Simscape™ Release Notes

Simscape™ Release Notes
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape™ Release Notes
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
How to Contact MathWorks
Latest news:
www.mathworks.com
Sales and services:
www.mathworks.com/sales_and_services
User community:
www.mathworks.com/matlabcentral
Technical support:
www.mathworks.com/support/contact_us
Phone:
508-647-7000
The MathWorks, Inc.
3 Apple Hill Drive
Natick, MA 01760-2098
Simscape™ Release Notes
© COPYRIGHT 2007–2017 by The MathWorks, Inc.
The software described in this document is furnished under a license agreement. The software may be used
or copied only under the terms of the license agreement. No part of this manual may be photocopied or
reproduced in any form without prior written consent from The MathWorks, Inc.
FEDERAL ACQUISITION: This provision applies to all acquisitions of the Program and Documentation
by, for, or through the federal government of the United States. By accepting delivery of the Program
or Documentation, the government hereby agrees that this software or documentation qualifies as
commercial computer software or commercial computer software documentation as such terms are used
or defined in FAR 12.212, DFARS Part 227.72, and DFARS 252.227-7014. Accordingly, the terms and
conditions of this Agreement and only those rights specified in this Agreement, shall pertain to and
govern the use, modification, reproduction, release, performance, display, and disclosure of the Program
and Documentation by the federal government (or other entity acquiring for or through the federal
government) and shall supersede any conflicting contractual terms or conditions. If this License fails
to meet the government's needs or is inconsistent in any respect with federal procurement law, the
government agrees to return the Program and Documentation, unused, to The MathWorks, Inc.
Trademarks
MATLAB and Simulink are registered trademarks of The MathWorks, Inc. See
www.mathworks.com/trademarks for a list of additional trademarks. Other product or brand
names may be trademarks or registered trademarks of their respective holders.
Patents
MathWorks products are protected by one or more U.S. patents. Please see
www.mathworks.com/patents for more information.
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Contents
R2017a
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mode Charts: Define distinct modes for component behavior .
Enumerations: Specify discrete set of acceptable parameter
values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Run-Time Parameter Support for Declaration Functions: Tune
values used in MATLAB functions that declare block
parameters without regenerating code . . . . . . . . . . . . . . .
Block-Level Diagnostics for Numbers of Equations
and Unknowns: Identify overdefined or underdefined
components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . . .
1-2
1-2
1-4
1-5
1-6
1-8
simscape.findNonlinearBlocks Function: Identify
components with nonlinear equations . . . . . . . . . . . . . . . .
1-8
On-Demand Update for Variable Viewer and Statistics Viewer:
Faster review of modeling statistics . . . . . . . . . . . . . . . . .
1-8
Gas Pressure and Flow Rate Sources that Perform no
Thermodynamic Work: Configure flow conditions without
affecting temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-9
Thermodynamic Properties Sensor Blocks: Measure
thermodynamic quantities in gas and thermal liquid
domains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-9
Laminar-Turbulent Regime Definition by Pressure Ratio:
Improve simulation robustness with smoother regime
transitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-9
Bulk Modulus Logging for Hydraulic Chamber Block: Record
bulk modulus during simulation . . . . . . . . . . . . . . . . . . .
1-10
Rotational Friction and Translational Friction Blocks: Improve
simulation speed and robustness . . . . . . . . . . . . . . . . . . .
1-11
Input Derivative Setting for Piecewise Constant Signals:
Smoother handling of discrete inputs to Simscape network
1-11
iii
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
tanh Function in PS Math Function Block: Calculate
hyperbolic tangent of a Simscape physical signal . . . . . . .
Improved Spectrum Analyzer: Analyze signals in the frequency
domain using additional units and harmonics . . . . . . . . .
Increased robustness for the ode23t solver . . . . . . . . . . . .
Functionality being removed or changed . . . . . . . . . . . . . . .
1-12
1-12
1-13
1-13
R2016b
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Conditional Sections: Define variants within component files
Declaration Functions: Call MATLAB from member
declarations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Implicit Reference Connection Syntax: Simplify connections to
reference node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4D Table Lookup: Define lookup tables with four independent
variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Additional MATLAB operators allowed in Simscape
language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Two-Phase Fluid Base Classes: Energy calculations updated for
simulation robustness . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . . .
Gas Domain and Block Library: Model gas systems with various
levels of idealization . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dry Node Detection: Check for dry nodes in hydraulic
systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PS Lookup Table (4D) Block: Graphically define implicit
equations that require lookup tables with four independent
variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Improved Simulation Logging Speed: Stream data to disk 5 to
30% faster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spectrum Analyzer Block: Display frequency spectrum of timedomain signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Memristor block that lets you model resistance as function of
current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hydraulic mass flow rate source and sensor blocks . . . . . . .
Variable Viewer configuration preferences . . . . . . . . . . . . .
iv
Contents
2-2
2-2
2-2
2-4
2-5
2-5
2-6
2-8
2-8
2-8
2-9
2-9
2-9
2-10
2-10
2-10
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Descriptive variable names in Simscape Results Explorer . .
Improved scalability of generated code . . . . . . . . . . . . . . . .
Highlighting available for Simscape connection lines . . . . . .
Property Inspector available for Simscape blocks . . . . . . . .
Two-Phase Fluid Blocks: Energy calculations updated for
simulation robustness . . . . . . . . . . . . . . . . . . . . . . . . . . .
Functionality being removed or changed . . . . . . . . . . . . . . .
2-11
2-11
2-11
2-12
2-12
2-13
R2016a
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lookup Table Improvements: Define 3D tables, interpolate
using Akima splines . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Event Variables and edge Operator: Capture values at
events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Integral Operator, integ: Specify time integration of an
expression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Improved attributes for member visibility and access . . . . . .
Simscape language improved ease of use . . . . . . . . . . . . . . .
Additional MATLAB operators allowed in Simscape
language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Improved strictness and accuracy . . . . . . . . . . . . . . . . . . . . .
Change to Thermal Liquid domain definition . . . . . . . . . . .
New base classes for Thermal Liquid components . . . . . . . .
Renamed Thermal Liquid component source files . . . . . . . .
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . .
Run-Time Parameters: Speed up simulation tasks and modify
component parameter values without regenerating C code
Simulation Speed Improvements: Up to 5x speed improvement
for simulations using generated code . . . . . . . . . . . . . . . .
Stream Logging Data to Disk: Increase capacity for Simscape
simulation results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Simscape Component Block: Efficiently create custom
components by selecting Simscape language file directly from
block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Simscape Results Explorer Unit Selection: Select y-axis units
directly in plot pane . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2
3-2
3-3
3-4
3-5
3-6
3-8
3-9
3-12
3-12
3-12
3-14
3-14
3-15
3-15
3-16
3-16
v
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
PS Lookup Table (3D) Block: Graphically define implicit
equations that require lookup tables with three independent
variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Validation of Signal Units: Ensure consistent units specification
on Simulink signals connected to Simscape physical
networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Resistor block in the Electrical Elements library . .
Mass Flow Rate & Thermal Flux Sensor (TL) block renamed
Thermal Liquid volumetric flow rate source and sensor
blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Custom environment pressure in Thermal Liquid converter
blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Numerical improvements in Thermal Liquid blocks for greater
model fidelity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sign reversal of thermal expansion coefficient . . . . . . . . . . .
Functionality being removed or changed . . . . . . . . . . . . . . .
3-17
3-18
3-20
3-20
3-20
3-21
3-21
3-22
3-23
R2015aSP1
Bug Fixes
R2015b
vi
Contents
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2
Units handling refinements in Simscape language . . . . . . . .
5-2
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . . .
5-3
Two-Phase Fluid domain and block library . . . . . . . . . . . . . .
Variable priority option None for initialization . . . . . . . . . . .
Periodic Operators library . . . . . . . . . . . . . . . . . . . . . . . . . . .
Speed and efficiency improvements for simulation of switched
linear systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Domain-specific line style propagation through block icons . .
Rotational Inerter and Translational Inerter blocks . . . . . . .
5-3
5-3
5-4
5-4
5-4
5-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Real-Time Performance Advisor checks for physical models . .
Real-Time Simulation Documentation Enhancements . . . . . .
Variable Viewer link to block diagram renamed . . . . . . . . . .
Naming schema change within the data logging variable
structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5
5-5
5-5
5-6
R2015a
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . . .
Variable Viewer link to block diagram . . . . . . . . . . . . . . . . .
Improved solver efficiency for model initialization . . . . . . . . .
Sparkline plots for logged data . . . . . . . . . . . . . . . . . . . . . . .
Data logging for models created using ssc_new . . . . . . . . . . .
Pressure setting and name change for Thermal Liquid reservoir
blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
New examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2
6-2
6-2
6-2
6-3
6-4
6-4
R2014b
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-2
Refrigeration example modeling two-phase fluid flow . . . . . .
7-2
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . . .
7-3
Domain-specific line styles for representing physical
connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Improved interface for connecting Simscape blocks . . . . . . . .
Option to configure logging of Simscape simulation results per
block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flat view option and improved diagnostics for Variable
Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Simscape Results Explorer . . . . . . . . . . . . . . . . . . . . . . . . . .
Simscape logging into Simulink single output . . . . . . . . . . . .
7-3
7-3
7-3
7-4
7-4
7-5
vii
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape logging integration with Simulation Data
Inspector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Infinite resistance and port terminator blocks . . . . . . . . . . . .
Performance improvements for linear systems in Normal and
Accelerator modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-6
7-6
7-7
R2014a
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ssc_build library build process that no longer requires C
compiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
priority attribute for setting relative priority of variable
target values during initialization . . . . . . . . . . . . . . . . . . .
Script for replacing through and across statements with
branches and equations . . . . . . . . . . . . . . . . . . . . . . . . . .
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . . .
Variables tab for specifying target value and priority for new
initialization process . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Variable Viewer for analyzing results of new initialization
process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Statistics Viewer that displays variable source and number of
eliminated variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fundamental Reluctance block . . . . . . . . . . . . . . . . . . . . . . .
Hydro-mechanical converter blocks with fluid compressibility
option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Handling of pressure or temperature below absolute zero
during simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input filtering options for 1-D/3-D connections . . . . . . . . . .
Software-in-the-loop simulation for physical models . . . . . .
Change in default settings for ssc_new . . . . . . . . . . . . . . . .
Functionality being removed or changed . . . . . . . . . . . . . . .
viii
Contents
8-2
8-2
8-2
8-3
8-5
8-5
8-8
8-8
8-9
8-9
8-9
8-10
8-10
8-10
8-10
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013b
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
branches section for defining the relationship between
component Through variables and nodes . . . . . . . . . . . . . .
import statement enabling simplified access to other
component classes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
connect statement support for vector and matrix physical
signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-2
9-2
9-4
9-4
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . . .
9-5
Thermal Liquid domain and block library . . . . . . . . . . . . . . .
Simscape model statistics viewer . . . . . . . . . . . . . . . . . . . . .
Removal of laminar-turbulent zero-crossings in hydraulic
blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
New examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Functionality being removed or changed . . . . . . . . . . . . . . . .
9-5
9-5
9-5
9-6
9-6
R2013a
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-2
Variable-size domain parameters . . . . . . . . . . . . . . . . . . . .
Vector and matrix physical signals . . . . . . . . . . . . . . . . . . .
10-2
10-2
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . .
10-3
Random Number and Uniform Random Number blocks . . . .
Perfect Insulator block for thermal domain . . . . . . . . . . . . .
Initialization and diagnostic improvements . . . . . . . . . . . . .
Model Advisor checks for outdated blocks and for physical unit
consistency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit definition of Hz now consistent with SI . . . . . . . . . . . .
New format for saving simulation data log objects . . . . . . . .
New examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Functionality being removed or changed . . . . . . . . . . . . . . .
10-3
10-3
10-3
10-4
10-5
10-6
10-6
10-7
ix
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2012b
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11-2
Connection of components within a Simscape file . . . . . . . .
floor, ceil, fix, and round functions . . . . . . . . . . . . . . .
11-2
11-3
Foundation Library and Simulation . . . . . . . . . . . . . . . . . . .
11-5
Speed and efficiency improvements for simulation of switched
linear systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Zero-crossing statistics for Simscape logging . . . . . . . . . . . .
Counter and Repeating Sequence blocks that facilitate discrete
sampling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Open-circuit terminator blocks for electrical, hydraulic, and
mechanical domains in Foundation library . . . . . . . . . . .
Viewable and customizable source files for additional
Foundation library blocks . . . . . . . . . . . . . . . . . . . . . . . .
New examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11-5
11-5
11-5
11-6
11-6
11-7
R2012a
x
Contents
Modeling Delays in Simscape Language . . . . . . . . . . . . . . . .
12-2
New Blocks for Modeling Delays . . . . . . . . . . . . . . . . . . . . . .
12-2
1D and 2D Interpolation Available in Simscape Language .
12-2
Input Filtering Usability Enhancements . . . . . . . . . . . . . . .
12-2
Zero Damping Allowed for Resistive Elements . . . . . . . . . .
12-4
Changes to Simscape Demos . . . . . . . . . . . . . . . . . . . . . . . . .
12-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2011b
Simscape Language Enables User-Defined Diagnostics
During Simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13-2
New Block for Modeling Discrete Delays . . . . . . . . . . . . . . .
13-3
Specialized Simulator for Linear Systems . . . . . . . . . . . . . .
13-3
Rebuilding of Custom Block Libraries Now Required . . . .
13-3
R2011a
Additional Hydraulic Sources . . . . . . . . . . . . . . . . . . . . . . . .
14-2
Improved Simulation Diagnostics . . . . . . . . . . . . . . . . . . . . .
14-2
Improved Scalability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14-2
Improved Algorithms for Algebraic Loop Detection and ZeroCrossing Robustness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14-3
Change in Evaluating Unit Expressions . . . . . . . . . . . . . . . .
14-3
R2010b
Simulation Data Logging Enhancements . . . . . . . . . . . . . . .
15-2
Zero-Crossing Handling Enhancements . . . . . . . . . . . . . . . .
15-2
New Implementation of Relational Functions Without Creating
Simulink Zero-Crossing Conditions . . . . . . . . . . . . . . . . .
15-2
Improved Zero-Crossing Detection Diagnostics . . . . . . . . . .
15-3
xi
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
C++ Code Generation Support . . . . . . . . . . . . . . . . . . . . . . . .
15-3
Sparse Solver Enhancement . . . . . . . . . . . . . . . . . . . . . . . . . .
15-3
Component Descriptor Is No Longer Inherited from the Base
Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15-3
Documentation Enhancements . . . . . . . . . . . . . . . . . . . . . . .
15-4
Changes to Simscape Demos . . . . . . . . . . . . . . . . . . . . . . . . .
15-4
R2010a
Magnetic Blocks Added to Foundation Library . . . . . . . . . .
16-2
Simulation Data Logging Now Available . . . . . . . . . . . . . . .
16-2
Simscape Diagnostics Improvements . . . . . . . . . . . . . . . . . .
16-2
Sparse Jacobian Support . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16-2
Ability to Generate Simscape Language Equations from
Symbolic Expressions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16-3
Placing Simscape Blocks in Nonvirtual Subsystems . . . . . .
16-3
Trimming and Linearization Documentation
Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16-3
Changes to Simscape Demos . . . . . . . . . . . . . . . . . . . . . . . . .
16-3
R2009b
Pneumatic Blocks Added to Foundation Library . . . . . . . .
xii
Contents
17-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
New and Enhanced Switches . . . . . . . . . . . . . . . . . . . . . . . . .
17-3
Intermediate Terms in Simscape Language Equations . . . .
17-3
Local Solver Support in Physical Networks . . . . . . . . . . . . .
17-3
Simulink Manifest Tool Support . . . . . . . . . . . . . . . . . . . . . .
17-4
SimState Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17-4
Model Reference Accelerator Mode Support . . . . . . . . . . . .
17-4
Physical Port Rotation for Simscape Blocks . . . . . . . . . . . .
17-4
R2009a
Simscape Language Source Protection . . . . . . . . . . . . . . . . .
18-2
Expanded MATLAB Support of Simscape Files . . . . . . . . . .
18-2
Viewable and Customizable Source Files for Foundation
Library Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18-2
Simscape Language Syntax Changes . . . . . . . . . . . . . . . . . .
18-3
Increased Efficiency of Simscape Language Equations
Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18-4
New Physical Signal Blocks to Facilitate Rounding . . . . . .
18-4
Model Reference Accelerator Mode Support . . . . . . . . . . . .
18-4
Changes to Simscape Demos . . . . . . . . . . . . . . . . . . . . . . . . .
18-4
xiii
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2008b
Simscape Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19-2
Explicit Solvers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19-2
New Ways to Model Variable Chambers . . . . . . . . . . . . . . . .
19-3
Model Reference Support . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19-3
More Solver Performance and Robustness Enhancements .
19-3
R2008a
Trimming Now Available for Simscape Models . . . . . . . . . .
20-2
Thermal Unit Conversions Now Supported . . . . . . . . . . . . .
20-2
Enhancement to Specifying Units . . . . . . . . . . . . . . . . . . . . .
20-2
New Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20-3
Enhancements to Simulation Algorithms . . . . . . . . . . . . . . .
20-3
“What’s This?” Context-Sensitive Help Available for Simulink
Configuration Parameters Dialog . . . . . . . . . . . . . . . . . . .
20-3
New Simscape Demo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20-4
R2007b
Code Generation Now Available for Simscape Models . . . .
xiv
Contents
21-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
New Thermal Block Libraries . . . . . . . . . . . . . . . . . . . . . . . .
21-2
Additional Physical Signal Blocks . . . . . . . . . . . . . . . . . . . . .
21-2
Improved Simulation Performance . . . . . . . . . . . . . . . . . . . .
21-2
New Simscape Demos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21-3
R2007a
Product Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22-2
Block Libraries Moved from SimHydraulics to Simscape . .
22-2
xv
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2017a
Version: 4.2
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2017a
Simscape Language
Mode Charts: Define distinct modes for component behavior
Mode charts provide an intuitive way to model components characterized by a discrete
set of distinct operating modes. A car clutch is a good example of such a component.
It has several operating modes, with each mode being defined by a different set of
equations. It also has a transition logic, with a set of predicate conditions defining when
the clutch transitions from one mode to another. It is possible to model this component
using primitive constructs, such as event variables and edge operators, but this way of
modeling lacks readability. For more complex components, the file becomes cumbersome
and unwieldy. Every time you model a component with multiple operating modes and
transitions, this component is a good candidate for a mode chart implementation.
These new constructs in Simscape™ language let you perform mode chart modeling:
• modecharts — A top-level section in a component file. It can contain one or more
modechart constructs.
• modechart — A named construct that contains a textual representation of the mode
chart: modes, transitions, and an optional initial state specification.
• modes — A section in a mode chart that describes all the operating modes. It can
contain one or more mode constructs.
• mode — A named construct that corresponds to a distinct operating mode of the
component, defined by a set of equations.
• transitions — A section in a mode chart that describes transitions between the
operating modes, based on predicate conditions.
• initial — An optional section in a mode chart that specifies the initial operating
mode, based on a predicate condition. If the predicate is not true, or if the initial
section is missing, then the first mode listed in the modes section is active at the start
of simulation.
The following component implements a simple chart with three operating modes. In the
first mode, the output signal equals 1. In the second mode, the output signal equals 2.
In the third mode, the output signal equals 3. The component transitions from the first
to the second mode when the input signal is negative, and from the second to the third
mode when the input signal is positive. The initial mode depends on the block parameter
value: if parameter p is negative, simulation starts with the block in the second mode,
otherwise — in the first mode.
1-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
component ExampleChart
inputs
u1 = 0;
end
outputs
y = 0;
end
parameters
p = 1;
end
modecharts
mc1 = modechart
modes
mode m1
equations
y==1;
end
end
mode m2
equations
y==2;
end
end
mode m3
equations
y==3;
end
end
end
transitions
m1->m2 : u1<0;
m2->m3 : u1>0;
end
initial
m2 : p<0;
end
end
end
end
1-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2017a
Enumerations: Specify discrete set of acceptable parameter values
Simscape language now supports MATLAB® enumerations in:
• Component parameters
• Event variables and when clause predicates
• Equation predicates
• Conditional declaration predicates
• Function arguments (such as an interpolation method in tablelookup)
• Mode charts
You define enumerations using a MATLAB enumeration class. For more information, see
“Enumerations” (MATLAB). The enumeration class must derive from the int32 type, for
example:
classdef offon < int32
enumeration
off (0)
on (1)
end
end
You can then use this enumeration in a component parameter:
parameters
fl_c = offon.off; % Fluid compressibility
end
In the resulting block dialog, the Fluid compressibility parameter will have a dropdown list of values, off and on, with off as the default.
