USYS 20

Add to my manuals
4 Pages

advertisement

USYS 20 | Manualzz

USYS 20

Economic Processor for Diameter or Capacitance

Measurement, Data Acquisition, Processing, Display & Control

2

USYS 20 – Hi-Tech, Industrial Data Acquisition System with a Human Touch

The system features real-time, multi-tasking data processing and control. USYS 20 accepts measurements from a broad line of ZUMBACH gauges covering a diameter or width range from 0.012 mm (0.00047 in.) to 310 mm (12.2 in.) with a selectable resolution of up to 0.00001 mm (0.0000004 in.).

• Complete system for one measuring point

• Simultaneous display of 3 measured values

• Industrial, rugged design

• High-contrast LCD monochrome screen (240 x 128 pixels)

• Alarm displays

• Real-time data collection

• Reel and session reports

• DDC – Direct Dynamic Control system

• SRD – Static Regulating Device

User friendly control panel with easy menu navigation

Heavy duty industrial grade front panel. Membrane covered mechanical switches feature tactile and audio feedback.

Screen

4.2" LCD graphical display with protection glass

Numeric keypad

These keys are used for numeric data entry.

6 bright LED's

Alarm displays

(tolerance, pre-alarm and other limit exceedings), controller (Control)

Select / Enter keys

Clearly marked keys used in connection with systems and product information.

Direct access function keys

Functions and displays frequently used can be called up directly (controller

ON/OFF, nominal, tolerance etc.).

Navigation key Power ON / OFF switch

Flexible Mounting Possibilities

Table top use

Standard

Wall mounting

Using the fastening rails included in the delivery.

Mounting onto a floor stand ST 2

Thanks to a mountable support the

USYS 20 table top unit can easily be added onto a floor stand of the ST 2 series.

19" rack mounting

This 19" drawer allows the mounting of 1 or 2 USYS 20.

By means of the fixation set no. USY.0002.930

By means of the rotary holder no.

USY.0002.910.

Note:

A suitable housing is optionally available (no. A32 100 0330).

By means of the fixation set, no.

USY.0002.920.

Mountable support no. ST02.060.190

Floor stand of the ST 2 series

Rear Panel Inputs, Outputs and Peripherals (Options)

Measuring head connector

One unit from the wide range of digital 1, 2 or 3 axis ODAC ® diameter measuring heads can be connected. Instead of the diameter measuring head, it is also possible to connect a capacitance measuring system of the CAPAC ® J series.

Port 1

Serial interface

Can be configured for the connection with a printer

(Continuous or label printer) or a remote display.

1 axis measuring heads

2 axis measuring heads

3 axis measuring heads

Port 2

Serial interface

For the communication with a higher level host computer or the connection with USYS Data

Log from Zumbach or a remote display

MV3-RK

Motorized vacuum controller

Mains connector/fuse

Integrated connector with built-in fuse and mains filter.

Port 3

Ethernet interface

With TCP/IP protocol for the integration of the USYS 20 into a local network (LAN).

Communication with a higher level host computer or linked with USYS Data Log from Zumbach.

Line speed/footage counter input

Proximity detector or WG 2 or TI 069

Event input

Lumps, neckdowns, spark failures, reel change etc.

Data collection

Start/stop and pause input

Relay output

Offers 3 configurable relay outputs

(e.g. system alarm, tolerance alarm).

It also enables the connection of an external control pulse for the automatic control of the equipment

(e.g. vacuum controller).

I/O connector

Following inputs/outputs are available:

– 4 digital inputs (e.g. statistics, start/stop, pause)

– 5 digital outputs (tolerance alarms, pre-alarms)

– 1 counter input (e.g. for the line speed)

– 1 analog output +/- 10 V

The connections can be extended, by means of the optional Static Regulating Device, with 2 additional digtal inputs and 1 static regulating device (analog input and output).

"SRD" Static Regulating Device

Control of line speed/ extruder screw r.p.m.

MPK1-10T / PS 11130-A

Motorized potentiometer with servo valve for control of internal air support pressure

Chart recorder

(analog)

3

4

USYS Data Log

The USYS Data Log is a Windows TM based software, offering an easy way to configure specific data acquisition (logging and archiving) from ZUMBACH processors onto customer PCs.

The measurement data can be collected from a single instrument or from several ZUMBACH processors and saved in a text file format or in Excel TM . USYS Data Log communicates with the processors through a serial interface or an Ethernet TCP/IP connection.

™ Windows and Excel are trademarks of Microsoft Corporation

SPC

Session

Piece

... up to 10

Multiple Collection

Several USYS Data Log programs can run on the same

PC, i.e. it is possible to collect the information of all

Zumbach processors in the factory to only one single computer .

Dimensions

240 (9.45)

266 (10

.47)

*

* Allow additional space on rear side of 90 mm (3.5")

for connectors.

483 (19.02)

Main Specifications

Electrical power supply

Mains voltage:

Tolerance:

115 V / 230 V~

-10...+ 6 %

Mains frequency:

Power:

48...62 Hz max. 200 VA

Temperature range

Operating: 0...50° C (32 ... 120° F)

Transport / storage: - 20...70° C (-4 ... 140° F)

IP 51 Protection

Weight

Table top version:

19'' rack version:

3.4 kg (7.5 lbs.)

11.5 kg (25 lbs.)

(11.02

)

Dimensions in mm (in.)

Switzerland (H.Q.)

ZUMBACH Electronic AG

P. O. Box

CH-2552 Orpund

Phone +41 (0)32 356 04 00

Fax +41 (0)32 356 04 30

E-mail: [email protected]

USYS 20 meets the current CE standards regarding overall performance and EMC

(Electro Magnetic Compatibility).

USA

ZUMBACH Electronics Corp.

140 Kisco Avenue

Mount Kisco, NY 10549-1407

Phone +1 914 241 7080

Fax +1 914 241 7096

E-mail: [email protected]

• Specifications are subject to change without notice

Other ZUMBACH companies in Argentina,

Belgium, Brazil, China, France, Germany,

India, Italy, Spain, Taiwan and UK, plus agents and service in more than 40 countries.