CLI Maintenance - AskF5

CLI Maintenance - AskF5
ARX CLI Maintenance Guide
810-0045-00
Publication Date
This manual was published on September 24, 2012.
Legal Notices
Copyright
Copyright 2006-9/24/12, F5 Networks, Inc. All rights reserved.
F5 Networks, Inc. (F5) believes the information it furnishes to be accurate and reliable. However, F5
assumes no responsibility for the use of this information, nor any infringement of patents or other rights of
third parties which may result from its use. No license is granted by implication or otherwise under any
patent, copyright, or other intellectual property right of F5 except as specifically described by applicable
user licenses. F5 reserves the right to change specifications at any time without notice.
Trademarks
3DNS, Access Policy Manager, Acopia, Acopia Networks, Advanced Client Authentication, Advanced
Routing, APM, Application Security Manager, ARX, AskF5, ASM, BIG-IP, Cloud Extender,
CloudFucious, Clustered Multiprocessing, CMP, COHESION, Data Manager, DevCentral, DevCentral
[DESIGN], DSI, DNS Express, DSC, Edge Client, Edge Gateway, Edge Portal, ELEVATE, EM,
Enterprise Manager, ENGAGE, F5, F5 [DESIGN], F5 Management Pack, F5 Networks, F5 World, Fast
Application Proxy, Fast Cache, FirePass, Global Traffic Manager, GTM, GUARDIAN, IBR, Intelligent
Browser Referencing, Intelligent Compression, IPv6 Gateway, iApps, iControl, iHealth, iQuery, iRules,
iRules OnDemand, iSession, IT agility. Your way., L7 Rate Shaping, LC, Link Controller, Local Traffic
Manager, LTM, Message Security Module, MSM, Netcelera, OneConnect, OpenBloX, OpenBloX
[DESIGN], Packet Velocity, Protocol Security Module, PSM, Real Traffic Policy Builder, Rosetta
Diameter Gateway, ScaleN, Signaling Delivery Controller, SDC, SSL Acceleration, StrongBox,
SuperVIP, SYN Check, TCP Express, TDR, TMOS, Traffic Management Operating System,
TrafficShield, Traffix Diameter Load Balancer, Traffix Systems, Traffix Systems (DESIGN), Transparent
Data Reduction, UNITY, VAULT, VIPRION, vCMP, virtual Clustered Multiprocessing, WA, WAN
Optimization Manager, WANJet, WebAccelerator, WOM, and ZoneRunner, are trademarks or service
marks of F5 Networks, Inc., in the U.S. and other countries, and may not be used without F5's express
written consent.
All other product and company names herein may be trademarks of their respective owners.
Patents
This product may be protected by U.S. Patents 7,877,511; 7,958,347. This list is believed to be current as
of September 24, 2012.
Export Regulation Notice
This product may include cryptographic software. Under the Export Administration Act, the United States
government may consider it a criminal offense to export this product from the United States.
RF Interference Warning
This is a Class A product. In a domestic environment this product may cause radio interference, in which
case the user may be required to take adequate measures.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This unit generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a residential area
is likely to cause harmful interference, in which case the user, at his own expense, will be required to take
whatever measures may be required to correct the interference.
CLI Maintenance Guide
iii
Any modifications to this device, unless expressly approved by the manufacturer, can void the user's
authority to operate this equipment under part 15 of the FCC rules.
Canadian Regulatory Compliance
This Class A digital apparatus complies with Canadian ICES-003.
Standards Compliance
This product conforms to the IEC, European Union, ANSI/UL and Canadian CSA standards applicable to
Information Technology products at the time of manufacture.
Acknowledgments
This product includes software from several third-party vendors. Each vendor is listed below with
applicable copyright.
Copyright (c) 1990, 1993, 1994, 1995 The Regents of the University of California. All rights reserved.
Copyright 2000 by the Massachusetts Institute of Technology. All Rights Reserved.
Export of this software from the United States of America may require a specific license from the United
States Government. It is the responsibility of any person or organization contemplating export to obtain
such a license before exporting.
Copyright 1993 by OpenVision Technologies, Inc.
Copyright (C) 1998 by the FundsXpress, INC.
All rights reserved.
Export of this software from the United States of America may require a specific license from the United
States Government. It is the responsibility of any person or organization contemplating export to obtain
such a license before exporting.
Copyright (c) 1995-2001 International Business Machines Corporation and others
All rights reserved.
Copyright (c) 1990-2003 Sleepycat Software. All rights reserved.
Copyright (c) 1995, 1996 The President and Fellows of Harvard University. All rights reserved.
Copyright (c) 1998-2004 The OpenSSL Project. All rights reserved.
Unless otherwise noted, the companies, organizations, products, domain names, email addresses, logos,
people, places, and events depicted in examples herein are fictitious. No association with any real
company, organization, product, domain name, email address, logo, person, place, or event is intended or
should be inferred.
Revision History
September 2006 - Rev A
October 2006 - Rev B, updates for Software Release 2.4.2
March 2007 - Rev C, updates for Software Release 2.5.0
May 2007 - Rev D, updates for Software Release 2.5.1
November 2007 - Rev E, new Security-Table Appendix for Software Release 2.7.0
December 2007 - Rev F, updates for Software Release 3.0.0
March 2008 - Rev G, updates for Software Release 3.1.0; convert to F5 format
June 2008 - Rev H, updates for Software Release 4.0.0
October 2008 - Rev J, re-brand the OS
June 2009 - Rev K, updates for Software Release 5.00.000
July 2009 - Rev L, minor updates for Software Release 5.00.001
July 2009 - Rev M, re-orient policy discussion toward latest best-practices, for Software Release 5.00.005
November 2009 - Rev N, updates for Software Release 5.01.000
March 2010 - Rev P, updates for Software Release 5.01.005
August 2010 - Rev Q, updates for Software Release 5.01.007
November 2010 - Rev R, updates for Software Release 5.02.000
June 2011 - Rev S, updates for Software Release 6.00.000
iv
September 2011 - Rev T, updates for Software Release 6.01.000
January 2012 - Rev U, minor updates for 6.01.001.14111 hot fix
July 2012 - Rev V, updates for Software Release 6.02.000
October 2012 - Rev W, updates for Software Release 6.03.000
CLI Maintenance Guide
v
vi
Table of Contents
Table of Contents
1
Introduction
Overview ..........................................................................................................................................1-3
The ARX ...........................................................................................................................................1-3
Back-end Storage and Servers ............................................................................................1-3
Front-end Services .................................................................................................................1-4
Policy .........................................................................................................................................1-4
Resilient Overlay Network (RON) ...................................................................................1-4
Audience for this Manual ..............................................................................................................1-4
Using this Manual ............................................................................................................................1-5
Document Conventions ................................................................................................................1-5
CLI Overview ...................................................................................................................................1-7
Exec Mode ...............................................................................................................................1-7
Priv-exec Mode ......................................................................................................................1-7
Exiting a Mode ........................................................................................................................1-8
Prompts ....................................................................................................................................1-8
The no Convention ...............................................................................................................1-8
The enable/no enable Convention .....................................................................................1-8
Getting Started ................................................................................................................................1-9
Entering Cfg or Gbl Mode ...................................................................................................1-9
Sample Network........................................................................................................................... 1-11
Contacting Customer Service ................................................................................................... 1-12
2
Configuring Volume Snapshots
Overview ..........................................................................................................................................2-3
Before You Begin ............................................................................................................................2-4
NetApp Configuration ..........................................................................................................2-4
WinRM on Windows ............................................................................................................2-4
EMC Celerra Best Practices ................................................................................................2-5
EMC Data Domain Best Practices .....................................................................................2-5
Creating a Proxy User for Accessing the Filer’s CLI .....................................................2-5
Preparing an External-Filer Configuration .......................................................................2-6
Creating a Snapshot Rule ..............................................................................................................2-6
Changing the Name of the Snapshot Directory (optional) ..........................................2-7
Changing the Number of Retained Snapshots (optional) .............................................2-8
Excluding a Share (optional) ................................................................................................2-8
Sparse Snapshots ....................................................................................................................2-9
Applying a Schedule (optional) ...........................................................................................2-9
Configuring a Progress Report (optional) ..................................................................... 2-11
Enabling the Snapshot Rule ............................................................................................... 2-14
Removing all Snapshots Behind a Rule ........................................................................... 2-14
Removing a Snapshot Rule ................................................................................................ 2-18
Incorporating a Pre-Existing Snapshot .................................................................................... 2-18
Using a Different Prefix for the Error Report ............................................................. 2-19
Generating a Report When the Operation Succeeds ................................................ 2-19
Clearing the Snapshot from the ARX Configuration ................................................. 2-20
Supporting VSS for Pre-XP Clients .......................................................................................... 2-22
Restricting VSS Support to XP and Later Clients ....................................................... 2-22
Restricting Access to Snapshots ............................................................................................... 2-23
Client-Based Access Control: WMA Groups .............................................................. 2-23
Shutting Down Support for the VSS Interface ............................................................. 2-25
Displaying the Root ~snapshot Directory .................................................................... 2-25
Setting the “Hidden” Flag for the Snapshot Directory .............................................. 2-27
CLI Maintenance Guide
ix
Table of Contents
Changing the Name of the ~snapshot Directory ........................................................ 2-28
Enabling Snapshot Consistency ................................................................................................. 2-29
Fencing Timeouts ................................................................................................................ 2-29
Disabling VIP Fencing (and Consistency) ....................................................................... 2-29
Creating a Manual Snapshot ...................................................................................................... 2-31
Verifying a Rule’s Snapshots ...................................................................................................... 2-32
Verifying a Single Snapshot ............................................................................................... 2-34
Running Snapshot Operations from a Remote Host ........................................................... 2-34
Showing All ARX Snapshots ...................................................................................................... 2-37
Focusing on a Single Namespace, Volume, or Rule .................................................... 2-38
Preparing for Snapshot Reconstitution ................................................................................... 2-41
Maintaining the Repository for Snapshot Reports ...................................................... 2-41
Reconstituting ARX Snapshots ........................................................................................ 2-42
Replica Snapshot Shares ............................................................................................................. 2-45
Replica-Snap Share Configuration ................................................................................... 2-45
Replica-Snap Rule Configuration ..................................................................................... 2-45
Displaying Replica Snapshot Information ...................................................................... 2-47
Behavioral Considerations For Replica Snapshot Shares .......................................... 2-47
3
Tracking Files on Your Back-End Storage
Overview ..........................................................................................................................................3-3
Before You Begin ............................................................................................................................3-3
NetApp Configuration ..........................................................................................................3-3
EMC Celerra Best Practices ................................................................................................3-4
Creating a Proxy User for Managing the Filer ................................................................3-4
Preparing an External-Filer Configuration .......................................................................3-4
Creating a File-History Archive ...................................................................................................3-6
Choosing a Location for the Archive Data ......................................................................3-6
Setting a Description for the Archive ............................................................................ 3-10
Listing All File-History Archives ...................................................................................... 3-10
Removing an Archive ......................................................................................................... 3-11
Storing File History in the Archive .......................................................................................... 3-12
Choosing a File-History Archive ..................................................................................... 3-12
Selecting the Contents of the Snapshot ........................................................................ 3-13
Applying a Schedule (optional) ........................................................................................ 3-14
Configuring a Progress Report (optional) ..................................................................... 3-15
Enabling the Snapshot Rule ............................................................................................... 3-15
Client Access During an Archive Operation: the VIP Fence .................................... 3-16
Canceling an Archive Operation ..................................................................................... 3-16
Removing all Snapshots Behind a Rule ........................................................................... 3-17
Removing a Snapshot Rule ................................................................................................ 3-17
Showing Historical Configurations ........................................................................................... 3-19
For a Particular Day ........................................................................................................... 3-19
For a Range of Dates ......................................................................................................... 3-21
Showing File History ................................................................................................................... 3-25
For a Particular Day ........................................................................................................... 3-25
With Input/Output Options ............................................................................................. 3-27
For a Range of Dates ......................................................................................................... 3-28
Finding a File’s Current Location ............................................................................................. 3-32
Showing the NFS Filehandles ........................................................................................... 3-33
Finding the File with a Global-Server Name ................................................................. 3-33
Finding the File with a WINS Name ............................................................................... 3-34
Finding the File from a Namespace Perspective .......................................................... 3-34
Maintaining a File-History Archive: Listing Records ............................................................ 3-36
x
Table of Contents
For a Particular Day ........................................................................................................... 3-36
For a Range of Dates ......................................................................................................... 3-37
Clearing Records from a File-History Archive ............................................................ 3-39
4
Restoring a Volume’s Files
Overview ..........................................................................................................................................4-3
Moving the Backup File(s) to the Staging Area ........................................................................4-4
Manually Restoring File(s) .............................................................................................................4-6
Automatically Restoring File(s) ....................................................................................................4-7
Adding an External Filer for the Staging Area (optional) .............................................4-7
Restoring Client Data ...........................................................................................................4-8
5
Backing Up the Running Configuration
Overview ..........................................................................................................................................5-3
Setting a Default FTP or SCP User .............................................................................................5-3
Saving the Local Running Config ..................................................................................................5-5
Saving the Config Off to an FTP Server ............................................................................5-5
Saving the Config Off to an SCP Server ...........................................................................5-6
Placing the Config into an ARX Volume ..........................................................................5-7
Sending the Config to an E-Mail Recipient .......................................................................5-7
Showing the Local Config ....................................................................................................5-8
Saving the Global Config ...............................................................................................................5-9
Saving the Config Off to an FTP Server ............................................................................5-9
Saving the Config Off to an SCP Server ........................................................................ 5-10
Placing the Config into an ARX Volume ....................................................................... 5-10
Sending the Config to an E-Mail Recipient .................................................................... 5-11
Showing the Global Config ............................................................................................... 5-12
Saving Both Configs ..................................................................................................................... 5-18
Saving the Config Off to an FTP Server ......................................................................... 5-18
Saving the Config Off to an SCP Server ........................................................................ 5-19
Placing the Config into an ARX Volume ....................................................................... 5-19
Sending the Config to an E-Mail Recipient .................................................................... 5-20
Prepared for Disaster Recovery ............................................................................................... 5-21
Restoring the Configuration ...................................................................................................... 5-21
Erasing the Current Configuration ................................................................................. 5-21
Restoring the Local and Global Configs ........................................................................ 5-22
Restoring Configs to a Redundant Pair ......................................................................... 5-23
6
Upgrading Software
Overview ..........................................................................................................................................6-3
Downgrades ............................................................................................................................6-3
Before You Begin ............................................................................................................................6-4
Performance Considerations For ARX-1500 and ARX-2500 .....................................6-4
Coordinating Upgrades Between Shadow-Volume Sites ..............................................6-4
Saving the Configuration ...............................................................................................................6-5
Other Important Configuration Parameters ...................................................................6-5
Checking the Health of the Switch .............................................................................................6-6
Checking the Log Files for Errors ......................................................................................6-6
Changing the Software Release ...................................................................................................6-7
Clearing Space for a New Release File .............................................................................6-7
CLI Maintenance Guide
xi
Table of Contents
Obtaining a New Release File .............................................................................................6-8
Copying a Release File to the Switch ................................................................................6-9
Arming the Switch with the Release File ....................................................................... 6-13
Rebooting the Switch ......................................................................................................... 6-14
Activating the Software License (If Necessary) ........................................................... 6-14
Rebuilding the Configuration (Downgrade Only) ....................................................... 6-15
Verifying the Installation .................................................................................................... 6-16
Checking for New Firmware .................................................................................................... 6-17
Sanity Check .................................................................................................................................. 6-18
Upgrading a Redundant Pair ...................................................................................................... 6-19
Saving the Configuration ................................................................................................... 6-19
Verifying the Active Switch’s Ability to Stand Alone .................................................. 6-19
Upgrading the Backup Switch .......................................................................................... 6-21
Checking for New Firmware ........................................................................................... 6-23
Sanity Check ........................................................................................................................ 6-23
Checking the Health of the Active Switch .................................................................... 6-24
Failing Over to the Upgraded Switch ............................................................................. 6-24
Testing the New Release .................................................................................................. 6-24
Success Path ......................................................................................................................... 6-25
Failure Path ........................................................................................................................... 6-25
Downgrading a Redundant Pair ................................................................................................ 6-27
Saving the Configuration ................................................................................................... 6-27
Downgrading the Backup Switch .................................................................................... 6-28
Sanity Check ........................................................................................................................ 6-31
Downgrading the Active Switch ...................................................................................... 6-31
Sanity Check ........................................................................................................................ 6-35
Restoring Redundancy ....................................................................................................... 6-35
7
Metadata Utilities: nsck and sync
Overview ..........................................................................................................................................7-3
Showing the Progress of nsck and sync Jobs ............................................................................7-4
Showing the nsck/sync Jobs for One Namespace ..........................................................7-5
Showing One nsck/sync Job .................................................................................................7-5
Showing all nsck/sync Jobs ...................................................................................................7-5
Showing all nsck/sync Reports ............................................................................................7-6
Showing Metadata ...........................................................................................................................7-8
Focusing on One Share ..................................................................................................... 7-10
Sending the Output to a Different File .......................................................................... 7-10
Canceling the Report ......................................................................................................... 7-11
Showing Directory Structure .................................................................................................... 7-12
Example ................................................................................................................................. 7-12
Cancelling the Report ........................................................................................................ 7-14
Warning Signs for Metadata Inconsistencies ......................................................................... 7-15
Finding Metadata Inconsistencies ............................................................................................. 7-16
Focusing on Multi-Protocol Issues .................................................................................. 7-18
Canceling the Report ......................................................................................................... 7-21
Synchronizing Metadata with Actual Files .............................................................................. 7-22
Synchronizing with Actual Directories .......................................................................... 7-24
Synchronizing Metadata in a Single Share ...................................................................... 7-26
Synchronization Occurs in Share-Priority Order ....................................................... 7-26
Showing the Progress of All Sync Operations ............................................................. 7-27
Canceling a Sync Operation ............................................................................................. 7-29
Adding and Synchronizing Filer Subshares (CIFS) ................................................................ 7-30
Rebuilding a Namespace ............................................................................................................. 7-32
xii
Table of Contents
Directory Mastership After a Rebuild ............................................................................ 7-33
Rebuilding a Volume ........................................................................................................... 7-33
Forcing the Rebuild ............................................................................................................ 7-34
De-Staging a Namespace’s Managed Volumes ...................................................................... 7-35
De-Staging the Volumes in a Volume Group ............................................................... 7-36
De-Staging a Single Volume .............................................................................................. 7-38
Forcing the De-Stage ......................................................................................................... 7-38
Re-Enabling the Shares ...................................................................................................... 7-39
Migrating Metadata to a New Back-End Share ...................................................................... 7-40
Canceling a Metadata Migration ...................................................................................... 7-41
Clearing All nsck Jobs ................................................................................................................. 7-42
Clearing One nsck Job ....................................................................................................... 7-42
Truncating a Report ........................................................................................................... 7-42
8
Troubleshooting Tools
Overview ..........................................................................................................................................8-3
Showing All Active Alarms ............................................................................................................8-4
Clearing SNMP Traps ...........................................................................................................8-4
Showing Time Skews Between the ARX and Other Servers ...............................................8-5
Accessing the Syslog .......................................................................................................................8-7
Tailing the Syslog ....................................................................................................................8-8
Log Components ...................................................................................................................8-9
Syslog Syntax ........................................................................................................................ 8-16
Reading IDs for Namespaces, Volumes, and Shares ................................................... 8-17
Paging Through the Syslog (show logs) ......................................................................... 8-18
Searching Through the Syslog .......................................................................................... 8-19
Showing the Documentation for a Syslog Message .................................................... 8-21
Copying the Syslog File to an FTP Server ..................................................................... 8-22
Adjusting Logging Levels .................................................................................................... 8-24
Sending Logs to an External Server ......................................................................................... 8-27
Removing a Logging Destination ..................................................................................... 8-27
Sending Log Messages from a VLAN Interface (optional) ......................................... 8-27
Showing all Logging Destinations .................................................................................... 8-28
Listing Current System Tasks ................................................................................................... 8-29
Collecting Diagnostic Information ........................................................................................... 8-30
Sending the Information Securely, through SCP ......................................................... 8-30
Placing the Diagnostics File into an ARX Volume ....................................................... 8-31
Sending the Information in an E-Mail Message ............................................................. 8-32
Collecting the Information Locally .................................................................................. 8-33
Running the Collection Asynchronously ....................................................................... 8-34
Collecting Partial Information .......................................................................................... 8-34
Collecting Logs within a Time Frame ............................................................................. 8-35
Setting Up Remote Monitoring By F5 Support ..................................................................... 8-37
Setting the Collection Schedule ....................................................................................... 8-37
Adding Additional Show Commands to the Collection ............................................ 8-38
Adding Additional E-mail Recipients ............................................................................... 8-39
Running Show Commands from a Remote Host ................................................................. 8-42
Using Quotes within the Show Command ................................................................... 8-42
Notification Rules ........................................................................................................................ 8-44
Statistics Monitoring .................................................................................................................... 8-45
Statistics Monitor Command Mode ............................................................................... 8-46
Statistics Monitor Log Files ............................................................................................... 8-48
CLI Maintenance Guide
xiii
Table of Contents
9
Troubleshooting Network Connections
Pinging an IP Address .....................................................................................................................9-3
Limiting the Ping Count ........................................................................................................9-3
Pinging From an Alternate Source IP ................................................................................9-4
Using Traceroute ............................................................................................................................9-6
Testing Throughput with TTCP ..................................................................................................9-7
Cancelling a TTCP Transmission .......................................................................................9-7
Testing a RON Tunnel .........................................................................................................9-7
Tracing NSM Processes in the “fastpath” Log .........................................................................9-9
NSM-Log Components .........................................................................................................9-9
Adjusting NSM Logging Levels ......................................................................................... 9-11
Disabling Logs from an NSM Processor ........................................................................ 9-13
Accessing the fastpath Log ................................................................................................ 9-14
Capturing IP Traffic in a File ...................................................................................................... 9-16
Changing the Size and Number of Capture Files ........................................................ 9-17
Focusing on CIFS Traffic .................................................................................................... 9-17
Stopping the Capture ......................................................................................................... 9-18
Capturing All Proxy-IP Traffic .......................................................................................... 9-18
Listing All Capture Files ..................................................................................................... 9-19
Merging the Files from a Multi-File Capture ................................................................. 9-23
Copying the Capture File(s) to a Remote Site ............................................................. 9-24
Configuring Port Mirroring ........................................................................................................ 9-25
Using an Alternative Destination Interface ................................................................... 9-25
Showing Active Port-Mirroring Sessions ....................................................................... 9-26
Shutting Down Port Mirroring ........................................................................................ 9-26
Showing Filer-Connection Statistics ........................................................................................ 9-28
Focusing On a Particular Filer .......................................................................................... 9-28
Clearing the Filer-Connection Statistics ........................................................................ 9-29
Dropping All Connections to a Filer .............................................................................. 9-30
10
Troubleshooting Managed Volumes
Overview ....................................................................................................................................... 10-3
Showing Share Statistics ............................................................................................................. 10-4
Showing Share Statistics from One Namespace .......................................................... 10-7
Showing Metadata Statistics ..................................................................................................... 10-10
Draining One or More Shares ................................................................................................ 10-12
Identifying the Source Share(s) ...................................................................................... 10-12
Choosing the Target Storage ......................................................................................... 10-13
Setting Other Placement-Rule Options ....................................................................... 10-13
Retaining Copies of Files on the Share (optional) ..................................................... 10-14
Making the Rule Tentative .............................................................................................. 10-15
Enabling the Drain Rule ................................................................................................... 10-15
Verifying That All Files Are Removed .......................................................................... 10-16
Removing the Drain Rule ................................................................................................ 10-17
Removing an Imported Share .................................................................................................. 10-18
Removing the Empty Directory Tree .......................................................................... 10-19
Extra Processing in a Multi-Protocol Volume ............................................................ 10-19
Finding Reports About the Share Removal ................................................................ 10-20
Removing the Share Asynchronously ........................................................................... 10-23
Removing Shares Without File Migration ................................................................... 10-24
Canceling a Share Removal ............................................................................................. 10-25
Removing An Offline Share ..................................................................................................... 10-26
xiv
Table of Contents
Correcting Share-Import Errors ............................................................................................ 10-27
Restarting the Import ...................................................................................................... 10-45
Removing the Share from the Volume ........................................................................ 10-45
Reimporting the Entire Volume ..................................................................................... 10-48
Removing a Full Namespace Service ..................................................................................... 10-49
Removing All Policy Objects from a Namespace ...................................................... 10-50
Managing Namespace Collisions ............................................................................................. 10-52
Finding the Renamed Files .............................................................................................. 10-52
Managing Collisions With CIFS 8.3 Names .......................................................................... 10-55
The 8.3-FGN Pattern ....................................................................................................... 10-55
8.3 FGNs Do Not Exist in an ARX Volume ............................................................... 10-56
Best Practice: Avoid Primary Names That Match The 8.3 Pattern ....................... 10-56
8.3 FGN Collision Avoidance ........................................................................................ 10-56
Identifying 8.3 FGN Collisions ....................................................................................... 10-57
Fixing File/Directory Names with Trailing Periods ............................................................ 10-59
Illegal Client Operations ................................................................................................. 10-59
Finding Imported Files with Illegal Trailing Characters ............................................ 10-60
Finding Shares That Convert Trailing-Period Names to FGNs ............................. 10-61
Disallowed Migrations and Replications ...................................................................... 10-63
Finding NFS-Only Entries in a Multi-Protocol Volume ..................................................... 10-64
Best Practice: Avoid NFS-Only Entries Where Practical ........................................ 10-64
Identifying Problematic Entries ...................................................................................... 10-65
Correcting NFS-Only Entries ........................................................................................ 10-70
Running Periodic Checks for NFS-Only Entries ........................................................ 10-71
Migrations in a Multi-Protocol Namespace .......................................................................... 10-72
File-Attribute Migrations ................................................................................................. 10-72
Showing Policy History for a Volume ................................................................................... 10-76
Showing Detailed Status for a Particular Rule ........................................................... 10-76
Showing Any or All Pending Migrations ...................................................................... 10-77
Addressing Inconsistent Directory Attributes .................................................................... 10-80
Metadata Inconsistencies ................................................................................................. 10-80
Attribute Inconsistency Use Cases ............................................................................... 10-80
Finding and Showing Inconsistent Attributes ............................................................. 10-81
Resolving Directory Attribute Inconsistency ............................................................. 10-82
Per Operation Restriction Summary ............................................................................ 10-82
11
Troubleshooting CIFS Services
Overview ....................................................................................................................................... 11-3
Showing Client-Connection Statistics ..................................................................................... 11-3
Showing Statistics from One NSM Processor ............................................................. 11-8
Showing Client Sessions ........................................................................................................... 11-10
Showing Client Sessions at One NSM Processor ..................................................... 11-10
Showing CIFS Work Queue Statistics .................................................................................. 11-12
Showing CIFS Fastpath Statistics ............................................................................................ 11-13
Dropping a CIFS Client ............................................................................................................ 11-14
Listing Open Files in a CIFS Service ....................................................................................... 11-15
Focusing on One NSM Processor ................................................................................. 11-16
Closing an Open File ................................................................................................................. 11-18
Listing Kerberos Tickets Granted to Clients ...................................................................... 11-20
Listing Tickets Granted to a Particular Principal ....................................................... 11-20
Leaving and Rejoining an AD Domain ................................................................................... 11-22
Saving the CIFS-Service Configuration ......................................................................... 11-22
Dropping Terminal-Confirmation Prompts ................................................................ 11-23
Clearing Dynamic-DNS Hostnames (If Necessary) .................................................. 11-23
CLI Maintenance Guide
xv
Table of Contents
Removing the CIFS Service ............................................................................................. 11-24
Restoring the CIFS-Service Configuration .................................................................. 11-24
Rejoining the AD Domain and Enabling the Service ................................................. 11-24
Restoring Dynamic-DNS Hostnames (If Necessary) ................................................ 11-25
Turning Confirmation Prompts Back On .................................................................... 11-25
Changing the Proxy User Password ...................................................................................... 11-26
12
GUI Maintenance
Overview ....................................................................................................................................... 12-3
Removing the SSL Key ................................................................................................................ 12-3
Restarting the GUI ....................................................................................................................... 12-5
13
Powering Down the ARX
Overview ....................................................................................................................................... 13-3
Saving Configuration Parameters ............................................................................................. 13-3
Checking the NVRAM Battery ................................................................................................. 13-5
Turning Off the Power ............................................................................................................... 13-6
Manually Turning Off the Power ..................................................................................... 13-6
Limited Down Time .................................................................................................................... 13-6
Restoring Power .......................................................................................................................... 13-7
Verifying Successful Power-Up ........................................................................................ 13-7
14
ARX Disaster Recovery
Overview ....................................................................................................................................... 14-3
Before You Begin ......................................................................................................................... 14-6
Preparing Back-End Filers ................................................................................................. 14-6
Verifying That Master Keys Are Identical ..................................................................... 14-6
Removing Existing Global Configuration From the Backup ARXes ....................... 14-7
Configuring a RON Mesh ................................................................................................. 14-7
Disaster Recovery Configuration ............................................................................................. 14-9
Disaster Recovery Configuration Summary ................................................................. 14-9
Defining Cluster Names .................................................................................................... 14-9
Adding the Backup Cluster’s Filers to the Active Cluster’s Configuration ......... 14-10
Assigning SAM-Reference Filers .................................................................................... 14-11
Assigning Metadata Shares .............................................................................................. 14-11
Assigning Volume Shares ................................................................................................. 14-12
Assigning VIPs For Each Cluster .................................................................................... 14-13
Adding the Backup Cluster’s Filers to the CIFS Service’s Delegate-To List ....... 14-13
Replicating the Global Config to the Backup Cluster .............................................. 14-13
Manual Failover Tasks ...................................................................................................... 14-15
Loading a Configuration on the Backup Cluster ....................................................... 14-15
Activating a Configuration on the Backup Cluster ................................................... 14-16
Executing ARX Cluster Failback .................................................................................... 14-17
Conflict Resolution For Replicated Configurations ........................................................... 14-18
Resolving Top-Level Conflicts ....................................................................................... 14-18
Resolving Conflicts in Namespaces .............................................................................. 14-19
Index
xvi
Table of Contents
xviii
1
Introduction
• Overview
• The ARX
• Audience for this Manual
• Using this Manual
• Document Conventions
• CLI Overview
• Getting Started
• Sample Network
• Contacting Customer Service
Overview
Overview
This manual contains instructions and best practices for troubleshooting and
maintaining the Adaptive Resource Switch (ARX®) after it is fully
connected to the network and running storage services. These instructions
focus on the Command-Line Interface (CLI).
Use this book after the ARX is installed, connected to the IP network, and
serving clients. The platform’s Hardware Installation manual explains how
to install the ARX. You can set up basic networking through a GUI wizard,
or work with the more-advanced CLI features described in ARX® CLI
Network-Management Guide. The GUI provides wizards for configuring
most of the storage features in the ARX; the ARX® CLI
Storage-Management Guide provides procedures and best-practices for
configuring all of them through the CLI.
The ARX
The Adaptive Resource Switch (ARX®) is a highly available and scalable
solution that brings resource awareness to a file storage infrastructure, and
adapts these resources to meet the demands of users and applications in real
time. The ARX provides a file-virtualization layer that aggregates the total
capacity and performance of your file storage. A namespace provides
location-independent, transparent mapping of user requests onto the
appropriate storage resource. You can configure policies that the switch
enforces for the placement, replication and migration of files. Through
policy configuration, the ARX adapts to the real-time demands of users and
applications. The ARX thereby serves as a resource proxy for the files and
services behind it.
Back-end Storage and Servers
The Adaptive Resource Switch aggregates heterogeneous file systems and
storage into a unified pool of file storage resources. Through this
unification, you can manage these resources to adapt to user demands and
client applications. File storage assets can be differentiated based on
user-defined attributes, enabling a class-of-storage model. You can reclaim
stranded capacity through policy implementation for more effective storage
utilization, and you can add capacity without disruption. Back-end resources
are monitored for availability and performance, as well as user-access
patterns that drive policy decisions.
CLI Maintenance Guide
1-3
Chapter 1
Introduction
Front-end Services
The Adaptive Resource Switch acts as an in-band file proxy for the Network
File System (NFS) and Microsoft's Common Internet File System (CIFS)
protocols.
Front-end services provide the file virtualization layer that masks the
physical file storage from the user and application. The switch becomes the
file access point, as opposed to the actual physical resource, providing file
access through a namespace. Users and applications maintain a single
consistent file path that is transparently mapped to the proper physical
resource where the information resides.
Policy
The Adaptive Resource Switch provides policy-based resource switching.
Through policy configuration, you can optimize the placement of files onto
the appropriate storage resources and automatically adapt these resources
based on user and application demand. The ARX performs file replication
and migration based on performance, usage or other life-cycle
characteristics, enabling you to implement a flexible file services strategy.
Examples of policies include: migrating files to reclaim stranded capacity;
migrating files across different tiers of storage based on access patterns
and/or value; and replicating frequently accessed files for performance. The
result is more efficient utilization and greater flexibility in file storage
management.
Resilient Overlay Network (RON)
You can connect multiple ARXes with a Resilient Overlay Network (RON),
which can reside on top of any IP network. This provides a network for
distributing and accessing file storage. ARXes can replicate storage to other
switches in the same RON, updating the replicas periodically as the writable
master files change. This is called a shadow copy, where a source volume on
one switch periodically copies its files to one or more shadow volumes on
other switches. Clients can access the shadow volumes at multiple
geographic locations, independent to where the source volume resides.
Audience for this Manual
This manual is intended for
• network technicians responsible for layer 1 and 2 networks,
• network engineers responsible for the Internet Protocol (IP) layer (layer
3),
1-4
Using this Manual
• storage engineers who design and manage storage systems (SANs,
NASes, and DASes), and
• crypto officers who manage all of the Critical Security Parameters
(CSPs) of a network.
The text presumes that all readers are comfortable with a command-line
interface (CLI), especially one based on the Cisco IOS.
Using this Manual
This manual contains instructions for maintaining an ARX after it has been
fully installed, it has been fully provisioned, and it has provided service to
your clients. Other manuals explain installation and provisioning. The
Hardware Installation Guide contains instructions to install the switch, set
up its management IP, and prepare it for CLI provisioning. After a
successful installation, a network engineer can then use the ARX Manager
or the ARX® CLI Network-Management Guide to set up all networking
parameters. Finally, a storage engineer can use the GUI wizards or the
ARX® CLI Storage-Management Guide to aggregate storage and set up
storage policies.
The chapters in this manual contain maintenance instructions, such as
1. backing up and restoring client files through the ARX,
2. backing up configuration data with show running-config and similar
commands,
3. performing software upgrades,
4. maintaining the metadata used by managed volumes,
5. reading the syslog and working with other basic-maintenance
facilities,
6. using some network-troubleshooting tools (such as ping),
7. taking down and repairing managed volumes, and
8. powering down the switch for a planned outage.
Document Conventions
This manual uses the following conventions:
this font represents screen input and output;
• bold text represents input, and
• italic text appears for variable input or output.
CLI Maintenance Guide
1-5
Chapter 1
Introduction
this font is used for command-syntax definitions, which use the same rules
for bold and italic.
Command-syntax definitions also use the following symbols:
• [optional-argument] - square brackets ([ ]) surround optional arguments;
• choice1 | choice2 - the vertical bar ( | ) separates argument choices;
• {choice1 | choice2 | choice3} - curly braces ({ }) surround a required
choice;
• [choice1 | choice2]* - an asterisk (*) means that you can choose none of
them, or as many as desired (for example, “choice1 choice2” chooses
both);
• {choice1 | choice2}+ - a plus sign (+) means that you must choose one or
more.
1-6
CLI Overview
CLI Overview
The Command-Line Interface (CLI) has its commands grouped into modes.
Modes are structured as a tree with a single root, exec mode. This section
summarizes the mode structure and explains some CLI conventions.
Exec Mode
When you log into the CLI, you begin in exec mode. If the hostname is
“bstnA,” the prompt appears as shown below:
bstnA>
You can access all global commands (such as show commands) from exec
mode, and you can use the enable command to enter priv-exec mode.
bstnA> enable
Global Commands
You can access global commands from any mode, not just exec. Global
commands include all show commands and terminal-control commands.
Priv-exec Mode
Priv-exec mode has the following prompt:
bstnA#
Priv-exec mode contains chassis-management commands, clock commands,
and other commands that require privileges but do not change the network
or storage configuration.
Priv-exec has two sub modes, cfg and gbl.
Cfg Mode
To enter cfg mode, use the config command:
bstnA# config
bstnA(cfg)#
Config mode contains all modes and commands for changing the
configuration of the local switch, such as network configuration.
Gbl Mode
To enter gbl mode, use the global command:
bstnA# global
bstnA(gbl)#
Gbl mode controls all parameters that are shared in a redundant pair, such as
namespaces and global servers.
CLI Maintenance Guide
1-7
Chapter 1
Introduction
Exiting a Mode
From any mode, use the exit command to return to its parent mode. From
priv-exec mode, this command exits the CLI; to go from priv-exec mode
back to exec mode, use the no enable command.
From any submode of cfg or gbl mode, you can return immediately to
priv-exec mode by using the end command or pressing <Ctrl-z>.
Prompts
Prompts contain information about your position in the mode hierarchy as
well as the name of the object you are configuring. For example, suppose
you use the following command in gbl mode:
bstnA(gbl)# namespace wwmed
bstnA(gbl‐ns[wwmed])#
This command places you into a new mode, as indicated by the new CLI
prompt. The prompt shows the name of the mode, “gbl-ns,” and the name of
the configuration object, a namespace called “wwmed.” Abbreviations are
used for mode names (for example, “ns” instead of “namespace”) to
conserve space on the command line.
When you descend to lower modes in the config tree, the prompt offers
more information. To extend the previous example, suppose you enter the
following command to configure the “/local” volume in the wwmed
namespace:
bstnA(gbl‐ns[wwmed])# volume /local
bstnA(gbl‐ns‐vol[wwmed~/local])#
The tilde character (~) separates a parent object from its child:
“wwmed~/local” shows that you are in the “/local” volume under the
“wwmed” namespace.
The no Convention
Most config commands have the option to use the “no” keyword to negate
the command. For commands that create an object, the no form removes the
object. For commands that change a default setting, the no form reverts back
to the default. As an example,
bstnA(gbl‐ns[wwmed])# no volume /local
removes the “/local” volume from the “wwmed” namespace.
The enable/no enable Convention
Many objects and configurations require you to enable them using the
enable command before they can take effect. Likewise, many objects and
configurations require you to first disable them using the no enable
command before you can complete a related command or function. The no
1-8
Getting Started
enable command does not remove an object; it only disables it until you
re-enable it. The enable/no enable commands exist in many modes and
submodes in the CLI.
For example, the following command sequence enables the namespace
named “wwmed:”
bstnA(gbl)# namespace wwmed
bstnA(gbl‐ns[wwmed])# enable
bstnA(gbl‐ns[wwmed])# ...
Getting Started
For the initial login, refer to the instructions for booting and configuring the
switch in the appropriate Hardware Installation Guide.
For subsequent logins, use the following steps to log into the F5 CLI:
1. If you are on-site, you can connect a serial line to the serial console
port. This port is labeled ‘Console’ or ‘10101’ (depending on your
ARX platform). By default, the port is set for 9600 baud, 8, N, 1.
You can also telnet to the switch’s management interface. For
example:
telnet 10.10.10.10
In either case, a login prompt appears:
Username:
2. Enter your username and password. For example:
Username: admin
Password: acopia
The CLI prompt appears:
SWITCH>
The name, “SWITCH,” is the default hostname. The hostname is
reset as part of the initial-boot process, so it is likely that yours will
differ.
Entering Cfg or Gbl Mode
The CLI contains two major configuration modes: cfg and gbl. The cfg
mode contains submodes for configuring locally-scoped parameters, only
applicable to the local ARX. These parameters include layer-2, layer-3, and
chassis configuration. Gbl mode applies to configuration that is shared
among both switches in a redundant pair, such as namespaces and global
servers.
After you log into the CLI, use the config command to enter cfg mode:
SWITCH> enable
SWITCH# configure
SWITCH(cfg)#
CLI Maintenance Guide
1-9
Chapter 1
Introduction
To enter gbl mode, use the global command instead:
SWITCH> enable
SWITCH# global
SWITCH(gbl)#
The command sequences in this manual all begin either in cfg mode or gbl
mode.
1 - 10
Sample Network
Sample Network
The examples in this manual draw from a single, fictitious network. This
section shows the topology of the network and the placement of the ARX.
The environment is assumed to be a three-tiered network in a large data
center. The first tier is core routers that provide connectivity to a campus or
WAN. The second tier has redundant distribution switches that distribute all
data-center traffic between the access switches; the access switches
constitute the third tier of the network. All LAN clients, back-end servers,
and back-end filers connect to the access switches, which are layer-2
bridges. Through the access switches and distribution switches, LAN clients
connect to all back-end servers/storage, to one another, and to the WAN.
WAN/campus
core routers
distribution switches
L2 switch
L2 switch
access switches
back-end filers and servers
clients
The sample network has redundant ARXes connected at each of the
distribution switches. Physically, this is a one-armed connection;
conceptually, the ARX has front-end clients in front of it and back-end
servers and filers behind it. To simplify the examples, the access switches
are removed from the remaining illustrations in the book.
CLI Maintenance Guide
1 - 11
Chapter 1
Introduction
The network filers all live on a class-C subnet at 192.168.25.x. These filers
are called back-end filers, since they are the storage behind the front-end
services of the ARX. The filers can be heterogeneous: NAS devices and file
servers (possibly with additional DAS) need only support CIFS or NFS to
be on the back end of the ARX.
DAS
NAS
192.168.25.0/24
DAS
LAN/WAN
clients
1 - 12
Contacting Customer Service
Contacting Customer Service
You can use the following methods to contact F5 Networks Customer
Service:
F5 Networks Online
Knowledge Base
http://support.f5.com
Online repository of answers
to frequently-asked questions.
F5 Networks Services
Support Online
https://websupport.f5.com
Online customer support
request system
Telephone
Follow this link for a list of Support
numbers:
http://www.f5.com/support/support-serv
ices/contact/
CLI Maintenance Guide
1 - 13
Chapter 1
Introduction
1 - 14
2
Configuring Volume Snapshots
• Overview
• Before You Begin
• Creating a Snapshot Rule
• Incorporating a Pre-Existing Snapshot
• Supporting VSS for Pre-XP Clients
• Restricting Access to Snapshots
• Enabling Snapshot Consistency
• Creating a Manual Snapshot
• Verifying a Rule’s Snapshots
• Running Snapshot Operations from a Remote Host
• Showing All ARX Snapshots
• Preparing for Snapshot Reconstitution
• Replica Snapshot Shares
Overview
Overview
An ARX volume can support regular snapshots, or copies from a particular
point in time, of its client files and directories.
Most Microsoft Windows clients can view these snapshots with Windows
Explorer: they can click Properties on any file or directory and select the
Previous Versions tab. The snapshots appear as instances of the same file
or directory with progressively-older time stamps. This is called the Volume
Shadow-copy Service, or VSS, for shared folders:
A Windows client can recover an older version of any file or subdirectory
through the VSS interface.
NFS clients can access snapshots via the “.snapshot” directory in every
directory in a managed volume. This “.snapshot” directory is populated with
a subdirectory for each snapshot that is present, with each snapshot being of
the tree at that location in the managed volume.
The ARX volume coordinates snapshots on multiple back-end filers by
issuing snapshot commands to each of the filers. At least one of the filers
behind the volume must be properly configured to accept the volume’s
snapshot commands, as described below.
The ARX presents only snapshots that it created or that were imported using
the manage snapshot command.
Note
If you add snapshot support to a volume that already has active CIFS
clients, those CIFS clients must close all instances of Windows Explorer for
the Previous Versions tab to appear. Windows Explorer only checks its
network shares for snapshot support during startup.
CLI Maintenance Guide
2-3
Chapter 2
Configuring Volume Snapshots
Before You Begin
The ARX volume must be backed by NetApp filers, Windows servers, Data
Domain systems, and/or EMC Celerra servers that support snapshots or
checkpoints. The Release Notes show the specific releases supported by
ARX snapshots. The volume can also be backed by filers that do not support
snapshots, though shares from these filers are excluded from the
coordinated-ARX snapshot.
Given at least one back-end filer running a supported release, use the
instructions in this section to prepare the filer(s) for snapshot support.
NetApp Configuration
To support ARX snapshots, each NetApp volume must have the nosnapdir
option turned off. From the NetApp CLI, use the vol options command on
each NetApp volume behind the ARX:
vol options vol‐name nosnapdir off
where vol-name identifies the NetApp volume.
For example, the following commands access a NetApp filer named “nas10”
through SSH, and then permit snapshots in two volumes:
juser@mgmt17:~$ ssh root@192.168.25.49
root@192.168.25.49’s password: password
nas10*> vol options datavol1 nosnapdir off
nas10*> vol options datavol2 nosnapdir off
nas10*> ...
WinRM on Windows
The ARX uses the Windows Remote Management (WinRM) service to
manage snapshots on a Windows server. WinRM must be installed on any
Windows server behind a snapshot-supporting volume, and a WinRM
listener must be listening on HTTP port 80.
For a Windows 2003 R2 server, you must add the WinRM service through
the Add/Remove Programs interface, and it installs with an incompatible
default. Configure WinRM on the server to allow for HTTP unencrypted
negotiation. Encrypted HTTP is not supported on this version of the
Windows server. To ensure a high level of security, the ARX uses Kerberos
authentication over HTTP.
To support this Kerberos authentication, the ARX must understand the
Windows-domain hierarchy in the local Active-Directory (AD) forest. See
Discovering the Active-Directory Forest (Kerberos), on page 3-9 of the
ARX® CLI Storage-Management Guide.
2-4
Before You Begin
EMC Celerra Best Practices
We recommend that your ARX volumes contain no more than two EMC
volumes (called “file systems” in EMC documentation) behind any one
EMC management station. EMC-Celerra checkpoints typically take 5-10
seconds when the Celerra is under moderate load, where NetApp snapshots
rarely take longer than 5 seconds. Further, the EMC management station
serializes its checkpoints; if a given management station needs a checkpoint
from file-server A and file-server B at the same time, the file-server-A
checkpoint must finish before the file-server B checkpoint can begin.
EMC Data Domain Best Practices
EMC Data Domain servers provide a unique presentation to NFS clients;
they are only accessible from volume root’s .snapshot directory. The
.snapshot directory under each lower directory does not include the Data
Domain snapshots.
This limitation does not apply to CIFS clients, which can access the
Data-Domain snapshots in every .snapshot directory.
You can avoid this NFS limitation if every directory on the Data Domain
server(s) is striped to another filer type. To ensure universal striping,
migrate all directories in the volume to a share from a different vendor and
promote them to “master:”
• create a filename-fileset that recursively matches everything in the
volume (using path exact / and recurse),
• create a place-rule, and
• use the from (gbl-ns-vol-plc) command to have that fileset match
directories and promote them.
In a tiered volume, you can use this place rule to migrate all master
directories to a Tier 1 share. This is a best practice for Tier 1 volumes.
Creating a Proxy User for Accessing the Filer’s CLI
To invoke snapshots at the back-end filer, the ARX volume requires
administrative privileges at the filer’s CLI. You add the proper
administrative username and password as a proxy user, which typically
holds Windows-client credentials.
For EMC Celerra, EMC Data Domain, and NetApp equipment, these are
UNIX credentials that do not require a Windows domain; they are for SSH
or RSH logins only.
For Windows servers, these credentials require a Windows domain with a
full FQDN, so that they can authenticate with Kerberos.
For example, this command sequence adds a proxy user named
“nas_admin:”
bstnA(gbl)# proxy‐user nas_admin
CLI Maintenance Guide
2-5
Chapter 2
Configuring Volume Snapshots
bstnA(gbl‐proxy‐user[nas_admin])# user root
Password: rootpasswd
Validate Password: rootpasswd
bstnA(gbl‐proxy‐user[nas_admin])# exit
bstnA(gbl)# ...
As another example, this command sequence adds a proxy user named
“cifs_admin” for logging into Windows servers:
bstnA(gbl)# proxy‐user cifs_admin
bstnA(gbl‐proxy‐user[cifs_admin])# user Administrator
Password: adminpasswd
Validate Password: adminpasswd
bstnA(gbl‐proxy‐user[cifs_admin])# windows‐domain MEDARCH.ORG
bstnA(gbl‐proxy‐user[cifs_admin])# exit
bstnA(gbl)# ...
For details on these proxy-user commands and others, see Adding a Proxy
User, on page 3-4 of the ARX® CLI Storage-Management Guide.
Preparing an External-Filer Configuration
The ARX requires parameters for using the CLI or API at each
snapshot-supporting filer. This includes the type of filer (a vendor name)
and proper login credentials for the filer’s CLI or API. The commands for
setting these parameters are described in Preparing the Filer for
ARX-Snapshot Support, on page 6-12 of the ARX® CLI
Storage-Management Guide.
For example, the following command sequence sets up snapshot access for
the “nas10” filer:
bstnA(gbl)# external‐filer nas10
bstnA(gbl‐filer[nas10])# filer‐type network‐appliance management‐protocol rsh
bstnA(gbl‐filer[nas10])# proxy‐user nas_admin
bstnA(gbl‐filer[nas10])# manage snapshots
bstnA(gbl‐filer[nas10])# exit
bstnA(gbl)# ...
As another example, this command sequence sets up snapshot access for the
“fs2” filer, a Windows server:
bstnA(gbl)# external‐filer fs2
bstnA(gbl‐filer[fs2])# filer‐type windows
bstnA(gbl‐filer[fs2])# proxy‐user cifs_admin
bstnA(gbl‐filer[fs2])# manage snapshots
bstnA(gbl‐filer[fs2])# exit
bstnA(gbl)# ...
Creating a Snapshot Rule
An ARX volume can create snapshots on a scheduled basis, so you set it up
as a rule. You can create snapshot rules in managed or direct volumes;
snapshot rules do not require metadata, so direct volumes can support them.
2-6
Creating a Snapshot Rule
However, direct volumes do not support the VSS-client interface;
direct-volume clients access their snapshots through a special “~snapshot”
directory described later in the chapter.
From gbl-ns-vol mode, use the snapshot rule command to create a new
snapshot rule:
snapshot rule name
where name (1-64 characters) is a name you choose for the rule. This
name is used in the names of the rule’s individual snapshots, which can
be viewed by ARX clients.
The CLI prompts for confirmation before creating a new snapshot rule; enter
yes to continue. This puts you into gbl-ns-vol-snap mode, where you enable
the new rule. There are also some optional commands you can invoke from
this mode, such as applying a schedule.
For example, the following command sequence creates an empty snapshot
rule, “dailySnap,” for the volume, “medarcv~/lab_equipment:”
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule dailySnap
This will create a new policy object.
Create object 'dailySnap'? [yes/no] yes
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# ...
Changing the Name of the Snapshot Directory (optional)
If the “.snapshot” directory that is created by default in each directory in the
volume is not named to your liking, you can rename it.
These commands rename the hidden .snapshot directory in every directory
in the current volume:
snapshot directory cifs‐name
snapshot directory nfs‐name
The syntax is:
snapshot directory cifs‐name newdirname
snapshot directory nfs‐name newdirname
where newdirname is the name that will be substituted for .snapshot in every
directory in the current volume.
For example,
snapshot directory nfs‐name ~ckpt
This will substitute the name “~ckpt” for “.snapshot” in every directory in
the current volume.
Take care to avoid specifying a directory name that users might want to use
for regular files or directories.
CLI Maintenance Guide
2-7
Chapter 2
Configuring Volume Snapshots
Changing the Number of Retained Snapshots (optional)
The ARX volume retains a limited number of snapshots for each snapshot
rule. This conserves disk space on each back-end filer. The default is three
snapshots. From gbl-ns-vol-snap mode, use the retain command to change
the number of retained snapshots:
retain number
where number (1-1024) is the number of snapshots to retain. If you
choose a number lower than the current number of snapshots, the
volume removes any excess snapshots the next time the rule runs.
For example, the following command sequence causes the “dailySnap” rule
to retain 5 snapshots:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule dailySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# retain 5
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# ...
Reverting to the Default
Use no retain to keep the default number of snapshots for this rule (three):
no retain
For example:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule hourlySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# no retain
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# ...
Excluding a Share (optional)
The volume may contain one or more shares that should be excluded from
the coordinated snapshot. For example, a share could be backed by a
back-end volume that is approaching a size limit, though the filer has other
volumes where snapshots are permissible. To exclude a single share from
the current snapshot rule, use the exclude command from gbl-ns-vol-snap
mode:
exclude share‐name
where share-name (1-64 characters) identifies the volume share to
exclude. Use the share name from the ARX-volume configuration, not
from the filer configuration; type ? in place of the share-name for a
valid list of share names.
For example, the following command sequence excludes the “backlots”
share from the “hourlySnap” rule:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule hourlySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# exclude backlots
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# ...
2-8
Creating a Snapshot Rule
Including a Formerly-Excluded Share
For a share that was previously excluded, you can use the no exclude
command to include it in future runs of the snapshot rule:
no exclude share‐name
where share-name (1-64 characters) identifies the volume share to
include in future snapshots.
For example, this command sequence ensures that the “leased” share is
included in all future snapshots from the “hourlySnap” rule:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule hourlySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# no exclude leased
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# ...
Sparse Snapshots
A sparse snapshot is a coordinated snapshot with at least one component
snapshot missing. A snapshot rule creates a sparse snapshot if any of the
following conditions exist when the rule runs:
• the rule has any exclude share,
• the volume uses an external-filer with no manage snapshots, or
• the back-end share is unresponsive to snapshot commands.
All of the files on the excluded shares appear to be missing from the client
view of a sparse snapshot. For example, if a file named
“\mydir\mysub\file.txt” is on Share A and another file named
“\mydir\mysub\otherFile.txt” is on an excluded share, a coordinated
snapshot only contains “\mydir\mysub\file.txt” from the included share.
You can use file-placement rules to ensure that files that should be backed
up reside on the volume’s included shares: refer to in Placing Files on
Particular Shares, on page 14-4 of the ARX® CLI Storage-Management
Guide for instructions on creating file-placement rules.
Applying a Schedule (optional)
The ARX volume can create snapshots on a fixed schedule. A schedule is
not required because you can invoke a snapshot rule manually (as described
later in the chapter).
To create a schedule, use the gbl schedule command (refer to Appendix 12,
Creating a Policy Schedule of the ARX® CLI Storage-Management Guide
for details). To apply a schedule to the snapshot rule, use the schedule
command in gbl-ns-vol-snap mode:
schedule name
where name (1-64 characters) identifies the schedule. Use the show
schedule command to list all schedules.
CLI Maintenance Guide
2-9
Chapter 2
Configuring Volume Snapshots
For example, the following command sequence applies a schedule,
“daily4am,” to the “dailySnap” rule:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule dailySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# schedule daily4am
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# ...
You can change to a new schedule by re-running the command.
If the schedule has no specific start time, it starts when you first enable the
snapshot rule (as described later in this section). That is, it takes its first
snapshot at enable time. For instructions on setting the schedule’s start time,
see Setting the Start Time (optional), on page 12-7 of the ARX® CLI
Storage-Management Guide.
Snapshot Grouping
If two or more snapshot rules use the same schedule, the ARX performs all
of their back-end snapshots in a single group. This ensures that there are no
redundant snapshots on any back-end volumes.
Two different schedules with the same timing (for example, two weekly
schedules with the same start times) do not have the same effect on their
snapshot rules.
Important
Snapshot grouping can be problematic for EMC-Celerra-backed volumes.
As mentioned in EMC Celerra Best Practices, on page 2-5, EMC servers
serialize their snapshots (called “checkpoints” in EMC documentation). If
multiple ARX volumes have the same snapshot schedule and use shares from
multiple file systems on an EMC, the ARX waits for the EMC to perform its
checkpoints serially.
For example, suppose 12 ARX volumes have the same snapshot schedule
and are backed by 2 different EMC file systems each (for a total of 24 EMC
file systems). Further suppose that all 24 EMC file systems reside on a
single EMC file server. The EMC server waits for each checkpoint to
complete before it begins the next one. The ARX-snapshot operation is not
complete until all 24 EMC checkpoints are finished, even though each ARX
volume requires only 2 EMC checkpoints.
Removing the Schedule
If you remove the schedule, you can only invoke snapshots manually. Use
no schedule to remove the schedule from the current snapshot rule:
no schedule
For example:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule test_snap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~test_snap])# no schedule
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~test_snap])# ...
2 - 10
Creating a Snapshot Rule
Configuring a Progress Report (optional)
A progress reports shows all the milestones and results of a snapshot. We
recommend this to verify that all filer snapshots succeeded, or to diagnose
problems if one of them failed. From gbl-ns-vol-snap mode, use the report
command to generate this report every time the rule creates a snapshot:
report prefix
where prefix (1-1024 characters) is the prefix to be used for the report.
The report has a name in the following format:
prefix_0_create_YearMonthDayHourMinuteSecondsMilliseconds.rpt
(for example, mySnap_0_create_20071112133047318.rpt for a report
with the “mySnap” prefix).
We recommend some common characters at the start of all your
snapshot-report prefixes, to prepare for snapshot reconstitution
(described later). For example, three snapshot rules could have the
following report prefixes: “snapHourly,” “snapDaily,” and
“snapWeekly.”
Use the show reports command for a list of all reports, or show reports type
Snapshot for a list of snapshot reports. Use show reports report-name to
read the report, show reports status report-name to get a one-line summary
of the report, grep to search through the full report, or tail reports
report-name follow to follow a report as it is being written.
For example, the following command sequence enables a report for the
“dailySnap” rule:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule dailySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# report snap_daily
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# ...
Generating a Report Only When an Error Occurs
To save space on the ARX’s internal disks, you can make the rule skip the
report for snapshots that succeed. To accomplish this, use the optional
error-only flag at the end of the report command:
report prefix error‐only
where prefix is explained above.
For example, the following commands cause the hourlySnap rule to
generate no reports unless there is an error:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule hourlySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# report snap error‐only
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# ...
Disabling Reports
From gbl-ns-vol-snap mode, use no report to prevent the snapshot rule from
generating reports:
no report
CLI Maintenance Guide
2 - 11
Chapter 2
Configuring Volume Snapshots
For example, the following command sequence disables reporting for the
rule, “test_snap:”
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule test_snap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~test_snap])# no report
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~test_snap])# ...
Sample Snapshot-Create Report
The snapshot-create report contains configuration details for each rule,
followed by details about the particular snapshot. The configuration details
are in the first two tables in the report, “Snapshot Summary” and “Snapshot
Properties.” The “Snapshot Summary” table identifies the namespace,
volume, and snapshot rule. The “Snapshot Properties” table shows the
configuration settings for the rule. The “Snapshot Summary - rule-name_0”
table shows timestamps and the status of the coordinated snapshot. The
“Included Shares” section has a separate table for each snapshot on each
back-end share: these show the snapshots’ back-end locations. An
“Excluded Shares” section and/or “Offline Shares” section appears for a
sparse snapshot; these sections list all shares that were not used in the
snapshot operation.
For example, this shows a snapshot-create report from the “dailySnap” rule:
bstnA(gbl)# show reports snap_daily_0_create_20120411005104661.rpt
Snapshot Rule Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace Name: medarcv
Volume Name: /lab_equipment
Snapshot Rule Name: dailySnap
Snapshot Properties
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshots Enabled: Yes
Guarantee Consistency: Disabled
Retain Count: 7
Schedule: daily4am
CIFS Directory Name: ~snapshot
Directory Display: All Exports
Hidden File Attribute: Not Set
Restricted Access Configured: Yes
VSS Mode: None
Contents:
Metadata: No
Volume Configuration: No
User Snapshots: Yes
Archive:
Total Archive Operations: 0
Total Successful Operations: 0
Total Failed Operations: 0
Total Saved Metadata: 0 B
Total Saved Volume Config: 0 B
Average Copy Rate: 0 b/s
Snapshot Summary ‐ dailySnap_0
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshot Name: dailySnap_0
2 - 12
Creating a Snapshot Rule
Snapshot Operation: Create
Result: Success
Time Requested: 04/11/2012 00:51:04 ‐0400
Time Created: 04/11/2012 00:51:04 ‐0400
Last Time Verified:
Request: Create
Snapshot State: Sparse
Snapshot Origin: Manual
Report Name: snap_daily_0_create_20120411005104661.rpt
Included Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: equip (user data)
Filer:
Name: nas10
CIFS Share: equipment
Volume: vol2
Filer Snapshot: acopia_1_201204110451_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol2
Share Name: leased (user data)
Filer:
Name: nas10
CIFS Share: for_lease
Volume: vol1
Filer Snapshot: acopia_1_201204110451_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol1
Share Name: backlots (user data)
Filer:
Name: fs2
CIFS Share: backlot_records
Volume: E:\
Filer Snapshot: {0db33dfa‐b2f9‐45e1‐bb35‐b061c03dd732}
Time Created: 04/11/2012 00:51:07 ‐0400
Excluded Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: scanners
Filer:
Name: fs5
CIFS Share: xraysScanners
Reason: Snapshots were not supported on this type of back‐end filer.
Snapshot Naming on the Filer
The Volume Snapshot fields in the “Included Shares” section show the
names of the snapshot directories on the back-end filers. On EMC servers,
Data Domain systems, and NetApp filers, these are created with the
following format:
acopia_id_time-stamp_uuid_filer-volume
where
id is an integer that the snapshot software uses internally.
time-stamp is in yyyymmddHHMM format. This is the time that the
snapshot was created.
CLI Maintenance Guide
2 - 13
Chapter 2
Configuring Volume Snapshots
uuid is the Universally-Unique ID that identifies the ARX. In a
redundant pair, this is the UUID for the peer that was originally
configured as senior/active, no matter which peer is currently active. An
ARX’s UUID appears in the output of the show chassis chassinfo
command.
filer-volume is the name of the filer’s volume.
A Windows server uses a UUID surrounded by curly braces ({}) to identify
each of its snapshots. For example:
{d316724d‐1e31‐478a‐853a‐1f7d4418c599}
Enabling the Snapshot Rule
The final step in configuring a snapshot rule is to enable it. By default, the
rule is disabled and ignored by policy software. You must enable the rule to
run snapshots on a schedule or to invoke the snapshots manually. Use the
enable command to enable the rule:
enable
For example, the following command sequence enables the “dailySnap”
rule:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule dailySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# enable
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~dailySnap])# ...
Disabling the Rule
Disabling the rule prevents it from creating any snapshots. Use no enable
from gbl-ns-vol-snap mode to disable a snapshot rule:
no enable
For example, the following command sequence disables the “test_snap”
rule:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule test_snap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~test_snap])# no enable
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~test_snap])# ...
Removing all Snapshots Behind a Rule
You can use the priv-exec command, snapshot remove, to delete all of the
back-end snapshots behind a snapshot rule, without removing the rule
configuration. You can use this to clear snapshots from several filers at
once. From priv-exec mode, use the snapshot remove command to remove
the filer snapshots and/or checkpoints behind a snapshot rule:
snapshot remove namespace vol‐path rule
where
namespace (1-30 characters) is the namespace,
2 - 14
Creating a Snapshot Rule
vol-path (1-1024 characters) selects the ARX volume, and
rule (1-64 characters) is the snapshot rule.
The CLI prompts for confirmation before removing the snapshots and/or
checkpoints from the back-end filers. Enter yes to proceed with the snapshot
removal. Then it displays the names of one or more removal reports, one per
ARX snapshot, which show the results of each removal operation. Use show
reports report-name to view any report, or tail reports report-name follow to
watch the removal operation as it progresses.
For example, this command sequence exits to priv-exec mode and removes
all snapshots behind the “hourlySnap” rule:
bstnA(gbl)# end
bstnA# snapshot remove medarcv /lab_equipment hourlySnap
Confirmation of this command results in the removal all snapshots associated with snapshot rule 'hourlySnap' in namespace 'medarcv' volume '/lab_equipment'. The snapshot rule is not deleted.
Proceed? [yes/no] yes
Starting snapshot operation in volume /lab_equipment, report name: snap_hourly_2_remove_20090326082729516.rpt
Starting snapshot operation in volume /lab_equipment, report name: snap_hourly_1_remove_20090326082729516.rpt
Starting snapshot operation in volume /lab_equipment, report name: snap_hourly_0_remove_20090326082729516.rpt
bstnA(gbl)# ...
Removing the Filer Snapshots Behind One ARX Snapshot
You can remove the back-end snapshots from behind a single ARX-volume
snapshot. Add the name of a specific snapshot to the end of the snapshot
remove command:
snapshot remove namespace vol‐path rule snapshot
where
namespace vol-path, and rule are described above, and
snapshot (1-68 characters) is the specific snapshot to remove.
Snapshots are typically named rule-name_n, where rule-name is
the same as rule and n is the number of the specific snapshot (for
example, “hourlySnap_2”). Type ? for a complete list of snapshots
in the current snapshot rule.
The CLI prompts for confirmation before removing the snapshots and/or
checkpoints from the back-end filer(s). Enter yes to proceed with the
snapshot removal. Then it displays the name of the removal report, which
shows the results of the removal operation.
For example, this command sequence exits to priv-exec mode and removes
all filer snapshots behind “dailySnap_2,” an ARX-volume snapshot:
CLI Maintenance Guide
2 - 15
Chapter 2
Configuring Volume Snapshots
bstnA(gbl)# end
bstnA# snapshot remove medarcv /lab_equipment dailySnap dailySnap_2
Confirmation of this command results in the removal of snapshot 'dailySnap_2' created by snapshot rule 'dailySnap' in namespace 'medarcv' volume '/lab_equipment'.
Proceed? [yes/no] yes
Starting snapshot operation in volume /lab_equipment, report name: snap_daily_2_remove_20090326095909994.rpt
bstnA# ...
Sample Snapshot-Remove Report
The snapshot-remove report has a similar format to the snapshot-create
report, shown in Sample Snapshot-Create Report, on page 2-12. This report
contains configuration details for each rule, followed by details about the
particular ARX-snapshot removal. The configuration details are in the first
two tables in the report, “Snapshot Summary” and “Snapshot Properties.”
The “Snapshot Summary” table shows identifies the namespace, volume,
and snapshot rule. The “Snapshot Properties” table shows the configuration
settings for the rule. The “Snapshot Summary - rule-name_0” table shows
timestamps and the status of the overall snapshot removal. The “Included
Shares” section has a separate table for each snapshot on each back-end
share: these show the results and timing of each filer-snapshot removal. If
any of the volume’s shares were administratively excluded from the
snapshot, an “Excluded Shares” section lists them. Similarly, an “Offline
Shares” section appears if any of the volume’s shares were unreachable
when the original snapshot was taken.
For example, this shows a snapshot-remove report from the removal of the
“dailySnap_2” snapshot:
bstnA(gbl)# show reports snap_daily_2_remove_20120411005258066.rpt
Snapshot Rule Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace Name: medarcv
Volume Name: /lab_equipment
Snapshot Rule Name: dailySnap
Snapshot Properties
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshots Enabled: Yes
Guarantee Consistency: Disabled
Retain Count: 7
Schedule: daily4am
CIFS Directory Name: ~snapshot
Directory Display: All Exports
Hidden File Attribute: Not Set
Restricted Access Configured: Yes
VSS Mode: None
Contents:
Metadata: No
Volume Configuration: No
User Snapshots: Yes
2 - 16
Creating a Snapshot Rule
Archive:
Total Archive Operations: 0
Total Successful Operations: 0
Total Failed Operations: 0
Total Saved Metadata: 0 B
Total Saved Volume Config: 0 B
Average Copy Rate: 0 b/s
Snapshot Summary ‐ dailySnap_2
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshot Name: dailySnap_2
Snapshot Operation: Delete
Result: Success
Time Requested: 04/11/2012 00:51:04 ‐0400
Time Created: 04/11/2012 00:51:04 ‐0400
Last Time Verified:
Request: Delete
Snapshot State:
Snapshot Origin: Manual
Report Name: snap_daily_2_remove_20120411005258066.rpt
Included Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: equip (user data)
Filer:
Name: nas10
CIFS Share: equipment
Volume: vol2
Filer Snapshot: acopia_1_201204110451_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol2
Share Name: leased (user data)
Filer:
Name: nas10
CIFS Share: for_lease
Volume: vol1
Filer Snapshot: acopia_1_201204110451_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol1
Share Name: backlots (user data)
Filer:
Name: fs2
CIFS Share: backlot_records
Volume: E:\
Filer Snapshot: {0db33dfa‐b2f9‐45e1‐bb35‐b061c03dd732}
Time Created: 04/11/2012 00:51:07 ‐0400
Excluded Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: scanners
Filer:
Name: fs5
CIFS Share: xraysScanners
Reason: Snapshots were not supported on this type of back‐end filer.
bstnA# ...
CLI Maintenance Guide
2 - 17
Chapter 2
Configuring Volume Snapshots
Removing a Snapshot Rule
Removing a snapshot rule deletes its configuration from the ARX without
affecting any back-end snapshots. This also removes the Previous
Versions tab from the client-side view of the ARX volume.
From gbl-ns-vol mode, use the no snapshot rule command to remove a
snapshot rule from the current volume:
no snapshot rule name
where name (1-64 characters) identifies the rule to remove.
The CLI prompts for confirmation before deleting the snapshot rule. The
confirmation prompt shows all of the individual snapshots that will remain
on the filers after the rule is gone. You will need to access the filer directly if
you decide to remove these snapshots later. Enter yes to continue.
For example, the following command sequence removes the “test_snap”
rule from the “medarcv~/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# no snapshot rule test_snap
The following snapshots are being managed by the rule 'test_snap':
test_snap_2(acopia_7_200707101300_501f705c‐8735‐11d8‐8936‐a58a9e4556df_datavol2)
test_snap_1(acopia_8_200707101400_501f705c‐8735‐11d8‐8936‐a58a9e4556df_datavol2)
test_snap_0(acopia_10_200707101500_501f705c‐8735‐11d8‐8936‐a58a9e4556df_datavol2)
If this command is confirmed, the rule is deleted and all associated data related to the aforementioned snapshots will be removed from the switch. The snapshots on the filers will not be removed.
Proceed? [yes/no] yes
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
Incorporating a Pre-Existing Snapshot
You can incorporate an existing, back-end snapshot into a snapshot rule.
After incorporating all of the pre-existing snapshots into the ARX volume,
Windows clients can access them as they did before the introduction of the
ARX. From priv-exec mode, use the snapshot manage command to import
a back-end snapshot into a snapshot rule:
snapshot manage namespace vol‐path share rule filer‐snap created‐on date‐time
where
namespace (1-30 characters) is the namespace,
vol-path (1-1024 characters) selects the ARX volume, and
share (1-64 characters) is the ARX share. The volume software
seeks the back-end snapshot on the filer behind this share.
rule (1-1024 characters) is the snapshot rule to accept the back-end
snapshot.
2 - 18
Incorporating a Pre-Existing Snapshot
filer-snap (1-255 characters) is name of the snapshot or checkpoint
at the back-end filer or file server.
date-time is the date and time that the ARX snapshot was created,
in mm/dd/yyyy:HH:MM:SS format. This identifies a particular ARX
snapshot from the above rule. You can use show snapshots
(described later) to see the time stamps for existing snapshots. If no
ARX snapshot exists for the given time, this command creates a
new one.
This command runs synchronously; the CLI prompt does not return until the
snapshot import is complete. If it fails, a report name appears. You can use
show reports report-name to examine the report and find the cause of the
failure.
For example, this command sequence exits to priv-exec mode and imports
an existing snapshot (“weekly.1” on the filer behind the “leased” share) into
a rule named “weekly_snap” in the “medarcv~/lab_equipment” volume:
bstnA(gbl)# end
bstnA# snapshot manage medarcv /lab_equipment leased weekly_snap weekly.1 created‐on 03/30/2009:01:05:24
bstnA# ...
Using a Different Prefix for the Error Report
In case of an error, the CLI creates a report. By default, the report name
follows this format:
snapshot-manage-namespace-volume-rule-yyyymmddHHMM.rpt.
To change the “snapshot-manage” prefix, you can use the report-prefix
option at the end of the snapshot-manage command:
snapshot manage namespace ... rule filer‐snap created‐on date‐time [report‐prefix prefix]
where
all options are described above except
prefix (optional, 1-64 characters), which is the new prefix for the
report name.
For example, this command uses a report prefix of “getWk3” for a
manage-snapshot operation, though no report is generated when the
operation succeeds:
bstnA(gbl)# end
bstnA# snapshot manage medarcv /lab_equipment leased weekly_snap weekly.3 created‐on 03/16/2009:01:05:22 report‐prefix getWk3
bstnA# ...
Generating a Report When the Operation Succeeds
The volume software only creates a report when the snapshot manage
operation fails, by default. To create a report whether or not the operation
fails, you can use the verbose option at the end of the command:
CLI Maintenance Guide
2 - 19
Chapter 2
Configuring Volume Snapshots
snapshot manage namespace ... filer‐snap created‐on date‐time [report‐prefix prefix] [verbose]
The CLI shows the report name after you enter the command. For example:
bstnA(gbl)# end
bstnA# snapshot manage medarcv /lab_equipment leased weekly_snap weekly.3 created‐on 03/16/2009:01:05:22 verbose
Results for this operation will be written to the report file snapshot‐manage‐medarcv‐/lab_equipment‐weekly_snap‐200803171422.rpt
bstnA# ...
Clearing the Snapshot from the ARX Configuration
If you mismatched the back-end snapshot with its ARX counterpart, you can
use a command to disassociate the snapshot from the ARX configuration.
From priv-exec mode, the clear snapshot command clears one or more
back-end snapshots from the ARX:
snapshot clear namespace [vol‐path [rule [snapshot snap‐name [share share‐name]]]]
where
namespace (1-30 characters) identifies the namespace where you
want to clear at least one snapshot record.
vol-path (optional, 1-1024 characters) focuses on one ARX
volume. The command clears all snapshot records in the above
namespace if you omit this.
rule (optional, 1-64 characters) is a snapshot rule with one or more
snapshots to clear. If omitted, the command clears all of the
volume’s filer-snapshot records.
snap-name (optional, 1-255 characters) identifies a particular ARX
snapshot where you want to clear filer-snapshot associations. If you
omit this, the command clears the filer-snapshot records for all
retained snapshots in the above rule.
share (optional, 1-64 characters) focuses the command on a single
ARX share. This causes the command to clear the single record of
a particular snapshot on this share. You can use the show
snapshots command to see the exact name of the snapshot on this
share. If you omit this, the command clears the records of all the
filer snapshots associated with the chosen ARX snapshot, and
therefore removes this particular ARX snapshot from the rule.
The CLI prompts for confirmation before clearing any back-end snapshots
from the ARX configuration; enter yes to proceed. This does not affect the
back-end snapshots themselves, nor does it affect the configuration of any
snapshot rule.
For example, the following command clears all of the filer snapshot records
from the “dailySnap_2” snapshot.
bstnA# snapshot clear medarcv /lab_equipment dailySnap snapshot dailySnap_2
Confirmation of this command results in the clearing of snapshot 'dailySnap_2' associated with snapshot rule 'dailySnap' in namespace 'medarcv' volume '/lab_equipment'. This command does not remove the snapshot(s) from the filer(s) in the volume.
2 - 20
Incorporating a Pre-Existing Snapshot
Proceed? [no] yes
bstnA# ...
As a result, the “dailySnap_2” snapshot is entirely cleared from the ARX
database (though the rule configuration is unaffected):
CLI Maintenance Guide
2 - 21
Chapter 2
Configuring Volume Snapshots
Supporting VSS for Pre-XP Clients
This section only applies to a managed volume; direct volumes do not
support VSS for their clients. Skip to the next section if you are configuring
a direct volume.
Windows-2000 client machines use an older software protocol for
exchanging snapshot data, one that requires more server-side processing to
support the “Previous Versions” view of snapshots. Windows XP and later
clients use a newer protocol that simplifies processing for the CIFS server.
To avoid extra processing at the CIFS service, volumes do not support
pre-Windows-XP clients by default. From gbl-ns-vol mode, you can use the
following command to support Windows 2000 clients as well as some later
versions of Windows:
snapshot vss‐mode pre‐xp
Note
This option makes VSS unusable for Windows 7 or later clients. Use this
option only if you have Windows 2000 clients and no Windows 7 or later
clients.
For example, the following command sequence supports VSS for Windows
2000 clients of the “medarcv~/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot vss‐mode pre‐xp
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
Restricting VSS Support to XP and Later Clients
As mentioned above, support of the VSS interface (the Previous Versions
tab in file/directory Properties) incurs a slight performance penalty if
extended to Windows 2000 clients. By default, a volume only supports VSS
for releases after Windows 2000, such as Windows XP and Windows 2003.
Use the following command (also in gbl-ns-vol mode) to return to this
default:
snapshot vss‐mode xp
Note
There is another method for the volume’s Windows-2000 clients to access
snapshots. The volume offers snapshots through a pseudo directory,
“~snapshot.” This directory is described later in the chapter.
For example, the following command sequence edits the “access~/G”
volume and stops VSS support from pre-Windows-XP clients:
bstnA(gbl)# namespace access volume /G
bstnA(gbl‐ns‐vol[access~/G])# snapshot vss‐mode xp
bstnA(gbl‐ns‐vol[access~/G])# ...
2 - 22
Restricting Access to Snapshots
Restricting Access to Snapshots
You have several options for restricting snapshot access:
◆
For CIFS clients, you can identify the administrative clients in a
Windows-Management-Authorization (WMA) group, and limit snapshot
access to those clients.
◆
Also for CIFS clients, you can stop supporting the VSS (“Previous
Versions”) interface altogether.
◆
Leave the “~snapshot” pseudo directory as the only means to access
snapshots. This is the ordinary practice for NFS clients, but may not be
for CIFS clients. This directory exists in every directory in the volume,
but it is not displayed by default. There are four methods for managing
the visibility of the ~snapshot directory:
• For CIFS shares, use WMA groups.
• For NFS or CIFS, display the ~snapshot directory in the root of any
share.
• For NFS or CIFS, Display the ~snapshot directory only in shares that
export the volume root.
• For CIFS shares, use the “Hidden” flag on the ~snapshot directory.
Direct volumes do not support VSS. The ~snapshot directory is the only
means that direct-volume clients have for accessing their snapshots.
You can use any or all of these management options, as described in the
subsections below.
Client-Based Access Control: WMA Groups
You can use a Windows-Management-Authorization (WMA) group to
restrict snapshot access to a limited number of clients, such as
administrators. A WMA group is typically used to identify users who can
use MMC and similar management tools in a namespace. Authorizing
Windows-Management (MMC/Snapshot) Access, on page 3-25 of the ARX®
CLI Storage-Management Guide describes how to create a WMA group,
and Opening Windows-Management Access (optional, MMC/Snapshots), on
page 7-16 describes how to assign one to a namespace. You can create a
WMA group for authorized snapshot clients, permit access to snapshots for
that group, assign it to the volume’s namespace, and then enforce the WMA
group for snapshots in the current volume. All of these steps are described
below.
CLI Maintenance Guide
2 - 23
Chapter 2
Configuring Volume Snapshots
Adding a WMA Group for Snapshots
From gbl mode, you can use the windows-mgmt-auth command to create a
new WMA group. This places you into gbl-mgmt-auth mode, where you can
use the user command once for each Windows client in the WMA group,
and the permit snapshot command to allow them access to snapshots. For
example, this creates a WMA group named “snapViewers” with two users:
bstnA(gbl)# windows‐mgmt‐auth snapViewers
bstnA(gbl‐mgmt‐auth[snapViewers])# user juser windows‐domain MEDARCH.ORG
bstnA(gbl‐mgmt‐auth[snapViewers])# user jquser windows‐domain MEDARCH.ORG
bstnA(gbl‐mgmt‐auth[snapViewers])# permit snapshot monitor
bstnA(gbl‐mgmt‐auth[snapViewers])# exit
bstnA(gbl)# ...
These commands are detailed in Authorizing Windows-Management
(MMC/Snapshot) Access, on page 3-25 of the ARX® CLI
Storage-Management Guide.
Assigning the WMA Group to the Namespace
From gbl-ns mode, you can use another windows-mgmt-auth command to
assign a WMA group to your namespace. For example, this command
sequence assigns the “snapViewers” WMA group to the “medarcv”
namespace:
bstnA(gbl)# namespace medarcv
bstnA(gbl‐ns[medarcv])# windows‐mgmt‐auth snapViewers
bstnA(gbl‐ns[medarcv])# ...
This is described in detail in Opening Windows-Management Access
(optional, MMC/Snapshots), on page 7-16 of the ARX® CLI
Storage-Management Guide.
Restricting Snapshot Access to Members of the WMA Group
The snapshot processes ignore the namespace’s WMA group(s) by default.
From gbl-ns-vol-snap mode, use the snapshot privileged access command
to restrict all snapshot access to privileged Windows users (that is, to users
in a WMA group with permit snapshot monitor):
snapshot privileged‐access
For example, the following command sequence restricts access to all
snapshots in “medarcv~/lab_equipment:”
bstnA(gbl‐ns[medarcv])# volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot privileged‐access
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
Re-Opening Snapshot Access
Use no snapshot privileged-access to allow all users to access the volume’s
snapshots:
no snapshot privileged‐access
This is the default.
2 - 24
Restricting Access to Snapshots
For example, this allows any Windows client to access the snapshots in
“access~/G:”
bstnA(gbl)# namespace access volume /G
bstnA(gbl‐ns‐vol[access~/G])# no snapshot privileged‐access
bstnA(gbl‐ns‐vol[access~/G])# ...
Shutting Down Support for the VSS Interface
You can also limit client access to snapshots by shutting down support for
the VSS interface.
Well-informed clients always have access to the ~snapshot directory, which
is not displayed by default. The ~snapshot directory is a pseudo directory
under every directory of the volume. Each subdirectory under ~snapshot is
one snapshot for the directory, named rule-name_n (such as hourlySnap_0,
hourlySnap_1, and so on). Administrators can traverse these ~snapshot
directories and recover files as needed.
From gbl-ns-vol mode, use the snapshot vss-mode none command to
shut down support for VSS (the “Previous Versions” interface), leaving only
the obscure ~snapshot directory for accessing snapshots:
snapshot vss‐mode none
For example, this command sequence stops VSS access to snapshots in the
“medarcv~/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot vss‐mode none
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
Then use one of the snapshot directory display commands to display the
root ~snapshot directory to administrators. The following subsections
describe these commands.
Displaying the Root ~snapshot Directory
Well-informed clients can use the special ~snapshot directory to access their
snapshots. This is a subdirectory under every directory in the volume. The
volume does not display these pseudo directories by default, but they are
accessible to any user that knows their exact path names.
Note
Direct volumes do not support VSS, so the ~snapshot directory is the only
method that direct-volume clients can use to access their snapshots.
From gbl-ns-vol mode, use the following command to display the ~snapshot
directory in the root of any CIFS share:
snapshot directory display all‐exports
CLI Maintenance Guide
2 - 25
Chapter 2
Configuring Volume Snapshots
If the volume has snapshot privileged-access, described earlier, only
privileged clients can see or access the ~snapshot directories. The ~snapshot
directory appears on the next CIFS dir command or the next refresh of the
graphical view.
For example, the following command sequence shows the ~snapshot
directory in all exports of the “/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot directory display all‐exports
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
Contents of the ~snapshot Directory
The ~snapshot directory contains one subdirectory for each snapshot. Its
subdirectories are named rulename_n, where n is the number of the
snapshot. Snapshot 0 (zero) is the most-recent snapshot, and the numbers are
progressively higher for older snapshots. For example, clients of the
“medarcv~/lab_equipment” volume with the “dailySnap” rule would see
snapshots in directories named dailySnap_0, dailySnap_1, and so on. Every
time the rule runs, it creates a new snapshot and moves it to the “..._0”
directory (dailySnap_0), moves all the intermediate directories (the earlier
dailySnap_0 moves to dailySnap_1, dailySnap_1 moves to dailySnap_2,
and so on), and removes the oldest snapshot. The “Date Modified” stamp for
each directory is the time the snapshot was created.
Displaying ~snapshot Only in Volume-Root Exports
Some installations share out directories below the root of the volume (such
as “lab_equipment\incubators,” “lab_equipment\miscDiags,” and
“lab_equipment\chemlab”) to their CIFS clients, and share out the root of
the volume, “lab_equipment,” to administrators only. This is particularly
popular for home directories. Administrators can use the volume-root export
to maintain all of the clients’ lower-level exports. At these sites, you can
limit access to the snapshot directory by showing it only in the volume-root
export. Administrators who use the volume-root export can see the
“~snapshot” directory, but clients with other exports cannot.
From gbl-ns-vol mode, use the following command to show the snapshot
directory in root exports only:
snapshot directory display volume‐root‐only
As above, this change is visible to clients (that is, the ~snapshot directory
appears) on the client’s next CIFS dir command (or the next refresh of the
graphical view).
For example, the following command sequence restricts snapshots to
volume-root exports of the “medarcv~/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot directory display volume‐root‐only
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
2 - 26
Restricting Access to Snapshots
Setting the “Hidden” Flag for the Snapshot Directory
You can further obscure the snapshot directory by raising its DOS “hidden”
flag. Windows clients who are configured to view this type of “hidden”
directory can see it, while other clients cannot.
Add the optional hidden argument to the end of the snapshot directory
display command to raise the DOS “hidden” flag for the ~snapshot
directory:
snapshot directory display {all‐exports | volume‐root‐only} hidden
If the volume is active when you run this command, the snapshot directory
disappears from client view on the next CIFS dir command (or the next
refresh of the graphical view).
For example, the following command reveals the ~snapshot directory to the
client application for all exports of “medarcv~/lab_equipment,” but instructs
the client applications to hide the directory from users:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot directory display all‐exports hidden
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
Lowering the “Hidden” Flag
By default, the ~snapshot directory does not have the “hidden” flag raised.
All clients can see the directory at the root of the CIFS share. To lower the
“hidden” flag, re-run the snapshot directory display command without the
hidden argument at the end:
snapshot directory display {all‐exports | volume‐root‐only}
As above, the ~snapshot directory appears on the client’s next CIFS dir
command, or the next refresh of the graphical view.
For example, the following command sequence removes the “hidden” flag
from the “/lab_equipment” volume’s snapshots:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot directory display all‐exports
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
CLI Maintenance Guide
2 - 27
Chapter 2
Configuring Volume Snapshots
Changing the Name of the ~snapshot Directory
The “~snapshot” directories contain subdirectories with one or more
snapshots:
From gbl-ns-vol mode, you can use the snapshot directory name command
to change the name of the volume’s ~snapshot directories:
snapshot directory name new‐name
where new-name (1-32 characters) is the new name for this volume’s
snapshot directory. Avoid any characters that are not supported in CIFS
(any control character, /, \, :, *, >, <, ”, |, or ?). Also avoid any name that
might already be in use by clients.
For example, the following command sequence uses “~checkpt” as the
directory container for snapshots in “medarcv~/lab_equipment:”
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot directory name ~checkpt
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
Reverting to the Default Directory Name
Use no snapshot directory name to return to the default name, “~snapshot:”
no snapshot directory name
For example:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# no snapshot directory name
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
2 - 28
Enabling Snapshot Consistency
Enabling Snapshot Consistency
Use the snapshot consistency command to guarantee snapshot consistency
in the current volume. A consistent snapshot is one with no file or directory
changes between the start and end of the coordinated-snapshot operation.
Consistency is achieved through a VIP fence, which momentarily blocks
client access to the volume’s VIP while the back-end filers perform their
snapshot and checkpoint operations. The fence remains up until the last filer
indicates that its snapshot is complete, or until a timeout expires, whichever
comes first.
Important
This affects all volumes behind the volume’s VIP(s). This is only
recommended for databases or similar applications that need it; consult F5
Support for guidance.
This causes the volume’s next snapshot operation to raise the VIP fence:
snapshot consistency
For example, the following command sequence enables snapshot
consistency in the “medarcv~/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot consistency
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
Fencing Timeouts
The VIP fence stops when the last filer snapshot is finished, or after the
coordinated snapshot times out. The timeout occurs in 1 minute plus 80
seconds per filer snapshot.
If multiple snapshot rules use the same schedule, the ARX invokes their filer
snapshots in a group. This protects against duplicate snapshots on back-end
filers. However, it also extends the fencing timeout, and the time that clients
cannot access any ARX volumes behind the VIP(s). This can be
time-consuming for volumes backed by EMC Celerra servers, as discussed
earlier (recall Snapshot Grouping, on page 2-10).
Disabling VIP Fencing (and Consistency)
You have the option to disable VIP fencing in the volume, thereby also
disabling snapshot consistency. Without fencing, it is possible for a client to
make changes on one back-end filer while another filer is still taking its
snapshot. This may not be crucial for your installation; for example,
consistency is rarely an issue at a site where clients use snapshots to recover
one or two files at a time.
The policy engine always pauses for a volume during a coordinated
snapshot, whether or not consistency is enabled.
CLI Maintenance Guide
2 - 29
Chapter 2
Configuring Volume Snapshots
For volumes where snapshot consistency is not required, you can use the no
snapshot consistency command to disable VIP fencing:
no snapshot consistency
For example, the following command sequence disables snapshot
consistency in the “medarcv~/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# no snapshot consistency
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
2 - 30
Creating a Manual Snapshot
Creating a Manual Snapshot
You can manually invoke a snapshot rule and create a coordinated snapshot
at any time. From priv-exec mode, use the snapshot create command to
manually invoke a snapshot rule:
snapshot create namespace vol‐path rule [name]
where
namespace (1-30 characters) is the namespace,
vol-path (1-1024 characters) selects the volume, and
rule (1-64 characters) is the snapshot rule to invoke.
name (optional; 1-68 characters) is a name you choose for this
snapshot. By default, the name is rule_0 (for example,
“dailySnap_0”). You cannot choose the name of an existing
snapshot.
The CLI prompts for confirmation. If the rule has a schedule assigned to it
(recall Applying a Schedule (optional), on page 2-9), the confirmation
notifies you that the unscheduled snapshot affects the rule’s retained
snapshots. For a rule with a full count of retained snapshots, this removes
the oldest retained snapshot and creates a new snapshot to replace it. This
breaks the scheduled chain of snapshots, so it is only recommended for
situations where the most-recent snapshot failed.
Enter yes at the prompt in order to proceed with the snapshot. The CLI then
displays the name of the snapshot report; use show reports report-name to
view this report, which contains details about the snapshot operation.
For example, this command sequence exits to priv-exec mode and manually
runs the “dailySnap” rule in the “medarcv~/lab_equipment” volume:
bstnA(gbl)# end
bstnA# snapshot create medarcv /lab_equipment dailySnap
Snapshot rule 'dailySnap' in namespace 'medarcv' volume '/lab_equipment' has a schedule
associated with it. Running this rule may cause existing snapshots to be
removed if the retain count is exceeded by this request.
Proceed? [yes/no] yes
Starting snapshot operation in volume /lab_equipment, report name: snap_daily_0_create_20090327005716287.rpt
bstnA# ...
CLI Maintenance Guide
2 - 31
Chapter 2
Configuring Volume Snapshots
Verifying a Rule’s Snapshots
It is possible for a back-end filer or file server to automatically delete one of
its snapshots or checkpoints, thus corrupting the aggregated snapshot in the
ARX volume. To verify that all snapshots and/or checkpoints still exist
behind a snapshot rule, use the priv-exec snapshot verify command:
snapshot verify namespace vol‐path rule
where
namespace (1-30 characters) is the namespace,
vol-path (1-1024 characters) selects the volume, and
rule (1-64 characters) is the snapshot rule to verify.
The CLI displays the name of the verification report(s), one per snapshot.
Each report contains the results of one snapshot verification. Use show
reports report-name to view any report.
For example, this command sequence exits to priv-exec mode, verifies all of
the snapshots for the “hourlySnap” rule, and shows the report for “snap_0,”
the most-recent snapshot. The report shows that the verification succeeded.
bstnA(gbl)# end
bstnA# snapshot verify medarcv /lab_equipment hourlySnap
Starting snapshot operation in volume /lab_equipment, report name: snap_hourly_2_verify_20091006020708453.rpt
Starting snapshot operation in volume /lab_equipment, report name: snap_hourly_1_verify_20091006020708453.rpt
Starting snapshot operation in volume /lab_equipment, report name: snap_hourly_0_verify_20091006020708453.rpt
bstnA# show reports snap_hourly_0_verify_20091006020708453.rpt
Snapshot Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace Name: medarcv
Volume Name: /lab_equipment
Snapshot Rule Name: hourlySnap
Snapshot Properties
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshots Enabled: Yes
Guarantee Consistency: Disabled
Retain Count: 3
Schedule: hourly
Directory Name: ~snapshot
Directory Display: All Exports
Hidden File Attribute: Not Set
Restricted Access Configured: Yes
VSS Mode: None
Contents:
Metadata: No
Volume Configuration: No
2 - 32
Verifying a Rule’s Snapshots
User Snapshots: Yes
Archive:
Total Archive Operations: 0
Total Successful Operations: 0
Total Failed Operations: 0
Total Saved Metadata: 0 B
Total Saved Volume Config: 0 B
Average Copy Rate: 0 b/s
Snapshot Summary ‐ hourlySnap_0
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshot Name: hourlySnap_0
Snapshot Operation: Verify
Result: Success
Time Requested: Tue Oct 6 02:07:08 2009
Time Created: Tue Oct 6 02:00:00 2009
Last Time Verified: Tue Oct 6 02:07:12 2009
Request: Verify
Snapshot State: Sparse
Snapshot Origin: Schedule
Report Name: snap_hourly_0_verify_20091006020708453.rpt
Included Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: equip (user data)
Filer:
Name: nas10
CIFS Share: equipment
Volume: vol2
Filer Snapshot: acopia_9_200910060600_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol2
Share Name: backlots (user data)
Filer:
Name: fs2
CIFS Share: backlot_records
Volume: E:\
Filer Snapshot: {7435cc35‐80d5‐472f‐a090‐1a32946b3dbd}
Time Created: Tue Oct 6 02:00:01 2009
Share Name: leased (user data)
Filer:
Name: nas10
CIFS Share: for_lease
Volume: vol1
Filer Snapshot: acopia_9_200910060600_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol1
Excluded Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: scanners
Filer:
Name: fs5
CIFS Share: xraysScanners
Reason: Snapshots were not supported on this type of back‐end filer.
bstnA# ...
CLI Maintenance Guide
2 - 33
Chapter 2
Configuring Volume Snapshots
Verifying a Single Snapshot
To focus on a single snapshot, you can add the name of the snapshot to the
end of the snapshot verify command:
snapshot verify namespace vol‐path rule snapshot
where
namespace vol-path, and rule are described above, and
snapshot (1-68 characters) is a specific snapshot. Snapshots are
typically named rule-name_n, where rule-name is the same as rule
and n is the number of the specific snapshot (for example,
“hourlySnap_2”). The n is 0 (zero) for the newest snapshot and
progressively higher for older snapshots. Type ? for a complete list
of snapshots for the current snapshot rule.
The CLI displays the name of the verification report after you enter the
command.
For example, this command sequence exits to priv-exec mode and verifies
“dailySnap_0” snapshot:
bstnA(gbl)# end
bstnA# snapshot verify medarcv /lab_equipment dailySnap dailySnap_0
Starting snapshot operation in volume /lab_equipment, report name: snap_daily_0_verify_20091006020708676.rpt
bstnA# ...
Running Snapshot Operations from a Remote Host
From any remote host that supports the Secure Shell (SSH) protocol, you
can run snapshot create, snapshot remove, or snapshot verify and see the
report(s). Use the following syntax with ssh:
ssh admin‐user@mip “snapshot ...”
where
admin-user is the username for a valid administrative account at
the ARX (use show users to list all of them, as shown in Listing All
Administrative Users, on page 2-14 of the ARX® CLI
Network-Management Guide),
mip is a management-IP address for the ARX (use show interface
mgmt to show the out-of-band management interface, or show
interface vlan to show all in-band management interfaces), and
snapshot ... is the desired snapshot command, described above.
Surround this with quotation marks (““).
The output of the CLI command appears in the local shell. This also works
with all show commands.
2 - 34
Running Snapshot Operations from a Remote Host
For example, the following command sequence runs the snapshot create
command from a remote machine, “mgmt17.”
juser@mgmt17:~$ ssh admin@10.1.1.7 “snapshot create medarcv /lab_equipment dailySnap”
Command>snapshot create medarcv /lab_equipment dailySnap
Starting snapshot operation in volume /lab_equipment, report name: snap_daily_0_create_20090327005822216.rpt
juser@mgmt17:~$ ssh admin@10.1.1.7 “show reports snap_daily_0_create_20120423012706913.rpt”
Command>show reports snap_daily_0_create_20120423012706913.rpt
Snapshot Rule Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace Name: medarcv
Volume Name: /lab_equipment
Snapshot Rule Name: dailySnap
Snapshot Properties
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshots Enabled: Yes
Guarantee Consistency: Disabled
Retain Count: 7
Schedule: daily4am
CIFS Directory Name: ~snapshot
Directory Display: All Exports
Hidden File Attribute: Not Set
Restricted Access Configured: Yes
VSS Mode: None
Contents:
Metadata: No
Volume Configuration: No
User Snapshots: Yes
Archive:
Total Archive Operations: 0
Total Successful Operations: 0
Total Failed Operations: 0
Total Saved Metadata: 0 B
Total Saved Volume Config: 0 B
Average Copy Rate: 0 b/s
Snapshot Summary ‐ dailySnap_0
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshot Name: dailySnap_0
Snapshot Operation: Create
Result: Success
Time Requested: 04/23/2012 01:27:06 ‐0400
Time Created: 04/23/2012 01:27:07 ‐0400
Last Time Verified:
Request: Create
Snapshot State: Sparse
Snapshot Origin: Manual
Report Name: snap_daily_0_create_20120423012706913.rpt
Included Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: equip (user data)
Filer:
Name: nas10
CIFS Share: equipment
CLI Maintenance Guide
2 - 35
Chapter 2
Configuring Volume Snapshots
Volume: vol2
Filer Snapshot: acopia_1_201204230527_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol2
Share Name: leased (user data)
Filer:
Name: nas10
CIFS Share: for_lease
Volume: vol1
Filer Snapshot: acopia_1_201204230527_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol1
Share Name: backlots (user data)
Filer:
Name: fs2
CIFS Share: backlot_records
Volume: E:\
Filer Snapshot: {306db370‐8318‐4ad4‐9d58‐39d80b215e2a}
Time Created: 04/23/2012 01:27:09 ‐0400
Excluded Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: scanners
Filer:
Name: fs5
CIFS Share: xraysScanners
Reason: Snapshots were not supported on this type of back‐end filer.
juser@mgmt17:~$
2 - 36
Showing All ARX Snapshots
Showing All ARX Snapshots
To see the high-level status of all ARX snapshots, use the show snapshots
command:
show snapshots
This shows a separate table of snapshots for every ARX volume. The table
contains one row per snapshot, with the name of the snapshot rule, the name
of the particular ARX snapshot, the time the snapshot was created (or a
status indicator for a failed or in-progress snapshot), and the source of the
snapshot (either a “Schedule” from a snapshot rule or a “Manual”
invocation). The table is empty for volumes without any snapshots. If a
status indicator appears for the Created time (such as “Incomplete”), you
can use the snapshot report (show reports type Snapshot) to localize the
problem.
For example, this shows that the current switch has had four successful
snapshots in the “medarcv~/lab_equipment” volume:
bstnA(gbl)# show snapshots
Namespace: medco
Volume: /vol
Rule Type Name Created Source
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
Namespace: wwmed
Volume: /acct
Rule Type Name Created Source
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
Namespace: medarcv
Volume: /rcrds
Rule Type Name Created Source
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
Namespace: medarcv
Volume: /lab_equipment
Rule Type Name Created Source
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
hourlySnap Snapshot hourlySnap_0 03/14/2012 00:48:57 ‐0400 Manual
hourlySnap Snapshot hourlySnap_1 03/14/2012 00:48:27 ‐0400 Manual
dailySnap Snapshot dailySnap_0 03/14/2012 00:46:59 ‐0400 Manual
dailySnap Snapshot dailySnap_1 03/14/2012 00:46:29 ‐0400 Manual
mirrorSnap Replica mirrorSnap_0 03/14/2012 00:52:40 ‐0400 Manual
mirrorSnap Replica mirrorSnap_1 03/14/2012 00:51:52 ‐0400 Manual
Namespace: medarcv
Volume: /test_results
Rule Type Name Created Source
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
Namespace: insur
Volume: /claims
CLI Maintenance Guide
2 - 37
Chapter 2
Configuring Volume Snapshots
Rule Type Name Created Source
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
mpHourlySnap Snapshot mpHourlySnap_0 03/14/2012 01:06:47 ‐0400 Manual
mpHourlySnap Snapshot mpHourlySnap_1 03/14/2012 01:04:33 ‐0400 Manual
bstnA(gbl)# ...
Focusing on a Single Namespace, Volume, or Rule
You can add some options to show a smaller set of snapshots:
show snapshots [namespace [vol‐path [rule]]]
where
namespace (1-30 characters) selects a namespace,
vol-path (1-1024 characters) narrows the scope to a specific
volume, and
rule (1-1024 characters) narrows the scope further, to a specific
snapshot rule in the volume (for example, ‘dailySnap’).
If you select a particular rule, the output shows the rule’s configuration
details. After the rule has run at least once, its output contains a “Snapshot
Summary - rule-name_n” section for each retained snapshot. The top table
in the Snapshot-summary section shows the time and overall state of the
coordinated snapshot. The “Included Shares” table shows each back-end
share with a component snapshot and the location of the snapshot on that
share. The “Excluded Shares” section shows all shares in the volume that
were administratively excluded from this coordinated snapshot, if there were
any. The “Offline Shares” section, shows all shares that were unreachable at
the time of the snapshot, if there were any. (The “Excluded Shares” and
“Offline Shares” sections only appear if any such shares were omitted from
the snapshot.)
For example, this command focuses on the “hourlySnap” rule, which has
retained two snapshots so far:
bstnA(gbl)# show snapshots medarcv /lab_equipment hourlySnap
Snapshot Rule Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace Name: medarcv
Volume Name: /lab_equipment
Snapshot Rule Name: hourlySnap
Snapshot Properties
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshots Enabled: Yes
Guarantee Consistency: Disabled
Retain Count: 3
Schedule: hourly
CIFS Directory Name: ~snapshot
Directory Display: All Exports
Hidden File Attribute: Not Set
Restricted Access Configured: Yes
VSS Mode: None
2 - 38
Showing All ARX Snapshots
Contents:
Metadata: No
Volume Configuration: No
User Snapshots: Yes
Archive:
Total Archive Operations: 0
Total Successful Operations: 0
Total Failed Operations: 0
Total Saved Metadata: 0 B
Total Saved Volume Config: 0 B
Average Copy Rate: 0 b/s
Snapshot Summary ‐ hourlySnap_0
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshot Name: hourlySnap_0
Time Requested: 03/14/2012 00:48:57 ‐0400
Time Created: 03/14/2012 00:48:57 ‐0400
Last Time Verified:
Request: Idle
Snapshot State: Complete
Snapshot Origin: Manual
Report Name: snap_hourly_0_create_20120314004857655.rpt
Included Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: equip (user data)
Filer:
Name: nas10
CIFS Share: equipment
Volume: vol2
Filer Snapshot: acopia_5_201203140448_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol2
Share Name: leased (user data)
Filer:
Name: nas10
CIFS Share: for_lease
Volume: vol1
Filer Snapshot: acopia_5_201203140448_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol1
Share Name: backlots (user data)
Filer:
Name: fs2
CIFS Share: backlot_records
Volume: E:\
Filer Snapshot: {8bd8cb9e‐409f‐4362‐a710‐b770c85c6cb9}
Time Created: 03/14/2012 00:48:59 ‐0400
Excluded Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: scanners
Filer:
Name: fs5
CIFS Share: xraysScanners
Reason: Snapshots were not supported on this type of back‐end filer.
Snapshot Summary ‐ hourlySnap_1
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Snapshot Name: hourlySnap_1
Time Requested: 03/14/2012 00:48:27 ‐0400
Time Created: 03/14/2012 00:48:27 ‐0400
CLI Maintenance Guide
2 - 39
Chapter 2
Configuring Volume Snapshots
Last Time Verified:
Request: Idle
Snapshot State: Complete
Snapshot Origin: Manual
Report Name: snap_hourly_0_create_20120314004827354.rpt
Included Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: equip (user data)
Filer:
Name: nas10
CIFS Share: equipment
Volume: vol2
Filer Snapshot: acopia_4_201203140448_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol2
Share Name: leased (user data)
Filer:
Name: nas10
CIFS Share: for_lease
Volume: vol1
Filer Snapshot: acopia_4_201203140448_d9bdece8‐9866‐11d8‐91e3‐f48e42637d58_vol1
Share Name: backlots (user data)
Filer:
Name: fs2
CIFS Share: backlot_records
Volume: E:\
Filer Snapshot: {e671c2e5‐9217‐4b62‐903f‐78b39e012c96}
Time Created: 03/14/2012 00:48:28 ‐0400
Excluded Shares
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Share Name: scanners
Filer:
Name: fs5
CIFS Share: xraysScanners
Reason: Snapshots were not supported on this type of back‐end filer.
bstnA(gbl)# ...
2 - 40
Preparing for Snapshot Reconstitution
Preparing for Snapshot Reconstitution
There may be situations where back-end snapshots become disassociated
with their ARX snapshots. For example, someone could accidentally
remove a snapshot rule and want to re-incorporate the back-end snapshots
into a new instance of the rule. As another example, a primary site with an
ARX may fail, and a disaster-recovery site with another ARX would need to
incorporate snapshots in the same way as was done at the primary site.
Re-associating filer snapshots with ARX snapshots is called snapshot
reconstitution.
Snapshot reconstitution is implemented with snapshot reports and a special
Perl script that is provided with ARX software. Copy all of these to an
external device to prepare for reconstitution at a later date. The snapshot
reports contain the names and snapshot times for the back-end snapshots;
these names and times can change with each ARX snapshot, so they should
be copied after each snapshot operation. You can use the at command,
together with some form of the copy command, to regularly send copies of
your snapshot reports to an external host. The ARX® CLI Reference
describes both of these commands in detail.
Copy the reports so that they are converted to XML format; use the format
xml option at the end of the copy command to accomplish this.
Choose a destination host that supports Perl scripts, and that has the
XML::Simple Perl module installed. You can download the Perl module
from the CPAN site:
http://search.cpan.org
For an example of the ARX-CLI syntax, this command sequence sends all
reports that begin with “snap” to a host at 172.16.100.183:
bstnA(gbl)# end
bstnA# config
bstnA(cfg)# at 17:32:51 every 1 day do "copy reports snap* ftp://ftpuser:*@172.16.100.183//var/arxSnapRpts/ format xml"
bstnA(cfg)# ...
You also require a copy of the snap-recon.pl script, provided in the
“software” directory on the ARX. To continue the example, this copies the
script to the same host and directory:
bstnA(cfg)# end
bstnA# copy software snap‐recon.pl ftp://ftpuser:ftpuser@172.16.100.183//var/arxSnapRpts/
bstnA# ...
Maintaining the Repository for Snapshot Reports
The above commands add progressively more reports to the above share, so
you may need to perform occasional maintenance. All snapshot reports have
time stamps in their names, so that they are unique; new reports do not
overwrite the previous versions. The reports are small (roughly 3 Kbytes),
but the share may accumulate very large numbers of them in the fullness of
CLI Maintenance Guide
2 - 41
Chapter 2
Configuring Volume Snapshots
time. The snap-recon.pl script only requires the most-recent set of reports.
We recommend a periodic script or maintenance process to regularly
remove the unnecessary reports.
Reconstituting ARX Snapshots
To reconstitute an ARX snapshot from your snapshot reports, you create a
CLI script, copy it to the ARX, and run it in the ARX CLI. This process
begins on the filer share with the reports, where you build the CLI script by
running the snap-recon.pl script:
snap‐recon.pl ‐‐report‐dir path [‐‐namespace ns [‐‐volume vol‐path [‐‐rule rule‐name
[‐‐target‐ns t‐ns ‐‐target‐vol t‐vol ‐‐target‐rule t‐rule]]]]
[‐‐output‐script script‐name] [‐‐report‐prefix prefix] [‐‐verbose]
where
path is the path to the snapshot reports. This can be a relative path
(such as “../arxReports”) or an absolute path (such as
“/var/arxReports”).
ns (optional) focuses on the snapshots in the given ARX
namespace. From the ARX CLI, you can use show namespace
for a complete list of namespaces, volumes, and snapshot rules.
vol-path (optional if you entered a namespace) focuses on the
snapshots in the given ARX volume. Specify the volume by its
path name, starting with a slash (/); for example, “/rcrds” or
“/acct.”
rule-name (optional if you entered a volume) takes only the
snapshots for a given ARX rule.
--target-ns t-ns --target-vol t-vol --target-rule t-rule (optional if
you entered a rule) edits the final output:
•
t-ns replaces all instances of the --namespace name with this
name. Use this if you want to incorporate the filer snapshots in
a new namespace.
•
t-vol replaces all instances of the --volume path with the path
you enter here.
•
t-rule replaces the rule name selected with the --rule option.
script-name (optional) sets a name for the output script. By default,
the output script is named “snapRecon.cli.”
prefix (optional) changes the report prefixes in the output script.
These are the prefixes used in the output script’s snapshot
manage commands.
verbose (optional) adds the verbose option to all of the output
script’s snapshot manage commands.
The output of this script is an ARX-CLI script, named “snapRecon.cli” by
default.
2 - 42
Preparing for Snapshot Reconstitution
For example, this command sequence runs the snap-recon.pl test from a
Unix host and lists the files in the current directory. The new
“snapRecon.cli” file is shown in bold:
juser@lnx2:/var/arxSnapRpts$ ls
snap_daily_0_create_20090408013001026.xml snap_hourly_0_create_20090408013234784.xml
snap_daily_0_create_20090408013036393.xml snap_hourly_0_create_20090408013305227.xml
snap_daily_0_create_20090408013106820.xml snap‐recon.pl
snap_daily_2_remove_20090408013154370.xml
juser@lnx2:/var/arxSnapRpts$ ./snap‐recon.pl ‐‐report‐dir .
juser@lnx2:/var/arxSnapRpts$ ls
snap_daily_0_create_20090408013001026.xml snap_hourly_0_create_20090408013234784.xml
snap_daily_0_create_20090408013036393.xml snap_hourly_0_create_20090408013305227.xml
snap_daily_0_create_20090408013106820.xml snapRecon.cli
snap_daily_2_remove_20090408013154370.xml snap‐recon.pl
juser@dlnx2:/var/arxSnapRpts$ ...
Viewing the ARX-CLI Script
Here is a sample of the CLI file, a commented list of snapshot manage
commands that re-incorporate the back-end snapshots into their ARX
snapshots:
juser@dlnx2:/var/arxSnapRpts$ cat snapRecon.cli
;
;Snapshot Reconstruction Commands
;
;F5 Networks, Inc.
;Copyright (c) 2009
;All Rights Reserved
;
;Report: snap_daily_0_create_20090408013036393.rpt
;Created: 04/08/2009:01:30:36
;Namespace: medarcv
;Volume: /lab_equipment
;Rule: dailySnap
snapshot manage medarcv /lab_equipment equip dailySnap acopia_2_200904080530_3a5700b6‐6bd6‐11d8‐85d5‐a96dcef11607_vol2 created‐on 04/08/2009:01:30:36
snapshot manage medarcv /lab_equipment backlots dailySnap {b0263932‐0ebf‐49ed‐ae92‐f2f8eaadae64} created‐on 04/08/2009:01:30:36
snapshot manage medarcv /lab_equipment leased dailySnap acopia_2_200904080530_3a5700b6‐6bd6‐11d8‐85d5‐a96dcef11607_vol2 created‐on 04/08/2009:01:30:36
;Report: snap_daily_0_create_20090408013106820.rpt
;Created: 04/08/2009:01:31:06
;Namespace: medarcv
;Volume: /lab_equipment
;Rule: dailySnap
snapshot manage medarcv /lab_equipment equip dailySnap acopia_3_200904080531_3a5700b6‐6bd6‐11d8‐85d5‐a96dcef11607_vol2 created‐on 04/08/2009:01:31:06
snapshot manage medarcv /lab_equipment backlots dailySnap {0d37ab58‐7674‐456a‐89ac‐75af2b1047c2} created‐on 04/08/2009:01:31:06
snapshot manage medarcv /lab_equipment leased dailySnap acopia_3_200904080531_3a5700b6‐6bd6‐11d8‐85d5‐a96dcef11607_vol2 created‐on 04/08/2009:01:31:06
;Report: snap_hourly_0_create_20090408013234784.rpt
;Created: 04/08/2009:01:32:34
;Namespace: medarcv
;Volume: /lab_equipment
;Rule: hourlySnap
CLI Maintenance Guide
2 - 43
Chapter 2
Configuring Volume Snapshots
snapshot manage medarcv /lab_equipment equip hourlySnap acopia_4_200904080532_3a5700b6‐6bd6‐11d8‐85d5‐a96dcef11607_vol2 created‐on 04/08/2009:01:32:34
snapshot manage medarcv /lab_equipment backlots hourlySnap {f351ebf6‐2167‐4368‐92fa‐6b83b90079ce} created‐on 04/08/2009:01:32:34
snapshot manage medarcv /lab_equipment leased hourlySnap acopia_4_200904080532_3a5700b6‐6bd6‐11d8‐85d5‐a96dcef11607_vol2 created‐on 04/08/2009:01:32:34
;Report: snap_hourly_0_create_20090408013305227.rpt
;Created: 04/08/2009:01:33:05
;Namespace: medarcv
;Volume: /lab_equipment
;Rule: hourlySnap
snapshot manage medarcv /lab_equipment equip hourlySnap acopia_5_200904080533_3a5700b6‐6bd6‐11d8‐85d5‐a96dcef11607_vol2 created‐on 04/08/2009:01:33:05
snapshot manage medarcv /lab_equipment backlots hourlySnap {228cc6a0‐0577‐4afa‐95c2‐345020d1311f} created‐on 04/08/2009:01:33:05
snapshot manage medarcv /lab_equipment leased hourlySnap acopia_5_200904080533_3a5700b6‐6bd6‐11d8‐85d5‐a96dcef11607_vol2 created‐on 04/08/2009:01:33:05
;
;END Snapshot Reconstruction Commands
;
juser@dlnx2:/var/arxSnapRpts$ ...
Running the ARX-CLI Script
After you review the CLI script, you copy it to the ARX and run it. From the
ARX CLI, use the copy command to download the script from your external
host to the ARX’s “scripts” directory. For example, this uses FTP to
download the snapRecon.cli script that we created above:
bstnA(cfg)# end
bstnA# copy ftp://ftpuser:ftpuser@172.16.100.183//var/arxSnapRpts/snapRecon.cli scripts snapRecon.cli
bstnA# ...
Once it is copied to the “scripts” directory, use the priv-exec run command
to run it and reconstitute your snapshots. The ARX® CLI Reference
describes the run command in detail. For example, this command runs the
above script:
bstnA# run scripts snapRecon.cli
bstnA# ...
Correcting Any Snapshot Mismatches
A large CLI script may contain errors that mismatch one or more back-end
snapshots with their counterparts on the ARX. To correct this issue, you can
use the snapshot clear command to remove the ARX records for one or
more back-end snapshots, then you can edit and re-run the ARX-CLI script.
For details on the snapshot clear command, recall Clearing the Snapshot
from the ARX Configuration, on page 2-20.
2 - 44
Replica Snapshot Shares
Replica Snapshot Shares
Replica snapshot shares (referred to from here on as “replica-snap shares”)
enable you to create snapshots for data that has been replicated from data on
tier-1 filers. Since the replica snapshots do not occupy storage in the
managed volume on the tier-1 filer, a larger number of snapshots can be
retained, and for longer periods of time, than would be desirable on a tier-1
filer.
Replica-snap shares are supported on Data Domain, EMC, NetApp, and
Windows filers. Replica-snap shares are presented via managed volumes,
and are not supported for direct volumes. They are managed using policy
rules, schedules, and snapshot commands.
Define a replica-snap share by setting the replica-snap attribute for a share
and configuring a rule to populate it with snapshot data.
Replica-Snap Share Configuration
Create a replica-snap share by setting the replica-snap attribute for an
existing share. This attribute can be set only if the share is not enabled.
In gbl-ns-vol-shr mode, the command syntax to set the attribute for the share
is:
replica‐snap
For example:
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~budget])# replica‐snap
Executing the no replica-snap command removes the replica-snap
attribute, disabling the share’s capacity for containing replica snapshots.
Replica-Snap Rule Configuration
Configure a rule for populating a replica-snap share using the snapshot
replica-snap-rule CLI command in gbl-ns-vol mode. This command opens
gbl-ns-vol-replica-snap mode, which provides commands for defining the
rule.
The command syntax is:
snapshot replica‐snap‐rule name
where name identifies the rule that you are defining (up to 1024 characters).
For example, the following command creates a replica snapshot rule named
“acctsnaps” and opens gbl-ns-vol-replica-snap mode:
bstnA(gbl‐ns‐vol[wwmed~/acct])# snapshot replica‐snap‐rule acctsnaps
The “no” form of the command, no snapshot replica-snap-rule name,
disables the specified snapshot rule.
CLI Maintenance Guide
2 - 45
Chapter 2
Configuring Volume Snapshots
Replica Snapshot Mode
The gbl-ns-vol-replica-snap CLI command mode provides the following
commands for defining a replica-snap rule:
• enable: This activates the current replica-snap rule. The command
syntax is:
enable
For example:
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# enable
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# Executing the no enable command de-activates the replica-snap rule.
• exclude: Specify a share to exclude from the snapshots created by this
rule. The command syntax is:
exclude sharename
where sharename identifies a share in the current volume.
For example, the following command excludes a share named “bills”:
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# exclude bills
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# Executing the no exclude sharename negates the exclusion of the
specified share, enabling it to be included in replica-snap shares.
• report: Enable reporting for a specified report prefix for the current
replica-snap rule. The command syntax is:
report reportprefix
where reportprefix is a prefix to include in the names of the resulting
reports to help identify them. The optional error-only argument causes a
report to be generated only if an error occurs during the operation of the
snapshot.
For example, the following command enables the generation of reports
with a prefix of “snapShareError_” when an error occurs during snapshot
creation:
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# report snapShareError_ error‐only
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# Executing the no report command disables reporting for the current
replica-snap rule.
• retain: Specify the number of snapshots to retain for a the current
replica-snap rule.
The command syntax is:
retain number
where number is the maximum number of snapshots to keep on the share,
up to a maximum of 1024.
For example, the following command causes 30 snapshots to be kept:
2 - 46
Replica Snapshot Shares
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# retain 30
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# Executing no retain reverts the retention of replica snapshots to the
default.
• schedule: Specify an existing schedule to associate with the current
replica-snap rule.
The command syntax is:
schedule name
where name identifies a previously-defined schedule.
For example, the following command associates the schedule named
“daily” with the current replica-snap rule:
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# schedule daily
bstnA(gbl‐ns‐vol‐replica‐snap[wwmed~/acct~acctsnaps])# Executing no schedule dissociates the current replica-snap rule from
any schedule.
Displaying Replica Snapshot Information
Execute the show snapshots command to see the current status of one or
more replica-snap rules.
Behavioral Considerations For Replica Snapshot Shares
Replica-snap shares exhibit a number of different characteristics which
should be kept in mind during their use.
General Considerations
The following considerations pertain generally to replica-snap shares in all
circumstances:
• Replica-snap shares are counted toward the ARX’s 64 share per volume
limit. However, the free space on the replica-snap shares is not counted
toward the volume’s total free space.
• At least one managed share must be configured and enabled in a volume
before that volume can be used.
• From a policy standpoint, a managed volume is considered online once
all the managed shares in the volume have completed import, are
enabled, and are online. Replica-snap shares are not considered when
determining this status, regardless of whether they are online or offline,
enabled or disabled.
• Replica-snap shares are marked as such in all reports containing share
summaries.
CLI Maintenance Guide
2 - 47
Chapter 2
Configuring Volume Snapshots
• Replica-snap shares can be removed from the configuration using the no
share command in global-namespace-volume mode. For replica-snap
shares, the no share command does not require or accept the
relocate-dirs, force, or remove-files-entries options. This is the same
as executing a no share command on a direct share. A no share
command can be executed on a replica-snap share whether it is enabled
or not.
• The remove share migrate and remove share no-migrate commands
work if given a replica-snap share as the share being removed. They
ignore any specified relocate and force options, skip the migration step,
and implement the same functionality as the no share command.
• When a replica-snap share is removed from a volume, a
shareRemoveComplete trap is sent to provide notification of the removal
of the share, and to clear any outstanding notifications in the show
health display.
• Some filer-replication applications are volume-level, and copy the entire
contents of the back-end share to the replica-snap share, including the
filer snapshots. This would overwrite any snapshots that the ARX takes
at the replica-snap share, and defeat the snapshot replica-snap-rule. Do
not use volume-level replication to copy the source share’s contents to
the replica-snap share.
CIFS Considerations For Replica-Snap Shares
The following considerations pertain to replica-snap shares in CIFS
environments:
• Replica-snap shares are accessed using the same authorization protocols
specified for the namespace in which they reside.
• To be used with constrained delegation, all filers hosting replica-snap
shares need to be in the same domain as the VIP presenting the
containing volume.
• When replica-snap shares are used with constrained delegation, the same
domain controller configuration must exist for the replica-snap filers as
for filers containing the managed shares.
Subshares
The following considerations pertain to replica-snap shares and subshares:
• Subshares are replicated to the replica-snap share during the snapshot
process. If some subshares cannot be replicated to the replica-snap
shares, an entry is added to the subshare report noting the failure, but the
operation is still considered successful, and the snapshot still executes.
• In order for snapshots that reside on replica-snap shares to be available
via subshares, subshares that exist on the volume being replicated must
be replicated to the replica-snap shares. Since the target file system is
likely to be read-only, the ARX cannot create directories on the
replica-snap shares, only the subshares themselves. The ARX relies on
the replication process to create the directories on the replica-snap shares
that are pointed to by the subshares.
2 - 48
Replica Snapshot Shares
• If a subshare is created via the export command while a volume
containing replica-snap shares is enabled, the subshare subsystem
attempts to create the subshare on all shares, including the replica-snap
share. If the directory does not exist, or the creation fails on any of the
replica-snap share, the failure is noted in the associated subshares report,
but the operation is still considered a success. This provides access to the
snapshot data as soon as possible if the target directory has already been
replicated to the replica-snap share. Since subshares are synchronized at
each snapshot attempt, any failed subshares synchronizations are
resolved during later snapshot attempts.
• The promote subshares and sync subshares functionality also
ignores failures on replica-snap shares, and returns success if the failures
only occur on replica-snap shares.
Access Based Enumeration (ABE)
The following considerations pertain to replica-snap shares and ABE:
• ABE settings are not captured in snapshots, so any updates to ABE
settings on the shares affects the display of the contents of snapshots
taken when different ABE settings were in effect.
• The ABE setting on the volume is synchronized to the replica-snap
shares as part of the share enable process, the same as with managed
shares.
• The cifs access-based-enum <ns> <vol> [force] command also
synchronizes the ABE setting to all replica-snap shares in the volume.
Attribute Replication
The following considerations pertain to replica-snap shares and attribute
replication:
• Depending on the particular replication mechanism used to replicate the
data from the managed shares to the replica-snap shares, security
descriptors and other attribute settings may not be preserved on the
replica-snap share.
Policy Considerations
The following considerations pertain to replica-snap shares and policy:
• Replica snapshots are controlled by their own snapshot rules, known as
“snapshot replica-snap rules.” Snapshot replica-snap rules can be
managed using the same set of commands that pertain to ordinary
snapshots.
• The maximum retention count for virtual snapshots is 1024.
• A separate type of snapshot rule supports taking snapshots of
replica-snap shares. This is the “snapshot replica-snap-rule”. All
handling and processing of the snapshots is done in the same manner as
for other snapshot rules. Management of the snapshots is performed
CLI Maintenance Guide
2 - 49
Chapter 2
Configuring Volume Snapshots
using the regular snapshot commands, and a snapshot replica-snap rule
can be specified as an argument to these commands, as well as the
regular snapshot rule they accept.
• Snapshots on shares excluded from the rule, after snapshots have been
created on that share, stay visible in the snapshot presentation until the
virtual snapshot retention count is hit, and those snapshots are removed
as part of removing the associated virtual snapshots. If the snapshot limit
is hit on an individual filer, the creation of the snapshot on that filer fails,
and is indicated in the snapshot report.
• Rule names for regular snapshot rules and snapshot replica-snap rules
cannot overlap. This is necessary to make snapshot reconstitution work.
• Since snapshot replica-snap rules are targeting shares that are not being
changed by the user, it is not necessary to fence the VIP when creating
snapshots on replica-snap shares. It is desirable to have the schedules for
regular snapshots and replica-snap rules execute at different times to
keep the fence up for as little time as possible.
• All replica-snap shares must be able to take and present snapshots, so
sparse snapshot support is not an issue for replica-snap shares.
Replica-snap shares can be used in a managed volume with managed
shares that do not support snapshots.
• Shadow replication ignores snapshot only-shares in the shadow source.
None of the data on the replica-snap shares in the source is replicated to
the target shadow volumes.
• Share-farms reject replica-snap shares as arguments to the “share”
command. Place rules reject replica-snap shares are arguments to the
“source” and “dest” commands.
Snapshot Rules
The following considerations pertain to replica-snap shares and snapshot
rules:
• Replica-snap shares are not included in regular snapshots, and therefore
do not need to be excluded explicitly from those snapshot rules.
Snapshot replica-snap rule
The following considerations pertain to replica-snap shares and replica-snap
rules:
• The snapshot replica-snap rule causes the automatic skipping of managed
shares during the snapshot process, in the same manner that the snapshot
rule skips the replica-snap shares. You can enter exclude commands for
replica-snap shares in the volume if they wish to put only a subset of the
replica-snap shares into a snapshot replica-snap rule.
• For snapshot replica-snap rules, it is only the user data that ever has a
snapshot taken of it. Also, an archive location cannot be specified in a
snapshot replica-snap rule, as these shares are not used as part of file
tracking, as they have no associated metadata.
2 - 50
Replica Snapshot Shares
Snapshot Reconstitution
The following considerations pertain to replica-snap shares and snapshot
reconstitution:
• Snapshot reconstitution is done via the same mechanism used for
snapshot rules. Each snapshot must be manually programmed into the
ARX via the snapshot manage command. Snapshot reports for
replica-snap shares need to be archived by the user, in the same manner
as reports for snapshots on managed shares. This is necessary for the
snapshot reconstitution script to work correctly.
Snapshot Grouping
The following considerations pertain to replica-snap shares and snapshot
grouping:
• When taking snapshots of replica-snap shares, it is not necessary to raise
the VIP fence.
• The snapshot grouping code determines when a group of snapshots is
only done on replica-snap shares, and does not raise the VIP fence in that
case, regardless of the fence setting in the volume. If replica-snap share
snapshots are grouped with snaps on managed shares, the fence is raised
according to the volume settings.
Subshare Synchronization
The following considerations pertain to replica-snap shares and subshare
synchronization:
• The snapshot daemon synchronizes the subshares on replica-snap shares
before executing the snapshots. If any of the replica-snap shares fail
synchronization, this is noted in the subshare synchronization report, but
it is not considered a failure. Even if synchronization of the subshares to
the replica-snap shares fails, the snapshots of the replica-snap shares are
still taken, but access to snapshots on the replica-snap shares is blocked
for the failed subshare.
• A report is generated by the subshares synchronization, and the name of
the subshares synchronization report is included in the snapshot report.
File History Archive
The following considerations pertain to replica-snap shares and file history
archives:
• Replica-snap shares are not included in the XML configuration output
created for the file-history archive functionality.
CLI Maintenance Guide
2 - 51
Chapter 2
Configuring Volume Snapshots
2 - 52
3
Tracking Files on Your Back-End Storage
• Overview
• Before You Begin
• Creating a File-History Archive
• Storing File History in the Archive
• Showing Historical Configurations
• Showing File History
• Finding a File’s Current Location
• Maintaining a File-History Archive: Listing Records
Overview
Overview
This chapter only applies to managed volumes. Skip this chapter if your site
only supports direct volumes.
File tracking is the process of periodically archiving the back-end locations
of your files so that you can learn where any file was stored on any given
day. Some sites back up and restore their files directly from their back-end
filers, behind the ARX and its managed volumes. These sites use a
data-protection device, called a backup server in this manual, to coordinate
NDMP backups and restores between filers and backup tapes. If a managed
volume migrates files since the most-recent backup operation, you may not
know the filer where the files were backed up. You can use file tracking to
keep records of files as they migrate, and to identify the filer that held any
given file at any given time.
File tracking uses periodic ARX snapshots of a volume’s metadata and
configuration. A volume’s metadata filer must therefore support ARX
snapshots before the volume can support file tracking.
Before You Begin
The managed volume must have its metadata share on a back-end filer that
supports snapshots or checkpoints. The Release Notes show the specific
filers and filer releases supported by ARX snapshots. This section
summarizes the configuration necessary to prepare your metadata share and
its back-end filer.
NetApp Configuration
To support ARX snapshots, each NetApp volume must have the nosnapdir
option turned off. From the NetApp CLI, use the vol options command on
each NetApp volume behind the ARX:
vol options vol‐name nosnapdir off
where vol-name identifies the NetApp volume.
For example, the following commands access a NetApp filer named “nas1”
through SSH, and then permit snapshots in one volume:
juser@mgmt17:~$ ssh root@192.168.25.21
root@192.168.25.21’s password: password
nas1*> vol options vol1 nosnapdir off
nas1*> ...
CLI Maintenance Guide
3-3
Chapter 3
Tracking Files on Your Back-End Storage
EMC Celerra Best Practices
For each EMC management station behind your collective ARX volumes,
we recommend that you use no more than two EMC volumes (called “file
systems” in EMC documentation). For example, if some of your ARX
volumes use client shares and/or metadata shares from the EMC
management station at 1.2.3.4, those ARX shares should draw from two
EMC file systems at most. EMC-Celerra checkpoints typically take 5-10
seconds per file system when the Celerra is under moderate load, where
NetApp snapshots rarely take longer than 5 seconds. Further, the EMC
management station serializes its checkpoints; if a given management
station needs a checkpoint from file-server A and file-server B at the same
time, the file-server-A checkpoint must finish before the file-server B
checkpoint can begin.
Two or more ARX-snapshot rules with the same schedule perform snapshot
grouping, described in Snapshot Grouping, on page 2-10. That is, the ARX
determines the fewest-possible back-end snapshots that it can take to satisfy
all of the concurrent rules. This improves snapshot performance. However,
any single back-end snapshot may end up in a larger group, and may have to
wait for the EMC serialization described in this section.
Creating a Proxy User for Managing the Filer
To invoke snapshots at the volume’s metadata filer, the ARX volume
requires administrative privileges at the filer’s CLI. You enter the proper
administrative username and password as a proxy user. If the metadata
share is hosted by a NetApp or EMC device, these are UNIX credentials for
RSH or SSH logins; they do not require a Windows domain. If the metadata
share is hosted by a Windows Server, the volume uses WinRM to access it:
in this case, the proxy user must have an FQDN to facilitate Kerberos
authentication.
For example, this command sequence creates a proxy user named
“nas_admin” for SSH or RSH logins:
bstnA(gbl)# proxy‐user nas_admin
bstnA(gbl‐proxy‐user[nas_admin])# user root
Password: rootpasswd
Validate Password: rootpasswd
bstnA(gbl‐proxy‐user[nas_admin])# exit
bstnA(gbl)# ...
For details on these proxy-user commands and others, see Adding a Proxy
User, on page 3-4 of the ARX® CLI Storage-Management Guide.
Preparing an External-Filer Configuration
The ARX logs into the CLI at the metadata share’s filer, and requires
parameters for doing so. These parameters include the type of filer
(identified by vendor) and assignment of the proxy-user credentials from
3-4
Before You Begin
above. The commands for setting these parameters are described in
Preparing the Filer for ARX-Snapshot Support, on page 6-12 of the ARX®
CLI Storage-Management Guide.
For example, the following command sequence sets up snapshot access for
the “nas1” filer:
bstnA(gbl)# external‐filer nas1
bstnA(gbl‐filer[nas1])# filer‐type network‐appliance
bstnA(gbl‐filer[nas1])# proxy‐user nas_admin
bstnA(gbl‐filer[nas1])# manage snapshots
bstnA(gbl‐filer[nas1])# exit
bstnA(gbl)# ...
Preparing External Filers Behind the Volume’s Shares
The ARX can also use CLI access for all of the filers behind the managed
volume, the filers that store client data. The managed-volume software uses
this access to find the actual file-system path of the filer’s shares, as opposed
to a CIFS-share name or a virtual NFS-export path that may be used in the
ARX-volume configuration. Standard backup servers use only file-system
paths to identify client files and directories. Therefore, file-tracking software
finds and records real file-system paths. You can use the actual file-system
paths to retrieve backed-up files from your backup servers.
For external filers where the ARX tracks files, use the filer-type command
and the proxy-user command. It is unnecessary to use the manage
snapshots command to support this path-retrieval process:
bstnA(gbl)# external‐filer fs2
bstnA(gbl‐filer[fs2])# filer‐type windows
bstnA(gbl‐filer[fs2])# proxy‐user cifs_admin
bstnA(gbl‐filer[fs2])# exit
bstnA(gbl)# ...
Best Effort for Path Retrieval
The above instructions are a best practice, not a requirement. They ensure
that the file-tracking reports have an actual file-system path for files on
these shares. Without CLI access, the file-tracking software uses a “best
guess” for paths, based on the following:
CLI Maintenance Guide
◆
For CIFS shares, the file-tracking software sends a query to its storage
filer(s), and the query requires Administrator privileges. Specifically, the
proxy user assigned to the namespace must belong to the Administrators
group. Without adequate privileges, the path is blank. For details on
assigning a proxy user to the namespace, see Choosing a CIFS Proxy
User, on page 7-15 of the ARX® CLI Storage-Management Guide.
◆
For NFS shares, each path includes the back-end-export path used in the
gbl-ns-shr filer command. This may be a virtual path on the filer, not an
actual part of the physical file system, so you may need to translate it to
use it with your backup server. For information on the filer command, see
Identifying the Filer and Share, on page 9-34 of the ARX® CLI
Storage-Management Guide.
3-5
Chapter 3
Tracking Files on Your Back-End Storage
Creating a File-History Archive
To track files, an ARX volume periodically records its current state in an
archive. The volume’s current state is defined here as
• a copy of the volume’s configuration, and (typically)
• a snapshot of the volume’s metadata from the same time.
You can search this archive later with various file-tracking queries. The
archive resides on a filer or a managed volume, which requires sufficient
storage space for up to seven years of these file-history records. The filer or
volume that stores these records does not require snapshot or checkpoint
capabilities. It only keeps a copy of the snapshot/configuration records.
From gbl mode, use the file-history archive command to start the process
of configuring one:
file‐history archive name
where name (1-64 characters) is a name you choose for the archive
configuration.
The CLI prompts for confirmation before creating a new archive object;
enter yes to continue. This puts you into gbl-archive mode, where you
choose a filer or managed volume to hold the archive records.
You can create up to 24 file-history archives on an ARX.
For example, the following command sequence creates an empty archive
object, “fileRecordsMed:”
bstnA(gbl)# file‐history archive fileRecordsMed
This will create a new archive.
Create archive 'fileRecordsMed'? [yes/no] yes
bstnA(gbl‐archive[fileRecordsMed])# ...
Choosing a Location for the Archive Data
The most-important step in creating a file-history archive is choosing a
storage location. As mentioned above, the archive can hold up to 7 years of
records. Choose a filer with a large storage capacity. (You can alternatively
choose a volume on this ARX as an archive location; skip to the subsection
below if this is preferable.)
From gbl-archive mode, use the location filer command to choose an
external filer where the archive will reside. The following syntax selects an
NFS export to store the archive:
location filer ext‐filer {nfs3tcp | nfs3} share‐name [path path]
where
ext-filer (1-64 characters) identifies the filer where the archive will
reside. This is the external-filer name for the filer; use show
external-filer for a complete list of configured filers on the ARX.
3-6
Creating a File-History Archive
nfs3tcp | nfs3 are a required choice. The nfs3tcp option is NFSv3
over TCP, and the nfs3 option is NFSv3 over UDP.
share-name (1-64 characters) is the name of the back-end NFS
export where the archive will reside.
path path (optional, 1-1024 characters) chooses a subdirectory to
store the archive.
This syntax chooses a CIFS share for archive storage:
location filer ext‐filer cifs share‐name proxy‐user proxy [path path]
where
ext-filer (1-64 characters) identifies a CIFS-supporting filer.
cifs is a required keyword.
share-name (1-64 characters) is the name of the back-end CIFS
share where the archive will reside.
proxy (1-32 characters) is the name of a proxy-user configuration
(see Adding a Proxy User, on page 3-4 of the ARX® CLI
Storage-Management Guide). The CLI uses the proxy-user
credentials to store archive files on the share-name share. These
credentials require read and write permission at the share; they do
not require Backup Operator or Administrator privileges. Use show
proxy-user for a full list of all proxy users.
path path (optional, 1-1024 characters) chooses a subdirectory to
store the archive.
For example, the following command sequence stores the “fileRecordsMed”
archive on a CIFS share:
bstnA(gbl)# file‐history archive fileRecordsMed
bstnA(gbl‐archive[fileRecordsMed])# location filer fs4 cifs arx_file_archv proxy‐user acoProxy2
bstnA(gbl‐archive[fileRecordsMed])# ...
Storing the Archive in an ARX Volume
You can store the file-history archive in an ARX volume instead of a
particular external filer. If you select a managed volume, the archive can be
distributed among the its back-end filers according to your migration
policies. This can provide an efficient use of space for your expanding
archive.
Note
If you export this archive to clients who do not understand its purpose, the
clients may inadvertently delete important records. We recommend using an
ARX volume or directory that is accessible to management personnel only.
Management access may not even be necessary except on rare occasions.
For instructions on exporting volume storage to clients, see Sharing a
Namespace Volume, on page 11-15 and Exporting a Namespace Volume,
on page 11-4 of the ARX® CLI Storage-Management Guide.
CLI Maintenance Guide
3-7
Chapter 3
Tracking Files on Your Back-End Storage
Use the location namespace command to store the archive on one of the
ARX’s volumes. The file-access protocol(s) and the proxy user are part of
the namespace configuration, so they are not required in this form of the
command:
location namespace name volume vol‐path [path path]
where
name (1-30 characters) is a namespace on the current ARX. Use
show namespace for a list of all available namespaces. If you
choose a multi-protocol (NFS and CIFS) namespace, the archive
uses NFS to store its records.
vol-path (1-1024 characters) selects a volume from the above
namespace. Type a ? character for a list of the namespace’s
volumes.
path path (optional, 1-1024 characters) chooses a subdirectory to
store the archive.
For example, the following command sequence stores the “testFA” archive
on subdirectory of the “wwmed~/acct” volume:
bstnA(gbl)# file‐history archive testFA
bstnA(gbl‐archive[testFA])# location namespace wwmed volume /acct path /fileArchs
bstnA(gbl‐archive[testFA])# ...
Archive File Structure on the Location Filer
The ARX stores its file-history records with the following directory
structure:
/acopia_file_history
/ARX‐name‐ARX‐GUID
/yyyy
/mm
/dd
/namespace‐name
/volume‐name
/namespace‐name
/volume‐name
/dd
...
/mm
...
/yyyy
...
This structure starts at the path given by the location command, described
above. If there is no path, this starts in the root of the ARX volume or filer
share.
3-8
Creating a File-History Archive
For example, the following structure contains 4 days of file records, for
January 28 through January 31:
Moving the Location
As time goes on, a location filer may run low on disk space. For this
situation, you can move the location to a larger filer or to a managed
volume. You begin by using the no location command, which stops the
ARX from writing to the current archive location:
no location
Then manually copy or move the “acopia_file_history” folder to the
destination filer or volume. To complete the migration, run the location
command with the new filer or volume location.
For example, this command sequence removes the location for the
“FHinsur” archive:
bstnA(gbl)# file‐history archive FHinsur
bstnA(gbl‐archive[FHinsur])# no location
bstnA(gbl‐archive[FHinsur])# ...
To continue the example, assume that the administrator logs onto a
management station and moves the “acopia_file_history” directory from the
current archive filer to a CIFS share on the ARX. Suppose that the ARX
share is backed by a new managed volume on the ARX,
“medarcv~/fhStore.” This command moves the location to the root of that
volume:
bstnA(gbl)# file‐history archive FHinsur
bstnA(gbl‐archive[FHinsur])# location namespace medarcv volume /fhStore
bstnA(gbl‐archive[FHinsur])# ...
CLI Maintenance Guide
3-9
Chapter 3
Tracking Files on Your Back-End Storage
Setting a Description for the Archive
You can add a description to the archive for use in some of the show
commands described below. The description can differentiate the archive
from others. From gbl-archive mode, use the description command to add a
description string:
description text
where text is 1-255 characters. Quote the text if it contains any spaces.
For example:
bstnA(gbl)# file‐history archive fileRecordsMed
bstnA(gbl‐archive[fileRecordsMed])# description “archive share for ARX file histories”
bstnA(gbl‐archive[fileRecordsMed])# ...
Removing the Description
From gbl-archive mode, use no description to remove the description string
from the current file-history archive:
no description
For example:
bstnA(gbl)# file‐history archive testFA
bstnA(gbl‐archive[testFA])# no description
bstnA(gbl‐archive[testFA])# ...
Listing All File-History Archives
Use the show file-history archive command to display a list of all the
archives on the current ARX. You can enter this command from any CLI
mode:
show file‐history archive
The output is a table with one row per archive. For example, this shows a
single archive:
bstnA(gbl)# show file‐history archive
Archive Name Description
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
fileRecordsMed archive share for ARX file histories
bstnA(gbl)# ...
Showing One File-History Archive, with Details
For a detailed view of a single file-history archive, identify the archive at the
end of the command:
show file‐history archive name
where name (1-64 characters) identifies the desired archive.
3 - 10
Creating a File-History Archive
The output contains some configuration details followed by a table of the
managed volumes that use this archive. (Later sections explain how to
configure a managed volume to store its file-history in an archive). For
example, this command shows details for the “fileRecordsMed” archive. No
managed volumes use this archive yet:
bstnA(gbl)# show file‐history archive fileRecordsMed
Name: fileRecordsMed
Location: \\192.168.25.29\arx_file_archv
Description: archive share for ARX file histories
Path: /
Protocol: CIFS
Proxy User: acoProxy2
Status: Online
FreeSpace: 1.1 GB
In use by:
Namespace Volume Snapshot Rule
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
bstnA(gbl)# ...
Showing All Archive Configurations
Use the show global-config archive command to show the full
configuration for all archives on the ARX:
show global‐config archive
The output is a list of CLI commands that you can use to create each
archive. For example, this shows the CLI commands required to recreate the
“fileRecordsMed” archive:
bstnA(gbl)# show global‐config archive
;================================ archive ================================
file‐history archive fileRecordsMed
description "archive share for ARX file histories"
location filer fs4 cifs arx_file_archive proxy‐user acoProxy2 path /
exit
bstnA(gbl)# ...
Showing the Configuration for a Particular Archive
To focus on a single file-history archive (on an ARX with several of them),
add the name of the archive to the end of the command:
show global‐config archive name
where name (1-64 characters) identifies the archive to display.
Removing an Archive
If no volumes currently use this archive, you can remove it from the ARX.
From gbl mode, use the no file-history archive command to remove an
archive from the ARX configuration:
no file‐history archive name
CLI Maintenance Guide
3 - 11
Chapter 3
Tracking Files on Your Back-End Storage
where name (1-64 characters) identifies the archive to remove.
For example, the following command removes the “testFA” archive:
bstnA(gbl)# no file‐history archive testFA
bstnA(gbl)# ...
Storing File History in the Archive
The next step in keeping your file history is to create snapshots of your
volume’s metadata and configuration, and to store those snapshots in your
file-history archive. You can set up a snapshot rule to take these types of
snapshots on a regular basis. An earlier chapter explained the CLI
commands for configuring snapshots; recall Appendix 2, Configuring
Volume Snapshots. This section explains the CLI commands for setting up a
snapshot rule for file tracking.
You begin by creating a snapshot rule in the volume where you want to
track files. If a snapshot rule already exists in the volume (for client data),
you can augment that rule to support file tracking. As described above, the
volume must be a managed volume, and its metadata share must reside on a
filer that supports snapshots.
Note
The volume itself may or may not support snapshots for its clients. There is
no requirement for snapshot support on any share except the volume’s
metadata share.
For example, this command sequence enters the “medarcv~/rcrds” volume
and creates a new snapshot rule, “rcrdsArchive:”
bstnA(gbl)# namespace medarcv volume /rcrds
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# snapshot rule rcrdsArchive
This will create a new policy object.
Create object 'rcrdsArchive'? [yes/no] yes
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# ...
Choosing a File-History Archive
From gbl-ns-vol-snap mode, use the archive command to select a
file-history archive for the current snapshot rule:
archive name
where name (1-64 characters) selects an existing archive.
This is the storage depot for up to seven years of file-history data.
For example, the following command sequence selects the
“fileRecordsMed” archive for the “rcrdsArchive” rule:
bstnA(gbl)# namespace medarcv volume /rcrds
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# snapshot rule rcrdsArchive
3 - 12
Storing File History in the Archive
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# archive fileRecordsMed
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# ...
Removing the File-History Archive from the Rule
You can disconnect the current snapshot rule from its file-history archive
with the no archive command. This prevents future snapshots from tracking
any file history. This is the default for a typical snapshot rule, one
configured only for client-data snapshots.
no archive
For example, the following command sequence removes the file-history
archive from a snapshot rule in the “/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# snapshot rule hourlySnap
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# no archive
bstnA(gbl‐ns‐vol‐snap[medarcv~/lab_equipment~hourlySnap])# ...
Selecting the Contents of the Snapshot
A snapshot can contain one or two forms of data:
• user (client) data and/or
• volume-configuration data, possibly with volume metadata.
A snapshot includes user data by default. This is client-accessible data, and
it is not necessary for file-tracking. Volume-configuration data and volume
metadata are the file-history records that you can store in a file-history
archive.
From gbl-ns-vol-snap mode, use the contents command to determine the
contents of this rule’s snapshots:
contents {user‐data | volume‐config [metadata]}
where
user-data selects client-viewable files and directories. This is the
default for a snapshot rule.
volume-config selects the current configuration of the volume.
This stores the mappings of front-end shares to back-end paths.
metadata (optional) chooses the volume’s metadata, too. The
metadata contains the locations of all client files and directories in
the volume.
For a typical file-tracking installation, the snapshot rule contains both the
configuration and the metadata. For example, the following command
sequence selects these contents for the “rcrdsArchive” rule:
bstnA(gbl)# namespace medarcv volume /rcrds
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# snapshot rule rcrdsArchive
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# contents volume‐config metadata
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# ...
CLI Maintenance Guide
3 - 13
Chapter 3
Tracking Files on Your Back-End Storage
Excluding Contents from the Snapshot
You can use no contents to remove either user data or the volume
configuration from this rule’s snapshots:
no contents {user‐data | volume‐config}
where
user-data removes client-viewable files and directories from the
rule’s snapshots.
volume-config removes the volume configuration and metadata
from future snapshots.
A file-tracking application does not require any user data in its snapshots. A
snapshot rule never sends user data to the file-history archive.
For example, the following command sequence removes user data from the
“rcrdsArchive” rule’s snapshots:
bstnA(gbl)# namespace medarcv volume /rcrds
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# snapshot rule rcrdsArchive
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# no contents user‐data
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# ...
Effects on the Metadata Filer
A snapshot rule typically cleans up its metadata snapshot after successfully
copying it to the archive. That is, the rule removes the snapshot from the
filer behind the metadata share. This conserves space on the metadata filer.
If a snapshot rule includes user-data as well as volume metadata, the
metadata filer keeps the same number of snapshots as the user-data filers.
The total number of snapshots is controlled by the rule’s retain directive,
described in Changing the Number of Retained Snapshots (optional), on
page 2-8.
Applying a Schedule (optional)
As described in the chapter about snapshots, the ARX volume can create
snapshots on a regular schedule. A schedule is not required because you can
invoke a snapshot rule manually (recall Creating a Manual Snapshot, on
page 2-31). However, it is recommended for file tracking.
To create a schedule, use the gbl schedule command (refer to Appendix 12,
Creating a Policy Schedule in the ARX® CLI Storage-Management Guide
for details). To apply a schedule to the snapshot rule, use the schedule
command in gbl-ns-vol-snap mode.
The best practice for scheduling is to configure daily snapshots; one
file-tracking record per day is sufficient for most installations. Another good
practice is to choose a non-busy hour for the snapshot. Client access is
blocked by a VIP fence while the snapshot is taking place, and other
volumes in the same namespace may also be blocked. The VIP fence is
discussed in more detail below.
3 - 14
Storing File History in the Archive
For example, the following command sequence applies an early-morning
schedule, “daily4am,” to the “rcrdsArchive” rule:
bstnA(gbl)# namespace medarcv volume /rcrds
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# snapshot rule rcrdsArchive
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# schedule daily4am
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# ...
For detailed instructions on using a schedule in a snapshot rule, refer back to
Applying a Schedule (optional), on page 2-9.
Configuring a Progress Report (optional)
A progress reports shows all the milestones and results of a snapshot. We
recommend this to verify that all filer snapshots succeeded, or to diagnose
problems if one of them failed. From gbl-ns-vol-snap mode, use the report
command to generate this report every time the rule creates a snapshot, or
only when a snapshot has an error:
report prefix [error‐only]
where error-only (optional) causes the snapshot rule to generate reports
if there is an error in the snapshot operation. This is not recommended
for snapshots with client data, as it makes snapshot reconstitution
impossible for client shares. This option is acceptable for snapshots that
are limited to volume configuration and/or metadata, because those
snapshots are archived and do not require reconstitution.
Use the show reports command for a list of all reports, or show reports type
Snapshot for a list of snapshot reports. Use show reports report-name to
read the report, show reports status report-name to get a one-line summary
of the report, grep to search through the full report, or tail reports
report-name follow to follow a report as it is being written.
For example, the following command sequence enables reports for the
“rcrdsArchive” rule, but only for snapshot operations that encounter an
error:
bstnA(gbl)# namespace medarcv volume /rcrds
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# snapshot rule rcrdsArchive
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# report FA_rcrds error‐only
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# ...
For details about snapshot reports, including sample reports, refer back to
Configuring a Progress Report (optional), on page 2-11.
Enabling the Snapshot Rule
The final step in configuring any snapshot rule is to enable it. By default, the
rule is disabled and ignored by policy software. You must enable the rule to
run snapshots on a schedule or to invoke the snapshots manually. As
described in Enabling the Snapshot Rule, on page 2-14, you use the enable
command to enable the rule. For example, the following command sequence
enables the “rcrdsArchive” rule:
bstnA(gbl)# namespace medarcv volume /rcrds
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# snapshot rule rcrdsArchive
CLI Maintenance Guide
3 - 15
Chapter 3
Tracking Files on Your Back-End Storage
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# enable
bstnA(gbl‐ns‐vol‐snap[medarcv~/rcrds~rcrdsArchive])# ...
Client Access During an Archive Operation: the VIP Fence
When the snapshot rule takes a snapshot of the volume’s metadata, the
volume’s clients are unable to modify the metadata until the snapshot is
complete. This raises a VIP fence, which is discussed in Enabling Snapshot
Consistency, on page 2-29. Every VIP that exports this volume puts up a
VIP fence, thus blocking client access to any other volumes behind the same
VIP or VIPs.
We recommend that you choose a metadata filer that can perform fast
snapshot operations. If multiple volumes send their snapshots to a file
archive, we recommend that they have all of their metadata shares backed
by the same filer volume (or a small set of filer volumes), and that the ARX
volumes share the same schedule for their snapshot rules. With the same
schedule and the same filer volume(s), you can take advantage of snapshot
grouping, discussed in Snapshot Grouping, on page 2-10.
Canceling an Archive Operation
You may have a situation where you want to cancel an archive operation.
For example, the target filer may become unresponsive while the snapshot
rule attempts to copy the volume’s metadata.
Note
This command cancels only the archive operation, which copies the volume
configuration and/or metadata to the file-history archive. This has no effect
on the snapshot operation that may be occurring on the volume’s metadata
share.
From priv-exec mode, you can use the cancel snapshot archive command
to cancel an archiving process that is currently underway:
cancel snapshot archive namespace ns volume vol‐path rule rule‐name
where
ns (1-30 characters) selects the namespace,
vol-path (1-1024 characters) is the managed volume, and
rule-name (1-1024 characters) identifies the snapshot rule that is
currently running the archive operation.
The CLI prompts for confirmation before canceling the archive operation.
Enter yes to proceed.
For example, the following command sequence exits to priv-exec mode and
cancels a snapshot-archive that is currently underway:
bstnA(gbl)# end
bstnA# cancel snapshot archive namespace medarcv volume /rcrds rule rcrdsArchive
3 - 16
Storing File History in the Archive
Confirming this command will cause all archiving operations in namespace ''medarcv'' volume ’’/rcrds''
associated with rule ''rcrdsArchive'' to be cancelled. Proceed? [yes/no] yes
bstnA# ...
Removing all Snapshots Behind a Rule
You can use the snapshot remove command to delete all of the back-end
snapshots behind a snapshot rule. If this snapshot rule includes user data as
well as metadata, this also removes any metadata snapshots on the volume’s
metadata filer. This command only removes filer snapshots, not the rule
configuration.
You can skip this section if the snapshot rule only includes volume
configuration and/or metadata (recall Selecting the Contents of the Snapshot,
on page 3-13). If the snapshot rule does not include any user data, the rule
deletes the metadata snapshot as soon as it is successfully copied to the
archive. This prevents the metadata filer from accumulating unnecessary
snapshots.
From priv-exec mode, use the snapshot remove command to remove the
filer snapshots and/or checkpoints behind a snapshot rule and the volume’s
metadata share. Removing all Snapshots Behind a Rule, on page 2-14,
describes this command in detail.
For example, this command sequence exits to priv-exec mode and removes
all snapshots (including any on the metadata share) behind the
“dailyArchive” rule in the “/lab_equipment” volume:
bstnA(gbl)# end
bstnA# snapshot remove medarcv /lab_equipment dailyArchive
Confirmation of this command results in the removal all snapshots associated with snapshot rule 'dailyArchive' in namespace 'medarcv' volume '/lab_equipment'. The snapshot rule is not deleted.
Proceed? [yes/no] yes
Starting snapshot operation in volume /lab_equipment, report name: fileArchive_1_remove_20090106204139315.rpt
Starting snapshot operation in volume /lab_equipment, report name: fileArchive_0_remove_20090106204139315.rpt
bstnA# ...
Removing a Snapshot Rule
Removing a snapshot rule deletes its configuration from the ARX without
affecting any back-end snapshots. If the rule is dedicated to volume
configuration and metadata, the volume’s clients detect no change when it is
removed.
CLI Maintenance Guide
3 - 17
Chapter 3
Tracking Files on Your Back-End Storage
From gbl-ns-vol mode, use the no snapshot rule command to remove a
snapshot rule from the current volume. For details on this command, see
Removing a Snapshot Rule, on page 2-18.
For example, the following command sequence removes the “test_fha” rule
from the “medarcv~/lab_equipment” volume:
bstnA(gbl)# namespace medarcv volume /lab_equipment
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# no snapshot rule test_fha
The following snapshots are being managed by the rule 'test_fra':
test_fha_2(acopia_3_200707101300_501f705c‐8735‐11d8‐8936‐a58a9e4556df_datavol4)
test_fha_1(acopia_14_200707101400_501f705c‐8735‐11d8‐8936‐a58a9e4556df_datavol4)
If this command is confirmed, the rule is deleted and all associated data related to the aforementioned snapshots will be removed from the switch. The snapshots on the filers will not be removed.
Proceed? [yes/no] yes
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
3 - 18
Showing Historical Configurations
Showing Historical Configurations
ARX installations add and change front-end services and back-end filers as
they grow, so that file-history queries for today’s services may not apply to
configurations from the past. For example, suppose that the
“srv1.family.org” service expands into two services in two new domains,
“srv.brother.org” and “srv.sister.org.” Assume this service split occurs in
March. The “srv.sister.org” service did not exist until March, so a later
query about the files “in srv.sister.org as of January 20” cannot succeed.
Before you make a query about January’s services, you need to know which
services existed in January.
For situations where the configuration has remained stable since before the
times you want to query, you can skip to the next section.
For situations where you are unsure of the earlier configuration, you can use
the show virtual path-history command from any mode. This command
only functions after one or more snapshots have archived the volume’s
configuration:
show virtual path‐history time‐frame [report rpt‐prefix] [archive arch‐name] [verbose]
where
time-frame establishes the date(s) for your query. This takes
several forms, discussed in the subsections below.
report rpt-prefix (optional, 1-255 characters) sends the output to a
report. Without this option, the output appears at the CLI prompt.
The report name is in rpt-prefix_archive-name_date-time.rpt
format; the exact name appears after you enter the command. You
can use show reports to list all reports, and show reports
report-name to view any report.
archive arch-name (optional, 1-64 characters) specifies a
particular file-history archive.
verbose (optional) expands the output with further details.
The following subsections describe the options for querying various time
frames.
For a Particular Day
The most straightforward time-frame is a single date, shown in this syntax:
show virtual path‐history date {today | date} [report rpt‐prefix] [archive arch‐name] [verbose]
where
today | date indicates that you want the configuration from a single
day. Use mm/dd/yyyy format for a date.
The remaining options are explained above.
CLI Maintenance Guide
3 - 19
Chapter 3
Tracking Files on Your Back-End Storage
The output contains a block of information for each archived snapshot in the
given time-frame. Each block has a heading, “As of date time,” and contains
configuration information followed by two tables. The configuration
information identifies the file-history archive, the ARX, the global server
that clients accessed to reach their files, and the particular namespace and
volume containing the files. The first table contains one row per volume
share, with the ARX-share name in one column and the share’s back-end
location in the other column. The second table has one row per front-end
export, and maps the name of the client-visible export to its root directory in
the ARX volume.
Note
The ARX volume uses a filer’s CLI to find its back-end-share locations. The
volume software uses CLI-access parameters to find those paths, which are
provided in the external-filer configuration. Recall Preparing External Filers
Behind the Volume’s Shares, on page 3-5. As explained in that section, the
paths are reduced to “best guesses” for any volume shares where the ARX
has no CLI access.
For example, the following command shows the full path history for a single
day, 9/14/2009. This shows an archived snapshot for the
“medarcv~/lab_equipment” volume, followed by another archived snapshot
for the “medarcv~/rcrds” volume. From the Export tables in this output, we
find that the “ac1.medarch.org” has a share named “labs” along with two
other shares, and that it has several additional shares (“ARCHIVES,”
Y2005,” and more) backed by the “/rcrds” volume. These data points will be
useful later, and are shown in bold below:
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# show virtual path‐history date 09/14/2009
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Start date: Sep 14 2009
End date: Sep 14 2009
Archive: All
Verbose: No
As of Sep 14 2009 01:02:00
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume: /lab_equipment
Share Shared Path ‐> Physical Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
equip \\nas10\equipment ‐> /vol/vol2/NTFS‐QTREE/equipment
leased \\nas10\for_lease ‐> /vol/vol1/NTFS‐QTREE/for_lease
backlots \\fs2\backlot_records ‐> e:\exports\backlot_records
scanners \\fs5\xraysScanners ‐> e:\exports\xraysScanners
Export Relative Virtual Path
3 - 20
Showing Historical Configurations
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
labs \
xraysScanners \
acopia#lab_equipment$ \
As of Sep 14 2009 01:07:00
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume: /rcrds
Share Shared Path ‐> Physical Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
rx \\fs4\prescriptions ‐> d:\exports\prescriptions
charts \\fs1\histories ‐> d:\exports\histories
bulk \\fs2\bulkstorage ‐> e:\exports\bulkstorage
Export Relative Virtual Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
ARCHIVES \
Y2005 \2005
bulkstorage \
acopia#rcrds$ \
CELEBS \VIP_wing
Y2004 \2004
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# ...
For a Range of Dates
You can set a start date and/or an end date for the path history’s time frame.
To set a range of dates in this way, use the start-date clause, the end-date
clause, or both. These go in place of the date clause shown above.
This syntax shows all path history from some earlier start date until today:
show virtual path‐history start‐date date [report rpt‐prefix] [archive arch‐name] [verbose]
where date is some day in the past. Use mm/dd/yyyy format. The end
date is today, implicitly.
This shows all path history from the first archived snapshot up until a
particular end date:
show virtual path‐history end‐date {today | date} [report rpt‐prefix] ...
where today | date is the last day in the query. Implicitly, the start date
is the date of the first snapshot in the archive. Use mm/dd/yyyy format
for a date.
This final option combines the two, so that you see all file-path history
between two dates:
show virtual path‐history start‐date date end‐date date [report rpt‐prefix] ...
CLI Maintenance Guide
3 - 21
Chapter 3
Tracking Files on Your Back-End Storage
For example, this command shows all of the path configurations since a
particular date in January. The command creates verbose output and sends it
to a report:
bstnA(gbl)# show virtual path‐history start‐date 01/07/2009 report pathsSinceJan verbose
Generating report: pathsSinceJan_all_20090116063011.rpt
bstnA(gbl)#
As another example, this command shows all path configurations from a
particular archive, “fileRecordsMed.” This display comes from the earliest
snapshot in the archive up to the last one of June 5th:
bstnA(gbl)# show virtual path‐history end‐date 06/05/2009 archive fileRecordsMed
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Start date: Jan 1 1970
End date: Jun 5 2009
Archive: fileRecordsMed
Verbose: No
As of Apr 23 2009 01:27:00
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume: /lab_equipment
Share Shared Path ‐> Physical Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
equip \\nas10\equipment ‐> /vol/vol2/NTFS‐QTREE/equipment
leased \\nas10\for_lease ‐> /vol/vol1/NTFS‐QTREE/for_lease
backlots \\fs2\backlot_records ‐> e:\exports\backlot_records
scanners \\fs5\xraysScanners ‐> e:\exports\xraysScanners
Export Relative Virtual Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
labs \
xraysScanners \
acopia#lab_equipment$ \
As of Apr 23 2009 01:32:00
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume: /rcrds
...
bstnA(gbl)#
3 - 22
Showing Historical Configurations
For a Time Period Leading Up to an End Date
You can also count back from an end date with the show virtual
path-history command. To accomplish this, you specify some number of
days, weeks, months, and so on that lead up to the end date:
show virtual path‐history count {days|weeks|months|quarters|years} before {today | date} ...
where
count (1-100) is the number of days, weeks, or whatever you
choose with the next argument.
days|weeks|...|years indicates the time unit.
today | date is the last day in the query. Use mm/dd/yyyy format for
a date.
the remaining arguments, not shown above, are the ones described
earlier: report, archive, and verbose.
For example, the following command shows all path histories for the past
year from the “fileRecordsMed” archive:
bstnA(gbl)# show virtual path‐history 1 year before today archive fileRecordsMed
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Start date: Sep 14 2008
End date: Sep 14 2009
Archive: fileRecordsmed
Verbose: No
As of Sep 14 2009 01:02:00
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume: /lab_equipment
Share Shared Path ‐> Physical Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
equip \\nas10\equipment ‐> /vol/vol2/NTFS‐QTREE/equipment
leased \\nas10\for_lease ‐> /vol/vol1/NTFS‐QTREE/for_lease
backlots \\fs2\backlot_records ‐> e:\exports\backlot_records
scanners \\fs5\xraysScanners ‐> e:\exports\xraysScanners
Export Relative Virtual Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
labs \
xraysScanners \
acopia#lab_equipment$ \
As of Sep 14 2009 01:07:00
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
CLI Maintenance Guide
3 - 23
Chapter 3
Tracking Files on Your Back-End Storage
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume: /rcrds
Share Shared Path ‐> Physical Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
rx \\fs4\prescriptions ‐> d:\exports\prescriptions
charts \\fs1\histories ‐> d:\exports\histories
bulk \\fs2\bulkstorage ‐> e:\exports\bulkstorage
Export Relative Virtual Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
ARCHIVES \
Y2005 \2005
bulkstorage \
acopia#rcrds$ \
CELEBS \VIP_wing
Y2004 \2004
...
bstnA(gbl)#
3 - 24
Showing File History
Showing File History
With the names of the front-end services and front-end shares in a given
time frame, you can find the back-end locations of the service’s files at that
time. You can find file locations at any given day, as long as the service’s
volume takes and archives more and more of its configuration/metadata
snapshots. The archive can hold several-years worth of volume data, and
you can query a file’s location back to the time of the first snapshot.
From priv-exec mode, use the show file-history virtual-service command
to view the location of a particular file on a particular day. This is the
general syntax of the command:
show file‐history virtual‐service server‐and‐share time‐frame file‐path [options]
where
server-and-share specifies the server name and the share name as
seen by ARX clients during the time-frame. Server and share
names may change over time, so you can use the show virtual
path-history command to find the correct names for that date, as
described above.
time-frame is a time period when the snapshot rule archived the
volume’s configuration and metadata at least once.
file-path is the file or directory to seek.
options (all optional) include search parameters, such as recursion
into subdirectories.
The subsections below describe specific syntax that you can use with this
command.
For a Particular Day
The following syntax searches for one file or directory on a single day:
show file‐history virtual‐service fqdn fe‐share date {today | date} {[file filename] [path path]}
where
fqdn (1-1024 characters) identifies the front-end service that clients
use to access the file. As mentioned above, you can use show
virtual path-history to find a service name that is appropriate to
your date. This can also be the VIP, WINS name, or WINS alias
from the time (all included in the output of show virtual
path-history).
fe-share (1-1024 characters) is the front-end share that clients use
(or used) to access the file. This is case-sensitive for NFS shares
(that is, “thisShare” is different than “THISshare”), but not for
CIFS shares.
date {today | date} is the specific date for which you want the
file’s location. To specify a date other than today, use mm/dd/yyyy
format. A query for today applies to the time of day when the
CLI Maintenance Guide
3 - 25
Chapter 3
Tracking Files on Your Back-End Storage
file-history record was archived; for a file location as of this
minute, use the find command or run a nsck ... report
metadata-only report. Both of these commands are described in
later chapters.
[file filename] [path path] chooses the file or directory to seek.
This is required: you must select the file, the path (a directory), or
both.
•
filename (1-255 characters) is the file itself. This is not case
sensitive: for example, an entry of “myfile.txt” would match
an actual filename of “myFile.txt” or “MYFILE.TXT.” You
can also use wildcard characters and sequences supported by
the wildmat standard: * means 0 or more characters, ? means
any single character, [0-9] means any single digit, [^a-z]
means any single character except a lowercase letter, and so
on. This searches the root directory of the fe-share, or the path
that you specify in the next argument.
•
path is a directory path, relative to the root of the fe-share.
You use forward slashes (/) in an NFS share or a CIFS share:
for example, “myDir/yourDir” is a valid path in any share.
This also supports wildmat expressions.
The output shows the date you have chosen, the configuration of the archive
and ARX service, and a separate table for each snapshot that contains the
file record. For example, if the snapshot rule took three snapshots on the
date you gave, there would be three sub tables. Each sub table shows the
time of the snapshot/archive operation, the file’s namespace and volume, the
file’s back-end share (in “\\external-filer-name\share-name” format), and
the file’s back-end path.
Note
The ARX volume uses a filer’s CLI to find its back-end-share paths. The
volume software uses CLI-access parameters to find those paths, which are
typically provided in the external-filer configuration for
snapshot-supporting filers (recall Preparing External Filers Behind the
Volume’s Shares, on page 3-5). As explained in that section, the paths are
reduced to “best guesses” for any volume shares where the ARX has no CLI
access.
Sample: Finding a Missing File
For example, suppose you receive a trouble ticket indicating an
accidentally-deleted file in the “ac1.medarch.org” service. Someone
accessed the “ARCHIVES” share in that service and accidentally erased the
“2005/planA/a_adams.dat” file. The most-recent backup for your filers
occurred on September 14. This command sequence exits to priv-exec mode
and shows the filer-location of that file on the 14th. The output indicates that
3 - 26
Showing File History
the file was on “fs1” on that date, at “d:\exports\histories\2005\planA.” If
you concatenate the final two fields of the output (highlighted below), you
get a complete path of “d:\exports\histories\2005\a_adams.dat”.
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# end
bstnA# show file‐history virtual‐service ac1.medarch.org ARCHIVES 09/14/2009 today file a_adams.dat path /2005/planA
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Virtual Server: ac1.MEDARCH.ORG
Export: ARCHIVES
Start date: Jun 30 2010
End date: Jun 30 2010
File Name: a_adams.dat
Path: /2005/planA
Archive: All
Case Sensitive: No
Recurse: No
Verbose: No
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive Date/Time: Jun 30 2010 01:11:00
Global Server: ac1.MEDARCH.ORG
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume Path: /rcrds/2005/planA
File Server(s):
Shared Path: \\fs1\histories
Physical Path: d:\exports\histories\2005\planA
File Name: a_adams.dat
bstnA# ...
With Input/Output Options
You have several options at the end of the show file-history command to
control the search parameters and the output. You can use any of these
options at the end of any show file-history virtual-service command:
show file‐history ... [recurse] [case‐sensitive] [verbose] [report rpt‐prefix] [archive arch‐name]
where
recurse (optional) extends the search into subdirectories.
case-sensitive (optional) limits the search to the exact filename or
path that you typed. This means that an entry of “INDEX.html”
does not match the “index.html” file. By default, “INDEX.html”
would match “index.html,” “Index.html,” or any other case
combination.
CLI Maintenance Guide
3 - 27
Chapter 3
Tracking Files on Your Back-End Storage
verbose (optional) expands the output with further details. If you
specify a path with this option, the output is a list of the files in all
matching directories.
report rpt-prefix (optional, 1-255 characters) sends the output to a
report. Without this option, the output appears at the CLI prompt.
The report name is in rpt-prefix_archive-name_date-time.rpt
format; the exact name appears after you enter the command. You
can use show reports to list all reports, and show reports
report-name to view any report.
archive arch-name (optional, 1-64 characters) specifies a
particular file-history archive.
For example, this command searches for instances of “index.html” with
some additional options: this searches recursively, generates verbose output,
and sends the output to a report file.
bstnA(gbl‐ns‐vol[medarcv~/lab_equipment])# end
bstnA# show file‐history virtual‐service ac1.medarch.org labs date today file index.html recurse verbose report indexPaths
Generating report: indexPaths_ac1.medarch.org_labs_20090118063429.rpt
bstnA# ...
For a Range of Dates
You can set a start date and/or an end date for the file’s time frame. To set a
range of dates in this way, use the start-date clause, the end-date clause, or
both. These go in place of the date clause shown above.
This syntax shows file history from some earlier start date until today:
show file‐history virtual‐service fqdn fe‐share start‐date date {[file filename] [path path]} ...
where date is some day in the past. The end date is today, implicitly.
Use mm/dd/yyyy format.
The next syntax shows a file’s history from the first archived snapshot up
until a particular end date:
show file‐history virtual‐service fqdn fe‐share end‐date {today | date} ...
where today | date is the last day in the query. Implicitly, the start date
is the date of the first snapshot in the archive. Use mm/dd/yyyy format
for a date.
This final option combines the two, so that you see the file history between
two dates:
show file‐history virtual‐service fqdn fe‐share start‐date date end‐date {today | date} ...
For example, this command shows all locations for all “index.html” files
since a date in November of 2008:
bstnA(gbl)# end
bstnA# show file‐history virtual‐service ac1.medarch.org labs start‐date 11/12/2008 file index.html recurse
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
3 - 28
Showing File History
Virtual Server: ac1.MEDARCH.ORG
Export: labs
Start date: Nov 12 2008
End date: Jun 30 2010
File Name: index.html
Path:
Archive: All
Case Sensitive: No
Recurse: Yes
Verbose: No
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive Date/Time: Sep 14 2009 01:02:00
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume Path: /lab_equipment
File Server(s):
Shared Path: \\nas10\for_lease
Physical Path: /vol/vol1/NTFS‐QTREE/for_lease
File Name: index.html
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive Date/Time: Sep 14 2009 01:02:00
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume Path: /lab_equipment/acme
File Server(s):
Shared Path: \\nas10\for_lease
Physical Path: /vol/vol1/NTFS‐QTREE/for_lease/acme
File Name: index.html
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive Date/Time: Sep 14 2009 01:02:00
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume Path: /lab_equipment/miscDiags
File Server(s):
Shared Path: \\nas10\equipment
Physical Path: /vol/vol2/NTFS‐QTREE/equipment/miscDiags
File Name: index.html
...
CLI Maintenance Guide
3 - 29
Chapter 3
Tracking Files on Your Back-End Storage
bstnA#
For a Time Period Leading Up to an End Date
You can also count back from an end date with the show file-history
virtual-service command. To accomplish this, you specify some number of
days, weeks, months, and so on that lead up to the end date:
show file‐history virtual‐service fqdn fe‐share count {days|weeks|months|quarters|years} before {today | date} ...
where
count (1-100) is the number of days, weeks, or whatever you
choose with the next argument.
days|weeks|...|years indicates the time unit.
today | date is the last day in the query. Use mm/dd/yyyy format for
a date.
the remaining arguments, not shown above, are the ones described
earlier.
For example, the following command sequence displays the location of a
PDF file in the “labs” share over the last three days:
bstnA(gbl)# end
bstnA# show file‐history virtual‐service ac1.medarch.org labs 3 days before today file reagentlist.pdf recurse
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Virtual Server: ac1.MEDARCH.ORG
Export: labs
Start date: Jun 27 2010
End date: Jun 30 2010
File Name: reagentlist.pdf
Path:
Archive: All
Case Sensitive: No
Recurse: Yes
Verbose: No
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive Date/Time: Jun 30 2010 01:06:00
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume Path: /lab_equipment/acme
File Server(s):
Shared Path: \\nas10\for_lease
Physical Path: /vol/vol1/NTFS‐QTREE/for_lease/acme
File Name: reagentList.pdf
3 - 30
Showing File History
...
bstnA#
CLI Maintenance Guide
3 - 31
Chapter 3
Tracking Files on Your Back-End Storage
Finding a File’s Current Location
Using a virtual-file path, visible through a VIP, you can find a file’s location
on its actual back-end filer. This is the location of the file now, as opposed
to an earlier location that you can discover with show file-history
commands from above.
From any mode, use the find command to find a file’s current back-end
location:
find host hostname‐or‐vip {cifs | nfs} share‐name path path
where
hostname-or-vip (1-255 characters) is the DNS hostname or VIP
that clients use to access the file (syntax for a WINS name appears
later), To use a hostname defined at an external DNS server, you
must first identify the server with the ip name-server command.
For instructions on using this command, see Configuring DNS
Lookups, on page 4-31 of the ARX® CLI Network-Management
Guide.
{cifs | nfs} share-name (1-4096 characters) is the share that clients
use, and
path (1-4096 characters) specifies the client-visible path to the file.
Use forward slashes (/), even for paths in CIFS shares.
For example, this command discovers that the “a_adams.dat” file from
earlier examples is currently on the filer at 192.168.25.27. The earlier
examples showed this file on a different filer when it was last backed up:
bstnA(gbl)# find global‐server ac1.medarch.org cifs ARCHIVES path /2005/planA/a_adams.dat
Namespace: medarcv
Logical path: /rcrds/2005/planA/a_adams.dat
CIFS Physical location: //192.168.25.27/bulkstorage/2005/planA/a_adams.dat
bstnA(gbl)# ...
For another example, the following command sequence shows two back-end
paths (one through NFS and another through CIFS) to
“\\STATS\carrierCrossCheck.html” at the virtual-IP address,
“192.168.25.15.”
bstnA(gbl)# find host 192.168.25.15 cifs STATS path /carrierCrossCheck.html
Namespace: insur
Logical path: /claims/stats/carrierCrossCheck.html
NFS Physical location: 192.168.25.21:/vol/vol1/NTFS_QTREE/insurance/stats/carrierCrossCheck.html
CIFS Physical location: //192.168.25.21/insurance/stats/carrierCrossCheck.html
bstnA(gbl)# ...
3 - 32
Finding a File’s Current Location
Showing the NFS Filehandles
You can also show the NFS filehandles, both from the client perspective and
the server perspective. Use the optional verbose keyword at the end of the
command to add the filehandles to the output:
find host hostname‐or‐vip {cifs | nfs} share‐name path path verbose
where verbose (optional) adds the NFS filehandles to the output. The
other options were explained above.
This shows both the Virtual File Handle, which is the one that the ARX
presents to NFS clients, and the Physical File Handle, which the ARX
received from the back-end filer.
For example, this shows the location of the carrierCrossCheck.html file
along with its NFS filehandles:
bstnA(gbl)# find host 192.168.25.15 nfs /claims path /stats/carrierCrossCheck.html verbose
Namespace: insur
Logical path: /claims/stats/carrierCrossCheck.html
NFS Physical location: 192.168.25.21:/vol/vol1/NTFS_QTREE/insurance/stats/carrierCrossCheck.html
CIFS Physical location: //192.168.25.21/insurance/stats/carrierCrossCheck.html
NFSv3
Virtual File Handle (32 bytes):
0x000000010c000000090000000000070000000000000000000000000e00000000
Physical File Handle (32 bytes):
0x1e0300000100000084000000fc2293491e030000010000000200000000000000
bstnA(gbl)#
Finding the File with a Global-Server Name
You can also use the global-server name and path to find a file:
find global‐server fqdn {cifs | nfs} share‐name path path [verbose]
where
fqdn (1-255 characters) identifies the global server that clients use
to access the file (for example, “myServer.com”),
{cifs | nfs} share-name (1-4096 characters) is the share that clients
use, and
path (1-4096 characters) specifies the client-visible path to the file.
As above, use forward slashes (/) for all paths.
verbose (optional) adds the file’s NFS filehandles to the output.
For example, the following command sequence shows two back-end paths
to “\\CLAIMS\index.html” on the global server named
“ac1.MEDARCH.ORG:”
bstnA(gbl)# find global‐server ac1.MEDARCH.ORG cifs CLAIMS path /index.html
Namespace: insur
Logical path: /claims/index.html
NFS Physical location: 192.168.25.21:/vol/vol1/NTFS_QTREE/insurance/index.html
CIFS Physical location: The file/directory on //192.168.25.21/insurance has an inconsistent name.
CLI Maintenance Guide
3 - 33
Chapter 3
Tracking Files on Your Back-End Storage
bstnA(gbl)# ...
Finding the File with a WINS Name
A CIFS front-end service can advertise its shares using a NetBIOS name
registered with a WINS server (see Setting the NetBIOS Name (optional,
CIFS), on page 10-7 of the ARX® CLI Storage-Management Guide). If you
used the optional wins-name and/or wins-alias command to set up a special
NetBIOS name, you can use this name to find a file:
find wins netbios‐name {cifs | nfs} share‐name path path [verbose]
where
netbios-name (1-255 characters) identifies a NetBIOS name for a
global server, advertised by a WINS server (for example,
“CIFSSERVER”),
{cifs | nfs} share-name (1-4096 characters) is the share that clients
use, and
path (1-4096 characters) specifies the client-visible path to the file.
As above, use forward slashes (/) for all paths.
verbose (optional) adds the file’s NFS filehandles to the output.
For example, this command finds a file in a front-end service with the WINS
name, “INSURANCE:”
bstnA(gbl)# find wins INSURANCE cifs CLAIMS path /index.html
Namespace: insur
Logical path: /claims/index.html
NFS Physical location: 192.168.25.21:/vol/vol1/NTFS_QTREE/insurance/index.html
CIFS Physical location: The file/directory on //192.168.25.21/insurance has an inconsistent name.
bstnA(gbl)# ...
Finding the File from a Namespace Perspective
You can also use the namespace name and path to find a file:
find namespace namespace path path [verbose]
where
namespace (1-30 characters) identifies the namespace of the file,
path (1-4096 characters) specifies the client-visible path to the file,
and
verbose (optional) adds the file’s NFS filehandles to the output.
This output is sometimes incomplete; use one of the other versions
of the find command (such as find host) to guarantee complete NFS
filehandles.
For example, the following command sequence shows the back-end path to
“/acct/index.html” in the wwmed namespace:
3 - 34
Finding a File’s Current Location
bstnA(gbl)# find namespace wwmed path /acct/index.html
Namespace: wwmed
Logical path: /acct/index.html
NFS Physical location: 192.168.25.19:/exports/budget/index.html
As another example, this command shows the NFS filehandles, too:
bstnA(gbl)# find namespace wwmed path /acct/index.html verbose
Namespace: wwmed
Logical path: /acct/index.html
NFS Physical location: 192.168.25.19:/exports/budget/index.html
(Note: A value of '‐' in the filehandle shows an unknown field.
Choose a different path query type to fill in this information)
NFSv3
Virtual File Handle (24 bytes):
0x000080001400000001000000000002000000000000000000‐‐‐‐‐‐‐‐00000000
Physical File Handle (24 bytes):
0x01000002000800090200000098c08c0033e02b839fc08c00
bstnA(gbl)# ...
CLI Maintenance Guide
3 - 35
Chapter 3
Tracking Files on Your Back-End Storage
Maintaining a File-History Archive: Listing Records
You may wish to monitor the disk space used by file-history records in the
file-history archive. For a list of the records in an archive, you can expand
on the show file-history archive command discussed earlier (recall Listing
All File-History Archives, on page 3-10). Use the name of a particular
archive followed by the contents keyword, a time frame, and possibly some
options:
show file‐history archive name contents time‐frame [namespace ns volume path] [report rpt‐prefix]
where
name (1-64 characters) identifies the desired archive.
contents is a required keyword.
time-frame establishes the date(s) for your query. This takes
several forms, discussed in the subsections below.
ns (optional, 1-30 characters) selects the records from a particular
ARX namespace.
vol-path (optional, 1-1024 characters) focuses on one ARX
volume.
report rpt-prefix (optional, 1-255 characters) sends the output to a
report. Without this option, the output appears at the CLI prompt.
The report name is in rpt-prefix_archive-name_date-time.rpt
format; the exact name appears after you enter the command. You
can use show reports to list all reports, and show reports
report-name to view any report.
The subsections below explain the various time frames that you can specify
for this command.
For a Particular Day
The most straightforward time-frame is a single date, shown in this syntax:
show file‐history archive name contents date {today | date} [namespace ns volume path] ...
where
today | date indicates that you want the archive contents from the
given day. This shows any and all snapshots that were archived
today or on the date you provide. Use mm/dd/yyyy format for a
date.
The remaining options are explained above.
The output contains three tables. The first table shows the chosen date
range, the second lists all the snapshots archived on the given date (one row
per snapshot), and the final table summarizes the total space consumed by
the snapshots shown.
For example, the following command shows the snapshots added to the
“fileRecordsMed” archive on the current day:
3 - 36
Maintaining a File-History Archive: Listing Records
bstnA(gbl)# show file‐history archive fileRecordsMed contents date today
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive: fileRecordsMed
Start date: Jun 30 2010
End date: Jun 30 2010
Namespace:
Volume:
Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
Archive Date/Time Namespace:Volume Snapshot Rule Config Metadata
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
Jun 30 2010 01:06:00 medarcv:/lab_equipment labArchive 2.1 kB 32 kB
Jun 30 2010 01:11:00 medarcv:/rcrds rcrdsArchive 2.2 kB 64 kB
Summary:
Total space consumed by Volume Metadata: 96 kB
Total space consumed by Volume Configuration: 4.3 kB
Grand total space consumed: 100 kB
bstnA(gbl)# ...
For another example, this command focuses on the snapshots for a single
volume today, “medarcv~/rcrds:”
bstnA(gbl)# show file‐history archive fileRecordsMed contents date today namespace medarcv volume /rcrds
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive: fileRecordsMed
Start date: Jun 30 2010
End date: Jun 30 2010
Namespace: medarcv
Volume: /rcrds
Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
Archive Date/Time Namespace:Volume Snapshot Rule Config Metadata
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
Jun 30 2010 01:11:00 medarcv:/rcrds rcrdsArchive 2.2 kB 64 kB
Summary:
Total space consumed by Volume Metadata: 64 kB
Total space consumed by Volume Configuration: 2.2 kB
Grand total space consumed: 66 kB
bstnA(gbl)# ...
For a Range of Dates
You can set a start date and/or an end date for archive’s contents. To set a
range of dates in this way, use the start-date clause, the end-date clause, or
both. These go in place of the date clause shown above.
CLI Maintenance Guide
3 - 37
Chapter 3
Tracking Files on Your Back-End Storage
This syntax shows all archive contents from some earlier start date until
today:
show file‐history archive name contents start‐date date [namespace ns volume path] ...
where date is some day in the past. The end date is today, implicitly.
Use mm/dd/yyyy format.
This shows all archived snapshots from the first one up until a particular end
date:
show file‐history archive name contents end‐date {today | date} [namespace ns volume path] ...
where today | date is the last day in the query. Implicitly, the start date
is the date of the first snapshot in the archive. Use mm/dd/yyyy format
for a date.
This final option combines the two, so that you see all file-history snapshots
that were archived between two dates:
show file‐history archive name contents start‐date date end‐date date ...
For example, this command shows all of the path configurations since a
particular date in January. The command creates verbose output and sends it
to a report:
bstnA(gbl)# show file‐history archive fileRecordsMed contents start‐date 01/07/2009 report flRcrdsSinceJan
Generating report: flRcrdsSinceJan_20090121093046.rpt
bstnA(gbl)#
For a Time Period Leading Up to an End Date
You can also count back from an end date with the show file-history
archive command. To accomplish this, you specify some number of days,
weeks, months, and so on that lead up to the end date:
show file‐history archive name contents count {days|weeks|months|quarters|years} before {today | date} ...
where
count (1-100) is the number of days, weeks, or whatever you
choose with the next argument.
days|weeks|...|years indicates the time unit.
today | date is the last day in the query. Use mm/dd/yyyy format for
a date.
the remaining arguments, not shown above, are the ones described
earlier: namespace, volume, and report.
For example, the following command shows all snapshots sent to the
“fileRecordsMed” archive over the past 3 months:
bstnA(gbl)# show file‐history archive fileRecordsMed contents 3 months before today
Query Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive: fileRecordsMed
Start date: Mar 30 2010
End date: Jun 30 2010
3 - 38
Maintaining a File-History Archive: Listing Records
Namespace:
Volume:
Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
Archive Date/Time Namespace:Volume Snapshot Rule Config Metadata
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐
Jun 30 2010 01:06:00 medarcv:/lab_equipment labArchive 2.1 kB 32 kB
Jun 30 2010 01:11:00 medarcv:/rcrds rcrdsArchive 2.2 kB 64 kB
Summary:
Total space consumed by Volume Metadata: 96 kB
Total space consumed by Volume Configuration: 4.3 kB
Grand total space consumed: 100 kB...
Clearing Records from a File-History Archive
As time goes on, the number of file-history records (volume configurations,
and possibly metadata snapshots) on the file-history archive grows. You
may want to remove very-old records from the archive to conserve space.
You may also want to remove all the file-history records for a removed
service; recall Removing a Full Namespace Service, on page 10-49. Other
occasions may also arise where it is useful to remove file-history records
from the archive filer.
From priv-exec mode, use the clear file-history archive command to
remove volume configurations (and possibly volume metadata) from an
archive:
clear file‐history archive name [metadata‐only] [time‐frame] [namespace ns volume path]
where
name (1-64 characters) identifies the desired archive.
metadata-only (optional) limits the clearing operation to volume
metadata, and preserves all of the selected volume-configuration
data. Without the volume metadata, you can query the
front-end-service configurations from a given record (Showing
Historical Configurations, on page 3-19), but you cannot query the
locations of particular files or directories (Showing File History, on
page 3-25).
time-frame (optional) identifies specific file-history record(s) to
clear. If you omit this option, the command clears file-history
records from the fullest span of time. A specific time frame takes
several forms, discussed in the subsections below.
ns (optional, 1-30 characters) selects the records from a particular
ARX namespace.
vol-path (optional, 1-1024 characters) focuses on one ARX
volume.
CLI Maintenance Guide
3 - 39
Chapter 3
Tracking Files on Your Back-End Storage
The CLI prompts for confirmation before removing any file-history records
from the archive; enter yes to proceed.
For example, the following command sequence exits to priv-exec mode and
clears all file-history records from the “medarcv~/rcrds” volume. After this
command, no file-history queries for this volume are possible in the
“fileRecordsMed” archive:
bstnA(gbl)# end
bstnA# clear file‐history archive fileRecordsMed namespace medarcv volume /rcrds
WARNING: Confirming this command removes all archived metadata and volume configuration data dated
between '12/31/1969' and '01/22/2009' inclusive from archive 'fileRecordsMed'.
Proceed? [yes/no] yes
bstnA#
The subsections below explain the various time frames that you can specify
for this command. These are the same time-frame formats used for the show
file-history archive command described above.
For a Particular Day
The most straightforward time-frame is a single date, shown in this syntax:
clear file‐history archive name [metadata‐only] date {today | date} [namespace ns volume path]
where
today | date indicates that you want to clear the archive contents
from the given day. This clears any and all
configurations/snapshots that were archived today or on the date
you provide. Use mm/dd/yyyy format for a date.
The remaining options are explained above.
For example, the following command sequence exits to priv-exec mode and
clears the file-tracking records archived on a particular date in January. The
clear command only removes records from a particular volume,
“medarcv~/rcrds:”
bstnA(gbl)# end
bstnA# clear file‐history archive fileRecordsMed date 01/07/2009 namespace medarcv volume /rcrds
WARNING: Confirming this command removes all archived metadata and volume configuration data dated
between '01/07/2009' and '01/07/2009' inclusive from archive 'fileRecordsMed'.
Proceed? [yes/no] yes
bstnA#
For another example, this clears records for all volumes on the same date:
bstnA(gbl)# end
bstnA# clear file‐history archive fileRecordsMed date 01/07/2009
WARNING: Confirming this command removes all archived metadata and volume configuration data dated
between '01/07/2009' and '01/07/2009' inclusive from archive 'fileRecordsMed'.
Proceed? [yes/no] yes
bstnA#
3 - 40
Maintaining a File-History Archive: Listing Records
For a Range of Dates
You can set a start date and/or an end date for clearing archive records. To
set a range of dates in this way, use the start-date clause, the end-date
clause, or both. These go in place of the date clause shown above.
This clears records from the first one up until a particular end date:
clear file‐history archive name [metadata‐only] end‐date {today | date} ...
where today | date is the last day in the query. Implicitly, the start date
is the date of the first snapshot in the archive. Use mm/dd/yyyy format
for a date.
This clears archive records from some earlier start date until today:
clear file‐history archive name [metadata‐only] start‐date date [namespace ns volume path]
where date is some day in the past. The end date is today, implicitly.
Use mm/dd/yyyy format.
This final option combines the two, so that you clear file-history records that
were archived between two dates:
clear file‐history archive name [metadata‐only] start‐date date end‐date date ...
For example, this command sequence clears volume metadata from
file-history records up to a particular date in January:
bstnA(gbl)# end
bstnA# clear file‐history archive fileRecordsMed metadata‐only end‐date 01/07/2009
WARNING: Confirming this command removes all archived metadata dated
between '12/31/1969' and '01/07/2009' inclusive from archive 'fileRecordsMed'.
Proceed? [yes/no] yes
bstnA(gbl)#
For a Time Period Leading Up to an End Date
You can also count back from an end date with the clear file-history
archive command. To accomplish this, you specify some number of days,
weeks, months, and so on that lead up to the end date:
clear file‐history archive name [metadata‐only] count {days|weeks|months|quarters|years} before {today | date} ...
where
count (1-100) is the number of days, weeks, or whatever you
choose with the next argument.
days|weeks|...|years indicates the time unit.
today | date establishes the last day’s records to be cleared. Use
mm/dd/yyyy format for a date.
the remaining arguments, not shown above, are the ones described
earlier: namespace and volume.
For example, the following command sequence clears the file-history
records archived in “fileRecordsMed” over the 4 months leading up to
January 7:
CLI Maintenance Guide
3 - 41
Chapter 3
Tracking Files on Your Back-End Storage
bstnA(gbl)# end
bstnA# clear file‐history archive fileRecordsMed 4 months before 01/07/2009
WARNING: Confirming this command removes all archived metadata and volume configuration data dated
between '09/07/2008' and '01/07/2009' inclusive from archive 'fileRecordsMed'.
Proceed? [yes/no] yes
bstnA# ...
3 - 42
4
Restoring a Volume’s Files
• Overview
• Moving the Backup File(s) to the Staging Area
• Manually Restoring File(s)
• Automatically Restoring File(s)
Overview
Overview
This chapter applies to managed volumes, where policy-based migrations
complicate the backup and restore processes. Skip this chapter if your site
only supports direct volumes.
You can back up client files by working around a managed volume and
connecting directly to its back-end filers. Backups are read operations, so
they cannot create inconsistencies in a volume’s metadata. This can follow
the same workflow that was used before the introduction of the ARX. For
example, you might use NDMP on a data-protection device (called a backup
server in this manual) to keep file-server backups:
backup server
servers
backup
ARX
clients
Appendix 3, Tracking Files on Your Back-End Storage, explained how to
find back-end file locations at any given time. This chapter explains some
methods for restoring them to an ARX service.
CLI Maintenance Guide
4-3
Chapter 4
Restoring a Volume’s Files
Moving the Backup File(s) to the Staging Area
You can use the output from show file-history virtual-service or find to
retrieve files from your backup server. For example, consider the following
command which shows the location of the “a_adams.dat” file as of the last
series of backups (September 14 in this example):
bstnA# show file‐history virtual‐service ac1.medarch.org ARCHIVES date 09/14/2009 file a_adams.dat path /2005/planA
Date range
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Start date: Sep 14 2009
End date: Sep 14 2009
Archive: fileRecordsMed
Hosting Switch: bstnA (d9bdece8‐9866‐11d8‐91e3‐f48e42637d58)
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Archive Date/Time: Sep 14 2009 01:07:00
Global Server: ac1.medarch.org
WINS Name:
WINS Aliases:
Dynamic DNS Names: ac1, fs1, fs2, fs5
VIP: 192.168.25.15
Namespace: medarcv
Volume Path: /rcrds/2005/planA
File Server(s):
Shared Path: \\fs1\histories
Physical Path: d:\exports\histories\2005\planA
File Name: a_adams.dat
bstnA# ...
From this example, we found the following information about the file:
• as of September 14,
• the file was physically on the “fs1” filer, at
“d:\exports\histories\2005\planA\a_adams.dat.”
You can use the find command to locate the same file as of now. This shows
that the file migrated to the filer at “192.168.25.27” since September 14:
bstnA# find global‐server ac1.medarch.org cifs ARCHIVES path /2005/planA/a_adams.dat
Namespace: medarcv
Logical path: /rcrds/2005/planA/a_adams.dat
CIFS Physical location: //192.168.25.27/bulkstorage/2005/planA/a_adams.dat
bstnA# ...
Using the earlier date and filer path, you can recover the file from your
backup server. From the examples above, the file was on “fs1” on
September 14, when backups occurred. At the backup server, we recover the
4-4
Moving the Backup File(s) to the Staging Area
file from the September-14 backup of “fs1”. We suggest placing the
recovered file back onto the original filer (“fs1”), but outside any imported
directory. This side directory acts as a staging area for restored files.
Important
If the staging-area directory is inside any imported tree, this restore
operation causes an inconsistency between the filer state and the metadata
in a managed volume. We strongly advise that you choose a staging area
that is not imported by any managed volume.
backup server
servers
ARX
mgmt station
clients
CLI Maintenance Guide
4-5
Chapter 4
Restoring a Volume’s Files
Manually Restoring File(s)
A trouble ticket typically includes the file location from the client’s
perspective: in this example,
“\\ac1.medarch.org\ARCHIVES\2005\planA\a_adams.dat.” From your
management station, you can connect to the staging area through NFS or
CIFS and also connect to the ARX service. For example, you could map
your Y drive to “\\fs1\recoveryStage” on the filer and map your Z drive to
“\\ac1.medarch.org\ARCHIVES” on the ARX. With both connections
established, you can copy the file from the staging area into the front-end
service. The ARX immediately places the file onto the filer where it should
currently reside, based on your storage policies:
backup server
servers
(ARX sends to correct filer)
1 - copy
ARX
mgmt station
2 - paste
clients
4-6
Automatically Restoring File(s)
Automatically Restoring File(s)
A restore operation automatically copies a restored file from the staging
area to its managed volume, which then places the file into the share where
it currently resides:
backup server
servers
restore
ARX
clients
This operation creates a new “restore” directory under the directory where
the original file(s) should reside; from there, a client can compare the
restored file(s) to the original(s) and choose between the two versions.
You can repeat the restore operation for later restores from the same staging
area. This operation automatically distributes all restored files to their
respective back-end shares.
Adding an External Filer for the Staging Area (optional)
Before you use the restore data command (described below), you need to
identify the file server with the staging-area directory. This is the source for
the ARX-restore operation. In most cases, the staging area is on the same
filer where the file originally resided, in a directory outside of any imported
share. In this case, the external-filer configuration already exists to support
the imported share(s), and you can skip to the next section.
For cases where the staging area is on a filer that is currently unused by the
ARX, configure it as an external filer. (For detailed instructions on this,
refer to Appendix 6, Adding an External Filer in the ARX® CLI
Storage-Management Guide.)
Note
An external-filer configuration, as opposed to a simple IP address, is
required to accommodate multi-homed filers.
CLI Maintenance Guide
4-7
Chapter 4
Restoring a Volume’s Files
For example, the following command sequence sets up a file server at
192.168.25.51:
bstnA(gbl)# external‐filer nasE1
bstnA(gbl‐filer[nasE1])# ip address 192.168.25.51
bstnA(gbl‐filer[nasE1])# ...
Restoring Client Data
The restore data command invokes the restore operation:
restore data namespace volume vol path dest‐path filer src‐filer {nfs export | cifs share}+ source‐path src‐path [recurse] [remove‐source]
where
namespace volume vol path dest-path identifies the file or
directory to restore:
•
namespace is 1-30 characters. Use the namespace from the
show file-history virtual-service or find output, shown
earlier.
•
vol is 1-1024 characters. Type ? for a list of volumes in the
above namespace, and choose the volume behind the client’s
front-end share. If you cannot find the complete path you need
(such as “/claims/stats”), choose the volume that is the root of
your path (“/claims”).
•
dest-path is also 1-1024 characters. This could be the
remainder of the path you started with the vol, above (for
example, “/stats”). The restore process creates a “/restore”
directory below this path, and places the restored file(s) in
there.
filer src-filer {nfs export | cifs share}+ source-path src-path
points to the filer with the staging area and the backup file(s):
•
src-filer (1-64 characters) is the external-filer name for the
filer with the staging area,
•
nfs export (1-1024 characters) identifies the NFS export, and
•
cifs share (1-1024 characters) identifies the CIFS share. For a
multi-protocol share, enter both paths: nfs export cifs share.
•
src-path (1-1024 characters) is the path to the backup file(s).
This is the staging-area directory.
You can enter the optional recurse and remove flags in any order:
4-8
•
recurse (optional) causes the restore operation to descend into
subdirectories.
•
remove-source (optional) activates a clean-up routine after the
restore is finished; the restore operation removes the backup
files after confirming a successful restore to the volume.
Automatically Restoring File(s)
Every restore operation produces a report as it runs. The CLI shows the
report name after you invoke the command. Use show reports for a full list
of restore reports, and use show, tail, or grep to view one report. The report
shows the progress of the operation.
For example, the following command sequence restores a full directory,
“/claims/stats” in the “insur” namespace, then shows the restore report. The
source of the restore is a multi-protocol share on external filer named
“nasE1:”
bstnA(gbl)# end
bstnA# restore data insur volume /claims path stats filer nasE1 nfs /root_vdm_4/backups cifs BACKUPS source‐path /stats recurse
Scheduling restore operation on switch bstnA, report name: restore.7._claims.rpt
bstnA# ...
bstnA# show reports restore.7._claims.rpt
**** Restore Data Report: Started at Wed Feb 24 02:14:07 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: insur
**** Volume: /claims
**** Path: /stats/restore
**** Source Filer: 192.168.25.51
**** Source NFS Export: /root_vdm_4/backups
**** Source CIFS Share: BACKUPS
**** Source Path: /stats
**** Options: recurse
**** Legend:
**** OK = Object transferred without error.
**** SK = Skipped object due to naming problems.
**** FL = Encountered error during object transfer.
**** SY = Error re‐syncing directory attributes after data restore.
**** DS = Error deleting source file or directory.
**** NR = Did not recurse due to problematic directory contents.
**** SA = Failed due to strict attribute consistency requirement.
**** FE = File entry.
**** DE = Directory entry.
**** LE = Hard link.
**** SE = Symbolic link.
**** Multi‐Protocol Issues:
**** CC = Case‐blind collision.
**** NE = Entry found with NFS that was not found with CIFS.
**** CE = Entry found with CIFS that was not found with NFS.
**** SL = Symbolic link found with NFS that was not found with CIFS.
**** IC = CIFS invalid characters found in NFS name.
**** NM = CIFS name has characters that are not mappable to the NFS encoding.
**** FN = A portion of the name contains a filer‐generated pattern.
**** NC = Unable to copy CIFS data due to a filer‐generated name.
Entry Type Size Object
‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ CC] [ ] /stats/piechart.ppt
[ CC] [ ] /stats/PieChart.ppt
[ IC] [ ] /stats/on_the_job:2004.cnv
[ IC] [ ] /stats/on_the_job:2003.cnv
[ IC] [ ] /stats/in_home:2005
[OK FE NC] [ 3,575,056] /stats/PieChart.ppt
CLI Maintenance Guide
4-9
Chapter 4
Restoring a Volume’s Files
[OK FE ] [ 6,562] /stats/acmeIns.txt
[OK FE NC] [ 722,589] /stats/piechart.ppt
[OK FE NC] [ 1,679] /stats/on_the_job:2003.cnv
[OK FE NC] [ 9,509] /stats/on_the_job:2004.cnv
[ IC] [ ] /stats/in_home:2005/age:11‐21yrs.csv
[ IC] [ ] /stats/in_home:2005/age:>21yrs.csv
[ IC] [ ] /stats/in_home:2005/age:<10yrs.csv
[ IC] [ ] /stats/in_home:2005/age:>21yrs.csv
[ IC] [ ] /stats/in_home:2005/age:<10yrs.csv
[ IC] [ ] /stats/in_home:2005/age:11‐21yrs.csv
[OK DE NC] [ ] /stats/in_home:2005
[OK FE NC] [ 335,872] /stats/in_home:2005/age:11‐21yrs.csv
[OK FE NC] [ 267,264] /stats/in_home:2005/age:>21yrs.csv
[OK FE NC] [ 59,712] /stats/in_home:2005/age:<10yrs.csv
[OK FE ] [ 2,432] /stats/cleanBU.csh
[OK FE ] [ 4,545] /stats/update.csh
[OK FE ] [ 1,423] /stats/index.html
[OK FE ] [ 1,985] /stats/makeCd.pl
[OK FE ] [ 4,110] /stats/carrierCrossCheck.html
[OK FE ] [ 0] /stats/21yrs.csv
[OK DE ] [ ] /stats/otj_latest
[OK FE ] [ 3,438] /stats/otj_latest/feb.xls
[OK FE ] [ 71,462] /stats/otj_latest/april.xls
[OK FE ] [ 17,279] /stats/otj_latest/july.xls
[OK FE ] [ 17,629] /stats/otj_latest/october.xls
[OK FE ] [ 3,321] /stats/otj_latest/jan.xls
**** Total Found Items: 21
**** Total Transferred Items: 21
**** Total Failures: 0
**** Total Bytes Restored: 5,105,867
**** Total processed: 21
**** Elapsed time: 00:00:02
**** Restore Data Report: DONE at Wed Feb 24 02:14:09 2010 ****
bstnA# ...
Running the Restore from a Remote Host
From any remote host that supports the Secure SHell (SSH) protocol, you
can run the restore data command and see the report. Use the following
syntax with ssh:
ssh admin‐user@mip “restore data...”
where
admin-user is the username for a valid administrative account at
the ARX (use show users to list all of them, as shown in Listing All
Administrative Users, on page 2-14 of the ARX® CLI
Network-Management Guide),
mip is a management-IP address for the ARX (use show interface
mgmt to show the out-of-band management interface, or show
interface vlan to show all in-band management interfaces), and
restore data... is the full restore data command, described above.
Surround this with quotation marks (““).
4 - 10
Automatically Restoring File(s)
The output of the CLI command appears in the local shell. This also works
with all show commands.
For example, the following command sequence re-runs the above restore
data command from a remote machine, “mgmt17.”
juser@mgmt17:~$ ssh admin@10.1.1.7 “restore data insur volume /claims path stats filer nasE1 nfs /root_vdm_4/backups cifs BACKUPS source‐path /stats recurse”
Command>restore data insur volume /claims path stats filer nasE1 nfs /root_vdm_4/backups cifs BACKUPS source‐path /stats recurse
Scheduling restore operation on switch bstnA, report name: restore.9._claims.rpt
juser@mgmt17:~$ ssh admin@10.1.1.7 “show reports restore.9._claims.rpt”
Command>show reports restore.9._claims.rpt
**** Restore Data Report: Started at Wed Feb 25 10:52:11 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: insur
**** Volume: /claims
**** Path: /stats/restore
**** Source Filer: 192.168.25.51
**** Source NFS Export: /root_vdm_4/backups
**** Source CIFS Share: BACKUPS
**** Source Path: /stats
**** Options: recurse
**** Legend:
**** OK = Object transferred without error.
**** SK = Skipped object due to naming problems.
**** FL = Encountered error during object transfer.
**** SY = Error re‐syncing directory attributes after data restore.
**** DS = Error deleting source file or directory.
**** NR = Did not recurse due to problematic directory contents.
**** SA = Failed due to strict attribute consistency requirement.
**** FE = File entry.
**** DE = Directory entry.
**** LE = Hard link.
**** SE = Symbolic link.
**** Multi‐Protocol Issues:
**** CC = Case‐blind collision.
**** NE = Entry found with NFS that was not found with CIFS.
**** CE = Entry found with CIFS that was not found with NFS.
**** SL = Symbolic link found with NFS that was not found with CIFS.
**** IC = CIFS invalid characters found in NFS name.
**** NM = CIFS name has characters that are not mappable to the NFS encoding.
**** FN = A portion of the name contains a filer‐generated pattern.
**** NC = Unable to copy CIFS data due to a filer‐generated name.
Entry Type Size Object
‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ CC] [ ] /stats/piechart.ppt
[ CC] [ ] /stats/PieChart.ppt
[ IC] [ ] /stats/on_the_job:2004.cnv
[ IC] [ ] /stats/on_the_job:2003.cnv
[ IC] [ ] /stats/in_home:2005
[OK FE NC] [ 3,575,056] /stats/PieChart.ppt
[OK FE ] [ 6,562] /stats/acmeIns.txt
[OK FE NC] [ 722,589] /stats/piechart.ppt
[OK FE NC] [ 1,679] /stats/on_the_job:2003.cnv
CLI Maintenance Guide
4 - 11
Chapter 4
Restoring a Volume’s Files
[OK FE NC] [ 9,509] /stats/on_the_job:2004.cnv
[ IC] [ ] /stats/in_home:2005/age:11‐21yrs.csv
[ IC] [ ] /stats/in_home:2005/age:>21yrs.csv
[ IC] [ ] /stats/in_home:2005/age:<10yrs.csv
[ IC] [ ] /stats/in_home:2005/age:>21yrs.csv
[ IC] [ ] /stats/in_home:2005/age:<10yrs.csv
[ IC] [ ] /stats/in_home:2005/age:11‐21yrs.csv
[OK DE NC] [ ] /stats/in_home:2005
[OK FE NC] [ 335,872] /stats/in_home:2005/age:11‐21yrs.csv
[OK FE NC] [ 267,264] /stats/in_home:2005/age:>21yrs.csv
[OK FE NC] [ 59,712] /stats/in_home:2005/age:<10yrs.csv
[OK FE ] [ 2,432] /stats/cleanBU.csh
[OK FE ] [ 4,545] /stats/update.csh
[OK FE ] [ 1,423] /stats/index.html
[OK FE ] [ 1,985] /stats/makeCd.pl
[OK FE ] [ 4,110] /stats/carrierCrossCheck.html
[OK FE ] [ 0] /stats/21yrs.csv
**** Total Found Items: 15
**** Total Transferred Items: 15
**** Total Failures: 0
**** Total Bytes Restored: 4,992,738
**** Total processed: 15
**** Elapsed time: 00:00:02
**** Restore Data Report: DONE at Wed Feb 25 10:52:22 2010 ****
juser@mgmt17:~$ Showing all Restore Operations
A restore operation occurs in the background while you can run other CLI
commands or GUI functions. To see the high-level status of all restore
operations, use the show restore data command:
show restore data
For example, this shows that the current switch has had two successful
restores:
bstnA(gbl)# show restore data
Namespace: wwmed
Volume: /acct
Path: /
Options: recurse
Source Filer: das1 [192.168.25.19]
NFS Source: /exports/backups/acct
Status: Success
Report Name: restore.6._acct.rpt (bstnA)
Items Found: 225
Items Transferred: 225
Failures: 0
Total Bytes Restored: 11,163,668
Completed at: Mon Sep 14 01:29:11 2009
Namespace: insur
Volume: /claims
Path: /stats
Options: recurse
Source Filer: nasE1 [192.168.25.51]
NFS Source: /root_vdm_4/backups/stats
4 - 12
Automatically Restoring File(s)
CIFS Source: BACKUPS/stats
Status: Success
Report Name: restore.7._claims.rpt (bstnA)
Items Found: 21
Items Transferred: 21
Failures: 0
Total Bytes Restored: 5,105,867
Completed at: Mon Sep 14 01:28:01 2009
bstnA(gbl)# ...
Focusing on a Single Namespace, Volume, or Path
You can add some options to show a smaller set of restore operations:
show restore data [namespace [volume vol‐path [path path]]]
where
namespace (1-30 characters) selects a namespace,
vol-path (1-1024 characters) narrows the scope to a specific
volume, and.
path (1-1024 characters) narrows the scope further, to a specific
virtual path in the volume (for example, ‘/home/jrandom’). This is
relative to the vol-path.
For example, this command shows the restore operation performed on one
virtual directory, “insur~/claims/stats:”
bstnA(gbl)# show restore data insur volume /claims path /stats
Namespace: insur
Volume: /claims
Path: /stats
Options: recurse
Source Filer: nasE1 [192.168.25.51]
NFS Source: /root_vdm_4/backups/stats
CIFS Source: BACKUPS/stats
Status: Success
Report Name: restore.7._claims.rpt (bstnA)
Items Found: 21
Items Transferred: 21
Failures: 0
Total Bytes Restored: 5,105,867
Completed at: Mon Sep 14 01:28:01 2009
bstnA(gbl)# ...
Clearing Restore Operations from the Output
The show restore data command displays a running history of all restore
operations. The history goes back indefinitely, so the command can display
a very large number of records over time. You can clear all of these records
at once, or all records for a particular namespace, volume, or path. From
priv-exec mode, use the clear restore data command:
clear restore data [namespace [volume vol‐path [path path]]]
where
CLI Maintenance Guide
4 - 13
Chapter 4
Restoring a Volume’s Files
namespace (optional, 1-30 characters) identifies one namespace
with restore records. If this option is omitted, the command clears
all restore-operation records from the history.
vol-path (optional, 1-1024 characters) narrows the scope to one
volume, and
path (optional, 1-1024 characters) narrows the scope further to a
specific virtual path. This is relative to the vol-path.
Before clearing the records, a prompt requests confirmation; enter yes to
confirm. After you clear the records, they no longer appear in the show
restore data output.
This only affects completed restore operations. It does not affect any restore
operation that is in-process when you run the clear command.
For example, this command sequence shows all restore records, clears them,
then shows that there are none remaining:
bstnA(gbl)# show restore data
Namespace: wwmed
Volume: /acct
Path: /
...
Total Bytes Restored: 1,694,056
bstnA(gbl)# end
bstnA# clear restore data
Clear restore data records? [yes/no] yes
bstnA# show restore data
bstnA# ...
Canceling a Restore Operation
To cancel an in-progress restore operation, go to priv-exec mode and use the
cancel restore data command:
cancel restore data namespace volume vol‐path path path
where
namespace (1-30 characters) identifies the namespace,
vol-path (1-1024 characters) is the volume, and
path (1-1024 characters) is the specific virtual path that is being
restored. This is relative to the vol-path.
A prompt requests confirmation before the CLI cancels the restore; enter yes
to confirm that you want to cancel the operation.
For example, this command cancels a restore operation in the “wwmed”
namespace:
bstnA(gbl)# end
bstnA# cancel restore data wwmed volume /acct path /
Cancel specified restore data operations? [yes/no] yes
bstnA# ...
4 - 14
5
Backing Up the Running Configuration
• Overview
• Setting a Default FTP or SCP User
• Saving the Local Running Config
• Saving the Global Config
• Saving Both Configs
• Prepared for Disaster Recovery
• Restoring the Configuration
Overview
Overview
The switch configuration that you edit with the CLI is called the running
configuration, or running config. You can save the running config for the
next reboot, disaster recovery, or for exporting the configuration from one
switch to another.The running config is divided into two major components:
the local-running config for the current switch, and global config for
parameters that are shared by both switches in a redundant pair. This chapter
explains how to save both config types and restore them later.
Note
We recommend saving both the local-running config and the global config
after every configuration change. Both configs are vital for switch
replacement.
Note
In addition, to prepare for replacing a single switch in the unlikely event of
a failure, you should also save the following:
• Master key (extracted and wrapped). Save it to a remote host along with
the configs.
• Master key wrapping key password. Save it to a secure location.
Setting a Default FTP or SCP User
Before you begin backing up the configuration, you have the option to
simplify FTP uploads and/or SCP transfers later. The running config exists
in one or more local files, which you can copy to an external FTP or SCP
server. The default FTP username/password is
“anonymous/upgrade-hostname,” but you can enter a specific
username/password for each copy. There is no default for SCP transfers. To
avoid retyping FTP or SCP credentials each time, you can establish a default
username and password for each transfer protocol FTP.
From cfg mode, use ip ftp-user to set the FTP username:
ip ftp‐user username
where username is 1-32 characters.
From the same mode, you can also (or instead) use ip scp-user to set a
default username for SCP:
ip scp‐user username
where, as above, username is 1-32 characters.
The CLI then prompts twice for the password.
For example, the following command sequence sets up two default users
named “juser,” one for FTP and another for SCP:
bstnA(cfg)# ip ftp‐user juser
CLI Maintenance Guide
5-3
Chapter 5
Backing Up the Running Configuration
Password: jpasswd
Validate Password: jpasswd
bstnA(cfg)# ip scp‐user juser
Password: jpasswd
Validate Password: jpasswd
bstnA(cfg)# ...
5-4
Saving the Local Running Config
Saving the Local Running Config
The next step in saving the running configuration is to save the local running
config. The local running config applies only to the current switch: this
config includes network and chassis parameters. From priv-exec mode, use
the copy running-config command to save the local config as an executable
script.
copy running‐config scripts destination‐file
where
scripts is the destination directory, and
destination-file (1-1024 characters) is a name you choose for the
running-config file.
For example, the following command sequence exits to priv-exec mode,
copies the local running configuration to the scripts directory, then shows
the new script file:
bstnA(cfg)# exit
bstnA# copy running‐config scripts running
bstnA# show scripts
scripts
running Sep 19 05:03 5.7k
Saving the Config Off to an FTP Server
To save the running config off to a remote FTP server, use a URL in place
of the destination-file name. Follow the URL format below:
copy running‐config ftp://[username:password@]ftp‐site/file
where
username:password@ (optional) is an FTP username and
password (the default is the username/password set by the ip
ftp-user command, described above),
ftp-site identifies the FTP server with an IP address or FQDN (for
example, “172.16.88.3” or “ftp.myftpsite.com”), and
file is the chosen file name. Lead with an extra “/” if the path starts
at the root of the server machine; for example,
“aramis//var/cfg/running-config” specifies
“/var/config/running-config” on server aramis. Omit the leading
slash if the file is going to the home directory for username.
The CLI prints a message with the results of the copy operation.
CLI Maintenance Guide
5-5
Chapter 5
Backing Up the Running Configuration
For example, the following command exits from cfg mode to priv-exec
mode, then sends the running config to ftp.wwmed.com:
bstnA(cfg)# exit
bstnA# copy running‐config ftp://juser:jpasswd@ftp.wwmed.com/oct24lcl
% INFO: Copy config file to destination file 'oct24running' completed successfully.
bstnA# ...
Saving the Config Off to an SCP Server
For secure sites, you can upload with the Secure Copy (SCP) protocol. The
URL has a different syntax for SCP transfers:
copy running‐config scp://username@server:file [accept‐host‐key]
where
username@ (optional) is a valid username at the remote host (the
default is the username set by the ip scp-user command, described
above),
server identifies the SCP server with an IP address or FQDN (for
example, “172.16.100.18” or “deb1.mynet.com”), and
file is the chosen file name. Lead with a slash (scp-server:/file) if
the file path is absolute. Without the slash, the path is presumed to
start in the home directory for username.
accept-host-key (optional) tells the CLI to accept an unknown host
key if offered by the SCP server. The host key authenticates the
server; if the key is unknown, it is possible that an attacker has
taken the server’s hostname and/or IP address. Note that any SCP
server is “unknown” if the switch has not had an SCP exchange
with it since the switch’s last reboot.
The CLI prompts for the username’s password, unless you set up a default
with the ip scp-user command. If the prompt appears, enter a password that
is valid at the remote site.
Another prompt shows the results of the copy operation.
For example, the following command exits from gbl mode to priv-exec
mode, then sends the running config to rh1.wwmed.com. This goes to the
default user’s home directory, where the default user was set with the ip
scp-user command:
bstnA(gbl)# exit
bstnA# copy running‐config scp://rh1.wwmed.com:oct24running
% INFO: Copy config file to destination file 'oct24running' completed successfully.
bstnA# ...
5-6
Saving the Local Running Config
Placing the Config into an ARX Volume
You can also place the config file into an ARX volume. You can use the nfs
or cifs clause to send the config file to a given directory in a given volume:
copy running‐config {cifs|nfs} namespace volume dest‐path
where
cifs | nfs is a required choice. This is the network protocol used to
transfer the config file to the ARX volume.
namespace (1-30 characters) identifies the destination namespace.
volume (1-1024 characters) is the destination-volume name.
dest-path (1-1024 characters) is the intended path from the volume
root (above) to the config file. The directory you specify here must
exist on the volume.
The CLI prints a message with the results of the copy operation.
For example, the following command exits from gbl mode to priv-exec
mode, then sends the running-config to a directory in the “medarcv~/rcrds”
volume:
bstnA(cfg)# exit
bstnA# copy running‐config cifs medarcv /rcrds admin/oct24running
% INFO: Copy config file to destination file 'oct24running' completed successfully.
bstnA# ...
Sending the Config to an E-Mail Recipient
You can alternatively send the running-config file as an E-mail attachment.
Before you use E-mail, you must configure the Simple Mail Transfer
Protocol (SMTP) on the switch, starting with the smtp command in cfg
mode: see the chapter on E-mail and SMTP in the ARX® CLI Reference.
Use the following syntax to send the running-config file in an E-mail
message:
copy running‐config smtp://[e‐mail‐address/]file
where
e-mail-address (optional) identifies the recipient of the E-mail
message (for example, “myCoWorker@myco.com”). If you omit
this, it defaults to the E-mail recipient set with the cfg-smtp to
command. Use a slash (/) to separate this from the file name.
file is the chosen file name.
The CLI prints a message with the results of the copy operation.
For example, the following command sequence sets up SMTP, exits from
cfg mode to priv-exec mode, then mails the running-config file to
“juser@wwmed.com:”
bstnA(cfg)# smtp
CLI Maintenance Guide
5-7
Chapter 5
Backing Up the Running Configuration
bstnA(cfg‐smtp)# mail‐server email1.wwmed.com
bstnA(cfg‐smtp)# from admin@acopia.wwmed.com
bstnA(cfg‐smtp)# exit
bstnA(cfg)# exit
bstnA# copy running‐config smtp://juser@wwmed.com/oct24running
% INFO: Copy config file to destination file 'oct24running' completed successfully.
bstnA# ...
Showing the Local Config
You can send the current local config to the screen without saving it to a
file. Use the show running-config command to view all the CLI commands
required to re-create the local running-config.
show running‐config
For example:
bstnA> show running‐config
; ARX‐4000
; Version 6.01.000.14059 (Aug 12 2011 20:10:50) [nbuilds]
; Database version: 601000.106
; Generated running‐config Thu Aug 18 02:22:14 2011
; System UUID d9bdece8‐9866‐11d8‐91e3‐f48e42637d58
; ip private vlan internal 1010 metalog 1011 subnet 169.254.80.0 255.255.255.0
;
terminal character‐set unicode‐utf‐8
;================================= vlan ==================================
config
vlan 25
description "personnel dept."
members 2/5 to 2/5
exit
vlan 25
description rtTestVlan
members 2/6 to 2/6
exit
exit
;============================ config‐if‐vlan =============================
config
interface vlan 25
ip address 192.168.25.5 255.255.255.0
no shutdown
exit
interface vlan 25
ip address 10.46.11.253 255.255.0.0
no shutdown
exit
...
5-8
Saving the Global Config
Saving the Global Config
The next step in saving the running configuration is to save the
global-config parameters. The global config is the part of the configuration
that is shared among both ARXes in a redundant pair: this includes
namespace and policy parameters. From priv-exec mode, use the copy
global-config command to save the global config to an executable script file.
copy global‐config scripts destination‐file
where
scripts is the destination directory, and
destination-file (1-1024 characters) is a name you choose for the
global-config file.
For example, the following command sequence exits to priv-exec mode,
copies the global running configuration, then shows the new script file:
bstnA(cfg)# exit
bstnA# copy global‐config scripts global
bstnA# show scripts
scripts
global Sep 19 05:03 9.0k
running Sep 19 05:03 5.7k
Saving the Config Off to an FTP Server
To save the global config off to a remote FTP server, use an FTP URL as the
destination:
copy global‐config ftp://[username:password@]ftp‐site/file
where
username:password@ (optional) is an FTP username and
password (the default is the username/password set by the ip
ftp-user command),
ftp-site identifies the FTP server with an IP address or FQDN (for
example, “172.16.88.3” or “ftp.myftpsite.com”), and
file is the chosen file name. As with other FTP copies, use two
slashes (ftp-site//file) if the file path is absolute.
The CLI prints a message to show the results of the copy operation.
For example, the following command exits from gbl mode to priv-exec
mode, then sends the global config to /var/oct24gbl on ftp.wwmed.com:
bstnA(gbl)# exit
bstnA# copy global‐config ftp://juser:jpasswd@ftp.wwmed.com//var/oct24gbl
% INFO: Copy config file to destination file 'oct24gbl' completed successfully.
bstnA# ...
CLI Maintenance Guide
5-9
Chapter 5
Backing Up the Running Configuration
Saving the Config Off to an SCP Server
As with the running-config, you can also use the Secure Copy (SCP)
protocol to upload the global config:
copy global‐config scp://username@server:file [accept‐host‐key]
where
username@ (optional) is a valid username at the remote host (the
default is the username set by the ip scp-user command, described
earlier),
server identifies the SCP server with an IP address or FQDN (for
example, “172.16.100.12” or “host.mynet.com”), and
file is the chosen file name. Lead with a slash (scp-server:/file) if
the file path is absolute. Without the slash, the path is presumed to
start in the home directory for username.
accept-host-key (optional) tells the CLI to accept an unknown host
key if offered by the SCP server. The host key authenticates the
server; if the key is unknown, it is possible that an attacker has
taken the server’s hostname and/or IP address. Note that any SCP
server is “unknown” if the switch has not had an SCP exchange
with it since the switch’s last reboot.
The CLI prompts for the username’s password, unless you set up a default
with the ip scp-user command. If the prompt appears, enter a password that
is valid at the remote site.
The CLI then shows the results of the copy operation.
For example, the following command exits from gbl mode to priv-exec
mode, then sends the global config to the /var directory on rh1.wwmed.com.
This defaults to whatever username and password were set earlier with the
ip scp-user command:
bstnA(gbl)# exit
bstnA# copy global‐config scp://rh1.wwmed.com:/var/oct24gbl
% INFO: Copy config file to destination file 'oct24gbl' completed successfully.
bstnA# ...
Placing the Config into an ARX Volume
You can also place the config file into an ARX volume. You can use the nfs
or cifs clause to send the config file to a given directory in a given volume:
copy global‐config {cifs|nfs} namespace volume dest‐path
where
cifs | nfs is a required choice. This is the network protocol used to
transfer the config file to the ARX volume.
namespace (1-30 characters) identifies the destination namespace.
volume (1-1024 characters) is the destination-volume name.
5 - 10
Saving the Global Config
dest-path (1-1024 characters) is the intended path from the volume
root (above) to the config file. The directory you specify here must
exist on the volume.
The CLI prints a message with the results of the copy operation.
For example, the following command exits from gbl mode to priv-exec
mode, then sends the global-config to a directory in the “medarcv~/rcrds”
volume:
bstnA(cfg)# exit
bstnA# copy global‐config cifs medarcv /rcrds admin/oct24gbl
% INFO: Copy config file to destination file 'oct24gbl' completed successfully.
bstnA# ...
Sending the Config to an E-Mail Recipient
You can alternatively send the global-config file as an E-mail attachment, as
shown above for the running-config. Before you use E-mail, you must
configure the Simple Mail Transfer Protocol (SMTP) on the switch, starting
with the smtp command in cfg mode: see the chapter on E-mail and SMTP
in the ARX® CLI Reference.
Use the following syntax to send the global-config file in an E-mail
message:
copy global‐config smtp://[e‐mail‐address/]file
where
e-mail-address (optional) identifies the recipient of the E-mail
message (for example, “myCoWorker@myco.com”). If you omit
this, it defaults to the E-mail recipient set with the cfg-smtp to
command. Use a slash (/) to separate this from the file name.
file is the chosen file name.
For example, the following command sequence sets up SMTP (including a
destination E-mail address, “juser@wwmed.com”), exits from cfg mode to
priv-exec mode, then mails the global-config file:
bstnA(cfg)# smtp
bstnA(cfg‐smtp)# mail‐server email1.wwmed.com
bstnA(cfg‐smtp)# from admin@acopia.wwmed.com
bstnA(cfg‐smtp)# to juser@wwmed.com
bstnA(cfg‐smtp)# exit
bstnA(cfg)# exit
bstnA# copy global‐config smtp://oct24gbl
% INFO: Copy config file to destination file 'oct24gbl' completed successfully.
bstnA# ...
CLI Maintenance Guide
5 - 11
Chapter 5
Backing Up the Running Configuration
Showing the Global Config
You can send the current global config to the screen without saving it to a
file. Use the show global-config command to view all the CLI commands
required to re-create the global config.
show global‐config
The CLI commands appear in the proper order to be run as a CLI script.
Note
Secure information, such as passwords and private SSH keys, is shown in
encrypted form. Only the current ARX (or a replacement for it, in case of
failure) can decrypt these passwords or keys.
For example:
bstnA> show global‐config
; ARX‐4000
; Version 6.01.000.14059 (Aug 12 2011 20:10:50) [nbuilds]
; Database version: 601000.106
; Generated global‐config Thu Aug 18 02:22:15 2011
;
terminal character‐set unicode‐utf‐8
;================================ global =================================
global
kerberos health‐check threshold 3500
nfs tcp timeout 30
;================================= user ==================================
user adm1 encrypted‐password 54yL5vSNV3206ZSWtR6dsumZt0fsIY25EMsJZf79tVk=
exit
user adm12 encrypted‐password C8rtkfSNV3206ZSWtR6dsumZt0fsIY25awo/NP+RwgoJFnaX9NTD0A==
exit
user admin encrypted‐password 50bNTfSNV3206ZSWtR6dsumZt0fsIY25hfpcuPT8l2k=
exit
user newadmin encrypted‐password zYmQlvSNV3206ZSWtR6dsumZt0fsIY2559EofswcJQlCn8uRIue7MQ==
exit
;================================= group =================================
group Administrators
role backup‐operator
role crypto‐officer
role network‐engineer
role operator
role storage‐engineer
windows‐domain MEDARCH.ORG
exit
...
bstnA>
Focusing On Specific Configuration Sections
You can show an individual group of commands from the show
global-config output:
5 - 12
Saving the Global Config
show global‐config {filer | namespace | schedule | security | global‐server | nfs | cifs}
where
• filer shows the “external-filer” section of the report,
• namespace shows the “namespace” section,
• schedule shows all policy schedules,
• security shows all sections related to security (such as “group,”
“radius-server,” and “authentication”),
• global-server focuses on the “global-server” section,
• nfs shows the “nfs” section, and
• cifs shows the “cifs” section.
For example, the following command shows the security configuration:
bstnA> show global‐config security
;================================= group =================================
;============================= radius‐server =============================
;============================ nfs‐access‐list ============================
;============================= ntlm‐auth‐db ==============================
;=========================== ntlm‐auth‐server ============================
;============================== proxy‐user ===============================
;============================= win‐mgmt‐auth =============================
group admins
role storage‐engineer
user adm1
user adm12
exit
group crypto‐officer
user admin
user newadmin
exit
group operator
user admin
user newadmin
user adm1
user adm12
exit
radius‐server 192.168.25.201
exit
radius‐server 192.168.25.207
auth‐port 5555
retries 4
timeout 10
exit
nfs‐access‐list eastcoast
anonymous‐gid 100
anonymous‐uid 100
description "allowable subnets in MA, NY, & DC"
nis domain wwmed.com
permit 172.16.100.0 255.255.255.0 read‐write root squash
permit 172.16.204.0 255.255.255.0 read‐only root allow
permit 172.16.0.0 255.255.0.0 read‐write root squash
CLI Maintenance Guide
5 - 13
Chapter 5
Backing Up the Running Configuration
permit netgroup surgeons read‐write root allow
permit netgroup medtechs read‐only root squash
deny 192.168.77.0 255.255.255.0
deny 192.168.202.0 255.255.255.0
permit 192.168.98.0 255.255.255.0 read‐write root allow
permit 192.168.0.0 255.255.0.0 read‐write root squash
exit
nfs‐access‐list westcoast
permit 172.209.3.0 255.255.255.0 read‐write root squash
permit 172.214.1.0 255.255.255.0 read‐write root squash
exit
ntlm‐auth‐db ntlmMap2
user lab encrypted‐password V4K/jx9iwZifO974V0iS8Ok7sDMUUbqhqBMhDuKWYxzjxAKG
exit
ntlm‐auth‐server dc1
encrypted‐password V4K/jx9iwZifO974V0iS8Ok7sDOIJkPBi71fuA==
ip address 192.168.25.109
windows‐domain MEDARCH.ORG pre‐win2k‐name NTNET
exit
ntlm‐auth‐server dc2
encrypted‐password V4K/jx9iwZifO974V0iS8Ok7sDOIJkPBi71fuA==
ip address 192.168.25.102
windows‐domain MEDARCH.ORG pre‐win2k‐name NTNET
exit
proxy‐user acoProxy1
description "jq's admin account"
user jqprivate encrypted‐password cvg641eCv48fYsGYnzve+FdIkvDpO7AzXojEXNAVoQPImlaxoo5n+Q==
windows‐domain WWMEDNET.COM pre‐win2k‐name WWMEDNET
exit
proxy‐user acoProxy3
user jqtester encrypted‐password kKeW+leCv48fYsGYnzve+FdIkvDpO7AzhwGkkWvNEGsBww9YLuYfCw==
windows‐domain FDTESTNET.COM pre‐win2k‐name BOSTONCIFS
exit
proxy‐user cifs_admin
user Administrator encrypted‐password ePQN2FeCv48fYsGYnzve+FdIkvDpO7AziCZDwYu9X7g=
windows‐domain MEDARCH.ORG pre‐win2k‐name MEDARCH
exit
proxy‐user nas_admin
user root encrypted‐password ePQN2FeCv48fYsGYnzve+FdIkvDpO7AziCZDwYu9X7g=
exit
proxy‐user ny_admin
user jqpublic encrypted‐password Vz86CleCv48fYsGYnzve+FdIkvDpO7AzQA1GJKVKGF4=
windows‐domain NY.COM pre‐win2k‐name NY
exit
proxy‐user acoProxy2
description "user with backup and admin creds on our servers"
user jqpublic encrypted‐password Vz86CleCv48fYsGYnzve+FdIkvDpO7AzQA1GJKVKGF4=
windows‐domain MEDARCH.ORG pre‐win2k‐name MEDARCH
exit
windows‐mgmt‐auth fullAccess
permit all any
5 - 14
Saving the Global Config
user juser windows‐domain MEDARCH.ORG
user jquser windows‐domain MEDARCH.ORG
exit
windows‐mgmt‐auth readOnly
permit session monitor
permit share monitor
permit snapshot monitor
user mhoward_md windows‐domain MEDARCH.ORG
user zmarx_cpa windows‐domain MEDARCH.ORG
user lfine_md windows‐domain MEDARCH.ORG
user choward_md windows‐domain MEDARCH.ORG
exit
windows‐mgmt‐auth snapViewers
permit snapshot monitor
user juser windows‐domain MEDARCH.ORG
user jquser windows‐domain MEDARCH.ORG
exit
bstnA>
Focusing On Named Configurations
You can show an individual namespace, volume, or front-end service by
specifying the name at the end of the command:
show global‐config namespace name [volume]
where
name (1-30 characters) identifies the namespace,
or
show global‐config {nfs | cifs} name
where name (1-255 characters) is the fully-qualified domain name
(FQDN) for the front-end service.
For example, the following command shows the configuration for the
“medarcv” namespace:
bstnA> show global‐config namespace medarcv
;=============================== namespace ===============================
namespace medarcv
protocol cifs
cifs authentication kerberos
cifs authentication ntlm
cifs authentication ntlmv2
ntlm‐auth‐server dc1
ntlm‐auth‐server dc2
proxy‐user acoProxy2
windows‐mgmt‐auth readOnly
windows‐mgmt‐auth fullAccess
windows‐mgmt‐auth snapViewers
sam‐reference fs2
volume /lab_equipment
cifs access‐based‐enum auto‐enable
cifs notify‐change‐mode ignore‐subtree‐flag
modify
reimport‐modify
reserve files 4000000
CLI Maintenance Guide
5 - 15
Chapter 5
Backing Up the Running Configuration
snapshot directory display all‐exports
snapshot privileged‐access
snapshot vss‐mode none
auto sync files
metadata share nas1 nfs3 /vol/vol1/meta6
no compressed‐files
named‐streams
persistent‐acls
no sparse‐files
unicode‐on‐disk
share backlots
import sync‐attributes
policy freespace percent 3 resume‐migrate 5
filer fs2 cifs backlot_records
enable
exit
share equip
import priority 1
import skip‐managed‐check
policy freespace percent 3 resume‐migrate 5
filer nas10 cifs equipment
enable
exit
share leased
import priority 1
import sync‐attributes
policy freespace percent 3 resume‐migrate 5
filer nas10 cifs for_lease
enable
exit
share scanners
cifs access‐based‐enum exclude
import sync‐attributes
policy freespace percent 3 resume‐migrate 5
filer fs5 cifs xraysScanners
enable
exit
share‐farm tier1
share equip
share leased
balance capacity
auto‐migrate
enable
exit
share‐farm tier2
share backlots
share scanners
balance capacity
enable
exit
snapshot rule hourlySnap
schedule hourly
report snap_hourly
enable
exit
5 - 16
Saving the Global Config
snapshot rule dailySnap
schedule daily4am
report snap_daily
retain 5
enable
exit
snapshot rule labArchive
schedule daily4am
report FA_lab error‐only
archive fileRecordsMed
no contents user‐data
contents volume‐config metadata
enable
exit
place‐rule busy2tier1
schedule daily4am
report leTier1 verbose delete‐empty
inline report hourly leTier1 verbose
from fileset modThisMonth
target share‐farm tier1
enable
exit
place‐rule nonbusy2tier2
schedule daily4am
report leTier2 verbose delete‐empty
from fileset modEarlier
target share‐farm tier2
no inline notify
enable
exit
place‐rule masterDirs2Tier1
from fileset allDirs match directories promote‐directories
target share‐farm tier1
enable
exit
volume‐group 2
enable
exit
volume /rcrds
filer‐subshares replicate
modify
reimport‐modify
reserve files 4000000
...
exit
bstnA>
CLI Maintenance Guide
5 - 17
Chapter 5
Backing Up the Running Configuration
Saving Both Configs
The startup config is a combination of the running config and the global
config. You can save the startup config as a single file. From priv-exec
mode, use the copy startup-config command to save the startup config to an
executable script file.
copy startup‐config scripts destination‐file
where
scripts is the destination directory, and
destination-file (1-1024 characters) is a name you choose for the
startup-config file.
For example, the following command sequence exits to priv-exec mode,
copies the startup configuration, then shows the new script file:
bstnA(cfg)# exit
bstnA# copy startup‐config scripts start_conf
bstnA# show scripts
scripts
global Sep 19 05:03 9.0k
running Sep 19 05:03 5.7k
start_conf Sep 19 05:03 14k
Saving the Config Off to an FTP Server
Use a URL in the copy startup-config command to save the startup config to
an FTP site:
copy startup‐config ftp://[username:password@]ftp‐site/file
where
username:password@ (optional) is an FTP username and
password (the default is the username/password set by the ip
ftp-user command),
ftp-site identifies the FTP server with an IP address or FQDN (for
example, “172.16.88.3” or “ftp.myftpsite.com”), and
file is the chosen file name. As with other FTP copies, use two
slashes (ftp-site//file) if the file path is absolute.
The CLI prints a message with the results of the copy operation.
For example, the following command exits from gbl mode to priv-exec
mode, then sends the startup config to ftp.wwmed.com:
bstnA(gbl)# exit
bstnA# copy startup‐config ftp://juser:jpasswd@ftp.wwmed.com/feb6startup
% INFO: Copy config file to destination file 'feb6startup' completed successfully.
bstnA# ...
5 - 18
Saving Both Configs
Saving the Config Off to an SCP Server
Use an SCP-based URL to upload with the Secure Copy (SCP) protocol:
copy startup‐config scp://username@server:file [accept‐host‐key]
where the options were defined for uploading the running-config (recall
Saving the Config Off to an SCP Server, on page 5-6).
The CLI prompts for the username’s password if there is no ip scp-user
defined. If the password prompt appears, enter a password that is valid at the
remote site. Then a message shows the results of the copy operation.
For example, the following command exits from gbl mode to priv-exec
mode, then sends the startup config to the /var directory on
rh1.wwmed.com:
bstnA(gbl)# exit
bstnA# copy startup‐config scp://juser@rh1.wwmed.com:/var/feb6startup
Password: jpasswd
% INFO: Copy config file to destination file 'feb6startup' completed successfully.
bstnA# ...
Placing the Config into an ARX Volume
You can also place the config file into an ARX volume. You can use the nfs
or cifs clause to send the config file to a given directory in a given volume:
copy startup‐config {cifs|nfs} namespace volume dest‐path
where
cifs | nfs is a required choice. This is the network protocol used to
transfer the config file to the ARX volume.
namespace (1-30 characters) identifies the destination namespace.
volume (1-1024 characters) is the destination-volume name.
dest-path (1-1024 characters) is the intended path from the volume
root (above) to the config file. The directory you specify here must
exist on the volume.
The CLI prints a message with the results of the copy operation.
For example, the following command exits from gbl mode to priv-exec
mode, then sends the startup-config file to a directory in the
“medarcv~/rcrds” volume:
bstnA(cfg)# exit
bstnA# copy startup‐config cifs medarcv /rcrds admin/feb6startup
% INFO: Copy config file to destination file 'feb6startup' completed successfully.
bstnA# ...
CLI Maintenance Guide
5 - 19
Chapter 5
Backing Up the Running Configuration
Sending the Config to an E-Mail Recipient
You can alternatively send the startup-config file as an E-mail attachment,
as shown above for the global-config and running-config. Before you use
E-mail, you must configure the Simple Mail Transfer Protocol (SMTP) on
the switch, starting with the smtp command in cfg mode: see the chapter on
E-mail and SMTP in the ARX® CLI Reference.
Use the following syntax to send the startup-config file in an E-mail
message:
copy startup‐config smtp://[e‐mail‐address/]file
where the options were defined for mailing the running-config (recall
Sending the Config to an E-Mail Recipient, on page 5-7).
For example, the following command sequence sets up SMTP (including a
destination E-mail address, “juser@wwmed.com”), exits from cfg mode to
priv-exec mode, then mails the startup-config file:
bstnA(cfg)# smtp
bstnA(cfg‐smtp)# mail‐server email1.wwmed.com
bstnA(cfg‐smtp)# from admin@acopia.wwmed.com
bstnA(cfg‐smtp)# to juser@wwmed.com
bstnA(cfg‐smtp)# exit
bstnA(cfg)# exit
bstnA# copy startup‐config smtp://feb6startup
% INFO: Copy config file to destination file 'feb6startup' completed successfully.
bstnA# ...
5 - 20
Prepared for Disaster Recovery
Prepared for Disaster Recovery
Once you have saved both the local and global running-configs (or the
single startup-config), the ARX is prepared for disaster-recovery.
Note
In addition, to prepare for replacing a single switch in the unlikely event of
a failure, you should also save the following:
• Master key (extracted and wrapped). Save it to a remote host along with
the configs.
• Master key wrapping key password. Save it to a secure location.
Restoring the Configuration
The first step to restoring the running config is to place the running-config
script(s) onto the chassis. If the scripts are already on the switch (for
example, if you saved the config(s) to the current chassis), you can skip this
section. If the scripts are on an FTP server, enter priv-exec mode and use
copy ftp to retrieve them:
copy ftp://[username:password@]ftp‐site/file scripts destination
where
username:password@ (optional) is an FTP username and
password (the default is the username/password set by the ip
ftp-user command),
ftp-site identifies the FTP server with an IP address or FQDN (for
example, “172.16.88.3” or “ftp.myftpsite.com”),
file is the script name at the server (lead with an extra “/” if the path
is absolute),
scripts specifies the directory for the destination file, and
destination is the script name at the chassis.
For example, the following command sequence copies the startup config
from ftp.wwmed.com:
bstnA> enable
bstnA# copy ftp://juser:jpasswd@ftp.wwmed.com/feb6startup scripts start_conf
% INFO: The copy command completed successfully.
bstnA# ...
Erasing the Current Configuration
You must remove the active “startup-config” file and reboot the switch
before you restore the running-config or startup-config. For example:
CLI Maintenance Guide
5 - 21
Chapter 5
Backing Up the Running Configuration
bstnA> enable
bstnA# delete startup‐config
Delete file 'startup‐config' in directory 'configs'? [yes/no] yes
bstnA# reload
Reload the entire chassis? [yes/no] yes
Broadcast message (Fri Feb 6 15:06:47 2004):
The system is going down for reboot NOW!
...
Wait for the machine to reboot, then log back in through the serial
CONSOLE port. (With the configuration erased, the MGMT port and all
inband (VLAN) management interfaces are unavailable.) For example:
User Access Authentication
SWITCH login: admin
Password: password
System authenticating at device scope.
Restoring the Local and Global Configs
From priv-exec mode, use the run command to run each running-config
script:
run scripts script‐name
where script-name (1-1024 characters) identifies the running-config
script. Use show scripts for a list of available scripts.
Important
In a redundant pair, the global config is shared by both switches. If you
restore the global config (either alone or as part of the startup config), you
overwrite all global parameters for both switches in the pair. We
recommend restoring the running-config first, rejoining the redundant pair,
then restoring the global config, as outlined in the next section.
The CLI commands run on the command line until the configuration is
finished.
For example, the following command sequence enters priv-exec mode,
shows the saved scripts, and runs the “start_conf” script (which contains
both the running and global configs):
SWITCH> enable
SWITCH# show scripts
scripts global Mar 16 01:59 6.5k
running Mar 16 01:59 3.0k
start_conf Mar 16 01:59 9.6k
SWITCH# run scripts start_conf
SWITCH# config
SWITCH(cfg)# hostname bstnA
5 - 22
Restoring the Configuration
bstnA(cfg)# ...
bstnA(gbl)# exit
bstnA# ...
Restoring Configs to a Redundant Pair
We recommend a two-phased approach for restoring configs to a redundant
pair: restore the running-config to each switch, then restore the
global-config on either switch. This synchronizes the pair before starting
any namespace imports. Other orders are possible, but this is considered best
practice.
Important
Do not restore the same running-config to both peers. The running-config
includes the switch’s private subnet, which must be unique to both peers. In
fact, the private subnet must be unique in the switch’s entire RON; see
Resolving Conflicting Subnets, on page 6-13 of the ARX® CLI
Network-Management Guide.
For instructions on joining a redundant pair, refer to Enabling Redundancy,
on page 7-19 of the ARX® CLI Network-Management Guide.
Restoring the Running Configuration
For example, the following command sequence updates the running-config
on both switches:
Peer A
SWITCH# run scripts running
SWITCH# config
SWITCH(cfg)# hostname prtlndA prtlndA(cfg)# ...
prtlndA(cfg)# exit
prtlndA# ...
Peer B
SWITCH# run scripts running‐B
SWITCH# config
SWITCH(cfg)# hostname prtlndB prtlndB(cfg)# ...
prtlndB(cfg)# exit
prtlndB# ...
Restoring the Global Configuration
For example, the following command sequence updates one switch with the
global-config:
Peer A
Wait for the peers to join. Use the show redundancy command: when both
peers and the quorum disk are “Up,” the pair is complete.
prtlndA(cfg‐redundancy)# show redundancy
CLI Maintenance Guide
5 - 23
Chapter 5
Backing Up the Running Configuration
Transitions
Node Switch/Quorum Disk Status Role Total Last (UTC)
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
*1 prtlndA Up Active Never ‐
2 prtlndB Up Backup 1 05:33:19 09/14/2009
QD 192.168.74.83 Up Quorum 1 05:33:07 09/14/2009
prtlndA(cfg‐redundancy)# ...
Exit to priv-exec mode and restore the global config:
prtlndA(cfg‐redundancy)# end
prtlndA# run scripts global
prtlndA# global
...
prtlndA(gbl)# exit
prtlndA# ...
Consideration For Restoring to an ARX-2500 Pair
There is a special consideration you must take into account when restoring a
configuration to an ARX-2500 pair, if the configuration changes the setting
of the resource-profile command.
After executing the resource-profile command on both devices in the pair,
you must execute the dual-reboot command to reboot both devices at once.
This is true also if you replay a running-config script with the
resource-profile legacy setting. (One method of replaying a
running-config is to save the file on the ARX-2500 and use the run
command.) After replaying the config script, you must reload the
ARX-2500 for resource-profile legacy to take effect.
Restoring to One Peer
If you are only restoring the config on one switch, run its running-config
script to set up networking and rejoin the switch with its waiting peer. The
switch downloads the global config when it joins the redundant pair. If you
want to replace the global-config too, run the global-config script on the
peer (Senior) switch after the pair has joined.
For example, the following sequence restores the running-config and rejoins
its peer. It does not restore the global config:
SWITCH# run scripts running‐B
SWITCH# config
SWITCH(cfg)# hostname prtlndB
prtlndB(cfg)# ...
prtlndB(cfg)# exit
prtlndB# ...
5 - 24
6
Upgrading Software
• Overview
• Before You Begin
• Saving the Configuration
• Checking the Health of the Switch
• Clearing Space for a New Release File
• Changing the Software Release
• Checking for New Firmware
• Sanity Check
• Upgrading a Redundant Pair
• Downgrading a Redundant Pair
Overview
Overview
ARX software is distributed in release files, typically named with a .rel
extension (for example, “initial.rel” or “arx-0.5.0_dev.rel”). To upgrade
software on the ARX, you must
1. clear space for a new release file (if necessary),
2. copy a new release file to the switch,
3. arm the switch with the release file, and
4. reboot the ARX.
This chapter describes this process in detail, then describes the process for
upgrading software in a redundant pair of switches. The process for
downgrading the software in a redundant pair is described as well, in the
event that such action must be taken.
Downgrades
Downgrading is the process of changing to an older software release, where
the release number is lower. The procedure for downgrading is similar to the
procedure for upgrading, except that it deletes the configuration; therefore,
you must take great care to preserve the configuration and edit it for the
lower release before you begin. At the end of the downgrade, you must
restore the configuration.
Important
Downgrades are not recommended. Consult with F5 Support before
performing a downgrade.
In case a downgrade is necessary, there are instructions that apply to
downgrades in this chapter. At the end of the chapter is a complete
procedure for downgrading a redundant pair of ARX devices. Most of the
chapter focuses on the upgrade scenario.
CLI Maintenance Guide
6-3
Chapter 6
Upgrading Software
Before You Begin
Performance Considerations For ARX-1500 and ARX-2500
The ARX-1500 and ARX-2500 store their metalog data on their internal
disks, along with logs, software-release files, and other management data.
Managed volumes write their metalog data as clients change the volume
state; the metalog is used to restore the volume configuration in the event of
a failure. The metalog is also copied to the redundant peer. The speed of
many volume operations depends on fast metalog writes.
Some other system operations create a large number of writes to the internal
disk, potentially slowing metalog writes. This can slow volume
performance, even if it occurs on the backup peer. For example, the process
of upgrading the software release is extremely disk intensive, and may cause
a noticeable performance degradation. During an upgrade, you use
• the copy command to copy a full release file to the disk, and
• the boot system command to unpack the release file on the disk.
You should perform such disk-intensive operations during off-peak hours on
the ARX-1500 and ARX-2500. This is true whether you run the operations
on the active peer or the backup.
Coordinating Upgrades Between Shadow-Volume Sites
Software upgrades may require more planning for multiple ARX sites. You
can configure a shadow-copy rule to copy data from a managed volume on
one ARX to a shadow volume on another ARX; for details, see Chapter 16,
Shadowing a Volume in the ARX® CLI Storage-Management Guide. To
upgrade both sites, we recommend pausing all policy operations at the
source volume (see Pausing All Rules in a Volume, on page 14-49 of the
same manual), upgrading software at the target site, and then upgrading
software at the source site.
If the sites have redundant-ARX pairs, upgrade both peers at the target site
(as described later in the chapter) before upgrading both peers at the source
site.
6-4
Saving the Configuration
Saving the Configuration
Back up your current configuration before initiating an upgrade or
downgrade procedure. The configuration is at risk, especially in a
downgrade; this makes it possible to reload the configuration later. Save the
network-configuration parameters (running-config) in one file and the
storage-configuration parameters (global-config) in another file. Use the
copy running-config command to back up the running-config, as described in
Saving the Local Running Config, on page 5-5. The copy global-config
command saves the global-config, as described in Saving the Global Config,
on page 5-9.
For example, this saves both config files to an external FTP server:
bstnA(cfg)# exit
bstnA# copy running‐config ftp://juser:jpasswd@ftp.wwmed.com/net_config
% INFO: Copy config file to destination file 'net_config' completed successfully.
bstnA# copy global‐config ftp://juser:jpasswd@ftp.wwmed.com/storage_config
% INFO: Copy config file to destination file 'storage_config' completed successfully.
bstnA# ...
Other Important Configuration Parameters
Record these configuration parameters, too. They are not part of the above
config files, but they are crucial to restoring an ARX to service:
• the password for the administrative account (named “admin” by default)
and
• the encrypted master key.
You can use the show master-key command to display the master key’s
encrypted value. For example:
bstnA# show master‐key
System Password: %uper$ecretpw
Wrapping Password: an0ther$ecretpw
Validate Wrapping Password: an0ther$ecretpw
Encrypted master key:
2oftVCwAAAAgAAAApwazSRFd2ww/H1pi7R7JMDZ9SoIg4WGA/XsZP+HcXjsIAAAADDRbMCxE/bc=
bstnA#
For detailed information about using this CLI command, refer to the ARX®
CLI Reference.
CLI Maintenance Guide
6-5
Chapter 6
Upgrading Software
Checking the Health of the Switch
After you copy your configuration, check the overall health of the ARX.
Use the show health command to check for any alarm conditions:
bstnA# show health
System Health Information
Date ID Event Description
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Wed Feb 27 04:12:02 2007 (0) ‐ No active alarms.
bstnA# ...
If any active alarms appear, contact F5 Support before proceeding.
Use the show cores command to confirm that no software processes failed
and created a core-memory file for diagnosis:
bstnA# show cores
cores
bstnA# ...
No core files appear in the above example. If any appear in your output,
address the root cause of all of them before continuing. Contact F5 Support
if you need assistance with diagnosis.
Checking the Log Files for Errors
Review the trap and error logs to see if any noteworthy events have
occurred. Execute show logs traplog and show logs error.log as appropriate,
and execute tail logs traplog and tail logs error.log to view the file contents, if
necessary. See Accessing the Syslog, on page 8-7 for complete information
about accessing and reading these files. Investigate and resolve any issues
that come to light.
Review the syslog to see if any noteworthy system events have occurred.
Execute show logs syslog and tail logs filename to list and view the syslog
files. See Accessing the Syslog, on page 8-7 for complete information about
accessing and reading these files. Investigate and resolve any issues that
come to light.
6-6
Changing the Software Release
Changing the Software Release
Clearing Space for a New Release File
Release files consume large amounts of disk space, so the ARX only stores
up to three release files (possibly more on some platforms). If your switch
has the maximum releases already, you must delete an unused release before
you copy a new one onto the chassis. Use the show releases command for a
listing of current release files:
show releases
This presents the files as a directory listing. Some files have single-letter
codes (R, A, or B) that signify how the switch is using the release file:
• R is the running release.
• A is the armed release, the one that will run on the next reboot. By
default, this is the same release as the running (R) release.
• B is the backup release. F5 personnel can revert the switch back to this
release if necessary.
For example, the command below shows three releases on the current
switch. The test1.rel file is currently running, and armed to run again on the
next reboot. The test2.rel file is the backup, for disaster recovery. The other
release file is unused, and is therefore a candidate for replacement:
bstnA(gbl‐ns[wwmed])# show releases
releases
R A test1.rel Dec 8 00:14 733M
B test2.rel Dec 7 00:06 733M
test3.rel Dec 7 03:55 623M
bstnA(gbl‐ns[wwmed])# ...
Showing the Software Versions
Use the show version command for a more-detailed view of the software
versions:
show version
This shows the specific versions of each release and the module
configuration for the chassis. For example:
bstnA(gbl‐ns[wwmed])# show version
Copyright (c) 2002‐2012 by F5 Networks, Inc. All rights reserved.
Running Release
test1.rel : Version 6.02.000.14342 (Mar 12 2012 20:07:15) [nbuilds]
Armed Release
test1.rel : Version 6.02.000.14342 (Mar 12 2012 20:07:15) [nbuilds]
Backup Release
test2.rel : Version 6.02.000.14334 (Feb 28 2012 17:47:10) [cdoyle]
CLI Maintenance Guide
6-7
Chapter 6
Upgrading Software
System Configuration: Version 602000.31
bstnA uptime is 0 weeks, 0 days, 1 hours, 31 minutes.
Slot Admin ModuleType ModuleState FW Upgrade
‐‐‐‐ ‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
1 Enabled ACM Online Disabled
2 Enabled NSM Online Disabled
Resource State Forwarding
‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
Switch Up Disabled
bstnA(gbl‐ns[wwmed])# ...
Deleting a Release File
You cannot delete the running, armed, or backup release. To delete any
other release file, go to priv-exec mode and use the delete releases
command:
delete releases file
where file (1-1024 characters) identifies the release file. You can use
wildcards (such as * for a string, ? for a single character, or [A-Z] for
any uppercase letter).
For example, the following command sequence exits to priv-exec mode,
deletes the test3.rel file, then shows the releases directory again to prove that
it is gone:
bstnA(gbl‐ns[wwmed])# end
bstnA# delete releases test1.rel
bstnA# show releases
releases
R A test1.rel Dec 8 00:14 733M
B test2.rel Dec 7 00:06 733M
bstnA# ...
Obtaining a New Release File
The next step in upgrading your software is to obtain a new release file from
F5. Use a host machine that can access the F5 web site. Ideally, this host
machine should be a client for an ARX CIFS or NFS service, or it should
serve FTP or SCP.
Start by opening a new web browser and going to this address:
https://downloads.f5.com/esd/productlines.jsp
Unless you were recently logged into an F5 web site, you reach a login page.
Enter your e-mail address (as a user name) and your password. If this is your
first time accessing the F5 web site, click on “Register for an Account” to
get a password.
6-8
Changing the Software Release
You reach the Downloads page after the F5 site accepts your credentials.
Navigate from this page to the desired ARX release, and follow the
instructions to download the release file to the current machine. Release
files are very large, so the download can take a long time.
If the current machine is a client for ARX-storage services, you can
download the file to any CIFS or NFS service on the ARX. For example, if
the machine has its F drive mapped to the “\\ac1.medarch.org\ARCHIVES”
share on the ARX, you can download it to “F:\admin\12345.rel.” If the
current machine is an FTP server or supports SCP, download it to a
directory that is accessible from the ARX.
If necessary, transfer the release file from this machine to another host that
meets the above criteria.
Copying a Release File to the Switch
The next step in upgrading software is to copy the new release file to the
ARX.
For cases where you copied the file into an ARX export or share (as
described above), you can find the ARX volume that holds the release file
and copy it from there to the “releases” directory. Other copy options,
through FTP or SCP, are discussed in the subsections below.
The copy command requires the specific namespace and volume where the
release file resides. Use show cifs-service fqdn for a map of fqdn’s
front-end CIFS shares to its ARX volumes; see Focusing on One CIFS
Service, on page 11-39 of the ARX® CLI Storage-Management Guide. For
an NFS export, use show nfs-service fqdn (Showing One NFS Service, on
page 11-8 of the same manual).
Then, from priv-exec mode, use copy cifs or copy nfs to copy the release
file to the “releases” directory:
copy {cifs|nfs} namespace volume file‐path releases dest‐file
where
cifs | nfs is a required choice. This is the network protocol used to
copy the release file out of the ARX volume.
namespace (1-30 characters) identifies the namespace. You can
find the correct namespace from the output of show cifs-service
or show nfs-service.
volume (1-1024 characters) is the volume name. For a CIFS share,
use the output of show cifs-service to find the volume name (such
as “/rcrds”) behind a share name (such as “ARCHIVES”). For an
NFS export, use the output of show nfs-service to find the volume
name.
file-path (1-1024 characters) is the path from the volume root
(above) to the release file.
releases is the destination directory.
CLI Maintenance Guide
6-9
Chapter 6
Upgrading Software
dest-file (1-1024 characters) is the name you choose for the local
copy of the release file.
For example, the following command sequence shows the namespace and
volume behind “\\ac1.medarch.org\ARCHIVES” (highlighted in bold text
below), copies the release file from that volume, then uses show releases to
confirm that the file was copied:
bstnA# show cifs‐service ac1.medarch.org
Service Name: ac1.MEDARCH.ORG Domain Join: Joined to MEDARCH.ORG Account Name: ac1$
Delegation: Constrained, Any Protocol
Delegate To: cifs/PV770N
cifs/PV770N.MEDARCH.ORG cifs/VM‐PV770N‐01
cifs/VM‐PV770N‐01.MEDARCH.ORG cifs/VM‐SWP2003S1‐5
cifs/VM‐SWP2003S1‐5.MEDARCH.ORG cifs/VM‐SWP2003S2‐04
cifs/VM‐SWP2003s2‐04.MEDARCH.ORG cifs/VM‐SWP2008S‐01
cifs/VM‐SWP2008S‐02
cifs/VM‐SWP2008s‐01.MEDARCH.ORG cifs/VM‐SWP2008s‐02.MEDARCH.ORG cifs/engdm
cifs/engdm.MEDARCH.ORG cifs/enterprise
cifs/enterprise.wwmed.com cifs/ntap‐prov
cifs/ntap‐prov.MEDARCH.ORG cifs/ntap820
cifs/ntap820.MEDARCH.ORG Description: insurance‐claim records
State: Enabled
Signatures: Enabled
WINS Name Encoding: ISO‐8859‐1
Exports for Namespace: insur
Share Name Volume Path State
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐
CLAIMS /claims Online
SPECS /claims/specs Online
STATS /claims/stats Online
Exports for Namespace: medarcv
Share Name Volume Path State
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐
ARCHIVES /rcrds Online
...
bstnA# copy cifs medarcv /rcrds admin/12345.rel releases test5.rel
% INFO: Copying 1050 megabytes from the specified source . . .
...
% INFO: Transferred 742 of 1050 megabytes; still copying . . .
6 - 10
Changing the Software Release
% INFO: The copy source file '12345.rel' to destination file 'test5.rel' completed successfully.
bstnA# show releases
releases
R A test1.rel Dec 8 00:14 733M
B test2.rel Dec 7 00:06 733M
test5.rel Sep 10 00:09 794M
bstnA# ...
Downloading From an FTP Server
If the client machine supports FTP transfers to the ARX, you can use copy
ftp instead:
copy ftp://[username:password@]ftp-site/file releases dest-file
where
username:password@ (optional) is an FTP username and
password (the default is the username/password set by the ip
ftp-user command; see Setting a Default FTP or SCP User, on page
5-3),
ftp-site identifies the FTP server with an IP address or FQDN (for
example, “172.16.88.3” or “ftp.myftpsite.com”),
file is the chosen file name (lead with two slashes (ftp-site//file) if
the file path is absolute),
releases is the destination directory on the ARX, and
dest-file is the name you choose for the local copy of the release
file.
For example, the following command sequence copies a release file from
mysrv.wwmed.com, then uses show releases to confirm that the file was
copied:
bstnA# copy ftp://jusr:jpasswd@mysrv.wwmed.com/12345.rel releases test5.rel
% INFO: Copying 1050 megabytes from the specified source . . .
...
% INFO: The copy completed successfully.
bstnA# show releases
releases
R A test1.rel Dec 8 00:14 733M
B test2.rel Dec 7 00:06 733M
test5.rel Sep 10 00:09 794M
bstnA# ...
CLI Maintenance Guide
6 - 11
Chapter 6
Upgrading Software
Downloading From an SCP Server
For secure sites, you can download the release file with the Secure Copy
(SCP) protocol. The URL has a different syntax for SCP transfers:
copy scp://username@server:file releases dest‐file [accept‐host‐key]
where
username@ is a valid username at the remote host,
server identifies the SCP server with an IP address or FQDN (for
example, “172.16.100.18” or “deb1.mynet.com”), and
file is the release-file name. Lead with a slash (scp-server:/file) if
the file path is absolute. Without the slash, the path is presumed to
start in the home directory for username.
dest-file is the name you choose for the downloaded copy of the
release file.
accept-host-key (optional) tells the CLI to accept an unknown host
key if offered by the SCP server. The host key authenticates the
server; if the key is unknown, it is possible that an attacker has
taken the server’s hostname and/or IP address. Note that any SCP
server is “unknown” if the ARX has not had an SCP exchange with
it since the ARX’s last reboot.
The CLI prompts for the username’s password. Enter a password that is
valid at the remote site. For example, the following command exits from gbl
mode to priv-exec mode, then downloads a release file through SCP:
bstnA(gbl)# exit
bstnA# copy scp://juser@rh1.wwmed.com:/var/rels/12345.rel releases test.rel
Password: jpasswd
% INFO: Copying 1050 megabytes from the specified source . . .
...
bstnA# ...
Showing the Version of a Release File
Use the show releases command on a release file to view the release version
and build date for the file:
show releases file
where file (1-1024 characters) is the release-file name.
This shows the version number, time/date when the release was built, and
the user that performed the build (typically, “nbuilds”). For example:
bstnA# show releases test5.rel
Version 6.03.000.14767 (Jul 27 2012 20:18:27) [nbuilds]
bstnA# ...
6 - 12
Changing the Software Release
Validating the Release File
It is possible for the release file to be incomplete after it downloads. You
can verify the integrity of the file by comparing its current checksum, a file
signature based on its contents, against the checksum it had when it was
built. Use the verbose option in the show releases command to run a
checksum test on the release file:
show releases file verbose
A successful checksum shows as “Passed” in the output. For example:
bstnA# show releases test5.rel verbose
Version 6.03.000.14767 (Jul 27 2012 20:18:27) [nbuilds]
Checksum: Passed
bstnA# ...
If the checksum fails, retry the copy command and/or retry the download
from the F5 web site.
Arming the Switch with the Release File
The next step in upgrading software is to arm the switch with the new
release file. From priv-exec mode, use the boot system command to arm the
ARX:
boot system release‐file
where release-file (1-1024 characters) identifies the desired release file.
On a busy system, this can take more than one minute.
Note
If you are downgrading to an earlier release, this command removes all of
your configuration parameters. After the next reboot, all managed volumes
will disappear from the configuration; to recover, you must restore the
running-config and global-config files (saved earlier) to re-import all
managed volumes. The CLI warns of this and prompts for confirmation;
confirm that you have saved your config and enter yes to continue.
As an upgrade example, the following command sequence arms the switch
with the “test5.rel” file and then verifies that the switch is properly armed:
bstnA# boot system test5.rel
% INFO: The boot system command may take up to 5 minutes to complete.
bstnA# show releases
releases
R test1.rel Dec 8 00:14 733M
test2.rel Dec 7 00:06 733M
A B test5.rel Sep 10 00:09 794M
bstnA# ...
CLI Maintenance Guide
6 - 13
Chapter 6
Upgrading Software
Rebooting the Switch
The final step in upgrading software is to reboot the switch and activate the
armed release file. From priv-exec mode, use the reload command to reboot
the switch:
reload
The CLI prompts for confirmation before rebooting; enter yes to proceed.
For example:
bstnA# reload
Reload the entire chassis? [yes/no/diags] yes
System is resetting.
...
Activating the Software License (If Necessary)
If you have ever activated the license for this ARX, you can skip this
subsection.
When a user logs in to the ARX for the first time after license-aware
software is loaded, the message of the day announces that the ARX is not
licensed. The ARX also sends an SNMP trap to this effect.
Contact your Sales representative to get your base-registration key, which is
required to activate the license for the first time. The key usually comes in
an E-mail message. Then use automatic or manual license activation, as
appropriate for your installation. For details on license activation, see
Chapter 5, ARX Feature Licensing in the ARX® CLI Network-Management
Guide.
For example:
...
User Access Authentication
Username: admin
Password: password
...
bstnA> enable
bstnA# ping license‐server base‐reg‐key CRJGVQP‐DYWST‐ANKR‐GBYYDMT
% INFO: Activation server response: 'Thu Aug 25 04:28:00 UTC 2011'
bstnA# license activate base‐reg‐key CRJGVQP‐DYWST‐ANKR‐GBYYDMT
% INFO: The license has been successfully activated.
bstnA#
If the license activation fails and cannot be resolved, you must arm the ARX
with the former release and use reload to go back to it (go back to Arming
the Switch with the Release File, on page 6-13).
6 - 14
Changing the Software Release
Rebuilding the Configuration (Downgrade Only)
This section applies to a downgrade, where the new release has a lower
number than the former release. Skip to the next section if you are upgrading
to a higher release.
When the downgraded switch returned from its reboot and you logged back
in, a notice informed you that the running-config has been reset to factory
defaults. For example:
...
User Access Authentication
Username: admin
Password: password
************************ NOTICE *********************
The system detected an incompatible future version
of its configuration‐database file(s).
The following file(s) have been automatically backed up.
complete database: omDb.complete.copy.Dec03_1534
The current running‐config has been reset to factory
defaults, plus the minimal configuration obtained during
system initialization.
If the software on this system has NOT recently been
upgraded or downgraded, we advise you to restore the
running‐config and/or global‐config from a recent backup.
Otherwise, please use individual CLI commands to upgrade
or downgrade in smaller steps.
************************ NOTICE ***********************
SWITCH> ...
This indicates that you need to restore the running-config and the
global-config, saved off at the beginning of this process (recall Saving the
Configuration, on page 6-19). First, edit both configuration files to remove
all commands that do not exist in the older release. Contact F5 Support if
you need assistance.
Once the running-config and global-config files are edited for the
downgrade release, use the copy command to copy the files to the ARX.
Then use the run configs command to invoke each of them as a script. Run
the running-config script first, followed by the global-config script. For
example, the following commands replace the previously stored configs:
SWITCH> enable
SWITCH# copy ftp://juser:jpasswd@ftp.wwmed.com/net_config configs running‐config
SWITCH# run configs running‐config
...
bstnA# copy ftp://juser:jpasswd@ftp.wwmed.com/storage_config configs global‐config
bstnA# run configs global‐config
...
CLI Maintenance Guide
6 - 15
Chapter 6
Upgrading Software
Verifying the Installation
The new release is running when the switch reboots. Log back in and use
show version to verify that the software upgrade was successful. For
example:
...
User Access Authentication
Username: admin
Password: acopia
bstnA> show version
Copyright (c) 2002‐2012 by F5 Networks, Inc. All rights reserved.
Running Release
test1.rel : Version 6.03.000.14767 (Jul 27 2012 20:18:27) [nbuilds]
Armed Release
test1.rel : Version 6.02.000.14342 (Mar 12 2012 20:07:15) [nbuilds]
Backup Release
test2.rel : Version 6.02.000.14334 (Feb 28 2012 17:47:10) [cdoyle]
System Configuration: Version 603000.2
bstnA uptime is 0 weeks, 0 days, 1 hours, 31 minutes.
Slot Admin ModuleType ModuleState FW Upgrade
‐‐‐‐ ‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
1 Enabled ACM Online Disabled
2 Enabled NSM Online Disabled
Resource State Forwarding
‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
Switch Up Disabled
bstnA> ...
6 - 16
Checking for New Firmware
Checking for New Firmware
Firmware upgrade and downgrade is not supported for ARX-VE. Skip to the
next section if you are changing the release on that platform.
A software release may contain new firmware for the switch’s hardware
modules. The firmware is low-level software that controls the boot process
and various FPGAs.
You can use the show firmware upgrade command to compare the running
firmware with the firmware that is available on the new release:
show firmware upgrade [verbose]
where verbose (optional) expands the output with specific version
numbers for each firmware component.
The non-verbose output shows a table of slots with an indication of which
have a firmware upgrade available. For example, the following chassis has
current firmware for all of its slots:
bstnA# show firmware upgrade
Show Firmware Update
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Slot Status Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 Up to date
2 Up to date
bstnA# ...
Upgrading Firmware
If the show firmware upgrade output indicates that a firmware upgrade is
available for any of your slots, you can use the firmware upgrade all
command to upgrade all slots at once.
Important
This takes several minutes and causes up to three automatic reboots.
Contact F5 Support before upgrading firmware.
Run this command from priv-exec mode:
firmware upgrade all
The CLI prompts for confirmation before upgrading any firmware. Enter
yes to proceed.
For example:
bstnA# firmware upgrade all
Confirmation of this command commences a firmware upgrade on the entire chassis. During the upgrade process, the chassis reboots automatically to complete the upgrade process. If this includes a bios upgrade, this could take at least 30 minutes.
Proceed? [yes/no] yes
...
CLI Maintenance Guide
6 - 17
Chapter 6
Upgrading Software
Sanity Check
When the upgraded switch returns from the reboot, log in and check the
basic health of the system:
• use show processors to confirm that the processors are all “Up” or (for
network processors) in “Standby” state,
• use show health to verify there are no active alarms, and
If any issues arise, contact F5 Support before proceeding further.
6 - 18
Upgrading a Redundant Pair
Upgrading a Redundant Pair
Redundancy offers an opportunity to test new software before putting it into
service. You can coordinate the software upgrades by upgrading the backup
switch first, testing it there, then deciding whether or not to upgrade its peer.
Note
Redundant, high-availability support for the ARX-VE is available via
standard hypervisor clustering functionality. These instructions for
upgrading a redundant ARX pair do not apply to the ARX-VE.
Saving the Configuration
To prepare for a possible upgrade failure, save the running-config of the
Backup switch. These configuration parameters will be invaluable if you
decide to revert to the old release after the upgrade.
For example, the following command copies the running-config and the
global-config to an FTP server at ftp.wwmed.com:
prtlndB# copy running‐config ftp://juser:jpasswd@ftp.wwmed.com/runConfPrtlndB
% INFO: The copy command completed successfully.
prtlndB# copy global‐config ftp://juser:jpasswd@ftp.wwmed.com/gbl_config_prtlnd
% INFO: The copy command completed successfully.
prtlndB# ...
Then record these configuration parameters:
• the password for the administrative account (named “admin” by default)
and
• the encrypted master key.
Refer back to Other Important Configuration Parameters, on page 6-5 for
more details and examples.
Verifying the Active Switch’s Ability to Stand Alone
Before you upgrade one of the switches, confirm that the chosen Active
switch (the switch that you will not upgrade first) is connected to the
quorum disk. The Active switch must be connected to the quorum disk when
you upgrade its peer, or both switches reboot simultaneously. Use the show
redundancy quorum-disk command to verify the connection to the quorum
disk (see Showing the Quorum Disk, on page 7-22 of the ARX® CLI
CLI Maintenance Guide
6 - 19
Chapter 6
Upgrading Software
Network-Management Guide). Run this command at the Active switch, not
the switch where you will do the upgrade first. Any “Up” status, even if the
switch is not receiving heartbeats, is acceptable.
Important
Verify that the quorum disk is fast and reliable, too. Quorum-disk transitions
should be very rare, and latency should be typically low. If the transition
count is high, the last transition is recent, or the latency is high, you may
want to choose a faster/more-reliable quorum disk before you perform the
upgrade. Select another disk by changing it on both peers, one after the
other.
For example, the “prtlndA” is ready to take Active service during an
upgrade:
prtlndA# show redundancy quorum‐disk
Path: 192.168.74.83:/exports/quorum‐disk/portland1
Protocol: nfs2
Status: Up
Heartbeats
Sent: 744
Received: 741
Transitions
Count: 1
Last: 05:33:07 09/14/2009
Reason: Quorum disk 192.168.74.83:/exports/quorum‐disk/portland1 is now online.
Heartbeat Latency:
Heartbeat Latency Intervals (msec)
Time Interval [0‐499] [500‐999] [1000‐3999] [No Response]
‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
01:00 ‐ 01:45 745 0 0 0
00:00 ‐ 01:00 0 0 0 0
23:00 ‐ 24:00 0 0 0 0
22:00 ‐ 23:00 0 0 0 0
21:00 ‐ 22:00 0 0 0 0
20:00 ‐ 21:00 0 0 0 0
19:00 ‐ 20:00 0 0 0 0
18:00 ‐ 19:00 0 0 0 0
17:00 ‐ 18:00 0 0 0 0
16:00 ‐ 17:00 0 0 0 0
15:00 ‐ 16:00 0 0 0 0
14:00 ‐ 15:00 0 0 0 0
13:00 ‐ 14:00 0 0 0 0
12:00 ‐ 13:00 0 0 0 0
11:00 ‐ 12:00 0 0 0 0
10:00 ‐ 11:00 0 0 0 0
09:00 ‐ 10:00 0 0 0 0
08:00 ‐ 09:00 0 0 0 0
07:00 ‐ 08:00 0 0 0 0
06:00 ‐ 07:00 0 0 0 0
05:00 ‐ 06:00 0 0 0 0
04:00 ‐ 05:00 0 0 0 0
03:00 ‐ 04:00 0 0 0 0
02:00 ‐ 03:00 0 0 0 0
6 - 20
Upgrading a Redundant Pair
Heartbeat latency summary:
0‐499msec : 100.00%
500‐999 msec : 0.00%
1000‐3999 msec : 0.00%
No response : 0.00%
prtlndA# ...
Checking the Health of the Backup Switch
From the backup switch, use the show redundancy command to confirm that
the redundant pair is formed. Both peers and the quorum disk should all
have a status of “Up.” For example,
prtlndB# show redundancy
Transitions
Node Switch/Quorum Disk Status Role Total Last (UTC)
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 prtlndA Up Active 1 05:33:19 09/14/2009
*2 prtlndB Up Backup Never ‐
QD 192.168.74.83 Up Quorum 1 05:33:07 09/14/2009
prtlndB# ...
If the status is not “Up” for any of the nodes, contact F5 Support before
proceeding.
Otherwise, use the show health command to check for any alarm conditions:
prtlndB# show health
System Health Information
Date ID Event Description
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Wed Feb 28 04:45:02 2007 (0) ‐ No active alarms.
prtlndB# ...
If any active alarms appear, contact F5 Support before proceeding.
Use the show cores command to confirm that no software processes failed
and created a core-memory file for diagnosis:
prtlndB# show cores
cores
prtlndB# ...
No core files appear in the above example. If any appear in your output,
address the root cause of all of them before continuing.
Upgrading the Backup Switch
The next step is to upgrade the Backup switch as described earlier. For
example, the following command sequence downloads a new software
release, new.rel, arms the switch with the new release, and reloads the
system:
prtlndB# copy ftp://jusr:jpasswd@mysrv.wwmed.com/12345.rel releases new.rel
CLI Maintenance Guide
6 - 21
Chapter 6
Upgrading Software
% INFO: Copying 1050 megabytes from the specified source . . .
...
% INFO: Transferred 742 of 1050 megabytes; still copying . . .
% INFO: The copy source file '12345.rel' to destination file 'new.rel' completed successfully.
prtlndB# boot system new.rel
% INFO: The boot system command may take up to 5 minutes to complete.
prtlndB# reload
Reload the entire chassis? [yes/no/diags] yes
System is resetting.
...
Activating the License (If Necessary)
If you have ever activated the license for this ARX, you can skip this
subsection.
When the ARX is running for the first time with license-aware software, the
software license must be activated. A message on the system console
announces this when you log in, as does an SNMP trap.
Contact your Sales representative to get your base-registration key, which is
required to activate the license for the first time. The key usually comes in
an E-mail message. Then use automatic or manual license activation, as
appropriate for your installation. For details on license activation, see
Chapter 5, ARX Feature Licensing in the ARX® CLI Network-Management
Guide.
For example, this command sequence logs in after the reboot, pings the
ARX license server, and then performs an automatic activation:
...
User Access Authentication
Username: admin
Password: password
...
prtlndB# ping license‐server base‐reg‐key CYBJAAZ‐DYWST‐ANKR‐GBYYDMT
% INFO: Activation server response: 'Thu Aug 25 04:28:00 UTC 2011'
prtlndB# license activate base‐reg‐key CYBJAAZ‐DYWST‐ANKR‐GBYYDMT
% INFO: The license has been successfully activated.
prtlndB#
If the license activation fails and cannot be resolved, you must reload and
boot the former release of software (see Upgrading the Backup Switch, on
page 6-21).
6 - 22
Upgrading a Redundant Pair
Checking for New Firmware
Firmware upgrade and downgrade is not supported for ARX-VE. Skip to the
next section if you are changing the release on that platform.
If this platform supports firmware upgrades, use the show firmware upgrade
command to compare the running firmware with the firmware that is
available on the new release. For example, the following chassis has new
firmware available for its only slot:
prtlndB# show firmware upgrade
Show Firmware Update
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Slot Status Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 Upgrade available
prtlndB# ...
Upgrading Firmware
If the show firmware upgrade output indicates that a firmware upgrade is
available for any of your slots, you can use the firmware upgrade all
command to upgrade all slots at once.
Important
This takes several minutes and causes an automatic reboot. Contact F5
Support before upgrading firmware.
For example:
prtlndB# firmware upgrade all
Confirmation of this command commences a firmware upgrade on the entire chassis. During the upgrade process, the chassis reboots automatically to complete the upgrade process. If this includes a bios upgrade, this could take at least 30 minutes.
Proceed? [yes/no] yes
...
Sanity Check
When the upgraded switch returns from the reboot, log in and check the
basic health of the system. This switch is still in the backup role:
• use show processors to confirm that the processors are all “Up” or (for
network processors) in “Standby” state,
• use show health to verify there are no active alarms, and
• use show redundancy to ensure that redundancy is up and running.
If any issues arise, contact F5 Support before proceeding further.
CLI Maintenance Guide
6 - 23
Chapter 6
Upgrading Software
Checking the Health of the Active Switch
Repeat the health checks at the active switch, where the previous release is
still running. Use the show redundancy command to confirm that the
redundant pair is formed, and use show health to verify that there are no
active alarms. Both peers and the quorum disk should all have a status of
“Up,” and there should be no active alarms.
If the status is not “Up” for any of the nodes, or if any active alarms appear,
contact F5 Support before proceeding.
Failing Over to the Upgraded Switch
The next step is to fail over and put the new software into active service.
Reload the other switch, the switch currently running services on the old
software. Use the priv-exec reload command. This forces failover to the
switch running the new software. From the now-active switch (“prtlndB” in
our examples), take the following steps to confirm that the failover
succeeded:
• Repeat show cifs-service all and/or show nfs-service all until all of
your configured services have a “State” of “Online.”
• From a client machine, test all NFS exports and/or CIFS shares on the
ARX.
• Repeat show redundancy until the now-backup peer has re-joined the
pair in the “Backup” role. Confirm that the both peers and the quorum
disk all have a “Status” of “Up.”
The failover should be complete and the above tests should pass after five
minutes at most. Contact F5 Support if the failover takes more time or if any
of the above tests fail.
Testing the New Release
The new release can process client traffic with the same configuration that
was in use before the upgrade. This is an opportunity to verify the integrity
of the new release with standard client traffic. However, none of the
release’s new global-mode features are available until after you upgrade
both peers: the CLI does not allow you to enter gbl mode, and the GUI does
not offer any storage-management or policy features.
From here, there are two paths to follow: the success path (you want to
deploy the new software) or the failure path (you want to continue running
the old software).
6 - 24
Upgrading a Redundant Pair
Success Path
Upgrade the peer switch (now in the Backup role) to the new release. Use
the same steps that you used above, from Saving the Configuration, on page
6-19 to Sanity Check, on page 6-23. Then both switches are running the new
software, and all new global-configuration options are now available.
You must invoke one additional failover after both peers have been
upgraded. The final failover, with both peers at the new software version,
makes it possible to perform the final upgrade of internal databases and
enable any new features that are database-dependent. To return the
originally-active peer (“prtlndA” in our examples) to its active status, use
reload on the currently-active peer (“prtlndB”). This causes a failover.
Failure Path
To return to the old release, you can revert the now-Active switch to the old
software. First use reload to fail back to the peer switch, which is still
running the previous release. When this switch boots (now in the backup
role), use boot system to select the old release, then use reload to install it.
Downgrading deletes all configuration parameters, both the running-config
and the global-config; a CLI prompt asks for confirmation before doing this.
Recall that you saved the global-config and running-config files earlier, in
Saving the Configuration, on page 6-19.
For example:
prtlndB# reload
Reload the entire chassis? [yes/no] yes
Broadcast message (Thu Sep 10 13:27:12 2009):
The system is going down for reboot NOW!
...
prtlndB# boot system oldRelease.rel
WARNING: Arming this release will cause your configuration to be reset to factory default because it is a lower version than the running release.
Proceed? [yes/no] yes
% INFO: The boot system command may take up to 5 minutes to complete.
prtlndB# reload
Reload the entire chassis? [yes/no/diags] yes
System is resetting.
...
When the downgraded switch returns from its reboot and you log back in, a
notice informs you that the running-config has been reset to factory defaults.
For example:
...
User Access Authentication
CLI Maintenance Guide
6 - 25
Chapter 6
Upgrading Software
Username: admin
Password: password
************************ NOTICE *********************
The system detected an incompatible future version
of its configuration‐database file(s).
The following file(s) have been automatically backed up.
complete database: omDb.complete.copy.Dec03_1534
The current running‐config has been reset to factory
defaults, plus the minimal configuration obtained during
system initialization.
If the software on this system has NOT recently been
upgraded or downgraded, we advise you to restore the
running‐config and/or global‐config from a recent backup.
Otherwise, please use individual CLI commands to upgrade
or downgrade in smaller steps.
************************ NOTICE ***********************
SWITCH> ...
Restoring the Old Configuration
The final step in reverting to the old software is to restore the old
running-config parameters, saved off at the beginning of this process (recall
Saving the Configuration, on page 6-19). The global-config is still running
on the active peer (prtlndA in the examples), so that does not need to be
restored. Use the copy command to copy the file to the ARX. Then use the
run configs running-config command to invoke it as a script.
For example, the following commands replace the previously stored
running-config:
SWITCH> enable
SWITCH# copy ftp://juser:jpasswd@ftp.wwmed.com/runConfPrtlndB configs running‐config
Overwrite existing file 'running‐config' in directory 'configs'? [yes/no] yes
% INFO: Transferred 0 megabytes; still copying . . .
% INFO: The copy of source file 'runConfPrtlndB' to destination file 'running‐config' completed successfully.
SWITCH# run configs running‐config
SWITCH‐ config
SWITCH(cfg)‐ vlan 405
...
prtlndB(cfg)#
6 - 26
Downgrading a Redundant Pair
Downgrading a Redundant Pair
Downgrades are against best practices, but may be necessary in some rare
cases. This causes a temporary service outage. We recommend that you
perform this procedure during off-peak hours, and only under the guidance
of F5 Support.
Note
Redundant, high-availability support for the ARX-VE is available via
standard hypervisor clustering functionality. These instructions for
downgrading a redundant ARX pair do not apply to the ARX-VE.
Saving the Configuration
The system removes the entire configuration database as part of a
downgrade. To prepare for this, save the running-config (network
parameters) for both peers, and save the global-config (storage parameters,
shared between the peers) from either of them. The global-config is shared,
so it does not matter which peer you save it from.
For example, the following command copies the running-config and the
global-config from the backup peer, “prtlndB,” to an FTP server at
ftp.wwmed.com:
prtlndB# copy running‐config ftp://juser:jpasswd@ftp.wwmed.com/runConfPrtlndB
% INFO: The copy command completed successfully.
prtlndB# copy global‐config ftp://juser:jpasswd@ftp.wwmed.com/gbl_config_prtlnd
% INFO: The copy command completed successfully.
prtlndB# ...
To continue the example, this command copies the running-config for the
active peer, “prtlndA,” to the same FTP server:
prtlndA# copy running‐config ftp://juser:jpasswd@ftp.wwmed.com/runA
% INFO: The copy command completed successfully.
prtlndA# ...
Then record these configuration parameters:
• the password for the administrative account (named “admin” by default)
and
• the encrypted master key.
These parameters are shared between the peers, like the global-config. Refer
back to Other Important Configuration Parameters, on page 6-5 for more
details and examples.
CLI Maintenance Guide
6 - 27
Chapter 6
Upgrading Software
Editing the Config Files
The config files may have commands that are unknown in the downgrade
release. Edit them all to remove any such commands. You can use the CLI
Reference manual from the downgrade release to check for the existence and
syntax of any given command in the release.
Additionally, remove the cfg-redundancy enable command from both
running-config files. When you run the config files as scripts later, you will
want to control the timing for re-enabling redundancy. For example, this
shows the end of the running-config file for the “prtlndB” switch. Comment
out or remove the enable command, shown here in bold text:
...
exit
;=========================== ntp server config ===========================
ntp server 192.168.74.104 version 4
;============================ cfg‐redundancy =============================
redundancy
peer 10.1.23.11
quorum‐disk 192.168.74.83:/exports/quorum‐disk/portland1 nfs2
critical route 0.0.0.0 0.0.0.0
enable
exit
exit
Remove the same command(s) from the running-config for the active
switch, too.
Downgrading the Backup Switch
The next step is to downgrade the Backup switch. This is the same as the
upgrade process described earlier, except that you choose a release with a
lower release number. Typically, the older release is already on the ARX.
Use the boot system command to arm the system with the older release,
and then reload with it. The boot system command causes the next reload
to erase the entire configuration, so the CLI prompts you for confirmation
first; this is necessary for the downgrade, so enter yes to proceed.
For example, the following command sequence arms the switch with an
older release and reloads the system:
prtlndB# boot system old.rel
WARNING: Arming this release will cause your configuration to be reset to factory default because it is a lower version than the running release.
Proceed? [yes/no] yes
% INFO: The boot system command may take up to 5 minutes to complete.
prtlndB# reload
Reload the entire chassis? [yes/no/diags] yes
6 - 28
Downgrading a Redundant Pair
System is resetting.
...
Rebuilding the Running-Config
When the downgraded switch returns from its reboot and you log back in, a
notice informs you that the running-config has been reset to factory defaults.
For example:
...
User Access Authentication
Username: admin
Password: password
************************ NOTICE *********************
The system detected an incompatible future version
of its configuration‐database file(s).
The following file(s) have been automatically backed up.
complete database: omDb.complete.copy.Dec03_1534
The current running‐config has been reset to factory
defaults, plus the minimal configuration obtained during
system initialization.
If the software on this system has NOT recently been
upgraded or downgraded, we advise you to restore the
running‐config and/or global‐config from a recent backup.
Otherwise, please use individual CLI commands to upgrade
or downgrade in smaller steps.
************************ NOTICE ***********************
SWITCH> ...
This indicates that you need to restore the running-config, saved off and
edited at the beginning of this process (recall Saving the Configuration, on
page 6-27).
Once the running-config file is edited for the downgrade release (recall
Editing the Config Files, on page 6-28), use the copy command to copy the
file to the ARX. The CLI prompts for confirmation before overwriting the
current running-config file; enter yes to proceed. Then use the run configs
running-config command to invoke it as a script.
For example, the following commands replace the previously stored
running-config:
SWITCH> enable
SWITCH# copy ftp://juser:jpasswd@ftp.wwmed.com/runConfPrtlndB configs running‐config
Overwrite existing file 'running‐config' in directory 'configs'? [yes/no] yes
% INFO: Transferred 0 megabytes; still copying . . .
% INFO: The copy of source file 'runConfPrtlndB' to destination file 'running‐config' completed successfully.
CLI Maintenance Guide
6 - 29
Chapter 6
Upgrading Software
SWITCH# run configs running‐config
SWITCH‐ config
SWITCH(cfg)‐ vlan 405
...
prtlndB#
Checking for New Firmware
Firmware downgrade is not supported for ARX-VE. Skip to the next section
if you are changing the release on that platform.
If this platform supports firmware downgrades, use the show firmware
upgrade command to compare the running firmware with the firmware that
is available on the downgrade release. For example, the following chassis
has new firmware available for its only slot:
prtlndB# show firmware upgrade
Show Firmware Update
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Slot Status Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 Upgrade available
prtlndB# ...
Upgrading Firmware
If the show firmware upgrade output indicates that a firmware change is
available for any of your slots, you can use the firmware upgrade all
command to change all slots at once.
Important
This takes several minutes and causes an automatic reboot. Contact F5
Support before downgrading firmware.
For example:
prtlndB# firmware upgrade all
Confirmation of this command commences a firmware upgrade on the entire chassis. During the upgrade process, the chassis reboots automatically to complete the upgrade process. If this includes a bios upgrade, this could take at least 30 minutes.
Proceed? [yes/no] yes
...
6 - 30
Downgrading a Redundant Pair
Sanity Check
After checking the firmware on the downgraded switch, check the basic
health of the system:
• use show processors to confirm that the processors are all “Up” or (for
network processors) in “Standby” state, and
• use show health to verify there are no active alarms other than
"licenseNotFoundRaise." The license is supposed to be disabled at the
moment because the peer ARX is still the active peer (and possibly in
service), so it has registered all the proxy-IP addresses for this current
ARX through ARP. Enabling the license would cause the current switch
to gratuitously ARP all of its proxy IPs, creating contention for those
addresses between the two ARX devices.
If any issues arise, contact F5 Support before proceeding further.
Downgrading the Active Switch
You must manually erase all configuration parameters from the active peer
before you downgrade it. You cannot use the boot system command on an
active peer, and the active peer cannot fail over if the redundant peer is
running a lower release, so you must erase the device’s configuration before
you perform the downgrade. Use the delete startup-config command,
followed by a reload, to erase all of the configuration from the active peer.
Recall that you already saved the configuration earlier, and edited it for use
at the older release level.
Important
This causes a service outage. This outage is unavoidable for downgrades.
The CLI prompts for confirmation at each command, to warn you of the
configuration outage and the loss of service; enter yes for both commands.
For example, the following command sequence removes the configuration
from “prtlndA” and reloads the switch:
prtlndA# delete startup‐config
Delete file 'startup‐config' in directory 'configs'? [yes/no] yes
prtlndA# reload
You had previously deleted your startup‐config.
If you would like to restore your configuration,
answer 'no' to cancel this reload and then run the
'restore startup‐config' CLI command before
re‐running this command. If you answer 'yes'
instead, the ARX returns to its factory defaults.
The redundant peer is unable to take over services at this time. Reload? [yes/no/diags] yes
System is resetting.
...
CLI Maintenance Guide
6 - 31
Chapter 6
Upgrading Software
Downgrading the Release
The next step is to downgrade the release. This is similar to downgrading the
release on the backup switch. Typically, the older release is already on the
ARX.
For example, the following command sequence arms the active switch with
an older release and reloads the system:
...
User Access Authentication
Username: admin
Password: password
Running‐config last saved 1/7 by J. User
ARX software must be licensed. Please configure DNS for automatic license activation.
SWITCH> enable
SWITCH# boot system old.rel
% INFO: The boot system command may take up to 5 minutes to complete.
SWITCH# reload
Reload the entire chassis? [yes/no/diags] yes
System is resetting.
...
Rebuilding the Running-Config
When the downgraded switch returns from its reboot, restore its
running-config. Use the running-config that you saved off and edited at the
beginning of this process (recall Saving the Configuration, on page 6-27).
Use the copy command to copy the edited running-config file to the ARX.
The CLI prompts for confirmation before overwriting the current
running-config file; enter yes to proceed. Then use the run configs
running-config command to invoke it as a script.
The running-configs are unique to each switch; be careful to use the correct
running-config file.
For example, the following commands replace the previously stored
running-config for “prtlndA:”
User Access Authentication
Username: admin
Password: password
6 - 32
Downgrading a Redundant Pair
Running‐config last saved 1/7 by J. User
ARX software must be licensed. Please configure DNS for automatic license activation.
SWITCH> enable
SWITCH# copy ftp://juser:jpasswd@ftp.wwmed.com/runA configs running‐config
Overwrite existing file 'running‐config' in directory 'configs'? [yes/no] yes
% INFO: Transferred 0 megabytes; still copying . . .
% INFO: The copy of source file 'runA' to destination file 'running‐config' completed successfully.
SWITCH# run configs running‐config
SWITCH‐ config
SWITCH(cfg)‐ vlan 405
...
prtlndA#
Activating the License
The downgrade erases all traces of a former license activation along with the
configuration database. If the license was activated previously, you can use
the license activate command (without a base-registration key) to
re-activate it after the downgrade. (For details on license activation, see
Chapter 5, ARX Feature Licensing in the ARX® CLI Network-Management
Guide.)
For example:
prtlndA# license activate
% INFO: The license has been successfully activated.
prtlndA#
CLI Maintenance Guide
6 - 33
Chapter 6
Upgrading Software
Checking for New Firmware
Firmware downgrade is not supported for ARX-1500, ARX-2500, or
ARX-VE. Skip to the next section if you are changing the release on any of
these platforms.
If this platform supports firmware downgrades, use the show firmware
upgrade command to compare the running firmware with the firmware that
is available on the downgrade release. If a change is necessary, use the
firmware upgrade all command. For example, the following chassis has all
of its firmware up-to-date:
prtlndA# show firmware upgrade
Show Firmware Update
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Slot Status Summary
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 Up to date
prtlndA# ...
Restoring the Global-Config and Restoring (Standalone) Service
The next step in reverting to the old software is to restore the old
global-config parameters, saved off and edited at the beginning of this
process (recall Saving the Configuration, on page 6-27). Use the copy
command to copy the global-config file to the ARX. Then use the run
configs global-config command to invoke it as a script.
This re-imports all managed volumes and restores all VIPs to service. Until
later in the procedure, storage services are offered on a standalone ARX.
For example, the following commands replace the previously stored and
edited global-config:
prtlndA# copy ftp://juser:jpasswd@ftp.wwmed.com/gbl_config_prtlnd configs global‐config
Overwrite existing file 'global‐config' in directory 'configs'? [yes/no] yes
% INFO: The copy of source file 'gbl_config_prtlnd' to destination file 'global‐config' completed successfully.
prtlndA# run configs global‐config
prtlndB‐ global
prtlndB(gbl)‐ user adm1 encrypted‐password wVHZxkyYpVFNLma0Pl/XtoqvYOYPtwhjXt2QkzyLfLc=
prtlndB(gbl‐user[adm1])‐ exit
...
prtlndA#
6 - 34
Downgrading a Redundant Pair
Sanity Check
After re-running the global-config on the downgraded switch, check the
basic health of the system:
• use show processors to confirm that the processors are all “Up” or (for
network processors) in “Standby” state,
• use show health to verify there are no active alarms, and
• use show redundancy to ensure that redundancy is not currently running.
If any issues arise, contact F5 Support before proceeding further.
Activating the License on the Originally-Backup Peer
The originally-backup peer (prtlndB in the examples) still has a disabled
license. It needs its license enabled before it can rejoin the redundant pair. If
the license was ever activated previously, you can use the license activate
command (without a base-registration key) to re-activate it after the
downgrade. For details on license activation, see Chapter 5, ARX Feature
Licensing in the ARX® CLI Network-Management Guide.
For example:
prtlndB# license activate
% INFO: The license has been successfully activated.
prtlndB#
Restoring Redundancy
The originally-active switch, “prtlndA” in the examples, is now running the
downgrade release as a standalone switch. The originally-backup switch
(“prtlndB”) is also running the downgrade release. Both have redundancy
parameters configured but disabled. Both also have active licenses. They are
ready to join as a redundant pair.
Log into each of them, enter cfg-redundancy mode, and use the enable
command in that mode. For example:
Peer A
prtlndA# config
prtlndA(cfg)# redundancy
prtlndA(cfg‐redundancy)# enable
prtlndA(cfg‐redundancy)#
Peer B
prtlndB# config
prtlndB(cfg)# redundancy
prtlndB(cfg‐redundancy)# enable
08‐25 17:29:56 Peer switch 'prtlndA' is now online
prtlndB(cfg‐redundancy)# show redundancy
CLI Maintenance Guide
6 - 35
Chapter 6
Upgrading Software
Transitions
Node Switch/Quorum Disk Status Role Total Last (UTC)
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 prtlndA Up Active 1 14:46:03 08/29/2012
*2 prtlndB Up Backup Never ‐
QD 192.168.74.83 Up Quorum 1 14:44:06 08/29/2012
prtlndB(cfg‐redundancy)#
6 - 36
7
Metadata Utilities: nsck and sync
• Overview
• Showing the Progress of nsck and sync Jobs
• Showing Metadata
• Warning Signs for Metadata Inconsistencies
• Finding Metadata Inconsistencies
• Synchronizing Metadata with Actual Files
• Adding and Synchronizing Filer Subshares (CIFS)
• Rebuilding a Namespace
• De-Staging a Namespace’s Managed Volumes
• Migrating Metadata to a New Back-End Share
• Clearing All nsck Jobs
Overview
Overview
The Namespace-Check (nsck) and synchronization (sync) utilities
manipulate the metadata in managed volumes. Metadata is high-level
information such as physical-file locations on back-end filers,
modification-time stamps, and file sizes. The nsck utility can show a
volume’s metadata to reveal which back-end shares hold its files and
directories. If you suspect that the metadata is inconsistent with the
back-end files, you can use nsck to re-examine the filers and compare the
results with the metadata. Wherever nsck finds metadata inconsistencies,
you have the opportunity to correct them.
The nsck and sync utilities offer several options for working with metadata:
• nsck report shows the current state of metadata,
• sync finds and corrects metadata inconsistencies,
• nsck rebuild rebuilds an entire namespace by re-importing all of its
shares,
• nsck destage removes all metadata for a volume, share, or filer so that
you can directly access the filer(s), and
• nsck migrate moves a volume’s metadata from one back-end share to
another.
The nsck and sync utilities do not apply to direct volumes, which contain no
metadata. This chapter is relevant to managed volumes only.
CLI Maintenance Guide
7-3
Chapter 7
Metadata Utilities: nsck and sync
Showing the Progress of nsck and sync Jobs
Before you begin running nsck and sync jobs, it is helpful to know how to
monitor their progress. You can monitor the progress of any nsck or sync
job with the show nsck command:
show nsck
This shows a table with one row per job. The last column is Status. All nsck
reports go through two states in the Status column: Pending and Complete.
The nsck and sync jobs that verify and/or change metadata have
intermediate stages to indicate that they are in progress.
For example, the following jobs have all completed successfully:
bstnA(gbl)# show nsck
Op Id Op Type Namespace:Path Status
‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 report insur:/claims Complete
2 report wwmed:/acct Complete
3 report wwmed:/acct Complete
4 report wwmed:/acct/payable Complete
5 report wwmed:/acct Complete
6 report wwmed:/acct Complete
7 report wwmed:/acct/payable Complete
8 report wwmed:/acct Complete
9 report wwmed:/acct Complete
10 report wwmed:/acct Complete
11 sync wwmed:/acct/payable Complete
12 report medarcv:/lab_equipment Complete
13 report medarcv:/rcrds Complete
14 report medarcv:/test_results Complete
15 report medarcv:/lab_equipment Complete
16 report medarcv:/rcrds Complete
17 report medarcv:/test_results Complete
18 report medarcv:/lab_equipment Complete
19 report medarcv:/rcrds Complete
20 report medarcv:/test_results Complete
21 report medarcv:/lab_equipment Complete
22 report medarcv:/rcrds Complete
23 report medarcv:/test_results Complete
24 report medarcv:/lab_equipment Complete
25 report medarcv:/rcrds Complete
26 sync medarcv:/rcrds/sprains Complete
27 sync medarcv:/rcrds/ Complete
28 sync medarcv:/lab_equipment/acme Complete
29 sync medarcv:/lab_equipment/ Complete
30 report insur:/claims Complete
31 report insur:/claims Complete
32 report insur:/claims/tools Complete
33 report insur:/claims Complete
34 report insur:/claims Complete
35 report insur:/claims/tools Complete
36 report insur:/claims Complete
37 report insur:/claims Complete
bstnA(gbl)# ...
7-4
Showing the Progress of nsck and sync Jobs
Showing the nsck/sync Jobs for One Namespace
To view only the nsck and/or sync jobs for one namespace, add the
namespace clause to the end of the show nsck command:
show nsck namespace namespace
where namespace (1-30 characters) specifies the namespace.
For example, the following command shows the nsck and sync jobs for the
“wwmed” namespace:
bstnA(gbl)# show nsck namespace wwmed
Op Id Op Type Namespace:Path Status
‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2 report wwmed:/acct Complete
3 report wwmed:/acct Complete
4 report wwmed:/acct/payable Complete
5 report wwmed:/acct Complete
6 report wwmed:/acct Complete
7 report wwmed:/acct/payable Complete
8 report wwmed:/acct Complete
9 report wwmed:/acct Complete
10 report wwmed:/acct Complete
11 sync wwmed:/acct/payable Complete
bstnA(gbl)# ...
Showing One nsck/sync Job
Use the Op Id (from the output of the above commands) to focus the show
nsck command on a single nsck or sync job:
show nsck job‐id
where job-id specifies the ID for the nsck or sync job.
This shows additional detail for the report, such as the name of the report
and the switch where the report is kept (this is useful for redundant pairs).
For example, the following command shows the nsck job 1:
bstnA(gbl)# show nsck 1
Op Type: report
Op Id: 1
Report Name: insur_fgns_1._claims.rpt
Switch: bstnA
Namespace: insur
Path: /claims
Status: Complete
bstnA(gbl)# ...
Showing all nsck/sync Jobs
Use show nsck all to see details for all nsck and sync jobs:
show nsck all
For example:
CLI Maintenance Guide
7-5
Chapter 7
Metadata Utilities: nsck and sync
bstnA(gbl)# show nsck all
Op Type: report
Op Id: 1
Report Name: insur_fgns_1._claims.rpt
Switch: bstnA
Namespace: insur
Path: /claims
Status: Complete
Op Type: report
Op Id: 2
Report Name: inconsistencies.2.rpt
Switch: bstnA
Namespace: wwmed
...
bstnA(gbl)# ...
Showing all nsck/sync Reports
The show nsck command is focused on job status; if all nsck and sync jobs
are cleared from the database (as described below), no jobs appear in show
nsck. To see an up-to-date list of nsck or sync reports, use show reports
type:
show reports type {Dstg | Inc | MdO | MgMd | MdU | Rbld | Sync | SySh}
where
Dstg lists all metadata-inconsistencies reports,
Inc lists all metadata-inconsistencies reports,
MdO lists all metadata-only reports,
MgMd lists all metadata-migration reports,
MdU lists all metadata-upgrade reports, A metadata upgrade may
occur in the background after you install a new software release.
Rbld lists all rebuild reports,
Sync lists all sync reports, and
SySh lists all sync-share reports.
These report types are explained later in this chapter.
For example, the following output lists all sync reports:
bstnA# show reports type Sync
reports
Codes: Sync=Sync Files/Dirs
sync.1._acct.rpt Mar 20 01:06 1.4 k Sync DONE: 31 in 00:00:00
sync.2._rcrds.rpt Mar 20 01:07 1.8 k Sync DONE: 11 in 00:00:00
sync.3._rcrds.rpt Mar 20 01:07 1.9 k Sync DONE: 245 in 00:00:00
sync.4._lab_equipment.rpt Mar 20 01:07 1.5 k Sync DONE: 0 in 00:00:01
sync.5._lab_equipment.rpt Mar 20 01:07 2.0 k Sync DONE: 0 in 00:00:00
bstnA# ...
7-6
Showing the Progress of nsck and sync Jobs
Showing the Status of One Report
Use show reports status to show the one-line status for a particular report:
show reports status report‐name
where report-name (1-1024 characters) selects the report.
The output is a single status line for the report; it matches the line from the
show reports output.
For example, this command shows the status of the “sync.3.rcrds.rpt” report.
bstnA# show reports status sync.3._rcrds.rpt
reports
Codes: Sync=Sync Files/Dirs
sync.3._rcrds.rpt 04/23 02:11 2.0 kB Sync DONE: 287 in 00:00:00
bstnA# ...
CLI Maintenance Guide
7-7
Chapter 7
Metadata Utilities: nsck and sync
Showing Metadata
You can use the nsck report metadata-only command to show the physical
locations of all files and directories in a namespace’s managed volumes. A
file’s physical location is its directory path including the IP address of the
filer where it resides; for example, 192.168.25.21:/usr/local/bin. You can
use this command to see the before-and-after effects of namespace policy on
the actual location of your files.
From priv-exec mode, use the nsck report metadata-only command to show
physical file locations for a namespace:
nsck namespace report metadata‐only [path] [norecurse]
where:
namespace (1-30 characters) specifies a namespace on which to
report. Use the show namespace command for a list of configured
namespaces.
path (optional, 1-256 characters) narrows the scope of the report to
a specific virtual path in the namespace (for example, ‘/eng/share’).
This must be a managed volume or a path within a managed
volume.
norecurse (optional) specifies to not recurse into subdirectories
during the report.
Note
You can run only one nsck job (report or rebuild) at a time on a given
managed volume. Use show nsck to monitor the progress of nsck jobs; see
Showing the Progress of nsck and sync Jobs, on page 7-4.
The report goes to a file, “metadata_only.id.rpt.” The id is a unique number
for every nsck report. The CLI shows the report name after you invoke the
command. Use show reports to see the file listing; use show, tail, or grep to
read the file. To save the report off to an external FTP site, use the copy ...
ftp command from priv-exec mode.
This report has five major sections:
1. The start time, namespace, volume, and path for the report.
2. A table of namespace shares that were examined, along with the IP
of the back-end filer and the share name at the filer.
3. A legend of keys for the next table.
4. A table of files and directories in the metadata. For each
file/directory, the table shows three fields:
a) Type is a list of file types (shown as keys from the legend above),
b) Share is the filer-share name with the file, and
c) Path is the exact path of the file on the share, relative to the
share’s root.
7-8
Showing Metadata
5. A summary list with various totals.
For example, the following command sequence exits to priv-exec mode,
dumps all physical file locations for the ‘wwmed’ namespace, and reviews
the report:
bstnA(gbl)# end
bstnA# nsck wwmed report metadata‐only
Scheduling report: metadata_only.5.rpt on switch bstnA
bstnA# show reports metadata_only.5.rpt
**** Metadata‐Only Report: Started at 04/23/2012 02:08:59 ‐0400 ****
**** Software Version: 6.02.000.14358 (Apr 18 2012 20:09:15) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: wwmed
**** Volume: /acct
**** Path: /acct
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[budget ] 192.168.25.19:/exports/budget
[bills ] 192.168.25.25:/work1/accting
[bills2 ] 192.168.25.23:/exports/acct2
[it5 ] 192.168.25.24:/lhome/it5
**** Legend:
**** FL = File: The reported entry is a file.
**** DR = Directory: The reported entry is a directory.
**** SL = Symlink: The reported entry is a symbolic link.
**** LN = Link: The reported entry has a link count greater than one.
**** NL = No Lock: Was unable to lock parent directory during report.
**** CC = NFS case‐blind name collision.
**** IC = Name contains invalid CIFS characters.
**** FN = Name may conflict with a filer‐generated name.
**** SP = A persistent split is registered in the metadata, due to a FGN.
**** NF = Name is only accessible to NFS clients.
**** IA = Inconsistent attributes between this directory's master and stripes (recorded).
**** IS = Inconsistent attributes on this specific directory stripe (recorded).
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ DR ] [budget ] /
[FL ] [budget ] /layer3.fm.lck
[ DR ] [bills2 ] /planner
[FL ] [bills2 ] /layer2.fm.lck
[FL ] [bills2 ] /cliOperator.book
[ DR ] [budget ] /production
[FL ] [bills2 ] /finance_sites.html
[FL ] [bills ] /shellCmds_winXP.fm
[FL ] [budget ] /sampleNet.html
...
[FL ] [budget ] /receipts/giftShop/sep2006.csv
[FL ] [bills2 ] /receipts/giftShop/xmas2009.csv
[FL ] [bills2 ] /receipts/giftShop/aug2009.csv
**** Total Files: 3,994
**** Total Directories: 439
**** Total Hard Links (nlink>1): 0
**** Total Symlinks: 9
CLI Maintenance Guide
7-9
Chapter 7
Metadata Utilities: nsck and sync
**** Total Locking Errors: 0
**** Total items: 4,433
**** Elapsed time: 00:00:00
**** Metadata‐Only Report: DONE at 04/23/2012 02:08:59 ‐0400 ****
bstnA# ...
Focusing on One Share
You can generate a report that focuses on one managed-volume share. Use
the optional share clause to report the metadata for a single share:
nsck namespace report metadata‐only [path] share share‐name [norecurse]
where
namespace, report metadata-only, path, and norecurse are all
explained above,
share share-name (optional; 1-64 characters) specifies the
namespace share.
If the share does not hold any of the files in the path, the report is empty.
For example, the following command sequence dumps the metadata for the
“bills” share in “wwmed:”
bstnA(gbl)# end
bstnA# nsck wwmed report metadata‐only share bills
Scheduling report: metadata_only.20.rpt on switch bstnA
bstnA# ...
Sending the Output to a Different File
Use the optional outputfile clause to send the nsck results to a file other than
the default, “metadata_only.n.rpt:”
nsck namespace report metadata‐only [path] [share share‐name] [norecurse] outputfile file‐name
where
name, report metadata-only, path, share share-name, and
norecurse are all explained above, and
outputfile file-name (optional; 1-256 characters) specifies a prefix
for the file name. Use show reports to see the file listing; use show,
tail, or grep to read the file. If the file-name already exists, the CLI
prompts for confirmation.
For example, the following command sequence dumps a share’s file
locations to a file named “wwmed_bills.8.rpt:”
bstnA(gbl)# end
bstnA# nsck wwmed report metadata‐only share bills outputfile wwmed_bills
Scheduling report: wwmed_bills.8.rpt on switch bstnA
bstnA# ...
7 - 10
Showing Metadata
Canceling the Report
This report operation can require a long time and heavy CPU resources if
run on a very-large namespace. You can use the cancel nsck report
command to cancel a long-running nsck report:
cancel nsck report job‐id
where job-id (1-2,147,483,647) identifies the nsck-report job to cancel.
This ID appears in the output of show nsck.
The CLI prompts for confirmation before canceling the report job. Enter yes
to proceed.
For example, the following command sequence stops job 19, which was still
in progress:
bstnA(gbl)# show nsck
show nsck
Op Id Op Type Namespace:Path Status
‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 report insur:/claims Complete
2 report wwmed:/acct Complete
3 report wwmed:/acct Complete
4 report wwmed:/acct/payable Complete
5 report wwmed:/acct Complete
6 report wwmed:/acct Complete
7 report wwmed:/acct/payable Complete
8 report wwmed:/acct Complete
9 report wwmed:/acct Complete
10 report wwmed:/acct Complete
11 sync wwmed:/acct/payable Complete
12 report medarcv:/lab_equipment Complete
13 report medarcv:/rcrds Complete
14 report medarcv:/lab_equipment Complete
15 report medarcv:/test_results Complete
16 report medarcv:/rcrds Complete
17 report medarcv:/lab_equipment Complete
18 report medarcv:/test_results Complete
19 report medarcv:/rcrds Report in progress
bstnA(gbl)# end
bstnA# cancel nsck report 19
Cancel the nsck metadata‐only report operation 'metadata_only.18.rpt'? [yes/no] yes
bstnA# ...
CLI Maintenance Guide
7 - 11
Chapter 7
Metadata Utilities: nsck and sync
Showing Directory Structure
You can display a summary of a managed volume's directory structure
without having to run an actual metadata report, using the CLI command
nsck report dir-structure. This generates a directory structure report that
you can view later.
The command syntax is:
nsck name report dir‐structure [path] [norecurse] [summary] [outputfile outputfilename]
where:
name specifies the namespace for which to run the directory
structure report.
path specifies a volume or volume/path on which to report.
norecurse indicates that the report will not explore subdirectories.
summary indicates that the report will not list the details of the
individual subdirectories it encounters.
outputfile specifies the name of the file to which the report output
is written. The "outputfile" option is a report prefix that has the
".rpt" extension appended to it at a minimum. If no path is
specified, the file name is outputfile.volume.rpt.
For example:
nsck wwmed report dir‐structure path outputfile wwmed_dirstruct
generates a directory structure report for the namespace "wwmed" that is
written to the file named "wwmed_dirstruct". The report recurses into
subdirectories that it encounters, and is a full report, not a summary.
Use the show reports type ds CLI command to list the directory structure
reports that have been generated already.
If this command is executed for a namespace without specifying a path, one
report is generated per volume in the namespace. (This includes direct
volumes.)
Example
This example shows the results of the command, nsck insur report
dir-structure:
bstnA# show reports dir_structure.43.rpt
**** Directory Structure Report: Started at 04/25/2012 12:01:25 ‐0400 ****
**** Software Version: 6.02.000.14360 (Apr 23 2012 20:09:34) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: insur
**** Volume: /claims
**** Path: /claims
7 - 12
Showing Directory Structure
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[shr1‐old ] 192.168.25.21 NFS:/vol/vol2/insurance, CIFS:insurance
[shr1‐next ] 192.168.25.51NFS:/root_vdm_4/patient_records, CIFS:patient_records
**** Legend:
**** NL = No Lock: Was unable to lock parent directory during report.
Flag Dirs Files Links Symlinks Path
‐‐‐‐ ‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ ] 15 8 0 0 /claims/
[ ] 0 0 0 0 /claims/Claims:2001/
[ ] 0 0 0 0 /claims/claims:2005/
[ ] 1 24 0 2 /claims/common/
[ ] 0 4 0 0 /claims/draft_proposals./
[ ] 0 50 0 0 /claims/images/
[ ] 0 0 0 0 /claims/POLICI~2/
[ ] 2 7 0 1 /claims/specs/
[ ] 2 9 0 0 /claims/stats/
[ ] 0 8 0 0 /claims/tools/
[ ] 0 0 0 0 /claims/Tools/
[ ] 0 0 0 0 /claims/y2kclaims/
[ ] 0 0 0 0 /claims/dir0134(U+0134)_shr1‐old‐12/
[ ] 0 1 0 0 /claims/common/eastLab/
[ ] 0 22 0 0 /claims/specs/common/
[ ] 0 3 0 0 /claims/stats/in_home:2005/
[ ] 1 1 0 1 /claims/specs/protos/
[ ] 0 5 0 0 /claims/stats/otj_latest/
[ ] 0 0 0 0 /claims/specs/protos/accepted/
[ ] 0 9 0 0 /claims/Y2KCLA~1/
[ ] 0 0 0 0 /claims/Y2KCLA~4/
Directory Structure Summary:
Maximum Entries in a directory: 50
Maximum sub‐directories in a directory: 15
Maximum Files in a directory: 50
Maximum Links in a directory: 0
Maximum Symlinks in a directory: 2
Average Entries in a directory: 8
Average Files in a directory: 7
**** Total Files: 151
**** Total Directories: 21
**** Total Leaf Directories: 16
**** Total Interior Directories: 5
**** Total Hard Links (nlink>1): 0
**** Total Symlinks: 4
**** Total items: 172
**** Elapsed time: 00:00:00
**** Directory Structure Report: DONE at 04/25/2012 12:01:25 ‐0400 ****
CLI Maintenance Guide
7 - 13
Chapter 7
Metadata Utilities: nsck and sync
Cancelling the Report
Directory structure reports can be cancelled by executing the command
cancel nsck report id, where id specifies the nsck job to be cancelled. nsck
jobs have IDs in the range of 1 to 2,147,483,647.
7 - 14
Warning Signs for Metadata Inconsistencies
Warning Signs for Metadata Inconsistencies
If clients get front-end-service (NFS or CIFS) failures for a particular
managed volume, the volume’s metadata might be inconsistent. For
example, clients might see files disappearing (“file not found” and/or “stale
NFS filehandle” errors) or new files that appear unexpectedly. Inconsistent
metadata is the result of changes happening directly on a filer, not through
its managed volume. Best practices dictate that you should avoid this
situation at all times. However, some situations make this impossible to
prevent:
• On reboot recovery, some filers replace files that were deleted shortly
before the reboot.
• A filer-integrated Anti-Virus application may rename, remove, or create
files on the filer itself.
• Some customers prefer to perform restore operations directly on their
back-end filers.
Whenever a managed-volume client tries to access a file that has been
removed by one of the above operations, the client system reports an
internal error. For CIFS operations, messages appear in the syslog (labeled
UNXFINDNONE, UNXNOPATH, UNXOPENTYPE and/or
UNXCRETYPE.), and the namespace software sends an SNMP trap
(vcifsNotfound or vcifsTypeMismatch). Use grep to search the syslog for a
string. (The syslog is rotated regularly; use show logs for a complete list of
all log files, including backups.)
To find the exact scope of metadata inconsistency, use the nsck report
inconsistencies command described below.
CLI Maintenance Guide
7 - 15
Chapter 7
Metadata Utilities: nsck and sync
Finding Metadata Inconsistencies
The nsck report inconsistencies utility detects metadata inconsistencies and
produces a report. Metadata inconsistencies occur when a client is
connected directly to a back-end share and performs writes or deletes
through that direct connection. Without the ARX in the data path, the switch
has no knowledge of the changes and cannot update its metadata.
servers
invalid
client
ARX
valid clients
A local process on the filer, such as anti-virus software, can cause an
inconsistency by removing or renaming a file.
You can use the nsck report inconsistencies to determine whether to run
sync files or a full nsck rebuild on a namespace, or to confirm that there are
no inconsistencies at all.
From priv-exec mode, use the nsck report inconsistencies command to
check the current namespace’s managed volumes for metadata
inconsistency:
nsck name report inconsistencies [path] [share share‐name] [norecurse] [nofilehandles] [outputfile outputfile]
where:
name (1-30 characters) is the namespace on which to report. Use
the show namespace command for a list of configured
namespaces.
path (optional, 1-256 characters) narrows the scope of the report to
a specific virtual path in the namespace (for example,
‘/home/jrandom’). This must be a managed volume, or a path
within a managed volume.
share share-name (optional, 1-64 characters) narrows the scope
further, to a single namespace share. This is the share’s name in the
namespace, not on the filer.
7 - 16
Finding Metadata Inconsistencies
norecurse (optional) specifies to not recurse into subdirectories
during the report.
nofilehandles (optional) specifies to not validate filehandles during
a report.
outputfile outputfile (optional, 1-256 characters) specifies a prefix
for a customized file name (for example,
‘jrandom_inconsistencies’), as opposed to the default. Use the
show reports command to display the file in the maintenance
directory.
You can run one nsck job at a time on a given volume. Use show nsck to
monitor the progress of nsck jobs; see Showing the Progress of nsck and
sync Jobs, on page 7-4.
The CLI shows the report name after you invoke the command. Use show
reports for a full list of nsck reports, and use show, tail, or grep to view one
report. The report contains the following information:
1. The start time, namespace, volume, and path for the report.
2. A table of shares that were examined, along with the IP of the
back-end filer and the share name at the filer.
3. A legend of keys for various types of metadata inconsistency. These
keys are used in the next table.
4. A table of files with metadata inconsistencies. For each file, the
table shows
a) Type - a list of the file’s inconsistencies (shown as keys from the
legend above),
b) Share - the name of the ARX share with the inconsistent file, and
c) Path - the exact path of the file on the share, relative to the
share’s root.
5. A summary list with various totals.
For example, the following command sequence finds a missing file in the
medarcv namespace (highlighted in bold text):
bstnA(gbl)# end
bstnA# nsck medarcv report inconsistencies norecurse
Scheduling report: inconsistencies.15.rpt on switch bstnA
bstnA# show reports inconsistencies.15.rpt
**** Inconsistencies Report: Started at 04/25/2012 11:59:39 ‐0400 ****
**** Software Version: 6.02.000.14360 (Apr 23 2012 20:09:34) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: medarcv
**** Volume: /rcrds
**** Path: /rcrds
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[rx ] 192.168.25.29:prescriptions
[charts ] 192.168.25.20:histories
CLI Maintenance Guide
7 - 17
Chapter 7
Metadata Utilities: nsck and sync
[bulk ] 192.168.25.27:bulkstorage
**** Legend:
**** LF = File exists in the metadata, but is missing from the physical filer.
**** LD = Directory exists in the metadata, but is missing from the physical filer.
**** FF = File exists on the physical filer, but is missing from the metadata.
**** FD = Directory exists on the physical filer, but is missing from the metadata.
**** LL = File is a symlink in the metadata, but is a regular file on the filer.
**** FL = File is a symlink on the filer, but is a regular file in the metadata.
**** IF = Filehandles in the metadata do not match the filehandles on the physical filer.
**** MF = The file is currently being migrated.
**** NL = Unable to lock parent directory during report.
**** FE = Error contacting filer during report.
**** FO = Filer Offline: The filer is offline or disabled.
**** F8 = A file name matches a CIFS alternate "8.3" name on another share.
**** D8 = A directory name matches a CIFS alternate "8.3" name; its contents will be skipped.
**** DC = A client has the file or directory open for delete‐on‐close, but the filer has already deleted it.
**** SD = Striped leaf directory found on filer, expected on other shares.
**** SL = File is a symlink.
**** UT = Name contains characters that are invalid UTF‐8; must solve issue directly on the filer
**** IS = Inconsistent attributes on one of this directory's stripes (discovered)
**** MI = Attributes are consistent, metadata marked as inconsistent
**** SI = Attributes are inconsistent, metadata not marked as inconsistent
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[LF ] [charts ] /copyRandomx.exe
[ F8 ] [charts ] /KMO_ME~1.DAT ‐> kmo_medical_record.dat
[ D8 ] [charts ] /RECORD~1/ ‐> records_predating_y2k
**** Total Found Items: 0
**** Total Lost Items: 1
**** Total Invalid Filehandles: 0
**** Total Migrating Files: 0
**** Total Deleted Before Close: 0
**** Total Locking Errors: 0
**** Total Filer Errors: 0
**** Total 8.3 Errors: 2
**** Total Found Stripes: 0
**** Total Inconsistent Attrs: 0
**** Total processed: 218
**** Elapsed time: 00:00:00
**** Inconsistencies Report: DONE at 04/25/2012 11:59:39 ‐0400 ****
bstnA# ...
Focusing on Multi-Protocol Issues
A volume in a multi-protocol (CIFS and NFS) namespace may have files
whose names are inconsistent between CIFS and NFS. Some characters are
legal in NFS file names but unsupported in CIFS names, just as CIFS has
some naming conventions that NFS cannot always follow. (These issues are
discussed extensively in a later chapter about troubleshooting managed
7 - 18
Finding Metadata Inconsistencies
volumes.) To create a report that shows all multi-protocol naming issues in a
volume, add the multi-protocol flag to the nsck ... report inconsistencies
command:
nsck name report inconsistencies [path] [share share‐name] [norecurse] [nofilehandles] [multi‐protocol] [outputfile outputfile]
where:
multi-protocol (optional) focuses the report on NFS/CIFS naming
issues, and
the remaining options were described above.
For example, the following command sequence generates an inconsistencies
report for the “insur~/claims” volume that focuses on multi-protocol issues,
then shows the report:
bstnA(gbl)# end
bstnA# nsck insur report inconsistencies multi‐protocol outputfile insur_fgns
Scheduling report: insur_fgns._claims.rpt on switch bstnA
bstnA# show reports insur_fgns._claims.rpt
**** Inconsistencies Report: Started at 04/25/2012 12:01:43 ‐0400 ****
**** Software Version: 6.02.000.14360 (Apr 23 2012 20:09:34) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: insur
**** Volume: /claims
**** Path: /claims
**** multiprotocol flag specified
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[shr1‐old ] 192.168.25.21 NFS:/vol/vol2/insurance, CIFS:insurance
[shr1‐next ] 192.168.25.51NFS:/root_vdm_4/patient_records, CIFS:patient_records
**** Legend:
**** LF = File exists in the metadata, but is missing from the physical filer.
**** LD = Directory exists in the metadata, but is missing from the physical filer.
**** FF = File exists on the physical filer, but is missing from the metadata.
**** FD = Directory exists on the physical filer, but is missing from the metadata.
**** LL = File is a symlink in the metadata, but is a regular file on the filer.
**** FL = File is a symlink on the filer, but is a regular file in the metadata.
**** IF = Filehandles in the metadata do not match the filehandles on the physical filer.
**** MF = The file is currently being migrated.
**** NL = Unable to lock parent directory during report.
**** FE = Error contacting filer during report.
**** FO = Filer Offline: The filer is offline or disabled.
**** F8 = A file name matches a CIFS alternate "8.3" name on another share.
**** D8 = A directory name matches a CIFS alternate "8.3" name; its contents will be skipped.
**** DC = A client has the file or directory open for delete‐on‐close, but the filer has already deleted it.
**** SD = Striped leaf directory found on filer, expected on other shares.
**** SL = File is a symlink.
**** UT = Name contains characters that are invalid UTF‐8; must solve issue directly on the filer
**** IS = Inconsistent attributes on one of this directory's stripes (discovered)
**** MI = Attributes are consistent, metadata marked as inconsistent
**** SI = Attributes are inconsistent, metadata not marked as inconsistent
****
**** Multi‐Protocol Only:
**** NF = Name is accessible only to NFS clients.
**** NI = Name does not exist via both NFS and CIFS.
CLI Maintenance Guide
7 - 19
Chapter 7
Metadata Utilities: nsck and sync
**** CC = Case‐blind name collision.
**** IC = CIFS invalid characters found in NFS name.
**** FN = A portion of the name contains a filer‐generated pattern.
**** NM = CIFS name has characters that are not mappable to the NFS encoding.
**** SP = A NFS name in the path's ancestry will prevent CIFS access.
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ NF CC ] [shr1‐old ] /INDEX.html
[ NF CC ] [shr1‐old ] /index.html
[ NF CC ] [shr1‐old ] /Tools
[ NF CC ] [shr1‐old ] /tools
[ NF IC ] [shr1‐old ] /Claims:2001
[ NF IC ] [shr1‐old ] /claims:2005
[ NF IC ] [shr1‐old ] /draft_proposals.
[ F8 ] [shr1‐old ] /OVERDU~1.DOC ‐> overdueclaimsmemo.doc
[ SP] [shr1‐old ] /draft_proposals./FY06challenges.ppt
[ SP] [shr1‐old ] /draft_proposals./claim2389_rebut2.doc
[ SP] [shr1‐old ] /draft_proposals./FY2007propB.ppt
[ SP] [shr1‐old ] /draft_proposals./claim2389_rebut1.doc
[ NF IC ] [shr1‐old ] /images/FRU replace wrongway.tif
[ NF IC ] [shr1‐old ] /images/:KJUK000
[ NI NM ] [shr1‐old ] /images/file012bÄ«/ (Characters: U+012b)
[ NF CC ] [shr1‐old ] /stats/piechart.ppt
[ NF CC ] [shr1‐old ] /stats/PieChart.ppt
[ NF IC ] [shr1‐old ] /stats/on_the_job:2004.cnv
[ NF IC ] [shr1‐old ] /stats/on_the_job:2003.cnv
[ NF IC ] [shr1‐old ] /stats/in_home:2005
[ SP] [shr1‐old ] /tools/extractCdDocs.pl
[ SP] [shr1‐old ] /tools/cleanBU.csh
[ SP] [shr1‐old ] /tools/checkinAll.pl
[ SP] [shr1‐old ] /tools/docSet.pl
[ SP] [shr1‐old ] /tools/updateCvs.csh
[ SP] [shr1‐old ] /tools/books.xml
[ SP] [shr1‐old ] /tools/blowAway.pl
[ SP] [shr1‐old ] /tools/makeCd.pl
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:11‐21yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:>21yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:<10yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:>21yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:<10yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:11‐21yrs.csv
[ SP] [shr1‐old ] /stats/in_home:2005/age:<10yrs.csv
[ SP] [shr1‐old ] /stats/in_home:2005/age:>21yrs.csv
[ SP] [shr1‐old ] /stats/in_home:2005/age:11‐21yrs.csv
[ D8 ] [shr1‐old ] /Y2KCLA~1/ ‐> y2kclaims
**** Total Found Items: 0
**** Total Lost Items: 0
**** Total Invalid Filehandles: 0
**** Total Migrating Files: 0
**** Total Deleted Before Close: 0
**** Total Locking Errors: 0
**** Total Filer Errors: 0
**** Total 8.3 Errors: 2
**** Total Found Stripes: 0
**** Total Inconsistent Attrs: 0
**** Total processed: 171
**** Elapsed time: 00:00:00
**** Inconsistencies Report: DONE at 04/25/2012 12:01:43 ‐0400 ****
bstnA# ...
7 - 20
Finding Metadata Inconsistencies
Canceling the Report
This report operation can require a long time and heavy CPU resources if
run on a very-large namespace. As with a metadata-only report, you can use
the cancel nsck report command to cancel a long-running inconsistencies
report:
cancel nsck report job‐id
where job-id (1-2,147,483,647) identifies the nsck-report job to cancel.
This ID appears in the output of show nsck.
The CLI prompts for confirmation before canceling the report job. Enter yes
to proceed.
For example, the following command sequence stops job 30, an
inconsistencies report that was still in progress:
bstnA(gbl)# show nsck
show nsck
Op Id Op Type Namespace:Path Status
‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 report insur:/claims Complete
2 report wwmed:/acct Complete
3 report wwmed:/acct Complete
4 report wwmed:/acct/payable Complete
5 report wwmed:/acct Complete
6 report wwmed:/acct Complete
...
26 sync medarcv:/rcrds/sprains Complete
27 sync medarcv:/rcrds/ Complete
28 sync medarcv:/lab_equipment/acme Complete
29 sync medarcv:/lab_equipment/ Complete
30 report insur:/claims Report in progress
bstnA(gbl)# end
bstnA# cancel nsck report 30
Cancel the nsck inconsistencies report operation 'inconsistencies.25.rpt'? [yes/no] yes
bstnA# ...
CLI Maintenance Guide
7 - 21
Chapter 7
Metadata Utilities: nsck and sync
Synchronizing Metadata with Actual Files
An earlier example showed a file, copyRandom.exe, that is recorded in
volume metadata but is missing from its back-end filer. You can use the
sync utility to re-synchronize the metadata with the actual contents of the
filers. You can configure a CIFS volume to automatically sync itself
whenever a client encounters a metadata error (see Automatically
Synchronizing Metadata (CIFS), on page 9-10 of the ARX® CLI
Storage-Management Guide), or you can run the sync operation manually as
described here. From priv-exec mode, use the sync files command to
synchronize metadata for files:
sync files namespace volume vol‐path path path [recurse] [rename‐files]
where:
namespace (1-30 characters) is the namespace to sync. Use the
show namespace command for a list of configured namespaces
(see Listing All Namespaces, on page 7-4 of the ARX® CLI
Storage-Management Guide).
vol-path (1-1024 characters) chooses a specific managed volume in
the namespace. Use forward slashes (/) in the path, even for CIFS
volumes.
path (1-1024 characters) selects a virtual path in the volume (for
example, ‘/’ or ‘/home/jrandom’). You can shorten the time
required for the sync with this option; use the
metadata-inconsistencies report to find the best path.
You can enter the optional recurse and rename-files flags in any
order:
•
recurse (optional) causes the sync operation to descend into
subdirectories.
•
rename-files (optional) allows the sync process to rename any
newly-discovered file that has the same name as a
previously-imported file. (This command generates a report,
described below, that identifies renamed files.)
In multi-protocol (NFS and CIFS) volumes, this also synchronizes the
metadata with the current state of filer-generated names (FGNs, such as
“FILE~2.DOC”) on its back-end filers. This is discussed in detail in a later
chapter about troubleshooting managed volumes.
As with nsck jobs, every sync operation produces a report as it runs. The
CLI shows the report name after you invoke the command. Use show
reports for a full list of sync reports, and use show, tail, or grep to view one
report. The report is similar to the metadata-inconsistencies report,
described above. This report adds some additional Type keys to show which
files were synchronized, were renamed, or encountered synchronization
issues.
For example, this command sequence re-synchronizes the medarcv~/rcrds
volume and then shows the report:
7 - 22
Synchronizing Metadata with Actual Files
bstnA(gbl)# end
bstnA# sync files medarcv volume /rcrds path / recurse rename‐files
Scheduling sync files operation on switch bstnA, report name: sync.3._rcrds.rpt
bstnA# show reports sync.3._rcrds.rpt
**** Sync Report: Started at 04/25/2012 12:00:38 ‐0400 ****
**** Software Version: 6.02.000.14360 (Apr 23 2012 20:09:34) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: medarcv
**** Volume: /rcrds
**** Path: /
**** Options: recurse rename‐files
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[rx ] 192.168.25.29:prescriptions
[charts ] 192.168.25.20:histories
[bulk ] 192.168.25.27:bulkstorage
**** Legend:
****
**** Actions:
**** SY = File metadata has been synchronized.
**** LF = Lost File, File exists in the metadata, but not on filer.
**** FF = Found File, File exists on filer, but not in the metadata.
**** LL = Lost Symlink, File is a symlink in the metadata, but not on filer.
**** FL = Found Symlink, File is a symlink on the filer, but not in the metadata.
**** IF = Invalid File Handle, Metadata/Filer file handle mismatch.
**** CR = File collided with existing filename, and was renamed.
**** NC = File or directory is now accessible to both NFS and CIFS.
**** SD = Striped directory found on filer; registered in metadata.
**** SC = Directory stripe inconsistency has been cleared.
**** SI = Directory stripe is now inconsistent due to attempted synchronization.
****
**** Warnings:
**** CC = NFS case‐blind name collision, FGN may result under CIFS.
**** IC = Name contains invalid characters for CIFS, FGN will result under CIFS.
**** NI = Name does not exist via both NFS and CIFS.
**** UN = Name contains unmappable unicode characters, FGN will result under NFS.
**** U8 = Name contains invalid UTF‐8 characters, not imported.
**** CD = CIFS case blind name collision, directory ignored.
**** RV = Reserved name encountered on filer, not imported.
**** NF = Name is only accessible using NFS.
**** SL = File is a symlink.
****
**** Errors:
**** TO = Operation timed out: An operation to the filer timed out.
**** LK = Failed to acquire Lock.
**** FE = Encountered filer error during sync.
**** CF = File collided with existing filename.
**** CN = CIFS case blind name collision, file renamed.
**** CZ = CIFS case blind name collision, no rename, use rename‐files.
**** FD = Found Directory, Directory exists on filer, but not in the metadata.
**** NE = Directory not empty
Synchronization Results:
===============================================================================
Type Share Object
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
CLI Maintenance Guide
7 - 23
Chapter 7
Metadata Utilities: nsck and sync
[SY LF ] [charts ] /copyRandomx.exe
===============================================================================
Total Found Items: 0
Total Lost Items: 1
Total Invalid Filehandles: 0
File Name Collisions: 0
File Collision Renames: 0
Total Migrations Aborted: 0
Total Items Synchronized: 1
Directories completely processed: 33
Total Directories: 33
CIFS Case Blind Collision Renames: 0
**** Total processed: 284
**** Elapsed time: 00:00:01
**** Sync Report: DONE at 04/25/2012 12:00:39 ‐0400 ****
bstnA# ...
Synchronizing with Actual Directories
Some installations require new directories that cannot be configured through
the client interfaces. These directories have features that can only be added
through an administrative interface on the back-end filer itself, such as disk
quotas. If such a directory is created behind a managed volume, you can use
the sync utility to add it to the metadata. This can only function for empty
directories, and for directories that are only on a single share behind the
managed volume. From priv-exec mode, use the sync directories command
to search a managed-volume directory for any new, unrecorded
subdirectories:
sync directories namespace volume vol‐path path path
where:
namespace (1-30 characters) is the namespace to sync. Use the
show namespace command for a list of configured namespaces
(see Listing All Namespaces, on page 7-4 of the ARX® CLI
Storage-Management Guide).
vol-path (1-1024 characters) chooses a specific managed volume in
the namespace. Use forward slashes (/) in the path, even for CIFS
volumes.
path (1-1024 characters) selects a virtual path in the volume (for
example, ‘/’ or ‘/home/jrandom’). The sync utility searches for new
directories under this path; it only searches this directory, and does
not descend into any known or discovered subdirectories.
Like the nsck and sync-files operations, this generates a report as it runs.
The report name appears after you issue the command.
For example, this command sequence synchronizes the root directory in the
medarcv~/lab_equipment volume and then shows the report:
bstnA(gbl)# end
7 - 24
Synchronizing Metadata with Actual Files
bstnA# sync directories medarcv volume /lab_equipment path /
Scheduling sync directories operation on switch bstnA, report name: sync.5._lab_equipment.rpt
bstnA# show reports sync.5._lab_equipment.rpt
**** Sync Report: Started at Wed Feb 24 01:58:07 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: medarcv
**** Volume: /lab_equipment
**** Path: /
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[equip ] 192.168.25.49:equipment
[leased ] 192.168.25.49:for_lease
[backlots ] 192.168.25.27:backlot_records
[scanners ] 192.168.25.71:xraysScanners
**** Legend:
****
**** Actions:
**** SY = File metadata has been synchronized.
**** LF = Lost File, File exists in the metadata, but not on filer.
**** FF = Found File, File exists on filer, but not in the metadata.
**** LL = Lost Symlink, File is a symlink in the metadata, but not on filer.
**** FL = Found Symlink, File is a symlink on the filer, but not in the metadata.
**** IF = Invalid File Handle, Metadata/Filer file handle mismatch.
**** CR = File collided with existing filename, and was renamed.
**** NC = File or directory is now accessible to both NFS and CIFS.
**** SD = Striped directory found on filer; registered in metadata.
****
**** Warnings:
**** CC = NFS case‐blind name collision, FGN may result under CIFS.
**** IC = Name contains invalid characters for CIFS, FGN will result under CIFS.
**** NI = Name does not exist via both NFS and CIFS.
**** UN = Name contains unmappable unicode characters, FGN will result under NFS.
**** U8 = Name contains invalid UTF‐8 characters, not imported.
**** CD = CIFS case blind name collision, directory ignored.
**** RV = Reserved name encountered on filer, not imported.
**** NF = Name is only accessible using NFS.
**** SL = File is a symlink.
****
**** Errors:
**** TO = Operation timed out: An operation to the filer timed out.
**** LK = Failed to acquire Lock.
**** FE = Encountered filer error during sync.
**** CF = File collided with existing filename.
**** CN = CIFS case blind name collision, file renamed.
**** CZ = CIFS case blind name collision, no rename, use rename‐files.
**** FD = Found Directory, Directory exists on filer, but not in the metadata.
**** NE = Directory not empty
Synchronization Results:
===============================================================================
Type Share Object
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[SY FD ] [leased ] /siemans
===============================================================================
CLI Maintenance Guide
7 - 25
Chapter 7
Metadata Utilities: nsck and sync
Total Found Items: 1
Total Lost Items: 0
Total Invalid Filehandles: 0
File Name Collisions: 0
File Collision Renames: 0
Total Migrations Aborted: 0
Total Items Synchronized: 1
Directories completely processed: 1
Total Directories: 1
CIFS Case Blind Collisions: 0
Non‐Empty Directories: 0
**** Total processed: 0
**** Elapsed time: 00:00:00
**** Sync Report: DONE at Wed Feb 24 01:58:07 2010 ****
bstnA# ...
Synchronizing Metadata in a Single Share
If the metadata inconsistencies are limited to a single, known share, you can
focus the sync process on the affected share. A narrow focus leads to shorter
sync times; you can use the metadata-inconsistencies report (described
above) to determine the share(s) with metadata inconsistencies.
To focus on one share, add the share option after the path:
sync files namespace volume vol‐path path path share share‐name [recurse] [rename‐files]
or, for directories,
sync directories namespace volume vol‐path path path share share‐name
where:
share-name (1-64 characters) identifies the share to sync. This is
the share’s name in the namespace, not on the filer.
The remaining arguments and flags are explained above.
For example, this command sequence syncs files in a single share,
“wwmed~/acct~bills.” It calls for a recursive sync, and it allows renaming
of newly-discovered files that introduce collisions:
bstnA(gbl)# end
bstnA# sync files wwmed volume /acct path /payable share bills recurse rename‐files
Scheduling sync files operation on switch bstnA, report name: sync.1._acct.rpt
bstnA# ...
Synchronization Occurs in Share-Priority Order
Whenever multiple shares are involved in a synchronization, the sync
process scans the shares according to their import priority. This is important
for any discovered files that collide with each other; the share with the
higher priority wins the file conflict, and the other share’s file must be
renamed. It is also important for colliding directories; the higher priority
share gets the master instance of the directory and the other share gets a
7 - 26
Synchronizing Metadata with Actual Files
stripe. The master instance controls the attributes of the directory (such as
permissions and named streams), and gets all newly-created files by default.
Tiered volumes use import priority to differentiate their Tier-1 shares from
the rest.
Refer to Setting the Share’s Priority (for Tiering), on page 9-36 of the
ARX® CLI Storage-Management Guide for more information on setting the
import priority for a volume’s shares.
Showing the Progress of All Sync Operations
A sync operation occurs in the background, similar to an nsck run. To see
the high-level status of all sync operations, use the show sync command:
show sync {files | directories}
For example, this shows all sync-files operations:
bstnA(gbl)# show sync files
Namespace: wwmed
Volume: /acct
Path: /payable
Options: recurse rename‐files
Status: Success
Report Name: sync.1._acct.rpt (bstnA)
Share: bills
Lost Items: 0
Found Items: 0
Synchronized Items: 0
Processed Items: 21
Namespace: medarcv
Volume: /rcrds
Path: /sprains
Options: recurse rename‐files
Status: Success
Report Name: sync.2._rcrds.rpt (bstnA)
Lost Items: 0
Found Items: 0
Synchronized Items: 0
Processed Items: 11
Path: /
Options: recurse rename‐files
Status: Success
Report Name: sync.3._rcrds.rpt (bstnA)
Lost Items: 1
Found Items: 0
Synchronized Items: 1
Processed Items: 245
bstnA(gbl)# ...
Focusing on a Single Namespace, Volume, or Path
You can add some options to show a smaller set of sync operations:
CLI Maintenance Guide
7 - 27
Chapter 7
Metadata Utilities: nsck and sync
show sync {files | directories} [namespace [volume vol‐path [path path]]]
where
files | directories chooses the type of sync operation,
namespace (1-30 characters) selects a namespace,
vol-path (1-1024 characters) narrows the scope to a specific
volume, and.
path (1-1024 characters) narrows the scope further, to a specific
virtual path in the volume (for example, ‘/home/jrandom’). This is
relative to the vol-path.
For example, this command shows all the sync-file operations performed on
the medarcv~/rcrds volume:
bstnA(gbl)# show sync files medarcv volume /rcrds
Namespace: medarcv
Volume: /rcrds
Path: /sprains
Options: recurse rename‐files
Status: Success
Report Name: sync.2._rcrds.rpt (bstnA)
Lost Items: 0
Found Items: 0
Synchronized Items: 0
Processed Items: 11
Path: /
Options: recurse rename‐files
Status: Success
Report Name: sync.3._rcrds.rpt (bstnA)
Lost Items: 1
Found Items: 0
Synchronized Items: 1
Processed Items: 245
bstnA(gbl)# ...
Clearing Sync Operations from the Output
The show sync command displays a running history of all sync operations.
The history goes back indefinitely, so the command can display a very large
number of records over time. You can clear all of these records at once, or
all records for a particular namespace, volume, or path. From priv-exec
mode, use the clear sync command:
clear sync {files | directories} [namespace [volume vol‐path [path path]]]
where
files | directories chooses the type of sync record to clear,
namespace (optional, 1-30 characters) identifies one namespace
from which to clear sync records. If this option is omitted, the
command clears all sync-files or sync-directories records from the
history.
7 - 28
Synchronizing Metadata with Actual Files
vol-path (optional, 1-1024 characters) narrows the scope to one
managed volume, and
path (optional, 1-1024 characters) narrows the scope further to a
specific virtual path. This is relative to the vol-path.
Before clearing the records, a prompt requests confirmation; enter yes to
confirm. After you clear the records, they no longer appear in the show sync
output.
For example, this command sequence shows all sync-file records, clears
them, then shows that there are none remaining:
bstnA(gbl)# show sync files
Namespace: wwmed
Volume: /acct
...
Found Items: 0
Synchronized Items: 1
Processed Items: 245
bstnA(gbl)# end
bstnA# clear sync files
Clear sync records? [yes/no] yes
bstnA# show sync files
bstnA# ...
Canceling a Sync Operation
To cancel an in-progress sync operation, go to priv-exec mode and use the
cancel sync command:
cancel sync {files | directories} namespace volume vol‐path path path
where
files | directories chooses the type of sync operation to cancel,
namespace (1-30 characters) identifies the namespace,
vol-path (1-1024 characters) is the volume, and
path (1-1024 characters) is the specific virtual path that is being
synchronized. This is relative to the vol-path.
A prompt requests confirmation before the CLI cancels the sync; enter yes
to confirm that you want to cancel the operation.
For example, this command cancels a sync-files operation in the “wwmed”
namespace:
bstnA(gbl)# end
bstnA# cancel sync files wwmed volume /acct path /
Cancel specified sync operations? [yes/no] yes
bstnA# ...
CLI Maintenance Guide
7 - 29
Chapter 7
Metadata Utilities: nsck and sync
Adding and Synchronizing Filer Subshares (CIFS)
This section only pertains to volumes that support CIFS. Skip to the next
section for NFS-only volumes.
A filer subshare is a shared directory that is under another shared directory.
A CIFS service and its managed volume can pass clients from a front-end
subshare through to the corresponding subshare on a back-end filer. When
clients access subshares this way, the filer can enforce the subshare’s
share-level ACL. For example, clients that connect to the “Y2005” share
(below) use ACL3; by default, when subshares are not supported, the
volume connects to the filer’s top-level share (through ACL1 in this
illustration) and descends to the directory from there.
Filer fs4
d:\exports
volume /rcrds
prescriptions
ACL1
Y2005
Y2005
ACL3
Two sections of the ARX® CLI Storage-Management Guide have
instructions for providing this CIFS-subshare support: Supporting Subshares
and their ACLs, on page 9-20 explains how to set up managed volumes, and
Exporting a Filer Subshare (and Using its ACL), on page 11-16 describes
the commands to set up a CIFS service. These instructions explain how to
work with subshares that exist on the filers before the managed volume
imports them.
The supported method for adding new subshares is to directly access a
back-end filer, add the subshare there, then synchronize the metadata with
the new subshare.
Note
This is contrary to the standard best practice. Share definitions and ACLs
are not managed by the volume, so this does not cause any metadata
inconsistencies. You can also create the underlying directory for the new
subshare.
7 - 30
Adding and Synchronizing Filer Subshares (CIFS)
Ensure the consistency of back-end subshares that correspond to front-end
CIFS service exports by using subshare synchronization. Refer to
Synchronizing Subshares, on page 9-25 of the ARX® CLI
Storage-Management Guide for complete details.
Important
If the volume is backed by any NetApp filers or EMC servers and you plan to
support free-space quotas on them (using freespace cifs-quota), prepare
the subshares directly on the filer before you synchronize subshares. The
subshare-replication process does not create NetApp qtrees or EMC
filesystems, and those special directories are required to support free-space
quotas. Before you run subshare replication, access the filers directly and
create one qtree or filesystem per subshare. Then, synchronize their
share-level ACLs and other attributes.
CLI Maintenance Guide
7 - 31
Chapter 7
Metadata Utilities: nsck and sync
Rebuilding a Namespace
The nsck rebuild utility completely rebuilds all managed volumes in a
namespace: it re-imports the back-end shares and rebuilds its metadata
databases. This command causes a brief interruption in service, and it forces
all NFS clients to unmount and then re-mount their managed volumes; use
this only in situations where sync files fails. This has no effect on direct
volumes.
Note
By default, this stops all modifications (client writes and file renames on
import) in all managed volumes after the rebuild. Essentially, the nsck utility
issues a no modify for every managed volume in the namespace.
To guarantee that managed-volume modifications are enabled after the
rebuild, run the modify command in each volume and raise the
reimport-modify flag before you rebuild the namespace. The reimport-modify
flag stops the nsck utility from running no modify.
If you do not do this but the rebuild/import succeeds without any collisions,
you can use the modify command on each volume after the rebuild.
For details on the reimport-modify command, see Allowing the Volume to
Modify on Re-Import, on page 9-8 of the ARX® CLI Storage-Management
Guide.
From priv-exec mode, use the nsck rebuild command to rebuild all managed
volumes in a namespace:
nsck namespace rebuild
where namespace (1-30 characters) is the name of the namespace to
rebuild. Use the show namespace command to see a list of configured
namespaces.
The CLI prompts for confirmation before re-importing all managed volumes
in the namespace: enter yes to continue. Enter no to cancel the rebuild.
You can run one nsck job at a time on a given volume. Use show nsck to
monitor the progress of nsck jobs; see Showing the Progress of nsck and
sync Jobs, on page 7-4.
For example, the following command sequence exits to priv-exec mode and
rebuilds the ‘wwmed’ namespace.
bstnA(gbl)# end
bstnA# nsck wwmed rebuild
Reimport all shares in the namespace wwmed? [yes/no] yes
bstnA# ...
7 - 32
Rebuilding a Namespace
Directory Mastership After a Rebuild
A managed volume sometimes duplicates (or stripes) its directories on
multiple shares. Each directory has a single master, and may have one or
more stripes. The master directory is on the share where it was first found,
and each stripe is a copy on another share. If a filer share has the master
instance of a directory, the directory tends to grow on that share; by default,
a new file goes to the same share as its parent’s master directory. For
example, if a client creates a “newfile.doc” file in “\mydir,” and “\mydir”
has its master on the nas20 filer, the volume sends “newfile.doc” to nas20
by default.
A file-placement rule can change the placement of master directories during
import, normal operation, and re-import. The ARX® CLI
Storage-Management Guide describes how to use these rules to set
master-directory placement: refer to Matching Directories Only, on page
14-7 and Matching and Promoting Directories, on page 14-9. Additionally,
you can set the priority of the volume’s shares so that the highest-priority
shares have mastership from the beginning of the import; see Setting the
Share’s Priority (for Tiering), on page 9-36 of the same storage manual. If
no such rules or priorities are configured for master-directory placement,
mastership of directories is not deterministic after the rebuild. After the
rebuild is finished, you can correct this by adding a new file-placement rule.
Rebuilding a Volume
You can narrow the focus of an nsck rebuild to a single volume. To rebuild
one volume, add the optional volume clause to the end of the nsck rebuild
command:
nsck namespace rebuild volume volname
where:
name (1-30 characters) is the name of the namespace to rebuild.
Use the show namespace command to see a list of configured
namespaces.
volume volname (optional, 1-256 characters) limits the rebuild to
the chosen volume (for example, ‘/home’).
The CLI prompts for confirmation before re-importing the volume’s shares:
enter yes to continue. Enter no to cancel the rebuild.
Note
As mentioned above, this stops all managed-volume modifications (client
writes and file renames on import) after the rebuild. Essentially, the nsck
utility issues a no modify for the volume.
To guarantee that modifications are enabled after the rebuild, run the
modify command and raise the reimport-modify flag before you rebuild the
volume. The reimport-modify flag stops the nsck utility from running no
modify on the volume.
CLI Maintenance Guide
7 - 33
Chapter 7
Metadata Utilities: nsck and sync
If you do not do this but the rebuild/import succeeds without any collisions,
you can use the modify command after the rebuild.
For example, the following command sequence exits to priv-exec mode and
rebuilds the ‘/etc’ volume in the ‘archives’ namespace:
bstnA(gbl)# end
bstnA# nsck archives rebuild volume /etc
Reimport all shares from volume /etc in namespace archives? [yes/no] yes
bstnA# show nsck
Op Id Op Type Namespace:Path Status
‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
...
47 report archives:/etc Rebuild in progress
bstnA# ...
Forcing the Rebuild
It is possible for an nsck-rebuild job to freeze in an unfinished state: for
example, the job freezes if one of the back-end filers goes down during the
re-import. In this situation, you should resolve the problem and then restart
the rebuild. To override the unfinished rebuild job and start a new one, add
the optional force flag to the nsck rebuild command.
nsck namespace rebuild [volume volname] force
For example, the following command sequence exits to priv-exec mode and
forces a rebuild for the ‘archives’ namespace:
bstnA(gbl)# end
bstnA# nsck archives rebuild force
Reimport all shares in the namespace archives? [yes/no] yes
bstnA# ...
7 - 34
De-Staging a Namespace’s Managed Volumes
De-Staging a Namespace’s Managed Volumes
You may want to perform filer recoveries directly on the filer. To directly
access the shares behind a namespace’s managed volumes, you first release
(or de-stage) the shares from the volumes. This removes all metadata from
all managed volumes and then disables all of the volumes’ shares. Once the
volumes are de-staged, you can access all of their shares directly (that is, not
through a VIP) without any risk of metadata inconsistencies. After you
restore all files to the shares, you can re-enable all of the namespace’s
managed volumes.
As with a rebuild, NFS clients must unmount and remount the volumes after
the shares are re-enabled.
From priv-exec mode, use the nsck destage command to release all shares
from a namespace’s managed volumes.
nsck namespace destage
where:
namespace (1-30 characters) is the name of the namespace to be
destaged. Use the show namespace command to see a list of
configured namespaces.
destage specifies to destage the namespace metadata and prepare it
for reimport.
The CLI prompts for confirmation before releasing the shares: enter yes to
continue. Enter no to cancel the destage operation.
Important
While the namespace is de-staged, its managed volumes are inaccessible to
clients.
Note
As with nsck ... rebuild, this disables all modifications (client writes and file
renames on import) in the namespace’s managed volumes. That is, no
modifications are possible after the managed volumes are later re-enabled.
To prevent this, someone must first run the modify command and raise the
reimport-modify flag.
You can run one nsck job at a time on a given volume. Use show nsck to
monitor the progress of nsck jobs; see Showing the Progress of nsck and
sync Jobs, on page 7-4.
For example, the following command sequence exits to priv-exec mode and
destages the “wwmed” namespace:
bstnA(gbl)# end
bstnA# nsck wwmed destage
The namespace is in use by NFS global service 'ac1.medarch.org'.
This operation will remove entries for all shares
from the namespace metadata. To reimport a destaged share,
CLI Maintenance Guide
7 - 35
Chapter 7
Metadata Utilities: nsck and sync
enable the share.
% WARNING: Namespace wwmed is in use by global services.
Destaging the namespace will disrupt all clients using these services.
Destage the namespace anyway? [yes/no] yes
bstnA# ... De-Staging the Volumes in a Volume Group
Some metadata failures require a destage of all volumes in the same volume
group. Volume groups are a means of isolating namespaces in the ARX’s
memory so that the failure of one or more namespaces in one volume group
does not affect the performance of namespaces in other volume groups. The
ARX® CLI Storage-Management Guide describes volume groups in detail:
refer to Assigning The Volume To A Volume Group (optional), on page 9-48.
For example, suppose a volume uses an NFS metadata share, and the mount
to that metadata share hangs. The volume (which could support NFS, CIFS,
or both for its clients) gradually goes offline. Other volumes in the same
volume group will fail eventually, also. The solution for this problem is to
restart all of the volumes in the volume group, which results in a re-import
of the volumes. You can destage all of them without affecting any volumes
in other volume groups. Then, you can use the priv-exec reload command
to fail over to the peer ARX and restart all the volumes. Only the volumes in
the affected volume group must re-import.
To destage the volumes in one volume group, add the optional volume-group
argument to the end of the nsck destage command:
nsck namespace destage volume‐group volumegroupid
where:
namespace (1-30 characters) is the name of the namespace where
the destage occurs. Use the show namespace command to see a
list of configured namespaces.
destage specifies to destage the namespace metadata and prepare it
for reimport.
volume-group volumegroupid (optional, 1-8) identifies a volume
group used by this namespace. You can use the show
volume-group command for a full list of the volume groups on
this ARX, and to find which volume groups are assigned to this
namespace.
The CLI prompts for confirmation before releasing the volumes: enter yes to
continue. Enter no to cancel the destage operation. If any of the volumes’
metadata shares support NFS and are unavailable, the prompt recommends a
reload to initiate a failover; this is required to correct a hung NFS mount at
a metadata share, as described above.
7 - 36
De-Staging a Namespace’s Managed Volumes
You can run one nsck job at a time on a given volume. Use show nsck to
monitor the progress of nsck jobs; see Showing the Progress of nsck and
sync Jobs, on page 7-4.
For example, the following command sequence exits to priv-exec mode,
shows all volume groups, and releases all volumes running on volume group
2:
bstnA(gbl)# end
bstnA# nsck wwmed destage volume /it
bstnA# show volume‐group
Switch: bstnA
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Volume Group 1
‐‐‐‐‐
Physical Processor: 1.1
State: Normal; maximum instances
Share credits: 4 shares used (124 credits remain of total 128)
Direct share credits: 3 direct shares used (2045 credits remain of total 2048)
Volume credits: 2 volumes used (30 credits remain of total 32)
File credits: 4.0 M files reserved (252 M credits remain of total 256 M)
Namespace Domain Volume State
‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐
medco 2 /vol Enabled
wwmed 1 /acct Enabled
2 Namespaces 2 Volumes
Volume Group 2
‐‐‐‐‐
Physical Processor: 1.1
State: Normal; maximum instances
Share credits: 9 shares used (119 credits remain of total 128)
Direct share credits: 6 direct shares used (2042 credits remain of total 2048)
Volume credits: 6 volumes used (26 credits remain of total 32)
File credits: 72 M files reserved (184 M credits remain of total 256 M)
Namespace Domain Volume State
‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐
medarcv 1 /rcrds Enabled
medarcv 1 /lab_equipment Enabled
medarcv 1 /test_results Enabled
insur 2 /claims Enabled
2 Namespaces 4 Volumes
...
bstnA# nsck medarcv destage volume‐group 2
This operation will remove entries for all shares in the volume group
from the namespace metadata. To reimport a destaged share,
enable the share. The following volumes will be affected:
/rcrds
/lab_equipment
/test_results
Destage volumes hosted by volume group 2 in the namespace "medarcv"? [yes/no] yes
CLI Maintenance Guide
7 - 37
Chapter 7
Metadata Utilities: nsck and sync
bstnA# ... De-Staging a Single Volume
You can narrow the focus of an nsck destage even further, to a single
volume. To destage one volume, add the optional volume clause to the end
of the nsck destage command:
nsck namespace destage volume volname
where:
namespace (1-30 characters) is the name of the namespace where
the destage occurs. Use the show namespace command to see a
list of configured namespaces.
destage specifies to destage the namespace metadata and prepare it
for reimport.
volume volname (optional, 1-256 characters) is the volume to
destage (for example, ‘/var’).
The CLI prompts for confirmation before releasing the volume: enter yes to
continue. Enter no to cancel the destage operation.
You can run one nsck job at a time on a given volume. Use show nsck to
monitor the progress of nsck jobs; see Showing the Progress of nsck and
sync Jobs, on page 7-4.
For example, the following command sequence exits to priv-exec mode and
releases a volume from the “wwmed” namespace:
bstnA(gbl)# end
bstnA# nsck wwmed destage volume /it
Volume /it is in use by NFS global service 'ac1.medarch.org'.
This operation will remove entries for all shares in the volume
from the namespace metadata. To reimport a destaged share,
enable the share.
% WARNING: Volume /it in namespace wwmed is in use by global services.
Destaging the volume will disrupt all clients using this volume.
Destage the volume anyway? [yes/no] yes
bstnA# ... Forcing the De-Stage
As mentioned in the section about rebuilding a namespace, it is possible for
filer error or network glitch to freeze an nsck job in an unfinished state.
Once the error is resolved, you may want to de-stage the volume or
namespace; however, nsck only allows a single job to run on a given
volume. To override the unfinished nsck job and start a new one, add the
optional force flag to the nsck destage command.
7 - 38
De-Staging a Namespace’s Managed Volumes
nsck name destage [volume‐group volumegroupid| volume volname] force
For example, the following command sequence exits to priv-exec mode and
forces a de-stage for the ‘wwmed~/it’ volume:
bstnA(gbl)# end
bstnA# nsck wwmed destage volume /it force
Volume /it is in use by NFS global service 'ac1.medarch.org'.
This operation will remove entries for all shares in the volume
from the namespace metadata. To reimport a destaged share,
enable the share.
% WARNING: Volume /it in namespace wwmed is in use by global services.
Destaging the volume will disrupt all clients using this volume.
Destage the volume anyway? [yes/no] yes
bstnA# ...
Re-Enabling the Shares
With the share released from its namespace, you can access the share
directly at its filer. Once you are finished, you must re-enable all shares in
the volume(s) to restart the import process.
When the shares are ready, re-enable each of them to import them back into
the namespace. From gbl-ns-vol mode, you can use enable shares to
enable all of the volume’s shares at once; see Enabling All Shares in the
Volume, on page 9-54 of the ARX® CLI Storage-Management Guide.
Recall that the modify command is disabled by nsck ... destage unless the
reimport-modify flag was also raised. If the reimport-modify flag was down
during the destage, you have the opportunity to enable modify before
enabling shares (see Allowing the Volume to Modify on Import, on page 9-6
of the ARX® CLI Storage-Management Guide).
To continue the example:
bstnA# global
bstnA(gbl)# namespace wwmed
bstnA(gbl‐ns[wwmed])# volume /it
bstnA(gbl‐ns‐vol[wwmed~/it])# modify
Automatically re‐enable volume modify mode during nsck rebuild? [yes/no] yes
bstnA(gbl‐ns‐vol[wwmed~/it])# enable shares
bstnA(gbl‐ns‐vol[wwmed~/it])# ...
CLI Maintenance Guide
7 - 39
Chapter 7
Metadata Utilities: nsck and sync
Migrating Metadata to a New Back-End Share
Managed volumes require fast and extremely-reliable back-end shares to
store their metadata. A slow metadata share can affect client service as well
as import speed. To migrate a volume’s metadata from a slow back-end
share to one on a faster filer, use the nsck migrate-metadata command:
nsck namespace migrate‐metadata volume vol‐path target ext‐filer {nfs3 | nfs3tcp | cifs} path
where:
namespace (1-30 characters) identifies the namespace.
vol-path (1-1024 characters) is the managed volume that requires
new metadata storage. Use forward slashes (/) in the path, even for
CIFS volumes.
ext-filer (1-64 characters) identifies the target share for the
volume’s metadata. This is the external-filer name for the filer; use
show external-filer for a complete list of configured filers.
nfs3 | nfs3tcp | cifs is a required choice. This is the protocol used to
access the metadata share; it can be different from any of the
protocols used for the managed volume. The choices are NFSv3
over UDP (nfs3), NFSv3 over TCP (nfs3tcp), or CIFS.
path (1-1024 characters) selects the metadata share and path (for
example, ‘/’ or ‘/usr/acoMD’). For a CIFS share, this is the share
name (and possibly a path to a subshare); use forward slashes (/),
even for CIFS shares.
Important
This stops all client access to the volume during the metadata migration.
Whether or not the migration succeeds, client access resumes as soon as the
operation ends.
The CLI prompts for confirmation before it starts the migration; enter yes to
proceed. The nsck utility copies all of the metadata to the target share,
verifies its integrity at the target share, then switches the managed volume
over to the new metadata share. If the migration fails in any way before the
last step, the volume comes back online with its metadata still on the
original share. You must manually restart the migration after a cancellation
or unexpected failure.
As with all nsck jobs, this operation produces a report to show its progress.
The CLI shows the report name after you invoke the command. Use show
reports for a full list of nsck reports, and use show, tail, or grep to view one
report. The report shows the source and target shares, the size of the
metadata, and the time required to migrate it.
For example, this command sequence migrates metadata for the
wwmed~/acct volume and then shows the report:
bstnA(gbl)# end
bstnA# nsck wwmed migrate‐metadata volume /acct target nas3 nfs3 /vol/vol2/meta7
7 - 40
Migrating Metadata to a New Back-End Share
Volume /acct is in use by NFS global service 'ac1.medarch.org'.
Volume /acct in namespace wwmed is in use or being browsed by global services.
Migrating metadata for this volume will disrupt clients using these services.
No other volume will be affected by this procedure.
Proceed with metadata migration? [yes/no] yes
Starting metadata migration for wwmed:/acct. 1835008 bytes to be transferred.
Detailed status contained in report: migrate_metadata.34.rpt on switch bstnA
bstnA# show reports migrate_metadata.34.rpt
**** Metadata Migration Report: Started at Wed Feb 24 02:15:36 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
Namespace: wwmed
Volume: /acct
Original Location: nas1(192.168.25.21): /vol/vol1/meta1 (nfs3)
Target Location: nas3(192.168.25.47): /vol/vol2/meta7 (nfs3)
Metadata Size: 2,232,320 (2.1 MB)
**** Total processed: 0
**** Elapsed time: 00:00:04
**** Metadata Migration Report: DONE at Wed Feb 24 02:15:40 2010 ****
Canceling a Metadata Migration
You can cancel a migration any time before it has restarted the volume. The
restart occurs after the metadata is successfully copied to the new share. To
cancel a metadata migration in an earlier phase, go to priv-exec mode and
use the cancel migrate-metadata command:
cancel migrate‐metadata namespace volume vol‐path
where
namespace (1-30 characters) identifies the namespace,
vol-path (1-1024 characters) is the volume, and
A prompt requests confirmation before the CLI cancels the migration; enter
yes to confirm.
For example, this command cancels a metadata migration for the
“medarcv~/rcrds” volume:
bstnA(gbl)# end
bstnA# cancel migrate‐metadata medarcv volume /rcrds
Are you sure you want to cancel this migration? [yes/no] yes
Metadata migration cancelled successfully.
bstnA# ...
CLI Maintenance Guide
7 - 41
Chapter 7
Metadata Utilities: nsck and sync
Clearing All nsck Jobs
From priv-exec mode, use the clear nsck command to clear all the nsck jobs
that are currently pending, and to clear all finished jobs from the job history
in show nsck:
clear nsck
The CLI prompts for confirmation before clearing all jobs; enter yes to clear
all nsck jobs. This does not delete the nsck reports; use delete reports
nsck-report-name to remove an nsck report, or show reports to see all
reports.
For example:
bstnA(gbl)# end
bstnA# clear nsck
Clear all nsck records? [yes/no] yes
bstnA# show nsck
Op Id Op Type Namespace:Path Status
‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
bstnA# ...
Clearing One nsck Job
Use the nsck-job ID with the clear nsck command to clear one pending (or
finished) nsck job:
clear nsck job‐id
where job-id (1-2,147,483,647) identifies the nsck job to clear. This ID
appears in the name of the nsck report.
As above, the CLI prompts for confirmation before clearing the job. Enter
yes to proceed.
For example, the following command sequence stops nsck-job 1, which was
still pending:
bstnA(gbl)# show nsck
Op Id Op Type Namespace:Path Status
‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 report wwmed:/acct Pending
bstnA(gbl)# end
bstnA# clear nsck 1
Clear NSCK ID 1? [yes/no] yes
bstnA# ...
Truncating a Report
To conserve CPU cycles and/or internal-disk space, you may want to stop a
report before it is finished. A oversized, CPU-intensive report could
possibly have an effect on namespace performance. You can stop the report
without stopping the nsck job. From priv-exec mode, use the truncate-report
command to stop all report processing and truncate the report file:
7 - 42
Clearing All nsck Jobs
truncate‐report report‐name
where report-name (1-255 characters) specifies report to truncate.
The CLI prompts for confirmation before truncating the report. Enter yes to
continue.
For example, the following command sequence truncates an inconsistencies
report:
bstnA(gbl)# end
bstnA# truncate report inconsistencies.29.rpt
Truncate report ''inconsistencies.29.rpt''? [yes/no] yes
bstnA# ...
CLI Maintenance Guide
7 - 43
Chapter 7
Metadata Utilities: nsck and sync
7 - 44
8
Troubleshooting Tools
• Overview
• Showing All Active Alarms
• Showing Time Skews Between the ARX and Other
Servers
• Accessing the Syslog
• Sending Logs to an External Server
• Listing Current System Tasks
• Collecting Diagnostic Information
• Setting Up Remote Monitoring By F5 Support
• Running Show Commands from a Remote Host
• Notification Rules
• Statistics Monitoring
Overview
Overview
This chapter describes the basic tools and procedures for troubleshooting the
ARX.
• You can get a list of all alarm conditions with the show health command.
• The show health time-skew command shows the clocking skew between
the ARX and its network peers.
• The ARX keeps its logs in a syslog file. You can access the syslog file by
using show, grep, and tail.
• You can forward all syslog messages (as they are logged) to one or more
external hosts.
• You can show the current tasks running on the system.
• You can collect all diagnostic information from a troubled switch and
send it to a remote site. This is for sending information to F5 for
thorough diagnosis.
• Using SSH, you can run show commands from a remote host.
These are basic tools for troubleshooting the ARX. Later chapters describe
procedures for troubleshooting network connections and managed volumes.
CLI Maintenance Guide
8-3
Chapter 8
Troubleshooting Tools
Showing All Active Alarms
Several of the ARX’s Enterprise SNMP traps signal that an alarm condition
is now active. This indicates a system failure, or that the system has crossed
a resource threshold of some kind. If the condition clears or the system
drops back below the threshold, another trap clears the alarm condition.
From any mode, you can use the show health command to show all
currently-active alarms on the system:
show health
Refer to the ARX SNMP Reference for detailed information about any trap,
including correction procedures.
For example, this shows current alarm conditions on the ARX named
“bstnA:”
bstnA(cfg)# show health
System Health Information
Date ID Event Description
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Mon Jan 24 00:50:27 2011 (540) ‐ powerFail Slot power 1/2 absent
Mon Jan 24 00:50:27 2011 (540) ‐ powerFail Slot power 1/1 absent
Mon Jan 24 00:52:40 2011 (185) ‐ gatewayOffline Client gateway 10.1.11.218 is offline.
Mon Jan 24 00:54:52 2011 (411) ‐ nsmStandby Processor 2.2 is in standby.
Mon Jan 24 00:55:04 2011 (411) ‐ nsmStandby Processor 2.4 is in standby.
Mon Jan 24 00:55:04 2011 (411) ‐ nsmStandby Processor 2.3 is in standby.
Mon Jan 24 00:55:04 2011 (411) ‐ nsmStandby Processor 2.1 is in standby.
Mon Jan 24 01:00:51 2011 (826) ‐ virtualServiceAclUpdateFail 192.168.25.15:/acct:NIS information has not been fully resolved by the NIS daemon.
Mon Jan 24 01:02:17 2011 (148) ‐ downRevAdForestLevelRaise The forest functional level of domain MEDARCH.ORG is not capable of supporting constrained delegation
Mon Jan 24 01:09:43 2011 (19) ‐ archiveFreeSpaceThresholdRaise fileRecordsMed, fs4:arx_file_archv:is running low on freespace (<10 GB Free).
Mon Jan 24 01:20:05 2011 (826) ‐ virtualServiceAclUpdateFail 192.168.25.15:/claims:NIS information has not been fully resolved by the NIS daemon.
bstnA(cfg)# ...
Clearing SNMP Traps
After you have investigated an SNMP trap and resolved the underlying
issue, you can dismiss the trap using the privileged-exec mode CLI
command clear health. The command syntax is:
clear health trap
where trap is the trap or event name.
For example, the following command dismisses the filerAccessDenied trap:
bstnA# clear health filerAccessDenied
8-4
Showing Time Skews Between the ARX and Other Servers
Showing Time Skews Between the ARX and Other
Servers
Several ARX processes depend on time synchronization with other servers
in the network. For example, some migration policies are based on
last-modified or last-accessed times, and Kerberos authentication uses
tickets with expiration times. If the ARX time is drastically different from
DC time or filer time, these features behave unpredictably.
We recommend using NTP to synchronize time between the ARX and other
network devices. For information on connecting the ARX to your NTP
server(s), refer to Configuring NTP, on page 4-15 of the ARX® CLI
Network-Management Guide.
From any mode, you can use the show health time-skew command to see
the time skew between the ARX, its DCs, and its back-end filers:
show health time‐skew [timeout seconds]
where timeout seconds (optional, 1-3600) specifies the maximum
time to wait for responses from each server. The default is 3 seconds.
The ARX often makes two or more connection attempts to each server,
and this timeout applies to each attempt. Therefore, the command could
take twice as long (or longer, in some cases) than the timeout you set
here. Also, this timeout applies to each individual server, so the overall
time for multiple servers may be longer. You can always use <Ctrl-C>
to return to the CLI prompt before the command finishes.
The output is a table with one row per external device, showing the device’s
IP address, its role for the ARX (“External Filer” or “Domain Controller”),
and its time skew with respect to ARX time.
For example, this command shows the time skews between the “bstnA”
switch and the network devices that it uses:
bstnA(cfg)# show health time‐skew
IP Address Role Observed Time Skew vs. ARX
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
192.168.25.22 External Filer 00:18:41 ahead
192.168.25.24 External Filer 00:00:00
192.168.25.25 External Filer 04:16:19 behind
192.168.25.48 External Filer 3 d 03:59:15 ahead
192.168.25.22 External Filer 00:00:00
192.168.25.44 External Filer 00:00:00
192.168.25.19 External Filer 00:00:00 ahead
192.168.25.71 External Filer 00:00:00
192.168.25.27 External Filer 00:01:29 behind
192.168.25.20 External Filer 00:01:29 behind
192.168.25.28 External Filer 00:01:29 behind
192.168.25.29 External Filer 00:01:29 behind
192.168.25.21 External Filer 00:00:00
192.168.25.47 External Filer 00:00:00
192.168.25.51 External Filer 00:00:00
192.168.25.102 Domain Controller 00:01:29 behind
192.168.25.104 Domain Controller 00:01:29 behind
192.168.202.9 Domain Controller 00:01:30 behind
192.168.202.10 Domain Controller 00:01:30 behind
192.168.202.11 Domain Controller 00:01:29 behind
CLI Maintenance Guide
8-5
Chapter 8
Troubleshooting Tools
172.16.124.73 Domain Controller 00:01:29 behind
192.168.25.103 Domain Controller 00:01:29 behind
172.16.168.21 Domain Controller 00:01:29 behind
10.19.230.94 Domain Controller 00:01:30 behind
192.168.25.109 Domain Controller 00:01:30 behind
192.168.25.110 Domain Controller 00:01:30 behind
172.16.108.139 Domain Controller 00:00:41 behind
172.16.110.5 Domain Controller 00:00:41 behind
172.16.120.5 Domain Controller 00:00:41 behind
172.16.213.9 Domain Controller 00:01:06 behind
172.16.240.88 Domain Controller 00:01:07 behind
172.16.210.7 Domain Controller 00:01:06 behind
172.16.74.88 Domain Controller 00:01:30 behind
bstnA(cfg)# ...
8-6
Accessing the Syslog
Accessing the Syslog
The syslog (short for System Log) contains all log messages from the
system’s internal software. Processes add informational messages to this log
as they run, as well as error messages of varying severities. For an
alphabetical list of syslog messages, see the ARX Log Catalog.
The syslog is rotated by the system whenever it exceeds 75 Megabytes. The
rotation process renames the current syslog file “syslog.1.log,” the current
syslog.1.log becomes syslog.2.log, and so on. The oldest log kept is
syslog.100.log; older logs are deleted. To see a list of all syslogs on the
current system, use the show logs command:
show logs
For example, this command is run on a system with an active syslog and no
backups:
bstnA(cfg)# show logs
logs
catalina.out Nov 21 03:27 0
dfpd.dump.0 Nov 20 14:31 419
dmesg Nov 21 03:23 24k
error.log Nov 21 03:59 897k
fastpath Nov 21 03:51 363
firebird.log Nov 21 03:23 26k
gziplog Nov 20 14:32 96
kernel.log Nov 21 03:51 583k
megaserv.log Nov 21 03:54 9.5k
nisd_dump.0 Nov 21 03:28 283
nlmd.dump.0 Nov 20 14:31 2.7k
nlmd.dump.1 Nov 20 14:31 2.7k
om.install.log Nov 21 02:39 53
om.upgrade.log Nov 21 02:40 176k
originalOidList.txt Nov 21 03:24 23k
pxlog.log Nov 21 03:27 109k
ramecc.log Nov 21 03:24 10k
rtmd.dump.0 Nov 20 14:31 698
scm‐top.dump Nov 21 03:43 5.7M
scm‐vmstat.dump Nov 21 03:59 18k
statsd.dump.0 Nov 20 14:31 20k
syslog Nov 21 03:59 13M
traplog Nov 21 03:56 7.8k
traplog.1 Nov 21 03:38 26k
traplog.10 Nov 20 13:52 25k
traplog.2 Nov 20 17:05 25k
traplog.3 Nov 20 16:28 25k
traplog.4 Nov 20 15:59 25k
traplog.5 Nov 20 15:30 25k
traplog.6 Nov 20 15:01 25k
traplog.7 Nov 20 14:32 25k
traplog.8 Nov 20 14:12 25k
traplog.9 Nov 20 13:57 28k
txnmond.dump.0 Nov 20 14:28 0
CLI Maintenance Guide
8-7
Chapter 8
Troubleshooting Tools
Tailing the Syslog
You can use the tail command from any mode to view syslog messages as
they are added to the log:
tail logs file‐name follow
where
logs is required to specify the “logs” directory,
file-name (1-255 characters) identifies the file to tail, and
follow is required to follow the syslog as it grows.
Use tail logs syslog follow to view the syslog file. Use <Ctrl-C> to stop the
tail output and return to the CLI prompt.
For example:
prtlndA> tail logs syslog follow
2004‐06‐18T18:26:33.038‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[5691]: Accepted keyboard‐interactive for admin from 172.16.22.183 port 58849 ssh2
2004‐06‐18T18:26:33.040‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[5691]: lastlog_get_entry: Error reading from /var/log/lastlog: Bad file descriptor
2004‐06‐18T18:26:48.294‐0400:bstnA:1‐1‐SCM‐960:L2SW_DRV‐0‐5‐MSG5:: Disable Mirror Port:
2004‐06‐18T18:28:39.195‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐4‐FILTER:: sntpc: resetting on error 0.117 > 0.102
2004‐06‐18T18:28:39.222‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐4‐FILTER:: sntpc: resetting on error 0.117 > 0.102
2004‐06‐18T18:31:22.008‐0400:bstnA:5‐2‐ASM_FC‐602:LIBCIFS‐0‐7‐MSG7:: connection to \\10.51.1.23\histories deleted
2004‐06‐18T18:37:13.257‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[9204]: WARNING: /usr/local/etc/moduli does not exist, using old modulus
2004‐06‐18T18:37:13.371‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[9204]: Could not reverse map address 172.16.22.183.
2004‐06‐18T18:37:14.028‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[9204]: Accepted keyboard‐interactive for admin from 172.16.22.183 port 60054 ssh2
2004‐06‐18T18:37:14.032‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[9204]: lastlog_get_entry: Error reading from /var/log/lastlog: Bad file descriptor
...
Showing the End of the Syslog
You can show the last few lines in the syslog file, without following any
new syslog entries, by omitting the follow keyword:
tail logs file‐name [number‐lines]
where
file-name (1-255 characters) identifies the syslog file to tail, and
number-lines (optional, 1-4096) is the number of lines to show. By
default, the command shows the last 24 lines in the file.
For example, the following command shows the last five lines in the current
syslog file:
bstnA> tail logs syslog 5
2004‐06‐18T18:31:22.008‐0400:bstnA:5‐2‐ASM_FC‐602:LIBCIFS‐0‐7‐MSG7:: connection to \\10.51.1.23\histories deleted
2004‐06‐18T18:37:13.257‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[9204]: WARNING: /usr/local/etc/moduli does not exist, using old modulus
8-8
Accessing the Syslog
2004‐06‐18T18:37:13.371‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[9204]: Could not reverse map address 172.16.22.183.
2004‐06‐18T18:37:14.028‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[9204]: Accepted keyboard‐interactive for admin from 172.16.22.183 port 60054 ssh2
2004‐06‐18T18:37:14.032‐0400:bstnA:1‐1‐SCM‐0:LOG‐0‐6‐FILTER:: sshd[9204]: lastlog_get_entry: Error reading from /var/log/lastlog: Bad file descriptor
bstnA>
Log Components
Every log message originates from a log component (such as SCM_CLI in
the sample above). A log component is a source of syslog messages,
typically an internal process or group of processes. The table below is an
alphabetical list of all log components, with a brief description and an
indication of the board(s) where the software runs.
Log Component
AFFINITY
AFN_NET
Description
Affimgrd and libaffin, which manage the assignment of internal
processes to CPU cores.
IPC Abstraction Layer, for communication between internal ARX
processes.
API
API Services.
APP_RON_RTMD
RON Route Table Maintenance Daemon.
AT
AUTH_CONSOLE
AUTH_HTTP
AUTH_HTTPS
AUTH_SSH
AUTH_TELNET
AUTO_DIAG_CLI
BESPD
BOOTPD
CATALOG_INTERNAL
CHASS
CLI Maintenance Guide
AT Library. This is deprecated, so it is unlikely to yield any log
messages.
Console Authentication. This component performs authentication for
administrators who log into the Console (serial) port.
HTTP Authentication. This component performs authentication for
administrators who access the GUI through HTTP.
HTTPS Authentication. This component performs authentication for
administrators who access the GUI through HTTP over SSL, or HTTPS.
SSH Authentication. This component performs authentication for
administrators who access the CLI through Secure SHell (SSH).
Telnet Authentication. This component performs authentication for
administrators who access the CLI through Telnet.
Auto Diagnostics, which gathers input/output statistics and monitors for
service degradation.
Back-end Share Probing daemon, which periodically probes the shares
behind ARX volumes and checks their health.
BOOTP Daemon, or the boot-protocol server, which manages ARX
boots and reboots.
Message Catalog Internal Errors.
Chassis Manager, which implements chassis operations such as 'reload,'
'firmware upgrade,' and hardware monitoring.
8-9
Chapter 8
Troubleshooting Tools
Log Component
CHASS_LIB
CIFS_CLI
CIFS_SHIM_LIB
CIFSCONFD
Description
Chassis Manager Library. The chassis manager implements chassis
operations such as 'reload,' 'firmware upgrade,' and hardware
monitoring.
CIFS CLI.
Interface to metadata storage on CIFS filers. Metadata is data about
managed-volume files, such as their locations on back-end filers.
CIFS Configuration Daemon, which manages one front-end CIFS
service.
CLI
Command Line Interface.
CLI_NFS_COPY
Copy to/from NFS namespace.
CLI_RUN_EXIM
Run exim4 from the CLI..
CLI_WIZARD
Initial Interview, which prompts with questions and performs initial
configuration the first time the ARX boots.
CLUSTER
Not supported.
COMMON_DNAS
Common DNAS Messages.
COMMON_NIS
Common Network Information System (NIS) messages. NIS servers
provide a lookup service for NFS servers, to manage large NFS access
lists.
COMMONLIB
Not supported.
CORE
Core collector.
CRMD
DDBD
DEBUG
DFPD
DME
Critical Resource Monitor Daemon, which makes HA failover decisions
based on external filers, routers, etc.
Distributed Database Library. This is for the internal database, which
stores the ARX configuration. You can see the full configuration with
'show running-config' and 'show global-config'.
Internal debugging - used for development only.
DNAS Fast Path Manager Daemon, which configures managed volumes
in the NSM data plane.
Policy Data Mover Engine (DME). This implements file migrations from
one back-end filer to another.
DMOUNTD
Distributed Mount Daemon for NFS mounts.
DMSG_LIB
DNAS Message Library.
DNAS_IMPORT
DNAS_MD_MIGRATE
DNAS_PGRP
DNAS_POLICY
8 - 10
DNAS Import Messages. An import occurs when a filer share is enabled
in an enabled managed volume. This is the process of walking the
directory tree of the share and recording all of its files and directories in
managed-volume metadata.
DNAS Metadata Migration, which moves managed-volume metadata
from one external filer to another.
DNAS Process Group and NFS. DNAS, or Distributed NAS, is the
internal name for namespace software.
Inline policy events that occur during normal volume processing, such as
file creates, directory renames, and other client actions. This is off by
default because it generates a great deal of log messages, enough to
potentially affect client traffic.
Accessing the Syslog
Log Component
Description
DNAS_SINIT
DNAS Storage Initialization.
DNAS_SREMOVE
DNAS Storage Removal.
DNC_LIB
DOMAIN_JOIN
DR
DT
EMAILHOME
ENVLIB
EVAL_NET_RESULT
EXIMD
FCN
FCND
DNAS Configuration Library for NFS. DNAS is the internal name for
namespace software.
Active Directory domain joining components, which join an ARX-CIFS
service to a Windows domain.
Disaster Recovery, which involves loading a configuration on a
backup-ARX site and activating the configuration on command.
Direct Transport processes. This is a high-speed inter-process
communication (IPC) library.
Email home daemon and CLI commands.
Environmental Library, for monitoring the hardware platform. This only
applies to the ARX-500.
The results of joining an Active Directory (AD) domain.
Exim Daemon, which sends RPC requests to the exim message-transfer
agent. That agent sends SMTP (email) messages from the ARX to
external devices.
File Change Notification, for API access to snapshotted configuration
and metadata.
File Change Notification daemon which provides API access to
snapshotted configuration and metadata.
FFP
Fast Filter Processor.
FFP_UTIL
Fast Filter Processor Library.
FFPD
Fast Filter Processor Daemon.
FILER_MGMT_LIB
Snapshot daemon filer operations library.
FREESPACEMONITOR
Free Space Monitor.
FT_CIFS_SHIM_LIB
FT_CLI
FTD
GBL_LIB
GBL_SVCMGR
Interface to metadata storage on CIFS filers. Metadata is information
about files and directories in managed volumes, such as their locations
on back-end filers.
File Tracking CLI. These are the CLI operations for setting up a
file-history archive and using it to track the location of managed-volume
files over time.
File Tracking daemon. This is the process of sending volume metadata
and configuration to an external file-history archive, and using that
archive to track the location of managed-volume files over time.
Global Services Library, for NFS and CIFS service management
operations.
Global Service Manager, which starts and stops NFS and CIFS front-end
services.
GBLSVC_CLI
Global Service CLI.
GUI
Graphical User Interface (GUI), also known as the ARX Manager.
HA_CLI
High Availability CLI, such as the 'redundancy' command.
CLI Maintenance Guide
8 - 11
Chapter 8
Troubleshooting Tools
Log Component
HWAGENT
IPC_EVENT_LIB
IPC_EVENT_MGR
IPC_LIB
IPCMOND
IPMIUTIL
KRBCONFD
KRBDDNS
L2SW_DRV
L2SW_LVL7
LIBCIFS
LIBCIFSAUTH
Description
Hardware Agent, for startup, shutdown, and monitoring of hardware
components.
IPC Event Library, for communication between internal ARX processes.
This is deprecated, so it is unlikely to yield any log messages.
IPC Event Manager, for communication between internal ARX
processes.
Internal software inter-process messaging library.
IPC service monitoring daemon, for monitoring the communication
between internal ARX processes.
ipmiutil event collector. All log levels for this logging component go to the
kernel.log file, not syslog.
Active Directory (AD) Configuration Daemon, for periodically monitoring
DCs and selecting the active DCs for each Windows domain.
Dynamic DNS registration helper. This registers dynamic-DNS aliases
for an ARX-CIFS service with a remote DNS server.
Layer2 - Internal Switch Hardware. This only applies to ARX-500,
ARX-2000, and ARX-4000 systems.
Layer2 - Internal Switch Software. This controls packet traffic over
network interfaces, channel traffic and LACP, spanning-tree, and other
low-level networking. This only applies to ARX-500, ARX-2000, and
ARX-4000 systems.
CIFS client library, used for non-client access to CIFS file servers. For
example, this library is used for policy-invoked migrations.
CIFS authentication library, for authenticating front-end CIFS clients and
internal ARX processes that access back-end filers.
LIBCIFSEXT
CIFS utility library, used in conjunction with LIBCIFS.
LIBEXIM
Exim Utilities messages.
LIBKDCLBSTATS
Kerberos load-balancing statistics.
LIBSDDL
LIBXSD
LICENSE
LIP_LIB
CIFS Security Descriptor Definition Language translation library, which
transforms binary Security IDs (SIDs) and descriptors into text strings.
Callers to this library include the SID_CACHE, POLICY_SHADOW, and
SUBSHRMGT processes.
CIFS security-descriptor translation library, which processes can use to
access the SID_CACHE daemon. The SID_CACHE daemon translates
between Security IDs (SIDs) on various file servers and the group/user
names in a Windows domain.
License monitoring daemon and CLI.
Logical IP Address Library. A logical IP address is an internal address
that processes use to communicate to one another.
LOCBROKERD
IPC Location Broker for internal (process-to-process) RPC requests.
LOGMGRD
Logging Manager Daemon.
MANUF
Manufacturing Purposes only - Internal Switch Software.
MERGED
Layer2 - Merge FPGA Daemon.
MGMT_CLI
Management SLM - not supported.
8 - 12
Accessing the Syslog
Log Component
MGT_DNAS_CONFIG
MGT_RON_RTMD
MGT_SVC_AGENT
MGT_SVCMGR
MLBD
MS_CLIENT
MS_RPC
MTLDAEMON
Description
DNAS Configuration. DNAS, or Distributed NAS, is the internal name for
namespace software.
Route Table Control Daemon. This checks gateway health and loads the
best available routes into the OS route tables.
Service Agent, which acts as a local agent for the central Service
Manager (MGT_SVCMGR) process.
Service Manager, used to start (and possibly restart) ARX processes.
Metalog Block Device (MLBD) Controller, which manages the internal
metalog subsystem. The metalog subsystem stores
database-transaction logs for managed volumes.
Microsoft RPC Services - High-level library used to interact with CIFS
filers.
Microsoft RPC Library - Low-level library used to interact with CIFS filers.
Metalog Daemon. This is the process that records metalog
(namespace-recovery log) data, on the local NVRAM hardware. This
only runs on the ARX-500, ARX-2000, and ARX-4000.
NET
Network, or data-plane, processes.
NET_APP
Miscellaneous Application Events in the network software.
NET_CIFS
NSM CIFS Proxy.
NET_ERR_TRAP
Fastpath resource errors.
NET_HA
NSM HA.
NET_IPC_PROXY
NSM IPC Proxy, for communication between internal ARX processes on
the control plane and on the data plane.
NET_LOG_PROXY
NSM Log Proxy.
NET_MSG
NSM Messaging between network processes.
NET_NFS
NSM NFS Proxy.
NET_OS
NSM Embedded Operating System.
NET_SLB
Server Load Balancing in the network software - not supported.
NET_STATS
NSM Statistics Collection.
NET_TCPSP
TCP Splicing.
NETBIOS
Netbios name service, which supports WINS.
NETSNMP
SNMP management on ARX-1500 and ARX-2500.
NFSCONFD
NFS Configuration Daemon, which manages one front-end NFS service.
NISD
NLA
NLM
NMPIPE
CLI Maintenance Guide
NIS daemon messages. NIS servers provide a lookup service for NFS
servers, to manage large NFS access lists. The NIS daemon queries all
the configured NIS servers and caches the results of those lookups.
NETLOGON Agent, supports NTLM authentication of CIFS clients, but
only for ARX CIFS services configured for constrained delegation.
NFS Network Lock Manager (NLM) Daemon. This implements the NFS
NLM protocol, which manages file locks for NFS clients.
Named Pipe, for communication between internal ARX processes
(MS-RPC operations on CIFS IPC$ named pipes).
8 - 13
Chapter 8
Troubleshooting Tools
Log Component
NSCK
Description
DNAS Namespace Check (NSCK), for examining and repairing
managed-volume metadata. Metadata is managed-volume information
about its files and directories, such as locations on back-end filers.
NSCKRPT
NSCK Report Messages.
NSM
NSM Shared Memory.
NSM_RON
NSM RON.
NTLMAGENTAPI
NTLM/NTLMv2 authentication library using ARX Secure Agent.
NTP
NVRDAEMON
Network Time Protocol (NTP) subsystem to keep the ARX clock(s)
synchronized with an external clock on the IP network.
Non Volatile RAM (NVRAM) Daemon, which manages one or more
mtlDaemons (see MTLDAEMON). An mtlDaemon records metalog
(namespace-recovery log) data, on the local NVRAM hardware. This
only runs on the ARX-500, ARX-2000, and ARX-4000.
OBJ_MGR
Object Manager Database.
OBJ_MGR_LIB
Object Manager Library.
OM
OMIO
OMTT
PERSONALITY
POLICY
POLICY_ACTION
POLICY_CLI
POLICY_PDP
POLICY_PEP
POLICY_SHADOW
Object Manager (Distributed Database) process. This is for the internal
database, which stores the ARX configuration. You can see the full
configuration with 'show running-config' and 'show global-config'.
Object Manager Record I/O Tracing. This tracing is for the internal
database, which stores the ARX configuration. (You can see the full
ARX configuration with 'show running-config' and 'show global-config.').
Object Manager Transaction Tracing. This tracing is for the internal
database, which stores the ARX configuration. (You can see the full
ARX configuration with 'show running-config' and 'show global-config.').
Personality, which parses XML data transferred between internal
processes.
not supported.
Migration requests and responses. You can use this to diagnose
migration issues, such as file matching and mismatching.
not supported.
Policy Decision Point - policy scheduler, which uses schedule
configuration to trigger scans and other policy events.
Policy Enforcement Point - policy scanning, events, rule-state
processing, and rule info.
Policy Shadow Volume, a read-only volume that contains replicas of all
the files and directories on another volume.
PROBE
Probes for Monitoring and Controlling Subsystems.
PTW
Parallel Treewalk Library.
RELMGR
RELMGR_CLI
REMOTE_CLI
8 - 14
Release Manager, which stores software-release (.rel) files, unpacks
them, prepares them for use on the ARX, and otherwise manages them.
Release Manager CLI commands. This is deprecated, so it is unlikely to
yield any log messages.
Remote SSH CLI command execution, invoked through the CLI (with the
'rconsole' command) or the GUI.
Accessing the Syslog
Log Component
Description
REPLMGR
Replication Manager - Directs Data-Mover Engine (DME) file-migrations.
REPORT
Common subsystem for generating and viewing reports.
RESTARTDETECT
This determines if internal processes can be restarted after a failure.
RON
Resilient Overlay Network (RON) CLI operations.
RON_SPFD
RON_VPND
ROOTD
Resilient Overlay Network (RON) Routing Daemon. This manages RON
tunnels and determines the best route to remote ARX devices.
Not supported.
Root Daemon, which performs internal Unix management that requires
root-level privileges.
SCM_DSMD
DNAS Switch Monitor.
SEC_CONFIG
Security Configuration.
SEC_LOCAL
Security Local Enforcement.
SECURITY_CLI
Security CLI.
SECURITYD
Security Daemon.
SHMEM
SHRTOP
SID_CACHE
Common, shared, memory-management subsystem. This is primarily
used for gathering statistics.
Share topology library - Used for various filer-subshare computations.
Security descriptor translation daemon (XSDD) and its caches. XSDD
translates between Security IDs (SIDs) on various file servers and the
principal (group or user) names in a Windows domain.
SLMCONFD
SLM Configuration Daemon - not supported.
SMGMT
Storage Management Library.
SMTP
SNAPD
SQMD
SSB_LIB
SSBEVENTD
SSH
SSRM
STATSD
STATSMON
SUBSHRMGT
CLI Maintenance Guide
Used for file transfer (through email), email events, and other
email-related features.
Snapshot daemon, which coordinates snapshots on multiple filers behind
an ARX volume.
Redundant Pair Site Quorum Manager, which makes failover decisions
based on cluster integrity.
SSB Library. The SSB is an internal mechanism for processes to
communicate with one another.
SSB Event Daemon. The SSB is an internal mechanism for processes
to communicate with one another.
SSH configuration.
Simple Share Resource Monitor, which monitors filers on behalf of the
HA subsystem.
Statistics Daemon, which exposes all ARX statistics to SNMP, the CLI,
and the ARX manager (GUI).
Statistics monitoring.
Subshare management daemon and its client library. This manages filer
subshares. A filer subshare is any CIFS share that is inside another
CIFS share.
8 - 15
Chapter 8
Troubleshooting Tools
Log Component
SVCMGR_LIB
SYNC_CLOCK
SYNC_LIB
SYSLOG_NG_GUARD
TASK_LIB
Description
SvcMgr Client Library. This is deprecated, so it is unlikely to yield any
log messages.
Log messages related to sync_clock and sntpc on ASMs - not supported.
Shadow Synchronization Library, which supports a shadow volume (see
POLICY_SHADOW).
syslog-ng_guard, which monitors and (if necessary) reanimates the
syslog-ng process. The syslog-ng process maintains the syslog file,
possibly duplicating it to a remote peer.
Task Dispatcher Library - Internal framework used by internal processes
for managing event-driven tasks and scheduled tasks.
TCMD
NSM Configuration Manager.
TCORED
NSM Core Dump Manager.
TIME
Not supported.
TRANFS
Transitional File System in DNAS.
TRANFSD
Not supported.
TXNMOND
UTIL
VCIFS
WDOG
WMA
WMI
Object Manager Transaction Monitor. This monitors the internal
database, which stores the ARX configuration. (You can see the full
ARX configuration with 'show running-config' and 'show global-config.').
Fast Filter IPC Utilities, for communication between internal ARX
processes and the Chassis Manager (see CHASS).
dNAS CIFS Proxy, which handles requests to volume software on behalf
of CIFS clients.
Watchdog, which performs internal health checks on ARX hardware such
as the SSB. The SSB is an internal mechanism for processes to
communicate with one another.
Windows Management Authorization (WMA) CLI Commands and
Library.
Software Library for managing snapshots on back-end Windows servers
using Windows Remote Management protocol (WinRM) and Windows
Management Instrumentation (WMI).
Syslog Syntax
Each line in the syslog uses the following syntax:
utc.uuu‐tz:switch:slot‐proc‐board‐pid:cmp‐ins‐sev‐id:: msg
For example,
2009‐05‐13T11:05:44.202+0000:bstnA:1‐1‐SCM‐29776:CLI‐0‐NOTE‐CLI_COMMAND:: User admin: Command: bstnA# show nsck
Where
• utc (2009‐05‐13T11:05:44 in the example) is the time in UTC.
8 - 16
Accessing the Syslog
• uuu (202) is the millisecond time fraction.
• -tz (+0000) is the hours off UTC (+nnnn or -nnnn).
• switch (bstnA) is the switch name.
• slot-proc-board (1‐1‐SCM) is the chassis slot, processor number, and
board type (ACM, ASM, SCM, or NSM). Use the show processors
command for a list of all processors and their associated modules.
• pid (29776) is the Process ID (PID).
• cmp (CLI) is the log-component name. Refer to Log Components, above.
• ins (0) is the process’s instance number.
• sev (NOTE) indicates the message severity: DBG (debug) is the least
severe, followed by INFO, NOTE, WARN, ERR, and CRIT (critical).
• id (CLI_COMMAND) is the message-catalog ID, a unique ID for each log
message. MSGn is an ID for an uncatologued message. The n is the
severity of the message, from 7 (debug) down to 2 (critical). Refer to the
ARX Log Catalog for an alphabetical list of log messages, sorted by their
IDs. To view the documentation for a specific message, use the show
documentation command (described later in the chapter).
• msg (User admin: Command: bstnA# show nsck) is the message
text itself.
Reading IDs for Namespaces, Volumes, and Shares
Syslog messages identify namespaces, volumes, and shares with numeric
IDs. The syslog also uses numeric IDs to identify its file-history archives
(recall Creating a File-History Archive, on page 3-6). To correlate these IDs
with the names used in the CLI, use the show id-mappings command:
show id‐mappings
For example:
bstnA(cfg)# show id‐mappings
Namespace ID
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐
medco 1
wwmed 2
medarcv 3
insur 4
Volume Namespace ID
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐
/vol medco 1
/acct wwmed 2
/rcrds medarcv 3
/lab_equipment medarcv 4
/test_results medarcv 5
/claims insur 7
Share Volume Namespace ID
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐
corporate /vol medco 1
sales /vol medco 2
CLI Maintenance Guide
8 - 17
Chapter 8
Troubleshooting Tools
generic /vol medco 3
budget /acct wwmed 5
bills /acct wwmed 6
bills2 /acct wwmed 7
it5 /acct wwmed 8
metadata‐share /acct wwmed 4
rx /rcrds medarcv 11
charts /rcrds medarcv 12
bulk /rcrds medarcv 13
metadata‐share /rcrds medarcv 10
equip /lab_equipment medarcv 15
leased /lab_equipment medarcv 16
backlots /lab_equipment medarcv 17
scanners /lab_equipment medarcv 18
metadata‐share /lab_equipment medarcv 14
chemistry /test_results medarcv 19
hematology /test_results medarcv 20
shr1‐old /claims insur 25
shr1‐next /claims insur 26
metadata‐share /claims insur 24
Archive Name ID
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐
fileRecordsMed 23
bstnA(cfg)# ...
Paging Through the Syslog (show logs)
Use the show logs command to page through the active syslog or one of the
syslog backups:
show logs file‐name
where file-name (1-1024 characters) is the name of the desired syslog
file.
You can then use <Space> to step through the file one page at a time. Press
q to quit out of the file.
For example, this command shows the contents of the active syslog:
bstnA(cfg)# show logs syslog
2009‐05‐13T15:42:45.492+0000:bstnA:1‐1‐SCM‐4445:BESPD‐0‐NOTE‐SHARE_AVAILABLE:: Storage Transition: [192.168.25.28] path [hematology_results] id [20] (Status now available)
2009‐05‐13T15:42:45.825+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
2009‐05‐13T15:42:54.234+0000:bstnA:1‐1‐SCM‐3570:CRMD‐0‐WARN‐CRMD_NO_MSHIP:: Cannot obtain a valid HA membership [[ep:0,<>]]
2009‐05‐13T15:43:23.334+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: policyRuleShareFrequencyZeroClear (528) nsp 'medarcv', vol '/rcrds', shr 'charts', nfp rule 'medFm', : Share frequency is non‐zero
2009‐05‐13T15:43:39.960+0000:bstnA:3‐2‐ASM_FC‐1873:TRANFS‐3‐WARN‐MSG4:: get_space failed at \\192.168.25.28\hematology_results ‐ STATUS_TRANSACTION_TIMED_OUT
2009‐05‐13T15:43:52.492+0000:bstnA:1‐1‐SCM‐4444:BESPD‐0‐NOTE‐SHARE_UNAVAILABLE:: Storage Transition: [192.168.25.28] path [hematology_results] id [20] (Status now unavailable); 4 probes failed over 30 seconds (durations: 15s 15s 0.1ms 0.0ms); Last probe status: [STATUS_BAD_NETWORK_PATH]
2009‐05‐13T15:43:52.826+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOffline (670) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
8 - 18
Accessing the Syslog
2009‐05‐13T15:43:54.270+0000:bstnA:1‐1‐SCM‐3570:CRMD‐0‐WARN‐CRMD_NO_MSHIP:: Cannot obtain a valid HA membership [[ep:0,<>]]
2009‐05‐13T15:44:14.143+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: policyRuleSourceUnavailable (533) nsp 'medarcv', vol '/rcrds', nfp rule 'medFm', : Source unavailable
2009‐05‐13T15:44:14.152+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: policyRuleShareFrequencyZeroRaise (529) nsp 'medarcv', vol '/rcrds', shr 'charts', nfp rule 'medFm', : Share frequency is zero
2009‐05‐13T15:44:51.542+0000:bstnA:1‐1‐SCM‐4445:BESPD‐0‐NOTE‐SHARE_AVAILABLE:: Storage Transition: [192.168.25.28] path [hematology_results] id [20] (Status now available)
2009‐05‐13T15:44:51.859+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
‐‐MORE‐‐
Searching Through the Syslog
Use the grep command to apply a regular expression to the syslog as you
page through it, viewing only the lines that contain a desired string:
grep pattern logs [file‐name]
where
pattern (1-255 characters) is the regular-expression pattern to
search for in the syslog. The grep displays all lines containing this
pattern.
The regular expression syntax follows grep’s “basic”
regular-expression syntax:
•
. matches any single character.
•
.* matches any string, including the null string.
•
[...] matches any one of the enclosed characters.
•
[a-z] matches any character in the sorted range, a through z.
•
\ matches the next character, even if it has special meaning (for
example, \. matches a period instead of any character).
•
[^...] matches any character that is not enclosed. For example,
[^0-9] matches any single character that is not a number from
0 to 9.
logs is a required keyword; this specifies the “logs” directory,
where the syslogs are stored.
file-name (optional, 1-255 characters) identifies one file to search.
If you omit the file name, the CLI searches through all files in the
logs directory. Use the show logs command to see a list of
accessible log files.
For example, the following command searches the active syslog for the
string, “shareOnline:”
bstnA(cfg)# grep shareOnline logs syslog
2009‐05‐13T10:36:51.150+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medco:/vol:corporate', name 'nas1', ip '192.168.25.21',
2009‐05‐13T10:36:51.175+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medco:/vol:sales', name 'nas2', ip '192.168.25.44',
CLI Maintenance Guide
8 - 19
Chapter 8
Troubleshooting Tools
2009‐05‐13T10:36:51.199+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medco:/vol:generic', name 'nas3', ip '192.168.25.47',
2009‐05‐13T10:37:33.335+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'wwmed:/acct:budget', name 'das1', ip '192.168.25.19',
2009‐05‐13T10:37:33.414+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'wwmed:/acct:bills', name 'das8', ip '192.168.25.25',
2009‐05‐13T10:37:33.468+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'wwmed:/acct:bills2', name 'das3', ip '192.168.25.22',
2009‐05‐13T10:37:33.522+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'wwmed:/acct:it5', name 'das7', ip '192.168.25.24',
2009‐05‐13T10:39:04.019+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/rcrds:rx', name 'fs4', ip '192.168.25.29',
2009‐05‐13T10:39:04.122+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/rcrds:charts', name 'fs1', ip '192.168.25.20',
‐‐MORE‐‐
Filtering Messages Out
You can use the ignore flag to filter out a second string from the grep output:
grep pattern logs [file‐name] ignore ignore‐pattern
where
pattern, logs, and file-name are described above,
ignore is required, and
ignore-pattern (1-1024 characters) is a pattern to ignore. Surround
this with quotes (“”) if it contains any spaces.
For example, the following command sequence repeats the above example
but ignores all messages containing the “acct” string:
bstnA(gbl)# grep shareOnline logs syslog ignore acct
2009‐05‐13T10:36:51.150+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medco:/vol:corporate', name 'nas1', ip '192.168.25.21',
2009‐05‐13T10:36:51.175+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medco:/vol:sales', name 'nas2', ip '192.168.25.44',
2009‐05‐13T10:36:51.199+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medco:/vol:generic', name 'nas3', ip '192.168.25.47',
2009‐05‐13T10:39:04.019+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/rcrds:rx', name 'fs4', ip '192.168.25.29',
2009‐05‐13T10:39:04.122+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/rcrds:charts', name 'fs1', ip '192.168.25.20',
2009‐05‐13T10:39:04.222+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/rcrds:bulk', name 'fs2', ip '192.168.25.27',
2009‐05‐13T10:39:14.632+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/lab_equipment:equip', name 'nas10', ip '192.168.25.49',
2009‐05‐13T10:39:15.084+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/lab_equipment:leased', name 'nas10', ip '192.168.25.49',
2009‐05‐13T10:39:15.286+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/lab_equipment:backlots', name 'fs2', ip '192.168.25.27',
2009‐05‐13T10:39:15.457+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/lab_equipment:scanners', name 'fs5', ip '192.168.25.71',
2009‐05‐13T10:39:15.508+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:chemistry', name 'fs1', ip '192.168.25.20',
2009‐05‐13T10:39:15.560+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
2009‐05‐13T10:39:24.245+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:2005_charts', name '[medarcv]',
2009‐05‐13T10:55:18.850+0000:bstnA:1‐1‐SCM‐2138:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'insur:/claims:shr1‐old', name 'nas1', ip '192.168.25.21',
8 - 20
Accessing the Syslog
...
bstnA(gbl)#
Searching the End of the Syslog
The show and grep commands search from the beginning of the syslog file,
starting with the oldest messages and moving toward the most-recent logs.
To skip ahead to the most-recent logs, use the tail option at the end of the
grep command:
grep pattern logs [file‐name] [ignore ignore‐pattern] tail number‐lines
where
pattern, logs, file-name, and ignore ignore-pattern are described
above,
tail is required, and
number-lines (1-4096) is the number of lines to show.
For example, the following grep command shows only the 10 most-recent
matching lines in the active syslog:
bstnA(gbl)# grep shareOnline logs syslog tail 10
2009‐05‐13T13:15:30.519+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/rcrds:rx', name 'fs4', ip '192.168.25.29',
2009‐05‐13T13:41:01.761+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
2009‐05‐13T13:51:41.818+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
2009‐05‐13T14:22:31.470+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
2009‐05‐13T14:39:45.403+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/rcrds:rx', name 'fs4', ip '192.168.25.28',
2009‐05‐13T15:42:45.825+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
2009‐05‐13T15:44:51.859+0000:bstnA:1‐1‐SCM‐2141:L2SW_LVL7‐0‐NOTE‐MSG5:: SNMP TRAP: shareOnline (680) shr 'medarcv:/test_results:hematology', name 'fs3', ip '192.168.25.28',
2009‐05‐13T16:10:39.029+0000:bstnA:1‐1‐SCM‐29206:CLI‐0‐NOTE‐CLI_COMMAND:: User admin: Command: bstnA> grep shareOnline logs syslog
2009‐05‐13T16:14:10.839+0000:bstnA:1‐1‐SCM‐29206:CLI‐0‐NOTE‐CLI_COMMAND:: User admin: Command: bstnA> grep shareOnline logs syslog ignore acct
2009‐05‐13T16:17:57.262+0000:bstnA:1‐1‐SCM‐29206:CLI‐0‐NOTE‐CLI_COMMAND:: User admin: Command: bstnA> grep shareOnline logs syslog tail 10
bstnA(gbl)#
Showing the Documentation for a Syslog Message
Many syslog messages (as well as messages from the CLI) have
more-verbose documentation associated with them; you can access this
additional documentation from the CLI. From any mode, use the show
documentation command to view the documentation for a given message:
show documentation msg‐catalog‐id
CLI Maintenance Guide
8 - 21
Chapter 8
Troubleshooting Tools
where msg-catalog-id (1-255 characters) identifies the message. This
ID appears with the message in both the syslog (recall the id field in
each syslog message; see Syslog Syntax, on page 8-16) and in CLI
output.
For example, the following command sequence shows a syslog message,
then shows the documentation for it:
bstnA(gbl)# grep RON_SPFD logs syslog
2009‐05‐13T11:34:10.620+0000:bstnA:1‐1‐SCM‐3558:RON_SPFD‐0‐NOTE‐RON_SYSTEM_CLOCK_CHANGED:: System clock changed, adjusting schedule by 0 seconds, 131744 microseconds.
bstnA(gbl)# show documentation RON_SYSTEM_CLOCK_CHANGED
RON_SYSTEM_CLOCK_CHANGED documentation:
The RON Shortest Path First Daemon has adjusted its internal schedule in response to a system clock change.
bstnA(gbl)# ...
Copying the Syslog File to an FTP Server
You can save the syslog file off to a remote FTP server for further analysis.
From priv-exec mode, use the copy logs command and specify the FTP
server in a destination URL:
copy logs syslog‐file ftp://[username:password@]ftp‐site/file
where
syslog-file identifies the syslog file to copy,
username:password@ (optional) is an FTP username and
password (the default is set by the ip ftp-user command, as shown
in Setting a Default FTP or SCP User, on page 5-3),
ftp-site identifies the FTP server with an IP address or FQDN (for
example, “172.16.88.3” or “ftp.myftpsite.com”), and
file is the chosen file name. Lead with an extra “/” if the path starts
at the root of the server machine; for example,
“porthos//var/log/arx/syslog” specifies “/var/log/arx/syslog” on
server porthos. Omit the leading slash if the file is going to the
home directory for username.
For example, the following command exits from cfg mode to priv-exec
mode, then copies the active-syslog file to a remote server:
bstnA(cfg)# exit
bstnA# copy logs syslog ftp://juser:jpasswd@ftp.wwmed.com/syslog_5‐6
bstnA# ...
Copying the Syslog File through SCP
For secure sites, you can upload with the Secure Copy (SCP) protocol. The
URL has a different syntax for SCP transfers:
copy logs syslog‐file scp://username@server:file [accept‐host‐key]
where
8 - 22
Accessing the Syslog
syslog-file identifies the syslog file to copy,
username@ is a valid username at the remote host,
server identifies the SCP server with an IP address or FQDN (for
example, “172.16.100.18” or “deb1.mynet.com”), and
file is the chosen file name at the remote server. Lead with a slash
(scp-server:/file) if the file path is absolute. Without the slash, the
path is presumed to start in the home directory for username.
accept-host-key (optional) tells the CLI to accept an unknown host
key if offered by the SCP server. The host key authenticates the
server; if the key is unknown, it is possible that an attacker has
taken the server’s hostname and/or IP address. Note that any SCP
server is “unknown” if the switch has not had an SCP exchange
with it since the switch’s last reboot.
The CLI prompts for the username’s password. Enter a password that is
valid at the remote site.
For example, the following command exits from cfg mode to priv-exec
mode, then sends the “syslog” file to juser’s home directory on
rh1.wwmed.com:
bstnA(cfg)# exit
bstnA# copy logs syslog scp://juser@rh1.wwmed.com:arx_syslog
Password: jpasswd
bstnA# ...
Copying the Syslog File into an ARX Volume
For sites that do not support FTP or SCP, you can copy the syslog file to an
ARX volume:
copy logs syslog‐file {cifs|nfs} namespace volume file‐path
where
syslog-file identifies the syslog file to copy,
cifs | nfs is a required choice. This is the network protocol used to
copy the syslog file into the ARX volume.
namespace (1-30 characters) identifies the destination namespace.
volume (1-1024 characters) is the volume name.
file-path (1-1024 characters) is the path from the volume root
(above) to the destination file.
For example, the following command exits from cfg mode to priv-exec
mode, then sends the “syslog” file to a directory in the “medarcv~/rcrds”
volume:
bstnA(cfg)# exit
bstnA# copy logs syslog cifs medarcv /rcrds admin
bstnA# ...
CLI Maintenance Guide
8 - 23
Chapter 8
Troubleshooting Tools
Sending the Syslog File to an E-Mail Recipient
You can alternatively send the syslog file as an E-mail attachment. Before
you use E-mail, you must configure the Simple Mail Transfer Protocol
(SMTP) on the switch, starting with the smtp command in cfg mode: see the
chapter on E-mail and SMTP in the ARX® CLI Reference.
Use the following syntax to send the syslog file in an E-mail message:
copy logs syslog‐file smtp://[e‐mail‐address/]file
where
e-mail-address (optional) identifies the recipient of the E-mail
message (for example, “myCoWorker@myco.com”). If you omit
this, it defaults to the E-mail recipient set with the cfg-smtp to
command. Use a slash (/) to separate this from the file name.
file is the chosen file name.
For example, the following command sequence sets up SMTP, exits from
cfg mode to priv-exec mode, then mails the “syslog” file to
“juser@wwmed.com:”
bstnA(cfg)# smtp
bstnA(cfg‐smtp)# mail‐server email1.wwmed.com
bstnA(cfg‐smtp)# from admin@acopia.wwmed.com
bstnA(cfg‐smtp)# exit
bstnA(cfg)# exit
bstnA# copy logs syslog smtp://juser@wwmed.com/arx_syslog
bstnA# ...
Adjusting Logging Levels
Each log component has a logging level that determines the volume of logs
that it generates. You can set a different logging level for every log
component, allowing you to focus attention on a single component or a
small group of them.
From cfg mode, use the logging level command to change the logging level
for one (or all) log components:
logging level component {critical | error | warning | notice | info | debug}
where
component can be all or any log component (see Log Components,
on page 8-9), and
critical | error | warning | notice | info | debug chooses the
logging level for the component. The critical level limits the
component to critical log messages only, error allows both error
and critical messages, and so on. Debug level is the most verbose;
this causes the component(s) to issue every possible log message
during their execution.
For example, the following command sets the logging level to debug
(most-verbose) for the TRANFS component:
8 - 24
Accessing the Syslog
bstnA(cfg)# logging level TRANFS debug
bstnA(cfg)# ...
Disabling Log Messages
You can stop all log messages from a given component, or for all
components. Use the disable keyword at the end of the logging level
command:
logging level component disable
where
component can be all or any log component (see Log Components,
on page 8-9), and
disable stops all logging from the component.
For example, the following command disables logging from the
POLICY_PDP component:
bstnA(cfg)# logging level POLICY_PDP disable
bstnA(cfg)# ...
Showing All Log Components and Levels
Use the show logging levels command to see the logging levels for all log
components:
show logging levels
The output is a table where the X next to each log component marks its
logging level. If the APP_RON_RTMD component has an X in the
“warning” column, for example, the APP_RON_RTMD is set to the
“warning” logging level.
All of the log components shown in the example below are set to “notice”
logging level:
bstnA(cfg)# show logging levels
Configured Log Levels:
disable debug info notice warning error critical
AFN_NET | | | | X | | | | APP_RON_RTMD | | | | X | | | | AUTH_CONSOLE | | | | X | | | | AUTH_HTTP | | | | X | | | | AUTH_HTTPS | | | | X | | | | AUTH_SSH | | | | X | | | | AUTH_TELNET | | | | X | | | | BOOTPD | | | | X | | | | CHASS | | | | X | | | | CHASS_LIB | | | | X | | | | CIFSCLI | | | | X | | | | CIFSCONFD | | | | X | | | | CIFS_INIT | | | | X | | | | CIFS_SHIM_LIB | | | | X | | | | CLI | | | | X | | | | CLI_WIZARD | | | | X | | | | CLUSTER | | | | X | | | | COMMONLIB | | | | X | | | | CLI Maintenance Guide
8 - 25
Chapter 8
Troubleshooting Tools
...
Focusing on One Logging Level
You can specify a particular log component to show its current logging
level:
show logging levels component
where component can be all or any log component (see Log
Components, on page 8-9).
The output is one row from the table shown above. For example, the
following command shows the logging level for the “POLICY” component:
bstnA(cfg)# show logging levels POLICY
Configured Log Levels:
disable debug info notice warning error critical
POLICY | | | | X | | | | bstnA(cfg)# ...
Reverting Back to the Default Logging Level
The default logging level for all components is “info.” Use no logging level
to revert to the default logging level:
no logging level {component | all}
where you must choose either a single component or all components.
Refer to Log Components, on page 8-9 for a complete list of
components.
For example, the following command sequence reverts all components to
the default logging level, info. To prevent the syslog from filling up too
quickly, you should do this after every examination of the syslog:
bstnA(cfg)# no logging level all
bstnA(cfg)# ...
8 - 26
Sending Logs to an External Server
Sending Logs to an External Server
You can configure the ARX to send its syslog messages to one or more
external servers. The external server receives log messages as they are
generated and appends them to its local syslog file.
From cfg mode, use the logging destination command to add a server to the
list of logging destinations:
logging destination target [udp | tcp] [port port]
where
target (1-80 characters) identifies an external server. This can be an
IP address or, if you have a DNS lookups configured, a hostname.
(To configure the switch for hostname lookups, see Configuring
DNS Lookups, on page 4-31 of the ARX® CLI
Network-Management Guide.)
udp | tcp (optional) chooses a transport protocol to reach the
external server. This defaults to UDP if you omit it.
port port (optional, 1-65,535) selects a particular UDP or TCP port
to receive the log messages. The default is port 514.
You can use this command multiple times to configure multiple destination
servers. For example, the following command sequence configures two
servers to receive syslog messages:
bstnA(cfg)# logging destination 172.16.202.8
bstnA(cfg)# logging destination 10.1.1.90 tcp port 9999
bstnA(cfg)# ...
Removing a Logging Destination
Use the no form of the logging destination command to remove one log
server from the list:
no logging destination target
where target (1-80 characters) identifies the server to remove. This can
be an IP address or a hostname.
For example:
bstnA(cfg)# no logging destination 10.1.1.90
bstnA(cfg)# ...
Sending Log Messages from a VLAN Interface (optional)
By default, the log messages come from the out-of-band management
interface (labeled MGMT on the switch’s front panel). You have the option
to change the source address to an in-band (VLAN) management interface,
instead: this uses the client/server ports. (For more information on in-band
management interfaces, see Configuring an In-Band (VLAN) Management
Interface, on page 4-4 of the ARX® CLI Network-Management Guide.)
CLI Maintenance Guide
8 - 27
Chapter 8
Troubleshooting Tools
From cfg mode, use the management source command to change the source
interface for outbound syslog messages:
management source vlan vlan‐id
where vlan-id (1-4096 characters) identifies the VLAN. Use show
interface vlan to list all configured VLANs and their management
interfaces (see Listing all VLAN Management Interfaces, on page 4-6 of
the ARX® CLI Network-Management Guide).
For example, the following command sequence uses the in-band
management interface for VLAN 25:
bstnA(cfg)# management source vlan 25
bstnA(cfg)# ...
Using the Out-of-Band Management Interface
To send syslog messages from the out-of-band management interface, the
default, use the no form of the management source command:
no management source
For example:
prtlndA(cfg)# no management source
prtlndA(cfg)# ...
The management source mgmt command has the same effect:
management source mgmt
For example:
bstnA(cfg)# management source mgmt
bstnA(cfg)# ...
Showing all Logging Destinations
To show all configured logging destinations, use show logging destination
from any mode:
show logging destination
For example:
bstnA(cfg)# show logging destination
Source Interface: mgmt (10.1.1.7) External Syslog Destination(s)
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
172.16.202.8 bstnA(cfg)# ...
8 - 28
Listing Current System Tasks
Listing Current System Tasks
The show system tasks command shows all running processes and the CPU
and memory that each process is consuming. This is similar to the ps
command on a Unix system, or the Task Manager on a Windows system.
Invoke this command from any mode:
show system tasks
The processes are listed in the “Subsystem” column. For example:
bstnA(cfg)# show system tasks
Subsystem Instance Memory (Kb) CPU%
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐
afnEmailHomed 1 6980 0
afnEximMgrd 1 6060 0
afnFTd 1 10252 0
afnFcnd 1 25644 0
afnFfpMgrd 1 5012 0
afnSlmConfd 1 13296 0
afncrmd 1 5412 0
afnipceventmgrd 1 5204 0
afnlicd 1 13260 0
afnloggermgrd 1 6392 0
afnmerged 1 4996 0
afnnetd 1 6596 0
afnpdpd 1 6636 0
afnrootd 1 9840 0
afnsnapd 1 13872 0
afnsqmd 1 10280 0
afnssbdevd 1 5772 0
afnssrmd 1 5964 0
afnstatsd 1 6916 0
apiLogFilter 1 2104 0
apiLogFilter 1 2112 0
apiLogger 1 2268 0
apiLogger 1 2112 0
apiLogger 1 2104 0
apiLogger 1 2108 0
apiLogger 1 2108 0
bespd 1 30888 0
bootpd 1 4932 0
chassnew 1 6536 0
cifsconfd 1 7804 0
cli_daemon 1 38000 0
coreCollector (script) 1 1728 0
coreTimer (script) 1 1680 0
...
tcmd 1 6408 0
tcored 1 4980 0
temipcproxyd 1 5080 0
temstatsd 1 6616 0
txnmond 1 7876 0
vg_launch (script) 1 1284 0
vg_launch (script) 1 1284 0
vg_launch (script) 1 1544 0
xsdd 1 7808 0
Other Tasks 36 173196 0
bstnA(cfg)# ...
CLI Maintenance Guide
8 - 29
Chapter 8
Troubleshooting Tools
Collecting Diagnostic Information
Some problems require thorough examination and diagnosis. To facilitate
this, the CLI has a command for collecting all interesting diagnostic
information on the ARX and sending it to a remote site. The diagnostic
information is a collection of very large files (including multiple core files),
so chose a destination server with plenty of free disk space.
From priv-exec mode, use the collect diag-info ftp command to collect all
diagnostic data (except reports, which can make the file excessively large)
and send it to an FTP site:
collect diag‐info ftp://[username[:password]@]ftp‐site/file.tgz
where
username[:password]@ (optional) is an FTP username and
optional password (the default is the username/password set by the
ip ftp-user command),
ftp-site identifies the FTP server with an IP address or FQDN (for
example, “172.16.88.3” or “ftp.myftpsite.com”), and
file.tgz is the chosen file name. Lead with an extra “/” if the path
starts at the root of the server machine; for example,
“athos//usr/local/diag_files.tgz” specifies “/usr/local/diag_files.tgz”
on server athos. Omit the leading slash if the file is going to the
home directory for username.
The CLI prompts for a password if you enter the username without one. The
CLI then prompts for confirmation before collecting the diagnostics.
Answer yes to continue. The collection process can be time-consuming;
prompts appear to show the progress of the operation as it occurs.
For example, the following command exits from cfg mode to priv-exec
mode, then sends diagnostic data to arxftp.f5.com:
bstnA(cfg)# exit
bstnA# collect diag‐info ftp://juser@arxftp.f5.com/acopia‐diags.tgz
Password: jpasswd
Collect diagnostic information? [yes/no] yes
% INFO: Completed CLI show information collection at 02/12/08 01:22:03.
% INFO: Completed log file collection at 02/12/08 01:22:03.
% INFO: Completed core file collection at 02/12/08 01:22:04.
% INFO: Completed state information at 02/12/08 01:23:33.
% INFO: Completed configuration information at 02/12/08 01:23:33.
% INFO: Preparing diagnostic file at 02/12/08 01:23:33.
% INFO: Collection complete at 02/12/08 01:24:02.
% INFO: The copy completed successfully.
bstnA# ...
Sending the Information Securely, through SCP
For secure sites, you can upload the diagnostic data with the Secure Copy
(SCP) protocol. The URL has a different syntax for SCP transfers:
collect diag‐info scp://username@server:file.tgz [accept‐host‐key]
8 - 30
Collecting Diagnostic Information
where
username@ is a valid username at the remote host,
server identifies the SCP server with an IP address or FQDN (for
example, “172.16.100.18” or “deb1.mynet.com”), and
file.tgz is the file name for the diagnostics data. Lead with a slash
(scp-server:/file) if the file path is absolute. Without the slash, the
path is presumed to start in the home directory for username.
accept-host-key (optional) tells the CLI to accept an unknown host
key if offered by the SCP server. The host key authenticates the
server; if the key is unknown, it is possible that an attacker has
taken the server’s hostname and/or IP address. Note that any SCP
server is “unknown” if the switch has not had an SCP exchange
with it since the switch’s last reboot.
The CLI prompts for the username’s password. Enter a password that is
valid at the remote site. Then the CLI prompts for confirmation before
collecting diagnostics; enter yes to continue. As mentioned above, you
should allow at least one minute for the collection process to complete.
For example, the following command exits from gbl mode to priv-exec
mode, then uploads diagnostic data through SCP:
bstnA(cfg)# exit
bstnA# collect diag‐info scp://juser@rh1.wwmed.com:acopia‐diags.tgz accept‐host‐key
Password: jpasswd
Collect diagnostic information? [yes/no] yes
% INFO: Completed CLI show information collection at 02/13/08 19:22:32.
% INFO: Completed log file collection at 02/13/08 19:22:32.
% INFO: Completed core file collection at 02/13/08 19:22:32.
% INFO: Completed state information at 02/13/08 19:23:24.
% INFO: Completed configuration information at 02/13/08 19:23:24.
% INFO: Preparing diagnostic file at 02/13/08 19:23:24.
% INFO: Collection complete at 02/13/08 19:23:56.
% INFO: The copy completed successfully.
bstnA# ...
Placing the Diagnostics File into an ARX Volume
Some sites do not allow any FTP access to their data centers, and do not
support SCP. For those sites, you can send the diagnostic data to a
client-accessible volume on the ARX. You can use the nfs or cifs clause to
send the output file to a given directory in a given volume:
collect diag‐info {cifs|nfs} namespace volume dest‐path
where
cifs | nfs is a required choice. This is the network protocol used to
transfer the diagnostics file to the ARX volume.
namespace (1-30 characters) identifies the destination namespace.
volume (1-1024 characters) is the destination-volume name.
CLI Maintenance Guide
8 - 31
Chapter 8
Troubleshooting Tools
dest-path (1-1024 characters) is the intended path from the volume
root (above) to the diagnostics file. The directory you specify here
must exist on the volume.
For example, the following command exits from gbl mode to priv-exec
mode, then uploads diagnostic data to the “medarcv~/rcrds” volume:
bstnA(cfg)# exit
bstnA# collect diag‐info cifs medarcv /rcrds admin/collect.tgz
Collect diagnostic information? [yes/no] yes
% INFO: Completed CLI show information collection at 04/30/2009 11:32:24 AM.
% INFO: Completed log file collection at 04/30/2009 11:32:25 AM.
% INFO: Completed core file collection at 04/30/2009 11:32:25 AM.
% INFO: Completed state information at 04/30/2009 11:33:54 AM.
% INFO: Completed configuration information at 04/30/2009 11:33:55 AM.
% INFO: Preparing diagnostic file at 04/30/2009 11:33:55 AM.
% INFO: Collection complete at 04/30/2009 11:34:52 AM.
% INFO: Copying 39 megabytes from the specified source . . .
% INFO: The copy source file 'collectDiagInfo.22837.tgz' to destination file 'collect.tgz' completed successfully.
bstnA# ...
Sending the Information in an E-Mail Message
You can alternatively send the diagnostics information as an E-mail
attachment. Before you use E-mail, you must configure the Simple Mail
Transfer Protocol (SMTP) on the switch, starting with the smtp command in
cfg mode: see the chapter on E-mail and SMTP in the ARX® CLI Reference.
In the same collect diag-info command, use the following syntax to send the
diag-info as an E-mail attachment:
collect diag‐info smtp://[e‐mail‐address/]file.tgz
where
e-mail-address (optional) identifies the recipient of the E-mail
message (for example, “myCoWorker@myco.com”). If you omit
this, it defaults to the E-mail recipient set with the cfg-smtp to
command. Use a slash (/) to separate this from the file name.
file.tgz is the chosen file name. The “.tgz” extension is required.
As with the FTP and SCP uploads, the CLI prompts for confirmation before
collecting the diagnostics. Answer yes to continue. The collection process
can be time-consuming; prompts appear to show the progress of the
operation as it occurs.
For example, the following command sequence sets up SMTP, exits from
cfg mode to priv-exec mode, then sends diagnostic data via E-mail to
“juser@wwmed.com:”
bstnA(cfg)# smtp
bstnA(cfg‐smtp)# mail‐server email1.wwmed.com
bstnA(cfg‐smtp)# from admin@acopia.wwmed.com
bstnA(cfg‐smtp)# exit
bstnA(cfg)# exit
bstnA# collect diag‐info smtp://juser@wwmed.com/acopia‐diags.tgz
8 - 32
Collecting Diagnostic Information
Collect diagnostic information? [yes/no] yes
% INFO: Completed CLI show information collection at 02/13/08 19:34:05.
% INFO: Completed log file collection at 02/13/08 19:34:05.
% INFO: Completed core file collection at 02/13/08 19:34:05.
% INFO: Completed state information at 02/13/08 19:35:13.
% INFO: Completed configuration information at 02/13/08 19:35:13.
% INFO: Preparing diagnostic file at 02/13/08 19:35:13.
% INFO: Collection complete at 02/13/08 19:35:45.
% INFO: Transferred 0 megabytes; still copying . . .
% INFO: The copy completed successfully.
bstnA# ...
Collecting the Information Locally
You have the option to store the diagnostic-information file on the switch’s
internal disks. To conserve disk space, you can only store one diag-info file
at a time.
collect diag‐info file.tgz
where file is the chosen file name. You must use a .tgz extension on the
end of the file name. The file is stored in the diag-info directory.
The CLI prompts for confirmation before overwriting any
previously-collected diag-info files. Answer yes to continue. As stated
above, the collection process can be time-consuming; allow at least one
minute for the collection process to finish.
For example, the following command exits from cfg mode to priv-exec
mode, then saves diagnostic data to a local file:
bstnA(cfg)# exit
bstnA# collect diag‐info juser‐ns‐wwmed.tgz
Only one copy of diagnostic information may be stored on the switch at one time.
This automatically deletes any saved diagnostic information.
Are you sure? [yes/no] yes
% INFO: Completed CLI show information collection at 02/13/08 19:39:03.
% INFO: Completed log file collection at 02/13/08 19:39:03.
% INFO: Completed core file collection at 02/13/08 19:39:03.
% INFO: Completed state information at 02/13/08 19:40:10.
% INFO: Completed configuration information at 02/13/08 19:40:10.
% INFO: Preparing diagnostic file at 02/13/08 19:40:10.
% INFO: Collection complete at 02/13/08 19:40:38.
% INFO: The copy completed successfully.
bstnA# ...
Showing the Diag-Info File
Use the show diag-info command to view the directory listing with the new
diag-info file:
show diag‐info
For example:
bstnA# show diag‐info
CLI Maintenance Guide
8 - 33
Chapter 8
Troubleshooting Tools
diag‐info
juser‐ns‐wwmed.tgz May 18 08:17 6.3M
bstnA# ...
Running the Collection Asynchronously
You can run the collection process in the background while you continue to
enter more CLI commands. To accomplish this, use the optional async
keyword before the URL:
collect diag‐info destination async
where
destination can be any of the formats defined above for FTP, SCP,
SMTP, an ARX volume, or a local file, and
async makes the collection process asynchronous.
The CLI prompts for confirmation; answer yes to continue. With the async
option, the CLI displays a report name and then returns. You can use the tail
reports report-name follow command to follow the collection process, or you
can enter other CLI commands.
For example, the following command exits from cfg mode to priv-exec
mode, then asynchronously collects and uploads diagnostic data:
bstnA(cfg)# exit
bstnA# collect diag‐info ftp://juser:jpasswd@arxftp.f5.com/acopia‐diags.tgz async
Collect diagnostic information? [yes/no] yes
Scheduling report: collect_diag_200711292228.rpt
bstnA# ...
Collecting Partial Information
You can choose from several optional keywords to expand or narrow the
focus of the collect command:
collect {diag‐info | config | cores | logs | reports | state | capture | all} destination [async]
where:
diag-info collects everything except reports, as described above.
config collects the configuration database, database logs, and the
output from show running/global config.
cores gathers any core-dump files on the system, along with all
shared-object libraries used by the system.
8 - 34
Collecting Diagnostic Information
logs assembles the syslog, the procdat log (process data; a
more-detailed log file for diagnosis by engineers), upgrade and
installation logs, disk-usage logs, Kerberos state files, and logs
from the system’s service manager.
reports chooses all reports. (As mentioned above, these are
omitted from the diag-info option because they can be excessively
large at some installations.)
state collects individual log files from every processor in the
switch, three system log files (syslog, procdat, and traplog), a
chronological list of all CLI commands used since the switch
booted, and the output from a series of useful show commands.
capture assembles all packet-capture files, which you can list with
the show capture command. You can use a CLI command to
capture IP traffic in a file for diagnostic purposes, as described in a
later chapter. This command can send the capture file(s) to F5 for
detailed examination.
all collects all information, including all reports. The diag-info
option omits reports because they can be excessively large on some
switches.
destination is either a local file name or any of the upload formats
described above.
async (optional) makes the collection process asynchronous.
As shown earlier, the CLI prompts for confirmation before collecting the
diagnostics. Answer yes to continue. The collection process can be
time-consuming, depending on system state and the option that you have
chosen; prompts appear to show the progress of the operation as it occurs.
For example, the following command exits from gbl mode to priv-exec
mode, then sends state information to arxftp.f5.com:
bstnA(cfg)# exit
bstnA# collect state ftp://arxftp.f5.com/sys‐state.tgz
Collect diagnostic information? [yes/no] yes
% INFO: Completed CLI show information collection at 02/13/08 19:52:57.
% INFO: Completed log file collection at 02/13/08 19:52:57.
% INFO: Completed state information at 02/13/08 19:54:12.
% INFO: Completed configuration information at 02/13/08 19:54:12.
% INFO: Preparing diagnostic file at 02/13/08 19:54:12.
% INFO: Collection complete at 02/13/08 19:54:21.
% INFO: The copy completed successfully.
bstnA# ...
Collecting Logs within a Time Frame
You can specify a time frame for log-file collection, so that the CLI collects
only the logs from a certain time. You can use this option to focus on an
eventful time period:
collect logs [start‐time start [utc]] [end‐time end [utc]] destination [async]
CLI Maintenance Guide
8 - 35
Chapter 8
Troubleshooting Tools
where you can choose a start and/or end time for the collected logs:
start-time start [utc] (optional) establishes a start time. If omitted,
the command collects all of its logs up to the end-time.
•
start is a date and time. Enter this in one of two formats:
mm/dd/yyyy:HH:MM:SS (designed for manual entry) or
yyyy-mm-ddTHH:MM:SS (the time format found in the log
files).
•
utc (optional) indicates that the start is UTC instead of local
time. Without this, the start is assumed to be in local time, as
established by the clock timezone command. This is intended
for a copy-and-paste from a log file. (All time stamps in the
log files are in UTC.)
end-time end [utc] (optional) establishes an end time for the
collected logs. If omitted, the command collects all of its logs after
the start-time. This has the same options as described above.
destination is either a local file name or any of the upload formats
described above.
async (optional) makes the collection process asynchronous.
As with a full collection, the CLI prompts for confirmation before collecting
the logs. Answer yes to continue. The collection process can be
time-consuming, depending on system state and the options that you have
chosen; allow at least one minute for the process to finish.
For example, the following commands collect logs from a specific
three-hour interval (9:30AM to 12:30PM on May 6, 2007) and send them
through E-mail:
bstnA(cfg)# exit
bstnA# collect logs start‐time 05/06/2008:09:30:00 end‐time 05/06/2008:12:30:00 smtp://juser@wwmed.com/mornLogs.tgz
Collect diagnostic information? [yes/no] yes
% INFO: Completed CLI show information collection at 05/06/08 20:09:50.
% INFO: Completed log file collection at 05/06/08 20:09:52.
% INFO: Completed configuration information at 05/06/08 20:09:52.
% INFO: Preparing diagnostic file at 05/06/08 20:09:52.
% INFO: Collection complete at 05/06/08 20:10:10.
% INFO: The copy completed successfully.
bstnA# ...
8 - 36
Setting Up Remote Monitoring By F5 Support
Setting Up Remote Monitoring By F5 Support
You can regularly send diagnostic information to F5 Support so that they
can monitor the health of your system, watching for any degradation in
resources and possibly stopping issues before they affect client service. F5
Support may also use this information to identify and eliminate performance
bottlenecks that may not be obvious. This information is encrypted and then
sent through SMTP as an E-mail attachment. The data-gathering,
encryption, and e-mailing process is done on a schedule. You set the
schedule (possibly along with some other options) as described in this
section.
Important
You must configure DNS and SMTP before you set up this data gathering
mechanism. For instructions on setting up DNS, refer to the ip name-server
command in the ARX® CLI Reference. For instructions on setting up SMTP,
refer to the smtp command in the same manual.
From gbl mode, use the auto-diagnostics command to begin configuring
the schedule for this regular data collection:
auto‐diagnostics
This places you in gbl-auto-diag mode, where you must set a schedule for
the data to be gathered, encrypted, and mailed. You also have some
additional options, such as adding more E-mail recipients for the gathered
data.
For example, the following command begins setting up auto diagnostics for
the "bstnA" switch:
bstnA(gbl)# auto‐diagnostics
bstnA(gbl‐auto‐diag)# ...
Auto diagnostics can be disabled using the no auto-diagnostics command,
which removes all in-memory and persistent database information about the
existing auto-diagnostics configuration.
Setting the Collection Schedule
The first step in setting up auto-diagnostic collection is assigning a schedule
for it. To create a schedule, use the gbl schedule command (refer to
Appendix 12, Creating a Policy Schedule of the ARX® CLI
Storage-Management Guide for details). To apply a schedule to auto-diag
collection, use the schedule command in gbl-auto-diag mode:
schedule name
where name (1-64 characters) identifies the schedule. Use the show
schedule command to list all schedules.
A schedule is required for auto-diagnostics to run. You can change to a new
schedule later by re-running the command.
CLI Maintenance Guide
8 - 37
Chapter 8
Troubleshooting Tools
For example, the following command sequence applies a schedule,
“daily4am,” to auto-diag collection:
bstnA(gbl)# auto‐diagnostics
bstnA(gbl‐auto‐diag)# schedule daily4am
bstnA(gbl‐auto‐diag)# ...
Adding Additional Show Commands to the Collection
By default, the auto-diagnostics collection operation collects the following
commands from the current ARX:
• show clock
• show chassis
• show processors
• show processors usage
• show health
• show version
• show running-config
• show global-config
• show ron
• show namespace all
• show arp all
• show redundancy all
• show cores
• show statistics namespace ... fastpath all fastpath
• show policy details
• show cifs-service user-sessions all summary
• show statistics cifs authentication all
• show active-directory status detailed
• show statistics filer detailed
• show external-filer all
You can use the additional-command operation to add more show
commands to this collection:
additional‐command "show‐command‐string"
where show-command-string is the additional show command
(128-byte limit) to add to the auto-diag collection. This command must
start with the keyword, "show," and must be accessible from any CLI
mode. Surround the string with quotation marks ("") if it contains any
spaces.
For example, the following command sequence adds two show commands
to auto-diag collection:
bstnA(gbl)# auto‐diagnostics
bstnA(gbl‐auto‐diag)# additional‐command "show global service"
bstnA(gbl‐auto‐diag)# additional‐command "show share status"
8 - 38
Setting Up Remote Monitoring By F5 Support
bstnA(gbl‐auto‐diag)# ...
On the backup switch, the default set of show commands is smaller, as it
omits global CLI commands. The default list of show commands supported
on the backup switch is:
•
show clock
•
show version
•
show chassis
•
show processors
•
show processors usage
•
show health
•
show running-config
•
show ron
•
show arp all
•
show redundancy all
•
show cores
Removing Additional Show Commands
Use the command no additional-command to remove a user-added show
command from future auto-diagnostic collections. This removes only the
specified additional command, not any of the default commands listed in the
previous section. The command syntax follows:
no additional‐command "show‐command‐string"
For example, this command sequence removes the extra show command
show share status from the auto-diagnostics collection at the "bstnA"
switch:
bstnA(gbl)# auto‐diagnostics
bstnA(gbl‐auto‐diag)# no additional‐command "show share status"
bstnA(gbl‐auto‐diag)# ...
Adding Additional E-mail Recipients
You can use the mail-to command to add additional recipients for the
collected E-mails. Unlike the collection for F5 Support, the E-mail
attachment for these recipients is not encrypted. The ARX encrypts the
collected information for F5 Support because it is likely to traverse the
Internet:
mail‐to recipient
where recipient is the E-mail address (128-byte limit) for someone to
receive the collected diagnostics.
For example, the following command sequence adds one E-mail recipient
(in addition to F5 Support) for auto-diag collections:
bstnA(gbl)# auto‐diagnostics
bstnA(gbl‐auto‐diag)# mail‐to juser@wwmed.com
bstnA(gbl‐auto‐diag)# mail‐to jsmith@wwmed.com
bstnA(gbl‐auto‐diag)# ...
CLI Maintenance Guide
8 - 39
Chapter 8
Troubleshooting Tools
Removing an Additional E-mail Recipient
Use no mail-to to remove one E-mail recipient from the auto-diagnostics
list:
no mail‐to recipient
where recipient (1-768 characters) is the E-mail address to remove.
You cannot remove "e-support@f5.com," the address for F5 Support.
For example, the following command sequence removes one of the E-mail
recipients that was added in the previous example:
bstnA(gbl)# auto‐diagnostics
bstnA(gbl‐auto‐diag)# no mail‐to jsmith@wwmed.com
bstnA(gbl‐auto‐diag)# ...
Displaying the Auto-Diagnostics Configuration
You can display the current auto-diagnostics configuration by executing the
show auto-diagnostics command. An example of the output from this
command follows:
bstnA# show auto‐diagnostics
Schedule: daily4am
Description: two hours between 4 and 6 AM
Start Time: Sun Sep 4 04:00:00 2005
Stop Time: Wed Jan 7 04:00:00 2015 (Expires in 1665 d 22:58:06)
Interval: 1 days
Duration: 02:00:00
Status: Paused (runs in 21:58:06)
Previous:
Run Time: Wed Jun 16 04:00:00 2010
End Time: Wed Jun 16 06:00:00 2010
Next:
Run Time: Thu Jun 17 04:00:00 2010
End Time: Thu Jun 17 06:00:00 2010
Mail‐to: juser@wwmed.com, mmorrison@wwmed.com
Additional commands:
show global service
show share status
Status:
Last time executed: 16 Jun 2010 09:19:53 AM UTC
8 - 40
Setting Up Remote Monitoring By F5 Support
Status of last execution: Success [ collect_diag_201006160919.rpt DONE ]
Date last sent: 16 Jun 2010 09:55:27 AM UTC
Number of times sent since last reboot: 2
Performing a Local Test of the Auto-Diagnostics Configuration
After you’ve configured auto-diagnostics behavior for your ARX, you can
execute a local test to verify that it works the way that you expect it will.
Type the privileged-exec mode CLI command auto-diagnostics test local
to send an unencrypted auto-diagnostics mail test message to the Email
addresses configured with the gbl-auto-diag mode mail-to command. No
mail is sent to F5 Networks when this command is executed.
CLI Maintenance Guide
8 - 41
Chapter 8
Troubleshooting Tools
Running Show Commands from a Remote Host
You can use SSH (the Secure SHell command) from a remote machine to
run any show command at an ARX. Earlier chapter describe how to run
various snapshot commands and/or a volume restore through SSH; recall
Running Snapshot Operations from a Remote Host, on page 2-34 and
Running the Restore from a Remote Host, on page 4-10. You use the same
ssh syntax to run show commands:
ssh admin‐user@mip “show‐command”
where
admin-user is the username for a valid administrative account at
the ARX (use show users to list all of them, as shown in Listing All
Administrative Users, on page 2-14 of the ARX® CLI
Network-Management Guide),
mip is a management-IP address for the ARX (use show interface
mgmt to show the out-of-band management interface, or show
interface vlan to show all in-band management interfaces), and
show-command is a show command to run remotely. Surround this
with quotation marks (““) if it contains any spaces.
The output of the show command appears in the local shell. For example,
this command sequence runs from a Unix machine named “mgmt17.” The
command runs show processors on “bstnA,” a remote ARX:
juser@mgmt17:~$ ssh admin@10.1.1.7 “show processors”
Command>show processors
Proc Module State Up Time Total Kb Free Kb CPU1M CPU5M
‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐
1.1 ACM Up 0 days, 01:50:00 16415268 15558320 3 2
2.1 NSM Up 0 days, 01:45:20 2714622 2105952 0 0
2.2 NSM Up 0 days, 01:45:20 2714622 2105952 0 0
2.3 NSM Up 0 days, 01:45:20 2714622 2105952 0 0
2.4 NSM Up 0 days, 01:45:20 2714622 2105952 1 1
2.5 NSM Up 0 days, 01:45:15 2714622 2148961 0 0
2.6 NSM Up 0 days, 01:45:15 2714622 2148961 0 0
2.7 NSM Up 0 days, 01:45:15 2714622 2148961 0 0
2.8 NSM Up 0 days, 01:45:15 2714622 2148961 1 1
2.9 NSM Up 0 days, 01:45:15 2714622 2105953 0 0
2.10 NSM Up 0 days, 01:45:15 2714622 2105953 0 0
2.11 NSM Up 0 days, 01:45:15 2714622 2105953 0 0
2.12 NSM Up 0 days, 01:45:15 2714622 2105953 1 1
juser@mgmt17:~$
Using Quotes within the Show Command
Some show commands require quotes within the command itself. This
confuses the CLI parser, and single quotes (‘) are also problematic. To work
around this issue, use the URL encoding for the double quote, %22, for the
inner quotes.
8 - 42
Running Show Commands from a Remote Host
For example, the following command shows a namespace named “test ns.”
The show namespace command requires quotes around “test ns” because it
has a space in it.
juser@mgmt17:~$ ssh admin@10.1.1.7 “show namespace %22test ns%22”
...
CLI Maintenance Guide
8 - 43
Chapter 8
Troubleshooting Tools
Notification Rules
The ARX provides support via its API for external applications such as F5
Data Manager and for third-party applications to obtain file system change
notification and configuration management services. Support for those API
services includes the ability to define notification rules on the ARX which
govern the creation of notification snapshots. Notification snapshots
summarize the changes made to the virtual filesystem by the external
applications that access it.
Notification rules are defined at the volume level, and provide information
about API-based actions that are taken. When a notification rule is defined,
it implicitly enables browsing of the snapshot directory in the volume. All
volume-level snapshot options apply to snapshots from notification rules.
Notification rules support the use of privileged exec mode snapshot
commands.
Note
The snapshot remove command must remove the oldest snapshot before it
removes any other snapshots. Without this restriction, file changes may be
lost when a snapshot in the middle is removed. If a snapshot is removed
while it is being used, the client will be notified, and it should rescan the
files.
Executing the gbl-ns-vol mode CLI command notification rule creates a
notification rule object and enters gbl-ns-vol-ntfy mode for defining the
rule. This mode provides the following CLI commands:
• enable, which activates the current snapshot rule.
• report prefix, where prefix is the prefix to be prepended to each report
name.
• retain number, where number is the number of reports to be held, up to
1024.
• schedule name, where name is the task schedule by which notification
snapshots will be generated.
The command syntax is:
notification rule name
where name is the notification rule to be defined or edited.
For example, the following command sequence creates a notification rule
named "accessReports", defines it, and enables it:
bstnA(gbl-ns-vol[wwmed~/acct])# notification rule accessReports
bstnA(gbl-ns-vol-ntfy[wwmed~/acct~accessReports])# report ar_
bstnA(gbl-ns-vol-ntfy[wwmed~/acct~accessReports])# schedule
hourly
bstnA(gbl-ns-vol-ntfy[wwmed~/acct~accessReports])# retain 10
bstnA(gbl-ns-vol-ntfy[wwmed~/acct~accessReports])# enable
8 - 44
Statistics Monitoring
Statistics Monitoring
The ARX software provides robust statistics monitoring functionality that
accumulates and, optionally, analyzes performance data for services and
shares, notifying you if the evidence suggests a possible problem with their
performance. This is done by comparing each sample of performance data
against a moving historical average of previous data collected for the same
sampled object, and generating a notification if that sample deviates from
the moving average by a configured percentage over a configured number of
sample intervals. By default, performance data is sampled every five
minutes.
Notification of performance-related events occurs through log messages
and/or SNMP traps. Each event type that is detected generates a separate
event; however, multiple instances of the same event type are not reported
more than once.
The data collected by the statistics monitor resides on each switch at
/acopia/var/log/stats-logs as comma-separated value (CSV) files that can be
opened in spreadsheet applications such as Microsoft Excel. These files can
be copied off the switch as desired for further examination and for
consultation with F5 support staff as necessary. One way of doing this is to
use the collect stats-logs CLI command to gather the statistics monitoring
files and write them to a location from which they can be shared easily.
Statistics monitoring data will not be written if the logs partition is 50% full
or more.
Note
The various clear statistics CLI commands will reset these statistics and will
be indicated by a reset marker in the log file. Clearing the global
configuration will clear the statistics monitor data; if you wish to retain this
data, make certain to copy it off the switch prior to clearing the global
configuration.
Note
In a redundant ARX pair, the statistics monitor is active only on the active
switch.
Execute the show stats-monitor CLI command to display the current
statistics monitor configuration:
bstnA# show stats‐monitor
Statistics Monitor Configuration
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Status Enabled
Sampling Interval 60 seconds
Max Data Size 500 MB
Max Raw Data Size 80% of Max
Used Data Size 7.4 MB
CLI Maintenance Guide
8 - 45
Chapter 8
Troubleshooting Tools
Used Raw Data Size 7.3 MB
Notification Parameters
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Applies To Statistics Traps Metric Parameters
‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
CIFS Shares Errors Disabled Mov.Avg >100% for 6 Samples
CIFS Shares RespTime Enabled Mov.Avg >25% for 2 Samples
Statistics monitoring is always enabled on the active switch.
The data size specifies the maximum amount of historical data that the
statistics monitor is allowed to retain, and is not configurable. Similarly, the
raw data size percentage, which controls the portion of the statistics log
capacity that can be used by the raw data files, is not configurable, either.
Statistics Monitor Command Mode
Note
All commands related to configuring the statistics monitor or accessing the
log files that it generates are in terminal beta mode. You must execute the
terminal beta CLI command in order for any of these commands to be
available.
After you’ve activated terminal beta mode, type stats-monitor in global
configuration mode to enter gbl-stmon mode. Use this mode to access the
statistics monitor log files, and to configure the statistics monitor’s sampling
and notification behaviors.
Changing the Data Sampling Interval
By default, performance data is sampled every 300 seconds.
To change the data sampling interval, use the sampling interval CLI
command in gbl-stmon mode to specify the number of seconds between
sampling intervals. This can range from a minimum of 30 to a maximum of
86,400 (one day).
For example:
bstnA(gbl‐stmon)# sampling interval 120
This configures an interval of two minutes between data samples.
Changing the Event Notification Parameters
Use the notify command in gbl-stmon mode to enter gbl-stmon-nfy mode for
configuring event notification for a CIFS service, NFS service, or filer
share. This controls when notification is sent because recent data is
anomalous in the context of similar performance statistics used to calculate
the moving average for the relevant parameter.
8 - 46
Statistics Monitoring
The syntax is:
notify {cifs‐service | filer‐share | nfs‐service}
This causes you to enter a submode corresponding to the type of service that
you specified, such as gbl-stmon-nfy[~cifs-service] if you executed notify
cifs-service. If you specify filer-share, you must also specify cifs or nfs.
Within each submode, you can use the commands metric, moving-average,
and trap to configure the corresponding event notification parameters for
that service type.
Metric Configuration
In the current release, moving-average is the sole metric against which error
counts and response times are compared to determine if they are within
expected norms or are anomolous. This is not configurable, currently.
The command syntax that describes the current configuration is:
metric errors moving‐average
metric response‐time moving‐average
Changing the Moving Average Configuration
You can configure how anomalies in error counts and response-times are
compared to the moving average for the purpose of event notification. For
each, there are two components to triggering a notification. The first is to
specify the number of sample intervals over which the presence of an
anomalous statistic will trigger an event notification; this changes the
moving average window. The second is to specify the threshold percentage,
which, when the statistic exceeds the moving average by that amount for the
specified number of intervals, an event notification is triggered. No
notification will occur until a full moving average window of data exists in
the statistics monitor raw files for that event.
The syntax for these commands follows:
moving‐average errors interval <1‐65535>
moving‐average errors threshold <percentage value>
moving‐average response‐time interval <1‐65535>
moving‐average response‐time threshold <percentage value>
Changing the Trap Configuration
SNMP trap generation is disabled by default. You can specify whether an
error count event or a response-time event sends an SNMP trap by using
these commands:
trap errors
trap response‐time
Configuring Email Notification
The Email group, stats-monitor, can be configured for trap notification for
the following events:
• filer-slow-clear: Filer share slowness is cleared.
CLI Maintenance Guide
8 - 47
Chapter 8
Troubleshooting Tools
• filer-slow-raise: A filer share is slow.
• service-slow-clear: Service slowness is cleared.
• service-slow-raise: A service is slow.
• filer-errors-clear: Filer errors are normal.
• filer-errors-raise: Filer errors exceed the notificiation thresholds.
• service-errors-clear: Service errors are normal.
• service-errors-raise: Service errors exceed the notification thresholds.
For each event, the notification threshold is configured according to the
number of occurrences within a specified time interval, as is done for events
for other Email groups. Refer to the ARX® CLI Reference for complete
details of the group stats-monitor command.
Statistics Monitor Log Files
List the statistics monitor log files that are present on the switch by
executing the show stats-logs CLI command.
For example:
bstnA(gbl‐stmon)# show stats‐logs
stats‐logs
cifs‐service_20110621_170225.raw.stats.csv 06/22 13:03 934 kB
cifs‐service_20110621_190000.hourly.stats.csv 06/23 17:00 36 kB
cifs‐service_20110622_170321.raw.stats.csv 06/23 13:04 955 kB
cifs‐service_20110623_170421.raw.stats.csv 06/23 17:58 197 kB
cifs‐service‐auth_20110621_170225.raw.stats.csv 06/22 13:03 478 kB
cifs‐service‐auth_20110621_190000.hourly.stats.csv 06/23 17:00 18 kB
cifs‐service‐auth_20110622_170321.raw.stats.csv 06/23 13:04 489 kB
cifs‐service‐auth_20110623_170421.raw.stats.csv 06/23 17:58 101 kB
cifs‐share_20110621_170225.raw.stats.csv 06/21 21:43 10 MB
...
The following stats-log file types are supported:
• cifs-service: This file type contains data plane CIFS service statistics,
with services identified by their FQDN.
• cifs-service-auth: This file type contains CIFS service authentication
statistics. The services are identified by their FQDN.
• cifs-share: This file type contains data plane and control plane CIFS filer
share statistics, with shares identified by their namespace, volume, and
share name in the ARX configuration.
• cifs-work-queue: This file type contains CIFS work queue statistics.
Work queues are identified by their volume group ID.
• domain-controller: This file type contains domain controller statistics.
Domain controllers are identified by their IP address.
8 - 48
Statistics Monitoring
• metadata: This file type contains metadata statistics; objects in this file
are identified by their namespace and volume.
• metalog: This file type contains metalog statistics; objects in this file are
identified by their volume group ID.
• migration: This file type contains migration statistics. Objects in this file
are identified by their namespace and volume.
• nfs-service: This file type contains data plane NFS service statistics, with
services identified by their FQDN.
• nfs-share: This file type contains data plane and control plane NFS filer
share statistics, with shares identified by their namespace, volume, and
share name in ARX configuration.
File Naming Convention
Each statistics log file name indicates the type of object for the data
contained in the file, and includes a file creation timestamp and the string
"raw" or "hourly" to indicate whether the file contains an original data
sample or an hourly aggregate of performance data.
For example:
cifs‐service_20110621_170225.raw.stats.csv
Log File Contents
You can view a particular log file by executing the show stats-logs filename
command. For example:
bstnA(gbl‐stmon)# show stats‐logs cifs‐service_20110621_190000.hourly.stats.csv
BEGIN cifs‐service version=1 timestamp=1308682800
TIMESTAMP,KEY,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,CO
UNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTE
R,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TO
TALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALT
IME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,
COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUN
TER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,
TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTA
LTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,TOTALTIME,COUNTER,COUNTER,
COUNTER,COUNTER,COUNTER,COUNTER,COUNTER
Timestamp,fqdn,CheckDir‐RTT,CheckDir‐RTC,Close‐RTT,Close‐RTC,Create‐RTT,Create‐RTC,CreateDir‐RTT,C
reateDir‐RTC,Delete‐RTT,Delete‐RTC,DeleteDir‐RTT,DeleteDir‐RTC,Echo‐RTT,Echo‐RTC,FindClose2‐RT
T,FindClose2‐RTC,Flush‐RTT,Flush‐RTC,LockingAndX‐RTT,LockingAndX‐RTC,LogoffAndX‐RTT,LogoffAndX
‐RTC,Negotiate‐RTT,Negotiate‐RTC,NTCancel‐RTT,NTCancel‐RTC,NTCreateAndX‐RTT,NTCreateAndX‐RTC,N
TRename‐RTT,NTRename‐RTC,NTTransact/Create‐RTT,NTTransact/Create‐RTC,NTTransact/GetUserQuota‐R
TT,NTTransact/GetUserQuota‐RTC,NTTransact/Ioctl‐RTT,NTTransact/Ioctl‐RTC,NTTransact/NotifyChan
ge‐RTT,NTTransact/NotifyChange‐RTC,NTTransact/QuerySecurity‐RTT,NTTransact/QuerySecurity‐RTC,N
TTransact/SetSecurity‐RTT,NTTransact/SetSecurity‐RTC,Open‐RTT,Open‐RTC,OpenAndX‐RTT,OpenAndX‐R
TC,QueryInfo‐RTT,QueryInfo‐RTC,QueryInfoDisk‐RTT,QueryInfoDisk‐RTC,Read‐RTT,Read‐RTC,ReadAndX‐
RTT,ReadAndX‐RTC,Rename‐RTT,Rename‐RTC,Seek‐RTT,Seek‐RTC,SessionSetupAndX‐RTT,SessionSetupAndX
‐RTC,SetInfo‐RTT,SetInfo‐RTC,Transaction‐RTT,Transaction‐RTC,Transaction2/CreateDir‐RTT,Transa
ction2/CreateDir‐RTC,Transaction2/FindFirst2‐RTT,Transaction2/FindFirst2‐RTC,Transaction2/Find
Next2‐RTT,Transaction2/FindNext2‐RTC,Transaction2/GetDFSReferral‐RTT,Transaction2/GetDFSReferr
al‐RTC,Transaction2/QueryFSInfo‐RTT,Transaction2/QueryFSInfo‐RTC,Transaction2/QueryFileInfo‐RT
T,Transaction2/QueryFileInfo‐RTC,Transaction2/QueryPathInfo‐RTT,Transaction2/QueryPathInfo‐RTC
CLI Maintenance Guide
8 - 49
Chapter 8
Troubleshooting Tools
,Transaction2/SetFileInfo‐RTT,Transaction2/SetFileInfo‐RTC,Transaction2/SetPathInfo‐RTT,Transa
ction2/SetPathInfo‐RTC,TreeConnectAndX‐RTT,TreeConnectAndX‐RTC,TreeDisconnect‐RTT,TreeDisconne
ct‐RTC,Write‐RTT,Write‐RTC,WriteAndX‐RTT,WriteAndX‐RTC,UnknownSMB‐RTT,UnknownSMB‐RTC,FormatErr
or,NetworkError,ResourceError,SignatureError,SMBError,TimeoutError
1308682800,mpns.acopianet.com,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
1308682800,ntlmonly.acopianet.com,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
1308682800,XERXES.ny.com,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
,0,0,0,0,0,0,0,0,0,0,0,0,0,0
...
Within the file, the prefixes of the field names correspond to the name of the
relevant CIFS or NFS protocol message; RTT stands for the accumulated
round trip time, and RTC stands for the count of operations over which the
RTT was accumulated. These response times are expressed in
microseconds. For each error counter, there is a single column giving the
error count.
For easier reading and better usability, copy the file off of the switch and
view its contents using a spreadsheet application, or any other application
capable of displaying a CSV file in an acceptable fashion.
New raw files are created when the existing file reaches 10 MB in size or the
file contains 24 hours of data.
New hourly files are created when the existing file reaches 5 MB in size or
the file contains seven days of data.
8 - 50
9
Troubleshooting Network Connections
• Pinging an IP Address
• Using Traceroute
• Testing Throughput with TTCP
• Tracing NSM Processes in the “fastpath” Log
• Capturing IP Traffic in a File
• Configuring Port Mirroring
• Showing Filer-Connection Statistics
Pinging an IP Address
Pinging an IP Address
From any mode, use the ping command to send an ICMP ECHO request to
another interface:
ping ip‐address
where ip-address (for example, 10.10.10.1) is the destination for the
ping.
The ARX pings the IP address repeatedly until you stop it by pressing
<Ctrl-C>. Once you stop it, a report summarizes the results of the ping test.
For example:
bstnA# ping 172.16.100.183
PING 172.16.100.183 (172.16.100.183) 0 data bytes
8 bytes from 172.16.100.183: icmp_seq=1 ttl=62 time=3 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=2 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=3 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=4 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=5 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=6 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=7 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=8 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=9 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=10 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=11 ttl=62 time=<1 ms. from 2.3
‐‐‐‐‐‐‐172.16.100.183 ping statistics
11 packets transmitted, 11 packets received, 0% packet loss
round‐trip min/avg/max 0/0/3 ms
bstnA# ...
Limiting the Ping Count
To limit the number of pings up front, use the count clause with the ping
command:
ping ip‐address count number
where
ip-address is the destination for the ping, and
number (1-10,000) is the number of pings to send.
For example:
bstnA# ping 172.16.100.183 count 4
PING 172.16.100.183 (172.16.100.183) 0 data bytes
8 bytes from 172.16.100.183: icmp_seq=1 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=2 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=3 ttl=62 time=<1 ms. from 2.3
8 bytes from 172.16.100.183: icmp_seq=4 ttl=62 time=<1 ms. from 2.3
‐‐‐‐‐‐‐172.16.100.183 ping statistics
4 packets transmitted, 4 packets received, 0% packet loss
round‐trip min/avg/max 0/0/0 ms
bstnA# ...
CLI Maintenance Guide
9-3
Chapter 9
Troubleshooting Network Connections
Pinging From an Alternate Source IP
You can use an alternate source-IP address in a ping. By default, the source
IP is calculated based on the originating processor’s routing table.
There are three types of internal IP addresses that you can use as sources for
ping: proxy IPs, Virtual IPs, and management IPs.
• The network processors use proxy-IP addresses to communicate with
servers. Use the show ip proxy-addresses command (see Showing all
Proxy IPs, on page 4-8 of the ARX® CLI Network-Management Guide)
to list all proxy-IP addresses. Each network processor is assigned its own
proxy-IP.
• The network processors use virtual-IP (VIP) addresses to communicate
with clients. Use the show global server command (see Showing All
Global Servers, on page 10-12 of the ARX® CLI Storage-Management
Guide) to list all VIPs.
• There are two types of management interface: one in-band interface for
each VLAN and one out-of-band (OOB) management interface. Use the
show interface vlan command to list all VLAN-management interfaces
(see Listing all VLAN Management Interfaces, on page 4-6 of the ARX®
CLI Network-Management Guide). Use show interface mgmt to find the
source address for the OOB Mgmt interface (see Showing the Interface
Configuration and Status, on page 4-21 of the ARX® CLI
Network-Management Guide).
If you set a source IP without setting the source processor, the source IP
determines the processor. For example, if you choose the IP for the
out-of-band management port, the CLI sends the ping from the SCM
processor.
Use the source clause with the ping command to send an alternate source IP
in the ICMP ECHO request:
ping ip‐address [from slot.processor] source source‐address [count number]
where
ip-address is the destination for the ping,
from slot.processor (optional, 1-2.1-12) chooses a source
processor. If you choose the processor and the source-address,
they may conflict: the ping may not return to the processor that sent
it. If you omit this, the CLI chooses the correct processor. In
general, this should be omitted.
source-address is the source-IP address to send in the ICMP
ECHO.
count number (optional, 1-10,000) limits the number of pings, as
explained above.
For example, this command sends a ping with a source IP of 10.50.20.110:
bstnA> ping 10.53.2.10 source 10.50.20.110 count 2
PING 10.53.2.10 (10.50.20.110) 0 data bytes
8 bytes from 10.53.2.10: icmp_seq=1 ttl=0 time=100 ms. src addr 10.50.20.110
9-4
Pinging an IP Address
8 bytes from 10.53.2.10: icmp_seq=2 ttl=0 time=100 ms. src addr 10.50.20.110
‐‐‐‐‐‐‐10.53.2.10 ping statistics
2 packets transmitted, 2 packets received, 0% packet loss
round‐trip min/avg/max 1/1/2 ms
bstnA> ...
Pinging the OOB Management Network
As implied above, you can ping the out-of-band (OOB) management
network by using the OOB Mgmt address as the source IP. This ping starts
at the SCM processor and goes through the management gateway. For
example, the following command sequence finds the OOB management IP
and gateway and then pings the management gateway. These pings go over
the management network, not the client/server network:
prtlndA> show interface mgmt
Slot 1
Interface 1
Description
Admin Status Enabled
Link Status Up
Speed 1 Gb/s
Duplex Full
Auto Negotiation Disabled
MAC Address 00:15:17:6b:a9:71
MTU Size 1500
IP Address 10.1.23.11
Subnet Mask 255.255.0.0
prtlndA> show ip route
Destination/Mask Gateway Cost Interface Age
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
0.0.0.0/0 192.168.74.1 128 VLAN74 9199
0.0.0.0/0 10.1.23.1 128 Mgmt 9430
192.168.74.0/24 0.0.0.0 0 VLAN74 Direct
192.168.74.0/24 0.0.0.0 128 VLAN Direct
192.168.74.0/24 0.0.0.0 0 VLAN74 Direct
192.168.74.0/24 0.0.0.0 128 VLAN Direct
192.168.78.0/24 0.0.0.0 128 VLAN Direct
192.168.78.0/24 192.168.74.2 128 VLAN74 9214
10.1.23.0/24 0.0.0.0 0 Mgmt Direct
prtlndA> ping 10.1.23.1 source 10.1.23.11 count 4
PING 10.1.23.1 (10.1.23.11) 0 data bytes
8 bytes from 10.1.23.1: icmp_seq=1 ttl=255 time=<1 ms. src addr 10.1.23.11
8 bytes from 10.1.23.1: icmp_seq=2 ttl=255 time=<1 ms. src addr 10.1.23.11
8 bytes from 10.1.23.1: icmp_seq=3 ttl=255 time=<1 ms. src addr 10.1.23.11
8 bytes from 10.1.23.1: icmp_seq=4 ttl=255 time=1 ms. src addr 10.1.23.11
‐‐‐‐‐‐‐10.1.23.1 ping statistics
4 packets transmitted, 4 packets received, 0% packet loss
round‐trip min/avg/max 1/0/1 ms
prtlndA> ...
CLI Maintenance Guide
9-5
Chapter 9
Troubleshooting Network Connections
Using Traceroute
You can use the expect traceroute command to show each IP-router hop
between the NSM and a given IP address. Like ping, the expect traceroute
command is accessible from any mode:
expect traceroute destination‐address [timeout seconds]
where
destination-address is the IP-address for the traceroute, and
timeout seconds (optional, 1-2096) limits the time for the
traceroute process.
If a hop is unreachable, the command outputs asterisks (*) until you
interrupt it or it times out. Use <Ctrl-C> to interrupt the expect traceroute
command.
The packet starts at an inband (VLAN) management interface.
Inband-management interfaces were discussed in Configuring an In-Band
(VLAN) Management Interface, on page 4-4 of the ARX® CLI
Network-Management Guide.
This sample command traces the route to the filer at 192.168.25.19:
bstnA# expect traceroute 192.168.25.19
1 192.168.25.1 0.587 ms 0.553 ms 0.491 ms
2 192.168.25.19 0.367 ms 0.363 ms 0.367 ms
bstnA# ...
9-6
Testing Throughput with TTCP
Testing Throughput with TTCP
The Test TCP (TTCP) utility is a benchmarking tool to measure throughput
over TCP or UDP connections. You can run a TTCP test from the SCM
processor to any filer, client station, or other server that supports TTCP.
(TTCP tools are freely available from the Internet.) After configuring a
remote station to receive TTCP transmissions, use the expect ttcp transmit
command to invoke a 10-second test:
expect ttcp transmit ttcp‐server‐address [timeout seconds]
where
ttcp-server-address is the IP-address for the pre-configured server,
and
timeout seconds (optional, 1-2096) sets a time limit for the TTCP
test.
When the test ends, the CLI shows the results in a one-line report. For
example, the following command runs a test to the station at 192.168.98.55:
bstnA# expect ttcp transmit 192.168.98.55 Starting 10 second TCP transmit test. Hit ^C to abort...
1003.0552 MB / 10.00 sec = 841.3741 Mbps 9 %TX
bstnA#
The %TX field at the end of the output is the percent-CPU used by the SCM
processor.
Cancelling a TTCP Transmission
For cases where a connection error is causing the transmit to hang (for
example, if TTCP is not configured at the server), use <Ctrl-C> to cancel the
test. For example,
bstnA# expect ttcp transmit 192.168.97.55
Starting 10 second TCP transmit test. Hit ^C to abort...<Ctrl‐C>
bstnA#
The optional timeout argument also cancels the test.
Testing a RON Tunnel
To test the RON connection from one ARX to another, run expect ttcp
server at the receiving switch and then expect ttcp transmit from the sending
switch. (For information on creating a RON tunnel, refer back to Creating a
Tunnel to Another ARX, on page 6-4 of the ARX® CLI
Network-Management Guide.) Like the previous expect commands, you run
expect ttcp server from any mode:
expect ttcp server [timeout seconds]
CLI Maintenance Guide
9-7
Chapter 9
Troubleshooting Network Connections
The CLI stops to wait for a TTCP transmission from another switch. The
CLI remains blocked until you press <Ctrl-C> to stop waiting. For example,
the following command waits for a TTCP transmission on the switch,
“prtlndA:”
prtlndA# expect ttcp server
Waiting for TTCP client. Hit ^C to abort...
Go to the sending switch to run the test. The IP address to use for the server
switch is the.1 address on the server’s private subnet. Use the show ron route
command (see Showing the RON Routes, on page 6-10 of the ARX® CLI
Network-Management Guide) to find the private subnet for the server
switch. To continue the example, this command sequence finds the private
subnet for “prtlndA,” then runs a TTCP test over the RON tunnel:
bstnA# show ron route
Default Policy
‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Destination Subnet via Tunnel Milliseconds
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
canbyA 169.254.116.0/24 toCanby 0.1
newptA 169.254.151.64/26 toNewport 0.1
provA 169.254.195.128/26 toProvidence 0.1
prtlndA 169.254.140.0/24 toPortland 0.1
prtlndB 169.254.104.0/24 toPortlandB 0.1
stkbrgA 169.254.131.0/24 toStockbridge 0.3
stoweA 169.254.76.0/24 toStowe 0.1
bstnA# expect ttcp transmit 169.254.24.1
Starting 10 second TCP transmit test. Hit ^C to abort...
586.5138 MB / 10.00 sec = 491.9229 Mbps 12 %TX 23 %RX
bstnA#
When the test is over, go back to the server switch and press <Ctrl-C>:
Waiting for TTCP client. Hit ^C to abort... <Ctrl‐C>
prtlndA# The server switch can only receive TTCP transmissions from another ARX
on the same RON.
9-8
Tracing NSM Processes in the “fastpath” Log
Tracing NSM Processes in the “fastpath” Log
To debug a connectivity issue, you can trace the software processes on an
NSM processor. A traced NSM processor sends its log messages to a file
named “fastpath,” which is similar to the “syslog” file described in the
previous chapter. From cfg mode, use the logging fastpath processor
command to choose an NSM processor to trace:
logging fastpath processor slot.processor
where
slot (2 on an ARX-4000; 1 on an ARX-2500, ARX-2000,
ARX-1500, or ARX-500) is the slot number of the desired NSM,
and
processor (1-12) is the processor number. Use show processors for
a complete list of processors (and their modules and slots) on the
ARX.
Important
NSM processes can be very verbose on a busy ARX. This slows client/server
traffic at the chosen processor. Use this option only under the guidance of
F5 personnel.
The first time you issue any logging fastpath command, the CLI issues a
warning about the performance impact. Enter yes to continue. This prepares
the processor for minimal logging. You can increase the volume of logs for
individual processes and process groups on the NSM, as shown below.
For example, the following command configures NSM processor 2.1 for
logging:
bstnA(cfg)# logging fastpath processor 2.1
Enabling fastpath logging adversely impacts the performance of the switch.
Proceed? [yes/no] yes
bstnA(cfg)# ...
NSM-Log Components
Every NSM-log message originates from a log component on the NSM. A
log component is a source of fastpath-log messages, typically an internal
NSM process or group of processes. They are similar to the log components
CLI Maintenance Guide
9-9
Chapter 9
Troubleshooting Network Connections
that write to the syslog, described in Log Components, on page 8-9. The
table below is an alphabetical list of all NSM log components, along with a
brief description.
Log Component
Description
NSM_BSD
Board Support Package.
NSM_CACHE
NSM Cache.
NSM_CIFS
CIFS Proxy on the data plane.
NSM_CM
Connection Manager.
NSM_DGRAM
Datagram.
NSM_DME
Data Mover Engine (DME) proxy on the data plane. This migrates files
from one back-end filer to another.
NSM_DMS
NSM DMS.
NSM_DT
Direct Transport.
NSM_ECHO
Packet Echo Service.
NSM_GWMON
Gateway Monitor.
NSM_HA
High-Availability.
NSM_HOT
Hot files.
NSM_IPA
AIPC Server and Client, for internal communication between network
processes.
NSM_LIB
Networking Library Functions.
NSM_LOG
System Logging.
NSM_LOOP
Packet Loop Service.
NSM_MSG
Inter-NSM Messaging.
NSM_NAT
The Start of tem message categories.
NSM_NAT
NAT Subsystem.
NSM_NET_HEALTH
Network Health Checks.
NSM_NFS
NFS Proxy on the data plane.
NSM_NFS_CLIENT
NSM NFS client.
NSM_NFS_DNAS
The NFS proxy interactions with DNAS (becoming obsolete).
NSM_NFS_FC
NFS File Cache Management Proxy.
NSM_NFS_IPC
The NFS Proxy IPC (obsolete?).
NSM_NFS_MOUNT
Obsolete.
NSM_NFS_SERVER
NFS file server state machine.
NSM_NFS_STATE
The NFS proxy state machine (becoming obsolete).
NSM_NLM
NFS Lock Manager (NLM) proxy on the data plane.
NSM_PING
PING Application.
NSM_PORT
Port Management.
NSM_PRESTO
Presto Console Log.
9 - 10
Tracing NSM Processes in the “fastpath” Log
Log Component
Description
NSM_RON
RON Fastpath Proxy.
NSM_SNTP
SNTP.
NSM_STATS
Statistics from the data plane.
NSM_TEME
Fastpath environment-kernel.
NSM_TFTP
TFTP Client.
NSM_TTCP
TTCP Service.
NSM_VIP
VIP Processing.
NSM_VIP_FENCE
NSM_XID_MAP
VIP Fencing, which can occur when an ARX volume is creating a
coordinated snapshot. The VIP fence, while it is raised, prevents clients
from changing any volume state while its back-end filers are each taking
their snapshots.
NFS RPC XID Mapping.
Adjusting NSM Logging Levels
Each NSM-log component has a logging level that determines the volume of
logs that it generates. You can set a different logging level for every
NSM-log component, allowing you to focus attention on a single NSM
component or a small group of them.
From cfg mode, use the logging fastpath component command to change the
logging level for one NSM-log component:
logging fastpath component name level
where
name (1-128 characters) is an NSM-log component from the list of
NSM-Log Components, on page 9-9, and
level (0-10) chooses the logging level for the component. A 0
(zero) stops all messages from the component. A 1 causes the
component to log non-recoverable errors only; this is the default. A
2 or 3 adds warnings and recoverable errors. A 4 adds logs about
internal configuration changes. Levels 5 through 10 add increasing
densities of per-packet messages.
Important
The log output can get very verbose. A busy NSM processor may fail if this
level is set too high for too long. You should only use this feature under the
strict guidance of F5 personnel.
The first time you enter any logging fastpath command, the CLI warns you
about the performance impact. If the warning appears, enter yes to proceed.
CLI Maintenance Guide
9 - 11
Chapter 9
Troubleshooting Network Connections
This logging level applies to all NSMs that have been enabled for logging
with logging fastpath processor, described earlier.
For example, the following command sets the logging level to 6 (a low
volume of per-packet logs) for the NSM_CIFS component:
bstnA(cfg)# logging fastpath component NSM_CIFS 6
bstnA(cfg)# ...
Filtering the Log Messages
You can focus the log output by filtering for a particular subnet, IP address,
or other search string. Add a filter clause to the end of the logging fastpath
component command:
logging fastpath component name filter match‐string {include | exclude}
where
name (1-128 characters) is an NSM-log component from the list of
NSM-Log Components, on page 9-9.
match-string (1-80 characters) is a string to match against. Quote
the string if it contains any spaces.
include | exclude is a required choice: include collects any log
message that matches the match-string, while exclude omits all
matching log messages and gathers all other messages.
You can repeat this command multiple times to expand or narrow the search
further. A packet that matches any of the entered filters is included in the log
file (or excluded from it, if you use the exclude keyword). Log messages are
matched in the order that you enter them, so a command to include logs with
“10.10.53.99” is ineffective if a previous filter excludes “10.10.”
As above, the CLI may prompt with a performance warning before it sets
the filter. If necessary, enter yes to continue.
For example, this command sequence filters all NSM_CIFS logs down to
packets containing either 192.168.25.15, 172.16.100.183, or both:
bstnA(cfg)# logging fastpath component NSM_CIFS filter 192.168.25.15
bstnA(cfg)# logging fastpath component NSM_CIFS filter 172.16.100.183
bstnA(cfg)# ...
Disabling Log Messages for an NSM Component
You can stop all log messages from a given NSM component; this applies to
every instance of the component, on every NSM processor that is enabled
for logging. Use the no form of the logging fastpath component command:
no logging fastpath component name
where name identifies the NSM-log component to disable (see
NSM-Log Components, on page 9-9), and
This is equivalent to logging fastpath component name 0.
For example, the following command disables logging from the NSM_CIFS
component:
9 - 12
Tracing NSM Processes in the “fastpath” Log
bstnA(cfg)# no logging fastpath component NSM_CIFS
bstnA(cfg)# ...
Showing All NSM-Log Components and Levels
Use the show fastpath logging command to see the logging levels for all
NSM-log components:
show fastpath logging
This displays two tables. The first lists all of the NSM processors with
logging enabled. The second lists all of the components that are being
traced, along with any filtering configuration.
For example:
bstnA(cfg)# show fastpath logging
Slot Processor
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1 1
1 2
3
Component Trace Level Filter Type Filter String
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
NSM_CIFS 6
NSM_CIFS inclusive 192.168.25.15
NSM_CIFS inclusive 172.16.100.183
...
Disabling Logs from an NSM Processor
Remember to stop all NSM processors from logging as soon as you finish
your tracing session; NSM logging degrades performance. Use no logging
fastpath processor to disable logging from a certain processor:
no logging fastpath processor slot.processor
where
slot (2 on an ARX-4000; 1 on an ARX-2500, ARX-2000,
ARX-1500, or ARX-500) is the slot number of the desired NSM,
and
processor (1-12) is the processor number. Use show processors for
a complete list of processors (and their modules and slots) on the
ARX.
For example, the following command sequence stops three NSM processors
from logging:
bstnA(cfg)# no logging fastpath processor 2.1
bstnA(cfg)# no logging fastpath processor 2.2
bstnA(cfg)# no logging fastpath processor 2.3
bstnA(cfg)# ...
CLI Maintenance Guide
9 - 13
Chapter 9
Troubleshooting Network Connections
Accessing the fastpath Log
You can use show logs fastpath to view the fastpath file and tail logs fastpath
follow to follow it as it grows. To search through the fastpath file for a
pattern, use grep pattern logs fastpath. These are the same commands used
to access the syslog file, as described in.Accessing the Syslog, on page 8-7.
For example, the following command shows the fastpath log file:
bstnA(cfg)# show logs fastpath
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_conn_hdlr.c:117: New cifs connection cid:19, type:7 remote‐addr:172.16.100.183
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_nbss.c:50: nbss‐sess‐req: session‐request rxed from client:172.16.100.183
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_nbss.c:279: netbios session request 72 from client:172.16.100.183
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_nbss.c:288: cifss nbss name :41433120202020202020202020202020
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_nbss.c:289: cifss nbss name in the session request:31302E35352E31302E31303620202020
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_nbss.c:304: netbios session established
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_neg.c:320: neg‐prot request from cid:19, client:172.16.100.183 ‐ send to dnas
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_neg.c:245: send neg‐prot reply back to cid:19 client:172.16.100.183
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_sess.c:891: session‐setup request from cid:19, mid:1, client:172.16.100.183 ‐ send to dnas
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_sess.c:469: rxed dnas sess resp:cid:19, mid:1, user/domain:MEDARCH\LAB
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_sess.c:647: send session‐setup reply to client:172.16.100.183 cid:19 uid:1
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_tree.c:838: rxed tree connect andx req from client:172.16.100.183, cid:19, uid:1
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_tree.c:345: rxed new session resp from dnas for cid:19, mid:1
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_tree.c:224: send tc to dnas:33, TID:1
2006‐11‐22T08:43:29.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: smb_tree.c:1816: rxed tree connect resp from dnas:send reply client:172.16.100.183,cid:19,mid:1,tid:1
2006‐11‐22T08:43:30.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_proxy.c:415: cifss‐conn:CIFS connection DOWN event. Client:192.168.25.15:53711 VIP:192.168.25.15:139
2006‐11‐22T08:43:30.000+0000:bstnA:5‐5‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_conn_hdlr.c:733: CIFS client conn teardown cid :19 client:172.16.100.183
...
NSM-Log-Message Syntax
Each line in the fastpath log file uses the following syntax:
utc.uuu+tz:switch:slot‐proc‐board‐pid:cmp‐ins‐sev‐id:: msg
This is the same format as is used in the syslog file (recall Syslog Syntax, on
page 8-16). For example,
2006‐11‐22T08:43:30.000+0000:bstnA:3‐2‐NSM_TX‐2124:NET_APP‐0‐7‐MSG7:: cifs_proxy.c:415: cifss‐conn:CIFS connection DOWN event. Client:192.168.25.15:53711 VIP:192.168.25.15:139
Where
• utc (2006-11-22T08:43:30 in the example) is the time in UTC.
• uuu (000) is the millisecond time fraction.
9 - 14
Tracing NSM Processes in the “fastpath” Log
• +tz (+0000) is the hours off UTC (+nnnn or -nnnn).
• switch (bstnA) is the switch name.
• slot-proc-board (3-2-NSM_TX) is the chassis slot, processor number, and
board type (always NSM). Use the show processors command for a list
of all processors and their associated modules.
• pid (2124) is the Process ID (PID).
• cmp (NET_APP) is the log-component name. Refer to NSM-Log
Components, on page 9-9.
• ins (0) is the process’s instance number.
• sev (7) is the message severity, from 7 (debug) to 2 (critical).
• id (MSG7) is the message-catalog ID, a unique ID for each log message.
MSGn is an ID for an uncatologued message. The n is the severity of the
message, from 7 (debug) down to 2 (critical).
• msg (cifs_proxy.c:415: cifss-conn: CIFS ...) is the message
text itself.
CLI Maintenance Guide
9 - 15
Chapter 9
Troubleshooting Network Connections
Capturing IP Traffic in a File
From priv-exec mode, you can use the capture session command to start
capturing IP traffic and stream it into a file:
capture session session‐id ip ip‐address [and‐ip ip2] vlan vlan‐id file prefix
where
session-id (1-4; 1-2 on the ARX-500) identifies this capture
session, so that you can close it later.
ip-address is the address to match against. The capture includes all
packets whose source IP or destination IP matches this address.
and-ip ip2 (optional) is a second IP address. If you select this
option, the capture includes only the packets between ip-address
and ip2 in both directions.
vlan vlan-id (1-4095) specifies the VLAN.
prefix (1-255 characters) is the prefix you choose for the file name.
Each file is named as follows:
prefix.cap
Files are named with this format if there are more than one:
prefix_nnnnn_yyyymmddHHMMSS.cap
where prefix is what you choose here, nnnnn is a file number for
this session (there can be multiple files for each capture session, as
explained later), and yyyymmddHHMMSS is the date and time the
file was created.
A capture session begins when you invoke the command and ends when the
capture file reaches its maximum size, or when you stop it with no capture
session. The maximum file size and the no capture session command are
both described below.
The ARX prepares for the capture session by internally re-routing some of
its IP traffic. This may take several minutes, especially on a busy system.
After you enter the command, a message appears to warn you of the possible
delay.
Note
Jumbo frames are not included in a capture session.
For example, the following command sequence exits to priv-exec mode,
captures traffic between two IP addresses, and places it in a file with the
prefix, “clientCap.” This only captures packets on VLAN 25.
bstnA(cfg)# end
bstnA# capture session 1 ip 172.16.100.183 and‐ip 192.168.25.10 vlan 25 file clientCap
% INFO: Configuring network; this may take up to 6 minutes to complete.
bstnA# ...
9 - 16
Capturing IP Traffic in a File
Changing the Size and Number of Capture Files
By default, the capture session stops when it fills a single file with 16,000
kilobytes of data. You can use the filesize and/or filecount options to change
the size and number of capture files:
capture session session‐id ip ip‐address [and‐ip ip2] vlan vlan‐id file prefix [filesize kilobytes] [filecount count]
where
session-id, ip-address, ip2, vlan-id, and prefix are all described
above.
filesize kilobytes (optional, 1-50,000; 1-1,000,000 on an
ARX-4000) limits the size of the file; once the file reaches this
limit, the capture stops. (One kilobyte is 1,000 bytes, not 1,024.)
The default is 16,000 kilobytes.
filecount count (optional, 1-10) sets up a series of capture files;
when the capture reaches the filesize limit, it can close the current
capture file and start a new one. The default is 1 file. If you set a
count of 2 or more, the capture process rotates the capture files
indefinitely, and does not stop capturing packets until you use no
capture session.
For example, the following command sequence starts another capture
session that is limited to a single 500-Kbyte file:
bstnA(cfg)# end
bstnA# capture session 4 ip 192.168.25.19 vlan 25 file shadow_usage filesize 500
% INFO: Configuring network; this may take up to 6 minutes to complete.
bstnA# ...
Focusing on CIFS Traffic
You can filter out all packets in the capture except those related to CIFS.
Specifically, you can focus on traffic to or from the following ports on your
chosen IP address(es):
• UDP/88 or TCP/88
• UDP/137
• UDP/138
• TCP/139
• TCP/445
To focus only on traffic to or from the above ports, use the optional
protocol cifs arguments at the end of the command:
capture session session‐id ip ip‐address ... [protocol cifs]
where
all of the options except the final one are described above.
CLI Maintenance Guide
9 - 17
Chapter 9
Troubleshooting Network Connections
protocol cifs (optional) filters out all traffic except CIFS-related
traffic.
For example, the following command sequence starts another capture
session for CIFS-related traffic:
bstnA(cfg)# end
bstnA# capture session 2 ip 192.168.25.27 vlan 25 file fsrvr protocol cifs
% INFO: Configuring network; this may take up to 6 minutes to complete.
bstnA# ...
Filtering Out CIFS Traffic
You can use protocol non-cifs to filter out all CIFS-related traffic from the
capture file(s).
capture session session‐id ip ip‐address ... [protocol non‐cifs]
Specifically, this ignores all packets to or from the list of ports in the
previous section.
Stopping the Capture
From priv-exec mode, use no capture session to stop the capture
immediately or remove a capture session that has stopped:
no capture session session‐id [no‐merge]
where
session-id (1-4) identifies the capture session to close.
no-merge (optional) prevents the command from automatically
merging the output files. This is only relevant if the capture session
generated 2 or more files, as specified with the filecount option. If
you omit this, the merged filename is “prefix.cap” and contains all
captured packets in chronological order.
Any capture session persists until you use this command to stop it, whether
or not it has stopped writing to a file.
For example, this stops the session that we started in an earlier example:
bstnA# no capture session 1
% INFO: Configuring network; this may take up to 6 minutes to complete.
bstnA# ...
9 - 18
Capturing IP Traffic in a File
Capturing All Proxy-IP Traffic
You can monitor all traffic to and from the back-end filers with the proxy-all
option. This captures any packet whose source or destination IP address is
any of the proxy-IP addresses on the ARX (recall Adding a Range of
Proxy-IP Addresses, on page 4-7 of the ARX® CLI Network-Management
Guide). This option does not require a VLAN ID:
capture session session‐id proxy‐all file prefix [filesize kilobytes] [filecount count]
For example, the following command captures two 16,000-KByte files of
proxy-IP traffic:
bstnA(cfg)# end
bstnA# capture session 2 proxy‐all file proxyTraffic filecount 2
% INFO: Configuring network; this may take up to 6 minutes to complete.
bstnA# ...
Note
The proxy-all option is not available on ARX-VE.
Listing All Capture Files
A capture file is accessible from the “capture” directory: use show capture
to see the file listing:
show capture
For example, the following command shows several capture files:
bstnA# show capture
capture
clientCap.cap Oct 28 01:23 15 MB
nasTraffic.cap Oct 28 01:29 5.7 MB
ntaps_00001_20091028053845.cap Oct 28 01:38 24 B
proxyTraffic_02032_20091028052930.cap Oct 28 01:29 150 kB
proxyTraffic_02033_20091028052930.cap Oct 28 01:29 55 kB
shadow_usage.cap Oct 28 02:35 24 B
bstnA# ...
Showing Capture Details
The capture-file contents are the same as the output from TShark, a
commonly-used Network Analyzer. TShark is the command-line version of
Wireshark (formerly Ethereal), a graphical interface to the same
Network-Analyzer functions. To view the capture file, use show capture
file-name:
show capture file‐name
where file-name (1-1024 characters) is the name of the chosen capture
file.
CLI Maintenance Guide
9 - 19
Chapter 9
Troubleshooting Network Connections
For example, the following command sequence shows the contents of
“clientCap.cap:”
bstnA# show capture clientCap.cap
...
48672 37.714814 172.16.100.183 ‐> 192.168.25.10 NFS V3 SETATTR Call, FH:0x92090400
48673 37.715214 192.168.25.10 ‐> 172.16.100.183 NFS V3 SETATTR Reply (Call In 48672)
48674 37.715413 172.16.100.183 ‐> 192.168.25.10 NFS V3 LOOKUP Call, DH:0x04090400/hp_psaux.ver
48675 37.715663 192.168.25.10 ‐> 172.16.100.183 NFS V3 LOOKUP Reply (Call In 48674) Error:NFS3ERR_NOENT
48676 37.715762 172.16.100.183 ‐> 192.168.25.10 NFS V3 CREATE Call, DH:0x04090400/hp_psaux.ver Mode:UNCHECKED
48677 37.719208 192.168.25.10 ‐> 172.16.100.183 NFS V3 CREATE Reply (Call In 48676)
48678 37.719556 172.16.100.183 ‐> 192.168.25.10 NFS V3 WRITE Call, FH:0x98090400 Offset:0 Len:114 UNSTABLE
48679 37.720406 192.168.25.10 ‐> 172.16.100.183 NFS V3 WRITE Reply (Call In 48678) Len:114 UNSTABLE
48680 37.720505 172.16.100.183 ‐> 192.168.25.10 NFS V3 COMMIT Call, FH:0x98090400
48681 37.725897 192.168.25.10 ‐> 172.16.100.183 NFS V3 COMMIT Reply (Call In 48680)
48682 37.726146 172.16.100.183 ‐> 192.168.25.10 NFS V3 LOOKUP Call, DH:0x04090400/hp_psaux.ver
48683 37.726644 192.168.25.10 ‐> 172.16.100.183 NFS V3 LOOKUP Reply (Call In 48682), FH:0x98090400
48684 37.726745 172.16.100.183 ‐> 192.168.25.10 NFS V3 SETATTR Call, FH:0x98090400
48685 37.733885 192.168.25.10 ‐> 172.16.100.183 NFS V3 SETATTR Reply (Call In 48684)
48686 37.734333 172.16.100.183 ‐> 192.168.25.10 NFS V3 GETATTR Call, FH:0x98090400
48687 37.734533 192.168.25.10 ‐> 172.16.100.183 NFS V3 GETATTR Reply (Call In 48686) Regular File mode:0654 uid:5198 gid:1007
48688 37.736529 172.16.100.183 ‐> 192.168.25.10 NFS V3 SETATTR Call, FH:0x98090400
48689 37.736829 192.168.25.10 ‐> 172.16.100.183 NFS V3 SETATTR Reply (Call In 48688) Error:NFS3ERR_PERM
48690 37.736978 172.16.100.183 ‐> 192.168.25.10 NFS V3 GETATTR Call, FH:0x98090400
48691 37.737178 192.168.25.10 ‐> 172.16.100.183 NFS V3 GETATTR Reply (Call In 48690) Regular File mode:0654 uid:5198 gid:1007
48692 37.737278 172.16.100.183 ‐> 192.168.25.10 NFS V3 GETATTR Call, FH:0x98090400
48693 37.737477 192.168.25.10 ‐> 172.16.100.183 NFS V3 GETATTR Reply (Call In 48692) Regular File mode:0654 uid:5198 gid:1007
48694 37.737577 172.16.100.183 ‐> 192.168.25.10 NFS V3 SETATTR Call, FH:0x98090400
48695 37.738276 192.168.25.10 ‐> 172.16.100.183 NFS V3 SETATTR Reply (Call In 48694)
48696 37.738526 172.16.100.183 ‐> 192.168.25.10 NFS V3 LOOKUP Call, DH:0x04090400/nvram.stamp
48697 37.738725 192.168.25.10 ‐> 172.16.100.183 NFS V3 LOOKUP Reply (Call In 48696) Error:NFS3ERR_NOENT
...
Summarizing a Capture File
You can show a high-level summary of the IP traffic captured in one of the
above files. To show the summary, specify the capture file and use an
optional summary keyword in the show capture command:
show capture capture‐file summary [cifs | non‐cifs]
where
capture-file (1-1024 characters) is the name of the chosen capture
file.
summary specifies the output format.
cifs | non-cifs (optional) is a filter for the output. The cifs flag
shows only CIFS-related traffic (to and from the ports listed
earlier), and the non-cifs flag filters out all CIFS-related traffic.
9 - 20
Capturing IP Traffic in a File
You can only use this summary option when the capture session is stopped.
Use no capture session to stop the session, even if the session has stopped
writing to its only output file.
The output is the same as that of TShark with the -z option. It shows a table
of UDP conversations and another table of TCP conversations, followed by
separate RTT tables for NFSv2, NFSv3, and SMB (or CIFS). The first two
tables, UDP Conversations and TCP Conversations, show the numbers
of UDP frames and bytes exchanged between each pairing of IP addresses.
Each IP-address pair is typically a VIP or proxy-IP and some external
address, and appears on one line. These are followed by three tables with
RTT statistics for specific NFS-procedure calls and/or CIFS commands.
For example, the following command summarizes a capture file with UDP
conversations, TCP conversations, NFSv3 calls, and CIFS commands:
bstnA# show capture nasTraffic.cap summary
================================================================================
UDP Conversations
Filter:<No Filter>
| <‐ | | ‐> | | Total |
| Frames Bytes | | Frames Bytes | | Frames Bytes |
192.168.25.21:2049 <‐> 192.168.25.34:640 827 1029774 855 175726 1682 1205500
192.168.25.21:2049 <‐> 192.168.25.31:640 20 6972 20 3992 40 10964
192.168.25.31:640 <‐> 192.168.25.21:sunrpc 0 0 2 196 2 196
================================================================================
================================================================================
TCP Conversations
Filter:<No Filter>
| <‐ | | ‐> | | Total |
| Frames Bytes | | Frames Bytes | | Frames Bytes |
192.168.25.31:63805 <‐> 192.168.25.21:445 20 11475 26 3246 46 14721
192.168.25.55:11884 <‐> 192.168.25.21:445 11 1869 14 1981 25 3850
192.168.25.21:2049 <‐> 192.168.25.31:649 2 222 1 226 3 448
192.168.25.21:2049 <‐> 192.168.25.31:648 2 222 1 226 3 448
192.168.25.21:2049 <‐> 192.168.25.31:647 2 222 1 226 3 448
192.168.25.31:63664 <‐> 192.168.25.21:445 1 127 2 193 3 320
192.168.25.21:2049 <‐> 192.168.25.31:644 2 182 1 86 3 268
192.168.25.21:2049 <‐> 192.168.25.31:654 2 182 1 86 3 268
192.168.25.21:4046 <‐> 192.168.25.31:643 1 56 1 60 2 116
192.168.25.31:641 <‐> 192.168.25.21:sunrpc 1 60 1 56 2 116
================================================================================
===================================================================
NFS Version 2 RTT Statistics:
Filter:
Procedure Calls Min RTT Max RTT Avg RTT
NULL 0 0.00000 0.00000 0.00000
GETATTR 0 0.00000 0.00000 0.00000
SETATTR 0 0.00000 0.00000 0.00000
ROOT 0 0.00000 0.00000 0.00000
LOOKUP 0 0.00000 0.00000 0.00000
READLINK 0 0.00000 0.00000 0.00000
READ 0 0.00000 0.00000 0.00000
WRITECACHE 0 0.00000 0.00000 0.00000
WRITE 0 0.00000 0.00000 0.00000
CREATE 0 0.00000 0.00000 0.00000
REMOVE 0 0.00000 0.00000 0.00000
RENAME 0 0.00000 0.00000 0.00000
LINK 0 0.00000 0.00000 0.00000
SYMLINK 0 0.00000 0.00000 0.00000
CLI Maintenance Guide
9 - 21
Chapter 9
Troubleshooting Network Connections
MKDIR 0 0.00000 0.00000 0.00000
RMDIR 0 0.00000 0.00000 0.00000
READDIR 0 0.00000 0.00000 0.00000
STATFS 0 0.00000 0.00000 0.00000
===================================================================
===================================================================
NFS Version 3 RTT Statistics:
Filter:
Procedure Calls Min RTT Max RTT Avg RTT
NULL 7 0.00005 0.00127 0.00048
GETATTR 92 0.00004 0.00214 0.00036
SETATTR 2 0.00099 0.03040 0.01570
LOOKUP 70 0.00004 0.00445 0.00042
ACCESS 0 0.00000 0.00000 0.00000
READLINK 0 0.00000 0.00000 0.00000
READ 2 0.00014 0.02093 0.01053
WRITE 652 0.00017 0.11836 0.00512
CREATE 0 0.00000 0.00000 0.00000
MKDIR 0 0.00000 0.00000 0.00000
SYMLINK 0 0.00000 0.00000 0.00000
MKNOD 0 0.00000 0.00000 0.00000
REMOVE 2 0.00023 0.00025 0.00024
RMDIR 0 0.00000 0.00000 0.00000
RENAME 0 0.00000 0.00000 0.00000
LINK 0 0.00000 0.00000 0.00000
READDIR 2 0.00030 0.00815 0.00422
READDIRPLUS 0 0.00000 0.00000 0.00000
FSSTAT 8 0.00009 0.00379 0.00099
FSINFO 1 0.00014 0.00014 0.00014
PATHCONF 0 0.00000 0.00000 0.00000
COMMIT 0 0.00000 0.00000 0.00000
===================================================================
===================================================================
SMB RTT Statistics:
Filter:
Commands Calls Min RTT Max RTT Avg RTT
Echo 1 0.00011 0.00011 0.00011
Tree Disconnect 2 0.00038 0.00079 0.00059
Negotiate Protocol 2 0.00093 0.00684 0.00389
Session Setup AndX 4 0.00768 0.09215 0.03479
Logoff AndX 2 0.00074 0.00124 0.00099
Tree Connect AndX 2 0.00023 0.00174 0.00099
Transaction2 Commands Calls Min RTT Max RTT Avg RTT
FIND_FIRST2 2 0.00050 0.00264 0.00157
QUERY_FS_INFO 4 0.00009 0.00189 0.00103
QUERY_PATH_INFO 2 0.00124 0.00189 0.00157
NT Transaction Commands Calls Min RTT Max RTT Avg RTT
===================================================================
bstnA# ...
Showing All Capture Sessions
Use the show capture sessions command to show the current status of all
capture sessions, if any are running:
show capture sessions
9 - 22
Capturing IP Traffic in a File
For example, the following command shows two active capture sessions:
bstnA# show capture sessions
Session Ip Additional Ip VLAN File Size File Count ‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
2 proxy‐all proxy‐all 25 100 2 3 n/a 192.168.25.21 25 100 3 Session State File Name
‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2 Capturing proxyTraffic 3 Capturing nasTraffic bstnA#
Merging the Files from a Multi-File Capture
If you created multiple files from a single capture session and preserved
them as separate files, you can later use the capture merge command to
merge them into a single file. The capture session command may produce
multiple capture files if the ARX reboots in the middle of the session, or if
someone stops the capture session with the no-merge option (described
earlier). The merge operation sorts all of the captured packets into
chronological order, starting with the earliest.
Like the capture session command, you can invoke capture merge from
priv-exec mode:
capture merge file prefix
where prefix (1-256 characters) is the prefix that is common to the files
that you want to merge. This is typically the same prefix used to create
the files in the capture session command. This is also the name of the
output file created by the merge operation (prefix.cap).
For example, the following command sequence shows four capture files,
merges two of them from the same session, and then shows that there are
three files remaining:
bstnA(cfg)# end
bstnA# show capture
capture
clientCap.cap Oct 27 14:32 15 MB
nasTraffic.cap Oct 27 14:37 6.0 MB
proxyTraffic_01352_20091027183657.cap Oct 27 14:37 151 kB
proxyTraffic_01353_20091027183700.cap Oct 27 14:37 42 kB
bstnA# capture merge file proxyTraffic
% INFO: Merging 2 capture files into proxyTraffic.cap; this may take up to 1 minute to complete.
bstnA# show capture
capture
clientCap.cap Oct 27 14:32 15 MB
nasTraffic.cap Oct 27 14:37 6.0 MB
CLI Maintenance Guide
9 - 23
Chapter 9
Troubleshooting Network Connections
proxyTraffic.cap Oct 27 14:57 193 kB
bstnA# ...
Copying the Capture File(s) to a Remote Site
You can send all of your packet-capture files back to a remote site (or F5
Support) for a detailed analysis. On the remote machine, you can use the
graphical Wireshark program or the CLI-based TShark program to view the
capture file(s). The ARX formats its packet-capture files to be legible by any
program that supports the Packet Capture (Pcap, or WinPcap) library.
You can use the collect command to collect all packet-capture files, along
with other diagnostic information, and send them to a remote site through
FTP, SCP, or e-mail. This is described in Collecting Diagnostic
Information, on page 8-30. To collect only the packet-capture files, use the
collect capture command (from Collecting Partial Information, on page
8-34).
9 - 24
Configuring Port Mirroring
Configuring Port Mirroring
You can also monitor all of the traffic on a specific port, using an external
packet analyzer. Port mirroring captures all packets going through
designated source interface(s) and copies them to the “MIRROR” interface.
A network analyzer at the “MIRROR” interface can therefore see all traffic
going through the source interface(s) in real time.
Important
Oversubscription of the destination monitor port during port mirroring can
result in a service interruption. Proceed only upon advice from F5 Support.
Port mirroring is not supported on the ARX-500. The ARX-2000 and
ARX-4000 support port mirroring, but neither has a separate MIRROR port;
for these types of chassis, send the packets to another client/server interface
(as described in the subsection below).
From cfg mode, use the monitor system command to monitor one source
interface:
monitor system source‐interface slot/port {rx | tx | both}
where
slot/port is the source port. Use the show interface summary
command to find all ports configured on the ARX.
{rx | tx | both} chooses the direction of monitored packets. Choose
rx for received (ingress) packets, tx for transmit (egress) packets,
or both.
A notice appears, cautioning you against excessive traffic through the
MIRROR port (similar to the Important note above). Enter yes to continue.
Important
Remember to shut off port mirroring after you have finished diagnosing
your problem. Port mirroring slows the source interface(s) with numerous
packet selection, duplication, and forwarding operations.
Monitor sessions do not persist across reboots.
Using an Alternative Destination Interface
You can optionally use another external interface as the destination instead
of the “MIRROR” interface. This is your only option with the ARX-2000
and ARX-4000, which have no separate “MIRROR” interface. From cfg
mode, use the destination-interface clause at the end of the monitor module
command:
monitor module source‐interface slot/port {rx | tx | both} destination‐interface slot/port
where
CLI Maintenance Guide
9 - 25
Chapter 9
Troubleshooting Network Connections
source-interface slot/port is the source port (for example,
“source-interface 2/9” on an ARX-4000). Use the show interface
summary command to find all ports configured on the ARX.
{rx | tx | both} chooses the direction of monitored packets. Choose
rx for received (ingress) packets, tx for transmit (egress) packets,
or both.
destination-interface slot/port is the destination port where the
network analyzer is connected (for example, “destination-interface
1/6”). Choose a destination port with equal or greater bandwidth
than the source port.
You can monitor one source port at a time with monitor module; use monitor
system (above) to monitor multiple source ports. As with monitor system, a
prompt warns you not to overwhelm the destination port; enter yes to
continue.
For example, the following command sequence monitors packets on port
2/4, duplicating the packets for a network analyzer on port 2/6:
bstnA(cfg)# monitor module source‐interface 2/4 both destination‐interface 2/6
Warning: Oversubscription of the destination monitor port may result in a service interruption. Proceed only upon advice from Technical Support.
Are you sure? [yes/no] yes
bstnA(cfg)# ...
Showing Active Port-Mirroring Sessions
Use the show monitor command to view the current state of any active
monitor session:
show monitor
For example, the following command sequence shows one active monitor
session:
bstnA(cfg)# show monitor
Monitor Session: System
Source : Slot 2 Port 4
Destination :Slot 2 Port 6
Mode: Both bstnA(cfg)# ...
Shutting Down Port Mirroring
Remember to shut off port-mirroring sessions when you are not actively
monitoring them. Port mirroring puts a strain on port performance. Use the
no monitor command to shut down a monitor session:
no monitor {system | module}
{system | module} chooses the type of monitor session to shut down.
9 - 26
Configuring Port Mirroring
For example, the following command sequence shuts down a monitor
module session:
bstnA(cfg)# no monitor module
bstnA(cfg)# ...
Shutting Down Mirroring for One Source Port
Recall that you can use monitor system to monitor more than one port. For
the multi-port case, you can use no monitor system to selectively disable one
source port:
no monitor system source‐interface slot/port
where slot/port is the source port to stop monitoring (for example,
“source-interface 1/5”).
For example, the following command sequence stops monitoring port 2/3:
bstnA(cfg)# no monitor system source‐interface 2/3
bstnA(cfg)# ...
CLI Maintenance Guide
9 - 27
Chapter 9
Troubleshooting Network Connections
Showing Filer-Connection Statistics
To see cumulative statistics for filer connections, you can use the show
statistics filer connections command:
show statistics filer connections
The output is a table with one row per filer. Each row shows the current
connects and the maximum connections since the last reboot of the ARX.
For example:
bstnA# show statistics filer connections
Connections
Filer Current Max
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐
das1 0 4
fs1 4 10
fs2 4 11
fs3 2 3
fs4 3 14
fs5 2 9
das2 0 4
das3 0 4
nas1 72 76
das7 0 4
das8 0 4
nas2 4 4
nas3 4 4
nas10 4 26
nasE1 6 8
smb1 0 0
Focusing On a Particular Filer
You can use the name of a particular filer at the end of the command to
focus on the connection statistics for one filer. You can also specify a
particular network processor:
show statistics filer connections filer‐name [processor slot.proc]
where
filer-name (optional, 1-64 characters) identifies an external filer by
the name defined on the ARX. For a complete list of filer names,
use the show external-filer command (see Listing External Filers,
on page 6-18 of the ARX® CLI Storage-Management Guide).
processor slot.proc (optional) focuses the output on a particular
network processor. Use show processors for a complete list of
processors (and their modules and slots) on the ARX.
The output is two tables, one for CIFS connections and one for NFS
connections. The CIFS table breaks down the statistics between data-plane
connections (directly from ARX clients) and control-plane connections
(which go through one or more processes on the ACM or ASM), and shows
counters for client sessions within the data-plane connections. If you choose
the processor option, the output is similar but with a more-limited scope.
9 - 28
Showing Filer-Connection Statistics
For example, this command shows the connection statistics for the “fs2”
filer:
bstnA# show statistics filer fs2 connections
Filer (192.168.25.27) All processors
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
CIFS:
Connection limit: none
Current data connections: 0
Current control connections: 5
Max connections (data+control): 13
Time of Max connections: Thu Sep 16 00:54:17 2010
Current data sessions: 0
Max data sessions: 0
Time of Max data sessions: n/a
Max sessions per data connection: 0
Time of Max sessions/connections: n/a
NFS:
Current connections: 0
Max connections: 0
Time of Max connections: n/a
bstnA# ...
Clearing the Filer-Connection Statistics
You can use the clear statistics filer connections command to clear the
filer-connection statistics from the ARX database. This reduces all of the
“Max” statistics to the current counts. Rebooting the ARX has the same
effect. You can clear these statistics from priv-exec mode:
clear statistics filer [filer‐name] connections
where filer-name (optional, 1-64 characters) identifies a single external
filer. This clears only the connection statistics that pertain to a single
filer. Use the filer name defined on the ARX. For a complete list of filer
names, use the show external-filer command (see Listing External
Filers, on page 6-18 of the ARX® CLI Storage-Management Guide).
The CLI prompts for confirmation before clearing any connection statistics;
enter yes to proceed.
For example, this command sequence clears the connection statistics for the
“fs2” filer, and then shows that the “Max” counts now match the “Current”
counts:
bstnA# clear statistics filer fs2 connections
Clear the connection statistics on filer 'fs2'.
CLI Maintenance Guide
9 - 29
Chapter 9
Troubleshooting Network Connections
Are you sure? [yes/no] yes
bstnA# show statistics filer fs2 connections
Filer (192.168.25.27) All processors
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
CIFS:
Connection limit: none
Current data connections: 0
Current control connections: 5
Max connections (data+control): 5
Time of Max connections: Thu Sep 16 00:58:09 2010
Current data sessions: 0
Max data sessions: 0
Time of Max data sessions: n/a
Max sessions per data connection: 0
Time of Max sessions/connections: n/a
NFS:
Current connections: 0
Max connections: 0
Time of Max connections: n/a
bstnA#
Dropping All Connections to a Filer
If a back-end filer is overwhelmed with TCP connections, you can forcibly
drop all connections to the filer at once. This can occur after you reduce the
limit on CIFS connections to the filer (see Limiting CIFS Connections to the
Filer, on page 6-10 of the ARX® CLI Storage-Management Guide); new
clients cannot connect until the number of current connections drops below
the new limit.
Dropping TCP connections may cause a noticeable interruption for your
currently-connected clients. From priv-exec mode, you can use drop
filer-connections to close all TCP sessions with a particular filer:
drop filer‐connections filer‐name [processor slot.processor]
where
filer-name (1-64 characters) identifies a single external filer. Use
the filer name defined on the ARX. For a complete list of filer
names, use the show external-filer command (see Listing External
Filers, on page 6-18 of the ARX® CLI Storage-Management
Guide).
slot.processor identifies a single NSM processor.
9 - 30
Showing Filer-Connection Statistics
The CLI prompts for confirmation before dropping all connections; enter
yes to proceed.
For example, this command sequence drops all connections to the “smb1”
filer:
bstnA# drop filer‐connections smb1
Drop the connections to filer smb1.
Proceed? [yes/no] yes
bstnA#
CLI Maintenance Guide
9 - 31
Chapter 9
Troubleshooting Network Connections
9 - 32
10
Troubleshooting Managed Volumes
• Overview
• Showing Share Statistics
• Showing Metadata Statistics
• Draining One or More Shares
• Removing an Imported Share
• Correcting Share-Import Errors
• Removing a Full Namespace Service
• Managing Namespace Collisions
• Managing Collisions With CIFS 8.3 Names
• Fixing File/Directory Names with Trailing Periods
• Finding NFS-Only Entries in a Multi-Protocol
Volume
• Migrations in a Multi-Protocol Namespace
• Showing Policy History for a Volume
• Addressing Inconsistent Directory Attributes
Overview
Overview
This chapter describes how to
• show usage statistics for managed volumes,
• remove shares from them,
• correct share-import errors,
• cleanly remove a namespace and all of its associated configuration
objects,
• manage file collisions after an import,
• fix file- and directory-naming issues in a CIFS namespace,
• fix file- and directory-naming issues in a multi-protocol namespace,
• find the exact location of a file on your back-end storage
• show policy usage and history, and
• address inconsistent directory attributes.
This extends the previous chapters, which described tools for collecting
diagnostic information and troubleshooting network connections.
CLI Maintenance Guide
10 - 3
Chapter 10
Troubleshooting Managed Volumes
Showing Share Statistics
The ARX records read/write statistics, including latency measures, for each
of its filer shares. It keeps these statistics from the moment each share is
“enabled” as part of an ARX volume. (For instructions on configuring and
enabling a volume share, refer to the ARX® CLI Storage-Management
Guide: Adding a Share, on page 8-8 for direct volumes, or Adding a Share,
on page 9-33 for managed volumes.) The statistics are kept at the NSM,
which runs the ARX’s fastpath processes. Use the show statistics
namespace fastpath command to see these statistics:
show statistics namespace fastpath
For example, the following command shows usage statistics for all filer
shares:
bstnA> show statistics namespace fastpath
Share Statistics Summary:
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace : "medco", Share Name: "corporate"
Volume : "/vol"
Filer: "nas1"
NFS Export: "/vol/vol1/direct"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 0.39 MilliSeconds
Other Calls: 259 Total
All Calls: 259 Total
Namespace : "medco", Share Name: "sales"
Volume : "/vol"
Filer: "nas2"
NFS Export: "/vol/vol1/direct"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 0.00 MilliSeconds
Other Calls: 0 Total
All Calls: 0 Total
Namespace : "medco", Share Name: "generic"
Volume : "/vol"
Filer: "nas3"
NFS Export: "/vol/vol2/direct"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 0.61 MilliSeconds
Other Calls: 5,591 Total
All Calls: 5,591 Total
Namespace : "wwmed", Share Name: "budget"
Volume : "/acct"
10 - 4
Showing Share Statistics
Filer: "das1"
NFS Export: "/exports/budget"
Read: 316,814,863 Bytes
Read Calls: 56,074 Total
Write: 7,277,751 Bytes
Write Calls: 944 Total
Average Latency: 0.32 MilliSeconds
Other Calls: 27,101 Total
All Calls: 84,119 Total
Namespace : "wwmed", Share Name: "bills"
Volume : "/acct"
Filer: "das8"
NFS Export: "/work1/accting"
Read: 33,220,892 Bytes
Read Calls: 5,915 Total
Write: 3,797,298 Bytes
Write Calls: 526 Total
Average Latency: 1.74 MilliSeconds
Other Calls: 5,434 Total
All Calls: 11,875 Total
Namespace : "wwmed", Share Name: "bills2"
Volume : "/acct"
Filer: "das3"
NFS Export: "/data/acct2"
Read: 17,429,055 Bytes
Read Calls: 3,071 Total
Write: 88,619 Bytes
Write Calls: 15 Total
Average Latency: 1.38 MilliSeconds
Other Calls: 4,547 Total
All Calls: 7,633 Total
Namespace : "wwmed", Share Name: "it5"
Volume : "/acct"
Filer: "das7"
NFS Export: "/lhome/it5"
Read: 94,401,546 Bytes
Read Calls: 16,687 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 3.07 MilliSeconds
Other Calls: 2,734 Total
All Calls: 19,421 Total
Namespace : "medarcv", Share Name: "rx"
Volume : "/rcrds"
Filer: "fs4"
CIFS Share: "prescriptions"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 0.41 MilliSeconds
Other Calls: 31 Total
All Calls: 31 Total
CLI Maintenance Guide
10 - 5
Chapter 10
Troubleshooting Managed Volumes
Namespace : "medarcv", Share Name: "charts"
Volume : "/rcrds"
Filer: "fs1"
CIFS Share: "histories"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 2.00 MilliSeconds
Other Calls: 35 Total
All Calls: 35 Total
Namespace : "medarcv", Share Name: "bulk"
Volume : "/rcrds"
Filer: "fs2"
CIFS Share: "bulkstorage"
Read: 0 Bytes
Read Calls: 0 Total
Write: 81,714 Bytes
Write Calls: 6 Total
Average Latency: 0.54 MilliSeconds
Other Calls: 30 Total
All Calls: 36 Total
Namespace : "medarcv", Share Name: "equip"
Volume : "/lab_equipment"
Filer: "nas10"
CIFS Share: "equipment"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 0.00 MilliSeconds
Other Calls: 0 Total
All Calls: 0 Total
Namespace : "medarcv", Share Name: "leased"
Volume : "/lab_equipment"
Filer: "nas10"
CIFS Share: "for_lease"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 0.00 MilliSeconds
Other Calls: 0 Total
All Calls: 0 Total
Namespace : "medarcv", Share Name: "chemistry"
Volume : "/test_results"
Filer: "fs1"
CIFS Share: "chem_results"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
10 - 6
Showing Share Statistics
Average Latency: 0.00 MilliSeconds
Other Calls: 0 Total
All Calls: 0 Total
Namespace : "medarcv", Share Name: "hematology"
Volume : "/test_results"
Filer: "fs3"
CIFS Share: "hematology_results"
Read: 0 Bytes
Read Calls: 0 Total
Write: 0 Bytes
Write Calls: 0 Total
Average Latency: 0.00 MilliSeconds
Other Calls: 0 Total
All Calls: 0 Total
Namespace : "insur", Share Name: "shr1‐next"
Volume : "/claims"
Filer: "nasE1"
NFS Export: "/root_vdm_4/patient_records"
CIFS Share: "patient_records"
Read: 312,787,245 Bytes
Read Calls: 56,360 Total
Write: 4,992,738 Bytes
Write Calls: 617 Total
Average Latency: 0.82 MilliSeconds
Other Calls: 6,180 Total
All Calls: 63,157 Total
bstnA>
Showing Share Statistics from One Namespace
To focus on the share statistics from one namespace, use the namespace
argument in the show statistics namespace command, followed by the
fastpath keyword:
show statistics namespace name fastpath
where
name (1-30 characters) identifies the desired namespace, and
fastpath is a required keyword.
For example, the following command shows share statistics for the
“wwmed” namespace:
bstnA> show statistics namespace wwmed fastpath
Share Statistics Summary:
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace : "wwmed", Share Name: "budget"
Volume : "/acct"
Filer: "das1"
NFS Export: "/exports/budget"
Read: 316,814,863 Bytes
Read Calls: 56,074 Total
Write: 7,277,751 Bytes
CLI Maintenance Guide
10 - 7
Chapter 10
Troubleshooting Managed Volumes
Write Calls: 944 Total
Average Latency: 0.32 MilliSeconds
Other Calls: 27,101 Total
All Calls: 84,119 Total
Namespace : "wwmed", Share Name: "bills"
Volume : "/acct"
Filer: "das8"
NFS Export: "/work1/accting"
Read: 33,220,892 Bytes
Read Calls: 5,915 Total
Write: 3,797,298 Bytes
Write Calls: 526 Total
Average Latency: 1.74 MilliSeconds
Other Calls: 5,434 Total
All Calls: 11,875 Total
Namespace : "wwmed", Share Name: "bills2"
Volume : "/acct"
Filer: "das3"
NFS Export: "/data/acct2"
Read: 17,429,055 Bytes
Read Calls: 3,071 Total
Write: 88,619 Bytes
Write Calls: 15 Total
Average Latency: 1.38 MilliSeconds
Other Calls: 4,547 Total
All Calls: 7,633 Total
bstnA>
Showing Statistics from One Volume
You can narrow the focus further to a particular volume. After the
namespace name, add the volume path to the show statistics namespace
command:
show statistics namespace name volume fastpath
where
name (1-30 characters) identifies the desired namespace,
volume (1-1024 characters) identifies the volume, and
fastpath is a required keyword.
For example, the following command shows share statistics from the
“wwmed~/acct” volume:
bstnA> show statistics namespace wwmed /acct fastpath
Share Statistics Summary:
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace : "wwmed", Share Name: "budget"
Volume : "/acct"
Filer: "das1"
NFS Export: "/exports/budget"
Read: 316,814,863 Bytes
Read Calls: 56,074 Total
Write: 7,277,751 Bytes
10 - 8
Showing Share Statistics
Write Calls: 944 Total
Average Latency: 0.32 MilliSeconds
Other Calls: 27,101 Total
All Calls: 84,119 Total
Namespace : "wwmed", Share Name: "bills"
Volume : "/acct"
Filer: "das8"
...
bstnA>
Focusing on One Share
You can narrow the focus down to a single share in the volume. After the
volume path, add the share name to the show statistics namespace
command:
show statistics namespace name volume share‐name fastpath
where
name (1-30 characters) identifies the desired namespace,
volume (1-1024 characters) identifies the volume,
share-name (1-64 characters) identifies the specific share, and
fastpath is a required keyword.
For example, the following command shows share statistics from the
“budget” share in the “wwmed~/acct” volume:
bstnA> show statistics namespace wwmed /acct budget fastpath
Share Statistics Summary:
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Namespace : "wwmed", Share Name: "budget"
Volume : "/acct"
Filer: "das1"
NFS Export: "/exports/budget"
Read: 316,814,863 Bytes
Read Calls: 56,074 Total
Write: 7,277,751 Bytes
Write Calls: 944 Total
Average Latency: 0.32 MilliSeconds
Other Calls: 27,101 Total
All Calls: 84,119 Total
bstnA>
CLI Maintenance Guide
10 - 9
Chapter 10
Troubleshooting Managed Volumes
Showing Metadata Statistics
A managed volume stores metadata about the files that it contains at the
back-end. In order for the managed volume to perform effectively, the
latency between the managed volume software running on the ARX and the
filer share on which the metadata resides must be low. The show statistics
metadata command enables you to display a number of metadata read and
write statistics for each managed volume associated with the ARX.
The command syntax is:
show statistics metadata [namespace name [volume volumepath]]
where name specifies a namespace for which to display metadata statistics,
and volumepath species a volume for which to display metadata statistics.
An example of the output from this command follows:
bstnA# show statistics metadata
Namespace: wwmed
Volume: /acct
Location: nas1 /vol/vol1/meta1
Last Reset Time: 07/22/2011 08:32:14 ‐0400
Read Operations: 18
Read Response Time: 2.89 usec/op
Read Bytes: 52224
Read Rate: 1004.31 MB/s
Read Errors: 0
Read Operations In Progress: 0
Last Read Operation: 07/22/2011 08:32:14 ‐0400
Write Operations: 7921
Write Response Time: 85.07 usec/op
Write Bytes: 7001600
Write Rate: 10.39 MB/s
Write Errors: 0
Write Operations In Progress: 0
Last Write Operation: 07/22/2011 09:11:50 ‐0400
Namespace: medarcv
Volume: /lab_equipment
Location: nas1 /vol/vol1/meta6
Last Reset Time: 07/22/2011 08:33:03 ‐0400
Read Operations: 28
Read Response Time: 2.71 usec/op
Read Bytes: 57344
Read Rate: 754.53 MB/s
Read Errors: 0
Read Operations In Progress: 0
Last Read Operation: 07/22/2011 08:46:13 ‐0400
Write Operations: 63
Write Response Time: 830.67 usec/op
Write Bytes: 211456
Write Rate: 4.04 MB/s
Write Errors: 0
Write Operations In Progress: 0
10 - 10
Showing Metadata Statistics
Last Write Operation: 07/22/2011 09:12:55 ‐0400
Namespace: medarcv
Volume: /rcrds
Location: nas1 /vol/vol1/meta3
Last Reset Time: 07/22/2011 08:32:51 ‐0400
Read Operations: 28
Read Response Time: 2.36 usec/op
Read Bytes: 57344
Read Rate: 868.85 MB/s
Read Errors: 0
Read Operations In Progress: 0
Last Read Operation: 07/22/2011 08:51:12 ‐0400
Write Operations: 106
Write Response Time: 1422.67 usec/op
Write Bytes: 358912
Write Rate: 2.38 MB/s
Write Errors: 0
Write Operations In Progress: 0
Last Write Operation: 07/22/2011 09:12:53 ‐0400
Namespace: insur
Volume: /claims
Location: nas1 /vol/vol1/meta2
Last Reset Time: 07/22/2011 08:51:36 ‐0400
Read Operations: 18
Read Response Time: 3.72 usec/op
Read Bytes: 52224
Read Rate: 779.46 MB/s
Read Errors: 0
Read Operations In Progress: 0
Last Read Operation: 07/22/2011 08:51:36 ‐0400
Write Operations: 53
Write Response Time: 518.43 usec/op
Write Bytes: 195584
Write Rate: 7.12 MB/s
Write Errors: 0
Write Operations In Progress: 0
Last Write Operation: 07/22/2011 09:03:35 ‐0400
bstnA#
Execute the command clear statistics metadata to clear and reset
metadata counters for the entire system, or for a specified namespace or
volume.
CLI Maintenance Guide
10 - 11
Chapter 10
Troubleshooting Managed Volumes
Draining One or More Shares
To remove a share from a managed volume with snapshots, you must drain
it of all files, wait for all of its back-end snapshots to age out, and then
remove the share from the ARX configuration. Volumes without snapshots
can use a simpler method, described in the next section. Skip to the next
section to remove a share from a managed volume without any snapshot
support.
You can move all files from one share (or share farm) to one or more other
shares in the same volume, thereby draining the source share(s). A
placement rule accomplishes this, and prevents any new files from being
created on the source share(s). A placement rule is typically used for moving
files to their storage tiers, as described in Placing Files on Particular
Shares, on page 14-4 of the ARX® CLI Storage-Management Guide. This is
a special use case for a placement rule.
Use place-rule to create a new placement rule, as described in the storage
manual. This puts you into gbl-ns-vol-plc mode, where you must choose a
source share or share farm, set the storage target for the files, and enable the
rule. There are also some optional commands you can invoke from this
mode. This section explains the options that are relevant to draining a share.
For example, the following command sequence creates an empty placement
rule, “emptyRH,” for the namespace, “wwmed:”
bstnA(gbl)# namespace wwmed volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# place‐rule emptyRH
This will create a new policy object.
Create object 'emptyRH'? [yes/no] yes
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# ...
Identifying the Source Share(s)
The next step in draining a share or shares is to identify them. The
placement rule places all files from the source share(s) onto the target
storage. From gbl-ns-vol-plc mode, use the source command to specify the
source share(s).
From gbl-ns-vol-plc mode, use one of two source commands to specify the
source share(s):
source share share‐name
where share share-name (1-64 characters) identifies a single
source share, or
source share‐farm share‐farm‐name
where share-farm-name (1-64 characters) is a group of shares in a
share farm.
Use the show global-config namespace command to see the shares or share
farms in each volume: see Showing Namespace Configuration, on page 7-24
of the ARX® CLI Storage-Management Guide.
10 - 12
Draining One or More Shares
For example, the following command set selects the “it5” share:
bstnA(gbl)# namespace wwmed volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# place‐rule emptyRH
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# source share it5
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# ...
Choosing the Target Storage
The next step in draining shares is to choose the target storage for the
share’s files. You can choose one target: another share or share farm in the
current volume. From gbl-ns-vol-plc mode, use the target rule to set the
share’s storage target.
For example, the following command sequence selects a share farm, “fm1,”
as the target for the “emptyRH” placement rule:
bstnA(gbl)# namespace wwmed volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# place‐rule emptyRH
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# target share‐farm fm1
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# ...
As another example, the following command sequence selects a share,
“nas3,” as the new home for all files in the source share:
bstnA(gbl)# namespace archives volume /etc
bstnA(gbl‐ns‐vol[archives~/etc])# place‐rule move2nas
bstnA(gbl‐ns‐vol‐plc[archives~/etc~move2nas])# target share nas3
bstnA(gbl‐ns‐vol‐plc[archives~/etc~move2nas])# ...
Balancing Capacity in a Target Share Farm
When a share farm is a file-placement target, the first configured share in the
farm is the default share for placed files. Most files are placed on the same
share as their parent directory, but a file defaults to the first share if its
parent directory is outside the share farm. The first share in the farm can
therefore take a heavier file burden over time.
To migrate files off of any share that is running low on free space, you can
configure auto migration for the share farm. Refer to Auto Migrating
Existing Files, on page 15-15 of the ARX® CLI Storage-Management
Guide.
Setting Other Placement-Rule Options
Other options for a file-placement rule may also be of use at your site,
though they are not directly relevant to draining a share. These include:
• migrate close-file
to close any files held open by CIFS clients, thereby making it possible to
migrate them. For details, refer to Automatically Closing All Open Files
(CIFS), on page 14-14 of the ARX® CLI Storage-Management Guide.
• limit-migrate
CLI Maintenance Guide
10 - 13
Chapter 10
Troubleshooting Managed Volumes
to control the bandwidth used for migrations. For details, refer to
Limiting Each Migration (optional), on page 14-17 of the same storage
guide.
• report
to create a progress report for the drain operation. This is recommended.
For details, refer to Configuring Progress Reports, on page 14-21 of the
storage guide.
For example, the following command sequence limits the migration
bandwidth to 10G and sends the migration results to a report:
bstnA(gbl)# namespace wwmed volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# place‐rule emptyRH
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# limit‐migrate 10G
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# report emptyRH_ verbose
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# ...
Retaining Copies of Files on the Share (optional)
Before you enable the rule and start draining the share, you have the option
to retain copies of those files. From gbl-ns-vol-shr mode, use the migrate
retain-files command to put this safeguard in place:
migrate retain‐files
The file copies go to a hidden directory, “~acopia_msnap,” at the root of the
share. To restore the files later, you can access the back-end share directly
(it is not included in the volume).
Important
Do not use this command for a share in a share farm. If a
share-farm-balancing policy tries to move files off of this share, this
placement rule makes copies of them, thereby ensuring that the share’s free
space never actually changes. The balancing policy will therefore move files
off of the share indefinitely, unnecessarily occupying space on other shares.
Use this only as a safeguard when draining all files from a single share.
For example, the following command sequence retains all migrated files in
the it5 share:
bstnA(gbl)# namespace wwmed volume /acct share it5
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~it5])# migrate retain‐files
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~it5])# ...
Disabling File Retention
To disable the feature that retains copies of migrated files, use the no form
of the command:
no migrate retain‐files
For example, the following command sequence disables the migration
safeguard in the it5 share:
bstnA(gbl)# namespace wwmed volume /acct share it5
10 - 14
Draining One or More Shares
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~it5])# no migrate retain‐files
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~it5])# ...
Making the Rule Tentative
A tentative rule is configured to appear in the system logs (syslog) as
“tentative,” showing the potential effects of the rule if it was enabled. (The
log component, POLICY_ACTION, creates the syslog messages; syslog
access and log components are described in Accessing the Syslog, on page
8-7.) If you configured reporting for the rule (as shown above), the report
shows which files would be migrated if the rule was fully enabled. Tentative
rules do not change policy enforcement, but they do consume processing
time in the policy software. From gbl-ns-vol-plc mode, use the tentative
command to put the placement rule in a tentative state:
tentative
To see the simulated rule run, you must enable the rule (as described below).
Then use show logs syslog or grep pattern logs syslog to view the syslog.
For example, the following command sequence makes the “emptyRH” rule
tentative:
bstnA(gbl)# namespace wwmed volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# place‐rule emptyRH
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# tentative
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# ...
Removing the Tentative State
Use the no tentative command to fully activate the drain rule. You can then
disable and re-enable the rule (as described below) to start the draining
process. For example, the following command sequence activates the
“emptyRH” rule. When the rule is enabled, it performs actual migrations:
bstnA(gbl)# namespace wwmed volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# place‐rule emptyRH
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# no tentative
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# ...
Enabling the Drain Rule
The final step in draining a share is to enable its placement rule. By default,
the rule is disabled and ignored by policy software. Use the enable
command to enable the rule. For example, the following command sequence
enables the “emptyRH” rule:
bstnA(gbl)# namespace wwmed volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# place‐rule emptyRH
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# enable
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# ...
CLI Maintenance Guide
10 - 15
Chapter 10
Troubleshooting Managed Volumes
Disabling the Rule
Disabling the rule removes it from consideration. Use no enable from
gbl-ns-vol-plc mode to disable a placement rule. For example, the following
command sequence disables the “emptyRH” rule:
bstnA(gbl)# namespace wwmed volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# place‐rule emptyRH
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# no enable
bstnA(gbl‐ns‐vol‐plc[wwmed~/acct~emptyRH])# ...
Verifying That All Files Are Removed
You can use a metadata-only report to verify that the share is empty. Use the
nsck ... metadata-only command to generate a report about the share (as
described in Focusing on One Share, on page 7-10), and then use show
reports to view the report. For example, the following command sequence
generates a report on the “it5” share, proving that it has no files:
bstnA(gbl)# nsck wwmed report metadata‐only share it5
Scheduling report: metadata_only.10.rpt on switch bstnA
bstnA(gbl)# show reports metadata_only.10.rpt
**** Metadata‐Only Report: Started at Fri Nov 13 01:28:37 2009 ****
**** Software Version: 5.01.000.11919 (Nov 6 2009 22:21:42) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: wwmed
**** Volume: /acct
**** Path: /acct
**** Share: it5
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[it5 ] 192.168.25.24:/lhome/it5
**** Legend:
**** FL = File: The reported entry is a file.
**** DR = Directory: The reported entry is a directory.
**** SL = Symlink: The reported entry is a symbolic link.
**** LN = Link: The reported entry has a link count greater than one.
**** NL = No Lock: Was unable to lock parent directory during report.
**** CC = NFS case‐blind name collision.
**** IC = Name contains invalid CIFS characters.
**** FN = Name may conflict with a filer‐generated name.
**** SP = A persistent split is registered in the metadata, due to a FGN.
**** NF = Name is only accessible to NFS clients.
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ DR ] [it5 ] /docs
[ DR ] [it5 ] /docs/masterIndex
[ DR ] [it5 ] /docs/HW_InstallA5C
[ DR ] [it5 ] /docs/common
[ DR ] [it5 ] /docs/SLM_Beta
[ DR ] [it5 ] /docs/snmpRef
[ DR ] [it5 ] /docs/license
[ DR ] [it5 ] /docs/HW_InstallA1K
[ DR ] [it5 ] /docs/GUIHelp
[ DR ] [it5 ] /docs/cliReference
[ DR ] [it5 ] /docs/SecureAgent
10 - 16
Draining One or More Shares
[ DR ] [it5 ] /docs/logCatalog
[ DR ] [it5 ] /docs/ReleaseNotes
[ DR ] [it5 ] /docs/useCases
[ DR ] [it5 ] /docs/Glossary
[ DR ] [it5 ] /docs/architecture
[ DR ] [it5 ] /docs/Quickstart_CardA1K
[ DR ] [it5 ] /docs/cliOperator
[ DR ] [it5 ] /docs/GUI
[ DR ] [it5 ] /docs/sitePlanning
[ DR ] [it5 ] /docs/HW_Install
[ DR ] [it5 ] /docs/Quickstart_Card
[ DR ] [it5 ] /docs/done_cli_cmds
[ DR ] [it5 ] /docs/done_ref_
[ DR ] [it5 ] /docs/GUIHelp/Temp
[ DR ] [it5 ] /docs/GUIHelp/Output
[ DR ] [it5 ] /docs/GUIHelp/Support
[ DR ] [it5 ] /docs/Glossary/Frame_files
[ DR ] [it5 ] /docs/HW_Install/HW_Book
[ DR ] [it5 ] /docs/HW_InstallA1K/HW_Book
[ DR ] [it5 ] /docs/HW_InstallA5C/HW_Book
[ DR ] [it5 ] /docs/SecureAgent/Framefiles
[ DR ] [it5 ] /docs/GUIHelp/Output/images
[ DR ] [it5 ] /docs/GUIHelp/Support/images
[ DR ] [it5 ] /docs/useCases/multiTier
[ DR ] [it5 ] /docs/useCases/specialCases
[ DR ] [it5 ] /docs/useCases/singleTier
[ DR ] [it5 ] /docs/useCases/network
**** Total Files: 0
**** Total Directories: 38
**** Total Hard Links (nlink>1): 0
**** Total Symlinks: 0
**** Total Locking Errors: 0
**** Total items: 38
**** Elapsed time: 00:00:01
**** Metadata‐Only Report: DONE at Fri Nov 13 01:28:38 2009 ****
Removing the Drain Rule
You can remove a rule to both disable it and delete its configuration. From
gbl-ns-vol mode, use the no form of the place-rule command to remove a
placement/drain rule. For example, the following command sequence
removes the drain rule, “drainSrvW08,” from the “medarcv~/rcrds” volume:
bstnA(gbl)# namespace medarcv volume /rcrds
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# no place‐rule drainSrvW08
bstnA(gbl‐ns‐vol[medarcv~/rcrds])# ...
CLI Maintenance Guide
10 - 17
Chapter 10
Troubleshooting Managed Volumes
Removing an Imported Share
You can remove a share from its managed volume without affecting service
to the volume’s clients. The remove-share migrate command migrates all of
the share’s files and master directories to another share or share farm in the
same volume. (A master directory is the first-imported (or only) instance of
a directory in the managed volume.)
Important
This is not recommended in a volume that supports snapshots. In those
volumes, you should drain the share first, wait until allretained snapshots
have “aged out,” and then run this command. For instructions on draining
all files from a share, recall Draining One or More Shares, on page 10-12,
above.
Before you remove the share, you must first verify that it is not referenced
by any policies or rules; look for the share name in the volume’s rules (use
the show policy namespace ... volume command, as shown in Focusing on
One Volume, on page 14-40 of the ARX® CLI Storage-Management Guide).
Also, the share must be online in the namespace: use show namespace
status to confirm this (see Monitoring the Import, on page 9-56 of the same
manual).
To retain copies of all migrated files, you have the option to use migrate
retain-files in the share before you remove it (recall Retaining Copies of
Files on the Share (optional), on page 10-14).
From priv-exec mode, use remove-share migrate to remove the share:
remove‐share migrate namespace volume share destination [close‐file [exclude fileset]] [async]
where:
namespace (1-30 characters),
volume (1-1024 characters), and
share (1-64 characters) all identify the share to remove, and
destination (1-64 characters) is the destination share or share farm.
This command migrates all of the share’s files and master
directories to the destination. This must be a share or share farm in
the same volume.
close-file (optional) causes the operation to close all files open by
CIFS clients in order to migrate them. If you omit this option, files
opened by CIFS clients cannot migrate off of the selected share.
This would leave files stranded on the share and cause the share
removal to fail.
exclude fileset (optional if you choose close-file, 1-64 characters)
is a fileset to exclude from automatic closure. If a file in this fileset
is open through CIFS, the rule places it on a retry queue instead of
10 - 18
Removing an Imported Share
automatically closing it. If such a file remains open for the duration
of the share removal, it never migrates off of the share and the
share-removal fails.
async (optional if you specify a destination) makes this command
return immediately, rather than waiting for the share removal to
finish.
The CLI prompts you with a warning before removing the share; enter yes
to proceed. The CLI blocks as the volume migrates the files and directories
off of the share, then prints a message indicating the success of the share
removal.
Note
If the removal is interrupted by a reboot and/or failover, it may be
incomplete after the switch(es) finish booting. You can re-run the command
to finish removing the share.
For example, the following command removes the ‘/acct~it5’ share from the
‘wwmed’ namespace, and migrates its files and master directories to the
‘fm1’ share farm.
bstnA(gbl)# end
bstnA# remove‐share migrate wwmed /acct it5 fm1
WARNING !! Share 'it5' will be removed from volume '/acct' in namespace 'wwmed' after migrating files to 'fm1'
Proceed? [yes/no] yes
bstnA# ...
Removing the Empty Directory Tree
When you remove a share from a namespace, it leaves its empty directory
tree on the share's back-end filer. After removing the share, you can access
the filer directly and remove the empty directory tree.
Extra Processing in a Multi-Protocol Volume
If the share is in a multi-protocol (NFS and CIFS) volume, the volume may
require additional processing for the migration. The extra processing guards
against a file or directory on the source share colliding with a filer-generated
name (FGN) at the destination. The volume does not record filer-side FGNs
in its metadata; it deduces when collisions are possible and then uses probes
to check for them.
Migrating NFS-Only Directories
Any file or directory with a back-end FGN is labeled NFS-only; CIFS
clients cannot access it through the volume, and the ARX software cannot
reliably find its CIFS-side FGN. The CIFS attributes for NFS-only files and
directories are therefore inaccessible to the ARX. This is especially
CLI Maintenance Guide
10 - 19
Chapter 10
Troubleshooting Managed Volumes
important for directories. If the volume cannot find a directory’s CIFS
attributes, it cannot make a precise duplicate of the directory. The
migrations for NFS-only directories therefore fail.
You can work around this in one of two ways: rename all NFS-only
directories so that they are accessible through CIFS, or remove an
attribute-consistency check at the destination share. The first option is
recommended, but not always possible. The second option causes an
undesirable side-effect; it reduces any unknown CIFS attributes to zero. To
remove the attribute-consistency check, go to gbl-ns-vol-shr mode for the
destination share and use the no strict-attribute-consistency command:
no strict‐attribute‐consistency
Important
This removes the CIFS attributes from NFS-only directories that migrate to
the share. We recommend that you use this feature only under the guidance
of F5 personnel.
For example, the following command sequence turns off strict-attribute
consistency in the ‘shr1-next’ share:
bstnA(gbl)# namespace insur
bstnA(gbl‐ns[insur])# volume /claims
bstnA(gbl‐ns‐vol[insur~/claims])# share shr1‐next
bstnA(gbl‐ns‐vol‐shr[insur~/claims~shr1‐next])# no strict‐attribute‐consistency
bstnA(gbl‐ns‐vol‐shr[insur~/claims~shr1‐next])# ...
Forcing Strict-Attribute Consistency
Strict-attribute consistency is recommended for most situations. Typically,
you restore this consistency check after the migration is finished. From
gbl-ns-vol-shr mode, use strict-attribute-consistency to enable the
consistency checks:
strict‐attribute‐consistency
For example, the following command sequence re-instates strict-attribute
consistency in the ‘shr1-next’ share:
bstnA(gbl)# namespace insur
bstnA(gbl‐ns[insur])# volume /claims
bstnA(gbl‐ns‐vol[insur~/claims])# share shr1‐next
bstnA(gbl‐ns‐vol‐shr[insur~/claims~shr1‐next])# strict‐attribute‐consistency
bstnA(gbl‐ns‐vol‐shr[insur~/claims~shr1‐next])# ...
Finding Reports About the Share Removal
Each remove-share operation creates two reports as it runs:
• drain_share_rule_for_share_share-name_time.rpt, and
• remove.job-id.share-name.share-id.rpt
10 - 20
Removing an Imported Share
These describe two of the phases in removing a share. The first phase uses a
placement rule to drain all files and directories from the share (see Draining
One or More Shares, on page 10-12). The second phase removes the share
from the namespace.
Use show reports type Plc to list all file-placement (and drain-share) reports.
To list all of the remove-share reports, use show reports type Rm. For
example, this shows the two reports (highlighted in bold text) from
removing the it5 share:
bstnA# show reports type Plc
reports
Codes: Plc=Place Rule
daily_archive_201002240100.rpt Feb 24 01:00 2.3 kB Plc DONE: 0 in 00:00:10
daily_archive_201002240156.rpt Feb 24 01:56 2.3 kB Plc DONE: 0 in 00:00:11
daily_archive_201002240205.rpt Feb 24 02:05 2.3 kB Plc DONE: 163 in 00:00:13
docsPlc_20100224005857.0.rpt Feb 24 00:58 2.1 kB Plc FAILED: 0 in 00:00:01
docsPlc_20100224005857.rpt Feb 24 00:58 2.0 kB Plc FAILED: 0 in 00:00:01
drain_share_rule_for_share_it5_201002240213.rpt Feb 24 02:21 2.3 kB Plc DONE: 44 in 00:07:34
drain_share_rule_for_share_shr1‐old_201002240213.rpt Feb 24 02:13 2.3 kB Plc DONE: 159 in 00:00:31
mvDats_201002240240.rpt Feb 24 02:41 2.3 kB Plc DONE: 0 in 00:00:10
bstnA# show reports type Rm
reports
Codes: Rm=Remove
remove.19.shr1‐old.26.rpt Feb 24 02:14 1.3 kB Rm DONE: 42 in 00:00:01
remove.23.it5.8.rpt Feb 24 02:21 1.3 kB Rm DONE: 942 in 00:00:01
bstnA# ...
Showing the Drain-Share Report
The drain-share report shows the number of files migrated off of the share.
Use the show reports command to show it. For example, this shows the
numbers of files migrated from the it5 share:
bstnA# show reports drain_share_rule_for_share_it5_201002240213.rpt
**** File Placement Report: Started at Wed Feb 24 02:13:27 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
Place Rule: drain_share_rule_for_share_it5
Configuration:
Namespace: wwmed
Volume Name: /acct
Source share: it5
Target share‐farm: fm1
Report: drain_share_rule_for_share_it5
Report Verbose: Disabled
Report Delete Empty: Disabled
Report Errors Only: Disabled
Migrate limit: 0
Volume Scan: Enabled
Inline Notifications: Enabled
CLI Maintenance Guide
10 - 21
Chapter 10
Troubleshooting Managed Volumes
Promote Directories: Enabled
Auto‐Close Files: Disabled
Tentative: No
State: Enabled
Scan Statistics:
Scan Started: Wed Feb 24 02:13:43 2010
Scan Completed: Wed Feb 24 02:21:01 2010
Elapsed Time: 00:07:18
Number of Times Paused: 0
Total Time Paused: 00:00:00
Number of Times Stopped by Low Space: 0
Time Waiting for Free Space: 00:00:00
Files Scanned: 6
Directories Scanned: 39
Files in Fileset: 6
Files Migrated: 6
Size of Files Migrated: 68 kB
Directories Promoted: 38
Failed Migrations: 0
Size of Failed Migrations: 0 B
Failed Directory Promotes: 0
Files Forced Closed: 0
Suppressed Error Messages: 0
Total processed: 44
Elapsed time: 00:07:34
**** File Placement Report: DONE at Wed Feb 24 02:21:01 2010 ****
bstnA# ...
Showing the Remove Report
The remove report shows the details of the share removal from the volume.
For example, this shows the removal of the it5 share:
bstnA# show reports remove.23.it5.8.rpt
**** Storage Remove Report: Started at Wed Feb 24 02:21:03 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: wwmed
**** Volume: /acct
**** Source Share: it5
**** Source IP: 192.168.25.24
**** Source Export: /lhome/it5
**** Relocate Share: bills
**** Relocate IP: 192.168.25.25
**** Relocate Export: /work1/accting
**** Options: remove‐file‐entries verbose
**** Legend:
**** !! = Error occurred during storage removal.
**** AR = Directory needs manual attribute recovery by user.
**** FF = Found file during remove without remove‐file‐entries setting.
**** RF = Removed file from metadata with remove‐file‐entries verbose setting.
Prepare Phase:
============================================================
10 - 22
Removing an Imported Share
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Prepare Start Time: Wed Feb 24 02:21:03 2010
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Number of Keys Evaluated: 471
Number of Directories Evaluated: 471
Number of Migrations Aborted: 0
Number of Directories Promoted: 0
Number of Directories Migrated: 0
Number of Directories Recovered: 0
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Prepare Stop Time: Wed Feb 24 02:21:03 2010
Prepare Elapsed Time: 00:00:00
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Commit Phase:
============================================================
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Commit Start Time: Wed Feb 24 02:21:03 2010
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Number of Directories Evaluated: 471
Number of Files Removed: 0
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Commit Stop Time: Wed Feb 24 02:21:03 2010
Commit Elapsed Time: 00:00:00
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
**** Elapsed time: 00:00:01
**** Storage Remove Report: DONE at Wed Feb 24 02:21:04 2010 ****
bstnA# ...
Removing the Share Asynchronously
By default, the CLI waits for the share removal to finish before allowing you
to enter any more commands. Add the async flag at the end of the command
to return to the CLI immediately after confirming the removal:
remove‐share migrate namespace volume share destination async
This produces a brief report that summarizes the results, in addition to the
more-extensive report described above. The CLI shows the name of the
report after you enter yes to proceed.
For example:
bstnA(gbl)# end
bstnA# remove‐share migrate wwmed /acct it5 fm1 async
WARNING !! Share 'it5' will be removed from volume '/acct' in namespace 'wwmed' after migrating files to 'fm1'
Proceed? [yes/no] yes
Scheduling report: removeShare.it5.rpt
bstnA# ...
CLI Maintenance Guide
10 - 23
Chapter 10
Troubleshooting Managed Volumes
Removing Shares Without File Migration
You can also remove a share without migrating its files. This may have an
impact on clients; any of the share’s files that are visible to them will appear
to vanish. This is typically reserved for share-import failures (described later
in the chapter), or situations where a major change has been announced to
the client base. As with the remove-share migrate command, this command
migrates the share’s master directories.
From priv-exec mode, use the remove-share nomigrate command to remove
a share from a namespace without migrating any of its files:
remove‐share nomigrate namespace volume share destination [async]
where all of the options are described above. The destination is
required for the share’s master directories, which must migrate before
the share is removed. In multi-protocol volumes, master directories with
NFS-only names cannot migrate to the destination share; resolve this as
discussed above, in Migrating NFS-Only Directories, on page 10-19.
The CLI prompts for confirmation; enter yes to continue. The back-end
share does not lose any of its files or directories when you use this
command. You can access the share directly when the share-removal
completes.
For example, the following command sequence removes the ‘/rcrds~oldrx’
share from the ‘medarcv’ namespace. All of the share’s master directories
migrate to the ‘rx’ share:
bstnA(gbl)# end
bstnA# remove‐share nomigrate medarcv /rcrds oldrx rx async
WARNING !! Share 'oldrx' will be removed from volume '/rcrds' in namespace 'medarcv' WITHOUT migrating files.
Proceed? [yes/no] yes
Scheduling report: removeShare.oldrx.rpt
bstnA# ...
Forcing the Share Removal for Offline Filers
A online-share removal requires a scan of the filer. The scan finds the file
attributes (such as ownership and access permissions) for all master
directories. In cases where the filer or back-end share is offline, this scan
fails and the share cannot be removed. To skip the scan and force the
removal, use the force option at the end of the remove-share nomigrate
command:
remove‐share nomigrate namespace volume share destination [async]
where the options are as described above.
Since the volume cannot scan the file attributes for the master directories, it
sets all file attributes to 0 (zero) for the relocated master directories. You
must manually correct these attributes by accessing the volume through its
virtual server’s VIP. To identify the directories that need correction, consult
10 - 24
Removing an Imported Share
the remove report (described above; see Showing the Remove Report, on
page 10-22). Each directory that requires attribute resets has an [AR] next to
it in the report.
The CLI prompts you with a warning before removing the share; enter yes
to proceed. The CLI blocks as the volume removes the share, then prints a
message indicating the success of the share removal.
For example, the following command sequence removes a share,
“ns~/~defunctShr:”
bstnA(gbl)# end
bstnA# remove‐share nomigrate ns / defunctShr rx async
WARNING !! Share 'defunctShr' will be removed from volume '/' in namespace 'ns' WITHOUT migrating files.
Proceed? [yes/no] yes
Scheduling report: removeShare.defunctShr.rpt
bstnA# ...
Canceling a Share Removal
Before the share removal begins, the volume scans the back-end filer. This
scan collects all attributes for all of the share’s master directories, to be
duplicated at the destination share. It is possible to cancel the share removal
during this scan, which takes longer than the other removal phases. From
priv-exec mode, use the cancel remove command to cancel a share removal:
cancel remove namespace ns volume vol‐path share share‐name
where:
ns (1-30 characters) identifies the namespace.
vol-path (1-1024 characters) is the share’s volume.
share-name (1-64 characters) is the share.
For example, the following command sequence stops the removal of the
“wwmed~/acct~expir” share:
bstnA(gbl)# end
bstnA# cancel remove namespace wwmed volume /acct share expir
Storage job cancelled successfully.
bstnA# ...
CLI Maintenance Guide
10 - 25
Chapter 10
Troubleshooting Managed Volumes
Removing An Offline Share
You can remove an offline, unreachable, or otherwise defunct back-end
share from a namespace by using the remove-share offline CLI command
in privileged-exec mode. Use this command only for a back-end share that is
unreachable on a metadata-based managed volume, not on a direct volume.
If the share is still reachable, use remove-share migrate or remove-share
nomigrate instead.
When executed, the command creates a report,
“remove.job-id.share-name.share-id.rpt.” Use show reports to view its
contents.
The remove-share offline command deletes all of the share’s files from the
volume’s metadata; from the client’s perspective, these files disappear.
Given that the back-end filer was unreachable to begin with, those files were
inaccessible to clients already. Before removing the share, resolve all
dependencies on the share. Use the show policy command to verify that no
policy rules reference the share.
The command syntax follows:
remove‐share offline namespace volume share dest [async]
where:
• namespace (1 - 30 characters) is the name of the namespace.
• volume (1 - 1024 characters) is the name of the volume.
• share (1 - 64 characters) is the name of the share.
• dest (1 - 64 characters) is the new destination share or share farm where
the original share’s master directories (if any) are to be migrated. A
master directory is the first-imported instance of a directory in the
managed volume. Use show global-config namespace for a list of
shares and share farms in the namespace.
• async (optional) makes this command return immediately, rather than
waiting for the share removal to finish.
10 - 26
Correcting Share-Import Errors
Correcting Share-Import Errors
After you enable a namespace volume, the volume reads all of its back-end
shares and imports all of their files and directories. If anything goes wrong
in any share, the failed share shows a Status of “Error” in the show
namespace status output, and one of the errors in Table 10.1 appears in the
more-verbose show namespace output. Use show namespace (not show
namespace status) to see the full error message.
Follow the suggestions in the table to find and fix the root cause of the error.
Once the error is corrected, retry the import.
The sections below the table describe various methods for either restarting
the import or removing the share.
Status Condition
Error: A directory was removed from the filer during import.
Description/Action
A directory was found during an early scan of the filer share, then later it
was missing. Either a client or client application must have accessed the
filer directly (that is, not through this managed volume) during the import.
This ARX cannot support unexpected changes to the back-end shares
during (or after) import.
After you correct the problem, use nsck ... rebuild volume to reimport all
shares in the volume.
Error: A filename/directory could not be mapped to the namespace character encoding.
One of the share’s directories has a name with Unicode characters that
are unsupported by the character-encoding nfs setting. CIFS file names
are Unicode and can contain any character, but NFS servers and clients
must each configure their character encoding for file names. The volume
cannot import a directory with any un-mappable characters in its name.
You can use the import rename-directories unmapped-unicode
command to allow the volume to rename such directories during import,
or you can rename them manually at the filer. Then restart the share
import: enter gbl-ns-vol-shr mode and re use the enable (gbl-ns-vol-shr)
command.
Error: a higher priority share failed to initialize import.
A share with a higher import priority has failed its import, so this share
cannot import. If any share import fails, the managed volume cannot
import any shares with lower import priorities. Find the import error for
the failed share(s), look for the error in this table, and take action as
directed. This error is resolved as soon as all higher-priority shares
successfully import.
Table 10.1 Share Status Conditions
CLI Maintenance Guide
10 - 27
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: Access denied by filer.
Description/Action
This indicates that the ARX does not have proper permissions to connect
to the back-end filer, or to perform some operation in the filer share.
For NFS exports, check your back-end filer configuration: the back-end
share should allow root access to all of the ARX’s proxy IP addresses.
Use the show exports command examine all permission settings at the
filer. Use the show ip proxy-addresses command to list all configured
proxy IP addresses.
For CIFS shares, the switch uses the namespace’s proxy user
(username and password). The proxy-user credentials must belong to
the Administrators group at every filer behind the namespace. Use the
probe exports command to check this. The proxy-user (gbl-ns) command
sets the proxy user credentials for a namespace.
This may also indicate that the ARX is examining a read-only directory,
such as the “~snapshot” directory in a NetApp filer. Such directories
should be ignored during import. The gbl-filer ignore-name command
identifies these types of directories.
After you find and fix the error, you can restart the share import: enter
gbl-ns-vol-shr mode for this share and re use the enable (gbl-ns-vol-shr)
command.
Error: Another share in the volume failed to import.
Error: Attempted to import subdirectory which is also a managed root
All shares in the volume must import successfully for the volume to come
online. Address the share that does not have this error, then restart this
share import: enter gbl-ns-vol-shr mode for this share and re use the
enable (gbl-ns-vol-shr) command.
This share is a parent to an already-imported share. Namespace shares
cannot overlap. Use the filer command to change the path or share
name.
After you correct the problem, use nsck ... rebuild volume to reimport all
shares in the volume.
Error: Attributes of the share root are inconsistent.
Error: Authentication error during import.
The share’s root directory has attributes (such as owner, group, and
permission settings) that are inconsistent with those of the
already-imported shares. You can access the back-end filer directly to
change these attributes, or you can use the import sync-attributes
command to allow the volume to change the attributes for you. Then
re-enable the share (enable (gbl-ns-vol-shr)) to restart its import.
The ARX does not have proper permissions to connect to the back-end
filer.
For NFS exports, check your back-end filer configuration: the back-end
share should allow root access to all of the ARX’s proxy IP addresses.
Use the show exports command examine all permission settings at the
filer. Use the show ip proxy-addresses command to list all configured
proxy IP addresses.
For CIFS shares, the switch uses the namespace’s proxy user
(username and password). The proxy-user credentials must belong to
the Administrators group at every filer behind the namespace. The
proxy-user (gbl-ns) command sets the proxy user credentials for a
namespace.
After you find and fix this issue, you can restart the share import: enter
gbl-ns-vol-shr mode for this share and re use the enable (gbl-ns-vol-shr)
command.
Table 10.1 Share Status Conditions (Continued)
10 - 28
Correcting Share-Import Errors
Status Condition
Error: Bad Export Path/Share Name
Error: CIFS ABE check failed.
Description/Action
The share cannot be found on the external filer. Use the filer command to
change the path or share name for this share, then re-enable the share
(enable (gbl-ns-vol-shr)) to retry the import.
(CIFS) The volume supports cifs access-based-enum (ABE), and
attempted to replicate ABE settings between its back-end shares. This
replication process failed. The same process also checks for CIFS
subshares (filer-subshares), so you can use sync subshares
from-namespace ... tentative to get a full report on this issue.
This often occurs because the ARX does not have proper permissions to
check for ABE support on this back-end share. The ARX uses the
namespace’s proxy user (username and password) as its identity when it
checks for ABE support. The proxy-user credentials must belong to the
Administrators group at this back-end filer. You can use the proxy-user
(gbl-ns) command to choose new proxy user credentials for the
namespace.
After you find and fix this issue, use nsck ... rebuild volume to reimport all
shares in the volume.
Error: CIFS error during import scan.
(CIFS) This is a CIFS error that is not an access or network error, but
prevented the import. The syslog shows the specific error. Use show logs
syslog to read the syslog, or grep string logs syslog to search for a
specific string in the syslog.
After you correct the error, re-enable the share (enable (gbl-ns-vol-shr))
to retry the import.
Error: CIFS filer connection limit reached.
Error: CIFS operation attempted on a symbolic link.
(CIFS) The back-end filer imposes a limit on CIFS connections, and the
import requires more connections than the filer allows. Correct this at the
back-end filer and then re-enable the share to retry the import.
(multi-protocol) The volume software encountered an NFS symbolic link
on this back-end share, and the volume has cifs deny-symlinks enabled.
You can resolve this issue by using the no cifs deny-symlinks command
to allow the volume software to follow these links. Alternatively, you can
remove all NFS symbolic links from the back-end share.
After you fix this issue, use nsck ... rebuild volume to reimport all shares
in the volume.
Error: CIFS operation failed with an error during import.
(CIFS) The back-end filer returned an unexpected CIFS error during
import. The syslog shows the specific error. Use show logs syslog to
read the syslog, or grep string logs syslog to search for a specific string
in the syslog. You may need to escalate to F5 Support.
After you correct the error, re-enable the share (enable (gbl-ns-vol-shr))
to retry the import.
Error: CIFS operation failed with an error indicating a filer fault.
(CIFS) The filer returned an unexpected error during the import, and the
error indicates a problem at the filer itself. The syslog shows the specific
error. (Use show logs syslog to read the syslog, or grep string logs
syslog to search for a specific string in the syslog.) Check the filer itself
and correct the problem there.
After you correct the error, re-enable the share (enable (gbl-ns-vol-shr))
to retry the import.
Table 10.1 Share Status Conditions (Continued)
CLI Maintenance Guide
10 - 29
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: CIFS operation returned an error indicating an unsupported option.
Description/Action
(CIFS) The back-end share returned an error indicating that it does not
support a CIFS option that the ARX requires. Consult the F5 Data
Solutions Compatibility Matrix (included in this doc set) to confirm that
the filer has been qualified for use behind the ARX. If the share cannot
possibly support CIFS behind an ARX, you can use no share to remove
the share from the volume.
After you fix this issue, use nsck ... rebuild volume to reimport all shares
in the volume.
Error: CIFS proxy‐user not privileged.
(CIFS) The namespace software attempted to write a test file to the
share and failed. Go to the filer and check permissions for the
namespace’s proxy-user (gbl-ns); the proxy user must be part of the
Backup Operators and/or Administrators group on the filer.
After you correct the error, re-enable the share (enable (gbl-ns-vol-shr))
to retry the import.
Error: CIFS subshare check failed.
(CIFS) The volume supports filer-subshares and/or cifs
access-based-enum (ABE), and attempted to replicate subshares,
subshare ACLs, and/or ABE settings between its back-end shares. This
replication process, also known as subshare synchronization, failed. As a
result, any front-end export of the failed subshare will be degraded. The
output of show cifs-service fqdn shows all of the degraded subshares in
a given fqdn service.
Use sync subshares from-namespace ... tentative to get a full report on
this issue. To repair it, use the sync subshares from-namespace or sync
subshares from-service command without the tentative option.
Error: Cannot find credentials for connection to filer.
(CIFS) Proxy user credentials have not been properly configured for the
CIFS share. These credentials must be a username and password from
the Administrators group.
Use the proxy-user command to add or edit these credentials, and use
the proxy-user (gbl-ns) command to apply them to a namespace.
After you correct the error, re-enable the share (enable (gbl-ns-vol-shr))
to retry the import.
Error: Collision rename failed due to open file on share.
(CIFS) The share had a file that collided with an already-imported file,
and the volume failed to rename it because a CIFS application has it
open and locked.
You can use show cifs-service open-files to find the open file, close cifs
file to close it, and then retry the share import (with enable
(gbl-ns-vol-shr)).
Table 10.1 Share Status Conditions (Continued)
10 - 30
Correcting Share-Import Errors
Status Condition
Error: Could not update attributes on a file/directory during import.
Description/Action
Failure to update file attributes can be caused by loss of connectivity
during the import. Use the show exports command and/or ping to check
the connection to the filer.
For CIFS shares, this may indicate permissions problems. Proxy-user
credentials may not have been properly configured for the CIFS share.
These credentials must be a username and password from the
Administrators group.
Special, immutable directories can also cause this. The .snapshot
directory (on some systems) is an example of an immutable directory,
though .snapshot directories are properly ignored by the import software.
To ignore other directories on this filer, use the gbl-ext-filer ignore-name
command.
After you correct the error, re-enable the share (enable (gbl-ns-vol-shr))
to retry the import.
Error: Detected collisions/inconsistencies during no modify import.
Two or more of the volume’s shares had common file names that either
collided or had NFS/CIFS naming inconsistencies, and this volume
disallows import if it encounters either of these problems. As an example
of a collision, suppose share A and share B had the same file in the
same path, \docs\index.htm: these files would collide. A naming
inconsistency can only occur for a directory in a multi-protocol (NFS and
CIFS) namespace; the CIFS-side directory name has unicode characters
that are inexpressible on the NFS-side (see the documentation for the
character-encoding nfs command). The volume must be allowed to
modify the directory (or one of the colliding files) for the import to
succeed: the directory or file must be renamed.
All duplicate files and naming inconsistencies are recorded in the import
reports for each share. These reports are named
“import.job-id.share-name.share-id.rpt.” Use show reports to list all
import reports and read their contents.
Using the import report for each share, resolve all file collisions and
naming inconsistencies before re-importing. Go to the filers and rename
the files, move them, and/or resolve that certain file renames are
acceptable. Once the issues are cleared, use the gbl-ns-vol
reimport-modify and modify commands to allow modification (renames)
on import. (If any other shares are still importing, you must wait for their
imports to finish before you can use the modify command.) To rename
inconsistent NFS/CIFS directories, use the import rename-directories
unmapped-unicode command, too.
After you correct the problem, use nsck ... rebuild volume to reimport all
shares in the volume.
Error: Device Offline
The share’s back-end filer went offline for an extended time in the middle
of the import. You can remove the share from the volume, or resolve the
issue at the filer and retry the import.
To retry the import, you can use the enable (gbl-ns-vol-shr) command on
this share.
Error: DFS links found on share during import.
Managed volumes do not support Distributed File System (DFS) links. To
find all of the DFS links on all of a volume’s shares, you can import the
share(s) with no modify.
Remove all DFS links from the back-end share. Then use the enable
(gbl-ns-vol-shr) command to retry the import.
Table 10.1 Share Status Conditions (Continued)
CLI Maintenance Guide
10 - 31
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: Directory attribute collision detected during import.
Description/Action
A directory on this share has the same name and path as a directory on
another share, but the attributes are different. (Directory attributes are
permission settings for various users and groups, along with various
other flags.) For example, suppose share A had a \docs\img directory
and share B had a directory with the same name but different write
permissions for the “Everyone” group.
To allow the volume to modify directory attributes on import, you can use
modify on the volume and import sync-attributes on the share. (If any
other shares are still importing, you must wait for their imports to finish
before you can use the modify command.) Then use the enable
(gbl-ns-vol-shr) command to retry the import.
Error: Directory collision; Unable to guarantee strict‐attribute‐consistency.
(multi-protocol) A directory on this share has the same name and path as
a directory on an already-imported share, but some of the CIFS attributes
are obscured for at least one of them. Obscured CIFS attributes, due to
filer-generated names for the directories, are common on a multi-protocol
filer. The volume requires that all attributes (for CIFS and NFS) be
synchronized for duplicate directories, and that is impossible under the
circumstances.
This can only occur for NFS-only directories, with names that are illegal
in CIFS. If possible, change the directory name(s) so that they are
accessible from CIFS. As an alternative, you can use no
strict-attribute-consistency to remove the requirement for strict-attribute
consistency; this reduces all undiscovered CIFS attributes to zero. Once
the volume has stopped importing any shares, you can do this for all
shares in the volume. Then restart this share import with the enable
(gbl-ns-vol-shr) command.
Error: Directory name collision detected during import.
A directory on this share has the same name and path as a file on an
already-imported share. For example, share B has a directory named
/var/log but share A was already imported with a file named /var/log.
To allow the volume to correct this by changing the directory name on
import, you can use modify on the volume and import rename-directories
on the share. Alternatively, you can directly access the filer(s) and
correct the problem there. Retry this share import (with enable
(gbl-ns-vol-shr)) after you address the issue.
Table 10.1 Share Status Conditions (Continued)
10 - 32
Correcting Share-Import Errors
Status Condition
Error: Dynamic Import operation failed due to a collision.
Description/Action
Two or more of the volume’s shares had common file/directory names
that somehow collided, causing one of the shares to fail its import. The
following collisions can cause this failure:
•
A file in share A has the same name and path as a file in share B.
•
A directory in share A has the same name and path as a file in share
B.
•
A directory in share A has the same name and path as a directory in
share B, and the directories have different attributes (such as
permissions). If they had the same attributes, they would not collide.
•
A file or directory in share A has a CIFS case collision with a file or
directory on share B, and the volume is set for no cifs case-sensitive.
For example, “myDir/MYFILE.doc” on share A could collide with
“myDir/myFile.doc” on share B.
All duplicate files and naming inconsistencies are recorded in the import
reports for the share. These reports are named
“import.job-id.share-name.share-id.rpt.” Use show reports type Imp to list
all import reports, and use show reports report-name to read a report.
Using the import report for this share, resolve all file collisions and
naming inconsistencies before re-importing. Go to the filers and rename
the files, move them, and/or resolve that certain file renames are
acceptable. You can also use some share-import options to have the
volume automatically rename files, rename directories, or reset directory
attributes in this share during import (import rename-files, import
rename-directories, or import sync-attributes). If you use any
share-import options, use the gbl-ns-vol reimport-modify and modify
commands to allow modification (renames) on import.
Then re-import the share with the enable (gbl-ns-vol-shr) command.
Error: Dynamic Import operation failed.
Error: Dynamic Import operation timed out.
Error: Encountered file(s) with more than 1024 hard links during import.
The share import failed for an undetermined reason. Run the collect
diag-info CLI command to collect diagnostic information, then contact F5
Support.
An internal import operation timed out, possibly due to a filer-connectivity
issue. Use the show exports command and/or ping to troubleshoot the
connection to the filer.
The managed volume software supports a maximum of 1024 hard links
per file. One or more files on this back-end share exceed this limit. These
files are recorded in the share’s import report, named
“import.job-id.share-name.share-id.rpt.” Use show reports type Imp to list
all import reports, and use show reports report-name to read a particular
report. Then access the filer directly to reduce the number of hard links
for all of these files.
After you correct the problem, use nsck ... rebuild volume to reimport all
shares in the volume.
Table 10.1 Share Status Conditions (Continued)
CLI Maintenance Guide
10 - 33
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: Export In Use By Another Switch
Description/Action
The filer share contains a hidden directory, .acopia, written by a different
ARX. Two ARXes cannot import the same share. If the share is not
imported by another switch anymore, remove the directory manually.
If this happens to all shares after a switch replacement, the old switch’s
UUID was not properly applied to the replacement switch. Consult the
appropriate Hardware Installation manual for switch-replacement
instructions.
After you correct the problem, use nsck ... rebuild volume to reimport all
shares in the volume.
Error: Export is read‐only, cannot import.
Check the share configuration at the filer: the ARX requires read/write
access throughout the share’s directory tree. Use the show exports
command to examine all permission settings at the filer.
Use the following guidelines for permissions problems:
•
For NFS exports, check your back-end filer configuration: the
back-end share should allow root access to all of the ARX’s proxy IP
addresses. Use the show ip proxy-addresses command to list all
configured proxy IP addresses.
•
For CIFS shares, the switch uses the namespace’s proxy user as its
identity. The proxy user, created by the proxy-user command, must
belong to the Administrators group. The proxy-user (gbl-ns)
command sets the proxy user for a namespace.
Once the permissions issue is resolved, you can re-import the share with
the enable (gbl-ns-vol-shr) command.
Error: Failed import initialization due to filer full condition.
The back-end share is full, so the ARX volume could not create the
.acopia directory and/or write some small files to mark the share. Go to
the filer and clear out some disk space before you retry the import.
Once some space is free, you can use the enable (gbl-ns-vol-shr)
command to restart the share import.
Error: Failed import initialization due to permissions or access error.
This indicates permissions problems at the back-end filer. Use the show
exports command to examine all permission settings at the filer.
Use the following guidelines for permissions problems:
•
For NFS exports, check your back-end filer configuration: the
back-end share should allow root access to all of the ARX’s proxy IP
addresses. Use the show ip proxy-addresses command to list all
configured proxy IP addresses.
•
For CIFS shares, the switch uses the namespace’s proxy user as its
identity. The proxy user, created by the proxy-user command, must
belong to the Administrators group. The proxy-user (gbl-ns)
command sets the proxy user for a namespace.
Once the permissions issue is resolved, you can re-import the share with
the enable (gbl-ns-vol-shr) command.
Error: Failed to Contact Filer.
The back-end device could not be located with the IP address configured
for the filer. From gbl-ext-filer mode, use the ip address command to
reset the filer’s address. Use the show exports command, expect
traceroute, and/or ping to check the connection to the filer.
After the filer connection is re-established, you can use the enable
(gbl-ns-vol-shr) command to restart the share import.
Table 10.1 Share Status Conditions (Continued)
10 - 34
Correcting Share-Import Errors
Status Condition
Error: Failed to contact filer for attribute lookup.
Error: Failed to contact portmap service during import scan.
Error: Failed to create a file/directory on filer.
Description/Action
(NFS) These errors indicate an NFS-server problem at the filer. Once the
filer’s NFS service is restored, you can use the enable (gbl-ns-vol-shr)
command to restart the share import.
This may indicate a full disk on the back-end filer or permissions
problems. Use the show exports command to examine all permission
settings at the filer.
Use the following guidelines for permissions problems:
•
For NFS exports, check your back-end filer configuration: the
back-end share should allow root access to all of the ARX’s proxy IP
addresses. Use the show ip proxy-addresses command to list all
configured proxy IP addresses.
•
For CIFS shares, the switch uses the namespace’s proxy user as its
identity. The proxy user, created by the proxy-user command, must
belong to the Administrators group. The proxy-user (gbl-ns)
command sets the proxy user for a namespace.
Once the permissions issue or space issue is resolved, you can re-import
the share with the enable (gbl-ns-vol-shr) command.
Error: Failed to create directory collision due to open CIFS file in path.
(multi-protocol) A directory on this back-end share has a case collision
with an already-imported directory, and a CIFS client has a file open in
the already-imported directory. For example, suppose the volume
imports /vol/mydir from one share, a client connects and opens a file in
that share (/vol/mydir/myfile.exe), and then the volume attempts to import
a second share with /vol/MYDIR. The volume must mark the first share
as “NFS-only” for the import to proceed, but cannot as long as the client
holds “myfile.exe” open. The second share therefore fails its import.
You can use show cifs-service open-files to find the open file, close cifs
file to close it, and then retry the share import (with the enable
(gbl-ns-vol-shr) command).
Error: Failed to find valid mount version during import scan.
Error: Failed to mount filer during import scan.
(NFS) These errors indicate an NFS-server problem at the filer. Once the
filer’s NFS service is fully restored, you can use the enable
(gbl-ns-vol-shr) command to restart the share import.
Error: Failed to open NFS connection to filer during import scan.
Error: Failed to resolve IP address for filer.
The back-end device could not be located with the filer name or IP
address configured for the filer. From gbl-ext-filer mode, use the ip
address command to reset the filer’s address.
Use the show exports command and/or ping to troubleshoot the
connection to the filer. After the filer connection is re-established, you
can use the enable (gbl-ns-vol-shr) command to restart the share import.
Error: Failed to retrieve Kerberos information.
(CIFS) The namespace supports Kerberos authentication (see cifs
authentication), but the namespace software is unable to confirm that the
share is configured to support Kerberos, too.
Check the connection to the back-end filer with show exports and/or
ping. Restart the import (with enable (gbl-ns-vol-shr)) after you correct
the problem.
Table 10.1 Share Status Conditions (Continued)
CLI Maintenance Guide
10 - 35
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: Failed to take pathlock due to internal operation in progress.
Error: Failed to unmount filer during import scan.
Error: File collision detected during import.
Description/Action
The share import failed due to an internal-software conflict, possibly due
to a timing issue or a brief filer-connectivity issue. Retry the import by
using the enable (gbl-ns-vol-shr) command on this share. If this error
returns, contact F5 Support.
(NFS) Persistent errors from a back-end share caused the mount to fail.
Check the NFS service at the back-end filer. Once the filer’s NFS service
is fully restored, you can use the enable (gbl-ns-vol-shr) command to
restart the share import.
A file on this share has the same name and path as a file on an
already-imported share. To fix this, you can manually go to the filer and
rename the file, or you can set the modify flag on this volume. By setting
the modify flag, you allow the volume to rename the file on import. (If any
other shares are still importing, you must wait for their imports to finish
before you can use the modify command.) You must also have the
default settings for import rename-files and import rename-directories on
this share.
Then restart the import with the enable (gbl-ns-vol-shr) command.
Error: File exists in CIFS, but not in NFS.
(multi-protocol) The share is configured for both NFS and CIFS, but a
directory that is visible in the back-end-CIFS share is not found in the
NFS export. The filer probably has two different names for the directory:
one for CIFS clients and one for NFS clients.
Check the directory at the back-end share, and rename it so that both
versions have the same name. Alternatively, you can set the modify flag
on this volume. By setting the modify flag, you allow the volume to
rename the directory on import. (If any other shares are still importing,
you must wait for their imports to finish before you can use the modify
command.)
You may also need to set import rename-directories unmapped-unicode
for this share; this allows the volume to rename directories whose CIFS
names do not map to the character encoding for NFS. Then restart the
import with the enable (gbl-ns-vol-shr) command.
Error: filename collision.
A file on this share has the same name and path as a file on an
already-imported share. To fix this, you can manually go to the filer and
rename the file, or you can set the modify flag on this volume. By setting
the modify flag, you allow the volume to rename the file on import. (If any
other shares are still importing, you must wait for their imports to finish
before you can use the modify command.) You must also have the
default settings for import rename-files and import rename-directories on
this share.
Then retry the import.
Error: Filer does not have enough free space to perform import.
(NFS) The ARX creates a temporary database on each share during the
import process: there is not enough room on this share to create the
database. The database requires at least 100 MegaBytes of free space.
Clear some free space at the filer share, then restart the import with the
enable (gbl-ns-vol-shr) command.
Table 10.1 Share Status Conditions (Continued)
10 - 36
Correcting Share-Import Errors
Status Condition
Error: Filer does not provide an NFS filehandle for a file in its directory listing.
Description/Action
(multi-protocol) The filer provided a file name in an NFS READDIR call,
but did not translate that file name into a filehandle in a subsequent
LOOKUP call. Some multi-protocol filers behave this way when a CIFS
file name has characters that are not supported by NFS; the filer returns
the UTF-8 version of the file name for the READDIR call, which it later
rejects in a subsequent LOOKUP call. The ARX can see the file in the
directory listing, but cannot get access to the file itself.
Rename the file at the filer share, then use nsck ... rebuild volume to
reimport all shares in the volume.
Error: Filer does not support specified protocols.
The protocol(s) configured for the back-end share are not actually
supported at the filer. Use the show exports command to check the
protocols supported by the filer. Use the show global-config namespace
command to view the required protocols for the namespace. The share
must support all of the namespace’s protocols.
You can remove the share from the volume (with no share), or you can
add protocol support at the back-end filer. If you add the protocol support
to the filer, you can then restart the share import with the enable
(gbl-ns-vol-shr) command.
Error: Filer error during import.
Error: Filer generated name collision is not supported by filer.
This may indicate a disk failure at the external filer. Correct the filer issue
and retry the import (with the enable (gbl-ns-vol-shr) command).
(multi-protocol) The share contains an entry whose filer-generated name
(FGN) matches a real name in an already-imported share, or whose real
name conflicts with an already-imported FGN. The volume is backed by
a mix of Hitachi HNAS (BlueArc) filers and filers from other vendors, and
this naming conflict is not supported for this vendor combination.
The import report shows the name of the conflicting file or directory. The
name appears with an “FC” notation. The report is named
“import.job-id.share-name.share-id.rpt.” Use show reports to list all
import reports and read their contents.
Using the import report, resolve all of these name collisions before
re-importing. Go to the filer to rename the files and/or directories. Then
use enable (gbl-ns-vol-shr) to re-import the share.
Error: Filer operation returned an unexpected error, see logs for more information.
The back-end filer behind this share returned an error that the ARX does
not recognize. You can use the show logs syslog command to view the
system log and learn more about the circumstances around the failure.
We recommend that you contact F5 Support if you see this import error.
You may be requested to run the collect command, which assembles
diagnostic information for F5 Engineering.
After the issue is resolved, use nsck ... rebuild volume to reimport all
shares in the volume.
Error: Filer returned invalid link count for a file.
The import failed because the back-end filer returned a link count of zero
or a negative number for a file, which is invalid. A file’s link count should
be one or more. The ARX syslog contains the file with the invalid link
count; use grep “link count” logs syslog to find the path. Use this path to
help diagnose and correct the filer issue. Then use the enable
(gbl-ns-vol-shr) command to retry the import.
Table 10.1 Share Status Conditions (Continued)
CLI Maintenance Guide
10 - 37
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: Hard Links Inconsistent
Description/Action
(NFS) One or more files in the exported directory have hard links from
outside the directory. That is, the switch tried to import a hard link to file X
but detected that there was at least one more hard link to file X in some
other directory, not included in the NFS export.
Remove the hard links from the external directories and retry the share
import.
Error: Hard Links Not Supported
Error: I/O error encountered talking to filer.
Error: Import database I/O failure.
(CIFS) Hard-links exist in a CIFS share (not supported in CIFS by the
ARX).
Use the show exports command and/or ping to check the connection to
the filer. Restart the import (with enable (gbl-ns-vol-shr)) after the
connection is restored.
(NFS) The ARX creates a temporary database during the import process.
The database was deleted while the import was underway. This may
indicate that other clients are bypassing the ARX to access the share,
which is an unsupported configuration.
You can restart the share import with the enable (gbl-ns-vol-shr)
command.
Error: Insufficient files reserved for the volume.
Error: Insufficient free space to store metadata.
This share contains more files than the volume can hold. Use the auto
reserve files command to automatically increase the number of files that
this volume can hold as the volume grows. If you prefer to manually set
the maximum files for the volume, use reserve files to manually increase
the maximum. Then restart the share import with the enable
(gbl-ns-vol-shr) command.
A volume’s metadata share requires gigabytes of free space; the one
chosen for this volume has less than one-half gigabyte. Choose a
metadata share with more free space: use the metadata share command
to configure a new metadata share.
After you choose another metadata share, or clear up several gigabytes
of free space on the current metadata share, you can use the enable
(gbl-ns-vol-shr) command to restart the import.
Error: Internal IPC communications failure during import.
Error: Internal thread error during import.
These errors each indicate an internal software problem. Run the collect
diag-info CLI command to collect diagnostic information, then contact F5
Support.
Once the issue is understood, you can restart the share import with the
enable (gbl-ns-vol-shr) command.
Table 10.1 Share Status Conditions (Continued)
10 - 38
Correcting Share-Import Errors
Status Condition
Error: Maximum number of namehash collisions for a filename reached in a directory.
Description/Action
A directory in this share has too many entries (files and/or subdirectories)
whose names differ only in case (for example, “thisFile.txt,” “THISfile.txt,”
“thisFILE.txt,” and so on). The limit on case collisions for a single entry
name is over 16,000. A client tried to create a new entry that would
exceed the limit for a particular entry name, and the volume blocked the
action with an “access denied” error.
You can resolve this issue by accessing the volume as a client and
moving as many of the file entries as possible. Create a new directory to
hold many of them, or rename them to a non-matching name. For
example, you could change the earlier examples to “thatFile.txt,”
“THATfile.txt,” and so on to stop them from making a case-insensitive
match with “thisfile.txt.”
The specific directory and file name appears in a syslog message
labeled “ERROR_MAX_HASH_COLLISIONS.” Use grep
ERROR_MAX_HASH_COLLISIONS logs syslog to search for this error
in the syslog.
Note that the colliding names are usually case collisions, but not always.
The collision occurs after a mathematical conversion of the file names,
called a hash.
After you clear enough colliding files from the directory, you can restart
the share import with the enable (gbl-ns-vol-shr) command.
Error: Maximum Path Length Exceeded
A path to one of the files exceeds the maximum, 1024 characters. You
must shorten the path(s) to import this share.
Once all of the share’s paths are below 1024 characters, you can restart
the share import with the enable (gbl-ns-vol-shr) command.
Error: Metadata database I/O failure.
There was a database I/O failure for the share. This may be caused by a
transient network error, or a filer problem. You can use the show exports
command to check the filer and connection for common problems.
Once the external problem is resolved, use nsck ... rebuild volume to
reimport all shares in the volume.
Error: Metadata filer configuration is invalid. Data written has been lost, corrupting the database.
This is not an import error: it typically occurs while the volume is
providing service. This condition disables the volume.
Some of this share’s metadata was lost at the volume’s metadata share.
This indicates that the metadata share did not synchronously write its
data; it wrote the data to a cache, told the ARX that the write succeeded,
and then lost the data between the cache and the disk. This is only
possible on an NFS export where either
•
the “async” option was set, or
•
“async” is the default for the NFS implementation (as with some
releases of Linux)
CIFS shares do not have this problem.
At the filer, set the “sync” option for the NFS export. We also recommend
that you specify the “no_wdelay” option.
Use nsck ... rebuild volume to re-initialize the metadata share and
reimport all shares in the volume.
Table 10.1 Share Status Conditions (Continued)
CLI Maintenance Guide
10 - 39
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: Metadata share unavailable during import.
Description/Action
The switch could not contact the metadata share. Use the show exports
command and/or ping to check the connection to the metadata share’s
filer. The show export command also verifies that the share is accessible
by root (for NFS shares) or the namespace’s proxy-user (gbl-ns) (for
CIFS shares).
After the connection is re-established, restart the share import with the
enable (gbl-ns-vol-shr) command.
Error: Mismatched NFS filename encoding.
Error: Mount to filer failed.
Error: Multi‐protocol share is split.
Error: Multi‐protocol user mapping error. (nfs read failure)
Error: Multi‐protocol user mapping error. (nfs remove failure)
Error: Multi‐protocol user mapping error. (nfs write failure)
Error: NFS connect failed.
Error: NFS error during import scan.
(multi-protocol) The NFS character-encoding setting for the namespace
does not match the character encoding supported at the filer. If this share
was imported, lost NFS files could result. Reset the namespace
character encoding (using the character-encoding nfs command) and
retry the import. You can use the enable (gbl-ns-vol-shr) command to
restart the share import.
(NFS) The switch was unable to NFS-mount the filer share. Check the
NFS service at the back-end filer.
(multi-protocol) The filer command specified an NFS export and a CIFS
share over two different directory trees. This is unsupported. Retry the
command with the correct share and export names, then retry the import
with enable (gbl-ns-vol-shr).
(multi-protocol) During import, the volume creates a test file through
CIFS and then attempts to read it through NFS. The volume was unable
to read the file as root. Check the NFS configuration at the back-end
share, correct the problem, and retry the import (enable (gbl-ns-vol-shr)).
(multi-protocol) During import, the volume creates a test file through
CIFS and then attempts to delete it through NFS. The volume could read
and write the file (as root), but was unable to remove it. This may indicate
a permissions problem in the top-level directory for the share. Check the
NFS configuration at the back-end share, correct the problem, and retry
the import (enable (gbl-ns-vol-shr)).
(multi-protocol) During import, the volume creates a test file through
CIFS and then attempts to write to it through NFS. The volume could
read the file, but was unable to write to it (as root). Check the NFS
configuration at the back-end share, correct the problem, and retry the
import (enable (gbl-ns-vol-shr)).
(NFS) Persistent NFS errors from a back-end share caused the import to
fail. Check the NFS service at the back-end filer.
After the filer’s NFS service is fully restored, you can restart the share
import with the enable (gbl-ns-vol-shr) command.
Error: NFS error occurred during import scan.
Error: NFS Error while scanning storage
Error: NFS Version Mismatch
(NFS) The back-end share does not support the NFS version(s)
configured for the external filer. Use the show exports command to check
the protocols supported by the filer. Use the filer command to change the
configured NFS version(s) for the share/export.
Table 10.1 Share Status Conditions (Continued)
10 - 40
Correcting Share-Import Errors
Status Condition
Error: NFSv2 error during import scan.
Error: NFSv3 error during import scan.
Error: Network communications failure during import scan.
Error: Network error or timeout during CIFS attributes check.
Error: Network error or timeout during CIFS privilege check.
Description/Action
(NFS) Persistent NFS errors from a back-end share caused the import to
fail. Check the NFS service at the back-end filer. After the filer’s NFS
service is fully restored, you can restart the share import with the enable
(gbl-ns-vol-shr) command.
Use the show exports command, expect traceroute, and/or ping to
troubleshoot the connection to the filer. After the filer connection is
re-established, you can restart the share import with the enable
(gbl-ns-vol-shr) command.
(CIFS) A connection error occurred in the middle of a CIFS-permissions
test. Use the show exports command, expect traceroute, and/or ping to
troubleshoot the connection to the filer. Once the connection is fully
restored, you can restart the share import with the enable (gbl-ns-vol-shr)
command.
Error: Network error or timeout during CIFS write check.
Error: No CIFS write access.
Error: No space left on share, or share unreachable
Error: No space on back‐end device.
Error: Operation aborted at user request.
Error: Permission Denied
The namespace’s proxy-user does not have adequate privileges to write
to this CIFS share, so the import failed. The proxy user must belong to
the Administrators group on this filer. You can choose new,
more-privileged credentials for your proxy user, or you can go to the filer
and add the current proxy user to a more-privileged group. The probe
exports command can verify that the new proxy-user credentials pass
this write test. Then restart the import with the enable (gbl-ns-vol-shr)
command.
The ARX got an error writing a database that is created as part of the
import process. This database is created on the filer share itself, so the
error indicates a problem with the filer.
Clear some free space at the filer share, then restart the import with the
enable (gbl-ns-vol-shr) command.
An administrator issued the cancel import command to stop this share
import. You can restart the import with the enable (gbl-ns-vol-shr)
command.
This indicates that the ARX did not have proper permissions to connect
to the back-end filer.
For NFS exports, check your back-end filer configuration: the back-end
share should allow access to all of the ARX’s proxy IP addresses. Use
the show exports command to check the filer’s permissions and
configuration. Use the show ip proxy-addresses command to list all
configured proxy IP addresses.
For CIFS shares, the switch uses the proxy user for the namespace; the
proxy-user (gbl-ns) command sets these credentials. The proxy user
must belong to the Administrators group.
After the permissions problem is corrected, you can restart the import
with the enable (gbl-ns-vol-shr) command.
Table 10.1 Share Status Conditions (Continued)
CLI Maintenance Guide
10 - 41
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: Protocol specific error, see logs for more information.
Description/Action
(CIFS) The back-end filer returned an unexpected CIFS error during
import. The syslog shows the specific error. Use show logs syslog to
read the syslog, or grep string logs syslog to search for a specific string
in the syslog. You may need to escalate to F5 Support.
After you correct the error, use nsck ... rebuild volume to reimport all
shares in the volume.
Error: Proxy User does not map to root user via NFS.
(multi-protocol) The proxy user is a Windows username and password
that the volume can use as its identity for share import and for policy
operations. In a multi-protocol (CIFS and NFS) namespace, the proxy
user on the Windows side must map to the root user on the UNIX side.
You can select a new proxy user for the namespace with the command.
If necessary, map the proxy user to root at the filer itself; the ARX Site
Planning Guide has instructions for creating this mapping on common
multi-protocol filers.
Error: Remove incomplete: found files on share.
An administrator failed to remove the share with no share because
client-visible files are still present on the share. Use the
remove-file-entries option to remove all of the file entries from the
volume; this produces a client-visible effect, so do this with caution.
Alternatively, you can use remove-share nomigrate.
Error: Root Squash is Enabled
(NFS) This indicates that the ARX did not have proper permissions to
create files at the back-end filer.
Check your back-end filer configuration: the back-end share should have
no-root-squash set for all of the ARX’s proxy IP addresses. (On some
filers, you accomplish this by mapping the anonymous user to UID 0
(zero).) Use the show exports command to check the filer’s permission
settings. Use the show ip proxy-addresses command to list all configured
proxy IP addresses.
Once the filer’s root-squash option is disabled, you can restart the import
with the enable (gbl-ns-vol-shr) command.
Error: RPC error during import scan.
(NFS) Persistent NFS errors from a back-end share caused the import to
fail. Check the NFS service at the back-end filer.
After the filer’s NFS service is fully restored, you can restart the share
import with the enable (gbl-ns-vol-shr) command.
Error: Share attributes incompatible with volume attributes.
(CIFS) The CIFS attributes set for the volume (with compressed-files,
named-streams, persistent-acls, sparse-files, and/or unicode-on-disk)
are not all supported at the back-end share. Use the show exports
command to check the supported CIFS attributes for the share.
You can remove the share from the volume (with no share) or disable the
conflicting CIFS attribute(s) in the managed volume. If you elect to keep
the share in the volume, use the enable (gbl-ns-vol-shr) command to
restart the share import.
Table 10.1 Share Status Conditions (Continued)
10 - 42
Correcting Share-Import Errors
Status Condition
Error: Share does not support Kerberos authentication.
Description/Action
(CIFS) The namespace supports Kerberos authentication (see cifs
authentication), but this share does not. The share must support
extended security negotiations for the import to succeed. Also, the ARX
needs the correct service-principal name (SPN) for the filer; you can use
show exports ... capabilities to verify that the ARX has discovered the
correct SPN for the filer, or you can use the spn command to set it
manually.
After you ensure that the filer support Kerberos and the ARX has the
filer’s SPN, you can restart the import (enable (gbl-ns-vol-shr)).
Alternatively, you can remove the share from the volume with no share.
Error: Share type does not match namespace supported protocols.
Each back-end share must support all of the namespace’s configured
protocols (any combination of NFSv2, NFSv3(/UDP), NFSv3/TCP, and
CIFS). Use the show global-config namespace command to view the
namespace’s protocols.
You can remove the share from the volume (with no share) or enable the
missing service(s) at the filer. If you elect to keep the share in the
volume, use the enable (gbl-ns-vol-shr) command to restart the share
import.
Error: Specified export is not a directory.
The export name is incorrect in the external-filer configuration. Use the
filer command to change the configured name for the share/export.
Error: Specified export is too long.
Error: Specified export not found on filer.
Error: Stat of a file/directory failed during storage init.
(NFS) The ARX was unable to access the attributes of a file or directory.
Check the NFS service at the back-end filer. To check the ARX’s
connectivity to the filer and perceived permissions at the filer, use show
exports.
You can restart the share import with enable (gbl-ns-vol-shr) after you
resolve the filer issue.
Error: Storage is already in use by this switch pair.
The share is already imported into another managed volume on this
switch (or its redundant peer). Evidently, the back-end share has at least
one alias and it was previously imported under another name. A share
can only be managed by one volume at a time, under a single name.
From gbl-ns-vol-shr mode in the CLI, use no filer to detach from the
back-end share. Then choose another back-end path with the filer
command, or use no share to remove the share from the volume.
To restart the import (with or without this share), use nsck ... rebuild
volume to reimport all shares in the volume.
Error: Storage remove failed because pending directory operations could not be flushed.
Someone attempted to remove a share (with no filer, no share,
remove-share migrate, remove-share nomigrate, or remove service), and
an internal error caused the removal to fail. Contact F5 Support if you
see this message.
Table 10.1 Share Status Conditions (Continued)
CLI Maintenance Guide
10 - 43
Chapter 10
Troubleshooting Managed Volumes
Status Condition
Error: Unable To Connect to CIFS Share.
Error: Unable to read file due to stale filehandle.
Description/Action
The connection to the back-end CIFS share failed due to possible
configuration errors or a broken connection to the back-end filer. Use the
show exports command, expect traceroute, and/or ping to troubleshoot
the connection to the filer. Once the connection is fully established, you
can restart the share import with the enable (gbl-ns-vol-shr) command.
(NFS) The filer provided a filehandle in response to an earlier NFS call,
and is now pronouncing it “stale.” This is inconsistent filer behavior; it
may indicate that NFS clients are bypassing the ARX to access the
share. Check the filer share and correct the problem there.
Once the filer issue is corrected, use nsck ... rebuild volume to reimport
all shares in the volume.
Error: Unexpected CIFS privilege check failure.
Error: Unexpected CIFS write check failure.
Error: Unresolvable case‐blind name collision.
A CIFS-permission test failed at the filer for an undetermined reason.
This may be a filer issue or a connectivity issue. Check the filer and the
connection, and retry the share import (with enable (gbl-ns-vol-shr)). If
this error stops the import a second time, run the collect diag-info CLI
command to collect diagnostic information and contact F5 Support.
(CIFS) A file on this share has the same name and path as a file on an
already-imported share, based on a case-blind comparison, and the
volume is configured with no cifs case-sensitive. That is, some of the
characters have differing cases, but the characters match (for example,
“index.htm” matches “index.HTM”). If the volume is not case-sensitive, it
cannot see the difference between the two names.
You have three options to address this error:
•
Manually go to the filer and rename the file.
•
Set the modify flag on this volume. By setting the modify flag, you
allow the volume to rename the file on import. You must wait for all
the volume’s shares to finish importing before you can use this
command.
•
Use cifs case-sensitive to make the volume case-sensitive.
Then retry the import with the enable (gbl-ns-vol-shr) command.
Import Interrupted
Internal Error (number)
Metadata Only
Offline: Volume Disabled
Offline: Volume Failed
An administrator stopped the import with the cancel import command.
You may be able to restart the import with no enable (gbl-ns-vol-shr) and
then enable. If the import was stopped too far in the process, you must
first use nsck ... destage to shut down the volume, remove and re-add
the share, then enable the volume again.
Internal problem; contact F5 personnel.
The share is designated to store namespace metadata only, so there are
no client-accessible files to import. This serves as an explanation; it is
not an import error.
No imports are possible unless the volume is enabled. Use the enable
(gbl-ns, gbl-ns-vol) command to enable the volume.
The metadata share for the volume failed to import. Use metadata share
to designate a new dedicated share for metadata.
Table 10.1 Share Status Conditions (Continued)
10 - 44
Correcting Share-Import Errors
Status Condition
Description/Action
Remove Interrupted
An administrator stopped the share removal with the cancel remove
command. To restart the removal process, use remove-share migrate,
remove-share nomigrate, no share, or no filer.
Storage job aborted.
The import process was interrupted by an nsck ... rebuild force. The
rebuild operation will re-import the share.
Storage job aborted: DNAS is shutting down.
Uninitialized (No filer assigned)
DNAS, the internal name for volume software, is shutting down. This may
be the result of administrative action, such as a remove service, during
the import. The volume has stopped running, so the import is canceled.
Use the filer command to assign a filer to the share, then retry the import.
Table 10.1 Share Status Conditions (Continued)
Restarting the Import
After you correct the problem, you can restart the import for the share. To
remove the share from the managed volume, skip ahead to the next section.
In most cases, you can restart a failed import by re-enabling it. For details on
enabling a share in a managed volume, refer to Enabling the Share, on page
9-45 of the ARX® CLI Storage-Management Guide.
For example, this command sequence successfully restarts an import for the
wwmed~/acct~budget share:
bstnA(gbl)# namespace wwmed
bstnA(gbl‐ns[wwmed])# volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# share budget
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~budget])# enable
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~budget])# ...
The alternatives below are for situations where you have reconsidered using
this share in the volume, or where the above table indicates that you must
rebuild the entire volume.
Removing the Share from the Volume
You can remove the volume from the share as a first step to retrying the
import, or as a final step.
Any imported directories and files are visible to the volume’s clients, so you
begin by choosing how to handle them. You can migrate all files and
directories to other shares in the volume, migrate only the directories, or
remove all of the share’s files and directories. The sections below describe
each of these options.
CLI Maintenance Guide
10 - 45
Chapter 10
Troubleshooting Managed Volumes
The entire volume fails if its metadata share fails or its only share fails. In
either of these cases, you must rebuild the entire volume; skip to the next
section for this situation.
Retaining Both Directories and Files in the Volume
If any files were imported from the share, you can migrate them elsewhere
in the volume before the share is removed. The files move along with the
share’s master directories. No files remain on the share after this process is
over.
Use the remove-files migrate command to migrate all files and directories to
another share before removing it from the volume. This command was
described above; see Removing an Imported Share, on page 10-18.
Note
The share with the master instance of a directory (or master directory) is
considered the “home” share for the directory. (Recall that a volume can
have a copy of any directory in multiple back-end shares.) This is the
first-imported instance of a the directory, or possibly the only instance. By
default, the volume places any new files for the directory into its master
instance.
Removing the share ensures that none of its directories are master any
longer. If the share never returns to the volume, this is irrelevant. If you add
the share back later, the volume tends to avoid putting new files onto the
share. This does not affect clients, but may create an unexpected file
distribution at the back end.
Suppose share A has two directories, “/usr” and “/log,” and you remove it
from the volume. The masters for “/usr” and “/log” migrate to another
share in the volume, share B. When share A comes back later, all new files
that clients create in “/usr” and “/log” will gravitate to share B, not share
A. Only policy can cause files to move into share A. As stated above, clients
see no difference.
For example, this command sequence removes the budget share from the
/acct volume, migrating all of its files and master directories into the “bills”
share:
bstnA(gbl)# end
bstnA# remove‐share migrate wwmed /acct budget bills
WARNING !! Share 'budget' will be removed from volume '/acct' in namespace 'wwmed' after migrating files to 'bills'
Proceed? [yes/no] yes
bstnA# ...
10 - 46
Correcting Share-Import Errors
Retaining Imported Directories (Not Files) in the Volume
To keep imported directories in the volume but remove any of the share’s
imported files, use the remove-files nomigrate command. This was described
in Removing Shares Without File Migration, on page 10-24. This moves all
of the share’s master directories into another share in the same volume, then
removes the share from the volume. Any imported files disappear from
client view.
Note
As above, the migration of the master directories places the “home” for this
share’s directories on the other share.
For example, this command sequence removes the budget share from the
/acct volume, moving all of its (empty) master directories into the “bills”
share:
bstnA(gbl)# end
bstnA# remove‐share nomigrate wwmed /acct budget bills
WARNING !! Share 'budget' will be removed from volume '/acct' in namespace 'wwmed' WITHOUT migrating files.
Proceed? [yes/no] yes
bstnA# ...
Retaining Nothing from the Share
To remove all traces of the share, you must remove all of the share’s
directories from the volume’s directory tree. This is a serious change in the
volume’s metadata, and it requires that you take the volume offline. Use
nsck ... destage to take the volume offline (recall De-Staging a Single
Volume, on page 7-38), remove the share from the volume, then re-enable
all of the volume’s remaining shares (as shown in Enabling All Shares in the
Volume, on page 9-54 of the storage-management manual).
Important
Clients cannot access the volume while it is destaged. NFS clients must
unmount and remount after the volume comes back online. Additionally, all
NFS and CIFS services that host the volume experience a brief (roughly
10-second) outage.
For example, the following command sequence shuts down the
“wwmed~/acct” volume, removes the “budget” share, and then enables all
of the remaining shares at once:
bstnA(gbl)# end
bstnA# nsck wwmed destage volume /acct
Volume /acct is in use by NFS global service 'ac1.medarch.org'.
This operation will remove entries for all shares in the volume
from the namespace metadata. To reimport a destaged share,
enable the share.
CLI Maintenance Guide
10 - 47
Chapter 10
Troubleshooting Managed Volumes
% WARNING: Volume /acct in namespace wwmed is in use by global services.
Destaging the volume will disrupt all clients using this volume.
Destage the volume anyway? [yes/no] yes
bstnA# global
bstnA(gbl)# namespace wwmed
bstnA(gbl‐ns[wwmed])# volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# no share budget
bstnA(gbl‐ns‐vol[wwmed~/acct])# enable shares
bstnA(gbl‐ns‐vol[wwmed~/acct])# ...
Reinstating the Share
If you want to bring the share back into the volume, repeat its original
configuration. When you enable the share in the already-enabled volume,
the volume imports the share’s files and directories.
For example, the following command sequence returns the “budget” share
to the “/acct” volume:
bstnA(gbl)# namespace wwmed
bstnA(gbl‐ns[wwmed])# volume /acct
bstnA(gbl‐ns‐vol[wwmed~/acct])# share budget
This will create a new share. Create share 'budget'? [yes/no] yes
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~budget])# filer das1 nfs3 /exports/budget
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~budget])# enable
bstnA(gbl‐ns‐vol‐shr[wwmed~/acct~budget])# exit
bstnA(gbl‐ns‐vol[wwmed~/acct])# ...
Reimporting the Entire Volume
The entire volume fails if its metadata-share fails or if its only share fails. In
either case, you use nsck ... rebuild volume to delete the volume’s metadata
and completely rebuild it (as described in Rebuilding a Volume, on page
7-33).
Important
This is service-affecting in the same way as nsck ... destage, described
above.
For example, this command sequence rebuilds the wwmed~/it volume:
bstnA(gbl)# end
bstnA# nsck wwmed rebuild volume /it
Reimport all shares from volume /it in namespace wwmed? [yes/no] yes
bstnA# ...
10 - 48
Removing a Full Namespace Service
Removing a Full Namespace Service
You can use a single command to remove a namespace, all of its volumes,
all the global servers and services that export its volumes, and any other
configuration objects that are used only by this namespace. All of these
components together comprise a single namespace service. From priv-exec
mode, use remove service command to remove the full namespace service:
remove service namespace [timeout seconds] [sync]
where:
namespace (1-30 characters) is the namespace to remove,
seconds (optional, 300-36,000) sets a time limit for the removal of
each namespace component, and
sync (optional) waits for the removal to finish before returning.
With this option, the CLI lists the namespace and global-server
components as it removes them.
The CLI prompts for confirmation before removing the namespace and all
of its services. Enter yes to continue.
This operation generates a report, “remService_namespace_date.rpt,” which
catalogs all of the actions that it took. The namespace in the file name
identifies the removed namespace, and the date is the date and time when
the command started. The CLI shows the report name after you invoke the
command. Use show reports to see the file listing; use show, tail, or grep to
read the file. To save the report off to an external site, use the copy ... ftp or
copy ... scp command from priv-exec mode.
The command does not create the report if you use the sync option; it shows
its actions at the command line instead.
For example, this command sequence removes the medco namespace and
later reviews the report:
bstnA(gbl)# end
bstnA# remove service medco
Remove service 'medco'? [yes/no] yes
Scheduling report: remService_medco_201002240751.rpt
bstnA# ...
bstnA# show reports remService_medco_201002240751.rpt
**** Remove Namespace Report: Started at Wed Feb 24 02:51:30 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
% COMMAND: Remove Service medco
% INFO: nsck medco destage force
% INFO: wait‐for nsck medco 300
% INFO: no enable; namespace medco
% INFO: wait‐for volume‐disable medco 300
% INFO: Checking service configuration for namespace medco
% INFO: Checking CIFS browsing for namespace medco
% INFO: Checking NFS services for namespace medco
% INFO: no nfs acopiaFiler
% INFO: Checking CIFS services for namespace medco
% INFO: Checking global servers for namespace medco
CLI Maintenance Guide
10 - 49
Chapter 10
Troubleshooting Managed Volumes
% INFO: no global server acopiaFiler
% INFO: Checking volume policies for namespace medco
% INFO: Removing Policy medco /vol
% INFO: Checking CIFS browsing for namespace medco
% INFO: Checking shares for namespace medco
% INFO: no share corporate
% INFO: no share sales
% INFO: no share generic
% INFO: Checking volume metadata shares for namespace medco
% INFO: Checking volumes for namespace medco
% INFO: no volume /vol
% INFO: Checking namespace metadata shares for namespace medco
% INFO: Checking namespace medco
% INFO: no namespace medco
% INFO: Checking NFS ACLs for namespace medco
% INFO: Checking external‐filers for namespace medco
% INFO: no external‐filer nas2
% INFO: no external‐filer nas3
**** Total processed: 0
**** Elapsed time: 00:00:08
**** Remove Namespace Report: DONE at Wed Feb 24 02:51:38 2010 ****
bstnA# ...
Removing All Policy Objects from a Namespace
You can use a single command to remove all rules, share farms, and other
policy objects from a namespace. The remove namespace command has
been described in the ARX® CLI Storage-Management Guide: see
Removing a Direct Volume, on page 8-31, Removing a Managed Volume, on
page 9-68, or Removing a Namespace, on page 7-26. Add the optional
policy-only keyword to remove only the policy objects:
remove namespace name policy‐only [timeout seconds] [sync]
where:
name (1-30 characters) is the name of the namespace,
policy-only is the option to remove only the policy objects,
seconds (optional, 300-10,000) sets a time limit on each of the
removal’s component operations, and
sync (optional) waits for the removal to finish before returning.
With this option, the CLI lists the policy objects as it removes
them.
The CLI prompts for confirmation before removing the policy objects. Enter
yes to continue. This operation generates a report named
“removeNs_namespace_date.rpt” if you omit the sync option.
For example, this command sequence exits to priv-exec mode and then
synchronously removes all policy objects from the “insur_bkup”
namespace:
prtlndA(gbl)# end
prtlndA# remove namespace insur_bkup policy‐only timeout 600 sync
Remove components from namespace 'insur_bkup'? [yes/no] yes
% INFO: Removing service configuration for namespace insur_bkup
10 - 50
Removing a Full Namespace Service
% INFO: Removing volume policies for namespace insur_bkup
% INFO: destroy policy insur_bkup /insurShdw
prtlndA# ...
Removing All Policy Objects from a Volume
The optional volume argument focuses the remove namespace command on
one volume:
remove namespace name volume volume policy‐only [timeout seconds] [sync]
where:
name (1-30 characters) is the name of the namespace,
volume (1-1024 characters) is the path name of the volume,
policy-only is the option to remove only the policy objects, and
seconds (optional, 300-10,000) sets a time limit on each of the
removal’s component operations, and
sync (optional) waits for the removal to finish before returning, as
described above.
For example, this command sequence exits to priv-exec mode and then
removes all policy objects from the “insur~/claims” volume:
bstnA(gbl)# end
bstnA# remove namespace insur volume /claims policy‐only
Remove policy components from volume '/claims' in namespace 'insur'? [yes/no] yes
...
CLI Maintenance Guide
10 - 51
Chapter 10
Troubleshooting Managed Volumes
Managing Namespace Collisions
When a managed volume is enabled, the ARX takes inventory from all of
the volume’s back-end shares and includes their files into the volume. An
important part of this process is to ensure that there is only a single instance
of any given path or file name. If you have a path or file name that is
identical on more than one back-end share, there is an import collision; only
one of the files can be imported into the managed volume. The redundant
file is renamed as follows:
file-name_share-jobid.ext
where
file-name is the file’s original name, without its extension (for
example, “myfile” from “myfile.doc”),
share is the name of the namespace share,
jobid is an integer identifying the job that imported the share, and
.ext is the files original extension (for example, “doc”), if there is
one.
If there is more than one redundant file, an index is added:
file-name_share-jobid-index.ext
where index is a number starting at 1.
The same naming conventions are applied to a directory whose name
matches an already-imported file, or to a directory that has different file
attributes than an already-imported directory. In addition, any tilde (~)
characters in a directory name are replaced with commas (,).
Finding the Renamed Files
To find any files that have collided and been renamed, you can view the
report that was generated during import. Each share generates one import
report each time it imports (import occurs when the share and volume are
first enabled, or if you use nsck ... rebuild to rebuild the volume). Use the
show reports type Imp command to see all import reports.
For example, this switch has several import reports:
bstnA(cfg)# show reports type Imp
reports
Codes: Imp=Import
import.1.budget.5.rpt Feb 24 00:57 1.9 kB Imp DONE: 713 in 00:00:04
import.10.backlots.17.rpt Feb 24 01:00 2.0 kB Imp DONE: 1 in 00:00:04
import.11.scanners.18.rpt Feb 24 01:00 2.2 kB Imp DONE: 5 in 00:00:03
import.12.shr1‐old.26.rpt Feb 24 01:14 5.6 kB Imp DONE: 161 in 00:00:08
import.13.shr1‐next.27.rpt Feb 24 01:14 2.5 kB Imp DONE: 14 in 00:00:08
import.2.bills.6.rpt Feb 24 00:57 1.9 kB Imp DONE: 122 in 00:00:03
import.3.bills2.7.rpt Feb 24 00:57 2.5 kB Imp DONE: 415 in 00:00:03
import.4.it5.8.rpt Feb 24 00:58 1.9 kB Imp DONE: 131 in 00:01:01
10 - 52
Managing Namespace Collisions
import.5.rx.11.rpt Feb 24 00:59 1.8 kB Imp DONE: 31 in 00:00:06
import.6.charts.12.rpt Feb 24 00:59 2.1 kB Imp DONE: 160 in 00:00:06
import.7.bulk.13.rpt Feb 24 00:59 1.9 kB Imp DONE: 4 in 00:00:06
import.8.equip.15.rpt Feb 24 00:59 1.8 kB Imp DONE: 19 in 00:00:04
import.9.leased.16.rpt Feb 24 01:00 1.9 kB Imp DONE: 42 in 00:00:04
bstnA(cfg)# Use show reports file-name to view the import report. A collision appears in
the File Scan Phase section, with a Type of “R” (Rename) and “NC” (name
collision). For example, the following report shows three collided files
(highlighted in bold):
bstnA(cfg)# show reports import.3.bills2.7.rpt
**** Share Import Report: Started at Wed Feb 24 00:57:49 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: wwmed
**** Volume: /acct
**** Share: bills2
**** IP Addr: 192.168.25.23
**** Export: /exports/acct2
**** Options:
**** modify: yes
**** rename‐directories: yes
**** rename‐non‐mappable‐directories: no
**** rename‐files: yes
**** sync‐attributes: yes
**** skip‐managed‐check: no
**** import protection: yes
**** import treewalk‐threads: 8
**** import priority: 65535 (Lowest)
**** NOTE: Since both sync‐attributes and rename‐directories were specified,
**** only directories that collide with existing filenames will be
**** renamed. Directories with colliding attributes will have their
**** attributes synchronized to the namespace.
**** Ignore List:
**** .snapshot
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[bills2 ] 192.168.25.23:/exports/acct2
**** LEGEND
****
**** Actions
**** R : Entry renamed.
**** S : Directory attributes synchronized.
**** ? : Indicates additional settings or operations required for full
**** operation. See specific issues for SD and IN below.
**** ! : Unable to resolve given specified options or configuration.
****
**** Entry Type
**** F : Entry is a file.
**** D : Entry is a directory.
****
**** Issue
CLI Maintenance Guide
10 - 53
Chapter 10
Troubleshooting Managed Volumes
**** NC : Name collision.
**** AC : Attribute collision.
**** RA : Attributes of share root are inconsistent.
**** MG : Subdirectory of this share is already imported as managed share.
**** CC : Case‐blind collision (MPNS and CIFS‐only).
**** MC : Maximum name collisions for this name in a directory
**** ER : Entry removed directly from filer during import.
**** AE : Error accessing entry.
**** RV : Reserved name on filer not imported.
**** DF : DFS link found during import.
**** TC : Trailing character: space and period are not supported by all filer vendors.
**** HL : Exceeded limit of 1024 hard links to a file.
**** @@ : Other error.
Import Scan:
================================================================================
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Import Scan Start Time: Wed Feb 24 00:57:51 2010
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Type Path
‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[S D AC] /payable/
Differing Attributes: NFS Mode Bits
[R F NC] /index.html ‐> index_bills2‐3.html
[R F NC] /payable/FrontMatter.fm ‐> FrontMatter_bills2‐3.fm
[R F NC] /payable/variables.fm ‐> variables_bills2‐3.fm
Directories found: 31
Files found: 384
Directories Scanned/Second: 31
Files Scanned/Second: 384
Total Entries Scanned/Second: 415
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Import Scan Stop Time: Wed Feb 24 00:57:52 2010
Import Scan Elapsed Time: 00:00:01
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Directories imported by scan: 31
Directories imported dynamically: 0
Files imported by scan: 384
Files imported dynamically: 0
Directories renamed due to name/attribute conflict: 0
Files renamed due to name conflict: 3
Directory attributes synchronized: 1
**** Elapsed time: 00:00:03
**** Share Import Report: DONE at Wed Feb 24 00:57:52 2010 ****
Correcting the Collisions
To rename a duplicate file, access the virtual IP (VIP) for the volume as a
client would, and rename or move the file as desired.
10 - 54
Managing Collisions With CIFS 8.3 Names
Managing Collisions With CIFS 8.3 Names
Volumes that support CIFS have an additional possible naming-collision
obstacle, caused by back-end servers keeping an extra name for some files
and directories. Windows once ran on file systems (such as FAT12 and
FAT16) that supported only short file names, sometimes called 8.3 names.
An 8.3 name uses the following format:
base-name[.ext]
where
• base-name is 1-8 characters,
• . is optional, and
• ext is 1-3 characters.
Newer Windows servers run NTFS, which supports file and directory names
of any length. Other file systems that support CIFS also support names of
any length. For backwards compatibility, these contemporary file systems
continue to support an alternate 8.3 name for any file or directory that does
not fit the above pattern. The alternate name is sometimes called a
filer-generated name (FGN) since it is created by the filer. The longer name
is called the primary name. Contemporary Windows clients see the primary
name while older Windows applications see only the alternate name, the 8.3
FGN. Contemporary applications can use either name to access the file or
directory, though, by default, they do not see the alternate name.
The 8.3-FGN Pattern
Filers generate alternate 8.3 names with specific patterns, usually including
a tilde (~) character to indicate that the name is filer-generated. Any 8.3
FGN falls into one of two patterns:
name-with-tilde[.ext]
is the most-common pattern, where
•
name-with-tilde (2-8 characters) has one tilde (~) character
(such as “RANDOM~2”), and
•
ext is optional and has 1-3 characters.
name-without-tilde[.ext]
is a pattern that EMC file servers use in some cases, where
CLI Maintenance Guide
•
name-without-tilde (exactly 8 characters) has no tilde (~)
character (such as “0000D773”), and
•
ext is optional and has 1-3 characters.
10 - 55
Chapter 10
Troubleshooting Managed Volumes
8.3 FGNs Do Not Exist in an ARX Volume
Any 8.3 FGNs that appear when you access the filer directly (such as
“KMO_ME~1.DAT”) do not appear in the client view of the managed
volume. The managed volume keeps only the primary name for the file
(“kmo_medical_record.dat” in this example); files and directories are not
accessible by their filer’s alternate names.
Best Practice: Avoid Primary Names That Match The 8.3 Pattern
F5 Networks recommends strongly that you disable the creation of 8.3
FGNs on your back-end filers. There is no penalty for disabling this, since
the 8.3 FGNs are not accessible through the ARX, anyway. Windows and
Samba both are able to disable altname generation, and Microsoft itself
recommends the practice.
If a primary name matches the pattern for an 8.3 FGN, it collides with any
matching alternate name on another share. For example, consider a file on
share A with a primary name of “MYFILE~1” and a different file on share
B named “myFileForYouToRead.” If the latter file has an alternate name of
“MYFILE~1,” it collides with the file on share A. For the same reason,
migration of such a file from share A to B will fail.
8.3 FGN Collision Avoidance
If a client attempts to create a file that matches an 8.3 FGN on a back-end
filer, the ARX will execute collision prevention measures on the target share
automatically. If this is successful, the file creation request will be processed
normally, and the result from the file server will be returned to the client. If
the collision prevention behavior fails, a relevant error code will be returned
instead.
If an 8.3 FGN collision is recognized on the back-end filer, the ARX will:
• Attempt to clear the colliding 8.3 FGN on the back-end filer. This works
only on newer versions of Windows filers. The primary file name will
remain the same.
• Change the colliding 8.3 FGN explicitly by instructing the filer to change
it. (This works only on Windows.)
• Change the 8.3 FGN implicitly by renaming the colliding file (thus
indirectly causing the file server to change its 8.3 FGN). (This works on
all filers.) This change is temporary and is never visible via the ARX
VIP.
The ARX metadata is not affected by any attempt to clear or change the 8.3
FGN.
10 - 56
Managing Collisions With CIFS 8.3 Names
Identifying 8.3 FGN Collisions
Run an nsck-inconsistencies report (recall Finding Metadata
Inconsistencies, on page 7-16) to identify 8.3 name collisions. Each file with
this issue is flagged with “F8,” and each directory is flagged with “D8.”
For example, this command sequence generates and shows an
inconsistencies report for the “medarcv” namespace, which reveals one file
collision and one directory collision (highlighted in bold text):
bstnA# nsck medarcv report inconsistencies /rcrds outputfile rcrdsIssues
Scheduling report: rcrdsIssues.rpt on switch bstnA
bstnA# show reports rcrdsIssues.rpt
**** Inconsistencies Report: Started at Wed Feb 24 01:58:00 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: medarcv
**** Volume: /rcrds
**** Path: /rcrds
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[rx ] 192.168.25.29:prescriptions
[charts ] 192.168.25.20:histories
[bulk ] 192.168.25.27:bulkstorage
**** Legend:
**** LF = File exists in the metadata, but is missing from the physical filer.
**** LD = Directory exists in the metadata, but is missing from the physical filer.
**** FF = File exists on the physical filer, but is missing from the metadata.
**** FD = Directory exists on the physical filer, but is missing from the metadata.
**** LL = File is a symlink in the metadata, but is a regular file on the filer.
**** FL = File is a symlink on the filer, but is a regular file in the metadata.
**** IF = Filehandles in the metadata do not match the filehandles on the physical filer.
**** MF = The file is currently being migrated.
**** NL = Unable to lock parent directory during report.
**** FE = Error contacting filer during report.
**** FO = Filer Offline: The filer is offline or disabled.
**** F8 = A file name matches a CIFS alternate "8.3" name on another share.
**** D8 = A directory name matches a CIFS alternate "8.3" name; its contents will be skipped.
**** DC = A client has the file or directory open for delete‐on‐close, but the filer has already deleted it.
**** SD = Striped leaf directory found on filer, expected on other shares.
**** SL = File is a symlink.
**** UT = Name contains characters that are invalid UTF‐8; must solve issue directly on the filer
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[LF ] [charts ] /copyRandomx.exe
[ F8 ] [charts ] /KMO_ME~1.DAT ‐> kmo_medical_record.dat
[ D8 ] [charts ] /RECORD~1/ ‐> records_predating_y2k
**** Total Found Items: 0
**** Total Lost Items: 1
**** Total Invalid Filehandles: 0
**** Total Migrating Files: 0
**** Total Deleted Before Close: 0
**** Total Locking Errors: 0
**** Total Filer Errors: 0
**** Total 8.3 Errors: 2
**** Total Found Stripes: 0
CLI Maintenance Guide
10 - 57
Chapter 10
Troubleshooting Managed Volumes
**** Total processed: 188
**** Elapsed time: 00:00:00
**** Inconsistencies Report: DONE at Wed Feb 24 01:58:00 2010 ****
bstnA# ...
Correcting 8.3 Name Collisions Manually
In the event that the ARX’s 8.3 name collision avoidance behavior does not
resolve an 8.3 name collision automatically, you can use the same method to
correct 8.3 name collisions that you use with standard collisions: access the
VIP as a client and rename the offending file or directory. The entry to
rename is the one with a primary name that matches the 8.3-FGN pattern.
This is the first name shown in the inconsistencies report
(“KMO_ME~1.DAT” and “RECORD~1” in the above example).
10 - 58
Fixing File/Directory Names with Trailing Periods
Fixing File/Directory Names with Trailing Periods
This section applies only to managed volumes that support CIFS. You can
skip this section if you are using NFS-only volumes and/or direct volumes.
CIFS-filer vendors are inconsistent in their handling of two illegal trailing
characters in file/directory names, period (.) and space ( ). Some CIFS
implementations strip the trailing character from the end of the name at
creation time, some reject the name with an error, and others replace any
trailing-period name with an FGN. This inconsistent handling poses a
problem for a volume backed by multiple CIFS vendors: a file on one
back-end share may have its name changed to an FGN if it migrates to
another. To avoid this situation, a CIFS-only volume identifies filers that
create FGNs for trailing-period names, and does not allow clients to create
these names on those filers.
CIFS-only volumes use special processing for trailing-period names. (The
period, not the space, is the trailing character that triggers an FGN on some
filers.) The following subsections describe this special processing.
Note
This special processing occurs only in volumes where at least one share
converts trailing-period names into FGNs.
Illegal Client Operations
CIFS-only volumes prevent the following client operations if (and only if)
they are backed by any filer that converts trailing-period names to FGNs:
◆
Clients cannot create any new file or directory with a trailing period in
these volumes.
◆
Clients cannot rename an existing file or directory so that the new name
has a trailing period.
◆
The volume also blocks some client operations inside a directory with a
trailing-period name. For example, creating the file,
“\myvol\mydir.\newFile.txt”, could fail because of the period at the end
of the parent directory’s name, “\mydir.”. The volume would block this if
it meant that the volume would have to replicate “\mydir.” on a filer that
would change it into an FGN.
The final case is subtle, and may require a search through the syslog file
(recall Accessing the Syslog, on page 8-7) to prove that a trailing-period is at
fault. Search for the string “TRAIL” for syslog messages about illegal
trailing periods. Use grep TRAIL logs syslog to search for messages about
trailing periods, or grep ip-address logs syslog to find all messages
concerning a client at ip-address.
CLI Maintenance Guide
10 - 59
Chapter 10
Troubleshooting Managed Volumes
Finding Imported Files with Illegal Trailing Characters
Files or directories with trailing-period names may have existed before
import. These files and directories are flagged with the letters “TC” (for
Trailing Character) in a CIFS share’s import report. For example, this
import report finds two directories and one file that end with a period. The
file and directories are highlighted below in bold text:
bstnA# show reports import.6.charts.12.rpt
bstnA# show reports import.6.charts.12.rpt
**** Share Import Report: Started at Wed Feb 24 00:59:42 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: medarcv
**** Volume: /rcrds
**** Share: charts
**** IP Addr: 192.168.25.20
**** Export: histories
**** Options:
**** modify: yes
**** rename‐directories: yes
**** rename‐non‐mappable‐directories: no
**** rename‐files: yes
**** sync‐attributes: yes
**** skip‐managed‐check: no
**** import protection: yes
**** import treewalk‐threads: 8
**** import priority: 65535 (Lowest)
**** NOTE: Since both sync‐attributes and rename‐directories were specified,
**** only directories that collide with existing filenames will be
**** renamed. Directories with colliding attributes will have their
**** attributes synchronized to the namespace.
**** Ignore List:
**** .snapshot
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[charts ] 192.168.25.20:histories
**** LEGEND
****
**** Actions
**** R : Entry renamed.
**** S : Directory attributes synchronized.
**** ? : Indicates additional settings or operations required for full
**** operation. See specific issues for SD and IN below.
**** ! : Unable to resolve given specified options or configuration.
****
**** Entry Type
**** F : Entry is a file.
**** D : Entry is a directory.
****
**** Issue
**** NC : Name collision.
**** AC : Attribute collision.
**** RA : Attributes of share root are inconsistent.
10 - 60
Fixing File/Directory Names with Trailing Periods
**** MG : Subdirectory of this share is already imported as managed share.
**** CC : Case‐blind collision (MPNS and CIFS‐only).
**** MC : Maximum name collisions for this name in a directory
**** ER : Entry removed directly from filer during import.
**** AE : Error accessing entry.
**** RV : Reserved name on filer not imported.
**** DF : DFS link found during import.
**** TC : Trailing character: space and period are not supported by all filer vendors.
**** HL : Exceeded limit of 1024 hard links to a file.
**** @@ : Other error.
Import Scan:
================================================================================
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Import Scan Start Time: Wed Feb 24 00:59:48 2010
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Type Path
‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ D TC] /2007/late_test_results.
[ D TC] /2004/planR.
[ F TC] /2007/hlo_medical_record.dat.
Directories found: 19
Files found: 141
Directories Scanned/Second: 19
Files Scanned/Second: 141
Total Entries Scanned/Second: 160
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Import Scan Stop Time: Wed Feb 24 00:59:48 2010
Import Scan Elapsed Time: 00:00:01
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Directories imported by scan: 19
Directories imported dynamically: 0
Files imported by scan: 141
Files imported dynamically: 0
Directories renamed due to name/attribute conflict: 0
Files renamed due to name conflict: 0
Directory attributes synchronized: 0
**** Elapsed time: 00:00:06
**** Share Import Report: DONE at Wed Feb 24 00:59:48 2010 ****
bstnA# ...
Finding Shares That Convert Trailing-Period Names to FGNs
You can use the show namespace command to find if a particular share
converts trailing-period names into FGNs: the no-trail-period flag appears
in the share’s Features field.
For example, this command shows that the “swic~/users~samba1” share
performs the FGN conversion:
bstnA# show namespace swic volume /users share samba1
Namespace "swic" Configuration
CLI Maintenance Guide
10 - 61
Chapter 10
Troubleshooting Managed Volumes
Description: (none)
Metadata Cache Size: 512 MB
Proxy User: swi_admin
Filer SMB Signatures: Enabled
SAM Reference Filer: win‐1 (192.168.81.30)
Supported Protocols
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
cifs
CIFS Authentication
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Protocols:
NTLM
NTLMv2
Anonymous (IPC$ only)
Character Encoding
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
cifs ISO‐8859‐1
Participating Switches
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
bstnA (volume‐group 1) [Current Switch]
Windows Management Authorization Policies
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
mmcAdmin
Volumes
‐‐‐‐‐‐‐
/users
CIFS : compressed files: yes; named streams: yes; persistent ACLs: yes
sparse files: yes; Unicode on disk: yes; case sensitive: no
Volume freespace: 10 GB (automatic)
Volume total space: 19 GB
CIFS quotas: Not Enabled
Auto Sync Files: Enabled
Metadata size: 104 kB
Metadata free space: 46 GB
Filer Subshares: Enabled
Oplock support: Enabled
Notify‐change mode: Normal
CIFS path cache: Enabled
CIFS access based enum: Not Enabled
Snapshots: Not Enabled
Migration method: Staged
State: Enabled
Host Switch: bstnA
Instance: 1
Volume‐group: 1
Processor: 5.1
Files: 70 used (35 dirs), 3.9 M free, 252 M max (automatic)
Metadata shares:
Filer Backend Path Contains Metadata Status
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
swi‐nas /vol/datavol1/exports/aco_meta Yes Online
10 - 62
Fixing File/Directory Names with Trailing Periods
Share samba1
Description home dirs for Windows users
Filer smb‐1 [192.168.81.3]
CIFS Share wusers
Features cifs‐acls cifs‐case‐blind
CIFS Maximum Request Size 16644
SID Translation No
Ignore SID errors No
Status Online
Volume Root Backing Yes
Import Sync Attributes Yes
Import Skip Managed Check Yes
Import Priority 65535 (Lowest)
Free space on storage 10 GB (11,700,883,456 B)
Total space on storage 19 GB (21,472,735,232 B)
Policy Maintain Freespace: 1.0 GB
Policy Resume Freespace: 2.0 GB
Transitions 1
Last Transition Mon 23 Aug 2010 03:32:14 AM EDT
bstnA# ...
Disallowed Migrations and Replications
A managed volume never migrates a file or directory with a trailing period
to a filer that would convert it to an FGN. Specifically, volumes avoid the
following autonomous operations:
• file migrations through file-placement rules (see Placing Files on
Particular Shares, on page 14-4 of the ARX® CLI Storage-Management
Guide),
• directory striping (to facilitate a file migration), or
• file or directory replications to a shadow volume (see Configuring a
Shadow-Copy Rule (Source Switch), on page 16-9 of the same manual).
Stopped migrations and replications are enumerated in file-placement
reports and shadow-copy reports.
Migrating Storage Between Filer Vendors
Some sites use the ARX to move storage from filer to filer. If the source
filer allows these illegal trailing characters but the destination filer does not,
you must manually change these names before the migration. The best
practice for this migration varies from site to site. You can contact F5
Support to help choose the best method for your site.
CLI Maintenance Guide
10 - 63
Chapter 10
Troubleshooting Managed Volumes
Finding NFS-Only Entries in a Multi-Protocol Volume
This section applies to volumes in a multi-protocol (CIFS and NFS)
namespace only, where the CIFS name and the NFS name for a file may
differ.
Some file/directory names are legal in NFS but illegal in CIFS, or are legal
in CIFS but illegal in NFS. Most multi-protocol filers use the original name
for the clients of one protocol, then create a new filer-generated name
(FGN) for the clients of the other protocol. The ARX aggregates the naming
solutions from several multi-protocol vendors, each following a different
standard for FGNs. Every file or directory must have an NFS-side name that
matches its CIFS-side name on every share, or it is marked as NFS-only.
Best Practice: Avoid NFS-Only Entries Where Practical
CIFS clients cannot access an NFS-only entry. This is especially a problem
for directories, which obscure all of their contents including all child
directories.
Performance Issues
NFS-only entries, under rare circumstances, can also impede volume
performance. The volume does not record any FGNs from its filers; instead,
it probes for FGNs only when a collision with an FGN is possible. An FGN
collision can only occur in a directory that has one of two problems: either it
contains NFS-only entries, or it contains a name that matches an FGN
pattern (like “FILE~2.txt”).
A directory with any NFS-only entries is certain to have at least one FGN on
its filers. If a client creates a name there that might match an FGN pattern
(such as “myfile~1.doc” or “dir~1”), the volume first probes all its back-end
shares to verify that the FGN is not already taken. If the FGN is taken, the
client’s new file is marked “NFS-only.”
A directory with any FGN-patterned names introduces the opposite
problem: a new NFS-only entry can create a back-end FGN that collides
with an existing entry. In this case, the pre-existing entry with the
FGN-patterned name becomes “NFS-only.” For example, if “MYFILE~1”
already exists in a directory and a client creates “myFile?,” the volume must
probe the back-end shares to see if any of them created a “MYFILE~1”
FGN. If the FGN is found, the original “MYFILE~1” entry becomes
“NFS-only.”
Evidence from the field demonstrates that these collision checks are rarely
necessary, though they do affect performance when they occur.
The policy engine is subject to this collision check like any external client.
10 - 64
Finding NFS-Only Entries in a Multi-Protocol Volume
Identifying Problematic Entries
If CIFS clients complain about access issues or slow performance, you
should identify the NFS-only entries in the volume and work toward
changing their names. This is especially true for directory names, which can
obscure multiple files and directories from CIFS users. Run an
nsck-inconsistencies report with the multi-protocol flag (recall Focusing on
Multi-Protocol Issues, on page 7-18) to reveal all NFS-only file names and
directory names. Each of them is flagged with an “NF.” For example, this
command sequence generates and shows an inconsistencies report for the
“insur” namespace, which reveals several NFS-only files and directories:
bstnA# nsck insur report inconsistencies multi‐protocol outputfile insur_fgns
Scheduling report: insur_fgns._claims.rpt on switch bstnA
bstnA# show reports insur_fgns._claims.rpt
**** Inconsistencies Report: Started at Wed Feb 24 01:58:49 2010 ****
**** Software Version: 5.02.000.12538 (Feb 16 2010 20:14:13) [nbuilds]
**** Hardware Platform: ARX‐4000
**** Report Destination:
**** Namespace: insur
**** Volume: /claims
**** Path: /claims
**** multiprotocol flag specified
Share Physical Filer
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[shr1‐old ] 192.168.25.21 NFS:/vol/vol1/NTFS_QTREE/insurance, CIFS:insurance
[shr1‐next ] 192.168.25.51 NFS:/root_vdm_4/patient_records, CIFS:patient_records
**** Legend:
**** LF = File exists in the metadata, but is missing from the physical filer.
**** LD = Directory exists in the metadata, but is missing from the physical filer.
**** FF = File exists on the physical filer, but is missing from the metadata.
**** FD = Directory exists on the physical filer, but is missing from the metadata.
**** LL = File is a symlink in the metadata, but is a regular file on the filer.
**** FL = File is a symlink on the filer, but is a regular file in the metadata.
**** IF = Filehandles in the metadata do not match the filehandles on the physical filer.
**** MF = The file is currently being migrated.
**** NL = Unable to lock parent directory during report.
**** FE = Error contacting filer during report.
**** FO = Filer Offline: The filer is offline or disabled.
**** F8 = A file name matches a CIFS alternate "8.3" name on another share.
**** D8 = A directory name matches a CIFS alternate "8.3" name; its contents will be skipped.
**** DC = A client has the file or directory open for delete‐on‐close, but the filer has already deleted it.
**** SD = Striped leaf directory found on filer, expected on other shares.
**** SL = File is a symlink.
**** UT = Name contains characters that are invalid UTF‐8; must solve issue directly on the filer
****
**** Multi‐Protocol Only:
**** NF = Name is accessible only to NFS clients.
**** NI = Name does not exist via both NFS and CIFS.
**** CC = Case‐blind name collision.
**** IC = CIFS invalid characters found in NFS name.
**** FN = A portion of the name contains a filer‐generated pattern.
**** NM = CIFS name has characters that are not mappable to the NFS encoding.
**** SP = A NFS name in the path's ancestry will prevent CIFS access.
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ NF CC ] [shr1‐old ] /INDEX.html
CLI Maintenance Guide
10 - 65
Chapter 10
Troubleshooting Managed Volumes
[ NF CC ] [shr1‐old ] /index.html
[ NF CC ] [shr1‐old ] /Tools
[ NF CC ] [shr1‐old ] /tools
[ NF IC ] [shr1‐old ] /Claims:2001
[ NF IC ] [shr1‐old ] /claims:2005
[ NF IC ] [shr1‐old ] /draft_proposals.
[ F8 ] [shr1‐old ] /OVERDU~1.DOC ‐> overdueclaimsmemo.doc
[ D8 ] [shr1‐old ] /Y2KCLA~1/ ‐> y2kclaims
[ SP] [shr1‐old ] /draft_proposals./FY06challenges.ppt
[ SP] [shr1‐old ] /draft_proposals./claim2389_rebut2.doc
[ SP] [shr1‐old ] /draft_proposals./FY2007propB.ppt
[ SP] [shr1‐old ] /draft_proposals./claim2389_rebut1.doc
[ NF IC ] [shr1‐old ] /images/FRU replace wrongway.tif
[ NF IC ] [shr1‐old ] /images/:D1JL100
[ NI NM ] [shr1‐old ] /images/file012bÄ«/ (Characters: U+012b)
[ NF CC ] [shr1‐old ] /stats/piechart.ppt
[ NF CC ] [shr1‐old ] /stats/PieChart.ppt
[ NF IC ] [shr1‐old ] /stats/on_the_job:2004.cnv
[ NF IC ] [shr1‐old ] /stats/on_the_job:2003.cnv
[ NF IC ] [shr1‐old ] /stats/in_home:2005
[ SP] [shr1‐old ] /tools/extractCdDocs.pl
[ SP] [shr1‐old ] /tools/cleanBU.csh
[ SP] [shr1‐old ] /tools/checkinAll.pl
[ SP] [shr1‐old ] /tools/docSet.pl
[ SP] [shr1‐old ] /tools/updateCvs.csh
[ SP] [shr1‐old ] /tools/books.xml
[ SP] [shr1‐old ] /tools/blowAway.pl
[ SP] [shr1‐old ] /tools/makeCd.pl
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:11‐21yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:>21yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:<10yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:>21yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:<10yrs.csv
[ NF IC ] [shr1‐old ] /stats/in_home:2005/age:11‐21yrs.csv
[ SP] [shr1‐old ] /stats/in_home:2005/age:<10yrs.csv
[ SP] [shr1‐old ] /stats/in_home:2005/age:>21yrs.csv
[ SP] [shr1‐old ] /stats/in_home:2005/age:11‐21yrs.csv
**** Total Found Items: 0
**** Total Lost Items: 0
**** Total Invalid Filehandles: 0
**** Total Migrating Files: 0
**** Total Deleted Before Close: 0
**** Total Locking Errors: 0
**** Total Filer Errors: 0
**** Total 8.3 Errors: 2
**** Total Found Stripes: 0
**** Total processed: 171
**** Elapsed time: 00:00:01
**** Inconsistencies Report: DONE at Wed Feb 24 01:58:50 2010 ****
The remaining subsections describe the various types of NFS-only files and
directories, and discuss methods for finding and fixing them.
10 - 66
Finding NFS-Only Entries in a Multi-Protocol Volume
Case-Blind Collisions (CC)
A case-blind collision occurs when two or more entries in the same parent
directory have names that differ only in case (for example, “index.html” and
“INDEX.html”). CIFS does not support case collisions, but NFS does.
These are created by NFS clients, either before import or while the volume
is in service.
A file with a case-blind collision is marked with a “CC” in the
inconsistencies report. For example (from the inconsistencies report above):
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ NF CC ] [shr1‐old ] /index.html
[ NF CC ] [shr1‐old ] /INDEX.html
...
Note
If a directory contains more than 1,024 case collisions, its parent directory
incurs an additional performance penalty if it checks for FGN collisions
during metadata-intensive operations (share import, restore data, all nsck
operations, and sync). The FGN-collision check was described in
Performance Issues, on page 10-64.
Names with Characters that are Illegal in CIFS (IC)
The following characters are legal in NFS file names but illegal in their
CIFS counterparts: any control character, /, \, :, *, ?, >, <, ”, or |.
Additionally, a trailing period (.) or a trailing space character is illegal in a
CIFS name; recall Fixing File/Directory Names with Trailing Periods, on
page 10-59. Files and directories with any of these illegal CIFS characters
are NFS-only. Like case collisions, these are created by NFS clients.
Each entry with illegal CIFS characters is flagged with an “IC” (for “Illegal
Character”) in the inconsistencies report. For example, this file is NFS-only
because of the colon (:) in its name:
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
...
[ NF IC ] [shr1‐old ] /stats/on_the_job:2004.cnv
CLI Maintenance Guide
10 - 67
Chapter 10
Troubleshooting Managed Volumes
Client View: ARX-Generated Names
A managed volume creates its own ARX-generated names (AGNs) for files
or directories with illegal CIFS characters. The volume presents the AGN to
its CIFS clients. The AGN has a unique format, easily distinguishable from
the formats of any FGNs:
(!) nnn_changed-file-name
Where
''(!) '' (with the trailing space) is the prefix for all AGNs.
nnn is a different number for every AGN in this directory. This number
is padded so that it is always at least three digits long.
changed-file-name is the original file name (or directory name), with
all illegal characters replaced with an underscore character (_).
For example, the above NFS-side file name (“on_the_job:2004.csv”) may
have the following AGN for CIFS clients:
(!) 001_on_the_job_2004.cnv
The ARX only generates CIFS-side AGNs. NFS-side AGNs are not possible
in the current implementation.
Unicode Characters in CIFS Names: Non-Mappable in NFS (NM)
Some illegal file or directory names may have been created by CIFS clients
before import. CIFS natively supports all Unicode characters in its file or
directory names, but NFS servers must specifically have their character
encoding configured to support them. Otherwise, many Unicode characters
are non-mappable to NFS. A multi-protocol filer set for Latin1 character
encoding may have allowed CIFS clients to use Unicode characters (such as
Korean or Japanese characters) in entry names. If so, the filer accepted the
CIFS name and created an FGN for its NFS clients.
CIFS clients cannot create this problem through the volume; the volume
only allows CIFS-side names that are fully mappable to NFS. This is an
import-only issue.
When the volume imports the share, it treats non-mappable names
differently for files and directories.
Non-Mappable File Names
For files, the volume uses the NFS-side FGN for the file name. If the FGN
contains any illegal CIFS characters (as they often do), the volume also
creates a CIFS-side AGN from that FGN. For example, consider a site that
supports Latin1, a single-byte character encoding, for its NFS clients.
Suppose (before import) a CIFS user creates a file with the following name:
file012bC
where C is a character that is not supported by the filer’s NFS character
encoding.
10 - 68
Finding NFS-Only Entries in a Multi-Protocol Volume
The filer may create an NFS-side FGN with no apparent relationship to the
original file name:
:I1A3410
The volume imports this file and uses the above name for its NFS clients.
For its CIFS clients, it creates the following AGN (since the colon character
cannot be used in a CIFS file name):
(!) 001__I1A3410
An NSCK inconsistencies report for the volume shows these files with an
“NM” flag. For example:
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
...
[ NI NM ] [shr1‐old ] /images/file012bÄ«/ (Characters: U+012b)
The CIFS-side AGN is inaccessible, but an NFS user can change the
NFS-side name (“:I1A3410” in the above example) to something that is
legal and recognizable in both protocols (for example, “file012”).
Non-Mappable Directory Names
A directory may contain a large tree of subdirectories and files, so the
import process takes greater care in keeping it accessible and easily
recognizable from both CIFS and NFS. If the volume is allowed to modify
its imported shares and rename directories in the particular share, it renames
the directory based on its CIFS name. The import for the share fails if the
volume is not allowed to both modify and rename directories; this is
discussed in Preventing Directory Renames During Import, on page 9-38 of
the ARX® CLI Storage-Management Guide.
The directory renames follow the pattern below. The volume replaces each
unmappable CIFS character with its numeric equivalent:
new-dirname_share-jobid[-index][.ext]
where new-dirname is the original CIFS-side name, but with
“(U+nnnn)” in place of each unmappable character. The nnnn is the
Unicode number for the character, shown in hexadecimal format. The
name is truncated if it exceeds 256 characters. For example,
“dir(U+30D2)(U+30AA)_myshare-2.”
The share’s import report includes the original name and the new name for
each renamed directory. The directory does not appear in the inconsistencies
report, as its new name is legal in both protocols.
Split Directories (SP)
Any NFS-only directory is called a split directory. All descendents of split
directories are flagged with an “SP” in the inconsistencies report; they are
flagged because they are inaccessible to CIFS clients. For example, here is a
split directory and its descendents:
Type Share Path
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
[ NF CC ] [shr1‐old ] /tools
CLI Maintenance Guide
10 - 69
Chapter 10
Troubleshooting Managed Volumes
...
[ SP] [shr1‐old ] /tools/extractCdDocs.pl
[ SP] [shr1‐old ] /tools/cleanBU.csh
...
“Marked” Directories
Some multi-protocol directories are marked in the metadata for
FGN-collision checking. A directory is marked for this processing if it
contains entries with either of the following name issues:
• NFS-only (such as “my?dir,” or “MYDIR” and “mydir” together), and/or
• matching an FGN pattern (such as “my~dir”).
If the directory contains either of these name types, the volume must check
for FGN collisions every time a client creates a name of the other type. The
FGN-collision check was described earlier, in Performance Issues, on page
10-64. This check occurs for all types of clients, including the policy engine;
that is, the volume also performs extra checking before migrating any
FGN-related files or subdirectories from one back-end share to another.
A directory remains “marked” for this checking even if clients remove all
NFS-only and FGN-matching entries from it. You can remove the mark by
emptying the directory completely, or by cleaning out all entries with FGN
issues and running sync files on it. The latter option is described later in this
section.
Preventative Striping
Another disadvantage for a marked directory can be extra back-end copies
(called stripes) for some of its NFS-only subdirectories. Before the policy
engine migrates any NFS-only file (such as “newFile” in a directory that
already contains “NEWFILE”), it stripes all of its subdirectories that fit an
FGN pattern (such as “DIR~3”) to the target share. Then it migrates the file.
This ensures that the subdirectories remain open to both CIFS and NFS. It
also creates extra, unexpected directory stripes on the back-end target share.
Correcting NFS-Only Entries
To remove the “NFS-only” flag from a file or directory, an NFS client can
access the volume’s front-end service and rename the offending entry from
there. Choose a name that is valid in both protocols. For example, here are
some NFS-only issues and possible solutions:
• Case collision (“index.html” and “INDEX.HTML” in the same directory)
Rename “INDEX.HTML” to “index2.html.”
• Illegal CIFS characters (“on_the_job:2004.csv”)
Rename to “on_the_job_2004.csv,” to eliminate the illegal colon (:).
• Name with an FGN pattern (“OVERDU~1.DOC”) that collides with an
actual FGN.
10 - 70
Finding NFS-Only Entries in a Multi-Protocol Volume
Rename to “overdue_1.doc” to remove the tilde (~).
You can correct a marked directory by correcting all of the NFS-only entries
within it.
After the rename(s), you must run the sync files ... recurse command to
remove the NFS-only flags from the volume’s renamed files and directories.
The sync utility probes all of the volume’s shares to confirm that no FGN
collisions exist. This also removes the marks from any directories that no
longer contain any NFS-only entries. The sync files command was described
in an earlier chapter: recall Synchronizing Metadata with Actual Files, on
page 7-22.
For example, the following command sequence exits to priv-exec mode and
synchronizes the metadata in the “insur~/claims” volume:
bstnA(gbl)# end
bstnA# sync files insur volume /claims path / recurse
Scheduling sync files operation on switch bstnA, report name: sync.7._rcrds.rpt
bstnA# ...
Recursively Correcting Split Directories
In any split directories that have been corrected, the sync utility probes all
child entries, including child directories, for the first time. This may expose
more NFS-only entries and/or FGN-patterned names. If so, repeat the
renaming and syncing process as needed.
Running Periodic Checks for NFS-Only Entries
Best practices dictate that you occasionally run an inconsistencies report on
your multi-protocol volumes to monitor for NFS-only entries. Clients can
create these by using bad characters in file/directory names, making a pair of
entries with a case-collision, or by making an entry name that happens to
match an FGN on one of the volume’s back-end filers. As described above,
once a directory contains any NFS-only or FGN-patterned entry, it performs
extra processing for certain (rare) client operations.
CLI Maintenance Guide
10 - 71
Chapter 10
Troubleshooting Managed Volumes
Migrations in a Multi-Protocol Namespace
Migrations in a multi-protocol (NFS and CIFS) volume have subtle side
effects. These side effects compensate for limitations in back-end filers;
clients are unaffected in most cases, but this section is offered so that you
are aware of any potential issues.
Skip to the next section if your namespace is CIFS-only or NFS-only.
File-Attribute Migrations
All file migrations are concerned with file attributes in addition to the files
themselves. File attributes are permission settings, the name or ID of the
user who owns the file, the group or groups who have access to the file,
last-modified times, named streams, and other external data associated with
the file. File-attribute migrations require special semantics in a
multi-protocol namespace (that is, a namespace whose shares support both
NFS and CIFS access). If your namespace is NFS-only or CIFS-only, you
can skip this section.
A multi-protocol namespace can be backed by a heterogeneous mix of
multi-protocol filers (MPFs), possibly from multiple vendors. The ARX
passes client requests to these filers, and passes filer responses back to the
clients. File attributes, such as file ownership and permission settings, are
managed by each filer.
NFS and CIFS have fundamentally different file attributes, and each MPF
vendor has unique semantics for reconciling the two. An NFS client can
change a file’s attributes on Filer X, and Filer X uses its semantics to change
the CIFS attributes accordingly. This translation is manifestly inexact, so an
MPF from another vendor typically gets a slightly different CIFS translation
for the same NFS attributes.
If the ARX migrates the filer from Filer X to Filer Y (made by two different
vendors), it takes these different semantics into account. This ensures that
the NFS and CIFS file attributes are preserved as much as possible as they
are migrated from one vendor to another. In some cases, file attributes are
interpreted differently on the destination filer. The sections below share the
details of attribute migration.
Use these tables along with vendor documentation to determine any
implications for your clients.
10 - 72
Migrations in a Multi-Protocol Namespace
From a NetApp Filer, UNIX Qtree
The following table shows how file attributes are migrated from a NetApp
filer with a UNIX-based Qtree:
NFS
Vendor for Destination
Filer
NetApp, UNIX Qtree
NetApp, UNIX Qtree with
cifs.preserve_unix_security
Permission Bits
copied, then reset
after file is transferred
through CIFS
CIFS
UID, GID, time
stamps, ...
copied
DOS Attributes
Security
Descriptor (SD)
copied (as dictated
by destination
Qtree)
derived by
destination
(NetApp) filer
NetApp, NTFS Qtree
Migrates between these two types of Qtrees are not supported.
Samba
copied
not copied
EMC
all copied after SD
derived by NetApp, then copied
(overriding any volume ACLs)
EMC, MIXED
From a NetApp Filer, UNIX Qtree with cifs.preserve_unix_security
NetApp’s cifs.preserve_unix_security flag causes a NetApp volume to
mimic its NFS file permissions with a special CIFS ACL. This special ACL
is ignored when migrated to most filers, but it requires some special
treatment when migrated from one NetApp volume to another. The
following table shows how file attributes are migrated from a NetApp filer
with a UNIX-based Qtree and this special attribute:
NFS
Vendor for Destination
Filer
Permission Bits
CIFS
UID, GID, time
stamps, ...
copied
DOS Attributes
Security
Descriptor (SD)
copied (as dictated
by destination
Qtree)
derived by
destination
(NetApp) filer
NetApp, UNIX Qtree
copied, then reset
after file is transferred
through CIFS
NetApp, UNIX Qtree with
cifs.preserve_unix_security
copied
NetApp, NTFS Qtree
Migrates between these two types of Qtrees are not supported.
Samba
copied
not copied
EMC
all copied after SD
derived by NetApp, then copied
(overriding any volume ACLs)
copied after UNIX
attributes
EMC, MIXED
CLI Maintenance Guide
10 - 73
Chapter 10
Troubleshooting Managed Volumes
From a NetApp Filer, NTFS Qtree
The following table shows how file attributes are migrated from a NetApp
filer with an NTFS-based Qtree:
NFS
CIFS
Vendor for Destination
Filer
Permission Bits
UID, GID, time
stamps, ...
NetApp, UNIX Qtree
Migrates between NTFS and UNIX Qtrees are not supported.
DOS Attributes
Security
Descriptor (SD)
NetApp, UNIX Qtree with
cifs.preserve_unix_security
copied
NetApp, NTFS Qtree
only high (setuid, setgid, and sticky) bits
copied; remaining attributes derived by
destination (NetApp) filer.
Samba
Migrates from NetApp/NTFS to Samba (no ACLs) are not supported.
EMC
copied, then reapplied after SD
copied after initial copy of UNIX
attributes
EMC, MIXED
copied
copied after UNIX attributes
From an EMC File Server (MIXED or not)
The following table shows how file attributes are migrated from an EMC
file server. These rules apply whether or not the source-EMC file server is
MIXED mode (that is, whether or not the source file system has its
“accesspolicy” set to “MIXED”):
NFS
Vendor for Destination
Filer
Permission Bits
NetApp, UNIX Qtree
CIFS
UID, GID, time
stamps, ...
DOS Attributes
Security
Descriptor (SD)
copied
copied (as dictated
by destination
Qtree)
derived by
destination
(NetApp) filer
NetApp, NTFS Qtree
only high (setuid, setgid, and sticky) bits
copied; remaining attributes derived by
destination (NetApp) filer.
copied after initial copy of UNIX high bits
Samba
copied
derived by destination (Samba) filer
EMC
copied
copied after UNIX attributes
NetApp, UNIX Qtree with
cifs.preserve_unix_security
EMC, MIXED
10 - 74
Migrations in a Multi-Protocol Namespace
From a Unix Filer with Samba
The following table shows how file attributes are migrated from an Samba
filer that does not support CIFS ACLs:
NFS
Vendor for Destination
Filer
Permission Bits
NetApp, UNIX Qtree
copied
CIFS
UID, GID, time
stamps, ...
NetApp, UNIX Qtree with
cifs.preserve_unix_security
DOS Attributes
Security
Descriptor (SD)
copied (as dictated
by destination
Qtree)
derived by
destination
(NetApp) filer
NetApp, NTFS Qtree
Migrates from Samba (no ACLs) to NetApp/NTFS are not supported.
Samba
copied
derived by destination (Samba) filer
EMC
copied
derived by destination (EMC) filer
EMC, MIXED
copied, then reapplied after the file is
transferred through CIFS
not copied; derived by destination
(EMC) filer
CLI Maintenance Guide
10 - 75
Chapter 10
Troubleshooting Managed Volumes
Showing Policy History for a Volume
From any mode, you can use the show policy history command to show all of
the policy transactions for a given managed volume:
show policy history namespace namespace volume vol‐path
where
namespace (1-30 characters) is the namespace, and
vol-path (1-1024 characters) identifies the volume to examine.
The output lists all policy-related events that occurred in the volume, in
chronological order. For example, the following command sequence shows
the policy history for the “wwmed~/acct” volume:
bstnA(gbl)# show policy history namespace wwmed volume /acct
Namespace: wwmed
Volume: /acct
Rule
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
/acct
Time Message
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2012‐03‐26T04:51:49 Rule [wwmed:/acct:docs2das8]: Created.
2012‐03‐26T04:51:49 Rule [wwmed:/acct:docs2das8]: Enabled.
2012‐03‐26T04:51:50 Rule [wwmed:/acct:fm1]: Created.
2012‐03‐26T04:51:50 The configuration change conflicted with another change. The operation will retry.
2012‐03‐26T04:51:51 Rule [wwmed:/acct:fm1]: Enabled.
2012‐03‐26T04:52:00 Rule [wwmed:/acct:fm1]: The initial scan has been disabled for this rule.
2012‐03‐26T04:52:04 Rule [wwmed:/acct:fm1]: The initial scan has been disabled for this rule.
Showing Detailed Status for a Particular Rule
If you add the name of a rule or share-farm, detailed status for the object
appears:
show policy history namespace namespace volume vol‐path rule rl‐name
where
namespace (1-30 characters) is the namespace,
vol-path (1-1024 characters) identifies the volume to examine, and
rl-name (1-1024 characters) is one rule or share farm.
The output shows detailed events for the given policy object. For example,
the following command sequence shows the policy history for the
“dos2das8” rule:
bstnA(gbl)# show policy history namespace wwmed volume /acct rule docs2das8
Namespace: wwmed
Volume: /acct
Rule
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
10 - 76
Showing Policy History for a Volume
docs2das8
Time Message
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2009‐04‐22T04:55:44 Enabled.
2009‐04‐22T04:56:01 Starting scan.
2009‐04‐22T04:56:04 Scan complete.
bstnA(gbl)# ...
This example shows the history for the “fm1” share farm in the same
volume:
bstnA(gbl)# show policy history namespace wwmed volume /acct rule fm1
Namespace: wwmed
Volume: /acct
Rule
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
fm1
Time Message
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2009‐04‐22T05:47:20 Enabled.
2009‐04‐22T05:47:53 The initial scan has been disabled for this rule.
bstnA(gbl)# ...
Showing Any or All Pending Migrations
Any files that are waiting to be migrated appear in the policy queue. Use the
show policy queue command to see if any migrations are pending:
show policy queue namespace namespace volume vol‐path
where
namespace (1-30 characters) is the namespace, and
vol-path (1-1024 characters) identifies the volume to examine.
The output shows a table with three rows per file. The first line has the
virtual-file path (starting with the managed-volume path). The second line
has the rule name and storage target. The third line summarizes the current
status of the migrated file. If files appear in the queue for long, the files may
be very large, or there may be a problem with the policy engine or filers.
For example, this shows several files in the migration queue:
bstnA# show policy queue namespace medarcv volume /rcrds
File
Rule Target
Status
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
/rcrds/2000/planA/fd_roosevelt.dat (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
/rcrds/2000/planA/jq_adams.dat (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
/rcrds/2000/planA/s_adams.dat (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
/rcrds/2000/planA/t_jefferson.dat (Migrate)
CLI Maintenance Guide
10 - 77
Chapter 10
Troubleshooting Managed Volumes
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
/rcrds/2000/planA/t_roosevelt.dat (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
/rcrds/2007/late_test_results./june.xls (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
bstnA# ...
Showing Auto-Closed Files (CIFS)
This section only applies to files and rules in a volume that supports CIFS.
You can configure a file-placement rule to automatically close any open
files and hold them closed until the file is migrated. This makes it possible
for the rule to migrate the file without interference from client writes. This
feature is discussed in of the Automatically Closing All Open Files (CIFS),
on page 14-14 of the ARX® CLI Storage-Management Guide.
To see all files that are currently held closed, add the auto-close option to
the end of the show policy queue command:
show policy queue namespace namespace volume vol‐path auto‐close
The output is the same as above, with additional lines for each file that the
volume is holding closed. For example:
bstnA# show policy queue namespace medarcv volume /rcrds auto‐close
File
Rule Target
Status
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
/rcrds/flu_vaccine.list (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled)
/rcrds/gw_medical_record.dat (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
/rcrds/hst_medical_record.dat (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled)
/rcrds/kmo_medical_record.dat (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
/rcrds/KMO_ME~1.DAT (Migrate)
dailyArchive bulk
In Progress (Auto‐Close Enabled) (Client Access Denied)
bstnA# ...
Canceling All Pending Migrations
To cancel a volume’s pending migrations, go to priv-exec mode and use the
cancel migration command:
cancel migration namespace volume vol‐path
where
namespace (1-30 characters) identifies the namespace, and
10 - 78
Showing Policy History for a Volume
vol-path (1-1024 characters) is the managed volume with pending
migrations.
A prompt requests confirmation before the CLI cancels the migrations; enter
yes to confirm.
For example, this command cancels all queued migrations in the
“insur~/claims” volume:
bstnA(gbl)# end
bstnA# cancel migration insur volume /claims
Are you sure you want to cancel all the queued migrates in volume '/claims'? [yes/no] yes
bstnA# ...
Canceling the Migration of a Single File
You can identify a single file to cancel its migration:
cancel migration file file‐name
where file-name (1-1024 characters) is a full virtual path to the file,
including the path name of the managed volume that contains it. This is
the file path that clients see.
Unlike the command to stop all migrations in a volume, this does not prompt
for confirmation.
For example, this command cancels the migration for a single file:
bstnA(gbl)# end
bstnA# cancel migration file /claims/y2kclaims/artwork/bigpict.tif
bstnA# ...
CLI Maintenance Guide
10 - 79
Chapter 10
Troubleshooting Managed Volumes
Addressing Inconsistent Directory Attributes
Directory attributes, such as access privileges, can become inconsistent in a
namespace if those attributes are changed on the filer directly, outside of the
control of the ARX. Directory attributes can become inconsistent also in
special cases in which the actual disk on a filer is full, or when a quota for
disk capacity usage by a specific user is met, and there is not enough space
available on the disk to update the directory attribute.
In most cases, the ARX will recognize and address any inconsistencies that
it encounters transparently, without any need for intervention by the user.
However, in cases in which attributes have been made to be inconsistent by
changes outside of the ARX, it may be expedient to address those
inconsistencies explicitly. Mostly, this section describes the procedures that
are available for use in the case of attributes having been changed outside of
the ARX’s management.
It is not necessary for directory attributes to be consistent across all striped
directories. When a backout is unsuccessful or is not possible, the system
continues to operate with inconsistent attributes and continues to provide
access to the directory. Full access to a directory is restored automatically
when an out-of-space condition is removed, without any administrative
action executed on the ARX.
Metadata Inconsistencies
In addition to quota and disk space issues, metadata inconsistencies can
occur in multiprotocol volumes in which both CIFS and NFS are used. In
this case, inconsistencies can occur without being caused by the client; for
example, a file name or directory name simply may be different between
CIFS and NFS.
The nsck report metadata-only command displays the metadata for a
specified namespace or volume. The resulting reports include information
about directories with inconsistent attributes, if any are found. A directory is
flagged as having inconsistent attributes when a discrepancy is identified in
the attributes between a master directory and one or more of its stripes.
Attribute Inconsistency Use Cases
Attribute inconsistency encompasses two distinct use cases:
• Attributes becoming inconsistent as a result of storage depletion.
• Attributes becoming inconsistent because file attributes were changed
explicitly outside of the ARX’s management.
In most cases, the ARX will recognize and address any inconsistencies that
it encounters transparently, without any need for intervention by the user.
This section mostly describes the procedures that are available for use in the
case of attributes having been changed outside of the ARX’s management.
10 - 80
Addressing Inconsistent Directory Attributes
Finding and Showing Inconsistent Attributes
If inconsistent directory attributes are present in a particular namespace,
they will be visible in the contents of namespace check (nsck) reports that
are executed against that namespace.
Finding Attribute Inconsistencies
The nsck... report inconsistencies command compares the attributes of
the master directory to the attributes of each secondary directory and reports
any discrepancies.
There are three types of inconsistency that can be reported for directories;
one is for secondary directory attributes, and the other two are for directory
metadata:
• IS – The IS inconsistency type is reported for any secondary directory for
which the attributes do not match the attributes of the master directory.
The inconsistency is reported only for filer shares that have been detected
as storing all security descriptor information.
• MI – The MI inconsistency type is reported on any master directory that
is marked with the inconsistent attribute flag, but where no shares are
detected as inconsistent.
• SI – The SI inconsistency type is reported on any master directory that is
not marked with the inconsistent attribute flag, but where the shares are
detected as inconsistent. This inconsistency will be reported only for
secondary directories that have been detected as storing all security
descriptor information.
A brief description of each of these types is included in the report’s legend.
The nsck... report inconsistencies command also compares the state of
striped directory attributes to the inconsistent-attributes flag in the metadata.
Any discrepancies that are found are reported.
Synchronizing Directory Attributes
The synchronization process checks stripe directory attributes, reports
inconsistencies found, synchronizes directory attributes, and corrects
metadata as necessary.
Use the nsck... sync directories command to synchronize inconsistency
directory attributes.
The synchronization process identifies a number of different cases of
attribute inconsistency and reports them if they’re present:
• IS – striped directory attributes inconsistent.
• SS – striped directory attributes synchronized.
• IA – inconsistent attributes.
• CA – consistent attributes.
• SY – directory metadata synchronized.
CLI Maintenance Guide
10 - 81
Chapter 10
Troubleshooting Managed Volumes
Resolving Directory Attribute Inconsistency
Each time that a directory is accessed, the ARX software attempts to
re-synchronize the directory attributes. This will fail as long as the filer
reports that it is out of disk space. The inconsistent attributes can be cleared
using one of these methods:
• reducing the disk usage
• increasing the disk space
Disk usage can be reduced either by removing files that reside on the full
filer share, or by migrating them to another filer share in the volume. The
SNMP trap that is sent when directory attributes are found to be inconsistent
contains the information necessary for identifying which file system needs
attention.
Increasing disk space can be performed only by the filer administrator, but
modifying quotas or resizing file systems can be performed by other
authorized users.
File removal is performed by the end user, through the management
interface.
File migration can be performed by an administrator by modifying policy
rules to place less data on full filer shares, or a user can change the time
stamps on a file to cause a migration rule to move it to a different tier. Linux
and UNIX users can use the standard shell command "touch" to accomplish
this. Windows Explorer and Windows command line interfaces do not offer
direct ways of manipulating file time stamps, but there is a "touch"
command available in Windows Services for UNIX and Subsystem for
UNIX Applications. Alternatively, the following command, executed at a
command prompt, emulates the "touch" command:
copy /b filename +’’
Per Operation Restriction Summary
Operations that can affect the consistency of a directory structure across filer
shares cannot be allowed, and are restricted. Operations that could
potentially grant access to file data in violation of the desired directory
attributes also are disallowed.
Note the following operation restrictions:
• For files:
10 - 82
•
Open-file is always allowed, since access is controlled
primarily by the object permissions, not by the parent directory
permissions.
•
Get-attributes is always allowed. Directory attributes are
always returned from the directory master, and are always
correct. File attributes are returned from the file, which is
always correct.
•
Set-attributes on a file is unrestricted.
Addressing Inconsistent Directory Attributes
•
If a set-attributes operation is attempted on a directory that is
marked as inconsistent-attributes, the operation is refused with
a disk-full error.
•
Create-file is allowed if the target share is on the same filer
share as the master directory of the parent directory, since the
inherited attributes and permission checking will be correct.
bstnA(gbl)#All other cases of create-file will be refused with a
disk-full error.
•
Remove-file is allowed if the file is on the same filer share as
the master of the parent directory. Otherwise, it will fail with
an access-denied error.
•
The set-file-info request to set the disposition flag to
delete-on-close is treated identically to the remove-file
operation.
•
If either the source or destination directory of a rename-file or
remake-directory operation is marked as
inconsistent-attributes, the operation is refused with a disk-full
error.
• For directories:
CLI Maintenance Guide
•
Readdir (find-files in CIFS) is always allowed.
•
Create-directory is allowed if the target filer share is the same
filer share as the directory master of the parent directory. All
other cases of create-directory will be refused with a disk-full
error.
•
Remove-directory is allowed if the directory master is located
on the same filer share as the parent directory master.
10 - 83
Chapter 10
Troubleshooting Managed Volumes
10 - 84
11
Troubleshooting CIFS Services
• Overview
• Showing Client-Connection Statistics
• Showing Client Sessions
• Dropping a CIFS Client
• Listing Open Files in a CIFS Service
• Closing an Open File
• Listing Kerberos Tickets Granted to Clients
• Leaving and Rejoining an AD Domain
Overview
Overview
This chapter describes how to run various show commands that monitor
client traffic to a front-end CIFS service. It also contains commands to break
a CIFS-client connection or close an open file. This extends the previous
chapters, which described tools for collecting diagnostic information and
troubleshooting network connections.
Showing Client-Connection Statistics
A CIFS service keeps client-access statistics for each of its exports/shares.
Use the show cifs-service exports command to show these statistics:
show cifs‐service exports {fqdn | all}
where fqdn | all is a required choice:
fqdn (1-128 characters) identifies a single CIFS service by its
fully-qualified domain name (for example, www.myorg.org).
all selects all CIFS services on the current switch.
Each NSM processor exports all of the exports/shares from a CIFS service.
The output from this command therefore contains a set of rows for each
processor, one per export/share. Each row describes the processor and
export, and shows the statistics for client connections to that export on that
processor.
For example, this shows all client connections to the CIFS service at
“ac1.medarch.org:”
bstnA> show cifs‐service exports ac1.medarch.org
Global Server: ac1.MEDARCH.ORG [192.168.25.15]
Namespace Tree Connects
Proc Export Virtual Path Curr Peak Total
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐
2.5 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.5 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
2.5 acopia#ns4_claims$ insur 0 0 0
/claims
2.5 ARCHIVES medarcv 0 0 0
/rcrds
2.5 bulkstorage medarcv 0 0 0
/rcrds
2.5 CELEBS medarcv 0 0 0
/rcrds/VIP_wing
2.5 chem_results medarcv 0 0 0
/test_results
2.5 CLAIMS insur 0 0 0
/claims
2.5 E$ medarcv 0 0 0
/acopia$ns3
CLI Maintenance Guide
11 - 3
Chapter 11
Troubleshooting CIFS Services
2.5 F$ insur 0 0 0
/acopia$ns4
2.5 labs medarcv 0 0 0
/lab_equipment
2.5 MP3S medarcv 0 0 0
/rcrds/2011/mp3downloads
2.5 SPECS insur 0 0 0
/claims/specs
2.5 STATS insur 0 0 0
/claims/stats
2.5 xraysScanners medarcv 0 0 0
/lab_equipment
2.5 Y2004 medarcv 0 0 0
/rcrds/2004
2.5 Y2005 medarcv 0 0 0
/rcrds/2005
2.5 Y2010 medarcv 0 0 0
/rcrds/2010
2.5 Z$ medarcv 0 0 0
/test_results
2.6 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.6 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
2.6 acopia#ns4_claims$ insur 0 0 0
/claims
2.6 ARCHIVES medarcv 0 0 0
/rcrds
2.6 bulkstorage medarcv 0 0 0
/rcrds
2.6 CELEBS medarcv 0 0 0
/rcrds/VIP_wing
2.6 chem_results medarcv 0 0 0
/test_results
2.6 CLAIMS insur 0 0 0
/claims
2.6 E$ medarcv 0 0 0
/acopia$ns3
2.6 F$ insur 0 0 0
/acopia$ns4
2.6 labs medarcv 0 0 0
/lab_equipment
2.6 MP3S medarcv 0 0 0
/rcrds/2011/mp3downloads
2.6 SPECS insur 0 0 0
/claims/specs
2.6 STATS insur 0 0 0
/claims/stats
2.6 xraysScanners medarcv 0 0 0
/lab_equipment
2.6 Y2004 medarcv 0 0 0
/rcrds/2004
2.6 Y2005 medarcv 0 0 0
/rcrds/2005
2.6 Y2010 medarcv 0 0 0
/rcrds/2010
2.6 Z$ medarcv 0 0 0
/test_results
2.7 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.7 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
11 - 4
Showing Client-Connection Statistics
2.7 acopia#ns4_claims$ insur 0 0 0
/claims
2.7 ARCHIVES medarcv 0 0 0
/rcrds
2.7 bulkstorage medarcv 0 0 0
/rcrds
2.7 CELEBS medarcv 0 1 4
/rcrds/VIP_wing
2.7 chem_results medarcv 0 0 0
/test_results
2.7 CLAIMS insur 0 0 0
/claims
2.7 E$ medarcv 0 0 0
/acopia$ns3
2.7 F$ insur 0 0 0
/acopia$ns4
2.7 labs medarcv 0 1 1
/lab_equipment
2.7 MP3S medarcv 0 0 0
/rcrds/2011/mp3downloads
2.7 SPECS insur 0 0 0
/claims/specs
2.7 STATS insur 0 0 0
/claims/stats
2.7 xraysScanners medarcv 0 0 0
/lab_equipment
2.7 Y2004 medarcv 0 0 0
/rcrds/2004
2.7 Y2005 medarcv 0 0 0
/rcrds/2005
2.7 Y2010 medarcv 0 0 0
/rcrds/2010
2.7 Z$ medarcv 0 0 0
/test_results
2.8 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.8 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
2.8 acopia#ns4_claims$ insur 0 0 0
/claims
2.8 ARCHIVES medarcv 0 0 0
/rcrds
2.8 bulkstorage medarcv 0 0 0
/rcrds
2.8 CELEBS medarcv 0 0 0
/rcrds/VIP_wing
2.8 chem_results medarcv 0 0 0
/test_results
2.8 CLAIMS insur 0 0 0
/claims
2.8 E$ medarcv 0 0 0
/acopia$ns3
2.8 F$ insur 0 0 0
/acopia$ns4
2.8 labs medarcv 0 0 0
/lab_equipment
2.8 MP3S medarcv 0 0 0
/rcrds/2011/mp3downloads
2.8 SPECS insur 0 0 0
/claims/specs
2.8 STATS insur 0 0 0
/claims/stats
CLI Maintenance Guide
11 - 5
Chapter 11
Troubleshooting CIFS Services
2.8 xraysScanners medarcv 0 0 0
/lab_equipment
2.8 Y2004 medarcv 1 1 3
/rcrds/2004
2.8 Y2005 medarcv 0 0 0
/rcrds/2005
2.8 Y2010 medarcv 0 0 0
/rcrds/2010
2.8 Z$ medarcv 0 0 0
/test_results
2.9 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.9 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
2.9 acopia#ns4_claims$ insur 0 0 0
/claims
2.9 ARCHIVES medarcv 0 1 6
/rcrds
2.9 bulkstorage medarcv 0 0 0
/rcrds
2.9 CELEBS medarcv 0 0 0
/rcrds/VIP_wing
2.9 chem_results medarcv 0 0 0
/test_results
2.9 CLAIMS insur 0 0 0
/claims
2.9 E$ medarcv 0 0 0
/acopia$ns3
2.9 F$ insur 0 0 0
/acopia$ns4
2.9 labs medarcv 0 0 0
/lab_equipment
2.9 MP3S medarcv 1 1 3
/rcrds/2011/mp3downloads
2.9 SPECS insur 0 0 0
/claims/specs
2.9 STATS insur 0 0 0
/claims/stats
2.9 xraysScanners medarcv 0 0 0
/lab_equipment
2.9 Y2004 medarcv 0 0 0
/rcrds/2004
2.9 Y2005 medarcv 1 1 2
/rcrds/2005
2.9 Y2010 medarcv 0 0 0
/rcrds/2010
2.9 Z$ medarcv 0 0 0
/test_results
2.10 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.10 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
2.10 acopia#ns4_claims$ insur 0 0 0
/claims
2.10 ARCHIVES medarcv 1 1 2
/rcrds
2.10 bulkstorage medarcv 0 0 0
/rcrds
2.10 CELEBS medarcv 0 0 0
/rcrds/VIP_wing
2.10 chem_results medarcv 0 0 0
/test_results
11 - 6
Showing Client-Connection Statistics
2.10 CLAIMS insur 0 0 0
/claims
2.10 E$ medarcv 0 0 0
/acopia$ns3
2.10 F$ insur 0 0 0
/acopia$ns4
2.10 labs medarcv 0 0 0
/lab_equipment
2.10 MP3S medarcv 0 0 0
/rcrds/2011/mp3downloads
2.10 SPECS insur 0 0 0
/claims/specs
2.10 STATS insur 0 0 0
/claims/stats
2.10 xraysScanners medarcv 0 0 0
/lab_equipment
2.10 Y2004 medarcv 0 0 0
/rcrds/2004
2.10 Y2005 medarcv 0 0 0
/rcrds/2005
2.10 Y2010 medarcv 0 0 0
/rcrds/2010
2.10 Z$ medarcv 0 0 0
/test_results
2.11 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.11 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
2.11 acopia#ns4_claims$ insur 0 0 0
/claims
2.11 ARCHIVES medarcv 0 0 0
/rcrds
2.11 bulkstorage medarcv 0 0 0
/rcrds
2.11 CELEBS medarcv 0 0 0
/rcrds/VIP_wing
2.11 chem_results medarcv 0 0 0
/test_results
2.11 CLAIMS insur 0 0 0
/claims
2.11 E$ medarcv 0 0 0
/acopia$ns3
2.11 F$ insur 0 0 0
/acopia$ns4
2.11 labs medarcv 0 0 0
/lab_equipment
2.11 MP3S medarcv 0 0 0
/rcrds/2011/mp3downloads
2.11 SPECS insur 0 0 0
/claims/specs
2.11 STATS insur 0 0 0
/claims/stats
2.11 xraysScanners medarcv 0 0 0
/lab_equipment
2.11 Y2004 medarcv 0 0 0
/rcrds/2004
2.11 Y2005 medarcv 0 0 0
/rcrds/2005
2.11 Y2010 medarcv 0 0 0
/rcrds/2010
2.11 Z$ medarcv 0 0 0
/test_results
CLI Maintenance Guide
11 - 7
Chapter 11
Troubleshooting CIFS Services
2.12 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.12 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
2.12 acopia#ns4_claims$ insur 0 0 0
/claims
2.12 ARCHIVES medarcv 0 0 0
/rcrds
2.12 bulkstorage medarcv 0 0 0
/rcrds
2.12 CELEBS medarcv 0 0 0
/rcrds/VIP_wing
2.12 chem_results medarcv 0 0 0
/test_results
2.12 CLAIMS insur 0 1 1
/claims
2.12 E$ medarcv 0 0 0
/acopia$ns3
2.12 F$ insur 0 0 0
/acopia$ns4
2.12 labs medarcv 0 0 0
/lab_equipment
2.12 MP3S medarcv 0 0 0
/rcrds/2011/mp3downloads
2.12 SPECS insur 0 0 0
/claims/specs
2.12 STATS insur 0 0 0
/claims/stats
2.12 xraysScanners medarcv 0 0 0
/lab_equipment
2.12 Y2004 medarcv 0 0 0
/rcrds/2004
2.12 Y2005 medarcv 0 0 0
/rcrds/2005
2.12 Y2010 medarcv 0 0 0
/rcrds/2010
2.12 Z$ medarcv 0 0 0
/test_results
‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐
Totals: 4 8 22
bstnA> ...
Showing Statistics from One NSM Processor
Each CIFS-client connection is managed by one NSM processor. If you
show the connection statistics for a single CIFS service (as shown above),
you can narrow the focus further to a single NSM processor. To accomplish
this, identify the processor after the FQDN:
show cifs‐service exports fqdn slot.processor
where
fqdn (1-128 characters) identifies the CIFS service,
slot (2 in the ARX-4000, 1 in all other platforms) is the slot number
of the desired NSM, and
11 - 8
Showing Client-Connection Statistics
processor (1-12) is the NSM-processor number. Use show
processors for a complete list of processors (and their modules and
slots) on the ARX.
The output is formatted the same way as shown above. For example, this
shows the connection statistics for the “ac1.medarch.org” service at
processor 2.5:
bstnA> show cifs‐service exports ac1.medarch.org 2.5
Global Server: ac1.MEDARCH.ORG [192.168.25.15]
Namespace Tree Connects
Proc Export Virtual Path Curr Peak Total
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐
2.5 acopia#ns3_lab_equipment$ medarcv 0 0 0
/lab_equipment
2.5 acopia#ns3_rcrds$ medarcv 0 0 0
/rcrds
2.5 acopia#ns4_claims$ insur 0 0 0
/claims
2.5 ARCHIVES medarcv 0 0 0
/rcrds
2.5 bulkstorage medarcv 0 0 0
/rcrds
2.5 CELEBS medarcv 0 0 0
/rcrds/VIP_wing
2.5 chem_results medarcv 0 0 0
/test_results
2.5 CLAIMS insur 0 0 0
/claims
2.5 E$ medarcv 0 0 0
/acopia$ns3
2.5 F$ insur 0 0 0
/acopia$ns4
2.5 labs medarcv 0 0 0
/lab_equipment
2.5 MP3S medarcv 0 0 0
/rcrds/2011/mp3downloads
2.5 SPECS insur 0 0 0
/claims/specs
2.5 STATS insur 0 0 0
/claims/stats
2.5 xraysScanners medarcv 0 0 0
/lab_equipment
2.5 Y2004 medarcv 0 0 0
/rcrds/2004
2.5 Y2005 medarcv 0 0 0
/rcrds/2005
2.5 Y2010 medarcv 0 0 0
/rcrds/2010
2.5 Z$ medarcv 0 0 0
/test_results
‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐
Totals: 0 0 0
CLI Maintenance Guide
11 - 9
Chapter 11
Troubleshooting CIFS Services
Showing Client Sessions
If MMC is allowed for this CIFS service (see Supporting MMC Browsing,
on page 11-23 of the ARX® CLI Storage-Management Guide), authorized
clients can use MMC to list all client connections to the CIFS service. You
can perform the same operation from the CLI. Use the show cifs-service
user-sessions command to list the client connections to one or all CIFS
services:
show cifs‐service user‐sessions {fqdn | all}
where fqdn | all is a required choice:
fqdn (1-128 characters) identifies a single CIFS service by its
fully-qualified domain name (for example, www.company.com).
all selects all CIFS services on the current switch.
The output is a table with one row per client session. Each row shows the
NSM processor to which the client is connected, the client’s IP address and
username, the authentication method that the client used, the age of the
connection (in seconds), and the front-end service to which they connected.
For example, this finds four client sessions for all CIFS services on the
switch:
bstnA# show cifs‐service user‐sessions all
CIFS Service ac1.MEDARCH.ORG Proc IP Address Auth Sign Age Username
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2.7 172.16.100.20 Kerberos Yes 00:00:33 Administrator@MEDARCH.ORG 2.7 172.16.100.20 NTLM Yes 00:00:41 juser@MEDARCH.ORG 2.9 172.16.100.68 Kerberos Yes 00:12:28 lfine_md@MEDARCH.ORG 2.9 172.16.100.68 NTLM Yes 00:12:35 lfine_md@MEDARCH.ORG 2.10 172.16.100.209 Kerberos Yes 00:00:38 choward_md@MEDARCH.ORG 2.10 172.16.100.209 NTLM Yes 00:12:36 choward_md@MEDARCH.ORG Total number of users displayed is 6
bstnA#
Showing Client Sessions at One NSM Processor
Each CIFS-client session is managed by one NSM processor. If you show
the connections to a single CIFS service (as shown above), you can narrow
the focus further to a single NSM processor. To accomplish this, identify the
processor after the FQDN:
show cifs‐service user‐sessions fqdn slot.processor
where
fqdn (1-128 characters) identifies a single CIFS service,
11 - 10
Showing Client Sessions
slot (2 on the ARX-4000, 1 in all other platforms) is the slot
number of the desired NSM, and
processor (1-12) is the NSM-processor number. Use show
processors for a complete list of processors (and their modules and
slots) on the ARX.
The output is formatted the same way as shown above.
For example, this shows the session hosted by the “ac1.medarch.org”
service at NSM processor 2.7:
bstnA> show cifs‐service user‐sessions ac1.medarch.org 2.7
CIFS Service ac1.MEDARCH.ORG Proc IP Address Auth Sign Age Username
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2.7 172.16.100.20 Kerberos Yes 00:00:27 Administrator@MEDARCH.ORG 2.7 172.16.100.20 NTLM Yes 00:00:35 juser@MEDARCH.ORG Total number of users displayed is 2
bstnA> ...
CLI Maintenance Guide
11 - 11
Chapter 11
Troubleshooting CIFS Services
Showing CIFS Work Queue Statistics
The show statistics cifs work-queues command enables you to display
time statistics for various CIFS-related tasks that transit the CIFS work
queues. These statistics are useful for diagnosing problems with CIFS
performance.
The command syntax is:
show statistics cifs work‐queues volume‐group vg‐id
or
show statistics cifs work‐queues instance instance‐id
where vg-id or instance-id specifies the volume group or namespace
instance identifier for which you want to display CIFS work queue statistics.
The command clear statistics cifs work-queues enables you to reset those
statistics. The clear statistics filer command resets some CIFS statistics that
are not covered by clear statistics cifs work-queues.
11 - 12
Showing CIFS Fastpath Statistics
Showing CIFS Fastpath Statistics
The command show statistics cifs fastpath enables you to display a
variety of statistics related to CIFS servers. These statistics include the
numbers of front end and back end connections, the number of transactions
handled, and others.
The command syntax is:
show statistics cifs fastpath [all | slot.processor]
where:
slot.processor indicates a specific NSM processor against which to execute
the command.
For example:
bstnA# show statistics cifs fastpath
Proc Transactions FrontEnd BackEnd File File
Handled Connections Connections Info Handles
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐‐‐
2.1 0 0 0 0 0
2.2 0 0 0 0 0
2.3 182 0 0 0 0
2.4 1840 6 0 0 0
2.5 128 1 0 0 0
2.6 0 0 0 0 0
2.7 71 2 2 0 0
2.8 46 1 2 0 0
2.9 97 2 4 0 0
2.10 44 1 2 0 0
2.11 0 0 0 0 0
2.12 27 0 0 0 0
bstnA#
CLI Maintenance Guide
11 - 13
Chapter 11
Troubleshooting CIFS Services
Dropping a CIFS Client
From priv-exec mode, you can use drop cifs-service user-session to close a
session with a CIFS client:
drop cifs‐service user‐session fqdn slot.processor ipaddress client
where
fqdn (1-128 characters) identifies a single CIFS service,
slot.processor identifies a network processor, and
client identifies the client session by its source-IP address.
A CLI prompt announces the results of the command.
For example, this command sequence shows all CIFS clients, drops a client
session, then shows that the session’s Age has restarted (indicating that the
client application re-connected to the CIFS service):
bstnA> show cifs‐service user‐sessions all
CIFS Service ac1.MEDARCH.ORG Proc IP Address Auth Sign Age Username
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2.7 172.16.100.20 Kerberos Yes 00:00:33 Administrator@MEDARCH.ORG 2.7 172.16.100.20 NTLM Yes 00:00:41 juser@MEDARCH.ORG 2.9 172.16.100.68 Kerberos Yes 00:12:28 lfine_md@MEDARCH.ORG 2.9 172.16.100.68 NTLM Yes 00:12:35 lfine_md@MEDARCH.ORG 2.10 172.16.100.209 Kerberos Yes 00:00:38 choward_md@MEDARCH.ORG 2.10 172.16.100.209 NTLM Yes 00:12:36 choward_md@MEDARCH.ORG Total number of users displayed is 6
bstnA> enable
bstnA# drop cifs‐service user‐session ac1.medarch.org 2.9 ipaddress 172.16.100.68
% INFO: All CIFS user sessions for the specified IP address were dropped.
bstnA# show cifs‐service user‐sessions all
CIFS Service ac1.MEDARCH.ORG Proc IP Address Auth Sign Age Username
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐ ‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
2.7 172.16.100.20 Kerberos Yes 00:00:33 Administrator@MEDARCH.ORG 2.7 172.16.100.20 NTLM Yes 00:00:41 juser@MEDARCH.ORG 2.9 172.16.100.68 Kerberos Yes 00:00:05 lfine_md@MEDARCH.ORG 2.9 172.16.100.68 NTLM Yes 00:00:05 lfine_md@MEDARCH.ORG 2.10 172.16.100.209 Kerberos Yes 00:00:38 choward_md@MEDARCH.ORG 2.10 172.16.100.209 NTLM Yes 00:12:36 choward_md@MEDARCH.ORG Total number of users displayed is 6
bstnA# ...
11 - 14
Listing Open Files in a CIFS Service
Listing Open Files in a CIFS Service
To list the files currently opened by CIFS clients, use the show cifs-service
open-files command:
show cifs‐service open‐files {fqdn | all}
where fqdn | all is a required choice:
fqdn (1-128 characters) is the fully-qualified domain name (for
example, www.company.com) for the CIFS service’s global server.
all selects all CIFS services on the current switch.
If remote-Windows management is allowed for this CIFS service (see
Supporting MMC Browsing, on page 11-23 of the ARX® CLI
Storage-Management Guide), authorized clients can use MMC to list these
files.
For each open file, this shows the NSM processor that is serving the file to
the client, the client’s IP address and identity, the “Virtual” IP address and
share that the client application sees, the filer’s IP address and share name,
the “Virtual” location of the file (from the client’s perspective), and the
location of the file from the filer’s perspective.
For example, this finds some files that are open in the CIFS service for
“ac1.medarch.org:”
bstnA> show cifs‐service open‐files ac1.medarch.org
Proc User IP Mode FID Virtual IP Virtual Share
User Name Locks Filer IP Filer Share
Virtual Path
Path on Filer
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐
2.2 172.16.100.209 Read+Write 513 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.20 histories
\rcrds\recoveryStats\examSchedule.doc
\recoveryStats\examSchedule.doc
2.2 172.16.100.209 Read+Write 514 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.29 prescriptions
\rcrds\recoveryStats\stdProcedure.doc
\recoveryStats\stdProcedure.doc
2.2 172.16.100.209 Read+Write 515 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.20 histories
\rcrds\recoveryStats\recoveryStats.xls
\recoveryStats\recoveryStats.xls
2.2 172.16.100.209 Read+Write 516 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.29 prescriptions
\rcrds\recoveryStats\memo.doc \recoveryStats\memo.doc 2.4 172.16.100.20 Read+Write 513 192.168.25.15 CELEBS
MEDARCH.ORG\juser 0 192.168.25.20 _acopia_CELEBS$_1$
\rcrds\VIP_wing\fractures\examSchedule.doc
\fractures\examSchedule.doc
CLI Maintenance Guide
11 - 15
Chapter 11
Troubleshooting CIFS Services
...
2.5 172.16.108.112 Read+Write 515 192.168.25.15 Y2004
MEDARCH.ORG\mhoward_md 0 192.168.25.29 Y2004
\rcrds\2004\recoveryStats\recoveryStats.xls
\recoveryStats\recoveryStats.xls
2.6 172.16.100.68 Read+Write 513 192.168.25.15 Y2005
MEDARCH.ORG\lfine_md 0 192.168.25.20 _acopia_Y2005_3$
\rcrds\2005\recoveryStats\examSchedule.doc
\recoveryStats\examSchedule.doc
2.6 172.16.100.68 Read+Write 514 192.168.25.15 Y2005
MEDARCH.ORG\lfine_md 0 192.168.25.29 Y2005
\rcrds\2005\recoveryStats\stdProcedure.doc
\recoveryStats\stdProcedure.doc
Total number of files displayed is 17
bstnA> ...
Focusing on One NSM Processor
As mentioned above, each CIFS session is managed by a single NSM
processor. If you show the open files at a single CIFS service, you can
further narrow the focus to a single NSM processor. To accomplish this,
identify the processor after the FQDN for the CIFS service:
show cifs‐service open‐files fqdn slot.processor
where
fqdn (1-128 characters) identifies a single CIFS service,
slot (2 on the ARX-4000, 1 in all other platforms) is the slot
number of the desired NSM, and
processor (1-12) is the NSM-processor number. Use show
processors for a complete list of processors (and their modules and
slots) on the ARX.
For example, this shows all open files hosted by the “ac1.medarch.org”
service at NSM processor 2.5:
bstnA> show cifs‐service open‐files ac1.medarch.org 2.5
Proc User IP Mode FID Virtual IP Virtual Share
User Name Locks Filer IP Filer Share
Virtual Path
Path on Filer
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐
2.5 172.16.108.112 Read+Write 513 192.168.25.15 Y2004
MEDARCH.ORG\mhoward_md 0 192.168.25.29 Y2004
\rcrds\2004\recoveryStats\examSchedule.doc
\recoveryStats\examSchedule.doc
2.5 172.16.108.112 Read+Write 514 192.168.25.15 Y2004
MEDARCH.ORG\mhoward_md 0 192.168.25.20 _acopia_Y2004_2$
\rcrds\2004\recoveryStats\stdProcedure.doc
\recoveryStats\stdProcedure.doc
11 - 16
Listing Open Files in a CIFS Service
2.5 172.16.108.112 Read+Write 515 192.168.25.15 Y2004
MEDARCH.ORG\mhoward_md 0 192.168.25.29 Y2004
\rcrds\2004\recoveryStats\recoveryStats.xls
\recoveryStats\recoveryStats.xls
Total number of files displayed is 3
bstnA> ...
CLI Maintenance Guide
11 - 17
Chapter 11
Troubleshooting CIFS Services
Closing an Open File
For situations where a client needs access to a long-opened file, you can use
the close cifs file command to forcibly close the file. Invoke this command
from priv-exec mode:
close cifs file fqdn slot.processor fid file‐id
where
fqdn (1-128 characters) identifies a single CIFS service,
slot.processor identifies a network processor, and
file-id (0-65535) identifies the file. This ID is shown in the output
of show cifs-service open-files, described above.
The CLI indicates a successful close by showing the processor and FID of
the closed file.
For example, this command sequence shows all open files hosted by the
“ac1.medarch.org” service at processor 2.2, closes one, and shows that the
file is no-longer open:
bstnA> show cifs‐service open‐files ac1.medarch.org 2.2
Proc User IP Mode FID Virtual IP Virtual Share
User Name Locks Filer IP Filer Share
Virtual Path
Path on Filer
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐
2.2 172.16.100.209 Read+Write 513 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.20 histories
\rcrds\recoveryStats\examSchedule.doc
\recoveryStats\examSchedule.doc
2.2 172.16.100.209 Read+Write 514 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.29 prescriptions
\rcrds\recoveryStats\stdProcedure.doc
\recoveryStats\stdProcedure.doc
2.2 172.16.100.209 Read+Write 515 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.20 histories
\rcrds\recoveryStats\recoveryStats.xls
\recoveryStats\recoveryStats.xls
2.2 172.16.100.209 Read+Write 516 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.29 prescriptions
\rcrds\recoveryStats\memo.doc \recoveryStats\memo.doc Total number of files displayed is 4
bstnA> enable
bstnA# close cifs file ac1.medarch.org 2.2 fid 515
slot:2.2 CIFS open file with FID:515 closed.
bstnA# show cifs‐service open‐files ac1.medarch.org 2.2
Proc User IP Mode FID Virtual IP Virtual Share
User Name Locks Filer IP Filer Share
Virtual Path
Path on Filer
11 - 18
Closing an Open File
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐
2.2 172.16.100.209 Read+Write 513 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.20 histories
\rcrds\recoveryStats\examSchedule.doc
\recoveryStats\examSchedule.doc
2.2 172.16.100.209 Read+Write 514 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.29 prescriptions
\rcrds\recoveryStats\stdProcedure.doc
\recoveryStats\stdProcedure.doc
2.2 172.16.100.209 Read+Write 516 192.168.25.15 ARCHIVES
MEDARCH.ORG\choward_md 0 192.168.25.29 prescriptions
\rcrds\recoveryStats\memo.doc \recoveryStats\memo.doc Total number of files displayed is 3
bstnA# ...
CLI Maintenance Guide
11 - 19
Chapter 11
Troubleshooting CIFS Services
Listing Kerberos Tickets Granted to Clients
If Kerberos is active for this CIFS service, the service passes Kerberos
tickets to clients who successfully authenticate. The CIFS service caches the
Kerberos tickets on behalf of its clients. These tickets have an expiration
time. To view all cached tickets, the clients who hold the tickets, and the
expiration times, use the show cifs-service kerberos-tickets command:
show cifs‐service kerberos‐tickets {fqdn | all}
where fqdn | all is a required choice:
fqdn (1-128 characters) is the fully-qualified domain name (for
example, www.company.com) for the CIFS service’s global server.
all selects all CIFS services on the current switch.
The output refers to a client as a Principal and a server or Ticket-Granting
Ticket as a Service Principal. For each principal with a Kerberos ticket, this
shows the contents of all tickets (including grant times and expiration
times). The total number of principals, ticket-granting tickets, and service
tickets appears at the end. If you select all, each CIFS service has a separate
section with the totals at the end.
For example, this finds that the “ac1.medarch.org” service has granted
tickets to two principals, “lfine_md@MEDARCH.ORG” and
“juser@MEDARCH.ORG:”
bstnA> show cifs‐service kerberos‐tickets ac1.medarch.org
Service: ac1.medarch.org
Start Time(UTC) Expiry Time(UTC) Service Principal
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Principal: lfine_md@MEDARCH.ORG 10/21/2009 06:08:18 PM 10/22/2009 04:08:18 AM krbtgt/MEDARCH.ORG@MEDARCH.ORG Renew Till: 10/28/2009 06:08:18 PM
Principal: juser@MEDARCH.ORG 10/21/2009 06:02:30 PM 10/22/2009 04:02:30 AM krbtgt/MEDARCH.ORG@MEDARCH.ORG Renew Till: 10/28/2009 06:02:30 PM
Total number of principals displayed is 2
Total number of ticket‐granting‐tickets cached for this selection is 2
Total number of service tickets cached for this selection is 0
bstnA> ...
Listing Tickets Granted to a Particular Principal
You can search for a particular principal by adding the user clause to the
end of the command:
show cifs‐service kerberos‐tickets {fqdn | all} user username
11 - 20
Listing Kerberos Tickets Granted to Clients
where username (1-128 characters) is a search string for one or more
principals. The output includes all principles whose first characters
match this string. This is a case-blind comparison, so “jpub” matches
“jpublic,” “jpublisher,” and “JPUBS.”
For example, this shows all tickets that “ac1.medarch.org” granted to any
principal whose name starts with “juser:”
bstnA> show cifs‐service kerberos‐tickets ac1.medarch.org user juser
Service: ac1.medarch.org
Start Time(UTC) Expiry Time(UTC) Service Principal
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Principal: juser@MEDARCH.ORG 10/21/2009 06:02:30 PM 10/22/2009 04:02:30 AM krbtgt/MEDARCH.ORG@MEDARCH.ORG Renew Till: 10/28/2009 06:02:30 PM
Total number of principals displayed is 1
Total number of ticket‐granting‐tickets cached for this selection is 1
Total number of service tickets cached for this selection is 0
bstnA> ...
CLI Maintenance Guide
11 - 21
Chapter 11
Troubleshooting CIFS Services
Leaving and Rejoining an AD Domain
Some AD policies set an expiration period for machine-account passwords;
if a CIFS service’s password expires, its clients can no longer use Kerberos
authentication. Before the password expires, you can use a CLI command to
reset it (see Changing the ARX’s Machine-Account Keys (Kerberos), on
page 11-38 of the ARX® CLI Storage-Management Guide). If a service’s
password expires before you reset it with that command, you must remove
and rebuild the CIFS-service configuration to get an entirely new machine
account password. The CIFS service cannot use its expired password to get
a new one.
Saving the CIFS-Service Configuration
You begin to remove a CIFS service by recording its configuration. Use the
show global-config cifs fqdn command for an ordered list of the CLI
commands required to build the fqdn service (recall Focusing On Named
Configurations, on page 5-15). For example, this shows the configuration
for the ac1.medarch.org service:
bstnA> show global‐config cifs ac1.medarch.org
;================================= cifs ==================================
cifs ac1.MEDARCH.ORG
description "insurance‐claim records"
kerberos‐creds ac1.MEDARCH.ORG MEDARCH.ORG eHaPWO/6TGWZdDtL15dstg== ac1$ HOST/ac1.MEDARCH.ORG 2
signatures
dynamic‐dns ac1
dynamic‐dns fs1
dynamic‐dns fs2
dynamic‐dns fs5
dynamic‐dns insur
browsing medarcv
browsing insur
export medarcv /rcrds as ARCHIVES description "2 year‐old medical records"
export medarcv /rcrds/2005 as Y2005 filer‐subshare
export medarcv /lab_equipment as labs description "lab equipment"
export medarcv /rcrds as bulkstorage description "big share, now merged thru ARX"
export medarcv /lab_equipment as xraysScanners description "scanners and xray machines"
export medarcv /test_results as chem_results description "chem‐lab records"
export medarcv /rcrds/VIP_wing as CELEBS filer‐subshare hidden
export medarcv /rcrds/2011/mp3downloads as MP3S filer‐subshare
export medarcv /rcrds/2004 as Y2004 filer‐subshare
export medarcv /rcrds/2010 as Y2010 filer‐subshare
export insur /claims as CLAIMS description "insurance claims"
export insur /claims/specs as SPECS
export insur /claims/stats as STATS description "claim stats"
enable
exit
bstnA> ...
Save this to a text file.
Remove the kerberos-creds command from the file. The CLI uses this
command only for global-config playback. That command preserves the
now-expired machine-account password, and precludes the domain-join
command that you must execute later.
11 - 22
Leaving and Rejoining an AD Domain
If there are any dynamic-dns commands, as above, remove all of them. If
there are more than one, you may want to save them to a separate file. Each
of these commands registers a DNS name with a dynamic-DNS server; this
is only possible after the CIFS service rejoins the domain.
Also remove the enable command. You enable the service manually, after
you rejoin the CIFS service to the AD domain.
For example, this is the correct configuration (without the kerberos-creds
command, the enable command, or any dynamic-dns commands) to store
for the above CIFS service:
cifs ac1.medarch.org
browsing medarcv
description "medical histories and records"
export medarcv /rcrds as ARCHIVES description "2 year‐old medical records"
export medarcv /rcrds/2005 as Y2005 filer‐subshare
export medarcv /lab_equipment as labs description "lab equipment"
export medarcv /rcrds as bulkstorage description "big share, now merged thru ARX"
export medarcv /lab_equipment as xraysScanners description "scanners and xray machines"
export medarcv /test_results as chem_results description "chem‐lab records"
export medarcv /rcrds/VIP_wing as CELEBS filer‐subshare hidden
export medarcv /rcrds/2004 as Y2004 filer‐subshare
exit
Dropping Terminal-Confirmation Prompts
At the ARX CLI, enter no terminal confirmation to avoid any confirmation
prompts. This makes it easier to copy and paste the above configuration into
the CLI later. You can enter this command from any mode. For example:
bstnA(gbl)# no terminal confirmation
bstnA(gbl)# ...
Clearing Dynamic-DNS Hostnames (If Necessary)
If the CIFS service uses dynamic DNS, you must remove the service’s
hostname(s) from your local DNS before you remove the service. This is
evident in the global-config file you created above; each dynamic-dns
command in the file (if there are any) represents one DNS hostname. You
can skip this section if your CIFS service does not use any dynamic-DNS
hostnames.
Use no dynamic dns for each of this service’s DNS hostnames. This sends
hostname-removal notifications to local dynamic-DNS servers (typically
DCs; see Removing a Host Name, on page 11-36 of the ARX® CLI
Storage-Management Guide). For each dynamic-dns command in the
global-config file, go to gbl-cifs mode and enter the no form of that exact
command. To continue the above example, this removes DNS support for
four hostnames:
bstnA(gbl)# cifs ac1.medarch.org
bstnA(gbl‐cifs[ac1.medarch.org])# no dynamic‐dns ac1
bstnA(gbl‐cifs[ac1.medarch.org])# no dynamic‐dns fs1
bstnA(gbl‐cifs[ac1.medarch.org])# no dynamic‐dns fs2
bstnA(gbl‐cifs[ac1.medarch.org])# no dynamic‐dns fs5
CLI Maintenance Guide
11 - 23
Chapter 11
Troubleshooting CIFS Services
bstnA(gbl‐cifs[ac1.medarch.org])# ...
Wait several seconds after you remove the final hostname, so that the DNS
server(s) have time to remove the hostname(s) from service. You can use the
show dynamic-dns command to monitor the operation (see Showing
Dynamic-DNS Status, on page 11-36 of the ARX® CLI
Storage-Management Guide).
Removing the CIFS Service
Once all dynamic-DNS hostnames are removed, you can remove the entire
CIFS service. Use the no cifs fqdn command from gbl mode (as described
in Removing a CIFS Service, on page 11-54 of the ARX® CLI
Storage-Management Guide). For example:
bstnA(gbl‐cifs[ac1.medarch.org])# exit
bstnA(gbl)# no cifs ac1.medarch.org
bstnA(gbl)# ...
Restoring the CIFS-Service Configuration
Add the service back by copying the configuration from the file above and
pasting it into the CLI. Remember to omit the kerberos-creds command.
For example:
bstnA(gbl)# cifs ac1.medarch.org
bstnA(gbl‐cifs[ac1.medarch.org])# browsing medarcv
bstnA(gbl‐cifs[ac1.medarch.org])# description "medical histories and records"
bstnA(gbl‐cifs[ac1.medarch.org])# export medarcv /rcrds as ARCHIVES description "2 year‐old medical records"
bstnA(gbl‐cifs[ac1.medarch.org])# export medarcv /rcrds/2005 as Y2005 filer‐subshare
bstnA(gbl‐cifs[ac1.medarch.org])# export medarcv /lab_equipment as labs description "lab equipment"
bstnA(gbl‐cifs[ac1.medarch.org])# export medarcv /rcrds as bulkstorage description "big share, now merged thru ARX"
bstnA(gbl‐cifs[ac1.medarch.org])# export medarcv /lab_equipment as xraysScanners description "scanners and xray machines"
bstnA(gbl‐cifs[ac1.medarch.org])# export medarcv /test_results as chem_results description "chem‐lab records"
bstnA(gbl‐cifs[ac1.medarch.org])# export medarcv /rcrds/VIP_wing as CELEBS filer‐subshare hidden
bstnA(gbl‐cifs[ac1.medarch.org])# export medarcv /rcrds/2004 as Y2004 filer‐subshare
bstnA(gbl‐cifs[ac1.medarch.org])# exit
bstnA(gbl)# ...
Rejoining the AD Domain and Enabling the Service
The next step is to rejoin the CIFS service to the AD domain. This generates
a new secret password for the CIFS service. Use the domain-join command
from gbl-cifs mode, as described in Joining a CIFS Service to an Active
Directory Domain, on page 11-26 of the ARX® CLI Storage-Management
Guide. Then use the enable command from the same mode. For example,
this joins the “ac1.medarch.org” service to its AD domain,
“MEDARCH.ORG:”
11 - 24
Leaving and Rejoining an AD Domain
bstnA(gbl)# cifs ac1.medarch.org
bstnA(gbl‐cifs[ac1.medarch.org])# domain‐join MEDARCH.ORG
Username: acoadmin
Password: ******
% INFO: Service 'ac1' successfully joined the domain using a pre‐created computer account.
% INFO: Service 'ac1' joined the domain with delegation type set to Unconstrained. The delegation of services on 'ac1' is allowed only with the Kerberos protocol.
bstnA(gbl‐cifs[ac1.medarch.org])# enable
bstnA(gbl‐cifs[ac1.medarch.org])# ...
After these commands, clients can use Kerberos to access the CIFS service.
Restoring Dynamic-DNS Hostnames (If Necessary)
If you removed any dynamic-DNS hostnames earlier, replay the
dynamic-dns commands now. For example, this restores four hostnames to
the “ac1.medarch.org” service:
bstnA(gbl)# cifs ac1.medarch.org
bstnA(gbl‐cifs[ac1.medarch.org])# dynamic‐dns ac1
bstnA(gbl‐cifs[ac1.medarch.org])# dynamic‐dns fs1
bstnA(gbl‐cifs[ac1.medarch.org])# dynamic‐dns fs2
bstnA(gbl‐cifs[ac1.medarch.org])# dynamic‐dns fs5
bstnA(gbl‐cifs[ac1.medarch.org])# ...
Turning Confirmation Prompts Back On
Best practices dictate that terminal confirmation is enabled for everyday
use of the CLI. As a final step, turn terminal confirmation back on. For
example:
bstnA(gbl‐cifs[ac1.medarch.org])# terminal confirmation
bstnA(gbl‐cifs[ac1.medarch.org])# ...
CLI Maintenance Guide
11 - 25
Chapter 11
Troubleshooting CIFS Services
Changing the Proxy User Password
For security reasons, you may choose to change the password for the proxy
user account from time to time. For a Windows proxy user, you must make
this change in two places: in Active Directory, where the corresponding
Windows user is defined, and in the ARX configuration.
Follow this procedure to make the change:
1. Change the password on the Domain Controller (DC).
2. Wait for all of the DCs in the proxy user’s Windows Domain to
synchronize their databases.
3. After the DCs are synchronized with the new password, re-run the
user (gbl-proxy-user) command to change the password on the
ARX.
During the time that the proxy-user password on the ARX does not match
the one in the external Active Directory, the volumes that use the proxy user
cannot access any of their back-end-CIFS storage. This prevents the
managed volumes from performing autonomous operations, such as
policy-driven migrations, and causes the CIFS shares to go offline. F5
recommends that you perform this procedure during non-busy hours.
11 - 26
12
GUI Maintenance
• Overview
• Removing the SSL Key
• Restarting the GUI
Overview
Overview
The GUI has an unsigned SSL key that it uses to authenticate with HTTPS
clients. This key is kept in a keystore file in the configs directory,
“acopia.keystore.” When your browser first connects to the GUI and
encounters this key, it issues a challenge similar to the following:
By clicking Yes, you accept the ARX’s SSL key. Your client then
recognizes the SSL key in future HTTPS connections.
The SSL key expires in one year. After the key expires, browsers warn that
the key has expired. Use the instructions in this chapter to regenerate the
SSL key.
Removing the SSL Key
The SSL key in stored in the “acopia.keystore” file in the configs directory.
You can use the show configs command to view the contents of the configs
directory, and you can use delete configs acopia.keystore to remove it. For
example:
bstnA# show configs
configs
acopia.keystore Aug 9 11:20 1.2 kB
active.license Sep 15 15:19 3.4 kB
api‐ssl.crt Aug 9 12:49 1009 B
api‐ssl.key Aug 9 12:49 891 B
arx.dossier Sep 15 15:19 3.0 kB
boot‐config Sep 16 00:46 1.5 kB
eeprom.dat Sep 16 00:13 119 B
encoded.license Sep 15 15:19 3.5 kB
nlad_smb.conf Sep 16 00:13 44 B
nlad.conf Sep 16 00:43 24 B
oem‐menu‐log.txt Sep 16 00:07 3.0 kB
omDbVersion.info Sep 16 00:11 280 B
startup‐config Sep 16 01:31 7.3 MB
unparsed.license Sep 15 15:19 3.4 kB
bstnA# delete configs acopia.keystore
bstnA# show configs
configs
CLI Maintenance Guide
12 - 3
Chapter 12
GUI Maintenance
boot‐config May 18 03:25 1.3k
omDbVersion.info May 18 03:00 279
running May 17 10:25 7.5k
startup‐config May 18 11:28 6.2M
bstnA# ...
12 - 4
Restarting the GUI
Restarting the GUI
You must stop and restart the GUI to create a new SSL key. You can
accomplish this by stopping any management access to HTTPS, then
re-opening access. Specifically, use the management access https command
to work with HTTPS, then use no permit all followed by permit [vlan | mgmt
| all]. For detailed instructions, refer to Permitting Access, on page 8-5 of the
ARX® CLI Network-Management Guide.
For example, the following command sequence stops and restarts the GUI,
then shows that the GUI recreated the “acopia.keystore” file:
bstnA# config
bstnA(cfg)# management access https
bstnA(cfg‐mgmt‐access[HTTPS])# no permit all
bstnA(cfg‐mgmt‐access[HTTPS])# permit all
bstnA(cfg‐mgmt‐access[HTTPS])# show configs
configs
wwmed.keystore Aug 9 11:20 1.2 kB
active.license Sep 15 15:19 3.4 kB
api‐ssl.crt Aug 9 12:49 1009 B
api‐ssl.key Aug 9 12:49 891 B
arx.dossier Sep 15 15:19 3.0 kB
boot‐config Sep 16 00:46 1.5 kB
eeprom.dat Sep 16 00:13 119 B
encoded.license Sep 15 15:19 3.5 kB
nlad_smb.conf Sep 16 00:13 44 B
nlad.conf Sep 16 00:43 24 B
oem‐menu‐log.txt Sep 16 00:07 3.0 kB
omDbVersion.info Sep 16 00:11 280 B
startup‐config Sep 16 01:31 7.3 MB
unparsed.license Sep 15 15:19 3.4 kB
bstnA(cfg‐mgmt‐access[HTTPS])# ...
CLI Maintenance Guide
12 - 5
Chapter 12
GUI Maintenance
12 - 6
13
Powering Down the ARX
• Overview
• Saving Configuration Parameters
• Checking the NVRAM Battery
• Turning Off the Power
• Limited Down Time
• Restoring Power
Overview
Overview
You can power down the ARX-500, ARX-2000, or ARX-4000 with a CLI
command. This cuts power from all systems except the Non-Volatile RAM
(NVRAM). The NVRAM contains namespace metadata information that
managed volumes are currently using. Other platforms require a manual
power-off sequence, which cuts power from all systems including the
NVRAM. Once the NVRAM loses power from an external source, it uses a
battery backup for up to 72 hours.
This chapter describes how to power down a single ARX and a redundant
pair of them. This prepares the ARX pair for a planned power outage.
For power outages of greater than 72 hours, contact F5 Support.
Note
The ARX-VE is a software-only virtual appliance, and the instructions
provided here for turning off power, turning on power, and checking the
NVRAM battery are not relevant to its operation. Instead, you should refer
to the user documentation for your third-party hardware for relevant
instructions related to power-down and power-up. However, the software
practices described here, including saving configuration parameters and
verifying services and overall system health after power has been restored,
are relevant to all versions of the ARX, including ARX-VE.
Saving Configuration Parameters
Save a copy of the ARX configuration. The configuration parameters are
divided into two classes: running-config and global-config. The
running-config has all of the chassis, network, and redundancy parameters;
all of the CLI commands for running-config are under “cfg” mode. The
global-config contains all namespaces, volumes, global servers, policy rules,
and other storage parameters. The CLI commands for global-config are
under “gbl” mode. Save a copy of both the running-config and the
global-config. An earlier chapter described all of this: recall Backing Up the
Running Configuration, on page 5-1.
Use the copy running-config and copy global-config commands to copy the
files off of the switch. For example, the following command sequence
copies the running-config and global-config off of the “bstnA” switch to a
remote FTP server:
bstnA# copy running‐config ftp://juser:jpasswd@172.16.100.183//var/a6k‐running.cfg
% INFO: The copy command completed successfully.
bstnA# copy global‐config ftp://juser:jpasswd@172.16.100.183//var/a6k‐global.cfg
% INFO: The copy command completed successfully.
bstnA# ...
If the ARX has a redundant peer, copy the running-config off of the peer,
too. You do not need to copy the global-config, which is shared between the
peers. For example,
CLI Maintenance Guide
13 - 3
Chapter 13
Powering Down the ARX
bstnB# copy running‐config ftp://juser:jpasswd@172.16.100.183//var/a6kB‐running.cfg
% INFO: The copy command completed successfully.
bstnB# ...
13 - 4
Checking the NVRAM Battery
Checking the NVRAM Battery
The Non-Volatile RAM (NVRAM) memory contains namespace metadata
information that managed volumes are currently using. If this memory is
lost, all managed volumes must re-import all of their back-end shares. To
protect against this time-consuming process, the NVRAM chip has a
separate battery backup that lasts up to 72 hours.
Before you shut down any services, use the show chassis nvr command to
verify that the battery is in good working order. The output must indicate
that the battery is in a “Good” state and that the Error-Correction Circuitry
(ECC) indicates that the NVRAM has “No Error.” Run this on both peers if
you have redundancy configured.
For example, this output indicates that the “bstnA” chassis has a battery that
is ready for power-off:
bstnA# show chassis nvr
NVR:
NVR Battery ECC State NVR Size (MB)
‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐
Good No Error 2048
bstnA#
This example shows that the redundant peer, “bstnB,” also has a
fully-charged battery:
bstnB# show chassis nvr
NVR:
NVR Battery ECC State NVR Size (MB)
‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐
Good No Error 2048
bstnB#
Important
Contact F5 Support if your output does not match the above NVR Battery
and ECC State.
CLI Maintenance Guide
13 - 5
Chapter 13
Powering Down the ARX
Turning Off the Power
By this time, all ARX clients should be aware of the impending service
outage. In a redundant pair, turn the power off at the backup switch first,
then the active switch. On an ARX-500, ARX-2000, or ARX-4000, you can
go to priv-exec mode and use the shutdown command:
shutdown
The CLI prompts for confirmation before shutting down the power; enter
yes to proceed with the shutdown.
For example, this shuts down all power on the “bstnA” switch:
bstnA# shutdown
This command turns off the chassis and powers it down.
You will need to manually restore power to return the chassis to service.
Are you sure? [yes/no] yes
...
After you turn off the power, the battery for the NVRAM lasts up to 72
hours.
Manually Turning Off the Power
If you are on site, you can shut down the ARX manually. Press the power
button or flip the power switch(es) on the chassis. These are located in
different places on each platform:
• ARX-500 - a button on the right side of the front panel (see the ARX®–
500 Hardware Installation Guide).
• ARX-1500 - a switch toward the left side of the rear panel (see the
ARX®–1500 Hardware Installation Guide).
• ARX-2000 - a button on the upper-left of the front panel (see the ARX®–
2000 Hardware Installation Guide).
• ARX-2500 - a switch toward the left side of the rear panel (see the
ARX®–2500 Hardware Installation Guide).
• ARX-4000 - a button on the upper-left of the front panel (see the ARX®–
4000 Hardware Installation Guide).
Limited Down Time
As mentioned above, the NVRAM battery drains in 72 hours. If you do not
restore power in that time, all managed volumes will re-import their
back-end shares after you power on. Depending on the size of the directory
trees in these shares, import can be a time-consuming process.
13 - 6
Restoring Power
Restoring Power
To watch the boot-up messages as the system powers up, you can connect a
serial line to the ARX’s Console port. Each Hardware Installation guide
shows the location of this port, a 9600-baud, 8-N-1 terminal.
For any chassis type, you turn the power back on with the power button or
switch(es). The boot sequence takes more than one minute to complete.
After the boot sequence finishes, the Console prompts for authentication:
...
User Access Authentication
Username: Verifying Successful Power-Up
Use the CLI to verify that all services are back online.
Showing Overall Health
The show health command should not indicate any open alarms. For
example, this system is in good overall health:
bstnA(cfg)# show health
System Health Information
Date ID Event Description
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Fri Jul 21 03:54:38 (0) ‐ No active alarms.
bstnA(cfg)# ...
Repeat this command on the redundant switch if you have one. This
example shows that the peer switch is also in good overall health:
bstnB(cfg)# show health
System Health Information
Date ID Event Description
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Fri Jul 21 03:55:08 (0) ‐ No active alarms.
bstnB(cfg)# ...
Showing Namespace Status
The show namespace status all command shows the state of all namespaces,
volumes, and shares. This is described in the ARX® CLI
Storage-Management Guide; see Monitoring the Import, on page 9-56. The
“Status” for each volume should be “Enabled.” Each share should have a
Status of “Online;” if the switch or switches were powered off for more than
72 hours, they may be “Pending” or “Importing” for some time before they
transition to an “Online” state.
CLI Maintenance Guide
13 - 7
Chapter 13
Powering Down the ARX
For example, the namespaces on “bstnA” have all volumes enabled and all
shares online:
bstnA(cfg)# show namespace status all
Namespace: medco
Description:
Share Filer Status
NFS Export
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐
Volume: /vol Enabled
corporate nas1 Online
NFS: /vol/vol1
sales nas2 Online
NFS: /vol/datavol1/direct
generic nas3 Online
NFS: /vol/vol2/direct
Namespace: wwmed
Description:
Share Filer Status
NFS Export
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐
Volume: /acct Enabled
budget das1 Online
NFS: /exports/budget
bills das8 Online
NFS: /work1/accting
bills2 das3 Online
NFS: /exports/acct2
it5 das7 Online
NFS: /lhome/it5
metadata‐share nas1 Online
NFS: /vol/vol1/meta1
Namespace: medarcv
Description:
Share Filer Status
CIFS Share
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐
Volume: /lab_equipment Enabled
equip nas10 Online
CIFS: equipment
backlots fs2 Online
CIFS: backlot_records
leased nas10 Online
CIFS: for_lease
13 - 8
Restoring Power
scanners fs5 Online
CIFS: xraysScanners
metadata‐share nas1 Online
NFS: /vol/vol1/meta6
[rs] equipSnap nas11 Online
CIFS: equipBkup
[rs] leasedSnap nas11 Online
CIFS: leasedBkup
[rs] : replica‐snap share
Volume: /rcrds Enabled
rx fs4 Online
CIFS: prescriptions
charts fs1 Online
CIFS: histories
bulk fs2 Online
CIFS: bulkstorage
metadata‐share nas1 Online
NFS: /vol/vol1/meta3
Volume: /test_results Enabled
chemistry fs1 Online
CIFS: chem_results
hematology fs3 Online
CIFS: hematology_results
2005_charts medarcv Online
Path: /rcrds
Namespace: insur
Description:
Share Filer Status
CIFS Share
NFS Export
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐
Volume: /claims Enabled
shr1‐old nas1 Online
CIFS: insurance
NFS: /vol/vol1/NTFS_QTREE/insurance
metadata‐share nas1 Online
NFS: /vol/vol1/meta2
shr1‐next nasE1 Online
CIFS: patient_records
NFS: /root_vdm_4/patient_records
bstnA(cfg)# ...
CLI Maintenance Guide
13 - 9
Chapter 13
Powering Down the ARX
Showing Front-End Service Health
Use show virtual service to verify that all NFS and/or CIFS services are
running properly. In a redundant pair, these services only run on the active
peer. All services should have a state of “Ready.” For example, this ARX
has all of its services running:
bstnA(cfg)# show virtual service
Switch: bstnA
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
Global Server Virtual IP Address Service State
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
acopiaFiler 192.168.25.12 NFS Ready
ac1.MEDARCH.ORG 192.168.25.15 NFS Ready
ac1.MEDARCH.ORG 192.168.25.15 CIFS Ready
bstnA(cfg)# ...
Showing a Healthy Redundancy Configuration
For a pair of redundant switches, check the redundancy configuration from
either peer. Use show redundancy all, and check for the status shown in the
example below (important status is highlighted in bold):
bstnA(cfg)# show redundancy all
Transitions
Node Switch/Quorum Disk Status Role Total Last (UTC)
‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐ ‐‐‐‐‐‐‐ ‐‐‐‐‐ ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
*1 bstnA Up Active Never ‐
2 bstnB Up Backup 1 07:37:08 07/21/2006
QD 192.168.25.234 Up Quorum 1 07:36:57 07/21/2006
Date/Time(UTC) Recent History
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
07‐21 07:37:13 Quorum disk is online, system is ready for failover
07‐21 07:37:08 Pair status changed from JoinWait to Formed
07‐21 07:37:08 Peer switch 'bstnB' is now online
...
13 - 10
14
ARX Disaster Recovery
• Overview
• Before You Begin
• Disaster Recovery Configuration
• Conflict Resolution For Replicated Configurations
Overview
Overview
An ARX cluster comprises two ARXes that are paired in a redundant
configuration for high-availability. The ARX supports disaster recovery for
ARX clusters that reside at geographically separate sites. Disaster recovery
works by failing over services, volumes, and shares from an active ARX
cluster that is unable to continue operating to a backup ARX cluster at a
different site that has been prepared to take over for the active ARX cluster
and waits passively until it is activated explicitly. The failover process
executes efficiently to ensure a short recovery time, enabling ARX clients to
continue accessing their volumes and shares with only a minimal
interruption of service. The feature requires that file servers or other
back-end storage arrays provide the replication of user data from the active
site to the backup site.
All ARXes used in a disaster recovery configuration must be the same
model and must be running the same revision of the ARX software.
ARX disaster recovery consists of the following high level steps:
1. Ensure that both the active and the backup ARX clusters are
configured for networking (via the running-config), and that the
active ARX cluster is configured with your current storage
configuration (via the global-config).
2. Define a name for both the active and backup ARX clusters; this is
simply a name given to the ARX HA pair at the corresponding site.
3. Set site-specific parameters in the active ARX cluster’s
global-config. The active ARX cluster’s global-config will contain
many common configuration elements, but it contains also a small
number of cluster-specific configuration elements that
accommodate site-specific variations, such as differences in the IP
addresses at the two sites. This global-config that has been set with
both active and backup site parameters is a “shared” global-config.
4. Set up a configuration replication task for replicating the active
ARX cluster’s global-config to the ARX cluster at the backup site.
The configuration replication occurs according to a user-configured
schedule. This ensures that a recent copy of the shared global-config
resides on the backup ARX cluster.
5. Execute the procedure for performing a failover from the active
cluster to the backup cluster. Failover from the active cluster to the
backup cluster occurs when you initiate the failover process
explicitly, and load and activate the shared global-config on the
backup cluster. These steps must be coordinated with other data
center failover steps, such as failing over between file servers in the
active and backup data centers.
This chapter describes the process of configuring two ARX clusters for
disaster recovery. The examples provided throughout this chapter describe
the configuration of an active cluster named “Providence”, comprising the
CLI Maintenance Guide
14 - 3
Chapter 14
ARX Disaster Recovery
ARXes “provA” and “provB”, and a backup cluster named “Newport”,
comprising the ARXes “nwptA” and “nwptB”. The global configuration
defines two managed volumes, /mds and /rns, which are exported from the
filers “prov” and “pr-1” at the Providence site and from the filers “nwpt”
and “npt-2” at the Newport site.
The first figure below illustrates the disaster recovery configuration, with
the Providence cluster active and the Newport cluster configured as its
backup. Note the replication of client data from the file servers at the active
site to those at the backup site, and also the replication of the ARX shared
global-config.
The second figure illustrates an actual disaster recovery situation, in which
the Providence cluster is unable to continue operating, and the ARX
administrator has executed the failover process for both the filer servers and
14 - 4
Overview
the ARX clusters. The shared global-config has been loaded and activated
on the Newport cluster, and the Newport ARXes now provide access to the
client data.
Throughout the examples in this chapter, substitute host names and IP
addresses as appropriate to mimic the example configuration in your own
network.
Note
This chapter uses the terms “active” and “backup” to indicate which
cluster or site is being described, and uses the term “current” when
referring to the cluster or site for which you are executing actions to carry
out a given instruction. However, be aware that the ARX product interface
may refer to a cluster or site as being “local” (the active cluster or site, for
which you execute most actions) or “remote” (the backup cluster or site,
which waits ready to take over for the active cluster or site).
CLI Maintenance Guide
14 - 5
Chapter 14
ARX Disaster Recovery
Before You Begin
This section describes several preliminary tasks that must be completed to
prepare ARX clusters for disaster recovery.
Preparing Back-End Filers
Begin by using filer-replication applications (such as NetApp’s SnapMirror,
EMC’s SRDF, or RoboCopy) to duplicate the storage from an active site to
a backup site. Continuously replicate all of the back-end shares behind the
ARX. Also create back-end shares for managed-volume metadata at the
backup site, but do not replicate the source site’s metadata. The ARX
software at the backup site will recreate the metadata there.
Verifying That Master Keys Are Identical
Ensure that all of the ARXes at both sites use the same master key. The
ARXs’ master keys must be identical in order for the ARXes to share a
global-config. The best practice is to synchronize the master keys at
installation time, as described in the ARX Hardware Installation guides.
Execute the show master-key command on each ARX to display an
encrypted version of its master key. If the backup switches have the wrong
master key, reset them to their factory default configurations and change the
master keys to the appropriate values.
An example of the output from the show master-key command follows;
note that you must type the system password and the wrapping password for
the chassis when prompted to do so:
provA(cfg)# show master‐key
System Password: %uper$ecretpw
Wrapping Password: an0ther$ecretpw
Validate Wrapping Password: an0ther$ecretpw
Encrypted master key:
2oftVCwAAAAgAAAApwazSRFd2ww/H1pi7R7JMDZ9SoIg4WGA/XsZP+HcXjsIAAAADDRbM
CxE/bc=
provA(cfg)#
For detailed information about using this command, refer to the show
master-key description in the ARX CLI Reference.
You must clear your entire configuration to reset your master key.
Follow these steps to reset an ARX back to its factory defaults and reset its
master key:
1. Use the copy running-config command to copy the entire running
configuration (network-level parameters, not storage parameters)
into a file on the chassis.
2. The ARX should not be running any storage services if it is
designated as a backup; a backup is designed to take over services
from the active switch or cluster after a failover. Use the remove
14 - 6
Before You Begin
service command to clear each service that is running currently, if
any. This cleanly de-couples the ARX software from all back-end
filers.
3. Connect a serial cable to the Console port. Only the Console port is
available after you execute the next step.
4. Use the delete startup-config and delete configs boot-config
commands to delete the entire configuration, and then execute the
reload command. This resets the ARX to its factory defaults,
disables all management IP interfaces, and reruns the initial-boot
script at the Console port.
5. Use the initial-boot script to reset the master key. For detailed
instructions on the initial-boot process, refer to the hardware
installation guide for your chassis.
6. Invoke the run command on the running-config file that you saved
onto the chassis earlier. This re-establishes all of your network
parameters.
Removing Existing Global Configuration From the Backup ARXes
At the beginning of the disaster recovery configuration process, the ARXes
at the backup site should have only their master keys and their network
parameters configured (i.e., the running-config); no global-config should be
present. This is not typically an issue when configuring brand new ARXes
for the first time, but may be a necessary consideration if you are using
ARXes that have been deployed and configured previously.
The privileged-exec mode CLI command clear global-config removes the
global-config.
For example, the following command deletes the global-config for the
current ARX cluster:
provA# clear global‐config
Configuring a RON Mesh
All ARXes in both clusters must be configured with RON tunnels to all of
the other ARXes, creating a full mesh. Use the ron tunnel CLI command to
connect both ARXes at the active site to both ARXes at the backup site.
For example, the following series of commands creates a RON tunnel
named “toNewport” from the ARX named ProvA to the ARX with an IP
address of 192.168.8.106 at the Newport site.
provA# config
provA(cfg)# interface vlan 103
provA(cfg‐if‐vlan[103])# ron tunnel toNewport
provA(cfg‐if‐vlan‐ron‐tnl[103~toNewport])# peer address 192.168.8.106
provA(cfg‐if‐vlan‐ron‐tnl[103~toNewport])# no shutdown
CLI Maintenance Guide
14 - 7
Chapter 14
ARX Disaster Recovery
provA(cfg‐if‐vlan‐ron‐tnl[103~toNewport])# exit
provA(cfg‐if‐vlan[103])# Repeat this command sequence for the other side of the tunnel, from the
Newport ARXes to the Providence ARXes.
14 - 8
Disaster Recovery Configuration
Disaster Recovery Configuration
This section describes the tasks you need to perform to configure the ARXes
for disaster recovery.
Disaster Recovery Configuration Summary
Configuring ARX clusters and preparing for disaster recovery comprises the
following tasks, each of which is described in its own section:
• Defining Cluster Names
• Adding the Backup Cluster’s Filers to the Active Cluster’s Configuration
• Assigning SAM-Reference Filers
• Assigning Metadata Shares
• Assigning Volume Shares
• Assigning VIPs For Each Cluster
• Adding the Backup Cluster’s Filers to the CIFS Service’s Delegate-To
List
• Replicating the Global Config to the Backup Cluster
• Manual Failover Tasks
• Loading a Configuration on the Backup Cluster
• Activating a Configuration on the Backup Cluster
Defining Cluster Names
Use the cluster-name CLI command to specify a name for each cluster and
the ARXes that belong to it. Each cluster must be named uniquely.
The command syntax is:
[no] cluster-name name {member switch‐name member switch‐name}
Where name is the cluster you are defining, and switch-name is the name of
an individual ARX that will belong to the cluster.
For example, the following command creates an ARX cluster named
“providence” that comprises the ARXes “provA” and “provB”:
provA(gbl)# cluster‐name providence member provA member provB
The configuration supports the use of two clusters at a time.
Changing a Cluster Name
To change an existing cluster name, you must remove the cluster name from
the global configuration first. Use the remove cluster-config command in
privileged exec mode to do this.
The command syntax is:
CLI Maintenance Guide
14 - 9
Chapter 14
ARX Disaster Recovery
remove cluster‐config clustername
where clustername is the name of the cluster for which you want to remove
the name from the global configuration. If you specify “localcluster” as the
cluster name, the name of the current cluster is removed from the global
configuration.
For a remote cluster, this removes the following objects from the system:
• any filer
• any metadata share
• any virtual server that resides in the cluster
For the local cluster, this removes only the cluster name from the objects
listed above. They remain in the configuration, but without the cluster name
as part of their definitions.
The CLI prompts for confirmation before removing or changing any
configuration objects; type “yes” to proceed.
After the cluster name has been cleared, you can define a new cluster name
as described in the previous section.
Adding the Backup Cluster’s Filers to the Active Cluster’s
Configuration
In order for all client data to be accessed reliably and transparently by the
ARXes at both sites, the filers at the backup cluster’s site must be included
in the active cluster’s configuration. (This is part of the global configuration
that is in turn replicated from the active site to the backup site.) For
complete instructions for doing this, refer to the ARX® CLI
Storage-Management Guide, Appendix 6, Adding an External Filer.
For example, the following commands show the addition to the Providence
configuration of two filers at the Newport site, named “nwpt” and “npt2”.
The name and IP address of each is specified, along with a brief description,
the management protocol to be used, and the proxy user ID for each. In
addition, snapshot support is configured for each. The exit command at the
end of each command sequence quits gbl-filer mode.
For example, the following commands configure the addition of the filer
“nwpt”:
provA(gbl)# external‐filer nwpt
provA(gbl‐filer[nwpt])# ip address 172.16.200.1
provA(gbl‐filer[nwpt])# description "big filer in Newport's front lab"
provA(gbl‐filer[nwpt])# filer‐type network‐appliance management‐protocol rsh
provA(gbl‐filer[nwpt])# proxy‐user unxAdmin
manage snapshots
provA(gbl‐filer[nwpt])# exit
The following commands configure the addition of the filer “npt2”:
14 - 10
Disaster Recovery Configuration
provA(gbl)# external‐filer npt2
provA(gbl‐filer[npt2])# ip address 172.16.200.2
provA(gbl‐filer[npt2])# description "New filer, rack 4 (Newport)"
provA(gbl‐filer[npt2])# filer‐type network‐appliance management‐protocol rsh
provA(gbl‐filer[npt2])# proxy‐user unxAdmin
provA(gbl‐filer[npt2])# manage snapshots
provA(gbl‐filer[npt2])# exit
Assigning SAM-Reference Filers
If you are using CIFS local groups, you may want to assign a security
account management (SAM) reference filer per site. Use the
sam-reference command with its cluster argument to specify the cluster
with which the external filer is associated. The command syntax is:
sam‐reference filer cluster clustername
where clustername specifies the cluster with which filer is associated.
Note
Execute the sam reference command twice when configuring for disaster
recovery: once to specify the SAM reference filer at the active cluster, and
again to specify it at the backup cluster.
Refer to Selecting a SAM-Reference Filer in the ARX® CLI
Storage-Management Guide for complete information about SAM-reference
filers and the use of this command.
For example, the following commands specify pr-1 as the SAM-reference
filer for the Providence cluster, and npt2 as the SAM-reference filer for the
Newport cluster:
provA(gbl‐ns[provMed])# sam‐reference pr‐1 cluster providence
provA(gbl‐ns[provMed])# sam‐reference npt2 cluster newport
Assigning Metadata Shares
For each managed volume in the configuration, you need to define metadata
shares for each site. Use the metadata share command to specify a
metadata share for use with a particular cluster. The command syntax is:
metadata share filer {nfs3 | nfs3tcp | cifs} path [cluster cl‐name]
CLI Maintenance Guide
14 - 11
Chapter 14
ARX Disaster Recovery
where filer is the name of the external filer, path is the share path on the
filer, and cl-name is cluster that will use filer.
Note
Execute the metadata share command twice per volume when configuring
for disaster recovery: once to specify the metadata share’s host at the active
cluster, and again to specify the metadata host at the backup cluster. The
two metadata shares need to use the same protocol.
Refer to Storing Volume Metadata on a Dedicated Share in the ARX® CLI
Storage-Management Guide for complete information about metadata
shares.
For example, the following commands specify the path to the metadata
share on filer pr-1 for the Providence cluster, and the path to the metadata
share on filer npt2 for the Newport cluster.
provA(gbl‐ns[provMed])#volume /mds
provA(gbl‐ns‐vol[provMed~mds])# metadata share pr‐1 nfs3 /vol/vol3/arx_meta cluster providence
provA(gbl‐ns‐vol[provMed~mds])# metadata share npt2 nfs3 /vol/vol3/arxMeta cluster newport
Assigning Volume Shares
For each managed volume share configuration, you need to define per site
configuration. For each ARX share, a filer and share can be configured per
cluster. Assign the shares to a filer and cluster using the filer command. The
command syntax is:
filer filer {nfs sharename | cifs sharename} [access‐list listname] [cluster clustername]
where filer is the name of the filer that hosts the share in question, nfs
sharename or cifs sharename is the share to be associated with the cluster,
listname is the ACL associated with the share, and clustername is the cluster
to which this configuration is relevant.
Note
Execute the filer command twice per share when configuring for disaster
recovery: once to specify the share’s filer at the active cluster, and again to
specify the share’s filer at the backup cluster.
For example:
provA(gbl‐ns‐vol[provMed~mds])# share mds
provA(gbl‐ns‐vol‐shr[provMed~mds~mds])# filer pr‐1 cifs ${TEST_UNAME}MDS cluster providence
provA(gbl‐ns‐vol‐shr[provMed~mds~mds])# filer npt2 cifs ${TEST_UNAME}MDS cluster newport
provA(gbl‐ns‐vol‐shr[provMed~mds~mds])# exit
14 - 12
Disaster Recovery Configuration
provA(gbl‐ns‐vol[provMed~mds])# share rns
provA(gbl‐ns‐vol‐shr[provMed~mds~rns])# filer prov cifs ${TEST_UNAME}RNS cluster providence
provA(gbl‐ns‐vol‐shr[provMed~mds~rns])# filer nwpt cifs ${TEST_UNAME}RNS cluster newport
provA(gbl‐ns‐vol‐shr[provMed~mds~rns])# exit
Assigning VIPs For Each Cluster
Each ARX cluster may have a unique virtual IP address (VIP) assigned to it
to be accessed by ARX clients. In some disaster recovery configurations, a
per site VIP may be required. The command syntax is:
virtual server switchname vip mask [vlan vlan‐id] [cluster clustername]
Where switchname is the name of the network switch, vip is the IP address
assigned to the virtual server, mask is the network subnet mask associated
with that IP address, vlan-id is the VLAN on which virtual server is a node,
and clustername is the cluster to which this configuration is relevant.
For example, the following command specifies the cluster name
“providence” for the virtual server 192.168.103.55, with VLAN 103, on the
ARX named “provA”:
provA(gbl‐gs[provmed.MEDARCH.ORG])# virtual server provA 192.168.103.55 255.255.255.0 vlan 103 cluster providence
Note
All configuration in global server mode is shared between virtual servers.
Adding the Backup Cluster’s Filers to the CIFS Service’s
Delegate-To List
If you are running CIFS services with constrained delegation, some
additional configuration of the domain controller will be necessary to
support your CIFS clients. The back-end CIFS servers at the backup cluster
must be on the “delegate-to” list for each front-end CIFS service. For each
CIFS service, execute the probe delegate-to command to find any
back-end servers that need to be added to the list, and add them at the
domain controller. When complete, the CIFS service’s “delegate-to” list
includes the back-end servers behind both clusters. This configuration is
performed at the DC, and persists after the “load-configs” test.
Replicating the Global Config to the Backup Cluster
Replication of the global configuration from the active cluster to a backup
cluster is controlled by a user-configured replication task. Define the
replication task using the global-config mode CLI command
CLI Maintenance Guide
14 - 13
Chapter 14
ARX Disaster Recovery
config-replication. This command creates a task that replicates the active
ARX’s global-config by a user-defined schedule to the target ARX cluster.
The source ARX will use the cluster name to resolve the target ARXes from
the configured target cluster. The best RON route will be used for reaching
the switches in the target cluster.
Replication begins when it is enabled, and occurs according to the frequency
and times defined in the associated schedule. During the process, a copy of
the global configuration is replicated to both members of the target cluster,
into the configs directory on the system disks of the target switches. The
filename of the global configuration on the target switch will be whatever
the user specified in the replication task configuration. If the target filename
exists already on the target switch, the replication will ensure transactionally
that it is not overwritten until the latest configuration replication is
complete.
Executing the config-replication command creates the config-replication
object and enters gbl-cfg-repl mode. The command syntax is:
config‐replication name cluster clustername
Where name is the replication task you are creating and clustername is the
ARX cluster from which the global-config originates.
For example, the following command defines a replication task named
“prov2newport” which replicates the global configuration from the source
cluster Providence to the target cluster Newport:
provA(gbl)# config‐replication prov2newport cluster providence
Subsequently, the CLI is in gbl-cfg-repl mode, enabling you to specify the
details of the configuration replication task, such as the target cluster, the
target filename, the schedule used to control the frequency at which the
replication task runs, and the administrative user account and password used
to authenticate to the target cluster.
For example, the following command sequence specifies an ARX
administrative user named “admin” with a password of “acopia”; the target
filename is “provSvcs.rcfg”, and it is replicated according to the schedule
named “oncePerDay” to the target cluster “newport”. Additional commands
name the prefix of the replication report and define a textual description of
the replication object. The enable command puts the replication task into
effect.
provA(gbl‐cfg‐repl[prov2newport])# target‐cluster newport
provA(gbl‐cfg‐repl[prov2newport])# user admin
Password: ******
Validate password: ******
provA(gbl‐cfg‐repl[prov2newport])# target‐file provSvcs.rcfg
provA(gbl‐cfg‐repl[prov2newport])# schedule oncePerDay
provA(gbl‐cfg‐repl[prov2newport])# report gblRepl2newport
provA(gbl‐cfg‐repl[prov2newport])# description "send service config to Newport site"
provA(gbl‐cfg‐repl[prov2newport])# enable
provA(gbl‐cfg‐repl[prov2newport])# exit
14 - 14
Disaster Recovery Configuration
provA(gbl)#
Use the show config-replication command to see the current status of one
or more config-replication rules.
Use the show replicated-configs command to list the global configurations
that have been replicated to the current ARX.
Refer to Appendix 12, Creating a Policy Schedule in the ARX® CLI
Storage-Management Guide for complete information about defining and
using schedules.
Manual Failover Tasks
You must execute the following tasks manually when failing over from the
previously active cluster to the backup cluster:
1. Disable the replication of the ARX global configuration by
executing the no enable command in gbl-cfg-repl mode.
2. Halt the active ARX cluster’s front-end services if the active cluster
is still viable. Do this by executing no enable for each CIFS/NFS
service and for the global server.
3. Halt file server replication.
4. Fail over the file server infrastructure from the active cluster to the
backup cluster. The backup site file server volumes/file systems
now are read-write and available.
5. Load the latest replicated global-config from the previously active
cluster onto the backup ARX cluster. Refer to Loading a
Configuration on the Backup Cluster for details.
6. Optionally, perform an Active Directory forest re-discovery to
facilitate discovery of the backup cluster’s local domain controllers.
7. Activate the configuration that you have just loaded on the backup
ARX cluster. Refer to Activating a Configuration on the Backup
Cluster for details.
8. Your data now will be imported to the backup cluster using
seamless import.
Loading a Configuration on the Backup Cluster
The privileged-exec mode CLI command load replicated-configs enables
you to load all or part of a replicated global configuration. All objects are
loaded in a non-enabled state, regardless of whether they were enabled in
the source.
If there are conflicting objects in the global configuration, the objects that
exist already in the switch will take precedence. Conflict resolution is
described in detail in Conflict Resolution For Replicated Configurations, on
page 14-18.
CLI Maintenance Guide
14 - 15
Chapter 14
ARX Disaster Recovery
The load replicated-configs command always generates a report with all
CLI output. The report name is generated automatically and includes a
timestamp and the name of the replicated-config filename. The report type
name is “Load”.
The command syntax is:
load replicated‐configs filename [global‐server gsname] [tentative]
Where filename is the name of the replicated configuration file and gsname
is the name of the global server on which the replicated configuration will
be loaded.
For example,
provA# load replicated‐configs provSvcs.rcfg global‐server ac1.medarch.org
This command loads the global configuration named “provSvcs.rcfg” on the
global server named “ac1.medarch.org”.
Note
The load command may be used to load a subset of a replicated
configuration based on global-server. This is an advanced option; consult
F5 technical support before attempting to use it.
Testing the Load Configs Operation
After the global-config has been copied successfully to the backup cluster,
you should test the use of the load configs tentative CLI command at that
cluster from time to time. This performs a test load of the active cluster’s
storage services onto the backup cluster.
Activating a Configuration on the Backup Cluster
The privileged-exec mode CLI command activate enables you to activate
all or part of a loaded replicated global configuration. By default, the
activation process enables all global servers, all of their associated CIFS and
NFS services, all of their referenced volumes, and all of their referenced
volume shares. By default, it does not enable volume policies; they must be
enabled explicitly. The activation process activates the loaded configuration
to maintain the original enable state of the loaded replicated global
configuration.
The activate command provides options for enabling different portions of
the loaded configuration. This enables administrators to test each portion of
a loaded replicated configuration separately. In addition, the take
ownership argument must be appended to the command in order to take
ownership of volumes that are marked as being used by other ARXes.
The activate command always creates a report. The report includes output
similar to that for the run script command. The report type name is “Act”.
The command will prompt for verification, asking the user to confirm that
the configuration should be activated.
14 - 16
Disaster Recovery Configuration
The command syntax is:
activate replicated‐configs filename [global‐server gsname] [shares] [volumes] [global‐servers] [take ownership] [policies] [tentative]
Where filename is the name of the replicated configuration file and gsname
is the name of the global server on which the replicated configuration will
be activated.
For example,
provA# activate replicated‐configs provSvcs.rcfg global‐server ac1.medarch.org
This command activates the replicated configuration named “provSvcs.rcfg”
on the global server named “ac1.medarch.org”.
Note
Executing this command by specifying a filename without any additional
arguments will enable all shares, volumes, and global-servers by default. In
order to activate policies, the policies option must be specified explicitly.
The best practice is to activate the configuration in stages:
1. Activate shares only, with take ownership.
2. Activate volumes only. This will begin the online import process.
3. Test connectivity to ARX exports and volumes.
4. Activate policies.
Executing ARX Cluster Failback
When failover takes place, the backup ARX cluster becomes the active
ARX cluster. The newly active cluster can run for an indefinite period of
time, and can have configuration changes made to it. When you want to
initiate a failback to the previously active cluster, execute the same actions
described in these earlier sections:
• Manual Failover Tasks, on page 14-15
• Loading a Configuration on the Backup Cluster, on page 14-15
• Activating a Configuration on the Backup Cluster, on page 14-16
Note
The configuration of the target switch must be updated to accommodate any
global-level configuration changes that were made after the initial failover.
CLI Maintenance Guide
14 - 17
Chapter 14
ARX Disaster Recovery
Conflict Resolution For Replicated Configurations
When loading a configuration, a conflict may occur with the existing
configuration on the current ARX. If you have followed the instructions
provided in this chapter, you should not encounter any configuration
conflicts. However, if you have worked with F5 customer support to define
an alternative configuration that is not covered by the preceding
instructions, and you’ve encountered configuration conflicts subsequently,
this section will assist you in addressing those conflicts.
The general principles of conflict resolution for replicated global configs
follow:
• Conflicts are detected based on the name of the object or the name of the
command.
• For most conflicts, the object or command that exists on the current
switch already takes precedence over the one in the replicated
configuration. The exception to this is in the handling of namespaces;
this is described in detail in Resolving Conflicts in Namespaces, on page
14-19.
• If there is a conflict, the existing object or command on the switch will
not be altered in any way.
In general, most potential conflicts occur with objects at the top level of the
global configuration (schedules, filesets, etc.).
Resolving Top-Level Conflicts
These conflict resolution principles enable administrators to have preset
cluster-specific top-level configuration objects. Cluster-specific top-level
objects are pre-configured (e.g., NTLM authentication servers and Active
Directory forests). When the configuration is loaded, the conflict resolution
allows the local predefined objects to remain.
The top-level objects for which conflicts could occur are:
• active-directory
• active-directory-forest
• external-filer
• file-history
• group
• kerberos
• namespace
• nfs-access-list
• nis
• ntlm-auth-db
• ntlm-auth-server
• policy-age-fileset
14 - 18
Conflict Resolution For Replicated Configurations
• policy-filename-fileset
• policy-filesize-fileset
• policy-intersection-fileset
• policy-union-fileset
• proxy-user
• radius-server
• schedule
• user
• volume group
• windows-mgmt-auth
Resolving Conflicts in Namespaces
The exception in which global configuration replication conflicts are
handled differently is that of namespaces. This is because a failover may
involve a set of volumes inside a namespace.
Namespaces are handled as follows:
• Conflicting namespace names are allowed.
• If there is a conflict in the namespace name, no namespace-specific
parameters in the active configuration will be altered (such as the
protocol).
• Conflicts involving volumes are handled as described in the previous
section.
• An NFS presentation volume can be configured to attach to a managed
volume in another namespace. This case is not addressed in the loading
of the configuration.
CLI Maintenance Guide
14 - 19
Chapter 14
ARX Disaster Recovery
14 - 20
Index
Index
'8.3' names in a CIFS volume 10-55
A
ACLs
support for CIFS share-level ACLs 7-30
activate replicated-configs 14-16
Adaptive Resource Switch (ARX) 1-3
additional-command 8-38
AGN 10-68
Alarms
showing active alarms 8-4
archive 3-12
ARX 1-3
ARX-generated names (AGNs) 10-68
auto-diagnostics 8-37
B
Backups
for running-config 5-1
for volume 4-1
restoring 4-7
restoring configuration 5-21
volume snapshots 2-1, 3-1
boot system 6-13
C
cancel migrate-metadata 7-41
cancel migration 10-78
cancel nsck report 7-11, 7-21
cancel remove 10-25
cancel restore data 4-14
cancel snapshot archive 3-16
cancel sync files 7-29
Capture
saving IP traffic into a file 9-16
capture merge 9-23
capture session 9-16
Case-blind collisions 10-67
cfg mode 1-7
Checkpoints. See Snapshots.
CIFS
'8.3' naming collisions 10-55
closing an open file 11-18
dropping a client session 11-14
dropping all connections to a filer 9-29, 9-30
illegal characters in CIFS-entry names
NFS characters 10-67
trailing characters 10-59
leaving and rejoining an AD domain 11-22
showing filer-connection statistics 9-28
showing front-end CIFS services
listing client sessions 11-10
listing open files 11-15
CLI Maintenance Guide
showing client-activity 11-14
showing client-connection stats 11-3
showing Kerberos tickets 11-20
troubleshooting 11-1
cifs rekey
recovery if the rekey is too late 11-22
clear file-history archive 3-39
clear nsck 7-39
clear restore data 4-13
clear sync files 7-28
CLI conventions
no 1-8
close cifs file 11-18
Cluster
name
defining 14-9
renaming 14-9
Cluster configuration
cluster-specific elements, removing 14-7
conflict resolution 14-18
filer share 14-12
global configuration replication task 14-13
virtual server 14-13
Cluster failover 14-3
failback 14-17
collect capture 9-24
collect diag-info 8-30
collect logs 8-35
config-replication 14-14
contents 3-13
copy {nfs|cifs} 5-19, 8-23
copy ftp 5-21, 6-9
setting a default-FTP username/password 5-3
copy global-config 5-9
copy running-config 5-5
copy scp 6-12
copy smtp 5-7, 5-11
copy startup-config 5-18
Ctrl-z to exit a mode 1-8
D
delete releases 6-8
Disaster recovery 14-3
restoring the switch configuration 5-21
volume snapshots 2-1, 3-1
Downgrading ARX software
for redundant pair 6-27
drop cifs-service user-session 11-14
drop filer-connections 9-29, 9-30
E
enable (gbl-ns-vol-plc) 10-15
enable (gbl-ns-vol-snap) 2-14
enable, use no enable to go from priv-exec mode back
to exec mode 1-8
Index - 3
Index
enable/no enable CLI convention 1-8
end 1-8
Ethereal
packet-capture utility on the switch 9-16
exclude 2-8
Exec mode 1-7
exit 1-8
expect traceroute 9-6
expect ttcp 9-7
F
Failover, cluster 14-3
FGNs (filer-generated names) 10-52
'8.3' names in a CIFS volume 10-55
finding NFS-only files and directories 10-64
fixing NFS-only names 10-70
generating a report of NFS/CIFS naming
inconsistencies 7-18
File tracking
canceling an archive operation 3-16
clearing out a file-history archive 3-39
creating a file-history archive 3-6
querying file locations 3-25
storing file history in an archive 3-12
file-history archive 3-6
Files
finding 3-32, 10-76
finding NFS-only names in a multi-protocol volume
10-64
showing files pending migration 10-77
synchronizing with managed-volume metadata 7-22
Files, for switch maintenance
copy global-config 5-9
copy running-config 5-5
copy startup-config 5-18
show global-config 5-12
show running-config 5-8
Fileset placement
choosing the target storage 10-13
disabling 2-14, 10-16
enabling 10-15
making the rule 'tentative' 10-15
find 3-32, 10-76
firmware upgrade 6-17
Front-end services 1-4
troubleshooting CIFS 11-1
FTP
copying a software release from an FTP server 6-9
restoring running-config from an FTP server 5-21
saving a syslog file to an FTP server 8-22
saving startup (running + global) config to an FTP
server 5-18
saving the global-config to an FTP server 5-9
saving the running-config to an FTP server 5-5
setting a default username/password 5-3
Index - 4
G
gbl mode 1-7
Global commands, accessible from any mode 1-7
GUI
yearly SSL-key maintenance 12-1
I
Import
finding file-name collisions 3-32, 10-76
report 10-52
ip ftp-user 5-3
L
Latency
showing for namespace shares 10-4
load replicated-config 14-16
location 3-6
Logging
fastpath (NSM) log 9-9
logging destination 8-27
logging fastpath component 9-11
logging fastpath processor 9-9
logging level 8-24
M
mail-to (gbl-auto-diag) 8-39
Managed volume
migrating metadata 7-40
troubleshooting 10-1
Metadata
finding inconsistent metadata 7-16
migrating to a new back-end share 7-40
re-synchronizing against filers 7-22
migrate retain-files 10-14
Modes
config 1-7
exec 1-7
exiting 1-8
global commands 1-7
priv-exec 1-7
prompts 1-8
monitor module 9-25
monitor system 9-25
Multi-protocol namespace
allowing CIFS-attribute inconsistencies for NFS-only
directories 10-19
ARX-generated names (AGNs) 10-68
N
Namespace 1-3
backing up and restoring a volume 4-1
import collisions 10-45
managed-volume snapshots 2-1, 3-1
Index
nsck utility 7-1
removing an imported share 10-18
sync utility 7-22
Nested shares in a CIFS volume
adding after import 7-30
NetApp
preparing for snapshot management 2-4, 3-3
Network
ARX’s place in 1-11
troubleshooting tools 9-1
NFS
showing filer-connection statistics 9-28
NFS-only names 10-64
No Convention, to undo a CLI command 1-8
no-trail-period, marker for shares 10-61
nsck 7-1
listing reports 7-6
making a metadata-inconsistencies report 7-16
metadata-only report 7-8
nsck ... report metadata-only 7-8
nsck migrate-metadata 7-40
nsck rebuild 7-32
NSM
fastpath log 9-9
P
Packet sniffer
using internal capture utility instead 9-16
using with port mirroring 9-25
Ping
from a particular processor 9-4
with an alternative source IP 9-4
ping 9-3
Policy
showing a history of policy transactions 10-76
showing any files pending migration 10-77
Port mirroring 9-25
showing active sessions 9-26
shutting down 9-26
Powering down the switch 13-1, 14-1
Priv-exec mode 1-7
Prompts, show position in mode hierarchy 1-8
R
Reboot 6-14
Release files
upgrading 6-1
reload 6-14
remove namespace ... policy-only 10-50
Replica snapshot mode 2-46
Replica snapshot share 2-45
replica-snap 2-45
report (gbl-ns-vol-snap) 2-11, 3-15
Reports
drain-share-rule 10-21
CLI Maintenance Guide
import 10-52
listing all nsck and sync reports 7-6
metadata inconsistencies 7-16
metadata migration 7-40
metadata-only 7-8, 10-16
showing status 7-7
sync-files 7-22
Resource proxy 1-3
restore data 4-7
retain 2-8
Running-config
all scopes
saving to an FTP server 5-18
saving to an SCP server 5-19
sending to an ARX volume 5-19
global scope
saving 5-9
saving to an FTP server 5-9
saving to an SCP server 5-10
sending through E-mail 5-11
showing 5-12
local scope
saving 5-5
saving to an FTP server 5-5
saving to an SCP server 5-6
sending through E-mail 5-7
showing 5-8
S
Sample network 1-11
schedule (gbl-auto-diag) 8-37
schedule (gbl-ns-vol-snap) 2-9
SCP
copying a software release from an SCP server 6-12
saving a syslog file to an SCP server 8-22
saving startup (local + global) config to an SCP server
5-19
saving the global-config to an SCP server 5-10
saving the running-config to an SCP server 5-6
Share import error conditions 10-27
Shares
adding CIFS subshares after import 7-30
import report 10-52
showing read/write stats 10-4
show capture 9-19
show capture sessions 9-22
show cifs-service client-activity 11-14
show cifs-service exports 11-3
show cifs-service kerberos-tickets 11-20
show cifs-service open-files 11-15
show cifs-service user-sessions 11-10
show file-history virtual-service 3-25
show firmware upgrade 6-17
show global-config 5-12
show health 8-4
Index - 5
Index
show id-mappings 8-17
show logging destination 8-28
show monitor 9-26
show nsck 7-4
show policy history 10-76
show policy queue 10-77
show releases 6-7, 6-12
show reports 7-6
show reports status 7-7
show restore data 4-12
show running-config 5-8
show snapshots 2-37
show statistics filer connections 9-28
show statistics namespace 10-4
show sync files 7-27
show system tasks 8-29
show version 6-7
show virtual path-history 3-19
shutdown 13-6
SMTP
send a diagnostics file through E-mail 5-7, 5-11,
5-19, 8-32
send a global-config file through E-mail 5-11
send a running-config file through E-mail 5-7
snapshot consistency 2-29
snapshot create 2-31
snapshot directory display 2-25
snapshot directory display ... hidden 2-27
snapshot directory name 2-28
snapshot manage 2-18
snapshot privileged-access 2-24
snapshot remove 2-14
snapshot replica-snap rule 2-45
snapshot rule 2-6
snapshot verify 2-32
snapshot vss-mode 2-22, 2-25
Snapshots
applying a schedule 2-9
creating a snapshot rule 2-6
enabling a snapshot rule 2-14
enabling consistency 2-29
excluding a share 2-8
manually invoking a snapshot rule 2-31
removing from filers 2-14
replica share 2-45
restricting users of 2-23
stopping VSS support 2-25
supporting VSS for Windows2000 clients 2-22
verifying integrity 2-32
Software
arming the switch with a new release 6-13
downloading a release file 6-9
rebooting to run a new release 6-14
showing current version 6-7
showing the version of one release 6-12
upgrade procedure 6-1
Index - 6
source share 10-12
source share-farm 10-12
Split directories 10-69
SSH
running CLI commands on a remote ARX 8-42
using to run a restore data from a remote host
4-10
using to run a snapshot command from a remote
host 2-34
strict-attribute-consistency 10-19
Subshares
adding after volume import 7-30
sync directories 7-24
sync files 7-22
listing all reports 7-6
sync subshares 7-30
Syslog
copying the syslog into an ARX volume 8-23
grep 8-19
logging destination 8-27
saving log file to an FTP server 8-22
saving log file to an SCP server 8-22
showing a map of namespace, volume, and share IDs
to actual names 8-17
showing all 8-7
tailing 8-8
T
target (gbl-ns-vol-plc) 10-13
TCP
dropping all CIFS connections to a filer 9-29, 9-30
showing filer-connection statistics 9-28
tentative 10-15
Traceroute 9-6
Troubleshooting
basic tools 8-1
network-troubleshooting tools 9-1
tools for CIFS front-end services 11-1
tools for managed volumes 10-1
TTCP 9-7
U
UDP
showing filer-connection statistics 9-28
Upgrading software 6-1
V
VIP
fence for snapshots 2-29
Volume
backing up and restoring 4-1
configuring snapshots 2-1, 3-1
troubleshooting managed volumes 10-1
Index
W
Wireshark
packet-capture utility on the switch 9-16
CLI Maintenance Guide
Index - 7
Index
Index - 8
Was this manual useful for you? yes no