RAB Lighting ALED, Lightcloud Series Lighting System Installation Instructions
Advertisement
Advertisement
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
IMPORTANT
ALED with Universal Arm
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
MOUNTING THE UNIVERSAL ARM ON
THE FIXTURE
1. Remove the Arm Cover from the Arm.
2. Feed wires from Fixture through Gasket into Arm.
3. Line up Arm and Fixture. Place flat washers, lock washers and nuts on the Short 3/8-16 bolts inside the Arm and tighten securely to housing.
4. Make sure the Gasket is secure between Arm and
Fixture.
Arm
Arm Gasket
Arm Cover
Gasket
FIG. 1
Fixture
SQUARE POLE BRACKET MOUNT
1. Remove Round pole adaptor and RPA gasket.
2. Place the Bolster plate inside the pole..
3. Place the bracket to match the holes on the pole
4. Feed supply wires from the pole through the Bracket to be connected to the Arm.
3. Place flat washers, lock washers and nuts on the Short
3/8-16 bolts tighten to the pole.
Bolster Plate
Square Pole
FIG.2
Short 3/8” bolts
ROUND POLE BRACKET MOUNT
1. Place Round Pole Adaptor (RPA) and RPA Gasket between the fixture and drilled Pole as shown in Fig.3.
2. Line up the holes of the Gaskets and Round Pole
Adaptor with top hole in the pole drilling pattern.
3. Feed supply wires from the pole through the Bracket to be connected to the Arm.
4. Place long 3/8” Bolts provided through the top hole of the RPA and Gaskets to the Round Pole thread into
Bolster Plate.
Bolster Plate
Round Pole
RPA Gasket
Round Pole Adaptor(RPA)
Bracket
Long 3/8” bolts
FIG.3
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
MOUNTING FIXTURE TO THE POLE
1. Remove the Arm Cover from the Arm.
2. Feed supply wires which are already pulled out from the pole through the bracket into the Arm.
3. Make necessary connections inside the Arm and knot wires for strain relief.
4. Slide the metal hanger plates at the back of the Arm to the mounting hooks of the bracket on the pole,to secure the fixture to the pole.
5. Replace the Arm Cover. Be sure the Gasket on Arm
Cover is in place. Tighten Screws and add the Plugs.
Secure Pole cap. Tighten Set screw at the bottom of the arm.
ON-OFF WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. Units ordered with (/480V) suffix are 480V, 60Hz.
For Non-Dimming, follow the wiring directions as in fig. 5
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground.
(+)LINE BLACK
(-)COMMON WHITE
GROUND GROUND
LIGHT
FIXTURE
Pole (Not provided)
FIG.5
Fixture
Bracket
Close up
Arm
Arm Cover Gasket
Arm Cover screw
Plug
PHOTOCELL INSTALLATION
Wire the photocell as shown below.(Fig.6)
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
BLACK
LIGHT
FIXTURE
FIG.6
Metal Hanger plates
Mounting Hooks
FIG.4
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
0-10V DIMMABLE WIRING WITH
WATTSTOPPER SENSOR
Universal voltage driver and Wattstopper Sensor permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10V Dimming with Wattstopper, follow the wiring directions (Fig.7)
1. Connect the black fixture lead to the LOAD of
Wattstopper Sensor.
2. Connect LINE of Wattstopper Sensor to LINE supply lead.
3. Connect the white fixture lead and NEUTRAL of
Wattstopper Sensor to the COMMON supply lead.
4. Connect the GROUND wire from fixture and Wattstopper
Sensor to supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
5. Connect the purple fixture lead to DIM + of Wattstopper
Sensor.
6. Connect the gray fixture lead to the DIM - of Wattstopper
Sensor lead.
7. Cap the yellow fixture lead, if present. Do NOT connect.
DIMMABLE WIRING DIAGRAM
LED
Dimmable
Driver
NEUTRAL
LOAD
GRAY (-)
VIOLET (+)
14-18 AWG Solid CU Wire Only
FSP-211
High/Low PIR
Occupancy Sensor
230 VAC, 50 Hz
1200W max ballast
18-20 AWG Solid CU Wire Only
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open fixture to clean the LED. Do not touch the
LED.
FIG.7
POLE DRILLING DETAIL
Dimensions of the holes on RPA and Bracket.
This template is not to scale. Please use measurements shown in Fig.8.
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
2. Be sure the fixture is grounded properly.
3. Is the photocell, if used, functioning properly?
ACCESSORIES
•
LALED150-Door Lens replacement
Avaiable in Bronze, (W)White, (RG)Gray
•
GOALED150W-Wire Guard
Available in (G)Grey
FIG.8
Patent: US: pat. D668,370
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Easy Answers
© 2017 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
ALED IN 0717
rabweb.com
Visit our website for product info
Tech Help Line
Call our experts - 888 722-1000
Answered promptly - [email protected]
Free Lighting Layouts
Answered online or by request
R
ALED SLIPFITTER 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
MOUNTING FIXTURE
1. The Slipfitter fits a 2 3/8” O.D. Tenon. Place the slipfitter over the tenon and secure the fixture with 2 Set Screws on the side of the slipfitter.
2. Feed wires from Fixture through slipfitter and supply wires from Pole. Make the necessary connections in the slipfitter and knot wires for strain relief.
3. To adjust the angle of the slipfitter, remove 2 screws and remove the Slipfitter Cover Plate. Loosen the Locking
Bolt and swivel fixture to desired angle. The graduation on the slipfitter cover plate can be used as guidelines to adjust the angle.
4. Tighten the Locking Bolt. Replace slipfitter cover plate.
Tighten Screws and close the Plug.
5. Seal Plug using Teflon tape or silicone sealant.
Screws
Plug
Fixture
Slipfitter
Locking Bolt
Tenon
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open fixture to clean the LED. Do not touch the
LED.
TROUBLESHOOTING
1. Check that the line voltage at fixture is correct. Refer to wiring directions.
2. Is the fixture grounded properly?
3. Is the photocell functioning properly (if used)?
R
ALED SLIPFITTER 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
ON-OFF WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. Units ordered with (/480V) suffix are 480V, 60Hz.
For Non-Dimming, follow the wiring directions as in fig. 1.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground.
(+)LINE BLACK
(-)COMMON WHITE
GROUND GROUND
LIGHT
FIXTURE
Fig. 1
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. For 0-10V Dimming, follow the wiring directions as in fig. 2.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to the output.
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.
PHOTOCELL INSTALLATION
Photocell may be installed in the field. Apply weatherproof silicone sealant to all plugs and unused conduit entries.
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
Fig. 2
BLACK
PHOTOCELL
PHOTOCELL
RAB fixture designs are protected under U.S. and International Intellectual Property laws.
Patents: US: pat. D587,839; CN: ZL200830272893.0; MX: 28396, TW: pat. 96304793-U02; CA: D RAB Lighting, Inc
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Easy Installation & Product Help
©2013 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
ALEDSF IN 0114
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
Answered promptly [email protected]
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
ALED260/ 360
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
CAUTION: The fixture weighs 80lbs. Make sure pole and hardware supplied by others (if any) can withstand the weight of the fixture.
MOUNTING ARM ON FIXTURE
1. Remove the Arm Cover from the Arm.
2. Feed wires from Fixture through Gasket into Arm.
3. Line up Arm and Fixture. Place flat washers, lock washers and nuts on the Short 3/8-16 bolts inside the Arm and tighten securely to housing.
4. Make sure the Gasket is secure between Arm and
Fixture.
Arm
Short 3/8”
Bolts
Gasket
Fixture
MOUNTING FIXTURE DIRECTLY TO
POLE
Check that pole is drilled according to Pole Drawing Detail.
1. Remove the Arm Cover from the Arm.
2. Feed wires from Fixture through Gasket into Arm. Feed supply wires from Pole through Gasket into Arm.
3. Insert Long 3/8-16 bolts through Arm, Gasket, Pole and thread into the Bolster Plate. Be sure the Gasket is between the Arm and pole and secure with bolts, washers and lockwashers.
4. Make necessary connections inside the Arm and knot wires for strain relief.
5. Replace the Arm Cover. Be sure the Gasket on Arm
Cover is in place. Tighten Screws and add the Plugs.
Secure Pole cap.
Pole Cap
Gasket
Short 3/8” Bolts
Screws (2)
Plugs (2)
Arm Cover
Arm
Long 3/8” Bolts
Bolster
Plate
Plugs (2)
Screws (2)
Arm Cover
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
ROUND POLE ADAPTOR ACCESSORY
For use with standard RAB pole drilling.
1. Drill round pole using the dimensions shown in the Pole
Drilling Detail.
2. Place Round Pole Adaptor/ RPA (Ordered separately) and RPA Gasket between the fixture and drilled Pole as shown.
3. Line up top holes of the Gaskets and Round Pole
Adaptor with top hole in the pole drilling pattern.
4. Place long 3/8” Bolts from the ALED through the top hole of the RPA and Gaskets to the Round Pole thread into Bolster Plate.
5. Feed wires from Fixture through Gasket into Arm. Feed supply wires from Pole through Gasket into Arm. Make necessary connections inside the Arm and knot wires for strain relief.
6. Replace the Arm Cover, tighten Screws and add the
Plugs. Secure Pole cap.
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. 0-10V control wires must be rated for 300V minimum. Units ordered with (/480) suffix are 480V, 50 or
60Hz. For 0-10V Dimming, follow the wiring directions as shown in figure below.
1. Connect the black fixture lead to the LINE supply lead.
2. Connect the white fixture lead to the COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to the output.
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.
Round Pole Adaptor (RPA) - Ordered separately
Bolster Plate
Arm Gasket
Round Pole
(not supplied)
RPA
Gasket
Plugs (2)
Screws (2)
Arm Cover
Long 3/8” Bolts
PHOTOCELL INSTALLATION
Photocell may be installed in the field. Apply weatherproof silicone sealant to all plugs and unused conduit entries.
1. Knockout hole on top of arm.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
BLACK
PHOTOCELL
PHOTOCELL
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
POLE DRILLING DETAIL
For non-RAB poles use these dimensions to drill the pole.
This template is not to scale. Please use measurements shown.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open fixture to clean the LED. Do not touch the
LED.
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
2. Be sure the fixture is grounded properly.
3. Is the photocell, if used, functioning properly?
Patent: US: pat. D668,370
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Easy Installation & Product Help
©2016 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
Answered promptly [email protected]
ALED 260 360 IN 0616
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
ALED260/ 360 with Slipfitter
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
CAUTION: The fixture weighs 80lbs. Make sure pole and hardware supplied by others (if any) can withstand the weight of the fixture.
MOUNTING FIXTURE
1. The Slipfitter fits a 2 3/8” O.D. Tenon. Place the slipfitter over the Tenon and secure the fixture with Set Screws
(2) on the side of the Slipfitter.
2. Feed wires from Fixture through Slipfitter and supply wires from pole (not supplied). Make the necessary connections in the Slipfitter and knot wires for strain relief.
3. To adjust the angle of the Slipfitter, remove Screws
(2) and remove the Slipfitter Cover Plate. Loosen the
Locking Bolt and swivel fixture to desired angle. The graduation on the Slipfitter Cover Plate can be used as guidelines to adjust the angle.
4. Tighten the Locking Bolt. Replace Slipfitter Cover Plate.
Tighten Screws.
5. Apply weatherproof silicone sealant and tighten Plug.
Fixture
Screws (2)
Plug
Slipfitter
Cover
Plate
Slipfitter
Locking Bolt
Tenon
(supplied by others)
Set screws
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. 0-10V control wires must be rated for 300V minimum. Units ordered with (/480) suffix are 480V, 50 or
60Hz. For 0-10V Dimming, follow the wiring directions as shown in figure below.
1. Connect the black fixture lead to the LINE supply lead.
2. Connect the white fixture lead to the COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to the output.
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open fixture to clean the LED. Do not touch the
LED.
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
2. Be sure the fixture is grounded properly.
3. Is the photocell, if used, functioning properly?
Patent: US: pat. D668,370
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Easy Installation & Product Help
©2016 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
Answered promptly [email protected]
ALEDSF 260 360 IN 0616
Lightcloud is a commercial wireless lighting control system
& service. It’s powerful and flexible, yet easy to use and install. Learn more at
lightcloud.com
1 (844) LIGHTCLOUD
1 (844) 544-4825 [email protected]
Custom manufactured in China
© RAB Lighting, Inc
170 Ludlow Avenue Northvale, NJ 07647
Welcome
Sensor
LCSENSE15/D10 (Ceiling Sensor)
LCHBSENSE15/D10 (High Bay Sensor)
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
1 (844) 544-4825 [email protected]
Hello
Lightcloud is a wireless lighting control service.
The Lightcloud Sensor is a remotely configurable passive infrared motion sensor that can switch and dim both hardwired circuits and remote circuits using
Lightcloud Controllers.
Product Features
Advanced PIR Sensing
Secure Cloud Control & Configuration
Retrofit-Friendly Local Control
Scheduling & Astronomical Clock
Temperature Monitoring
Light Sensor
Power Monitoring
0-10V Dimming
Patent Pending
Contents
Lightcloud Ceiling Sensor or High Bay Sensor
Wire Nuts x 4 x 2
Accessories
For use with High Bay Sensor Only
Lens Cover for 180°
Coverage (included)
Arm (optional, includes
2 screws and 1 locknut)
Instruction Manual
Height Adjuster
(optional, must use in conjunction with Arm)
Specifications
Indoor Damp Location
PART NUMBER
LCSENSE15/D10 (Ceiling)
LCHBSENSE15/D10 (High Bay)
OPERATING HUMIDITY
10% RH to 95% RH
Non-Condensing
INPUT
120-277VAC, 50/60Hz,
<1W (Standby) - 2W (Active)
MAXIMUM SWITCHED LOAD RATINGS
Electronic Ballast: 277VAC, 3300W
Magnetic Ballast: 277VAC, 1200W / 120VAC, 800W
Tungsten: 220VAC, 3000W
Dimming: 0-10V (Class2)
OPERATING TEMPERATURE
-20ºC to 40ºC
OVERALL DIMENSIONS
4.91” Diameter, 1.61” Height
WIRELESS RANGE
Line-of-Sight: 1000 feet
Obstructions: 100 feet
Warranty is active as long as service plan is active.
What You Need
Lightcloud Gateway
A Lightcloud installation requires at least one Lightcloud Gateway to manage your devices.
Setup & Installation
1
Find a suitable location
Use these guidelines when installing devices:
• If there is a clear line of sight between two Lightcloud devices,
they can be placed up to 1000 feet apart.
• If the two devices are separated by ordinary drywall construction,
try to keep them within 100 feet of each other.
• Brick, concrete and steel construction may require additional
Lightcloud devices to go around the obstruction.
Add an additional Lightcloud
Device to extend network range around corners
D RY WA LL
O R S IMIL A R
Lightcloud Gateway
<= 100 ft.
B RICK ,
CO N CRE TE O R
ME TA L WA LL
2
Install your Lightcloud Sensor
INSTALL AT A JUNCTION BOX (INDOOR/OUTDOOR)
The Sensor can control other Lightcloud devices, wirelessly.
If you don’t need to hard-wire a switched circuit to the Sensor, no problem—just tie the white/red wire to neutral and cap off any unused wires.
Sensor attached attached to wired junction box
Setup & Installation
(cont’d)
3
Installing Accessories (High Bay only)
Arm: mount sensor to fixture using ½” NPS threaded nipple
Extruded Tube
SET SCREW
LOCKNUT
ARM
SENSOR
½” NPS THREADS
Height Adjuster: adjust height by loosening set screw, moving sensor up or down along extruded tube, then tightening set screw. Ensure sensor lens is not blocked by any part of the fixture.
4
Wiring
Panel
SWITCHED NEUTRAL
The “Switched Neutral” white with red stripe wire is the neutral line for the load being switched. This enables power measurement. See the Power Measurement section under
“Functionality” for more information.
WHITE/RED
RED
WHITE
BLACK
Load
WHITE
BLACK
GRAY
PURPLE
0-10V
DIMMING
!
This product should only be installed by a qualified electrician and in compliance with local and national electrical codes.
Setup & Installation
(cont’d)
5
Labeling your device
DEVICE IDs
ZONE NA ME
PANEL /
CIRCUIT #
For setup and maintenance, we provide two Lightcloud Device Tables with the Gateway: one that you can attach to your panel and one to hand off to a building manager. Attach the Device Identification stickers included with each device to a row, then write in additional information, such as Zone name, Panel/Circuit Number, and whether or not a zone uses dimming.
6 Power up
To add new devices to your Lightcloud network, contact RAB:
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
or 1 (844) 544-4825 [email protected]
7
Confirm device connectivity
Confirm status indicator LED (see step 8) is solid green. If it is not, make sure your device is within range of another Lightcloud AC-powered device.
8
Setup & Installation
(cont’d)
Place cover
Secure cover onto sensor by pushing up and twisting to the right (clockwise).
STATUS
INDICATOR
9
Commission & Configure Your Devices
All Lightcloud products can be commissioned and configured by:
• Logging on to lightcloud.com
• Calling RAB at 1 (844) LIGHTCLOUD
• Emailing us at [email protected]
Functionality
Overview
LIGHT
SENSOR
SENSOR
STATUS INDICATOR
SIGNAL
INDICATOR
POWER
INDICATOR
DEVICE
BUTTON
MOTION
INDICATOR
STATUS INDICATOR:
• Solid GREEN when connected to your Lightcloud network
• Blinking RED when not connected to a Lightcloud network. The device will
automatically continue trying to connect to a network that is in Setup Mode.
POWER INDICATOR:
Illuminated when powered. Blinking when indicated from the Lightcloud application.
SIGNAL INDICATOR:
After the Device Button has been pressed, this indicator illuminates when the device receives a message and indicates the strength of the signal.
3 - Best Signal
2 - Acceptable Signal
1 - Unacceptable Signal
Consult the “Finding a Location” section for more information.
DEVICE BUTTON:
• Press once to highlight this device in the Lightcloud Application
(pressing once also enables display of the Signal Indicators)
• Press twice to toggle circuit on and off
• Press twice and hold to set dim level
• Press and hold for 10 seconds to remove this device from a Lightcloud network
MOTION INDICATOR:
Illuminates when motion is detected
SENSOR:
Passive-infrared motion sensor
Functionality
(cont’d)
Features: Passive Infrared Motion Detection
CEILING SENSOR HIGH BAY SENSOR
9’
15’ 7.5’ 0’
SIDE VIEW
7.5’ 15’
30’
20’ 14’ 0’
SIDE VIEW
14’ 20’
15’
7.5’
20’
14’
0’
0’
7.5’
30’
40’
14’
20’
15’
TOP VIEW
TOP VIEW
Features
OCCUPANCY & VACANCY SENSING:
The Lightcloud Sensor can operate in either Occupancy or Vacancy Sensor modes, selectable via the Lightcloud application. In Occupancy mode, the attached circuit will be switched on when motion is detected, and off (or dimmed) when the timeout expires. In Vacancy mode, the attached circuit will be turned off when the motion timeout expires, but will only be turned on via the Lightcloud application,
Lightcloud Wall Switch, or similar. Motion detection and timeout can still be used via Lightcloud Automations to control other devices.
CONTROLLER MODE:
In Controller Mode, the attached circuit is controllable as an independent zone in the Lightcloud application. Motion detection and timeout can still be used via
Lightcloud Automations to control other devices.
RANGE TEST MODE:
When Range Test Mode is activated via the Lightcloud application, the timeout period is shortened so that you can test different sensitivities quickly. All indicators will go off except for the Motion Indicator. When satisfied, turn off Range Test
Mode to continue normal operation.
Functionality
(cont’d)
Features
0-10V DIMMING:
0-10V is a common method of low-voltage control of dimmable drivers and ballasts.
Purple: 0-10V positive | Gray: 0-10V common
Note: The National Electrical Code requires that low-voltage wiring used in the same enclosure as high voltage wiring have an equal or better insulation rating. You may need to complete your low-voltage wiring in another enclosure or use a partition.
DEVICE IDENTIFICATION:
For help with installation, there are two ways to identify this device:
• Pressing the Device Button on the actual product will produce a message in
the Lightcloud application indicating which device you are working with.
• Pressing the “Indicate” button in the Lightcloud application will cause the
device’s Status Indicator to blink green. This will also switch the device’s relay
on and off repeatedly, allowing you to quickly identify which circuit it is.
POWER MEASUREMENT:
The Lightcloud Sensor is capable of measuring the power usage of the attached circuit. In order to utilize this function, the neutral wire of the load must be connected to the white-red switched neutral wire. If this wire is not used, it should be tied to the regular neutral wire (i.e. all neutral wires joined).
POWER LOSS DETECTION:
If power to the Sensor is lost, the device will detect this and alert the
Lightcloud application.
EMERGENCY DEFAULT:
If communication is lost, the Sensor may optionally fall back to a specific state, such as turning the attached circuit on. This may be configured via the
Lightcloud application or by calling RAB.
FCC Information:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This device has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 Subpart B, of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
To comply with the FCC's RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
CAUTION: Changes or modifications to this equipment not expressly approved by RAB Lighting may void the user’s authority to operate this equipment.
Manual
®
Device Specifications
PART NUMBER
LCGATEWAY
ELECTRICAL
The Lightcloud Gateway is designed to be hard-wired to AC power by a qualified electrician.
INPUT
120-277 VAC, 50/60 Hz
60-45mA
BATTERY
Li-ion battery. Contact RAB only for replacement batteries.
CAUTION! RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT
TYPE. DISPOSE OF USED BATTERIES ACCORDING TO LOCAL LAWS.
Some communities offer recycling or collection of rechargeable batteries— contact your local government for disposal practices in your area.
DISCONNECT
An external readily accessible disconnect device, such as a circuit breaker, is required.
Custom manufactured in China
Copyright © 2016 RAB Lighting, Inc.
Contents
7
8
5
6
Introduction
System Overview
Lightcloud Gateway
Lightcloud Devices
9
10
11
12
Finding a Suitable Location
Best Practices
Best Practices
Getting Started
13
14
17
Installation
Lightcloud Gateway
Lightcloud Devices & Table
18
18
18
18
Setup
Network Setup
Gateway Activation
Lightcloud Devices
3
4
Welcome to lighting control that just works.
Lightcloud is a cloud-based wireless lighting control system that makes it easy to take charge of your lighting—from sensing to dimming, schedules to scenes, and everything in between.
Control and configure your system remotely using the Lightcloud Application, or call RAB to have our experts set up your system just how you need it.
5
6
System Overview
An individual Lightcloud installation, or Site, requires at least one Lightcloud
Gateway depending on the environment and usage. Your Lightcloud devices communicate with each other and the Gateway via a wireless mesh network, which allows site layout to be flexible and robust.
The Lightcloud Gateway and Devices require a subscription to function beyond the installation period. Call RAB at
1 (844) LIGHTCLOUD or
visit lightcloud.com to set up your account. Your Lightcloud subscription gets you these state-of-the-art features:
• Online control & configuration at control.lightcloud.com
• Device commissioning
• Free support
• Telephone concierge
• Energy monitoring
Lightcloud Gateway
The Gateway connects your system to our secure, private server via a cellular signal, so you don’t have to worry about providing your own internet connection. With the
Gateway powered and connected, your
Lightcloud site is at your command with the
Lightcloud Application. For maximum security, the Gateway isn’t exposed to the internet at all, and for maximum reliability, the Gateway contains an Uninterruptible Power Supply (UPS) that will maintain power for up to 2 hours.
When the Gateway is not powered or available, switching devices such as the Controller will fall back to a configurable emergency mode, such as turning on to full brightness.
Lightcloud Gateway
7
8
Lightcloud Devices
LIGHTCLOUD DEVICES THAT CONNECT TO THE GATEWAY
Lightcloud Controller
The Controller switches circuits up to 20A as well as provides a 0-10V dimming interface for dimmable drivers and ballasts.
Lightcloud Ceiling Sensor
The Ceiling Sensor is an intelligent passive infrared motion sensor that can be configured for both occupancy and vacancy sensing. Switches up to 15A and provides 0-10V dimming.
Lightcloud Daylight
The Daylight is an innovative, self-powered daylight harvesting sensor that measures available light and adjusts your lighting automatically.
Lightcloud Dimmer
The Wall Dimmer puts advanced control at your fingertip. Configure via the
Lightcloud App to switch & dim a zone or change scenes.
Lightcloud Devices
Learn more about Lightcloud Devices at lightcloud.com
Finding a Suitable Location
The Gateway should be installed in a dry or non-condensing damp environment only.
Use these guidelines when installing additional Lightcloud devices:
• If there is a clear line of sight between two devices, they can be
placed up to 1000 feet apart.
• If the two devices are separated by ordinary drywall construction,
try to keep them within 100 feet of each other.
• Brick, concrete and steel construction may require additional
devices to go around the obstruction.
Finding a Suitable Location
9
Best Practices
Unlike an ordinary WiFi router, where all devices must be within range of the router, hardwired Lightcloud devices extend the range of the network—so as long as each device is within range of another, you’ll have a strong, reliable system.
NOTE
: Lightcloud Daylight devices do not
extend the range of a Lightcloud network.