You can also specify user-friendly strings to be displayed in the block dialog, instead of
member identifiers:
classdef damping < int32
enumeration
direct (0)
derived (1)
end
methods(Static)
function map = displayText()
1-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
map = containers.Map;
map('direct') = 'By damping value';
map('derived') = 'By no-load current';
end
end
end
Similar to MATLAB enumerations:
• When used in equations, enumeration members convert to integers according to the
specified value.
• You can define more than one identifier for the same integer value, for example:
classdef myColor < int32
enumeration
red (0)
blue (1)
yellow (2)
green (0)
end
end
The first identifier in the enumeration block with a given integer value is the actual
identifier, and subsequent identifiers are aliases.
Note: Although multiple identifiers with the same integer value are allowed, MathWorks
recommends using unique integer values within a Simscape language enumeration set,
for better clarity.
Run-Time Parameter Support for Declaration Functions: Tune values used
in MATLAB functions that declare block parameters without regenerating
code
Member declarations for parameters and variables can now include calls to MATLAB
functions that generate code. The ability to use declaration functions to compute derived
parameter values or initialize variables was introduced in R2016b (see “Declaration
Functions: Call MATLAB from member declarations” on page 2-2).
If a member declaration contains a declaration function, you can use a new member
attribute, MATLABEvaluation:
1-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2017a
• If you specify MATLABEvaluation = compiletime, the declaration function will be
evaluated only at compile time, and all the function input parameters will be marked
as compile-time only. Use this attribute if the MATLAB function does not support
code generation, to prevent the block user from accidentally designating any of the
function input parameters as Run-time in the block dialog.
• If you omit this attribute, or specify MATLABEvaluation = default, the
declaration function will be evaluated at run time if a run-time parameter appears in
its input parameters. Otherwise, it will be evaluated at compile time.
Block-Level Diagnostics for Numbers of Equations and Unknowns: Identify
overdefined or underdefined components
System diagnostics, run automatically at compile time, compare the number of equations
to the number of variables in the top-level model, as well as analyze the number of
equations, variables, and nodes for each block.
The diagnostics also check that the number of Through and Across variables in a custom
domain is the same. Although permitted by the language semantics, having a different
number of Through and Across variables significantly restricts component connections.
For a domain with an equal number of Through and Across variables, well-defined
components generally comply with the following equation:
− − · =0,
where:
• is the number of variables.
• is the number of equations.
• is the number of nodes.
• is the number of domain Through variables.
Error reporting includes:
• The name of the block or blocks that contribute to the problem with the top-level
model.
• The number of equations and variables for each Simscape file where the counts are
different. Separate listings for the number of equations that explicitly appear in the
file and the number of equations added automatically by branch statements.
1-6
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
• Suggestions about possibly missing a branch statement in a component, or a reference
node in a composite component.
1-7
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2017a
Foundation Library and Simulation
simscape.findNonlinearBlocks Function: Identify components
with nonlinear equations
The new simscape.findNonlinearBlocks function checks a model and reports which
blocks, if any, contain nonlinear equations that keep the Simscape networks in the model
from being linear or switched linear. The function takes the name of the model (in single
quotes) as an argument and returns a cell array of the block names. If all the networks in
the model are linear or switched linear, the cell array is empty.
On-Demand Update for Variable Viewer and Statistics Viewer: Faster
review of modeling statistics
In previous releases, every time you opened the Variable Viewer, it updated the diagram
and ran the simulation for 0 seconds to calculate the actual initial values. Opening
the Statistics Viewer also triggered the block diagram update. For complex models, a
diagram update can last several minutes, and unnecessary diagram updates could lead to
loss of productivity.
In this release, opening the tool does not trigger an automatic update. When you open
the Variable Viewer or Statistics Viewer, it gets populated with the data from the last
simulation or diagram update. You have to update the data explicitly by clicking the
Refresh button (
both.
). If both tools are open, clicking Refresh in one of them updates
The status at the bottom of each tool displays the timestamp of its last update. If you
have modified the model since the viewer has last been updated, the Refresh button
displays a warning symbol (yellow triangle), and the timestamp at the bottom of the
viewer window turns red to indicate that the data in the viewer might not reflect the
latest model changes.
If you open a model, and then open the Variable Viewer or Statistics Viewer before
simulating the model, then the viewer does not contain any data. The Refresh button
displays a warning symbol (yellow triangle), and a message at the top of the viewer
window tells you to click the Refresh button to populate the viewer with data.
1-8
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Gas Pressure and Flow Rate Sources that Perform no Thermodynamic
Work: Configure flow conditions without affecting temperature
All blocks in the Gas/Sources library now have a new Power added parameter that lets
you select whether the source performs work on the gas flow:
• Isentropic power — The source performs isentropic work on the gas to maintain
the specified pressure differential or mass flow rate, depending on the source type.
This is the default option, which is equivalent to the block behavior in the previous
release. Use this option to represent an idealized pump or compressor and properly
account for the energy input and output, especially in closed-loop systems.
• None — The source performs no work on the flow, neither adding nor removing power,
regardless of the pressure differential or mass flow rate produced by the source.
Use this option to set up the desired flow condition upstream of the system, without
affecting the temperature of the flow.
Thermodynamic Properties Sensor Blocks: Measure thermodynamic
quantities in gas and thermal liquid domains
Similar to the existing Thermodynamic Properties Sensor (2P) block in the Two-Phase
library, thermodynamic properties sensor blocks have been added to the Gas and
Thermal Liquid libraries:
• Thermodynamic Properties Sensor (G) — Represents an ideal sensor that measures
specific enthalpy, density, specific heat at constant pressure, and specific entropy in a
gas network.
• Thermodynamic Properties Sensor (TL) — Represents an ideal sensor that measures
specific internal energy, density, and specific heat at constant pressure in a thermal
liquid network.
See the block reference pages for details.
Laminar-Turbulent Regime Definition by Pressure Ratio: Improve
simulation robustness with smoother regime transitions
For improved simulation robustness, especially in the presence of dry nodes, several
hydraulic blocks now contain a new Laminar transition specification parameter, with
these options:
1-9
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2017a
• Reynolds number — The transition from laminar to turbulent regime is assumed
to take place when the Reynolds number reaches the value specified by the Critical
Reynolds number parameter. This is the way these blocks worked before, and all
the equations are the same as in the previous releases.
• Pressure ratio — The transition from laminar to turbulent regime is defined by
the following equations:
cr = (avg + atm)(1 – lam)
avg = (A + B)/2
where:
•
cr
is the minimum pressure for turbulent flow.
•
A
and B are gauge pressures at ports A and B, respectively.
•
atm
•
lam
is the atmospheric pressure, 101325 Pa.
is the value of the new block parameter, Laminar flow pressure ratio. The
default value of this parameter is 0.999.
The change affects the Constant Area Hydraulic Orifice and Variable Area Hydraulic
Orifice blocks in the Foundation library, as well as several Simscape Fluids™ isothermal
blocks.
New blocks use Pressure ratio as the default Laminar transition specification
option. However, when you open an existing model, the Laminar transition
specification parameter value is Reynolds number and the simulation results are the
same as in previous releases.
Bulk Modulus Logging for Hydraulic Chamber Block: Record bulk
modulus during simulation
Bulk modulus variable has been added to the logged simulation data for the Constant
Volume Hydraulic Chamber block. To log and plot data for fluid bulk modulus:
1-10
1
Enable simulation data logging.
2
Run the simulation.
3
Open the Simscape Results Explorer.
4
In the left pane, expand the node representing a Constant Volume Hydraulic
Chamber block and select the bulk_inst node. The right pane displays the plot of
the instantaneous bulk modulus during simulation.
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Rotational Friction and Translational Friction Blocks: Improve simulation
speed and robustness
Rotational Friction and Translational Friction blocks now have a new Breakaway
friction velocity parameter, which replaces the Transition approximation
coefficient and Linear region velocity threshold parameters. The block equations
are now smoother and introduce no zero crossings, which results in faster and more
robust simulation.
Compatibility Considerations
Simulation results for existing models using the Rotational Friction and Translational
Friction blocks can change slightly.
Input Derivative Setting for Piecewise Constant Signals: Smoother
handling of discrete inputs to Simscape network
Simscape solver may require that you provide time derivatives of some of the input
signals, especially if you use an explicit solver. You can control the way you provide
time derivatives for each input signal by configuring the Simulink-PS Converter block
connected to that input signal. One way of providing the necessary input derivatives is
by filtering the input through a low-pass filter. You can also provide first and second
derivatives separately, through additional ports on the Simulink-PS Converter block.
In previous releases, if you selected the Use input as is option and the solver
required derivatives:
• For continuous signals, the solver issued an error.
• For discrete signals (that is, for signals with sample time other than continuous),
the solver explicitly set the input derivatives to zero. This behavior could lead to
unexpected results for sampled continuous (piecewise constant) signals.
To make the solver behavior more transparent, the options in the Input Handling
section of the Simulink-PS Converter block dialog have changed. First, you make the
decision whether to filter input or provide the derivatives separately, by using the
Filtering and derivatives parameter:
• If you set this parameter to Filter input, derivatives calculated, the input
filtering functionality works the same as before. Select the first-order or second-order
1-11
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2017a
filter, by using the Input filtering order parameter, and set the appropriate Input
filtering time constant (in seconds) parameter value for your model.
• If you do not want to filter the input, keep the Filtering and derivatives parameter
as Provide signals. Then, select the Provided signals parameter value: Input
only, Input and first derivative, or Input and first two derivatives.
Additional Simulink® input ports appear on the Simulink-PS Converter block, as
needed, to let you connect the signals providing input derivatives.
• If your signal is piecewise constant, you can explicitly set the input derivatives to
zero by selecting the Zero derivatives (piecewise constant) value for the
Filtering and derivatives parameter.
Note: When you add a new Simulink-PS Converter block to your model, the default input
handling options are Provide signals and Input only. However, in legacy models,
the Simulink-PS Converter blocks that had the Use input as is option now have
the Filtering and derivatives parameter set to Zero derivatives (piecewise
constant), to avoid compatibility issues and preserve the old simulation results.
tanh Function in PS Math Function Block: Calculate hyperbolic tangent of
a Simscape physical signal
The hyperbolic tangent function tanh(u) is now one of the choices available in the PS
Math Function block. This function is useful for providing smooth transitions around
zero. See the block reference page for details.
Improved Spectrum Analyzer: Analyze signals in the frequency domain
using additional units and harmonics
Signal analysis with the Spectrum Analyzer block has been improved:
• Visualize your signal spectrum as the root-mean squares (RMS) using Type > RMS.
When you select RMS as your spectrum type, you can choose from two spectrum units
(previously called power units), Vrms and dBV.
• On the Distortion Measurement panel, measure up to 99 harmonics using the Num.
Harmonics option.
1-12
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Increased robustness for the ode23t solver
The ode23t solver now has three performance levels (0, 1, and 2), to help you find the
right balance between the simulation speed and robustness. The default level is 2, which
provides the maximum robustness but can slow down the simulation.
Compatibility Considerations
Existing models can exhibit slower simulation times because of the increased solver
robustness. To revert to the way the ode23t solver operated in previous releases, you
can set its performance level to 0 by using this command:
slfeature(‘RobustOde23t’,0)
Functionality being removed or changed
Feature Name
What Happens When Use This Instead
You Use the Keyword?
ssc_reserved
Does not run
Compatibility
Considerations
Introduction of the
None
new compiler in
R2016a made this
function obsolete.
You still cannot
use any of the
Simscape language
keywords as model
or member names.
This function used to
list additional words
that you also could
not use. It returned
an empty list in
R2016b and has now
been removed. If
you use a word that
is not allowed as a
model or member
name (such as a
Simscape language
1-13
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2017a
Feature Name
1-14
What Happens When Use This Instead
You Use the Keyword?
keyword), you get a
compile-time error.
Compatibility
Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016b
Version: 4.1
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016b
Simscape Language
Conditional Sections: Define variants within component files
A conditional section is a top-level section guarded by an if clause. Conditional sections
are parallel to other top-level sections of a component file, such as declaration or
equations sections.
A conditional section starts with an if keyword and ends with an end keyword. It can
have optional elseif and else branches. The body of each branch of a conditional
section can contain declaration blocks, equations, structure sections, and so on, but
cannot contain the setup function. Nested conditional sections are allowed.
The if and elseif branches start with a predicate expression. The predicates must
be parametric expressions, because the structure of a model must be fixed at compile
time and cannot change once the model is compiled. If a predicate is true, the branch
gets activated. When all predicates are false, the else branch (if present) gets activated.
Elements (such as declarations, equations, and so on) from active branches only are
included in the compiled model.
The following restrictions apply:
• Predicates may depend on parameters of the parent (enclosing) component. They may
not depend, directly or indirectly, on parameters of member (embedded) components
or on domain parameters.
• Accessibility of class members declared inside conditional sections is equivalent to
private class members. They are not accessible from outside the component class,
even if their branch is active.
• The scope of the class members declared inside a conditional section is the entire
component class. However, using a conditional member outside the conditional section
when the section is not active results in a compilation error.
For more information, see Defining Component Variants.
Declaration Functions: Call MATLAB from member declarations
You can now use declaration functions to compute derived parameter values or initialize
variables, instead of doing this inside the setup function.
2-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
Declaration function is a MATLAB function used inside a member declaration section
in a Simscape file. A declaration function can be any MATLAB function (even if it is
not supported in the Simscape language equations section), including user-defined
functions on the MATLAB path. For example:
component A
parameters
p1 = 1;
p2 = 0;
end
parameters(Access=private)
pDerived = gamma(p1) + p2;
end
variables(Access=private)
vDerived = {value = {my_fcn(p1,p2) + 1, 'm'}, priority = priority.high };
end
equations
...
end
end
Use the Access=private attribute for member declaration unless all the arguments of
the declaration function are constants.
Exercise caution when using persistent variables inside a declaration function, because
this may lead to inconsistent results for multiple simulation runs.
Declaration functions can return multiple values. They follow the general MATLAB
function conventions for multiple return values. For example, if my_fcn() is a
declaration function that returns three values:
[id1, ~, id3] = my_fcn();
[id1] = my_fcn();
% omit the second return value
% rules of single assignment apply, nonrequested return values ignored
The following restrictions apply:
• You can use multiple value assignments on the left-hand side only for parameters and
variables with the Access=private attribute.
• When omitting return values using the placeholder attribute (~), at least one value
must be assigned. Empty declarations produce an error in Simscape language.
2-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016b
Implicit Reference Connection Syntax: Simplify connections to reference
node
The * symbol, previously used only in branch statements to indicate connection to a
reference node, can now also serve the same purpose in connect statements.
Previously, to connect a node to an absolute reference (ground), you needed to write
the corresponding branch statements and the grounding equations, setting the Across
variables equal to zero.
To ground a node in a composite component, you had to add a hidden grounding
component (domain reference block) as a member and explicitly connect the node to this
grounding component.
Now, you can indicate connections to an implicit reference node within the structure
section:
connections
connect(A, *);
end
The * symbol is not domain-specific, and the same structure section can contain
connections to implicit reference in different domains:
component abc
nodes
M = foundation.hydraulic.hydraulic;
N = foundation.electrical.electrical;
end
connections
connect(M,*);
connect(N,*);
end
end
However, multiple ports connected to an implicit reference within the same connect
statement must all belong to the same domain:
connections
connect(a, b, *);
end
2-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
The order of ports does not matter. This behavior is consistent with general connection
rules for multiple conserving ports. For more information, see Connections to Implicit
Reference Node.
Compatibility Considerations
All the domain reference blocks in Foundation library (such as Electrical Reference,
Mechanical Rotational Reference, and so on) have been updated to use the implicit
reference syntax. Therefore, the Through variables for these blocks are no longer
visible in logged simulation data. If your legacy models rely on using these variables in
simulation data analysis, add a corresponding Through variable sensor to your model
(such as the Current Sensor before the Electrical Reference block).
4D Table Lookup: Define lookup tables with four independent variables
The tablelookup function has been extended to support four-dimensional table lookup.
That is, the function can now compute an output value by interpolating the input value
against a set of data points in a four-dimensional table.
Additional MATLAB operators allowed in Simscape language
The following MATLAB operators are now allowed in a Simscape file:
Name
Notes
repmat
reshape
Expanded empty dimension is not
supported.
dot
Resulting unit is the product of the units of
the first two arguments.
cross
Resulting unit is the product of the units of
the first two arguments.
diff
Resulting unit is the same as the unit of
the first argument. In the two argument
overload, the upper bound on the second
argument is 4, due to a Simscape
limitation.
2-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016b
All arguments that specify size or dimension must be unitless constants or unitless
compile-time parameters.
Two-Phase Fluid Base Classes: Energy calculations updated for simulation
robustness
The base classes of the two-phase fluid domain have been updated to allow for smoother
and more robust energy flow transitions during fluid flow reversals. This update affects
which variables are declared, how they are computed, and whether they are logged
during simulation:
• one_port_horizontal.ssc and one_port_vertical.ssc — The port-node
specific internal energy (u_A), normalized specific internal energy (unorm_A), and
specific volume (v_A) are no longer declared or logged. Derived components dependent
on the eliminated variables must now explicitly declare those variables and provide
their equations.
• two_port_dynamic.ssc — The port-node specific internal energies (u_A, u_B),
normalized specific internal energies (unorm_A, unorm_B), and specific volumes (v_A,
v_B) are now computed from adiabatic expressions relating the port and internal
nodes. The updated properties no longer always match those carried by incoming
flows and, to prevent confusion in interpreting simulation results, are no longer
logged.
• two_port_steady.ssc — All variables are declared and logged as before. However,
derived components must include an additional equation relating the fluid properties
at port A to those at port B. For components that neither add nor subtract energy
from the flow, this equation reduces to an equality statement between the specific
total enthalpies,
ht_A == ht_B
where ht_A is the specific total enthalpy at port A and ht_B is that at port B. See the
+elements/local_restriction.ssc file for an example of such a component. See
the +sources/source_base.ssc file for an example of a component that adds or
subtracts energy, in this case, via isentropic processes.
Compatibility Considerations
The updates to the Two-Phase Fluid base classes affect all custom components derived
from them. To ensure that your custom components continue to work as expected,
you must modify the component files as described for the different base classes. As a
2-6
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
temporary workaround, you can point your custom components to the legacy base classes.
These classes are still defined but now have the string legacy_ prepended to their
names:
• legacy_two_port_dynamic.ssc
• legacy_two_port_steady.ssc
• legacy_one_port_horizontal.ssc
• legacy_one_port_vertical.ssc
To access the port-node specific internal energies or specific volumes in custom
components derived from the two_port_dynamic.ssc base class, you must now use
the appropriate sensor blocks. Use the Pressure & Internal Energy Sensor (2P) block
to measure the specific internal energy. Use the Thermodynamic Properties Sensor
(2P) block to measure the specific volume. You can also use simulation data logging and
Simscape Results Explorer to access the fluid properties at internal nodes.
2-7
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016b
Foundation Library and Simulation
Gas Domain and Block Library: Model gas systems with various levels of
idealization
The Foundation library now contains a gas domain and the Gas block library. This
library contains chambers, reservoirs, local restrictions, energy converters, sources and
sensors. It also contains the Gas Properties (G) block, which controls gas properties for
the attached circuit and lets you select the level of idealization: perfect gas, semiperfect
gas, or real gas.
Use these blocks for applications such as pneumatic actuation of mechanical systems,
natural gas transport through pipe networks, modeling gas turbines for power
generation, air cooling of thermal components, and so on.
For more information, see Modeling Gas Systems and the block reference pages. See also
Gas Domain for information on the gas domain definition.
Compatibility Considerations
The Gas block library replaces the Pneumatic library as the recommended way of
modeling pneumatic systems. The former Pneumatic library is now included in the
product installation as an example custom library. The pneumatic domain definition
is still provided with the software, and all the pneumatic blocks in your legacy models
continue to work as before. However, these blocks no longer receive full production
support and can be removed in a future release.
MathWorks recommends that, going forward, you use the Gas library for modeling
pneumatic systems. Unlike the Pneumatic library blocks, the blocks in the Gas library
do not have the requirement of adding fluid volumes to every node. Also, the blocks in
the Gas library provide enhanced simulation robustness during flow reversal. For more
information, see Flow Reversal.
Dry Node Detection: Check for dry nodes in hydraulic systems
A new Model Advisor check, Check for dry hydraulic nodes, lets you detect hydraulic
nodes that are considered dry due to a lack of compliance. The check is not triggered by
default when you run Model Advisor on your model. You can run this check by selecting
it under By Product | Simscape or By Task | Modeling Physical Systems.
2-8
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
After you run the check, a table of results appears in the right pane of the Model Advisor
window. The first column lists the dry nodes found, with the middle column listing the
blocks connected to each dry node. Each cell in the middle column of the table contains a
link to the block in question, and the corresponding cell in the third column contains the
name of port that connects to the dry node.
Clicking a link highlights the corresponding block in the model.
Consider adding one Constant Volume Hydraulic Chamber block to each dry node
in the list. The presence of dry hydraulic nodes can reduce the solver robustness
in complex Simscape models. By adding a hydraulic chamber to a node, you can
considerably improve the convergence and computational efficiency of a model. Adding
a chamber adds a degree of freedom. By adding a chamber, you replace a complex
algebraic constraint (the dry node) with a dynamic constraint. For more information, see
Troubleshooting Hydraulic Models.
For more information on using Model Advisor, see Consulting Model Advisor.
PS Lookup Table (4D) Block: Graphically define implicit equations that
require lookup tables with four independent variables
The new PS Lookup Table (4D) block computes an approximation to some function
f=f(x1,x2,x3,x4) given the x1, x2, x3, x4, f data points. The four inputs and the
output are physical signals. See the block reference page for details.
Improved Simulation Logging Speed: Stream data to disk 5 to 30% faster
In this release, there are significant speed improvements for streaming logged data
to disk. To stream data to disk, open the MATLAB Preferences dialog box, go to the
Simscape pane, and select the Stream data to temporary disk directory check box.
For more information, see Stream Logging Data to Disk.
Spectrum Analyzer Block: Display frequency spectrum of time-domain
signals
The Spectrum Analyzer block is now available in the Simscape > Utilities library. This
block contains a subset of functionality of the DSP System Toolbox™ block with the same
name.
2-9
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016b
The Spectrum Analyzer block accepts input signals with discrete sample times and
displays frequency spectra of these signals. It allows you to perform measurements and
analyze the signals using a variety of methods. For more information, see the Spectrum
Analyzer block reference page.
If you have both a Simscape license and a DSP System Toolbox license, then the
Spectrum Analyzer block in the Simscape > Utilities library is identical to the block in
the DSP System Toolbox > Sinks library. For more information, see Spectrum Analyzer
in the DSP System Toolbox documentation.
Memristor block that lets you model resistance as function of current
The new Memristor block in the Electrical Elements library models an ideal memristor
with nonlinear dopant drift approach. The behavior of memristor is similar to a resistor,
except that its resistance (also called memristance) is a function of the current that has
passed through the device. The memristance is defined by two states, A and B, with some
fraction of the device in one of those states at a given time.
Hydraulic mass flow rate source and sensor blocks
Two new blocks in the Hydraulic > Hydraulic Sources library let you specify mass flow
rate through the source (as opposed to volumetric flow rate, like the existing Hydraulic
Flow Rate Source and Hydraulic Constant Flow Rate Source blocks):
• Hydraulic Constant Mass Flow Rate Source — Maintains a specified constant mass
flow rate regardless of the pressure differential across the source. You specify the
mass flow rate through the source by using a block parameter.
• Hydraulic Mass Flow Rate Source — Maintains a specified mass flow rate regardless
of the pressure differential across the source. The mass flow rate through the source is
directly proportional to the signal at the control port M.
The Hydraulic Flow Rate Sensor block has an additional output port M that lets you
measure mass flow rate.
Variable Viewer configuration preferences
The new Save Viewer Configuration button in the Variable Viewer toolbar lets you
save the following configuration preferences:
2-10
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
• Variable Viewer view type (tree or flat)
• Visible columns
• Ordering of columns
• Filters applied for all columns (both visible and hidden)
• Sorting on a specific column
If you save viewer configuration, then the next time you open Variable Viewer, for this or
another model, it will open with the same configuration. This behavior is consistent with
saving other MATLAB preferences.
Descriptive variable names in Simscape Results Explorer
Simscape Results Explorer now makes it easy to establish connection between the logged
data and the corresponding block variable. When you select a variable (for example, w)
in the Simscape Results Explorer tree, the status panel at the bottom of the window
displays the descriptive name (for example, Rotor angle), which is consistent with the
name displayed on the Variables tab of the block dialog. Clicking on this descriptive
name of a variable opens the corresponding block dialog box.
If the descriptive name of a variable is too long to fit into the status panel, it is truncated
with an ellipsis (…). If you hover over the truncated name, the tooltip for the status panel
displays the entire descriptive name. Similarly, if you hover over a parameter name
in the block dialog box, the tooltip displays the parameter description and id. These
enhancements improve the product usability.
Improved scalability of generated code
Code generated from Simscape models now has better modularity and scalability.
Therefore, it is more compiler-friendly, especially for Visual Studio® C compiler.
Highlighting available for Simscape connection lines
You can now highlight physical signal and conserving connections in Simscape block
diagrams. Highlighting crosses subsystem boundaries, allowing you to trace a connection
across multiple subsystem levels. To highlight connections, right-click a connection line
and, from the context menu, select Highlight Connections.
2-11
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016b
To remove all highlighting, select Remove Highlighting from the model's context
menu, or select Display > Remove Highlighting.
This functionality is similar to highlighting Simulink signals to source and destination.
For more information, see Display Signal Sources and Destinations in the Simulink
documentation.
Property Inspector available for Simscape blocks
Property Inspector view is now available for Foundation library blocks and other blocks
authored using Simscape language (including blocks in Simscape add-on products). For
more information on Property Inspector, see Property Inspector: Edit parameters and
properties of model elements using a single interface in the Simulink Release Notes.
Two-Phase Fluid Blocks: Energy calculations updated for simulation
robustness
The smoothed upwind scheme used in the energy flow calculations now allows for
smoother transitions during reversals in flow direction. The smoother transitions are
in part due to an updated smoothing factor that improves numerical robustness when
energy variations are large and flow reversals frequent.
The Characteristic longitudinal length block parameter, used in the previous energy
flow rate calculations, is now obsolete. This parameter has been removed from all TwoPhase Fluid blocks. The affected blocks include Local Restriction (2P) and Variable Local
Restriction (2P) from the Elements library and all blocks from the Sources library.
The port-node fluid properties of the Pipe (2P) block are now computed from adiabatic
expressions relating the port nodes to the internal nodes. These properties no longer
always match those carried by incoming flows and, to prevent confusion in interpreting
simulation results, are no longer logged. The affected fluid properties include:
• Specific internal energy at port A (u_A in the simulation data log) and port B (u_B)
• Normalized specific internal energy at port A (unorm_A) and port B (unorm_B)
• Specific volume at port A (v_A) and port B (v_B)
These fluid properties are also no longer logged for one-port blocks that make no use
of them, including Reservoir (2P), Constant-Volume Chamber (2P), Translational
Mechanical Converter (2P), and Rotational Mechanical Converter (2P).
2-12
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Compatibility Considerations
To access the port-node specific internal energies or specific volumes, you must use the
appropriate sensor blocks. Use the Pressure & Internal Energy Sensor (2P) block to
measure the specific internal energy. Use the Thermodynamic Properties Sensor (2P)
block to measure the specific volume. You can still use simulation data logging and
Simscape Results Explorer to access the fluid properties at internal nodes.
Functionality being removed or changed
Feature Name
What Happens When Use This Instead
You Use the Keyword?
Compatibility
Considerations
Pneumatic domain
and block library
Still runs
See Compatibility
Considerations
under “Gas Domain
and Block Library:
Model gas systems
with various levels of
idealization” on page
2-8.
Gas domain and
block library
2-13
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
Version: 4.0
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
Simscape Language
Lookup Table Improvements: Define 3D tables, interpolate using Akima
splines
The tablelookup function has been extended to support three-dimensional table
lookup. That is, the function can now compute an output value by interpolating the input
value against a set of data points in a three-dimensional table.
The interpolation and extrapolation options have been improved:
• There are two interpolation options, linear and smooth. The smooth option replaces
the previously available cubic and spline options. It uses a modified Akima
algorithm, as described in Smooth Interpolation Algorithm, to produce a continuous
curve or surface with continuous first-order derivatives. It also tries to preserve the
slope and avoid undulations where the data suggests a flat region. The default is
linear, which provides the best performance.
• There are two extrapolation options, linear and nearest. The names of the options
are the same as in previous releases, but the underlying algorithms have changed.
The linear method now ensures a smooth connection between the interpolation
region and the extrapolation region. The nearest method produces a curve or surface
with continuous value at the boundary between the interpolation region and the
extrapolation region that does not go above the highest point in the data or below the
lowest point in the data.
Compatibility Considerations
The smooth interpolation option replaces the cubic and spline options, available in
previous releases. If your existing models use cubic or spline interpolation, these
options will be automatically mapped to smooth. The new method is superior in the
way it preserves the shape of the data and produces a continuous curve or surface with
continuous first-order derivatives. However, this enhancement can produce a change in
results for your legacy models.
The new interpolation algorithm tries to preserve the slope and avoid undulations where
the data suggests a flat region. It interprets the data as a flat region whenever there are
three or more consecutive colinear points in the table data. It then connects those three
or more points with a straight line. The colinear points do not have to be horizontal. To
3-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
ensure that the region between two data points is flat, insert an additional data point
between those two points.
The linear extrapolation method now ensures a smooth connection between the
interpolation region and the extrapolation region. The nearest method extends as a
constant that is now equal to the last interpolated value, rather than the last point in
the output table data. These enhancements can also produce a change in results for your
legacy models.
Event Variables and edge Operator: Capture values at events
Event is a conceptual notation that denotes a change of state in a system. Event
modeling lets you perform discrete changes on continuous variables. The two most
common applications of event modeling are:
• Trigger-and-hold mechanism, such as a triggered delay. For example, a component
has two inputs: u and x (triggered signal), and one output y. When and only when the
triggered signal x changes value from false to true, output y is reset to the value of u
at current time. y remains unchanged all other times.
• Enabled component, acting on a principle similar to Simulink enabled subsystem.
That is, the component has a control signal as input. If the control signal has a
positive value, then the component holds certain states to the most recent value,
or resets them. When the control signal is negative, the states change according to
component equations.
The following new constructs in Simscape language let you perform event modeling:
event variables, edge operator, when clause, and events section.
Event variables are piecewise constant, that is, they change values only at event
instants, and keep their values constant between events. You can declare internal
component variables of type integer or real as event variables by setting the Event=true
attribute.
The edge operator takes a scalar boolean expression as input. It returns true, and
triggers an event, when and only when the input argument changes value from false to
true. The return type of edge is event type. Event type is a special category of boolean
type, which returns true only instantaneously, and returns false otherwise.
The when clause serves to update the values of the event variables. The syntax is
when EventPredicate
3-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
var1 = expr1;
var2 = expr2;
...
end
EventPredicate is an expression that defines when an event occurs. It must be an
expression of event type. The variables in the body of the when clause must be declared
as event variables. When the event predicate returns true, all the variables in the body of
the when clause simultaneously get updated to the new values. The when clause can have
optional elsewhen branches. However, an else branch is not allowed.
The new events section in a component file manages the event updates. The events
section can contain only when clauses. The order of when clauses does not matter.
The following example implements a triggered delay component:
component Triggered
inputs
u = 0; % input signal
triggered = 0; % control signal
end
variables(Event=true)
x = 0;
end
outputs
y = 0;
end
equations
y == x;
end
events
when edge(triggered>0)
x = u;
end
end
end
For more information, see Discrete Event Modeling.
Integral Operator, integ: Specify time integration of an expression
The new integ operator lets you perform time integration of an expression in the
equations section of a Simscape file without declaring and initializing extra variables.
3-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
The full syntax is:
integ(expr, t_L)
where:
• expr is a Simscape language expression.
• t_L is the lower integration limit, specified as a delay time relative to current time.
This operand is optional.
The upper integration limit is the current simulation time. If you omit the lower limit,
the integration starts from simulation start time.
Improved attributes for member visibility and access
The new attribute ExternalAccess controls visibility of members in the user interface,
that is, outside Simscape language. In other words, this attribute controls whether
parameters, variables, and other members are visible and modifiable in block dialog
boxes, simulation logs, variable viewer, and so on. The attribute is applicable to all
member classes and has the following values:
• modify — The member is modifiable in the block dialogs and visible in the logs and
viewer.
• observe — The member is visible in the logs and viewer, but not modifiable.
• none — The member is visible nowhere outside the language.
The default value of the ExternalAccess attribute for a member depends on the value
of the Access attribute for that member.
Access
Default ExternalAccess
public
modify
protected
observe
private
observe
Members in the base class with Access=private are forced to have
ExternalAccess=none, to avoid potential collision of names between the base class and
the derived class.
3-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
When Access is explicitly set to private or protected, it does not make sense to
explicitly set ExternalAccess=modify . In this situation, the compiler issues a
warning and remaps ExternalAccess to observe.
Compatibility Considerations
The ExternalAccess attribute replaces the member attribute Hidden (which you could
previously set for all member classes, such as parameters, variables, and so on, including
member components of a composite component). The model attribute Hidden (which you
can set for components to control whether they show up in a generated library or report)
is not affected.
You do not currently need to update the existing component files. Members with a
Hidden attribute compile without warnings. In a future release, implicit specification
of the Hidden attribute on a member will start to produce warnings when you attempt
to build the component. Eventually, the Hidden attribute for members will be removed.
When writing new component files, use the new syntax.
If you want to update your existing component files, replace Hidden=true with
ExternalAccess=observe.
Simscape language improved ease of use
In an effort to lift restrictions, simplify the syntax, and extend the language capabilities,
the following enhancements have been implemented in this release:
• Arbitrary order of sections in a Simscape file. There may still be no more than one
setup section per component. Otherwise, a component file can now contain multiple
instances of declaration blocks or implementation sections of the same type, such as
branches, equations, and so on. The sections can appear in any order.
• der operator now supports higher order derivatives. For example, der(der(x)) is
the second order time derivative of x.
• All parameters are now variable-sized. In previous releases, only parameters passed
directly to tablelookup function could have variable size. Now, you no longer need
to specify the Size=variable attribute for table data parameters. You can also do
arithmetic on table data parameters:
component MyLookup
parameters
ud = [ 0 1 2 ];
3-6
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
yd = [ 0 1 2 ];
end
inputs
u = 0;
end
outputs
y = 0;
end
equations
y == tablelookup( ud, yd+1, u );
end
end
• Parameters may now be N-dimensional. This functionality is primarily intended for
the three-dimensional lookup tables, introduced in this release (see “Lookup Table
Improvements: Define 3D tables, interpolate using Akima splines” on page 3-2).
• Derived private parameters and variables. You can derive a parameter value by
specifying an expression containing other parameters. For example:
component HasDerivedParameter
parameters
Par1 = 0;
Par2 = 0;
end
parameters(Access=private)
DerivedParameter = Par1 + Par2;
end
equations
% Use DerivedParameter here.
end
end
If Par1 or Par2 is modified in the setup section, then DerivedParameter will
be the new sum of the two (and that change is applied at the moment of the setup
assignment). The deriving relationship is broken only if the derived parameter is
modified in the setup section.
The derived parameter must be declared with the Access=private attribute. The
expression used to derive the parameter cannot be time-dependent, that is, it cannot
contain operators such as time, der, delay, or integ. You can use the same method
to initialize a variable.
• Nested parameter and variable access in composite components. For example, if
component C contains component B, which in turn contains component A, both C and
3-7
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
B can assign values to parameters and variables of component A. In case of conflicting
assignment, the “outermost” one (in this example, component C) takes precedence.
• Use of member component parameters and variables in the composite component
equations. Similar to the previous example, you can now use parameters and
variables of component A in the equations of components B and C. For example:
component B
parameters
p1 = 0;
end
components
a = A(v1 = 10); % Sets initial condition of a.v1, as in previous releases.
end
equations
der(a.v1) == p1; % Uses variable from component A here. This is new
end
end
• Simple setup function. In general, you cannot specify a block parameter as run-time
if the underlying component uses it in the setup function. However, if the setup is
restricted to simple operations like error-checking, you can declare it as:
function setup %#simple
...
end
In this case, many of the parameters used in the setup function can be selected as
run-time parameters. For more information, see Simple Setup.
Additional MATLAB operators allowed in Simscape language
The following MATLAB operators are now allowed in a Simscape file:
3-8
Name
Discontinuous
ones
zeros
cat
horzcat
vertcat
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
Name
Discontinuous
sum
prod
mod
Yes
any
Yes
all
Yes
min
Yes
max
Yes
ndims
length
size
numel
isempty
isequal
Possibly, if arguments are real and have
the same size and commensurate units
isinf
Yes
isfinite
Yes
isnan
Yes
double
int32
Yes
uint32
Yes
Some of these operators were previously allowed only in the declaration section. They are
now allowed in all the other sections as well.
All arguments that specify size or dimension must be unitless constants or unitless
compile-time parameters.
Improved strictness and accuracy
As a continuation of improvements made in R2015b (see “Units handling refinements in
Simscape language ” on page 5-2), several more semantic changes have been made
to increase robustness and consistency of simulation results:
3-9
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
• Fully typed parameter modification. In the old compiler, parameters could be
updated with a value that either had commensurate unit or was unitless. In case of
unitless value, the parameter preserved the original unit. In the new compiler, like in
MATLAB, you can update a parameter with a value that has different size and unit.
As a result, updating to a unitless value no longer preserves the original unit, which
introduces a compatibility issue.
• Assertions on let variables. The old compiler effectively inlined let variable
declarations into the code, and then added implicit assertions to the appropriate
branches. The new compiler computes the values of let variables once per call, which
greatly improves performance. As a result, if your let statement contains functions
such as sqrt(u), log(u), and so on, the implicit assertion u>=0 is added up front.
Therefore, if the in part contains an if statement, with u<0 in one of the branches, it
triggers the assertion even if the let variable is used in another branch.
• Assertion for a^b where a < 0 && ~isinteger(b). For minor time steps, the
compiler still evaluates power as:
if a < 0
return -( (-a) ^ b );
else
return a^b;
end
However, it now issues a warning assertion if the above rule is violated for an
accepted time step.
Compatibility Considerations
When you rebuild your custom libraries for use with R2016a, you can get compilation
errors or simulation-time assertions if your Simscape files violate the new, stricter,
language rules.
For example, consider the following component:
component MyComp
components
r1 = resistor;
r2 = resistor(R=2);
end
function setup
r1.R = 1;
end
3-10
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
end
Updating a parameter to a unitless value no longer preserves the original unit, and
therefore you will now get a compilation error about units being not commensurate. To
avoid the error, specify fully typed values when modifying parameters. For example:
component MyComp
components
r1 = resistor;
r2 = resistor(R={2, 'Ohm'});
end
function setup
r1.R = {1, 'Ohm'};
end
end
Another example concerns the assertions on let variables. Consider the following code:
let
v = sqrt(u);
in
if u < 0
y == 0;
else
y == v;
end
end
Even though variable v is used only in the else branch, the implicit assertion is added
at the beginning:
assert(u >= 0);
let
v = sqrt(u);
in
if u < 0
y == 0;
else
y == v;
end
end
Any negative value of u, instead of successfully executing through the if branch, will
now trigger the assertion. To avoid the error, rewrite the file as follows:
3-11
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
if u < 0
y == 0;
else
y == sqrt(u);
end
Change to Thermal Liquid domain definition
The energy flow rate replaces the thermal flux as a Through variable in the Foundation
Thermal Liquid domain.
The new Through variable is part of a broader change to the energy equations used
in Thermal Liquid components. The updated equations are now more readable and
extensible, enabling you to more easily check and add energy terms. The equations
omit kinetic energy terms in a common approximation that has negligible impact on
simulation results.
Compatibility Considerations
If you created custom components for the Thermal Liquid domain, you might need to
update your code to reflect the new domain definition.
New base classes for Thermal Liquid components
Components in the Thermal Liquid domain inherit from new base classes. Simscape
software continues to support the old base classes but these components no longer
depend on them. This change affects the converter, pipe, restriction, reservoir, and source
components.
Compatibility Considerations
The new base classes omit certain variables defined in the old base classes. If you
created custom components that inherit from these component classes and call any of the
missing variables, you might need to update your code. This issue does not affect custom
components that inherit directly from the old base classes.
Renamed Thermal Liquid component source files
Component files for Pipe (TL), Translational Mechanical Converter (TL), and Rotational
Mechanical Converter (TL) blocks have been renamed. Use the new file names to open
3-12
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
the files and view the source code for the blocks. The table shows the old and new files
names.
New File Name
Old File Name
pipe_resistive
resistive_tube
pipe_resistive_compressibility
resistive_tube_with_dynamic_compressibility
pipe_resistive_compressibility_inertia
pipeline_segment
translational_converter
translational_converter_steady_compressibility
translational_converter_compressibility
translational_converter_dynamic_compressibility
rotational_converter
rotational_converter_steady_compressibility
rotational_converter_compressibility
rotational_converter_dynamic_compressibility
3-13
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
Foundation Library and Simulation
Run-Time Parameters: Speed up simulation tasks and modify component
parameter values without regenerating C code
You can now modify certain block parameters between simulation runs without
regenerating C code or triggering the diagram update.
