Daniel™ 1200
Datasheet
January 2013
Daniel 1200
™
Liquid Turbine Flow Meter
Liquid Turbine Flow Meter
Datasheet
Advanced Functionality for Sustained Performance
Overview
The Daniel 1200 Liquid Turbine Flow Meter is a volumetric
flow metering and transmitting device, used extensively in the
petroleum industry for the accurate measurement of liquid
hydrocarbons. It is specifically designed for marketing terminal
and fuel blending service where repeatability is a critical
requirement.
The meter's proven design of lightweight internals is ideally
suited for load rack and terminal applications. Its simple
configuration and self-cleaning, flow-through bearing design
assure high flow rates, extended flow range and sustained
accuracy, with superior repeatability and unmatched reliability.
Typical Applications
ƒƒ Refined products loading / unloading
ƒƒ Batch / blending operations
Features and Benefits
ƒƒ Output linear with flow rate
ƒƒ Rangeability of 10 to 1
ƒƒ Horizontal or vertical installation
ƒƒ Available in 1 to 4-inch line sizes
ƒƒ Superior accuracy and repeatability
ƒƒ High frequency pulse resolution
The 1200 Turbine Flow Meter is versatile and operates in both
horizontal and vertical installations, allowing for installation
in space-constrained applications. It features an expanding
hanger suspension system, offering upstream and downstream
support as well as positive rotor centering.
ƒƒ Uniform pulse signal output
The1200 turbine meter has an integral flow conditioning plate
as a standard feature for sizes 1.5 inch and larger, which has
been proven to greatly reduce or even eliminate the need for
the traditional flow conditioning methods normally used with
turbine meters.
ƒƒ Simple, easy to maintain, field mountable pick-offs
require no interruption of conduit lines
This meter is designed for use within the guidelines of API
Standards, Chapter 5.3 (Measurement of Liquid Hydrocarbon
by Turbine Meter) and the calibration procedures of API,
Chapter 4 (Proving Systems).
ƒƒ Universal Mounting Box (UMB) housing dual-channel
preamplifier and 2 pick-offs
ƒƒ Improved serviceability allows easy access to pick-offs
and reduces installation costs
ƒƒ Explosion proof / weather proof housing
ƒƒ Optional Teflon coated rotors for reduced buildup
ƒƒ Integral flow conditioner
Figure 1: Daniel 1200 Turbine Flow Meter
Page 1
Daniel 1200
January 2013
Standard Specifications (1)
Meter Performance
Electrical Performance
Sizes
Pickoff Specifications
ƒƒ Type: 2-wire reluctance
1", 1.5" and 2"
ƒƒ Resistance: 600 - 900 ohms
ƒƒ Linearity: ± 0.25%
ƒƒ Inductance: 250 mH max
ƒƒ Premium Linearity: ±0.15%
ƒƒ Output: Sinusoidal 40 mV p-p minimum @minimum
flow with preamplifier load
ƒƒ Repeatability: ± 0.02%
3" and 4"
ƒƒ Optional: 2 pick-off coils
ƒƒ Linearity: ± 0.15%
Preamplifier Performance (Dual Channel)
ƒƒ Repeatability: ± 0.02%
ƒƒ Input supply voltage: 10 - 30 V dc
Process Parameters
ƒƒ Minimum input signal amplitude: 40 mV p-p minimum
Table 1: Temperature Ratings
Powered Pulse Output
Carbon Steel
Stainless Steel
ƒƒ Output: 0 to 5 V square wave
-29°C to 82°C
-40°C to 82°C
ƒƒ Frequency range: 0 to 5 kHz
(-20°F to 180°F)
(-40°F to 180°F)
Table 2: Pressure Ratings(3)
ƒƒ Loading: 1 kilohm internal pull-up
Variable Voltage Output
ƒƒ Output: 0 to supply voltage square wave
Size (Inches)
ANSI Class
Carbon Steel
Stainless Steel
1 to 4
150
285 PSI
275 psi
ƒƒ Frequency range: 0 to 5 kHz
1 to 4
300
740 psi
720 psi
ƒƒ Loading: 1 kilohm internal pull-up
Hazardous Area Classifications(2)
Open Collector Output
ƒƒ Output: square wave
ƒƒ UL / C-UL Class 1, Division 1, Groups C&D
ƒƒ Frequency range: 0 to 5 kHz
ƒƒ CE certified Ex d IIB T6 (ATEX)
ƒƒ Maximum voltage: 30 V dc
ƒƒ NEMA 4 (exceeds IP66)
ƒƒ Maximum current: 125 mA
ƒƒ Maximum power: 0.5 W
(1) Please consult Daniel if your requirements are outside the list specifications. Improved performance, other product and material offerings may be available.
(2) The Daniel 1200 Turbine flow meter meets US, Canadian and European industry standards for electrical and intrinsic safety certifications and approvals. Please consult
Daniel for a complete list of agencies and certifications.
(3) Max Pressure in PSI @ 38°C (100°F).
Page 2
Liquid Turbine Flow Meter
Datasheet
Standard Flow Ranges
Table 3: Flow Rate
M3/Hr
BBL/Hr
Size
Standard Flow Range
(Inches)
Min
Max
Extended Max
Flow Range (1)
99
Standard Flow Range
USGPM
Min
Max
Extended Max
Flow Range (1)
1.36
13.6
16
Standard Flow Range
Min
Max
Extended Max
Flow Range (1)
6
60
69
1
8.6
86
1.5
18.6
186
214
2.95
29.5
34
13
130
150
2
31.4
314
361
5.00
50.0
58
22
220
253
3
93
929
1,068
14.8
148
170
65
650
748
4
143
1,429
1,785
22.7
227
284
100
1,000
1,250
Table 4: Linearity
Size (Inches)
Standard Linearity
Premium Linearity
1
+/-0.25%
N/A
1.5
+/-0.25%
+/-0.15%
2
+/-0.25%
+/-0.15%
3
+/-0.15%
N/A
4
+/-0.15%
N/A
Table 5: Nominal K- factor
Size
(Inches)
Pulses/BBL
Pulses/M3
K-Factor
Pulses/US Gal
1
33,600
211,338
800
1.5
16,800
105,669
400
2
7,560
47,551
180
3
2,184
13,737
52
4
966
6,076
23
(1) Extended max range suitable up to 20% of duty cycle not to exceed 2 hours per day.
Page 3
Daniel 1200
January 2013
Product Diagrams
Electrical
DUAL CHANNEL PREAMP
TERMINAL IDENTIFICATION
CUSTOMER CONNECTIONS
White
Pickoff
Black or Red
Channel A
1
TB2
2
J1
Common
J3
Channel B Output
Common
Channel A Output
+10 To 30 VDC
TB1 1 2 3
Table 4: Preamp Jumper Configurations
4 5
J4
TB3
2
1
Black or Red
Pickoff
White
J2
A
N/A
N/A
5V.PULSE
5V.PULSE
A
B
Out
J1-Chan. A Input
J2-Chan. B Input
NA
NA
40 mV. PP Min
40 mV. PP Min
NA
NA
J3-Chan. A Output
J4-Chan. B Output
5 V Pulse
5 V Pulse
Sup. Volt. Pulse (10-30 V dc)
Sup. Volt. Pulse (10-30 V dc)
O.C.
O.C.
Channel B
Figure 2: Dual Channel Preamp
Terminal
PREAMP
JUMPER Identification
CONFIGURATIONS
Customer Connections JUMPER POSITIONS
JUMPER
J1-CHAN. A INPUT
J1-CHAN. B INPUT
J3-CHAN. A OUTPUT
J4-CHAN. B OUTPUT
Jumper
B
40mV. PP MIN
40mV. PP MIN
SUP. VOLT. PULSE (10-30 VDC)
SUP. VOLT. PULSE (10-30 VDC)
OUT
N/A
N/AUMB
O.C.
O.C.
Cover
Gasket
Meter Assembly
Dual Channel
Pre-amplifer
Pickoffs
UMB Housing
O-ring
Hanger
Blades
Shaft
Sleeve
Outlet
Diffuser
Cap
Flow Conditioning Plate
Hanger
Hub
Thrust
Washer
Rotor
Assembly
with
Bearing
Thrust
Washer
Figure 3: Daniel 1200 Turbine Flow Meter Shown with Tungsten Carbide Bearings
Page 4
Liquid Turbine Flow Meter
Datasheet
Materials of Construction
Table 5A: Meter with Stainless Steel Bearing (1" to 4")
Description
Meter Body and Flanges
1" to 1.5"
2" to 4"
Universal Mounting Box (UMB)
Rotor Hub/ Rotor Blades
1" to 1.5"
2" to 4"
Retaining Ring
1" to 1.5"
2" to 4"
Bearing Spacer
1" to 2"
3" to 4"
Shaft
1"
1.5" to 2"
3"
4"
Bearing Set
Suspension Blade
1"
1.5" to 4"
Suspension Diffuser
1"
1.5" to 4"
Downstream Cone
1"
1.5" to 4"
Sleeve
1"
1.5" to 4"
Flow Conditioning Plate
1"
1.5" to 2"
3" to 4"
Standard
NACE MR0175:2002 Compliant
304SS Only
Carbon Steel or 304SS
Aluminum 356-T6
304SS Only
Carbon Steel or 304SS
Aluminum 356-T6
17-4PH
Aluminum 6061-T6 / 430SS
316SS
Aluminum 6061-T6 / 430SS
302SS
302SS
302SS
302SS
303SS
304SS
Aluminum 6061-T6
Aluminum 2011-T3
Stainless Steel
303SS
304SS
Aluminum 6061-T6
Aluminum 2011-T3
Stainless Steel
304SS
Aluminum 2024-T3
304SS
Aluminum 2024-T3
316SS
Aluminum 6061-T6
316SS
Aluminum 6061-T6
303SS
303SS
304SS
304SS
Delrin
Delrin/ Aluminum
NA
Aluminum
Table 5B: Meter with Tungsten Carbide Bearings (3" to 4")
Meter Body and Flanges
Universal Mounting Box (UMB)
Rotor Hub / Rotor Blades
Shaft
Bearing Set
Suspension Blade
Suspension Diffuser
Diffuser Washer
Flow Conditioning Plate
Carbon Steel or 304SS
Aluminum 356-T6 / 316 SS
Aluminum 6061-T6 / 430SS
303SS
Tungsten Carbide
Aluminum 2024-T3
Aluminum 6061-T6
Aluminum 6061-T6
Delrin / Aluminum
Carbon Steel or 304SS
Aluminum 356-T6 / 316 SS
Aluminum 6061-T6 / 430SS
303SS
Tungsten Carbide
Aluminum 2024-T3
Aluminum 6061-T6
Aluminum 6061-T6
Aluminum
Page 5
Daniel 1200
January 2013
Weights and Dimensions
Table 6: Daniel 1200 Liquid Turbine Flow Meter and Flow Straightening Sections
Size
A
B
C
D
E
F
G
(Inches)
Inches
mm
Inches
mm
Inches
mm
Inches
mm
Inches
mm
Inches
mm
Inches
1
8
203
4
102
6.75
171
5
127
5
127
18
457
5
mm
127
1.5
9
229
4.5
114
7
178
7.5
191
7.5
191
24
610
5.75
146
2
9
229
4.5
114
7.25
184
10
254
10
254
29
737
6
152
3
10
254
3.88
98
7.25
184
15
381
15
381
40
1,016
6.5
165
4
12
305
4.5
114
8.25
210
20
508
20
508
52
1,321
7
178
Table 7: Approximate Shipping Weight
ANSI Class 150
ANSI Class 300
Size
(Inches)
lbs
Kg
lbs
Kg
1
13
5.9
13
5.9
1.5
16
7.2
22
10
2
20
9.1
22
10
3
32
14.5
41
18.6
4
47
21.3
64
29
Page 6
Liquid Turbine Flow Meter
Datasheet
Daniel 1200 Turbine Flow Meter Selection Matrix
T
XX
X
X
X
X
X
X
X
X
X
X
X
X
Device
Series 1200
T
Other Documentation
Standard Flow Range
1" DN25 (6-60 GPM, 8.6-86 BHP, 1.36-13.7 M³/H)
01
A
None
Material Test Report (DOC MTR)
NACE with Material Test Report - Compliant
with MR0175 2002; Special Order for NACE
MR0175 /ISO151 2003 (1" - 4" Sizes)
1.5" DN 40 (13-130 GPM, 18.6-186 BHP, 2.95-29.5 M³/H)
15
C
2" DN50 (22-220 GPM, 31.5-315 BHP, 5-50 M³/H)
02
E
3" DN 80 (65-650 GPM, 93-930 BHP, 14.8-148 M³/H)
03
4" DN100 (100-1000 GPM, 143-1430 BHP, 23-230 M³/H)
04
Approvals / Documentation
Pressure Rating / Flange Type
G
CCA / UL / CUL (3" & 4" Only)
150# ANSI, RF ( 285 psi MWP, 125-250 AARH)
A
J
300# ANSI, RF (740 psi MWP, 125-250 AARH)
B
K
CE (Includes ATEX, PED or SEP and EMC)
DIN 2501 PN16, RF (16 BAR MWP)
P
M
INMETRO
DIN 2501 PN40, RF (40 BAR MWP)
Q
UL / CUL (CSA coverd by UL / CUL)
Linearity
Design Style / Enclosure Style
C
Alum UMB w/ SS Bearings
E
Alum UMB w/ Tungsten Carbide Bearings (3" & 4" Only)
F
D
1" - 2" (+/- 0.25%), 3" & 4" (+/- 0.15%
1" - 2" (+/- 0.15%)
Display Mounting
Meter Output / Temperature Range
A
None
Standard Temperature Range (-29C to 82C)
B
Integral
C
Remote
1 Pick-Off, 1 Dual Channel Preamp
A
2 Pick-Offs, 1 Dual Channel Preamp
D
Display
Metrology Approvals
Unspecified
1
NTEP, CC: 90-118, For 1.5" Meter: 6 - 130 GPM
(For Extended Flow Ranges See Certificate)
2
Measurement Canada, AV-2264, 5:1 Turndown for Diesel Fuel and Stove Oil
3
None
D
MRT-97 Electronic Register
Materials of Construction
Body / Flange / Internals
Relative Density (Specific Gravity) of Calibration Fluid
0.78 - 0.79 Mineral Spirits
A
J
Flow Direction / Flow Conditioning
Horizontal, No Flow Conditioning Plate (1" Only)
A
Vertical, No Flow Conditioning Plate (1" Only)
B
Horizontal, Flow Conditioning Plate (1.5" - 4" Only)
C
Vertical, Flow Conditioning Plate (1.5" - 4" Only/Upward Flow Only)
D
Horizontal, Aluminum Flow Conditioning Plate (3" & 4" Only)
F
Vertical, Aluminum Flow Conditioning Plate (3" & 4" Only/Upward Flow Only)
G
A
CS Body and Flanges, SS/Al/Ball Bearing/Teflon Coated Rotor (2", 3" & 4" Only)
C
CS Body and Flanges, SS/Al/Tungsten Carbide / Teflon Coated Rotor (3" & 4" Only)
4
CS Body and Flanges, SS/Al/Ball Bearing (2", 3" & 4" Only)
9
CS Body and Flanges, SS/Al/Tungsten Carbide (3" & 4" Only)
B
304 SS Body and Flanges, SS/Al/Ball Bearing/Teflon Coated Rotor
D
304 SS Body and Flanges, SS/Al/Tungsten Carbide/Teflon Coated Rotor (3" & 4" Only)
7
304 SS Body and Flanges, SS / Al / Ball Bearing
8
304 SS Body and Flanges, SS / Al / Tungsten Carbide (3" & 4" Only)
Note: Flow Conditioning Plate is not Applicable for the 1" Meter
This is for informational purposes only. Not every option is listed and some options are contingent on others. Please consult factory for
assistance designing your optimal meter.
Page 7
Emerson Process Management
Daniel Measurement and Control, Inc.
North America / Latin America:
Headquarters
USA - Houston, Texas
T +1.713.467.6000
USA Toll Free 1.888.FLOW.001
Europe: Stirling, Scotland, UK
T +44.1786.433400
Middle East, Africa: Dubai, UAE
T +971.4.811.8100
Asia Pacific: Singapore
T +65.6777.8211
www.Daniel.com
©2013 Daniel Measurement and Control, Inc. All Rights Reserved. Unauthorized duplication in
whole or in part is prohibited. Printed in the USA. DAN-LIQ-DS-1200TM-0113
Daniel Measurement and Control, Inc. (“Daniel”) is an Emerson Process Management business
unit. The Daniel name and logo are trademarks of Daniel Industries, Inc. The Emerson logo is a
trademark and service mark of Emerson Electric Co. All other trademarks are the property of their
respective companies.
Scan with your smart
phone for more
information
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement