Universal transmitter 4116 – Input for RTD, TC, Ohm, potentiometer, mA and V – 2-wire supply > 16 V – FM-approved for installation in Div. 2 – Output for current, voltage and 2 relays – Universal AC or DC supply Advanced features • Programmable via detachable display front (4501), process calibration, signal and relay simulation, password protection, error diagnostics and selection of help text in several languages. Connections Application • Linearized, electronic temperature measurement with RTD or TC sensor. • Conversion of linear resistance variation to a standard analog current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer. • Power supply and signal isolator for 2-wire transmitters. • Process control with 2 pairs of potential-free relay contacts and analog output. • Galvanic separation of analog signals and measurement of floating signals. • The 4116 is designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations. Technical characteristics • When 4116 is used in combination with the 4501 display / programming front, all operational parameters can be modified to suit any application. As the 4116 is designed with electronic hardware switches, it is not necessary to open the device for setting of DIP-switches. • A green / red front LED indicates normal operation and malfunction. A yellow LED is ON for each active output relay. • Continuous check of vital stored data for safety reasons. • 4-port 2.3 kVAC galvanic isolation. This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability Environmental Conditions Operating temperature................................... Storage temperature...................................... Calibration temperature................................. Relative humidity............................................ Protection degree........................................... -20°C to +60°C -20°C to +85°C 20...28°C < 95% RH (non-cond.) IP20 Mechanical specifications Dimensions (HxWxD)..................................... Dimensions (HxWxD) w/ 4501 / 4511............................................................. Weight approx................................................ Weight incl. 4501 / 4511 (approx.)................. Wire size........................................................ Screw terminal torque.................................... Vibration......................................................... 2...13.2 Hz...................................................... 13.2...100 Hz.................................................. 109 x 23.5 x 104 mm 109 x 23.5 x 116 / 131 mm 170 g 185 g / 270 g 1 x 2.5 mm2 stranded wire 0.5 Nm IEC 60068-2-6 ±1 mm ±0.7 g Common specifications Supply Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC Max. required power...................................... ≤ 2.5 W Isolation voltage Isolation voltage, test / working........................................................... 2.3 kVAC / 250 VAC Response time Temperature input (0...90%, 100...10%)...................................................... ≤ 1 s mA / V input (0...90%, 100...10%).................. ≤ 400 ms Auxiliary supplies 2-w. supply (term. 44...43)............................. 25...16 VDC / 0...20 mA Fuse............................................................... 400 mA SB / 250 VAC Programming................................................. Communication enabler 4511 / Programming front 4501 Signal / noise ratio......................................... Min. 60 dB (0...100 kHz) Accuracy........................................................ Better than 0.1% of selected range EMC immunity influence................................ < ±0.5% of span Extended EMC immunity: NAMUR NE 21, A criterion, burst................................. < ±1% of span Input specifications RTD input RTD type........................................................ Pt10/20/50/100/200/250; Pt300/400/500/1000; Ni50/100/120/1000; Cu10/20/50/100 Cable resistance per wire (max.)............................................................. 50 Ω Sensor current............................................... Nom. 0.2 mA Effect of sensor cable resistance (3-/4-wire)....................................................... < 0.002 Ω / Ω Sensor error detection................................... Yes Short circuit detection.................................... < 15 Ω Linear resistance input Linear resistance min....max.......................... 0 Ω...10000 Ω TC input Current input Measurement range....................................... Programmable measurement ranges............ Input resistance.............................................. Sensor error detection: Loop break 4...20 mA.............................................. 0...20 mA 0...20 and 4...20 mA Nom. 20 Ω + PTC 50 Ω Yes Voltage input Measurement range....................................... 0...12 VDC Programmable measurement ranges............ 0/0.2...1, 0/1...5, 0/2...10 VDC Input resistance.............................................. Nom. 10 MΩ Output specifications Current output Signal range................................................... 0...20 mA Programmable signal ranges......................... 0...20 / 4...20 / 20...0 and 20...4 mA Load (@ current output)................................. ≤ 800 Ω Load stability.................................................. ≤ 0.01% of span / 100 Ω Sensor error indication................................... 0 / 3.5 / 23 mA / none NAMUR NE 43 Upscale/Downscale.............. 23 mA / 3.5 mA Output limitation, on 4...20 and 20...4 mA signals.................................... 3.8...20.5 mA Output limitation, on 0...20 and 20...0 mA signals.................................... 0...20.5 mA Current limit.................................................... ≤ 28 mA Voltage output Signal range................................................... 0...10 VDC Programmable signal ranges......................... 0/0.2...1; 0/1...5 ; 0/2...10; 1...0.2/0; 5...1/0; 10...2/0 V Load (@ voltage output)................................ ≥ 500 kΩ Relay output Relay functions.............................................. Setpoint, Window, Sensor error, Latch, Power and Off Max. voltage................................................... 250 VRMS Max. current................................................... 2 AAC or 1 ADC Max. AC power.............................................. 500 VA Observed authority requirements EMC............................................................... 2014/30/EU LVD................................................................ 2014/35/EU Approvals FM.................................................................. 3025177 UL................................................................... UL 508 EAC................................................................ TR-CU 020/2011 DNV-GL Marine............................................. Stand. f. Certific. No. 2.4 EU RO Mutual Recognition Type Approval......................................................... MRA000000Z SIL.................................................................. Hardware assessed for use in SIL applications 4116-020317 Potentiometer input Potentiometer min....max............................... 10 Ω...100 kΩ Thermocouple type........................................ B, E, J, K, L, N, R, S, T, U, W3, W5, LR Cold junction compensation (CJC) via ext. sensor in connector 5910.............................................. 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C CJC via internally mounted sensor............................................................ ±(2.0°C + 0.4°C * Δt) Δt =................................................................. Internal temperature-ambient temperature Sensor error detection................................... Yes Sensor error current: When detecting / else............................................... Nom. 2 μA / 0 μA
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement