EASITAG SINGLE

Installation Guide

Issue: 002a

EasiTag Single Installation Guide

1 Legal and Copyright Notice

Entrotec regularly develop and enhance product lines, these changes will be included in the latest documentation. Whilst every effort has been made to ensure the accuracy of the information supplied herein, Entrotec cannot be held responsible for any errors or omissions. The materials contained in this document are protected and may be subject to intellectual property rights.

Copyright 2016 by Entrotec Limited. All rights reserved.

2 Installation Specification

It is the responsibility of the installer to follow Entrotec’s installation and cable specification as well as ALL relevant wiring regulations. Failure to comply with Entrotec’s installation and cable specification may result in erratic operation of equipment and could invalidate any warranty.

Installations must comply with the following standards:

BS 7671: Requirements for electrical installations. IET Wiring Regulations 17th Edition.

BS EN 50133-1: Alarm systems. Access control systems for use in security applications.

System requirements.

BS EN 50133-2-1: Alarm systems. Access control systems for use in security applications.

General requirements for components.

BS EN 50133-7: Alarm systems. Access control systems for use in security applications.

Application guidelines.

BS 7807: Code of practice for design, installation and servicing of integrated systems incorporating fire detection and alarm systems and/or other security systems for buildings other than dwellings.

IET Wiring Regulations 17th Edition: Regulation 528-01 (Proximity to electrical services) imposes requirements for segregation of door entry / access control circuits (Band I), 230VAC mains circuits

(Band II) and other higher voltage circuits.

IET Wiring Regulations 17th Edition: Regulations 542 to 543 impose requirements for earthing and bonding conductors. Ensure ALL metalwork is bonded to the building’s earth, this includes call panels, exit switches, cabinets and metal conduit. Ring terminals and earth points are provided on call panels and cabinets to terminate earth cables, ensure these connections are made.

3 Warranty and Support

Entrotec systems are renowned for their reliability and have a 2 year warranty on all Entrotec manufactured products as standard. This warranty does not cover water damage, vandalism, mains electrical faults, lightning strikes, damage caused by miswiring or cable faults.

Entrotec offer complimentary training courses and telephone support:

0844 858 6370 (8:30am to 5pm Mon-Thurs and 8:30am to 4pm Friday – call charges may vary).

© 2016 Entrotec Ltd Page 3

EasiTag Single Installation Guide

Contents

1 Legal and Copyright Notice ................................................................................................ 3

2 Installation Specification .................................................................................................... 3

3 Warranty and Support ....................................................................................................... 3

4 Introduction ...................................................................................................................... 5

5 Cable Specification ............................................................................................................ 5

5.1

Typical Configuration ...................................................................................................... 5

6 Overview ........................................................................................................................... 6

6.1

EasiTag Single Panel – Rear View .................................................................................... 6

6.2

Connections, Settings and Fuses .................................................................................... 6

6.3

EasiTag Single Panel – Front View ................................................................................... 7

7 Power Supply Connections ................................................................................................ 7

8 Lock Connections ............................................................................................................... 8

8.1

Fail Open Lock ................................................................................................................. 8

8.2

Fail Closed Lock ............................................................................................................... 8

8.3

Lock Suppression ............................................................................................................ 8

9 Exit Switch and Fire Switch Connections ............................................................................. 9

10 Lock Release Time ............................................................................................................. 9

11 Inner Door Interface to Elite System ................................................................................. 10

11.1

Overview ....................................................................................................................... 10

11.2

Interface Connections ................................................................................................... 10

© 2016 Entrotec Ltd Page 4

EasiTag Single Installation Guide

4 Introduction

This guide covers the installation of EasiTag Single hardware and related features. For programming / setup of keys and other features, please refer to the EasiTag Setup Guide.

5 Cable Specification

Failure to comply with Entrotec’s cable specification may result in erratic operation of equipment.

The specification in Figure 1 shows the minimum cable requirements, allow for extra cabling if

redundancy is a requirement.

Connection

A Between PSU and each EasiTag Single:

B Between EasiTag Single and locks:

C Between EasiTag Single and exit switch:

D Between EasiTag Single and fire switch:

Cable

2 x 1.5mm² multi-stranded flex or singles

(and earth).

2 x 1.5mm² multi-stranded flex or singles

(route through any exit or fire switch for fail safe operation).

Unshielded Twisted Pair (UTP) cable, 2 cores.

(See B).

UTP cable, 2 cores. (See B).

FIGURE 1

5.1 Typical Configuration

Locks

B

Fire

Switch

B

Exit

Switch

B

EasiTag

Single

C + D

FIGURE 2

A

PSU

230VAC

© 2016 Entrotec Ltd Page 5

EasiTag Single Installation Guide

6 Overview

The EasiTag Single is an easy to use standalone access control system. It can store up to 250 user keys. Programming is fast and simple; the keys are securely added or deleted at the panel.

6.1 EasiTag Single Panel – Rear View

LCD Display PCB

ASS11130

+

-

PL4

TP1

PL2

PR1

Speaker

Volume

Speaker

Tone

Volume

TP2

PR2

PR3

5vA

Speaker

Volume

1 Amp

Fuse

Mic.

Volume

ENT11130B

TP3

12v

PL1

TP4

0v

PL3

Microphone

+

-

FS1

5vD

PL5

PR4

LCD

Contrast

12v 0v S1 S2 SN SB DO CA OP

SW1

Relay PCB

ASS14141

Proximity Reader PCB

ASS13137

12v

PL1

TRG

+

TRG

LVD

0v

ENT14141A

FS1

PL2

2 Amp

Fuse

12v

0v

C

NC

NO

0v

PL1

FIGURE 3

6.2 Connections, Settings and Fuses

Part

ASS11130

ASS11130

ASS11130

ASS11130

ASS11130

ASS14141

ASS14141

ASS14141

ASS13137

Item

PL1

PL4

SW1

PR4

FS1

PL1

PL2

FS1

PL1

Function

LCD display connections, exit switch input.

Proximity reader connection.

Programming button.

LCD display contrast adjustment.

1 Amp fuse (time delay). Main fuse.

Relay inputs.

Relay outputs, lock connections.

2 Amp fuse (time delay). Lock fuse.

Proximity reader connection.

FIGURE 4

Door Open Sounder

GST/BUZZER/DP

© 2016 Entrotec Ltd Page 6

EasiTag Single

6.3 EasiTag Single Panel – Front View

LCD Display

Status LED

Proximity Reader

FIGURE 5

7 Power Supply Connections

PL1

PL3

Microphone

+

-

FS1

12v 0v S1 S2 SN SB DO CA OP

Installation Guide

To

PSU

2 x 1.5mm²

12V

0V

12v

PL1

TRG

+

TRG

LVD

0v

ENT14141A

FS1

PL2

2 Amp

Fuse

12v

0v

C

NC

NO

0v

PL1

FIGURE 6

© 2016 Entrotec Ltd Page 7

EasiTag Single

8 Lock Connections

Installation Guide

8.1 Fail Open Lock

Figure 7 shows connections for fail open locks (power to hold), e.g. magnetic locks.

Relay

PCB

Exit Switch

Normally Closed

(if fitted)

Fire Switch

Normally Closed

(if fitted)

Fail Open

Lock

ENT14141A

2 Amp

Fuse

PL2

12v

0v

C

NC

NO

0v

+

_

Door Open

Sounder

FIGURE 7

8.2 Fail Closed Lock

Figure 8 shows connections for fail closed locks (power to release), e.g. electric strike.

Relay

PCB

Fail Closed

Lock

ENT14141A

2 Amp

Fuse

PL2

12v

0v

C

NC

NO

0v

+

_

Door Open

Sounder

FIGURE 8

8.3 Lock Suppression

Entrotec recommend locks with built in suppression. If such a lock is not being used it is ESSENTIAL to fit suitable suppression, as close to the lock as possible. This prevents back EMF and spikes from damaging equipment. Failure to fit adequate suppression may invalidate any warranty.

Entrotec recommend fitting a 1N4007 diode as close to the lock as possible.

+

To Relay

Lock

_

PCB

FIGURE 9

© 2016 Entrotec Ltd Page 8

EasiTag Single

9 Exit Switch and Fire Switch Connections

Figure 10 shows connections for exit / fire switches.

LCD Display PCB

Installation Guide

12v 0v S1 S2 SN SB DO CA OP

Fire Switch

Normally Open

Exit Switch

Normally Open

FIGURE 10

For double pole push to exit / fire switches with fail open locks, see section 8.1.

10 Lock Release Time

The lock time is adjustable between 1-60 seconds, the factory default is 5 seconds. This can be adjusted using the programming button on the LCD display PCB and a red master key.

Press the programming button repeatedly to scroll through the menu options until ‘Lock time’ is

displayed (Figure 11), the current setting will be displayed.

FIGURE 11

Present the red master key to the reader to increment the lock time, repeat this step until the desired time is reached. To exit the programming menu, press the programming button or allow the system to automatically time out.

© 2016 Entrotec Ltd Page 9

EasiTag Single

11 Inner Door Interface to Elite System

Installation Guide

11.1 Overview

EasiTag Single can control an inner door on a system where the outer door is controlled by an Elite door entry system. This is a useful feature when a system has an inner door with no call panel, but is also opened by a resident called from the main door.

FIGURE 12

11.2 Interface Connections

Figure 13 shows connections for Elite door entry interface.

EasiTag Single LCD Display PCB

12v 0v S1 S2 SN SB DO CA OP

FIGURE 13

EasiTag Single

Inner door only opens with release from handset or key fob

Outer door opens with release from handset, key fob or

Trades button

Elite PCB

PL22

DR

VT

0V

BZ

S2

S1

DS

© 2016 Entrotec Ltd Page 10

Entrotec Ltd

5 Ashwood Court

Oakbank

Livingston EH53 0TL

Telephone: 01506 886 230

Support: 0844 858 6370 www.entrotec.com

Manufactured in the UK

advertisement

Key Features

  • Stores up to 250 keys
  • Simple programming
  • Standalone design
  • Inner door interface to Elite system
  • Adjustable lock release time
  • Fail open and fail closed lock support
  • Exit switch and fire switch connections
  • Door open sounder
  • Lock suppression

Frequently Answers and Questions

How many keys can the EasiTag Single store?
The EasiTag Single can store up to 250 user keys.
How do I program the EasiTag Single?
Programming is done directly at the panel. Refer to the EasiTag Setup Guide for detailed instructions.
What types of locks can be used with the EasiTag Single?
The EasiTag Single supports both fail open and fail closed locks. You can connect magnetic locks (fail open) or electric strikes (fail closed).
Can I connect an exit switch to the EasiTag Single?
Yes. The EasiTag Single includes connections for both exit switches and fire switches.
How can I control an inner door on an Elite system with the EasiTag Single?
Connect the EasiTag Single to the Elite system using the provided interface connections. The inner door will then open when a resident is called from the main door or by using a key fob.