Unlike Simulink blocks, where all parameters are tunable at run time unless otherwise
specified, the default for Simscape block parameters is that they are modifiable at
compile time. To make a parameter modifiable at run time, you have to designate it as
such.
Tunable parameters (that is, parameters that you can modify during a simulation
run) are not supported for Simscape blocks. If a Simscape parameter is designated
as run-time, it means that you can modify its value between simulation runs without
recompiling the model.
To specify run-time parameters:
1
Set the preference to show the run-time parameters drop-down in block dialogs.
On the MATLAB Toolstrip, click Preferences. In the left pane of the Preferences
dialog box, select Simscape, and then in the right pane, select the Show run-time
parameter settings check box. Click OK.
2
Open a block dialog box in your model. Because of the preference setting, there is
now an extra drop-down box next to each parameter. By default, all these drop-down
boxes display Compile-time.
3
For the parameter that you want to modify, switch the drop-down value to Runtime. If the parameter currently has a numeric value, create a MATLAB variable
and replace the parameter value with this variable.
4
In the tool bar at the top of the model window, click Enable Fast Restart.
5
You can now run the simulation repeatedly and change the variable value between
simulations without recompiling the model.
For more information, see Run-Time Parameters.
3-14
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Simulation Speed Improvements: Up to 5x speed improvement for
simulations using generated code
In this release, there are significant speed improvements both for desktop simulations
and for those using generated code. For example, a benchmark medium-sized electrical
network, with approximately 200 nodes, shows the following results:
Simulation type
R2015b Time
R2016a Time
Speed Improvement
Desktop simulation
10.4 s
8.0 s
1.3 times
Simulink Coder™
Rapid Simulation
Target (RSim)
12.2 s
6.1 s
2.0 times
Simulink Coder
(GRT) with local
solver
15.2 s
3.1 s
4.9 times
Stream Logging Data to Disk: Increase capacity for Simscape simulation
results
In previous releases, logged simulation data was saved in a workspace variable of type
simscape.logging.Node, named as specified by the Workspace variable name
configuration parameter. Saving data to the workspace can slow down the simulation
and consume memory. Data logging options, such as Decimation or Limit data points,
helped alleviate the issue by limiting the number of saved data points. You could also try
logging data for a subset of blocks, or using time intervals.
The new method of streaming logged data to disk significantly increases the data logging
capacity, because you are no longer limited by the system memory. You can now log
simulation data for all blocks in a large model, or for selected blocks for a very long
simulation time.
To stream data to disk, open the MATLAB Preferences dialog box, go to the Simscape
pane, and select the Stream data to temporary disk directory check box. When this
preference is turned on, the simulation data, in the form of a simlog object generated
during simulation, is stored in an HDF5 file in a temporary directory. The workspace
variable of type simscape.logging.Node, named as specified by the Workspace
variable name configuration parameter, still gets created, but instead of storing all the
simulation data it references the simlog object in the temporary file. The temporary file
persists as long as there is a logging variable name in the workspace that references it.
3-15
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
You view and analyze logged simulation data exactly as before, with all the interaction
between the workspace variable and the stored object happening behind the scenes.
There are two new functions that handle saving logged data to a file (other than the
temporary file) and loading it from a file into the workspace:
• simscape.logging.export(simlog, 'fileName') stores the simulation data in a
specified HDF5 file. simlog is the simulation log variable name. fileName is the
name and path to destination file.
• var = simscape.logging.import('fileName') creates a workspace variable of
type simscape.logging.Node, which references the simlog object in the specified
HDF5 file. var is the variable name. If you do not assign a variable name when
calling the function, then the workspace variable name is ans.
By default, the Stream data to temporary disk directory preference is turned off,
and data logging works the same as in previous releases.
For more information, see Stream Logging Data to Disk.
Simscape Component Block: Efficiently create custom components by
selecting Simscape language file directly from block
In previous releases, generating Simscape blocks from textual component files required
building the custom block libraries. You can still use the ssc_build command to
generate a custom block library from a complete package of Simscape component files.
However, the new Simscape Component block in the Utilities library lets you generate a
Simscape block directly from a textual component file, skipping the library build process.
For more information, see Selecting Component File Directly from Block.
Simscape Results Explorer Unit Selection: Select y-axis units directly in
plot pane
When you display logged simulation data in Simscape Results Explorer, the data along
the x-axis is always time, in seconds. However, you can now change the y-axis units
directly on the plot.
Each of the plots now has a drop-down arrow next to the unit name for the y-axis. When
you click this arrow, a context menu appears containing names of all the units in the unit
registry that are commensurate with the current plot unit, as well as two other options:
3-16
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
• Default — Use the default unit.
• Specify — Type the unit name or expression in a pop-up window and click OK. The
specified unit name or expression must be commensurate with the current plot unit.
Once you select the option you want, the drop-down menu collapses and the plot is
redrawn in specified units.
For more information, see Plot Simulation Data in Different Units.
Compatibility Considerations
Under Plot options, you can switch the Plot signals option from Separate to
Overlay, to overlay multiple plots on the same axes. In previous releases, you could
overlay plots with commensurate y-axis units. Now, if you want to overlay several plots,
select the same y-axis unit for all these plots.
PS Lookup Table (3D) Block: Graphically define implicit equations that
require lookup tables with three independent variables
The new PS Lookup Table (3D) block computes an approximation to some function
f=f(x1,x2,x3) given the x1, x2, x3, f data points. The three inputs and the output are
physical signals. See the block reference page for details.
Compatibility Considerations
With the addition of three-dimensional table lookup, the axis naming schema has moved
from (x,y,z) to (x1,x2,x3). Parameter names in the PS Table Lookup (1D) and
PS Table Lookup (2D) blocks have been changed, to make them consistent with the
PS Lookup Table (3D) block. The parameter names in the block source have also been
changed, to make them consistent with the new naming schema.
If you use these blocks directly in your models, there is no compatibility impact.
However, if you use these blocks as composite component members in Simscape
language, you might need to update your code to use the new parameter names in the
block source.
Block
Old Parameter Name
New Parameter Name
PS Table Lookup (1D)
x_t
x
PS Table Lookup (1D)
y_t
f
3-17
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
Block
Old Parameter Name
New Parameter Name
PS Table Lookup (2D)
x_t
x1
PS Table Lookup (2D)
y_t
x2
PS Table Lookup (2D)
z_t
f
Validation of Signal Units: Ensure consistent units specification on
Simulink signals connected to Simscape physical networks
You can now specify physical units on Simulink signals. For details, see Simulink Units:
Specify, visualize, and check consistency of units on interfaces.
If you specify physical units on a Simulink signal connected to a Simulink-PS Converter
or a PS-Simulink Converter block, this unit must be consistent with the unit specified
inside the block. On a Simulink-PS Converter block, you specify the unit using the Input
signal unit parameter. On a PS-Simulink Converter block, you specify the unit using
the Output signal unit parameter. If the parameter value does not match the physical
unit of the Simulink signal connected to the block, you get a warning.
If the block parameter value is 1, it matches the Simulink signal unit designated as 1.
Compatibility Considerations
The default Simscape unit registry has been made consistent with the Simulink unit
database. If the Simscape and Simulink databases used different symbols for the same
unit, both symbols are now in the Simscape database and you can use either one.
Quantity
Unit
Simscape Symbol
Simulink Symbol
Energy
British thermal unit Btu
Btu_IT
Power
Horsepower
HP
HP_DIN
Viscosity absolute
Poise
Poise
P
Viscosity kinematic
Newt
Newt
newt
In several cases, there was a conflict between the Simulink and Simscape symbols.
3-18
Unit
Simscape Symbol
Simulink Symbol
Coulomb
c
C
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Unit
Simscape Symbol
Simulink Symbol
Degree Celsius
C
degC
Degree Rankine
R
degR
Roentgen
-
R
This conflict resulted in the following changes to Simscape units, with potential
compatibility impact:
• The C symbol for degree Celsius has been replaced with degC. Both c and C now
indicate Coulomb.
• The R symbol for degree Rankine has been replaced with degR. Symbol R now
indicates roentgen.
• The Fh symbol was not part of the conflict, but the degF symbol has been added for
consistency. You can use either one for degree Fahrenheit.
If your legacy models use Simulink-PS Converter or PS-Simulink Converter blocks with
unit specified as C or R, you get a compile-time error. Open the Upgrade Advisor, select
Check model for block upgrade issues, and click Run This Check to find and
modify all blocks with outdated units.
If there is no conflict between the old and new symbols (for example, Btu and Btu_IT),
your legacy models do not need to be updated. Only the new symbol (in this case,
Btu_IT) will appear in the dialog box drop-downs for commensurate units, but you can
type Btu in unit expressions. However, MathWorks recommends that you use the new
symbol names going forward.
To distinguish between absolute and relative temperatures, Simscape unit manager
lets you select whether to apply affine conversion (see Thermal Unit Conversions). By
contrast, Simulink database contains a separate set of temperature units to indicate
relative temperatures: deltaK, deltadegC, deltadegF, deltadegR. These units have
also been added to the Simscape database. If you use them, affine conversion does not
apply. The old method, of specifying regular temperature units and selecting whether to
apply the affine conversion, works without change; however, you can get warnings about
unit mismatch from the Simulink side of your model.
If you add a new unit to your unit registry, by using the pm_addunit function, and your
unit definition conflicts with the one in the Simulink database, you will get a warning
that the Simscape unit is not compatible with the Simulink unit database. If you add a
unit that does not exist in the Simulink database, you will get a warning about undefined
3-19
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
unit. Note that this warning applies only to the Simulink database; the Simscape
physical network works as expected. For information on how to turn off these warnings,
see Working with Simulink Units.
Another issue affects legacy models where multiple Simulink-PS Converter or PSSimulink Converter blocks share the same Simulink signal. For example, you can no
longer connect multiple Simulink-PS Converter blocks with different units to the same
Simulink source, such as a Constant block.
Thermal Resistor block in the Electrical Elements library
The Thermal Resistor block represents a temperature-dependent resistor. When the
temperature at the thermal port is T, the resistance is , where 0 is the nominal resistance
at the reference temperature 0 and is the temperature coefficient.
This block was previously part of the Simscape Electronics™ Passive Devices library.
The ability of the Simscape Electronics Resistor block to model thermal effects,
introduced in R2015b, rendered the Thermal Resistor block superfluous. Therefore, this
block has now been moved to the Simscape Electrical Elements library.
There is no compatibility impact on existing models.
Mass Flow Rate & Thermal Flux Sensor (TL) block renamed
The energy flow rate replaces the thermal flux as a Through variable in the Foundation
Thermal Liquid domain. To reflect this change, the Mass Flow Rate & Thermal Flux
Sensor (TL) block has been renamed to Mass & Energy Flow Rate Sensor (TL). The
updated block senses not the thermal energy flow rate but the total energy flow rate—the
sum of thermal energy and pressure-volume work terms.
Compatibility Considerations
The variable measured through port Phi of the Mass & Energy Flow Rate Sensor (TL)
block has changed. Older models dependent on thermal energy flow rate measurements
can give inaccurate simulation results.
Thermal Liquid volumetric flow rate source and sensor blocks
The Thermal Liquid library now provides source and sensor blocks for setting and
sensing volumetric flow rates:
3-20
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
• Volumetric Flow Rate Source (TL)
• Controlled Volumetric Flow Rate Source (TL)
• Volumetric Flow Rate Sensor (TL)
The sources are ideal and adiabatic. Friction losses and heat exchange with the source
environment are ignored. Use the Volumetric Flow Rate Source (TL) block for constant
flow rates and the Controlled Volumetric Flow Rate Source (TL) for variable flow rates.
Custom environment pressure in Thermal Liquid converter blocks
Thermal Liquid converter blocks provide a new option to specify the external
environment pressure. Affected blocks include Translational Mechanical Converter (TL)
and Rotational Mechanical Converter (TL). You can set the environment pressure to
the standard atmospheric value of 0.101325 MPa or to a custom value that you specify.
The environment pressure adds to the total pressure the converters must overcome to
generate force or torque.
Numerical improvements in Thermal Liquid blocks for greater model
fidelity
Various block parameters and equations have changed to provide greater model fidelity.
Changes include:
• Revised Nusselt number calculations in the Pipe (TL) block — In the laminar regime,
the Nusselt number is now a constant. This change reflects the negligible thermal
entrance effects assumed in pipe segments. In the turbulent regime, the Nusselt
number now follows from the Gnielisnki correlation. The new correlation improves
numerical accuracy relative to the Colburn equation that it replaces.
• Scaling of minimum thermal conductance in the Thermal Liquid Settings (TL) block
— The minimum thermal conductance in a thermal liquid network now scales with
component geometry. This parameter sets a lower bound on thermal conductance
which, during flow reversals, helps to smooth out heat flow transitions. The new
geometric scaling enables you to more accurately model slender components with
large aspect ratios.
• Updated discharge coefficient definition in Local Restriction (TL) and Variable Local
Restriction (TL) blocks — The new discharge coefficient parameter relates the actual
mass flow rate to its theoretical value according to the expression
3-21
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2016a
m
& = C d Sr
2 r Dp
1 - ( Sr / S )
2
,
where:
•
& is the mass flow rate.
m
•
d
is the discharge coefficient.
•
r
is the restriction area.
• is the pipe area.
• is the liquid density.
• is the pressure drop across the restriction.
The previous definition corresponds to the more aptly named flow coefficient, given by
& = Cv Sr 2 rDp
m
where v is the flow coefficient. The change in coefficient definition has a negligible
impact on simulation results when the restriction area is less than one quarter of the
adjacent pipe area.
• New cross-sectional area parameter for thermal conduction calculations in the
Rotational Mechanical Converter (TL) block. The block uses the new parameter to
determine the aspect ratio of the converter, , where is the thermal conduction length
and is the specified cross-sectional area. The thermal conduction length is assumed
equal to the cross-sectional diameter.
Sign reversal of thermal expansion coefficient
The sign of the Isobaric coefficient of thermal expansion parameter in the Thermal
Liquid Settings (TL) block has changed. The updated block automatically reverses the
coefficient sign in older models so you do not have to. The new sign convention is the
same used by the National Institute of Standards and Technology (NIST) in the fluid
properties database REFPROP:
3-22
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
a =
1 Ê ∂V ˆ
1 Ê ∂r ˆ
Á
˜ =- Á
˜ ,
r Ë ∂T ¯ p
V Ë ∂T ¯ p
where:
• α is the isobaric coefficient of thermal expansion
• V is the volume
• T is the temperature
• p is the pressure
• ρ is the density
Functionality being removed or changed
Simscape Language
Keyword Name
What Happens When Use This Instead
You Use the Keyword?
Hidden attribute for Still runs
members
ExternalAccess
Compatibility
Considerations
See Compatibility
Considerations
under “Improved
attributes for
member visibility
and access ” on page
3-5.
3-23
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2015aSP1
Version: 3.13.1
Bug Fixes
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2015b
Version: 3.14
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2015b
Simscape Language
Units handling refinements in Simscape language
To increase robustness and consistency of simulation results, several semantic changes
have been made with respect to how Simscape language handles math operations on
physical units:
• When you declare a member as a value with unit, or use {value,'unit'} in
equations, value must be a unitless expression. In previous releases, the value
expression could already have a unit, which sometimes resulted in double conversions
by the unit manager.
• Arguments passed to transcendental functions must be dimensionless. Examples of
transcendental functions include the exponential function, the logarithm, and the
trigonometric functions. Previously, these functions accepted a value with unit as an
argument, but did not handle units. For example, if is pressure, log(p) would take
a logarithm of the value but ignore the units, and therefore have different results
depending on whether pressure was defined in Pa or MPa.
Now you have to pass a dimensionless argument to these functions, by converting to
units of 1 before applying the function. In the example above, instead of log(p), you
now have to use log(value(p,'Pa')), or equivalently log(p/{1,'Pa'}).
Compatibility Considerations
When you rebuild your custom libraries for use with R2015b, you can get ssc_build
errors if your Simscape files violate the new, stricter, rules of units handling. Modify the
source file to convert to units of 1, as described above.
5-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Foundation Library and Simulation
Two-Phase Fluid domain and block library
The Foundation library now contains a two-phase fluid domain and Two-Phase Fluid
block library. This library contains chambers, reservoirs, local restrictions, and energy
converters, sources and sensors, as well as a Two-Phase Fluid Properties (2P) block,
which controls fluid properties for the attached circuit.
Use these blocks for modeling two-phase fluid systems, where the working agent is part
liquid and part vapor.
For more information, see the block reference pages. See also Two-Phase Fluid Domain
for information on the two-phase fluid domain definition.
Variable priority option None for initialization
Variable initialization priority None is now available in block dialogs, in addition to
High and Low. In previous releases, all three values were available only in the Simscape
language, when writing component files. When using a block, you could only specify High
or Low priority, or leave the variable as Unused. With this change, the options available
in the Variables tab of the block dialog box align exactly with the options available in
the Simscape file.
Each variable has a beginning value before the initialization algorithm finds consistent
values for the system of equations. When the variable priority is None, the algorithm
starts at this beginning value but does not remember the beginning value as the
algorithm finds a solution. When the variable priority is Low, the beginning value
becomes a target for the algorithm and the algorithm tries to stay close to the target.
When the variable priority is High, the beginning value becomes a target for the
algorithm and the algorithm tries to meet the target exactly.
The component author specifies default initialization priority, beginning value, and unit
for each variable in the Simscape file. When using the block, you can override these
default settings for any of the public variables (that is, variables that appear on the
Variables tab of the block dialog box) by selecting the Override check box for that
variable and specifying your own values.
If you clear the Override check box next to a variable name, then its Priority,
Beginning Value, and Unit fields switch back to defaults specified in the component
5-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2015b
file. However, if you select the check box again, these fields will retain their last specified
value for when they were overridden.
Periodic Operators library
The Physical Signals library now has a Periodic Operators sublibrary, which contains the
following blocks:
• PS Constant Offset Estimator
• PS Harmonic Estimator (Amplitude, Phase)
• PS Harmonic Estimator (Real, Imaginary)
• PS RMS Estimator
Use these blocks for various aspects of periodic signal measurements.
Speed and efficiency improvements for simulation of switched linear
systems
Performance optimizations implemented in this release allow switched linear models to
run faster in desktop simulation, in both Normal and Accelerator modes. The average
simulation time for switched linear systems is around 1.3x faster than in previous
release. The actual speedup varies depending on the particular model.
To take advantage of the new optimizations, switched linear models:
• Can not contain blocks that register sample times, such as Counter or Random
Number blocks.
• Can not log simulation statistics. Open the Configuration Parameters dialog and, on
the Simscape pane, clear the Log simulation statistics check box.
Domain-specific line style propagation through block icons
Domain-specific line styling, introduced in R2014b, now applies to the block icons as well.
Relevant parts of each block icon assume domain-specific line styles and colors, with the
connection lines continuing into the icon, so that the block diagram closely resembles a
circuit schematic. The connection lines now have rounded corners. These enhancements
improve the readability and clarity of block diagrams.
5-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Rotational Inerter and Translational Inerter blocks
The new Rotational Inerter and Translational Inerter blocks represent two-port inertia
in rotational and translational mechanical systems, respectively.
Use these blocks in high performance suspension systems, to decouple weave and roll
modes, or in applications where you need to model a passively tuned mass-spring-damper
response.
Real-Time Performance Advisor checks for physical models
If you have a Simulink Real-Time™ license, the new Execute real-time
application activity mode in Performance Advisor lets you optimize your model for
real-time execution. This mode includes several checks specific to physical models. These
checks are organized in the Simscape checks folder, with subfolders for the add-on
products, such as SimDriveline checks or SimElectronics checks. The top-level
Simscape checks are applicable to all physical models. Each of the subfolders contains
checks that target specific blocks from that add-on product.
To access the checks, in the Performance Advisor window, under Activity, select
Execute real-time application. In the left pane, expand the Real-Time folder,
and then the Simscape checks folder. Run the top-level Simscape checks. If your
model contains blocks from an add-on product, also run the checks in the subfolder
corresponding to that product.
For more information on using the Performance Advisor, see Automated Performance
Optimization.
Real-Time Simulation Documentation Enhancements
The documentation on real-time and hardware-in-the-loop simulation of Simscape
models has been revised and expanded. See Real-Time Simulation.
Variable Viewer link to block diagram renamed
The Variable Viewer option that highlights the relevant block in the block diagram
has been renamed from Highlight block to Go to block, to avoid ambiguity in
SimMechanics™ models.
5-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2015b
When you right-click in the Name column of any row in the Variable Viewer table, a
context menu opens with the following options:
• Go to block — Highlights the corresponding block in the block diagram, opening
the appropriate subsystem if needed. If the row represents a variable, highlights the
parent block for this variable.
• Open block dialog — Opens the corresponding block dialog box (for a variable,
opens the parent block dialog box). This enhancement makes it easy to go from the
Variable Viewer to the Variables tab in the block dialog box, to modify the variable
priorities and targets.
For more information, see Variable Viewer.
Naming schema change within the data logging variable structure
When you enable simulation data logging, the workspace variable containing the logged
data mimics the structure of the model. Nodes within the variable have names that are
derived from the blocks and variables in the model. However, each node has to be a valid
and unique MATLAB identifier, and therefore the block names undergo changes, such as
replacing spaces with underscores.
In previous releases, this name processing also involved a built-in string-to-integer
function that stripped leading zeros from numbers in block names. For example, for a
Resistor block named R0001 in the block diagram, the corresponding logging variable
node was named R1. If your block diagram contained two resistors, R1 and R0001,
then one node was named R1 and the other R2, to satisfy the unique identifier rule.
As a result, the logging variable nodes could have names that did not match the block
diagram.
The current naming schema preserves the leading zeros in numbers included in block
names. In the example above, the node corresponding to resistor R0001 is now named
R0001.
Compatibility Considerations
If your models have blocks with names that contain numbers with leading zeros (such as
R0001), then the names of the corresponding nodes in the data logging structure have
changed compared to the previous release. If you have scripts that rely on these node
names being the same, you need to update them.
5-6
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2015a
Version: 3.13
New Features
Bug Fixes
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2015a
Foundation Library and Simulation
Variable Viewer link to block diagram
The Variable Viewer tool now provides a direct link to the relevant block in the block
diagram.
When you right-click in the Name column of any row in the Variable Viewer table, a
context menu opens with the following options:
• Highlight block — Highlights the corresponding block in the block diagram, opening
the appropriate subsystem if needed. If the row represents a variable, highlights the
parent block for this variable.
• Open block dialog — Opens the corresponding block dialog box (for a variable,
opens the parent block dialog box). This enhancement makes it easy to go from the
Variable Viewer to the Variables tab in the block dialog box, to modify the variable
priorities and targets.
For more information, see Variable Viewer.
Improved solver efficiency for model initialization
The initial conditions solver speed increased significantly in this release without
sacrificing the robustness.
The initial conditions solver works much faster in general. If the initial condition
solve fails, the reaction time is much faster as well. The solver also reacts almost
instantaneously when you press CTRL-C.
Sparkline plots for logged data
You can view sparkline mini-plots of logged simulation data for selected blocks and
variables directly on the model canvas.
Before using this functionality, you must enable data logging, for all or some of the
blocks, and run the simulation. For more information, see Data Logging.
To view the sparkline plots, in the model window, from the top menu bar, select Display
> Simscape > Toggle Sparklines When Clicked. This action adds the check mark
6-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
next to the Toggle Sparklines When Clicked menu option, and you can start selecting
blocks to display sparkline plots of logged data for their variables.
When you select a block you can see sparkline plots for its variables. Hover over the
variable name to see the plot. You can select which variables to plot (the first three are
shown by default).
If you select a block for which simulation data is not being logged, it displays No
variables instead of the sparkline plots. Right-click the block, select Simscape > Log
simulation data, and rerun the simulation.
Repeatedly selecting a block toggles the display of its sparkline plots on and off.
To clear all plots and start again with a clean canvas, select Display > Simscape >
Remove All Sparklines. Then you can select more blocks and variables to display their
sparkline plots.
Repeatedly selecting the Toggle Sparklines When Clicked menu option toggles the
ability to view the sparkline plots for the model on or off, as indicated by the check mark.
For more information, see View Sparkline Plots of Simulation Data.
Data logging for models created using ssc_new
When you create a new model using the ssc_new function, simulation data logging for
this model is now turned on by default. Data logging configuration parameters are
automatically set to the following values:
• Log simulation data — All.
• Log simulation statistics — Off.
• Open viewer after simulation — Off.
• Workspace variable name — simlog.
• Decimation — 1.
• Limit data points — On.
• Data history (last N steps) — 10000.
Using data logging is a best practice for Simscape models because it provides access to
important simulation and analysis tools. For more information, see Data Logging.
6-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2015a
Pressure setting and name change for Thermal Liquid reservoir blocks
The two reservoir blocks in the Thermal Liquid/Elements library serve as reference
points in a pipe network, where you can specify an arbitrary reference temperature. In
previous versions, the pressure in these blocks was always set to atmospheric pressure.
Now you have an option to specify an arbitrary value for the reference pressure, as well
as temperature.
Both blocks now have a new parameter, Reservoir pressure specification, which lets
you select between two values:
• Atmospheric pressure (default)
• Specified pressure — If you select this value, an additional parameter,
Reservoir pressure, appears in the dialog box to let you enter the reference
pressure value.
The block names have been changed:
Old Name
New Name
Temperature Reservoir (TL)
Reservoir (TL)
Controlled Temperature Reservoir (TL)
Controlled Reservoir (TL)
There is no compatibility impact. When you open an existing model containing these
blocks, it is updated automatically to use the new version of the blocks.
New examples
Examples introduced in this version are:
• Lithium-Ion Battery Pack With Fault
• Transmission Line
6-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014b
Version: 3.12
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014b
Simscape Language
Refrigeration example modeling two-phase fluid flow
A new example shows how you can use Simscape language to model two-phase fluid flow.
The example includes a custom two-flow domain and a library of custom components
based on this domain.
To open the custom library, type two_phase_lib at the MATLAB Command prompt.
Double-click any block in the library to open its dialog box, and then click the Source
code link in the block dialog box to open the Simscape source file for this block in the
MATLAB Editor. The custom domain file is located in the same folder as the component
files.
To open the Two-Phase Flow Refrigeration Model built of these custom components, type
ssc_refrigeration at the MATLAB Command prompt.
7-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Foundation Library and Simulation
Domain-specific line styles for representing physical connections
Each Simscape domain now uses a distinct default color and line style for the connection
lines. Physical signal lines now also have a distinct style and color. This enhancement
improves the readability of block diagrams.
Improved interface for connecting Simscape blocks
The following usability enhancements have been made in this release:
• Visual hint for an invalid connection attempt — You cannot connect ports that belong
to different domains, but in previous releases it was not always obvious why the
connection was not being made. Now, as you are trying to connect a Simscape port,
the cursor appearance changes just as it approaches a port or line that belongs to a
different domain, to indicate that the connection here is invalid.
• If you place a Simscape block with two ports (one on each side) over a connection line
that belongs to the appropriate domain, the block gets inserted automatically.
• When you connect Simscape blocks, the ports on either side of the connection line
disappear. Physical signal output ports also disappear. Physical signal input ports
remain, to show the signal direction.
Option to configure logging of Simscape simulation results per block
In previous releases, once you enabled simulation data logging, it included data for the
whole model. The new Use local settings option lets you log data for selected blocks
only. The basic workflow is as follows:
1
Enable simulation data logging on a block-by-block basis. In the model window, from
the top menu bar, select Simulation > Model Configuration Parameters. In the
Configuration Parameters dialog box, in the left pane, select Simscape, then set the
Log simulation data parameter to Use local settings. Click OK.
2
Select the blocks in your model by right-clicking on each block and then, from the
context menu, selecting Simscape > Log simulation data. A check mark appears
in front of the Log simulation data option.
3
Simulate the model. When the simulation is done, the simulation data log contains
only the data from the selected blocks.
7-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014b
To stop logging data for a previously selected block, right-click on it and select Simscape
> Log simulation data again to remove the check mark.
If you set the Log simulation data parameter to All, the simulation log will
contain data from the whole model, regardless of the block selections. Setting the Log
simulation data parameter to None disables data logging for the whole model.
Flat view option and improved diagnostics for Variable Viewer
You can now control the number of rows in the Variable Viewer by switching between the
tree view (the default) and the flat view. By default, the Variable Viewer opens in tree
view, with variable nodes grouped under the parent port, block, and subsystem nodes.
To switch to the flat view, click
in the Variable Viewer toolbar. The table now
contains one row per variable, with the Name column showing the full path to the
variable, in the following format:
SubsystemName --> BlockName --> PortName --> VariableName
If the Variable Viewer is in flat view, the buttons that expand and collapse nodes are
disabled. To switch back to the tree view, click
in the Variable Viewer toolbar.
Another improvement is better diagnostics of the overall status. A message in the
bottom-right corner of the Variable Viewer window tells you whether the viewer displays
the variables at start, imported variables (when you load an initial state or SimState), or
after update diagram (when the previously computed actual values become unavailable).
Simscape Results Explorer
Simscape Results Explorer is an interactive tool that lets you navigate and plot the
simulation data logging results. This tool is an enhanced version of the Simscape
Simulation Results Explorer (ssc_explore.m) previously posted on MATLAB Central.
It is now part of the product. To use the tool:
7-4
1
In the model window, from the top menu bar, select Simulation > Model
Configuration Parameters. In the Configuration Parameters dialog box, in the
left pane, select Simscape.
2
Set the Log simulation data parameter to All or Use local settings, to
enable data logging.
3
Select the Open viewer after simulation check box. Click OK.
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
4
If using local settings, select the blocks in your model as described in “Option to
configure logging of Simscape simulation results per block” on page 7-3.
5
Simulate the model. When the simulation is done, the Simscape Results Explorer
window opens. It contains the simulation log tree hierarchy in the left pane. When
you click on a node in the left pane, the corresponding plot appears in the right pane.
You can control whether the Simscape Results Explorer window is reused when you
rerun the simulation, or a new window is opened after the next simulation run, by
linking and unlinking the window.
When you first open the Simscape Results Explorer window, it is linked to the current
MATLAB session. This means that when you run a new simulation, the results in the
window will be overwritten. To retain the current results and open a new window after
the next simulation, click the
button located in the toolbar above the left pane. The
button appearance changes to
and, when the new window opens after simulation,
that window will be linked to the session. Only one window can be linked to the session,
so if you have multiple windows open, linking one of them (by clicking on its
unlinks the previous one.
button)
Simscape logging into Simulink single output
If you select the Save simulation output as single object check box on the Data
Import/Export pane of the Configuration Parameters dialog box, Simscape log data
will now be part of the single output object. In this case, it is not stored as a separate
workspace variable.
If the Save simulation output as single object check box is not selected, simulation
data is stored in the current workspace, with the name of the workspace variable
specified by the Workspace variable name configuration parameter. The default
variable name is simlog.
This enhancement makes Simscape data logging compatible with the parfor command.
For more information, see Save simulation output as single object.
Compatibility Considerations
In previous releases, simulation data was stored as a variable in the base workspace.
Now, if the single output is not enabled (which is the default), this variable is stored in
7-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014b
the current workspace, instead of the base workspace. If the single output is enabled,
simulation data becomes part of the single output object and is not stored as a separate
workspace variable. Therefore, if you have created custom scripts or functions that rely
on accessing the simlog variable in the base workspace, you will have to modify them
accordingly.
Simscape logging integration with Simulation Data Inspector
You can now configure your model to automatically record Simscape logging data, along
with the rest of simulation data obtained from a model run, using the Simulation Data
Inspector. The basic workflow is as follows:
1
Set up your model to log simulation data. In the model window, from the top
menu bar, select Simulation > Model Configuration Parameters. In the
Configuration Parameters dialog box, in the left pane, select Simscape, then set
the Log simulation data parameter to All or Use local settings. If using
local settings, select the blocks to log data from, as described in “Option to configure
logging of Simscape simulation results per block” on page 7-3.
2
Enable data recording. In the Configuration Parameters dialog box, in the left pane,
select Data Import/Export, then select the Record logged workspace data in
Simulation Data Inspector check box.
3
Simulate the model. When the simulation is done, a notification bar appears in the
Simulink Editor.
4
In the notification bar, click the link to open the Simulation Data Inspector and view
the results.
For detailed information on how to configure and use the Simulation Data Inspector, see
Inspect Signal Data with Simulation Data Inspector.
Infinite resistance and port terminator blocks
Infinite resistance blocks let you specify initial difference for the appropriate Across
variable (such as voltage, pressure, temperature) between two nodes without affecting
model equations. The following new blocks in Foundation library implement infinite
resistance for their respective domains:
• Infinite Flow Resistance (TL)
• Infinite Hydraulic Resistance
7-6
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
• Infinite Pneumatic Resistance
• Infinite Resistance
• Infinite Thermal Resistance
These blocks have no parameters, but their Variables tab lets you set the priority and
initial target value for the appropriate Across variable.
Similarly, the conserving port terminator blocks now display the Variables tab, which
lets you set the priority and initial target value for the appropriate Across variable at a
node. The affected blocks are:
• Cap (TL)
• Hydraulic Cap
• Open Circuit
• Perfect Insulator
• Rotational Free End
• Translational Free End
The PS Terminator block has been added to the Sinks sublibrary of the Physical Signals
library. It lets you cap physical signal output ports that do not connect to other blocks.
Unlike conserving ports in physical modeling, or Simulink output ports, unconnected
physical signal output ports do not generate warnings. However, you can use a PS
Terminator block for clarity, to indicate that the signal was not inadvertently left
unconnected.
Performance improvements for linear systems in Normal and Accelerator
modes
Linear optimizations have been extended to include affine systems (for example, models
containing blocks like DC Voltage Source), which results in faster simulation. Also,
increased efficiency of generated code for linear and affine systems provides improved
performance in Accelerator mode and for code generation.
7-7
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014a
Version: 3.11
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014a
Simscape Language
ssc_build library build process that no longer requires C compiler
In previous releases, the library build process, whether performed using the ssc_build
command or using the ssc_mirror command with the buildmirror flag set to true,
required a C compiler. Before running either of these commands for the first time, you
had to set up your compiler by running mex -setup.
In-memory execution of the library build process, implemented in this release, increases
the process speed and eliminates the need for a C compiler. Therefore, you no longer need
to have a C compiler available on your machine in order to build a custom block library.
priority attribute for setting relative priority of variable target values
during initialization
The new initialization process, implemented in this release, involves block-level variable
initialization. That is, a Simscape block dialog box now has an additional Variables
tab, which lists all the public variables specified in the underlying component file, along
with the initialization priority, target initial value, and unit of each variable. The block
user can change the variable priority and target, prior to simulation, to affect the model
initialization. The default values for variable priority, target value, and unit come from
the variable declaration in the component file.
To enable the block author to specify default priority for a variable, a new attribute
is now available. The priority attribute can have one of the three values:
priority.high, priority.low, and priority.none. The default is priority.none,
which is equivalent to leaving out the priority attribute entirely.
To specify a high or low default priority for a component variable, declare the variable
as a field array. For example, the following declaration initializes variable t (spring
deformation) as 0 mm, with high priority:
variables
t = { value = { 0 , 'mm' }, priority = priority.high }; % Spring deformation
end
The old way of declaring variables still works. In fact, leaving out the priority
attribute (that is, using priority.none) is suitable in most cases. The block user can
8-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
control the variable initialization priority, as needed, by using the Variables tab of the
block dialog box.
For example, you can declare the same variable t as follows:
variables
t = { 0 , 'mm' }; % Spring deformation
end
In this case, the Variables tab in the block dialog box will have the Spring
deformation variable listed initially as Unused (which means its priority and target are
not used in the initialization process). The block user can modify the variable priority,
as well as the target value and unit, in the Variables tab of the block dialog box prior to
simulation.
If there are no top-level public variables declared in the component file (for example, if
the top-level variables are declared as hidden), the Variables tab does not appear in the
block dialog box. The same is true for composite components, because they also have no
top-level public variables.
For more information on block-level variable initialization, see “Variables tab for
specifying target value and priority for new initialization process” on page 8-5.
Script for replacing through and across statements with branches
and equations
The ssc_update script is now available to help you update the legacy component
files that contain across and through statements. The scripts replaces the through
statements with the corresponding branches section, and adds the equations equivalent
to the across statements to the equations section of the file.
For more information on the old and new syntax, see Compatibility Considerations under
“branches section for defining the relationship between component Through variables
and nodes” on page 9-2.
To run the script, at the MATLAB command prompt, type:
ssc_update
where is the name of a top-level package directory, without the leading + character. If
you run the ssc_update command from inside the package directory structure, you
8-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014a
can omit the argument. The script updates all the legacy component files located in the
package. For more information, see ssc_update.
8-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Foundation Library and Simulation
Variables tab for specifying target value and priority for new
initialization process
New initialization process, implemented in this release, gives you more control over
model initialization. Most of the Foundation library blocks now have a new Variables
tab, which lists all the public variables specified in the underlying component file, along
with priority, initial value, and unit. In most cases, the default value for each of these
is Unused. Once you select the check box next to a variable name, you can specify its
priority (High or Low), target initial value, and unit.
If the underlying component has no top-level public variables (such as a composite
component, or one with the top-level variables declared as hidden), then the block dialog
box does not have the Variables tab. For that reason, the Utilities library blocks, most
of the Foundation library sensors and sources, and the absolute majority of blocks in the
add-on products are not affected by this change.
The values you specify during block-level variable initialization are not the actual values
of the respective variables, but rather their target values at the beginning of simulation
(). Depending on the results of the initial conditions solve, some of these targets may or
may not be satisfied. The solver tries to satisfy the high-priority targets first, then the
low-priority ones:
• At first, the solver tries to find a solution where all the high-priority variable
targets are met exactly, and the low-priority targets are approximated as closely as
possible. If the solution is found during this stage, it satisfies all the high-priority
targets. Some of the low-priority targets might also be met exactly, the others are
approximated.
• If the solver cannot find a solution during the first stage, it issues a warning and
enters the second stage, where High priority is relaxed to Low. That is, the solver
tries to find a solution by approximating both the high-priority and the low-priority
targets as closely as possible.
After you initialize the block variables and prior to simulating the model, you can open
the Variable Viewer to see which of the variable targets have been satisfied. For more
information on block-level variable initialization and Variable Viewer, see Variable
Initialization.
8-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014a
Compatibility Considerations
In previous releases, several Foundation library blocks contained parameters
that let you specify an initial value for an internal block variable at the start of
simulation. These parameters have now been removed. The following table lists the
initialization parameters that have been removed from block dialogs and the names of
the corresponding block variables:
Block Name
Parameter Name
Variable Name
Capacitor
Initial voltage
Capacitor voltage
Constant Volume Chamber
(TL)
Fluid initial pressure
Pressure
Fluid initial temperature Temperature
Constant Volume Hydraulic Initial pressure
Chamber
Pressure (gauge)
Constant Volume
Pneumatic Chamber
Initial pressure
Pressure
Initial temperature
Temperature
Fluid Inertia
Initial flow rate
Flow rate
Hydraulic Piston Chamber
Initial pressure
Pressure (gauge)
Inductor
Initial current
Inductor current
Inertia
Initial velocity
Rotational velocity
Mass
Initial velocity
Velocity
Mutual Inductor
Winding 1 initial current Primary current
Winding 2 initial current Secondary current
Pneumatic Piston Chamber Initial pressure
8-6
Pressure
Initial temperature
Temperature
Rotational Hard Stop
Initial angular position
Angular position
Rotational Spring
Initial deformation
Deformation
Rotary Pneumatic Piston
Chamber
Initial pressure
Pressure
Initial temperature
Temperature
Thermal Mass
Initial temperature
Temperature
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Block Name
Parameter Name
Variable Name
Translational Hard Stop
Initial position
Position
Translational Spring
Initial deformation
Deformation
Variable Hydraulic
Chamber
Initial pressure
Pressure (gauge)
Legacy models using these blocks are not affected by this change. If a block had an
initialization parameter, then, once you open the model in the current release, this
parameter value is automatically mapped to the corresponding block variable, which
assumes it as the target value with High priority. The simulation results stay the same.
However, if you have a custom composite component (written in Simscape language) that
uses one of these Foundation library blocks and references an initialization parameter,
trying to build the library or simulate a model containing the custom block produces an
error, because the referenced parameter is no longer available.
For example, if you have a custom composite component that contains an Inertia block:
component DC_Motor
[...]
parameters
motor_inertia = { 0.01, 'g*cm^2' };
% Inertia
init_velocity = { 0, 'rad/s' };
% Initial velocity
[...]
end
components(Hidden=true)
motorInertia = foundation.mechanical.rotational.inertia(inertia = motor_inertia,
initial_velocity = init_velocity);
[...]
end
[...]
end
ssc_build will produce an error similar to the following:
Error using ne_updatelibraryitem>lBuild (line 35)
File: C:\Work\libraries\+MyElecLibrary\DC_Motor.ssc
Line: 32 Reference to parameter
'initial_velocity' is invalid.
Update the custom component by removing all references to the initialization parameter:
component DC_Motor
[...]
parameters
motor_inertia = { 0.01, 'g*cm^2' };
% Inertia
[...]
end
components(Hidden=true)
motorInertia = foundation.mechanical.rotational.inertia(inertia = motor_inertia);
[...]
end
8-7
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014a
[...]
end
Variable Viewer for analyzing results of new initialization process
A new analysis tool, available for models containing Simscape blocks and blocks
from add-on products, provides the back end for the block-level variable initialization
by letting you view the variable targets, priority, and actual initial values prior to
simulation. To open the tool, in the top menu bar of the model window, select Analysis >
Simscape > Variable Viewer. For more information, see Variable Viewer.
Statistics Viewer that displays variable source and number of eliminated
variables
The Statistics Viewer analysis tool has the following enhancements:
• New top-level statistic, 1-D/3-D Interface, lists the connections between the two
types of physical networks. It appears only for models that connect blocks from
SimMechanics Second Generation library to Simscape blocks, or blocks from other
add-on products.
• The new Sources section lists variable sources for the selected statistic. If you select
a connection under the 1-D/3-D Interface statistic category, the Sources section
lists the source and destination for this connection. If you select a statistic with a
nonzero value under the 1-D Physical System category, the Sources section lists all
the variables that fall under this statistic.
For each variable, the Source column contains the full path to the variable, starting
from the top-level model, with a link to the relevant block. If you click the link in the
Source column, the corresponding block is highlighted in the block diagram. The
Value column contains the name of the variable, as it would appear in the Variables
tab of the block dialog box.
• Additional statistics under the 1-D Physical System category: Number of
eliminated variables (further categorized as algebraic and differential variables)
and Number of dynamic variable constraints. Eliminated variables are
continuous variables that are eliminated during optimization and are not seen by the
solver. Dynamic variable constraints are constraints involving only dynamic variables
and inputs. Such constraints result in Index-2 differential algebraic equations and
therefore can cause numerical difficulties or slow down your simulation.
For more information, see Model Statistics.
8-8
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Fundamental Reluctance block
The new Fundamental Reluctance block in the Magnetic Elements library provides a
simplified model of a magnetic reluctance, that is, a component that resists flux flow.
Unlike the Reluctance block, which computes reluctance based on the geometry of the
section being modeled, the Fundamental Reluctance block lets you specify a value of
reluctance directly as a block parameter.
Hydro-mechanical converter blocks with fluid compressibility option
The Rotational Hydro-Mechanical Converter and Translational Hydro-Mechanical
Converter blocks now contain a drop-down Compressibility parameter, with the default
value Off. If you select On, additional parameters appear in the block dialog to let you
account for fluid compressibility within the converter block itself. In previous releases,
you had to connect a converter to a Hydraulic Piston Chamber block to account for fluid
compressibility.
Compatibility Considerations
Existing models are not affected by this change, because compressibility in converters is
off by default. However, this change makes the Hydraulic Piston Chamber block obsolete.
MathWorks recommends that you specify fluid compressibility directly in the converter
blocks, because the new method provides more accurate results and also because the
Hydraulic Piston Chamber block may be removed in a future release.
Handling of pressure or temperature below absolute zero during
simulation
You can now set the models that use the hydraulic domain to either warn or stop
simulating with an error when absolute pressures fall below absolute zero. The default
behavior is to stop simulating with an error, which is the same as in previous releases.
You can change this by using the Custom Hydraulic Fluid block, or the Hydraulic Fluid
block (available with SimHydraulics® block libraries), to have the simulation continue
with a warning. See the block reference pages for details.
You can also set the models that use the pneumatic domain to either warn or stop
simulating with an error when pressures or temperatures fall below absolute zero. The
default behavior is to stop simulating with an error. This check was not performed during
simulation in previous releases. You can change the default behavior by using the Gas
8-9
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2014a
Properties block, to have the simulation continue with a warning. See the block reference
page for details.
Input filtering options for 1-D/3-D connections
The Solver Configuration block now lets you control whether input filtering is applied
automatically for models that connect blocks from SimMechanics Second Generation
library to Simscape blocks, or blocks from other add-on products. It also lets you specify
a global filtering time constant value for all the 1-D/3-D connections within the network.
See the block reference page for details.
Software-in-the-loop simulation for physical models
In previous releases, software-in-the-loop (SIL) simulation was not supported for models
containing Simscape blocks or blocks from the add-on products. This limitation is now
removed.
Change in default settings for ssc_new
The ssc_new function, which creates a new Simscape model populated by required and
commonly used blocks, now uses a different default solver and absolute tolerance. Here is
the summary of changes:
Old setting
New setting
Solver
ode15s (stiff/NDF)
ode23t (mod. stiff/
Trapezoidal)
Absolute
tolerance
auto
1e-3
Existing models are not affected. When you create new models with ssc_new, they will
use the new settings. For more information, see the ssc_new reference page.
Functionality being removed or changed
8-10
Simscape Language
Keyword Name
What Happens When Use This Instead
You Use the Keyword?
Compatibility
Considerations
across
Still runs
Run ssc_update
to update the
Create equivalent
equations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Simscape Language
Keyword Name
What Happens When Use This Instead
You Use the Keyword?
Compatibility
Considerations
components in an
existing package. See
“Script for replacing
through and
across statements
with branches and
equations” on page
8-3.
through
Still runs
Run ssc_update
to update the
components in an
existing package. See
“Script for replacing
through and
across statements
with branches and
equations” on page
8-3.
branches
8-11
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013b
Version: 3.10
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013b
Simscape Language
branches section for defining the relationship between component
Through variables and nodes
In previous releases, the Through and Across variables in a component file were
connected to the domain Through and Across variables in the setup section, using the
through and across statements. The syntax of these statements was nonintuitive and
somewhat confusing.
Starting in this release, define the relationship between the Through variables by using
the new branches section, located after the setup section in the component file. The
branches section starts with the branches keyword, contains one or more branch
statements, and ends with the end keyword.
Each branch statement has the syntax:
a : node1.a -> node2.a;
which clearly indicates direction, from node1 to node2. Therefore, a is subtracted
from the conserving equation identified by node1.a, and a is added to the conserving
equation identified by node2.a. If the component has multiple nodes, indicate branches
by writing multiple statements in the branches section. For syntax and examples, see
the branches reference page.
To establish the relationship between the Across variables, use the equations section
of the component file. Add an equation that connects the component Across variable
with the respective variables at the component nodes. If there is more than one Across
variable, add multiple equations, connecting each variable with its respective nodes.
For more information, see Defining Relationship Between Component Variables and
Nodes.
Compatibility Considerations
You do not currently need to update the existing component files. The across and
through statements compile without warnings. In a future release, they will start to
produce warnings when you attempt to build the component. Eventually they will be
removed. When writing new component files, use the new syntax.
9-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
If you want to update your existing component files, the following table summarizes the
old and new syntax.
Old Syntax
New Syntax
through( a, node1.a, node2.a );
a : node1.a -> node2.a ;
across( a, node1.a, node2.a );
a == node1.a - node2.a ;
For example, suppose you have an electrical component that uses the old syntax:
component my_resistor
nodes
p = foundation.electrical.electrical;
n = foundation.electrical.electrical;
end
variables
i = { 0, 'A' };
v = { 0, 'V' };
end
parameters
R = { 1, 'Ohm' };
% Resistance
end
function setup
across( v, p.v, n.v ); % voltage across
through( i, p.i, n.i ); % current through
end
equations
v == i*R;
end
end
Here is the same component rewritten using the new syntax:
component my_resistor
nodes
p = foundation.electrical.electrical;
n = foundation.electrical.electrical;
end
variables
i = { 0, 'A' };
v = { 0, 'V' };
end
parameters
R = { 1, 'Ohm' }; % Resistance
9-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013b
end
branches
i : p.i -> n.i ;
end
equations
v == p.v - n.v;
v == i*R;
end
end
% current through
% voltage across
import statement enabling simplified access to other component classes
With the introduction of composite components in R2012b, class member declarations
now include user-defined types, that is, component classes. An import mechanism
provides a convenient means to accessing classes defined in different scopes, with the
following benefits:
• Allows access to model class names defined in other scopes without a fully qualified
reference
• Provides a simple and explicit view of dependencies on other packages
The import statement can have the following syntax:
import package_or_class;
or
import package.*
The first syntax is a qualified import, which imports a specific package or class. The
second one is an unqualified import, which imports all subpackages and classes under
the specified package.
For more information, see Importing Domain and Component Classes.
connect statement support for vector and matrix physical signals
Simscape language now supports nonscalar (vector-valued or matrix-valued) physical
signals in connect statements. For more information, see Nonscalar Physical Signal
Connections.
9-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Foundation Library and Simulation
Thermal Liquid domain and block library
The Foundation library now contains a thermal liquid domain and Thermal Liquid block
library. This library contains thermohydraulic elements, such as chambers, reservoirs,
local restrictions, and hydro-mechanical converters. It also contains thermal liquid
sources and sensors, as well as a Thermal Liquid Settings (TL) block, which controls
thermal liquid domain properties for the attached circuit.
Use these blocks for modeling applications such as:
• Transportation of heated liquid in pipeline networks
• Actuator warm-up due to viscous stresses
• Heat generation and dissipation in complex systems, such as aircraft hydraulic
systems and associated heat exchangers
For more information, see the block reference pages. See also Thermal Liquid Domain for
information on the thermal liquid domain definition. The Across variables are pressure
and temperature, and the Through variables are mass flow rate and thermal flux. Note
that the product of each pair of the Through and Across variables (pressure and mass
flow rate, temperature and thermal flux) is not power, and therefore these result in a
pseudo-bond graph.
Simscape model statistics viewer
A new analysis tool, available for models containing Simscape blocks and blocks from
add-on products, lets you view Simscape statistics, such as the number of continuous and
discrete variables, number of zero-crossing signals, and number of joints and constraints.
To open the tool, in the top menu bar of the model window, select Analysis > Simscape
> Statistics Viewer.
For more information, see Simscape Model Statistics.
Removal of laminar-turbulent zero-crossings in hydraulic blocks
Hydraulic blocks in the Foundation library no longer produce zero-crossings upon
transition between the laminar and turbulent regimes during simulation. This
enhancement results in increased simulation efficiency for hydraulic models.
9-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013b
New examples
Examples introduced in this version are:
• Hydraulic Fluid Warming due to Losses
• Optimal Pipeline Geometry for Heated Oil Transportation
• Water Hammer Effect
Functionality being removed or changed
9-6
Simscape Language
Keyword Name
What Happens When Use This Instead
You Use the Keyword?
Compatibility
Considerations
across
Still runs
Create equivalent
equations
See Compatibility
Considerations
under “branches
section for defining
the relationship
between component
Through variables
and nodes” on page
9-2.
through
Still runs
branches
See Compatibility
Considerations
under “branches
section for defining
the relationship
between component
Through variables
and nodes” on page
9-2.
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013a
Version: 3.9
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013a
Simscape Language
Variable-size domain parameters
Variable-size component parameters have been implemented in Release R2012a,
to support the tablelookup function. You can now declare variable-size domain
parameters and propagate them to components. Variable-size parameters are still not
allowed in the component equations section outside of the tablelookup function. For
more information, see Using Lookup Tables in Equations and Propagation of Domain
Parameters.
Vector and matrix physical signals
Simscape language now supports nonscalar (vector-valued or matrix-valued) physical
signals in its inputs and outputs declarations. All signals in such vector or matrix
should have the same units. For example, the following declaration
inputs
I = {zeros(3), 'm/s'}; % :left
end
initializes a component input as a 3-by-3 matrix of linear velocities.
Simulink-PS Converter and PS-Simulink Converter blocks have also been enhanced to
handle vector and matrix physical signals.
10-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Foundation Library and Simulation
Random Number and Uniform Random Number blocks
Two new Physical Signal blocks have been added to the Sources library:
• The Random Number block generates normally (Gaussian) distributed random
numbers.
• The Uniform Random Number block generates uniformly distributed random
numbers.
The block behavior is the same as that of the respective Simulink blocks, except that they
generate a physical signal rather than a unitless Simulink signal.
Perfect Insulator block for thermal domain
The new Perfect Insulator block in the Thermal Elements library models a thermal
element with no thermal mass and perfect insulation. Use this block as an insulation for
thermal ports to prevent heat exchange with the environment and to model an adiabatic
process.
Initialization and diagnostic improvements
When you use local solver in a model, an alternative initialization technique is
automatically employed if the standard initialization techniques fail. This alternative
technique attempts to find consistent states, within numerical tolerance, by taking
a small finite step from the user-specified initial states. Therefore, if the alternative
technique succeeds, a warning is issued to the command line that user-specified initial
conditions may not be satisfied. Employing this alternative technique increases the
initialization robustness, especially when there are nonlinear constraints among dynamic
states of a model.
The missing reference node diagnostics have been improved to include information about
the particular block and variable that needs a reference node. This is especially helpful
when multiple domains are involved in the model.
10-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013a
Model Advisor checks for outdated blocks and for physical unit
consistency
Model Advisor user interface now contains two checks specific to Simscape models:
• Check consistency of block parameter units notifies you about differences
between the declared and the actual settings of block parameter units. The check
is triggered by default when you run Model Advisor on your model. You can also
run this check individually by selecting By Product | Simscape or By Task |
Modeling Physical Systems. The check detects block parameters in which the
specified unit is not directly convertible into the default unit expected by the block.
For example, it alerts you if a block parameter is declared with the unit of rad/
s but the value specified in your pre-R2013a model is in Hz. This situation can be
problematic because of the new unit definition for Hz in R2013a (see “Unit definition
of Hz now consistent with SI” on page 10-5).
After you run the check, a table of results appears in the right pane of the Model
Advisor window. Each cell in the first column of the table contains a link to the
problematic block, and the corresponding cell in the second column contains the name
of parameter in question, the expected unit, and the specified unit.
Clicking on a link highlights the corresponding block in the model. Double-click the
highlighted block, verify the parameter unit setting and correct it, if necessary. Then
save and reload the model.
• Check for outdated Simscape blocks detects a pre-R2013a version of AC Voltage
Source and AC Current Source blocks in your model. The check is triggered by default
when you run Model Advisor. You can also run this check individually by selecting By
Product | Simscape.
After you run the check, a list of links to the outdated blocks appears in the right pane
of the Model Advisor window. Clicking on a link highlights the corresponding block in
the model.
To update the blocks, scroll down the right pane of the Model Advisor window and
click the Update button.
• If the automatic update is successful, the Results box displays a message that all
blocks have been updated to the current Simscape version.
10-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
• If the message says that some of the blocks could not be updated automatically,
rerun the check and manually replace the outdated blocks with the latest version
from the block library.
For more information on using Model Advisor, see Consulting Model Advisor.
Unit definition of Hz now consistent with SI
The unit definition for Hz is now 1/s, in compliance with the SI unit system. In previous
releases, the unit definition for Hz was rev/s, consistent with the definition of frequency
as cycles per second in an electrical context, or revolutions per second in a mechanical
context. The old unit definition allowed you to specify frequency in angular units (such
as rad/s or rpm) and write frequency-dependent equations without requiring the 2*pi
conversion factor. The main reason for changing the Hz unit definition is to give the block
author responsibility for frequency units and their correct interpretation for that block.
While a sinsuisoidal source might reasonably be given a frequency in units of Hz or rpm,
angular frequency has no relevance when frequency refers to a nonrotational periodic
signal such as the frequency of a PWM source.
As a result of the new unit definition for Hz, frequency units and angular velocity units
are no longer directly convertible, and using one instead of the other may result in
unexpected conversion factors applied to the numerical values by the block equations.
Drop-down lists of suggested units in block dialogs have been updated to reflect this
change. For example, if your block has a Frequency parameter with the default unit
of Hz, the drop-down list for this parameter now contains only units directly convertible
to Hz (such as kHz, MHz and GHz) and does not contain the angular velocity units (such
as rpm, deg/s and rad/s). You can still type a unit expression representing angular
frequency into the units combo box, and the block will accept it as commensurate with
the expected parameter unit, but it is your responsibility to make sure that the specified
unit works correctly with the block equations.
For more information, see Units for Angular Velocity and Frequency.
Compatibility Considerations
Two Foundation library blocks, AC Current Source and AC Voltage Source, have
been affected by this change. In previous releases, you could specify the Frequency
parameter for these blocks either in units of Hz or in angular units, such as rad/s or
rpm. Starting with Release R2013a, you must specify the Frequency parameter in units
10-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2013a
of Hz or directly convertible to Hz (such as 1/s, kHz, MHz and GHz) because the internal
equation of the block now uses the 2*pi conversion factor to account for the 1/s unit
definition.
If you have a pre-R2013a model that contains these blocks, update it by running the
Model Advisor check, Check for outdated Simscape blocks, or by using the slupdate
utility, and then save the model. A related Model Advisor check, Check consistency
of block parameter units, notifies you about differences between the declared and
the actual settings of block parameter units. For more information, see “Model Advisor
checks for outdated blocks and for physical unit consistency” on page 10-4.
If you have custom Simscape libraries written in R2012b or earlier, and you have used
Hz, kHz, MHz, and GHz as parameter units, then you will need to update your Simscape
code to take account of the Hz unit change. Previously the Simscape unit manager
automatically converted any value entered in units of Hz into units of rad/s before
computation. Therefore, now you need to introduce a factor of 2*pi into block equations
to convert to rad/s and retain the old functionality.
New format for saving simulation data log objects
Data logging functionality lets you log simulation data to the workspace, in the form of a
workspace variable. As with any workspace variable, you can save the data log to a MATfile, and then load the file into workspace at a later date to query and analyze the data.
Starting with Release R2013a, a new format for saving the data log objects in a MATfile has been introduced. The new format reduces the disk space usage and memory
consumption, and makes it faster to save and load simulation data logs.
Compatibility Considerations
There is no backward incompatibility. That is, you can load previously saved MAT-files
containing simulation data with no restrictions.
However, there is a forward incompatibility. MAT-files containing simulation data log
objects saved in the new format (starting with Release R2013a) cannot be opened in older
versions of MATLAB software (Release R2012b or earlier).
New examples
The following example has been introduced in this version:
10-6
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
• Engine Cooling System
Functionality being removed or changed
Simscape Language
Keyword Name
What Happens When Use This Instead
you use the Keyword?
Compatibility
Considerations
throughs
The change was
variables(Balancing=true)
See “Simscape
introduced in
Language Syntax
Release R2009a. The
Changes” on page
keyword has now
18-3 in Release
been removed, and
R2009a.
using the old syntax
produces an error,
instead of a warning,
when you attempt to
build the component.
10-7
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2012b
Version: 3.8
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2012b
Simscape Language
Connection of components within a Simscape file
In physical modeling, there are two types of models:
• Behavioral — A model that is implemented based on its physical behavior,
described by a system of mathematical equations. An example of a behavioral block
implementation is the Variable Orifice block.
• Composite — A model that is constructed out of other blocks, connected in a certain
way. An example of a composite, or structural, block implementation is the 4-Way
Directional Valve block (available with SimHydraulics block libraries), which is
constructed based on four Variable Orifice blocks.
In previous versions, Simscape language supported only behavioral models, that is,
models defined by equations. To create a model containing multiple interconnected
components, you had to define each component in a separate file, deploy it as a custom
block, and then use masked subsystems in block diagrams to connect these blocks into a
single composite model.
Now, additional language constructs let you create composite models directly in a
Simscape file. A component file may now contain two additional blocks:
• A components declaration block, which begins with a components keyword and
is terminated by an end keyword. This block contains declarations for all the
constituent components. Each component is defined with its full path to the toplevel package directory. Specify the required component parameters by declaring a
corresponding parameter in the top-level parameters declaration block, and then
passing this value on to the constituent component.
For example, the following code includes a Foundation library Resistor block in your
custom component file, with a default resistance of 10 Ohm:
component MyCompositeModel1
...
parameters
p1 = {10, 'Ohm'};
...
end
components(Hidden=true)
r1 = foundation.electrical.elements.resistor(R=p1);
11-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Simscape Language
...
end
...
end
• A connections block, located after the setup section, which begins with a
connections keyword and is terminated by an end keyword. This block contains
information on how the constituent components’ ports are connected to one another,
and to the external inputs, outputs, and nodes of the top-level component.
For example, the following code includes the Foundation library Voltage Sensor and
Electrical Reference blocks in your custom component file, connects the negative port
of the voltage sensor to ground, and connects the physical signal output port of the
voltage sensor to the external output of the composite component, located on the right
side of the resulting block icon:
component MyCompositeModel2
...
outputs
Out = { 0.0, 'V' }; % V:right
...
end
components(Hidden=true)
VoltSensor = foundation.electrical.sensors.voltage;
Grnd = foundation.electrical.elements.reference;
...
end
connections
connect(Grnd.V, VoltSensor.n);
connect(VoltSensor.V, Out);
...
end
end
For more information, see Creating Composite Components.
floor, ceil, fix, and round functions
You can now use the following MATLAB functions in the equations section of the
Simscape file:
• floor performs rounding toward negative infinity.
• ceil performs rounding toward positive infinity.
11-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2012b
• fix performs rounding toward zero.
• round performs rounding toward the nearest integer.
The PS Floor, PS Ceil, and PS Fix blocks in the Physical Signals/Nonlinear Operators
sublibrary of the Foundation library have been reimplemented using the Simscape
language and the corresponding function. The PS Round block has been added to the
Nonlinear Operators sublibrary. It performs rounding toward the nearest integer.
11-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Foundation Library and Simulation
Speed and efficiency improvements for simulation of switched linear
systems
Switched linear systems are systems that have multiple configurations during
simulation, but each configuration is linear. The changes in configuration during
simulation may be due to deployment of switches or other elements. A new specialized
simulator, implemented for switched linear systems, reduces the number of states and
accelerates simulation. The specialized simulator is automatically employed based on the
system structure; you do not have to select or enable it explicitly.
Zero-crossing statistics for Simscape logging
If you log simulation data for a Simscape model, you now have an option to log
simulation statistics, including zero-crossing data. By default, the zero-crossing data
is not logged. If you select the Log simulation statistics check box on the Simscape
pane of the Configuration Parameters dialog box, the simulation log variable contains an
additional SimulationStatistics node for each block that can produce zero crossings.
You can then plot and analyze this data similar to other data logged to the workspace
during simulation.
Counter and Repeating Sequence blocks that facilitate discrete sampling
Two new blocks in the Physical Signals/Sources library facilitate discrete sampling in
physical modeling:
• The Counter block repeatedly increments the output signal by 1 with every time step,
in the range between the minimum (reset) value and the maximum value. You can
optionally specify an initial signal value, different from the reset value, and an initial
time offset. Use this block, in conjunction with other physical signal blocks, to model
discrete behaviors.
• The Repeating Sequence block outputs a periodic piecewise-linear signal. You can
optionally specify an initial signal value and an initial time offset. The repeating
sequence consists of a number of linear segments, connected to each other. Use this
block to generate various types of physical signals, such as pulse, sawtooth, stair, and
so on.
11-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2012b
Open-circuit terminator blocks for electrical, hydraulic, and mechanical
domains in Foundation library
Physical Network block diagrams do not allow unconnected Conserving ports. Previously,
if you wanted to leave a port unconnected (open-circuit) you had to add an extra sensor,
which cluttered the block diagram.
Now the following blocks represent domain-specific open-circuit terminators:
• The Open Circuit block represents an electrical terminal that draws no current. Use
this block to terminate electrical ports that you want to leave open-circuit.
• The Hydraulic Cap block represents a hydraulic plug, that is, a hydraulic port with
zero flow through it. Use this block to terminate hydraulic ports that you want to cap.
• The Rotational Free End block represents a mechanical rotational port that rotates
freely, without torque. Use this block to terminate mechanical rotational ports that
you want to leave unconnected.
• The Translational Free End block represents a mechanical translational port that
moves freely, without force. Use this block to terminate mechanical translational
ports that you want to leave unconnected.
Viewable and customizable source files for additional Foundation library
blocks
In R2009a, many blocks in the Foundation library were implemented using the Simscape
language. In 2012b, most of the remaining blocks have been converted.
You can now view the source files for most of the Foundation library blocks. When you
open the block dialog box, it contains a link:
View source for BlockName
Click this link to open the Simscape source file for the block in the MATLAB Editor. To
customize the block for your application, edit the source file and save it in a package
directory. Some of the features, such as drop-down lists in block dialog boxes, are not yet
available for custom blocks. For more information on packaging Simscape source files,
see Simscape File Deployment.
11-6
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Compatibility Considerations
The PS Math Function block now issues a simulation-time error when the input falls
out of the expected domain for the particular function used. For example, if set to sqrt,
the PS Math Function block now issues an error if it receives negative input during
simulation.
New examples
Examples introduced in this version are:
• Lithium Battery Cell - One RC-Branch Equivalent Circuit
• Lithium Battery Cell - Two RC-Branch Equivalent Circuit
• Asynchronous PWM Voltage Source
• Discrete-Time PWM Voltage Source
11-7
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2012a
Version: 3.7
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2012a
Modeling Delays in Simscape Language
The new delay construct in Simscape language lets you refer to past values of
expressions in the equations section of the Simscape file. For more information, see the
delay reference page, and the new demo, Variable Transport Delay.
New Blocks for Modeling Delays
The new Delays sublibrary of the Physical Signals library contains two blocks:
• PS Constant Delay block returns the input signal delayed by a specified time, which is
constant throughout the simulation. You specify the delay time as a block parameter.
• PS Variable Delay block delays the input signal by a variable time. You specify the
delay time and the input history as additional inputs.
Use these blocks to model idealized transport phenomena at system level.
1D and 2D Interpolation Available in Simscape Language
The new tablelookup function in Simscape language lets you interpolate expressions in
the equations section of the Simscape file. It computes an output value by interpolating
the input value against a set of data points in a one-dimensional or two-dimensional
table, and supports three interpolation and two extrapolation options. This functionality
is similar to that of the Simulink and Simscape Lookup Table blocks. It allows you to
incorporate table-driven modeling directly in your custom block, without the need of
connecting an external Lookup Table block to your model. For more information, see the
tablelookup reference page.
The PS Lookup Table (1D) and PS Lookup Table (2D) blocks in the Foundation library
now use the tablelookup function in the Simscape language. The block functionality
and user interface remain the same.
Input Filtering Usability Enhancements
In previous releases, input filtering was automatically turned on whenever you used an
explicit solver in a Simscape model. To turn off input filtering when using an explicit
solver, you had to supply first derivative of the input signal as an additional input signal
to the Simulink-PS Converter block. For models using other types of solvers, input
filtering was not available.
12-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Now input filtering is independent of the solver used in the model. You can control
whether you filter input or provide time derivatives for each input signal individually, by
configuring the Simulink-PS Converter block connected to that input signal. You can:
• Set the Filtering and derivatives parameter to Filter input, and select whether
you want to use the first-order or second-order filter. Input filtering makes the input
signal smoother and generally improves model performance. The additional benefit
is that the Simscape engine computes the time derivatives of the filtered input. The
first-order filter provides one derivative, while the second-order filter provides the
first and second derivatives. If you use input filtering, it is very important to select
the appropriate value for the filter time constant.
• Set the Filtering and derivatives parameter to Provide input derivative(s),
and provide either just the first time derivative, or the first and the second time
derivatives, through additional input ports on the Simulink-PS Converter block.
By default, input signals are used as is, without performing input filtering or otherwise
providing time derivatives of the input signal. If you use an explicit solver, MathWorks
recommends that you provide input derivatives by selecting one of the options listed
above. If you do not provide input derivatives, and the solver you use requires them, you
get an error message indicating how many input derivatives you need to provide. For
more information, see Harmonizing Simulink and Simscape Solvers and the Simulink-PS
Converter block reference page.
Compatibility Considerations
Input filtering is no longer automatically turned on for models using explicit solvers.
Therefore if you have an existing model that uses an explicit solver, its performance and
simulation results may be different from the previous version.
Because Simscape solver no longer automatically provides the required input derivatives,
you may get an error message indicating how many input derivatives you need to
provide.
To preserve the old behavior, open each Simulink-PS Converter block and set the
Filtering and derivatives parameter to Filter input, while keeping the value of
the Input filtering time constant parameter unchanged. If any of the Simulink-PS
Converter blocks in your model had input derivatives provided as additional signals,
set the Filtering and derivatives parameter for such block to Provide input
derivative(s).
12-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2012a
Zero Damping Allowed for Resistive Elements
In previous releases, resistive blocks in the Foundation library required positive damping
coefficients. Negative damping values are nonphysical. However, zero damping values
are useful for model checking and testing, For example, if you use a Rotational Damper
block as part of a customized gear model, it is convenient to be able to set the Damping
coefficient parameter to 0 temporarily, to compute undamped responses.
The following blocks now allow zero damping values, to support model testing:
• Resistor (Electrical Elements library)
• Linear Hydraulic Resistance (Hydraulic Elements library)
• Rotational Damper (Rotational Elements library)
• Translational Damper (Translational Elements library)
Changes to Simscape Demos
The following demo has been added in Version 3.7:
Demo Name
Description
Variable Transport Delay
(ssc_transport_delay)
Provides an example of modeling a variable
transport delay using Simscape language.
The Transport Delay subsystem models signal
propagation through media moving between
the Input and the Output terminals. The
media velocity may vary, thus it is specified
through the block port. The distance between
the terminals is constant and it is specified as
a block parameter. To see the implementation
details, look under mask of the Transport
Delay subsystem, then right-click the Variable
Transport Delay block and select View
Simscape source.
12-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2011b
Version: 3.6
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2011b
Simscape Language Enables User-Defined Diagnostics During Simulation
The new assert construct in Simscape language lets you implement run-time error
messages when the custom block is used in a model. In the component file, you specify
the condition to be evaluated, as well as the error message to be output if this condition
is violated. When the custom block based on this file is used in a model, it will output
this error if the condition is violated during simulation. For more information, see
Programming Run-Time Errors and Warnings.
Compatibility Considerations
Run-time error checking has now been implemented in Foundation library, and may
affect the behavior of your existing models. For example, in previous releases, sqrt(x) for
negative numbers was calculated as | x|i sign ( x ) (e.g., sqrt(–1) = –1). Now it will give a
run-time error if the input becomes negative.
Run-time error checks have been implemented for the following functions:
Function
Condition
sqrt()
<0
log()
<= 0
log10()
<= 0
1/
== 0, if is an expression involving only constants and
parameters
The following Foundation library blocks are affected:
• PS Math Function block — when the inputs of log, log10, sqrt, and 1/u violate the
conditions listed above, the block will now generate a run-time error.
• PS Divide block — when the denominator is zero, the block will now generate a runtime error.
Existing models using these blocks, which ran successfully in previous releases due to
lack of error checking, will now generate a run-time error if one of the above conditions is
violated.
13-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
New Block for Modeling Discrete Delays
The Asynchronous Sample & Hold block, in the new Discrete sublibrary of the Physical
Signals library, sets output Y equal to input U when the rising edge of the trigger input
becomes greater than zero. Use this block, in conjunction with other physical signal
blocks, to model discrete and event-based behaviors.
Specialized Simulator for Linear Systems
The new specialized simulator, implemented for linear systems, reduces number of states
and accelerates simulation. The specialized linear simulator is automatically employed
based on the system structure, you do not have to select or enable it explicitly.
Rebuilding of Custom Block Libraries Now Required
Due to further scalability improvements, as well as other internal enhancement to
facilitate add-on product functionality, you have to rebuild your custom block libraries
once you upgrade to Version 3.6 (R2011b). It is required that you rebuild your custom
block libraries for use with each new version of Simscape software. For more information,
see When to Rebuild the Custom Library.
To rebuild the libraries, run ssc_build on the component Simscape files. If you try to
use the custom blocks without rebuilding the libraries, you will get an error message.
Running ssc_clean before ssc_build is strongly recommended but not required. If
you run into errors after running ssc_build, run ssc_clean and then try running
ssc_build again.
13-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2011a
Version: 3.5
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2011a
Additional Hydraulic Sources
Two new blocks have been added to the Hydraulic Sources library:
• Hydraulic Constant Flow Rate Source block represents an ideal source of hydraulic
energy that is powerful enough to maintain specified flow rate at its outlet regardless
of the pressure differential across the source. The Source flow rate parameter
specifies the flow rate through the source.
• Hydraulic Constant Pressure Source block represents an ideal source of hydraulic
energy that is powerful enough to maintain the specified pressure differential
between its inlet and outlet regardless of the flow rate through the source. The
Pressure parameter specifies the pressure differential across the source.
Use these blocks for models where flow rate or pressure remain constant throughout
simulation.
Improved Simulation Diagnostics
The following improvements in simulation diagnostics have been implemented, to aid
debugging:
• Equation dependency diagnostics now point to the specific equations (with line
number and file location info) within the component Simscape files.
• Equation dependency diagnostics have been extended to include switched-linear and
nonlinear equations in the analysis.
• Equation dependency diagnostics are now triggered on nonlinear solver failures that
occur after the start of simulation.
• Zero-crossing related warnings and error messages now point to the specific equations
(with line number and file location info) within the component Simscape files.
Improved Scalability
Various scalability improvements have been implemented in this release, accelerating
simulation of larger systems.
Compatibility Considerations
Due to this change, you have to rebuild your custom block libraries once you upgrade
to Version 3.5 (R2011a). To rebuild the libraries, run ssc_build on the component
14-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Simscape files. If you try to use the custom blocks without rebuilding the libraries, you
will get an error message.
Running ssc_clean before ssc_build is strongly recommended but not required. If
you run into errors after running ssc_build, run ssc_clean and then try running
ssc_build again.
Improved Algorithms for Algebraic Loop Detection and Zero-Crossing
Robustness
The following simulation algorithm improvements have been implemented in this
release:
• False algebraic loop detection and prevention—The improved algorithm can now
recognize false algebraic loops and prevent them from affecting simulation results.
• Performance and zero-crossing robustness improvements—Zero-crossing detection
algorithm has been optimized to ignore zero-crossings that do not result in model
behavior changes during simulation.
Change in Evaluating Unit Expressions
In the Unit Manager parser, multiplication (*) used to mistakenly have higher
precedence than division (/). This issue is now fixed. When evaluating unit expressions,
* and / now have the same precedence and are evaluated based on left associativity.
Compatibility Considerations
Due to this change, custom units specified in the unit registry may now evaluate
differently. For example, if you have added a unit m/s*s, in previous releases it was
evaluated as m/(s*s) = m/s^2. It will now evaluate to (m/s)*s = m. You can use
parentheses to preserve the old behavior.
14-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2010b
Version: 3.4
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2010b
Simulation Data Logging Enhancements
The following data logging enhancements have been implemented in this version:
• plot and plotxy commands have been added. The plot command lets you
plot logged data against time, while the plotxy command plots two sets of
data against each other. Also, plot and plotxy methods are now available for
simscape.logging.Node and simscape.logging.Series objects. For more
information, see the respective reference pages.
• New configuration parameter, Decimation, lets you downsample logged data by
skipping time steps. For more information, see Data Logging Options in the Simscape
User's Guide.
• Simulation data is now logged according to the value specified for the Output
options parameter in the Data Import/Export pane of the Configuration
Parameters dialog box.
Compatibility Considerations
For models that do not use the default value of the Output options parameter in
the Data Import/Export pane of the Configuration Parameters dialog box, logged
simulation data may change compared to the previous release.
Zero-Crossing Handling Enhancements
The creation and detection of zero-crossing conditions in Simscape models have been
improved.
New Implementation of Relational Functions Without Creating Simulink Zero-Crossing
Conditions
The Simscape language now implements relational functions in a different way from
how relational operators are implemented. Unlike relational operators, these relational
functions now do not create Simulink zero-crossing conditions.
For more information about zero crossings in Simscape models, see Creating and
Detecting Zero Crossings in Simscape Models in the Simscape User's Guide.
For more information about creating models in the Simscape language, see the Simscape
Language Guide and the equations syntax.
15-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Improved Zero-Crossing Detection Diagnostics
If your model generates a Simulink warning or error about zero crossings involving
Simscape blocks, the warning or error message now specifies which blocks are generating
this zero-crossing diagnostic message.
If you globally disable zero-crossing detection in a Simulink model containing Simscape
blocks, and if you are using a variable-step solver without a local solver, you now receive
a diagnostic warning or error. You can control which message that you receive in the
Simscape pane of the model Configuration Parameters dialog box, through the Zerocrossing control is globally disabled in Simulink drop-down list. This option
supports context-sensitive or “What's This?” help, by default accessed through rightclicking the item.
See Harmonizing Simulink and Simscape Solvers in the Simscape User's Guide.
C++ Code Generation Support
You can now generate C++ code from Simscape models. Encapsulated C++ code
generation is not supported.
For more information, see Code Generation and Limitations in the Simscape User's
Guide.
Sparse Solver Enhancement
The implementation and control of matrix linear algebra in the Solver Configuration
block have been improved and simplified. Whether you choose the sparse solver or the
full solver, your linear algebra choice is now implemented in both model simulation and
code generated from the model.
For more information, see the Solver Configuration block reference page.
Component Descriptor Is No Longer Inherited from the Base Class
In Simscape Language, the name of the block built from a component file generally
corresponds to the component file name. You can provide a more descriptive name for the
block by adding a comment line immediately following the component declaration. This
comment line is called the descriptor. For more information, see How to Customize the
Block Name.
15-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2010b
If you use subclassing, the subclass inherits all of the members (parameters, variables,
nodes, inputs and outputs) from the base class (for more information, see Subclassing
and Inheritance). In previous releases, descriptor was one of the inherited properties.
That is, if you had a subclass component without a descriptor, the resulting block name
was derived from the descriptor of the base class, instead of the component file name.
This could create issues with library building if both the subclass component and the
base class component were in the same sublibrary.
Starting with this release, descriptor is no longer inherited from the base class. In other
words, if a component file does not contain a comment line immediately following the
component declaration, the component name is always used for the block name.
Compatibility Considerations
For existing subclass components, if the component does not have a descriptor line, upon
rebuilding the library the block name will change compared to the previous release. To
preserve the old name, add a descriptor line to the subclass component file.
Documentation Enhancements
The Model Simulation chapter has been expanded and improved with revised and new
sections, including:
• How Simscape Models Represent Physical Systems
• How Simscape Simulation Works
• Setting Up Solvers for Physical Models
• Customizing Solvers for Physical Models
• Real-Time Simulation
• Finding an Operating Point
• Linearizing at an Operating Point
• Finding and Using Operating Points in an Electronic Circuit
Changes to Simscape Demos
The following demo has been added in Version 3.4:
Demo Name
15-4
Description
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Electrical Transformer
(ssc_transformer)
Presents a view inside a transformer core using
the electromagnetic blocks from the Magnetic
block library.
15-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2010a
Version: 3.3
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2010a
Magnetic Blocks Added to Foundation Library
Foundation library now contains magnetic domain and Magnetic block library.
This library contains electromagnetic elements, such as reluctances, actuators, and
electromagnetic converters, as well as magnetic sensors and sources.
Use these blocks to model magnetic circuits that can be represented by a one-dimensional
flux flow, for example, solenoids and transformers.
Magnetic block models are based on the following assumptions:
• The magnetic system is assumed lossless. You can model losses in interconnecting
systems instead – in electric systems using resistors and in mechanical systems using
friction.
• Modeling of superconductors (with zero relative permeability) is not supported.
For more information see the block reference pages. See also Magnetic Domain for
information on the magnetic domain definition. The Across variable is magnetomotive
force (mmf), and the Through variable is flux. Note that these result in a pseudo-bond
graph, because the product of mmf and flux is energy, not power.
Simulation Data Logging Now Available
You can now log simulation data to workspace for debugging and verification purposes.
Data logging lets you analyze how internal block variables change with time during
simulation. For example, you may want to see that the pressure in a hydraulic cylinder
is above some minimum value, or compare it against the pump pressure. If you log
simulation data to workspace, you can later query, plot, and analyze it without rerunning
the simulation. For more information, see Data Logging in the Simscape User's Guide.
Simscape Diagnostics Improvements
Simscape error messages triggered by initial dynamic state inconsistencies and by
nonlinear solver convergence failures are now more detailed. These messages report
specific components of your models that may have caused the error.
Sparse Jacobian Support
You can now use a Jacobian method with an implicit Simulink solver in your Simscape
models. You can choose a method yourself or allow Simulink to determine an appropriate
16-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Jacobian method for you. Depending on the sparsity pattern and number of states of your
model, your simulation may be more efficient.
See Choosing a Jacobian Method for an Implicit Solver in the Simulink documentation.
Ability to Generate Simscape Language Equations from Symbolic
Expressions
If you have Symbolic Math Toolbox™ software, you can use the simscapeEquation
function to generate Simscape language equations from symbolic expressions. For
more information, see Generating Simscape Equations in the Symbolic Math Toolbox
documentation.
Placing Simscape Blocks in Nonvirtual Subsystems
Nonvirtual subsystems that support continuous states include Enabled subsystems
and Atomic subsystems. These subsystems can contain Simscape blocks. However,
physical connections and physical signals must not cross nonvirtual boundaries. For
more information, see Restricted Simulink Tools in the Simscape User's Guide.
Compatibility Considerations
Simscape solver no longer permits physical connections and physical signals to cross
nonvirtual subsystem boundaries, because the semantics of these types of connections
are unclear. If either a physical signal or a physical connection crosses a nonvirtual
boundary, the solver issues an error upon simulation. To resolve the issue, place all
blocks belonging to a given Physical Network in the same nonvirtual subsystem.
Trimming and Linearization Documentation Enhancements
The documentation on Simscape model trimming and linearization has been revised and
expanded. See Finding an Operating Point and Linearizing at an Operating Point.
Changes to Simscape Demos
The following demos have been added in Version 3.3:
Demo Name
Description
16-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2010a
Circuit Breaker
(ssc_circuitbreaker)
Implements a simple circuit breaker model.
Solenoid with Magnetic Blocks
(ssc_solenoid_magnetic)
Shows how to model a solenoid using the
electromagnetic blocks from the new Magnetic
block library.
16-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2009b
Version: 3.2
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2009b
Pneumatic Blocks Added to Foundation Library
Foundation library now contains pneumatic domain and Pneumatic block library.
This library contains pneumatic elements, such as orifices, chambers, and pneumaticmechanical converters, as well as pneumatic sensors and sources.
Use these blocks to model pneumatic systems, for applications such as:
• Factory automation — basic pneumatic linear/rotational actuators, valves (variable
orifices), and air supply
• Robotics — robotic arms and haptic interfaces
• Gaseous transportation systems and pipelines
You can also use these blocks to model dry air and low pressure flows, for example, for
HVAC applications.
Pneumatic block models are based on the following assumptions:
• Working fluid is an ideal gas satisfying the ideal gas law.
• Specific heats at constant pressure and constant volume, and , are constant.
• Processes are adiabatic, that is, there is no heat transfer between components and the
environment (except for components with a separate thermal port).
• Gravitational effects are neglected.
For more information see the block reference pages, as well as Modeling Pneumatic
Systems in the Simscape User's Guide.
Compatibility Considerations
To avoid duplicate block names in different Simscape domains and increase naming
consistency across domains, the following hydraulic blocks have been renamed:
17-2
Old Block Name
New Block Name
Constant Area Orifice
Constant Area Hydraulic Orifice
Constant Volume Chamber
Constant Volume Hydraulic Chamber
Piston Chamber
Hydraulic Piston Chamber
Resistive Tube
Hydraulic Resistive Tube
Variable Area Orifice
Variable Area Hydraulic Orifice
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Old Block Name
New Block Name
Variable Chamber
Variable Hydraulic Chamber
Ideal Hydraulic Flow Rate Sensor
Hydraulic Flow Rate Sensor
Ideal Hydraulic Pressure Sensor
Hydraulic Pressure Sensor
Ideal Hydraulic Flow Rate Source
Hydraulic Flow Rate Source
Ideal Hydraulic Pressure Source
Hydraulic Pressure Source
Old models containing any of these blocks will be updated automatically once you open
and save them.
New and Enhanced Switches
The following switching capability enhancements have been implemented in Foundation
libraries:
• New Physical Signal PS Switch block has been added to the Nonlinear Operators
library. It contains three physical signal input ports, a physical signal output port,
and one parameter, Threshold. If the second input is greater than or equal to the
threshold, then the output is connected to the first input. Otherwise, the output is
connected to the third input. The second input never connects to the output.
• Electrical Switch block has been enhanced to use a value specified in the Threshold
parameter (rather than zero) for opening and closing the switch.
Intermediate Terms in Simscape Language Equations
You can now introduce intermediate terms in Simscape Language equations by using the
let and in keywords. This functionality helps increase the equation readability, as well
as avoid duplicating information by defining an intermediate term once and then using it
in multiple equations. For more information, see the Simscape Language Guide.
Local Solver Support in Physical Networks
The Solver Configuration block now lets you use sample-based local solver with a specific
sample time. In sample-based simulation, all the Physical Network states, otherwise
represented as continuous, become discrete states. The solver updates the states once per
time step. This option is especially useful for code generation, or hardware-in-the-loop
(HIL) simulations. For more information, see the Solver Configuration reference page.
17-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2009b
Simulink Manifest Tool Support
Dependency analysis tools for Simscape files have been added in this release. They
consist of the following command-line options:
• simscape.dependency.file — Perform dependency analysis for a single Simscape
file.
• simscape.dependency.lib — Perform dependency analysis for a Simscape custom
library.
• simscape.dependency.model — Perform dependency analysis on a model
containing Simscape and Simulink blocks.
Manifest reports generated using Simulink Manifest Tools now also include model
dependencies for the Simscape blocks. For more information, see Checking File and
Model Dependencies in the Simscape Language Guide.
SimState Support
Simscape software now supports Simulink SimState feature, introduced in R2009a. This
feature allows you to save all runtime data necessary for restoring the simulation state
of a model. For more information, see Saving and Restoring the Simulation State as the
SimState in the Simulink User's Guide.
Note When using SimState to save and restore simulations of models involving Simscape
blocks, please ensure both 'DstWorkSpace' and 'SrcWorkSpace' to be 'base' by
using:
simset('DstWorkspace', 'base', 'SrcWorkspace', 'base')
Model Reference Accelerator Mode Support
Simscape and its add-on products now fully support Model Reference Accelerator Mode,
both for model simulation and for code generation.
Physical Port Rotation for Simscape Blocks
When you rotate a regular Simulink block, its ports are by default reordered after
rotation, to maintain the left-right and top-down block diagram orientation convention
17-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
used in control system modeling applications. This convention is not applicable to
physical modeling and is potentially confusing, because it results in effectively rotating
and flipping the block at the same time.
Therefore, starting with Version 3.2 (R2009b), when you rotate a Simscape block
(including blocks from add-on products), its ports are not reordered. This behavior
is similar to that of the masked blocks with Port Rotation set to Physical. For
illustration of differences between the default port rotation type and the physical port
rotation type, see Changing a Block's Orientation in the Simulink User's Guide.
Compatibility Considerations
This change in the behavior of the ports after block rotation may result in visually
crossed connection lines in some of your existing block diagrams with rotated blocks. The
effect is purely cosmetic and has no impact on actual model connections or simulation.
17-5
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2009a
Version: 3.1
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2009a
Simscape Language Source Protection
Simscape language files can be protected to enable model sharing without disclosing the
component or domain source. You can then share the protected (executable) files without
disclosing the file content (similar to P-code vs M-code). While Simscape source files have
the extension .ssc, Simscape protected files have the extension .sscp.
Use the ssc_protect command to protect individual files and directories.
Use the ssc_mirror command to create a protected copy of a whole package, along with a
custom block library built from it.
For more information, see Using Source Protection for Simscape Files.
Expanded MATLAB Support of Simscape Files
MATLAB support of Simscape files has been expanded:
• If you issue the open command on a Simscape file, the file will open in the MATLAB
Editor. The Simscape file must be on the MATLAB path, or in a package residing in
a directory on the MATLAB path. For more information on packaging Simscape files,
see Organizing Your Simscape Files.
If you issue the open command on a Simscape protected file (*.sscp), the
corresponding Simscape source file (*.ssc) will open, provided it exists in the same
directory as the Simscape protected file.
• Issuing the help command on a Simscape file displays the domain or component
description, that is, all the comments immediately following the domain or component
declaration, in the MATLAB Command Window.
• MATLAB Editor now supports syntax highlighting of Simscape files, similar to Mfiles. For more information, see Adjust Editor Appearance.
Viewable and Customizable Source Files for Foundation Library Blocks
You can now view the source files for many Foundation library blocks. When you open
the block dialog box, it contains a link:
View source for BlockName
18-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Click this link to open the Simscape source file for this block in the MATLAB Editor.
To customize the block for your application, edit the source file and save it in a package
directory. For more information, see Simscape File Deployment.
Compatibility Considerations
The block source has been optimized, with some previously defined but unused variables
eliminated. Therefore, when you load an old model containing Foundation blocks, you
might get warnings, for example:
Warning: In instantiating linked block 'model/R1' : Resistor block (mask) does not
have a parameter named 'current_Log'.
You can safely ignore these warnings. Once you save the model, the warnings will
disappear.
Simscape Language Syntax Changes
The following changes have been implemented in Simscape language:
• The throughs keyword has been obsoleted. Use variables(Balancing=true) to
declare Through variables in a domain.
• The equation keyword has been changed to equations.
• The name of a Simscape file must match the name of the component or domain it
defines. If this is not the case, you will get an error when trying to build a library or
use the block in a model.
For more information, see the Simscape Language Guide.
Compatibility Considerations
The changes are relatively minor, but may require modifying your existing Simscape
files. The following table summarizes the old and new syntax.
Old Syntax
New Syntax
throughs
variables(Balancing=true)
equation
equations
18-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2009a
Increased Efficiency of Simscape Language Equations Processing
Simscape language equations are now processed more efficiently, reducing the time
required to process equations with multiple if statements.
New Physical Signal Blocks to Facilitate Rounding
Three new Physical Signal blocks have been added to the Nonlinear Operators library:
• PS Ceil block performs rounding of the signal toward positive infinity
• PS Floor block performs rounding of the signal toward negative infinity
• PS Fix block performs rounding of the signal toward zero
Model Reference Accelerator Mode Support
Simscape and its add-on products now support Model Reference Accelerator Mode for
model simulation, but not for code generation. Model Reference Accelerator Mode for code
generation is supported only by SimMechanics nd SimDriveline™ software.
Changes to Simscape Demos
The following demo has been added in Version 3.1:
Demo Name
Description
Creating A New Circuit
(ssc_new_elec)
Use this demo as a template for creating a new
electrical model. Open the demo and use File
> Save As to save it under the desired model
name. Then delete the unwanted components
and add new ones. This demo also opens an
Electrical Starter Palette, which contains links
to the most often used electrical components.
18-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2008b
Version: 3.0
New Features
Bug Fixes
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2008b
Simscape Language
New Simscape language extends the Simscape modeling environment by enabling you to
create new components that do not exist in the Foundation library or in any of the add-on
products. It is a dedicated textual physical systems modeling language with the following
characteristics:
• Derives from MATLAB and familiar to those who use MATLAB
• Contains additional constructs specific to physical modeling and excludes constructs
that have nothing to do with physical modeling
• Incorporated into the Simscape modeling interface
• Not focused on algorithm development
The Simscape language is intended to make modeling physical systems easy and
intuitive. It lets you create new physical domains and components as textual files and
then use them in Simscape block diagrams to model the desired physical effects. For
more information, see the Simscape Language Guide.
Explicit Solvers
It is now possible to choose any variable-step or fixed-step solver for models containing
Simscape blocks. Note, however, that implicit solvers, such as ode14x, ode23t, and
ode15s, are still a better choice for a typical model. In particular, for stiff systems,
implicit solvers typically take many fewer timesteps than explicit solvers, such as ode45,
ode113, and ode1.
By default, you will get a warning when using an explicit solver for a model containing
Simscape blocks. For models that are not stiff, however, explicit solvers can be effective,
often taking fewer timesteps than implicit solvers. Depending on the type of your model,
you can configure your preferences to either turn off this warning (if your model is not
stiff) or even change it into an error (to avoid inadvertent use of explicit solvers), by using
the Simscape pane of the Configuration Parameters dialog box.
If you use an explicit solver, it requires time derivatives of the input signals. By default,
needed input derivatives are provided by filtering the input through a low-pass filter.
The derivative of the filtered input can then be computed by the Physical Networks
simulation engine. The new Derivatives tab in the Simulink-PS Converter dialog box
lets you turn off input filtering and instead provide the first derivative of input as an
additional input signal to the Simulink-PS Converter block. For more information, see
the Simulink-PS Converter block reference page.
19-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Because input filtering can appreciably change the input signal and drastically affect
simulation results if the time constant is too large, a warning is issued when input
filtering is used. The warning indicates which Simulink-PS Converter blocks have their
input signals filtered. This warning can also be turned off (or changed to an error) by
changing the preferences on the Simscape pane of the Configuration Parameters dialog
box.
New Ways to Model Variable Chambers
There are now two blocks that let you model fluid compressibility in variable chambers:
• Piston Chamber block lets you model fluid compressibility in a chamber created by
the piston in a cylinder. It replaces the Variable Volume Chamber block, available in
previous releases.
• Variable Chamber block lets you model fluid compressibility in variable volume
chambers of any shape. The instantaneous value of the chamber volume is provided
by using a physical signal port.
Compatibility Considerations
The Variable Volume Chamber block, available in previous releases, has been
deprecated. It has been replaced by the Piston Chamber block in other (structural) blocks
and in demos shipped with the product. If you have used the Variable Volume Chamber
block in your models, it will continue to work. Going forward, however, use the Piston
Chamber block to model fluid compressibility in cylinder chambers.
Model Reference Support
Simscape software now supports the Simulink model referencing functionality in Normal
mode. Other Simulink models can now reference Simscape models in normal (non-codegeneration) execution. Simscape models continue to be able to reference Simulink models
(that do not contain Simscape blocks) in normal execution. See Limitations for more
details.
More Solver Performance and Robustness Enhancements
Version 3.0 contains multiple further enhancements to simulation algorithms, resulting
in improved robustness and reliability.
19-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2008a
Version: 2.1
New Features
Bug Fixes
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2008a
Trimming Now Available for Simscape Models
Finding and managing operating points by trimming has been implemented for models
that include Simscape and SimHydraulics blocks. Simulink Control Design™ product
is required for using this functionality. For more information, see Finding an Operating
Point in the Simscape documentation.
Thermal Unit Conversions Now Supported
You can now specify temperature for your thermal models in a variety of units, including
degrees Celsius, Fahrenheit, and Rankine. The unit manager automatically handles
conversions between thermal units.
Thermal units sometimes require an affine conversion, that is, a conversion that
performs both multiplication and addition. In situations when you deal with a relative,
rather than absolute, temperature, you need to convert using just the linear term.
Thermodynamic variables in block dialogs are automatically tagged as appropriate and
handled by the unit manager. However, when an input or output signal is related to
thermodynamic variables and contains units of temperature, you must decide whether
affine conversion needs to be applied. The Simulink-PS Converter and PS-Simulink
Converter block dialogs now contain the Apply affine conversion checkbox. If you
select it, the unit manager uses the affine conversion, otherwise it applies the default
linear conversion.
For more information, see Thermal Unit Conversions in the Simscape documentation, as
well as the Simulink-PS Converter and PS-Simulink Converter block reference pages.
The pm_addunit command has also been modified to support affine conversions. Its
second argument, conversion, may now be either a positive real scalar or a 1x2 array.
If this argument has two elements, then it is specifying an affine conversion, with the
first element (a positive real number) being the linear conversion coefficient, and the
second being the offset.
Enhancement to Specifying Units
Simscape block dialogs have drop-down combo boxes for units next to a parameter value.
You can either select a unit from the drop-down list, or type a commensurate unit name
(or a mathematical expression with unit names) directly into the units combo box of the
block dialog. For more information, see How to Specify Units in Block Dialog Boxes in the
Simscape documentation.
20-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
Similarly, the Simulink-PS Converter and PS-Simulink Converter block dialogs now
contain a drop-down list, which is prepopulated with some common input or output
units. You can either select a unit from the list or type a unit name, or a mathematical
expression with unit names. Note that you must still match the unit type:
• For a PS-Simulink Converter block, these units must be commensurate with the units
of the input physical signal coming into the block.
• Signal units that you specify in a Simulink-PS Converter block must match the input
type expected by the Simscape block connected to it.
New Blocks
Version 2.1 contains two new blocks:
• Gyrator block in the Electrical Elements library simulates an ideal gyrator, which can
be used to implement an inductor with a capacitor.
• PS Abs block in the Physical Signals library returns absolute value of input signal.
Enhancements to Simulation Algorithms
Version 2.1 contains multiple enhancements to simulation algorithms, resulting in
improved robustness and reliability.
“What’s This?” Context-Sensitive Help Available for Simulink
Configuration Parameters Dialog
R2008a introduces “What's This?” context-sensitive help for parameters that appear in
the Simulink Configuration Parameters dialog, including those on the Simscape pane.
This feature provides quick access to a detailed description of the parameters, saving you
the time it would take to find the information in the Help Browser.
To use the "What's This?" help, do the following:
1
Place your cursor over the label of a parameter.
2
Right-click. A What's This? context menu appears.
For example, the following figure shows the What's This? context menu appearing
after a right-click on the Start time parameter in the Solver pane.
20-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2008a
3
Click What's This?. A context-sensitive help window appears showing a description
of the parameter.
New Simscape Demo
The following demo has been added in Version 2.1:
Demo Name
Description
House Heating System
(ssc_house_heating_system)
The demo represents a simple house heating
system consisting of a heater, thermostat,
and a house structure with four thermally
distinguishable parts: inside air, house walls,
windows, and roof. You can investigate system
behavior with the heating system turned on
or off, and plot the heat cost and indoor versus
outdoor temperatures.
20-4
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2007b
Version: 2.0
New Features
Bug Fixes
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2007b
Code Generation Now Available for Simscape Models
Code generation has been implemented for models that include Simscape and
SimHydraulics blocks. For more information, see Code Generation in the Simscape
documentation.
New Thermal Block Libraries
Version 2.0 contains new block libraries of fundamental thermal elements, sensors, and
sources:
• Conductive Heat Transfer
• Convective Heat Transfer
• Radiative Heat Transfer
• Thermal Mass
• Thermal Reference
• Ideal Heat Flow Source
• Ideal Heat Flow Sensor
• Ideal Temperature Source
• Ideal Temperature Sensor
Additional Physical Signal Blocks
The new Physical Signal blocks introduced in Version 2.0 are listed below:
• PS Constant
• PS Math Function
• PS Max
• PS Min
• PS Sign
Improved Simulation Performance
In Version 2.0, various solver improvements have led to improved simulation
performance:
21-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
• Enhanced handling of dependent dynamic states (higher-index DAEs)
Simscape can now handle dependencies among the dynamic states as long as they are
linear in the states and independent of time and inputs. This allows you, for example,
to connect capacitors in parallel (even with their parasitic series resistances set to 0),
inductors in series, and so on.
• Significant reduction of the number of equations, which substantially increased
simulation speed
The typical speedup of your models is between 5 and 10 times. There are some
models that are below and above this range. Also, the number of states and equations
changed between releases. This means that you will have to reset any calculations
that relied on the states (such as initial state setting).
The changes to the simulation technology are significant. You may find that some of your
models may require different or tighter tolerances to converge, while others will require
no change. Refer to the troubleshooting section in the User's Guide for help in finding the
cause of a problem if simulation failed.
New Simscape Demos
The following demos have been added in Version 2.0:
Demo Name
Description
DC Motor Thermal Circuit
(ssc_dc_motor_thermal_circuit)
The demo illustrates how the thermal behavior
of a motor can be simulated in lumped
parameters.
Round Rod Heat Conduction
(ssc_round_rod_heat_conduction)
The demo illustrates the usage of thermal blocks
for developing a model of a long iron rod that
is heated with a heat source through its left
face. The right face and the outer cylindrical
surface are open to atmosphere, with a force
heat convection.
21-3
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2007a
Version: 1.0
New Features
Compatibility Considerations
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
R2007a
Product Introduction
Simscape software extends the Simulink product line with tools for modeling and
simulating multidomain physical systems. It enables you to describe multidomain
physical systems containing mechanical, hydraulic, and electrical components as physical
networks.
Simscape key features are:
• Single modeling environment for modeling and simulating physical systems, such as
mechanical, electrical, and hydraulic systems
• Foundation library of physical modeling building blocks and fundamental
mathematical elements
• Connection blocks to bridge modeling domains
• Full simulation and limited editing capabilities for models built with SimMechanics,
SimDriveline, or SimHydraulics blocks (no license for these products required as long
as the products are installed)
• Ability to specify units of parameters and variables, with all unit conversion handled
automatically
Simscape software can be used for a variety of automotive, aerospace, defense, and
industrial equipment applications. Together with SimMechanics, SimDriveline,
SimHydraulics, and SimPowerSystems™ (all available separately), Simscape lets you
model complex interactions in electromechanical and hydromechanical systems.
Block Libraries Moved from SimHydraulics to Simscape
The Foundation and Utilities block libraries that used to be included in SimHydraulics
( V1.0 and V1.1) are now part of Simscape product.
Compatibility Considerations
Several blocks that used to be in SimHydraulics V1.1 and are now part of Simscape
software have undergone changes that have compatibility impact. These blocks are:
• Fluid Inertia
• Inertia
• Mass
22-2
Confidential Prerelease Documentation — Subject to Nondisclosure Agreement
Foundation Library and Simulation
• PS Integrator
• Rotational Spring
• Translational Spring
Each of these blocks has a parameter that specifies the initial condition for use in
computing the block's initial state at the beginning of a simulation run. In this version,
there is a difference in the way these initial conditions are computed, and as a result,
the blocks work differently than they used to in the previous version. For details, see the
block reference pages.
22-3