TABLE OF CONTENTS
1. Safety Instruction
2. Technical Specification
3. How To Set The Unit
4. How To Control The Unit
5. Troubleshooting
6. Fixture Cleaning
User Guide
Professional Entertainment Technology
1-
1. Safety Instruction
Warning
Ÿ To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
Please read carefully the instruction, which includes important information
WARNING
about the installation, usage and maintenance.
moisture.
Ÿ Do not open the unit within five minutes after switching off.
Ÿ The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
Ÿ Please keep this User Guide for future consultation. If you sell the unit to another user, be
sure that they also receive this instruction booklet.
damaged.
Caution
Ÿ Unpack and check carefully there is no transportation damage before using the unit.
There are no user serviceable parts inside the unit. Do not open the housing or attempt
Ÿ Before operating, ensure that the voltage and frequency of power supply match the power
any repairs yourself. In the unlikely event your unit may require service, please contact
requirements of the unit.
your nearest dealer.
Ÿ It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the
Ÿ The unit is for indoor use only. Use only in a dry location.
unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the
Ÿ The unit must be installed in a location with adequate ventilation, at least 50cm from
structure to which you are attaching the unit is secure and is able to support a weight of 20
adjacent surfaces. Be sure that no ventilation slots are blocked.
kg for each unit.
Ÿ Disconnect main power before replacement or servicing.
Ÿ Make sure there is no flammable materials close to the unit while operating as it is fire
hazard.
2. Technical Specification
• Voltage:AC 100V/120V/230V 50/60Hz
Ÿ Use safety cable when fixes this unit. Don’t handle the unit by taking its head only, but
always by taking its base.
• The unit is DMX 512 fixture. It features full DMX 512 control. It can be also linked together
in master/slave connection, as many as required and run by built-in program chase
Ÿ Maximum ambient temperature is TA: 40℃. Don’t operate it where the temperature is
higher than this.
sequences automatically or by sound activation through an internal microphone to create
an intelligent effect.
Ÿ Unit surface temperature may reach up to 85℃. Don’t touch the housing bare-hand during
its operation. Turn off the power and allow about 15 minutes for the unit to cool down
before replacing or serving.
• It can be operated by DMX 512 control or can be used as an individual unit without a
controller.
• Features different preprogrammed chase patterns.
Ÿ In the event of serious operating problem, stop using the unit immediately. Never try to
• Please use a cable when connecting units together.
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or
• Accurate focusable optics system and ultra smooth stepping motors, Fan cooled.
malfunction. Please contact the nearest authorized technical assistance center. Always
• Pan: 540 deg. Tilt: 220 deg.
use the same type spare parts.
• Dimension: 266 x 276 x 302 mm
Ÿ Do not touch any wire during operation as high voltage might be causing electric shock.
2-
• Weight: 9 kg
3-
3. How To Set The Unit
3.2 Main Function
To select any of the given functions, press the MENU button up to when the required one is
3.1 Control Panel
showing on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected,
press the ENTER button to setup or it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the
MENU button. The main functions are showing below:
Display
To show the various menus and the selected functions
LED
DMX
On
DMX input present
MASTER
On
Master Mode
SLAVE
On
Slave Mode
SOUND
Flashing
Sound activation
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
Button
Mains input
IEC socket and integrated fuse holder, connect to main power cable.
Only for remote control
By connect to the 1/4’’ microphone jack to control the unit for Stand by, Function and Mode
function.
DMX 512 Address Setting
Press the MENU button up to when the
Sensitivity
is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
To adjust the sound receiving sensitivity
Once the address has been selected, press the ENTER button to setup or automatically
DMX input/output
For DMX512 link, use 3-pin XLR plug cable to link the unit together.
4-
return to the main functions without any change after 8 seconds. To go back to the functions
without any change press the MENU button again.
5-
Channel Mode
Blackout Mode
Press the MENU button up to when the
is shown on the display. Pressing ENTER
Press the MENU button up to when the
is showing on the display. Pressing
button and the display will blink. Use DOWN and UP button to select the (8 Channel) or
ENTER button and the display will blink. Use DOWN and UP button to select the
(15 Channel) mode. Once the mode has been selected, press the ENTER button to setup or
(yes blackout) or
automatically return to the main functions without any change after 8 seconds. To go back to
ENTER button to setup or automatically return to the main functions without any change
the functions without any change press the MENU button again.
after 8 seconds. To go back to the functions without any change press the MENU button
(no blackout) mode. Once the mode has been selected, press the
again.
Show Mode
Press the MENU button up to when the
button and the display will blink. Use DOWN and UP button to select the
or
(show 2) or
Pan Inversion
is showing on the display. Pressing ENTER
(show 3) or
(show 1)
(show 4) mode. Once the mode has
Press the MENU button up to when the
is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the
(normal)
been selected, press the ENTER button to setup or automatically return to the main
or
functions without any change after 8 seconds. To go back to the functions without any
button to setup or automatically return to the main functions without any change after 8
change press the MENU button again.
seconds. To go back to the functions without any change press the MENU button again.
(pan inversion) mode. Once the mode has been selected, press the ENTER
Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°.
Tilt Inversion
Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°.
Show 3 mode - Fixture is placed on the speaker, The spot is always projecting
Press the MENU button up to when the
is showing on the display. Pressing
to the audience’s direction; i.e in front of the stage. Pan
ENTER button and the display will blink. Use DOWN and UP button to select the
movement angel (left to right to left): 160°.
(normal) or
angel:
Tilt movement
90° (60° above horizon; 30° below horizon.)
Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in
front of the stage. Pan movement angel (left to right to
left):160°.
(tilt inversion) mode. Once the mode has been selected, press the
ENTER button to setup or automatically return to the main functions without any change
after 8 seconds. To go back to the functions without any change press the MENU button
again.
Tilt movement angel: 90° (vertically, front 75°;
Led Display
back 15°)
Press the MENU button up to when the
Slave Mode
is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
Press the MENU button up to when the
is showing on the display. Pressing
(Led on) or
(Led off) mode. Once the mode has been selected, press the ENTER
ENTER button and the display will blink. Use DOWN and UP button to select the
button to setup or automatically return to the main functions without any change after 8
(normal) or
seconds. To go back to the functions without any change press the MENU button again.
(2 light show) mode. Once the mode has been selected, press the
ENTER button to setup or automatically return to the main functions without any change
Test
after 8 seconds. To go back to the functions without any change press the MENU button
again.
Press MENU button up to when the
is show on the display.
Pressing ENTER button and the unit will run Self test by built in program and can test by
6-
7-
program. Back to the functions press MENU button again.
4. How To Control The Unit
Master Mode
You can operate the unit in three ways:
Press the MENU button up to when the
is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
1. By master/slave built-in preprogram function
2. By easy controller
. Once the mode has been selected,
3. By iLead controller (Please refer to the user guide of iLead) or universal DMX controller
press the ENTER button to setup or automatically return to the main functions without any
No need to turn the unit off when you change the DMX address, as new DMX address
change after 8 seconds. To go back to the functions without any change press the MENU
setting will be effected at once. Every time you turn the unit on, it will show
button again.
display and move all the motors to their ‘home’ position and you may hear some noises for
on the
about 20 seconds. After that the unit will be ready to receive DMX signal or run the built in
Fixture Hours
programs.
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
button and the display will show the number of working hours of the unit. To go back to the
4.1 Master/Slave Built In Preprogrammed Function
functions press the MENU button again.
By linking the units in master/slave connection, the first unit will control the other units to
give an automatic, sound activated, synchronized light show. This function is good when
Software version
you want an instant show. You have to set the first unit in master mode
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
(show 1) or
(show 2) or
(show 3) or
and select
(show 4) mode. Its
button and the display will show the version of software of the unit. To go back to the
DMX input jack will have nothing plugged into it, and Its master LED will be constantly on
functions press the MENU button again.
and sound LED will flash to the music. The other units will have to set in slave mode
and select
Reset
(normal) or
(2 light show) mode, Their DMX cables plugged into
the DMX input jacks (daisy chain) and the slave led lights will constantly on.
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
2-light show
button and all channels of the unit will return to their standard position. To go back to the
In
functions without any change press the MENU button again.
