NEMA-4X Family
The industry standard for emergency lighting in harsh environments is here. Battery units,
remote fixtures, exit signage and combination units - Lumacell® is proud to offer a complete
family of NEMA-4X Certified emergency lighting products that delivers impressive, state-ofthe-art illumination in a visually-appealing package.
A complete emergency lighting solution, these products are designed for use in a wide range
of commercial and industrial environments where humidity, dust, water infiltration and the
risk of vandalism are specification criteria.
FEATURES
CERTIFICATIONS
APPLICATIONS
• Battery units and remotes fixtures
deliver unsurpassed pathway
illumination —
89 feet, center-to-center (see
photometric data on back cover)
• Fully gasketed enclosures prevent
water infiltration
• Vandal-resistant enclosures resist dents, peeling and corrosion
• All units come with tamper-proof
screws and bits
• UV resistant enclosures
• Choice of colours - factory white, black
and grey
• Continuous self-diagnostic monitoring
and monthly self-testing
• Fully automatic, solid state charger
• Non-intrusive magnetic test switch
• Nexus® monitoring system optional
• CSA Certified for 30 minutes of
emergency operation
• Exit signs meet or exceed C22.2
No. 141
• NEMA-4X Certified for high abuse
areas, wet locations and cold weather
(-40°C) applications
• NSF Certified for use in food processing
plants
• Hosedown areas/ car washes
• Food processing/ preparation facilities
• Marine locations
• Chemical plants
• Schools and other public facilities
• Parking garages
• Transit platforms
• Sports arenas/ swimming pools
• Security areas/ prisons
• Warehouse and cold storage facilities
• Heavy industrial facilities
NEMA-4X
2
www.lumacell.com
LN SERIES
LNC SERIES
NEMA-4X & NSF Certified Pictogram Sign
NEMA-4X & NSF Certified Combination Unit
• Sealed heavy-duty, vandal-resistant polycarbonate faceplate
• Suitable for cold weather application —
-40°C (AC/DC model) and -25°C on self-powered model
(CW option)
• Energy efficient - consumes less than 2.5W in AC or DC mode
NEMA-4X LN Series
• Same product with exit legend also available
• Innovative, field-adjustable lamp head assembly
• Choice of MR16 halogen lamps up to 12V, 12W or
high-performance, 6W, MR16 LED lamps
• Can be wall or ceiling mounted
• Double face available
• Suitable for cold weather application —
-40°C (CW option) - Available in 6V only.
• Same product with exit legend also available
UNRIVALLED PATHWAY ILLUMINATION
89 FEET CENTER-TO-CENTER
(see photometric data on the last page)
RG-NX SERIES
MQM-HZ SERIES
NEMA-4X Certified Battery Unit
NEMA-4X Certified Remote Fixtures
• Fully gasketed cast aluminium back plate with clear UV resistant
polycarbonate cover
• Long-life maintenance-free sealed Lead-Acid battery
• Choice of MR16 halogen lamps up to 12V, 20W or highperformance, 6W, MR16 LED lamps
• Mounting: wall mount
• Unit capacity: up to 108W
• Suitable for cold weather application —
-40°C (CW option)
• Choice of single or double head models
• Fully gasketed cast aluminium or polycarbonate back plate with
clear UV resistant poly carbonate cover
• Choice of MR16 halogen lamps up to 24V, 20W or highperformance, 6W, MR16 LED lamps
www.lumacell.com
3
Type:
Project/Location:
LN Series
Contractor:
Prepared By:
NEMA-4X rated & NSF
Certified Pictogram Exit
Sign
Date:
Model No.:
FEATURES
TYPICAL SPECIFICATIONS
•NEMA-4X Certified
•NSF compliant for food processing
•Polymeric enclosure is fully gasketed around lens and canopy to secure
Supply and install the Lumacell® LN Series pictogram Exit Signs. The equipment
shall be certified for NEMA- 4X and designed specifically for high abuse areas,
wet location, and cold weather applications. The equipment frame shall be of
industrial grade polyvinyl chloride with a gasket around lenses and canopy. The
faceplate(s) shall be constructed of heavy-duty vandal-resistant polycarbonate
and feature an even illuminated legend. Each face plate shall come standard
with two legend films for pictogram and direction selection. The light source
shall be white light-emitting diodes (LED). The pictogram Exit Sign shall operate
with universal 2-wire AC input voltage of 120 to 347VAC at less than 2.5W and
universal 2-wire DC input voltage from 6 to 24VDC at less than 1 Watt for single
and double face signs. The Self-Powered model shall include a concealed green
pilot light and magnet-sensitive test switch, shall use a sealed Nickel-Cadmium
battery of 2.4V nominal voltage and shall stay illuminated during emergency
operation for 120 minutes upon AC failure. When specified, the Self-Powered
model shall include auto-test functions: it shall execute automatic tests for 5
minutes every 30 days, 30 minutes every 60 days and two hours annually. When
a fault is detected, the bi-colour pilot light shall turn from green to red and flash
following a particular code. The code description shall be visible on a label next to
the pilot light to identify the failure type: battery, charger circuitry, or LED lamps.
The pictogram Exit Sign shall be CSA 22.2 No.141-15 certified.
The equipment shall be Lumacell® Model:
.
against water leaks
•Sealed, heavy-duty, vandal-resistant polycarbonate face plate
•Suitable for cold-weather: -40°C (-4°F) for AC/DC and -20°C (-40°F)
for Self-Powered models (option: -CW)
•Tamper-resistant, concealed test switch with magnetic action
•Long-life white LED light source is warrantied for ten (10) years
•Supplied standard with two pictogram films per face, for direction selection
•Universal AC input: two-wire 120 to 347VAC; standard DC input:
two-wire 6 to 24VDC
•Energy efficient – consumes less than 2.5W in AC or DC-remote mode
•Self-Powered models deliver two hours of back-up lighting
•Meets or exceeds CSA 22.2 No.141-15
See warranty details at: www.tnb.ca/en/brands/lumacell
NEMA-4X
DIMENSIONS
POWER CONSUMPTION AND UNIT RATING
Dimensions are approximate and subject to change.
< PICTOGRAM
LEFT FROM HERE
MODEL
PICTOGRAM
STRAIGHT FROM
HERE
PICTOGRAM >
RIGHT FROM HERE
14” [35.7 cm]
3-7/8” [9.9 cm]
9-1/4” [23.4 cm]
13-1/4” [33.6 cm]
3-1/2” [8.7 cm]
DOUBLE FACE
AC SPECS
DC SPECS
AC-only
120 to 347VAC
Less than 2.5W
-
-
AC/DC standard
120 to 347VAC
Less than 2.5W
6 to 24VDC
Less than 1W
AC/Special DC
120 to 347VAC
Less than 2.5W
36, 48, 120VDC
Less than 2.5W
Two-wire 120V AC/DC
120VAC
Less than 2.5W
120VDC
Less than 2.5W
Self-Powered
120 to 347VAC
Less than 3W
Ni-Cd battery
120 minutes
Auto test
120 / 347VAC
Less than 3.5W
Ni-Cd battery
120 minutes
SINGLE FACE
WIRE GUARDS
460.0079-L
Wall mount
460.0027-L
End mount
460.0028-L
Ceiling mount
ORDERING INFORMATION
SERIES
FACES/ MOUNTING
COLOUR
LN= N
EMA-4X &
NSF pictogram
exit sign
1= s ingle face universal mounting
2= d ouble face universal mounting
B= black
W= factory white
EXAMPLE: LN1BUCW
4
www.lumacell.com
VOLTAGE
S= Self-Powered, 120 to 347VAC
SD= Self-Powered diagnostic Ni-Cd, 120/347VAC
SD2= Self-Powered diagnostic Ni-Cd, 120/277VAC
U= universal 120 to 347VAC; 6 to 24VDC
U00= 120 to 347VAC only
U36= 120 to 347VAC; 36VDC
U48= 120 to 347VAC; 48VDC
U120= 120 to 347VAC; 120VDC
2120= 2-wires 120VAC/VDC
NEX= NEXUS® system interface, 120/347VAC
NEXRF= w
ireless NEXUS® system interface, 120/347VAC
OPTIONS
CW= c old-weather (-20°C for SD, SD2 and
NEXUS® only. -40°C for universal 120 to
347VAC; 6 to 24VDC)
Unlike Exit Signs this pictogram sign is not available in double arrow configuration.
Type:
Type:
Project/Location:
Project/Location:
Contractor:
Contractor:
Prepared By:
Prepared By:
Date:
Date:
Model No.:
Model No.:
LNC Series
NEMA-4X Rated
Pictogram Exit Sign
FEATURES
TYPICAL SPECIFICATIONS
•Certified Nema-4X for wall or ceiling mount
•NSF for use in food processing areas
•Polyvinyl chloride frame, with built-in gasket to prevent water infiltration
•Sealed, vandal-resistant faceplate of polycarbonate
•Legend illuminated by long-life white LED’s is warrantied for 10 years
•Comes standard with two pictogram films per face, for direction selection
•Two high-performance MR16 lamps shielded by a clear polycarbonate
Supply and install Lumacell® LNC Series combination of unit equipment and
pictogram Exit Sign. Designed specifically for the industrial environment, the
equipment frame shall be of industrial grade polyvinyl chloride with gaskets
around both sides of the frame contour. The back plate shall be made of
1/8-inch thick aluminum sheet and shall include knock-outs for installation
on an electrical box. The faceplate(s) shall be constructed of heavy-duty
vandal-resistant clear polycarbonate and feature a uniformly illuminated
pictogram legend. Each face plate shall come standard with two legend films
for pictogram and direction selection. The light source shall be long-life white
light-emitting diodes (LED). The unit shall have attached a lower compartment
containing two emergency heads with adjustable swivels and long-life MR-16
LED lamps of ___ V and ___ W. The heads shall be installed on a shield
housing made of rigid thermoplastic and shall be protected by a shock-absorbent, clear polycarbonate cover.
The standard AC input voltage shall be 120/347VAC. The unit shall be equipped
with a magnetic test switch and a LED pilot light protected by the clear face
plate. The unit shall perform auto-test functions managed by a micro-controller
and shall automatically self-test for one minute every 30 days, 10 minutes in
the 6th month and 30 minutes annually. When a fault is detected, the bi-colour
pilot light shall turn from green to red and flash following a particular code.
The code description shall be displayed on a label next to the pilot light to
identify the failure type: battery, charger circuitry, LED lights for the signage,
or emergency lights.
The combination unit shall be CSA 22.2 No.141-15 certified.
.
The equipment shall be Lumacell® Model:
cover
•Sealed, maintenance-free Lead-Calcium or Nickel-Cadmium batteries
•Remote load capacity: covers with 4W LED lights 100 feet up to 230
feet of egress illumination
•Comes standard with auto-diagnostic
•Cold-weather option: -40°C (-40°F) with only 14W extra power
consumption
•Meets or exceeds CSA 22.2 No.141-15
See warranty details at: www.tnb.ca/en/brands/lumacell
NEMA-4X
DIMENSIONS
Dimensions are approximate and subject to change.
PICTOGRAM >
< PICTOGRAM
PICTOGRAM
RIGHT FROM HERE
LEFT FROM HERE
STRAIGHT FROM HERE
14” [35.7 cm]
3-7/8” [9.9 cm] 3-1/2” [8.7 cm]
13-1/4” [33.6 cm]
POWER CONSUMPTION
MODEL
12-5/8” [32.1 cm]
9-1/4” [23.4 cm]
Pictogram sign
module
AC SPECS
120/347VAC
LNC-6L36
LNC-6L36-CW
SINGLE FACE
DOUBLE FACE
120/347VAC
LNC-12N60
EMERGENCY POWER FOR
LAMPS
30MIN
1H
1H30
2H
4H
Less than
2.5W
-
-
-
-
-
0.10/0.03A
36
30
20
16
8
0.25/0.08A
36
30
20
16
8
0.18/ 0.06A
60
40
30
20
10
WIRE GUARDS WITH HEADS
460.0078-L
Wall Mount
460.0060-L
End or Ceiling Mount
ORDERING INFORMATION
SERIES
LNC= NEMA-4X
& NSF
pictogram exit
combo unit
FACES /
HOUSING
MOUNTING* COLOUR
1= single face
2= double face
* Universal mounting
EXAMPLE: LNC2W12N60LD7
B= black
W= factory
white
BATTERY TYPE
AND POWER
HEAD STYLE AND
POWER
6N36= 6 V-36W, Ni-Cd
12N60= 1 2V-60W, Ni-Cd
Blank= no heads
LD1= MR16 LED, 6V-4W
LD7= MR16 LED, 12V-4W
LD9= MR16 LED, 12V-5W
LD10= MR16 LED, 12V-6W
MI= MR16 halogen, 6V-6W
MJ= MR16 halogen, 6V-10W
MK= MR16 halogen, 12V-12W
Blank= advanced diagnostic non-audible (standard)
ZC= 120/277VAC input
AT= auto-test
NEX= NEXUS® system interface*
NEXRF= w
ireless NEXUS® system interface*
CW= cold-weather -40°C only with 6V single face
T3= time delay (15 minutes)
* Remote load must be connected.
* Some options are not available with NEXUS®.
OPTIONS
Unlike Exit Signs this pictogram sign is not available in double arrow configuration.
www.lumacell.com
5
Type:
Type:
Project/Location:
Project/Location:
Contractor:
Contractor:
Prepared By:
Prepared By:
Date:
Date:
Model No.:
Model No.:
RG-NX Series
RG-NX
Series
NEMA-4X Rated
Rated Certified
Certified
NEMA-4X
FEATURES
TYPICAL SPECIFICATIONS
• Fully gasketed cast aluminum back plate with clear
Supply and install the Lumacell® NEMA-4X Certified RG-NX Series
battery unit. Specifically designed for high abuse areas, wet locations, and
cold weather (CW option -40°C (-40°F)), the housing shall consist of a fully
gasketed die-cast with a cast aluminum back plate and a clear heavy-duty
UV resistant polycarbonate cover. The heads shall be fully adjustable without
tools and the lamps shall be high efficiency halogen MR16. The standard unit
shall be equipped with tamper-proof screws and bits.The Lumacell Advanced
Diagnostic Micro-controller charger board shall supply the rated load for a
minimum of 30 minutes to 87.5% of the rated battery voltage. The charger
incorporates lockout and brownout circuits, and low voltage disconnection.
It protects the unit from over-current, short-circuit, and reverse polarity. The
unit shall be rated 120/347V, 60Hz. The unit shall have an output of
V. This unit shall self-test for 1 minute every 30 days, 10 minutes on the 6th
month and 30 minutes every 12 months. The unit shall be furnished with a
non-intrusive magnetic test switch. A “Service Required” lamp shall be located
near the test switch and flash when a fault is detected. A four-LED diagnostic
display shall be located inside the equipment and shall identify the source of
failure (battery, charger, circuitry,or lamps).
The unit shall be CSA 22.2 No. 141-15 certified.
The unit shall be Lumacell® model:
.
polycarbonate cover – NEMA-4X Certified
• Comes standard with non-audible advanced diagnostic, 10 minute time
delay and lamp disconnect
• Audible warning and time delay functions can be enabled
or disabled during installation
• Micro-controller diagnostic system tests, detects and
indicates battery, charger circuitry or MR16 lamp failures
• Non intrusive magnetic test switch
• Long-life, maintenance-free sealed Lead-Acid battery
• 1/2” rigid conduit entry on top and back
• Can be installed on 4” junction boxes
• Comes standard with tamper-proof screws and bit
• Standard 120/347VAC input voltage
• Cold weather option -40ºC (-40ºF)
• NSF Certified for food processing plants
• Meets or exceeds CSA C22.2 No. 141-15
See warranty details at: www.tnb.ca/en/brands/lumacell
WIRE GUARDS
NEMA-4X
460.0031-L
Wall Mount
ACCESSORIES
Additional bit for tamperproof screws
TPB
Universal bracket (for mounting on poles, I-beams)
PMK
REPLACEMENT LAMPS
ORDERING CODE
TYPE OF SPECIFICATIONS
580.0079-L
M10W, MR16, 6V-10W FL
580.0080-L
M12W, MR16, 12V-12W FL
580.0097-L
MR16 LED, 6V-4W
580.0093-L
MR16 LED, 12V-5W
580.0104-L
MR16 LED, 12V-5W
580.0106-L
MR16 LED, 12V-6W
IN THE SAME FAMILY: NEMA 4X
- LER300 Series
- 3LER300 Series
p. 65
p. 67
- MQM-NX NEMA 4X
Remote Fixtures
p. 149
116
6
www.lumacell.com
www.lumacell.com
Type:
Type:
Project/Location:
Project/Location:
Contractor:
Contractor:
Prepared By:
Prepared By:
Date:
Date:
Model No.:
Model No.:
RG-NX
Series
RG-NX
Series
NEMA-4X
NEMA-4X Rated
Rated Certified
Certified
DIMENSIONS
Dimensions are approximate and subject to change.
5-3/4” [14.6 cm]
17-3/4” [45.1 cm]
7” [17.8 cm]
PMK KIT
(SCREWS INCLUDED)
SUPERSTRUT
MOUNTING
BEAM MOUNTING
POWER CONSUMPTION AND UNIT RATING
MODEL
WATTAGE CAPACITY
AC SPECS
30MIN
1H00
1H30
2H00
RGNX36
0.15/0.06A
36
21
15
12
6
RG12NX72
0.25/0.10A
72
42
30
24
12
0.25/0.10A
108
63
45
36
18
0.45/0.20A
36
-
-
-
-
0.85A
72/108
-
-
-
-
120/347VAC
RG12NX108
Cold Weather 36W
Cold Weather 72/108W
120VAC
4H00
*Note: capacity depends on the ambient temperature
ORDERING INFORMATION
SERIES
CAPACITY
RGNX= 6V, NEMA-4X
RG12NX= 12V,
NEMA-4X
36= 6V-36W
72= 12V-72W
108= 12V-108W
NUMBER
OF HEADS
2= 2 heads
LAMP TYPES AND
WATTAGE
LD1= MR16 LED, 6V-4W*
LD7= MR16 LED, 12V-4W*
LD9= MR16 LED, 12V-5W
LD10= MR16 LED, 12V-6W
M6W= MR16 halogen, 6V-6W
M10W= MR16 mini-halogen,
6V-10W
M12W= MR16 mini-halogen,
12V-12W
M20W= MR16 mini-halogen,
12V-20W
MH20W= MR16-IR, 12V-20W,
high output
* Minimum lamp load required: 20%
of unit capacity.
COLOUR
AC VOLTAGE
Blank= white
BK= black
SG= grey
Blank= 120/347VAC
ZC= 277VAC input
OPTIONS
Blank= no options
NEX= NEXUS® system interface*
NEXRF= wireless NEXUS® system interface*
CW1= cold weather 120VAC
CW3= cold weather 347VAC**
PMK-L= universal bracket (sold separetely)
* Not all options are available with NEXUS® System.
Please consult your sales representative.
** Available in 6V only.
EXAMPLE: RGNX362M6W
www.lumacell.com
www.lumacell.com
117
7
Type:
Type:
Project/Location:
Project/Location:
Contractor:
Contractor:
Prepared By:
Prepared By:
Date:
Date:
Model No.:
Model No.:
MQM-NX
Series
NEMA-4X Certified
Remote Fixture
FEATURES
TYPICAL SPECIFICATIONS
•Fully gasketed with a selection of Die-Cast aluminum or polycarbonate
back plate
•Clear polycarbonate UV and impact resistant lens
•Choice of single or double lamp models
•Available in 6, 12 and 24V models MR16 or LED
•Easy lamp replacement
•Comes standard with tamper-proof screws and bit
•NSF Certified for food processing plants
•NEMA-4X Certified*
•Suitable for indoor/outdoor installation
•CSA Certified to C22.2 No. 141-15
See warranty details at: www.tnb.ca/en/brands/lumacell
Supply and install Lumacell® MQMP Series remote emergency lighting
fixtures. These remote fixtures will consist of either single or double lamp
configurations according to the design. These fixtures shall be fully gasketed
with a UV resistant and fire retardant Die-Cast aluminum or polycarbonate
back plate with a clear heavy-duty UV resistant polycarbonate light cover. The
unit shall be equipped with two emergency heads with tool-less adjustable
swivels (lamps of 12W or less). Units shall be NEMA-4X and NSF certified and
specifically designed for high abuse areas, wet and cold weather locations, food
processing plants as well in applications requiring a resistance to corrosive
agents. The standard unit will come with stainless steel tamper-proof screws
and bit.
The remote fixture shall be certified to CSA C22.2 No. 141-15. The head(s)
shall be fully adjustable without tools and should be equipped with MR16
halogen lamp(s) of
V
W.
The remote fixtures shall be certified to CSA 22.2 No.141-15.
The remote unit shall be the Lumacell® model:
.
NEMA-4X
REPLACEMENT LAMPS: MQMP
VOLTAGE/
WATTAGE
MODEL
LAMP TYPE
580.0074-L
MR16 flood
6V-6W
580.0079-L
MR16 flood
6V-10W
580.0080-L
MR16 flood
12V-12W
580.0070-L
MR16 flood
24V-12W
580.0097-L
MR16 LED
6V-4W
580.0093-L
MR16 LED
12V-4W
580.0104-L
MR16 LED
12V-5W
580.0106-L
MR16 LED
12V-6W
580.0098-L
MR16 LED
24V-4W
See the complete list p. 152-154.
REPLACEMENT LAMPS: MQM
8
www.lumacell.com
MODEL
LAMP TYPE
VOLTAGE/
WATTAGE
580.0068-L
MR16 IR flood
12V-20W
580.0077-L
MR16 flood
24V-20W
580.0100-L
MR16 LED
24V-6W
580.0113-L
MR16 LED
120V-4W
• Clear polycarbonate UV and impact resistant lens
• Choice of single or double lamp models
• Available in 6, 12 and 24V models MR16 or LED
• Easy lamp Type:
replacement
Type:
• Project/Location:
Comes standard with tamper-proof screws and bit
Project/Location:
•Project/Location:
NSF Certified for food processing plants
Contractor:
• NEMA-4X
Certified*
Contractor:
•Contractor:
Suitable for indoor/outdoor installation
Prepared By:
• CSAPrepared
CertifiedBy:
to C22.2 No. 141-15
configurations according to the design. These fixtures shall be fully gasketed
with a UV resistant and fire retardant polycarbonate back plate with a clear
heavy-duty UV resistant polycarbonate light cover. The unit shall be equipped
with two emergency heads with tool-less adjustable swivels (lamps of 12W or
less). Units shall be NEMA-4X and NSF certified and specifically designed for
high abuse areas, wet and cold weather locations, food processing plants as
well in applications requiring a resistance to corrosive agents. The standard
unit will come with stainless steel tamper-proof screws and bit.
The remote fixture shall be certified to CSA C22.2 No. 141-15. The head(s)
shall be fully adjustable without tools and should be equipped with MR16
halogen lamp(s) of
V
W.
The remote fixtures shall be certified to CSA 22.2 No.141-15.
Remote Fixture
The remote unit shall be the Lumacell® model:
.
MQM-NX
Survive-All™ EF39
Series
& EF39PNEMA-4X
Series
Certified
Date:
See warranty
details at: www.tnb.ca/en/brands/lumacell
Date:
*Date:
For MQMP, units are NEMA-4X Certified when installed using a circular NEMA-4X rated junction box (sold
No.: under P/N CE365D-CAR or CE365DW-CAR and with plugs P/N P7701W-CAR).
seperatlyModel
by Thomas&Betts
Model
No.:
Prepared by:
NEMA-4X
NEMA-4X Certified
Remote Fixture
REPLACEMENT LAMPS: MQMP
DIMENSIONS
DIMENSIONS
Dimensions are
approximate
andand
subject
to change.
Dimensions
are
approximate
subject
to change.
73/8” [18.7 cm]
33/4” [9.5 cm]
47/8” [12.3 cm]
73/87-3/8”
” [18.7[18.7
cm] cm]
p. 65
p. 67
47/8”[12.3
[12.3cm]
cm]
4-7/8”
- 3LER3000
Combination Unit
LAMP TYPE
MR16 flood
VOLTAGE/WATTAGE
6V-6W
580.0079-L
MR16 flood
6V-10W
580.0080-L
MR16 flood
12V-12W
580.0070-L
MR16 flood
24V-12W
580.0093-L
MR16 LED
12V-4W
3-3/4”
[9.5 cm]
3/4
580.0097-L 3 ” [9.5 cm] MR16 LED
IN THE SAME FAMILY: NEMA 4X
- LER300 Series
Exit Sign
MODEL
580.0074-L
6V-4W
580.0104-L
MR16 LED
12V-5W
580.0106-L
MR16 LED
12V-6W
580.0098-L
MR16 LED
24V-4W
See the complete list p. 152-154.
REPLACEMENT LAMPS: MQM
MODEL
LAMP TYPE
VOLTAGE/WATTAGE
- RG-NX NEMA 4X Series
Battery Unit
580.0068-L
MR16 IR flood
12V-20W
p. 118-119
580.0077-L
MR16 flood
24V-20W
ORDERING INFORMATION: MQMP
SERIES
580.0100-L
MR16 LED
24V-6W
580.0113-L
MR16 LED
120V-4W
LAMP TYPE/VOLTAGE/WATTAGE
COLOUR
OPTIONS
ORDERING INFORMATION: EF39P
ORDERING INFORMATION: MQMP
MQMP1NX= polycarbonate, one lamp
MQMP2NX= polycarbonate, two
lamps
SERIES
SERIES
LD1= MR16 LED, 6V-4W
6V6W= MR16 halogen, 6V-6W
Blank= factory white
-SM= surface mount*
LD7= MR16 LED, 12V-4W
6V10W= MR16 halogen, 6V-10W
BK= black
LD9= MR16 LED, 12V-5W
12V12W= MR16 halogen, 12V-12W
SG= grey
NUMBERLD10=
OF LAMPS
LAMP TYPE24V12W= MR16
COLOUR
LAMP TYPE/VOLTAGE/WATTAGE
OPTIONS
MR16
LED, 12V-6W
halogen, 24V-12W
* surface plastic
junction box included
LAMP
TYPE/VOLTAGE/WATTAGE
COLOUR
OPTIONS
EF39P= polycarbonate Blank= one lamp
M= MR16
Blank= factory
-LA= MR16 LED, 6V-4W
EXAMPLE:
MQMP1NX=
pMQMP1NX6V6WBK
olycarbonate,
lamplamps
LD1= MR16 LED, 6V-4W
6V6W= MR16white
halogen, 6V-6W -LG= MR16
Blank=
factory
white
NEMA
4X back one
D= two
LED,
12V-4W
MQMP2NX=
p
olycarbonate,
two
LD7=
MR16
LED,
12V-4W
6V10W=
M
R16
halogen,
6V-10W
BK= LED,
black 12V-5W
plate
-B= black
-LI= MR16
lamps
LD9= MR16 LED, 12V-5W
12V12W=
M
R16 halogen, 12V-12W
SG= grey
-G= grey
-LJ= MR16
LED, 12V-6W
LD10= MR16 LED, 12V-6W
24V12W= MR16 halogen, 24V-12W
-LL= MR16 LED, 24V-4W
SERIES LD13= MR16 LED, 24V-4W LAMP TYPE/VOLTAGE/WATTAGE
-6V6W= MR16 halogen, 6V-6W
-SM= surface mount*
-SM= surface mount*
ORDERING INFORMATION: MQM
-6V10W= MR16 halogen, 6V-10W
12V20WH= MR16-IR, 12V-20W, high output
Blank= factory white
-12V12W= MR16 halogen, 12V-12W
24V20W= MR16 halogen, 24V-20W
BK= black
-24V12W= MR16 halogen, 24V -12W
LD14= MR16 LED, 24V-6W
SG= grey
LD26= MR16 LED, 120V-4W
Other colours available.
MQM1NX= Die-Cast, one lamp
MQM2NX= Die-Cast, two lamps
EXAMPLE: MQM2NX12V20W
* Surface plastic junction box included
* surface plastic junction box
included
EXAMPLE: MQMP1NX6V6WBK
EXAMPLE: EF39PDM-B-6V6W
ORDERING INFORMATION: MQM
ORDERING INFORMATION:
EF39 LAMP TYPE/VOLTAGE/WATTAGE
SERIES
MQM1NX= SERIES
D
ie-Cast, one lamp
MQM2NX= D
ie-Cast, two lamps
EF39= die-cast NEMA 4X
back plate
COLOUR
NUMBER OF LAMPS
LAMP12V-20W,
TYPE high output
12V20WH= MR16-IR,
Blank= one lamp
D= two lamps
24V20W= MR16 halogen, 24V-20W
M= MR16
LD14= MR16 LED, 24V-6W
LD26= MR16 LED, 120V-4W
www.lumacell.com
149
COLOUR
COLOUR Blank= factory
LAMP
whiteTYPE/VOLTAGE/WATTAGE
BK= black
Blank= factory white
-12V20W= MR16-IR, 12V-20W, high output
SG= silver/ grey
-B= Black
-24V20W= MR16 halogen, 24V-20W
-G= grey
-LM= MR16 LED, 24V-6W
EXAMPLE: MQM2NX12V20W
EXAMPLE: EF39DM-12V20W
149
www.lumacell.com
9
Photometrics
The Lumacell® NEMA-4X Series of emergency lighting sets an impressive new standard for center-to-center
path of egress illumination. Battery units and fixtures illuminate an egress path 89-feet long and 6-feet-wide.
Photometric data based on a 7-foot mounting height, minimum 80-50-20 reflectance values and 12V-6W MR16 LED lamps.
3D image showing installation of two RG-NX Series battery units and a LNC
combination unit in an industrial application under normal lighting conditions.
3D image lighting rendering showing installation of two RG-NX Series battery
units and a LNC combination unit in an industrial application under emergency
lighting conditions.
1FC a
verag
e
7.5’
70’
6’
3D light level coloured scale image showing egress illumination pattern generated by
two RG-NX battery units and a LNC combination unit.
ISO curve on a point-by-point of two RG-NX Series battery units.
NOTE: Photometric results shown are based on a simulation using the AGI32 software with a 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum-minimum ratio.
Lumacell® assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not a guarantee of any code compliances.
10
www.lumacell.com
www.lumacell.com
All information and specifications contained in this flyer
are subject to change due to engineer design, errors and
omissions.
Illustrations and diagrams within this flyer may vary from
actual products.
© 2016. Thomas&Betts Limited. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement