB capacity)
PC CARD 512M 9728 (512 MB capacity)
PC CARD 256M 9727 (256 MB capacity)
Smart Design - Smart Engineering
MEMORY HiCORDER MR8875
■ Basic specifications (Accuracy guaranteed for 1 year)
Number of input units Up to 4 slots
Max. 16 analog channels (Max. 60 channels when using the MR8902) + standard 8
logic channels + 2 pulse channels
Number of channels Note:
For analog units, channels are isolated from each other and from the MR8875’s GND. For CAN
unit ports or standard logic terminals or standard pulse terminals, all channels have common GND.
Measurement ranges 5 mV to 10 V/div (20 div full-scale), 11 ranges, resolution : 1/1250 of range (when using the MR8901)
Between terminals: 150 V DC
Max. rated voltage
Between terminal to earth: 100 V AC, DC (when using the MR8901)
Frequency characteristics DC to 100 kHz (-3 dB, when using the MR8901)
200 µs to 5 min/div, 21 ranges, sampling period: 1/100 of range, External sampling possible
Time axis
[When using MR8901] 500 kS/s (2 μs period, all channels simultaneously)
[When using MR8902] 10 ms (all input channels are scanned at high speed during every recording interval)
Max. sampling rate
[When using MR8903] 200 kS/s (5 μs period, all channels simultaneously)
External sampling: 200 kS/s (5 μs period)
Measurement func- High-speed function (high speed recording), Real-time calculation between channels,
FFT calculation, or other functions
tions
Total 32 M-words (memory expansion: N/A, 8 MW each input unit)
Storage memory
Note: 1 word = 2 bytes, therefore 32 Mega-words = 64 Mega-bytes.
capacity
Note: Storage memory can be allocated depending on the number of channels used at each input unit
marked
• Measure multiple channels simultaneously despite handheld portable design
• Max. 2 μsec high-speed simultaneous logging for all input channels
• Save directly to the SD Card in real time for uninterrupted long-term logging
• 16-bit high-resolution measurement of voltage, temperature, distortion and CAN signals
• FFT calculation, waveform calculation functions for advanced analysis
• Intuitive touch screen for optimal operability
• Tough against vibrations and extreme temperatures, with strengthened body ideal for
in-vehicle testing and road tests
• 3 different power supplies
Note: Test leads are not included. Purchase the leads appropriate for your application separately. AC Adapter Z1002 is included as standard.
Removable storage
Display
Communication inter- E-mail, command control)
USB: USB 2.0 compliant, series mini-B receptacle ×1 (setting / measure with commufaces
nication command, or file transfer SD card to PC), series A receptacle ×2 (USB memory,
USB mouse/ key-board)
1) AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 56 VA
2) Battery pack Z1003: 7.2 V DC, 36 VA, continuous operation time: 1 hour with
back light ON (AC adapter has priority when used in combination with battery pack),
Charges while installed in the MR8875, recharging time: 3 hours
3) External DC Power: 10 to 28 V DC, 56 VA, (please contact your HIOKI distributor
Power supply
for connection cord)
298 mm (11.73 in)W × 224 mm (8.82 in)H × 84 mm (3.31 in)D, 2.4 kg (84.7 oz), (excluding
Dimensions and mass input units and the Battery pack Z1003)
Reference data: 3.47 kg/ 122.4 oz (including the MR8901 ×4 units and the Battery pack Z1003)
Instruction manual ×1, Measurement guide ×1, AC adapter Z1002 ×1, Protection
sheet ×1, USB cable ×1, Shoulder strap ×1, Application disk (Wave viewer Wv,
Accessories
communication commands table, CAN Editor) ×1
SD Card Precaution
BATTERY PACK
Z1003
Included as standard, for
main unit, 100 to 240 V
AC
NiMH, Charges while
installed in the main unit
CAN CABLE 9713-01
For the MR8904,
unprocessed on one end,
1.8 m (5.91 ft) length
Use only SD Cards sold by
HIOKI. Compatibility and
performance are not guaranteed for SD cards made
SD MEMORY CARD by other manufacturers. You
2GB Z4001
may be unable to read from
For storing measurement or save data to such cards.
data
Input modules
Exclusive use options
ANALOG UNIT MR8901
Other options refer to the detailed catalog
AC ADAPTER Z1002
SD card slot ×1, USB 2.0 memory
Touch-panel operation 8.4-inch SVGA-TFT color LCD (800 × 600 dots)
LAN: 100BASE-TX (DHCP, DNS supported, FTP server/ client, WEB server, send
4ch, Voltage measurement, DC to 100kHz bandwidth
VOLTAGE/TEMP UNIT MR8902
15ch, Voltage measurement, Thermocouple measurement
STRAIN UNIT MR8903
4ch, Voltage measurement, Strain gauge converter input, Conversion
cable included
CAN UNIT MR8904
up to 15 analog channels each equivalent to a 16-bit analog signal,
and up to 16 logic channels each equivalent to a 1-bit logic signal
(Install by inserting into the main unit. Can be replaced by user. Input cables are not supplied.)
16
Recorders • Data Loggers
Easy recording anytime, anywhere!
MEMORY HiCORDER 8870-20
■ Basic specifications (Accuracy guaranteed for 1 year)
Number of channels
Measurement ranges 10 mV to 50 V/div (10 div full-scale), 12 ranges, Resolution: 1/100 of range
400 V DC
Max. input voltage
Frequency characteristics DC to 50 kHz (-3 dB)
100 µs to 5 min/div, 20 ranges,at 100 points/div resolution, three steps of time-axis magTime axis
nification from ×2 to ×10, and 9 steps of time-axis compression from ×1/2 to ×1/1,000
Measurement functions Memory recorder (high speed recording)
12-bits × 2M-words/ch (1 word = 2 bytes)
Memory capacity
CF card TYPE I slot ×1 (Up to 2 GB)
Removable storage
4.3-inch WQVGA-TFT color LCD (480 × 272 dots)
Display
Displayable languages English, Japanese Note: Korean (special order only, please contact HIOKI)
USB 2.0 mini-B receptacle ×1; Transfers files from the installed CF card to a PC
when connected (mass storage class device)
External interfaces
Recorders
Data Loggers
marked
2 analog channels + 4 logic channels (standard)
Note: Isolated analog channels, isolated input and frame, logic has common GND
Note: The CF card installed in the HiCorder appears as a removable disk on the PC, but communication
functions such as the capability to change HiCorder settings from the PC are not provided.
•Compact and easy to carry
•Easy, intuitive operation
•Simple PC connection
•Fast, 1MS/s performance despite the compact size
•Built-in, compact-yet-sharp QVGA-TFT wide LCD
Printer
Power supply
Charging functions
Note: Input cords and Battery pack are not included. Purchase the cords appropriate for your
application separately. The AC Adapter Z1005 is included as standard.
N/A
AC adapter Z1005: 100 to 240 V AC (50/60 Hz), 30 VA Max.
Battery pack 9780: Continuous use 2 hours (AC adapter has priority when both are used)
12 V DC supply: 10 to 16 V, 10 VA Max. (Cable available by special order)
The installed battery pack charges when the AC adapter is connected. Charging
time is about 200 minutes at 25°C.
Notes: Charging time depends on battery condition. Charging is disabled to protect the
battery at ambient temperatures out of 5°C to 30°C (41°F to 86°F)
Dimensions and mass
176 mm (6.93 in)W × 101 mm (3.98 in)H × 41 mm (1.61 in)D, 600 g (21.2 oz) (with the
Accessories
Instruction manual ×1, Measurement guide ×1, AC adapter Z1005 ×1, Strap ×1,
USB cable ×1, Application disk (Dedicated program for the 8870-20/-21) ×1,
Protection sheet 9809 ×1
Battery pack 9780 installed)
Other options refer to the detailed catalog
NiMH, Charges while
installed in the main unit
SOFT CASE 9812
Includes space for small
items, Neoprene rubber
CARRYING CASE 9782
Includes compartment for
options, Resin coated
Accessories
Options
BATTERY PACK 9780
PROTECTION SHEET 9809
For LCD protection, pairs of additional sheets can
be purchased separately, bundled with instrument
AC ADAPTER Z1005
100 to 240 V AC, bundled
with instrument
As an Oscilloscope, As a Data Logger! Record Waveforms in Any Situation
MEMORY HiCORDER 8860-50, 8861-50
Right side
Goods on the
market
marked
8860-50
■ Basic specifications (Accuracy guaranteed for 1 year)
8860-50
8861-50
Max. 8 units
Number of input units Max. 4 units
Max. 16 analog channels (Max. 64 channels Max. 32 analog channels (Max. 128 channels
when using the 8958) + standard 16 logic
when using the 8958) + standard 16 logic
Number of channels
channels
channels
Measurement ranges 5 mV to 20 V/div, 12 ranges (when using 5 mV to 20 V/div, 12 ranges (when using
the 8956), Resolution : 1/100 of range
the 8956), Resolution : 1/100 of range
(20 div full-scale)
DC 400 V (when using the 8956)
Max. allowable input DC 400 V (when using the 8956)
Frequency characteristics DC to 10 MHz (-3 dB, when using the 8956) DC to 10 MHz (-3 dB, when using the 8956)
Time axis (MEMORY 5 µs to 5 min/div, 26 ranges, sampling period : 1/100 of range, external sampling,
operation)
dual time-base possible
MEM (high-speed recording), REC (real-time recording), REC & MEM (real-time recording + highMeasurement
speed recording), FFT (frequency analysis), Real-time Save (records directly to storage media)
functions
12-bits × 32M-words/ch (1ch at 8860-50, 2ch at 8861-50) to 2M-words/ch (16ch at 8860Storage memory
50, 32ch at 8861-50)
capacity
*Memory capacity can be expanded 32 times. (Optional memory board)
Removable storage
8861-50
•A faster CPU greatly enhances instrument operability and response.
•Multi-channel logging on up to 64 or 128 channels (Use with the 8958)
•20 MS/s high-speed sampling (Use with the 8956)
•Various interfaces built-in: LAN/USB/PC-card slot
•Supports the new high-voltage input module for measuring high voltage directly
Recording paper
Display
External interfaces
Power supply
USB 2.0 memory ×3, PC card Type II slot ×2, Hard disk drive (option) ×1
[Built in optional printer unit] A4: 216 mm (8.50 in) × 30 m (98.43 ft), or A6: 112 mm (4.41 in) ×
18 m (59.06 ft) selectable, thermal paper roll, Recording speed : Max. 25 mm (0.98 in)/s
10.4-inch SVGA-TFT color LCD (800 × 600 dots)
GP-IB, USB 2.0, LAN, Monitor output (15 pin D-sub output)
100 to 240 V AC (50/60 Hz) (220 VA max. 100 to 240 V AC (50/60 Hz) (280 VA max.
printer not used)
12 V DC (use the DC power unit 9684 :
option, factory installation only)
The Memory HiCorder 8860-50 and 8861-50 cannot operate alone. You must install one or more
optional input modules in the unit.
Note: Memory boards are not built-in as a standard feature. Choose one board for Model 8860-50,
and two of the same capacity for the 8861-50, for factory pre-installation.
Note: Memory boards are not built in as a standard feature.
Choose one board for Model 8860-50, and two of the same
capacity for the 8861-50, for factory pre-installation.
Factory-installed option. Either 8995
or 8995-01 printer can be installed.
Printing width 200 mm (7.87 inch).
Compatible recording paper: Model
9231
MEMORY BOARD 9715-50 (32 Megaword capacity)
MEMORY BOARD 9715-51 (128 Megaword capacity) A6 PRINTER UNIT 8995-01
Factory-installed option. Either 8995
MEMORY BOARD 9715-52 (512 Megaword capacity) or 8995-01 printer can be installed.
Printing width 100 mm (3.94 inch).
MEMORY BOARD 9715-53 (1 Gigaword capacity)
HD UNIT 9718-50 80 GB, built in the main unit.
Compatible recording paper: Model
9234
Options
Factory-installed options
A4 PRINTER UNIT 8995
option, factory installation only)
330 mm (12.99 in)W × 250 mm (9.84 in)H × 330 mm (12.99 in)W × 250 mm (9.84 in)H
Dimensions and mass 184.5 mm (7.26 in)D, 8 kg (282.2 oz) (printer × 284.5 mm (11.20 in)D, 10.5 kg (370.4 oz)
not installed)
Accessories
Other options refer to the detailed catalog
printer not used)
12 V DC (use the DC power unit 9684 :
(printer not installed)
Quick start manual ×1, Input module guide ×1, Instruction manual ×1, Analysis and
communication supplement ×1, Application disk (Wave viewer Wv, communication
commands table) ×1, Power cord ×1, Input cord label ×1, Ferrite clamp (for LAN cable) ×1
ANALOG UNIT 8956
VOLTAGE/TEMP UNIT 8937
2 ch, Voltage input, DC to 10 MHz bandwidth
2 ch, Voltage or Temperature input with thermocouple
HIGH RESOLUTION UNIT 8957
FFT ANALOG UNIT 8938
2 ch, Voltage input, DC to 200 kHz bandwidth, built in filter for FFT 2 ch, Voltage input, DC to 400 kHz bandwidth,
built in filter for FFT
16ch SCANNER UNIT 8958
16 ch, Voltage or Temperature input with thermocouple
STRAIN UNIT 8939
2 ch, Distortion measurement for strain gauge converter
DC/RMS UNIT 8959
2 ch, Voltage, DC to 400 kHz, or RMS rectifier DC/20 to 100 kHz F/V UNIT 8940
2 ch, Frequency, Voltage input, Current input with clampSTRAIN UNIT 8960
2 ch, Distortion measurement for strain gauge converter
on sensor
HIGH VOLTAGE UNIT 8961
4ch ANALOG UNIT 8946
2 ch, Voltage input, DC/RMS selectable
Note: Maximum 4 units in one the Model 8861-50
4 ch, Low voltage input, DC to 100 kHz bandwidth
ANALOG UNIT 8936
2 ch, Charge-output type piezoelectric acceleration pick-up sensor,
Acceleration pick-up sensor with an internal preamp
2 ch, Voltage input, DC to 400 kHz bandwidth
RECORDING PAPER
9231
A4 width 216 mm (8.50 in)
× 30 m
(98.43 ft), 6 rolls/set
RECORDING PAPER
9234
A6 width 112 mm (4.41 in)
× 18 m
(59.06 ft), 10 rolls/set
CHARGE UNIT 8947
(Install by inserting into the main unit. Can be replaced by user. Input cables are not supplied.)
17
Recorders • Data Loggers
The Ideal Recorder for Field Use, Easy Portability and Sturdy Construction
MEMORY HiCORDER MR8847-01/-02/-03
■ Basic specifications (Accuracy guaranteed for 1 year)
Number of channels
[8 analog input modules]: 16 analog channels + 16 logic channels (standard)
[5 analog input modules + 3 logic input modules]: 10 analog channels + 64 logic
channels (standard 16 channels + 48 channels in logic input modules)
* For analog modules, channels are insulated vs. each other and vs. unit ground.
For logic modules and integrated standard logic channels, all channels use the unit ground.
Recorders
Data Loggers
marked
•Choice of memory capacity from 64-Mega word (-01 model) to 512-Mega word (-03 model)
•High-speed sampling with waveform judgment function
•High-speed sampling up to 20MS/s with fully isolated inputs
•16 analog + 16 logic channels to 64 logic + 10 analog channels
•Large, tough handle makes carrying a snap
•Soil-resistant construction is strong against adverse working environments
•Big buttons are coated to withstand industrial oil and residue
•Drop-in paper loading and one-touch setup, along with high 50 mm/s printing speed
Measurement ranges 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (using the 8966)
(20 div full-scale)
5 mV to 20 V/div, 12 ranges, resolution : 1/1600 of range (using the 8968)
Max. allowable input 400 V DC (using the 8966/8968)
Frequency characteristics DC to 5 MHz (-3 dB, using the 8966), DC to 100 kHz (-3 dB, using the 8968)
5 µs to 5 min/div, 26 ranges,at 100 points/div resolution, three steps of time-axis
Time axis (MEMORY
magnification from ×2 to ×10, and 13 steps of time-axis compression from ×1/2 to
operation)
×1/20,000
Measurement func- MEMORY (high-speed recording), RECORDER (real-time recording),
X-Y RECORDER (X-Y real-time recording), FFT
tions
Waveform judgment (at Memory, X-Y recorder, or FFT function)
Other functions
MR8847-01: 32M-words/ch (using 2 Analog channels) to 4M-words/ch (using 16 Analog
channels), Total capacity 64MW memory
MR8847-02: 128M-words/ch (using 2 Analog channels) to 16M-words/ch (using 16 Analog
Memory capacity
channels), Total capacity 256MW memory
MR8847-03: 256M-words/ch (using 2 Analog channels) to 32M-words/ch (using 16 Analog
channels), Total capacity 512MW memory
Data storage media USB memory, CF card slot × 1 (Up to 2 GB), Hard disk drive (option, 80GB)
216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s
Printing
10.4 inch TFT color LCD (SVGA, 800 × 600 dots)
Display
Displayable languages English, Japanese, Korean, Chinese
[LAN]: 100BASE-TX; Functions: DHCP, DNS supported, FTP server, HTTP server
External interfaces
[USB]: USB2.0 compliant, series A receptacle 1 port, series B receptacle 1 port (file
transfer to PC, remort control from PC)
MR8847-01 (64MW memory, main unit only)
MR8847-02 (256MW memory, main unit only)
MR8847-03 (512MW memory, main unit only)
100 to 240 V AC, 50/60 Hz (130 VA max., when using printer: 220 VA max.)
10 to 28 V DC (when using the optional factory-installed DC power unit 9784)
Dimensions and mass 351 mm (13.82 in)W × 261 mm (10.28 in)H × 140 mm (5.51 in)D, 7.8 kg (275.1 oz) (main unit only)
Instruction manual ×1, Measurement guide ×1, Application disk (Wave viewer Wv,
Communication commands table) ×1, Power cord ×1, Input cord label ×1, USB cable
Accessories
×1, Printer paper ×1, Roll paper attachment ×2, Ferrite clamp ×1
Power supply
* Main unit MR8847-01/ -02/ -03 cannot operate alone. You must install one or more optional
input modules in the unit.
Install by inserting into the main unit. Can be replaced by user.
DC POWER UNIT 9784
HD UNIT 9664
Factory-installed
option. 80GB
Options
Factory-installed options
Other options refer to the detailed catalog
Factory-installed option - not user
installable, built in on the bottom
case. 10 to 28 V DC drive.
ANALOG UNIT 8966
FREQ UNIT 8970
2 ch, Voltage input, DC to 5 MHz bandwidth
2 ch, for frequency, rotation, pulse measurement, available from the
8847 Ver 2.00 or later
TEMP UNIT 8967
2 ch, Temperature input with thermocouple
CURRENT UNIT 8971
2 ch, Voltage input, DC to 100 kHz bandwidth
2 ch, for current measurement with current sensor, available from the
8847 Ver 2.00 or later
HIGH RESOLUTION UNIT 8968
STRAIN UNIT 8969
2 ch, Distortion measurement for strain gauge
converter, Conversion Cable 9769 bundled
DC/RMS UNIT 8972
2 ch, Voltage, DC to 400 kHz, or RMS rectifier DC/30 to 100 kHz
RECORDING PAPER
9231
Four terminal, 16 channels
A4 width 216 mm (8.50 in) ×
30 m (98.43 ft), 6 rolls/set
LOGIC UNIT 8973
32-channel recorder with large display and wide printer installed
MEMORY HiCORDER 8826
■ Basic specifications (Accuracy guaranteed for 1 year)
Number of input units Max. 16 units
32 analog channels + 32 logic channels (Isolated analog channels, isolated input and
Number of channels
marked
frame, logic has common GND)
5 mV to 20 V/div, 12 ranges, resolution : 1/80 of range (using the 8936), Full-scale:
20 div (Normal), 24 div (Wide)
Max. allowable input 400 V DC (using the 8936)
Frequency characteristics DC to 400 kHz (±3 dB, using the 8936)
Time axis (MEMORY 100 µs to 5 min/div, 20 ranges, Sampling period: 1/100 of range (100 points/div resooperation)
lution), External sampling possible
Measurement func- Memory recorder, Recorder, X-Y recorder, RMS recorder (50/60 Hz or DC only),
Recorder and Memory, FFT
tions
12-bits × 4M-words/ch (using 4 Analog channels) to 500k-words/ch (using 32 Analog
Memory capacity
channels), Note: Memory capacity can be expanded 4 times
Data storage media PC card type III slot ×1, Flash ATA (up to 2GB), FD drive (MS-DOS)
GP-IB: using the 9558 GP-IB card.
Measurement ranges
Note: Model 9558 has been discontinued; new GP-IB applications are not supported
•Simultaneous sampling, display and recording of all 32 analog and 32 logic
channels
•High resolution of 12-bit, 1 M-sampling /second
•B4-size (paper width 264 mm) wide printer
•Large capacity memory of max. 16M-words. Memory expandable four times
(option)
* Main unit 8826 cannot operate alone. You must install one or more optional input modules in
the unit.
Interfaces (option)
RS-232C: using the 9557 RS-232C card.
Note: Model 9557 has been discontinued; new RS-232C applications are not supported
LAN: using a HIOKI-tested LAN card.
Note: The LAN card from HIOKI has been discontinued; new LAN applications are not supported
Printing
Display
Power supply
Dimensions and mass
Accessories
264 mm (10.39 in) × 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 25 mm (0.98 in)/s
10.4 inch TFT color LCD (640 × 480 dots)
100 to 240 V AC, 50/60 Hz, 300 VA max. (at use with the 8936 16 units), 100 VA at printer OFF
401 mm (15.79 in)W × 235 mm (9.25 in)H × 382 mm (15.04 in)D, 11 kg (388 oz) (main unit only)
Power cord ×1, Printer paper ×1, Protective cover ×1, Roll paper attachment ×2, PC
card protector ×1, Connection cord label ×1, Instruction manual ×1, Application
disk (Wave viewer Wv, Communication commands table) ×1
Install by inserting into the main unit. Can be replaced by user.
ANALOG UNIT 8936
F/V UNIT 8940
2 ch, Voltage input, DC to 400 kHz bandwidth
2 ch, Frequency, Voltage input, Current input with clamp-on sensor
(8826 Ver. 2.10 or later can be used, Current probes with a serial
number of No. 1999-0338386 or later can be used, older types cannot
be used.)
VOLTAGE/TEMP UNIT 8937
Options
Factory-installed option
18
Other options refer to the detailed catalog
MEMORY BOARD 9599
Expands main unit memory by 4×,
Note: user installable
2 ch, Voltage or Temperature input with thermocouple
FFT ANALOG UNIT 8938
2 ch, Voltage input, DC to 400 kHz bandwidth, built in filter for FFT
CHARGE UNIT 8947
2 ch, Distortion measurement for strain gauge converter
2 ch, Charge-output type piezoelectric acceleration pick-up sensor,
Acceleration pick-up sensor with an internal preamp
(Used with the 8826, Ver. 2.20 or later)
STRAIN UNIT 8939
4ch ANALOG UNIT 8946
4ch, Low voltage input, DC to 100kHz bandwidth,
(Cannot be used with the 8826.)
RECORDING PAPER
9229
264 mm (10.39 in) × 30 m
(98.43 ft), 6 rolls/set
RECORDING PAPER
9229-01
Perforated type, 264 mm
(10.39 in) × 30 m (98.43 ft),
6 rolls/set
Recorders • Data Loggers
High-speed/isolated multichannel measurement system recorders (rack-mounted)
MEMORY HiCORDER MR8740, MR8741
■ Basic specifications (Accuracy guaranteed for 1 year)
MR8740
MR8741
+ 48 ch logic unit)
[8 analog units]
From 16 ch analog + 16 ch standard logic
[Block II: 11 analog units]
[5 analog units + 3 logic units]
From 22 ch analog + 8 ch standard logic
10 ch analog + 64 ch logic (16 standard logic +
[Block II: 8 analog units + 3 logic units]
16 ch analog + 56 ch logic (8 ch standard logic 48 logic unit)
marked
Number of channels
MR8740 (54ch Max.)
+ 48 ch logic unit)
*Instrument consists of two blocks, Block I and
Block II.
*Block I and Block II start measurement simultaneously by means of trigger synchronization
(internal setting)
MR8741 (16ch Max.)
• Introducing the DVM Unit MR8990 with high 24-bit resolution! Perform high-speed, highaccuracy measurement without going through a scanner.
• Support for multichannel measurement (MR8740: up to 54 ch; MR8741: up to 16 ch)
• Isolated input (between input channels; input-to-chassis isolation: maximum input-to-ground rated voltage of 300 V AC/DC)
*Analog unit channels are isolated from each other and from chassis. Logic unit channels and
standard logic terminal channels share a common GND with chassis.
Measurement ranges 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (when using 8966)
(20 div full scale)
5 mV to 50 V/div, 5 ranges, resolution : 1/50,000 of range (when using MR8990)
400 V DC (when using 8966; upper limit voltage that can be applied between input termiMax. allowable input
nals without damage)
• High-speed sampling (max. 20 MS/s; with 54-ch type, simultaneous sampling of up to 32 ch)
• Ideal for rack-mounting (4U height/within 180 mm; display-less, box-type design)
• Remote measurement via LAN communications (data stored in built-in memory; operate remotely from a PC)
• MR8740 (54-ch model, 864 MW memory, main unit only)
• MR8741 (16-ch model, 256 MW memory, main unit only)
* Main unit MR8740/8741 requires input units and other dedicated options. Input cords
not included. For more information about input cords and other common options, refer
to the detailed catalog.
Mix and match input units to install into the main unit. For other options, please see the product catalog.
Options
DIGITAL VOLTMETER UNIT MR8990
2 ch, high-precision DC V input, 0.1 μV
resolution, high-speed sampling 500 times/s
ANALOG UNIT 8966
2 ch, voltage input, DC to 5 MHz bandwidth
TEMP UNIT 8967
2 ch, thermocouple temperature input
HIGH RESOLUTION UNIT 8968
2 ch, voltage input, DC to 100 kHz bandwidth
Recorders
Data Loggers
[Block I: 16 analog units]
From 32 ch analog + 8 ch standard logic
inputs
[Block I: 13 analog units + 3 logic units]
26 ch analog + 56 ch logic (8 ch standard logic
STRAIN UNIT 8969
2 ch, strain gauge type converter amp
*Includes Conversion Cable 9769
FREQ UNIT 8970
2 ch, for measurement of frequency, rpm,
pulse, etc.
DC/RMS UNIT 8972
2 ch, voltage/DC to 400 kHz, RMS rectifier,
DC and 30 to 100 kHz bandwidth
LOGIC UNIT 8973
4 terminals, 16 ch
CURRENT UNIT 8971
2 ch, for measuring current using dedicated
current sensors, use up to 4 with MR8740;
not compatible with MR8741
Max. rated voltage to 300 V AC/DC (input and instrument are isolated; between input channels and chassis;
upper limit voltage that can be applied between input channels without damage)
earth
Frequency characteristics DC to 5 MHz (-3 dB, when using 8966)
Time axis (MEMORY 5 µs to 5 min/div; 26 ranges; time axis resolution: 100 points/div; time axis expanoperation)
sion: 3 stages from ×2 to ×10; compression: 13 stages from 1/2 to 1/20,000
Measurement functions Memory (high-speed recording), FFT
16 MW/ch (fixed), total of 864 MW installed 16 MW/ch (fixed), total of 256 MW installed
Memory capacity
USB memory stick (USB 2.0)
External storage
None (1 digital DVI terminal per block, 800 × 600 dots) None (1 digital DVI terminal, 800 × 600 dots)
Display
[LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server)
External interfaces
[USB] USB 2.0 Series A receptacle × 2 (mouse operation)
100 to 240 V AC, 50/60 Hz (250 VA max.) 100 to 240 V AC, 50/60 Hz (120 VA max.)
Power supply
426 mm (16.77 in)W × 177 mm (6.97 in)H 350 mm (13.78 in)W × 160 mm (6.30 in)H
Dimensions and mass × 505 mm (19.88 in)D, 10.8 kg (381.0 oz) × 320 mm (12.60 in)D, 5.4 kg (190.5 oz)
(main unit only)
(main unit only)
Instruction manual ×1, Application disk (Wave viewer Wv, Communication commands table) ×1,
Power cord ×1
Accessories
Easy data recording as convenient as a simple tester, yet with broad functionality
MICRO HiCORDER 8205-10, 8206-10
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
8205-10
8206-10
1 channel AC voltage and 1 channel
1 channel AC or DC voltage, or 1
AC current
AC current
(Simultaneous recording using alternating
Number of channels channel
(Simultaneous recording not supported; 1 ch
only; isolated input for voltage)
Discontinued
duled
Discontinue sche
8205-10
8206-10
•Model 8205-10 provides one channel for recording either AC/DC voltage
or AC current
•Model 8206-10 provides two channels for recording of AC voltage and AC
current simultaneously
•Thermal printer-type recorder that can be used with the ease of an analog
tester
•In addition to the 9650/9651, can be used with the new Clamp On Sensor
9668 (with 1,000 A capability) for current recording.
•Use in the field on DC power.
AC/DC Voltage: 0.1 V to 500 V f.s.,
100, 200, or 500 V AC,
12 ranges
Magnified display from +25% to
Measurement
In DC mode, the zero position can be
-35% of the range.
range (1-2-5 steps)
set in steps of 20% of the range.
AC A : 10 to 1000 A (with 9668)
AC A : 10 to 1000 A (with 9668)
100 S/s (Sampling period: 10 ms)
Sampling rate
Frequency charac- V : 20 to 30 kHz, A : 20 to 20 kHz V : 30 to 30 kHz, A : 20 to 20 kHz
(depends on clamp sensor in use)
(depends on clamp sensor in use)
teristics
V : ± 2 % f.s. A : ± 3.53 % f.s.
Accuracy
(used with Clamp on sensor 9651 / option, AC 500 A range)
Recording resolution
400 points/range
20cm, 6cm/min
60cm, 20cm, 10cm,
Paper feed speed
60cm, 10cm, 2cm/hour
6cm, 2cm/hour
Recording method Amplitude 60 mm (1 div. = 10 mm), thermal printer recording
100 to 240 V AC (automatic switching), 50/60 Hz, 30 VA max.
Power supply
9.5 to 14 V DC, 30 VA max.
Dimensions and mass 250 mm (9.84 in)W × 122 mm (4.80 in)H × 93.5 mm (3.68 in)D, 1.2 kg (42.3 oz)
Carrying case 9344 ×1, Connection cord 9257 ×1, Recording paper 9235
Accessories
×1, Roll paper holder ×2, Power cord ×1, Instruction manual ×1
The Micro HiCorder 8205-10 and 8206-10 do not include clamp-on sensors for current measurement.
CLAMP ON SENSOR 9668
100 A f.s., 15 mm (0.59 in) dia, 40 Hz to
1 kHz, 3 m (9.84 ft) length
500 A f.s., 46 mm (1.81 in) dia, 40 Hz to 1000 A f.s., 55 mm (2.17 in) dia, 40 Hz to
1 kHz, 3 m (9.84 ft) length
1 kHz, 3 m (9.84 ft) length
Supplied as standard
RECORDING PAPER
9235
60 mm (1.36 in) × 15 m
(49.22 ft), 10 rolls/set
RECORDING PAPER
9236-01
Climate-resistant, 60 mm
(1.36 in) × 15 m (49.22 ft),
10 rolls/set
Accessories
CLAMP ON SENSOR 9651
Other options refer to the detailed catalog
Printer options
Dedicated options
CLAMP ON SENSOR 9650
2-ch sampling; commercial power only;
isolated input for voltage)
CARRYING CASE
9344
CONNECTION CORD
L9257
Holds optional accessories 1.2 m (3.94 ft) length
19
Recorders • Data Loggers
Portable, easy-to-use pen recorder built for the field
PEN RECORDER PR8111, PR8112
marked
Recorders
Data Loggers
PR8112 (2 pen)
•Easily portable, compact size
•Support for three power sources, can be powered with dry-cell batteries
•Outdoor-ready, ships with a drip-proof cover
•Pen-based, records data reliably
•Easy enough for anyone to use, features simple operation
Instrument does not include input cords. Input terminals are Johnson terminals and require
connection of a power supply. *Connection Cord L9257 can also be used.
■ Basic specifications (Accuracy guaranteed for 1 year)
PR8111
PR8112
1 pen
2 pens
No. of pens
Operating method Self-balancing, Disposable felt pen recording
DC voltage (Isolated input channels, isolated input and frame)
Input
Measurement ranges ±1 mV to 500 mV (9 ranges), ±1 V to 250 V (8 ranges)
250 V DC (at V range), 30 V DC (at mV range)
Max. allowable
Max. rated voltage to earth: 300 V AC, DC CAT II
input
Recording accuracy ±0.5 % of effective recording width (excluding contraction and expansion of recording paper)
150 mm (5.91 in)
Recording width
5 mm (0.20 in)
Pen interval
500 mm/s or greater (using AC adapter)
Pen speed
10 mm/min to 600 mm/min (8 ranges), 10 mm/hr to 600 mm/hr (8 ranges)
Chart speed
Accuracy: ±0.25 % (at 500 mm or higher continuous recording)
Fanfold plain paper: SE-10Z-2, length: 15 m (49.22 ft)
Recording paper
Roll plain paper: SE-10, length: 20 m (65.62 ft)
Dimensions and
mass
Fanfold, 170 mm (6.69 in)
width × 15 m (49.22 ft),
Set of 10
RECORDING PAPER
SE-10
Roll, 170 mm (6.69 in)
width × 20 m (65.62 ft),
Set of 10
50 hr (based on in-house testing condi- 25 hr (based on in-house testing conditions, use LR20 batteries)
tions, use LR20 batteries)
4 VA (AC adapter, DC power) or 3 VA (dry-cell batteries)
292 mm (11.50 in)W × 177 mm (6.97 in)
292 mm (11.50 in)W × 177 mm (6.97 in)
H × 182 mm (7.17 in)D, 3.9 kg (137.6 oz) H × 182 mm (7.17 in)D, 4.4 kg (155.2 oz)
(main unit only), 4.8 kg (169.3 oz) (with
(main unit only), 5.3 kg (186.9 oz) (with
dry-cell batteries)
dry-cell batteries)
Felt pen P-1201A (Red) ×1,
Recording paper SE-10Z-2
(fanfold) ×1, AC Adapter 9418-15
×1, Instruction manual ×1, Dripproof cover ×1
Felt pen P-1201A (Red) ×1, Felt pen
P-1202A (Green) ×1, Recording
paper SE-10Z-2 (fanfold) ×1, AC
adapter 9418-15 ×1, Instruction
manual ×1, Drip-proof cover ×1
*P-1201A is bundled with the PR8111, PR8112 *P-1202A is bundled with the PR8112
The PR8111/PR8112 uses the same recording paper and felt pens as previous HIOKI models (the EPR-3000 series and EPR-3500 series)
Pens
Recording paper
RECORDING PAPER
SE-10Z-2
adapter takes precedence)
(3) DC power supply: 10 to 27 V DC (cable available by special order)
Continuous use
time
Max. rated power
Accessories
The PR8111/PR8112 uses the same recording paper and felt pens as previous HIOKI models (the EPR-3000 series and EPR-3500 series)
(1) AC adapter 9418-15 (100 to 240 V, 50/60 Hz)
(2) D size alkaline battery (LR20) × 6 (When used with the AC adapter, the
Power supply
FELT PEN (RED) P-1201A
For the PR8111, INR-9000,
EPR-3000 series
FELT PEN (GREEN) P-1202A
FELT PEN (BLUE) P-1203A
For the PR8111, INR-9000, EPR3000 series
For the PR8111, INR-9000, EPR3000 series
Measurement support software
WAVE PROCESSOR 9335
LAN COMMUNICATOR 9333
Display, Convert, Calculate, and Print Waveforms with a PC
Remote Control via LAN Memory HiCorders and PC Communications
•Display, print, convert, and calculate on large volumes of waveform data (recorded in the Memory
HiCorder Series)
•Display waveform screens, X-Y graphs, and numerical results
•Comprehensive Search function
•Rich printing and hard copy functions to assist in
creating reports
•Save in CSV format and export to spreadsheet application (EXCEL)
•Waveform data collect function
•Remote control with the PC
•Save in CSV format and export to spreadsheet application
Supported units:
Model MR8880-20 (9335 ver1.22 or later)
Model 8861-50/8860-50 (9335 ver1.13 or later, not compatible with dual time-axis data, compatible
only to MEM, REC, and REC & MEM data recorded using single-axis sampling only),
Model 8861/8860 (9335 ver1.10 or later, not compatible with dual time-axis data, compatible only to
MEM, REC, and REC & MEM data recorded using single-axis sampling only),
Model MR8875, MR8847-01/-02/-03 (9335 ver1.23 or later)
Model 8870-20, 8855, 8847, 8842, 8841, 8840, 8835-01, 8835, 8826, 8825, 8808-01,
8807-01, 8808-51, 8807-51 (excluding harmononic analysis function)
Model MR8741/8740 (9335 Ver1.24 or later), 8731-10, 8730-10, 8720, 8715-01, 8714-01
Operating environment:
Computer running under Windows 8/7 (32/64-bit), Vista (32-bit), XP, 2000
Supported units:
Model 8826 (9333 ver.2.30 or later)
Model 8835-01*1 (9333 ver.1.10 or later, the 8835-01 High
performance model: ver.5.10 or later)
*1 Not compatible for the Model 8835
Model 8841/8842 (9333 ver.2.30 or later)
Model 8855, 8730-01, 8731-01, 8720 (9333 ver.2.00 or later)
Operating environment:
Computer running under Windows XP/2000
MEMORY HiVIEWER 9725
Perform 8860 Series functions on your PC
•Application software enables you to perform the
same data analysis on a Windows computer as on
the 8860 Series Memory Hiccorders.
•No confusion, because the screens appearing on
the computer are identical to those of the 8860
Series.
•Functions identical to those of the 8860 Series,
such as waveform processing calculation, run on
the computer.
Supported units:
8860-50, 8861-50, 8860, 8861
Operating environment:
Computer running under Windows 8/7 (32/64-bit), Vista (32-bit), XP, 2000
20
Recorders • Data Loggers
Record and Analyze CAN-Bus Signals
CAN ADAPTER 8910
marked
data from CAN-Bus)
Functions
(2) CAN-Bus signal input port settings
(3) Output channel settings (Settings to determine output channels for captured data), etc.
AC adapter (100 to 240 V AC universal), 10 to 30 V DC (Can be supplied from
a cigarette lighter socket in an automobile), Supplied from CAN-Bus signal
Power supply
input connector (10 to 30 V DC)
Dimension and mass 180 mm (7.09 in)W × 50 mm (1.97 in)H × 100 mm (3.94 in)D, 940 g (33.2 oz)
Instruction manual ×1, CD-R (including 8910 Setting Software), RS-232C cable×1,
Accessories
AC adapter 9418-15 ×1, CAN cable 9713-01×1
Logic 6 ch (24 bit)
Analog 12 ch
8826, etc.
Other analog signals: As many as there are available HiCorder channels
The 9713-01 is bundled to the 8910, the 9323 is converts large terminal of the 9323 to miniature logic terminal.
Options
•Select CAN-Bus information and convert them
into analog/logic signals to input into your
recorder or data logger
•Record both CAN adapter analog output and
actual analog data (i.e. sensor output) simultaneously
Recorders
Data Loggers
Throttle opening, rpm, speed,
water temperaCAN
ture,
etc.
Network
■ Basic specifications (Accuracy guaranteed for 1 year)
CAN-Bus interface 2-channel (Receive only)
Input
No. of output channels Up to 12 analog channels and 6 logic channels - 24 bit
Output resolution 16 bit
-5 to 5V (Analog), 0 to 5V (Logic)
Output voltage
Can follow up to a 1 ms CAN-Bus refresh rate (1 kS/s max.)
Response speed
RS-232C (For data selection settings only)
Interface
(1) Settings of CAN-Bus defined data (Various parameter settings to capture required
CONVERSION CABLE 9323
LOGIC CABLE 9714-02
Used for connecting the 9320/9321/MR9321 and the
CAN CABLE 9713-01 LOGIC CABLE 9714-01 Use to connect to Memory
9324 relay to the Memory HiCorder with small logic
Unprocessed on one end, Unprocessed on one end, HiCorder, for large logic
terminal models * This cable is not required for the
small-terminal types 9327, 9320-01, 9321-01 and
1.8 m (5.91 ft) length
1.5 m (4.92 ft) length
terminal, 1.5 m (4.92 ft) length MR9321-01.
CONNECTION CORD
9165
CONNECTION CORD
L9217
Cord has metallic BNC connectors Cord has insulated BNC
at both ends, signal output use, 1.5 connectors at both ends, signal
m (4.92 ft) length, Not CE marked output use, 1.6 m (5.25 ft) length
3 kinds of measurements with a single probe
DIFFERENTIAL PROBE 9322
■ Basic specifications (Accuracy guaranteed for 1 year)
marked
•Floating measurement of high-voltage waveforms (DC mode)
•Detection of power supply surge noise (AC mode)
•RMS rectified output (RMS mode)
•Main Applications
Measurement of potential differences included in common mode voltages,
such as IGBT
Measurement of commercial power line waveforms, such as on 400V power
lines
Measurement of high voltage surge noise waveforms
Measurement of the RMS value of inverter outputs, etc.
DC mode: Waveform monitor output, DC to 10 MHz ±3 dB
AC mode: Detection of power line surge noise, 1 kHz to 10 MHz ±3 dB
RMS mode: Rectified RMS output of DC and AC voltages, DC, 40 Hz to
100 kHz, Response speed: 200 ms or less (400 V AC)
Balanced differential input
Input type
Voltage division ratio: 1/1000, BNC terminal (DC/AC/RMS 3-mode selectable output)
Output
DC amplitude accuracy ±1 % f.s. (1000 V DC or less), ±3 % f.s. (2000 V DC or less) (f.s.=2000 V DC)
RMS amplitude accuracy ±1 % f.s. (DC, 40 Hz to 1 kHz), ±4 % f.s. (1 kHz to 100 kHz) (f.s.=1000 VAC)
H-L: 9 MΩ, approx 10 pF (C at 100 kHz)
Input resistance,
H-case, L-case: 4.5 MΩ, approx 20 pF (C at 100 kHz)
capacity
Max. allowable input 600V AC/DC (CAT III), 2000 VDC, 1000 VAC (CAT II)
Max. rated voltage When using grabber clip: 600 V AC/DC (CAT III), 1500 V AC/DC (CAT II)
When using alligator clip: 600 V AC/DC (CAT III), 1000 V AC/DC (CAT II)
to earth
1) AC adapter 9418-15 (12 V DC ±10 %) *1
2) Power supply through Power cord 9324 connected to logic terminal on
Power supply
Memory HiCorder, or other method
Measurement
functions
*1 Operating voltage range: +5 to +12 V, less than 300 mA. DC jack OD 5.5 mm (0.22 in), ID 2.1 mm (0.08 in)
Dimensions and mass 70 mm (2.76 in)W × 150 mm (5.91 in)H × 25 mm (0.98 in)D, 350 g (12.3 oz)
Alligator clips ×2, Grabber clip 9243 ×1 (Red/black each one), Carrying
Accessories
case 3853 ×1, Instruction manual ×1
How to power the 9322 with Logic
terminal on Memory HiCorder
Main unit
The Differential Probe 9322 cannot be used by itself. Please use it in combination with a Hioki
Memory HiCorder. The Differential Probe 9322 requires a power supply.
PROBE POWER UNIT 9687
Power supply
Factory-installed option - only use with the
Memory HiCorder 8860-50/8861-50, built in on
the bottom case. Simultaneously power up to 8
units of Differential Probe 9322. (Max. 3 A output)
POWER CORD 9248
Power supply to the 9322
through this cord from the
Probe power unit 9687, 70 cm
(2.30 ft) length
CONVERSION CABLE
POWER CORD 9328 POWER CORD 9324 9323
AC ADAPTER
9418-15
100 to 240V AC
Power supply to the 9322 Power supply to the
through this cord from
9322 through this cord
the MR8875, or the 8950, from large type logic
8952, 8953-10, 8955 input connector, 50 cm (1.64
units for the Memory
ft) length
HiCorder 8855, 15 cm
(0.49 ft) length
Used for connecting the
9320/9321/MR9321 and the
9324 relay to the Memory
HiCorder with small logic
terminal models * This cable
is not required for the smallterminal types 9327, 9320-01,
9321-01 and MR9321-01.
Supplied Accessories
Attaches to the tip of the Cord
L4930/9197/9322 or other, CAT
III 1000 V, 196 mm (7.72 in)
length
CARRYING CASE 3853
For the 9322/ 3661/ 3256/
3257 or other
Required Number of Simultaneous use Required
power
Maximum of the Logic Probes power cord
cord (s) connectable
Model 9322s
Number of
Maximum
connectable
Model 9322s
Max. Units
when Clamp
sensors are
also used
How to power the 9322 with
a Hioki Memory HiCorder
8860series, or 8855
[8860 series]
[8855]
Probe Power
Input unit 8950,
Unit 9687 only, 8952, 8953Use with the
10, 8955’s DC
Power Cord
jack, Use with
9248
the Power Cord
9328
MR8880-20
Power cannot be supplied from the logic
terminals
-
-
-
-
-
MR8875
Via the Power Cord 9328 connected to
DC output power terminal on Memory
HiCorder, up to 3 × 9322 (Note) Power cannot be supplied from the logic terminals
-
-
-
-
-
8870-20
Power cannot be supplied from the logic
terminals
8861-50
8861 *1
9324 +
9323
8860-50
8860 *1
9324 +
9323
8855 *1
9324 +
9323
8847 *1
MR8847-01 *2 9324 +
MR8847-02 *2 9323
MR8847-03 *2
-
-
-
-
2
9322 ×2: N/A
9322 ×1: 3
9325
6
2
9322 ×2: N/A
9322 ×1: 3
9325
6
2
9322 ×2: N/A
9322 ×1: 3
-
4 *2
9322 ×2: N/A
9322 ×1: 2
-
8
3
8*
-
8
8 *3
-
-
-
-
1
-
-
-
-
-
N/A
9325
6
4
-
-
8841 *1
8842 *1
9324
1
8835-01 *1
8835 *1
9324
1
N/A
9325
4
4
-
-
4
9322 ×4: N/A
9322 ×3: 4
9322 ×2: 6
9322 ×1: 7
9325
6
6
-
-
8826
GRABBER CLIP 9243
How to power the 9322 with F/V
Unit 8940’s sensor terminal
9324
*1 Discontinued model
*2 Not including the Logic terminals with the Logic Unit 8973, table indicates the number of 9322 that can be powered
from the main unit’s logic terminals
*3 Depends on the combination of Clamp-on probes connected to the 9687; number of connectable 9322 are different
21
Recorders • Data Loggers
MEMORY HiCORDER Common options (1/2)
*For more information about compatible models, please see product catalogs.
Recorders
Data Loggers
Voltage measurement Type A
* Input voltage is limited to the specifications of the input modules in use
* Max. rated voltage to earth is limited to the specifications of the input modules in use
CONNECTION CORD L9790
Flexible φ 4.1 mm (0.16 in) thin dia.,
cable allowing for up to 600 V input.
1.8 m (5.91 ft) length
* The end clip is sold separately.
ALLIGATOR CLIP L9790-01
CONTACT PIN 9790-03
GRABBER CLIP 9790-02
Red/black set attaches to the ends
of the cables L9790
Red/black set attaches to the ends
of the cables L9790
Red/black set attaches to the ends of the cables
L9790
* When this clip is attached to the end of the
L9790, input is limited to 300 V. Red/black set.
CONNECTION CORD L9198
φ 5.0 mm (0.20 in) dia., cable allowing
for up to 300 V input. 1.7 m (5.58 ft)
length, small alligator clip
Voltage measurement Type C
Voltage measurement Type B
* Input voltage is limited to the
specifications of the input
modules in use
* Max. rated voltage to earth is
limited to the specifications of
the input modules in use
* Input voltage is limited to the specifications of the input modules in use
* Max. rated voltage to earth is limited to the specifications of the input modules in use
CONNECTION CORD 9197
φ 5.0 mm (0.20 in) dia., cable
allowing for up to 600 V input. 1.8
m (5.91 ft) length, a detachable large
alligator clips are bundled
GRABBER CLIP 9243
Attaches to the tip of the Cord
9197, Red/ Black set, 196 mm
(7.72 in) length, CAT III 1000V
Voltage measurement Type D
* Max. rated voltage to earth is limited to the specifications of the input modules in use
* For a list of compatible Memory HiCorders, please see the product catalog
10:1 PROBE 9665
100:1 PROBE 9666
Max. rated voltage to earth is same as for
input module, max. input voltage 1 kV
rms (up to 500 kHz), 1.5 m (4.92 ft) length
Max. rated voltage to earth is same as for
input module, max. input voltage 5 kV
peak (up to 1MHz), 1.5 m (4.92 ft) length
Supplied with PC Card adapter
PC CARD 2G 9830
DIFFERENTIAL PROBE 9322
For up to 2 kV DC or 1 kV AC. Use
with either AC Adapter 9418-15, or
Probe Power Unit 9687 and Power
Cord 9248.
Storage media
High voltage measurement
* Maximum input-to-ground rated voltages fall within these products’ specifications ranges (and do
not affect the connected input units)
AC ADAPTER 9418-15
For powering Differential probe 9322,
100 to 240 V AC
(2 GB capacity)
PC CARD 1G 9729
PC Card Precaution
(1 GB capacity)
Use only PC Cards sold by HIOKI.
Compatibility and performance
are not guaranteed for PC cards
made by other manufacturers. You
may be unable to read from or save
data to such cards.
PC CARD 512M 9728
(512 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
*The large terminal-type 9320 and MR9321 can be connected to the discontinued 8804 and 8805 as well as the 8815/8830 series, 8825, 8840, 8841, 8842, 8845, 8846, 8851, 8853, 8826, and 8835-01.
*The miniature terminal type can be used with the 8807/8808 series, MR8847-01 to -03, 8847, 8855, 8860-50, 8861-50, 8870-20, MR8875, MR8880-20, etc.
Logic measurement
LOGIC PROBE 9320-01
LOGIC PROBE 9320
LOGIC PROBE MR9321-01
4-channel type, for voltage/contact
signal ON/OFF detection (response
pulse width 500 ns or more,
miniature terminal type)
4-channel type, for voltage/contact
signal ON/OFF detection (response
pulse width 500 ns or more, large
terminal type)
4 isolated channels, ON/OFF detection 4 isolated channels, ON/OFF detection 4-channel type, for voltage/contact
of AC/DC voltage (miniature terminal of AC/DC voltage (large terminal
signal ON/OFF detection (response
type)
type)
pulse width 100 ns or more, miniature
terminal type)
PC Communication
LAN CABLE 9642
Straight Ethernet cable, supplied
with straight to cross conversion
adapter, 5 m (16.41 ft) length
Note: Supports 886050/8860, 8861-50/8861
series MEM, REC and
REC&MEM data recorded
using single-axis sampling
only.
WAVE PROCESSOR 9335
Convert data, print and display
waveforms. Windows 8/7 (32-bit/64-bit),
Windows Vista (32-bit), XP, 2000
LOGIC PROBE MR9321
LOGIC PROBE 9327
CONVERSION CABLE 9323
Used for connecting the 9320/9321/MR9321
and the 9324 relay to the Memory HiCorder
with small logic terminal models
* This cable is not required for the
small-terminal types 9327, 9320-01,
9321-01 and MR9321-01.
Product Company:
Weisang GmbH (Germany)
Contact:
Email: [email protected]
URL: http://www.weisang.com/
FlexPro
FlexPro is a powerful data analysis and
presentation software for importing
and organizing data from the 8860-50,
8861-50 series.
Carrying cases
CARRYING CASE C1004
CARRYING CASE C1003
For the MR8875, includes
For the MR8880-20, includes
compartment for options, hard trunk compartment for options, soft case
type
type
22
CARRYING CASE 9783
CARRYING CASE 9782
For the 8870-20, includes
For the MR8847s, includes
compartment for options, hard trunk compartment for options, resin
coated
type
CARRYING CASE 9723
CARRYING CASE 9724
For the 8860-50/8860, hard
trunk type
For the 8861-50/8861, hard
trunk type
Recorders • Data Loggers
MEMORY HiCORDER Common options (2/2)
*For more information about compatible models, please see product catalogs.
UNIVERSAL CLAMP ON CT
9279
UNIVERSAL CLAMP ON CT
9278
600 Vrms insulated wire, 500 A AC/DC CAT II 600 Vrms, CAT III 300 Vrms,
rated current, DC to 20 kHz response, φ 200 A AC/DC rated current, DC to 100
40 mm (1.57 in) core dia., 3 m (9.84 ft)
kHz response, φ 20 mm (0.79 in) core
cord length, Not CE marked
dia., 3 m (9.84 ft) cord length
UNIVERSAL CLAMP ON CT
9277
CAT II 600 Vrms, CAT III 300 Vrms,
20 A AC/DC rated current, DC to 100
kHz response, φ 20 mm (0.79 in) core
dia., 3 m (9.84 ft) cord length
To connect Current Sensor to the 8940,
0.2 m (7.87 inch) length Caution!
Cannot be used in combination with the
CT6862
*Use with the Conversion Cable 9318
to connect Model 9272-10 to the F/V
Unit 8940.
CLAMP ON SENSOR 9272-10
3273-50
CAT III 600 Vrms, 20 A/200 A
CONVERSION CABLE 9318
CONVERSION CABLE 9319
AC rated current, 1 Hz to 100 kHz
The 9270 to 9272s, 9277 to 9279s
response, φ 46 mm (1.81 in) core dia., connects to the 8971/40/51, 38 cm (14.96 To connect the 3273-50 and the 8940,
Note: cannot be used with the 3274, 3275, 3276
3 m (9.84 ft) cord length
in) length
to connect the 8940 via this cable 9319
SENSOR UNIT 9555-10
Power supply for the Current Sensor,
used alone
CLAMP ON PROBE 3273-50
Recorders
Data Loggers
Current measurement Type A
Only the Memory HiCorder 8826, 8835-01, 8860-50, and 8861-50 are supported (DC to 100 kHz bandwidth class).
*Connect directly to the F/V unit 8940 with a conversion cable or use with the 9555-10. *The 3274/3275/3276 cannot be used with the F/V unit 8940.
CONVERSION CABLE 9705
DC to 50 MHz wideband response, mA-class
current up to 30 Arms
Only the Memory HiCorder MR8874-01s and 8847 are supported (DC to 100 kHz bandwidth class).
*Connect directly to the Current unit 8971 with a conversion cable or use with the 9555-10. *The 3273/3274/3275/3276 cannot be used with the Current unit 8971.
CURRENT UNIT 8971
Current measurement Type B
AC/DC CURRENT SENSOR 9709
CAT III 1000 V, 500 A AC/DC rated
current, DC to 100 kHz response, φ 36
mm (1.42 in) core dia., 3 m (9.84 ft) cord
length
AC/DC CURRENT SENSOR
CT6863
AC/DC CURRENT SENSOR
CT6862
CAT III 1000 V, 200 A AC/DC rated
current, DC to 500 kHz response, φ 24
mm (0.94 in) core dia., 3 m (9.84 ft) cord
length
CAT III 1000 V, 50 A AC/DC rated
current, DC to 1 MHz response, φ 24
mm (0.94 in) core dia., 3 m (9.84 ft) cord
length
UNIVERSAL CLAMP ON CT
9279
UNIVERSAL CLAMP ON CT
9278
UNIVERSAL CLAMP ON CT
9277
600 Vrms insulated wire, 500 A AC/
DC rated current, DC to 20 kHz
response, φ 40 mm (1.57 in) core dia.,
3 m (9.84 ft) cord length, Not CE
marked
CAT II 600 Vrms, CAT III 300 Vrms,
200 A AC/DC rated current, DC to
100 kHz response, φ 20 mm (0.79 in)
core dia., 3 m (9.84 ft) cord length
CAT II 600 Vrms, CAT III 300 Vrms,
20 A AC/DC rated current, DC to 100
kHz response, φ 20 mm (0.79 in) core
dia., 3 m (9.84 ft) cord length
CLAMP ON SENSOR 9272-10
CAT III 600 Vrms, 20 A/200 A AC rated
current, 1 Hz to 100 kHz response, φ 46
mm (1.81 in) core dia., 3 m (9.84 ft) cord
length
CONVERSION CABLE 9318
The 9270 to 9272s, 9277 to 9279s
connects to the 8971/40/51, 38 cm
(14.96 in) length
*The 9318 is bundled
with the 8971
SENSOR UNIT 9555-10
CONNECTION CORD L9217
CONNECTION CORD 9165
Power supply for the Current Sensor,
used alone
Cord has insulated BNC connectors
at both ends, signal output use, 1.6 m
(5.25 ft) length
Cord has metallic BNC
connectors at both ends, use at
metallic terminal, 1.5 m (4.92 ft)
length, Not CE marked
*Connect to an ANALOG UNIT (DC to 100 MHz bandwidth class)
Current measurement Type C
CLAMP ON PROBE 3276
CLAMP ON PROBE 3275
CLAMP ON PROBE 3274
CLAMP ON PROBE 3273-50
DC to 100 MHz wide band response,
mA-class current up to 30 Arms
DC to 2 MHz wide band response,
mA-class current up to 500 Arms
DC to 10 MHz wide band response,
mA-class current up to 150 Arms
DC to 50 MHz wide band response,
mA-class current up to 30 Arms
POWER SUPPLY 3272
POWER SUPPLY 3269
Single sensor connectable
Connect up to four sensors
CLAMP ON AC/DC
SENSOR CT9691-90
CLAMP ON AC/DC
SENSOR CT9692-90
CLAMP ON AC/DC
SENSOR CT9693-90
DC to 10kHz (-3dB), 100A,
DC to 20kHz (-3dB), 200A,
DC to 15kHz (-3dB), 2000A,
Output 0.1 V/f.s., Cord length Output 0.2 V/f.s., Cord length Output 0.2 V/f.s., Cord length
2 m (6.56 ft)
2 m (6.56 ft)
2 m (6.56 ft)
Current measurement
Current measurement Type D
*Connect to the ANALOG UNIT (DC to 20 kHz bandwidth class)
Clamp sensor sold separately
CLAMP ON AC/DC HiTESTER 3290
Enables observation of AC/DC current
waveforms. Input range and frequency range
depend on clamp sensor used, 2V AC output
Current measurement Type E
*Connect to the ANALOG UNIT (DC to 20 kHz bandwidth class) (3283: Cannot be used with DC current.)
* 9445-02/-03 powering the 3283, 3284, 3285, or 3290
CLAMP ON LEAK
HiTESTER 3283
10mA range/ 10μA
resolution to 200A range,
monitor / analog output
1V f.s.
CLAMP ON AC/DC
HiTESTER 3284
CLAMP ON AC/DC
HiTESTER 3285
20A, 200A AC/DC
ranges, monitor / analog
output 1V f.s.
200A, 2000A AC/DC
ranges, monitor / analog
output 1V f.s.
AC ADAPTER 9445-02
For USA model, 100 to 240 V
AC, 9V/ 1A
OUTPUT CORD 9094 CONVERSION ADAPTER
3.5 mm (0.14in) dia. mini 9199
plug to banana, 1.5m
(4.92ft) length, Not CE
markde
AC ADAPTER 9445-03
For EU model, 100 to 240 V
AC, 9V/ 1A
Female banana terminals to BNC Note: With the Memory HiCorder
plug (output), use to connect to
connection requires Output cord 9094 and
BNC terminal on Input Module Conversion adapter 9199.
Current measurement Type F
*For commercial power lines, 50/60Hz (separate power supply not required)
CLAMP ON PROBE 9018-50
CLAMP ON PROBE 9132-50
Enables observation of AC current
waveforms. 40 Hz to 3 kHz
response, input 10 A to 500 A
range, output 0.2 V AC/range
Enables observation of AC current
waveforms. 40 Hz to 1 kHz
response, input 20 A to 1000 A
range, output 0.2 V AC/range
23
Recorders • Data Loggers
Featuring USB flash drive support and improved accuracy! Your Personal 10-channel Logger
MEMORY HiLOGGER LR8431-20
■ Basic specifications (Accuracy guaranteed for 1 year)
Analog: 10 isolated channels using scanning input method (M3 mm dia. screw terminal block)
Pulse: 4 channels (All pulse inputs share common ground with the main unit)
Voltage : ±100 mV to ±60 V, 1-5V f.s. 6 ranges, Max. resolution 5µV
Temperature (thermocouples) : −200 ˚C to 1800 ˚C (depend on the sensor), 1 range
(K, J, E, T, N, R, S, B), Max. resolution 0.1 ˚C
Temperature (Pt 100 sensor) : not available
Measurement
Humidity : not available
parameters
Totalized pulses : 0 to 1000M pulse, 1 range (No-voltage ‘a’ contact, open collector
or voltage input), Max. resolution 1 pulse
Rotation count : 0 to 5000/n (r/s) f.s. 1 range (No-voltage ‘a’ contact, open collector
or voltage input), Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000)
Max. allowable input DC 60 V (Analog input), DC -5 V to 10 V (Pulse input)
Max. rated voltage to AC 30 Vrms, DC 60 V (Upper limit voltage that does not cause damage when applied
between input channel and chassis, and between each input channels)
earth
10 ms to 1 hour, 19 selections (All input channels are scanned at high speed during
Recording intervals
every recording interval)
Number of channels
Recorders
Data Loggers
marked
•Record measurement data on a USB flash drive for easy transfer to a computer
•Record to reliable Compact Flash cards during long-term measurement applications for increased peace of mind
•Replace storage media during real-time recording
•Improved thermocouple measurement accuracy and reference junction compensation accuracy
•Ten isolated analog input channels
•10 ms sampling and recording across all channels
•Noise-resistant measurement circuitry for improved readings
•Ultra-compact for convenient portability
•Widescreen, bright LCD gives excellent viewability
Note: The LR8431-20 is not bundled with the Battery Pack 9780. Thermocouples are not provided by HIOKI,
and must be purchased from a separate vendor.
Note: Use only HIOKI CF cards, which are manufactured to strict industrial standards, for long-term storage
of important data. Correct operation of non-HIOKI CF cards or USB memory sticks is not guaranteed
Selectable Filters
Memory capacity
External Interface
Display
Functions
Power supply
50 Hz, 60 Hz, or OFF (digital filtering of high frequencies on analog channels)
Internal storage: 3.5 M-words, External storage: CF card or USB memory stick
(only the HIOKI CF card is guaranteed for correct operation)
USB 2.0 mini-B receptacle ×1; Functions: Control from a PC, Transfers files from the
installed CF card to a PC (cannot transfer files from the connected USB memory stick to a PC
via USB communication), Data copy between CF card and USB memory stick
4.3-inch WQVGA-TFT color LCD (480 × 272 dots)
Save data to the CF Card or USB memory stick in real time, Numerical
Calculations, etc.
AC adapter Z1005: 100 to 240 VAC (50/60 Hz)
Battery pack 9780: Continuous use 2.5 hours
12 V DC supply: 10 to 16 V (please contact HIOKI distributor for cable; less than 3
m/9.84 ft cable length)
Dimensions and
mass
176 mm (6.93 in) W × 101 mm (3.98 in) H × 41 mm (1.61 in) D, 550 g (19.4 oz)
Accessories
Measurement Guide ×1, CD-R (Instruction manual PDF, Logger Utility Instruction
Manual PDF, Data acquisition application program Logger Utility) ×1, USB cable ×1,
AC adapter Z1005 ×1
(Battery pack 9780 not installed)
Other options refer to the detailed catalog
SOFT CASE 9812
NiMH, Charges while installed
in the main unit
CARRYING CASE 9782
CONNECTION CABLE 9641
Includes space for small items, Includes compartment for options, For pulse inputs, 1.5 m (4.92 ft) length
Neoprene rubber
Resin coated
Storage media
Options
BATTERY PACK 9780
Supplied with PC
Card adapter
PC CARD 2G 9830
(2 GB capacity)
PC CARD 1G 9729
(1 GB capacity)
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance are not
guaranteed for PC cards made by other
manufacturers. You may be unable to
read from or save data to such cards.
PC CARD 512M 9728
(512 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
Fast 10-ms Sampling. Up to 600 Channels of Data Logging
MEMORY HiLOGGER 8423
■ Basic specifications (Accuracy guaranteed for 1 year)
No. of connectable
units
Maximum 8 units (total 120 channels), Bundle 8 Modules together to achieve a
120-channel System, Bundle 5 Systems together to enable a maximum of 600 channels
of simultaneous recording
Measurement parameters
Model 8948
Voltage: ±150mV to ±100V, 1-5V f.s. 6 ranges, Max. resolution 5µV
Temperature (thermocouples): −200˚C to 2000˚C (depend on the sensor), 3 ranges (K, E,
J, T, N, W (Wre5-26), R, S, B), Max. resolution 0.01˚C
Max. allowable input: DC 100V, Max. rated voltage between channels: 200 V DC, Max.
rated voltage to earth: 600 V DC, AC
Measurement parameters
Model 8949
Voltage: ±150mV to ±60V, 1-5V f.s. 6 range, Max. resolution 5µV
Temperature (thermocouples): −200˚C to 2000˚C (depend on the sensor), 3 ranges (K, E,
J, T, N, W (Wre5-26), R, S, B), Max. resolution 0.01˚C
Temperature (Resistance temperature sensor): −200˚C to 800˚C, 3 ranges (Pt 100, JPt
100), Max. resolution 0.01˚C
Humidity: 100% rh f.s., 5.0 to 95.0% rh (use with the 9701), resolution 0.1% rh
Max. allowable input: DC 60V, Max. rated voltage between channels : 120 V DC, Max.
rated voltage to earth : 600 V DC, AC
marked
Example: Connect up 8 measurement modules for a
120-channel system
•Capture data with 15 to a maximum of 600 channels
•Send data to the PC in real time
•Isolated to sustain up to 600 V between modules and earth
•USB 2.0, LAN 100BASE-TX, Store to 1GB PC Card
•Simultaneous fast- and low-speed sampling allows for media storage
space efficiency
Note: 8423 cannot operate alone. You must install one or more optional input modules
in the unit. Thermocouples are not provided by HIOKI, and must be purchased from a
separate vendor.
Measurement parameters
Model 8996
Recording intervals
Function
Interface
LAN: supports 100Base-TX, USB: Ver 2.0, mini-B receptacle, CF card slot
Power supply
Using the AC adapter 9418-15 /20 VA (when connected with 8 units),
12 V Battery (voltage may range from -20% to +30%, Please contact HIOKI for connection cord)
Dimensions and mass
67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only)
Quick start manual ×1, Instruction manual ×1, AC adapter 9418-15 ×1, USB cable ×1,
CD-R (data collection software “Logger Utility”) ×1, Connector cover ×1, Ferrite
clamp ×1, Connection plate ×1
Accessories
Other options refer to the detailed catalog
15-channles, Voltage,
Thermocouple input
24
Resistance temperature sensor,
Humidity measurement
DIGITAL/PULSE UNIT 8996
15-channels, ON/OFF logic signal,
Totalized pulses (integrated or
instantaneous), Rotation count
ALARM UNIT 8997 CONNECTION CABLE
15-channels, Open9683
collector output
For synchronization, cable
length 1.5 m (4.92 ft)
Storage media
Input options
VOLTAGE/TEMP UNIT UNIVERSAL UNIT 8949
15-channels, Voltage, Thermocouple,
8948
Totalized pulses: 0 to 1000M pulse, 1 range (No-voltage ‘a’ contact, open collector or
voltage input), Max. resolution 1 pulse
Rotation count: 0 to 5000/n (r/s) f.s. 1 range (No-voltage ‘a’ contact, open collector or
voltage input), Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000)
Digital input: ON/OFF digital signal
Max. allowable input: DC 50V, Max. rated voltage between channels: 33V AC, 70V DC,
Max. rated voltage to earth: 600 V DC, AC, (Upper limit voltage that does not cause
damage when applied between CH-1 to CH-5 each channel and chassis, CH-6 to
CH-10 each channel and chassis, CH-11 to CH-15 each channel and chassis, and
between each UNITs), (common ground for CH-1 to CH-5, common ground for CH-6
to CH-10, common ground for CH-11 to CH-15)
10ms to 1hr, 19 ranges (5s to 1hr when combined with humidity measurement), Dual sampling:
Recording intervals can be specified for every input module (high-speed and low-speed)
Measurement data are saved to the CF Card in real time, Trigger function, Digital filter
(Input unit), Alarm output (use with the Alarm unit 8997), Data acquisition is controlled by the PC data acquisition program, FTP server function, HTTP server function
* PC CARD 2G 9830 : cannot use
with the 8423
* Supplied with PC Card adapter
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance are not
guaranteed for PC cards made by other
manufacturers. You may be unable to
read from or save data to such cards.
PC CARD 1G 9729
(1 GB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
Recorders • Data Loggers
Logging Multi-point Data Has Never Been So Easy with a Wireless Logger
WIRELESS LOGGING STATION LR8410-20
■ LR8410-20 Basic specifications (Accuracy guaranteed for 1 year)
(*2) Setting not available when the thermocouple burnout detection setting is on
LR8511
Data storage
marked
Interface
Display device
LR8410-20
Functions
LR8510
• Download data using Bluetooth® wireless technology
• Install logging modules in hard-to-reach locations (over line-of-sight
distances of up to 30 meters ( *1) )
( *1) The presence of obstructions may shorten this range
• Logging station controls up to seven logging modules, allowing you
to collect 105 channels of data
• 100 msec simultaneous sampling across all channels (rapid scanning
method)
• Two types of logging modules measure voltage, temperature, resistance, and humidity
• Quick Set guide makes configuration a breeze
LR8410-20 (Main unit with LCD screen)
LR8510 (Input module)
LR8511 (Input module)
The LR8410-20 alone is not capable of making measurements. One or more input
modules are necessary to measure. The main unit and input modules are not bundled
with the Battery Pack Z1007. Thermocouples are not provided by HIOKI, and must be
purchased from a separate vendor.
Note: Use only HIOKI SD Memory card, which is manufactured to strict industrial
standards, for long-term storage of important data. Correct operation of non-HIOKI
SD cards or USB memory sticks are not guaranteed.