2-light show. In order to create a great light show, you can set
(slave mode),
means the unit works normally and
means
on the second unit to
get contrast movement to each other, even if you have two units only.
3.3 Home Position Adjust
Press Enter button for at least 5 seconds into offset mode to adjust the home position, use
4.2 Easy Controller
DOWN and UP button up to when the function (Focus, Pan, Tilt, B-red, B-green, B-blue) is
The easy remote control is used only in master/slave mode. By connecting to the 1/4”
shown on the display. Pressing ENTER button and the display will blink. Use DOWN and
microphone jack of the first unit, you will find that the remote control on the first unit will
UP button to adjust the home position. Once the position has been selected, press the
control all the other units functions press the MENU button again.
ENTER button to setup or automatically return to the offset functions without any change
Stand By
Blackout the unit
press the MENU button again, To go back to the main functions without any change after 8
Function
1. Sync. Strobe
seconds.
Select Show 1-4
Select Gobo/Color
2. Two-light strobe
3. Sound Strobe
8-
9-
Mode
Sound (LED OFF)
Show (LED Strobe)
LED ON
4.4 DMX 512 Configuration
4.3 iLead Controller
♦ Consistent DMX configuration enable iMove to be linked together with iRock and iShow
and controlled at the same time.
♦ DMX address can be set remotely by iLead controller (Please refer to the user manual of
iLead controller). No need to calculate the DMX channels of each fixture in the chain.
♦ Automatic switching between DMX function and built-in stand alone programs.
An universal DMX controller to control the units, you have to set DMX address from 1 to 512
channel so that the units can receive DMX signal.
Press the MENU button up to when the
is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press and keep ENTER button pressed up to when
the display stops blinking or storing automatically 8 seconds later. To go back to the
functions without any change press the MENU button again. If you use please refer to the
following diagram to address your DMX512 channel for the first 4 units.
DMX address can be setting remotely by IL-0824 controller. No need to calculate the DMX
channels of each fixture in the chain.
10-
11-
4.5 DMX512 Connection
The DMX 512 is widely used in intelligent lighting control, with a maximum of 512 channels.
1.
If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin
adapter-cable.
2.
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it
in the DMX-output of the last unit.
3.
Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to
the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is
a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded
connectors can easily distort the signal and shut down the system.
4.
The DMX output and input connectors are pass-through to maintain the DMX circuit,
when power is disconnected to the unit.
5.
Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6.
The end of the DMX 512 system should be terminated to reduce signal errors.
7.
3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
12-
13-
5. Troubleshooting
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
F. If The pan belt is broken
1.
Turn off the main power.
2.
Unscrew all the screws and open the base-housing cove.
3.
Unplug all the connect wires that from the arm to PC board and ignitor.
4.
Unscrew the screws that fix the axis gear.
5.
Change a new belt by going through all connect wires that from the arm to base, and
through the bridge for correct position.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
6.
Set up the gear axis to the bridge and screwed it. Note: do not press the belt.
2. If the DMX LED is on and no response to the channel, check the address settings and
7.
Put the belt around the axis gear and motor gear.
8.
Plug all the connect wires that form the arm to PC board and ignitor.
9.
Adjust the pan home position.
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
10. Screw the base-housing cover.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling. Check the LED for the response of the
master/ slave mode signal.
2. Wrong DMX address in the unit. Set the proper address.
D. No response to the sound
1. Make sure the unit does not receive DMX signal.
2. Check microphone to see if it is good by tapping the microphone
E. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
14-
15-
6. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
Ÿ Clean with soft cloth using normal glass cleaning fluid.
Ÿ Always dry the parts carefully.
Ÿ Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the
following specification and bears CE mark in accordance with the
provision of the Electromagnetic Compatibility (EMC) Directive
89/336/EEC.
EN55014-2: 1997 A1: 2001, EN61000-4-2: 1995; EN61000-4-3:
2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6: 1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN60598-1: 2000+ALL: 2000+A12: 2002
Safety of household and similar electrical appliances
Part 1: General requirements
16-
17-
Innovation, Quality, Performance
18-
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement