Universal converter 9116B – Input for RTD, TC, Ohm, potentiometer, mA and V – Supply for 2-wire transmitters – Active / passive mA output and relay output – Can be supplied separately or installed on power rail, PR type 9400 – SIL 2-certified via Full Assessment Advanced features • Configuration and monitoring by way of detachable display front (PR 4501); process calibration, signal and relay simulation. • Advanced relay configuration, e.g. setpoint, window, delay, sensor error indication and power monitoring. • Copying of the configuration from one device to others of the same type via PR4501. • Reduced Uo Ex data < 8.3 V for active input signals. • TC inputs with internal CJC or external CJC for higher accuracy. • The device automatically detects whether it must supply an active or a passive current signal. Connection Application • 9116B can be mounted in the safe area and in zone 2 / cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I/II/III, Div. 1, Gr. A-G. • Conversion and scaling of temperature, voltage, potentiometer and linear resistance signals. • Power supply and signal isolator for 2-wire transmitters. • Monitoring of error events and cable breakage via the individual status relay and/or a collective electronic signal via the power rail. • The 9116 has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508. Technical characteristics • 1 green and 1 red front LED indicate operation status and malfunction. 1 yellow LED indicates relay status. • 2.6 kVAC galvanic isolation between input, output and supply. This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability Environmental Conditions Specifications range....................................... Storage temperature...................................... Calibration temperature................................. Relative humidity............................................ Protection degree........................................... Installation in.................................................. Output specifications -20°C to +60°C -20°C to +85°C 20...28°C < 95% RH (non-cond.) IP20 Pollution degree 2 & measurement / overvoltage category II Mechanical specifications Dimensions (HxWxD)..................................... Dimensions (HxWxD) w/ display 4501............................................................... Weight approx................................................ Weight incl. 4501 / 4511 (approx.)................. DIN rail type................................................... Wire size........................................................ 109 x 23.5 x 104 mm 109 x 23.5 x 116 mm 185 g 200 g / 285 g DIN EN 60715 - 35 mm 0.13...2.08 mm2 AWG 26...14 stranded wire Screw terminal torque.................................... 0.5 Nm Common specifications Supply voltage............................................... Fuse............................................................... Max. power consumption............................... Isolation voltage, test /working: Input to any.................................................... Analog output to supply................................. Status relay to supply..................................... Communications interface............................. Communications interface............................. Signal / noise ratio......................................... Response time (0...90%, 100...10%): Temperature input (programmable)............... mA / V input (programmable)......................... Auxiliary supplies for 9116B1: 2-wire supply (terminal 54...52)...................... Auxiliary supplies for 9116B2: 2-wire supply (terminal 54...52)...................... 19.2...31.2 VDC 1.25 A SB / 250 VAC ≤ 3.5 W 2.6 kVAC / 300 VAC reinforced isolation 2.6 kVAC / 300 VAC reinforced isolation 1.5 kVAC / 150 VAC reinforced isolation Programming front 4501 Modbus communication enabler 4511 Min. 60 dB (0...100 kHz) 1...60 s 0.4...60 s 28...16.5 VDC / 0...20 mA 22...16.5 VDC / 0...20 mA Input specifications Approvals EMC............................................................... EN 61326-1 LVD................................................................ EN 61010-1 ATEX.............................................................. KEMA 10ATEX0053 X IECEx............................................................. KEM 10.0022X cFMus............................................................ 3038267-C UL................................................................... UL 61010-1 GOST R......................................................... Yes GOST Ex........................................................ Yes DNV Marine.................................................... Stand. f. Certific. No. 2.4 SIL 2............................................................... PREl 070902 P0002 C05 SIL 2............................................................... Certified & Fully Assessed acc. to IEC 61508 9116B-083013 RTD input....................................................... Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000 Cable resistance per wire (max.), RTD.................................................... 50 Ω Sensor current, RTD...................................... Nom. 0.2 mA Effect of sensor cable resistance (3-/4-wire), RTD............................................. < 0.002 Ω / Ω Sensor error detection, RTD.......................... Programmable ON / OFF Short circuit detection, RTD........................... Yes TC input: Thermocouple type......................... B, E, J, K, L, N, R, S, T, U, W3, W5, LR Cold junction compensation (CJC) via ext. sensor in connector 5910.............................................. 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C CJC via internally mounted sensor............................................................ ±(2.0°C + 0.4°C * Δt) Δt =................................................................. internal temperature-ambient temperature Sensor error detection, TC............................. Programmable ON or OFF (only wire breakage) Current input: Measurement range.............................................................. 0...20 mA Current input: Programmable measurement ranges..................................... 0...20 and 4...20 mA Input resistance, current input............................................................... Nom. 20 Ω + PTC 50 Ω Sensor error detection, current...................... Loop break 4...20 mA Voltage input: Measurement range.............................................................. 0...10 VDC Programmable measurement ranges, VDC................................................................ 0/0.2...1, 0/1...5, 0/2...10 VDC Input resistance, voltage input............................................................... Nom. >10 MΩ Current output: Signal range......................... 0...20 mA Programmable signal ranges......................... 0...20 / 4...20 / 20...0 and 20...4 mA Load (max.).................................................... 20 mA/600 Ω/12 VDC Load stability, current output.......................... ≤0.01% of span/100 Ω Sensor error detection, current output............................................................. 0 / 3.5 / 23 mA / none NAMUR NE 43 Upscale/Downscale.............. 23 mA / 3.5 mA Output limitation, on 4...20 and 20...4 mA signals.................................... 3.8...20.5 mA Output limitation, on 0...20 and 20...0 mA signals.................................... 0...20.5 mA Current limit.................................................... ≤ 28 mA 2-wire 4…20 mA output: External 2-wire supply range........................................ 3.5...26 VDC Signal range................................................... 4…20 mA Max. load resistance [Ω]................................ (Vsupply - 3.5) / 0.023 A Load stability, 4…20 mA output..................... ≤ 0.01% of span / 100 Ω Effect of external 2-wire supply voltage variation................................. < 0.005% of span / V Relay output: Relay functions........................ Setpoint, Window, Sensor error, Power and Off Hysteresis, in % of span/display range.............................................................. 0.1...25 / 1...25 ON and OFF delay......................................... 0...3600 s Sensor error reaction..................................... Break / Make / Hold Max. voltage................................................... 250 VAC / 30 VDC Max. current................................................... 2 AAC / 2 ADC Max. AC power.............................................. 500 VA / 60 W Max. voltage, status relay.............................. 110 VDC / 125 VAC Max. current, status relay............................... 0.3 ADC / 0.5 AAC Max. AC power, status relay.......................... 62.5 VA / 32 W *of span.......................................................... = of the currently selected measurement range
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement