Entrotec EasiTag Single Installation Guide
The EasiTag Single is a standalone access control system that can store up to 250 user keys. Programming is simple, adding and deleting keys is done directly at the panel. It can be used to control inner doors on a system where the outer door is controlled by an Entrotec Elite door entry system.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
EASITAG SINGLE
Installation Guide
Issue: 002a
EasiTag Single Installation Guide
1 Legal and Copyright Notice
Entrotec regularly develop and enhance product lines, these changes will be included in the latest documentation. Whilst every effort has been made to ensure the accuracy of the information supplied herein, Entrotec cannot be held responsible for any errors or omissions. The materials contained in this document are protected and may be subject to intellectual property rights.
Copyright 2016 by Entrotec Limited. All rights reserved.
2 Installation Specification
It is the responsibility of the installer to follow Entrotec’s installation and cable specification as well as ALL relevant wiring regulations. Failure to comply with Entrotec’s installation and cable specification may result in erratic operation of equipment and could invalidate any warranty.
Installations must comply with the following standards:
BS 7671: Requirements for electrical installations. IET Wiring Regulations 17th Edition.
BS EN 50133-1: Alarm systems. Access control systems for use in security applications.
System requirements.
BS EN 50133-2-1: Alarm systems. Access control systems for use in security applications.
General requirements for components.
BS EN 50133-7: Alarm systems. Access control systems for use in security applications.
Application guidelines.
BS 7807: Code of practice for design, installation and servicing of integrated systems incorporating fire detection and alarm systems and/or other security systems for buildings other than dwellings.
IET Wiring Regulations 17th Edition: Regulation 528-01 (Proximity to electrical services) imposes requirements for segregation of door entry / access control circuits (Band I), 230VAC mains circuits
(Band II) and other higher voltage circuits.
IET Wiring Regulations 17th Edition: Regulations 542 to 543 impose requirements for earthing and bonding conductors. Ensure ALL metalwork is bonded to the building’s earth, this includes call panels, exit switches, cabinets and metal conduit. Ring terminals and earth points are provided on call panels and cabinets to terminate earth cables, ensure these connections are made.
3 Warranty and Support
Entrotec systems are renowned for their reliability and have a 2 year warranty on all Entrotec manufactured products as standard. This warranty does not cover water damage, vandalism, mains electrical faults, lightning strikes, damage caused by miswiring or cable faults.
Entrotec offer complimentary training courses and telephone support:
0844 858 6370 (8:30am to 5pm Mon-Thurs and 8:30am to 4pm Friday – call charges may vary).
© 2016 Entrotec Ltd Page 3
EasiTag Single Installation Guide
Contents
© 2016 Entrotec Ltd Page 4
EasiTag Single Installation Guide
4 Introduction
This guide covers the installation of EasiTag Single hardware and related features. For programming / setup of keys and other features, please refer to the EasiTag Setup Guide.
5 Cable Specification
Failure to comply with Entrotec’s cable specification may result in erratic operation of equipment.
The specification in Figure 1 shows the minimum cable requirements, allow for extra cabling if
redundancy is a requirement.
Connection
A Between PSU and each EasiTag Single:
B Between EasiTag Single and locks:
C Between EasiTag Single and exit switch:
D Between EasiTag Single and fire switch:
Cable
2 x 1.5mm² multi-stranded flex or singles
(and earth).
2 x 1.5mm² multi-stranded flex or singles
(route through any exit or fire switch for fail safe operation).
Unshielded Twisted Pair (UTP) cable, 2 cores.
(See B).
UTP cable, 2 cores. (See B).
FIGURE 1
5.1 Typical Configuration
Locks
B
Fire
Switch
B
Exit
Switch
B
EasiTag
Single
C + D
FIGURE 2
A
PSU
230VAC
© 2016 Entrotec Ltd Page 5
EasiTag Single Installation Guide
6 Overview
The EasiTag Single is an easy to use standalone access control system. It can store up to 250 user keys. Programming is fast and simple; the keys are securely added or deleted at the panel.
6.1 EasiTag Single Panel – Rear View
LCD Display PCB
ASS11130
+
-
PL4
TP1
PL2
PR1
Speaker
Volume
Speaker
Tone
Volume
TP2
PR2
PR3
5vA
Speaker
Volume
1 Amp
Fuse
Mic.
Volume
ENT11130B
TP3
12v
PL1
TP4
0v
PL3
Microphone
+
-
FS1
5vD
PL5
PR4
LCD
Contrast
12v 0v S1 S2 SN SB DO CA OP
SW1
Relay PCB
ASS14141
Proximity Reader PCB
ASS13137
12v
PL1
TRG
+
TRG
LVD
0v
ENT14141A
FS1
PL2
2 Amp
Fuse
12v
0v
C
NC
NO
0v
PL1
FIGURE 3
6.2 Connections, Settings and Fuses
Part
ASS11130
ASS11130
ASS11130
ASS11130
ASS11130
ASS14141
ASS14141
ASS14141
ASS13137
Item
PL1
PL4
SW1
PR4
FS1
PL1
PL2
FS1
PL1
Function
LCD display connections, exit switch input.
Proximity reader connection.
Programming button.
LCD display contrast adjustment.
1 Amp fuse (time delay). Main fuse.
Relay inputs.
Relay outputs, lock connections.
2 Amp fuse (time delay). Lock fuse.
Proximity reader connection.
FIGURE 4
Door Open Sounder
GST/BUZZER/DP
© 2016 Entrotec Ltd Page 6
EasiTag Single
6.3 EasiTag Single Panel – Front View
LCD Display
Status LED
Proximity Reader
FIGURE 5
7 Power Supply Connections
PL1
PL3
Microphone
+
-
FS1
12v 0v S1 S2 SN SB DO CA OP
Installation Guide
To
PSU
2 x 1.5mm²
12V
0V
12v
PL1
TRG
+
TRG
LVD
0v
ENT14141A
FS1
PL2
2 Amp
Fuse
12v
0v
C
NC
NO
0v
PL1
FIGURE 6
© 2016 Entrotec Ltd Page 7
EasiTag Single
8 Lock Connections
Installation Guide
8.1 Fail Open Lock
Figure 7 shows connections for fail open locks (power to hold), e.g. magnetic locks.
Relay
PCB
Exit Switch
Normally Closed
(if fitted)
Fire Switch
Normally Closed
(if fitted)
Fail Open
Lock
ENT14141A
2 Amp
Fuse
PL2
12v
0v
C
NC
NO
0v
+
_
Door Open
Sounder
FIGURE 7
8.2 Fail Closed Lock
Figure 8 shows connections for fail closed locks (power to release), e.g. electric strike.
Relay
PCB
Fail Closed
Lock
ENT14141A
2 Amp
Fuse
PL2
12v
0v
C
NC
NO
0v
+
_
Door Open
Sounder
FIGURE 8
8.3 Lock Suppression
Entrotec recommend locks with built in suppression. If such a lock is not being used it is ESSENTIAL to fit suitable suppression, as close to the lock as possible. This prevents back EMF and spikes from damaging equipment. Failure to fit adequate suppression may invalidate any warranty.
Entrotec recommend fitting a 1N4007 diode as close to the lock as possible.
+
To Relay
Lock
_
PCB
FIGURE 9
© 2016 Entrotec Ltd Page 8
EasiTag Single
9 Exit Switch and Fire Switch Connections
Figure 10 shows connections for exit / fire switches.
LCD Display PCB
Installation Guide
12v 0v S1 S2 SN SB DO CA OP
Fire Switch
Normally Open
Exit Switch
Normally Open
FIGURE 10
For double pole push to exit / fire switches with fail open locks, see section 8.1.
10 Lock Release Time
The lock time is adjustable between 1-60 seconds, the factory default is 5 seconds. This can be adjusted using the programming button on the LCD display PCB and a red master key.
Press the programming button repeatedly to scroll through the menu options until ‘Lock time’ is
displayed (Figure 11), the current setting will be displayed.
FIGURE 11
Present the red master key to the reader to increment the lock time, repeat this step until the desired time is reached. To exit the programming menu, press the programming button or allow the system to automatically time out.
© 2016 Entrotec Ltd Page 9
EasiTag Single
11 Inner Door Interface to Elite System
Installation Guide
11.1 Overview
EasiTag Single can control an inner door on a system where the outer door is controlled by an Elite door entry system. This is a useful feature when a system has an inner door with no call panel, but is also opened by a resident called from the main door.
FIGURE 12
11.2 Interface Connections
Figure 13 shows connections for Elite door entry interface.
EasiTag Single LCD Display PCB
12v 0v S1 S2 SN SB DO CA OP
FIGURE 13
EasiTag Single
Inner door only opens with release from handset or key fob
Outer door opens with release from handset, key fob or
Trades button
Elite PCB
PL22
DR
VT
0V
BZ
S2
S1
DS
© 2016 Entrotec Ltd Page 10
Entrotec Ltd
5 Ashwood Court
Oakbank
Livingston EH53 0TL
Telephone: 01506 886 230
Support: 0844 858 6370 www.entrotec.com
Manufactured in the UK
advertisement
Key Features
- Stores up to 250 keys
- Simple programming
- Standalone design
- Inner door interface to Elite system
- Adjustable lock release time
- Fail open and fail closed lock support
- Exit switch and fire switch connections
- Door open sounder
- Lock suppression
Frequently Answers and Questions
How many keys can the EasiTag Single store?
How do I program the EasiTag Single?
What types of locks can be used with the EasiTag Single?
Can I connect an exit switch to the EasiTag Single?
How can I control an inner door on an Elite system with the EasiTag Single?
Related manuals
advertisement
Table of contents
- 3 Legal and Copyright Notice
- 3 Installation Specification
- 3 Warranty and Support
- 5 Introduction
- 5 Cable Specification
- 5 Typical Configuration
- 6 Overview
- 6 EasiTag Single Panel – Rear View
- 6 Connections, Settings and Fuses
- 7 EasiTag Single Panel – Front View
- 7 Power Supply Connections
- 8 Lock Connections
- 8 Fail Open Lock
- 8 Fail Closed Lock
- 8 Lock Suppression
- 9 Exit Switch and Fire Switch Connections
- 9 Lock Release Time
- 10 Inner Door Interface to Elite System
- 10 Overview
- 10 Interface Connections