PROBLEM M ATERIALS
M E TA L C O N C R E T E B R I C K
Large amounts of metal, concrete and brick are bad news for radio signals; in some cases, you’ll have to go around these obstacles with additional AC-powered Lightcloud devices.
10
Best Practices
Add an additional Lightcloud
Device to extend network range around corners
DRY WALL
OR SIMIL AR
Lightcloud Gateway
<= 100 ft.
BRICK ,
CONCRETE OR
METAL WALL
Best Practices (Continued)
Lastly, consider sources of invisible interference.
Avoid placing Lightcloud devices near microwaves, motors (especially elevator mechanical rooms) or any other radio amplifiers and antennas.
PROBLEM DEVICES & SIGNALS
M I C R O WAV E S
E L E VATO R M E C H A N I C A L R O O M S
A M P L I F I E R S & A N T E N N A S
Best Practices
11
Getting Started
INSIDE YOUR GATEWAY
ACTIVATION STEPS
G ATE WAY
DEVICE TABLE
DEVICE ID ZONE NAME
PANEL/
CIRCUIT # PWR/ENGY
DIM NOTES
MANUAL
Manual
®
12
CONTAINS
2x Wire Nuts
2x Mounting Screws
4x Device ID Labels
1x Power Cable*
Getting Started
*The Lightcloud Gateway must be mains powered for permanent installation. Power cord
including for testing cellular signal strength at different locations in a facility.
CELLULAR SIGNAL STRENGTH
Installation
The Lightcloud Gateway is rated 120-277VAC and contains an integral junction box for hard-wired installation by a qualified electrician.
POWER
CELLULAR SIGNAL STRENGTH
SYSTEM STATUS
LED Indicators
P OWER
Green: Fully powered
CELLUL AR
Off: No or poor cellular signal. You must move the Gateway to a location with better cellular signal.
Solid Yellow: Adequate cellular signal. This signal strength works for most applications, but if possible, move to a location with better signal.
Solid Green: Good cellular signal.
S YS TEM S TATUS
Blinking Yellow: Initializing
Solid Yellow: Error: Cannot reach Lightcloud service. Check Cellular Signal Strength and call RAB for technical support.
Blinking Green: Ready to connect with new
Lightcloud devices
Solid Green: Normal operation
Installation
13
Installing the Lightcloud Gateway
Follow instructions and steps to successfully install your Gateway.
1
STEP ONE
2
STEP T WO
WARNING
OFF
3:14
Choose a location with good cellular signal. Check your phone’s signal for reference.
NOTE : Locations with significant
concrete and brick construction, or underground locations, are not recommended. Do not install inside metal enclosures.
OFF
Turn off the breaker and prepare the circuit you’ll use to power the
Gateway. A dedicated circuit is recommended.
14
Installation Lightcloud Gateway
3
STEP THREE
Remove a knockout (KO) from the Gateway using a flat-blade screwdriver and hammer. Place the screwdriver blade at the edge of the
KO, then tap the screwdriver with the hammer to weaken the attachment. Work your way around the edge of the
KO until it breaks away.
4
STEP FOUR
5
STEP FIVE
6
STEP SIX
ON
ON
Mount the Gateway to the installation surface using size
10 screws appropriate for the surface material. For direct installation onto an external junction box, use the junction box’s included screws.
NOTE : Conduit must be used to
connect to side knockouts.
Install included battery with negative (-) end facing towards junction box area. Call RAB to request replacement rechargeable batteries.
Use RAB-provided batteries only.
Connect hot and neutral wires with included wire nuts.
Turn breaker back on.
Installation Lightcloud Gateway
15
Installing Lightcloud Gateway (Continued)
7
STEP SEVEN
8
STEP EIGHT
9
STEP NINE
DEVICE ID ZONE NAME
PANEL/
CIRCUIT # PWR/ENGY
DIM NOTES
2
1
GATEWAY DEVICE IDs
3
Turn on the Gateway main power switch. Replace outer cover and use included screws to secure.
16
When all devices are installed and powered, you’re ready to call RAB to activate and verify your system, and complete your site’s configuration.
NOTE : Use only RAB-
authorized parts.
Installation Lightcloud Gateway
Confirm that the cellular signal strength LED is yellow or green. If the
Gateway is powered but this LED is not lit, relocate the Gateway to an area with better reception.
You can use the included power cable to easily test the signal strength in a few locations, but remember that the Gateway must be hardwired for permanent installation.
Place extra Device ID stickers on your
Lightcloud Device Table (see page 18) for future reference.
For each device, find the number from the panel board and write it down on the Device Table.
Lightcloud Devices
Lightcloud devices that are mains hard-wired powered are designed to be installed on a junction box or similar enclosure, and must be installed by a qualified electrician. Refer to your device’s manual for installation considerations and best practices.
TIP:
Use extra Device ID stickers on or near your devices or circuits for easier identification.
Lightcloud Device Table
The Device Table is essential for referencing during setup or for troubleshooting—don’t forget it! Two copies are provided: one to keep near your Gateway, and one for the building owner or facility manager to file.
IN THE BOX MOUNT IT
Mount device table to breaker box.
HOW TO USE IT
Place Gateway ID sticker at the top.
DEVICE ID ZONE NAME
PANEL/
CIRCUIT # PWR/ENGY
DIM NOTES
GATEWAY ID:
PWR/ENGY
: if a zone uses the Controller’s integrated power monitoring, place a checkmark.
DIM
: if a zone uses the Controller’s 0-10V dimming wires, place a checkmark here.
Lightcloud Devices and Table
17
Setup
Gateway Activation
When you power your Gateway and it shows sufficient cellular signal
(solid yellow or green LED), call 1 (844) LIGHTCLOUD or 1 (844)
544-4825 to activate it and complete the rest of your site setup.
Network Setup
To add new devices to your Lightcloud network, call RAB at
1 (844)
LIGHTCLOUD.
Software Setup
Lightcloud is cloud-based—no software to install or maintain, ever.
Once you have a Lightcloud account, you can login to lightcloud.com at any time to configure and control your system.
Full Service
Need to change something about your system? No need to log in—
RAB can do it for you! Call 1 (844) LIGHTCLOUD and our support specialists will get you where you want to be.
18
Setup
FCC Information:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This device has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15
Subpart B, of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To comply with the FCC’s RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
CAUTION: Changes or modifications to this equipment not expressly approved by RAB Lighting may void the user’s authority to operate this equipment.
19
Lightcloud is a commercial wireless lighting control system
& service. It’s powerful and flexible, yet easy to use and install. Learn more at
lightcloud.com
1 (844) LIGHTCLOUD
1 (844) 544-4825
Welcome
© RAB Lighting, Inc
170 Ludlow Avenue Northvale, NJ 07647
Custom manufactured in China
Dimmer
LCDIMMERW
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
or 1 (844) 544-4825
Hello
Lightcloud is a wireless lighting control service.
The Lightcloud Dimmer is an in-wall switch that connects wirelessly to a
Lightcloud Controller to provide switching, dimming and scene control.
Product Features
Wireless Control & Configuration
Zone Switching & Dimming
Dim Level Indicator
Scene Selection
Nightlight
Contents
Dimmer
Faceplate Bracket
2x 6-32 1/2” Screws
Faceplate
Instruction Manual
2x 6-32 5/16” Screws
Specifications
PART NUMBER
LCDIMMER/W
INPUT
120-277VAC, 50/60Hz, 2W
OPERATING TEMPERATURE
0ºC to 40ºC
DIMENSIONS
Dimmer: 1.77”W x 2.7”H x 1.49”D
Faceplate: 2.94”W x 4.69”H x 0.06”D
Faceplace Bracket: 2.8”W x 4.55”H x 0.13”D
18AWG grounding; terminals supporting up to 12AWG wire
WIRELESS RANGE
Line-of-Sight: 1000 feet
Obstructions: 100 feet
What You Need
A Lightcloud Gateway
Wiring
WHITE / NEUTRAL
BLACK / HOT
GREEN / GROUND
PANEL
A Ceiling Sensor
(Or similar actuator)
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
or 1 (844) 544-4825
CAUTION
• Use only copper wire.
• Do not operate with the faceplate removed.
• This product should only be installed by a
qualified electrician and in compliance with
local and national electrical codes.
• This product should only be installed in a
UL-approved single gang wall-box enclosure.
• Indoor use only.
Finding a suitable location
Lightcloud uses a wireless mesh network to connect devices such as the Dimmer to the
Gateway. Unlike a WiFi router, each Lightcloud device may connect another device to the network. If there is a clear line of sight between two Lightcloud devices, they can be placed up to 1000 feet apart. If the two devices are separated by ordinary drywall construction, try to keep them within 100 feet of each other.
Brick, concrete and steel construction may require additional AC-powered Lightcloud devices to go around the obstruction. See the Deployment section of your Gateway for more information.
Setup & Installation
1
Turn off power
WARNING
OFF
OFF
Setup & Installation
(cont’d)
2
Install the Lightcloud Dimmer
2a
Screw the line (black) and neutral (white) wires into the labeled connectors on the back of the Dimmer. Connect the ground wire (green).
2b
Use the two 6-32 1/2" Phillips round head screws to secure the Dimmer to the junction box.
Make sure the arrow labeled “TOP” is pointing up.
Setup & Installation
(cont’d)
2
Install the Lightcloud Dimmer (cont’d)
2c
Use the two 6-32 5/16" Phillips flat-head screws provided to secure the faceplate bracket to the Dimmer.
2d
Snap the faceplate onto the faceplate bracket.
Setup & Installation
(cont’d)
3
Labeling your device
DEVICE IDs
ZONE NAME
PANEL/
CIRCUIT #
For setup and maintenance, we provide two
Lightcloud Device Tables with the Gateway: one that you can attach to your panel and one to hand off to a building manager. Attach the
Device Identification stickers included with each device to a row, then write in additional information, such as Zone name, Panel/Circuit Number, and whether or not a zone uses dimming.
4
Power up
To add your Lightcloud Dimmer to your system, enable Setup Mode via the Lightcloud application or call RAB at 1 (844) 544-4825. When the
Dimmer powers up, it will automatically try to join, and keep trying until it is able to join.
If you are installing multiple devices, you may wait until they are all installed to enable
Setup Mode.
When all devices have been commissioned, remember to disable Setup Mode.
ON
5
Confirm device connectivity
Confirm Network Status Indicator is solid green (see details below).
Functionality
Configuration
To pair the Dimmer with a zone, assign scenes or perform other configuration, use the Lightcloud web application or call RAB:
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
or 1 (844) 544-4825
Overview
NETWORK
INDICATOR
SIGNAL
STRENGTH
INDICATOR
TOP BUTTON
DEVICE
BUTTON
BOTTOM
BUTTON
DIM LEVEL
INDICATOR
NIGHT
LIGHT
DEVICE BUTTON
(press using paperclip)
:
• Single press: Indicate in Lightcloud application
• Hold for 10 seconds: Force device to leave current
Lightcloud network
DIM LEVEL INDICATOR:
• Displays current dim level (Zone mode)
NIGHTLIGHT:
• White: Lit when zone is off so you can find the
dimmer
SIGNAL STRENGTH INDICATOR:
• Indicates strength of the connection to next
Lightcloud Device
NETWORK INDICATOR:
• Solid green: Connected to a Lightcloud network
• Blinking red: Not connected to a Lightcloud network
The network and signal strength indicators are lit for
10 minutes following initial power on. To display the
indicators later on, simply press the device button once.
TOP AND BOTTOM BUTTONS:
Functionality depends on which mode is being used; see next page for details.
Functionality
(cont’d)
Features
The Lightcloud Dimmer can be used in Switch Mode,
Dimmer Mode or Scene Mode. To switch between these modes and access other configuration options, use the Lightcloud web application, or call RAB at
1-844-LIGHTCLOUD.
SWITCH MODE: In Switch Mode, the Dimmer is paired with a specific zone to provide switching.
Top and Bottom Buttons:
• Single Press: Switch zone on/off
DIMMER MODE: Dimmer Mode takes Switch Mode and adds dimming capabilities.
Top Button:
• Single press while zone is off: switch zone on.
• Single press while zone is on: dim up to max gradually,
stopping at current position if bottom button is pressed.
• Press and hold while zone is on: dim up gradually,
release to set dim level.
Bottom Button:
• Single press while zone is on: switch zone off.
• Press and hold while zone is on: dim down gradually,
release to set dim level.
SCENE MODE: In Scene Mode, the top and bottom buttons activate preselected scenes. This can be configured using the Lightcloud web application or by calling RAB.
FCC Information:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference
that may cause undesired operation.
Note: This device has been tested and found to comply with the limits for
Class B digital devices pursuant to Part 15 Subpart B, of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
To comply with FCC RF exposure limits for general population/ uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
CAUTION: Changes or modifications to this equipment not expressly approved by RAB Lighting, Inc. may void the user’s authority to operate this equipment. Custom manufactured in China.
Lightcloud is a commercial wireless lighting control system
& service. It’s powerful and flexible, yet easy to use and install. Learn more at
lightcloud.com
1 (844) LIGHTCLOUD
1 (844) 544-4825 [email protected]
© RAB Lighting, Inc
170 Ludlow Avenue Northvale, NJ 07647
Custom manufactured in China
Welcome
Daylight
LCDAYLIGHT
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
1 (844) 544-4825 [email protected]
FCC Information:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: This device has been tested and found to comply with the limits for Class B digital devices pursuant to Part 15 Subpart B, of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
To comply with FCC RF exposure limits for general population/uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
CAUTION: Changes or modifications to this equipment not expressly approved by RAB Lighting, Inc. may void the user’s authority to operate this equipment.
Hello
Lightcloud is a wireless lighting control service.
The Lightcloud Daylight is a remote, self-powered, open-loop light sensor that can switch and dim
Lightcloud Controllers and other Lightcloud devices.
Product Features
Wireless Sensing & Configuration
Ambient Light Sensor
Innovative Self-Powered Design
No Batteries
Patent Pending
Contents
Lightcloud Daylight Instruction Manual Mounting Screws
Straight & Angled
Mounting Brackets
Specifications
PART NUMBER
LCDAYLIGHT
OPERATING TEMPERATURE
-10ºC to 40ºC
OPERATING HUMIDITY
10% RH to 95% RH
OVERALL DIMENSIONS
5.25” x 3.16” x 1”
Power Supply for Setup USB Cable for Setup
USB POWER SPECIFICATIONS
Nominal Input Voltage 100-240VAC
Nominal Input Current 6mA
Nominal Power 0.2W
Frequency 47Hz-63Hz
Warranty is active as long as service plan is active.
Indoor Rated.
What You Need
Lightcloud Gateway
A Lightcloud installation requires at least one Lightcloud Gateway to manage your devices.
Lightcloud Controller
(Or similar Lightcloud actuation device)
The Daylight is designed to remotely control one or more Lightcloud devices that are capable of switching or dimming, such as the Lightcloud Controller or
Ceiling Sensor.
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
1 (844) 544-4825 [email protected]
Setup & Installation
1
Plug in the Daylight device (setup only)
To join your Daylight to a Lightcloud network, plug it in with the included
Micro USB power adapter. The white Power Indicator will come on and the Device Status Indicator will blink red every 10 seconds until it is joined to your network. For setup purposes, you can plug the device in anywhere that’s convenient, but please stay near the location where it will be permanently installed in order to ensure continued network connectivity.
Once setup has been completed, you can unplug the device and it will operate exclusively on solar power—no batteries necessary.
2
Contact RAB to add your Daylight
Call us at 1(844) LIGHTCLOUD or email [email protected]
and we'll get your Daylight device added to your Lightcloud network immediately. When USB power is removed, it is normal for this
LED to be unlit.
DEVICE STATUS INDICATOR
Setup & Installation
(cont’d)
3
Find a Suitable Location
3a
The Daylight needs sunlight to operate, and must be within range of another Lightcloud device. Direct sunlight is ideal, but indirect sunlight may be acceptable if there’s enough of it.
3b
A skylight is a great location for the Lightcloud Daylight. Be aware of where shadows will land throughout the day and position the device where it will receive the most direct sunlight.
SKYLIGHT
Example of ideal placements
NOTE: Remember, south-facing surfaces usually receive more direct sunlight than north-facing surfaces.
Setup & Installation
(cont’d)
3c
The Daylight includes an angled mounting bracket that can be used to maximize the amount of sunlight landing on the device’s face.
DIRECT
SUNLIGHT
Use angled bracket to get more direct sunlight
3d
In some cases, you may want to use an extension of some kind
(not included) to mount the device from the ceiling. Just be sure it ends up in direct sunlight as much as possible.
CEILING
DIRECT
SUNLIGHT
May need to use an extension to obtain direct sunlight
!
!
The Daylight must be within range of a Lightcloud device or
Gateway. See “Finding a Location”
The Daylight will not act as a “repeater” to extend the range of your Lightcloud network. If you need to extend your network range, use a Lightcloud Controller or other AC-powered device.
Setup & Installation
(cont’d)
4
Install
4a
Screw the straight or angled mounting bracket to the mounting surface.
4b
Snap the Daylight onto the mounting bracket.
5
Configure
Login at lightcloud.com and click on Devices to associate a zone at your site. The application will show the last measured light level so you can configure actions to take at different levels. Or, simply call or email us:
1 (844) LIGHTCLOUD
1 (844) 544-4825 [email protected]
Functionality
Overview
DEVICE
BUTTON
DEVICE STATUS
INDICATOR
USB POWER
INDICATOR
AMBIENT
LIGHT SENSOR
DEVICE STATUS INDICATOR:
• Unlit: When not powered by USB, indicates that the device is joined to a
Lightcloud network and is operating normally
• Solid green: When powered by USB, indicates that the device is joined to a
Lightcloud network
• Green blink: After pressing the Device Button, indicates that a light level
measurement has been transmitted
• Single red blink every 10 seconds: Not joined to a Lightcloud network
•
Green/Red alternating: Resetting to factory defaults
USB POWER INDICATOR:
• White: Powered by USB
DEVICE BUTTON:
•
Press: Indicate in Lightcloud application and measure light level
• Hold for 10 seconds while USB powered: Force device to leave current
Lightcloud network
• Hold for 10 seconds while connecting USB power: Reset to factory defaults
and leave current network
DAYLIGHT HARVESTING:
Daylight Harvesting is the use of daylight to offset the use of electric lighting to light a space. If there’s enough daylight in a space, the Lightcloud Daylight can make sure the lights are turned down or off, and turn them back on when the sun goes down.
The Lightcloud Daylight automatically takes light level measurements every 10 minutes. Pressing the Device Button will make an immediate measurement. Call or email RAB, or log in to lightcloud.com to configure actions to take at different light levels, such as turning off a zone when the light level exceeds 50 foot-candles.
Welcome
Controller
LCCONTROL20/D10
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
1 (844) 544-4825 [email protected]
Contents
Lightcloud Controller NPT Nut O-ring
Instruction Manual
Wire Nuts x 4 x 2
Specifications
PART NUMBER
LCCONTROL20/D10
INPUT
120-277VAC, 50/60Hz
<2W (Standby - 4W (Active)
MAXIMUM SWITCHED LOAD RATINGS
For Control of Magnetic, Electronic Ballast or LED
277VAC: 20A Magnetic/Resistive
240VAC: 5A Tungsten/Electronic, 20A FLA/
60 LRA, 2HP
120VAC: 15A Tungsten, 1HP
OPERATING TEMPERATURE
-40ºC to +40ºC
OVERALL DIMENSIONS
1.55" diameter, 5.75" length
1/2" NPT Mount, Male
16AWG pigtails
WIRELESS RANGE
Line-of-Sight: 1000 feet
Obstructions: 100 feet
Warranty is active as long as service plan is active
Class 2
IP66 Rated
Indoor and Outdoor Rated
Wet and Damp Location
Plenum Rated
What You Need
Lightcloud Gateway
A Lightcloud installation requires at least one Lightcloud Gateway to manage your devices.
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
or 1 (844) 544-4825 [email protected]
Wiring
Panel
WHITE/RED
RED
WHITE
BLACK
Load
WHITE
BLACK
GRAY
PURPLE
0-10V DIMMING
SWITCHED NEUTRAL
The “Switched Neutral” white with red stripe wire is the neutral line for the load being switched.
This enables power measurement.
See the Power Measurement section under “Functionality” for more information.
Setup & Installation
1
Turn off power
WARNING
OFF
OFF
1a
Find a Suitable Location
Use these guidelines when installing devices:
• If there is a clear line of sight between two Lightcloud
devices, they can be placed up to 1000 feet apart.
• If the two devices are separated by ordinary drywall
construction, try to keep them within 100 ft. of each other.
• Brick, concrete and steel construction may require
additional Lightcloud devices to go around the obstruction.
Add an additional Lightcloud
Device to extend network range around corners
DRY WALL
OR SIMIL AR
Lightcloud Gateway
<= 100 ft.
BRICK ,
CONCRETE OR
METAL WALL
Setup & Installation
(cont’d)
2
Install your Lightcloud Controller
2a
Install at a Junction Box (Indoor/Outdoor)
To Load
WHITE
WHITE/RED
WHITE
BLACK
Lightcloud
Controller
™
RED
PURPLE
GRAY
0-10V DIMMING
0-10V is a common method of low-voltage control of dimmable drivers and ballasts.
Purple: 0-10V positive | Gray: 0-10V common
NOTE: The National Electrical Code requires that low-voltage wiring used in the same enclosure as high-voltage wiring have an equal or better insulation rating. You may need to complete your low-voltage wiring in another enclosure or use a partition.
2b
At Lighting Panel or Trough
WHITE
BLACK
Space and code allowing, you may install Lightcloud devices directly in your breaker box or lighting panel. Alternatively, break out lighting circuits and install Lightcloud devices in a separate trough.
Setup & Installation
(cont’d)
3
Labeling your device
2
1
CONTROLLER DEVICE IDs
3
Your Site Name
1
DEVICE ID ZONE NAME
Front Desk
PANEL/
CIRCUIT #
2
DIMMING
For setup and maintenance, we provide two Lightcloud Device Tables with the Gateway: one that you can attach to your panel and one to hand off to a building manager. Attach the Device Identification stickers included with each device to a row, then write in additional information, such as Zone name, Panel/Circuit Number, and whether or not a zone uses dimming.
4
Power up
To add new devices to your Lightcloud network, call RAB at
1 (844) LIGHTCLOUD, or email us at [email protected].
5
Confirm Device Connectivity
Confirm Status Indicator is Solid Green (see details below)
DEVICE IDENTIFICATION BUTTON
• Illuminated when device is powered
• Press once to highlight this device in the
Lightcloud Application
• Press twice to toggle circuit on and off
• Press twice and hold to set dim level
• Press and hold for 10 seconds to remove this device from a Lightcloud network
• Blinks when device is indicated from the
Lightcloud Application
SIGNAL INDICATOR
Illuminates when the device receives a message and indicates the strength of the signal.
3 - Best signal
2 - Acceptable signal
1 - Unacceptable signal
Consult the “Finding a Location” section for more information
STATUS INDICATOR
Solid GREEN when connected to your
Lightcloud network. Blinking RED when not connected. The device will automatically continue trying to connect to a network in Setup Mode.
6
Commission your devices
Log on to www.lightcloud.com or call 1 (844) LIGHTCLOUD
Functionality
Configuration
All configuration of Lightcloud products may be performed using the
Lightcloud web or mobile application, or by calling RAB.
WE’RE HERE TO HELP:
1 (844) LIGHTCLOUD
or 1 (844) 544-4825 [email protected]
Operating Modes
CONTROLLER
Provides switching and dimming for a single zone
TRIGGER
Detect when an attached circuit is open or closed. For example, you could attach the Controller in Trigger mode to an existing occupancy sensor to allow your Lightcloud system to react to the sensor.
BLACK
WHITE
BLACK
WHITE
RED
Existing
Occupancy
Sensor
BLACK
WHITE
Load
WHITE/RED
Lightcloud
Controller
™
REPEATER:
Disables zone control and power measurement, and extends the range of your network.
POWER MEASUREMENT:
The Lightcloud Controller is capable of measuring the power usage of the attached circuit. In order to utilize this function, the neutral wire of the load must be connected to the white-red sense wire. If the Switched Neutral line cannot be used, it should be tied to the regular neutral wires (i.e. all neutral wires joined).
POWER LOSS DETECTION
: If mains power to the Controller is lost, the device will detect this and alert the Lightcloud application.
EMERGENCY DEFAULT:
If communication is lost, the Controller may optionally fall back to a specific state, such as turning the attached circuit on.
!
Any wires not in use must be capped off or otherwise insulated.
FCC Information:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference
that may cause undesired operation.
Note: This device has been tested and found to comply with the limits for
Class B digital devices pursuant to Part 15 Subpart B, of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
To comply with the FCC's RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
CAUTION: Changes or modifications to this equipment not expressly approved by RAB Lighting may void the user’s authority to operate this equipment.
Lightcloud is a commercial wireless lighting control system
& service. It’s powerful and flexible, yet easy to use and install. Learn more at
lightcloud.com
1 (844) LIGHTCLOUD
1 (844) 544-4825 [email protected]
Custom manufactured in China
© RAB Lighting, Inc
170 Ludlow Avenue Northvale, NJ 07647
Download