KIRBY MORGAN SUPERLITE DEEP SEA DIVING HELMET MODEL
17A/B
SUPERVISORS EQUIPMENT CHECKS
PRIOR TO ENTRY INTO WATER
APPENDIX A2.4.1
01-25-17
NOTE:
This checklist is intended to be used with both KMDSI SuperLite 17A and B.
NOTE:
Helmet(s) being used in polluted waters, or extreme environments, will require
inspection that is more frequent.
CAUTION: KMDSI strongly recommends the use of a Tender to assist the diver when
“dressing-in”. The Tender should ensure the Helmet Liner is fastened to the Helmet
Shell and the Chinstrap is properly fastened under the divers chin, once the Helmet
is donned. After closing the Yoke/Neck Clamp Assembly, ensure that the safety pin
is installed.
WARNING: These are recommended minimum checks when using Kirby Morgan Helmets or
Masks. Additional checks may be required as dictated by the conditions and tasks
being performed. Failure to perform in-water checks may result in serious injury
or death.
CAUTION: All surface supplied diving with Kirby Morgan Helmets must include a fully
functional, properly maintained Emergency Gas System (“EGS”). The EGS should
be maintained in accordance with the applicable Modular Operations and
Maintenance Manual(s).
Date:
Helmet Serial #:
Associated Equipment Serial #(s):
Page 1
Technician (print name):
Kirby Morgan, SuperLite, Band Mask, KMB Band Mask, EXO, SuperMask, SuperFlow, and Rex are all registered trademarks of
Kirby Morgan Dive Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is not permitted without
written permission from KMDSI.
© Copyright 1970-2017 Kirby Morgan Dive Systems, Inc. All rights reserved. KMDSI manuals, checklists and technical and training
information is made available for the express use of owner/user of this Kirby Morgan products. No part of this material may be reproduced,
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc
Copyright 2003-2017, Dive Lab®., Inc. All rights reserved. TechTrnG 03101
STEP
PROCEDURES
1. Supply Gas
Supervisor:
a. Ensure gas to the diver.
2. Check Breathing
System
Diver- Check the following (a - e):
INITIALS
a. Open and close the Steady-Flow Valve to
ensure proper operation.
b. Check breathing resistance. Set Demand
Regulator Adjustment Knob for minimum
inhalation effort.
c. Press Purge Button to check gas purge
function.
d. Ensure Nose Block Device slides freely.
5. Check Dry Suit
Inflation Hose (if
applicable)
6. Check Entire Rig
Tender:
Soap and leak check Helmet/Mask gas fittings
and connections, including Emergency Gas
System.
7. Check Diver’s Entire Rig
Supervisor/Tender- Check
adjustment/fit of the entire rig,
including the following (a – f):
Kirby Morgan, SuperLite, Band Mask, KMB Band Mask, EXO, SuperMask, SuperFlow, and Rex are all registered trademarks of
Kirby Morgan Dive Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is not permitted without
written permission from KMDSI.
© Copyright 1970-2017 Kirby Morgan Dive Systems, Inc. All rights reserved. KMDSI manuals, checklists and technical and training
information is made available for the express use of owner/user of this Kirby Morgan products. No part of this material may be reproduced,
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc
Copyright 2003-2017, Dive Lab®., Inc. All rights reserved. TechTrnG 03101
Page 2
3. Check
Communications
4. Check Hot Water
Supply (if
applicable)
e. Ensure Emergency Valve opens and closes
properly. Then, ensure Emergency Valve is
closed and the Bail Out Cylinder Valve is
open.
Diver:
Perform communications check.
Tender:
Check hot water supply connections. Ensure
topside hot water supply has been switched to
diver and verify flow to hot water shroud and suit
(if used).
Tender:
Check dry suit Inflation Hose Connection.
Ensure dry suit Inflation Valve and Exhaust
Valve function properly.
NOTE: On the SL-17A/B, this a. On SuperLite 17 A/B, ensure the Rear
Hinge Tab is fully engaged on the
procedure will ensure the
alignment sleeve. Using thumb on the
Neck Clamp w/Yoke
bottom of Regulator Body, and
Assembly is properly
middle finger on Neck Clamp, attempt
adjusted prior to descent.
to “pop” Neck Clamp w/Yoke
Assembly from bottom rim of Helmet
NOTE: All equipment must be
.
adjusted properly and
functioning correctly.
The Helmet/Mask must
be breathing easily and
properly.
b. Diver’s Safety Harness.
c. Umbilical strain release.
d. EGS Hose Quick Disconnect.
e. Boots, gloves, knife, and other
accessories.
f. Helmet supply pressure, minimum
115 psig.
8. Check Breathing
Diver:
Check to ensure helmet is
breathing properly.
Note: All equipment must be
adjusted properly and functioning
correctly. The Helmet/Mask must
be breathing easily and properly.
Technician (Print)_______________________________________________________
Signature:___________________________________Date:______________________
Comments:_____________________________________________________________
KMDSI highly recommends that a certified KMDSI Repair Technician make all repairs and that
only genuine KMDSI repair and replacement parts be used. Owners of KMDSI products that elect
Kirby Morgan, SuperLite, Band Mask, KMB Band Mask, EXO, SuperMask, SuperFlow, and Rex are all registered trademarks of
Kirby Morgan Dive Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is not permitted without
written permission from KMDSI.
© Copyright 1970-2017 Kirby Morgan Dive Systems, Inc. All rights reserved. KMDSI manuals, checklists and technical and training
information is made available for the express use of owner/user of this Kirby Morgan products. No part of this material may be reproduced,
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc
Copyright 2003-2017, Dive Lab®., Inc. All rights reserved. TechTrnG 03101
Page 3
______________________________________________________________________
to do their own repairs and inspections should only do so if they possess the knowledge and
experience. All inspections, maintenance, and repairs should be completed using the appropriate
KMDSI Operations and Maintenance Manual(s). Persons performing repairs should retain all
replacement component receipts for additional proof of maintenance history. Should any questions
on procedures, components, or repairs arise, please contact Kirby Morgan Dive Systems, Inc., by
telephone at (805) 928-7772 or via e-mail at [email protected], or contact Dive Lab, Inc.,
by telephone at (850) 235-2715 or via e-mail at [email protected]
Page 4
NOTE: Use your Maintenance and repair log book P/N 125-001, to record all the maintenance
performed.
Kirby Morgan, SuperLite, Band Mask, KMB Band Mask, EXO, SuperMask, SuperFlow, and Rex are all registered trademarks of
Kirby Morgan Dive Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is not permitted without
written permission from KMDSI.
© Copyright 1970-2017 Kirby Morgan Dive Systems, Inc. All rights reserved. KMDSI manuals, checklists and technical and training
information is made available for the express use of owner/user of this Kirby Morgan products. No part of this material may be reproduced,
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc
Copyright 2003-2017, Dive Lab®., Inc. All rights reserved. TechTrnG 03101