Countries and regions where wireless operation is currently supported: Japan, U.S.A., Canada, EU, Norway, Switzerland, Turkey, Singapore (labeled products only)
These products emit radio waves. Use of radio waves is subject to licensing requirements in
certain countries. Use in countries or regions other than those listed above may constitute a
violation of law, exposing the operator to legal penalties.
Bluetooth® is a trademark of Bluetooth SIG, Inc. and licensed for use by HIOKI E.E. CORPORATION.
Power supply
Internal memory: 8 M-words, Data storage media: SD memory card or USB memory stick (Only data recorded to a genuine HIOKI SD memory card is guaranteed)
LAN: 100BASE-TX, Functions: Data acquisition using bundled software or PC
commands, FTP server, FTP client, HTTP server function, or E-mail system
USB: USB 2.0 series mini-B receptacle ×1, Functions: Data acquisition using
bundled software or PC commands, Transfer data from the SD memory card to a
PC via USB drive mode
5.7 inch TFT color liquid crystal display (640 × 480 pixel)
Save waveform data in real time to the SD memory card or USB memory stick, Numerical value calculations, Waveform calculations, 4ch alarm output (not isolated,
common ground), and others
[AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 45 VA
Max. (including AC adapter), 15 VA Max. (exclusive of AC adapter)
[Internal battery] Using the Battery pack Z1007 (optional accessory), 3 hours of
continuous use (at 23 ˚C reference data), 7 VA Max.
[External power] 10 to 28 V DC, 15 VA Max. (Please contact your HIOKI distributor
Recorders
Data Loggers
Max. 105 ch (use 7 units of LR8510 or LR8511)
No. of measurement One or more LR8510 or LR8511 measurement modules are required. Main unit can control up
channels
to 7 modules with Bluetooth® wireless technology, mix and match modules as needed
Pulse, Digital input [Pulse totalization] [Rotation count] Not available
100 ms(*2), 200 ms to 1 hour, 16 selections (All input channels are scanned at high speed
Recording intervals
during every recording interval)
for connection cord)
Dimensions and mass 230 mm (9.06 in) W × 125 mm (4.92 in) H × 36 mm (1.42 in) D, 700 g (24.7 oz) (excluding Battery pack)
Instruction manual ×1, Measurement guide ×1, SD Memory Card (2GB) Z4001 ×1,
Accessories
CD-R (data collection software “Logger Utility”) ×1, USB cable ×1, AC Adapter Z1008 ×1
■ LR8510 Basic specifications (Accuracy guaranteed for 1 year)
[No. of channels] 15 analog channels; isolated scanning method input (2 terminals: M3
screw type)
[Voltage] ±10 mV to ±100 V, 1-5 V f.s. Max. resolution: 500 nV (Isolated between channels)
[Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor), Thermocouples (K,
J, E, T, N, R, S, B, W), Max. resolution 0.01 ˚C (Isolated between channels)
Measurement
[Pt 100, JPt 100 sensor] [Resistance] [Humidity] Not available
parameters
[Max. rated voltage between isolated input channels] 300 V DC
[Max. allowable input] ±100 V DC
[Max. rated voltage from isolated terminals to ground] 300 V AC, DC
Caution: Max. voltage from terminals to ground without damage
[Digital filter] Select from OFF/ 50 Hz/ 60 Hz (the cut-off frequency is automatically set)
Control and commu- Bluetooth® 2.1 + EDR (between Wireless Logging Station LR8410-20 and input modules);
communication range: 30 m (line of sight), SSP security
nications
[AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 23 VA Max.
(including AC adapter), 7 VA Max. (exclusive of AC adapter)
[Internal battery] Using the Battery pack Z1007 (optional accessory), 24 hours of continuPower supply
ous use (at 100 ms recording interval, 23 ˚C reference data), 120 hours of continuous use (at 1
minute recording interval, 23 ˚C reference data), 0.4 VA Max.
[External power] 10 to 28 V DC, 7 VA Max.
Dimensions and mass 150 mm (5.91 in) W × 90 mm (3.54 in) H × 56 mm (2.20 in) D, 340 g (12.0 oz) (excluding Battery pack)
Instruction manual ×1, AC Adapter Z1008 ×1, Bracket ×1
Accessories
■ LR8511 Basic specifications (Accuracy guaranteed for 1 year)
[No. of channels] 15 analog channels; isolated scanning method input (4 terminals: pushbutton type)
[Voltage] ±10 mV to ±100 V, 1-5 V f.s. Max. resolution: 500 nV, (Isolated between channels)
[Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor), Thermocouples (K,
J, E, T, N, R, S, B, W), Max. resolution 0.01 ˚C, (Isolated between channels)
[Temperature: Pt 100, JPt 100 sensor] -200 ˚C to 800 ˚C, Max. resolution 0.01 ˚C, (Not
Measurement
parameters
isolated between channels)
[Resistance] 0 Ω to 200 Ω f.s. Max. resolution 0.5 mΩ, (Not isolated between channels)
[Humidity] 5.0 to 95.0 % rh (use with optional sensor), resolution 0.1 % rh, (Not isolated
between channels)
[Max. rated voltage between isolated input channels] 300 V DC
[Max. allowable input] ±100 V DC
[Max. rated voltage from isolated terminals to ground] 300 V AC, DC
Caution: Max. voltage from terminals to ground without damage
[Digital filter] Select from OFF/ 50 Hz/ 60 Hz (the cut-off frequency is automatically set)
Control and commu- Bluetooth® 2.1 + EDR (between Wireless Logging Station LR8410-20 and input modules);
communication range: 30 m (line of sight), SSP security
nications
[AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 23 VA Max.
(including AC adapter), 7 VA Max. (exclusive of AC adapter)
[Internal battery] Using the Battery pack Z1007 (optional accessory), 24 hours of continuPower supply
ous use (at 100 ms recording interval, 23 ˚C reference data), 120 hours of continuous use (at 1
minute recording interval, 23 ˚C reference data), 0.6 VA Max.
[External power] 10 to 28 V DC, 7 VA Max.
Dimensions and mass 150 mm (5.91 in) W × 90 mm (3.54 in) H × 56 mm (2.20 in) D, 320 g (11.3 oz) (excluding Battery pack)
Instruction manual ×1, AC Adapter Z1008 ×1, Bracket ×1
Accessories
*Z4001 is bundled with the LR8410-20
2 terminals M-3 mm screw type, 15 channels, Voltage, Temperature with thermocouple, for the LR8410-20
WIRELESS UNIVERSAL UNIT LR8511
4 terminals push-button type, 15 channels,
Voltage, Temperature with thermocouple, Platinum
Resistance temperature sensor, Humidity, or
Resistance measurement, for the LR8410-20
AC ADAPTER Z1008
Li-ion, Charges while installed
100 to 240V AC
HUMIDITY SENSOR
Z2000
3 m (9.84 ft) length, for the
LR8410-20, LR8400-20
series
CARRYING CASE
C1007
Holds one LR8410-20 and four
measurement units
SD MEMORY
CARD 2GB Z4001
For storing measurement
data
FIXED STAND Z1009
For wall hanging and slanted
bench mounting
PC communication
Power supply
BATTERY PACK Z1007
Carrying cases and stands
*AC adapter is bundled with the LR8410-20, LR8510/8511
Storage media
Input options
WIRELESS VOLTAGE/TEMP
UNIT LR8510
SD Card Precaution
Use only the SD Card Z4001 sold
by HIOKI. Compatibility and performance are not guaranteed for
SD cards made by other manufacturers. You may be unable to read
from or save data to such cards.
LAN CABLE 9642
Straight-through cable
with crossover cable, 5 m
(16.41 ft) length
25
Recorders • Data Loggers
Portable Data Logger with 30 Standard Channels, Expandible to 60 Channels
MEMORY HiLOGGER LR8400-20 series
Recorders
Data Loggers
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
[No. of channels] 15 analog channels; isolated scanning method input (4 terminals:
push-button type)
[Voltage] ±10 mV to ±100 V, 1-5 V f.s. Max. resolution: 500 nV, (Isolated between
Analog input
channels and from each channel to chassis)
Universal unit
[Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor),
Thermocouples (K, J, E, T, N, R, S, B, W,) Max. resolution 0.01 ˚C, (Isolated
LR8501
Actual functionality between channels and from each channel to chassis)
will depend on
[Temperature: Pt 100, JPt 100 sensor] -200 ˚C to 800 ˚C, Max. resolution 0.01 ˚C, (Not
combination of units isolated between channels)
installed
[Resistance] 0 Ω to 200 Ω f.s. Max. resolution 0.5 mΩ, (Not isolated between channels)
Note: Isolated from
[Humidity]
5.0 to 95.0 % rh (use with optional sensor), resolution 0.1 % rh, (Not isoeach channel to
lated between channels nor from each channel to chassis)
chassis
[Max. rated voltage between isolated input channels] 300 V DC
[Max. allowable input] ±100 V DC
[Max. rated voltage from isolated terminals to ground] 300 V AC, DC
[No. of channels] 15 analog channels; isolated scanning method input (2 terminals:
M3 screw type)
Analog input
[Voltage] ±10 mV to ±100 V, 1-5 V f.s. Max. resolution: 500 nV, (Isolated between
Votage/temp unit channels and from each channel to chassies)
LR8500
[Temperature: Thermocouples] -200 ˚C to 2000 ˚C (depends on sensor),
Actual functionality Thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01 ˚C, (Isolated
will depend on
between channels and from each channel to chassies)
combination of units [Pt 100, JPt 100 sensor] [Resistance] Not available
installed
[Humidity] 5.0 to 95.0 % rh (use with optional sensor), resolution 0.1 % rh, (Not isolated between channels nor from each channel to chassies)
Note: Isolated from [Max. rated voltage between isolated input channels] 250 V DC
each channel to
[Max. allowable input] ±100 V DC
chassis
[Max. rated voltage from isolated terminals to ground] 300 V AC, DC
Caution: Max. voltage from terminals to ground without damage
•Compact size despite 30-channel standard capabilities
•Expand up to 30 additional channels
•Protected against unexpected power outages
•Write data to USB memory stick or CF card in real-time
•Built in with USB 2.0 or 100 BASE-TX LAN interfaces
•5.7" TFT color display
• LR8400-20 (with built-in Votage/temp unit× 2)
Built-in units are equivalent to the Votage/temp unit LR8500 (15 ch) × 2
• LR8401-20 (with built-in Universal unit × 2)
Built-in units are equivalent to the Universal unit LR8501 (15 ch) × 2
• LR8402-20 (with built-in Universal unit × 1, Votage/temp unit × 1)
Built-in units are equivalent to the Universal unit LR8501 (15 ch) × 1, and Votage/temp
unit LR8500 (15 ch) × 1
Pulse, Digital
input
Recording
intervals
Note: Built-in units cannot be removed or changed
[No. of channels] 8 channels, pulse / digital selectable for each channel, M3
screw terminal, not isolated, common ground
[Pulse totalization] 0 to 1000 M pulse, 1 range (No-voltage 'a' contact; normally
open, open collector or voltage input), Max. resolution 1 pulse
[Rotation count] 0 to 5000 /n (r/s) f.s. 1 range (same as Pulse totalization input
signal condition), resolution 1/n (r/s) Note: "n" is the number of sensor output
pulses per revolution, 1 to 1000
[Digital input] Record logical "1" or "0" at each sampling
[Max. rated voltage between input channels] Not isolated
[Max. allowable input] 0 to 50 V
10 ms to 50 ms, 100 ms to 1 hour, 19 selections (All input channels are scanned at
high speed during every recording interval)
Note: limited by using channels at 10 ms to 50 ms interval
Digital filter
Select from OFF/ 50 Hz/ 60 Hz (the cut-off frequency is automatically set)
Data storage
Internal memory: 8 M-words, Data storage media: CF card or USB memory
LAN interfaces
USB interfaces
(Only data recorded to a genuine HIOKI CF card is guaranteed)
100BASE-TX, Functions: Data acquisition using bundled software or PC commands, FTP server, FTP client, HTTP server function, or E-mail system
Note: LAN communication support planned from software Ver. 1.20
USB 2.0 High-speed capable, series mini-B receptacle
Functions: Data acquisition using bundled software or PC commands, Transfer
data from the CF card to a PC via USB drive mode
Note: Data transfer not possible from USB memory sticks
Add input channels!
Display device
5.7 inch TFT color liquid crystal display (640 × 480 pixel)
Save waveform data in real time to the CF card or USB memory stick,
Numerical value calculations, Waveform calculations, and others
AC Power supply Using the AC adapter 9418-15 (100 to 240 V AC, 50/60 Hz), 7 VA
Using the Battery pack Z1000 (optional accessory), Continuous use 5 hr,
DC Power supply External power: 10 to 28 V DC (Please contact your HIOKI distributor for connecOther functions
tion cord)
Dimensions and
Mass
After connecting 1 measurement unit to
the LR8402-20 (example 45-ch system)
After connecting 2 measurement units to
the LR8402-20 (example 60-ch system)
Accessories
272 mm (10.71 in) W × 182.4 mm (7.18 in) H × 66.5 mm (2.62 in) D,
1.8 kg (63.5 oz), (LR8400-20 main unit, excluding the Battery Pack 370 g/ 13.1 oz)
Instruction manual ×1, Measurement guide ×1, CD-R (data collection software
"Logger Utility") ×1, USB cable ×1, AC adapter 9418-15 ×1
Supplied with PC
Card adapter
UNIVERSAL UNIT LR8501
2 terminals M-3 mm screw type, 15 channels, Voltage, Temperature with thermocouple, or Humidity measurement, for the
LR8400-20 series
4 terminals push-button type, 15 channels,
Voltage, Temperature with thermocouple, Platinum
Resistance temperature sensor, Humidity, or
Resistance measurement, for the LR8400-20 series
NiMH, Charges while installed in AC ADAPTER 9418-15
the main unit
100 to 240V AC
CARRYING CASE
C1000
Includes compartment for
options
(2 GB capacity)
PC CARD 1G 9729
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance are not
guaranteed for PC cards made by other
manufacturers. You may be unable to
read from or save data to such cards.
FIXED STAND Z5000
For wall hanging and slanted
bench mounting
PC communication
Power supply
26
BATTERY PACK Z1000
Carrying cases and stands
*AC adapter is bundled with the LR8400-20 series
3 m (9.84 ft) length, for the
LR8410-20, LR8400-20
series
Storage media
Input options
VOLTAGE/TEMP UNIT LR8500
HUMIDITY SENSOR
Z2000
PC CARD 2G 9830
(1 GB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
LAN CABLE 9642
Straight-through cable
with crossover cable, 5 m
(16.41 ft) length
Recorders • Data Loggers
Verify the Correct Power Level to Solve Power Loss Problems
PV POWER VERIFIER LR8400-92, LR8400-93
■ PV mode basic specifications (Accuracy guaranteed for 1 year)
Input
[unit1-ch1] Voltage measurement mode, 1 V f.s., 1,000 V conversion ratio
[unit1-ch2] Current measurement mode, 1 V f.s., 1,000 A conversion ratio
(Fixed channels)
[unit1-ch3] Insolation measurement mode, 20 mV f.s., 140 kW/m2 conversion ratio
(Automatic setting
[unit1-ch4] Panel temperature measurement mode, K thermocouple 100°C f.s., 1°C
of conversion ratio)
conversion ratio
marked
(Fixed channels)
(Automatic setting
of equation)
[W1] Power (kW) = Voltage (Ch. 1-1) × current (Ch. 1-2)
[W2] Power integration (kWh) = Voltage (Ch. 1-1) × current (Ch. 1-2) × measurement
time (h)
[W3] Estimated power (kW) = Insolation strength (Ch. 1-3) / Gs (standard test condition of 1 kW/m2) × (1 + temperature loss*1) × (1 - coefficient for other losses) × photovoltaic cell rated output (kW)
[W4] Estimated integration (kWh) = Insolation strength (Ch. 1-3) / Gs (standard test
condition of 1 kW/m2) × (1 + temperature loss*1) × (1 - coefficient for other losses) ×
photovoltaic cell rated output (kW) × measurement time (h)
*1 Temperature loss = Photovoltaic cell maximum output temperature coefficient ×
(panel temperature (Ch. 1-4) - 25) / 100
[W5] AC estimated power (kW) = Estimated power (w3) × power conditioner conversion efficiency (reference value)
[W6] AC estimated integration (kWh) = Estimated energy (w4) × power conditioner
conversion efficiency (reference value)
[W7] Estimated power approximation rate (%) = Energy (w2) / estimated energy (w4)
Display
PV Wave + Value, PV Wave + Crsr, Gauge + PV Wave, PV Value,
Estimate Power, AC Estimate (reference values)
Other specifications
Functionality is identical to that of the LR8400-20 when PV mode is OFF.
Equations
•Estimate expected electricity production (estimated electrical energy)
•Estimate the expected electricity production at the current time under continuously varying conditions of air temperature and insolation
•Compare the estimate with actual electricity production
•Production can be measured without shutting off the circuit
•Measure production trend
•Investigate module failures by identifying strings with wiring breaks and using
the instrument in conjunction with a masking shield
•Add up to 7 more channels of clamp or temperature measurements even in PV mode
•When PV mode is turned OFF, the instrument can also be used as a 30-channel
data logger
•When PV mode is turned OFF, optional input units can be added to expand the
instrument to a maximum of 60 channels
Recorders
Data Loggers
[unit1-ch5] to [unit1-ch11] Select and add as voltage, thermocouple, or clamp (2,000 A,
Expansion chan- 200 A, 100 A, 20 A, 10 A).
*[unit1-ch12] to [unit1-ch15] and [unit2-ch1] to [unit2-ch15] cannot be used in PV
nel settings
mode.
PV Power Verifier LR8400-92 (200A AC/DC Sensor and other bundled accessories)
Differential Probe 9322
Memory HiLogger
LR8400-23 (PV Edition)
Clamp On AC/DC Sensor
CT9692-90
9804-01 (Red)
Magnetic Adapter
9804-02 (Black)
Option Parts Set (Bundled)
• Pyranometer
(Manufactured by EKO INSTRUMENTS for LR8400-92/ -93)
• Thermocouple (20m)
• Power Cord (for Differential Probes)
• BNC Conversion Cable x 2
(for Clamp Sensors and Differential Probes)
• Magnetic Sheet
PV Power Verifier LR8400-93 (2000A AC/DC Sensor and other bundled accessories)
Differential Probe 9322
Memory HiLogger
LR8400-23 (PV Edition)
Clamp On AC/DC Sensor
CT9693-90
NiMH, Charges while installed in AC ADAPTER 9418-15
the main unit
100 to 240V AC
PC communication
Power supply
BATTERY PACK Z1000
Carrying cases and stands
*AC adapter is bundled with the LR8400-92, LR8400-93
9804-01 (Red)
Magnetic Adapter
9804-02 (Black)
Option Parts Set (Bundled)
• Pyranometer
(Manufactured by EKO INSTRUMENTS for LR8400-92/ -93)
• Thermocouple (20m)
• Power Cord (for Differential Probes)
• BNC Conversion Cable x 2
(for Clamp Sensors and Differential Probes)
• Magnetic Sheet
CARRYING CASE
C1000
Includes compartment for
options
LAN CABLE 9642
Straight-through cable
with crossover cable, 5 m
(16.41 ft) length
CLAMP ON AC/DC SENSOR
CT9691-90
CLAMP ON AC/DC SENSOR
CT9692-90
CLAMP ON AC/DC SENSOR
CT9693-90
DC to 10kHz (-3dB), 100A, Output 0.1 V/f.s.
DC to 20kHz (-3dB), 200A, Output 0.2 V/f.s.
DC to 15kHz (-3dB), 2000A, Output 0.2 V/f.s.
Storage media
Current measurement
Supplied with PC
Card adapter
PC CARD 2G 9830
(2 GB capacity)
PC CARD 1G 9729
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance are not
guaranteed for PC cards made by other
manufacturers. You may be unable to
read from or save data to such cards.
(1 GB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
27
Recorders • Data Loggers
Complete Line of Easy-to-Use Compact Loggers with Expanded Memory
LR5000 Series
Analysis of measurement data on a PC requires the optional Communication Adapter LR5091 or Data Collector LR5092-20.
Temperature or Humidity measurement
HUMIDITY LOGGER LR5001
Model
Instrumentation Measurement AC Current Measurement DC Voltage Measurement
TEMPERATURE LOGGER LR5011
INSTRUMENTATION LOGGER LR5031
CLAMP LOGGER LR5051
VOLTAGE LOGGER LR5041, LR5042, LR5043
Recorders
Data Loggers
Physical appearance
LR5001
LR5021
LR5001
LR5001
LR5011
LR5011
LR5031
LR5001
Temperature 1ch and
Humidity 1ch
Measurement items
LR5011
LR5041
LR5021
LR5021
LR5042
LR5031
LR5031
LR5021
LR5011
LR5011
LR5011
LR5021
LR5021
LR5031
LR5021
LR5031
LR5041
LR5031
LR5041
LR5042
LR5041
LR5042
LR5043
LR5042
LR5043
LR5051
LR5043
LR5051
LR5061
LR5051
LR5061 LR5061
LR5001
LR5001
LR5001
LR5043
LR5041
LR5041
LR5031
LR5051
LR5042
LR5042
LR5041
LR5061
LR5043
LR5043
LR5042
LR5051
LR5051
LR5043
LR5061
LR5061
LR5051
LR5061
Temperature 1ch
Temperature : -40 to 85.0 ˚C
Humidity : 0 to 100 % rh
Measurement range
Basic Accuracy
LR5011
AC Current 2ch
Instrumentation signal 1ch
-40.0 to 180.0 ˚C
DC voltage 1ch
(used with the optional current sensor; load current
2ch, leak current 2ch, or load/leak each 1ch)
-30.00 to 30.00 mA DC
LR5041: ±50.00 mV DC
LR5042: ±5.000 V DC
LR5043: ±50.00 V DC
0.00 to 1000 A AC
Temperature: ±0.5 ˚C(at 0.0 to 35.0 ˚C )
Main unit + sensor accuracy
±0.5 °C(at 0.0 to 35.0 ˚C )
±0.5 % rdg. ±5 dgt.
(at Main unit + CT6500 sensor accuracy, 500.0 A range, 50/60
Hz, typical value, refer to the detailed catalog
±0.5 % rdg. ±5 dgt.
Humidity sensor is bundled
Sensor is sold separately
Connection Cable is bundled
Clamp sensor is sold separately
Connection Cable is bundled
Typical value, refer to the detailed
Humidity: ±5 % rh (at 20 to 30 ˚C, at 10 to 50 % rh)
catalog
Other
±2.0 % rdg. ±0.13 % f.s.
Options
Recording and managing temperature and
humidity in offices and plants
WALL-MOUNTED
HOLDER LR9901
MAGNETIC STRAP
Z5004
Not compatible with Model
LR5051
Recording and measuring current in plant and
building equipment
Transfer Data from a LR5000 Series Data Logger to PC
COMMUNICATION ADAPTER LR5091
DATA COLLECTOR LR5092-20
■ Basic specifications
LR5091
marked
marked
LR5092
LR5091
(USB cable is bundled )
LR5092
(USB cable is bundled )
• Bring the data logger LR5000 series back from the field and transfer data to a PC
• Save data from data loggers in the built-in memory or on an SD card (LR5092-20)
• Send settings from a PC to a data logger
• Use the included software to easily graph and print data
• Use the included software to calculate maximum, minimum, and average values
and more between cursors
Storage media
Note: Communication adapter LR5091 or
Data collector LR5092-20 is necessary
to transfer data from a LR5000 series
Logger to a PC
SD Card Precaution
SD MEMORY CARD
2GB Z4001
2GB capacity
LR5000 Utility
(PC communications software; included)
Table and graph display, data analysis, data
processing, transmission of settings to data
loggers, print functionality, etc.
*The utility can also display data collected using the Data
Logger 3630 series
28
Use only SD Cards sold by
HIOKI. Compatibility and
performance are not guaranteed
for SD cards made by other
manufacturers. You may be
unable to read from or save data
to such cards.
LR5092-20
Send data from a data logger to the internal
memory or an SD card, then display a graph.
Transfer data from a data logger to a PC Send settings and the time from the internal
Send settings and the time from a PC to a memory or SD card to a data logger.
Function
Send data from a data logger to a PC.
data logger.
Send settings and the time from a PC to a data
logger.
Between data loggers: Infrared communiBetween data loggers: Infrared communications
Communications cations
With PC: USB 2.0
method
With PC: USB 2.0
Data logger setting conditions
N/A
Display
Collected data (as list, graph, values, etc.)
60,000 data elements ×16ch (instantaneous value
Internal memory
capacity of data
N/A
Removable
storage media
N/A
mode)
15,000 data elements ×16ch (statistical value mode)
Data logger settings (max. 1 set)
SD Memory card
Save data and max. 16 items configuration
DC 3 V (LR6 (AA) Alkaline battery ×2)
USB bus power (12 hours or 500 times of data collection)
Dimensions and 83 mm (3.27 in)W × 61 mm (2.40 in) H 91 mm (3.58 in)W × 141 mm (5.55 in)H × 31 mm
(1.22 in)D, 215 g (7.6 oz) (excluding batteries and
× 19 mm (0.75 in)D, 43 g (1.5 oz)
Power supply
USB bus power
mass
Accessories
SD memory card)
USB cable (1m) ×1, CD (Application
software "LR5000 Utility") ×1
Instruction manual ×1, Operation guide ×1, LR6
(AA) Alkaline battery ×2, USB cable (1m) ×1,
CD (Application software "LR5000 Utility") × 1
■ LR5000 Utility Specifications
OS: Windows 7 (32/64bit, .NET Framework 2.0 or more), Vista (32bit, SP1 or more), XP
Operating
(SP2 or more)
environment
*USB interface (when using the Communication Base 3910/3911, a COM port is required)
Function
• Settings: Communicates via infrared light with LR5000 series loggers to
send and receive settings.
• Graph function: Displays graphs of up to 16 channels, displays statistical
data, etc.
• Print function: Print graphs, Print statistical data.
• Export function (data CSV output, paste into Excel)
• Import function (loads text files from the Clamp On Power HiTester 3169-20/-21
[only demand parameter with a recording interval of at least 1 sec.])
• Processing of data: Scaling, Power calculation, Energy cost calculation,
Operating ratio calculation, Integration, Dew point temperature, Calculate
between channels
Recorders • Data Loggers
Easily Record Load Current of 50Hz/60Hz lines and Leak Current
CLAMP LOGGER LR5051
■ Basic specifications (Accuracy guaranteed for 1 year)
AC Current 2 channels (used with the optional current sensor; load current 2ch,
Measurement items leak current 2ch, or load/leak each 1ch)
marked
clamp sensor accuracy, refer to the detailed catalog
Storage capacity
Recording interval
Instantaneous value mode: 60,000 data/ch, Statistical value mode: 15,000 data/ch
1 to 30 sec., 1 to 60 min., 15 selections
Instantaneous recording: at every recording interval
Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval
One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is full (old data
is overwritten)
Recording methods Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording)
Always backs up last recorded data; backs up recorded data and setting conditions when
battery power is low; guarantees approx. 30 sec. of recording operation and clock
Other functions
while battery is replaced
Recording modes
*Clamp sensor is sold separately
•Easily mount the light-weight , pocket-sized loggers in tight spaces
•Easy-to-see dual display
•Transfer data to PC even during recording
•Replace batteries while recording (30 second limit)
•3 times the memory capacity compared to predecessor (Record 60,000 data per channel)
•Record without missing fluctuations in STAT mode
•Measurement data is preserved even after the battery dies
•Worry-free backup preserves recorded data even if a new measurement is
started by mistake
(PC communication)
COMMUNICATION
ADAPTER LR5091
Dock logger and transfer data
via optical communication
Dock logger or transfer
data to internal memory/
SD memory card
Other options
Options
DATA COLLECTOR
LR5092-20
MAGNETIC STRAP
Z5004
Waterproof and dust-proof N/A
Interfaces
Infrared optical communications with LR5091, LR5092-20
Power supply
LR6 (AA) Alkaline battery ×2, Battery life: Approx. 1 year (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 1 month
(Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in)W × 70 mm (2.76 in)H × 37 mm (1.46 in)D, 165 g (5.8 oz)
LR6 (AA) Alkaline battery (built-in internal) ×2, Instruction manual ×1, Operation guide ×1
Accessories
Insulated
wire
Optional sensors
Customers using the previous Model 3636-20 Clamp Logger should note that the LR5051 can
only record 15,000 points of average data, vs. 32,000 data points available in the 3636-20.
Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data
from a LR5000 series Logger to a PC
Recorders
Data Loggers
Measurement range AC 500.0 mA to 1000 A rms, 5 range (depends on current sensor in use)
±2.0% rdg. ±0.13% f.s. (main unit + current sensor accuracy, at 500.0 A range, 50/60 Hz)
Basic Accuracy
Note: Basic accuracy is typical value, only main unit accuracy: ±0.5 %rdg. ±5 dgt., must added
CLAMP ON SENSOR
CT6500
CLAMP ON SENSOR
9669
CLAMP ON SENSOR
9695-02
500 A AC, line voltage 600 V 1000 A AC, line voltage 600 50 A AC, line voltage 300
or less, φ46 mm (1.81 in) core V or less, φ55 mm (2.17 in)
V or less, φ15 mm (0.59 in)
dia., 3 m (9.84 ft) cord length core dia. or 80 mm×20 mm, 3 core dia. or 80 mm×20 mm,
m (9.84 ft) cord length
Cable 9219 required
CLAMP ON LEAK
SENSOR 9657-10
Insulated
Primary rated 10 A AC, line
wire
voltage 300 V or less,φ40
mm (1.57 in) core dia., 3 m
(9.84 ft) cord length
Insulated
wire
CLAMP ON LEAK
SENSOR 9675
Primary rated 10 A AC, line
voltage 300 V or less, φ30
mm (1.18 in) core dia., 3 m
(9.84 ft) cord length
CONNECTION CABLE
9219
Connect with the 9695-02/
-03, Output BNC terminal
Record Instrumentation Signals and Measure Analog Output from Sensors and other Devices
VOLTAGE LOGGER (50mV) LR5041
VOLTAGE LOGGER (5V) LR5042, (50V) LR5043
marked
Bundled accessory (LR9802)
IP54
(splash-proof construction)
•Easily mount the light-weight , pocket-sized loggers in tight spaces
•Easy-to-see dual display
•Transfer data to PC even during recording
•Replace batteries while recording (30 second limit)
•3 times the memory capacity than predecessor (Record 60,000 data per channel)
•Record without missing fluctuations in STAT mode
•Measurement data is preserved even after the battery dies
•Worry-free backup preserves recorded data even if a new measurement is
started by mistake
• LR5041 (±50mV DC), • LR5042 ( ±5V DC), • LR5043 (±50V DC)
Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data
from a LR5000 series Logger to a PC
■ Basic specifications (Accuracy guaranteed for 1 year)
LR5041
LR5042
LR5043
DC voltage 1ch
DC voltage 1ch
DC voltage 1ch
Measurement items
−5.000 to 5.000 V
−50.00 to 50.00 V
Measurement range −50.00 to 50.00 mV
±0.5 %rdg. ±5 dgt.
Accuracy
Storage capacity Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data
Recording interval 1 to 30 sec., 1 to 60 min., 15 selections
Instantaneous recording: at every recording interval
Statistical value recording: Measure at one second intervals, and record
Recording modes
the instantaneous, maximum, minimum, and average values within every
recording interval
One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is
Recording meth- full (old data is overwritten)
Start: Logger button operation or scheduled time
ods
Stop: Logger button operation or scheduled time, or auto-stop when the
memory capacity is full (at one-time recording)
Pre-heat function (requires external power supply during use of function), Always
backs up last recorded data; backs up recorded data and setting conditions
Other functions
when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced
Waterproof and
IP54 (EN60529) (with connection cable connected, but not including cable tip)
dust-proof
Infrared optical communications with LR5091, LR5092-20
Interfaces
LR6 (AA) Alkaline battery ×1, Battery life: Approx. 2 years (Instantaneous
recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 2
Power supply
months (Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in)W × 57 mm (2.246 in)H × 28 mm (1.10 in)D, 105 g (3.7 oz)
LR6 (AA) Alkaline battery (built-in internal) ×1, Connection cable LR9802
Accessories
×1, Instruction manual ×1, Operation guide ×1, Kickstand ×1
(PC communication)
Dock logger and transfer data
via optical communication
Dock logger or transfer
data to internal memory/
SD memory card
MAGNETIC
WALL-MOUNTED
STRAP Z5004 HOLDER LR9901
Not compatible with
Model LR5051
Bundled accessory
COMMUNICATION
ADAPTER LR5091
Other options
Options
DATA COLLECTOR
LR5092-20
CONNECTION CABLE
LR9802
Tips 4 wires, 1 m (3.28 ft) length
29
Recorders • Data Loggers
For 4-20 mA Instrumentation Measurement
INSTRUMENTATION LOGGER LR5031
marked
Recorders
Data Loggers
Bundled accessory (LR9801)
IP54
(splash-proof construction)
•4 - 20 mA DC measurement only
•Easily mount the light-weight , pocket-sized loggers in tight spaces
•Easy-to-see dual display
•Transfer data to PC even during recording
•Replace batteries while recording (30 second limit)
•3 times the memory capacity than predecessor (Record 60,000 data per channel)
•Measurement data is preserved even after the battery dies
•Worry-free backup preserves recorded data even if a new measurement is
started by mistake
Note: Communication adapter LR5091 or Data
collector LR5092-20 is necessary to transfer data from
a LR5000 series Logger to a PC
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement items For Instrumentation / 0 to 20mA DC, 1ch
Measurement range -30.00 to 30.00 mA
±0.5 %rdg. ±5 dgt.
Accuracy
Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data
Storage capacity
Recording interval 1 to 30 sec., 1 to 60 min., 15 selections
Instantaneous recording: at every recording interval
Statistical value recording: Measure at one second intervals, and record
Recording modes
the instantaneous, maximum, minimum, and average values within every
recording interval
One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is
full (old data is overwritten)
Recording methods
Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the
memory capacity is full (at one-time recording)
Always backs up last recorded data; backs up recorded data and setting
conditions when battery power is low; guarantees approx. 30 sec. of
Other functions
recording operation and clock while battery is replaced
Waterproof and
IP54 (EN60529) (with connection cable connected, but not including cable tip)
dust-proof
Infrared optical communications with LR5091, LR5092-20
Interfaces
LR6 (AA) Alkaline battery ×1, Battery life: Approx. 2 years (Instantaneous
recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 2
Power supply
months (Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in)W × 57 mm (2.246 in)H × 28 mm (1.10 in)D, 105 g (3.7 oz)
LR6 (AA) Alkaline battery (built-in internal) ×1, Connection cable LR9801
Accessories
×1, Instruction manual ×1, Operation guide ×1, Kickstand ×1
(PC communication)
MAGNETIC
WALL-MOUNTED
STRAP Z5004 HOLDER LR9901
Not compatible with
Model LR5051
Bundled accessory
Dock logger and transfer data
via optical communication
Dock logger or transfer
data to internal memory/
SD memory card
Other options
Options
DATA COLLECTOR
LR5092-20
COMMUNICATION
ADAPTER LR5091
CONNECTION CABLE
LR9801
Tips 2 wires, 1 m (3.28 ft) length
Measure Temperature with External Sensor
TEMPERATURE LOGGER LR5011
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement items Temperature 1ch (with optional sensor)
Measurement range −40.0 °C to 180.0 °C *Depends on measurement range of sensor
±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C)
Basic Accuracy
Note: Basic accuracy is typical value, refer to the detailed catalog
Optional sensor (LR9604)
IP54
(splash-proof construction)
•Easily mount the light-weight , pocket-sized loggers in tight spaces
•Easy-to-see dual display
•Transfer data to PC even during recording
•Replace batteries while recording (30 second limit)
•3 times the memory capacity than predecessor (Record 60,000 data per channel)
•Record without missing fluctuations in STAT mode
•Measurement data is preserved even after the battery dies
•Worry-free backup preserves recorded data even if a new measurement is
started by mistake
Storage capacity
Recording interval
Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data
1 to 30 sec., 1 to 60 min., 15 selections
Instantaneous recording: at every recording interval
Statistical value recording: Measure at one second intervals, and record
Recording modes
the instantaneous, maximum, minimum, and average values within every
recording interval
One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is
full (old data is overwritten)
Recording methods Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the
memory capacity is full (at one-time recording)
Always backs up last recorded data; backs up recorded data and setting
conditions when battery power is low; guarantees approx. 30 sec. of
Other functions
recording operation and clock while battery is replaced
Waterproof and
IP54 (EN60529) (with sensor connected, but not including sensor tip)
dust-proof
Infrared optical communications with LR5091, LR5092-20
Interfaces
LR6 (AA) Alkaline battery ×1, Battery life: Approx. 2 years (Instantaneous
recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 2
Power supply
months (Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in)W × 57 mm (2.246 in)H × 28 mm (1.10 in)D, 105 g (3.7 oz)
LR6 (AA) Alkaline battery (built-in internal) ×1, Instruction manual ×1,
Accessories
Operation guide ×1, Kickstand ×1
Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data
from a LR5000 series Logger to a PC
COMMUNICATION
ADAPTER LR5091
Dock logger and transfer data
via optical communication
30
Dock logger or transfer
data to internal memory/
SD memory card
Other options
Options
DATA COLLECTOR
LR5092-20
MAGNETIC WALL-MOUNTED
STRAP
HOLDER LR9901
Not compatible with
Z5004
Model LR5051
Optional sensors
(PC communication)
(Molded plastic type)
Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
Response time : 100 sec (90% response time)
Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)
LR9601
LR9602
LR9603
LR9604
1 m (3.28 ft) length
5 m (16.41 ft)
10 m (32.81 ft)
45 mm (1.77 in)
(Lug type)
Temperature range : -30 to 180 ˚C (-22 to 356 ˚F)
Response time : 45 sec (90% response time)
Outer diameter: φ7 mm (0.26 in)
Inner diameter: φ3.2 mm (0.13 in)
LR9611 1 m (3.28 ft) length
LR9612 5 m (16.41 ft)
LR9613 10 m (32.81 ft)
(Sheathed type)
Temperature range : -40 to 120 ˚C (-40 to 248 ˚F)
Response time : 90 sec (90% response time)
Sensor head size: φ4 × 180 mm (0.16 in × 7.09 in)
LR9621 1 m (3.28 ft) length
(Needle type)
Temperature range : -40 to 120 ˚C (-40 to 248 ˚F)
Response time : 20 sec (90% response time)
Sensor head size: φ1.3 × 25 mm (0.05 in × 0.98 in)
LR9631 1 m (3.28 ft) length
Recorders • Data Loggers
Record Temperature and Humidity Simultaneously
HUMIDITY LOGGER LR5001
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement items Temperature 1ch and Humidity 1ch (Requires included or optional humidity sensor)
Measurement range Temperature: −40.0 to 85.0 °C, Humidity: 0 to 100 % rh *at sensor environment
[Temperature] : ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C)
[Humidity] : ±5 % rh (main unit + temperature / humidity sensor LR950x comBasic Accuracy
Storage capacity
Recording interval
IP54
(splash-proof construction)
•Easily mount the light-weight , pocket-sized loggers in tight spaces
•Easy-to-see dual display
•Transfer data to PC even during recording
•Replace batteries while recording (30 second limit)
Note: Recording is interrupted during battery replacement if the battery is very weak. After
batteries are replaced, recording resumes automatically. Previously recorded data is not lost
during battery replacement.
•7 times the memory capacity than predecessor (Record 60,000 data
per channel)
•Record without missing fluctuations in STAT mode
•Measurement data is preserved even after the battery dies
•Worry-free backup preserves recorded data even if a new measurement is
started by mistake
Note: Communication adapter LR5091 or Data collector LR5092-20 is necessary to transfer data
from a LR5000 series Logger to a PC
Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data
1 to 30 sec., 1 to 60 min., 15 selections
Instantaneous recording: at every recording interval
Statistical value recording: Measure at one second intervals, and record
Recording modes
the instantaneous, maximum, minimum, and average values within every
recording interval
One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is
full (old data is overwritten)
Recording methods
Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the
memory capacity is full (at one-time recording)
Always backs up last recorded data; backs up recorded data and setting
conditions when battery power is low
Other functions
Recorders
Data Loggers
bination, at 20 to 30 °C / 10 to 50 % rh)
Note: Basic accuracy is typical value, refer to the detailed catalog
Bundled sensor (LR9504)
Note: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement)
Waterproof and
dust-proof
Interfaces
Power supply
IP54 (EN60529) (with sensor connected, but not including sensor tip)
Infrared optical communications with LR5091, LR5092-20
LR6 (AA) Alkaline battery ×1, Battery life: Approx. 3 months (Instantaneous
recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 20 days
(Instantaneous recording, with 1-second interval at 20 °C)
(typical data: Approx. 1 yeare recording with 10-minutes interval)
Dimensions and mass 79 mm (3.11 in)W × 57 mm (2.246 in)H × 28 mm (1.10 in)D, 105 g (3.7 oz)
LR6 (AA) Alkaline battery (built-in internal) ×1, Humidity sensor LR9504
Accessories
×1, Instruction manual ×1, Operation guide ×1, Kickstand ×1
(LR9504 is bundled accessory)
COMMUNICATION
ADAPTER LR5091
Dock logger and transfer data
via optical communication
Dock logger or transfer
data to internal memory/
SD memory card
Other options
Options
DATA COLLECTOR
LR5092-20
MAGNETIC WALL-MOUNTED
STRAP
HOLDER LR9901
Not compatible with
Z5004
Model LR5051
Optional sensors
(PC communication)
Temperature range: -40 to 85 ˚C
Humidity range: 0 to 100 % rh
Response time: 300 seconds
(90 % response time)
Waterproof: None
Sensor size: 13×30 mm
(0.51×1.18 in)
LR9501 1 m (3.28 ft) length
LR9502 5 m (16.41 ft)
LR9503 10 m (32.81 ft)
LR9504 40 mm (1.57 in) length
31
LCR Meters
Measure Electrochemical Components and Materials, Batteries, and EDLCs* (*Electric double-layer capacitors)
CHEMICAL IMPEDANCE ANALYZER IM3590
■ Basic specifications (Accuracy guaranteed for 1 year)
LCR mode, Continuous measurement mode (LCR mode / Analyzer mode),
Analyzer mode (Sweeps with measurement frequency and measurement level,
Measurement
modes
option
option
option
temperature characteristics, equivalent circuit analysis)
Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
Measurement
D (tanδ), Q, T, σ (conductivity), ε (dielectric constant)
parameters
Measurement range 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp, σ, ε :
±(0.00000 [unit] to 9.99999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 999.999°), D : ±(0.00000 to 9.99999)
Q : ±(0.00 to 9999.99), Δ % : ±(0.000% to 999.999%)
T : -10.0°C to 99.9°C
Display range
marked
LCR Meters
Z : ±0.05%rdg. θ: ±0.03°
Basic accuracy
Measurement frequency 1 mHz to 200 kHz (1 mHz to 10 Hz steps)
•Broad 1 mHz to 200 kHz signal source range supports measurements of ion behavior
and solution resistance
•Continuous measuring and high-speed testing of LCR and sweep measurements with a
single instrument
•Measures internal impedance of batteries with no load
•Performs high-speed sweep measurements in as little as 2 ms
•Basic accuracy of ±0.05% is ideal for applications from component testing to R&D
•Supports LCR impedance measurements for Cole-Cole plots and equivalent-circuit
analyses of electro-chemical components and materials
This product is not supplied with measurement probes or test fixtures. Please select and purchase
the measurement probe or test fixture options appropriate for your application separately.
For an RS-232C connection: A crossover cable for interconnection can be used. You can use the
RS-232C Cable 9637 without hardware flow control.
Normal mode:
V mode/CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
Low impedance high accuracy mode:
V mode/CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
CC mode:10 μA to 100 mArms, 10 μArms steps
Measurement
signal level
Output impedance Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω
5.7-inch color TFT, display can be set to ON/OFF
Display
Measurement time 2 ms (1 kHz, FAST, display OFF, representative value)
DC bias measurement, DC resistance temperature compensation (converted reference temperature is displayed), Temperature measurement,
Functions
Battery mesurement (Automatic DC biasing system), Comparator, BIN
measurement (classification), Panel loading/saving, Memory function
EXT I/O (Handler), USB communication (high-speed), USB memory
Interfaces
Optional: Choose 1 from RS-232C, GP-IB, or LAN
100 to 240 V AC, 50/60 Hz, 50 VA max.
Power supply
Dimensions and mass 330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) D, 3.1 kg (109.3 oz)
Power cord ×1, Instruction manual ×1, CD-R (Communication instruction
manual and sample software [Communications control, accuracy calculaAccessories
tion, and screen capture functionality] ) ×1
When using the 9268-10 or 9269-10, external constantvoltage and constant-current sources are required.
PINCHER PROBE 9143-10
TEST FIXTURE 9261-10
Cable length 1 m (3.28 ft), DC to 5
MHz, impedance characteristics
of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 5 mm
(0.20 in)
Cable length 1 m (3.28 ft), DC to 5
MHz, impedance characteristics of
50 Ω, 4-terminal pair configuration,
tip electrode spacing: 0.3 (0.01 in) to
6 mm (0.24 in)
Cable length 1 m (3.28 ft), DC to 5 MHz,
impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)
SMD TEST FIXTURE 9677
Direct connection type, For mea Cable length 1 m (3.28 ft), DC to 200 suring SMDs with electrodes on
kHz, impedance characteristics of 50 the side; DC to 120 MHz, test
Ω, measurable conductor diameter:
sample dimensions: 3.5 mm ±0.5
φ0.3 mm (0.01 in) to 2 mm (0.08 in)
mm (0.14 in ±0.02 in)
32
SMD TEST FIXTURE 9699
Direct connection type, For measuring SMDs with electrodes on
the bottom; DC to 120 MHz, test
sample dimensions: 1.0 mm (0.04
in) to 4.0 mm (0.16 in) wide, max.
1.5 mm (0.06 in) high
TEST FIXTURE 9262
SMD TEST FIXTURE 9263 DC BIAS VOLTAGE
DC BIAS CURRENT
Direct connection type, DC to Direct connection type, DC to 5 UNIT 9268-10
UNIT 9269-10
5 MHz, measurable conductor MHz, Test sample dimensions:1 Direct connection type, 40 Direct connection type, 40
diameter: ø0.3 (0.01 in) to 2
mm (0.04 in) to 10 mm (0.39 in) Hz to 5 MHz, maximum
Hz to 2 MHz, maximum
mm (0.08 in)
applied voltage of DC ±40 V applied current of DC 2 A
GP-IB INTERFACE
Z3000
RS-232C
LAN INTERFACE
INTERFACE Z3001 Z3002
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
Temperature probe
4-TERMINAL PROBE 9500-10
Cable length 1 m (3.28 ft), DC to
200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 5 mm
(0.20 in)
PC communication
Probe and Test fixtures
4-TERMINAL PROBE L2000 4-TERMINAL PROBE 9140-10
SHEATH TYPE TEMPERATURE
PROBE 9478
Pt100, Tip dia. φ2.3 mm (0.09 in), Cord length
1 m (3.28 ft), Waterproof construction
LCR Meters
Single Device Solution for High Speed Testing and Frequency Sweeping
IMPEDANCE ANALYZER IM3570
■ Basic specifications (Accuracy guaranteed for 1 year)
marked
LCR mode, Analyzer mode (Sweeps with measurement frequency and
measurement level), Continuous measurement mode
Measurement
parameters
Measurement range
Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
D (tanδ), Q
100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z)
Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
Display range
±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 999.999°), D : ±(0.000000 to 9.999999)
Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%)
Z : ±0.08%rdg. θ: ±0.05°
Basic accuracy
Measurement frequency 4 Hz to 5 MHz (10 mHz to 100 Hz steps)
Normal mode:
V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz)
10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps
CC mode: 10 μA to 50 mArms (up to 1 MHz)
Measurement
10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps
signal level
Low impedance high accuracy mode:
V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps
CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz),
10 μArms steps
Output impedance Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
5.7-inch color TFT, display can be set to ON/OFF
Display
Measurement time 0.5 ms (100 kHz, FAST, display OFF, representative value)
DC bias measurement, Comparator, BIN measurement (classification),
Functions
Panel loading/saving, Memory function
LCR Meters
•LCR measurement, DCR measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument
•High-speed testing, achieving maximum speeds of 1.5ms (1 kHz) and 0.5ms (100kHz)
in LCR mode
•High-accuracy measurements, basic accuracy of Z parameter: ± 0.08%
•Perfect impedance analyzer for testing the resonance characteristics of piezoelectric
elements, C-D and low ESR measurement of functional polymer capacitors, DCR and
L-Q measurement of inductors (coils and transformers)
•Perform frequency sweeps, level sweeps, and time interval measurements in analyzer
mode
Measurement
modes
EXT I/O (handler), RS-232C, GP-IB, USB communication, USB
memory, LAN
90 to 264 V AC, 50/60 Hz, 150 VA max.
Power supply
Dimensions and mass 330 mm (12.99 in) W × 119 mm (4.69 in) H × 307 mm (12.09 in) D, 5.8 kg (204.6 oz)
Power cord ×1, Instruction manual ×1, PC communication instruction
Accessories
manual (CD-R) ×1
Interfaces
This product is not supplied with measurement probes or test fixtures. Please select and purchase
the measurement probe or test fixture options appropriate for your application separately.
For an RS-232C connection: A crossover cable for interconnection can be used. You can use the
RS-232C CABLE 9637 without hardware flow control.
When using the 9268-10 or 9269-10, external constantvoltage and constant-current sources are required.
PINCHER PROBE 9143-10
TEST FIXTURE 9261-10
Cable length 1 m (3.28 ft), DC to 5
MHz, impedance characteristics
of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 5 mm
(0.20 in)
Cable length 1 m (3.28 ft), DC to 5
MHz, impedance characteristics of
50 Ω, 4-terminal pair configuration,
tip electrode spacing: 0.3 (0.01 in) to
6 mm (0.24 in)
Cable length 1 m (3.28 ft), DC to 5 MHz,
impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)
Cable length 1 m (3.28 ft), DC to
200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 5 mm
(0.20 in)
SMD TEST FIXTURE 9699
Direct connection type, For mea4-TERMINAL PROBE 9500-10
Direct connection type, For mea- suring SMDs with electrodes on
Cable length 1 m (3.28 ft), DC to 200 suring SMDs with electrodes on
the bottom; DC to 120 MHz, test
kHz, impedance characteristics of 50 the side; DC to 120 MHz, test
sample dimensions: 1.0 mm (0.04
Ω, measurable conductor diameter:
sample dimensions: 3.5 mm ±0.5 in) to 4.0 mm (0.16 in) wide, max.
φ0.3 mm (0.01 in) to 2 mm (0.08 in)
mm (0.14 in ±0.02 in)
1.5 mm (0.06 in) high
TEST FIXTURE 9262
SMD TEST FIXTURE 9263 DC BIAS VOLTAGE
DC BIAS CURRENT
Direct connection type, DC to Direct connection type, DC to 5 UNIT 9268-10
UNIT 9269-10
5 MHz, measurable conductor MHz, Test sample dimensions:1 Direct connection type, 40 Direct connection type, 40
diameter: ø0.3 (0.01 in) to 2
mm (0.04 in) to 10 mm (0.39 in) Hz to 5 MHz, maximum
Hz to 2 MHz, maximum
mm (0.08 in)
applied voltage of DC ±40 V applied current of DC 2 A
Note: Customers who have purchased the Impedance
Analyzer IM3570 can add the Equivalent Circuit
Analysis Firmware IM9000 function. Please contact
your local HIOKI representative.
EQUIVALENT CIRCUIT ANALYSIS FIRMWARE
IM9000
PC communication
SMD TEST FIXTURE 9677
Factory-installed option
Probe and Test fixtures
4-TERMINAL PROBE L2000 4-TERMINAL PROBE 9140-10
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
For the IM3570 (Factory-installed option)
Enabling Simple Circuit Analysis & Detailed Acceptance/Rejection Decision-Making
EQUIVALENT CIRCUIT ANALYSIS FIRMWARE IM9000
•The IM9000 can automatically select the equivalent circuit model from the five typical
models to minimize the differences between the measured values and the ideal frequency characteristics derived from the analysis results
•An acceptance/rejection decision can be made for the L, C, and R elements comprising a part and the resonance sharpness (mechanical quality coefficient)
•A detailed decision can be made on the elements using the resonance of a piezoelectric element or inductor
■ Basic specifications
Three-elements
model
Equivalent circuit model: Four models for Coil, Resistance, Capacitor
Measurement items: L1 (Inductance), C1 (Capacitance), R1 (Resistance),
Qm (Resonance sharpness),
fr (Resonance frequency) / fa (Anti-resonance frequency)
Four-elements
model
Equivalent crcuit model: One model for Pizoelectric element
Measurement items: L1 (Inductance), C1 (Capacitance), R1 (Resistance), C0
(Parallel capacitance), Qm (Resonance sharpness or mechanical quality
coefficient)
fr (Resonance frequency), fa (Anti-resonance frequency), fs (Series
resonance frequency), fp (Parallel resonance frequency), fm (Maximum
admittance frequency), fn (Minimum admittance frequency), f1
(Maximum susceptance frequency), f2 (Minimum susceptance frequency)
Other functions
Simulation: Enables displaying and comparing the ideal frequency
characteristics graph derived from the analysis results or the values
specified by the user
Comparator: Runs a comparator on the analysis results and outputs the
decision results to screen, EXT. I/O
X-Y display
Cole-Cole plot, Admittance circle display
The Equivalent Circuit Analysis Firmware IM9000 is an optional function for the Impedance
Analyzer IM3570. The IM9000 is not included in the standard package. If you want to use the
IM9000 function, specify the option upon purchase.
Customers who have purchased the Impedance Analyzer IM3570 can add the Equivalent Circuit
Analysis Firmware IM9000 function. Please contact your local HIOKI representative.
33
LCR Meters
From R&D Applications to Windings, Coil and Transformer Manufacturing
LCR METER IM3533, IM3533-01
■ Basic specifications (Accuracy guaranteed for 1 year)
IM3533
IM3533-01
LCR, Transformer testing (N, M, ΔL),
Analyzer (sweep testing), Continuous
Testing (LCR/Analyzer mode)
Z, Y, θ, Rs (ESR), Rp, DCR (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D
(tanδ), Q, N, M, ΔL, T
100 mΩ to 100 MΩ, 10 ranges (All parameters defined in terms of Z.)
Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp : ± (0.00000 [unit] to 9.99999G
[unit]) Real value display for Z and Y only
θ: ± (0.000° to 999.999°), D: ± (0.00000 to 9.99999)
Q: ± (0.00 to 9999.99), Δ%: ± (0.000% to 999.999%)
Z : ±0.05% rdg. θ: ±0.03°
1 mHz to 200 kHz (1 mHz to 10 Hz steps)
[Normal mode]
V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
[Low impedance high accuracy mode]
V mode, CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
CC mode: 10 μA to 100 mArms, 10 μArms steps
Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω
5.7-inch touch-screen color TFT, display can be set to ON/OFF
2 ms (1 kHz, FAST, display OFF, representative value)
DC bias measurement, DC resistance temperature compensation
(converted reference temperature display), Comparator, BIN
measurement (classify function), Panel loading/saving, Memory function
EXT I/O (Handler), USB communication (high-speed), USB memory
Optional: Choose 1 from RS-232C, GP-IB, or LAN
100 to 240 V AC, 50/60 Hz, 50 VA max
330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) D, 3.1 kg (109.3 oz)
Power cord ×1, Instruction manual ×1, CD-R (Includes PC commands and sample software) ×1
LCR, Transformer testing (N, M, ΔL),
Continuous testing (LCR mode)
Measurement
modes
option
option
Measurement
parameters
Measurement range
option
Displayable range
marked
LCR Meters
Basic accuracy
Measurement frequency
•±0.05% accuracy with wide measurement range (DC, 40Hz to 200kHz, 5mV to 5V, 10uA to 50mA)
•Non-stop testing over mixed measurement conditions such as C-D
and ESR at 10 times the speed of previous models
•Built-in low impedance high precision mode effective for testing low
inductance or the ESR of aluminum electrolysis capacitance
(10× the measurement speed and dramatic improvements in repeatability and stability over the previous model 3522-50)
•Dedicated modes for measuring transformer winding ratio, mutual
inductance and temperature compensated DCR
•Frequency sweep testing (IM3533-01 only)
•2m/4m cable setting in addition to the standard 0m/1m
This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or
test fixture options appropriate for your application separately. All probes are constructed with a 1.5D-2V coaxial cable.
For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637
without hardware flow control.
Measurement
signal level
Output impedance
Display
Measurement time
Functions
Interfaces
Power supply
Dimensions and mass
Accessories
Ideal for Production Lines and Automated Testing
LCR METER IM3523
■ Basic specifications (Accuracy guaranteed for 1 year)
option
option
option
marked
•±0.05% accuracy with wide measurement range (DC, 40Hz to 200kHz, 5mV to 5V, 10uA to 50mA)
•Non-stop testing over mixed measurement conditions such as C-D
and ESR at 10 times the speed of previous models (compare with the
model 3532-50)
•Built-in comparator and BIN functions
•Rapid 2msec test time
This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or
test fixture options appropriate for your application separately. All probes are constructed with a 1.5D-2V coaxial cable.
For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637
without hardware flow control.
Measurement modes LCR, Continuous testing
Z, Y, θ, Rs (ESR), Rp, DCR (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D
Measurement
(tanδ), Q
parameters
Measurement range 100 mΩ to 100 MΩ, 10 ranges (All parameters defined in terms of Z.)
Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp :
± (0.00000 [unit] to 9.99999G [unit]) Real value display for Z and Y only
Displayable range
θ: ± (0.000° to 999.999°), D: ± (0.00000 to 9.99999)
Q: ± (0.00 to 9999.99), Δ%: ± (0.000% to 999.999%)
Z : ±0.05% rdg. θ: ±0.03°
40 Hz to 200 kHz (1 mHz to 10 Hz steps)
[Normal mode]
V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
Normal mode: 100 Ω,
Monochrome LCD
2 ms (1 kHz, FAST, representative value)
Comparator, BIN measurement (classify function), Panel loading/saving,
Memory function
EXT I/O (handler), USB communication (high-speed)
Optional: Choose 1 from RS-232C, GP-IB, or LAN
100 to 240 V AC, 50/60 Hz, 50 VA max
260 mm (10.24 in) W × 88 mm (3.46 in) H × 203 mm (7.99 in) D, 2.4 kg (84.7 oz)
Power cord ×1, Instruction manual ×1, CD-R (Includes PC commands and sample software) ×1
Basic accuracy
Measurement frequency
Measurement
signal level
Output impedance
Display
Measurement time
Functions
Interfaces
Power supply
Dimensions and mass
Accessories
Common options for IM3523, IM3533 (-01)
When using the 9268-10 or 9269-10, external constantvoltage and constant-current sources are required.
PINCHER PROBE 9143-10
TEST FIXTURE 9261-10
Cable length 1 m (3.28 ft), DC to 5
MHz, impedance characteristics
of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 5 mm
(0.20 in)
Cable length 1 m (3.28 ft), DC to 5
MHz, impedance characteristics of
50 Ω, 4-terminal pair configuration,
tip electrode spacing: 0.3 (0.01 in) to
6 mm (0.24 in)
Cable length 1 m (3.28 ft), DC to 5 MHz,
impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)
Cable length 1 m (3.28 ft), DC to
200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor
diameter: ø0.3 (0.01 in) to 5 mm
(0.20 in)
SMD TEST FIXTURE 9699
Direct connection type, For mea4-TERMINAL PROBE 9500-10
Direct connection type, For mea- suring SMDs with electrodes on
Cable length 1 m (3.28 ft), DC to 200 suring SMDs with electrodes on
the bottom; DC to 120 MHz, test
kHz, impedance characteristics of 50 the side; DC to 120 MHz, test
sample dimensions: 1.0 mm (0.04
Ω, measurable conductor diameter:
sample dimensions: 3.5 mm ±0.5 in) to 4.0 mm (0.16 in) wide, max.
φ0.3 mm (0.01 in) to 2 mm (0.08 in)
mm (0.14 in ±0.02 in)
1.5 mm (0.06 in) high
34
TEST FIXTURE 9262
SMD TEST FIXTURE 9263 DC BIAS VOLTAGE
DC BIAS CURRENT
Direct connection type, DC to Direct connection type, DC to 5 UNIT 9268-10
UNIT 9269-10
5 MHz, measurable conductor MHz, Test sample dimensions:1 Direct connection type, 40 Direct connection type, 40
diameter: ø0.3 (0.01 in) to 2
mm (0.04 in) to 10 mm (0.39 in) Hz to 5 MHz, maximum
Hz to 2 MHz, maximum
mm (0.08 in)
applied voltage of DC ±40 V applied current of DC 2 A
*Used with only for the IM3533 / 3533-01
GP-IB INTERFACE
Z3000
RS-232C
LAN INTERFACE
INTERFACE Z3001 Z3002
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
Other options refer to the detailed catalog
Temperature probe
SMD TEST FIXTURE 9677
PC communication
Probe and Test fixtures
4-TERMINAL PROBE L2000 4-TERMINAL PROBE 9140-10
SHEATH TYPE TEMPERATURE
PROBE 9478
Pt100, Tip dia. φ2.3 mm (0.09 in), Cord length
1 m (3.28 ft), Waterproof construction
LCR Meters
Wide Measurement Frequency, 100 kHz to 120 MHz
LCR HiTESTER 3535
■ Basic specifications (Accuracy guaranteed for 6 months)
Measurement parameters |Z|, |Y|, θ, Rp, Rs (ESR), G, X, B, Cp, Cs, Lp, Ls, D (tanδ), Q
Measurement range 1 k/10 k/100 kΩ (Depend on the 9700-10, All parameters defined by |Z|)
1 kΩ range
10 kΩ range
100 kΩ range
Z, R 100 mΩ to 2 kΩ
1 kΩ to 20 kΩ
10 kΩ to 300 kΩ
C
0.66 pF to 15.9 μF 0.066 pF to 1.59 nF
4.4 fF to 159 pF
L 0.133 nH to 3.18 mH 1.33 μH to 31.8 mH 13.3 μH to 477 mH
θ
-180.00° to 180.00°
Extent of measurement impedance
(Note: All measurement
ranges except for |Z| are
for reference only)
marked
Basic accuracy
|Z|: ±0.5 % rdg., phase angle: ±0.3° (typ.)
Measurement frequency 100 kHz to 120 MHz (100 Hz to 100 kHz steps)
Factory
option
A Head Amp unit 9700-10 must be factory adjusted for dedicated use with the 3535 before delivery.
This product is not supplied with test fixtures. Please select and purchase the test fixture options
appropriate for your application separately.
Measurement range: 100 mΩ to 300 kΩ
Connect head amp unit to main unit
SMD TEST FIXTURE 9677
Direct connection type, For measuring SMDs with
electrodes on the side; DC to 120 MHz, test sample
dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)
*use of the 9677 with Model 3535 will not comply with CE mark
For printing numerical values
112 mm (4.41 in) paper width
RS-232C CABLE
9637
RS-232C CABLE
9638
For the PC, 9pin - 9pin, cross,
1.8m (5.91 ft) length
For the PC, 9pin - 25pin, cross,
1.8m (5.91 ft) length
Printer options
CONNECTION CABLE 9678
PRINTER 9442
PC communication
Probe and Test fixtures
Direct connection type, For measuring SMDs with
electrodes on the bottom; DC to 120 MHz, test sample
dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide,
max. 1.5 mm (0.06 in) high
Note: Head Amp Unit must be
factory adjusted for dedicated use
with the 3535 before delivery.
HEAD AMP UNIT 9700-10
SMD TEST FIXTURE 9699
LCR Meters
•High speed LCR testing (6ms/sample)
•Load Compensation Function
•BIN ( Classification ) Measurement
•Memory capable of storing up to 200 measured values
•Detachable Head Amp
• Print measured values and comparator results with the Printer 9442 (option)
5 mV to 1 V, 20 mA max. (100 kHz to 10.00 MHz)
Measurement signal 5 mV to 500 mV, 10 mA max. (10.01 MHz to 120 MHz), (1 mV steps)
200 µA to 20 mA: 1 V max. (100 kHz to 10.00 MHz)
level
200 µA to 10 mA: 0.5 V max. (10.01 MHz to 120 MHz), (10 µA steps)
Output impedance 50 Ω (at 100 kHz)
LCD with backlight display, 99999 (3, 4, or 5 digits unit setting possible)
Display
Measurement time 6 ms (nominal)
N/A
DC bias
Load Compensation Function, Classification (BIN) Measurement, Comparator,
Functions
Averaging, External input/Output (EXT. I/O), GP-IB or RS-232C interface
100V to 240 V AC, 50/60 Hz, 50 VA max.
Power supply
Dimensions and mass 360mm (14.17in) W × 130mm (5.12in) H × 360mm (14.17in) D, 8.3kg (292.8oz)
Quick start manual ×1, Instruction manual ×1, Power cord ×1
Accessories
GP-IB CONNECTOR CABLE
9151-02
2 m (6.56 ft) length
AC ADAPTER
9443-02
CONNECTION
CABLE 9444
RECORDING PAPER
1196
For the Printer 9442,
EU type
For the Printer 9442,
9 pin - 9 pin,
1.5 m (4.92 ft) length
For the Printer 9442, 112 mm
(4.41 in) × 25 m (82.03 ft),
10 rolls/set
Increased measurement speed of up to 5msec! 42Hz to 5MHz, wide test frequency range LCR meter
LCR HiTESTER 3532-50
■ Basic specifications (Accuracy guaranteed for 6 months)
Measurement parameters |Z|, |Y|, θ, Rp, Rs(ESR), G, X, B, Cp, Cs, Lp, Ls, D (tanδ), Q
Measurement range 100 mΩ to 100 MΩ, 10 ranges (All parameters defined by |Z|)
|Z|, R, X: 10.00 mΩ to 200.00 MΩ (depending on condition)
Extent of measure- θ: -180.00° to +180.00°, C: 0.3200 pF to 370.00 mF, L: 16.000 nH to 750.00 kH,
ment impedance
D: 0.00001 to 9.99999, Q: 0.01 to 999.99, |Y|, G, B: 5.0000 nS to 99.999 S
option
option
(Note: All measurement ranges except for |Z| are for reference only)
Basic accuracy
marked
|Z| : ±0.08 % rdg. θ: ±0.05°
Measurement frequency 42 Hz to 5 MHz (0.1 Hz to 1 kHz steps)
10 mV to 5V rms (up to 1 MHz)
Measurement signal 50 mV to 1V rms (1 MHz to 5 MHz), (1 mV rms steps)
10 μA to 100 mA rms (up to 1 MHz)
level
50 μA to 20 mA rms (1 MHz to 5 MHz), (10 μA rms steps)
Output impedance 50 Ω
LCD with backlight display, 99999 (3, 4, or 5 digits unit setting possible)
Display
FAST: 5 ms, NORMAL: 21 ms,
Measurement time
SLOW 1: 72 ms, SLOW 2: 140 ms (typical values for displaying |Z|)
Superimposed DC voltage, DC current to source signal (used with the optional
DC bias
•High speed measurement of 5ms
•High precision measurement of ±0.08% basic accuracy
•Interactive touch panel operation
•Zoom feature for easy viewing
•Print measurement values and comparator results (option)
DC bias unit and constant voltage or current source equipment)
This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or
test fixture options appropriate for your application separately.
For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9638 without
hardware flow control.
Functions
Comparator, External input/Output (EXT. I/O), GP-IB or RS-232C interface
(option) (Note: RS-232C interface required if used with the Printer 9442.)
Selectable 100, 120, 220 or 240 V AC ±10 %, 50/60 Hz, 50 VA max.
Power supply
Dimensions and mass 348mm (10.75in) W × 113mm (4.45in) H × 273mm (10.75in) D, 6.5kg (229.3oz)
Instruction manual ×1, Power cord ×1, Spare fuse ×1
Accessories
RS-232C INTERFACE 9593-01
Direct connection type, For
SMD TEST FIXTURE 9263 TEST FIXTURE 9262
measuring SMDs with electrodes Direct connection type, DC to 5 Direct connection type,
MHz, Test sample dimensions:1 DC to 5 MHz, measurable
on the side; DC to 120 MHz, test
mm (0.04 in) to 10 mm (0.39 in)
conductor diameter: ø0.3
sample dimensions: 3.5 mm ±0.5
(0.01 in) to 2 mm (0.08 in)
mm (0.14 in ±0.02 in)
PINCHER PROBE 9143 4-TERMINAL PROBE
TEST FIXTURE 9261
Impedance characteristics of Impedance characteristics of 9140
75 Ω, 4-terminal configuration, Other specifications are
the same as for the 9261-10
75 Ω, 4-terminal configura- DC to 100 kHz, impedance
tion, Other specifications are characteristics of 75 Ω,
the same as for the 9143-10
4-terminal configuration
GP-IB INTERFACE 9518-01
Built into rear panel
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
Using with the 9268/9269, Not CE marked
DC BIAS CURRENT
UNIT 9269
DC BIAS VOLTAGE UNIT DC BIAS VOLTAGE
9268
UNIT 9268-01
CONNECTION
CORD 9166
42 Hz to 100 kHz, Max.
allowable current: ±2A DC
42 Hz to 5 MHz, Max. allowable voltage: ± 40 V DC
Metal BNC to clip, 1.5 m
(4.92 ft) length
For HDMI, 42 Hz to 5
MHz, Max. allowable voltage: ±4V DC
CONNECTION CORD 9165
Cord has metallic BNC connectors at both ends, use at metallic
terminal, 1.5 m (4.92 ft) length,
Not CE marked
Printer options
Probe and Test fixtures
Direct connection type, For measuring
SMDs with electrodes on the bottom;
DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16
in) wide, max. 1.5 mm (0.06 in) high
SMD TEST FIXTURE 9677
PC communication
SMD TEST FIXTURE 9699
Built into rear panel
PRINTER 9442
For printing numerical
values 112 mm (4.41 in)
paper width
AC ADAPTER
9443-02
For the Printer 9442,
EU type
CONNECTION
CABLE 9446
RECORDING
PAPER 1196
For the Printer 9442,
25 pin - 9 pin, 1.5 m
(4.92 ft) length
For the Printer 9442, 112 mm
(4.41 in) × 25 m (82.03 ft),
10 rolls/set
35
LCR Meters
Compact & Powerful dedicated LCR measurement in 5 msec timeframes
LCR HiTESTER 3511-50
■ Basic specifications (Accuracy guaranteed for 6 months)
Measurement parameters |Z|, θ, R, C, L, D (tanδ), Q
|Z|, R: 10 mΩ to 200.00 MΩ θ: -90.00° to +90.00°
C (at 120 Hz): 9.40 pF to 999.99 mF, C (at 1 kHz): 0.940 pF to 99.999 mF
Measurement range
L (at 120 Hz): 14.00 µH to 200.00 kH, L (at 1 kHz): 1.600 µH to 20.000 kH
D: 0.0001 to 1.9900, Q: 0.85 to 999.99
|Z| : ±0.08 % rdg. θ: ±0.05°
Basic accuracy
Measurement frequency 120 Hz or 1 kHz
Measurement signal level 50 mV, 500 mV, 1 V rms
Output impedance 50 Ω
LED (5-digit display, full-scale count depends on range)
Display
Fast: 13 msec, Normal: 90 msec, Slow: 400 msec. (at 120 Hz)
Measurement time
Fast: 5 msec, Normal: 60 msec, Slow: 300 msec. (at 1 kHz)
DC voltage/DC current can be superimposed on the measurement signal.
DC bias
option
marked
LCR Meters
(Requires optional unit and external constant voltage source/constant current source.)
Panel save and load function, External input/Output (EXT. I/O), GP-IB (option) or RS-232C interface
Selectable 100, 120, 220 or 240V AC ±10%, 50/60Hz, 20VA max.
Power supply
Dimensions and mass 210 mm (8.27 in)W × 100 mm (3.94 in)H × 168 mm (6.61 in)D, 2.5 kg (88.2 oz)
Instruction manual ×1, Power cord ×1, Spare fuse ×1
Accessories
• High speed measurement: 5 ms (1 kHz) or 13 ms (120 Hz)
• Built-in high-speed comparator
• Measurement frequency: 1 kHz/120 Hz selectable
• From minute measurement with a maximum resolution of 0.01 pF to high-capacity
measurement up to 1 F
• Print measured values and comparator results with the Printer 9442 (option)
Functions
This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe
or test fixture options appropriate for your application separately. For an RS-232C connection: A crossover cable for
interconnection can be used. You can use the RS-232C CABLE 9637 without hardware flow control.
SMD TEST FIXTURE 9677
Direct connection type, For
SMD TEST FIXTURE 9263 TEST FIXTURE 9262
measuring SMDs with electrodes Direct connection type, DC to 5 Direct connection type, DC to
MHz, Test sample dimensions:1 5 MHz, measurable conductor
on the side; DC to 120 MHz, test
mm (0.04 in) to 10 mm (0.39 in)
diameter: ø0.3 (0.01 in) to 2
sample dimensions: 3.5 mm ±0.5
mm (0.08 in)
mm (0.14 in ±0.02 in)
TEST FIXTURE 9261
PINCHER PROBE 9143
Impedance characteristics of
Impedance characteristics of
75 Ω, 4-terminal configuration, 75 Ω, 4-terminal configuraOther specifications are the
tion, Other specifications are
same as for the 9261-10
the same as for the 9143-10
4-TERMINAL PROBE 9140
DC to 100 kHz, impedance
characteristics of 75 Ω, 4-terminal configuration
Built into rear panel
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
Note: The 9268-01 cannot use with the 3511-50, using with the 9268/9269, Not CE marked
CONNECTION CORD 9165
DC BIAS CURRENT
UNIT 9269
DC BIAS VOLTAGE UNIT
9268
CONNECTION
CORD 9166
42 Hz to 100 kHz, Max.
allowable current: ±2A DC
42 Hz to 5 MHz, Max. allowable voltage: ± 40 V DC
Metal BNC to clip, 1.5 m
(4.92 ft) length
General-purpose option for easy printing of values
Cord has metallic BNC connectors at both ends, use at metallic
terminal, 1.5 m (4.92 ft) length,
Not CE marked
PRINTER 9442
For printing numerical
values 112 mm (4.41 in)
paper width
AC ADAPTER
9443-02
For the Printer 9442,
EU type
CONNECTION
CABLE 9446
RECORDING
PAPER 1196
For the Printer 9442,
25 pin - 9 pin, 1.5 m
(4.92 ft) length
For the Printer 9442, 112 mm
(4.41 in) × 25 m (82.03 ft),
10 rolls/set
Supported models: 3511-50, 3522-50, 3532-50, 3532-80, 3535, ST5541/40, SM-8213/15/20, 3506/05,
3504-40/-50/-60, 3351, 3334/33/32/31, 3239/38/37, 3169, 3157/54
Printer 9442
■ Specifications overview
Printer options
Probe and Test fixtures
Direct connection type, For measuring
SMDs with electrodes on the bottom;
DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16
in) wide, max. 1.5 mm (0.06 in) high
PC communication
SMD TEST FIXTURE 9699
GP-IB INTERFACE
9518-01
marked
Interface
Paper width
Print speed
RS-232C
112 mm
52.5 cps (characters per second)
AC Adapter 9443-01 or included nickel-metal
hydride battery (sufficient for approx. 3,000
Power supply
rows of print when fully charged)
Dimensions and 160 mm (6.30 in)W × 67 mm (2.64 in)H ×
170 mm (6.69 in)D, 580 g (20.5 oz)
mass
• Used with the Connection Cable 9444:
3154, 3156, 3237 to 3239, 3331 to 3333, 3504 to 3506, 3511-50, 3535, ST5540s
• Used with Connection Cable 9446 and RS-232C interface: 3157, 3522-50, 3532-50/-80
• Used with RS-232C Cable 9271: 3169
Options (If your device requires an RS-232C interface, please purchase separately)
CONNECTION
CABLE 9444
CONNECTION RS-232C CABLE
CABLE 9446
9721
For the Printer 9442, For the Printer 9442, Mini DIN 9 pin to D-sub
9 pin - 9 pin, 1.5 m
25 pin - 9 pin, 1.5 m 9 pin, straight, 1.5 m
(4.92 ft) length
(4.92 ft) length
(4.92 ft) length
(Requires AC Adapter 9443-01 for power.)
AC ADAPTER
9443-02
RECORDING
PAPER 1196
For the Printer 9442, 112 mm
(4.41 in) × 25 m (82.03 ft),
For the Printer 9442, EU 10 rolls/set
type
Printer for low-resistance meters and battery testers capable of standard deviation, histogram, and other statistical processing
Digital Printer 9203
■ Specifications overview
Interface
Paper width
Interval printing
Manual printing
Power supply
Dimensions and
mass
36
marked
Centronics
58 mm
Select from 1 to 30 s, 1 to 30 min, or 1 hr
Print key or external input
100 to 240 V AC, 50/60 Hz
215 mm (8.46 in)W × 160 mm (6.30 in)H ×
54 mm (2.13 in)D, 1 kg (35.3 oz)
• Thermal printer capable of high-speed printing
• Supported models: 3540-02, 3560
• In addition to interval printing, automatically creates statistical processing such as
maximum, minimum, and average values as well as standard deviation and histograms.
• Number of data points that can be used in calculations: 99,999 points (histograms and
graph printing: up to 5,000 points)
The optional Connection Cable 9425 and Printer Interface 9589 are required in order to
connect the 9203 to the 3560. The optional Connection Cable 9425 is required in order to
connect the 9203 to the 3540-02.
■ Options
CONNECTION CABLE 9425
RECORDING PAPER 9233
20 pin - 36 pin, 2 m (6.56 ft) length
58 mm (2.28 in) × 10 m (32.81 ft), 10 rolls/set
LCR Meters
High-speed 1MHz C tester delivering super precise measurements even from low capacitance levels
C METER 3506-10
marked
2 m (6.56 ft) length
For printing numerical values
112 mm (4.41 in) paper width
AC ADAPTER
9443-02
For the Printer 9442,
EU type
CONNECTION CABLE 9444
RECORDING PAPER 1196
For the Printer 9442, 9 pin - 9 pin, 1.5 m For the Printer 9442, 112 mm (4.41 in)
(4.92 ft) length
× 25 m (82.03 ft), 10 rolls/set
Probe and Test fixtures
SMD TEST FIXTURE 9677
4-TERMINAL PROBE L2000 4-TERMINAL PROBE 9140-10 PINCHER PROBE 9143-10
1 m (3.28 ft) Cable length, DC
to 5 MHz, 50 Ω, measurable
conductor diameter: φ0.3 mm
(0.01 in) to 5 mm (0.20 in)
Cable length 1 m (3.28 ft), DC to
200 kHz, 50 Ω, measurable conductor diameter: φ0.3 mm (0.01
in) to 5 mm (0.20 in)
TEST FIXTURE 9261-10
LCR Meters
GP-IB CONNECTOR
CABLE 9151-02
PRINTER 9442
Printer options
This product is not supplied with measurement probes or test fixtures. Please select
and purchase the measurement probe or test fixture options appropriate for your
application separately.
For an RS-232C connection: A crossover cable for interconnection can be used. You
can use the RS-232C cable 9637 without hardware flow control.
PC communication
•High-speed analog test time of 0.6 ms (at 1 MHz)
•Improved noise resistance and enhanced repeatability in measurement
precision even for production lines
•1 kHz and 1 MHz measurement frequency supports
stable low capacitance testing with taping machines
•BIN function, for easy component screening
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement parameters C (Capacitance), D (loss coefficient, tan δ), Q (1/tan δ)
Measurement range C: 0.001 fF to 15.0000 μF, D: 0.00001 to 1.99999, Q: 0.0 to 19999.9
(Typ.) C: ±0.14 % rdg., D: ±0.0013
Basic accuracy
Measurement frequency 1 kHz, 1 MHz
Measurement signal level 500 mV, 1 V rms
Output impedance 1 Ω (at 1 kHz in 2.2 μF and higher ranges), 20 Ω (in ranges other than the above)
LED (six digits, full scale count depends on measurement range)
Display
Measurement time 1.5 ms: 1 MHz, 2.0 ms: 1 kHz
BIN (measurement values can be classified by rank), Trigger-synchronous output, Setting configurations can be stored, Comparator, Averaging, Low-C
Functions
reject (bad contact detection), Chatter detection, Current detection circuit
monitoring, Applied voltage value monitoring, EXT. I/O, RS-232C, GP-IB
Selectable 100, 120, 220 or 240 V AC ±10 %, 50/60 Hz 40 VA max.
Power supply
Dimensions and mass 260 mm (10.24 in) W × 100 mm (3.94 in) H × 298 mm (11.73 in) D, 4.8 kg (169.3 oz)
Power cord ×1, Instruction manual ×1, Spare fuse ×1
Accessories
TEST FIXTURE 9262
SMD TEST FIXTURE 9263
Cable length 1 m (3.28 ft), DC to 5 Cable length 1 m (3.28 ft), DC Direct connection type, DC to Direct connection type, DC to 5
MHz, 50 Ω, tip electrode spacing: to 5 MHz, 50 Ω, measurable
5 MHz, measurable conductor MHz, Test sample dimensions: 1
0.3 (0.01 in) to 6 mm (0.24 in)
conductor diameter: φ0.3 mm diameter: φ0.3 mm (0.01 in) to mm (0.04 in) to 10 mm (0.39 in)
(0.01 in) to 1.5 mm (0.06 in)
2 mm (0.08 in)
4-TERMINAL PROBE 9500-10
Cable length 1 m (3.28 ft), DC
to 200 kHz, 50 Ω, measurable
conductor diameter: φ0.3 mm
(0.01 in) to 2 mm (0.08 in)
SMD TEST FIXTURE 9699
Direct connection type, For
Direct connection type, For
measuring SMDs with electrodes measuring SMDs with electrodes
on the side; DC to 120 MHz, test on the bottom; DC to 120 MHz,
sample dimensions: 3.5 mm ±0.5 test sample dimens--ions: 1.0 mm
mm (0.14 in ±0.02 in)
(0.04 in) to 4.0 mm (0.16 in) wide,
maximum 1.5 mm (0.06 in) high
High-speed, Large-capacitance MLCC Inspection with Constant Voltage
C HiTESTER 3504-40, 3504-50, 3504-60
3504-50, 3504-60
marked
■ Basic specifications (Accuracy guaranteed for 6 months)
Measurement parameters C (capacitance), D (loss coefficient tan δ)
Measurement range C: 0.9400 pF to 20.0000 mF, D: 0.00001 to 1.99000
(Typ.) C: ±0.09 % rdg. ±10 dgt., D: ±0.0016
Basic accuracy
Measurement frequency 120 Hz, 1 kHz
100 mV (3504-60 only), 500 mV, 1 V rms
CV 100 mV Measurement range: up to 170 μF range (Source frequency 1 kHz), up
to 1.45 mF range (Source frequency 120 Hz)
Measurement signal CV 500 mV Measurement range : up to 170 μF range (Source frequency 1 kHz), up
level
to 1.45 mF range (Source frequency 120 Hz)
CV 1V Measurement range : up to 70 μF range (Source frequency 1 kHz), up to
700 μF range (Source frequency 120 Hz)
Output impedance 5Ω (In open terminal voltage mode outside of the CV measurement range)
LED (six digits, full scale count depends on measurement range)
Display
Measurement time 2 ms (Typ. value. Depends on measurement configuration settings)
Functions
Selectable 100, 120, 220 or 240 V AC ±10 %, 50/60 Hz, 110 VA max.
Power supply
Dimensions and mass 260 mm (10.24 in)W × 100 mm (3.94 in)H × 220 mm (8.66 in)D, 3.8 kg(134.0 oz)
Power cord ×1, Instruction manual ×1, Spare fuse ×1
Accessories
This product is not supplied with measurement probes or test fixtures. Please select and purchase
the measurement probe or test fixture options appropriate for your application separately. For an
RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C
CABLE 9637 without hardware flow control.
Direct connection type, For measuring
SMDs with electrodes on the bottom;
DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16
in) wide, max. 1.5 mm (0.06 in) high
PRINTER 9442
AC ADAPTER
For printing numerical 9443-02
values 112 mm (4.41 in) For the Printer 9442,
paper width
EU type
CONNECTION
CABLE 9444
RECORDING
PAPER 1196
For the Printer 9442,
9 pin - 9 pin,
1.5 m (4.92 ft) length
For the Printer 9442,
112 mm (4.41 in) × 25 m
(82.03 ft), 10 rolls/set
SMD TEST FIXTURE 9677
Direct connection type, For
SMD TEST FIXTURE 9263 TEST FIXTURE 9262
measuring SMDs with electrodes Direct connection type, DC to 5 Direct connection type, DC to
MHz, Test sample dimensions:1 5 MHz, measurable conductor
on the side; DC to 120 MHz, test
mm (0.04 in) to 10 mm (0.39 in)
diameter: ø0.3 (0.01 in) to 2
sample dimensions: 3.5 mm ±0.5
mm (0.08 in)
mm (0.14 in ±0.02 in)
TEST FIXTURE 9261
PINCHER PROBE 9143
Impedance characteristics of
Impedance characteristics of
75 Ω, 4-terminal configuration, 75 Ω, 4-terminal configuraOther specifications are the
tion, Other specifications are
same as for the 9261-10
the same as for the 9143-10
4-TERMINAL PROBE 9140
DC to 100 kHz, impedance
characteristics of 75 Ω, 4-terminal configuration
PC communication
Probe and Test fixtures
SMD TEST FIXTURE 9699
4-terminal contact check function (3504-60 only)
BIN (measurement values can be classified by rank) (3504-50, 3504-60), Triggersynchronous output, Setting configurations can be stored, Comparator,
Averaging, Low-C reject (bad contact detection), Chatter detection, EXT. I/O,
RS-232C (all models standard), GP-IB (3504-50, 3504-60)
Printer options
• High speed measurement of 2ms
• Supports C measurements with voltage dependency characteristics through
the use of constant voltage testing (CV)
• Model 3504-60 can detect contact failure on all 4 terminals for increased reliability
• BIN function on the 3504-60/-50 is ideal for sorting machines
• Model 3504-40 offers high speed and affordability, perfect for integrating into
taping machines
• In all models, contact error is constantly monitored during measurement,
contributing to increased yield
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
37
LCR Meters
For LCR Meter and Impedance Analyzer
Probes & Test Fixtures and Applicable SMD size
Please use the probes specified below. For probe characteristic impedance of 50 Ω, 50 Ω coaxial cable is used. For probe characteristic impedance of 75 Ω, 75 Ω coaxial
cable is used.
MAX : 2
Probes and Test Fixtures for Lead Components
LCR Meters
85
188
3
1000
TEST FIXTURE 9262
Cable length 1 m (3.28 ft), DC to 5 MHz,
impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable
conductor diameter: ø0.3 (0.01 in) to 5 mm
(0.20 in)
MAX φ5.0
94
84
Direct connection type, DC to
5 MHz, measurable conductor
diameter: ø0.3 (0.01 in) to 2 mm
(0.08 in)
20
MAX: 1.5
5
FOUR-TERMINAL PROBE
L2000
160
1000
FOUR-TERMINAL PROBE
9140
Cable length 1 m (3.28 ft), DC to 200
kHz, impedance characteristics of 50 Ω,
4-terminal pair configuration, measurable
conductor diameter: ø0.3 (0.01 in) to 5 mm
(0.20 in)
Cable length 1 m (3.28 ft), DC to
100 kHz, impedance characteristics
of 75 Ω, 4-terminal configuration,
measurable conductor diameter:
ø0.3 (0.01 in) to 5 mm (0.20 in)
5
FOUR-TERMINAL PROBE
9140-10
38
20
MAX φ5.0
38
TEST FIXTURE 9261-10
TEST FIXTURE 9261
Cable length 1 m (3.28 ft), DC to 5
MHz, impedance characteristics of
50 Ω, 4-terminal pair configuration,
measurable conductor diameter: ø0.3
(0.01 in) to 1.5 mm (0.06 in)
Impedance characteristics of
75 Ω, 4-terminal configuration,
Other specifications are the same
as for the 9261-10
Test Fixtures for SMDs
Applicable SMD size
3 : Measurable
s: May not be measurable depending on the
shape.
SMD type
JIS CODE
EIA CODE
0603
0201
1005
0402
1608
0603
2012
0805
3216
1206
3225
1210
4532
1812
5750
2220
Length L
Width W
0.60 mm (0.02 in)
1.00 mm (0.04 in)
1.60 mm (0.06 in)
2.00 mm (0.08 in)
3.20 mm (0.13 in)
3.20 mm (0.13 in)
4.50 mm (0.18 in)
5.70 mm (0.22 in)
0.30 mm (0.01 in)
0.50 mm (0.02 in)
0.80 mm (0.03 in)
1.25 mm (0.05 in)
1.60 mm (0.06 in)
2.50 mm (0.10 in)
3.20 mm (0.13 in)
5.00 mm (0.20 in)
9263
s
3
3
3
3
3
9677
s
3
3
s
9699
9143-10
3
3
s
s
3
3
3
3
3
3
SMD TEST FIXTURE 9677
Direct connection type, DC to 5 MHz,
Test sample dimensions:1 mm (0.04 in)
to 10 mm (0.39 in)
Direct connection type, For measuring
SMDs with electrodes on the side; DC
to 120 MHz, test sample dimensions:
3.5 mm ±0.5 mm (0.14 in ±0.02 in)
5.8
SMD TEST FIXTURE 9263
MAX: 10
0.7
DEPTH:
0.3
MAX: 4
MIN: 0.1
145
38
1
PINCHER PROBE 9143-10
Direct connection type, For measuring
SMDs with electrodes on the bottom; DC
to 120 MHz, test sample dimensions: 1.0
mm (0.04 in) to 4.0 mm (0.16 in) wide,
max. 1.5 mm (0.06 in) high
4
Cable length 1 m (3.28 ft), DC to 5
MHz, impedance characteristics of
50 Ω, 4-terminal pair configuration,
tip electrode spacing: 0.3 (0.01 in) to
6 mm (0.24 in)
PINCHER PROBE 9143
Impedance characteristics of
75 Ω, 4-terminal configuration, Other specifications are
the same as for the 9143-10
1
SMD TEST FIXTURE 9699
5
6
4
10
1150
Resistance Meters
High-precision portable resistance meter measures from µΩ to MΩ
RESISTANCE METER RM3548
marked
internal memory is recognized as a mass storage device when connected to a PC)
Memory storage
• Basic accuracy: 0.02%, Max. resolution: 0.1 μΩ, Max. measurable current: 1 A
• Measure from 0.0 µΩ (testing current 1 A) to 3.5 MΩ
• Easily record up to 1,000 data points in memory simply by applying the
instrument’s probes.
• Smoothly capture temperature-rise test data using interval measurement.
• Portable design is ideal for maintenance and testing of large equipment.
Power supply
Number of recordable data points: (manual/auto) Up to 1,000, (interval)
Up to 6,000; Interval: 0.2 to 10.0s (0.2s steps); Acquisition of data
from memory: display, USB mass storage (CSV, TXT files)
LR6 (AA) Alkaline batteries ×8, Continuous use: 10 hours (Under our
company’s conditions), Rated power consumption: 5 VA
Resistance
Meters
■ Basic specifications (Accuracy guaranteed for 1 year)
3 mΩ (3.5000 mΩ display Max., 0.1 µΩ resolution) to 3 MΩ range (3.5000
Resistance range MΩ display Max., 100 Ω resolution), 10 steps
Measurement accuracy: ±0.020 % rdg. ±0.007 % f.s.
[at 3 mΩ range] 1 A DC to [at 3 MΩ range] 500 nA DC
Testing current
Open-terminal voltage 5.5 V DC max.
Temperature
-10.0 to 99.9°C, accuracy: ±0.50°C (Temperature Sensor Z2002 and
RM3548 combined accuracy)
measurement
Measurement speed Fixed
Display refresh rate Without OVC: approx. 100ms, With OVC: approx. 230ms
Temperature correction, temperature conversion, offset voltage compensation (OVC), comparator (ABS/REF%), length conversion, judgment sound
Functions
setting, auto hold, auto power save (APS),
Averaging, panel store/panel load, USB communication interface (RM3548
Dimensions and mass 192 mm (7.56 in) W × 121 mm (4.76 in) H × 55 mm (2.17 in) D mm, 770 g (27.2 oz)
Clip type lead 9287-10 ×1, Temperature sensor Z2002 ×1, LR6 Alkaline
Accessories
battery ×8, Instruction manual ×1, USB Cable(A-to-mini B type) ×1,
Strap ×1, Spare fuse ×1
*The 9287-10, Z2002 are bundled with the RM3548
Measurement Lead
CLIP TYPE LEAD 9287-10
A:130 mm (5.12 in), B:83 mm (3.27 in),
L:1100 mm (3.61 ft), 70V DC
FOUR TERMINAL LEAD 9453
PIN TYPE LEAD 9465-10
TIP PIN 9465 -90
A:280 mm (11.02 in), B:118 mm (4.65 in), A: 80 mm (3.15 in) (red), 140 mm (5.51
in) (black, max. 550 mm (21.65 in)), B:
L:1360 mm (4.46 ft), 60V DC
121 mm (4.76 in), L: 1883 mm (6.18 ft)
To replace the tip on
the 9465-10
PIN TYPE LEAD 9772
A: 80 mm (3.15 in) (red), 140 mm (5.51
in) (black, max. 550 mm (21.65 in)), B:
118 mm (4.65 in), L: 1780 mm (5.84 ft)
TIP PIN 9772-90
To replace the tip on
the 9772
LARGE CLIP TYPE LEAD 9467
A:300 mm (11.81 in), B:116 mm (4.57 in),
L:1360 mm (4.46 ft), 50V DC, Not CE
marked
About probe length
100 mm (3.94 in)
ZERO ADJUSTMENT
BOARD 9454
For RM3544s/3545s/3548, 2 m (6.56 ft)
For the L2100, 9465-10, 9465, 9461
Case
TEMPERATURE
SENSOR Z2002
A: From junction to probe
B: Probe part
L: Whole length
LED COMPARATOR
ATTACHMENT L2105
CARRYING CASE
C1006
For the RM3548
Note: The L2101 to L2104 leads can be separated into two units, length A
is not noted
Featuring super-high accuracy and multi-channel capabilities (20 channels with 4-terminal measurement)
RESISTANCE METER RM3545, RM3545-01/-02
RM3545-01
marked
•0.006% basic accuracy, 0.01 μΩ max. resolution, 1A max. measurable current
•Measure from 0.00 μΩ (testing current 1 A) to 1200 MΩ
•Multiplexer Unit Z3003 (option) provides 20-channels of 4-terminal
measurements for a complete assessment of multi-point signals
(RM3545-02 only)
•Low-power resistance measurement with an open voltage not
exceeding 20 mV
•High-speed, comprehensive productivity support delivers decisions
in as little as 2.2 ms from start to finish
■ Basic specifications (Accuracy guaranteed for 1 year)
10 mΩ (12.00000 mΩ display Max., 10 nΩ resolution) to 1000 MΩ range
(1200.0 MΩ display Max., 100 kΩ resolution), 12 steps
Resistance range [LP ON] 1000 mΩ (1200.00 mΩ display Max., 10 µΩ resolution) to 1000 Ω
range (1200.00 Ω display Max., 10 mΩ resolution), 4 steps
Measurement accuracy: ±0.006 % rdg. ±0.001 % f.s.
1 A DC to 1 µA or less [LP ON] 1 mA to 5 μA DC
Testing current
20 V DC (10 kΩ range or more), 5.5 V DC max. (1000 Ω range or less)
Open-terminal voltage
[LP ON] 20 mV DC max.
-10.0 to 99.9 °C, accuracy: ±0.50 °C (Temperature Sensor Z2001 and RM3545
Temperature
combined accuracy), -99.9 to 999.9°C (analogue input)
measurement
Measurement speed FAST (2.2ms) / MED (50Hz: 21ms, 60Hz: 18ms) / SLOW1 (102ms) / SLOW2 (202ms)
Temperature correction, temperature conversion, offset voltage compensation
(OVC), comparator (ABS/ REF%), BIN, key-lock (OFF, menu lock, all lock), disFunctions
play digit count selection function (7- digit/ 6-digit/ 5-digit), automatic power supply frequency settings (AUTO/ 50Hz/ 60Hz), scaling, judgment sound setting,
auto hold, averaging, statistical calculations, panel store/panel load, D/A output.
[Only RM3545-02] Support unit: Z3003 (Install up to 2 units)
Multiplexer
Select from GP-IB (RM3545-01 only), RS-232C, PRINTER (RS-232C), or
Communication
USB . Remote function, communications monitor function, data output
interfaces
function, memory (50)
Power supply
100 to 240 V AC, 50/60 Hz, Rated power consumption: 40 VA
Dimensions and mass 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D
[RM3545/RM3545-01] 2.5 kg (88.2 oz), [RM3545-02] 3.2 kg (35.3 oz)
Power cord ×1, Clip type lead L2101 ×1, temperature sensor Z2001 ×1, Male EXT I/O connector
Accessories
×1, Instruction manual ×1, Application disc ×1, USB cable (A-to-B type) ×1, Spare fuse ×1
*The L2101, Z2001 are bundled with the RM3545 series
PIN TYPE LEAD L2102
For RM3544s/3545s, B:83 mm (3.27 in),
L:1.5 m (4.92 ft)
For RM3544s/3545s, B:140 mm (5.51 in),
L:1.5 m (4.92 ft)
PIN TYPE LEAD L2103
For RM3544s/3545s, B:138 mm (5.43 in),
L:1.5 m (4.92 ft)
About probe length
LED COMPARATOR
ATTACHMENT L2105
For RM3544s/3545s/3548, 2 m (6.56 ft)
A: From junction
to probe
B: Probe part
L: Whole length
Note: The L2101 to L2104 leads can be separated into two units,
length A is not noted
MULTIPLEXER UNIT Z3003
For RM3545-02, 4-wire 10ch or
2-wire 21ch input scanning
PC Communication
Measurement Lead / Input scanner
CLIP TYPE LEAD L2101
4 -TERMINAL LEAD L2104
TEMPERATURE SENSOR Z2001
For RM3544s/3545s, B:118 mm (4.65 in),
L:1.5 m (4.92 ft)
For RM3544s/3545s, 1.75 m (5.74 ft)
*The 9151-02 is only for the RM3545-01
RS-232C CABLE 9637
For the PC, 9pin - 9pin,
cross, 1.8m (5.91 ft) length
RS-232C CABLE 9638
GP-IB CONNECTOR CABLE
For the PC, 9pin - 25pin,
cross, 1.8m (5.91 ft) length 9151-02
2m (6.56 ft) length
39
Resistance Meters
Applications
Probes suited to DC measurement of the chassis
and bodies of large equipment
Large motors, large transformers
Temperature rise tests (Motors, choke coils, transformers)
RESISTANCE METER RM3548
High-precision portable resistance
meter, measures from µΩ to MΩ
4 -TERMINAL
LEAD 9453
CLIP TYPE LEAD 9287-10
PIN TYPE LEAD
9465-10
Resistance
Meters
Vehicle grounding lines, conductivity of aircraft fuselages
PIN TYPE LEAD 9772
LARGE CLIP TYPE LEAD 9467
Motors, solenoids, choke coils, transformers, wire harnesses
Probes suited to manual measurement on
production lines
RESISTANCE METER
RM3544 / RM3544-01
High-precision bench-top resistance
meter for both manual operation and
integration with automatic lines
Contacts, wire harnesses, relay contacts, switches
CLIP TYPE LEAD L2101
4 -TERMINAL LEAD L2104
PIN TYPE LEAD L2102
PIN TYPE LEAD L2103
Conductive rubber, paint
Fuses, resistors, heaters, wires, welds
High-precision bench-top resistance meter for both manual operation and integration with automatic lines
RESISTANCE METER RM3544, RM3544-01
RM3544-01
RM3544-01
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
30 mΩ (35.000 mΩ display Max., 1 µΩ resolution) to 3 MΩ range (3.5000
Resistance range MΩ display Max., 100 Ω resolution), 9 steps
Measurement accuracy: ±0.020 % rdg. ±0.007 % f.s.
[at 30 mΩ range] 300 mA DC to [at 3 MΩ range] 500 nA DC
Testing current
Open-terminal voltage 5.5 V DC max.
Temperature
-10.0 to 99.9°C, accuracy: ±0.50°C (Temperature Sensor Z2001 and
RM3544/RM35440-01 combined accuracy)
measurement
Measurement speed FAST (50Hz: 21ms, 60Hz: 18ms) / MED (101ms) / SLOW (401ms)
Display refresh rate N/A
Functions
•Basic accuracy: 0.02%, Max. resolution: 1 μΩ, Max. measurable current: 300 mA
•Measure from 0.000 mΩ (testing current 300 mA) to 3.5 MΩ
•Probe for guard jack use and increased measurement current yield an
instrument that’s more resistant to noise
•Optional LED COMPARATOR ATTACHMENT and high-volume judgment
tones combine to ensure PASS/FAIL judgments are communicated reliably
in the noisy environment of the production floor
•EXT I/O interface with NPN/PNP support can accommodate a variety of
automated production lines (-01 model)
Memory storage
Communication
interfaces
Power supply
Temperature correction, comparator (ABS/REF%), key-lock (OFF, menu
lock, all lock), display digit count selection function (5 digits/ 4 digits),
automatic power supply frequency settings (AUTO/50Hz/60Hz), scaling,
judgment sound setting, auto hold, averaging, panel store/panel load
N/A
[Only RM3544-01] Select from RS-232C, PRINTER (RS-232C), or USB
Remote function, communications monitor function, data output function
100 to 240 V AC, 50/60 Hz, Rated power consumption: 15 VA
Dimensions and mass 215 mm (8.46 in) W × 80 mm (3.15 in) H × 166 mm (6.54 in) D mm
[RM3544] 0.9 kg (31.7 oz), [RM3544-01] 1.0 kg (35.3 oz)
[RM3544] Power cord ×1, Clip type lead L2101 ×1, Instruction manual
×1, Spare fuse ×1
Accessories
[RM3544-01] Power cord ×1, Clip type lead L2101 ×1, Male EXT I/O
connector ×1, Instruction manual ×1, Application disc ×1, USB cable
(A-to-B type) ×1, Spare fuse ×1
*The L2101 is bundled with the RM3544 series
PIN TYPE LEAD L2102
For RM3544s/3545s, B:83 mm (3.27 in),
L:1.5 m (4.92 ft)
For RM3544s/3545s, B:140 mm (5.51 in),
L:1.5 m (4.92 ft)
About probe length
LED COMPARATOR
ATTACHMENT L2105
For RM3544s/3545s/3548, 2 m (6.56 ft)
40
A: From junction
to probe
B: Probe part
L: Whole length
Note: The L2101 to L2104 leads can be separated into two units,
length A is not noted
PIN TYPE LEAD L2103
For RM3544s/3545s, B:138 mm (5.43 in),
L:1.5 m (4.92 ft)
PC Communication
Measurement Lead / Input scanner
CLIP TYPE LEAD L2101
4 -TERMINAL LEAD L2104
TEMPERATURE SENSOR Z2001
For RM3544s/3545s, B:118 mm (4.65 in),
L:1.5 m (4.92 ft)
For RM3544s/3545s, 1.75 m (5.74 ft)
*For the RM3544-01
RS-232C CABLE 9637
RS-232C CABLE 9638
For the PC, 9pin - 9pin,
cross, 1.8m (5.91 ft) length
For the PC, 9pin - 25pin,
cross, 1.8m (5.91 ft) length
Resistance Meters
Resistance Meter for Ultra-low and Low Shunt Resistance
RESISTANCE HiTESTER RM3543, RM3543-01
■ Basic specifications (Accuracy guaranteed for 1 year) (Warm-up time 30 minutes or more)
Measurement method Four-terminal, constant-current DC
10 mΩ (Max. 12.00000 mΩ, 0.01 μΩ resolution) to 1000 Ω range (Max.
Resistance range
1200.000 Ω, 1 mΩ resolution), 7 steps
Monochrome graphic LCD 240 × 64 dot, white LED backlight
Display
[at 10 mΩ range, with SLOW mode, average 16 times settings]
Measurement
±0.060 % rdg. ±0.001 % f.s.
accuracy
[at 10 mΩ range] 1 A DC to [at 1000 Ω range] 1 mA DC
Testing current
RM3543-01
marked
Open-terminal
voltage
20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current
mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured
with a voltmeter having 10 MΩ)
Sampling rate
•±0.16% accuracy & 0.01μΩ resolution performance in automated systems
•Superb repeatable measurement accuracy
•Provide advanced contact-check, comparator, and data export functions
•Intuitive user interface and strong noise immunity are ideal for automated
systems
Test fixtures are not supplied with the unit. Select an optional test fixture when
ordering.
4-TERMINAL PROBE
9140
For RM3543, the 3532- DC to 100 kHz, impedance
80, DC to 1 MHz, 1 m
characteristics of 75 Ω,
(3.28 ft) length
4-terminal configuration
TEST FIXTURE 9262
SMD TEST FIXTURE 9263
Direct connection type,
DC to 5 MHz, measurable
conductor diameter: ø0.3
(0.01 in) to 2 mm (0.08 in)
Direct connection type,
DC to 5 MHz, Test sample
dimensions:1 mm (0.04 in) to
10 mm (0.39 in)
PC communication
Probe and Test fixtures
4-TERMINAL
PROBE 9500
RS-232C CABLE 9637
RS-232C CABLE 9638
For the PC, 9pin - 9pin,
cross, 1.8m (5.91 ft)
length
For the PC, 9pin - 25pin,
cross, 1.8m (5.91 ft)
length
Resistance
Meters
FAST, MEDIUM, SLOW, 3 settings
[at 10 mΩ range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC,
Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60
Integration time
Hz Note: PLC = one power line cycle (mains wave-form period)
Comparator (compare setting value with measurement value), Delay, OVC
(offset voltage compensation), Average, Measurement fault detection, Probe
short-circuit detection, Improve contact, Current mode setting (A pulse
application
function that applies current only during measurement), AutoOther functions
memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger
function. etc,.
External I/O, RS-232C, Printer, GP-IB (Model RM3543-01)
Interfaces
Trigger, Hold input, Comparator output, Settings monitor terminal, Service
External I/O
power output +5V, +12V, etc.
100 to 240 V AC, 50/60 Hz, 40 VA max.
Power supply
Dimensions and mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz)
Power cord ×1, EXT I/O male connector ×1, Instruction manual ×1,
Accessories
Operation guide ×1
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
Measure in as little as 0.9 ms, Optimized for Automated Systems
RESISTANCE HiTESTER RM3542, RM3542-01
■ Basic specifications (Accuracy guaranteed for 1 year) (Warm-up time 30 minutes or more)
Resistance range
RM3542-01
marked
•High speed and accuracy maximize productivity in automated systems
•Multiple checking functions ensure proper contact for reliable measurements
•Low-power resistance mode measures chip inductors and EMC suppression components
•Supports sample inspections during the manufacturing process
Test fixtures are not supplied with the unit. Please select an optional test fixture when
ordering
[at Low Power OFF] 100 mΩ range (Max. 120.0000 mΩ, 0.1 μΩ resolution) to
100 MΩ range (Max. 120.0000 MΩ, 100 Ω resolution), 10 steps
[at Low Power ON] 1000 mΩ range (Max. 1200.000 mΩ, 1 μΩ resolution) to
1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 4 steps
Display
Measurement
accuracy
Testing current
Open-terminal
voltage
Sampling rate
Measurement
times
Monochrome graphic LCD 240 × 64 dot, white LED backlight
[with SLOW mode, at 100 mΩ range] ±0.015 % rdg. ±0.002 % f.s.
[with SLOW mode, at 1000 Ω range] ±0.006 % rdg. ±0.001 % f.s. (the best case)
[at 100 mΩ range] 100 mA DC to [at 100 MΩ range] 100 nA DC
Integration time
0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz
20 V DC max.
FAST, MEDIUM, SLOW, 3 settings
[at 100 Ω /1000 Ω ranges, with Low Power OFF]
FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time)
Note: PLC = one power line cycle (mains wave-form period)
Comparator (compare setting value with measurement value), Delay (set to allow
Other functions
Interfaces
External I/O
Power supply
Dimensions and mass
Accessories
for mechanical delay of trigger input and probing, or set to allow for measurement object response), OVC (offset voltage compensation), Measurement fault
detection, Probe short-circuit detection, Improve contact, Auto-memory,
Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
RS-232C, Printer, GP-IB (Model RM3542-01)
Trigger, Hold input, Comparator output, Settings monitor terminal
100 to 240 V AC, 50/60 Hz, 30 VA max.
260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg
(102.3 oz)
Power cord ×1, EXT I/O male connector ×1, Instruction manual ×1,
Operation guide ×1
Other options refer to the detailed catalog
DC to 100 kHz, impedance
characteristics of 75 Ω,
4-terminal configuration
TEST FIXTURE 9262
SMD TEST FIXTURE 9263
Direct connection type,
DC to 5 MHz, measurable
conductor diameter: ø0.3
(0.01 in) to 2 mm (0.08 in)
Direct connection type,
DC to 5 MHz, Test sample
dimensions:1 mm (0.04 in) to
10 mm (0.39 in)
PC communication
Probe and Test fixtures
4-TERMINAL PROBE
9140
RS-232C CABLE 9637
RS-232C CABLE 9638
For the PC, 9pin - 9pin,
cross, 1.8m (5.91 ft)
length
For the PC, 9pin - 25pin,
cross, 1.8m (5.91 ft)
length
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
41
Resistance Meters
Wide measurement range & high-resolution, Optimized for Automated Systems
RESISTANCE HiTESTER 3541
■ Basic specifications (Accuracy guaranteed for 1 year)
Not CE Marked
cheduled
Discontinue s
Resistance range
20 mΩ range (Max. 20.0000 mΩ, 0.1 μΩ resolution) to 100 MΩ range (Max.
110.000 MΩ, 1 kΩ resolution), 11 steps
[at Low Power ON] 2 Ω range (Max. 2.00000 Ω, 10 μΩ resolution) to 2 kΩ
range (Max. 2.00000 kΩ, 10 mΩ resolution), 4 steps
Measurement
accuracy (SLOW 2)
Testing current
Open-terminal
voltage
±0.007 % rdg. ±0.0015 % f.s. dgt. (at 2 k/ 20 kΩ range)
[at Low Power ON] ±0.011 % rdg. ±0.01 % f.s. (at 2 to 2 kΩ range)
100 nA to 1 A DC, [at Low Power ON] 10 μA to 10 mA DC
5 V DC (at 20/ 200mΩ range), 2.6 V DC (at 2 to 20kΩ range), 13 V DC (at
100kΩ to 100MΩ range), [at Low Power ON] 60 mV DC
Sampling rate
Resistance
Meters
Delay = 0ms, TC off,
Statistics operation off,
Offset voltage revise off
•0.1 µΩ (20 mΩ range) to 110.000 MΩ wide measurement range,
•High speed & high precision measurements - as fast as 0.6 ms with 70
ppm precision (in the 2 kΩ to 110 kΩ range)
•Two types of temperature correction - by Pt sensor or infrared thermometer
•Equipped with EXT I/O, GP-IB and RS-232C interfaces for easy integration into automated production lines
The Clip Type Lead 9287-10 is bundled with the instrument. For other test fixtures,
purchase the appropriate lead option for your application separately.
FAST
MIDIUM
SLOW 1
SLOW 2
50 Hz
0.6 ms ± 0.3 ms
21 ms ± 1 ms
155 ms ± 5 ms
455 ms ± 10 ms
60 Hz
0.6 ms ± 0.3 ms
17 ms ± 1 ms
149 ms ± 5 ms
449 ms ± 10 ms
Response time (at truely resistance) : the above time plus approx. 1 ms
(different at setting condition, or testing target)
Temperature measurement (-10.0 to 99.9 ˚C), Revised resistance with temperature, Revised temperature with inductor resistance, Comparator,
Settings save & load (Max. 30 settings), Classification measurement (BIN
function), Statistics operation, Offset voltage revise, Delay, Average function
Other functions
Interfaces
RS-232C and GP-IB (standard)
[Output] BCD, End of measurement, Comparator result, BIN result, NG,
with open collector output
External I/O
[Input] Select setting, Trigger, Calibration, Zero-adjust, Print, with C-MOS
level
100 to 240 V AC, 50/60 Hz, 30 VA max.
Power supply
Dimensions and mass 215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.6 kg (91.7 oz)
Clip type lead 9287-10 ×1, Temperature probe 9451 ×1, Instruction manual
Accessories
×1, Power cord ×1, EXT I/O Male connector ×1
About probe length
A: From junction to probe
B: Probe part
L: Whole length
Note: The 9455 is a precision
instrument. Exercise appropriate
care when handling it.
23mm
φ 5mm
Voltage side
0.2mm / φ 0.2
PIN TYPE LEAD 9455
ZERO ADJUSTMENT
BOARD 9454
For the L2100, 9465-10, 9465,
9461
A:260 mm (10.24 in), B:136 mm (5.35 in), L:890
mm (2.92 ft), Not CE marked
FOUR TERMINAL
LEAD 9453
A:280 mm (11.02 in), B:118
mm (4.65 in), L:1360 mm
(4.46 ft), 60V DC
Tip φ29 mm
(1.14 in)
Current side
φ 2.8mm
CLIP TYPE LEAD 9452
φ 2mm
1.8 mm dia. single-axis
type for measuring small
electrodes
0.2 mm parallel pyramid-type
pins for measuring at thru holes
and sub-millimeter objects
Voltage
side
A:220 mm (8.66 in), B:197 mm 9452 tip shape
(7.76 in), L:1360 mm (4.46 ft)
PIN TYPE LEAD 9770
PIN TYPE LEAD 9771
A:260 mm (10.24 in), B:140 mm (5.51 in),
L:850 mm (2.79 ft), 70V DC
A:260 mm (10.24 in), B:138 mm (5.43 in),
L:850 mm (2.79 ft), 70V DC
The 9451 is bundled for the 3541
Voltage side
2
10mm
Measurement Lead
6mm
14mm
φ 0.8mm
Current side
Current
side
LARGE CLIP TYPE LEAD 9467
A:300 mm (11.81 in), B:116 mm (4.57 in),
L:1360 mm (4.46 ft), 50V DC, Not CE
marked
PIN TYPE LEAD 9461
A:240 mm (9.45 in), B:132 mm
(5.20 in), L:804 mm (2.64 ft)
φ1.4mm
9461 tip shape
TEMPERATURE PROBE
9451
Platinum resistance, 1.5m (4.92ft)
length
CONNECTION CABLE
9300
For multipolar connectors,
1.5m (4.92ft) length
PC communication
42
CLIP TYPE LEAD 9287-10
A:130 mm (5.12 in), B:83 mm (3.27 in),
L:1100 mm (3.61 ft), 70V DC
RS-232C CABLE 9637
RS-232C CABLE 9638
For the PC, 9pin - 9pin,
cross, 1.8m (5.91 ft)
length
For the PC, 9pin - 25pin,
cross, 1.8m (5.91 ft)
length
GP-IB CONNECTOR
CABLE 9151-02
2 m (6.56 ft) length
Battery Testers
High-speed measurement from large-cell to high-voltage battery testing
BATTERY HiTESTER BT3563, BT3562
BT3563-01,BT3562-01
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
BT3563/BT3563-01
BT3562/BT3562-01
± 300V DC rated input voltage
± 60V DC rated input voltage
Max. applied
measurement voltage ± 300V DC Max. rated voltage to earth ± 70V DC Max. rated voltage to earth
3mW (Max. display 3.1000mW, resolution 0.1mW) to 3000W (Max. display
3100.0W, resolution 100mW), 7 ranges
Accuracy: 30mW to 3000W ranges, ± 0.5%rdg. ± 5dgt. (Add ± 3dgt. for
Resistance
Measurement
ranges
•Measure high-voltage battery packs up to 300V (BT3563)
•Production line testing of high-voltage battery packs and battery
modules
•Large (low-resistance) cell testing
•Choice of PC interfaces for full remote operation
Display
Sampling rate
Measurement time
Note: The comparison threshold values depend on the battery manufacturer, type, and
capacity, and these must be established by the user.
FAST, or ± 5dgt. for MEDIUM)
Testing source frequency: 1kHz ± 0.2Hz, testing current: 100mA (3mW
range) to 10mA (3000W range)
Open-circuit Voltage: 25V peak (3/30mW ranges), 7V peak (300mW range),
4V peak (3W to 3000W ranges)
DC 6V (resolution 10mV) to DC 300V DC 6V (resolution 10mV) to DC 60V
(resolution 1mV), 3 ranges
(resolution 100mV), 2 ranges
Accuracy: ± 0.01%rdg. ± 3dgt. (Add ± 3dgt. for EX.FAST, or ± 2dgt. for FAST
Battery Testers
Voltage
Measurement
ranges
EX.FAST, or ± 2dgt. for FAST and MEDIUM)
3mW range, ± 0.5%rdg. ± 10dgt. (Add ± 30dgt. for EX.FAST, or ± 10dgt. for
and MEDIUM)
31000 full digits (resistance), 600000 full digits (voltage), LED
Four steps, 4ms (Extra-FAST), 12ms (FAST), 35ms (Medium), 150ms (Slow)
(Typ., sampling time depends on supply frequency settings and function.)
Response time + sampling rate, approx. 10ms for measurements
(Response time depends on reference values and the measurement object.)
Judgment result: Hi/IN/Lo (resistance and voltage judged independently)
Setting: Upper and lower limit, Deviation (%) from reference value
Logical ANDed result: PASS/FAIL, calculates the logical AND of resistance and
voltage judgment results.
Result display, beeper, or external I/O output, Open-collector (35 V, 50 mA DC max.)
Measured resistance (displayed value, from 0 to 3.1V DC, -01 suffix models only)
Analog Output
External I/O, RS-232C, Printer (RS-232C), GP-IB(-01 suffix models only)
Interfaces
100 to 240V AC, 50/60Hz, 30VA max.
Power supply
Dimensions and mass 215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.4 kg (84.7 oz)
Instruction manual ×1, Power cord ×1
Accessories
Comparator
functions
• Measurement leads are not included. Purchase the appropriate lead option for your
application separately.
• The male (system side) of the EXT I/O connector is also available. Please inquire with your
HIOKI distributor.
For high-speed production line testing of small battery packs
BATTERY HiTESTER 3561, 3561-01
■ Basic specifications (Accuracy guaranteed for 1 year)
±22 V DC
Max. applied
measurement voltage ±70 V DC maximum rated voltage above ground
300 mΩ (Max. display 310.00 mΩ, resolution 10 μΩ) to 3 Ω (Max. display 3.1000
Ω, resolution 100 μΩ), 2 ranges
Accuracy: ±0.5 % rdg. ±5 dgt. (Add ±3 dgt. for EX.FAST, or ±2 dgt. for FAST
Resistance
and MEDIUM)
Measurement
Testing source frequency: 1 kHz ±0.2 Hz, testing current: 10 mA (300 mΩ
ranges
range), 1 mA (3 Ω range)
Open-circut Voltage: 7 V peak
Voltage Measurement DC 20 V, resolution 0.1 mV, Accuracy: ±0.01 % rdg. ±3 dgt. (Add ±3 dgt. for
EX.FAST, or ±2 dgt. for FAST and MEDIUM)
ranges
31000 full digits (resistance), 199999 full digits (voltage), LED
Display
Four steps, 4 ms (Extra-FAST), 12 ms (FAST), 35 ms (Medium), 150 ms (Slow)
Sampling rate
3561-01
marked
(Typ., sampling time depends on supply frequency settings and function.)
Measurement time
•High-speed testing for production lines of small battery packs for
mobile and portable communications devices
•Measure internal resistance and battery voltage
•For process control such as in high-speed automated assembly lines
Response time + sampling rate, approx. 3 ms for measurements
(Response time depends on reference values and the measurement object.)
Judgment result: Hi/IN/Lo (resistance and voltage judged independently)
Setting: Upper and lower limit, Deviation (%) from reference value
Logical ANDed result: PASS/FAIL, calculates the logical AND of resistance and
voltage judgment results.
Result display, beeper, or external I/O output, Open-collector (35 V, 50 mA DC max.)
External I/O, RS-232C, Printer (RS-232C), GP-IB (-01 suffix models only)
Interfaces
100 to 240 V AC, 50/60 Hz, 30 VA max.
Power supply
Dimensions and mass 215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.4 kg (84.7 oz)
Instruction manual ×1, Power cord ×1
Accessories
Comparator
functions
Note: The comparison threshold values depend on the battery manufacturer, type, and
capacity, and these must be established by the user
• Measurement leads are not included. Purchase the appropriate lead option for your
application separately.
• The male (system side) of the EXT I/O connector is also available. Please inquire with your
HIOKI distributor.
BT3563/3562, 3561series common options
A:300 mm (11.81 in), B:172 mm (6.77 in),
L:1400 mm (4.59 ft), for high voltage
battery measurements, 600 V DC max.,
BT3563, BT3562 only
ZERO ADJUSTMENT
BOARD 9454
For the L2100, 9465-10, 9465,
9461
PC communication
PIN TYPE LEAD L2100
Zero adjustment board
Measurement lead (for measuring high voltage batteries with Models BT3563 and BT3562)
RS-232C CABLE 9637 RS-232C CABLE 9638 GP-IB CONNECTOR
For the PC, 9pin - 9pin,
For the PC, 9pin - 25pin,
CABLE 9151-02
cross, 1.8m (5.91 ft) length
Measurement leads (for measuring batteries up to 60 V with BT3563, BT3562, or 3561)
1.8 mm dia. single-axis type for measuring small electrodes
0.2 mm parallel pyramid-type pins for measuring at thru holes and sub-millimeter objects
CLIP TYPE LEAD 9287-10 FOUR TERMINAL
A:130 mm (5.12 in), B:83 mm
LEAD 9453
PIN TYPE LEAD 9770
9770 tip shape
A:260 mm (10.24 in), B:140 mm (5.51 in),
L:850 mm (2.79 ft), 70V DC
PIN TYPE LEAD 9771
9771 tip shape
A:260 mm (10.24 in), B:138 mm (5.43 in),
L:850 mm (2.79 ft), 70V DC
(3.27 in), L:1100 mm (3.61 ft), 70V A:280 mm (11.02 in), B:118
DC
mm (4.65 in), L:1360 mm
(4.46 ft), 60V DC
cross, 1.8m (5.91 ft) length 2 m (6.56 ft) length
Tip φ29 mm
(1.14 in)
LARGE CLIP TYPE
LEAD 9467
A:300 mm (11.81 in), B:116
mm (4.57 in), L:1360 mm
(4.46 ft), 50V DC, Not CE
marked
About probe length
A: From junction to probe
B: Probe part
L: Whole length
43
Battery Testers
Instantaneously diagnose battery degradation
BATTERY HiTESTER 3555
marked
Battery Testers
•For use with compact batteries such as nicad and nickel-metal hydride
•Instantaneously diagnoses degradation (PASS, CAUTION, FAIL) by measuring internal resistance and voltage.
*Operator must input the criteria for PASS/FAIL judgments according to the type of battery
being measured.
The 3555 is unable to make PASS/FAIL judgments for lithium-ion batteries due to the extremely
small magnitude of the changes in their internal resistance. For applications involving
measurement of batteries with low internal resistance, for example lead acid batteries, use the
Battery HiTester 3554.
■ Basic specifications (Accuracy guaranteed for 1 year)
300 mΩ (Max. display 300.00 mΩ, resolution 100 μΩ) to 30 Ω (Max. display
30.00 Ω, resolution 10 mΩ), 3 ranges
Accuracy: ±0.8 % rdg. ±6 dgt. (All ranges)
Resistance
Measurement range Testing source frequency: 1 kHz ±5 Hz, testing current: 5 mA (300 mΩ
range), 500 μA (3 Ω range), 50 μA (30 Ω range)
Open-circut Voltage: 5 V peak
± 3 V (Max. display ±3.000 V, resolution: 1 mV) to ± 30 V (Max. display ±30.00 V,
Voltage
resolution: 10 mV), 2 ranges
Measurement range
Accuracy: ±0.1 % rdg. ±6 dgt.
Absolute Max. input
50 V DC max. (No AC input)
voltage
1.25 times/s (at resistance and voltage measurement combination)
Sampling rate
Setting: Upper and lower limit for resistance, and lower limit for voltage,
Number of comparator setting: 10 sets
Comparator
Comparator output: Pass (green), Warning (amber), and Fail (red) LEDs,
functions
Audible output on warning or Fail
Data storage: N/A, Interface: N/A, Temperature measurement: N/A
Other
LR6 (AA) Alkaline dry battery ×6, Continuous operating time: 18 h
Power supply
Dimensions and
196 mm (7.72 in)W × 130 mm (5.12 in)H × 50 mm (1.97 in)D, 680 g (24.0 oz)
(including batteries)
mass
Pin type lead 9461 ×1, Instruction manual ×1, LR6 (AA) alkaline battery × 6
Accessories
10
φ 2.8
A:240 mm (9.45 in), B:132
mm (5.20 in), L:804 mm
(2.64 ft)
2
Voltage side
φ 1.4
9461 tip shape
23
φ5
CLIP TYPE LEAD 9452
A:220 mm (8.66 in), B:197
mm (7.76 in), L:1360 mm
(4.46 ft)
φ2
ZERO ADJUSTMENT
BOARD 9454
FOUR TERMINAL LEAD
9453
For the L2100, 9465-10,
9465, 9461
A:280 mm (11.02 in), B:118 mm
(4.65 in), L:1360 mm (4.46 ft),
60V DC
Current
side
Voltage
side
CLIP TYPE LEAD 9287-10
A:130 mm (5.12 in), B:83 mm
9452 tip shape (3.27 in), L:1100 mm (3.61 ft), 70V
DC
Carrying case
Measurement Lead
PIN TYPE LEAD 9461
A: From junction to probe
B: Probe part
L: Whole length
About
probe length
Current side
CARRYING CASE
9382
For the 3555, 3550
Primarily for use with compact secondary batteries, etc. (for terminals with very little surface area)
1.8 mm dia. single-axis type for measuring small electrodes
PIN TYPE LEAD 9770
9770 tip shape
A:260 mm (10.24 in), B:140 mm (5.51 in),
L:850 mm (2.79 ft), 70V DC
0.2 mm parallel pyramid-type pins for measuring at thru holes and sub-millimeter objects
PIN TYPE LEAD 9771
9771 tip shape
A:260 mm (10.24 in), B:138 mm (5.43 in),
L:850 mm (2.79 ft), 70V DC
Medium-size and large lead acid battery tester ideal for diagnosing UPS batteries
BATTERY HiTESTER 3554
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
3 mΩ (Max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (Max. display 3.100 Ω, resolution
1 mΩ), 4 ranges
Resistance
Accuracy: ±0.8 % rdg. ±6 dgt. (3 mΩ range: ±1.0 % rdg. ±8 dgt.)
Measurement range
Testing source frequency: 1 kHz ±30 Hz, testing current: 150 mA (3m/30 mΩ
range), 15 mA (300 mΩ range), 1.5 mA (3 Ω range), Open-circuit Voltage: 5 V peak
± 6 V (Max. display ±6.000 V, resolution: 1 mV) to ± 60 V (Max. display ±60.00
Voltage
Measurement range V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg. ±6 dgt.
Absolute Max. input
60 V DC max. (No AC input)
voltage
1 time/s (at resistance, voltage, and temperature measurement combination)
Sampling rate
Setting: First and second resistance limits, and lower voltage limit, Number
Comparator
of comparator setting: 200 sets
functions
Comparator output: LCD display of PASS, WARNING, or FAIL. (Select
beeper to sound on PASS/WARNING or FAIL)
Data storage
•Measurement circuit that's more resistant to noise than previous models
•Instantaneously diagnoses degradation (PASS, CAUTION FAIL) by measuring internal resistance and voltage
•Increased measurement efficiency thanks to new compact, lightweight
probes
•Store up to 4,800 data points in built-in memory and transfer to PC via
USB
Max. storable data: 4800 sets. (Saved items: Date, time, resistance value, voltage value, temperature, comparator setting values, and comparator judgement.)
Temperature measurement (-10.0 to 60.0 °C), USB interface (includes
dedicated software for transferring data to a PC), Averaging, Zero-adjustment,
Other functions
Hold, Auto-hold, Auto-memory, Auto-power-save, Clock
LR6 (AA) Alkaline dry battery ×8, Continuous operating time: 10 h
Power supply
Dimensions and mass 192 mm (7.56 in)W × 121 mm (4.76 in)H × 55 mm (2.17 in)D, 790 g (27.9 oz) (including batteries)
Pin type lead 9465-10 ×1, USB cable ×1, Application software CD ×1, Strap
× 1, Instruction manual ×1, Carrying case ×1, Zero adjustment board ×1,
Accessories
LR6 alkaline batteries ×8, Fuse ×1
The thresholds for determining the pass/fail condition of a battery depends on the specifications and standards
of the battery manufacturer, battery type, capacity, etc. It is important and necessary to always conduct battery
testing against the internal resistance and terminal voltage of a new or reference battery. In some cases, it
may be difficult to determine the deterioration state of sealed lead acid batteries which demonstrates smaller
changes in internal resistance than traditional open type (liquid) lead-acid or alkaline batteries.
Other options refer to the detailed catalog
Primarily for use with lead acid batteries, etc.
Easy 4-terminal measurement, 2.7 mm dia.
single-axis type
Measurement Lead
44
Large angle of probe application, 2.5 mm
pitch 2-axis pin type
About probe length
A: From junction to probe
B: Probe part
L: Whole length
ZERO ADJUSTMENT
BOARD 9454
For the L2100, 9465-10, 9465, 9461
Tip φ29 mm
(1.14 in)
PIN TYPE LEAD 9465-10 TIP PIN 9465-90
PIN TYPE LEAD 9772
TIP PIN 9772-90
A: 80 mm (3.15 in) (red), 140
To replace the tip on the A: 80 mm (3.15 in) (red), 140 mm To replace the tip on
mm (5.51 in) (black, max. 550
9465-10
the 9772
(5.51 in) (black, max. 550 mm
mm (21.65 in)), B: 121 mm (4.76
(21.65 in)), B: 118 mm (4.65 in), L:
in), L: 1883 mm (6.18 ft)
1780 mm (5.84 ft)
LARGE CLIP TYPE LEAD 9467 REMOTE CONTROL
A:300 mm (11.81 in), B:116 mm (4.57 in), SWITCH 9466
L:1360 mm (4.46 ft), 50V DC, Not CE
marked
Use with the 9465 (for the
3554, 3551, 3560)
CLIP TYPE LEAD WITH
TEMPERATURE SENSOR 9460
For the 3540, 3554, A:300 mm (11.81 in),
B:106 mm (4.17 in), L:2268 mm (7.44 ft)
Super Meg-ohm Testers
Test System Ideal for MLCC Leakage Current Measurement
SUPER MΩ HiTESTER SM7810, SM7810-20
Not CE Marked
■ Basic specifications (Accuracy guaranteed for 1 year, warm-up time 1 hour or more)
Number of channels 8 channels (parallel and simultaneous measurement)
Supply voltage from external power source (voltage input terminal on the rear panel)
Applied voltage
Current: 1 pA to 1 mA,
Measurement
Ranges: 100 pA/ 1 nA/ 10 nA/ 100 nA/ 1 µA/ 10 µA/ 100 µA/ 1 mA
range
Resistance: 1 × 102 Ω to 1 × 1015 Ω
Measurement speed
FAST: 6.8 ms, MED: 26.0 ms, SLOW: 100.0 ms, SLOW2: 320.0 ms
INDEX typical time
Current accuracy: ±(2.0+ (0.5 µA / (Measured current value)) ) %
Resistance accuracy: Current accuracy + Voltage generation accuracy
of external power supply
(1µA range, FAST)
Testing voltage setting 0.1 V to 1000.0 V (Resolution: 0.1 V)
Judges the contact state by comparing the measured capacitance to a
Contact check
reference value
Trigger delay, averaging, contact check, jig capacity open correction,
Measured value comparison and judgment, jig resistance open correcOther functions
tion functions
GP-IB, RS-232C, EXT I/O
Interfaces
SM7810: AC 100 V/110 V, 50/60 Hz, 30 VA
Power supply
SM7810-20: AC 220 V, 50/60 Hz, 30 VA
Dimensions and mass 425 mm (16.73 in) W × 99 mm (3.90 in) H × 488 mm (19.21 in) D, 10.5 kg (370.4 oz)
Power cord ×1, Voltage input connector ×1, Spare fuse (built into inlet)
Accessories
×1, Rubber feet ×4, Instruction manual ×1
Basic measurement
accuracy
PC communication
The Super MΩ HiTester SM7810 is produced to order. An input/output terminal connection
cable*1 is required separately. Please contact your local HIOKI distributor.
*1 Input/output terminal connector/plug and connection cable
• Current input terminal connector and voltage output terminal plug are not included. Voltage
input terminal connector is included.
• Input/output terminal connection cables are available in various lengths to suit HIOKI
measurement systems. Please consult with your HIOKI distributor.
RS-232C CABLE 9637
RS-232C CABLE 9638
Super Meg-ohm
Testers
•Test the leakage current of MLCCs at the fastest speed of 6.8ms simultaneously over 8 channels
•Conduct high-speed leakage current testing of large-capacity MLCCs in the
high current range (1mA)
•Improve testing reliability using the contact check function
•Build a flexible system by making best use of the individual settings of each
channel
GP-IB CONNECTOR
For the PC, 9pin - 9pin,
For the PC, 9pin - 25pin,
CABLE 9151-02
cross, 1.8m (5.91 ft) length cross, 1.8m (5.91 ft) length 2 m (6.56 ft) length
The Power Source Unit Ideal for MLCC Leakage Current Measurement
POWER SOURCE UNIT SM7860 series
•Support for multi-channel systems up to 32-channel output
•8-channels or 16-channels dual-line output voltage setting
•Positive and negative polarities required for the MLCC test line included in a
single unit
•Output ON/OFF and current limitation can be performed for each channel
•Support for the discharge of the charge capacitor
•Output voltage of 1 kV is available
•Large current output of 50 mA */channel allows for reducing the number of
backup charges
Not CE Marked
* Output voltage of 1 kV is limited to 10 mA/channel
■ Basic specifications (Accuracy guaranteed for 1 year, warm-up time 1 hour or more)
Supported Device
Generation
accuracy
Interfaces
Combination example of the SM7610
Power supply
Super MΩ HiTester SM7810
Object to which voltage is applied: MLCC (the Multilayer Ceramic Capacitor)
Output voltage accuracy: ±2% of set value ± 0.5 V (with no load)
Inter-channel error: ± 0.01 V or less (between outputs on the same line with no load)
GP-IB, RS-232C, EXT I/O
SM7860-01 to -07: 100 V AC, SM7860-21 to -27: 220 V AC, 50/60 Hz,
860 VA
425 mm (16.73 in) W × 249 mm (9.80 in) H × 581 mm (22.87 in) D, 45 kg
Dimensions and mass (1587.3 oz)
[SM7860-07 / -27] : 32 kg (1128.7 oz)
Power cable ×1, Instruction manual ×1, Voltage output connector ×4
Accessories
[SM7860-01, 02, 21, 22] : ×2
The Power Source Unit SM7860 is produced to order. The SM7860 allows for setting
the dual-line output voltage on 8 channels or 16 channels, and enables up to 32-channel
output. Select a power source unit combining positive and negative power source (1 kV/500
V), discharge, and low-voltage power source (10 V) modules to build a power source ideal
for the leakage current test system.
Functions & output channel configuration
SM7860-XX*2
OUT1 to 4
output content
-05 / -25
-06 / -26
OUT1
OUT2 +500V
-01 / -21
+1kV
+500V +500V
+1kV
+1kV
+500V discharge
+1kV discharge
+10V
OUT3
OUT4
-1kV
-500V
-1kV
-1kV
-500V discharge
-1kV
+10V discharge
Overview (Total number of
channels and output voltage)
Number of OUT1 channels
1
OUT1 output voltage range *
Number of OUT2 channels
Line A
1
OUT2 output voltage range *
Current limitation
2
Maximum output current *
Number of OUT3 channels
1
OUT3 output voltage range *
Number of OUT4 channels
Line B
1
OUT4 output voltage range *
Current limitation
2
Maximum output current *
-500V
-02 / -22
-03 / -23
-500V
-04 / -24
discharge
-07 / -27
+10V
16 ch
±500 V
16 ch
±1000 V
32 ch
±500 V
32 ch
±1000 V
32 ch
±500 V, discharge
32 ch
±1000 V, discharge
32 ch
10 V, discharge
8 ch
1.0 V to 500.0 V
8 ch
250.0 V to 1000.0 V
−−
−−
±50 mA/ch
430 mA (200 VA)
±10 mA/ch
100 mA (100 VA)
8 ch
1.0 V to 500.0 V
8 ch
1.0 V to 500.0 V
±50 mA/ch
430 mA (200 VA)
8 ch
250.0 V to 1000.0 V
8 ch
250.0 V to 1000.0 V
±10 mA/ch
100 mA (100 VA)
8 ch
1.0 V to 500.0 V
8 ch
discharge
±50 mA/ch
430 mA (200 VA)
8 ch
250.0 V to 1000.0 V
8 ch
discharge
±10 mA/ch
100 mA (100 VA)
8 ch
1.0 V to 10.0 V
8 ch
1.0 V to 10.0 V
±50 mA/ch
430 mA (200 VA)
8 ch
-1.0 V to -500.0 V
8 ch
-250.0 V to -1000.0 V
−−
−−
±50 mA/ch
430 mA (200 VA)
±10 mA/ch
100 mA (100 VA)
8 ch
-1.0 V to -500.0 V
8 ch
-1.0 V to -500.0 V
±50 mA/ch
430 mA (200 VA)
8 ch
-250.0 V to -1000.0 V
8 ch
-250.0 V to -1000.0 V
±10 mA/ch
100 mA (100 VA)
8 ch
-1.0 V to -500.0 V
8 ch
discharge
±50 mA/ch
430 mA (200 VA)
8 ch
-250.0 V to -1000.0 V
8 ch
discharge
±10 mA/ch
100 mA (100 VA)
8 ch
1.0 V to 10.0 V
8 ch
discharge
±50 mA/ch
430 mA (200 VA)
*1 The resolution of the output voltage range is 0.1 V.
*2 Only when the operating conditions as stated in the restriction warnings of the specifications are met.
45
Super Meg-ohm Testers
High-speed and High-precision measurement of super megohm or very small current
DIGITAL SUPER MEGOHMMETER DSM-8104
Not CE Marked
■ Basic specifications (Accuracy guaranteed for 1 year)
Number of channels 1 ch
10 pA range (0.1 fA resolution), Accuracy: ±(3.0 % of rdg. +1.2 % of range)
100 pA range (1.0 fA resolution), Accuracy: ±(1.5 % of rdg. +0.6 % of range)
1 nA range (10 fA resolution), Accuracy: ±(0.6% of rdg. +0.6% of range)
10 nA range (100 fA resolution), Accuracy: ±(0.4 % of rdg. +0.5 % of range)
100 nA range (1 pA resolution), Accuracy: ±(0.4 % of rdg. +0.5 % of range)
DC Current
1 μA range (10 pA resolution), Accuracy: ±(0.4 % of rdg. +0.5 % of range)
Measurement
10 μA range (100 pA resolution), Accuracy: ±(0.4 % of rdg. +0.5 % of range)
100 μA range (1 nA resolution), Accuracy: ±(0.4 % of rdg. +0.5 % of range)
Super Meg-ohm
Testers
(1) With 300 ms measurement time, with averaging processing enabled
(2) At a temperature of 23 °C ±5 °C with humidity of 85% rh
(3) After self-calibration (1 min. interval)
(4) With averaging processing enabled
•Measures insulation resistance of capacitive/highly insulated materials at
high speed with high accuracy
•Resistance measurement range : 1 x 10 3 to 3 x 1016 Ω
•Small current measurement: 0.1 fA to 10 mA
•Testing voltage: 0.1 V DC to 1000 V DC
•Histogram display of selected results
•Compatible for measurement of several sample types with electrodes & other
devices
Note: RS-232C connection cable: The optional RS-232C Cable 9637 cannot be used with
this product. Use a cross cable for connections as described in the instruction manual.
Resistance
1 × 103 Ω to 3 × 1016 Ω (Open-circuit), (Measurement time is 300 ms)
Measurement
Note: Resistance measurement accuracy is defined by the current range accuracy
and voltage setting accuracy.
Capabilities
Setting Voltage range 0.1 to 250.0 V, 100 mV resolution, Accuracy: ±0.1 % of setting ±150 mV
(Accuracy)
251 to 1000 V, 1 V resolution, Accuracy: ±0.1 % of setting ±400 mV
0.1 to 250.0 V: 5/ 10/ 50 mA, 251 to 1000 V: 5/ 10 mA
Current Limiter
Measurement Time Setting Delay: 0 to 9,999 msec, Sampling time: 2 to 300 msec
Comparator measurement, deviation measurement, percentage measureFunctions
ment, surface resistivity, volume resistivity, voltage monitor, contact check
10 types of discharge, charge, measure and measurement sequence disProgram Function
charge patterns can be programmed.
Up to 1,000 measurement values can be stored
Data Storage
LCD (8 lines of 30 characters), with backlight, High voltage warning indicator
Display
GP-IB, RS-232C or Handler Interface
Interfaces
100 V AC ±10% (standard), (115, 220 or 240 V AC factory option), 50/60 Hz, 55 VA
Power supply
Dimensions and mass 332 mm (13.07 in)W × 89 mm (3.50 in)H × 450 mm (17.72 in)D, 6.7 kg (236.3 oz)
Power cord ×1, Instruction manual ×1
Accessories
MEASURING LEAD
(BLACK) 0GE00001
MEASURING LEAD
(RED) 0GE00002
MEASURING LEAD
(RED) 0GA00007
MEASURING LEAD
(BLACK) 0GA00008
1 m (3.28 ft) length
1 m (3.28 ft) length
1 m (3.28 ft) length
1 m (3.28 ft) length
Other
Measurement Lead
Interlock Connection
Cable DSM8104F
Note: Other measurement
electrodes are available
4-Channel Measurement System
DIGITAL SUPER MEGOHMMETER DSM-8542
POWER SUPPLY UNIT PSU-8541
■ DSM-8542 Basic specifications (Accuracy guaranteed for 1 year)
Number of channels 4 ch
Same as DSM-8104 specifications
(Except with 4 measurement channels. Not available for voltage generator, Mass:
Other
7.0 kg (246.9 oz))
DSM-8542
DSM-8542
DSM-8542
Not CE Marked
PSU-8541
■ PSU-8541 Basic specifications
Voltage generator [HIGH]: 1 circuit, [LOW]: 1 circuit
Current limiter circuits [Measurement system]: 4 circuits (common ground 2
Configuration
circuits × 2 pairs)
Current limiter circuits [Charge System]: 20 circuits (common ground 5 circuits
× 4 pairs)
Voltage Generator
HIGH (Accuracy)
Voltage Generator
LOW (Accuracy)
Current limiter
Control
Rear panel
•Measures insulation resistance of capacitive/highly insulated materials at
high speed with high accuracy
•The DSM-8542 is 4-channel version of the DSM-8104 (Not available for
testing voltage output), measurement or other functions are sames as the
DSM-8104 specification
•Simultaneous 4-channel measurement capabilities available when combined
with the PSU-8541
0.1 V to 250.0 V (±0.1 % of setting ±150 mV), Max. 600 mA
251 V to 1,000 V (±0.1 % of setting ±400 mV), Max. 120 mA
0.1 V to 10.0 V (±0.1 % of setting ±150 mV), Max. 600 mA
0.1 V to 250.0 V: 5/10/25/50 mA, 251 V to 1,000 V: 5 mA
Controlled by the DSM-8542
Voltage Setting, Current Limit for Measurement (common for all channels),
Current Limit for Charging (common for all channels), Voltage Output On/
Control Method
Off, Voltage Generator Filter On/Off
100 V AC ±10 %, 50/60 Hz, 350 VA
Power supply
Dimensions and mass 332 mm (13.07 in)W × 178 mm (7.01 in)H × 450 mm (17.72 in)D, 28 kg (987.7 oz)
Power cord ×1,Instruction manual ×1
Accessories
Note: RS-232C connection cable: The optional RS-232C Cable 9637 cannot be used with this
product. Use a cross cable for connections as described in the instruction manual.
Other options refer to the detailed catalog
MEASURING LEAD
(BLACK) 0GE00001
MEASURING LEAD
(RED) 0GE00002
MEASURING LEAD
(RED) 0GA00007
MEASURING LEAD
(BLACK) 0GA00008
1 m (3.28 ft) length
1 m (3.28 ft) length
1 m (3.28 ft) length
1 m (3.28 ft) length
Other
Measurement Lead
46
Interlock Connection
Cable DSM8104F
Note: Other measurement
electrodes, or control
cables are available
Super Meg-ohm Testers
Super Megohm Measurement in Any Field
SUPER MEGOHMMETER SM-8213/8215
ULTRA MEGOHMMETER SM-8220
Not CE Marked
SM-8220
Note: RS-232C connection cable: The optional RS-232C Cable 9637 cannot be used with this
product. Use a commercially available straight 9-pin/9-pin cable.
*The 0GE00001, 0GE00002 are bundled
MEASURING LEAD
(RED) 0GE00002
MEASURING LEAD
(RED) 0GA00007
MEASURING LEAD
(BLACK) 0GA00008
1 m (3.28 ft) length
1 m (3.28 ft) length
1 m (3.28 ft) length
1 m (3.28 ft) length
*To connect the Super Meg-ohm meter to a printer, a commercially available RS-232C cross 9-pin (female) to 9-pin (male) cable is required
DC Output (ResistivityProportional Output)
RP-8000
Printer options
MEASURING LEAD
(BLACK) 0GE00001
Factory option
Measurement Lead
DC Output (1/R) RI-8000
Super Meg-ohm
Testers
•Ultra megohm measurement
•Digital/analog display on LCD
•Compatible for measurement of several sample types with electrodes &
other devices
■ Basic specifications (Accuracy guaranteed for 1 year)
SM-8213
SM-8215
SM-8220
2.5 ×104 - 1 ×1011 Ω
5V
5 ×104 - 2 ×1011 Ω
5 ×104 - 2 ×1014 Ω
10 V
7.5 ×104 - 3 ×1011 Ω
15 V
1.25 ×105 - 5 ×1011 Ω
1.25 ×105 - 5 ×1014 Ω
Measuring 25 V
2.5 ×105 - 1 ×1012 Ω
2.5 ×105 - 1 ×1012 Ω
2.5 ×105 - 1 ×1015 Ω
resistance 50 V
range
5 ×105 - 2 ×1012 Ω
5 ×105 - 2 ×1012 Ω
5 ×105 - 2 ×1015 Ω
100 V
1.25 ×106 - 5 ×1012 Ω 1.25 ×106 - 5 ×1015 Ω
250 V
2.5 ×106 - 1 ×1013 Ω
2.5 ×106 - 1 ×1016 Ω
500 V
5 ×106 - 2 ×1013 Ω
5 ×106 - 2 ×1016 Ω
1000 V
±10 % (within 10 times range of min. value on each range at 20°C ), but ± 20 %
Measuring accuracy
at 10^8 range of the SM-8220
Max. 50 mA
Max. 2 mA
Output current
LCD (digital & analog display)
Display
Timer (1 to 999s), Comparator, Remote start, HV-EN (interlock)
Standard function
RS-232C, Comparator output (open-collector)
Interfaces
Selectable 100, 120, 220 or 240 V AC ±10%, 50/60 Hz, 25 VA
Power supply
Dimensions and mass 284 mm (11.18 in)W × 139 mm (5.47 in)H × 215 mm (8.46 in)D, 4.3 kg (151.7 oz)
Instruction manual ×1, Power cord ×1, Measuring lead (black) 0GE00001 ×1,
Accessories
Measuring lead (red) 0GE00002 ×1, Short plug (internal) ×1
PRINTER 9442
AC ADAPTER RECORDING PAPER
For printing numerical 9443-02
1196
values 112 mm (4.41 in) For the Printer 9442, For the Printer 9442, 112 mm (4.41
paper width
EU type
in) × 25 m (82.03 ft), 10 rolls/set
Other measurement electrodes are available
47
Super Meg-ohm Testers
Options for Super megohm meters (for surface resistance or volume resistance measurement)
SURFACE/VOLUME RESISTANCE MEASUREMENT ELECTRODE SM9001
Not CE Marked
• Electrodes compliant with the JIS C 2170
and IEC 61340-2-3 standards
• Measurement voltage up to 1,000 V, and
measurement resistance up to 1013 Ω
• Surface and volume resistance of sheets
and films can be measured just as they
are without the need to cut samples
• Measure the surface resistance of antistatic flooring and molded products
Super Meg-ohm
Testers
Dimensions: φ 100mm (3.94in) × 223mm
(8.78in), Mass: 2.5 kg (88.2oz)
Measurement object
Ring electrode
Measurement
Main electrode
object
Counter
Surface Resistance Measurement electrode Volume Resistance Measurement
Ring
Measure the surface resistance Measure the volume resistance of the sample electrode
between the main electrode and ring sandwiched between the main electrode and
electrode of the main body electrode. counter-electrode.
Note: When used in combination with the DSM-8104
or SM-8220 super megohm meter, Measurement
resistance range*: 103 to 1013 Ω (* When using the
SM-8220: 5 × 104 to 1013 Ω)
Electrode for surface resistance SME-8301
Not CE Marked
Main electrode
Surface resistance can be easily measured
by simple pushing the electrode against the
specimen. It measures surface resistance
of anti-static related goods in combination
of mainly Model SM-8213.
Main
electrode
VERIFICATION FIXTURE FOR SURFACE RESISTANCE
MEASUREMENT SM9002
The SM9002 Verification Fixture for Surface Resistance Measurement (option) allows you to check the operation of the electrode to
increase the reliability of measurement results.
Electrode for surface resistance SME-8302
Not CE Marked
An electrode distance: 4mm (0.16in)
Dimensions: φ 40mm (1.57in) × 115mm (4.53in),
Lead length 1m (3.28ft)
Electrode for surface resistance of curved
samples such as resin and rubber processed goods, TV cathode tubes or small
samples. Surface resistance can be measured by pressing the rubber tips at the tip
onto the sample. Measure electrodes up
to 1010Ω at 10mm intervals or greater.
Dimensions: φ 60mm (2.36in) × 50mm (1.97in), Lead length 1m (3.28ft)
Electrode for plates SME-8311
Electrode for plate samples SME-8310
Not CE Marked
Not CE Marked
Sample of 100mm square by up to 8mm
in thickness is measurable. The main
electrode dia. is 50mm and inner & outer
dia. of ring electrode are 70mm & 80mm
respectively. Meas. voltage becomes
"OFF" while the lid is open to ensure
safety. A selector switch allows selection
of voltage or surface resistivity.
Dimensions: 215mm (8.46in) W × 78mm (3.07in)H × 165mm (6.50in)D, Lead length 75cm (2.46ft)
Electrode for liquid samples SME-8330
Not CE Marked
Dimensions: 215mm (8.46in) W × 78mm (3.07in)H × 165mm (6.50in)D, Lead length 75cm (2.46ft)
Weight electrode SME-8320
Not CE Marked
Included: Banana clips ×2
Photo is Combination with Shield
box SME-8350
This is an electrode for plate sample for
use together with SME-8350 shield box.
This electrode enables extremely easy
measurement of surface resistivity and
volume of sample with coarse surface
such as carpets, etc. The main electrode
dia. is 50mm, and the ring electrode
inner-dia. and outer-dia. are 70mm and
80mm respectively.
Shield box SME-8350
Sample of 40~100mm square by up to
8mm in thickness is measurable. The
main electrode dia. is 19.6mm and inner
& outer dia. of ring electrode are 24.1mm
& 28.8mm respectively. Meas. voltage
becomes "OFF" while the lid is open to
ensure safety.
The fundamental specifications are the
same as SME-8310.
Included: Connection cable Red/ Black
each 1, 60cm (1.97ft)
Dimensions: φ 36mm (1.42in) × 140mm
(5.51in)
Electrode for liquid samples which is electrically guarded. Total volume is 25ml. Capacitance between main and counter electrode is
approx. 45pF. Electrode constant is approx.
500cm. Distance between both electrodes is
1mm. Outer dia. is 36mm, height is approx.
140mm. Measure resistance up to 1019Ω (at
1000V) when used together with Model SM8216.
Note: Includes inspection data sheet
Electrode for chip capacitor SME-8360
Not CE Marked
For measuring the resistance of tip capacitors, with adjustable jig from 0mm to
11mm. When connected to the meter by
an interlock cable, measurement voltage
becomes “OFF” while the lid is open to
ensure safety.
Dimensions: 200mm (7.87in) W × 520mm (2.05in)H × 150mm
(5.91in)D, Lead length 85cm (2.79ft)
Not CE Marked
Standard resistor box SR-2
Not CE Marked
This is used as a sample accommodation
box during measurement of a high-insulation resistance samples, or inductive or
capacitive samples to perform electromagnetic shielding.
This is a resistor box for calibration of the
super megohmmeters.
Max. voltage is 1,000VDC and resistor
value covers from 10MΩ to 10,000MΩ in
24 points.
Note: Includes inspection data sheet
Includes rubber sheet
Dimensions: 250mm (9.84in) W × 100mm (3.94in)H × 200mm (7.87in)D, Lead length 80cm (2.62ft)
48
Dimensions: 270mm (10.63in) W × 90mm (3.54in)H × 195mm
(7.68in)D, Lead length 75cm (2.46ft)
DMM
Benchtop 5-1/2 digit DMM with high-speed comparator and high-accuracy
DIGITAL HiTESTER 3237, 3238, 3239
Basic and economical
3237/3237-01
High-accuracy & multi-functional
3238/3238-01
Cannot be used with any
industrial power line of
greater than 250V
-01 model
Economy model offering basic functionality for optimal cost performance
For 4-terminal resistance measurement
3239/3239-01
Multifunctional, high-accuracy model that
adds AC/DC current and frequency measurement functionality to the 3237
Rear panel (-01 specifications, shared by all 3 models)
CAT II 300 V
CAT I 500 V
•High-speed 3.3 msec comparator for production line use
•Comparator function with open-collector output, beep sound, or LED
display
•Built in RS-232C interface and External control I/O, or added GP-IB
interface (-01 model)
3237 (Built-in RS-232C interface)
3237-01 (Built-in RS-232C & GP-IB interface)
3238 (Built-in RS-232C interface)
3238-01 (Built-in RS-232C & GP-IB interface)
DMM
3239
Adds 4-terminal measurement functionality
to Model 3238 for even more accurate resistance measurements
Sampling speed Values in the ( ) show samples/s
Frequency
FAST
MEDIUM
SLOW
50 Hz
3.3 ±1 ms (300)
130 ±5 ms (8)
1040 ±50 ms (1)
60 Hz
3.3 ±1 ms (300)
108 ±5 ms (9)
1080 ±50 ms (1)
* Approximately 55 ms required for self-calibration at 30-minute intervals.
Does not apply at resistances higher than 2MΩ, or LPΩ higher than 200kΩ.
3239 (Built-in RS-232C interface)
3239-01 (Built-in RS-232C & GP-IB interface)
■ Basic specifications (Accuracy guaranteed for 1 year, Basic accuracy is when sampling rate “Slow”)
3237
DC voltage range
Basic accuracy
AC voltage range
Basic accuracy
Resistance (2-terminals)
Basic accuracy
LP resistance (2-terminals)
Basic accuracy
Continuity Test
Open terminal voltage
DC current range
Basic accuracy
AC current range
Basic accuracy
Hz (Frequency)
Basic accuracy
Resistance (4-terminals)
Basic accuracy
LP Resistance (4-terminals)
Basic accuracy
Sampling rate
Display
Functions
Interface
Power supply
Dimensions and mass
Accessories
3238
3239
199.999 m/1999.99 m/19.9999/199.999/1000.00 V
±0.025 % rdg. ±2 dgt. (2 V range)
± 0.01 % rdg. ±2 dgt. (2 V range)
1999.99 m/19.9999/199.999/750.00 V
±0.2 % rdg. ±100 dgt. (45 Hz to 3 kHz)
±0.1 % rdg. ±100 dgt. (45 Hz to 10 kHz)
199.999/1999.99/19.9999 k/199.999 k/1999.99 k/19.9999 M/100.000 MΩ
±0.05 % rdg. ±2 dgt. (2000 to 200 kΩ range)
±0.02 % rdg. ±2 dgt. (2000 to 200 kΩ range)
1999.99/19.9999 k/199.999 k/1999.99 kΩ
±0.05 % rdg. ±6 dgt. (2000 to 200 kΩ range)
±0.02 % rdg. ±6 dgt. (2000 to 200 kΩ range)
A built-in buzzer sounds when the resistance value is less than 50.00 Ω.
6 V (Ω, Diode check), 0.45 V (Continuity check, LPΩ )
N/A
199.999 m/1999.99 mA
±0.1 % rdg. ±6 dgt. (200 mA range)
N/A
199.999 m/1999.99 mA
±0.3 % rdg. ±100 dgt. (200 mA range, 45 Hz to 3 kHz)
N/A
99.9999/999.999/9.99999 k/99.9999 k/300.000 kHz (Min. measurement 10 Hz)
±0.015 % rdg. ±2 dgt. (Input level : 0.2 V to 700 V, 4 ranges)
N/A
N/A
199.999/1999.99 /19.9999 k/199.999 k/1999.99 kΩ
±0.02 % rdg. ±2 dgt. (2000 to 200 kΩ range)
N/A
N/A
1999.99 /19.9999 k/199.999 k/1999.99 kΩ
±0.02 % rdg. ±6 dgt. (2000 to 200 kΩ range)
300 times/s (Fast), 8 to 9 times/s (Medium), 1 time/s (Slow)
Digital LED, max. 199999 dgt.
Comparator, Save/Load of settings (Up to 30 types of setting conditions), Printer output, Current measurement with clamp-on probes and scaling, External control I/O
External input/output (input: C-MOS level (high: 3.8 to 5 V; low: 0 (short) to 1.2 V); output: open collector (max. 35 V DC/50 mA); RS-232C (standard) and GP-IB (option, -01 specifications))
100/ 120/ 220/ 240 V AC (specify when ordering), 50/60 Hz
215 mm (8.46 in)W × 80 mm (3.15 in)H × 265 mm (10.43 in)D, 2.6 kg (91.7 oz)
Test lead L9170-10 ×1, Instruction manual ×1, Power cord ×1, Spare fuse each 1
*L9170-10 is a bundled accessory. *Requires the 9704 to connect a Clamp-on probe
70 cm (2.30 ft) length
1000 A AC
CLAMP ON PROBE 9010-50
500 A AC
CONVERSION ADAPTER 9704
Receiving end: Female BNC; Output end: Male banana-plug *Not
compatible with older generation Memory Hicorders with banana
input terminals
AC ADAPTER 9443-02 CONNECTION CABLE 9444
For printing numerical values For the Printer 9442, EU type For the Printer 9442, 9 pin - 9 pin, 1.5
m (4.92 ft) length
112 mm (4.41 in) paper width
RECORDING PAPER 1196
For the Printer 9442, 112 mm (4.41
in) × 25 m (82.03 ft), 10 rolls/set
PC communication
Printer options
PRINTER 9442
CLAMP ON PROBE 9132-50
RS-232C CABLE 9637 RS-232C CABLE 9638
4-Terminal measurement probes
About probe length
φ 0.8mm
PIN TYPE LEAD 9461
A:240 mm (9.45 in), B:132
mm (5.20 in), L:804 mm
(2.64 ft)
Current side
Voltage side
0.2mm / φ 0.2
PIN TYPE LEAD 9455
A:260 mm (10.24 in), B:136 mm (5.35
in), L:890 mm (2.92 ft), Not CE marked
CLIP TYPE LEAD 9287-10
ZERO ADJUSTMENT FOUR TERMINAL LEAD 9453 CLIP TYPE LEAD 9452 A:130 mm (5.12 in), B:83 mm
A:220
mm
(8.66
in),
B:197
A:280
mm
(11.02
in),
B:118
mm
BOARD 9454
(3.27 in), L:1100 mm (3.61 ft),
For the L2100, 9465-10,
9465, 9461
GP-IB CONNECTOR
For the PC, 9pin - 9pin, cross, For the PC, 9pin - 25pin, cross, CABLE 9151-02
1.8m (5.91 ft) length
1.8m (5.91 ft) length
2 m (6.56 ft) length
Note: The 9455 is a precision instrument.
Exercise appropriate care when handling it.
6
14mm
Input Lead
TEST LEAD
L9170-10
(4.65 in), L:1360 mm (4.46 ft),
60V DC
mm (7.76 in), L:1360 mm
(4.46 ft)
70V DCL:1100 mm (3.61 ft),
70V DC
A: From junction to probe
B: Probe part
L: Whole length
49
DMM/Signal Generator
Introducing a new digital, multi-module DMM (Digital-Multi-Module) station
DMM Station MR8990+MR8741/8740
marked
DMM
Signal Ganerator
8 modules of the DVM unit MR8990 install into the
Memory HiCorder MR8741 to create a DMM station
DIGITAL VOLTMETER UNIT MR8990
•Introducing the DVM Unit MR8990, which can measure DC voltages on 2
channels (for use with the Memory HiCorder MR8741/8740 only)
•High-precision measurement for applications such as investigating minute
voltage fluctuations in sensor output
•The MR8741 (MR8740) can save data from 16 (54) Digital-Multi-Meters at
once. (DCV measurement only)
•Unlike standard multichannel scan-type loggers, these instruments can perform simultaneous sampling
•High accuracy of ±0.01 % and super-high 1.2 million-count resolution
•High-speed sampling at 500 samples/s
•Isolated input (channel-to-channel and channel-to-chassis: max. rated voltag to
earth of 300 V AC/DC)
Instrument requires input units and other dedicated options. Input cords not included.
The MR8990 cannot operate alone.
Inserted next to instrument; mix and match. For other options, please see the product catalog.
Options
DIGITAL VOLTMETER UNIT MR8990
2 ch, high-precision DC V input, 0.1 μV
resolution, high-speed sampling 500 times/s
ANALOG UNIT 8966
2 ch, voltage input, DC to 5 MHz band
TEMP UNIT 8967
2 ch, thermocouple temperature input
HIGH RESOLUTION UNIT 8968
2 ch, voltage input, DC to 100 kHz band
STRAIN UNIT 8969
2 ch, strain gauge type converter amp
*Includes Conversion Cable 9769
FREQ UNIT 8970
2 ch, for measurement of frequency, rpm,
pulse, etc.
DC/RMS UNIT 8972
2 ch, voltage/DC to 400 kHz, RMS rectifier,
DC and 30 to 100 kHz band
LOGIC UNIT 8973
4 terminals, 16 ch
CURRENT UNIT 8971
2 ch, for measuring current using dedicated
current sensors, use up to 4 with MR8740;
not compatible with MR8741
■ DVM Unit MR8990 basic specifications (Accuracy guaranteed for 1 year)
Install into Memory HiCorder MR8740/8741 for use; 2 channels of DC
Measurement
voltage measurement
functions
100 mV range (5 mV/div.): -120.0000 mV to 120.0000mV, 0.1 μV resolution
Measurement ranges to
(20 div. f.s.)
500 V range (50 V/div.): -500.000 V to 500.000 V, 1 mV resolution, 5 ranges
Measurement accuracy Basic accuracy: ±0.01% rdg. ±0.0025% f.s.
Max. allowable input 500 V DC (upper limit voltage that can be applied between input terminals without damage)
Max. rated voltage 300 V AC/DC (input and instrument are isolated; upper limit voltage that can be
applied between input channels or between input channels and chassis without damage)
to earth
Max. sampling rate 2 ms (500 samples/s)
■ Main Unit MR8740/8741 basic specifications (Accuracy guaranteed for 1 year)
MR8740
MR8741
Block I: 16 analog units]
From 32 analog + 8 standard logic
[Block I: 13 analog units + 3 logic units]
26 analog + 56 logic (8 standard logic + 48
logic unit)
[8 analog units]
From 16 analog + 16 standard logic
[Block II: 11 analog units]
[5 analog units + 3 logic units]
From 22 analog + 8 standard logic
Number of
10 analog + 64 logic (16 standard
[Block II: 8 analog units + 3 logic units]
channels
16 analog + 56 logic (8 standard logic + 48 logic + 48 logic unit)
logic unit)
*Instrument consists of two blocks, Block I and Block II
*Block I and Block II start measurement simultaneously
by means of trigger synchronization (internal setting)
*Analog unit channels are isolated from each other and from the recorder. Logic unit channels
and standard logic terminal channels share a common GND with the recorder.
Memory capacity 16 MW/ch (fixed), total of 864 MW installed 16 MW/ch (fixed), total of 256 MW installed
External storage USB memory (2.0)
None (1 digital DVI terminal per block, 800 None (1 digital DVI terminal, 800 ×
Display
× 600 dots)
600 dots)
External
interfaces
Power supply
Dimensions and
mass
Accessories
[LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server)
[USB] USB 2.0 Series A receptacle × 2 (mouse operation)
100 to 240 V AC, 50/60 Hz (250 VA max.)
100 to 240 V AC, 50/60 Hz (120 VA max.)
426 mm (16.77 in)W × 177 mm (6.97 in)H × 505 350 mm (13.78 in)W × 160 mm (6.30 in)
mm (19.88 in)D, 10.8 kg (3809.5 oz) (main unit H × 320 mm (12.60 in)D, 5.4 kg (190.5
only)
oz) (main unit only)
Instruction manual ×1, Application disk (Wave viewer Wv, Communication commands table) ×1, Power cord ×1
Generate and Measure Signals Simultaneously
DC SIGNAL SOURCE SS7012
Communication only
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
[Generation functions]
Bipolar sink and source
Circuit method
2.5 V: 0 to ±2.5000 V (±0.03 % of setting ±300 μV, 100 μV resolution)
Constant Voltage
25 V: 0 to ±25.000 V (±0.03 % of setting ±3 mV, 1 mV resolution)
Constant Current 25 mA: 0 to ±25.000 mA (±0.03 % of setting ±3 μA, 1 μA resolution)
K: at TC: 0 ˚C, -174.0 to 1372.0 ˚C (±0.05 % of setting ±0.5 ˚C, 0.1 ˚C resoThermoelectric
lution), Other types: E, J, T, R, S, B, N selectable
power generation
Thermoelectric
power generation
Standard resistance (Rs)
Automatic generation
•Improve stability and reduce calibration costs compared with the previous
HIOKI model
•For instrumentation systems (4 - 20 mA) and loop testing
•Check temperature control equipment and electric distribution
•8 types of thermocouples to test thermoelectric power generation
•Ideal for electrical device testing and routine maintenance of production
equipment such as calibrators
•Use the max. 25 mA DC sink as an electric load
K: at TC: RJ, -174.0 to 1372.0 ˚C (±0.05 % of setting ±1.0 ˚C, 0.1 ˚C resolution), Other types: E, J, T, R, S, B, N selectable
100 Ω (±0.2 Ω)
Number of memory steps: 20, Interval time: 1 to 99 sec (at CV, CC, TC mode)
[Measurement functions]
2.5 V: 0 to ±2.8000 V (±0.03 % rdg. ±300 μV, 100 μV resolution, 1 MΩ input resistance)
Voltage
25 V: 0 to ±28.000 V (±0.03 % rdg. ±3 mV, 1 mV resolution, 1 MΩ input resistance)
25 mA: 0 to ±28.000 mA (±0.03 % rdg. ±3 μA, 1 μA resolution, 25 Ω input resistance)
Current
-25.0 to ±80.0 ˚C (±0.5 ˚C at 23 ±5 ˚C, 0.1 ˚C resolution, use with the RJ sensor 9184)
Temperature
Approx. 1.67 times/sec
Sampling rate
Additional functions Zero adjustment, Overflow display, USB communication, Monitor
AC adapter 9445-02/03 (100 to 240 V AC 50/60 Hz, 9 VA),
Ni-MH battery HR6 × 4, 6 VA, (fully charged 2500 mAh Ni-MH batteries: 170
Power supply
minutes continuous use), or LR6 (AA) alkaline battery × 4, 6 VA
104 mm (4.09 in)W × 180 mm (7.09 in)H × 58 mm (2.28 in)D, 660 g (23.3 oz)
Dimensions and
(including LR6 × 4 batteries)
mass
Input cord 9168 ×1, Test lead L9170-10 ×1, Fuse ×1, LR6 (AA) alkaline batAccessories
tery ×4, Instruction manual ×1
Use of the AC Adapter and /or rechargeable batteries and dedicated charger is
recommended
*Bundled accessories
70 cm (2.30 ft) length
TEST LEAD
L9170-10
70 cm (2.30 ft) length
50
Options
Cables
INPUT CORD 9168
Commercially available rechargeable batteries
(AA Ni-MH batteries ×4) may also be used to
power the SS7012. Using locally purchased
rechargeable batteries and dedicated battery
chargers is recommended; however, HIOKI
will not be able to guarantee operating time as COMMUNICATION
different rechargeable batteries exhibit different PACKAGE SS9000
power specifications per charge. The SS7012 USB cable, USB driver
cannot be used to recharge batteries.
software included
CARRYING CASE
9782
AC ADAPTER
9445-02/03
Includes compartment
for options, Hard type
100 to 240 V AC
CARRYING CASE 9380 TEMPERATURE
For the SS7012, 7011 for
PROBE 9184
storing the main body only, For reference contact
soft type
compensation
Safety Testing
Leak current measurement, an essential part of electrical safety (Medical-use Electrical Devices/For Standard- and Regulation compliance)
LEAK CURRENT HiTESTER ST5540
■ Basic Specifications (Accuracy guaranteed for 1 year)
Measurement of voltage drop across body simulated resistance points, Calculation and display of
Measurement
current values, True rms measurement, Measurement unit floats relative to instrument ground.
methods
Measurement modes Leak current measurement, voltage measurement, safety conductor current measurement
marked
Standard
compliance
Note: Always use an isolation transformer when measuring leak current for medical-use
electrical devices. The ST5540 does not include an isolation transformer. When measuring
medical-use electrical devices, use a step-up isolation transformer or similar component
operating at 110% of the rated supply voltage as the power supply for the device under test.
*The L2200 (for ST5540, Red ×2, Black ×1) ×1 set and the 9195 are bundled accessories
Test probes
TEST LEAD L2200
Red/ Black ×1, 70cm (2.30ft) length,
detachable large alligator clips or needle tips
are bundled, CAT IV 600V, CAT III 1000V
ENCLOSURE
PROBE 9195
For the ST5540series,
3156/3155
Leak current
measurement
Measurement current
Measurement
ranges
Measurement
accuracy
(current measurement)
Interfaces
Functionality
DC, AC (true rms, 0.1 Hz to 1 MHz), AC+DC (true rms, 0.1 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
DC / AC / AC+DC mode:50 μA/500 μA/5 mA/50 mA
AC peak mode:500 μA/1 mA/10 mA/75 mA
DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
External I/O, medical device relay output, USB 1.1 (communications), RS-232C
110% voltage application, automatic test, data storage for 100 target devices,
clock, data backup, printed output (optional), etc.
100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
Safety Testing
•IEC 60601-1: (2005) 3rd Edition, JIS T0601-1:2012 compliant
•The ST5540 complies with JIS, IEC, and UL standards governing medicaland general-use electrical devices.
•Uninterrupted polarity switching function dramatically reduces cycle time.
•Support for rated currents up to 20 A gives the instrument more than
adequate capability for testing products designed to comply with new standards.
•Touch panel features simple, interactive operation.
•Communications functionality and external I/O support allow automatic
testing on production lines.
Medical electrical equipment: IEC 60601-1 (1988) + A2:1995, (2005, 3rd Edition), JIS
T0601-1:1999, 2012
Electrical Appliances and Materials Safety Act
Measurement of touch current and protective conductor current: IEC 60990 (1999)
Electrical equipment for measurement, control, and laboratory use: IEC 61010-1 (2001)
Information technology equipment: IEC 60950-1 (2005)
Household and similar appliances: IEC 60335-1 (2001) + A1:2004 + A2:2006
Audio, video and similar electronic apparatus: IEC 60065 (2001) + A1:2005
Personnel Protection Systems for EV: UL-2231-1 (2002), UL-2231-2 (2002)
UL: UL-1492 (1996)
Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1 (2001)
Ground leak current, 3 types of contact current, 7 types of patient leak current,
patient measurement current, 4 types of total patient leak current, free current
measurement, 3 types of enclosure leak current
Power supply
Target device power
100 to 240 V AC, 50/60 Hz Rated current input from terminal block: 20 A
supply input
Target device power
Output from terminal block: 20 A Output from outlet: 15 A
supply output
Dimensions and mass 320 mm (12.60 in)W × 110 mm (4.33 in)H × 253 mm (9.96 in)D, 4.5 kg (158.7 oz)
Test lead L2200 (for ST5540, Red ×2, Black ×1) ×1 set, Enclosure probe 9195 ×1,
Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1,
Accessories
Users guide ×1, CD-ROM ×1
Leak current measurement, an essential part of electrical safety (For Standard- and Regulation compliance)
LEAK CURRENT HiTESTER ST5541
■ Basic Specifications (Accuracy guaranteed for 1 year)
Measurement of voltage drop across body simulated resistance points,
Calculation and display of current values, True rms measurement,
Measurement unit floats relative to instrument ground.
Measurement modes Leak current measurement, voltage measurement, safety conductor current measurement
Measurement
methods
marked
Standard
compliance
•LEAK CURRENT HiTESTER ST5541: A low-cost solution that complies with
standards governing general-use electrical devices
•Uninterrupted polarity switching function dramatically reduces cycle time.
•Support for rated currents up to 20 A gives the instrument more than
adequate capability for testing products designed to comply with new standards.
•Touch panel features simple, interactive operation.
•Communications functionality and external I/O support allow automatic
testing on production lines.
Note: For applications involving leak current measurement of medical-use electrical devices,
use the ST5540.
*The L2200 and the 9195 are bundled with the ST5541
Test probes
TEST LEAD L2200
Red/ Black ×1, 70cm (2.30ft) length,
detachable large alligator clips or needle tips
are bundled, CAT IV 600V, CAT III 1000V
Leak current
measurement
Measurement current
Measurement
ranges
Measurement
accuracy
(current measurement)
Interfaces
Functionality
Electrical Appliances and Materials Safety Act
Measurement of touch current and protective conductor current: IEC 60990 (1999)
Electrical equipment for measurement, control, and laboratory use: IEC 61010-1 (2001)
Information technology equipment: IEC 60950-1 (2005)
Household and similar appliances: IEC 60335-1 (2001) + A1:2004 + A2:2006
Audio, video and similar electronic apparatus: IEC 60065 (2001) + A1:2005
Personnel Protection Systems for EV: UL-2231-1 (2002), UL-2231-2 (2002)
UL: UL-1492 (1996)
Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1 (2001)
Ground leak current, 3 types of contact current, free current measurement,
3 types of enclosure leak current
DC, AC (true rms, 15 Hz to 1 MHz), AC+DC (true rms, 15 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
DC / AC / AC+DC mode:50 μA/500 μA/5 mA/50 mA
AC peak mode:500 μA/1 mA/10 mA/75 mA
DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
External I/O, USB 1.1 (communications), RS-232C
Automatic test, data storage for 100 target devices, clock, data backup,
printed output (optional), etc.
100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
Power supply
Target device power
100 to 240 V AC, 50/60 Hz Rated current input from terminal block: 20 A
supply input
Target device power
Output from terminal block: 20 A Output from outlet: 15 A
supply output
Dimensions and mass 320 mm (12.60 in)W × 110 mm (4.33 in)H × 253 mm (9.96 in)D, 4.5 kg (158.7 oz)
Test lead L2200 (Red ×1, Black ×1) ×1 set, Enclosure probe 9195 ×1, Power
cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, Users
Accessories
guide ×1, CD-ROM ×1
ENCLOSURE
PROBE 9195
For the ST5540series,
3156/3155
ST5540, ST5541 shared options
values 112 mm (4.41 in) For the Printer 9442,
paper width
EU type
CONNECTION
CABLE 9444
RECORDING
PAPER 1196
For the Printer 9442, For the Printer 9442,
9 pin - 9 pin, 1.5 m
112 mm (4.41 in) × 25 m
(4.92 ft) length
(82.03 ft), 10 rolls/set
PC communication
Printer options
AC ADAPTER
For printing numerical 9443-02
PRINTER 9442
RS-232C CABLE 9637
RS-232C CABLE 9638
For the PC, 9pin - 9pin,
For the PC, 9pin - 25pin,
cross, 1.8m (5.91 ft) length cross, 1.8m (5.91 ft) length
51
Safety Testing
■ ST5540, ST5541 List of functions
Network
Major
functions
Item
Network A
(Electrical Appliances and Materials Safety Act)
Network B (Medical-use electrical devices)
Network C (IEC 60990)
Network D (UL)
Network E (General-purpose 1)
Network F (General-purpose 2)
Network G (IEC 61010-1)
Power on polarity switching function
Rated current 20 A
Function for checking for blown fuses
Frequency band switching
110% voltage output terminal (T3 terminal)
S10, S12, S13, E terminal
■ ST5540, ST5541 List of functions
ST5540
ST5541
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
-
Testing leakage
current mode
Item
Earth leakage current
Touch current
Patient auxiliary current
Patient leakage current
Total patient leakage current
Free current
Enclosure - Earth leakage current
Enclosure - Enclosure leakage current
Enclosure - Line leakage current
Patient leakage current I
Patient leakage current II
Patient leakage current III
ST5540
4
4
4
4
4
4
4
4
4
4
4
4
ST5541
4
4
4
4
4
4
-
Safety Testing
For multipoint, high-voltage automatic testing and automation of insulation and dielectric strength testing
HIGH VOLTAGE SCANNER 3930
■ Basic Specifications
Multi-mode: Scanning of user-selected points for high 4 ch / low 4 ch
Single mode: Common scan of high 8 ch - common
Rated voltage used 5 kV AC / 5 kV DC
Operation indica- Lamps light up when power is supplied and when a specified channel is
operating
tions
Operation modes
marked
[Relay area]
Max. open and
closed voltage
Max. open and
closed current
5000 V DC, 5000 V AC
1.0 A (open and closed capacity: 50 W)
Contact point indirect
500 mΩ or less, with 1 mA AC
contact resistance
Rear
•Output of the input high voltage from a user-selected channel
•8 ch per unit (single mode), with up to 32 ch (4 connected units)
•Isolated high-voltage I/O, control signal lines, and power supply
•Control using the 3153 program function or with a standard sequencer
Contact point max.
capacity
Time
Power supply
Dimensions and mass
Accessories
50 W
Operation time: 6 ms or less, Recovery time: 6 ms or less
VSCV 24 V DC, ±10% (applied using the control signal input connector), 12 VA max.
316 mm (12.44 in)W × 100 mm (3.94 in)H × 350 mm (13.78 in)D, 4.2 kg (148.1 oz)
Control input connector connection cable ×1, H.V. Test lead 9615-01 (red)
×8, H.V. Test lead (black) ×1, Grounding cable ×1, Instruction manual ×1
*The 9615-01 is bundled
Options
H.V. TEST LEAD 9615-01
Red, high voltage side, 1.5 m
(4.92 ft) length
Control insulation, dielectric strength, protective continuity, and leak current testing from a PC
SAFETY TEST DATA MANAGEMENT SOFTWARE 9267
■ Basic Specifications
Compatible models
Supplied media
Supported
operating systems
ST5540/ST5541, 3153, 3154, 3156, 3157, 3158, 3159, 3174, 3332, 3333, 3334,
and PLCs from various manufacturers (for connection switching)
CD-R ×1
Windows 7 (32-/64-bit), Vista (32-bit), XP/2000/NT 4.0/Me/98/95
Test types
Insulation and dielectric strength, protective continuity, leak current,
energization
Record-keeping
data
Interface
Recording of test results (measured values) as a text file (CSV format)
RS-232C
This dedicated application allows you to control and take measurements through
insulation testing, dielectric strength testing, protective continuity testing, leak current
testing, and energization testing and to record test results as a text file.
•Control the ST5540/5541 as well as the 3153/3154/3156/3157, 3174,
and other instruments from a computer
•Perform automatic insulation and dielectric strength testing of up to
32 points with the High Voltage Scanner 3930
•Easily create and save insulation, dielectric strength, and continuity
test records with a computer as required by the Electrical Appliance
and Material Safety Act (Japan)
52
Safety Testing
Contact check and full remote control
AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER 3174
■ Basic Specifications (Accuracy guaranteed for 1 year)
marked
•Continuous testing of insulation (500/1000 V) and withstand voltage (100 VA
transformer capacity)
•Full remote operation when used in combination with the Safety Test Data
Management Software 9267
•Save up to 8 test settings each for the withstanding and insulation testing
modes
•Precise test voltage without power voltage dependency is generated using
the PWM method
To perform contact checks, please purchase another High Voltage Test Lead 9615 set
separately
*The 9615 is bundled
*The 9637, 9638 are not CE marked when combined with the 3174
REMOTE CONTROL
BOX (SINGLE) 9613
REMOTE CONTROL
BOX (DUAL) 9614
Other
Input/Output cord
H.V.TES LEAD 9615
Safety Testing
[Withstanding test section]
0.2 V AC to 5.00 kV AC
Testing voltage
Digital setting, Setting resolution: 0.01 kV
Voltage setting
Waveform/Frequency Sine wave (Distortion ratio 5 % or less at no load), 50/60 Hz selectable
Current measurement 0.01 mA to 20.0 mA, True RMS rectified (digital display)
Measurement range 10 mA (0.01 mA resolution), 20 mA (0.1 mA resolution)
Accuracy: ±1.5 % rdg. (1000 V or more), ±15 V (less than 1000 V), True RMS rectified
Voltage meter
Judgment function Window comparator method (Digital setting)
[Insulation test section]
500 V DC, 1000 V DC
Testing voltage
Unloaded voltage 1 to 1.2 times rated voltage
Rated testing current 1 to 1.2 mA, Shorted current: 4 to 5 mA (at 500 V), 2 to 3 mA (at 1000 V)
0.5 MΩ to 999 MΩ (at 500 V), and 1 MΩ to 999 MΩ (at 1000 V): ±4 % rdg.,
Measurement
1000 MΩ to 2000 MΩ: ±8 % rdg.
range, Accuracy
Judgment function Window comparator method (Digital setting)
[Timer section] *Test times may differ from set timer times depending on the load.
0.3 to 999 s
Setting range
Testing voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s
Ramp, Delay
[General section]
Saving 8 testing conditions, hold, buzzer, contact check
Functions
Output voltage, detected current, insulation resistance, Refresh rate: 4 times/s
Monitor function
100 to 240 V AC, (50/60 Hz), 200 VA max.
Power supply
Dimensions and mass 320 mm (12.60 in)W × 155 mm (6.10 in)H × 395 mm (15.55 in)D, 15 kg (529.1 oz)
H.V. Test lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1,
Accessories
Instruction manual ×1, Disconnection prevention plate ×1
RS-232C CABLE 9637 RS-232C CABLE 9638
For the PC, 9pin - 9pin,
Red, Black each 1, 1.5 m For Start/Stop control,
For Start/Stop control,
(4.92 ft) length
1.5m (4.92 ft) cord length 1.5m (4.92 ft) cord length cross, 1.8m (5.91 ft) length
For the PC, 9pin - 25pin, cross,
1.8m (5.91 ft) length
SAFETY TEST DATA
MANAGEMENT SOFTWARE
9267
For PC control application software
Programable testing, full remote control, Automatic Insulation Withstanding Tester
AUTOMATIC INSULATION / WITHSTANDING HiTESTER 3153
■ Basic Specifications (Accuracy guaranteed for 1 year)
marked
•Programmable insulation (50 to 1,200 V DC) and dielectric strength (AC/DC)
testing
•Program up to 32 files of test types, test points (50 steps), and measurement
settings
•Optional scanner for multipoint automatic testing
•Uses the PWM method to generate accurate test voltages that do not
depend on the supply voltage
•Ramp timer function for increasing or decreasing the applied voltage during
dielectric strength testing at user-specified times
*The 9615 is bundled
*The 9637, 9638 are not CE marked when combined with the 3153
REMOTE CONTROL
BOX (SINGLE) 9613
REMOTE CONTROL
BOX (DUAL) 9614
Other
Input/Output cord
H.V.TES LEAD 9615
[Withstanding test section]
Testing voltage AC/DC 0.2 kV to 5.00 kV AC, 500 VA (max. 30 minutes), 0.2 kV to 5.00 kV DC, 50 VA (continuance)
Digital setting (0.01 kV setting resolution)
Voltage setting
Waveform/Frequency Sine wave (5% or less distortion, unloaded), 50/60 Hz selectable
Current measurement 0.01 mA to 100.0 mA, Average rectified display (Digital)
Measurement range 10 mA (0.01 mA resolution), 100 mA (0.1 mA resolution)
Digital: accuracy ±1.5 % f.s. (f.s.=5.00 kV) (Average rectified display)
Voltmeter
Window comparison (digital settings)
Decision method
[Insulation test section]
Rated testing voltage 50 to 1,200 V DC (in 1 V steps)
Rated testing current 1 mA, Short-circuit current: 200 mA or less
Measurement range
0.10 to 9999 MΩ, 4 ranges, ± 4 % rdg. (representative values for 0.5 MΩ to 1,000 MΩ)
/ accuracy
Window comparison (digital settings)
Decision method
[Timer section] *Test times may differ from set timer times depending on the load.
0.3 to 999 s
Setting range
Testing voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s
Ramp, Delay
[General section]
Program up to 32 files of 50 step test settings.
Functions
10 sets each of dielectric strength and insulation test settings, hold, buzzer
Monitor functions Output voltage, detected current, measured resistance, Refresh rate: 2 times/s
100 to 120 V, 200 to 240 V AC, (50/60 Hz), 1000 VA max.
Power supply
Dimensions and mass 320 mm (12.60 in)W × 155 mm (6.10 in)H × 480 mm (18.9 in)D, 18 kg (634.9 oz)
H.V. Test lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1,
Accessories
Instruction manual ×1, Spare fuse ×1
RS-232C CABLE 9637 RS-232C CABLE 9638
For the PC, 9pin - 9pin,
Red, Black each 1, 1.5 m For Start/Stop control,
For Start/Stop control,
(4.92 ft) length
1.5m (4.92 ft) cord length 1.5m (4.92 ft) cord length cross, 1.8m (5.91 ft) length
GP-IB CONNECTOR
For the PC, 9pin - 25pin, cross, CABLE 9151-02
1.8m (5.91 ft) length
2 m (6.56 ft) length
HIGH VOLTAGE SCANNER 3930
SAFETY TEST DATA
MANAGEMENT SOFTWARE 9267
Automatic multipoint testing For PC control application
software
of high voltages
53
Safety Testing
Perform insulation resistance and withstand voltage testing in a single series
INSULATION / WITHSTANDING HiTESTER 3159-02
marked
Safety Testing
•Continuous testing of insulation (500/1000 V) and withstand voltage (500 VA
transformer capacity)
•Insulation to withstand series test or witstand to insulation series test at auto
mode, or individual test at manual mode
•Save up to 10 test settings each for the withstanding and insulation testing
modes
•Externa I/O, RS-232C interface, Status output (relay contacts)
Model 3159-02; for 220 V power supplies only
*The 9615 is bundled
[Withstanding test section]
0 to 2.5 kV / 0 to 5.0 kV AC, 2 range configuration 500 VA (30 minutes rated)
Testing voltage
Manual setting
Voltage setting
Waveform/Frequency Same as the power supply waveform, synchronized with the power supply
Current measurement 0.01 mA to 120 mA, True RMS rectified (digital display)
Accuracy: ±1.5 % f.s. (digital), ±5 % f.s. (analog, f.s.=5 kV)
Voltage meter
Current measurement 0.01 mA to 120 mA, (Average value rectified, effective value digital display)
Measurement range 2 mA/8 mA (0.01 mA resolution), 32 mA (0.1 mA resolution), 120 mA (1 mA resolution)
Digital, Accuracy: ±1.5 % rdg. (f.s.=5.00 kV)
Voltage meter
Judgment function Window comparator method (Digital setting)
[Insulation test section]
500 V DC, 1000 V DC, Unloaded voltage: 1 to 1.2 times rated voltage
Testing voltage
Rated testing current 1 to 1.2 mA, Shorted current: 4 to 5 mA (at 500 V), 2 to 3 mA (at 1000 V)
0.5 MΩ to 999 MΩ (at 500 V), and 1 MΩ to 999 MΩ (at 1000 V): ±4 % rdg.,
Measurement
1000 MΩ to 2000 MΩ: ±8 % rdg.
range, Accuracy
Judgment function Window comparator method (Digital setting)
[Timer section]
0.5 to 999 s
Setting range
[General section]
Output voltage, detected current, insulation resistance, Refresh rate: 2 times/s
Monitor function
220 V AC, (50/60 Hz), 800 VA max.
Power supply
320 mm (12.60 in)W × 155 mm (6.10 in)H × 330 mm (12.99 in)D,
Dimensions and
21.5 kg (758.4 oz)
mass
H.V. Test lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1,
Accessories
Instruction manual ×1, Spare fuse ×1
*The 9637, 9638 are not CE marked when combined with the 3159
REMOTE CONTROL
BOX (SINGLE) 9613
REMOTE CONTROL
BOX (DUAL) 9614
Other
Input/Output cord
54
H.V.TES LEAD 9615
■ Basic Specifications (Accuracy guaranteed for 1 year)
RS-232C CABLE 9637 RS-232C CABLE 9638
For the PC, 9pin - 9pin,
Red, Black each 1, 1.5 m For Start/Stop control,
For Start/Stop control,
(4.92 ft) length
1.5m (4.92 ft) cord length 1.5m (4.92 ft) cord length cross, 1.8m (5.91 ft) length
For the PC, 9pin - 25pin, cross,
1.8m (5.91 ft) length
SAFETY TEST DATA
MANAGEMENT SOFTWARE
9267
For PC control application software
Safety Testing
Protective ground tester indispensable for standards certification
AC GROUNDING HiTESTER 3157-01
■ Basic Specifications (Accuracy guaranteed for 1 year)
option
marked
• Easily perform protective continuity testing in compliance with domestic and overseas safety standards and laws
•Protective continuity resistance measurement for medical devices and general electrical devices
•Ground connectivity testing when installing electrical machine tools and distribution panels
•Testing of protective grounding and isopotential grounding work for medical equipment
•Evaluation of contact status using large currents
• Feedback control system that is capable of applying a stable current even with a fluctuating load
• Soft-start function that checks the connection to the device under test before applying the current
AC 4-terminal method resistance measurement
Fluorescent tube (digital display)
3.0 A to 31.0 A AC (0.1 A resolution), into 0.1Ω load
130 VA (at output terminals)
Max. 6 V AC
50 Hz or 60 Hz sine wave (selectable)
0 to 1.800Ω (0.001Ω resolution), Accuracy: ±2% rdg. ±4 dgt. after zero-adjust
0 to 6.00 V AC (single range 0.01 V resolution), Accuracy: (1 % rdg. +5 dgt.)
0 to 35.0 A AC/ 0 to 6 V AC, Refresh rate: 2 times/s
Counts down time after start until preset time, Shows elapsed time after start
0.5 s to 999 s
PASS/FAIL evaluation using preset upper/lower limit, buzzer sound, signal output
Max. 20 settings (with save/load)
EXT I/O, EXT SW, GP-IB or RS-232C (option)
100 to 120 V/200 to 240 V AC (switching, 50/60 Hz)
320 mm (12.60 in)W × 90 mm (3.54 in)H × 263 mm (10.35 in)D, 7 kg (246.9 oz)
Power cord ×1, Instruction Manual ×1, Spare fuse (inlet) ×1, Shorting bar ×2
Safety Testing
Basic functions
Display
Current setting range
Max. output power
Open-terminal voltage
Generator frequency
Resistance measurement
Voltage measurement
Monitor section
Timer display
Timer setting
Comparator
Memory function
Interfaces
Power supply
Dimensions and mass
Accessories
option
*When use the Printer, require the RS-232C Interface 9593-02
Printer options
This instrument is not capable of performing measurement by itself. Please purchase two Current probe
9296 units or one Current probe 9296 and one Current apply probe 9297, depending on your measurement
application.
PRINTER 9442
AC ADAPTER
CONNECTION
CABLE 9446
RECORDING
PAPER 1196
For printing numerical 9443-02
For the Printer 9442, For the Printer 9442,
values 112 mm (4.41 in) For the Printer 9442, 25 pin - 9 pin, 1.5 m
112 mm (4.41 in) × 25 m
paper width
EU type
(4.92 ft) length
(82.03 ft), 10 rolls/set
*The 3157-01’s handshake function cannot be used with the RS-232C Cable 9638
For the 3157-01, built in
type
REMOTE CONTROL
BOX (SINGLE) 9613
REMOTE CONTROL
BOX (DUAL) 9614
For Start/Stop control,
For Start/Stop control,
1.5m (4.92 ft) cord length 1.5m (4.92 ft) cord length
CURRENT PROBE 9296 CURRENT APPLY PROBE 9297 GP-IB CONNECTOR
Alligator clip, 1.45m (4.76 ft) With switch, 1.48m (4.86 ft)
CABLE 9151-02
length
length
2 m (6.56 ft) length
RS-232C INTERFACE
9593-02
Other
Input/Output cord
GP-IB INTERFACE
9518-02
SAFETY TEST DATA
MANAGEMENT SOFTWARE 9267
For PC control application
software
For the 3157-01, built in
type
Insulation resistance testing for system measurement
DIGITAL MΩ HiTESTER 3154
■ Basic Specifications (Accuracy guaranteed for 1 year)
Measurement items Insulation resistance (Applied DC voltage method)
Testing voltage/ mea- 25/ 50 V: 2.000/ 20.00/ 200.0 MΩ,
100/ 250/ 500/ 1000 V: 2.000/ 20.00/ 200.0/ 2000 MΩ (at 500 or 1000 V testing, up
surement ranges
to 4000 MΩ)
(Auto / Manual)
marked
•Six test voltages from 25 V to 1000 V
•Stores 10 setting states
•Comparator and timer functions facilitate easy testing in accordance with
various safety standards
•Start, Stop, or other configuration external control is provided
• Measuring terminals in rear panel is convenient to build systems
Note: Main unit cannot operate alone. Please select and purchase the test lead
options appropriate for your application separately.
±2 % rdg. ±5 dgt. : at 25/ 50/ 100 V [0 to 20 MΩ], 250 V [0 to 100 MΩ],
Basic accuracy
500/ 1000 V [0 to 999 MΩ]
Measurement speed Fast: 10 times/s, Slow:1 time/s, selectable, Response times: less than 0.5 sec
LED
Display
Testing voltage, Limit level value of comparator , Testing mode, Beep sound of
decision, Testing time, Delay time, Resistance range, Measurement speed
Internal memory
Number of memory: Max. 10 (External control to save or load)
Key press: Select lower limit value from designated options
Comparator setting
RS-232C: Set optional lower limit value within measurement range
PASS: Measurement value ≥ lower limit, FAIL: Measurement value < lower
Judgement prolimit, Beep sound, PASS/FAIL display, signal output to external I/O
cess
After measurement START is initiated and waiting time (0.35 s max.) +
Test duration timer
designated test duration elapses. Test duration: 0.5 to 99 s
After measurement START is initiated and until waiting time (0.35 s max.)
Delay time timer
+ designated delay time elapses. Delay time: 0.1 to 99 s
DC +4 V f.s.
Analog output
RS-232C (Measurement value printing is possible with connect the Printer 9442),
Interface
External I/O (External control input, Judgment result)
100 to 240 V AC, 50/60 Hz, 15 VA max.
Power supply
Dimensions and mass 215 mm (8.46 in)W × 61 mm (2.40 in)H × 213 mm (8.39 in)D, 1.1 kg (38.8 oz)
Instruction Manual ×1, Power cord ×1
Accessories
Printer options
CONNECTION CORD SWITCHED PROBE RS-232C CABLE 9637
For the PC, 9pin - 9pin,
9299
Alligator clip set, 1.2 m L9257
(3.94 ft) length
1.2 m (3.94 ft) length
80 cm (2.62 ft) length
AC ADAPTER
CONNECTION
CABLE 9444
RECORDING
PAPER 1196
For printing numerical 9443-02
For the Printer 9442, For the Printer 9442,
values 112 mm (4.41 in) For the Printer 9442, 9 pin - 9 pin, 1.5 m
112 mm (4.41 in) × 25 m
paper width
EU type
(4.92 ft) length
(82.03 ft), 10 rolls/set
RS-232C CABLE 9638
For the PC, 9pin - 25pin,
cross, 1.8m (5.91 ft) length cross, 1.8m (5.91 ft) length
OUTPUT CORD 9094
3.5 mm (0.14in) dia. mini
plug to banana, 1.5m (4.92ft)
length, Not CE markde
Other
PC communication
TEST LEAD L9787
PRINTER 9442
SAFETY TEST DATA
MANAGEMENT SOFTWARE 9267
For PC control application
software
55
Power Analyzers
Maximizing the Efficiency of Energy Conversion
POWER ANALYZER 3390-10
■ Basic specifications (Where different from Model 3390. Accuracy guaranteed for 1 year)
Voltage: ±0.05 % rdg. ±0.05 % f.s.
Current: ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dediBasic accuracy
(45Hz to 66Hz)
cated sensors)
Active power: ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with
dedicated sensors)
Note: Accuracy for the high accuracy Models 3390-10 and Current Sensors are not defined
individually. Please use these products in combination to obtain ±0.1% accuracy.
marked
Accessories
Other
Instruction Manual for Model 3390-10 ×1, Instruction Manual for Model 3390
×1, Power cord ×1, Measurement Guide ×1, USB cable ×1, Measurement cable
label sheet ×2, D-sub connector ×1 (when 9792 or 9793 is installed)
Same as Model 3390
Note: Data sheets for specific combinations of Model 3390-10 and current sensors available upon request.
Note: Optional current sensor and voltage cord are necessary to measure current or power parameters.
Options other than current sensors are the same as for the 3390
*Use with the 3390-10 only, Dedicated Pull-through Current Sensors (High Accuracy Models)
Current measurement
• Super precise ±0.1% accuracy model to meet the demanding needs of today
• Switch from one range to another and still maintain the same ±0.1% accuracy on
all ranges
• Guaranteed accuracy period is extended another 6 months from the basic Model
3390 (other functions remain the same)
• Advanced motor analysis functions (measures the electric angle and supports
vector control)
• High-speed harmonic analysis function (50 ms data refresh rate)
• Noise analysis function for inverters (using FFT analysis technology)
• Inverter power measurement with the convenience of clamp on sensors
AC/DC CURRENT
SENSOR 9709-10
AC/DC CURRENT
SENSOR CT6863-10
AC/DC CURRENT
SENSOR CT6862-10
CAT III 1000 V, 500 A AC/DC
rated current, DC to 100 kHz
response, φ 36 mm (1.42 in) core
dia., 3 m (9.84 ft) cord length
CAT III 1000 V, 200 A AC/DC
rated current, DC to 500 kHz
response, φ 24 mm (0.94 in) core
dia., 3 m (9.84 ft) cord length
CAT III 1000 V, 50 A AC/DC
rated current, DC to 1 MHz
response, φ 24 mm (0.94 in) core
dia., 3 m (9.84 ft) cord length
Power
Analyzers
Measure the Secondary Side of Inverters with Cutting Edge Technology
POWER ANALYZER 3390
■ Basic specifications (Accuracy guaranteed for 6 months or 1 year)
Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire,
Voltage 4 channels, Current 4 channels, Isolated between each channel
Voltage, Current, Voltage/current waveform peak, Active power, Reactive power,
Apparent power, Power factor, Phase angle, Frequency, Current integration, Power
integration, Efficiency, Loss, Voltage/current ripple factor
Noise measurement (FFT processing): RMS spectrum of voltage/current
Measurement items Harmonic measurement: RMS value, Content factor, Phase angle, Total distortion,
Disequilibrium factor
Additional functions (With optional 9791 or 9793 installed in the main unit) :
Torque, Rotation, Frequency, Slip, or Motor output
Harmonic measure- Input: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz,
Number of harmonic orders: Max. 100th order
ment
Number of channels: 1 ch (select one channel from CH1 to CH4),
Noise measurement Maximum analysis frequency: 100 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz
Measurement line
type
marked
Voltage range: 15 to 1500 V, 7 ranges
Current range: 400 mA to 500 A (depends on current sensor, 20A/ 50A/ 200A/ or 500A rated)
Power range: 6.0000 W to 2.2500 MW (depends on combination of voltage and current range)
Frequency range: 0.5 Hz to 5 kHz
Voltage: ±0.05 % rdg. ±0.05 % f.s.
Current: ±0.05 % rdg. ±0.05 % f.s. + current sensor accuracy
Basic accuracy
Active power: ±0.05 % rdg. ±0.05 % f.s. + current sensor accuracy
Synchronization frequency range 0.5 Hz to 5 kHz
DC, 0.5 Hz to 150 kHz
Frequency band
50 ms (For harmonic measurement, depends on the synchronization frequency when less than 45 Hz)
Data update rate
Display refresh rate 200 ms (Independent of internal data update rate; waveform and FFT depend on the screen)
Data save interval OFF, 50 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes, 15 settings
External interfaces LAN, USB (communication/ memory), RS-232C, CF card, Synchronization control
100 to 240 V AC, 50/60 Hz, 140 VA max.
Power supply
Dimensions and mass 340 mm (13.39 in)W × 170 mm (6.69 in)H × 157 mm (6.18 in)D, 4.8 kg (169.3 oz)
Instruction Manual ×1, Power cord ×1, Measurement Guide ×1, USB cable ×1,
Accessories
Measurement cable label sheet ×2, D-sub connector × 1 (when 9792 or 9793 is installed)
Measurement
range
• Advanced motor analysis functions (measures the electric angle and supports
vector control)
• High-speed harmonic analysis function (50 ms data refresh rate)
• Noise analysis function for inverters (using FFT analysis technology)
• Inverter power measurement with the convenience of clamp on sensors
• Achieve the same superior accuracy as direct wiring method meters at maximum
±0.16% (when combined with the 9709)
• LAN, USB, and CF card - a rich array of interfaces
Note: Optional current sensor is necessary to measure current or power parameters.
MOTOR TESTING
OPTION 9791
D/A OUTPUT OPTION
9792
MOTOR TESTING & D/A
OUTPUT OPTION 9793
Factory-installed option - not user
installable, built in the main unit
Factory-installed option - not user
installable, built in the main unit
Factory-installed option - not user
installable, built in the main unit
Current measurement
AC/DC CURRENT
SENSOR CT6865
AC/DC CURRENT
SENSOR 9709
AC/DC CURRENT
SENSOR CT6863
CAT III 1000 V, 1000 A
AC/DC rated current, DC to
20 kHz response, φ 36 mm
(1.42 in) core dia., 3 m (9.84
ft) cord length
CAT III 1000 V, 500 A AC/
DC rated current, DC to
100 kHz response, φ 36 mm
(1.42 in) core dia., 3 m (9.84
ft) cord length
CAT III 1000 V, 200 A AC/
DC rated current, DC to
500 kHz response, φ 24 mm
(0.94 in) core dia., 3 m (9.84
ft) cord length
Attaches to the tip of the Cord
VOLTAGE CORD L9438-50 L4930/9197/9322 or other,
Black/ Red, 3 m (9.84 ft) length,
Alligator clip ×2
CAT III 1000 V, 196 mm (7.72
in) length
Other options
Voltage measurement
GRABBER CLIP 9243
AC/DC CURRENT
SENSOR CT6862
Storage media
Factory-installed options
56
*Must specify when ordering
UNIVERSAL CLAMP
ON CT 9279
CAT III 1000 V, 50 A AC/ 600 Vrms insulated wire, 500
DC rated current, DC to 1
A AC/DC rated current, DC
MHz response, φ 24 mm
to 20 kHz response, φ 40 mm
(0.94 in) core dia., 3 m (9.84 (1.57 in) core dia., 3 m (9.84 ft)
ft) cord length
cord length, Not CE marked
Supplied with
PC Card adapter
PC Card Precaution PC CARD 2G 9830
(2 GB capacity)
PC CARD 1G 9729
(1 GB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
Use only PC Cards sold
by HIOKI. Compatibility
and performance are
not guaranteed for PC
cards made by other
manufacturers. You may
be unable to read from or
save data to such cards.
UNIVERSAL CLAMP UNIVERSAL CLAMP CLAMP ON SENSOR
ON CT 9278
ON CT 9277
9272-10
CAT II 600 Vrms, CAT III
CAT II 600 Vrms, CAT III CAT III 600 Vrms, 20 A/200 A
300 Vrms, 200 A AC/DC
300 Vrms, 20 A AC/DC
AC rated current, 1 Hz to 100
rated current, DC to 100 kHz rated current, DC to 100 kHz kHz response, φ 46 mm (1.81
response, φ 20 mm (0.79 in)
response, φ 20 mm (0.79 in)
in) core dia., 3 m (9.84 ft) cord
core dia., 3 m (9.84 ft) cord
core dia., 3 m (9.84 ft) cord
length
length
length
RACK MOUNT BRACKETS
Please contact HIOKI for rack
mounting
CONNECTION CORD L9217 LAN CABLE 9642
CONNECTION CABLE
Cord has insulated BNC connectors Straight Ethernet cable, supplied 9683
at both ends, signal output use, 1.6 m with straight to cross conversion For synchronization, cable
(5.25 ft) length
adapter, 5 m (16.41 ft) length
length 1.5 m (4.92 ft)
CARRYING CASE 9794
For the 3390, hard trunk type
Power Meters
Identify Your Power Condition to Reveal Energy Saving Ideas
CLAMP ON POWER LOGGER PW3360-20, PW3360-21
marked
n Basic specifications (Accuracy guaranteed for 1 year)
Measurement line &
number of circuits
50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases
3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
Voltage/current RMS, voltage/current fundamental wave value, voltage /current fundamental
wave phase angle, frequency, voltage waveform peak (absolute value), current waveform
peak (absolute value), active/reactive/ apparent power, power factor (lag/lead) or displacement power factor (lag/lead), active energy (consumption, regeneration), reactive energy
(consumption, regeneration), active power demand quantity (consumption, regeneration),
Measurement items reactive power demand quantity (lag/lead), active power demand value (consumption, regeneration), reactive power demand value (lag/lead), power factor demand, energy cost
Pulse input
[PW3360-21 only]: Harmonic (level of voltage/current/power, content ratio, phase angle, total
value, THD-F, THD-R), up to 40th order
600 V AC
500.00 mA to 5.0000 kA AC (depends on current sensor in use),
Current ranges
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
300.00 W to 9.0000 MW (Depends on voltage/current combination and measured line type)
Power ranges
Voltage : ±0.3% rdg. ±0.1% f.s
Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Basic accuracy
Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1)
Display update rate 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
SD Memory card, or internal memory at real time
Save destination
Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Measurement value save: Average only / average, maximum, minimum value
[PW3360-21 only]: Harmonic data save: Average only / average, maximum, minimum value in binary format
Save items
Screen copy: BMP form (saved every 5 min. at minimum interval time)
Waveform save: Binary waveform data
Voltage ranges
Clamp sensors : Sold separately
• CLAMP ON POWER LOGGER PW3360-20 (Main unit only)
• CLAMP ON POWER LOGGER PW3360-21 (Harmonic analysis model)
Note: At least one optional current sensor is necessary to measure current or power parameters. To store measurement data, use only the guaranteed SD cards sold by HIOKI.
Interfaces
Functions
Power supply
Dimensions and
mass
Voltage measurement
Accessories
*L9438-53 is bundled with the PW3360-20/-21
VOLTAGE CORD L9438-53
Black/ Red/ Yellow/ Blue, 3 m (9.84 ft)
length, Alligator clip ×4
MAGNETIC
ADAPTER 9804-01
MAGNETIC
ADAPTER 9804-02
Attaches to the tip of the
Voltage Cord, Red ×1
Attaches to the tip of the
Voltage Cord, Black ×1
Power supply
100 to 240 V AC
VOLTAGE LINE POWER
ADAPTER PW9003
For PW3360s, supplies power from
measurement lines, up to 240V AC
BATTERY SET PW9002 BATTERY PACK 9459
Battery case and Battery
Pack 9459 Set
Other options
POWER LOGGER VIEWER SF1001
LAN CABLE 9642
Easy graphical processing of measurement
data saved with the PW3360 series on a PC
Straight Ethernet cable, supplied
with straight to cross conversion
adapter, 5 m (16.41 ft) length
SD memory card
HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as
removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power
consumption, Isolated open-collector signal
Connection check, Quick Set navigation guide, clock, pulse input
AC adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter)
Battery pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 8 hours of continuous use (with back light off)
180 mm (7.09 in)W × 100 mm (3.94 in)H × 48 mm (1.89 in)D, 550 g (19.4 oz) without PW9002
180 mm (7.09 in)W × 100 mm (3.94 in)H × 67.2 mm (2.65 in)D, 830 g (29.3 oz) with PW9002
Voltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual
×1, Measurement guide ×1, Color spiral tubes ×1 set: red, yellow, blue/two each, for
color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5
n Measurement examples
*Z1006 is bundled with the PW3360-20/-21. Model 9459 is a replacement battery pack included with the Battery Set PW9002.
AC ADAPTER
Z1006
Power Meters
• Supports single to three-phase, 4-wire circuits
• Measure up to 780V with a 1000V display range
• Simultaneously measure up to three single-phase, 2-wire circuits (in the same
power system)
• Broadly applicable for many jobs, including leakage current measurement (An
optional clamp-on leakage sensor supports measurements as low as 50 mA)
• Store months of data on SD cards
• The QUICK SET function guides you in making the right connections
• Choose PW3360-21 for harmonic measurements up to the 40th order
n Where no AC power is available
Battery* power provides about eight
hours of continuous operation. In addition, a Voltage Line Power Adapter*
is available to power the PW3360
series from the measurement lines.
NiMH, Charges while
installed in the main unit
n In severe temperature environments
The operating temperature range
extends from –10°C (14°F) to 50°C
(122°F). Even under battery operation,
measurements can be performed from
0 °C (32°F) to 40°C (104°F)
n To reduce energy usage in factories
The pulse input function can be used
to record power data and production
volume counts simultaneously. The
power data and pulse volume (production volume) information are useful for
unit cost production management.
CARRYING CASE C1005
For PW3360s, for storing
options
Storage media
SD Card Precaution
SD MEMORY CARD
2GB Z4001
For storing measurement
data
Use only the SD Card Z4001 sold
by HIOKI. Compatibility and performance are not guaranteed for
SD cards made by other manufacturers. You may be unable to read
from or save data to such cards.
Common options for PW3360-20/-21, 3197, 3196, 3169-20/-21 (CLAMP ON SENSORS)
For power or load current measurement (1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)
φ 254 mm
(10 in)
CLAMP ON SENSOR 9694 CLAMP ON SENSOR 9660 CLAMP ON SENSOR 9661 FLEXIBLE CLAMP ON
5A AC rated current, φ 15 mm 100A AC rated current, φ 15 mm 500A AC rated current, φ 46 mm SENSOR CT9667
(0.59 in) core dia., 3 m (9.84 ft)
length
(0.59 in) core dia., 3 m (9.84 ft)
length
(1.81 in) core dia., 3 m (9.84 ft)
length
Common options for PW3360-20/-21, 3197
For leak current measurement (not capable of power measurement)
CLAMP ON LEAK
SENSOR 9675
10A AC rated current, φ 30
mm (1.18 in) core dia., 3 m
(9.84 ft) length
CLAMP ON LEAK SENSOR
9657-10
10A AC rated current, φ 40
mm (1.57 in) core dia., 3 m
(9.84 ft) length
CLAMP ON SENSOR 9669 CLAMP ON SENSOR 9695-02
1000A AC rated current, φ 55
50A AC rated current, φ 15 mm
mm (2.17 in) core dia., 3 m (9.84 (0.59 in) core dia., Requires the
5000/500 A AC rated current, φ
254 mm (10.0 in) core dia., Cable ft) length
Connection cord 9219
length: Between sensor - box 2 m
(6.56 ft), Output cable 1 m (3.28 ft)
CLAMP ON SENSOR 9695-03 CONNECTION CORD
100A AC rated current, φ 15 mm 9219
(0.59 in) core dia, Requires the
Connection cord 9219
Connect with the 9695-02/
-03, Output BNC terminal
Clamp sensor adapter
CLAMP ON ADAPTER
9290-10
CT for 1000A AC, secondary
current 1/10 of primary
57
Power Meters/Power Quality Analyzers
The New World Standard for Power Quality Analysis, with recording & analyzing according to Class A requirements for PQAs
POWER QUALITY ANALYZER PW3198
■ Basic specifications (Accuracy guaranteed for 1 year)
Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase
4-wire plus one extra input channel (must be synchronized to reference channel
during AC/DC measurement)
Measurement line
type
Voltage measurement: 600.00 V rms
Transient measurement 6.0000 kV peak
500.00 mA to 5.0000 kA AC (depends on current sensor in use)
Voltage: ±0.1% of nominal voltage
Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Voltage ranges
Current ranges
Basic accuracy
marked
Clamp sensors : Option
Power
Analyzers
• Verify power problems in accordance with the IEC61000-4-30 Class A standard
• High accuracy and continuous gapless recording
(V: ±0.1% of nominal voltage, A and W: ±0.2% rdg. ±0.1% f.s.)
• CAT IV 600V - safe enough for incoming power lines
• Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
• Wide dynamic range from low voltages up to 1300V (3P4W line-to-line voltage)
• Maximum 6000V transient overvoltage up to 700kHz
• LAN, USB and SD card interfaces
• Optional GPS BOX for synchronizing multiple devices
• PW3198 (main unit only)
• PW3198-90 (Set model with the PQA-HiView pro 9624-50)
Note: Voltage can be measured with the main unit alone. An optional current sensor is necessary to measure current or power parameters. Use the PQA-HiView pro 9624-50 (version
2.00 or later) with a PC to analyze the data collected to the SD card.
1. Transient over voltage : 2 MHz sampling
2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz
3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
Current (1/2) RMS: half-cycle calculation
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. Frequency: Calculated as 10 or 12 cycles,40 to 70 Hz
9. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz
Measurement items 10. Voltage waveform peak, Current waveform peak
11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy,
Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor,
Current unbalance factor (negative-phase, zero-phase)
12. High-order harmonic component (voltage/ current): 2 kHz to 80 kHz
13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders
14. Harmonic voltage-current phase angle: 1th to 50 th orders
15. Total harmonic distortion factor (voltage/ current)
16. Inter harmonic (voltage/ current): 0.5 Hz to 49.5 Hz
17. K Factor (multiplication factor)
18. IEC Flicker, Δ V10 Flicker
55 weeks (with repeated recording set to [1 Week], 55 iterations)
35 days (with repeated recording set to [OFF])
SD/SDHC card, RS-232C, LAN (HTTP server funtion), USB2.0
Interfaces
6.5-inch TFT color LCD (640 × 480 dots)
Display
AC adapter Z1002 (12 V DC, Rated power supply 100 V AC to 240 V AC, 50/60 Hz)
Power supply
Battery pack Z1003 (Ni-MH 7.2 V DC 4500 mAh)
300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D (excluding protrusions),
Dimensions and mass
2.6 kg (91.7 oz) (including battery pack)
Instruction manual ×1, Measurement guide ×1, Voltage cord L1000 ×1 set (Red/Yellow/
Blue/Gray, each 1, Black ×4, Alligator clip ×8), Spiral tube ×20, Input Cable Labels ×1, AC
Accessories
adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1,
SD memory card 2GB Z4001 ×1
Record
PW3198 Options in Detail
For power or load current measurement (1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)
Current measurement
FLEXIBLE CLAMP ON
CLAMP ON SENSOR CLAMP ON SENSOR CLAMP ON SENSOR SENSOR CT9667
CLAMP ON SENSOR
9694
9660
9661
5000/500 A AC rated current, φ 254 mm 9669
5A AC rated current, φ 15
mm (0.59 in) core dia., 3 m
(9.84 ft) length
100A AC rated current, φ 15 500A AC rated current, φ 46
mm (0.59 in) core dia., 3 m
mm (1.81 in) core dia., 3 m
(9.84 ft) length
(9.84 ft) length
CLAMP ON LEAK
SENSOR 9657-10
10A AC rated current,
φ 30 mm (1.18 in) core
dia., 3 m (9.84 ft) length
10A AC rated current,
φ 40 mm (1.57 in) core
dia., 3 m (9.84 ft) length
CLAMP ON
ADAPTER 9290-10
CT for 1000A AC,
secondary current 1/10
of primary
CLAMP ON AC/DC
SENSOR CT9691-90
CLAMP ON AC/DC
SENSOR CT9692-90
CLAMP ON AC/DC
SENSOR CT9693-90
DC to 10kHz (-3dB), 100A, Output
DC to 20kHz (-3dB), 200A, Output
DC to 15kHz (-3dB), 2000A, Output
0.1 V/f.s., Cord length 2 m (6.56 ft)
0.2 V/f.s., Cord length 2 m (6.56 ft)
0.2 V/f.s., Cord length 2 m (6.56 ft)
Voltage measurement
*The L1000 is bundled
GRABBER CLIP 9243
WIRING ADAPTER WIRING ADAPTER Attaches to the tip of the Cord
L4930/9197/9322 or other, CAT III
PW9001
Red/ Yellow/ Blue/ Gray each 1, Black 4, PW9000
VOLTAGE CORD L1000
Alligator clip ×8, 3m (9.84ft) length
For three-phase 3-wire
*The Z1002, Z1003 are bundled
1000 V, 196 mm (7.72 in) length
SD Card Precaution
Use only the SD Card
Z4001 sold by HIOKI.
Compatibility and perforSD MEMORY CARD mance are not guaranteed
for SD cards made by
2GB Z4001
For storing measure- other manufacturers. You
ment data
may be unable to read from
or save data to such cards.
Other options
BATTERY PACK
Z1003
For three-phase 4-wire
MAGNETIC ADAPTER MAGNETIC ADAPTER
9804-01
9804-02
Attaches to the tip of the
Voltage Cord, Red ×1
Attaches to the tip of the
Voltage Cord, Black ×1
*The Z4001 is bundled
Storage media
Power supply
AC ADAPTER
Z1002
For main unit, 100 to NiMH, Charges while
240 V AC
installed in the main unit
58
For clamp sensor
Current measurement
CLAMP ON LEAK
SENSOR 9675
CONNECTION
CORD 9219
(10.0 in) core dia., Cable length: Between 1000A AC rated current, φ 55 mm 50A AC rated current, φ 15 mm 100A AC rated current, φ 15 mm Connect with the 9695-02/
(0.59 in) core dia., Requires the (0.59 in) core dia, Requires the
-03, Output BNC terminal
sensor - box 2 m (6.56 ft), Output cable 1 (2.17 in) core dia., 3 m (9.84 ft)
length
Connection cord 9219
Connection cord 9219
m (3.28 ft)
Adapter
Leak current
For leak current measurement (not capable of power measurement)
CLAMP ON SENSOR CLAMP ON SENSOR
9695-02
9695-03
CARRYING
CASE C1001
GPS BOX
PW9005
PQA-HiVIEW PRO LAN CABLE 9642
Straight Ethernet cable,
9624-50
To synchronize the Analyze data on the
supplied with straight to
PW3198 clock to
UTC
PC, Convenient report
creation function
cross conversion adapter,
5 m (16.41 ft) length
Soft type, Includes
compartment for
options
CARRYING
CASE C1002
For the PW3198, hard
trunk type, Includes
compartment for
options
Power Meters/Power Quality Analyzers
The most comprehensive portable PQA on the market
POWER QUALITY ANALYZER 3197
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
[Voltage] 600.0 V AC, [Current] 500.0 mA to 5.000 kA AC (depends on current sensor in use),
Measurement range
[Power] 300.0 W to 9.00 MW (depends on combination of current range and line type)
Voltage: ±0.3 % rdg. ±0.2 % f.s.
Current: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy
Basic accuracy
Active power: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy (at power factor=1)
marked
Clamp sensors : Option
• Single-phase 2-wire/single-phase 3-wire/three-phase 3-wire/three-phase 4-wire
• Catch power quality problems on the fly, before they catch you
• Record measurement data on internal memory for easy transfer to a PC via USB
• Analyze measurement data on a bundled PC aplication software
50 event waveforms, 20 event voltage fluctuation graphs, 1 inrush current
Number of
Recordable Events graph, 1000 event counts
USB 2.0 (Communication with the PC)
Interfaces
4.7-inch color STN LCD
Display
AC adapter 9418-15 (100 - 240 V, 50/60 Hz), Battery pack 9459, Continuous use 6 hr
Power supply
(LCD Back-light auto-OFF 5 min.), 23 VA max.
Dimensions and mass 128 mm (5.04 in)W × 246 mm (9.69 in)H × 63 mm (2.48 in)D, 1.2 kg (42.3 oz) (with Battery pack)
Accessories
AC ADAPTER
9418-15
NiMH, Charges while
installed in the main unit 100 to 240V AC
PQA-HiVIEW PRO
9624-50
Analyze data on the
PC, Convenient report
creation function
Current sensors
Black ×4, 3 m (9.84 ft) length,
Alligator clip ×4
BATTERY PACK
9459
Other options
VOLTAGE CORD L9438-55
Power supply
Voltage measurement
*The 9459, 9418-15 are bundled
*The L9438-55 is bundled
Voltage cord L9438-55 ×1 (Black ×4), AC adapter 9418-15 ×1, Power cord ×1, Battery pack
9459 ×1, Input terminal labels ×1, Input cord labels ×1, Strap ×1, Instruction manual ×1,
Measurement guide ×1, USB Cable ×1, CD-R (Applications software) ×1, Carrying case ×1
Power
Analyzers
Note: Optional current sensor is necessary to measure current or power parameters.
1. RMS Voltage and Current (200 ms calculation)
2. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
3. Current (1/2) RMS: half-cycle calculation
4. Frequency
5. Active Power/ Reactive Power/ Apparent Power/ Power Factor/ Displacement Power Factor/
Active or Reactive Energy Consumption
Measurement items 6. Demand (Active or Reactive power)
7. Up to 50th Harmonic Analysis (Time series measurement or recording is not available)
8. Peak Voltage and Current
9. Total harmonic voltage distortion ratio
10. Voltage Unbalance Factor
11. K Factor (Time series recording is not capable)
12. Total harmonic current distortion ratio (Time series recording is not available)
1. Voltage Swells (Rise), Voltage Dips (Drop), Interruptions: RMS value detected
using voltage (1/2) measured every half cycle
2. Inrush Current: RMS value detected using current (1/2) every half cycle
Event Detection
3. Transient Overvoltage: 50 Vrms or more detection, 10 to 100 kHz
4. Timer: Detect events at preset intervals
5. Manual: Detect events when keys are pressed
*For clamp current sensor options, please see
p.57
Demand measurement up to 4 circuits and simultaneous harmonics analysis
CLAMP ON POWER HiTESTER 3169-20, 3169-21
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement line & Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases
3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit)
number of circuits Note: 50 or 60 Hz, and that share the same voltage line
Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power inteMeasurement items gration, Power factor, Frequency, Harmonic waveform value (up to 40th order)
[Voltage] 150.00 V to 600.00 V AC, 3 ranges, [Current] 500.00 mA to 5.0000 kA AC
Measurement range (depends on current sensor in use), [Power] 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line)
Basic accuracy
AC Voltage: ±0.2 % rdg. ±0.1 % f.s.
AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1)
Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models)
Measurement method Digital sampling, PLL synchronization or 50/60 Hz fixed clock
Display refresh rate 2 times /sec (except when a PC card accessing, or RS-232C communications)
Data save interval
Clamp sensors : Option
•Simultaneously measure demand and harmonic waveforms that share the
same voltage line over 4-circuits
•Data can be saved onto a PC card
•High-speed and continuous processing to measure individual waveforms
•High-speed D/A output for analog graph recording (Model 3169-21)
Note: Optional current sensor is necessary to measure current or power parameters. To storage measurement data, use only the guaranteed PC cards sold by HIOKI
Frequency charac- Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy
(of a 45 to 66 Hz fundamental waveform)
teristics
Error connect check, language selection, display hold, setting backup, power shut
Other functions
off management, key lock, [3169-21 only] D/A output 4 channels, (±5 V DC f.s.)
100 to 240 V AC, 50/60 Hz, 30 VA max.
Power supply
Dimensions and mass 210 mm (8.27 in)W × 160 mm (6.30 in)H × 60 mm (2.36 in)D, 1.2 kg (42.3 oz)
Accessories
Voltage cord L9438-53 ×1 (Black/ Red/ Yellow/ Blue, 3 m (9.84 ft) length, Alligator clip ×4),
Power cord ×1, Instruction manual ×1, Quick start manual ×1, CD-R ×1 (RS-232C interface
operating manual) ×1, Input cord label ×1, Connection cable 9441 ×1 (for the 3169-21 only)
*The L9438-53 is bundled
VOLTAGE CORD L9438-53
MAGNETIC ADAPTER MAGNETIC ADAPTER
9804-01
9804-02
Black/ Red/ Yellow/ Blue, 3 m (9.84 ft) Attaches to the tip of the
Voltage Cord, Red ×1
length, Alligator clip ×4
Attaches to the tip of the
Voltage Cord, Black ×1
Storage media
Voltage measurement
Current measurement
*For clamp current
sensor options,
please see p.57
Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects
Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only)
* PC CARD 2G 9830, PC CARD 1G 9729 : cannot use with
the 3169-20, 3169-21
* Supplied with PC Card adapter
PC Card Precaution
Use only PC Cards sold by HIOKI. Compatibility
and performance are not guaranteed for PC cards
made by other manufacturers. You may be unable to
read from or save data to such cards.
PC CARD 512M 9728
(512 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
*The 9441 is bundled with the 3169-21
AC ADAPTER
RS-232C CABLE RECORDING
9721
PAPER 1196
For printing numerical
9443-02
Mini DIN 9pin to D-sub For the Printer 9442,
values 112 mm (4.41 in) For the Printer 9442, 9pin, straight, 1.5 m
112 mm (4.41 in) × 25 m
paper width
EU type
(4.92 ft) length
(82.03 ft), 10 rolls/set
Other options
Printer options
PRINTER 9442
POWER MEASUREMENT
SUPPORT SOFTWARE 9625
RS-232C CABLE 9612
PC application software with
Time series graph, Daily/ weekly/
monthly report, Harmonic level,
Print
For the PC, Mini DIN 9pin CARRYING CASE 9720-01
CABLE 9440
CABLE 9441
to D-sub 9pin, cross, 1.5 m Soft type, Includes compartment For external I/O, 2 m For D/A output, 2 m
(4.92ft) length
(6.56 ft) length
(6.56 ft) length
for options, for the 3169 series
CONNECTION
CONNECTION
59
Power Meters
Accurately measure devices up to 1,000 V/65 A AC/DC with direct input
POWER METER PW3337, PW3337-01/-02/-03
■ Basic specifications (Accuracy guaranteed for 1 year)
Single-phase 2-wires, single-phase 3-wires, 3-phase 3-wires, 3-phase 4-wires
(voltage / current measurement range set for each wiring mode)
Voltage, Current, Active power, Apparent power, Reactive power, Power factor, Phase
angle, Frequency, Efficiency, Current integration, Active power integration, Integrated
Measurement items time, Voltage waveform peak value, Current waveform peak value, Voltage crest factor,
Current crest factor, Time average current, Time average active power, Voltage ripple
factor, Current ripple factor
Synchronization frequency range: 10 Hz to 640 Hz, Analysis order up to 50th
Harmonic voltage RMS value, Harmonic current RMS value, Harmonic active power, Total
harmonic voltage distortion, Total harmonic current distortion, Voltage fundamental waveform, Current fundamental waveform, Active power fundamental waveform, Apparent
power fundamental waveform, Reactive power fundamental waveform, Power factor
Harmonic parameters fundamental waveform (displacement power factor), Voltage current phase difference fundamental waveform, Interchannel voltage fundamental wave phase difference, Interchannel
current fundamental wave phase difference, Harmonic voltage content % , Harmonic current content % , Harmonic active power content %
Measurement lines
Standard
Standard
-01/-03 Model
marked
(The following parameters can be downloaded as data during PC communication but not displayed: Harmonic
voltage phase angle, Harmonic current phase angle, Harmonic voltage current phase difference)
•Measure DC, and single-phase 2-wire to 3-phase 4-wire with 3-channel input
•For development and production of motors, inverters, power conditioners,
power supplies, and other devices
•High-precision basic accuracy ±0.1 % (*1)
(*1) For complete details, please refer to the specifications
Power Meters
•Wide frequency bandwidth of 0.1 Hz to 100 kHz or DC
•High-current measurement up to 65 A direct input
•Harmonic measurement up to the 50th order with IEC 61000-4-7 compliance
•High-accuracy measurement, even with a low power factor for no-load testing of transformers and motors
•Built-in external sensor input terminals multi-unit measure up to 5000 A AC
•Synchronize up to 8 units for multi-unit measurement
• PW3337 (3ch model)
• PW3337-01 (3ch, GP-IB installed model)
• PW3337-02 (3ch, D/A output installed model)
• PW3337-03 (3ch, GP-IB, D/A output installed model)
Functions
Voltage range: AC/DC 15 V to 1000 V, 7 ranges
Current range: AC/DC 200 mA to 50 A, 8 ranges
Power range: 3.0000 W to 150.00 kW (Depends on combination of voltage and current range)
[Current] No.of displayed digits: 6 digits (from 0.00000 mAh, Polarity-independent integration and Sum value)
[Active power] No.of displayed digits: 6 digits (from 0.00000 mWh, Polarity-independent integration and Sum value)
[Voltage] 2 MΩ, [Current] 1 mΩ or less (direct input)
±0.1% rdg. ±0.1% f.s. (DC)
±0.1% rdg. ±0.05% f.s. (45 Hz to 66 Hz, at Input < 50% f.s.)
±0.15% rdg. (45 Hz to 66 Hz, at 50% f.s. ≤ Input)
5 times per second to 20 seconds (depends on average times settings)
DC, 0.1 Hz to 100 kHz
16 channels (selectable from following items): Level output DC ±2 V, Waveform output 1 V f.s.
Level output, instantaneous waveform output (voltage, current, active power),
Level output (apparent power, reactive power, power factor, or other),
High-speed active power level output
[Rectification method] AC+DC, AC+DC Umn, AC, DC, FND, Auto-range, Average,
VT or CT ratio settings, Synchronized control, MAX/MIN, or other functions
Interfaces
Power supply
Dimensions and mass
Accessories
RS-232C / LAN standard, (-01/-03 model also includes GP-IB)
100 to 240 V AC, 50/60 Hz, 40 VA max.
305 mm (12.01 in)W × 132 mm (5.20 in)H × 256 mm (10.08 in)D, 5.6 kg (197.5 oz)
Instruction manual ×1, Measurement guide ×1, Power cord ×1
Measurement
range
Integration measurement
(Integration time up to 10,000 hours)
Input resistance (50/60 Hz)
Basic accuracy
(Active power)
Display refresh rate
Frequency characteristics
D/A output
(-02/-03 model only)
Accurately measure devices up to 1,000 V/65 A AC/DC with direct input
POWER METER PW3336, PW3336-01/-02/-03
Standard
Standard
-01/-03 Model
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
Single-phase 2-wires, single-phase 3-wires, 3-phase 3-wires, (voltage / curMeasurement lines rent measurement range set for each wiring mode)
Measurement items
Same as the PW3337 series
Harmonic parameters
Voltage range: AC/DC 15 V to 1000 V, 7 ranges
Measurement
Current range: AC/DC 200 mA to 50 A, 8 ranges
range
Power range: 3.0000 W to 100.00 kW (Depends on combination of voltage and current range)
Other specifications Same as the Model PW3337 series
Dimensions and mass 305 mm (12.01 in)W × 132 mm (5.20 in)H × 256 mm (10.08 in)D, 5.2 kg (183.4 oz)
• PW3336 (2ch model)
• PW3336-01 (2ch, GP-IB installed model)
• PW3336-02 (2ch, D/A output installed model)
• PW3336-03 (2ch, GP-IB, D/A output installed model)
•Measure DC, and single-phase 2-wire to 3-phase 3-wire with 2-channel input
•Other characteristics are the same as the PW3337 series
Common options for the POWER METER PW3337, PW3336 series
CLAMP ON SENSOR 9660
CLAMP ON SENSOR 9661
FLEXIBLE CLAMP ON SENSOR CT9667
CLAMP ON SENSOR 9669
100A AC rated current, φ 15 mm (0.59 500A AC rated current, φ 46 mm (1.81 5000/500 A AC rated current, φ 254 mm (10.0 in) core dia., Cable
1000A AC rated current, φ 55 mm
in) core dia., 3 m (9.84 ft) length
in) core dia., 3 m (9.84 ft) length
length: Between sensor - box 2 m (6.56 ft), Output cable 1 m (3.28 ft) (2.17 in) core dia., 3 m (9.84 ft) length
SENSOR UNIT 9555-10
Power supply for the 9270 series,
9709, CT6860 series, single sensor connectable
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, signal
output use, 1.6 m (5.25 ft)
length
Requires Sensor unit 9555-10 and Connection cord L9217 (1 sensor necessary for single-phase measurement, and 2 or 3 sensors required for 3-phase measurements)
AC/DC CURRENT
SENSOR CT6865
AC/DC CURRENT
SENSOR 9709
AC/DC CURRENT
SENSOR CT6863
AC/DC CURRENT
SENSOR CT6862
UNIVERSAL CLAMP ON
CT 9279
UNIVERSAL CLAMP ON
CT 9278
UNIVERSAL CLAMP ON CLAMP ON SENSOR
CT 9277
9272-10
CAT II 600 Vrms, CAT III 300
600 Vrms insulated wire, 500 A AC/ CAT II 600 Vrms, CAT III 300
CAT III 1000 V, 1000 A AC/
CAT III 1000 V, 500 A AC/DC CAT III 1000 V, 200 A AC/DC CAT III 1000 V, 50 A AC/DC
Vrms, 200 A AC/DC rated current, Vrms, 20 A AC/DC rated current,
DC rated current, DC to 20 kHz
DC rated current, DC to 20 kHz rated current, DC to 100 kHz
rated current, DC to 500 kHz
rated current, DC to 1 MHz
DC to 100 kHz response, φ 20 mm DC to 100 kHz response, φ 20 mm
response, φ 36 mm (1.42 in) core response, φ 36 mm (1.42 in) core response, φ 24 mm (0.94 in) core response, φ 24 mm (0.94 in) core response, φ 40 mm (1.57 in) core dia.,
(0.79 in) core dia., 3 m (9.84 ft) cord (0.79 in) core dia., 3 m (9.84 ft) cord
3 m (9.84 ft) cord length, Not CE
dia., 3 m (9.84 ft) cord length
dia., 3 m (9.84 ft) cord length
dia., 3 m (9.84 ft) cord length
dia., 3 m (9.84 ft) cord length
length
length
marked
CAT III 600 Vrms, 20 A/200 A
AC rated current, 1 Hz to 100 kHz
response, φ 46 mm (1.81 in) core dia.,
3 m (9.84 ft) cord length
Synchronize Multiple Units
LAN CABLE 9642
Straight Ethernet cable,
supplied with straight to
cross conversion adapter, 5
m (16.41 ft) length
RS-232C CABLE
9637
RS-232C CABLE
9638
GP-IB CONNECTOR
CABLE 9151-02
For the PC, 9pin - 9pin, For the PC, 9pin - 25pin, 2m (6.56 ft) length
cross, 1.8m (5.91 ft)
cross, 1.8m (5.91 ft)
length
length
Other options
PC communication
60
Power supply for sensor
Current measurement [Type 1] Current measurement [Type 2]
Can be connected to the current sensor input terminals (1 sensor necessary for single-phase measurement, and 2 or 3 sensors required for 3-phase measurements)
CONNECTION CORD 9165
Cord has metallic BNC connectors at both ends, signal
output use, 1.5 m (4.92 ft) length, Not CE marked
Power Meters
Solves All of your Energy Consumption Testing Needs
AC/DC POWER HiTESTER 3334, 3334-01
■ Basic specifications (Accuracy guaranteed for 3 years)...1-year and 3-year accuracies defined separately
Measurement lines Single-phase/ two-wires
Voltage, Current, Active power, Apparent power, Power factor, Frequency,
Measurement items
Integration (current, active power), Waveform peak (voltage and current)
[Voltage] AC/DC 15.000/ 30.00/ 150.00/ 300.0 V
Measurement
[Current] AC/DC 100.00/ 300.0 mA, 1.0000/ 3.000/ 10.000/ 30.00 A
ranges
[Power] 1.5000 W to 9.000 kW (combination of voltage and current ranges)
[Current] No. of displayed digits: 6 digits (from 0.00000 mAh, Polarity-independent
Integration meaintegration and Sum value)
surement
[Active power] No. of displayed digits: 6 digits (from 0.00000 mWh, PolarityIntegration time up to
-01 Model
marked
10,000 hours
[Voltage] 2.4 MΩ, [Current] 10 mΩ or less (direct input)
Basic accuracy
±0.1% rdg. ±0.2% f.s. (DC), ±0.1% rdg. ±0.1% f.s. (45 Hz to 66 Hz)
Note: Provided accuracy of 1 Year, typical value
(50/60 Hz)
•Compatible with the SPECpower® benchmarking for server’s power
consumption
® SPECpower is a registered trademark of Standard Performance Evaluation Corporation
Display refresh rate 5 times/s
Frequency characteristics DC, 45 Hz to 5 kHz
Parameter output representation: voltage, current and power (3 simultaneous
Waveform output
channels), Output voltage: 1 V DC f.s.
Parameter output representation: voltage, current active power and selected 1 item (4
Analog output
simultaneous channels), Selected 1 item from apparent power, power factor, current
(D/A output)
integration, active power integration, Output voltage: ±2 V DC f.s.
Rectification method switchable between AC+DC (True RMS), DC (simple average), AC
Functions
(True RMS), Wave peak measurement, VT or CT ratio settings, Average function
RS-232C included as standard, GP-IB (Model 3334-01 only)
Interfaces
100 V to 240 V AC, 50/60 Hz, 20 VA max.
Power supply
Dimensions and mass 210 mm (8.27 in)W × 100 mm (3.94 in)H × 245 mm (9.65 in)D, 2.5 kg (88.2oz)
Instruction manual ×1, Power cord ×1
Accessories
PC communication
RS-232C CABLE
9637
RS-232C CABLE
9638
Power Meters
•DC measurement mode, AC, and AC+DC measurement
•Integration function for current and power
•±0.2% high basic accuracy
•Extended Period of Guaranteed Accuracy of 3 Years
•Complete Accuracy Over a Wide Input Range
independent integration and Sum value)
Input resistance
GP-IB CONNECTOR
CABLE 9151-02
For the PC, 9pin - 9pin,
For the PC, 9pin - 25pin, 2 m (6.56 ft) length
cross, 1.8m (5.91 ft) length cross, 1.8m (5.91 ft) length
User-Friendly Power Measuring Device for Production and Inspection Lines
POWER HiTESTER 3333, 3333-01
-01 Model
marked
■ Basic specifications (Accuracy guaranteed for 3 years or 1 year)
Measurement lines Single-phase 2-wires
Measurement items Voltage, Current, Active power, Apparent power, Power factor
[Voltage] 200 V AC (300 V Max.)
Measurement range [Current] 50/ 200/ 500 mA, 2/ 5/ 20 A AC (30 A Max.)
[Power] 10.000 W to 4.000 kW (combination of voltage and current ranges)
Input resistance
[Voltage] 2.4 MΩ, [Current] 7 mΩ or less (direct input)
(50/60 Hz)
[Guaranteed for 1 year, Voltage, Current, Active power] ±0.1 % rdg. ±0.1 % f.s.
Basic accuracy
(45 Hz to 66 Hz, input current 20 A or less)
[Guaranteed for 3 years, Voltage, Current, Active power] ±0.1 % rdg. ±0.2 % f.s.
(45 Hz to 66 Hz, input current 20 A or less)
•Accuracy that can only be realized with a digital display
•±0.2% basic accuracy (±0.1% rdg. ±0.1% f.s.)
•50mA to 20A AC current range
•Print out with the 9442 and RS-232C interface
Display refresh rate 5 times/s
Frequency charac45 Hz to 5 kHz
teristics
3 channels outputs simultaneously for voltage, current, active power
D/A output
+2 V DC f.s.
Scaling (VT, CT ratio settings), Average function
Functions
RS-232C standard, GP-IB (Model 3333-01 only)
Interfaces
Power supply
100 to 240 V AC, 50/60 Hz, 20 VA max.
Dimensions and mass 160 mm (6.30 in)W × 100 mm (3.94 in)H × 227 mm (8.94 in)D, 1.9 kg (67.0 oz)
Instruction manual ×1, Power cord ×1
Accessories
RS-232C CABLE
9638
GP-IB CONNECTOR
CABLE 9151-02
For the PC, 9pin - 9pin,
For the PC, 9pin - 25pin, 2 m (6.56 ft) length
cross, 1.8m (5.91 ft) length cross, 1.8m (5.91 ft) length
Printer options
PC communication
RS-232C CABLE
9637
PRINTER 9442
AC ADAPTER
For printing numerical 9443-02
values 112 mm (4.41 in) For the Printer 9442,
paper width
EU type
CONNECTION
CABLE 9444
For the Printer 9442,
9 pin - 9 pin,
1.5 m (4.92 ft) length
RECORDING
PAPER 1196
For the Printer 9442,
112 mm (4.41 in) × 25 m
(82.03 ft), 10 rolls/set
61
Power Meters
Measure very low effective power, for stand-by mode of household appliances
POWER HiTESTER 3332
■ Basic specifications (Accuracy guaranteed for 6 months)
Measurement lines Single-phase 2-wires
Voltage, Current, Current peak, Active power, Apparent power, Reactive
Measurement items power, Power factor, Phase angle, Frequency, Power integration, Current
integration
[Voltage] 15/ 30/ 60/ 150/ 300/ 600 V AC
[Current] 1/ 2/ 5/ 10/ 20/ 50/ 100/ 200/ 500 mA, 1/ 2/ 5/ 10/ 20/ 50 A AC
Measurement ranges
[Power] 15.000 mW to 30.000 kW (combination of voltage and current ranges)
[Frequency] Auto/ 500 Hz/ 100 kHz (select voltage or current)
Input resistance (50/60 Hz) [Voltage] 2 MΩ, [Current] 2 mΩ or less (direct input)
±0.1 % rdg. ±0.1 % f.s. (45 Hz to 66 Hz)
Basic accuracy
Display refresh rate 5 times/s
Frequency
1 Hz to 100 kHz
characteristics
Data update time: 5 times/s, Measurement range: 0.00000 m to ±999999
Integration
MAh/MWh, (integration time up to 10,000 hours)
measurement
Current I (displays max. absolute value), Effective input range: Six times the
Wave peak
current range, or Max. 90 A peak
measurement
Number of channel: 1 ch,
Output items: Voltage, Current, Current peak, Active power, Apparent
D/A output
power, Reactive power, Power factor, Phase angle, Frequency, Integration
Voltage, Current, Power simultaneously, DC ±5 V f.s.
Analog output
Voltage, Current simultaneously (waveform output), 1 Vrms f.s.
Monitor output
Comparator function for 2 measurement items (Decision for Hi /In /Lo and
Other functions
relay output), Backup, Scaling, Average function
RS-232C, GP-IB standard
Interfaces
100 to 240 V AC, 50/60 Hz, 40 VA max. (at 100 to 120 V AC), 50 VA max.
Power supply
(at 200 to 240 V AC)
marked
•±0.2% high basic accuracy, 0.2sec response speed
•Wide measurement range (1 mA to 50 A), up to 50.000 A direct input
•Wide frequency bandwidth from 1 Hz to 100 kHz
Power Meters
Dimensions and mass 210 mm (8.27 in)W × 100 mm (3.94 in)H × 261 mm (10.28 in)D, 2.7 kg (95.2 oz)
Instruction manual ×1, Power cord ×1, Connector for EXT I/O ×1
Accessories
RS-232C CABLE
9638
GP-IB CONNECTOR
CABLE 9151-02
For the PC, 9pin - 9pin,
For the PC, 9pin - 25pin, 2 m (6.56 ft) length
cross, 1.8m (5.91 ft) length cross, 1.8m (5.91 ft) length
Printer options
PC communication
RS-232C CABLE
9637
AC ADAPTER
For printing numerical 9443-02
PRINTER 9442
values 112 mm (4.41 in) For the Printer 9442,
paper width
EU type
CONNECTION
CABLE 9444
For the Printer 9442,
9 pin - 9 pin,
1.5 m (4.92 ft) length
RECORDING
PAPER 1196
For the Printer 9442,
112 mm (4.41 in) × 25 m
(82.03 ft), 10 rolls/set
High-performance 3-phase power meter makes system construction easy
POWER HiTESTER 3331
Discontinued
■ Basic specifications (Accuracy guaranteed for 6 months)
Single-phase 3-wires, Three-phase 3-wires, Single-phase 2-wires (no independent
Measurement lines settings for each line)
marked
• ±0.2% high basic accuracy, 0.2sec response speed
• Wide measurement range (500 mA to 50 A), up to 50.000 A direct
input
• Wide frequency bandwidth of 10 Hz to 100 kHz
Voltage, Current, Current peak, Active power, Apparent power, Reactive
Measurement items power, Power factor, Phase angle, Frequency, Power integration, Current
integration
[Voltage] 150/ 300/ 600 V AC
[Current] 500 mA, 1/ 2/ 5/ 10/ 20/ 50 A AC
Measurement ranges
[Power] 75.000 W to 60.000 kW (combination of voltage and current ranges)
[Frequency] Auto/ 500 Hz/ 50 kHz (select voltage or current)
Input resistance (50/60 Hz) [Voltage] 2 MΩ, [Current] 2 mΩ or less (direct input)
±0.1 % rdg. ±0.1 % f.s. (45 Hz to 66 Hz)
Basic accuracy
Display refresh rate 5 times/s
Frequency
10 Hz to 100 kHz
characteristics
Data update time: 5 times/s, Measurement range: 0.00000 m to ±999999
Integration
MAh/MWh, (integration time up to 10,000 hours)
measurement
Current I1, I2, I3 (displays max. absolute value, I3 not available during single
Wave peak
phase measurement),
measurement
Effective input range: Six times the current range, or Max. 90 A peak
Number of channel: 1 ch,
Output items: Voltage, Current, Current peak, Active power, Apparent
D/A output
power, Reactive power, Power factor, Phase angle, Frequency, Integration
(each channels value, or sum)
Analog output
Monitor output
Other functions
Interfaces
Power supply
Dimensions and mass
Accessories
RS-232C CABLE
9638
GP-IB CONNECTOR
CABLE 9151-02
For the PC, 9pin - 9pin,
For the PC, 9pin - 25pin, 2 m (6.56 ft) length
cross, 1.8m (5.91 ft) length cross, 1.8m (5.91 ft) length
Printer options
PC communication
62
RS-232C CABLE
9637
Voltage, Current, Power simultaneously, DC ±5 V f.s.
Voltage, Current simultaneously (waveform output), 1 Vrms f.s.
Backup, Scaling, Average function
RS-232C, GP-IB standard
100 to 240 V AC, 50/60 Hz, 50 VA max.
210 mm (8.27 in)W × 100 mm (3.94 in)H × 261 mm (10.28 in)D, 2.5 kg (88.2 oz)
Instruction manual ×1, Power cord ×1, Connector for EXT I/O ×1
AC ADAPTER
For printing numerical 9443-02
PRINTER 9442
values 112 mm (4.41 in) For the Printer 9442,
paper width
EU type
CONNECTION
CABLE 9444
For the Printer 9442,
9 pin - 9 pin,
1.5 m (4.92 ft) length
RECORDING
PAPER 1196
For the Printer 9442,
112 mm (4.41 in) × 25 m
(82.03 ft), 10 rolls/set
Power Meters
DC, or 0.5 Hz to 1 MHz wide bandwidth. Wide spectrum power meter for comprehensive device assessment
POWER HiTESTER 3193-10
marked
Rear side
•A rich assortment of measurement functions including voltage, current,
power, waveform peak value and efficiency
•High-precision with basic accuracy of ±0.2 %, High-speed response of 0.1 s
•Measure up to six circuits simultaneously
•Select from 3 types of input units
Note: Main unit 3193-10 cannot operate alone - please purchase an input unit Model 9600
to 9605 for factory installation prior to shipment. All subsequent input unit replacements or
expansions must be conducted at HIOKI for an additional service charge.
■ Basic specifications (Accuracy guaranteed for 6 months)
Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and threeMeasurement lines
phase 4-wire systems
[Using the optional 9600, 9601, 9602]
Voltage, current, voltage/current peak, active power, reactive power,
apparent power, power factor, phase angle, frequency, current integration,
power integration, load rate, efficiency
Measurement items [Using the optional 9603, added function]
Voltage, torque, rotation, frequency, motor output
[Using the optional 9605, added function]
Harmonic measurement, waveform, voltage fluctuation / flicker measurement function
[Voltage] 6/ 15/ 30/ 60/ 150/ 300/ 600/ 1000 V
[Current] 200/ 500 mA, 1/ 2/ 5/ 10/ 20/ 50 A
Measurement range [Power] 1.2 W to 150 kW
(using the 9600)
(Depends on measurement mode and combination of voltage and current range)
[Frequency] 50/ 500/ 5 k/ 50 k/ 2 MHz
Basic accuracy
±0.1 % rdg. ±0.1 % f.s. (45 Hz to 66 Hz, using the 9600)
(Active power)
Accessories
Instruction manual ×1, Power cord ×1, Connector ×1
* Input modules are factory-installed options, must specify when ordering * Use the same input unit for a particular measurement line.
* When selecting the 9602 Input Unit, be sure to also purchase the appropriate clamp sensor.
HARMONIC/FLICKER
AC/DC DIRECT
AC DIRECT
AC/DC CLAMP
EXTERNAL SIGNAL
PRINTER UNIT MEASUREMENTS UNIT
9605
INPUT UNIT
INPUT UNIT
INPUT UNIT
INPUT UNIT 9603
9604
For the 3193, 3193-10
Data print, screen For the 3193, 3193-10 only,
9600
9601
9602
only, Pulse, DC voltage
copy, built-in unit Harmonic analysis up to 50th
6 V to 1 kV, 200
60 V to 1 kV, 200
6 V to 600 V, 500 mA
order, instant flicker value
input, 2 channels input
type
to 500 A, * Depends
mA to 50 A
mA to 50 A
display or other monitoring, to be
on clamp on sensor in
installed in Model 3193/3193-10
use
Printer option
Factory-installed options
Power Meters
Display refresh rate 8 times /s
[Using the 9600] DC, 0.5 Hz to 1 MHz
Frequency charac[Using the 9601] 5 Hz to 100 kHz
teristics
[Using the 9602] DC, 0.5 Hz to 200 kHz
Waveform peak measurement, Efficiency measurement, D/A output,
External control, Scaling, Averaging, Back up function, PM measurement
Functions
at motor output (using the optional 9603), etc,.
RS-232C, GP-IB standard
Interfaces
100/ 120/ 200/ 230 V AC, switched automatically, 50/60 Hz, 150 VA max.
Power supply
430 mm (16.93 in)W × 150 mm (5.91 in)H × 370 mm (14.57 in)D, 15 kg (529.1 oz)
Dimensions and mass (at options installed)
RECORDING PAPER
9232
For the Printer option 9604,
74 mm (2.91 in) × 10 m
(32.81 ft), 10 rolls/set
Common options for the model 3193-10 and discontinued Models 3193, 3194
* Model CT6863 is recognized as the UNIVERSAL CLAMP ON CT Model 9278 by Model 3193/ 3193-10/ 3194, but operability is supported.
* In order to use AC/DC CURRENT SENSOR Model CT6862 with Model 3193/ 3194, a firmware upgrade of Model 3193/ 3194 is required.
Current measurement
AC/DC CURRENT
SENSOR CT6865
AC/DC CURRENT
SENSOR 9709
AC/DC CURRENT
SENSOR CT6863
CAT III 1000 V, 1000 A
AC/DC rated current, DC to
20 kHz response, φ 36 mm
(1.42 in) core dia., 3 m (9.84
ft) cord length
CAT III 1000 V, 500 A AC/
DC rated current, DC to
100 kHz response, φ 36 mm
(1.42 in) core dia., 3 m (9.84
ft) cord length
CAT III 1000 V, 200 A AC/
DC rated current, DC to
500 kHz response, φ 24 mm
(0.94 in) core dia., 3 m (9.84
ft) cord length
Black/ Red, 3 m (9.84 ft) length,
Alligator clip ×2
MAGNETIC ADAPTER 9804
Attaches to the tip of the Voltage
Cord L9438-50 or other, Red/Black
set (each 1)
PC communication
Voltage measurement
VOLTAGE CORD L9438-50
AC/DC CURRENT
SENSOR CT6862
UNIVERSAL CLAMP
ON CT 9279
CAT III 1000 V, 50 A AC/ 600 Vrms insulated wire, 500
DC rated current, DC to 1
A AC/DC rated current, DC
MHz response, φ 24 mm
to 20 kHz response, φ 40 mm
(0.94 in) core dia., 3 m (9.84 (1.57 in) core dia., 3 m (9.84 ft)
ft) cord length
cord length, Not CE marked
RS-232C CABLE
9637
RS-232C CABLE
9638
UNIVERSAL CLAMP UNIVERSAL CLAMP CLAMP ON SENSOR
ON CT 9278
ON CT 9277
9272-10
CAT II 600 Vrms, CAT III
CAT II 600 Vrms, CAT III CAT III 600 Vrms, 20 A/200 A
300 Vrms, 200 A AC/DC
300 Vrms, 20 A AC/DC
AC rated current, 1 Hz to 100
rated current, DC to 100 kHz rated current, DC to 100 kHz kHz response, φ 46 mm (1.81
response, φ 20 mm (0.79 in)
response, φ 20 mm (0.79 in)
in) core dia., 3 m (9.84 ft) cord
core dia., 3 m (9.84 ft) cord
core dia., 3 m (9.84 ft) cord
length
length
length
GP-IB CONNECTOR
CABLE 9151-02
For the PC, 9pin - 9pin,
For the PC, 9pin - 25pin, 2 m (6.56 ft) length
cross, 1.8m (5.91 ft) length cross, 1.8m (5.91 ft) length
Comprehensive measurement of motor power, rpm, torque, converter efficiency, and harmonics with a single instrument (Model 3193-10)
Example of Assessment Trial of EV ( Electric Vehicle)
Comprehensive analysis of motor power or converter efficiency
• Separate charge/generation integration
capability.
• Measurement under live circuit conditions.
(Clamp input)
•
•
3ch : Voltage, Current, Active power
Separate charge / generation integration ±Wh
1, 2 ch :
After inverted DC to AC three phase Voltage,
Current, Active power, integration (Wh)
Using the 9603 External signal input unit, the analog output of a torque sensor is directly connected
to chA. By inputting the output of a tachometer (analog signal or pulse signal) to chB, a system for
measuring torque, rotation count and motor power can be obtained.
63
AC/DC Current Probes
Wide-band current probe allows direct input to oscilloscope
CLAMP ON PROBE 3273-50, 3274, 3275, 3276
■ Frequency response (Characteristics Example)
Insulated
conductor
3275
Amplitude [dB, 0dB=1V]
marked
3273-50 : DC to 50 MHz (-3 dB)
Amplitude [dB, 0dB=1V]
3276: DC to 100 MHz (-3 dB)
CAT III 300 V
CAT II 600 V
Frequency [Hz]
Frequency [Hz]
3272
3273-50
CAT I 300 V
3276
CAT I 300 V
3269
•Highly accurate observation across a wide band from DC to MHz
•Newly developed indium-antimony (InSb) thin-film Hall element
•Connects directly to oscilloscope or Memory HiCorder BNC input terminal
•High S/N characteristics enable the measurement of ultra low mA order current waveforms (3273-50, 3276)
DC to 50 MHz, 30 A
DC to 10 MHz, 150 A
DC to 2 MHz, 500 A
DC to 100 MHz, 30 A
Model 3273-50
Model 3274
Model 3275
Model 3276
Amplitude [dB, 0dB=1V]
3274
CAT III 300 V
CAT II 600 V
3275: DC to 2 MHz (-3 dB)
Amplitude [dB, 0dB=1V]
3274: DC to 10 MHz (-3 dB)
Frequency [Hz]
Frequency [Hz]
Power supply plug pin assignment * Connector type: LEMO inc./ FFA.0S.304.CLAC42Z
(Plug as seen from the front)
1
2
4
3
1 : Not connected
2 : GND
3 : V- (-12V)
4 : V+ (+12V)
Connects to the FET probe power supply outlet of an
oscilloscope, or to the optional 3269 / 3272 power
supply unit.
Use the Power Supply 3269/3272 for general measurements or when power is not available
from the Memory Hicorder or oscilloscope. When performing continuous measurements, be
aware of offset voltage drift.
Current Probes
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
3276
3273-50
3274
3275
DC to 100 MHz (-3 dB)
DC to 50 MHz (-3 dB)
DC to 10 MHz (-3 dB)
DC to 2 MHz (-3 dB)
Frequency bandwidth
3.5 ns or shorter
7 ns or shorter
35 ns or shorter
175 ns or shorter
Rise time
2.5 mA rms max. (bandwidth limited to 20 MHz)
25 mA rms max. (bandwidth limited to 20 MHz)
Noise level
Continuous allowable input
30 A rms
150 A rms
500 A rms
Frequency Derating
Y axis: Max. input current
(Arms)
X axis: Frequency (Hz)
Max. allowable
peak input
Amplitude accuracy
(30 min. after power-on, after
degaussing and zero-adjustment)
Output rate
Max. rated voltage to earth
Core diameter
Power supply
Dimensions and
mass
Accessories
50 A peak (non continuous)
300 A peak (non continuous)
500 A peak (pulse width: 30 μs or shorter)
700 A peak (non continuous)
±1.0 % rdg. ±1 mV f.s. (DC, 45 to 66 Hz, 0 to 30 A rms)
±2 % rdg. (DC, 45 to 66 Hz, 30 A rms to 50 A peak)
±1.0 % rdg. ±1 mV f.s. (DC, 45 to 66 Hz, 0 to 150 A rms)
±2.0 % rdg. (DC, 45 to 66 Hz, 150 A to 300 A peak)
±1.0 % rdg. ±5 mV f.s. (DC, 45 to 66 Hz, 0 to 500 A rms)
±2.0 % rdg. (DC, 45 to 66 Hz, 500 A to 700 A peak)
0.1 V/A *Device output is terminated internally. Use with a device having a 1 MΩ input resistance or higher.
0.01 V/A *Device output is terminated internally. Use with a device having a 1 MΩ input resistance or higher.
300 V CAT I (insulated wire)
600 V CAT II, 300 V CAT III (insulated wire)
φ 5 mm (0.20 in)
φ 20 mm (0.79 in)
±12 V ±0.5 V, 5.3 VA max.
±12 V ±0.5 V, 5.6 VA max.
±12 V ±0.5 V, 5.5 VA max.
±12 V ±0.5 V, 7.2 VA max.
175 mm (6.89 in)W × 18 mm (0.71 in)H × 40 mm 175 mm (6.89 in)W × 18 mm (0.71 in)H × 40 mm 176 mm (6.93 in)W × 69 mm (2.72 in)H × 27 mm 176 mm (6.93 in)W × 69 mm (2.72 in)H × 27 mm
(1.57 in)D, 240 g (8.5 oz)
(1.57 in)D, 230 g (8.1 oz)
(1.06 in)D, 500 g (17.6 oz)
(1.06 in)D, 520 g (18.3 oz)
Sensor cable BNC terminal: 1.5 m (4.92 ft) (3273-50, 3276), 2 m (6.56 ft) (3274, 3275), Power cable: 1 m (3.28 ft), Power plug: FFA.0S.304.CLAC42Z / LEMO inc.
Instruction manual ×1, Carrying case × 1
Instruction manual ×1, Soft case × 1
Instruction manual ×1, Carrying case × 1
■ Option for 3273-50 (To connect Memory HiCorder)
CONVERSION CABLE 9319
(To connect the 3273-50 and the F/V UNIT 8940)
Power supply for clamp-on probes
POWER SUPPLY 3269, 3272
marked
Combination example of the
3272 + Clamp-on probe
■ Basic specifications (Accuracy guaranteed for 1 year)
3269
3272
Model 3273-50, 3274, 3275 or 3276 Model 3273-50, 3274, 3275 or 3276 × 1
unit. (One sensor only)
Compatible sen- × 4 units
* May be used with up to 2 units of Model 3273 (not -50 type),
sors
Note: Also up to 4 units for the discontinued
and up to 2 units of Models 3273-50, 3274, 3275 or 3276 on
Model 3273
Power supply
Dimensions and
mass
Accessories
3269
• Power supply for the CLAMP ON PROBE 3273-50/3274/3275/3276
• Supplies power when connected to a general-purpose instrument
such as a recorder.
64
condition that the measurement current is sufficiently low.
100 V to 240 V AC (free) 50/60 Hz
170 VA max.
80 mm (3.15 in)W × 119 mm (4.69 in)H ×
200 mm (7.87 in)D, 1.1 kg (38.8 oz)
100 V or 120/ 220/ 240 V AC (specify when
ordering), 50/60 Hz 20 VA max.
73 mm (2.87 in)W × 110 mm (4.33 in)H × 186
mm (7.32 in)D, 1.1 kg (38.8 oz)
Power cord ×1, Instruction manual ×1,
Instruction manual ×1, Power cord ×1
Spare fuse ×1
These products cannot be used alone. To measure current, a compatible current sensor
is required.
Current Sensors/CT Sensors
AC/DC Clamp Sensors to Meet New DC Measurement Needs
CLAMP ON AC/DC SENSOR CT9691/9692/9693 series
CAT III 600 V
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
CT9691
100 A AC/DC
Continuous 100 Arms
DC to 10 kHz (-3dB)
Rated input current
Max. allowable input
Bandwidth
Max. rated voltage to earth
CT9692
Power consumption
Core diameter
CT9693
Cord length
Accessories
CT6590
• Ideal for solar power generation systems, UPS and battery testing
• Large current measuring applications in the fields of EV and HEV
hybrid electric vehicles (CT9693)
• Wide-bandwidth DC to 10 kHz (CT9691), 20 kHz (CT9692) excellent
frequency characteristics
• Applications in solar power generation, battery charge and discharge,
and measuring the secondary side of inverters
• For observing waveforms in combination with oscilloscopes or Hioki
Memory HiCorders (use with the CT6590)
DC to 20 kHz, 200 A
DC to 10 kHz, 100 A
CT9691-90 (CT6590 bundled with CT9691)
CT9691 (Clamp on AC/DC Sensor only)
DC to 15 kHz, 2000 A
CT9692-90 (CT6590 bundled with CT9692)
CT9692 (Clamp on AC/DC Sensor only)
Power supply for the sensor
CT6590 (Bundled with the CT969x-90)
2 m (6.56 ft)
Instruction manual ×1
■ CT6590 Basic specifications (Power supply for sensor, Accuracy guaranteed for 1 year)
CT9691, 9691
CT9692, 9692
CT9693, 9693
Compatible sensor
(Discontinued model 9691: Phase (Discontinued model 9692: Phase (Discontinued model 9693: Phase
models
not defined)
not defined)
not defined)
Output
Output (in combination with a sensor)
Selectable H range/ L range, BNC terminal
100 mV f.s./100 A range
200 mV f.s./200 A range
100 mV f.s./10 A range
200 mV f.s./20 A range
Amplitude basic
accuracy (in combi-
200 mV f.s./2000 A range
200 mV f.s./200 A range
±1.5 % rdg. ±1.0 % f.s.
±1.5 % rdg. ±0.5 % f.s.
±1.5 % rdg. ±0.5 % f.s.
Phase basic
accuracy (in combi- ±2 deg. (DC < f ≤ 66 Hz)
±2 deg. (DC < f ≤ 66 Hz)
±2 deg. (45 ≤ f ≤ 66 Hz)
(DC ≤ f ≤ 66 Hz)
nation with a sensor)
(DC ≤ f ≤ 66 Hz)
(45 ≤ f ≤ 66 Hz)
nation with a sensor)
Power supply
Dimensions and
mass
Accessories
LR6 (AA) alkaline batteries ×2, Continuous use : 25 hr (Rated Power 1 VA), or
AC adapter 9445-02/-03 (Rated Power 1.5 VA), or External power supply 5 to
15 V DC (Rated Power 1.5 VA)
36 mm (1.42 in)W × 120 mm (4.72 in)H × 34 mm (1.34 in)D, 165 g (5.8 oz)
(including batteries), cord length 1 m (3.28 ft)
LR6 (AA) alkaline batteries ×2, Instruction manual ×1, Connector cover ×1
Options
Note: To use the CT9691/ CT9692/ CT9693 sensor with the Hioki PW3198 Power Quality Analyzer or
the Hioki Memory HiCorder series, it must be connected and powered via the Sensor Unit CT6590
Note: The CT9691/ CT9692/ CT9693 sensor may also be used with the Clamp on AC/DC HiTester 3290/
3290-10 (without the Sensor Unit CT6590)
AC ADAPTER
9445-02
AC ADAPTER
9445-03
For USA, 9V/ 1A
For EU, 9V/ 1A
Current Sensors
CT9693-90 (CT6590 bundled with CT9693)
CT9693 (Clamp on AC/DC Sensor only)
CT9693
2000 A AC/DC
Continuous 2000 Arms
DC to 15 kHz (-3dB)
φ 35 mm (1.38 in)
φ 55 mm (2.17 in)
53 mm (2.09 in)W × 129 mm 62 mm (2.44 in)W × 167 mm 62 mm (2.44 in)W × 196 mm
(5.08 in)H × 18 mm (0.71 in)D, (6.57 in)H × 35 mm (1.38 in)D, (7.72 in)H × 35 mm (1.38 in)D,
230 g (8.1 oz)
410 g (14.5 oz)
500 g (17.6 oz)
Dimensions and
mass
CT9691
CT9692
200 A AC/DC
Continuous 200 Arms
DC to 20 kHz (-3dB)
600 V AC/DC CAT III
50 mVA
φ 33 mm (1.30 in)
Wide-bandwidth DC to 100kHz (9279: to 20kHz) High-precision sensors to view waveforms (for AC/DC)
UNIVERSAL CLAMP ON CT 9277/9278/9279
■ Basic specifications (Accuracy guaranteed for 1 year)
9277
9278
9279
20 A AC/DC
200 A AC/DC
500 A AC/DC
Rated current
Continuous allowable input
50 A rms
350 A rms
650 A rms
Amplitude accuracy ±0.5 % rdg. ±0.05 % f.s. (DC and 45 to 66 Hz, 30 min or more warming-up after degaussing)
±0.2° (45 to 66 Hz, 30 min or more warming-up after degaussing)
Phase accuracy
Frequency characteristics
DC to 1 kHz: ±1.0 % (±0.5°)
1 k to 50 kHz: ±2.5 % (±2.5°)
50 k to 100 kHz: ±5.0 % (±5.0°)
(Amplitude/Phase, deviation
from accuracy)
Output rate
Insulated Wire
9279
Not CE Marked
(Via the 9555-10)
Max. rated voltage to earth
9278
CAT III 300 V
CAT II 600 V
Core diameter
Supply consumption
Power supply
9277
CAT III 300 V
CAT II 600 V
•Low zero drift allows stable, long-term measurement
Dimensions and
mass
DC to 100 kHz, 20 A
DC to 100 kHz, 200 A
DC to 20 kHz, 500 A
Model 9277
Model 9278
Model 9279
2 V/Rated current
(voltage output with the Sensor Unit 9555-10, use with a device having a 1 MΩ input resistance or higher)
600 V CAT II, 300 V CAT III
600 Vrms AC (850 V peak, insulated wire)
φ 20 mm (0.79 in)
φ 40 mm (1.57 in)
3.6 W (with rated input) 7.2 W (with rated input)
7.2 W (with rated input)
±12 V to ±15 V (Power suppled via the 9555-10, 9555-10 requirement with 100 to 240 V AC)
176 mm (6.93 in)W × 69 mm (2.72 in)H × 27 mm (1.06 in)D,
470 g (16.6 oz), cord length: 3 m(9.84 ft)
Accessories
Options
These products cannot be used alone. The optional 9555-10 is required in order to supply power
and connect the clamp to a Memory HiCorder or other instrument. Products can be directly
connected the Power Meter 3193, 3193-10, 3194, and 3390 (cannot use with the 3390-10).
marked
220 mm (8.66 in)W × 103 mm (4.06 in)
H × 43.5 mm (1.71 in)D, 470 g (16.6 oz),
cord length: 3 m(9.84 ft)
Carrying case 9375 ×1, Instruction manual ×1, Mark-band ×6
CONNECTION CORD CONVERSION CABLE
CONNECTION
9165
9318
CORD L9217
SENSOR UNIT 9555-10 Cord has insulated BNC Cord has metallic BNC con- The 9270 to 9272s, 9277
Power supply for the
Current Sensor, used alone
SENSOR UNIT 9555-10
DC to 1 kHz: ±1.0 % (±0.5°)
1 k to 10 kHz: ±2.5 % (±2.5°)
10 k to 20 kHz: ±5.0 % (±5.0°)
connectors at both ends,
signal output use, 1.6 m
(5.25 ft) length
nectors at both ends, use at
to 9279s connects to the
metallic terminal, 1.5 m (4.92 8971/40/51, 38 cm (14.96
ft) length, Not CE marked
inch) length
■ Basic specifications
One of the CT6865 to CT6862s, 9709, 9279 to 9277s, 9272-10, 9272 to
Compatible sensor
9270 series
BNC Terminal
Output Terminal
AC Adapter 9418-15, 100 to 240 V, 50/60 Hz, 20 VA
Power supply
Dimensions and mass 42 mm (1.65 in)W × 82 mm (3.27 in)H × 132 mm (5.20 in)D, 600 g (21.2 oz)
Instruction manual ×1, AC Adapter 9418-15 ×1
Accessories
•Power supply for the Current sensor series when the sensors are used alone
65
Current Sensors/CT Sensors
Wide-Bandwidth, High-Precision and Large Current Measurement Possible
AC/DC CURRENT SENSOR CT6865, 9709
■ Basic specifications
guaranteed for 6 months, 10
CT6865 (Accuracy guaranteed for 1 year) 9709 (accuracy
minutes of warm-up time)
1000 A AC/DC
500 A AC/DC
1200 A AC/DC
700 Arms
Rated input current
CAT III 1000 V
Max. allowable input (Continuous 1800 A peak, up to 100 Hz, up to 40 °C (104 °F), (1000 Apeak, requires derating at frequency)
other requires derating characteristics)
• 1000A large current measuring applications in the fields of EV and HEV (hybrid
electric vehicles)(CT6865)
• Unparalleled characteristics in a 1000 A class sensor
• Operating temperature range of -30°C to 85°C (CT6865)
• Super high precision, ±0.06% amplitude accuracy, ±0.2 degree phase accuracy
• Wide-bandwidth DC to 20 kHz (CT6865), 100 kHz (9709) excellent frequency characteristics
• Ideal for evaluation of solar power generation and fuel cells to measure battery
charge and discharge and the secondary side of inverters
• For observing waveforms to be used with the oscilloscopes or Memory HiCorders
(use with the 9555-10)
Frequency characteristics
Amplitude: DC to 20 kHz
Phase: DC to 1 kHz
Amplitude: DC to 100 kHz
Phase: DC to 100 kHz
Amplitude and
Phase accuracy
DC ±0.05 % rdg. ±0.01 % f.s.
(Phase: Not defined)
16 Hz ≤ f ≤ 66 Hz ±0.05 % rdg. ±0.01 %
f.s., Phase: ±0.2 deg.
Amplitude is defined to 20 kHz, Phase is
defined to 1 kHz
DC, 45 Hz ≤ f ≤ 66 Hz
(±0.05 % rdg. ±0.01 % f.s. (Phase: ±0.2 deg)
Defined to 100 kHz
Power consumption
having a 1 MΩ input resistance or higher)
Max. rated voltage to earth
AC/DC 1000 V (50/60 Hz, CAT III )
φ 36 mm (1.42 in)
Core diameter
-30°C to +85°C (-22°F to 185°F)
0°C to +50°C (32°F to 122°F)
Operating tempera80% rh or less (with no condensation) 80% rh or less (with no condensation)
ture, humidity
DC ±11 V to ±15 V (Power suppled via the 9555-10, 9555-10 supports 100 to 240 V AC)
Power supply
Dimensions and 160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97
in)D, 980 g (34.6 oz), cord length 3 m (9.84 ft)
in)D, 850 g (30.0 oz), cord length: 3 m (9.84 ft)
mass
Instruction manual ×1, Mark bands ×6
Accessories
Options for the 9709, 9272-10
Options
Current Sensors
connectors at both ends,
signal output use, 1.6 m
(5.25 ft) length
5 VA max.
(at 500 A/55 Hz, ±12 V power requirement)
2 V /rated current value (voltage output with the Sensor Unit 9555-10, use with a device
Output voltage rate
CONNECTION CORD CONVERSION CABLE
CONNECTION
9165
9318
CORD L9217
SENSOR UNIT 9555-10 Cord has insulated BNC Cord has metallic BNC con- The 9270 to 9272s, 9277
Power supply for the
Current Sensor, used alone
7 VA max.
(at 1000 A/55 Hz, ±12 V power requirement)
to 9279s connects to the
nectors at both ends, use at
metallic terminal, 1.5 m (4.92 8971/40/51, 38 cm (14.96
ft) length, Not CE marked
inch) length
*The Clamp Sensor 9272-10 has
different output wiring than the
previous 9272. Both the 9318 and
9705 are required in order to
connect to the F/V Unit 8940.
CONVERSION CABLE 9705
EXTENSION CABLE 9706
To connect Current Sensor to the 8940, 0.2 m
(7.87 inch) length
Caution! Cannot be used in combination with
the CT6862
Extension for 5 m (16.41 ft) length, connect up to 2 cables in series.
Caution! Cannot be used in combination
with the CT6862/ 6863 or 9277 to 9279
Delivering Wide-bandwidth and High-precision Current Measurement
AC/DC CURRENT SENSOR CT6862, CT6863
■ Basic specifications (Accuracy guaranteed for 1 year)
CT6862
CT6863
50 A AC/DC
200 A AC/DC
Rated current
Max. allowable
100 A continuous (requires derating at 400 A continuous (requires derating at
frequency or temperature)
frequency or temperature)
input
Amplitude: DC to 500 kHz
Frequency char- Amplitude: DC to 1 MHz
Phase: DC to 300 kHz
Phase: DC to 300 kHz
acteristics
CAT III 1000 V
Amplitude and
Phase accuracy
DC ±0.05 % rdg. ±0.01 % f.s. (Phase: Not
defined)
16 Hz ≤ f ≤ 400 Hz ±0.05 % rdg. ±0.01 % f.s.
(Phase: ±0.2 deg)
Defined to 1 MHz
DC ±0.05 % rdg. ±0.01 % f.s. (Phase: Not
defined)
16 Hz ≤ f ≤ 400 Hz ±0.05 % rdg. ±0.01 % f.s.
(Phase: ±0.2 deg)
Defined to 500 kHz
Power consumption 5 VA max. (at 50 A/55 Hz, ±12 V power requirement) 6 VA max. (at 200 A/55 Hz, ±12 V power requirement)
2 V/rated current range (voltage output with the Sensor Unit 9555-10, use with a device
Output voltage
having a 1 MΩ input resistance or higher)
• Super high precision, ±0.06% amplitude accuracy, ±0.2 degree phase accuracy
• Wide-bandwidth DC to 1 MHz (CT6862) excellent frequency characteristics
• Applications in the fields of electric and hybrid electric vehicles
• Wide operating temperature range fit for automobile applications
•Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
•For observing waveforms with Memory HiCorders
Max. rated voltage to earth AC/DC 1000 V (50/60 Hz, CAT III )
φ 24 mm (0.94 in)
Operating tempera-30°C to +85°C (-22°F to 185°F), 80% rh or less (with no condensation)
ture, humidity
Core diameter
Power supply
Dimensions and
mass
Accessories
DC ±11 V to ±15 V (Power suppled via the 9555-10, 9555-10 supports 100 to 240 V AC)
70 mm (2.76 in)W × 100 mm (3.94 in)H × 53 mm (2.09 70 mm (2.76 in)W × 100 mm (3.94 in)H × 53 mm (2.09
in)D, cord length: 3 m (9.84 ft), 340 g (12.0 oz)
in)D, cord length: 3 m (9.84 ft), 350 g (12.3 oz)
Instruction manual ×1, Mark bands ×6
Options
CONNECTION CORD CONVERSION CABLE
CONNECTION
9165
9318
CORD L9217
SENSOR UNIT 9555-10 Cord has insulated BNC Cord has metallic BNC con- The 9270 to 9272s, 9277
Power supply for the
Current Sensor, used alone
connectors at both ends,
signal output use, 1.6 m
(5.25 ft) length
nectors at both ends, use at
to 9279s connects to the
metallic terminal, 1.5 m (4.92 8971/40/51, 38 cm (14.96
ft) length, Not CE marked
inch) length
Model CT6865, 9709, CT6862, CT6863 Compatibility
Compatible models
CT6865 Combination status
9709 Combination status
CT6862 Combination status
CT6863 Combination status
s Recognized as 500A rated sensor; set CT ratio to 2
s Recognized as 500A rated sensor; set CT ratio to 2, also
need Conversion Cable 9318.
Maximum number of connectable sensors when using the
MR8847 series or Model 8847: 7
OK
OK
OK
OK
OK
OK
Input unit Model
9602 for the 319310/3193/3194
s Recognized as Model 9279 (500A rated sensor); set CT
ratio to 2
OK
In combination, recognized as
the 9279
OK
In the latest version, the CT ratio [2.5]
is automatically set
OK
In combination, recognized as the 9278
Model 8940
for Memory
HiCorders
s Recognized as 500A rated sensor; set CT ratio to 2, also
need Conversion Cable 9705 and 9318.
Maximum number of connectable sensors when using the
8860 Series: 8; with the 8835-01: 4
s Requires Conversion Cable
9705 and Conversion Cable
9318, used as a substitute for the
9279
5
Model 3390
Model 8971 for the
MR8847-01s
66
s Requires Conversion Cable 9705
and Conversion Cable 9318, used as a
substitute for the 9278
AC Current Sensors
Ideal for measuring current with low frequencies such as inverter control devices
CLAMP ON SENSOR 9272-10
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
20 A AC, or 200 A AC (selectable)
Rated current
Max. allowable input 20 A range: 50 A rms Max. 200 A range: 300 A rms Max.
Amplitude: ±0.3 % rdg. ±0.01 % f.s. Phase: ±0.2 ° (45 to 66 Hz)
Accuracy
Frequency characteristics 1 Hz (±2 % rdg. ±0.1 % f.s.) to 100 kHz (±30 % rdg. ±0.1 % f.s.)
2 V/20 A rated current range, or 2 V/200 A rated current range (voltage output
Output rate
CAT III 600 V
with the Sensor Unit 9555-10, use with a device having a 1 MΩ input resistance or higher)
With the 9555-10
Max. rated voltage to earth 600 V rms (CAT III)
Core diameter
Power supply
Power consumption
Dimensions and mass
Accessories
•Superior low frequency and phase characteristics suitable for testing
the current and power of inverter control devices
•Wide 1 Hz to 100 kHz frequency bandwidth perfect for harmonic analysis, FFT analysis and waveform monitoring
φ 46 mm (1.81 in)
±11 V to ±15 V (Power suppled via the 9555-10, 9555-10 supports 100 to 240 V AC)
5 VA Max. (when measuring 200 A)
78 mm (3.07 in)W × 188 mm (7.40 in)H × 35 mm (1.38 in)D, 430 g (15.2 oz), cord length: 3 m (9.84 ft)
Carrying case 9355 ×1, Instruction manual ×1, Mark bands ×6
Model 9272-10 Compatibility (use with the connection cord)
Compatible models
3193-10, 3193, 3194 (use with the 9602)
This product cannot be used alone. The optional 9555-10 is required in order to supply power
and connect the clamp to a Memory HiCorder or other instrument. The clamp can be directly
connected the Power Meter 3193-10, 3193, 3194, and 3390.
MR8847-01s (use with the 8971)
Model 8940
for Memory HiCorders
Options
CONNECTION CORD CONVERSION CABLE
CONNECTION
9165
9318
CORD L9217
SENSOR UNIT 9555-10 Cord has insulated BNC Cord has metallic BNC con- The 9270 to 9272s, 9277
Power supply for the
Current Sensor, used alone
connectors at both ends,
signal output use, 1.6 m
(5.25 ft) length
nectors at both ends, use at
to 9279s connects to the
metallic terminal, 1.5 m (4.92 8971/40/51, 38 cm (14.96
ft) length, Not CE marked
inch) length
CARRYING CASE 9355
For the 9272-10, 9270s, or other
models
Note
OK
OK
Directly connectable, Add 0.1% rdg. to accuracy
OK
Options for the 9709, 9272-10
*The 9355 is bundled
Status
To connect via the Conversion Cable 9318
Need the Conversion Cable 9705, and use with the Conversion Cable
9318 to connect Model 9272-10 to the F/V Unit 8940. (Not necessary
when using Model 9272 due to different output wiring specifications.)
*The Clamp Sensor 9272-10 has
different output wiring than the
previous 9272. Both the 9318 and
9705 are required in order to
connect to the F/V Unit 8940.
CONVERSION CABLE 9705
EXTENSION CABLE 9706
To connect Current Sensor to the 8940, 0.2 m
(7.87 inch) length
Caution! Cannot be used in combination with
the CT6862
Extension for 5 m (16.41 ft) length, connect up to 2 cables in series.
Caution! Cannot be used in combination
with the CT6862/ 6863 or 9277 to 9279
Current Probes
Simply connect to a tester or recorder to easily measure large currents
CLAMP ON PROBE 9132-50, 9010-50
CAT III 600 V
9132-50
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
9132-50
9010-50
20 A to 1000 A AC, 6 ranges
10 A to 500 A AC, 6 ranges
Rated current
±3 % rdg. ±0.2 % f.s. (45 to 66 Hz)
±2 % rdg. ±1 % f.s. (45 to 66 Hz)
Accuracy
Add to amplitude accuracy for frequencies from
Frequency character- Add to amplitude accuracy for frequencies
40 to 1 kHz: ± 6 % rdg. (at 10 A and 20 A range)
istics
from 40 to 1 kHz: ± 1 % rdg.
± 3 % rdg. (for 50 A range and above)
0.2 V AC f.s. (f.s. = setting rage)
Output rate
(Connect to a voltage input device providing a high input impedance of 1 MΩ)
1000 A rms continuous (all ranges)
Max. allowable input (For 40 Hz to 500 Hz: 100 %, and for 500
9010-50
Hz to 1 kHz: within 90 % of derating)
•Economical clamp sensors for waveform recording with Memory
HiCorders
•Choose from up to six general-purpose ranges
150 A rms continuous (10/20/50 A ranges)
400 A rms continuous (100/200 A ranges)
650 A rms continuous (500 A range)
(For 40 Hz to 100 Hz: 100 %, and for 100 Hz to 1
kHz: within 50 % of derating)
Max. rated voltage to earth 600 Vrms (50/60 Hz, CAT III)
φ55 mm (2.17 in), or 20 mm (0.79 in) ×
φ46 mm (1.81 in)
Core diameter
80 mm (3.15 in) busbar
100 mm (3.94 in)W × 224 mm (8.82 in) 78 mm (3.07 in)W × 188 mm (7.40 in)H ×
Dimensions and mass H × 35 mm (1.38 in)D, 600 g (21.2 oz), 35 mm (1.38 in)D, 420 g (14.8 oz), cord
cord length: 3 m (9.84 ft)
length: 3 m (9.84 ft)
Accessories
Instruction manual ×1
Instruction manual ×1
Options
For commercial power lines, 50/60 Hz (separate power supply not required)
CONVERSION ADAPTER 9704
Receiving end: Female BNC; Output end:
Male banana-plug *Not compatible with
older generation Memory Hicorders with
banana input terminals
Superior phase characteristics let you record waveforms accurately
CLAMP ON PROBE 9018-50
CAT III 600 V
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
10 A to 500 A AC, 6 ranges
Rated current
±1.5 % rdg. ±0.1 % f.s. (45 to 66 Hz)
Accuracy
Frequency charac- Add to amplitude accuracy : ± 1 % rdg.
Add to phase accuracy : ± 2.5 ° for frequencies from 40 Hz to 3 kHz
teristics
Output rate
0.2 V AC f.s. (f.s. = setting rage)
Max. allowable
input
150 A rms continuous (10/20/50 A ranges)
400 A rms continuous (100/200 A ranges)
650 A rms continuous (500 A range)
(Connect to a voltage input device providing a high input impedance of 1 MΩ)
(For 40 Hz to 100 Hz: 100 %, and for 100 Hz to 1 kHz: within 50 % of derating)
Max. rated voltage to earth 600 Vrms (50/60 Hz, CAT III)
•Choose from up to six general-purpose ranges
•Accurately record and analyze waveforms and harmonic signals
φ46 mm (1.81 in)
78 mm (3.07 in)W × 188 mm (7.40 in)H × 35 mm (1.38 in)D, 420 g (14.8 oz),
cord length: 3 m (9.84 ft)
Instruction manual ×1
Options
For commercial power lines, 50/60 Hz (separate power supply not required)
Core diameter
Dimensions and
mass
Accessories
CONVERSION ADAPTER 9704
Receiving end: Female BNC; Output end:
Male banana-plug *Not compatible with
older generation Memory Hicorders with
banana input terminals
67
AC Current Sensors
Sensors for master to branch circuits
Voltage output type for use with load currents:
for the PW3360 series, PW3198, 3197, 3169 series, and 8800 series/MR8800 series
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times, no opening and closing count defined for the 9667 sensor)
Model
9694
9660
9661
9669
CT9667
254 mm
(10.0 in)
CAT III 300V
Primary current rating
CAT III 300V
5 A AC
CAT III 600V
100 A AC
CAT III 1000V
CAT IV 600V
CAT III 600V
500 A AC
1000 A AC
50 A rms (45 Continuous 130 A rms
Max. allowable input Continuous
to 66 Hz)
(45 to 66 Hz)
AC 10 mV/ A
AC 1 mV/ A
Output voltage
Continuous 550 A rms (45 to 66 Hz)
Continuous 1000 A rms (45 to 66 Hz)
AC 1 mV/ A
AC 0.5 mV/ A
Amplitude Accuracy
±0.3 % rdg. ±0.01 % f.s. (45 to 66 Hz)
±1.0 % rdg. ±0.01 % f.s. (45 to 66 Hz)
±0.3 % rdg. ±0.02 % f.s. (45 to 66 Hz)
Phase Accuracy
±2° (45 Hz to 5 kHz)
Frequency characteristics
Max. rated voltage to earth
±0.5° (45 Hz to 5 kHz)
Less than 300 Vrms
Power supply
φ 46 mm (1.81 in)
Not required
±1° (45 Hz to 5 kHz)
±1° (45 to 66 Hz)
40 Hz to 5 kHz: ±2.0 % (deviation from accuracy)
10 Hz to 20 kHz (±3dB)
Less than 1000 Vrms (CAT III), 600V rms (CAT IV)
φ 55 mm (2.17 in) or
80 mm (3.15 in) × 20 mm (0.79 in) bus-bar
φ 254 mm (10.0 inch)
Not required
LR6 (AA) alkaline batteries ×2, Continuous use :
7 days, or AC adapter 9445-02/-03, or External
power supply 5 to 15 VDC
Not required
78 mm (3.07 in)W × 152 mm (5.98 in)H × 42 99.5 mm (3.92 in)W × 188 mm (7.40 in)H × 42 Sensor thickness: φ 13 mm, Cable length: Between sensor and battery box: 2 m (6.56 ft), Output cable: 1 m
mm (1.65 in)D, 380 g (13.4 oz)
mm (1.65 in)D, 590 g (20.8 oz)
(3.28 ft), Battery box: 35 mm (1.38 in)W × 120.5 mm
(4.74 in)H × 34 mm (1.34 in)D, 470 g (16.6 oz)
Cord length 3 m (9.84 ft), Output terminal: BNC
46 mm (1.81 in)W × 135 mm (5.31 in)H × 21 mm
(0.83 in)D, 230 g (8.1 oz)
f.s. is the sensorʼs rated primary current value.
Current Probes
For load current levels: Voltage output
For leak current: Voltage output
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
Model
9695-02
9695-03
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
Model
9675
9657-10
Branch circuit ZCT
Primary current rating
Max. allowable input
Output voltage
Amplitude Accuracy
Phase Accuracy
Frequency characteristics
Max. rated voltage to earth
Core diameter
Power supply
Dimensions and mass
Insulated
conductor
Insulated
conductor
CAT III 300V
For 3169-20s (Requires the 9219)
CAT III 300V
For 3169-20s (Requires the 9219)
50 A AC
100 A AC
Continuous 60 Arms (45 to 66 Hz) Continuous 130 Arms (45 to 66 Hz)
AC 10 mV/ A
AC 1 mV/ A
±0.3 % rdg. ±0.02 % f.s. (45 to 66 Hz)
±2° (45 to 5 kHz)
±1° (45 to 5 kHz)
40 Hz to 5 kHz: ±1.0 % (Amplitude deviation from accuracy)
Less than 300 Vrms (Insulated conductor)
φ 15 mm (0.59 in)
Not required
50.5 mm (1.99 in)W × 58 mm (2.28 in)H × 18.7 mm (0.74 in)D, 50 g (1.8 oz)
Output terminal : M3 terminal (outside 3 mm, 0.12 inch diameter)
Option: Connection cable 9219 (3 m, 9.84 ft length)
f.s. is the sensorʼs rated primary current value.
l 9695 OPTION
CONNECTION CABLE 9219
General-purpose ZCT
Insulated
conductor
CAT III 300V
For load current levels: Current output
For the 8205-10, 8206-10 (Recorder)
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
Model
9650
9651
CAT III 300V
Primary current rating
Max. allowable input
Secondary current rating
Amplitude Accuracy
Phase Accuracy
CAT III 600V
100 A AC
Continuous 130 Arms (45 to 66 Hz)
100 mA AC
±1.5 % rdg. ±0.03 % f.s. (50/60 Hz)
Frequency characteristics
40 Hz to 1 kHz: ±8 %
(Amplitude deviation from accuracy)
(Amplitude deviation from accuracy)
Max. rated voltage to earth
Less than 300 Vrms
Less than 600 Vrms
46 mm (1.81 in)W × 135 mm (5.31 in)H × 21 mm
(0.83 in)D, 200 g (7.1 oz), cord length: 3 m (9.84 ft),
exclusive use 2-pin terminal
68
9668
CAT III 600V
500 A AC
Continuous 600 Arms (45 to 66 Hz)
500 mA AC
±1.5 % rdg. ±0.03 % f.s. (50/60 Hz)
Not defined (cannot be used with power meters)
40 Hz to 1 kHz: ±3 %
φ 15 mm (0.59 in)
Insulated
conductor
CAT III 300V
10 A AC (Leak current, 50/60 Hz)
Primary current rating
Continuous 10 Arms (45 to 66 Hz)
Continuous 30 Arms (45 to 66 Hz)
Max. allowable input
AC 100 mV/ A
Output voltage
±1.0 % rdg. ±0.005% f.s. (45 to 66 Hz)
±1.0 % rdg. ±0.05% f.s. (45 to 66 Hz)
Amplitude Accuracy
±5° (50 or 60 Hz)
±3° (50 or 60 Hz)
Phase Accuracy
Frequency characteristics 40 Hz to 5 kHz: ±5 % (deviation from accuracy) 40 Hz to 5 kHz: ±3 % (deviation from accuracy)
1 mA (With 10 A AC forward and return lines) 5 mA (With 100 A AC forward and return lines)
Residual current
Effect of external magnetic
Equivalent to 5mA, 7.5A max.
Equivalent to 7.5A max.
(With a magenetic field of AC 400 A/m)
(With a magenetic field of AC 400 A/m)
fields
Less than 300 Vrms, (Insulated conductor)
Max. rated voltage to earth
φ 30 mm (1.18 in)
φ 40 mm (1.57 in)
Core diameter
Not required
Power supply
60 mm (2.36 in)W × 112.5 mm (4.43 in)H × 74 mm (2.91 in)W × 145 mm (5.71 in)H × 42
23.6 mm (0.93 in)D, 160 g (5.6 oz)
mm (1.65 in)D, 380 g (13.4 oz)
Dimensions and mass
Cord length : 3 m (9.84 ft), Output BNC terminal
Connect with the 9695-02/ -03, Output BNC terminal, 3 m (9.84 ft) length
Dimensions and mass
AC 500 mV/f.s. (AC 1 mV/ A)
±2 % rdg. ±0.3 % f.s. (at center of sensor, 45 to 66 Hz)
l CT9667 OPTION: AC ADAPTER 9445-02/-03 (DC 9 V/1 A output)
Core diameter
500 A AC
(with frequency-based deratings)
AC 500 mV/f.s. (AC 0.1 mV/ A)
Less than 600 Vrms
φ 15 mm (0.59 in)
Core diameter
Dimensions and
mass
±1° (45 Hz to 5 kHz)
40 Hz to 5 kHz: ±1.0 % (deviation from accuracy)
5000 A AC
Continuous 10000 A rms (45 to 66 Hz)
1000 A AC
Continuous 1000 Arms (45 to 66 Hz)
1000 mA AC
±3 % rdg. ±0.03 % f.s. (50/60 Hz)
(Amplitude deviation from accuracy)
40 Hz to 1 kHz: ±3 %
Less than 600 Vrms
φ 55 mm (2.17 in) or
80 mm (3.15 in) × 20 mm (0.79 in) bus-bar
78 mm (3.07 in)W × 152 mm (5.98 in)H × 42 mm 99.5 mm (3.92 in)W × 188 mm (7.40 in)H × 42 mm
(1.65 in)D, 340 g (12.0 oz), cord length: 3 m (9.84 ft), (1.65 in)D, 550 g (19.4 oz), cord length: 3 m (9.84 ft),
exclusive use 2-pin terminal
exclusive use 2-pin terminal
f.s. is the sensorʼs rated primary current value.
φ 46 mm (1.81 in)
Optical & Telecommunication
Improve productivity with Ultra-fast and High-precision measurement!
LED OPTICAL METER TM6101
Not CE Marked
■ Basic specifications (Accuracy guaranteed for 1 year)
(1) Illuminance, Luminous flux, Luminous Intensity
(2) Chromaticity
Measurement items (3) Color Rendering Index
(4) Correlated Color Temperature and Δuv
(5) Dominant wavelength and excitation purity
Measurement range [Illuminance] 5 lx to 100,000 lx
[Illuminance] ±5 % (Luminous intensity standard light bulb 1,000 lx)
Accuracy
(At 23 ± 5 °C / 80 % rh or lower, Warm-up time 60 minutes, After Dark compensation ± 5 °C, Best range setting)
Dark current compensation, Reference value compensation, (Illuminance,
Compensation
•Optical characteristic measuring instrument for white LED and LED lighting
devices
•High-precision filter system delivers high speed and high precision
•Rapid measurement with approx. 5ms at its fastest
•Stability of chromaticity values is within ± 0.0001 (3)
•Influence caused by angle of incidence is within ± 0.001 for chromaticity values
Luminous Intensity, Luminous Flux, Chromaticity)
Post-correction
backup
Interfaces
Optical detector
Measurement function
Display
Power supply
Dimensions and
mass
Note: Can be connected to an integration sphere via a 1-inch port.
Accessories
Saving of user correction values: Reference value correction values can be
saved on the connected computer
USB 2.0, Digital I/O (Input: External trigger, Output: End of measurement)
[Incoming radiation diameter] φ 11.3 mm ±0.1 mm
Control, Trigger function, Averaging, Auto-range function
Illuminance, Luminous flux, Luminous Intensity, Chromaticity, Color
Rendering Index, Correlated Color Temperature, Dominant wavelength
AC adapter 9418-15 (100 to 240 V AC, 50/60 Hz, 6 VA)
[Main unit] 210 mm (8.17 in)W × 30 mm (1.18 in)H × 135 mm (5.31 in)D, 1 kg (35.3 oz)
[Sensor unit] 70 mm (2.76 in)W × 39.5 mm (1.56 in)H × 172 mm (6.77 in)D, 550 g (19.4 oz)
AC adapter 9418-15 ×1, USB cable ×1, Main unit-Sensor Connection cable (2 m) ×1,
Light blocking cap ×1, Instruction manual ×1, CD-R (PC application software, Measurement library) ×1, Screw for connection port ×4, Ferrite core ×3
Support for a Variety of Testing Applications
Testing of white LEDs
Measurement of average luminous intensity,
chromaticity, and color rendering index
LED element
0
10
Testing of white LED lighting
Measurement of total luminous flux, chromaticity, and color rendering index
Measurement of illuminance and testing of
chromaticity and color rendering index
mm
System for measuring average luminous intensity (0.01 sr)
Primary measurement application
System for measuring total luminous flux
Customer must provide integration sphere and sensor unit mount
Measurement image
TM 6101 consists of main unit + sensor unit + PC application software.
(PC is not included)
USB
Optical &
Telecommunication
White LED/LED lighting devices
LED element
69
Optical & Telecommunication
Handy light power meter that’s ideal for testing LDs for optical discs
OPTICAL POWER METER 3664
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement items Optical power (W, dBm)
Measurable wavelength Depends on optical sensor in use (option)
Measurable power Depends on optical sensor in use (option)
±0.7 % (±5 % in combination with the optional sensor)
Accuracy
Wavelength sensi- Can be set for every 1 nm, Automatic compensation for the sensor’s sensitivity compensation tivity
19999 max. Display resolution: 0.01 dBm / 0.01 dB,
Display
Measurement display unit: nW, μW, mW, dBm, dB
Depends on optical sensor in use (option)
Analog output
(1 V approx. or 0.7 V approx. when the sensor calibration point input)
marked
Scaling, Relative measurement, Max. value/ Min. value/ Average-value
display, Auto power save, Setting backup, Battery check
USB 1.1 (Output measurement value and remote control)
LR6 (AA) alkaline batteries ×4, Continuous use : 60 hr (using with the 9742
optical sensor as correction input), or AC adapter 9445-02/-03, 1.6 VA max.
85 mm (3.35 in)W × 160 mm (6.30 in)H × 35 mm (1.38 in)D, 270 g (9.5 oz)
Functions
Optional sensor for blue-violet optical lasers only (Sold separately)
Interfaces
OPTICAL SENSOR 9743
(Handheld model)
OPTICAL SENSOR 9743-10
(Detachable model)
Dimensions and
mass
Power supply
Accessories
Bundled accessories
•4.5 digits and broad dynamic range with 0.01 dBm resolution
•Automatic correction of sensor sensitivity using measurement wavelength input
•Remote operation on a computer screen and data capture via a USB
connection
•Analog output function
Optical &
Telecommunication
OUTPUT CORD 9094
USB Cable
AC ADAPTER 9445-03
3.5 mm (0.14 in) dia. mini
1 m (3.28 ft) cord length
plug to banana, 1.5 m (4.92 ft)
length, Not CE marked
OPTICAL SENSOR
9742
OPTICAL SENSOR
9742-10
CARRYING CASE
9246
For USA, 100 to 240 V AC,
9 V/ 1 A
For EU
For blue-violet optical lasers
OPTICAL SENSOR OPTICAL SENSOR
9743
9743-10
Maximum rated value: Maximum rated value:
100 mW
100 mW
■ Optical sensor basic specifications (Accuracy guaranteed for 1 year)
9742, 9742-10
320 nm to 1100 nm
Measurable wavelength
-59 dBm to +17 dBm (at the calibration wavelength)
Measurable power
Max. rated measurable
50 mW (+17 dBm) *at all direction irradiation
power
Si photo-diode, 9.6 mm (0.38 in) × 9.6 mm (0.38 in)
Optic receptacle element
±4.3 % (±5 % in combination with the Optical power meter 3664)
Measurement accuracy
Maximum rated value:
50 mW
Maximum rated value:
50 mW
Includes compartment
for options
9743, 9743-10
380 to 450 nm
-50 dBm to + 20 dBm (at the calibration wavelength)
100 mW (+20 dBm) *at all direction irradiation
Si photo-diode, 10 mm (0.39 in) × 10 mm (0.39 in)
±4.3 % (±5 % in combination with the Optical power meter 3664)
Calibration conditions
Calibration wavelength: 633 nm, Calibration power: 100 mW, φ 2 mm parallel
beam, Perpendicular input to the center of optical sensor, by CW light
Calibration wavelength: 405 nm, Calibration power: 100 mW, φ 1.5 mm parallel
beam, Perpendicular input to the center of optical sensor, by CW light
Dimensions and mass
See outline drawings; 100 g (3.5 oz)
See outline drawings; [9743] 100 g (3.5 oz) [9743-10] 110 g (3.9 oz)
■ OPTICAL SENSOR 9742
2 m (6.56 ft) cord length
■ OPTICAL SENSOR 9742-10
2 m (6.56 ft) cord length
(can be secured with screws)
70
AC ADAPTER 9445-02
Options
*This product cannot perform measurement alone. Please
purchase an optional light sensor separately.
*Use of Optical Sensor 9743/ 9743-10 that are exclusively for
blue-violet optical lasers is not supported on earlier versions of
Model 3664 (Version 1.01 or earlier). Please visit www.hioki.com
to download the Hioki 3664 Setup Utility to enable compatibility
of the Optical Sensors with all versions of Optical Power Meter
3664.
(without batteries)
AC adapter 9445-02 (for USA) ×1 or 9445-03 (for EU) ×1, Output cord
9094 ×1, Driver software (CD-R) ×1, LR6 (AA) alkaline batteries ×4,
USB cable ×1, Strap ×1, Instruction manual ×1
■ OPTICAL SENSOR 9743
2 m (6.56 ft) cord length
(can be secured with screws)
■ OPTICAL SENSOR 9743-10
2 m (6.56 ft) cord length
(can be secured with screws)
Optical & Telecommunication
A LAN cable tester capable of identifying the location of wire breaks
LAN CABLE HiTESTER 3665-20
marked
Bundled accessories
■ Basic specifications (Accuracy guaranteed for 1 year)
Twisted-pair cable, characteristic impedance: 100 Ω, shielded and unshielded,
Measurable cable
CAT 3, 4, 5, 5e and 6
Compatible connectors RJ-45 plugs
Detectable errors: open, short, reversed, transposed, split pairs and other
Wire Map test
incorrect wiring
(Wiring condition and shielding can be confirmed using the Terminator 9690)
Measurable lengths: 2 m to 300 m (6.6 ft to 984 ft)
Measurement accuracy: ± 4 % rdg. ± 1 m (3.3 ft)
Display resolution: 0.1 m (0.3 ft)
Direction measure- Up to 21 cables can be identified using the supplied Terminator 9690 and
optional Models 9690-01 to 9690-04
ment
LR6 (AA) alkaline battery ×2, 1.4 VA max., Continuous use : 50 hr (at
Power supply
measurement interval of 1 minute)
Cable length measurement
TERMINATOR 9690
ID 0, × 1
Dimensions and
mass
85 mm (3.35 in)W × 130 mm (5.12 in)H × 33 mm (1.30 in)D, 160 g (5.6 oz)
Accessories
Terminator 9690 ×1, Carrying case ×1, LR6 (AA) alkaline battery ×2,
Instruction manual ×1
(without batteries)
CARRYING CASE
Stores the 3665-20
and 9690
•Wire map check : Detect split pairs with wiring check
•Cable length : Get NVP-Enhanced measurement accuracy
•Direction check : Identify up to 21 cable destinations
Options
For direction checks enabling individual wires to be identified, please purchase
optional Terminators 9690-01 to -04.
TERMINATOR
9690-01
TERMINATOR
9690-02
TERMINATOR
9690-03
IDs 1 to 5, 5 piece set IDs 6 to 10, 5 piece set IDs 11 to 15, 5 piece set
TERMINATOR
9690-04
IDs 16 to 20, 5 piece set
CARRYING CASE
9249
Stores the main unit
and options together
Optical &
Telecommunication
71
Environmental Measuring
Providing robust support for 3-axis magnetic flux density measurement
MAGNETIC FIELD HiTESTER FT3470-52
marked
3 cm2 Sensor
100 cm2 Sensor
• Complies with ICNIRP 2010 guidelines as well as other
relevant standards for evaluation testing.
• Complies with IEC 62110/IEEE 644 as well as IEC
62233.
• Bundled with 3 cm2 Sensor used for magnetic field
distribution analysis, and 100 cm2 Sensor used with
the IEC/EN 62233 standard analysis
• User-selectable display units (T, A/m, and G)
• Simple operation for easy measurement
• Bundled with PC application software
• Level output for RMS value, or 3-axis waveform output for magnetic
fields
■ Basic specifications (Accuracy guaranteed for 1 year)
Magnetic flux density 10 Hz to 400 kHz/ 10 Hz to 2 kHz/ 2 kHz to 400 kHz
(Bandwidth)
Exposure level
General Public/ Occupational
Single axes X, Y, Z (2000 counts), Composite RMS value R (3464 counts),
Display
Magnetic flux density (unit: T, G, A/m), Exposure level (unit: %)
[X, Y, Z axes] Effective measuring ranges: 2.000 μT to 2.000 mT, 4 ranges,
Accuracy: ±3.5% rdg. ±0.5% f.s.
[R axis] Effective measuring ranges: 3.464 μT to 3.464 mT, 4 ranges, Accuracy:
Magnetic flux density/ ±3.5% rdg. ±0.5% f.s.
[Valid measurement frequency range]
Ranges, Accuracy
at 10 Hz-400 kHz mode: 50 Hz to 100 kHz
at 10 Hz-2 kHz mode: 50 Hz to 1 kHz
at 2 kHz-400 kHz mode: 5 kHz to 100 kHz
[X, Y, Z axes] Effective measuring ranges: 20.00 % to 200.0 %, 2 ranges
Exposure level/
[R axis] Effective measuring ranges: 34.64 % to 346.4 %, 2 ranges,
Accuracy: Smoothed edges 50 Hz to 1 kHz ±3.5% rdg. ±0.5% f.s.
Ranges, Accuracy
Accuracy: Smoothed edges 1 kHz to 100 kHz ±5.0% rdg. ±0.5% f.s.
[Supporting output] Resultant RMS level output, Exposure level output, Waveform output of
magnetic flux density X/ Y/ Z each axis, Output rate: 0.1 mV/display value count
Interfaces
[USB 1.1] Data saving with the PC application
Memory function: Up to 99 measured value data, Slow function, Holds the maxiOther functions
mum value, Auto power off, Buzzer sound on/off
LR6 (AA) alkaline battery ×4, 0.8 VA (at battery operation), Continuous use of 10
Power supply
hr, or AC adapter 9445-02 (1.0 VA max. consumption)
Main unit: 100 mm (3.94 in)W × 150 mm (5.91 in)H × 42 mm (1.65 in)D, 830 g (29.3 oz),
(including batteries)
Dimensions and mass 100 cm2 Sensor: φ122 mm (4.80 in) × 295 mm (11.61 in)L, 220 g (7.8 oz)
3 cm2 Sensor: □ 27 mm (1.06 in) × 165 mm (6.50 in)L, 95g (3.4 oz)
100 cm2 Sensor ×1, 3 cm2 Sensor ×1, Instruction manual ×1, CD-R (PC application
software Data Viewer for FT3470) ×1, USB cable ×1, LR6 (AA) alkaline battery ×4,
Accessories
AC adapter (9445-02 or 9445-03 for EU) ×1, Extension cable 9758 ×1, Output cable
9759 ×1, Carrying case ×1
■ Bundled PC application software (DATA VIEWER for the FT3470)
Operating
Computer running under Windows 7 (32/64-bit), Vista (32/64-bit), XP
environment
RMS value data logging/ Save to a PC in a batch, CSV file format
Functions
Cross-sectional area: 100 cm2, Standard
sensor for use with the IEC/EN 62233
standard.
3 cm2 Sensor (Bundled accessory)
Cross-sectional area: 3 cm2, Enables
detailed analysis of magnetic field
distribution for measurement targets.
Bundled accessories
100 cm2 Sensor (Bundled accessory)
AC ADAPTER 9445-02
EXTENSION CABLE 9758
For USA, 100 to 240 V AC,
9 V/ 1 A
AC ADAPTER 9445-03
OUTPUT CABLE 9759
For EU, 100 to 240 V AC, 9
V/ 1 A
1.5 m (4.92 ft) length, to extend the length 1.5 m (4.92 ft) length, with 3-BNC
of the sensor to the instrument
connectors on the output end
Providing robust support for 3-axis magnetic flux density measurement
MAGNETIC FIELD HiTESTER FT3470-51
Environmental
Measuring
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
Magnetic flux density 10 Hz to 400 kHz/ 10 Hz to 2 kHz/ 2 kHz to 400 kHz
(Bandwidth)
Exposure level
General Public/ Occupational
Single axes X, Y, Z (2000 counts), Composite RMS value R (3464 counts),
Magnetic flux density (unit: T, G, A/m), Exposure level (unit: %)
[X, Y, Z axes] Effective measuring ranges: 2.000 μT to 2.000 mT, 4 ranges,
Accuracy: ±3.5% rdg. ±0.5% f.s.
[R axis] Effective measuring ranges: 3.464 μT to 3.464 mT, 4 ranges, Accuracy:
Magnetic flux density/ ±3.5% rdg. ±0.5% f.s.
[Valid measurement frequency range]
Ranges, Accuracy
at 10 Hz-400 kHz mode: 50 Hz to 100 kHz
at 10 Hz-2 kHz mode: 50 Hz to 1 kHz
at 2 kHz-400 kHz mode: 5 kHz to 100 kHz
[X, Y, Z axes] Effective measuring ranges: 20.00 % to 200.0 %, 2 ranges
Exposure level/
[R axis] Effective measuring ranges: 34.64 % to 346.4 %, 2 ranges,
Accuracy: Smoothed edges 50 Hz to 1 kHz ±3.5% rdg. ±0.5% f.s.
Ranges, Accuracy
Accuracy: Smoothed edges 1 kHz to 100 kHz ±5.0% rdg. ±0.5% f.s.
[Supporting output] Resultant RMS level output, Exposure level output, Waveform output of
magnetic flux density X/ Y/ Z each axis, Output rate: 0.1 mV/display value count
Interfaces
[USB 1.1] Data saving with the PC application
Memory function: Up to 99 measured value data, Slow function, Holds the maxiOther functions
mum value, Auto power off, Buzzer sound on/off
LR6 (AA) alkaline battery ×4, 0.8 VA (at battery operation), Continuous use of 10
Power supply
hr, or AC adapter 9445-02 (1.0 VA max. consumption)
Main unit: 100 mm (3.94 in)W × 150 mm (5.91 in)H × 42 mm (1.65 in)D, 830 g (29.3 oz),
(including batteries)
Dimensions and mass
100 cm2 Sensor: φ122 mm (4.80 in) × 295 mm (11.61 in)L, 220 g (7.8 oz)
100 cm2 Sensor ×1, Instruction manual ×1, CD-R (PC application software Data Viewer
for FT3470) ×1, USB cable ×1, LR6 (AA) alkaline battery ×4, AC adapter (9445-02 or
Accessories
9445-03 for EU) ×1, Extension cable 9758 ×1, Output cable 9759 ×1, Carrying case ×1
Display
100 cm2 Sensor
• Complies with ICNIRP 2010 guidelines as well as other
relevant standards for evaluation testing.
• Complies with IEC 62110/IEEE 644 as well as IEC
62233.
• Bundled with 100 cm2 Sensor used with the IEC/EN
62233 standard analysis
• User-selectable display units (T, A/m, and G)
• Simple operation for easy measurement
• Bundled with PC application software
■ Bundled PC application software (DATA VIEWER for the FT3470)
Operating
Computer running under Windows 7 (32/64-bit), Vista (32/64-bit), XP
environment
RMS value data logging/ Save to a PC in a batch, CSV file format
Functions
*The 9445-02 (or 9445-03) is bundled
100 cm2 Sensor (Bundled accessory)
72
Options
Cross-sectional area: 100 cm2, Standard
sensor for use with the IEC/EN 62233
standard.
AC ADAPTER 9445-02
EXTENSION CABLE 9758
OUTPUT CABLE 9759
For USA, 100 to 240 V AC,
9 V/ 1 A
1.5 m (4.92 ft) length, to extend
the length of the sensor to the
instrument
1.5 m (4.92 ft) length, with
3-BNC connectors on the
output end
For EU, 100 to 240 V AC, 9
V/ 1 A
AC ADAPTER 9445-03
Environmental Measuring
Non-contact infrared thermometer featuring simple, one-touch measurement
INFRARED THERMOMETER FT3700-20/FT3701-20
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
FT3700-20
FT3701-20
-60.0 to 550.0 ˚C (-76 to 1022 ˚F), 0.1 ˚C -60.0 to 760.0 ˚C (-76 to 1400 ˚F), 0.1 ˚C
Measurement temresolution
resolution
perature range
-35.0 to -0.1 ˚C (-31.0 to 31.9 ˚F) : ±10 %rdg. ±2 ˚C
0.0 to 100.0 ˚C (-32.0 to 212.0 ˚F) : ±2 ˚C
Accuracy
100.1 to 500.0 ˚C (212.1 to 932.0 ˚F) : ±2% rdg.
Note) -60.0 to -35.1 ˚C (-76.0 to -31.1 ˚F), and over 500.1 ˚C (932.0 ˚F) : Accuracy not specified
1 sec (90%)
Response time
Measurement
8 to 14 µm
wavelength
Thermal emissivity
ε=0.10 to 1.00 (0.01 step)
compensation
Measurement field φ 83 mm at 1000 mm (3.27 in at 3.28 ft) φ 100 mm at 3000 mm (3.94 in at 9.84 ft)
(Distance : Spot = 12 : 1)
(Distance : Spot = 30 : 1)
diameter
Two-beam laser marker Max 1 mW (class 2), Red
Sighting
Continuous measurement mode, MAX/ MIN/ DIF (MAX - MIN)/ AVG meaFunctions
surement, Alarm, Backlight, Auto power-off
LR03 (AAA) alkaline battery ×2, 150 mVA, Continuous use of 140 hours
Power supply
(With laser marker, backlight and buzzer are OFF)
48 mm (1.89 in)W × 172 mm (6.77 in)H × 119 mm (4.69 in)D, 256 g (9.0 oz),
Dimensions and mass (including batteries)
Instruction manual ×1, LR03 alkaline battery ×2, Carrying case ×1
Accessories
FT3700-20 Measurement distance
and field diameter
•Pistol design with easy-to-see display
φ 167 mm
•A full menu of basic measuring functions
φ 83 mm
(φ 6.57 in)
(φ 3.27 in) φ 55 mm
•Easily test in difficult locations, moving objects or where there is
(φ 2.17 in)
Measurement
danger of electric shock
field diameter
S (mm)
500 mm (1.64 ft)
FT3701-20 Measurement distance
and field diameter
φ 200 mm
(φ 7.87 in)
φ 100 mm
(φ 3.94 in)
Measurement
field diameter
S (mm)
1000 mm (3.28 ft)
1000 mm (3.28 ft)
3000 mm (9.84 ft)
2000 mm (6.56 ft)
Distance D (mm)
6000 mm (19.69 ft)
Distance D (mm)
Bundled accessory
Laser Product Caution Notice
A caution label is attached to the thermometer. Be sure to observe
the operating precautions on the label.
φ 52 mm
(φ 2.05 in)
Carrying case
Convenient measurement of sound levels from electrical equipment and machinery
SOUND LEVEL METER FT3432
■ Basic specifications (Accuracy guaranteed for 1 year)
marked
Sound level, Equivalent continuous sound level, Sound exposure level,
Measurement funcMaximum Sound level, C weighting peak sound level (measurement postions
sible only when peak range is selected)
Measurement times
Frequency weighting characteristics
Measurement level
range
Frequency range
Microphone
Time weighting
characteristics
Wind screen
WS-14 (Bundled)
Output
Power supply
Dimensions and mass
Hand strap VM-63-017
(Bundled)
IEC 61672-1: 2002 Class 2, JIS C 1509-1:2005 Class2
Accessories
1/5/10 minutes, or 1 hour
Environmental
Measuring
Applicable standards
A weighting, or C weighting
[Wide range] A weighting: 30dB to 130dB, C weighting: 36dB to 130dB
[Peak range] A weighting: 65dB to 130dB, C weighting: 65dB to 130dB
20 Hz to 8000 Hz
1/2-inch electret condenser microphone
Fast, or Slow
DC output connector: DC output: 3 V (full scale), 25 mV/dB, Output impedance: 50 Ω
AC monitor output connector: AC output: 1 Vrms +600 mVrms, -400
mVrms (at 110 dB) (Upper limit: 1.8 Vrms), Output impedance: 600 Ω,
Frequency weighting characteristics: Z weighting
LR03 (AAA) alkaline battery ×2, Continuous use 9 hr at wide range, R03 (AAA)
manganese battery ×2, Continuous use 3 hr at wide range, Consumption: 80 mA
63 mm (2.48 in)W × 120 mm (4.72 in)H × 23.5 mm (0.93 in)D, 105 g (3.7 oz),
(including batteries)
Wind screen WS-14 ×1, Hand strap VM-63-017 ×1, Windscreen fall out
prevention rubber NL-27-014 ×1, Silicon cover NL-27-026 ×1, Carrying
Case 9757 ×1, LR03 (AAA) alkaline batteries ×2, Instruction manual ×1
•Simple operation, no range switching needed
•Compact, lightweight design for easy one-handed operation
•30 dB to 130 dB
•Analog output
*Carrying case 9757 is bundled
Tripod ST-80
Options
AC MONITOR OUTPUT
CABLE CC-98A
DC OUTPUT CABLE
CC-98D
Extension Rod
ST-80-100
CARRYING CASE
9757
Soft type
73
Environmental Measuring
Wide measurement range from -100°C to 1300°C
TEMPERATURE HiTESTER 3441, 3442
marked
■ Basic specifications (Accuracy guaranteed for 6 months)
3441
3442
K type thermocouple, (Chromel / Almel)
Sensor
-100 °C to 1300 °C
Measurement range The actual measurement range is restricted by the temperature probe
(0.1 °C Resolution/ -100 °C to 199.9 °C, 1°C Resolution/ 200 °C to 1300 °C)
±0.1 % rdg. ±0.8 °C (-100 °C to 199.9 °C)
±0.2 % rdg. ± 1 °C (200 °C to 1300 °C)
*Accuracy of temperature sensor is added
Unit accuracy
Water-resistant
Construction
Sampling rate
Contact compensation
3442
3441
•Model 3442 : Waterproof construction
•-100 to 199.9 ˚C: 0.1 ˚C resolution, 200 ˚C to 1300 ˚C: 1 ˚C resolution
•More than 200 hours (1 week) of continuous operation on a single battery
•Max./Min. value recording function and sensor disconnection check function
N/A
IP 54 (EN 60529: 1991)
2 times/s
Auto compensation
Max/Min data recording and display, display data hold, sensor broken down display,
Functions
auto power save, low battery warning
R6P (AA) manganese battery ×4, or LR6 (AA) alkaline battery ×4, Continuous use : 200 hr or better (with manganese battery),
Power supply
Max. rated consumption : 35 mVA
Dimensions and mass 74 mm (2.91 in)W × 155 mm (6.10 in)H × 24 mm (0.94 in)D, 160 g (5.6 oz)
R6P (AA) manganese battery ×4, Strap band ×1, Instruction manual ×1
Accessories
Option
• Model 3441 (°C only)
• Model 3441-02 (°C/°F selectable)
• Model 3442 (°C only, waterproof construction)
These products cannot perform measurement alone. Please purchase a temperature
probe separately.
For the 3441/42, 3446/47
■ Probe specifications (9472, 9473, 9474, 9475: Waterproof construction)
■ Probe specifications
Model
9472
9473
9474
9475
9476
K type thermocouple (Chromel / Almel)
Material type
Non-grounded Non-grounded Non-grounded Non-grounded
Grounded
Contact type
*2
*3
Tolerance
About 5 sec
About 10 sec
About 5 sec
About 10 sec
About 3 sec
Response (90%)*1
φ 2.3 × 150 (mm) φ 4.8 × 300 (mm) φ 2.3 × 100 (mm) φ 4.8 × 100 (mm)
φ 20 (mm)
Size of Sheath
φ 0.09 × 5.91 (in) φ 0.19 × 11.81 (in) φ 0.09 × 3.94 (in) φ 0.19 × 3.94 (in)
φ 0.79 (in)
(mm), (inch)
Conventional type (-20 to 90˚C, -4 to 194˚F), 1m (3.28 ft)
Compensation lead
80 ˚C (176 ˚F)
Grip heat resistance
−100 to 300 °C
0 to 800 °C
−100 to 300 °C −100 to 500 °C −40 to 500 °C
Measurement
–148 to 572 °F
32 to 1472 °F
–148 to 572 °F –148 to 932 °F –40 to 932 °F
temp.
Model
Material type
Contact type
*1 Sheath type: Responsiveness in ice water at 0 °C (32 °F) and in boiling water at 100 °C (212 °F)
Surface type: Responsiveness on a metal surface at 0 °C (32 °F) and at 100 °C (212 °F)
*2 At -40 °C (-40 °F ) and more , the greater of ±1.5 °C (±2.7 °F) and ±0.4 % of the measured value
*3 ±2.5 °C [ (T-Ts) ≤ 100°C ], -0.03 × T °C to +2.5 °C [100 °C < (T-Ts) ],
T : measured temperature (-40 °C to 500 °C), Ts : environmental temperature (0 °C to 40 °C)
CARRYING CASE
9386-01
9180, 9183
Non-grounded
9181
K type thermocouple (Chromel / Almel)
Grounded
9180 : *4
9183 : *2
±2.5 ˚C (±4.5 ˚F ) [(T-Ts) ≤ 100 ˚C (180 ˚F )]
−0.035×T ˚C to +2.5 ˚C [100 ˚C (180 ˚F ) < (T-Ts)]
T: measurement temp. (-50 °C to 400 °C)
Ts: environment temp. (0 °C to 50 °C)
Response (90%)*1
Size of Sheath
(mm), (inch)
Compensation
lead
About 5 sec
φ 3.2 × 150 (mm)
φ 0.13 × 5.91 (in)
About 3 sec
φ 13 (mm)
φ 0.51 (in)
Grip heat resistance
150 °C (302 °F), Grip size φ 13 × 100 mm (φ0.51 in × 3.94 in)
Tolerance
Measurement
temp.
Conventional type (-20 to 90˚C, -4 to 194˚F), 1m (3.28 ft)
−50 to 750 °C
–58 to 1382 °F
−50 to 400 °C
–58 to 752 °F
9182
Non-grounded
*4
About 5 sec
φ 3.2 × 500 (mm)
φ 0.13 × 19.69 (in)
Heat resisting type (0 to 150
°C, 32 to 302 °F) 2m (6.56 ft)
90 °C (194 °F), clamp size φ 8
× 30 mm (φ 0.31 × 1.18 in)
−50 to 750°C
–58 to 1382°F
Environmental
Measuring
*1 Sheath type: Responsiveness in ice water at 0 °C (32 °F) and in boiling water at 100 °C (212 °F)
Surface type: Responsiveness on a metal surface at 0 °C (32 °F) and at 100 °C (212 °F)
*2 At -40 °C (-40 °F ) and more , the greater of ±1.5 °C (±2.7 °F) and ±0.4 % of the measured value
*4 At -40 °C (-40 °F ) and more , the greater of ±2.5 °C (±4.5 °F ) and ±0.75% of the measured value
unit=mm
SHEATH TYPE TEMPERATURE PROBE 9472
SHEATH TYPE TEMPERATURE PROBE 9474
K type, Size of Sheath: φ 2.3 mm (0.09 in) × 100 mm (3.94 in),
1 m (3.28 ft) Cord length
SHEATH TYPE TEMPERATURE PROBE 9475
K type, Size of Sheath: φ 4.8 mm (0.19 in) × 100 mm (3.94 in),
1 m (3.28 ft) Cord length
Temperature probes
Temperature probes
K type, Size of Sheath: φ 2.3 mm (0.09 in) × 150 mm (5.91 in),
1 m (3.28 ft) Cord length
SHEATH TYPE TEMPERATURE
PROBE 9473
unit=mm
unit=mm
unit=mm
SHEATH TYPE TEMPERATURE PROBE 9180
K type, Size of Sheath: φ 3.2 mm (0.13 in) × 150 mm (5.91 in),
1 m (3.28 ft) Cord length
SHEATH TYPE TEMPERATURE PROBE 9183
K type, Size of Sheath: φ 3.2 mm (0.13 in) × 150 mm (5.91 in),
1 m (3.28 ft) Cord length
length
unit=mm
K type, Size of Sheath: φ 4.8 mm (0.19 in) × 300
mm (11.81 in), 1 m (3.28 ft) Cord length
unit=mm
SURFACE TEMPERATURE PROBE 9181
K type, Tip dia.: φ 13 mm (0.51 in), 1 m (3.28 ft) Cord
SURFACE TYPE TEMPERATURE PROBE 9476
K type, Tip dia. φ 20 mm (0.79 in), 1 m (3.28 ft) Cord length
SHEATH TYPE TEMPERATURE PROBE 9182
K type, Size of Sheath: φ 3.2 mm (0.13 in) × 500 mm (19.69 in),
Note: The 9472 to 9475 are waterproof probes. When used with Model 3442, you can achieve a
complete water-resistant temperature measuring system.
2 m (6.56 ft) Cord length
Options for the TEMPERATURE HiTESTER 3446-01, 3447-01 (both models are discontinued) *The 9478 is used for the LCR METER IM3533/3533-01
For Model 3446-01
For Model 3447-01 *The 9478 is used for the LCR METER IM3533/3533-01
Tip: slate spring
SHEATH TYPE TEMPERATURE PROBE 9472-50
K type, Size of Sheath: φ 2.3 mm (0.09 in) × 150 mm (5.91 in), 1
m (3.28 ft) Cord length
SHEATH TYPE TEMPERATURE PROBE 9473-50
K type, Size of Sheath: φ 4.8 mm (0.19 in) × 300 mm (11.81 in),
1 m (3.28 ft) Cord length
74
SURFACE TYPE TEMPERATURE PROBE
9476-50
K type, Tip dia. φ 20 mm (0.79 in), 1 m (3.28 ft) Cord
length
SHEATH TYPE TEMPERATURE PROBE 9478
Pt100 type, Tip dia. φ 2.3 mm (0.09 in), 1 m (3.28 ft) Cord
length
Discontinued
SHEATH TYPE TEMPERATURE PROBE 9479
Pt100 type, Tip dia. φ 2.3 mm (0.09 in), Hand switch, 1 m (3.28 ft)
Cord length, waterproof construction
Environmental Measuring
Digital illumination meter, maximum scale of 199,900 lx
LUX HiTESTER 3423
marked
•Easy-to-operate, hand-held unit
•From low light up to a maximum
intensity of 199,900lx
•For illumination equipment, lighting
work, and facility management
■ Basic specifications (Accuracy guaranteed for 2 years)
LCD 3-1/2 digit, Max. "1999"
Display
Display operation 20,000 lx range: "19990", 200,000 lx range: "199900"
20/ 200/ 2,000 lx ranges :1-count step
Measurement
20,000 lx range :10-count steps
ranges
200,000 lx range :100-count steps, Auto/manual switching
± 4 % rdg. ± 1 dgt. (23 °C ± 5 °C) (73 ± 9 °F)
Accuracy
Auto range: 5 s or less, Manual range: 2 s or less
Response time
Receptor element Silicon photo-diode
200 mV DC f.s., Output accuracy: ± 2.5 % f.s. (versus the display value)
Analog output
R6P (AA) manganese battery ×2, Continuous use 25 hr, LR6 (AA) alkaline
Power supply
battery ×2, Max. rated consumption : 600 mVA
Dimensions and
74 mm (2.91 in)W × 170 mm (6.69 in)H × 30 mm (1.18 in)D, 310 g (10.9 oz)
(including batteries)
mass
Light sensor cap ×1, R6P (AA) manganese battery ×2, Carrying case 9376 ×1,
Accessories
Instruction manual ×1
■ Options
CARRYING CASE 9376
Bundled with the 3423
3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m
(4.92 ft) length, Not CE marked
Option
OUTPUT CORD 9094
CONNECTING CABLE 9436
Separate the light sensor from
the main unit, 2 m (6.56 ft) length
(Bundled the case)
Rugged design and optimal functionality
TACHO HiTESTER FT3405, FT3406
•Convenient analog and pulse output
functions
•Dust-proof construction and drop-proof
to 1 meter
•Wide measurement range of 0.5000 r/s
(30.00 r/min) to 99990 r/min
•Contact style testing available with optional
contact adapter
•Convenient analog and pulse output functions (FT3406 only)
•Optional AC Adapter power supply (FT3406
only)
*Using with the Peripheral ring 9212 (option)
Accuracy
FT3406
Options
(includes 9212 ×1, 9033 ×2,
9032 ×1), set model
RUBBER CONTACT METAL CONTACT
TIP 9033
TIP 9032
*Output cord 9094 is bundled with the FT3406 only, AC adapter Z1004 is for use with the FT3406 only
Other options
REFLECTIVE TAPE 9211
30 pieces/sheet, 10 sheets/1 set,
12 mm (0.47 in) × 12 mm (0.47
in) per piece
Up to 9999 counts: ±1 dgt. (AVG= ON), ±10 dgt. (AVG= OFF)
10000 counts or more: ±2 dgt. (AVG= ON), ±20 dgt. (AVG= OFF)
20000 counts or more (r/min mode only) : ±20 dgt. (AVG= ON), ±100 dgt.
(AVG= OFF)
Straight-line speed measurement only: ±0.5 % rdg. add to above-mentioned
accuracy
CONTACT ADAPTER
Z5003
PERIPHERAL
RING 9212
FT3405
FT3406
Non-contact: Using red visible-spectrum light and reflective tape
Contact: Using optional Contact Adapter
Rotation (r/min) : (30.00 to 199.99) to (20000 to 99990)
Measurement ranges Rotation (r/s) : (0.5000 to 1.9999) to (200.0 to 1600.0)
Non-contact, AVG=ON
Period (ms) : (0.6000 to 1.9999) to (200.0 to 1999.9)
Count : 0 to 999999
Rotation (r/min) : (15.00 to 199.99) to (2000 to 19999)
Measurement ranges Rotation (r/s) : (0.2500 to 1.9999) to (200.0 to 333.00)
Contact, AVG=ON
Period (ms) : (3.000 to 19.999) to (200.0 to 3999.9)
Count : 0 to 999999
Straight-line speed (meter/min) : (1.500 to 19.999) to (200.0 to 1999.9)
Measurement ranges Straight-line speed (meter/s) : (0.0250 to 1.9999) to (20.00 to 33.30)
Contact, AVG=ON
Measurement
method
Environmental
Measuring
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
Accessories
OUTPUT CORD 9094
3.5 mm (0.14 in) dia. mini plug to
banana, 1.5 m (4.92 ft) length, Not
CE marked
Non-contact measur50 mm (1.97 inch) to 500 mm (19.7 inch)
ing detection range
Display refresh rate Approx. 0.5 to 10 times/s
[Analog output] 0 to 1 V f.s., Accuracy: ±2 % f.s.,
Output resistance: 1 kΩ
Functions
N/A
(FT3406 only)
[Pulse output] 0 to 3.3 V, Output resistance: 1 kΩ
Can use with the AC adapter for power supply
IP50 (EN60529)
IP50 (EN60529)
Dust and water proof
MAX/MIN display, Display hold, Average, Auto power save, Buzzer sound,
Common functions
Drop-proof (1 m distance onto concrete surface)
LR6 (AA) alkaline battery ×2, Max. rated consumption 0.5 VA
Power supply
Continuous use 30 hr
Continuous use 25 hr
Operating time
N/A
AC adapter Z1004
AC power supply
71 mm (2.80 in)W × 186 mm (7.32 in)H × 38 mm (1.50 in)D, 230 g (8.1 oz)
Dimensions and mass (including batteries)
AC ADAPTER Z1004
Instruction manual ×1, Reflective tape 9211
Instruction manual ×1, Reflective tape
×1 sheet (30 pieces/ 12 mm (0.47 in) × 12
9211 ×1 sheet (30 pieces/ 12 mm (0.47 in)
mm (0.47 in) per piece), Output cord 9094
× 12 mm (0.47 in) per piece), Carrying
×1, Carrying case ×1, LR6 (AA) alkaline
case ×1, LR6 (AA) alkaline battery ×2
battery ×2
75
DMM/Testers
Table of Specifications (Representative figures are provided for basic accuracy. For more information, please see the product catalog.)
Model
High precision models
DT4281
DT4282
DT4251
Standard models
DT4252
Electrical work
General use
○
True RMS
6000
○
DT4253
Pocket models
DT4221
DT4222
Appearance
Basic Specifications
Principal applications
Electrical work
General use
Electrical work
General use
Rectifier
Maximum display count
Display backlight function
Probe sleeve
attached
CAT
No probe sleeve
attached
Measurement range
CAT IV 600V/CAT III 1000V
CAT IV 600V/CAT III 1000V
CAT IV 300V/CAT III 600V
CAT II 1000V
CAT II 1000V
CAT II 600V
AC/DC Voltage
60.000 mV/600.0 mV/6.0000 V/
60.000 V/600.00/1000.0 V
True RMS
60000
○
○
Accuracy (DC V)
±0.025% rdg. ±2 dgt.
Accuracy (AC V)
±0.2% rdg. ±25 dgt.
6.0000 V/60.000 V
600.00 V/1000.0 V
±0.3% rdg. ±30 dgt.
600.00 µA/6000.0 µA
600.00 µA/6000.0 µA
60.000 mA/600.00 mA
60.000 mA/600.00 mA
6.0000 A/10.000 A
±0.05% rdg. ±5 dgt.
±0.6% rdg. ±5 dgt.
AC+DC Voltage
Accuracy
AC/DC Current
(Direct input)
Accuracy (DC A)
Accuracy (AC A)
AC Current
(Clamp sensor)
10.00 A to 1000 A
N/A
±0.6% rdg. ±2 dgt.
Accuracy
Resistance
Accuracy
Temperature (thermocouples)
Accuracy
Capacitance
Accuracy
Frequency
Combined accuracy:
Add AC clamp’s measurement accuracy.
N/A
1.000 nF/10.00 nF/100.0 nF/1.000 µF/10.00
µF/ 100.0 µF/1.000 mF/10.00 mF/100.0 mF
True RMS
6000
○
*600.0 mV
6.000 V/60.00 V
600.0 V/1000 V
*High accuracy 600.0 mV
6.000 V/60.00 V
600.0 V/1000 V
*600.0 mV
6.000 V/60.00 V
600.0 V/1000 V
(* DC only)
(* DC only)
(* DC only)
○
*600.0 mV
6.000 V/60.00 V/600.0 V
(* DC only)
±0.5% rdg. ±5 dgt.
±1.0% rdg. ±3 dgt.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
6.000 A/10.00 A
N/A
*60.00 µA/*600.0 µA
*6.000 mA/*60.00 mA
N/A
N/A
±0.8% rdg. ±5 dgt.
N/A
N/A
N/A
N/A
N/A
10.00 A to 1000 A
N/A
N/A
N/A
N/A
(* DC only)
N/A
N/A
±0.9% rdg. ±5 dgt.
±1.4% rdg. ±3 dgt.
10.00 A to 1000 A
N/A
Combined accuracy:
Add AC clamp’s measurement accuracy.
N/A
N/A
±0.9% rdg. ±3 dgt.
N/A
600.0 Ω/6.000 kΩ/
60.00 kΩ/600.0 kΩ/
6.000 MΩ/60.00 MΩ
±0.7% rdg. ±5dgt.
N/A
N/A
Combined accuracy:
Add AC clamp’s measurement accuracy.
N/A
K: -40.0 to 400.0 °C
±0.5% rdg. ±2 °C
1.000 µF/10.00 µF/100.0 µF/1.000 mF/10.00 mF
DMM
Tester s
±1.0% rdg. ±5 dgt.
ACV, DC+ACV, ACA
±1.9% rdg. ±5 dgt.
(limited by range in some cases)
ACV, DC+ACV, ACA (limited by range in some cases)
99.99 Hz/999.9 Hz/9.999 kHz/99.99 kHz
99.999 Hz/999.99 Hz/9.9999 kHz/
99.999 kHz/500.00 kHz
±0.005% rdg. ±3 dgt.
○
○
○
○
N/A
○
N/A
N/A
○
±0.3% rdg. ±5 dgt.
High accuracy 600.0 mV range: ±0.2%rdg. ±5 dgt.
±0.9% rdg. ±3 dgt.
±0.9% rdg. ±3 dgt.
60.000 Ω/600.00 Ω/6.0000 kΩ/
60.000 kΩ/600.00 kΩ/6.0000 MΩ/
60.00 MΩ/600.0 MΩ
±0.03% rdg. ±2 dgt.
K: -40.0 to 800.0 °C
±0.5% rdg. ±3 °C
±0.1% rdg. ±1 dgt.
Accuracy
○
○
○
Continuity check
○
○
○
Diode check
N/A
N/A
N/A
Conductance
○
N/A
N/A
Voltage detection
AC/DC voltage
AC/DC dual display AC/DC dual display
○
N/A
○
automatic detection
○
○
N/A
N/A
N/A
Decibel conversion
○
○
N/A
N/A
N/A
Peak measurement
○
○
N/A
N/A
○
4-20 mA % conversion
Filter function, Display hold, Auto hold, Max/
Min value display, Sampling select, Relative Filter function, Display hold, Auto hold, Max/Min/Avg value display,
Other functions
display, Memory function (400 data), AutoRelative display, Auto-power save, USB communication (option)
power save, USB communication (option)
LR6 (AA) alkaline batteries ×4, 100 hours
Power supply/
Manganese(R6P) battery ×4, 30 hours
Alkaline batteries (LR03) × 4, 130 hours
Continuous use
(Backlight off)
[Representative value: DCV function]
93 mm (3.66 in)W × 197 mm (7.76 in)H× 53
84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
Dimensions and mass
mm (2.09 in)D, 650 g (22.9 oz)
390 g (13.8 oz) (including batteries and holster)
(including batteries)
76
Air-conditioning/
instrumentation
N/A
N/A
N/A
N/A
600.0 Ω/6.000 kΩ/
60.00 kΩ/600.0 kΩ/
6.000 MΩ/60.00 MΩ
±0.9% rdg. ±5dgt.
N/A
N/A
1.000 µF/10.00 µF/
100.0 µF/1.000 mF/
10.00mF
±1.9% rdg. ±5 dgt.
99.99 Hz/999.9 Hz/9.999 kHz
±0.1% rdg. ±2 dgt.
○
N/A
N/A
○
○
○
N/A
N/A
○
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Filter function, Display hold,
Relative display, Auto-power save
Alkaline batteries (LR03) × 1, 40 hours
72 mm (2.83 in)W × 149 mm (5.87 in)H× 38
mm (1.50 in)D, 190 g (6.7 oz)
(including batteries and holster)
DMM/Testers
Table of Specifications (Representative figures are provided for basic accuracy. For more information, please see the product catalog.)
Model
Pocket size DMM
3245-60
3244-60
3246-60
Handheld DMM
3255-50
4199
N/A
CAT IV 300V
CAT III 600V
4199
○
CAT IV 300V
CAT III 600V
4199
N/A
CAT III 600V
CAT II 1000V
CAT II 600V
CAT II 600V
CAT II 1000V
Appearance
Basic Specifications
AC measurement method
Maximum display count
Display backlight function
Probe sleeve
attached
CAT
No probe sleeve
attached
Measurement range
AC/DC Voltage
MEAN
4199
N/A
CAT III 300V
CAT II 600V
*419.9 mV
*419.9 mV
4.199 V
41.99 V
419.9 V
500 V
4.199 V
41.99 V
419.9 V
600 V
(* DC only)
Accuracy (DC V)
Accuracy (AC V)
419.9 mV
4.199 V
41.99 V
419.9 V
1000 V
(* DC only)
±0.7% rdg. ±4dgt.
±1.3% rdg. ±4 dgt.
±2.3% rdg. ±8 dgt.
±0.5% rdg. ±4dgt.
±1.2% rdg. ±4dgt.
AC/DC Current
(Direct input)
N/A
N/A
N/A
N/A
Accuracy (DC A)
Accuracy (AC A)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
AC Current
(Clamp sensor)
N/A
N/A
N/A
Accuracy
N/A
N/A
N/A
10.00 A to 1000 A
(with optional clamp sensor)
±2.0% rdg. ±4dgt.
419.9 Ω
4.199 kΩ
41.99 kΩ
419.9 kΩ
4.199 MΩ
41.99 MΩ
Resistance
Power supply
Continuous use
±2.0% rdg. ±4 dgt.
Threshold 50 Ω ± 40 Ω
N/A
○ (Judgment only)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
○
Auto only
○
Auto/Manual
○
N/A
N/A
N/A
○
Auto/Manual
2.5 times/s
Coin type lithium battery
(CR2032) × 1
150 hours
Main battery: Rechargeable
lithium battery
Coin type lithium battery Manganese batteries (R03)
Backup battery: Coin type
(CR2032) × 1
×2
lithium battery (CR2032) × 1
150 hours (Backup battery)
Other functions
Dimensions and mass
○
Auto/Manual
±0.7% rdg. ±4dgt.
55 mm (2.17 in)W × 109
mm (4.29 in)H × 9.5 mm
(0.37 in)D, 60 g (2.1 oz)
DMM
Tester s
Accuracy
Continuity buzzer
Diode check
Frequency
Capacitance
Temperature
Functions
Auto power save
Range switching
Sampling rate
Combined accuracy: Add
AC clamp’s measurement
accuracy.
150 hours
200 hours
Light check function
LED light illuminates
test points
Backlight LCD
Dust-proof and waterproof
structure
Built-in with currentlimiting resistor and 1000
V withstanding fuse to
prevent short-circuit accidents
60 mm (2.36 in) W × 135
mm (5.31 in) H × 23 mm
(0.91 in) D, 140 g (4.9 oz)
30mm(1.18in) W ×
182mm(7.17in) H ×
26.5mm(1.04in) D,
80g(2.8oz)
70 mm (2.76 in) W × 145
mm (5.71 in) H × 31 mm
(1.22 in) D, 210g (7.4 oz)
(including batteries)
Test lead L9207-10/ L9207-30
Sleeve
CAT IV 600V When the CAT (measurement category) rating of the main unit is lower
Sleeve attached
CAT III 1000V than that of test leads, the CAT of the main unit takes precedence.
When measuring in a CAT IV or CAT III environment, be sure to attach
No sleeve attached CAT II 1000V the sleeve to the test leads.
77
DMM/Testers
Speedy Performance of Professional Testing - Two Models Provide High Accuracy and Fast Response
DIGITAL MULTIMETER DT4281, DT4282
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
■ Basic specifications (Accuracy guaranteed for 1 year)
CAT IV 600 V
CAT III 1000 V
DC Voltage
AC Voltage
45 to 65 Hz
Option
DC + AC Voltage
45 to 65 Hz
Resistance
DC Current
AC Current
45 to 65 Hz
AC Current
(use with Clamp on
probes) 40 to 1 kHz
DT4282
DT4281
•60,000 count, 5-digit display, high-resolution measurements
•±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V
frequency characteristics
•Low-pass filter cuts high harmonics
(when measuring inverter fundamental waveforms)
• Includes multiple measurement functions such as DC+ACV,
temperature, capacitance, and frequency
• Includes terminal shutter mechanism for accident prevention
(prevents erroneous test lead insertion)
• Measures large currents with optional clamp probe
(only for DT4281, which has no 10 A terminal for accident prevention)
• USB communications function supports PC measurements (optional)
• Broad -15 (5°F) to 55°C (131°F) operating temperature range
Peak
C (capacitance)
Continuity check
DT4281
DT4282
60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy: ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy: ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)
Basic accuracy: ±0.03 % rdg. ±2 dgt.
600.00 μA to 600.00 mA, 4 ranges
600.00 μA to 10.000 A, 6 ranges
Basic accuracy: ±0.05 % rdg. ±5 dgt.
600.00 μA to 600.00 mA, 4 ranges
600.00 μA to 10.000 A, 6 ranges
Basic accuracy: ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
10.00 A to 1000 A, 7 ranges
N/A
Add the Clamp on probe accuracy to
Basic accuracy: ±0.6 % rdg. ±2 dgt.
(True RMS, crest factor 3)
N/A
DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated)
1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less,
Threshold of forward voltage: 0.15 V to 3 V, seven stages
AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt.
Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV)
K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) (use with optional probe DT4910)
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C
Filter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value
hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement
memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion
Diode test
Frequency
dB conversion
Temperature
Other functions
Main and Sub displays: 5-digits LCD, max. 60000 digits
Display
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours
Power supply
Dimensions and
93 mm (3.66 in)W × 197 mm (7.76 in)H× 53 mm (2.09 in)D,
650 g (22.9 oz) (including test leads holder and batteries)
mass
Test lead L9207-10 ×1, Instruction manual ×1, LR6 alkaline battery ×4
Accessories
DT4281, DT4282 Options in Detail
Test leads
TEST LEAD L9207-10
90 cm (2.95 ft) length, for
DT4280s/4250s, 3256s, 3281s,
or other
Current measurement
Options for the L9207-10 (L9207-10 is a bundled accessory)
CONTACT PIN SET L4933 SMALL ALLIGATOR CLIP
Attaches to the tip of the
SET L4934
Test lead L9207-10/DT4911,
DC70V/AC33V
Attaches to the tip of the Test lead L920710/DT4911, CAT III 300V, CAT II 600V
Clamp on current sensors for the DT4281
CONVERSION
ADAPTER 9704
Receiving end: Female BNC; Output end:
Male banana-plug *Not compatible with
older generation MEMORY HiCORDERs
with banana input terminals
CLAMP ON
CLAMP ON PROBE CLAMP ON PROBE
PROBE 9010-50 9018-50
9132-50
10 to 500 AAC, φ46
Wide-band type, 10 to 500 20 to 1000 AAC, φ55 mm (φ2.17
mm (φ1.81 in), 3 m (9.84 AAC, φ46 mm (φ1.81 in),
in) or 80×20 mm (3.15×0.79 in), 3 Note: Use with the Conversion Adapter 9704, required for
connecting Clamp On Probes to DT4281
ft) length
3 m (9.84 ft) length
m (9.84 ft) length
Options for the L4930
Options for Test leads
DMM
Tester s
CONNECTION CABLE EXTENSION CABLE
SET L4930
SET L4931
1.2 m (3.94 ft) length
TEST PIN SET L4932
Expand length the L4930, 1.5
m (4.92 ft) length
K type, tip exposed, 0.3 mm (0.01 in)
diameter, 80 cm (2.62 ft) length, -40 to 260 °C
(-40 to 500 °F)
Other options
Temperature measurement
THERMOCOUPLES(K) DT4910
Attaches to the tip of the
Cord L4930, CAT IV 600V,
CAT III 1000V
BUS BAR CLIP SET
L4936
Attaches to the tip of the Cord L4930,
CAT IV 600V, CAT III 1000V
Attaches to the tip of the Cord Attaches to the tip of the Cord
L4930, CAT III 600V
L4930, CAT III 1000V
COMMUNICATION
PACKAGE(USB) DT4900-01 MAGNETIC STRAP
For DT4280s/4250s, compatible with
Z5004
Windows 8/7/Vista/XP
Ideal for checking ripple voltage in DC supply systems
DC
ACV
Peak measurement function & DC+AC voltage measurement
Capture ripple voltage component on direct current signals.
Input
waveform
DC+AC measurement
100 V
−PEAK measurement
85.9 V
+PEAK measurement
114.1 V
MAGNETIC ADAPTER
SET L4937
GRABBER CLIP 9243
Attaches to the tip of the Cord
L4930/9197/9322 or other, CAT III
1000 V, 196 mm (7.72 in) length
CARRYING CASE
C0202
For the DT4280, DT4250 series
Optimized for inverter system measurements
LPF
1kHz
+
78
ALLIGATOR CLIP SET
L4935
Refer to the detailed catalog
Filter off
0V
Filter on
0V
Low-pass filter cuts harmonic
waveform components
The (1 kHz cutoff) low-pass filter
function cuts high
harmonic components when measuring the secondary output voltage
of an inverter.
Typical waveform + harmonic components
Typical waveform component
DMM/Testers
Speedy Performance of Professional Testing - Standard Models Provide Safety and Fast Response
DIGITAL MULTIMETER DT4251, DT4252, DT4253
CAT IV 600 V
CAT III 1000 V
Regarding DMM Accuracy
■ Basic specifications (Accuracy guaranteed for 1 year)
DT4251
DT4252
DT4253
600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt.
DC Voltage
6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz
AC Voltage
40 to 500 Hz
Option
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for
reference. Please refer to the individual catalogs for detailed accuracy information.
Resistance
DC Current
Basic accuracy
AC Current
Basic accuracy: ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt.
N/A
40 to 500 Hz
N/A
Basic accuracy
AC Current
(use with Clamp on
probes) 40 to 1k Hz
6.000 A / 10.00 A, 2 ranges
±0.9 % rdg. ±5 dgt.
60.00 μA to 60.00 mA, 4 ranges
±0.8 % rdg. ±5 dgt.
6.000 A / 10.00 A, 2 ranges
±1.4 % rdg. ±3 dgt.
N/A
(True RMS, crest factor 3, 40 Hz to 1kHz)
10.00 A to 1000 A, 7 ranges
10.00 A to 1000 A, 7 ranges
Add the Clamp on probe accuracy to
basic accuracy: ±0.9 % rdg. ±3 dgt.
(True RMS, crest factor 3)
N/A
Add the Clamp on probe accuracy to
basic accuracy: ±0.9 % rdg. ±3 dgt.
(True RMS, crest factor 3)
Temperature
K: -40.0 to 400.0 °C
(use with DT4910)
DT4253
DT4252
DT4251
•±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
•Low-pass filter (100 Hz/ 500 Hz) cuts high harmonics
• Includes multiple measurement functions such as temperature (only for
DT4253), capacitance, and frequency
• Measures large currents with optional clamp on probe (only for
DT4251,DT4253)
•Current input terminal eliminated to enhance safety (only for DT4251)
• USB communications function supports PC measurements (optional)
• Broad -10 (14°F) to 50°C (122°F) operating temperature range
DT4251, DT4252, DT4253 Option
Basic accuracy
Voltage detection
C (capacitance)
Frequency
Continuity check
Diode test
Other functions
Display
Display refresh rates
Power supply
Dimensions and
mass
Accessories
N/A
N/A
Add the Temperature probe accuracy
to basic accuracy: ±0.5 % rdg. ±2 °C
80 V to 600 V AC
N/A
N/A
1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges
Only for AC V measurement: 99.99 kHz, Basic accuracy: ±0.1 % rdg. ±1 dgt.
Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED),
[OFF]: 245 Ω or more, Response time: 0.5 ms or more
Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less,
Threshold of forward voltage: 0.15 V to 1.5 V
Filter function, Display value hold, Auto hold, Max/Min/Average value display,
Relative display, Auto-power save, USB communication (option)
Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value,
Frequency: 1 to 2 time/s, Temperature: 1 time/s )
LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
390 g (13.8 oz) (including batteries and holster)
Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline
battery ×4
Option
CARRYING CASE
C0201
Other options are the same as for the DT4280 series
For the DT4250 series
Speedy and Professional Performance in a Pocket DMM
DIGITAL MULTIMETER DT4221, DT4222
CAT IV 300 V
CAT III 600 V
Regarding DMM Accuracy
■ Basic specifications (Accuracy guaranteed for 1 year)
DT4221
DT4222
600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt.
DC Voltage
AC Voltage
40 to 500 Hz
600.0 Ω to 60.00 MΩ, 6 ranges
Basic accuracy: ±0.9 % rdg. ±5 dgt.
C (capacitance)
N/A
1.000 μF to 10.00 mF, 5 ranges
Basic accuracy: ±1.9 % rdg. ±5 dgt.
Diode test
•Achieving a high level of safety in a compact body and lightweight design
•Test leads conveniently wrap around the back
•±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
•Low-pass filter (100 Hz/ 500 Hz) cuts high harmonics
•Current measurement function eliminated to enhance safety
• Broad -10 (14°F) to 50°C (122°F) operating temperature range
Voltage detection
Other functions
Display
Display refresh
rates
Power supply
Dimensions and
mass
Accessories
AC V measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges
Basic accuracy: ±0.1 % rdg. ±2 dgt.
Continuity threshold [ON]: 25 Ω or less (buzzer sound),
[OFF]: 245 Ω or more Response time: 0.5 ms or more
Open terminal voltage: 2.5 V or less,
Testing current 0.5 mA or less,
N/A
Threshold of forward voltage:
0.15 V to 1.5 V
80 V to 600 V AC
N/A
Filter function, Display value hold, Relative display, Auto-power save
Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on mea-
DMM
Tester s
N/A
Continuity check
DT4222
6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz
Basic accuracy: ±1.0 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance
Frequency
DT4221
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for
reference. Please refer to the individual catalogs for detailed accuracy information.
sured value, Frequency: 1 to 2 time/s )
LR03 alkaline batteries ×4, Continuous use: 40 hours (backlight OFF)
72 mm (2.83 in)W × 149 mm (5.87 in)H× 38 mm (1.50 in)D,
190 g (6.7 oz) (including batteries and holster)
Test lead DT4911 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline
battery ×1
Options for the DT4911 (DT4911 is a bundled accessory)
CAT IV 300V, CAT III 600V,
54cm (1.77ft) length
CONTACT PIN SET L4933 SMALL ALLIGATOR CLIP SET
Attaches to the tip of the
L4934
Test lead L9207-10/DT4911,
DC70V/AC33V
Attaches to the tip of the Test lead L920710/DT4911, CAT III 300V, CAT II 600V
Other options
Test leads
TEST LEAD DT4911
MAGNETIC STRAP
Z5004
CARRYING CASE
C0200
For the DT4220 series
79
DMM/Testers
Voltage measurement safety assured by non-contact testing
SAFETY HiTESTER 3258
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
■ Basic specifications (Accuracy guaranteed for 1 year)
Measurement parameter AC voltage (AC potential bridge)
Objects of measurement Insulated conductors (IV or CV equivalent, min. 100 mm² x-section), metal
conductors Note: Not usable on shielded conductors
Measurement range 420.0V/ 600V AC (Auto)
Measurement values True RMS
Max. rated voltage to earth 600V AC rms
Influence of adjacent wiring ±5% rdg. or less
Temperature characteristics 0.05 % rdg./ °C
Digital LCD, max. 4200 digit (zero suppress at 10 digits or less)
Display
Display refresh rate Approx. once every 0.6 seconds
2.4 s or less
Display response
Data hold function, auto-power off, low battery warning
Functions
CAT IV 600 V
Applicable electric cable types
Size: 100 mm2 or larger
insulated electric line
Power supply
100 mm2 (17 mm dia.) insulated cable
LR6 (AA) alkaline battery ×6, Continuous use: 14 hr (Power ON, no measurement), or
1-minute measurements for 1000 times, or 5-minute measurements for 200 times
Dimensions and mass 51mm (2.01in)W × 275mm (10.83in)H × 37.5mm (1.48in)D (one probe), 670g (23.6oz)
Instruction manual ×1, LR6 (AA) alkaline battery ×6, Soft carrying case ×1
Accessories
■ Basic accuracy.. Covered (unshielded) electric wires (Indoor PVC or equivalent, 100 mm or larger)
2
•Non-metallic contact for optimum safety
•Capture the voltage value of covered electric wires
•Also ideal for metallic busbars and terminals
•Optimized for 400 V AC circuits
Measurement
range
Accuracy guaranteed
range
420 V
30.0 - 420.0 V
380 - 480 V
481 - 600 V
600 V
Accuracy
40 - 66 Hz
±1.5% rdg. ±5 dgt.
±2.0% rdg. ±5 dgt.
±5.0% rdg. ±5 dgt.
66 - 400 Hz
±2.5% rdg. ±5 dgt.
Note: For insulated cables over 38 mm2 to less than 100 mm2, add 0.5% rdg. to measurement accuracy
■ Ensures safe measurements in the cubicle
Easily measure right through cable insulation
Safely measure around busbars
Safe Probe Heads
Also safe for metallic
conductors
Reliably safe, non-metallic resin heads
Easily Measure Current with a Clamp Sensor
DIGITAL HiTESTER 3255-50
CAT III 600 V
CAT II 1000 V
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
■ Basic specifications (Accuracy guaranteed for 1 year)
419.9 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5% rdg. ±4dgt.
DC Voltage
419.9 mV to 1000V, 5 ranges, Basic accuracy: ±1.2% rdg. ±4 dgt.
AC Voltage
50 to 500Hz
(Average rectified)
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±4 dgt.
Use with optional Clamp-on probes, Display the actual current value by scaling the sensor's
50 to 500Hz
0.2 VAC f.s. output. Basic accuracy: ±2.0 % rdg. ±4 dgt. plus clamp-on probe's accuracy
Continuity buzzer Threshold 50 Ω ± 40 Ω or less, Open terminal voltage: 3.4 V or less
Open terminal voltage: 3.4 V or less, Testing current 850 μA or less
Diode check
Auto power save Yes (Cancel possible)
Digital LCD, max. 4199 digits
Display
2.5 times/s
Sampling rate
Hold auto
Other functions
Protection rating IP 54 (EN 60529)
Protected against internal short-circuit with protective resistor (5 Ω currentProtection structure
limiting resistor) and built-in 0.44 A fuse (1000 VAC/10 kA interrupting capacity)
R03 (AAA) manganese battery ×2, Continuous use: 200 hours
Power supply
LR03 (AAA) alkaline battery ×2, Continuous use: 500 hours
Dimensions and mass 70 mm (2.76 in)W × 145 mm (5.71 in)H × 31 mm (1.22 in)D, 210g (7.4 oz) (including batteries)
Instruction manual ×1, R03 (AAA) Manganese batteries ×2 (for trial purposes
Accessories
only), Test lead L9207-10×1, Carrying case 9371 ×1
Resistance
AC Current
DMM
Tester s
•Built-in with current-limiting resistor and 1000 V withstanding fuse to
prevent short-circuit accidents
•Polarized terminal design prevents incorrect insertion of test leads
•Dust-proof and water-proof structure prevents dust and moisture
from entering the product (IP54)
•Measure AC load current with optional Clamp On Probes
Note: Use with the Conversion Adapter 9704, required for connecting Clamp On Probes
Options
CONVERSION
ADAPTER 9704
TEST LEAD
L9207-10
90 cm (2.95 ft) length
80
CARRYING
CASE 9371
CLAMP ON
PROBE 9010-50
Supplied accessory Input from 10 to 500 A,
40 Hz to 1 kHz for 0.2 V
AC output, BNC terminal
Receiving end: Female
BNC; Output end: Male
banana-plug *Not
Input from 20 to 1000 A, compatible with older
40 Hz to 1 kHz for 0.2 V generation Memory
AC output, BNC terminal Hicorders with banana
input terminals
CLAMP ON
PROBE 9132-50
Internal current-limiting resistor and fuse protect against operating
errors and catastrophic failures
In addition to internal circuitry to protect
against connection errors during use, the
current-limiting resistor and fast-blow fuse
protect against short-circuit conditions in the
unlikely event of catastrophic failure of the
tester circuit: short-circuit current is limited
until interruption by the fuse, rated for up to
10 kA.
*If voltage is applied to the test leads while in the resistance measurement mode, as long as it is within the
measurement category (CAT III 600 V, or CAT II 1000 V), protective components in the tester circuitry
prevent the fuse from opening.
DMM/Testers
Pencil-type DMM with LED light
PENCIL HiTESTER 3246-60
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
■ Basic specifications (Accuracy guaranteed for 1 year)
419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt.
DC Voltage
AC Voltage
4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt.
(Average rectified)
50 to 500 Hz
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2.0 % rdg. ±4 dgt.
Resistance
Continuity Buzzer Detection level 50 Ω ±40 Ω
Judges the right direction only, Open terminal voltage: 3.4 V or less,
Diode check
Testing current: 800 µA or less
Auto power save Available (cancel selectable)
Digital LCD, max. 4199 digits
Display
2.5 times/sec
Sampling rate
Coin type litium battery (CR2032) ×1, Continuous use: 150 hours (at DC V
Power supply
function), 30 hours (with light turned on for 10 seconds and off for 20 seconds
CAT IV 300 V
CAT III 600 V
Conceptual image
Removable test
pin sleeves
prevent shortcircuits
per cycle and in DC V function)
Dimensions and mass 30 mm (1.18 in)W × 182 mm (7.17 in)H × 26.5 mm (1.04 in)D, 80 g (2.8 oz)
Instruction manual ×1, Coin type litium battery (CR2032) ×1 (for trial
Accessories
purposes only), Sleeves (Red/ Black each 1)
•Test lead and main unit in a single body
•Overload protection to 600 V at resistance or continuity functions
•LED light brightly illuminates test points
Environmentally-friendly DMM
SOLAR HiTESTER 3245-60
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
■ Basic specifications (Accuracy guaranteed for 1 year)
419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt.
DC Voltage
AC Voltage
4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt.
(Average rectified)
50 to 500 Hz
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2.0 % rdg. ±4 dgt.
Resistance
Continuity Buzzer Detection level 50 Ω ±40 Ω, Diode check: Not available
"1000" digits display to approx. 50,000 lx
Light meter
Auto power save Available (cancel selectable)
Digital LCD, max. 4199 digits
Display
2.5 times/sec
Sampling rate
Rechargeable lithium-ion battery powered by solar source:
Main power supply
8 hours of use available on 3 hours of charging at 50,000 lx
CAT IV 300 V
CAT III 600 V
Removable test
pin sleeves
prevent shortcircuits
Secondary power Coin type lithium battery (CR2032) ×1,
Continuous use with secondary battery: 150 hours
supply
Dimensions and mass 60 mm (2.36 in)W × 135 mm (5.31 in)H × 23 mm (0.91 in)D, 140 g (4.9 oz)
Instruction manual ×1, Coin type lithium battery (CR2032) ×1 (for trial
Accessories
purposes only), Sleeves (Red/ Black each 1)
Compact ! Palm size body, Less than 1cm thin !
CARD HiTESTER 3244-60
CAT III 300 V
CAT II 600 V
Removable test
pin sleeves
prevent shortcircuits
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
■ Basic specifications (Accuracy guaranteed for 1 year)
419.9 mV to 500 V, 5 ranges, Basic accuracy: ±0.7 % rdg. ±4 dgt.
DC Voltage
AC Voltage
4.199 V to 500 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt.
(Average rectified)
50 to 500 Hz
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2.0 % rdg. ±4 dgt.
Resistance
Continuity Buzzer Detection level 50 Ω ±40 Ω, Diode check: Not available
Auto power save
Available (cancel selectable)
Display
Sampling rate
Power supply
Dimensions and mass
Digital LCD, max. 4199 digits
2.5 times/sec
Coin type lithium battery (CR2032) ×1, Continuous use: 150 hours
55 mm (2.17 in)W × 109 mm (4.29 in)H × 9.5 mm (0.37 in)D, 60 g (2.1 oz)
Instruction manual ×1, Carrying case ×1, Coin type lithium battery
(CR2032) ×1 (for trial purposes only), Sleeves (Red/ Black each 1)
Accessories
15 mm
Rugged external case protects
the DMM. Standard accessory.
Extra length for reaching
inside sockets
DMM
Tester s
•Hybrid power system incorporates both a solar-charged main battery
and a backup battery
•Pocket-sized CAT III (600 V) and CAT IV (300 V) conformance
(when test pin sleeves are attached)
•Neat test probe storage in the back of the unit
•Better contact test leads with 15 mm gold-plated tip pin
•Only 9.5 mm(0.37 in) thick and 60 g(2.1 oz) in weight
•Full auto-ranging function and automatic power saving function
•Overload protection to 500 V at resistance or continuity functions
*When used in CAT III environments,
test pin sleeves are required.
81
Analog Testers
Basic tester with improved safety features (20 kΩ/V)
HiTESTER 3030-10
Not CE Marked
CAT III 600 V
■ Basic specifications (Accuracy guaranteed for 1 year)
0.3 V (16.7 kΩ/V), 3/12/30/120/300/600 V (20 kΩ/V)
DC Voltage range
Accuracy: ±2.5 % f.s. Max. rated voltage: 600 V
12 V (9 kΩ/V) Accuracy: ±4 % f.s.
AC Voltage range 30/120/300/600 V (9 kΩ/V) Accuracy: ±2.5 % f.s.
Average rectifier effective value, Max. rated voltage: 600 V
60 µA/30 m/300 mA (300 mV internal voltage drop)
DC Current range
Accuracy: ±3 % f.s.
Battery check
0 to 3 kΩ (center scale 30 Ω), R × 1, R × 10, R × 100, R × 1 k
Accuracy: ±3 % of scale length
0.9 to 1.8 V, load resistance 10 Ω, Accuracy: ±6 % f.s.
Temperature scale
Note: The 3030-10 includes a temperature measurement scale, but because the optional Thermister
Temperature Probe 9021-01 has been discontinued, the scale is not available for new customers.
Resistance range
For resistance measurement range, R6P (AA) ×2 batteries
Power supply
Dimensions and mass 95 mm (3.74 in)W × 141 mm (5.55 in)H × 39 mm (1.54 in)D, 280 g (9.9 oz)
Test lead L9207-30 ×1, Spare fuse ×1, R6P (AA) manganese batteries ×2,
Accessories
Instruction manual ×1, Carrying case 9390 ×1
3030-10 Scale
*The L9207-30 and the 9390 are bundled
Options
•Drop proof design withstands drop onto a concrete floor from a
height of 1 meter
•LED check, Battery check support
TEST LEAD L9207-30
70 cm (2.30 ft) length
HIGH-VOLTAGE PROBE
9017
Up to 30kV DC, 1.4 m
CARRYING CASE 9390
(4.59 ft) length, Not CE
marked
Plastic type
For maintenance service (20 kΩ/V)
MULTI TESTER 3008
Not CE Marked
■ Basic specifications (Accuracy guaranteed for 1 year)
6/30/60/300/600V (20 kΩ/V)
DC Voltage range
Accuracy: ±2.5 % f.s.
6/30/150/300/600 V (10 kΩ/V)
AC Voltage range
Accuracy: ±2.5 % f.s. , Average rectifier effective value
0 to 10 kΩ (center scale 100 Ω), R × 1, R × 10, R × 100
Resistance range
Accuracy: ±3 % of scale length
For resistance measurement range, R6P (AA) × 2 batteries
Power supply
Circuit: Fuse-protected, internal circuit protection using the 10Ω resistance
Safety considerMeter: Diode-protected
ations
Dimensions and mass 94 mm (3.70 in)W × 134 mm (5.28 in)H × 56 mm (2.20 in)D, 350 g (12.3 oz)
Test lead 9060 ×1, Spare fuse ×1, R6P (AA) manganese battery ×2,
Accessories
Instruction manual ×1, Carrying case ×1
Analog Testers
*The 9060 is bundled
82
Options
•Supply current limiting resistance of 10 Ω restricts short circuit current
•High-power fuse protects up to 50,000 A
•Drop proof design withstands dropping onto a concrete floor from a
height of 1 meter
TEST LEAD 9060
85 cm (2.79 ft) length
Digital Insulation Testers
Quick response comparator offering reading stability in high-speed digital format
INSULATION TESTER IR4057-20
CAT III 600 V
Optional Test lead L9788-10
Bright LED lamp & comparator
indicator (green lamp)
■ Basic specifications (Accuracy guaranteed for 1 year)
Rated output voltage
50 VDC
125 VDC
250 VDC
Effective maximum
100 MΩ
250 MΩ
500 MΩ
indicated value
Accuracy
±4 % rdg.
±4 % rdg.
±4 % rdg.
1st effective mea0.200 - 10.00 0.200 - 25.0 0.200 - 50.0
suring range MΩ
Lower limit
0.05 MΩ
0.125 MΩ
0.25 MΩ
resistance
AC 600 V (10s)
Overload protection
DC voltage measurement
AC voltage measurement
Comparator function
Fail alert with Red LCD illuminator
• 5-range testing voltage of 50 V/100 MΩ to 1000 V/4000 MΩ
• Stable & high-speed digital readings, 0.3 second response time for
PASS/ FAIL decisions
• Drop proof onto concrete from 1m (3.28 feet)
• Bright LED, luminous LCD, test lead with bright LED lamp to illuminate
near hand (Option L9788-11 or L9788-10)
• Continuity check via 200 mA testing
• Built in AC/DC voltage meter, useful for testing solar power generation systems and electric vehicles
Low resistance
measurement
Display
Response time
Other functions
Power supply
500 VDC
1000 VDC
2000 MΩ
4000 MΩ
±4 % rdg.
0.200 - 500
±4 % rdg.
0.200 - 1000
0.5 MΩ
1 MΩ
AC 1200 V (10s)
4.2 V (0.001 V resolution) to 600 V (1 V resolution), 4 ranges,
Accuracy: ±1.3% rdg. ±4 dgt., Input resistance: 100 kΩ or higher
420 V (0.1 V resolution) / 600 V (1 V resolution), 2 ranges, 50/60 Hz,
Accuracy: ±2.3% rdg. ±8 dgt., Input resistance: 100 kΩ or higher, Average rectifier
For checking the continuity of ground wiring, 10 Ω (0.01 Ω resolution) to 1000 Ω
(1 Ω resolution), 3 ranges, Basic accuracy: ±3 % rdg. ±2 dgt., testing current 200
mA or more (at 6 Ω or less)
Semi-transmissive FSTN LCD with back lighting, bar-graph indicator
Approx. 0.3 second for PASS/FAIL decision (at Hioki's conditions)
Indicate MΩ measurement value after a lapse of one minute, Live circuit
indicator, Automatic electric discharge, Automatic DC/AC detection,
Comparator, Drop proof, Auto power save
LR6 (AA) alkaline batteries × 4, Continuous use: 20 hours (at Hioki’s conditions)
Number of measurements: 1000 times (at 5 s ON, 25 s OFF cycle, insulation measurement of lower limit resistance value to maintain nominal output voltage)
Dimensions and
mass
159 mm (6.26 in)W × 177 mm (6.97 in)H× 53 mm (2.09 in)D, 640 g (22.6 oz)
Accessories
Test lead L9787 ×1, Neck strap ×1, Instruction manual ×1, LR6 (AA)
alkaline batteries ×4
(including batteries, excluding test leads)
Our most popular model offering reading stability in medium-speed digital format
INSULATION TESTER IR4056-20
CAT III 600 V
Optional Test lead L9788-10
Bright LED lamp & comparator
indicator (green lamp)
■ Basic specifications (Accuracy guaranteed for 1 year)
Rated output voltage
50 VDC
125 VDC
250 VDC
Effective maximum
100 MΩ
250 MΩ
500 MΩ
indicated value
Accuracy
±4 % rdg.
±4 % rdg.
±4 % rdg.
1st effective mea0.200 - 10.00 0.200 - 25.0 0.200 - 50.0
suring range MΩ
Lower limit
0.05 MΩ
0.125 MΩ
0.25 MΩ
resistance
AC 600 V (10s)
Overload protection
DC voltage measurement
AC voltage measurement
Comparator function
Fail alert with Red LCD illuminator
Display
Response time
Other functions
Power supply
1000 VDC
4000 MΩ
±4 % rdg.
0.200 - 500
±4 % rdg.
0.200 - 1000
0.5 MΩ
1 MΩ
AC 1200 V (10s)
4.2 V (0.001 V resolution) to 600 V (1 V resolution), 4 ranges,
Accuracy: ±1.3 % rdg. ±4 dgt., Input resistance: 100 kΩ or higher
420 V (0.1 V resolution) / 600 V (1 V resolution), 2 ranges, 50/60 Hz,
Accuracy: ±2.3% rdg. ±8 dgt., Input resistance: 100 kΩ or higher, Average rectifier
For checking the continuity of ground wiring, 10 Ω (0.01 Ω resolution) to 1000 Ω
(1 Ω resolution), 3 ranges, Basic accuracy: ±3 % rdg. ±2 dgt., testing current 200
mA or more (at 6 Ω or less)
Semi-transmissive FSTN LCD with back lighting, bar-graph indicator
Approx. 0.8 second for PASS/FAIL decision (at Hioki's conditions)
Live circuit indicator, Automatic electric discharge, Automatic DC/AC
detection, Comparator, Drop proof, Auto power save
LR6 (AA) alkaline batteries ×4, Continuous use: 20 hours (at Hioki’s conditions)
Number of measurements: 1000 times (at 5 s ON, 25 s OFF cycle, insulation mea-
Field Measuring
Instruments
• 5-range testing voltage of 50 V/100 MΩ to 1000 V/4000 MΩ
• Stable & medium-speed digital readings, 0.8 response time of PASS/
FAIL decisions
• Drop proof onto concrete from 1m (3.28 feet)
• Bright LED, luminous LCD, test lead with bright LED lamp to illuminate
near hand (Option L9788-11 or L9788-10)
• Continuity check via 200 mA testing
• Built in AC/DC voltage meter, useful for testing solar power generation systems and electric vehicles
Low resistance
measurement
500 VDC
2000 MΩ
surement of lower limit resistance value to maintain nominal output voltage)
Dimensions and
mass
159 mm (6.26 in)W × 177 mm (6.97 in)H× 53 mm (2.09 in)D, 600 g (21.2 oz)
Accessories
Test lead L9787 ×1, Neck strap ×1, Instruction manual ×1, LR6 (AA)
alkaline batteries ×4
(including batteries, excluding test leads)
IR4057-20 / IR4056-20 INSULATION TESTER Common options
Exclusively for the L9787 *The L9787 is bundled
BREAKER PIN L9787-91
Bundled with Line/ Earth lead,
alligator clip, 1.2 m (3.94 ft) length
For checking breaker terminal,
Detachable for tip of the L9787, 48 mm
(1.89 in) length, φ 2.6 mm (0.10 in)
L9788 options
L9787 options
TEST LEAD L9787
Exclusively for the L9788-10/ L9788-11
TEST LEAD SET WITH REMOTE TEST LEAD WITH REMOTE
SWITCH L9788-11
SWITCH (RED) L9788-10
Bundled with Remote switch type test
lead L9788-10/ Earth lead, alligator
clip, 1.2 m (3.94 ft) length
Lighting LED lamp &
comparator indicator, 1.2 m
(3.94 ft) length
TIP PIN L9788-90
BREAKER PIN L9788-92
Spare parts for tip of the For checking breaker terminal,
L9788/ L9788-10, Tip
Detachable for tip of the L9788-10,
length 35 mm (1.38 in)
65 mm (2.56 in) length, φ 2.6 mm
(0.10 in)
Common Option
MAGNETIC ADAPTER
9804-02
Attached to the Earth side lead
tip, Tip diameter 11 mm (0.43 in)
83
Analog Insulation Testers
Reliable and Efficient Insulation Testing in the Field
ANALOG MΩ HiTESTER IR4018-20
CAT III 600 V
■ Basic specifications (Accuracy guaranteed for 1 year)
Rated output voltage 1000 V DC
Effective maximum
2000 MΩ
indicated value
Accuracy
±5 % of indicated value
1st effective
2 to 1000 MΩ
measuring range
Lower limit resistance 1 MΩ (measurement resistance value to maintain testing voltage)
Overload protection 1200 V AC (10 sec.)
AC voltage
measurement
0 to 600 V (50/60 Hz), ±5 % of maximum scale value accuracy,
500 kΩ or more input resistance
Other functions
Bright LED luminous scale, Drop proof (on concrete, 1 m/1 time),
Battery check, Live circuit check, Auto discharge
LR6 (AA) alkaline batteries ×4, Continuous use: 15 hours (no load)
159 mm (6.26 in)W × 177 mm (6.97 in)H × 53 mm (2.09 in)D, 610 g (21.5 oz),
Power supply
Dimensions and
mass
•Single range testing voltage of 1000 V
•Test insulation resistance up to 2000 MΩ
•Built tough to withstand a 1-meter drop onto a concrete floor
•Bright LED luminous scale
•Check for live circuits and battery status
•Integrated hard case for quick and easy storage without disconnecting the
leads
Accessories
(including battery, excluding test lead)
Test lead L9787 ×1, LR6 (AA) alkaline batteries ×4, Instruction manual ×1,
Shoulder strap ×1
Reliable and Efficient Insulation Testing in the Field
ANALOG MΩ HiTESTER IR4017-20
CAT III 600 V
■ Basic specifications (Accuracy guaranteed for 1 year)
Rated output voltage 500 V DC
Effective maximum
1000 MΩ
indicated value
Accuracy
±5 % of indicated value
1st effective
1 to 500 MΩ
measuring range
Lower limit resistance 0.5 MΩ (measurement resistance value to maintain testing voltage)
Overload protection 600 V AC (10 sec.)
AC voltage
measurement
0 to 600 V (50/60 Hz), ±5 % of maximum scale value accuracy,
500 kΩ or more input resistance
Other functions
Bright LED luminous scale, Drop proof (on concrete, 1 m/1 time),
Battery check, Live circuit check, Auto discharge
LR6 (AA) alkaline batteries ×4, Continuous use: 20 hours (no load)
159 mm (6.26 in)W × 177 mm (6.97 in)H × 53 mm (2.09 in)D, 610 g (21.5 oz),
Power supply
Dimensions and
mass
Field Measuring
Instruments
•Single range testing voltage of 500 V
•Test insulation resistance up to 1000 MΩ
•Built tough to withstand a 1-meter drop onto a concrete floor
•Bright LED luminous scale
•Check for live circuits and battery status
•Integrated hard case for quick and easy storage without disconnecting the
leads
Accessories
(including battery, excluding test lead)
Test lead L9787 ×1, LR6 (AA) alkaline batteries ×4, Instruction manual ×1,
Shoulder strap ×1
IR4018-20 to IR4016-20, 3490 ANALOG MΩ HiTESTER series Common options
Exclusively for the L9787 *The L9787 is bundled
Bundled with Line/ Earth
lead, alligator clip, 1.2 m
(3.94 ft) length
For checking breaker
terminal, Detachable for tip
of the L9787, 48 mm (1.89 in)
length, φ 2.6 mm (0.10 in)
TEST LEAD SET WITH
REMOTE SWITCH
L9788-11
Bundled with Remote
switch type test lead L978810/ Earth lead, alligator
clip, 1.2 m (3.94 ft) length
TEST LEAD WITH REMOTE
SWITCH (RED) L9788-10
Lighting LED lamp &
comparator indicator, 1.2 m
(3.94 ft) length
TIP PIN L9788-90
Spare parts for tip of
the L9788/ L978810, Tip length 35 mm
(1.38 in)
BREAKER PIN
L9788-92
For checking breaker
terminal, Detachable for
tip of the L9788-10, 65
mm (2.56 in) length, φ
2.6 mm (0.10 in)
Common option
BREAKER PIN L9787-91
L9788 options
L9787 options
84
TEST LEAD L9787
Exclusively for the L9788-10/ L9788-11
MAGNETIC ADAPTER
9804-02
Attached to the Earth
side lead tip, Tip
diameter 11 mm (0.43 in)
Analog Insulation Testers
Reliable and Efficient Insulation Testing in the Field
ANALOG MΩ HiTESTER IR4016-20
■ Basic specifications (Accuracy guaranteed for 1 year)
Rated output voltage 500 V DC
Effective maximum
100 MΩ
indicated value
Accuracy
±5 % of indicated value
1st effective
0.1 to 50 MΩ
measuring range
Lower limit resistance 0.5 MΩ (measurement resistance value to maintain testing voltage)
Overload protection 600 V AC (10 sec.)
CAT III 600 V
0 to 600 V (50/60 Hz), ±5 % of maximum scale value accuracy,
500 kΩ or more input resistance
Bright LED luminous scale, Drop proof (on concrete, 1 m/1 time),
Battery check, Live circuit check, Auto discharge
LR6 (AA) alkaline batteries ×4, Continuous use: 20 hours (no load)
159 mm (6.26 in)W × 177 mm (6.97 in)H × 53 mm (2.09 in)D, 610 g (21.5 oz),
AC voltage
measurement
Other functions
Power supply
Dimensions and
mass
(including battery, excluding test lead)
Test lead L9787 ×1, LR6 (AA) alkaline batteries ×4, Instruction manual ×1,
Shoulder strap ×1
Accessories
•Single range testing voltage of 500 V
•Test insulation resistance up to 100 MΩ
•Built tough to withstand a 1-meter drop onto a concrete floor
•Bright LED luminous scale
•Check for live circuits and battery status
•Integrated hard case for quick and easy storage without disconnecting the
leads
Insulation Testing in 3 Easy Steps: Flip the Cover, Select Range & Test
ANALOG MΩ HiTESTER 3490
■ Basic specifications (Accuracy guaranteed for 1 year)
250 V DC
500 V DC
Rated output voltage
Effective maximum
100 MΩ
100 MΩ
indicated value
±5 % of indicated
±5 % of indicated
Accuracy
value
value
1st effective
0.05 to 50 MΩ
0.05 to 50 MΩ
measuring range
0.25 MΩ
0.5 MΩ
Lower limit resistance
CAT III 600 V
1000 V DC
4000 MΩ
±5 % of indicated
value
2 to 1000 MΩ
1 MΩ
(Measurement resistance value to maintain testing voltage)
Overload protection
Low resistance
AC voltage
measurement
0 to 600 V (50/60 Hz), ±5 % of maximum scale value accuracy,
100 kΩ or more input resistance
Other functions
Bright LED luminous scale, Drop proof (on concrete, 1 m/1 time),
Battery check, Live circuit check, Auto discharge
LR6 (AA) alkaline batteries ×4, Continuous use: 20 hours (at 500 V range, no load)
159 mm (6.26 in)W × 177 mm (6.97 in)H × 53 mm (2.09 in)D, 610 g (21.5 oz),
Power supply
Dimensions and
mass
Accessories
(including battery, excluding test lead)
Test lead L9787 ×1, Instruction manual ×1, Shoulder strap ×1, LR6 (AA)
alkaline batteries ×4
Field Measuring
Instruments
•3-range testing voltage of 250/500 V (insulation resistance testing up
to 100 MΩ), and 1000 V (insulation testing up to 4000 MΩ)
•Continuity check at 3 Ω range via 200 mA testing
•Bright LED luminous scale
•Check for live circuits and battery status
1200 V AC (10 sec.)
3 Ω (at 200 mA testing current), ±0.09 Ω accuracy,
30 Ω (at 20 mA testing current), ±0.9 Ω accuracy,
Open-circuit voltage: 4.1 to 6.9 V
IR4018-20 to IR4016-20, 3490 ANALOG MΩ HiTESTER series Common options
Exclusively for the L9787 *The L9787 is bundled
Bundled with Line/ Earth
lead, alligator clip, 1.2 m
(3.94 ft) length
For checking breaker
terminal, Detachable for tip
of the L9787, 48 mm (1.89 in)
length, φ 2.6 mm (0.10 in)
TEST LEAD SET WITH
REMOTE SWITCH
L9788-11
Bundled with Remote
switch type test lead L978810/ Earth lead, alligator
clip, 1.2 m (3.94 ft) length
TEST LEAD WITH REMOTE
SWITCH (RED) L9788-10
Lighting LED lamp &
comparator indicator, 1.2 m
(3.94 ft) length
TIP PIN L9788-90
Spare parts for tip of
the L9788/ L978810, Tip length 35 mm
(1.38 in)
BREAKER PIN
L9788-92
For checking breaker
terminal, Detachable for
tip of the L9788-10, 65
mm (2.56 in) length, φ
2.6 mm (0.10 in)
Common option
BREAKER PIN L9787-91
L9788 options
L9787 options
TEST LEAD L9787
Exclusively for the L9788-10/ L9788-11
MAGNETIC ADAPTER
9804-02
Attached to the Earth
side lead tip, Tip
diameter 11 mm (0.43 in)
85
Digital Insulation Testers
Maximum 5kV Test Voltage - Up to 5TΩ of Insulated Resistance Testing
HIGH VOLTAGE INSULATION HiTESTER 3455
marked
■ Basic specifications (Accuracy guaranteed for 1 year)
Testing voltage
250 V DC
0.00MΩ - 9.99MΩ,
Measurement 9.0MΩ - 99.9MΩ,
resistance 90MΩ - 999MΩ,
organization 0.90GΩ - 9.99GΩ,
(Auto ranging)
9.0GΩ - 99.9GΩ,
90GΩ - 250GΩ
Accuracy
Resistance up to
testing V/100 nA
Short current
Other functions
Bundled Accessories
Options
Field Measuring
Instruments
86
TEST LEAD 9750-01
ALLIGATOR CLIP 9751-01
Red one, 3 m (9.84 ft) length
Red one
Black one, 3 m (9.84 ft) length
Black one
Blue one, 3 m (9.84 ft) length
Blue one
TEST LEAD 9750-02
TEST LEAD 9750-03
TEMPERATURE
SENSOR 9631-01
1 kV DC
2.5 kV DC
5 kV DC
0.00MΩ - 9.99MΩ,
9.0MΩ - 99.9MΩ,
90MΩ - 999MΩ,
0.90GΩ - 9.99GΩ,
9.0GΩ - 99.9GΩ,
90GΩ - 500GΩ
0.00MΩ - 9.99MΩ,
9.0MΩ - 99.9MΩ,
90MΩ - 999MΩ,
0.90GΩ - 9.99GΩ,
9.0GΩ - 99.9GΩ,
90GΩ - 999GΩ,
0.90TΩ - 1.00TΩ
0.00MΩ - 9.99MΩ,
9.0MΩ - 99.9MΩ,
90MΩ - 999MΩ,
0.90GΩ - 9.99GΩ,
9.0GΩ - 99.9GΩ,
90GΩ - 999GΩ,
0.90TΩ - 2.50TΩ
0.00MΩ - 9.99MΩ,
9.0MΩ - 99.9MΩ,
90MΩ - 999MΩ,
0.90GΩ - 9.99GΩ,
9.0GΩ - 99.9GΩ,
90GΩ - 999GΩ,
0.90TΩ - 5.00TΩ
±5% rdg. ±5dgt. ±5% rdg. ±5dgt. ±5% rdg. ±5dgt. ±5% rdg. ±5dgt. ±5% rdg. ±5dgt.
0.00MΩ - 2.50GΩ 0.00MΩ - 5.00GΩ 0.00MΩ - 10.0GΩ 0.00MΩ - 25.0GΩ 0.00MΩ - 50.0GΩ
Leak current
measurement
Voltage
measurement
Temperature
measurement
•Measure insulation of high-voltage equipment (such as transformers,
cables, and motors)
•Wide testing voltage range, up to 5.00 kV from 250 V DC
•Adjustable testing voltage in 25 V steps up to 1 kV, and 100 V steps
from 1 kV to 5 kV
•Wide measurement insulation range, up to 5 TΩ (at 5 kV testing voltage, 1 TΩ=10^12 Ω)
•Diagnose the insulation of various equipment with the built-in memory
for data storage
500 V DC
Display
Power supply
2 mA or less
2 mA or less
(used with the 9631-01/-05 optional sensor)
Insulation diagnose, Data memory, PC communication, Elapsed time display,
Clock, Averaging function, Data storage, Auto discharge, Auto power off, etc.
Digital LCD, max. 999 dgt. with backlight, Bar graph display
LR6 (AA) alkaline batteries ×6, Battery pack 9459, or AC adapter 9753
(100 - 240 VAC, output 12 VDC)
Continuous use : [LR6] 5 hr, [9459] 9 hr, (Occur 5 kV, +/- open terminal)
Dimensions and mass 260 mm (10.24 in)W × 251 mm (9.88 in)H × 120 mm (4.72 in)D, 2.8 kg (98.8 oz)
Test lead 9750-01 (red) ×1, Test lead 9750-02 (black) ×1, Test lead 9750-03
(blue) ×1, Alligator clip 9751-01 (red) ×1, Alligator clip 9751-02 (black) ×1,
Accessories
Alligator clip 9751-03 (blue) ×1, Instruction manual ×1, LR6 (AA) alkaline
batteries ×6, USB cable ×1, PC application software (CD-R) ×1
TEST LEAD 9750-11
Red one, 10 m (32.81 ft) length
2 mA or less
age is generated)
ALLIGATOR CLIP 9751-03
Molded type, 1 m (3.28 ft) length, Molded type, 30 mm (1.18 in) length, TEST LEAD 9750-12
-40 to 180 °C, 100 sec response
-40 to 180 °C, 100 sec response time, Black one, 10 m (32.81 ft) length
time, sensor part dimensions φ 6 sensor part dimensions φ 6 × 28 mm TEST LEAD 9750-13
Blue one, 10 m (32.81 ft) length
× 28 mm (φ 0.24 in × 1.10 in)
(φ 0.24 in × 1.10 in)
2 mA or less
±50 V to ±1.00 kV DC, 50 V to 750 V AC (50/60 Hz),
Accuracy: ±5 % rdg. ±5 dgt. , Input resistance: Approx. 10 MΩ
-10.0 ˚C to 70.0 ˚C, Accuracy: ±1.5 ˚C, 0.0 ˚C40.0 ˚C, Accuracy: ±1.0˚C
ALLIGATOR CLIP 9751-02
TEMPERATURE SENSOR
9631-05
2 mA or less
1.00 nA to 1.20 mA, 6 ranges (current measurement that occurs when test volt-
BATTERY PACK
9459
NiMH, Charges while
installed in the main unit
AC ADAPTER 9753
100 to 240 V AC
Clamp Meters/Leak
Easily read measured values from all heights with the adjustable display
CLAMP ON LEAK HiTESTER 3293-50
CAT III 300 V
Slim core opens wide
for easier clamping.
Display rotates freely through 180°
to keep measurements in view.
180° Open and Close system
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
30.00 m/ 300.0 m/ 6.000/ 60.00/ 600.0/ 1000 A, 6 ranges, 45 Hz to 400
Hz, True RMS
AC Current
Basic accuracy: ±1.5% rdg. ±5dgt. (50/60 Hz, filter ON)
N/A
AC Voltage
N/A
Frequency
2.8 or less (1.68 or less at 1000 A range)
Crest factor
Cut off frequency 180 Hz at filter ON (−3 dB)
Filter function
N/A
Output function
Flip-open mechanism (but still retaining proper orientation of display),
Other functions
Backlight, Maximum value display, Data hold, Auto power off
Digital LCD, max. 6000 dgt., 91 segments
Display
Display refresh rate: 1.1 sec or less
Coin type lithium battery (CR2032) ×1, Continuous use 18 hours
Power supply
Core jaw dia.
φ 24 mm (0.94 in)
Dimensions and
mass
50 mm (1.97 in) W × 130 mm (5.12 in) H × 26 mm (1.02 in) D,
135 g (4.8 oz)
Accessories
Carrying case 9757 ×1, Strap ×1, Instruction manual ×1, Coin type
lithium battery (CR2032, for trial purposes only) ×1
•Measure for leakage current and load all with the same device
•Innovative flip clamp design
•Flip display to see measurement readings from any angle
•1mA to 1000A accuracy guaranteed, 6 ranges and bar graph display
•Measure and display only the leakage current of commercial frequency
components using the filter function
*The 9757 is bundled
Options
CARRYING CASE 9757
Soft type
Easily monitor leak current fluctuations
CLAMP ON LEAK HiTESTER 3283
CAT III 300 V
Insulated conductor
Accessories
Carrying case 9399 ×1, Hand strap ×1, Stacked manganese battery
(6F22) ×1, Instruction manual ×1
Field Measuring
Instruments
•Measure leak current using highly sensitive 10μA resolution (at 10.00 mA
range)
•Indicate 50/60 Hz leak current components with the filtering function
•Monitor leak current conditions in combination with a Memory HiCorder
(monitor output)
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
10.00m/ 100.0m/ 1.000/ 10.00/ 200.0 A, 5 ranges, (40 Hz to 2 kHz, True
AC Current
RMS), Basic accuracy: ±1.0 % rdg. ±5 dgt.
N/A
AC Voltage
30.0 Hz to 1000 Hz, 2 ranges, Basic accuracy: ±0.3 % rdg. ±1 dgt.
Frequency
2.5 or less (1.5 at 200 A range)
Crest factor
Cut off frequency at filter ON: 180 Hz (-3dB)
Filter function
REC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 A range),
response time: less than 200 ms.
Output
MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200 A range), 5 Hz to
15 kHz frequency bandwidth (-3 dB)
Max./ Min./ Average value record, Data hold, Auto power off
Other functions
LCD, max. 2000 dgt., Display refresh rate: 4 times/s (FAST), 1 time/3 s
Display
(SLOW), 4 times/s (bar graph)
6F22 (Stacked manganese battery) ×1, Continuous use: 40 hours, or AC
Power supply
adapter 9445-02/-03
φ 40 mm (1.57 in)
Core jaw dia.
62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D,
Dimensions and
400 g (14.1 oz)
mass
*The 9399 is bundled
Options
AC ADAPTER
9445-02
AC ADAPTER
9445-03
For USA, 100 to 240 For EU, 100 to 240 V
V AC, 9 V/ 1 A
AC, 9 V/ 1 A
OUTPUT CORD 9094
CONVERSION
3.5 mm (0.14 in) dia. mini
ADAPTER 9199
plug to banana, 1.5 m (4.92 ft) Catch side banana, output
length, Not CE marked
BNC terminal
CARRYING CASE
9399
87
Clamp Meters
Easily read measured values from all heights with the adjustable display
CLAMP ON HiTESTER 3291-50
CAT IV 300 V
CAT III 600 V
Slim core opens wide
for easier clamping.
Display rotates freely through 180°
to keep measurements in view.
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
60.00/ 600.0/ 1000 A, 3 ranges, 45 Hz to 400 Hz, True RMS
AC Current
Basic accuracy: ±1.5 % rdg. ±5 dgt. (50/60 Hz, filter ON)
N/A
AC Voltage
N/A
Frequency
2.8 or less (1.68 or less at 1000 A range)
Crest factor
Cut off frequency 180 Hz at filter ON (−3 dB)
Filter function
N/A
Output function
Flip-open mechanism (but still retaining proper orientation of display),
Other functions
Back light, Maximum value display, Data hold, Auto power off
Power supply
Digital LCD, max. 6000 dgt., 91 segments
Display refresh rate: 1.1 sec or less
Coin type lithium battery (CR2032) ×1, Continuous use 20 hours
Core jaw dia.
φ 30 mm (1.18 in)
Dimensions and
mass
50 mm (1.97 in) W × 136 mm (5.35 in) H × 26 mm (1.02 in) D, 115 g
(4.1 oz)
Accessories
Carrying case 9757 ×1, Strap ×1, Instruction manual ×1, Coin type
lithium battery (CR2032, for trial purposes only) ×1
Display
180° Open and Close system
*The 9757 is bundled
Options
•Innovative flip clamp design
•Flip display to see measurement readings from any angle
•Max. 1000A, 3 ranges, Bar graph display
CARRYING CASE 9757
Soft type
All the Functions You Need for Measurement at DC or 1Hz and Up
CLAMP ON AC/DC HiTESTER 3290, 3290-10
CAT III 600 V
For Clamp Sensor
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
3290
Measurement
modes
DC, AC+DC (True RMS), AC (True
RMS/ Average rectified)
Field Measuring
Instruments
•Choice of three sensors
Measure up to 100 A, 200 A, or 2000 A rated current
•Correctly measure for inverter current with AC+DC mode and True RMS rectification
•Choice of output (Simultaneous output): Effective value, waveform, frequency,
and integral value output
•Choice of response time with three steps
•Model 3290-10 supports current integration and operating ratio measurements
Current measurement
Other options
88
CAT III 600 V
CAT III 600 V
CAT III 600 V
CLAMP ON AC/DC SENSOR
CT9691
CLAMP ON AC/DC SENSOR
CT9692
CLAMP ON AC/DC SENSOR
CT9693
DC to 10 kHz (-3dB), 100 A, 2 m
(6.56 ft) length
DC to 20 kHz (-3dB), 200 A, 2 m
(6.56 ft) length
DC to 15 kHz (-3dB), 2000 A, 2 m
(6.56 ft) length
OUTPUT CORD
9094
CONVERSION
ADAPTER 9199
3.5 mm (0.14 in) dia.
Female banana terminals to CARRYING CASE
mini plug to banana, 1.5 BNC plug (output), use to
9400
m (4.92 ft) length, Not
connect to BNC terminal on Includes compartment
CE markde
Input Module
for options
AC ADAPTER
9445-02
AC ADAPTER
9445-03
For USA, 100 to 240 For EU, 100 to 240 V
V AC, 9 V/ 1 A
AC, 9 V/ 1 A
RMS)
Peak value display Absolute value (of waveform peak)
Polarities independently (±peak value
Separate AC/DC output Separate constituent element of AC, DC
Current waveform or true RMS
Output
value (2 V / setting range), Frequency
(terminal 1)
value (1 VDC / setting range)
Rms current/Low-battery warning
Output
switch
(terminal 2)
N/A
Integral current
N/A
measurement
Rate measurement N/A
N/A
Timer settings
Sensor is sold separately
3290-10
DC, AC+DC (True RMS), AC (True
of waveform, in DC mode)
Current waveform or true RMS
value (2 V / setting range)
Current integral value (1 VDC / setting range)
±, +, - integral, average value
Operating time rate, total measurement time
99 h, 59 min. (for repeated up to 20 times)
Peak, integral value, operating time
N/A
Data storage
rate, or other
20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
Basic accuracy at
20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
DC current
200.0/ 2000A (using the CT9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A
Basic accuracy at 20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
AC current
200.0/ 2000A (using the CT9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A
(45 to 66 Hz)
Voltage measurement N/A
Frequency
1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.
measurement
2.5 or less, or rated peak value of sensor
Crest factor
DC, or 1 Hz to 1 kHz (accuracy guaranteed range)
Frequency
At monitor output: based on the using sensor
characteristics
Switching measurement response speed, Turning the filter on/off (fc=550 Hz)
Other functions
LR6 (AA) alkaline batteries ×4, Continuous use : 22 hr, or AC adapter 9445-02/
Power supply
-03 (The 3290-10 only: +8.4 to 15.6 V DC external power supply possible)
Dimensions and mass 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)
Strap ×1, LR6 (AA) alkaline batteries × 4, Instruction manual ×1
Accessories
Clamp Meters
Compact & easy, one-touch maintenance on all types of AC/DC equipment
CLAMP ON AC/DC HiTESTER 3288, 3288-20
CAT III 600 V (Current)
CAT III 300 V (Voltage)
CAT II 600 V (Voltage)
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
3288
100.0/ 1000 A, Basic accuracy: ±1.5 % rdg. ±5 dgt.
AC Current
100.0/ 1000 A, (10 Hz to 500 Hz,
Average rectified),
Basic accuracy: ±1.5 % rdg. ±5 dgt.
DC Voltage
419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt.
AC Voltage
4.199 V to 600 V, 4 ranges,
4.199 V to 600 V, 4 ranges,
Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to
500 Hz, Average rectified)
500 Hz, True RMS)
Resistance
Crest factor
Other functions
Display
3288
3288-20
100.0/ 1000 A, (10 Hz to 500 Hz, True
RMS),
Basic accuracy: ±1.5 % rdg. ±5 dgt.
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.
N/A
3 or less (2 at 1000 A range, 1.5 at Voltage)
Continuity: (50 Ω ±40 Ω) or less buzzer sounds, Data hold, Auto power save, Auto zero (DC A)
LCD, max. 4199 dgt., Display refresh rate: 2.5 times/s
Coin type lithium battery (CR2032) Coin type lithium battery (CR2032)
Power supply
×1, Continuous use 60 hours
×1, Continuous use 35 hours
φ 35 mm (1.38 in)
Core jaw dia.
Dimensions and mass 57 mm (2.24 in)W × 180 mm (7.09 in)H × 16 mm (0.63 in)D, 150 g (5.3 oz)
Instruction manual ×1, Test lead L9208 ×1, Carrying case 9398 ×1
Accessories
Accessories
•Model 3288-20: True RMS
•Use the 3288 for high current measurements such as UPS emergency
batteries and train motors
•Voltage, resistance, and continuity check functions
3288-20
DC Current
Note: Bundled accessories
CARRYING CASE
9398
TEST LEAD L9208
70 cm (2.30 ft) length
Compact & easy, one-touch maintenance on all types of AC/DC equipment
CLAMP ON AC/DC HiTESTER 3287
CAT III 600 V (Current)
CAT III 300 V (Voltage)
CAT II 600 V (Voltage)
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
10.00/ 100.0 A, Basic accuracy: ±1.5 % rdg. ±5 dgt.
DC Current
10.00/ 100.0 A (10 Hz to 1 kHz, True RMS)
AC Current
Basic accuracy: ±1.5 % rdg. ±5 dgt.
419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt.
DC Voltage
4.199 V to 600 V, 4 ranges (30 to 500 Hz, True RMS)
AC Voltage
Basic accuracy: ±2.3 % rdg. ±8 dgt.
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt
Resistance
2.5 or less (150 A, 100 V max.)
Crest factor
Continuity: (50 Ω ±40 Ω) or less buzzer sounds, Data hold, Auto power save, Auto zero (DC A)
Other functions
LCD, max. 4199 dgt., Display refresh rate: 2.5 times/s
Display
Coin type lithium battery (CR2032) ×1, Continuous use 25 hours
Power supply
φ 35 mm (1.38 in)
Core jaw dia.
Dimensions and mass 57 mm (2.24 in)W × 180 mm (7.09 in)H × 16 mm (0.63 in)D, 170 g (6.0 oz)
Instruction manual ×1, Test lead L9208 ×1, Carrying case 9398 ×1
Accessories
Accessories
•Model 3287: True RMS
•Accurately measure even small currents with 10 A range
•Voltage, resistance, and continuity check functions
Note: Bundled accessories
CARRYING CASE
9398
TEST LEAD L9208
70 cm (2.30 ft) length
CLAMP ON POWER HiTESTER 3286-20
CAT III 600 V
•Measure single-phase 600kW lines and up to the 20th harmonic level
•Active/ reactive/ apparent power, Power factor, Phase detection, Frequency,
Harmonic waveform value, or Waveform peak value
•Simple checking of three-phase lines (balanced with no distortion)
Accessories
Note: The 3286-20's three-phase power measurement method calculates and displays the power
values for a sine wave input at 50/60 Hz, assuming it is balanced and there is no distortion.
Accurate measurement is not possible on a three-phase line if it is not balanced, for example
when controlled by an inverter or thyristor.
Since there is no integration function, it is not possible to measure total energy consumed (Wh).
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
Measurement line Single-phase, Three-phase (balanced with no distortion)
Voltage, Current, Voltage/current peak, Active/ reactive/ apparent power, Power facMeasurement
tor, Phase angle, Reactivity, Frequency, Voltage/current harmonic levels
items
150.0 V to 600 V, 3 ranges
Voltage ranges
30 - 1kHz
Basic accuracy: ±1.0 % rdg. ±3 dgt. (at 45 - 66 Hz, True RMS)
20.00 A to 1000 A, 3 ranges
Current ranges
45 - 1kHz
Basic accuracy: ±1.3 % rdg. ±3 dgt. (at 45 - 66 Hz, True RMS)
[Single phase] 3.000 kW to 600.0 kW
Power ranges
Basic accuracy: ±2.3 % rdg. ±5 dgt. (at 50/60 Hz, Power factor = 1)
80 - 600 V
[Balanced three phase] 6.000 kW to 1200 kW
1 - 1000 A
Basic accuracy: ±3.0 % rdg. ±10 dgt. (at 50/60 Hz, Power factor = 1)
Voltage/current harmonic levels up to 20th, Content factor, Total harmonic distortion ratio
Harmonic levels
[Phase angle] Forward 90.0 ° to 0 to delay 90.0 °
[Power factor] Forward 0 to 1.000 to delay 0
[Frequency] 30.0 Hz to 1000 Hz
Other functions
Waveform peak, Phase detection, Max. / Min. value record, Data hold, Auto
power off, RS-232C output (Options are discontinued, so cannot use RS-232C)
LCD, Max. 6000 digits, Display refresh rate: 1 time/s (Normal) 1 time/3s
Display
(Slow), 1 time/2s (Harmonic level)
Stacked alkaline battery (6LR61, 6LF22) ×1, Continuous use: 25 hours
Power supply
φ 55 mm (2.17 in) or 80 mm (3.15 in) × 20 mm (0.79 in) bus-bar
Core jaw dia.
Dimensions and mass 100 mm (3.94 in)W × 287 mm (11.3 in)H × 39 mm (1.54 in)D, 650 g (22.9 oz)
Carrying case 9245 ×1, Voltage cord L9635-01 ×1, Hand strap ×1,
Accessories
Stacked alkaline battery (6LF22) ×1, Instruction manual ×1
Field Measuring
Instruments
Functionality and Safety Packed into a Handheld Unit
Note: Bundled accessories
VOLTAGE CORD L9635-01
Detachable alligator clip, 3 m (9.84 ft)
length
89
Clamp Meters
AC/DC current measurements up to 2000 A
CLAMP ON AC/DC HiTESTER 3285, 3285-20
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
3285
DC Current
CAT III 600 V
AC Current
DC Voltage
AC Voltage
30.00 V to 600 V, 3 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.
Crest factor
2.5 or less (1.42 at 2000 A, 1.7 at 600 V)
DC, or AC 1 V/ f.s., Level output,
Waveform output: DC to 15 kHz
N/A
bandwidth (±3dB)
1000 Ω/ 10.00 kΩ, Basic accuracy:
N/A
±1.5 % rdg. ±5 dgt., Continuity:
Beep sound at 30 Ω or less
1.00 Hz to 1000 Hz, Basic accuracy: ±0.3 % rdg. ±1 dgt.
AC+DC mode, Maximum/ Minimum/ Average value record function,
Data hold, Peak hold, Auto power off, Auto zero
Display refresh rate: 4 times/s (FAST), 1 time/3s (SLOW), 4 times/s (bar graph)
6F22 (Stacked manganese battery) 6F22 (Stacked manganese battery)
×1, Continuous use: 25 hours, or
×1, Continuous use: 20 hours,
AC adapter 9445-02/-03
Cannot use with the AC adapter
φ 55 mm (2.17 in)
62 mm (2.44 in) W × 260 mm (10.24 in) H × 39 mm (1.54 in) D,
540 g (19.0 oz)
Monitor, Analog
output
Resistance,
Continuity check
Frequency
3285-20
3285
Other functions
•Analog output for current measuring level, current measuring waveform,
or frequency measuring level.
•Peak hold function displays the crest value peak current up to 2840 A
•AC+DC mode enables measurement of the RMS value of full- or halfwave rectified waveforms
•Model 3285-20 adds resistance and continuity check functions
3285-20
200.0/ 2000 A, Basic accuracy: ±1.3 % rdg. ±3 dgt.
200.0/ 2000 A, (10 Hz to 1 kHz, True RMS),
Basic accuracy: ±1.3 % rdg. ±3 dgt.
30.00 V to 600 V, 3 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.
Display
Power supply
Core jaw dia.
Dimensions and
mass
Accessories
(10 to 1 kHz, True RMS)
Test lead L9207-10 ×1, Carrying case 9345 ×1, Hand strap ×1, 6F22
(Stacked manganese battery) ×1, Instruction manual ×1
*Test lead and Carrying case are bundled accessories
Options
TEST LEAD L9207-10 AC ADAPTER
90 cm (2.95 ft) length, for
9445-02
DT4280s/4250s, 3256s,
3281s, or other
For USA, 100 to 240
V AC, 9 V/ 1 A
AC ADAPTER
9445-03
For EU, 100 to 240 V
AC, 9 V/ 1 A
OUTPUT CORD 9094
3.5 mm (0.14 in) dia. mini
plug to banana, 1.5 m (4.92 ft)
length, Not CE marked
CONVERSION
ADAPTER 9199
Female banana terminals to
BNC plug (output), use to connect to BNC terminal on Input
Module
CARRYING
CASE 9345
Analysis for DC to distorted waves
CLAMP ON AC/DC HiTESTER 3284
CAT III 600 V
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
20.00/ 200.0 A, Basic accuracy: ±1.3 % rdg. ±3 dgt.
DC Current
20.00/ 200.0 A, (10 Hz to 2 kHz, True RMS),
AC Current
Basic accuracy: ±1.3 % rdg. ±3 dgt.
30.00 V to 600 V, 3 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.
DC Voltage
Field Measuring
Instruments
AC Voltage
30.00 V to 600 V, 3 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (10 to 1 kHz,
Crest factor
Monitor, Analog
output
2.5 or less (1.5 at 200 A, 1.7 at 600 V)
DC, or AC 1 V/ f.s., Level output, Waveform output: DC to 20 kHz
bandwidth (±3dB)
Resistance,
Continuity check
Frequency
Other functions
Display
Power supply
•Analog output for current measuring level, current measuring waveform,
or frequency measuring level.
•Peak hold function displays the crest value of the inrush current occurring when electrical equipment starts
•AC+DC mode enables measurement of the RMS value of full- or halfwave rectified waveforms
Core jaw dia.
Dimensions and
mass
Accessories
True RMS)
N/A
1.00 Hz to 1000 Hz, Basic accuracy: ±0.3 % rdg. ±1 dgt.
AC+DC mode, Maximum/ Minimum/ Average value record function,
Data hold, Peak hold, Auto power off, Auto zero
Display refresh rate: 4 times/s (FAST), 1 time/3s (SLOW), 4 times/s (bar graph)
6F22 (Stacked manganese battery) ×1, Continuous use: 25 hours, or AC
adapter 9445-02/-03
φ 33 mm (1.30 in)
62 mm (2.44 in) W × 230 mm (9.06 in) H × 39 mm (1.54 in) D, 460 g
(16.2 oz)
Test lead L9207-10 ×1, Carrying case 9399 ×1, Hand strap ×1, 6F22
(Stacked manganese battery) ×1, Instruction manual ×1
*Test lead and Carrying case are bundled accessories
Options
TEST LEAD L9207-10 AC ADAPTER
90 cm (2.95 ft) length, for
9445-02
DT4280s/4250s, 3256s,
3281s, or other
90
For USA, 100 to 240
V AC, 9 V/ 1 A
AC ADAPTER
9445-03
For EU, 100 to 240 V
AC, 9 V/ 1 A
OUTPUT CORD 9094
3.5 mm (0.14 in) dia. mini
plug to banana, 1.5 m (4.92 ft)
length, Not CE marked
CONVERSION
ADAPTER 9199
Female banana terminals to
BNC plug (output), use to connect to BNC terminal on Input
Module
CARRYING
CASE 9399
Clamp Meters
True RMS multi-functional clamp testers for distorted waveforms
DIGITAL CLAMP ON HiTESTER 3281, 3282
marked
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
3281
AC Current
AC Voltage
Crest factor
Monitor, Analog
output
Frequency
Resistance,
Continuity check
3281
CAT IV 600 V
Power supply
Core jaw dia.
Dimensions and
mass
62 mm (2.44 in) W × 218 mm (8.58 in) H 62 mm (2.44 in) W × 230 mm (9.06 in) H
× 39 mm (1.54 in) D, 350 g (12.3 oz)
× 39 mm (1.54 in) D, 400 g (14.1 oz)
Accessories
Test lead L9207-10 ×1, Instruction manual ×1, Carrying case 9399 ×1,
Hand strap ×1, Stacked manganese battery (6F22) ×1
Display
3282
•Choose from two models to measure current up to 600A or 1000A
•Multi-functional testing of AC current, voltage, frequency, resistance
and wave peak value
•Non-fuse type protects up to 600 V AC
N/A
30.0 Hz to 1000 Hz, Basic accuracy: ±0.3 % rdg. ±1 dgt.
1000 Ω/ 10.00 kΩ, Basic accuracy: ±1.5 % rdg. ±5 dgt.,
Continuity: Beep sound at 30 Ω or less
Current wave peak value, Voltage wave peak value, Distortion check
(Crest factor 1.00 to 5.00), Maximum/ Minimum/ Average value record
function, Data hold, Auto power off
LCD, Max. 3000 dgt., Display refresh rate: 4 times/s (FAST), 1 time/3s
(SLOW), 4 times/s (bar graph)
Stacked manganese battery (6F22) ×1, Continuous use: 45 hours
φ 33 mm (1.30 in)
φ 46 mm (1.81 in)
Other functions
Current : CAT III 600 V
Voltage : CAT IV 600 V
3282
30.00 to 600 A, 3 ranges (40 Hz to 1 kHz, 30.00 to 1000 A, 3 ranges (40 Hz to 1 kHz,
True RMS),
True RMS),
Basic accuracy: ±1.0 % rdg. ±5 dgt.
Basic accuracy: ±1.0 % rdg. ±5 dgt.
300.0/ 600 V, (40 Hz to 1 kHz, True RMS)
Basic accuracy: ±1.0 % rdg. ±3 dgt.
2.5 or less (1.7 at 600 A, 1.7 at 600 V) 2.5 or less (1.7 at 1000 A, 1.7 at 600 V)
Note: The 3281/3282 includes a temperature measurement function, but because the optional Thermister
Temperature Probe 9462 has been discontinued, the function is not available for new customers.
*Test lead and Carrying case are bundled accessories
Accessories
TEST LEAD L9207-10
90 cm (2.95 ft) length, for
DT4280s/4250s, 3256s,
3281s, or other
CARRYING
CASE 9399
Easy clamping in narrow locations with 16 mm slim body
CLAMP ON HiTESTER 3280-10, 3280-20
CAT III 600 V (Current)
CAT III 300 V (Voltage)
CAT II 600 V (Voltage)
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
3280-10
AC Current
DC Voltage
Accessories
Instruction manual ×1, Carrying case 9398 ×1, Test lead L9208 ×1
Other functions
Display
3280-20
•Model 3280-10: Measure the fundamental waveform component using
the average rectified method
•Model 3280-20: Measure even harmonic waveform components using
the True RMS method
•Wide range of Max. 1000 A, drop proof design withstands drop from a
height of 1 meter
True RMS),
Core jaw dia.
Dimensions and
mass
Crest factor
Resistance
3280-10
Average rectified),
Basic accuracy: ±2.3 % rdg. ±8 dgt.
Basic accuracy: ±2.3 % rdg. ±8 dgt.
N/A
2.5 or less (1.5 at f.s. of range)
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt.
Continuity: (50 Ω ±40 Ω) or less buzzer sounds, Data hold, Auto power
save, Drop proof design withstands dropping onto a concrete floor
from a height of 1 meter
LCD, max. 4199 dgt., Display refresh rate: 2.5 times/s, 1 time/3 seconds
Coin type lithium battery (CR2032) Coin type lithium battery (CR2032)
×1, Continuous use 150 hours
×1, Continuous use 50 hours
φ 33 mm (1.30 in)
57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D,
100 g (3.5 oz)
Power supply
Field Measuring
Instruments
AC Voltage
3280-20
41.99 to 1000 A, 3 ranges (50 to 60 Hz, 41.99 to 1000 A, 3 ranges (40 Hz to 1 kHz,
Average rectified),
True RMS),
Basic accuracy: ±1.5 % rdg. ±5 dgt.
Basic accuracy: ±1.5 % rdg. ±5 dgt.
419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt.
4.199 V to 600 V, 4 ranges (50 to 500 Hz, 4.199 V to 600 V, 4 ranges (50 to 500 Hz,
*Test lead and Carrying case are bundled accessories
Accessories
TEST LEAD L9208
70 cm (2.30 ft) length, for
the 3280, 3287/88s
CARRYING
CASE 9398
For the 3280,
3287/88s
91
Earth Testers
Easy pole earth resistance measurement with super slim jaw
CLAMP ON EARTH TESTER FT6380, FT6381
■ Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
Instrument has two cores for voltage injection and current measurement.
From the defined voltage and measured current, the total circuit loop
Measurement
resistance is calculated
Principle
CAT IV 600 V
Note: For multi grounded systems only. In a multi-grounded system, the larger the
number of grounding poles, the more accurate the measured value.
Earthing resistance
FT6381 only
AC Current measurement
0.20 Ω (0.01 Ω resolution) to 1600 Ω (20 Ω resolution), 10 ranges, Zero suppression:
Less than 0.02 Ω,
Accuracy: ±1.5 % rdg. ±0.02 Ω
20.00 mA (0.01 mA resolution) to 60.0 A (0.1 A resolution), 5 ranges, Zero suppression:
Less than 0.05 mA,
Accuracy: ±2.0 % rdg. ±0.05 mA (30 Hz to 400 Hz, True RMS), Crest factor 5.0 or less
(for the 60 A range, 1.7 or less)
Max. allowable
100 A AC continuous, AC 200 A for 2 minutes or shorter (at 50/60 Hz, requires
derating at frequency)
input
Max. rated voltage
600 V AC CAT IV
to earth
Memory function 2000 data
For resistance measurement and current measurement, Beeps when measured
Alarm function
value is less than or greater than threshold
Data hold, Backlight, Filter, Auto power save
Other functions
Digital LCD, max. 2000 dgt., Display refresh rate: 500 ms (2 times/s)
Display
Waterproof and
IP40 (EN60529) with clamp sensor closed
dustproof
Model FT6381 only: Bluetooth® v2.1+EDR, Compatibility for Smartphone
Communication
/ Tablet, Displays measured values on the screen of an Android™ handset
interface
via Bluetooth®, Applicable OS: Android™ 2.1 or later
LR6 (AA) alkaline battery ×2, Max. rated power: 450 mVA, Continuous use
Power supply
: 35 hr (in-house testing conditions)
φ 32 mm (1.26 in)
Core jaw dia.
Dimensions and mass 73 mm (2.87 in)W × 218 mm (8.58 in)H × 43 mm (1.69 in)D, 620 g (21.9 oz)
Carrying case ×1, Resistance check loop (1 Ω, 25 Ω) ×1, Strap ×1, LR06 (AA)
Accessories
alkaline battery ×2, Instruction manual ×1
•Earth resistance measurement for multi-grounded systems
•Measure leak current with absolute certainty with highly sensitive 0.01 mA
resolution (at 20.00 mA range)
•Measure load current up to 60.0 A range
•Clamp at the narrowest point
•Data transfer to Android™ phones using Bluetooth® wireless technology
•Real time data transfer, automatic report generation on Android™ phone
Note) The application supports Android™ OS 2.1 or later, but proper operation is not guaranteed
on all Android™ handsets. For more information about the devices on which proper operation has
been confirmed, please refer to the notes on the right. Please download and install the “FT6381
Communication Software” from the Google Play™ store in order to use the wireless connection
function with an Android™ phone. The software is free, but the user is responsible for any Internet
connection costs incurred in the course of downloading or using the application. Bluetooth® is a
trademark of Bluetooth SIG, Inc. and licensed for use by Hioki E.E. Corporation.
The devices on which proper operation has been confirmed via a Bluetooth® wireless technology in Jul. 2012
In U.S.A. : Sony Tablet S, Droid X, Galaxy Tab, THRiVE, Nitro HD, Iconia A100, Inspire
Bundled Accessories
Carrying case
CLAMP ON EARTH TESTER FT6380, FT6381 can measure Multi-Grounded systems
Refer to the detailed catalog
Field Measuring
Instruments
Measurement Principle
Voltage Injection
Current Measurement
Rx
R1
R2
R3
R4
…………
Clamp on the earth cable. The instrument has two cores for voltage injection and current measurement.
1. The voltage transducer injects a defined voltage into the multi-grounded system.
2.From the defined voltage and measured current, the total circuit loop resistance is
calculated using the following equation.
Rx +
1
1
1
1
1
+
+
+
R1R2R3 R4
…
=
V
Measurement Examples
Actual measured
value
92
Actual measured
value
Actual measured
value
I
In a typical multi-grounded system, the parallel resistance value is small enough to
be ignored and the equation as referred on the left can be simulated as follows.
Rx =
V
I
• In a multi-grounded system, the larger the number of grounding poles, the
more accurate the measured value.
• Where the number of grounding poles are few, if just only one carries a very
small resistance (e.g., 1 Ω), the measured value will be close to the true value.
• On the other hand, poles with large resistances (e.g., 100 Ω) will result in
greater measurement uncertainties.
Earth Testers/Voltage Detectors
3-electrode measurement on the 3151 gives greater precision !
EARTH HiTESTER 3151
■ Basic specifications (Accuracy guaranteed for 1 year)
AC potentiometer method, 3-pole measurement, 2-pole measurement
Operating system Note: When using 2-pole method, applies only when the measurement range of 100
CAT II 30 V
Ω (0 to 115 Ω) and 1000 Ω (0 to 1150 Ω)
10 Ω (0 to 11.5 Ω)
100 Ω (0 to 115 Ω)
1000 Ω (0 to 1150 Ω)
Measurement range
±2.5 % f.s.
±2.5 % f.s.
±2.5 % f.s.
Accuracy
30 V (0 to 30 V), Accuracy: ±3.0 % f.s.
Earth voltage
Switchable testing frequency (575 Hz, or 600 Hz), Auxiliary earthing (P/C pole)
Functions
resistance check
R6P (AA) manganese battery ×6 (Continuous use: 350 times), or LR6 (AA)
Power supply
alkaline battery ×6 (Continuous use: 1100 times) (at 30 sec measurement/ 30 sec
pause cycle)
Dimensions and mass 164 mm (6.46 in)W × 119 mm (4.69 in)H × 88 mm (3.46 in)D, 800 g (28.2 oz)
Auxiliary earthing rod 9214 ×2, Measuring cable 9215 (Black 5 m (16.41 ft),
Yellow 10 m (32.81 ft), Red 20 m (65.62 ft), each one, Cable winder×3), Carrying
Accessories
case 9393 ×1, Hand strap ×1, R6P (AA) manganese battery ×6, Instruction
manual ×1
Note: 2 pieces of Model 9214 are bundled as standard accessories
MEASURING CABLE
9215
AUXILIARY
Black 5 m (16.41 ft), Yellow EARTHING ROD
CARRYING CASE 10 m (32.81 ft), Red 20 m
9214
9393
(65.62 ft), each one, Cable
winder×3
Options
Bundled Accessories
•Wide measurement range for 0 to 1150 Ω, based on EN standard
•Switchable measurement frequency to minimize the influence of harmonic
earth voltage
•Semi-dust-proof construction
EARTH NETS 9050
Set of two, 30 cm (11.81 in)
× 30 cm (11.81 in)
Twin Light Audible Voltage Detector
VOLTAGE DETECTOR 3120
CAT IV 600 V
Dimensions and
mass
149 mm (5.87 in)H × φ 18.5 mm (0.73 in), 38 g (1.3 oz)
Accessories
Instruction manual ×1, R03 (AAA) manganese battery ×2 (for trial purposes only)
Field Measuring
Instruments
•Top “primary supply level” safety class rating for voltage detectors
•CAT IV 600 V design meets CE Mark qualifications
•Continuously indicates battery status with green indicator lamp
•Provides both visual and audible voltage detection indication
•Automatic power switching prevents battery discharge
■ Basic specifications
Measurement
Voltage detection
function
Measurement volt- 70 to 600 VAC, 50/60 Hz (when in contact with an IV 2 mm2 or equivalent insulated wire)
age
The red LED lights up and the buzzer sounds when the wire is live
Pilot light
Green LED
Battery check
R03 (AAA) manganese or LR03 (AAA) alkaline battery ×2, Continuous use: 200 hr
Power supply
(using the LR03 batteries)
93
Phase Detector
Non-Metallic Contact for Optimal Safety
PHASE DETECTOR 3129-10
CAT IV 600 V
CAT III 1000 V
Compatible wires
IV cable: 14 mm2 to 500 mm2, single wire 5 mm to
CV cable: 3.5 mm2 to 500 mm2
•Magnetic base allows the instrument to be secured on a distribution panel
•Simply clip clamps onto wire insulation
•Rotating LED indicator indicates the phase sequence for a 3-phase power
supply at a glance
•Intermittent beeps signal positive phase; continuous tone signals reverse
phase
■ Basic specifications
Phase detection (positive and negative)
Functions
Voltage detection
Static induction
method
70 to 1000 V AC (50/60 Hz) (sine wave,continuous input)
Voltage range
Frequency range 45 Hz to 66 Hz
7 mm (0.28 in) to 40 mm (1.57 in) of insulated wiring
Object to be conIV, HIV cable: 14 to 500 mm^2
nected
CV cable: 3.5 to 500 mm^2
Phase detection : Positive ; 4 LEDs lit in clockwise order and the buzzer
sounds intermittently
Display
Negative ; 4 LEDs lit in counterclockwise order and the buzzer sounds
continuously
Battery check
Power ON lamp: lights up (Power ON), blinks (Battery LOW)
function
Auto shut off if no activity is detected after power is turned ON for 15 minutes
Auto power off
R6P (AA) manganese battery ×2, Continuous use: 70 hr
Power supply
70 mm (2.76 in)W × 75 mm (2.95 in)H × 30 mm (1.18 in)D, 240 g (8.5 oz),
Dimensions and
Cord length : 0.7 m (2.30 ft)
mass
Carrying case ×1, Strap ×1, Spiral tube ×1, Instruction manual ×1, R6P (AA)
Accessories
manganese battery ×2
Non-Metallic Contact for Optimal Safety
PHASE DETECTOR 3129
CAT III 600 V
Compatible wires
IV cable: Up to 100 mm2
Field Measuring
Instruments
•Magnetic base allows the instrument to be secured on a distribution panel
•Simply clip clamps onto wire insulation
•Rotating LED indicator indicates the phase sequence for a 3-phase power
supply at a glance
•Intermittent beeps signal positive phase; continuous tone signals reverse
phase
■ Basic specifications
Phase detection (positive and negative)
Functions
Voltage detection
Static induction
method
70 to 600 V AC (50/60 Hz) (sine wave,continuous input)
Voltage range
Frequency range 45 Hz to 66 Hz
2.4 mm (0.09 in) to 17 mm (0.67 in) of insulated wiring
Object to be conIV, HIV cable: 2 to 100 mm2
nected
CV cable: 2 to 60 mm2
Phase detection :Positive ; 4 LEDs lit in clockwise order and the buzzer
sounds intermittently
Display
Negative ; 4 LEDs lit in counterclockwise order and the buzzer sounds
continuously
Battery check
Power ON lamp: lights up (Power ON), blinks (Battery LOW)
function
Auto shut off if no activity is detected after power is turned ON for 15 minutes
Auto power off
R6P (AA) manganese battery ×2, Continuous use: 70 hr
Power supply
70 mm (2.76 in)W × 75 mm (2.95 in)H × 30 mm (1.18 in)D, 200 g (7.1 oz),
Dimensions and
Cord length : 0.7 m (2.30 ft)
mass
Carrying case ×1, Strap ×1, Spiral tube ×1, Instruction manual ×1, R6P (AA)
Accessories
manganese battery ×2
Highly dependable and compact instrument
PHASE DETECTOR 3126-01
Not CE Marked
■ Basic specifications
110 to 480 V AC (40 Hz to 70 Hz)
Voltage range
30 minutes /220 V AC, 4 minutes /480 V AC
Time limits
Connection cable
1.2 m (R: red, S: white, T: blue), with clip and fuse holder (700 V/ 0.5 A fuse)
length
Dimensions and
70 mm (2.76 in)W × 96 mm (3.78 in)H × 54 mm (2.13 in)D, 280 g (9.9 oz)
mass
Carrying case ×1, Instruction manual ×1, Spare fuse ×1
Accessories
The electric power of three-phase line
Indicator dial
•Rotating disc indicates the phase sequence for a 3-phase power supply
at a glance
•Compact, lightweight design is conveniently portable
•Includes convenient soft case for carrying
Rotating dial
94
CT/Shunts
Expand input range use with Meter Relays (50/60 Hz, 1.0 % class)
CURRENT TRANSFORMER CT-5MRN series
■ Dimensions and connecting diagrams
Not CE Marked
N=(Primary current of the CT)÷(Full scale value of the Meter)
* Wind so that N loops of the conductor (as calculated above) pass through the center hole. For
example, for 120 A:30 A, 4 loops (120 A / 30 A
= 4) should pass through the center hole.
■ Dimensions table
■ Basic specifications
Model
CT-5MRN100
CT-5MRN120
CT-5MRN150
Primary
100 A
120 A
150 A
Symbol
Secondary Rated load
5A
5 VA
5A
5 VA
5A
5 VA
Class
1.0 %
1.0 %
1.0 %
Max. rated voltage
1150 V
1150 V
1150 V
Length
Symbol
Length
φA
B
C
D
23 mm (0.91 in) 70 mm (2.76 in) 85 mm (3.35 in) 68 mm (2.68 in)
φE
F
G
H
60 mm (2.36 in) 45 mm (1.77 in) 75 mm (2.95 in) 83 mm (3.27 in)
Expand current range use with the 50 mV full scale meter (50/60 Hz, 0.5 % class)
EXTERNAL SHUNT HS-1 series
■ Dimensions and connecting diagrams
Not CE Marked
•Expand current range for the Meter Relay, or a switchboard meter
•Combination use with the 50 mV meter
devices used should not exceed 0.1 Ω
■ Basic specifications
Model
HS-1-30
HS-1-50
HS-1-75
HS-1-100
HS-1-150
HS-1-200
Rated current
30 A
50 A
75 A
100 A
150 A
200 A
HS-1-300
300 A
* Please note that connections' cores are not included. The total resistance of all shunt
* If product includes an instrument number or is packaged with an instrument, use in com-
Class
bination with that instrument
* Select a model such that input does not exceed 80 % of the rating. (0.5 accuracy definition
requirements: 80 % or less of rated input, ambient temperature of 60 °C or less)
±0.5 % at 80 % of rated current
60 °C or less around temperature
■ Dimensions table
±0.5 % at 0 A to 200 A
±1.0 % at 200 A to 240 A
60 °C or less around temperature
The total resistance of the connection cord must be 0.1 Ω or less
E
F
d
D
20 mm (0.79 in)
20 mm (0.79 in)
20 mm (0.79 in)
20 mm (0.79 in)
20 mm (0.79 in)
25 mm (0.98 in)
25 mm (0.98 in)
6 mm (0.24 in)
8 mm (0.31 in)
8 mm (0.31 in)
15 mm (0.59 in)
15 mm (0.59 in)
15 mm (0.59 in)
15 mm (0.59 in)
M4 mm
M4 mm
M4 mm
M5 mm
M5 mm
M5 mm
M5 mm
M5 mm
M8 mm
M8 mm
M8 mm
M8 mm
M10 mm
M10 mm
Clamp-type CT that enables measurement in excess of 1,000 A (clamp ammeter option/AC use only)
CLAMP ON ADAPTER 9290-10
CAT III 600 V
Primary side
1000 A
Secondary side
100 A
• Outputs large currents of 1,000 A AC continuously (1,500 A for 5 minutes) at a CT ratio of 10:1
• Expands the measurement range of normal clamp ammeters
• Provides excellent phase characteristics and can also be used to expand power meter measurement ranges
Other Testing
Equipments
Note: These products are built-to-order so please confirm specifications and delivery time with
your local HIOKI distributor.
Symbol
HS-1-30
HS-1-50
HS-1-75
HS-1-100
HS-1-150
HS-1-200
HS-1-300
■ Basic specifications (Accuracy guaranteed for 1 year)
Rated primary current AC 1000 A continued (Maximum 1500 A for 5 minutes or shorter)
Rated secondary current AC 100 A (10 : 1 CT ratio)
±1.5% rdg.
Amplitude Accuracy
±1.0° or less
Phase Accuracy
Amplitude: 20 Hz to 5 kHz: ±2.0 % rdg. (deviation from accuracy)
Frequency
Phase: 20 Hz to 5 kHz: ±1.0° or less (deviation from accuracy)
characteristics
Max. rated voltage to
600 V AC rms (insulated wire)
earth
φ55 mm (2.17 in) or 80 mm (3.15 in) × 20 mm (0.79 in) bus-bar
Core jaw dia.
99.5 mm (3.92 in)W × 188 mm (7.40 in)H × 42 mm (1.65 in)D, 580 g
Dimensions and mass
(20.5 oz), cord length 3 m (9.84 ft)
Instruction manual ×1, Mark band ×6
Accessories
Note: Cannot use with the Model 9279
95
Analog Meter Relays
Advancing power saving and automation
METER RELAY 2103H/L/HL, 2104H/L/HL
Not CE Marked, Photo
shows Model 2103HL
Not CE Marked, Photo
shows Model 2104HL
•Ultra sensitive 1 µA, 10 mV DC movement
•Includes a display lamp to illuminate movement at a glance
•Relay action delays circuit closure upon power on
•Both power circuitry and relay built-in
*H-type: Lamp lights up and output relay contact operates at deflection of the
needle to the right of the setting needle
*L-type: Lamp lights up and output relay contact operates at deflection of the
needle to the left of the setting needle
*HL-type: Provides functionality of both H- and L-type models
■ Basic specifications (Accuracy guaranteed for 1 year)
φ 0.3 mm (0.01 in) pin
Indicator shape
[2103H/L/HL]: 2.5 %, [2104H/L/HL]: 1.5 %
Accuracy class
Within 1.5 % of the full scale value (Independent of meter section)
Setting accuracy
Within 0.5 % of the scale length
Dead-zone width
Indicator operating range Within the scale (passing indicator needle system)
Spear shape
Setting indicator
H indicator (upper-limit side): Red, L indicator (lower-limit side): Green
(shape and color)
Setting indicator setting range Within the all range of scale for both H and L
Within 3 % of the scale length
Minimum H/L space
Delay time from power on Approx. 2 s (time constant)
Relay contact structure One transfer for both H and L
Relay output response Approx. 0.5 s
Max. current of relay
5 A (Under condition of 250 V AC, 30 V DC, resistance load)
contact
100 V/200 VAC (to be specifi ed at the time of ordering) 50/60 Hz,
Power supply
3 VA max.
■ Dimensions
Use bracket to mount the 2103
• 2.5 % class, Panel size: 84 mm (3.31 in)
2103H (H type, upper-limit setting)
2103L (L type, lower-limit setting)
2103HL (HL type, upper/lower-limit setting)
Model 2103 panel
cutout
Panel thickness
Model 2104 panel
cutout
• 1.5 % class, Panel size: 104 mm (4.09 in)
2104H (H type, upper-limit setting)
2104L (L type, lower-limit setting)
2104HL (HL type, upper/lower-limit setting)
Note: These products are built-to-order so please confirm specifications and delivery time with
your local HIOKI distributor.
Panel thickness
Mount the 2104 with 4 nuts
■ Contact operation
When considering the purchase of Meter Relays:
■ Standard scale graduations
• A Product Guide describing the specifications as well as a Meter Relay
Specifications Check List are available.
• Please contact your local Hioki distributor or sales subsidiary for more
information.
The Product Guide is also available for download at www.hioki.com
e.g. for full- Graduations
scale value
2103, 2104 (Rear view)
Terminal arrangement
(When power is OFF)
Meter Relays
1, 10, 100
50
1.5, 15, 150
30
2, 20, 200
40
2.5, 25, 250
50
3, 30, 300
30
4, 8, 40
40
5, 50, 500
50
6, 60, 600
30
7.5, 75, 750
37.5
Guraduation illustration
■ Standard Full-scale Values
DC Ammeter
Standard
full-scale
value
Special Specifications
96
•±1.5% class: For Model 2103
•Extended scale: Double or triple extended scale
•Segmented scale: Magnified scale for up to 40 % of the maximum scale value, exclusive
4-20 mA scale model, or 1-5 V scale model
•Double deflection meter: For example, zero-centered scale
•Relay response time: Time constant 0.05 second fixed (DC) and variable types also
available
•Delay time: Version with variable delay time after power on. 0.1 to 10 seconds: (for
instruments input DC), 2 to 12 seconds: (for instruments input AC)
•Output signal: Version with 1 V DC /f.s. output terminal
*Not isolated from input circuit ground.
•True RMS rectified with AC current meter, or AC voltage meter
•Specify a scale, or a unit
Meter
sensitivity
spec.
1 µA
10 µA
20 µA
50 µA
100 µA
200 µA
500 µA
1 mA
2 mA
5 mA
10 mA
20 mA
50 mA
100 mA
200 mA
500 mA
1A
2A
5A
10 A
20 A
50 mV
Full-scale:
4 - 20 mA
50 mV
DC Voltmeter
Rectifying AC ammeter Rectifying AC voltmeter
Standard
full-scale
value
Meter
sensitivity
spec.
Standard
full-scale
value
10 mV
15 mV
30 mV
50 mV*1
100 mV
150 mV
300 mV
500 mV
1V
1.5 V
3V
5V
10 V
15 V
30 V
50 V
100 V
150 V
300 V
100 kΩ/V
100 kΩ/V
100 kΩ/V
100 kΩ/V
100 kΩ/V
100 kΩ/V
100 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
200 µA
500 µA
1 mA
2 mA
5 mA
10 mA
20 mA
50 mA
100 mA
200 mA
500 mA
1A
2A
3A
5 A*2
Full-scale:
1-5V
10 kΩ/V
Meter
sensitivity
spec.
Standard
full-scale
value
Meter
sensitivity
spec.
50 mV
50 mV
100 mV
150 mV
300 mV
500 mV
1V
1.5 V
3V
5V
10 V
15 V
30 V
50 V
100 V
150 V
300 V
10 kΩ/V
10 kΩ/V
10 kΩ/V
10 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
1 kΩ/V
*1. When the full-scale value is larger than 20 A
DC, an external shunt device is used with the 50
mV instrument denoted by.
*2. When the full-scale value is larger than 5 A AC,
an external CT is used with the 5 A instrument
denoted by.
Model No. Index
Model No.
Name
MEASURING LEAD (RED)
MEASURING LEAD (BLACK)
MEASURING LEAD (RED)
MEASURING LEAD (BLACK)
MEASURING LEAD (BLACK)
MEASURING LEAD (RED)
RECORDING PAPER
RECORDING PAPER
METER RELAY
METER RELAY
METER RELAY
METER RELAY
METER RELAY
METER RELAY
MULTI TESTER
HiTESTER
VOLTAGE DETECTOR
PHASE DETECTOR
PHASE DETECTOR
PHASE DETECTOR
EARTH HiTESTER
PageNote
-- For DSM-LR20
-- For DSM-LB20
46 For DSM-8104, SM-8200 series
46 For DSM-8104, SM-8200 series
46 For DSM-8104, SM-8200, SM-23 series
46 For DSM-8104, SM-8200, SM-23 series
-- For the 1120, 1121, 3192 (9430), 60mm width
36 For the 9442, 112mm width
96
96
96
96
96
96
82
82
93 Model name 3120
94
94
94
93
AUTOMATIC INSULATION / WITHSTANDING HiTESTER53
DIGITAL MΩ HiTESTER
55
AC GROUNDING HiTESTER
55
INSULATION / WITHSTANDING HiTESTER 54 For 220V power supplies only
CLAMP ON POWER HiTESTER
59 English model
CLAMP ON POWER HiTESTER
59 English model
AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER53
POWER HiTESTER
63
POWER QUALITY ANALYZER
59
DIGITAL HiTESTER
49
DIGITAL HiTESTER
49
DIGITAL HiTESTER
49
DIGITAL HiTESTER
49
DIGITAL HiTESTER
49
DIGITAL HiTESTER
49
CARD HiTESTER
81
SOLAR HiTESTER
81
PENCIL HiTESTER
81
DIGITAL HiTESTER
80
SAFETY HiTESTER
80
POWER SUPPLY
64 For the 3273 to 3276
POWER SUPPLY
64 For the 3273 to 3276
CLAMP ON PROBE
64
CLAMP ON PROBE
64
CLAMP ON PROBE
64
CLAMP ON PROBE
64
CLAMP ON HiTESTER
91
CLAMP ON HiTESTER
91
DIGITAL CLAMP ON HiTESTER
91
DIGITAL CLAMP ON HiTESTER
91
CLAMP ON LEAK HiTESTER
87
CLAMP ON AC/DC HiTESTER
90
CLAMP ON AC/DC HiTESTER
90
CLAMP ON AC/DC HiTESTER
90
CLAMP ON POWER HiTESTER
89
CLAMP ON AC/DC HiTESTER
89
CLAMP ON AC/DC HiTESTER
89
CLAMP ON AC/DC HiTESTER
89
CLAMP ON AC/DC HiTESTER
88
CLAMP ON AC/DC HiTESTER
88
CLAMP ON HiTESTER
88
CLAMP ON LEAK HiTESTER
87
POWER HiTESTER
62
POWER HiTESTER
62
POWER HiTESTER
61
POWER HiTESTER
61
AC/DC POWER HiTESTER
61
AC/DC POWER HiTESTER
61
POWER ANALYZER
56
POWER ANALYZER
56
LUX HiTESTER
75
TEMPERATURE HiTESTER
74
TEMPERATURE HiTESTER
74 For North America, C/ F selectable
TEMPERATURE HiTESTER
74
HIGH VOLTAGE INSULATION HiTESTER
86
HIGH VOLTAGE INSULATION HiTESTER
-- Chinese model
ANALOG MΩ HiTESTER
85
C HiTESTER
37
C HiTESTER
37
C HiTESTER
37
C METER
37
LCR HiTESTER
36
LCR HiTESTER
35
LCR HiTESTER
35
RESISTANCE HiTESTER
42
BATTERY HiTESTER
44
BATTERY HiTESTER
44
BATTERY HiTESTER
43
BATTERY HiTESTER
43
OPTICAL POWER METER
70
LAN CABLE HiTESTER
71 English model
CARRYING CASE
21 For the 9322/ 3661/ 3256/ 3257 or other
HIGH VOLTAGE SCANNER
52
MICRO HiCORDER
19
MICRO HiCORDER
19
MEMORY HiLOGGER
24
Model No.
Name
8826
MEMORY HiCORDER
8860-50
MEMORY HiCORDER
8861-50
MEMORY HiCORDER
8870-20
MEMORY HiCORDER
8870-21
MEMORY HiCORDER
8910
CAN ADAPTER
8936
ANALOG UNIT
8937
VOLTAGE/TEMP UNIT
8938
FFT ANALOG UNIT
8939
STRAIN UNIT
8940
F/V UNIT
8946
4ch ANALOG UNIT
8947
CHARGE UNIT
8948
VOLTAGE/TEMP UNIT
8949
UNIVERSAL UNIT
8956
ANALOG UNIT
8957
HIGH RESOLUTION UNIT
8958
16ch SCANNER UNIT
8959
DC/RMS UNIT
8960
STRAIN UNIT
8961
HIGH VOLTAGE UNIT
8966
ANALOG UNIT
8967
TEMP UNIT
8968
HIGH RESOLUTION UNIT
8969
STRAIN UNIT
8970
FREQ UNIT
8971
CURRENT UNIT
8972
DC/RMS UNIT
8973
LOGIC UNIT
8995
A4 PRINTER UNIT
8995-01
A6 PRINTER UNIT
8996
DIGITAL/PULSE UNIT
8997
ALARM UNIT
9010-50
CLAMP ON PROBE
9014
HIGH VOLTAGE PROBE
9017
HIGH VOLTAGE PROBE
9018-50
CLAMP ON PROBE
9032
METAL CONTACT TIP
9033
RUBBER CONTACT TIP
9050
EARTH NETS
9060
TEST LEAD
9073
RECORDING PAPER
9074
RECORDING PAPER
9094
OUTPUT CORD
9099
CLIP TYPE LEADS
9132-50
CLAMP ON PROBE
9140
4-TERMINAL PROBE
9140-10
4-TERMINAL PROBE
9143
PINCHER PROBE
9143-10
PINCHER PROBE
9151-02
GP-IB CONNECTOR CABLE
9165
CONNECTION CORD
9166
CONNECTION CORD
9168
INPUT CORD
9180
SHEATH TYPE TEMPERATURE PROBE
9181
SURFACE TEMPERATURE PROBE
9182
SHEATH TYPE TEMPERATURE PROBE
9183
SHEATH TYPE TEMPERATURE PROBE
9184
TEMPERATURE PROBE
9195
ENCLOSURE PROBE
9197
CONNECTION CORD
9199
CONVERSION ADAPTER
9203
DIGITAL PRINTER
9211
9212
PERIPHERAL RING
9213
CONTACT ADAPTER
9214
AUXILIARY EARTHING ROD
9215
MEASURING CABLE
9219
CONNECTION CABLE
9221
RECORDING PAPER
9222
RECORDING PAPER
9223
RECORDING PAPER
9229
RECORDING PAPER
9229-01
RECORDING PAPER
9231
RECORDING PAPER
PageNote
18
17
17
17
--
21
17
17
17
17
17
17
17
24
24
17
17
17
17
17
17
18
18
18
18
18
18
18
18
17
17
24
24
67
--
82
67
75
75
93
82
--
--
23
--
67
38
38
38
38
61
23
35
50
74
74
74
74
50
51
22
23
36
75
75
--
93
93
68
--
--
--
18
18
17
9232
RECORDING PAPER
63
9233
9234
RECORDING PAPER
RECORDING PAPER
36
16
9235
9236-01
RECORDING PAPER
RECORDING PAPER
19
19
9237
9242
9243
9246
9248
9249
9261
9261-10
9262
9263
9267
9268
9268-01
RECORDING PAPER
CONNECTION CORD
GRABBER CLIP
CARRYING CASE
POWER CORD
CARRYING CASE
TEST FIXTURE
TEST FIXTURE
TEST FIXTURE
SMD TEST FIXTURE
--
--
22
70
21
71
38
38
38
38
SAFETY TEST DATA MANAGEMENT SOFTWARE 52
DC BIAS VOLTAGE UNIT
35
DC BIAS VOLTAGE UNIT
35
English model
Chinese model
For the 8860-50, 8861-50, or other models
For the 8860-50, 8861-50, or other models
For the 8860-50, 8861-50, or other models
For the 8860-50, 8861-50, or other models
For the 8860-50, 8861-50, or other models
For the 8860-50, 8861-50, or other models
For the 8860-50, 8861-50, or other models
For the 8423
For the 8423
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the MR8847 series, MR8740/41 series
For the MR8847 series, MR8740/41 series
For the MR8847 series, MR8740/41 series
For the MR8847 series, MR8740/41 series
For the MR8847 series, MR8740/41 series
For the MR8847 series, MR8740
For the MR8847 series, MR8740/41 series
For the MR8847 series, MR8740/41 series
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8423
For the 8423
For the 3256/57, 3800 series
For the 3030-10
For the FT3405/06, 3403/04
For the FT3405/06, 3403/04
For the 3151
For the 3008
For the 8201/02/04
For the 8203, 1ch
For the 8800s, 3283/84/85 or other models
For the 3224/3220
For the 3511/22/31/32 or other models
For the IM3590/3570/3533/3523 or other models
For the 3511/22/31/32 or other models
For the IM3590/3570/3533/3523 or other models
For the 3334 or other models
For the 8800 series, 9268 or other models
For the 9268, or other models
For the SS7012, 7011/10
For the 3441/42 or other models
For the 3441/42 or other models
For the 3441/42 or other models
For the 3441/42 or other models
For the SS7012, 7011
For the ST5540 series, 3156/3155
For the 8800 series
For the 8800 series
For the FT3405/06, 3403/04
For the FT3405/06, 3403/04
For the 3403/04
For the 3151
For the 3151
For the 9695-02/-03
For the 8835-01, 8815/30/35, 8852, 110mm width
For the 9200, 9514, 38mm width
For the 3165, 3191, 80mm width
For the 8826, 8825, 264mm width
For the 8826, 8825, 264mm width (Perforated)
For the 8860-50/8861-50,
8855/46/45/42/41/40, 216mm width
For the 3193-10, 8804 or other models,
74mm width
For the 9203, 3155, 58mm width
For the MR8880-20, 8807/08, 8420 series,
112mm width
For the 8205-10, 8206-10, 60mm width
For the 8205-10, 8206-10, 60mm widht
(Climate-resistant)
For the 9670 (PW3198/96, 3561/41), 80mm width
For the 8961 (8860/61s)
For the 8800 s, L4930/9197, 9322
For the 3664
For the 9322 to 9687 connect
For the 3665-20
For the 3532-50 or other models
For the IM3590/3570/3533/3523 or other models
For the 3532-50 or other models
For the 3532-50 or other models
For the 3153, 3156/57/58/59, 3332
For the 3532-50 or other models
For the 3532-50 or other models, for HDMI
Other
0GA00003
0GA00004
0GA00007
0GA00008
0GE00001
0GE00002
1195
1196
2103H
2103HL
2103L
2104H
2104HL
2104L
3008
3030-10
3120-20
3126-01
3129
3129-10
3151
3153
3154
3157-01
3159-02
3169-20
3169-21
3174
3193-10
3197
3237
3237-01
3238
3238-01
3239
3239-01
3244-60
3245-60
3246-60
3255-50
3258
3269
3272
3273-50
3274
3275
3276
3280-10
3280-20
3281
3282
3283
3284
3285
3285-20
3286-20
3287
3288
3288-20
3290
3290-10
3291-50
3293-50
P3331
3332
3333
3333-01
3334
3334-01
3390
3390-10
3423
3441
3441-02
3442
3455
3455-20
3490
3504-40
3504-50
3504-60
3506-10
3511-50
3532-50
3535
3541
3554
3555
3561
3561-01
3664
3665-20
3853
3930
8205-10
8206-10
8423
Note: P marked products are discontinued models.
97
Model No. Index
Model No.
Other
9268-10
9269
9269-10
9272-10
9277
9278
9279
9286
9287-10
9288
9290-10
9292
9293
9296
9297
9299
9300
9318
9319
9320
9320-01
9322
9323
9324
P9325
9327
9328
9333
9335
9344
9345
9355
9371
9375
9376
9378
9380
9382
9384
9386-01
P9388
9390
9393
P9397-01
9398
9399
9400
9418-15
9425
9436
9440
9441
9442
9443-02
9444
9445-02
9445-03
9446
9447
9451
9452
9453
9454
9455
9458
9459
9460
9461
9465
9465-10
9465-90
9466
9467
9472
9472-50
9473
9473-50
9474
9475
9476
9476-50
9478
P9479
9500
9500-10
9518-01
9518-02
9555-10
9588
9593-01
9593-02
9599
9600
9601
9602
9603
9604
98
Name
DC BIAS VOLTAGE UNIT
DC BIAS CURRENT UNIT
DC BIAS CURRENT UNIT
CLAMP ON SENSOR
UNIVERSAL CLAMP ON CT
UNIVERSAL CLAMP ON CT
UNIVERSAL CLAMP ON CT
TEST PROBE
CLIP TYPE LEAD
BREAKER PIN
CLAMP ON ADAPTER
TEST PROBE
PIN TYPE EARTH PROBE
CURRENT PROBE
CURRENT APPLY PROBE
SWITCHED PROBE
CONNECTION CABLE
CONVERSION CABLE
CONVERSION CABLE
LOGIC PROBE
LOGIC PROBE
DIFFERENTIAL PROBE
CONVERSION CABLE
POWER CORD
POWER CORD
LOGIC PROBE
POWER CORD
LAN COMMUNICATOR
WAVE PROCESSOR
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
CARRYING CASE
AC ADAPTER
CONNECTION CABLE
CONNECTION CABLE
CONNECTION CABLE
CONNECTION CABLE
PRINTER
AC ADAPTER
CONNECTION CABLE
AC ADAPTER
AC ADAPTER
CONNECTION CABLE
BATTERY PACK
TEMPERATURE PROBE
CLIP TYPE LEAD
FOUR TERMINAL LEAD
ZERO ADJUSTMENT BOARD
PIN TYPE LEAD
AC ADAPTER
BATTERY PACK
PageNote
32 For the IM3590/3570/3533/3523 or other models
35 For the 3532-50 or other models
32 For the IM3590/3570/3533/3523 or other models
67
65
65
65
-- For the 3119-11 MΩ HiTESTER
39 For the RM3548, 3561/60, 3541/40 or other models
-- For the 9292/9294 (3451 to 3454)
95
-- For the 3451, 3452
-- For the 3451, 3452
55 For the 3157-01
55 For the 3157-01
55 For the 3154
42 For the 3541
67 For the 9272-10, 9270/71/72, 9277/78/79
64 For the 3273-50
22 For the 8800 series
22 For the 8800 series
21 For the 8800 series
22 For the 8800 series
21 For the 9322
-- For the 9322
22 For the MR8847 series, 8860 series, 8855
21 For the 9322
20 For the 8826, 8835-01, 8841/42
20 For the 8800 series
19 For the 8205-10, 8206-10
90 For the 3285, 3285-20
67 For the 9272-10, 9270s, or other model
80 For the 3255-50
65 For the 9277 to 9279, Cannot use with the 3286-20
75 For the 3423
-- For the 3256-50, 3257-50
50 For the SS7012, 7011
44 For the 3555, 3550
-- For the 3451, 3452
74 For the 3441/42, 3446/47
-- For the 8835-01
82 For the 3030-10
93 For the 3151
-- For the 8855, 8841, 8720
89 For the 3287/88, 3280-10/-20
90 For the 3284/83/82/81
88 For the 3290
21 For the 9322, 3197 or other models
36 For the 9203
75 For the 3423
59 For the 3169-20/-21, for external control
59 For the 3169-21, for D/A output
36For the ST5540/41, 3511-50 or other models
36 For the Printer 9442, EU type
36 For the Printer 9442
23 For the 3283, 3540 or other models, for USA
23 For the 3283, 3540 or other models, for EU
36 For the Printer 9442
-- For the 8807/08, 8420 series
42 For the 3541, 3540
42 For the 3541, 3540 or other models
39 For the RM3548, 3561/60, 3541/40 or other models
43 For the L2100, 9465-10, 9465, 9461
42 For the 3541, 3540 or other models
-- For the 3196
57 For the PW3360s, 3351, 3197, 3455
CLIP TYPE LEAD WITH TEMPERATURE SENSOR 44 For the 3554, 3540 or other models
PIN TYPE LEAD
44 For the 3555, 3541, 3540
PIN TYPE LEAD
-- For the 3551
PIN TYPE LEAD
39 For the RM3548, 3554 or other models
TIP PIN
39 For the 9465-10
REMOTE CONTROL SWITCH
44 For the 9465 (for the 3554/51, 3560)
LARGE CLIP TYPE LEAD
39 For the RM3548, 3561, 3541/40 or other models
SHEATH TYPE TEMPERATURE PROBE
74 For the 3441, 3442 or other models
SHEATH TYPE TEMPERATURE PROBE
74 For the 3446-01 only
SHEATH TYPE TEMPERATURE PROBE
74 For the 3441, 3442 or other models
SHEATH TYPE TEMPERATURE PROBE
74 For the 3446-01 only
SHEATH TYPE TEMPERATURE PROBE
74 For the 3441, 3442 or other models
SHEATH TYPE TEMPERATURE PROBE
74 For the 3441, 3442 or other models
SURFACE TYPE TEMPERATURE PROBE 74 For the 3441, 3442 or other models
SURFACE TYPE TEMPERATURE PROBE 74 For the 3446-01 only
SHEATH TYPE TEMPERATURE PROBE
74 For the IM3533, IM3533-01, 3447, Pt100
SHEATH TYPE TEMPERATURE PROBE
74 For the 3447-01, with switch
4-TERMINAL PROBE
41 For the RM3543, 3532-80
4-TERMINAL PROBE
32 For the IM3590/3570/3533/3523 or other models
GP-IB INTERFACE
35 For the 3532-50 or other models
GP-IB INTERFACE
55 For the 3157-01
SENSOR UNIT
65
GP-IB INTERFACE
-- For the 3560, 3330, 3227, 3187/67
RS-232C INTERFACE
35 For the 3532-50 or other models
RS-232C INTERFACE
55 For the 3157-01
MEMORY BOARD
18 For the 8826 only
AC/DC DIRECT INPUT UNIT
63 For the 3193-10, 3194
AC DIRECT INPUT UNIT
63 For the 3193-10, 3194
AC/DC CLAMP INPUT UNIT
63 For the 3193-10, 3194
EXTERNAL SIGNAL INPUT UNIT
63 For the 3193, 3193-10 only
PRINTER UNIT
63 For the 3193-10, 3194
Model No.
9605
9612
9613
9614
9615
9615-01
9624-50
9625
9629
9630
9631-01
9631-02
9631-03
9631-04
9631-05
9631-11
9631-14
9631-21
9631-24
9632
9637
9638
9639
9641
9642
9650
9651
9657
9657-10
9658
9660
9661
9664
9665
9666
9668
9669
9674
9675
9677
9678
9680-50
9680-51
9680-52
9683
9684
9687
9690-01
9690-02
9690-03
9690-04
9694
9695-02
9695-03
9696
9699
9700-10
9701
9704
9705
9706
9709
9709-10
9713-01
9714-01
9714-02
9715-50
9715-51
9715-52
9715-53
9718-50
9719-50
9720-01
9721
9723
9724
9725
9727
9728
9729
9730
9731
9732
9733
9734
9738
9739
9742
9742-10
9743
9743-10
9750-01
9750-02
9750-03
9750-11
9750-12
9750-13
Name
Note: P marked products are discontinued models.
PageNote
HARMONIC/FLICKER MEASUREMENTS UNIT
RS-232C CABLE
REMOTE CONTROL BOX (SINGLE)
REMOTE CONTROL BOX (DUAL)
H.V. TEST LEAD
H.V. TEST LEAD
PQA-HiVIEW PRO
POWER MEASUREMENT SUPPORT SOFTWARE
CONNECTION CABLE
HUMIDITY SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR
TEMPERATURE SENSOR
CONNECTION CABLE
RS-232C CABLE
RS-232C CABLE
CONNECTION CABLE
CONNECTION CABLE
LAN CABLE
CLAMP ON SENSOR
CLAMP ON SENSOR
CLAMP ON LEAK SENSOR
CLAMP ON LEAK SENSOR
CLAMP ON LEAK SENSOR
CLAMP ON SENSOR
CLAMP ON SENSOR
HD UNIT
10:1 PROBE
100:1 PROBE
CLAMP ON SENSOR
CLAMP ON SENSOR
RS-232C PACKAGE
CLAMP ON LEAK SENSOR
SMD TEST FIXTURE
CONNECTION CABLE
HUMIDITY SENSOR
HUMIDITY SENSOR
HUMIDITY SENSOR
CONNECTION CABLE
DC POWER UNIT
PROBE POWER UNIT
TERMINATOR(ID1-5)
TERMINATOR(ID6-10)
TERMINATOR(ID11-15)
TERMINATOR(ID16-20)
CLAMP ON SENSOR
CLAMP ON SENSOR
CLAMP ON SENSOR
CARRYING CASE
SMD TEST FIXTURE
HEAD AMP UNIT
HUMIDITY SENSOR
CONVERSION ADAPTER
CONVERSION CABLE
EXTENSION CABLE
AC/DC CURRENT SENSOR
AC/DC CURRENT SENSOR
CAN CABLE
LOGIC CABLE
LOGIC CABLE
MEMORY BOARD
MEMORY BOARD
MEMORY BOARD
MEMORY BOARD
HD UNIT
MEMORY BACKUP UNIT
CARRYING CASE
RS-232C CABLE
CARRYING CASE
CARRYING CASE
MEMORY HiVIEWER
PC CARD 256M
PC CARD 512M
PC CARD 1G
CARRYING CASE
FC CONNECTOR ADAPTER
SC CONNECTOR ADAPTER
FC CONNECTOR ADAPTER
SC CONNECTOR ADAPTER
OPTICAL CONNECTOR CLEANER
SPARE CLEANER
OPTICAL SENSOR
OPTICAL SENSOR
OPTICAL SENSOR
OPTICAL SENSOR
TEST LEAD
TEST LEAD
TEST LEAD
TEST LEAD
TEST LEAD
TEST LEAD
63
59
53
53
53
52
58
59
--
--
--
--
--
--
--
--
--
-
--
--
43
43
--
24
22
68
68
--
68
--
68
68
18
22
22
68
68
--
68
38
35
--
--
--
24
--
21
71
71
71
71
68
68
68
--
38
35
--
67
67
67
66
56
21
21
21
17
17
17
17
17
--
59
59
22
22
20
22
22
22
--
--
--
--
--
--
--
70
70
70
70
86
86
86
86
86
86
For the 3193, 3193-10 only
For the 3169-20/-21, 8807/8808 series
For the 3174, 3153/57/58/59 series
For the 3174, 3153/57/58/59 series
For the 3174/73/59/58/53
For the 3930
For the PW3198, 3197/96
For the 3169-20/-21, 3166
For the 3639
For the 3631
For the 3630 series
For the 3630 series
For the 3630 series
For the 3630 series
For the 3630 series
For the 3630 series
For the 3630 series
For the 3630 series
For the 3630 series
For the 3630 series
For the BT3563, or other models
For the BT3563, or other models
For the 3637/45
For the LR8431-20, 8430-20 or other models
For the 8800 series, or other models
For the 3638 only
For the 3638 only
For the MR8847 series
For the 8800 series
For the 8800 series
For the 8205-10, 8206-10 only
For the 3446-01, 3447-01
For the IM3570 or other models
For the 3535 only
For the 3641
For the 3641
For the 3641
For the 8423, 3390
For the 8860-50, 8861-50
For the 9322, 8860-50, 8861-50
For the 3665-20
For the 3665-20
For the 3665-20
For the 3665-20
For the 3453-01
For the IM3533, or other models
For the 3535 only
For the 8420-51, 8421-51 only
For the 9132-50, 9018-50, 9010-50 or other models
For the 9270-10, 9709
For the 9270-10, 9709
For the 3390-10 only
For the MR8904, 8910
For the 8910
For the 8910
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 8860-50, 8861-50
For the 3169-20/-21
For the 3169-20/-21 connect to the 9442
For the 8860-50, 8860
For the 8861-50, 8861
For the 8860-50, 8861-50 only
For the 3661-20, 3662-20, 3663-20
For the 3661-20 only
For the 3661-20 only
For the 3662-20, 3663-20 only
For the 3662-20, 3663-20 only
For the 3661-20, 3662-20, 3663-20
For the 3661-20, 3662-20, 3663-20
For the 3664 only
For the 3664 only
For the 3664 only
For the 3664 only
For the 3455
For the 3455
For the 3455
For the 3455
For the 3455
For the 3455
Model No. Index
Model No.
Name
9751-01
9751-02
9751-03
9753
9754
9757
9758
9759
9769
9770
ALLIGATOR CLIP
ALLIGATOR CLIP
ALLIGATOR CLIP
AC ADAPTER
CLAMP ON NOISE SENSOR
CARRYING CASE
EXTENSION CABLE
OUTPUT CABLE
CONVERSION CABLE
PIN TYPE LEAD
86
86
86
86
--
87
72
72
18
43
9771
PIN TYPE LEAD
43
PIN TYPE LEAD
TIP PIN
BATTERY PACK
CARRYING CASE
39
39
17
22
9772
9772-90
9780
9782
22
18
22
22
56
56
56
56
63
57
57
17
17
22
--
43
43
43
43
79
79
78
26
58
58
22
22
57
39
25
73
73
95
95
95
29
65
66
56
66
56
66
68
65
65
65
65
65
65
46
46
46
79
79
79
79
79
78
78
78
78
79
--
--
--
--
--
75
75
73
72
72
73
73
92
92
95
95
95
For the 3455
For the 3455
For the 3455
For the 3455
For the 3145-20
For the 3293-50, 3291-50
For the FT3470-52/-51
For the FT3470-52/-51
For the 8969 (for the MR8847 series)
For the BT3563, BT3562, 3561/55/41 or
other models
For the BT3563, BT3562, 3561/55/41 or
other models
For the RM3548, 3554 or other models
For the 9772
For the 8870-20, LR8431-20, 8430-20 series
For the 8870-20, LR8431-20, 8430-20 series,
SS7012
For the MR8847 series
For the MR8847 series
For the L9790
For the L9790
For the 3390
For the 3390
For the 3390
For the 3390
For the L9438-50 or other, Red/Black set (each 1)
For the L9438-53, or other models
For the L9438-53, or other models
For the 8870-20, LR8431-20, 8430-20
For the 8870-20, LR8431-20, 8430-20
For the 3909 (3443/44/45)
For the DT4220 series
For the DT4250 series
For the DT4280, DT4250 series
For the LR8400-20 series
For the PW3198
For the PW3198
For the MR8880-20
For the MR8875
For the PW3360-20/-21 series
For the RM3548
For the LR8410-20 series
For the FT3432-20
For the FT3432-20
For the LR5051 only
For the CT9691/92/93 series
For the 3390-10 only
For the 3390-10 only
Set model with the CT6590
Set model with the CT6590
Set model with the CT6590
For the DSM-8104/8542
Model name DT4221
Model name DT4222
Model name DT4251
Model name DT4252
Model name DT4253
Model name DT4281
Model name DT4282
For the DT4280s/4250 series
For the DT4280s/4250 series
For the DT4220 series
For the EPR-10B
For the FBR-250 series
For the FBR-250 series
For the FBR-250 series
For the EPR-1FA
Model name FT3432
Model No.
HS-1-100
HS-1-150
HS-1-200
HS-1-300
IM3523
IM3533
IM3533-01
IM3570
IM3590
IM9000
IR4016-20
IR4017-20
IR4018-20
IR4056-20
IR4057-20
L1000
L2000
L2100
L2101
L2102
L2103
L2104
L2105
L2200
L4930
L4931
L4932
L4933
L4934
L4935
L4936
L4937
L9170-10
L9198
L9207-10
L9207-30
L9208
L9217
L9257
L9438-50
L9438-53
L9438-55
L9635-01
L9787
L9787-91
L9788-10
L9788-11
L9788-90
L9788-92
L9790
L9790-01
LR5001-20
LR5011-20
LR5031-20
LR5041-20
LR5042-20
LR5043-20
LR5051-20
LR5091
LR5092-20
LR8400-20
LR8400-21
LR8400-92
LR8400-93
LR8401-20
LR8401-21
LR8402-20
LR8402-21
LR8410-20
LR8410-30
LR8431-20
LR8431-30
LR8500
LR8501
LR8510
LR8511
LR9501
LR9502
LR9503
LR9504
LR9601
LR9602
LR9603
LR9604
LR9611
LR9612
LR9613
LR9621
LR9631
LR9801
LR9802
LR9901
MR8740
MR8741
Name
PageNote
EXTERNAL SHUNT
95
EXTERNAL SHUNT
95
EXTERNAL SHUNT
95
EXTERNAL SHUNT
95
LCR METER
34
LCR METER
34
LCR METER
34
IMPEDANCE ANALYZER
33
CHEMICAL IMPEDANCE ANALYZER
32
EQUIVALENT CIRCUIT ANALYSIS FIRMWARE33
ANALOG MΩ HiTESTER
85
ANALOG MΩ HiTESTER
84
ANALOG MΩ HiTESTER
84
INSULATION TESTER
83
INSULATION TESTER
83
VOLTAGE CORD
58 For the PW3198, 3196
4-TERMINAL PROBE
38 For the IM3590/3570, 3506-10, 3505/06
PIN TYPE LEAD
43 For the BT3562, BT3563
CLIP TYPE LEAD
40 For the RM3544, RM3545 series
PIN TYPE LEAD
40 For the RM3544, RM3545 series
PIN TYPE LEAD
40 For the RM3544, RM3545 series
4-TERMINAL LEAD
40 For the RM3544, RM3545 series
LED COMPARATOR ATTACHMENT
40 For the RM3544, RM3545 series, RM3548
TEST LEAD
51 For the ST5540/41, MR8990
CONNECTION CABLE SET
78 For the DT4280/DT4250 series
EXTENSION CABLE SET
78 For the L4930 (for the DT4280/DT4250 series)
TEST PIN SET
78 For the L4930 (for the DT4280/DT4250 series)
CONTACT PIN SET
78 For the L9207-10, DT4911 (for the DT4280/4250
series)
SMALL ALLIGATOR CLIP SET
78 For the L9207-10, DT4911 (for the DT4280/4250
series)
ALLIGATOR CLIP SET
78 For the L4930 (for the DT4280/DT4250 series)
BUS BAR CLIP SET
78 For the L4930 (for the DT4280/DT4250 series)
MAGNETIC ADAPTER SET
78 For the L4930 (for the DT4280/DT4250 series)
TEST LEAD
50 For the SS7012, 3237 series, 3156
CONNECTION CORD
22 For the 8800 series
TEST LEAD
78 For the DT4280/4250 series, 3256/3280 series,
or other models
TEST LEAD
82 For the 3030-10, 3127-10/3128-10, or other models
TEST LEAD
89 For the 3288, 3287, 3280 series
CONNECTION CORD
23 For the 8800 series, or other models
CONNECTION CORD
19 For the 8205-10, 8206-10, 3154
VOLTAGE CORD
56 For the 3390, 3193-10
VOLTAGE CORD
57 For the PW3360s, 3169s, or other
VOLTAGE CORD
59 For the 3197
VOLTAGE CORD
89 For the 3286-20
TEST LEAD
83 For the IR4050s/4010s, 3454/53, 3154
BREAKER PIN
83 For the L9787 (IR4050/4010 series)
TEST LEAD WITH REMOTE SWITCH (RED) 83 For the IR4050/4010 series
TEST LEAD SET WITH REMOTE SWITCH 83 For the IR4050/4010 series
TIP PIN
83 For the L9788/-10 (for the IR4050/4010 series)
BREAKER PIN
83 For the L9788-10/-11 (for the IR4050/4010 series)
CONNECTION CORD
22 For the 8800 series
ALLIGATOR CLIP
22 For the L9790 (for the 8800 series)
HUMIDITY LOGGER
31 Model name LR5001
TEMPERATURE LOGGER
30 Model name LR5011
INSTRUMENTATION LOGGER
30 Model name LR5031
VOLTAGE LOGGER (50mV)
29 Model name LR5041
VOLTAGE LOGGER (5V)
29 Model name LR5042
VOLTAGE LOGGER (50V)
29 Model name LR5043
CLAMP LOGGER
29 Model name LR5051
COMMUNICATION ADAPTER
28
DATA COLLECTOR
28
MEMORY HiLOGGER
26 English model
MEMORY HiLOGGER
-- Chinese model
PV POWER VERIFIER
27 Set model
PV POWER VERIFIER
27 Set model
MEMORY HiLOGGER
26 English model
MEMORY HiLOGGER
-- Chinese model
MEMORY HiLOGGER
26 English model
MEMORY HiLOGGER
-- Chinese model
WIRELESS LOGGING STATION
25 English model
WIRELESS LOGGING STATION
-- Chinese model
MEMORY HiLOGGER
24 English model
MEMORY HiLOGGER
-- Chinese model
VOLTAGE/TEMP UNIT
26 For the LR8400-20 series
UNIVERSAL UNIT
26 For the LR8400-20 series
WIRELESS VOLTAGE/TEMP UNIT
25 For the LR8410-20 series
WIRELESS UNIVERSAL UNIT
25 For the LR8410-20 series
HUMIDITY SENSOR
31 For the LR5001
HUMIDITY SENSOR
31 For the LR5001
HUMIDITY SENSOR
31 For the LR5001
HUMIDITY SENSOR
31 For the LR5001
TEMPERATURE SENSOR
30 For the LR5011
TEMPERATURE SENSOR
30 For the LR5011
TEMPERATURE SENSOR
30 For the LR5011
TEMPERATURE SENSOR
30 For the LR5011
TEMPERATURE SENSOR
30 For the LR5011
TEMPERATURE SENSOR
30 For the LR5011
TEMPERATURE SENSOR
30 For the LR5011
TEMPERATURE SENSOR
30 For the LR5011
TEMPERATURE SENSOR
30 For the LR5011
CONNECTION CABLE
30 For the LR5031
CONNECTION CABLE
29 For the LR5040 series
WALL-MOUNTED HOLDER
28 For the LR5000 series (cannot use with the LR5051)
MEMORY HiCORDER
19
MEMORY HiCORDER
19
Other
9783
CARRYING CASE
9784
DC POWER UNIT
9790-02
GRABBER CLIP
9790-03
CONTACT PIN
9791
MOTOR TESTING OPTION
9792
D/A OUTPUT OPTION
9793
MOTOR TESTING & D/A OUTPUT OPTION
9794
CARRYING CASE
9804
MAGNETIC ADAPTER
9804-01
MAGNETIC ADAPTER
9804-02
MAGNETIC ADAPTER
9809
PROTECTION SHEET
9812
SOFT CASE
9830
PC CARD 2G
AC ADAPTER
PAC-10
BT3562
BATTERY HiTESTER
BT3562-01 BATTERY HiTESTER
BT3563
BATTERY HiTESTER
BT3563-01 BATTERY HiTESTER
C0200
CARRYING CASE
C0201
CARRYING CASE
C0202
CARRYING CASE
C1000
CARRYING CASE
C1001
CARRYING CASE
C1002
CARRYING CASE
C1003
CARRYING CASE
C1004
CARRYING CASE
C1005
CARRYING CASE
C1006
CARRYING CASE
C1007
CARRYING CASE
CC-98A
AC MONITOR OUTPUT CABLE
CC-98D
DC OUTPUT CABLE
CT-5MRN100 CURRENT TRANSFORMER
CT-5MRN120 CURRENT TRANSFORMER
CT-5MRN150 CURRENT TRANSFORMER
CT6500
CLAMP ON SENSOR
CT6590
SENSOR UNIT
CT6862
AC/DC CURRENT SENSOR
CT6862-10 AC/DC CURRENT SENSOR
CT6863
AC/DC CURRENT SENSOR
CT6863-10 AC/DC CURRENT SENSOR
CT6865
AC/DC CURRENT SENSOR
CT9667
FLEXIBLE CLAMP ON SENSOR
CT9691
CLAMP ON AC/DC SENSOR
CT9691-90 CLAMP ON AC/DC SENSOR
CT9692
CLAMP ON AC/DC SENSOR
CT9692-90 CLAMP ON AC/DC SENSOR
CT9693
CLAMP ON AC/DC SENSOR
CT9693-90 CLAMP ON AC/DC SENSOR
DSM-8104 DIGITAL SUPER MEGOHMMETER
DSM-8542 DIGITAL SUPER MEGOHMMETER
DSM8104F Interlock Connection Cable
DT4221-20 DIGITAL MULTIMETER
DT4222-20 DIGITAL MULTIMETER
DT4251-20 DIGITAL MULTIMETER
DT4252-20 DIGITAL MULTIMETER
DT4253-20 DIGITAL MULTIMETER
DT4281-20 DIGITAL MULTIMETER
DT4282-20 DIGITAL MULTIMETER
DT4900-01 COMMUNICATION PACKAGE (USB)
DT4910
THERMOCOUPLES(K)
DT4911
TEST LEAD
F-104
INK PEN
FB-1RD
FELT PEN (RED)
FB-2GN
FELT PEN (GREEN)
FB-3BE
FELT PEN (BLUE)
FR-RD
INK PEN
FT3405
TACHO HiTESTER
FT3406
TACHO HiTESTER
FT3432-20 SOUND LEVEL METER
FT3470-51 MAGNETIC FIELD HiTESTER
FT3470-52 MAGNETIC FIELD HiTESTER
FT3700-20 INFRARED THERMOMETER
FT3701-20 INFRARED THERMOMETER
FT6380
CLAMP ON EARTH TESTER
FT6381
CLAMP ON EARTH TESTER
HS-1-30
EXTERNAL SHUNT
HS-1-50
EXTERNAL SHUNT
HS-1-75
EXTERNAL SHUNT
PageNote
Note: P marked products are discontinued models.
99
Model No. Index
Model No.
Name
PageNote
Other
MR8847-01 MEMORY HiCORDER
18
MR8847-02 MEMORY HiCORDER
18
MR8847-03 MEMORY HiCORDER
18
MR8875
MEMORY HiCORDER
16
MR8880-20 MEMORY HiCORDER
16 English model
MR8880-21 MEMORY HiCORDER
-- Chinese model
MR8901
ANALOG UNIT
16 For the MR8875
MR8902
VOLTAGE/TEMP UNIT
16 For the MR8875
MR8903
STRAIN UNIT
16 For the MR8875
MR8904
CAN UNIT
16 For the MR8875
MR8990
DIGITAL VOLTMETER UNIT
50 For the MR8740/8741
MR9000
PRINTER UNIT
16 For the MR8880-20
MR9321
LOGIC PROBE
22 For the 8800 series
MR9321-01 LOGIC PROBE
22 For the 8800 series
P-1101
RIBBON CASSETTE
-- For the INR9000 series
P-1201A
FELT PEN (RED)
20 For the PR8111, INR-9000, EPR-3000 series
P-1201B
FELT PEN (RED)
-- For the INR-9000, EPR-3000 series
P-1201C
FELT PEN (RED)
-- For the INR-9000, EPR-3000 series
P-1202A
FELT PEN (GREEN)
20 For the PR8111, INR-9000, EPR-3000 series
P-1202C
FELT PEN (GREEN)
-- For the INR-9000, EPR-3000 series
P-1203A
FELT PEN (BLUE)
20 For the PR8111, INR-9000, EPR-3000 series
P-1203C
FELT PEN (BLUE)
-- For the INR-9000, EPR-3000 series
P-1204A
FELT PEN (BROWN)
-- For the INR-9000, EPR-3000 series
P-1205A
FELT PEN (BLACK)
-- For the INR-9000 series
P-1206A
FELT PEN (PURPLE)
-- For the INR-9000 series
P-1207A
FELT PEN (ORANGE)
-- For the INR-9000 series
P-1208A
FELT PEN (PINK)
-- For the INR-9000 series
P-1209A
FELT PEN (PURPLE-BLUE)
-- For the INR-9000 series
P-1210A
-- For the INR-9000 series
P-1211A
-- For the INR-9000 series
P-1212A
-- For the INR-9000 series
PR-1RD
SOFTPEN (RED)
-- For the EPR-151/152/131/132/133
PR-2GN
-- For the EPR-151/152/131/132/133
PR8111
PEN RECORDER
20
PR8112
PEN RECORDER
20
PSU-8541 POWER SUPPLY UNIT
46 For the DSM-8542
PW3198
POWER QUALITY ANALYZER
58
PW3198-90 POWER QUALITY ANALYZER
58 Set model with the 9624-50 PQA-HiVIEW PRO
PW3336
POWER METER
60
PW3336-01 POWER METER
60
PW3336-02 POWER METER
60
PW3336-03 POWER METER
60
PW3337
POWER METER
60
PW3337-01 POWER METER
60
PW3337-02 POWER METER
60
PW3337-03 POWER METER
60
PW3360-20 CLAMP ON POWER LOGGER
57 English model
PW3360-21 CLAMP ON POWER LOGGER
57 English model
PW3360-30 CLAMP ON POWER LOGGER
-- Chinese model
PW3360-31 CLAMP ON POWER LOGGER
-- Chinese model
PW9000
WIRING ADAPTER
58 For the PW3198, 3196
PW9001
WIRING ADAPTER
58 For the PW3198, 3196
PW9002
BATTERY SET
57 For the PW3360-20 series
PW9003
VOLTAGE LINE POWER ADAPTER
57 For the PW3360-20 series
PW9005
GPS BOX
58 For the PW3198
DC Output (1/R)
47 For the SM-8220/16/15/13
PRI-8000
RM3542
RESISTANCE HiTESTER
41
RM3542-01 RESISTANCE HiTESTER
41
RM3543
RESISTANCE HiTESTER
41
RM3543-01 RESISTANCE HiTESTER
41
RM3544
RESISTANCE METER
40
RM3544-01 RESISTANCE METER
40
RM3545
RESISTANCE METER
39
RM3545-01 RESISTANCE METER
39
RM3545-02 RESISTANCE METER
39
RM3548
RESISTANCE METER
39
DC Output (Resistivity-Proportional Output) 47 For the SM-8220/16/15/13
PRP-8000
SE-10
RECORDING PAPER
20 For the PR8111/12, EPR-3500 series, EPR-10B
SE-10Z-2
RECORDING PAPER
20 For the PR8111/12, EPR-3500 series, EPR-10B
SF-10CXZ-35 RECORDING PAPER
-- For the INR-9000
SF-10PXZ-45 RECORDING PAPER
-- For the PRR-5000
SF1001
POWER LOGGER VIEWER
57 For the PW3360-20 series
SG-10X
RECORDING PAPER
-- For the FBR-250 series
SG-10Z
RECORDING PAPER
-- For the FBR-250 series
SH-OZ-T1 RECORDING PAPER
-- For the PSR-2101
SM-8213
SUPER MEGOHMMETER
47
SM-8215
SUPER MEGOHMMETER
47
SM-8220
ULTRA MEGOHMMETER
47
SM7810
SUPER MΩ HiTESTER
45
SM7810-20 SUPER MΩ HiTESTER
45 For 220V power supplies only
SM7860-01 POWER SOURCE UNIT
45
SM7860-02 POWER SOURCE UNIT
45
SM7860-03 POWER SOURCE UNIT
45
SM7860-04 POWER SOURCE UNIT
45
SM7860-05 POWER SOURCE UNIT
45
SM7860-06 POWER SOURCE UNIT
45
SM7860-07 POWER SOURCE UNIT
45
SM7860-21 POWER SOURCE UNIT
45
SM7860-22 POWER SOURCE UNIT
45
SM7860-23 POWER SOURCE UNIT
45
SM7860-24 POWER SOURCE UNIT
45
SM7860-25 POWER SOURCE UNIT
45
SM7860-26 POWER SOURCE UNIT
45
SM7860-27 POWER SOURCE UNIT
45
SM9001 SURFACE/VOLUME RESISTANCE MEASUREMENT ELECTRODE 48 For the SM-8200 series
SM9002 VERIFICATION FIXTURE FOR SURFACE RESISTANCE MEASUREMENT
48 For the SM9001 (for the SM-8200 series)
100
Model No.
Name
Note: P marked products are discontinued models.
PageNote
SME-8301 SURFACE RESISTANCE MEASUREMENT ELECTRODE48
SME-8302 ELECTRODE FOR SURFACE RESISTANCE 48
SME-8310 PLATE SAMPLE ELECTRODE
48
SME-8311 ELECTRODE FOR FLAT SAMPLE
48
SME-8320 WEIGHT ELECTRODE
48
SME-8330 LIQUID SAMPLE ELECTRODE
48
SME-8350 SHIELDING BOX
48
SME-8360 ELECTRODE FOR CHIP CAPACITOR
48
SR-2
STANDARD RESISTOR
48
SS7012
DC SIGNAL SOURCE
50
SS9000
COMMUNICATION PACKAGE
50 For the SS7012
ST-80
73 For the FT3432-20, 3431
ST-80-100
73 For the FT3432-20, 3431
ST5540
LEAK CURRENT HiTESTER
51
ST5541
LEAK CURRENT HiTESTER
51
TM6101
LED OPTICAL METER
69
Z1000
BATTERY PACK
16 For the MR8880-20, LR8400-20 series
Z1002
AC ADAPTER
16 For the MR8880-20 series, MR8875, PW3198
Z1003
BATTERY PACK
16 For the MR8875, PW3198
Z1004
AC ADAPTER
75 For the FT3406
Z1005
AC ADAPTER
17 For the 8870-20, LR8431-20, 8430 series
Z1006
AC ADAPTER
57 For the PW3360-20 series
Z1007
BATTERY PACK
25 For the LR8410-20 series
Z1008
AC ADAPTER
25 For the LR8410-20 series
Z1009
FIXED STAND
25 For the LR8410-20 series
Z2000
HUMIDITY SENSOR
26 For the LR8400-20 series
Z2001
TEMPERATURE SENSOR
40 For the RM3544, RM3545 series
Z2002
TEMPERATURE SENSOR
39 For the RM3548
Z3000
GP-IB INTERFACE
34 For the IM3523, IM3533 series
Z3001
RS-232C INTERFACE
34 For the IM3523, IM3533 series
Z3002
LAN INTERFACE
34 For the IM3523, IM3533 series
Z4001
SD MEMORY CARD 2GB
58
Z5000
FIXED STAND
26 For the LR8400-20 series
Z5003
CONTACT ADAPTER
75 For the FT3405, FT3406
Z5004
MAGNETIC STRAP
28 For the LR5000, DT4281 series
HIOKI Product Warranties
HIOKI’s approach to product warranties is described below.
Product Warr anties
C alibration Frequency
HIOKI’s product warranty extends for a period of one year from the date
of purchase. (If the date of purchase is unknown, the warranty extends
for a period of one year from the date of manufacture.) During this period, HIOKI will repair or replace free of charge any product suffering from
a malfunction deemed to be the manufacturer’s responsibility. Products
labeled as having a three-year warranty are covered for a period of three
years from the date of purchase (or if the date of purchase is unknown,
a period of three years from the date of manufacture).
Calibration is required to verify whether products are able to make
measurements within the defined accuracy. We believe it is important
for customers to determine an appropriate calibration frequency based
on their operating environment and the importance of the measurements being made. HIOKI provides a guaranteed accuracy period on
a product-by-product basis that is intended to serve as a suggested
calibration frequency.
S ervice Period
Warr anty Scope
HIOKI products’ specifications, performance, and functionality are verified
on a product-by-product basis. While we verify proper operation of products that are connected in a standard manner, we ask the customer to do
so themselves when connecting HIOKI products to other companies’ products. HIOKI is only able to cover HIOKI products with its product warranty,
the scope of which does not extend to connected devices or the results
of connected devices. In the event of an issue, HIOKI will repair or replace
free of charge affected HIOKI products. Claims seeking compensation for
property damage are limited to the product’s purchase price.
Accuracy Guar antee Per io d
Products with explicit guaranteed accuracy periods are guaranteed
to perform to the accuracy advertised in their specifications for the
indicated period of time after their shipment from our factory. In the
event you experience an accuracy anomaly during that period, HIOKI
will adjust the instrument free of charge. This offer of free-of-charge
adjustment is limited to the first accuracy anomaly to occur during the
guaranteed accuracy period after shipment of the product.
HIOKI reserves the right to improve products and change models without notice in order to strengthen product competitiveness and improve
productivity. We endeavor to aside a supply of spare parts for discontinued products to ensure that they can be repaired for a minimum of
five years following the cessation of production. When it is difficult to
do so for reasons stemming from social or economic conditions, we
may recommend that customers switch to an alternative model.
Inspection and C alib ration S e r v i c e
We will offer inspection and calibration service for discontinued products as long as we are able to do this work at our facilities. Please
contact your HIOKI distributor for more information about inspection,
repair, or calibration service.
n Traceability
l HIOKI Traceability
HIOKI manages standards, extending from reference
standards shown in the figure to the right to those
used in adjustment, testing, and calibration during
the production process, by means of an integrated
system to ensure traceability back to national and
international standards.
Other
101
HIOKI's Calibration System
By regularly calibrating Hioki instruments using reference calibrating
customers regularly re-calibrate their Hioki instruments to maintain their
equipment traceable to national standards while complying with the
accuracy. Depending on your needs, calibration and adjustment can
reference equipment organizational chart, customers are guaranteed
be conducted at Hioki in one of 3 ways as illustrated below.
complete accuracy. After purchase, it is highly recommended that
Other
102
Sales and Service Structure
Internet website
http://www.hioki.com/
HIOKI’s Worldwide Sales and Service Network
A Global Sales Network
HIOKI has been working to build a sales network supporting world markets in order to globalize its businesses.
Following up on the establishment of HIOKI USA Corporation in the United States in 1998, we have continued to
expand to local markets by establishing sales companies in China, India, and Singapore. In 2012, we established
to users of our automated test equipment products in South Korea.
HEADQUARTERS
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562
FAX +81-268-28-0568
http://www.hioki.com/
E-mail: [email protected]
★ HIOKI USA CORPORATION
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 FAX +1-609-409-9108
http://www.hiokiusa.com/
E-mail: [email protected]
★ HIOKI INDIA PRIVATE LIMITED
201, Radisson Suites, B-Block, Gurgaon, 122 001,
(Haryana)
TEL: +91-124-6590210 FAX: +91-124-6460113
E-mail: [email protected]
Indore Office
Khandela House, 24, Gulmohar Colony, Indore, 542 018
(M.P.)
TEL: +91-731-6548081 FAX: +91-731-4202083
E-mail: [email protected]
★ HIOKI (Shanghai) SALES & TRADING CO., LTD.
1608-1610, Shanghai Times Square Office
93 Huaihai Zhong Road Shanghai, P.R.China
POSTCODE: 200021
TEL: +86-21-63910090 / 63910092
FAX: +86-21-63910360 E-mail: [email protected]
Beijing Office
Unit808,taikang Finacial Tower, No38 Dong San Huan Bei
Road, Chaoyang, District, Beijing
POSTCODE: 100026
TEL: +86-10-8587-9168 FAX: +86-10-8587-9101
E-mail: [email protected]
Guangzhou Office
Room A-3206, Victory Plaza Services Center 103 Tiyuxi
Road, Guangzhou, P.R.China
POSTCODE: 510620
TEL: +86-20-38392673 / 38392676
FAX: +86-20-38392679 E-mail: [email protected]
Mumbai Office
B-303, Knox Plaza, 3rd Floor, Mind Space, Off Malad Link
Road, Malad (W), Mumbai 400 064 (Mah.), India
TEL: +91-22-65346468
E-mail: [email protected]
★ HIOKI SINGAPORE PTE. LTD.
33 Ubi Avenue 3, #03-02 Vertex, Singapore 408868
TEL: +65-6634-7677 FAX: +65-6634-7477
E-mail: [email protected]
Thailand Office
444 2nd Floor Olympia Thai Plaza, Ratchadapisak Rd.,
Samsennok, Huaykwang, Bangkok 10310
TEL/FAX: +66-2-541-5257
E-mail: [email protected]g
Shenzhen Office
Room 1922 Top Office, Glittery City, NO.3027 Shennan
Road Central, Shenzhen, P.R.China.
POSTCODE: 518033
TEL: +86-755-83038357 FAX: +86-755-83039160
E-mail: [email protected]
Suzhou Office
Shi Shan Road, New District, Suzhou, Jiangsu Province,
P.R. China
POSTCODE: 215011
TEL: +86-512-6632-4382/4383 FAX: +86-512-6632-4381
E-mail: [email protected]
Tianjin Office
17C/ B, No.59, International Economy Trade Center
Machang Road, HeXi District, City of Tianjin
POSTCODE: 300203
TEL: +86-022-58581054 FAX: +86-010-58674090
E-mail: [email protected]
Indonesia Office
Menara Kadin 30/F
Jl. HR Rasuna Said Block X-5 Kav 2-3 Jakarta 12950,
Indonesia
TEL: +62-21-5299-4559 FAX: +62-21-52-4599
E-mail: [email protected]
★ HIOKI E. E. CORPORATION
Seoul Representative Office
Rm# 1118 & 1119, 11th floor, East Tower, Hanshin Intervalley 24,322, Teheran-ro, Gangnam-gu, Seoul, 135-918, Rep.
of Korea
TEL: +82-2-2183-8847
DISTRIBUTED BY
■ All information correct as of Dec. 27, 2013.
■ Company names and Product names appearing in this catalog are trademarks or registered trademarks of
various companies.
■ All specifications are subject to change without notice.
This brochure has been
printed with vegetable oil ink.
0001E52-3ZE-15K
Printed in Japan
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement