6 12 - D i g i t P r e c i s i o n M u l t i m e t e r HM8112-3 61⁄2 -digit display (1,200,000 counts) HO112 Scanner Card Resolution 100 nV, 100 pA, 100 μΩ, 0.01 °C/F DC basic accuracy 0.003 % 2-wire/4-wire measurements Measurement intervals adjustable from 0.1 to 60 sec. HZ42 19“ Rackmount kit 2RU Up to 100 measurements transmitted to PC per second True RMS measurement, AC+DC and AC Offset correction Precise temperature measurement with sensor RS-232 Interface, optional: USB, IEEE-488 Optional: Scanner Card (8 Channels) 61⁄2-Digit Precision Multimeter HM8112-3 Valid at 23 °C after a 30 minute warm-up period DC specifications Ranges: Input impedance 0.1 V, 1.0 V: 10 V, 100 V, 600 V: Accuracy: Range 0.1 V 1.0 V 10.0 V 100.0 V 600.0 V 0.1 V; 1 V; 10 V; 100 V; 600 V › 1 GΩ 10 MΩ Values given are in ±(% of reading (rdg.) + % of full scale (f.s.)) 1 year; 23 ± 2° C %rdg. %f.s. 0.005 0.0006 0.003 0.0006 0.003 0.0006 0.003 0.0006 0.004 0.0006 Temp. coefficient 10...21° C + 25...40° C 0.0008 0.0008 0.0008 0.0008 0.0008 0.1 sec 120.000 digit 60.000 digit 1 μV 1 to 60 sec 1,200.000 digit 600.000 digit 100 nV Integration time: Display range: 600 V range: Resolution: Zero point Temperature drift: Long-term stability: AC specifications Measurement ranges: Measurement method: better than 0.3 V/° C better than 3 μV for 90 days 0.1 V; 1 V; 10 V; 100 V; 600 V true rms DC or AC coupled (not in 0.1 V range) Input impedance: 0.1 V, 1 V: 1 GΩ II ‹ 60 pF 10 V, 100 V, 600 V: 10 MΩ II ‹ 60 pF Response time: 1.5 sec to within 0.1 % of reading Accuracy: For sine wave signals › 5 % of full scale. Values given are in ± (% of reading + % of full scale); 23 ± 2° C for 1 year Range 0.1 V 1.0 V 10.0 V 100.0 V 600.0 V Resistance Ranges: Integration time: Display ranges: Resolution: Accuracy: 20 Hz-1 kHz 1-10 kHz 10-50 kHz 50-100 kHz 100-300 kHz 0.1+0.08 5+0.5 (5kHz) 0.08+0.08 0.15+0.08 0.3+0.1 0.8+0.15 7+0.15 0.08+0.08 0.1+0.08 0.3+0.1 0.8+0.15 4+0.15 0.08+0.08 0.1+0.08 0.3+0.1 0.8+0.15 0.08+0.08 0.1+0.08 Temperature coefficient 10…21° C and 25…40° C; (% rdg. + % f.s.) at 20 Hz – 10 kHz: 0.01 + 0.008 at 10 kHz – 100 kHz: 0.08 + 0.010 Crest factor: 7:1 (max. 5 x range) Integration time: 0.1 sec 1 to 60 sec Display range: 120.000 digit 1,200.000 digit 600 V range: 600.00 digit 600.000 digit Resolution: 1 μV 100 nV Overload protection: (V/Ω-HI to V/Ω-LO) and to chassis: Measurement ranges: all all the time 850 Vpeak or 600 VDC Maximum input voltage LOW against chassis/safety earth: 250 Vrms at max. 60 Hz or 250 VDC Current specifications Ranges: Integration time: Display ranges: 1 A range: Resolution: Accuracy: (1 year; 23 ± 2 ° C) Temperature coefficient /°C: (%rdg. + %f.s.) Voltage: Response time: Crest factor: Input protection: 100 μA; 1 mA; 10 mA; 100 mA; 1 A 0.1 sec 1 to 60 sec 120.000 digit 1,200.000 digit 100.000 digit 1,000.000 digit 1 nA 100 pA DC 45 Hz – 1 kHz 1 kHz – 5 kHz 0.02 + 0.002 0.1 + 0.08 0.2 + 0.08 10...21° C 25...40° C 0.002+ 0.001 0.01+ 0.01 ‹ 600 mV to 1.5 V 1.5 sec to within 0.1 % of reading 7:1 (max 5 x range) fuse, FF 1 A 250 V Range 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ 0.1 sec 1 to 60 sec 120.000 digit 1,200.000 digit 1 mΩ 100 μΩ Values given are in ± (% of reading + % of full scale) 1 year; 23 ± 2° C %rdg. %f.s. 0.005 0.0015 0.005 0.001 0.005 0.001 0.005 0.001 0.05 0.002 0.5 0.02 Temp. coefficient /° C 10...21° C 25...40° C 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.002 0.002 0.01 0.01 Measurement current: Range 100 Ω, 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ max. measurement voltage: approx. 3 V Overload protection: 250 VP Current 1 mA 100 μA 10 μA 1 μA 100 nA Temperature measurement PT100 / PT1000 (EN60751): 2- and 4-wire measurement Range: –200° C to + 800° C Resolution: 0.01° C; measurement current 1 mA Accuracy: ± (0.05° C + sensor tolerance + 0.08 K) Temperature coefficient 10...21° C and 25...40° C: ‹ 0.0018° C/° C NiCr-Ni (K-type) Range: –270 °C to +1372 °C Resolution: 0.1 °C Accuracy: ± (0.7 % rdg. + 0.3 K) NiCr-Ni (J-type) Range: –210° C to +1200° C Resolution: 0.1 °C Accuracy: ± (0.7 % rdg. + 0.3 K) Frequency and period specifications Range: 1 Hz to 100 kHz Resolution: 0.00001 Hz to 1 Hz Accuracy: 0.05 % of reading Measurement time: 1 to 2 sec Interface Interface: Data rate: Functions: Inputs: Outputs: RS-232 (standard), IEEE-488 or USB (opt.) 9600 or 19200 Baud Control / Data fetch Function, range, integration time, start command Measurement results, function, range, integration time (10 ms to 60 sec.) Miscellaneous Time to change range or function approx. 125 ms with DC voltage, DC current, resistance approx. 1 sec with AC voltage, AC current Memory: 30,000 readings/128 kB Safety class: Safety class I (EN 61010) Power supply: 105-254 V~; 50/60 Hz Power consumption: approx. 8 W Operating temperature: +10° to +40° C Storage temperature: -40° to +70° C Max. relative humidity: ‹ 75% (without condensation) Dimensions (W x H x D): 285 x 75 x 365 mm Weight: approx. 3 kg Accessories supplied: Operator’s Manual, power cable, HZ15 PVC test lead, Interface cable Optional accessories: HZ887 Temperature sensor (PT100; -50° C to + 400° C), HZ42 19” Rackmount kit 2RU, HZ10S/R Silicone test lead, HO870 USB Interface, HO880 IEEE-488 interface, HO890 RS-232 Interface, HO112 Scanner Card (Installation only ex factory) w w w. h a m e g . co m HM8112-3E/150507/ce · Subject to alterations · © HAMEG Instruments GmbH · ® Registered Trademark · DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · [email protected] A Rohde & Schwarz Company
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement