MCR 515.cdr
Monitoring current relay
MCR 515
! To monitor heating rods in shunts, heating cables, consumption of
one-phase motors, indicates current flow
! Flexible adjustment by potentiometer, choise of 6 ranges:
0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A
.
! Adjustable delay 0.5 - 10 s to eliminate short current peaks
.
! Possible to use current scanning from current transformer - up to 600 A
.
! Universal supply AC 24 - 240 V and DC 24 V
.
! Supply is not galvanically separated from measured current, it must
be in the same phase
.
! Output contact: 1 x changeover 8 A
.
! 1-phase, 1-MODULE, DIN rail mounting
Function
Connection
Example Connection:
MCR 515 with currenttransformer
for current range increase
Symbol
Dimensions
Description
Function description
Monitoring relay MCR 515 serves to monitor current level
in one-phase AC circuits. Gradual setting of actuating
current of monitoring relay enables many different
applications. Output relay is in normal state open. After the
set current level is reached, relay closes after the set delay
(0.5-10 s). When returning from faulty to normal state there
is a hystersis (5 %). Multi-voltage of this relay is an advantage.
It is possible to monitor load which doesn´t have the same
supply as monitoring relay MCR 515. Range of MCR 515
can be increased by an external current transformer.
Efficient installations
Monitoring current relay
MCR 515
Technical data
MCR 515
Supply circuit
Supply terminals
A1 - A2
Supply voltage
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Consumption
max. 1.5 VA
Supply voltage tolerance
-15 % ; + 10 %
Measuring circuit
Load
Current range
Max. permanent current
Inrush overload < 1 ms
Current adjustment
Time delay
between B1 - B2
AC 0.5 - 5 A (applicable also for current transformer)
5A
100 A
potentiometer
adjustable 0.5 -10 s
Accuracy
Setting accuracy (mechanical)
Repeat accuracy
Temperature dependancy
5%
<1 %
<0.1 % / C
Limit values tolerance
5%
Hysteresis (fault to OK)
5%
Output
Number of contacts
Rated current
1 x changeover (AgNi)
8 A / AC1
Breaking capacity
2500 VA/ AC1, 240 W / DC
Output indication
green / red LED
Other information
Operating temperature
Storage temperature
Electrical strenght
Operating position
Mounting
Protection degree
Overvoltage category
Pollution degree
Max. cable size (mm2)
Dimensions
Weight
Standards
-20 ... +55 °C
-30 ... +70 °C
4 kV (supply - output)
any
DIN rail EN 60715
IP 40 from front panel
III.
2
solid wire max. 2x2.5 or 1x4
90 x 17.6 x 64 mm
58 g
EN 60255-6, EN 61010-1