Southwire 23090T MaintenancePRO™ Smart Clamp Meter Specifications

Southwire 23090T MaintenancePRO™ Smart Clamp Meter Specifications

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Southwire 23090T MaintenancePRO™ Smart Clamp Meter Specifications | Manualzz

®

23090T

MaintenancePRO™ SMART 1000A CLAMP METER

Southwire’s new MaintenancePRO™ 23090T adds Bluetooth ® connectivity to a rugged high end clamp meter.

Used with our MApp™ mobile app, the 23090T lets electricians safely get the measurements they need even in hostile environments.

BLUETOOTH ®

ENABLED

BUILT IN NON-CONTACT

VOLTAGE (NCV) DETECTOR

1000A AC/DC

MAXIMUM

WORKS WITH

SOUTHWIRE'S NEW

MOBILE APP

SA

CAT IV

600V

UL61010-1

F ET Y RATE

D

CAPTURES INRUSH

CURRENT

®

1-855-SWTOOLS

(855-798-6657)

Southwiretools.com

©2016 Southwire Company, LLC. All rights reserved. ® and TM Trademark of Southwire Company, LLC.

®

Features

Bluetooth ® interface for downloading, viewing, and sharing one Southwire mobile app

Inrush Function captures motor start-up current

Precision TrueRMS meter

Hi-Res 50,000 count backlit display

Rugged meter with CAT IV 600V / CAT III 1000V

View readings and set up recording sessions right from your mobile phone

Add photos and notes to create a detailed report

Pull-up menu to modify meter settings remotely

E-Mail critical equipment issues to maintenance

23090T

MaintenancePRO™ SMART 1000A CLAMP METER

Specifications

FUNCTION

AC CURRENT

(50/60Hz)

DC CURRENT

ACmV

AC VOLTAGE

(50 TO 400Hz)

RANGE

500.00A

1000.0A

500.00A

1000.0A

500.0mV

5.0000V

50.000V

500.00V

1000.0V

110 to 1000V AC

RESOLUTION

10mA

0.1A

10mA

0.1A

0.01mV

0.1mV

1mV

10mV

0.1V

ACCURACY

±(% OF READING + DIGITS)

CAT IV 600V/Cat lll 1000V

TrueRMS

1.5" (38mm)

Autoranging

30 min. (approximately)

50,000 count backlit LCD

41° to 104°F (5° to 40°C)

-4° to 140°F (-20° to 60°C)

One 9V Battery

± (2.5% + 5)

± (2.5% + 5)

± (1.0% + 30)

10.3 x 3.3 x 1.7 in. (262x 84 x 43mm)

0.69 lb (315g)

± (3.0% + 8)

NCV

(NON-CONTACT AC VOLTAGE)

DCmV

DC VOLTAGE

RESISTANCE

CONTINUITY

DIODE TEST

CAPACITANCE

FREQUENCY

DUTY CYCLE

TEMPERATURE

GENERAL SPECIFICATIONS

Safety Rating

AC Response

Clamp Size

Operation

Auto Power Off (APO)

Display

Operating Temperature

Storage Temperature

Batteries

Dimensions

Weight

500.0mV

5.0000V

50.000V

500.00V

1000.0V

500.00Ω

5.0000kΩ

50.000kΩ

500.00kΩ

0.01mV

0.1mV

1mV

10mV

0.1V

0.01Ω

0.1Ω

10Ω

10pF

0.1nF

1nF

10nF

1µF

0.001Hz

0.01Hz

0.1Hz

1Hz

10Hz

100Hz

1kHZ

0.1%

0.1°F

0.1°C

± (1.0% + 5)

± (1.5% + 3)

± (1.0% + 9)

± (1.0% + 5)

5.0000MΩ

50.000MΩ

100Ω

1kΩ

± (2.0% + 10)

± (3.0% + 10)

Audible beeper < 35Ω

Typical test current and open circuit voltage: 0.3mA/< 2V DC

± (3.5% + 40) 500.00nF

5000.0nF

50.000µF

500.00µF

± (5.0% + 10)

5.000mF

50.000Hz

500.00Hz

5.0000kHz

50.000kHz

500.00kHz

5.0000MHz

10.000MHz

5.0 to 95.0%

-148.0 to 1832.0°F

-100.0° to 1000.0°C

± (0.3% + 2)

± (1.0% + 2)

± (1.0% + 4.5°F)

± (1.0% + 2.5°C)

®

1-855-SWTOOLS

(855-798-6657)

Southwiretools.com

©2016 Southwire Company, LLC. All rights reserved. ® and TM Trademark of Southwire Company, LLC.

advertisement

Related manuals

Download PDF

advertisement