Di-LOG DL9206 multimeter Operating manual
Below you will find brief information for multimeter DL9206. The DL9206 is an autoranging digital multimeter that is ideal for a wide range of applications. It features a wide range of measurement functions including DC and AC voltage, DC and AC current, resistance, capacitance, frequency, duty cycle, diode test, and continuity. The DL9206 is also equipped with a data hold function, auto power off, and a low battery indicator. This multimeter will be a valuable addition to your toolbox.
Advertisement
Advertisement
Warranty & Maintenance
DL9206
operating manual
AUTORANGING
MULTIMETER
Di-Log Test Equipment
28 Wheel Forge Way,
Trafford Park,
Manchester
M17 1EH, UK
tel: + 44 161 877 0322 fax: + 44 161 877 1614
email: [email protected] website: www.dilog.co.uk
EN
61010-1
CAT
III
Safety Information
This manual contains information that must be followed for operating the meter safely and maintaining the meter in a safe operating condition.
If this meter is not used in the manner specified, the protection provided may be impaired.
Warning! Warns of potential danger, refer to the instruction manual to avoid personal injury or damage to the meter.
Caution! Dangerous voltage. Danger of electrical shock.
Continuous double or reinforced insulation complies with IEC536, class II.
Symbol of conformity, confirms conformity with relevant EU directives. The meter complies with
EMC directives (89/336/EEC). Specifically standards EN 50081-1 and EN 50082-1 as well as the
Low Voltage Directive (73/23/EEC) described in the standard EN 61010-1.
Safety Information Safety Information
The meter has been designed in accordance with the safety regulations for electronic measuring instruments, EN 61010-1, IEC 61010.
Voltages above 75V DC or 50V AC may constitute a serious shock hazard.
Before using the meter check for physical damage to the casing in particular around the connectors. If the case is damaged do not use the meter.
Check the test leads for damaged insulation or exposed metal. Check the leads for continuity.
Replace damaged leads with identical model or specification before using the meter.
Where applicable use GS38 approved leads (not supplied) these are available from Di-Log. When using test leads keep fingers behind the finger guards.
Do not apply more than the rated voltage, as marked on the meter between the terminals or between any terminal and ground.
Safety Information
Before making a measurement ensure that the rotary switch is set to the appropriate range. Do not turn the rotary switch whilst making a measurement.
Use the appropriate terminals, function and range for your measurements. If the value to be measured is not known use the maximum measurement position and reduce the range step by step until a satisfactory reading is obtained.
Do not use or store the meter in an environment of high temperature, humidity, fumes, vapour, gaseous, inflammable and strong magnetic field. The performance and safety of the use may be compromised in such circumstances.
Disconnect circuit power and discharge all high voltage capacitors before testing resistance, continuity, diodes, capacitance or current.
Before measuring current check the meters fuses and turn off power to the circuit before connecting the meter to the circuit.
Safety Information Safety Information
Replace the battery as soon as the low battery indicator appears. If the battery is low the meter may give false readings.
Turn the meter power off when not in use,. Remove the battery if the meter is in use for a long period.
Constantly check the battery as it may have leaked.
A leaking battery will damage the meter.
The meter may only be opened by a qualified service technician for calibration and repair.
Input Limits
Never apply voltage or current to the meter that exceeds the specified maximum:
Function Maximum
V DC or V AC
A DC/AC
Frequency, Resistance,
Capacitance, Duty Cycle,
Diode test, Continuity
Temperature
1000V DC, 750V AC
10A DC/AC
(30 seconds max every 15 minutes)
250V DC/AC
250V DC/AC
Symbols and Annunciators
BAT
Continuity
Low Battery
HOLD
AUTO
AC
DC
Diode
Data Hold
AutoRanging
Alternating Current or Voltage
Direct Current or Voltage
Input Limits Controls and Inputs
1
6
7
8
9
2
3
5
4
1
.
6000 count Liquid Crystal Display with symbolic signs.
2. Function rotary switch.
3. 10A (positive) input terminal for 10A DC or AC measurements.
4. COM (negative) input terminal.
5. Positive input terminal.
6. HOLD pushbutton.
7. Max/Min pushbutton.
8. Range/ Diode pushbutton.
9. Hz/Duty pushbutton.
Specifications
The instrument complies with: EN61010-1.
Insulation: Class2, Double insulation.
Overvoltage category: CATIII 600V.
Display:
6000 counts LCD display with function indication.
Polarity: Automatic, (-) negative polarity indication.
Overrange: “OL” mark indication.
Low battery indication: The “BAT” is displayed when the battery voltage drops below the operating level.
Measurement rate: 2 times per second, nominal.
Auto power off: Meter automatically shuts down after approx. 15 minutes of inactivity.
Operating environment: 0˚C to 50˚C (32˚F to 122
˚F) at < 70 % relative humidity.
Storage temperature: -20˚C to 60˚C (-4˚F to 140˚F) at < 80 % relative humidity.
For inside use, max height: 2000m
Pollution degree: 2
Power: One 9V battery , NEDA 1604, IEC 6F22.
Dimensions: 150 (H) x 70 (W) x 48 (D) mm
Weight: Approx.: 255g.
Accuracy is given at 18˚C to 28˚C (65˚F to 83˚F), less than 70 % RH
Specifications Specifications
DC Voltage
Range
600.0mV
6.000V
60.00V
600.0V
Resolution
0.1mV
1mV
10mV
100mV
Accuracy
±0.5% of rdg + 2 dgts
±1.2% of rdg + 2 dgts
1000V 1V ±1.5% of rdg + 2 dgts
Input Impedance: 7.8MΩ.
Maximum Input: 1000V dc or 750V ac rms.
AC Voltage
Range
6.000V
60.00V
600.0V
Resolution
1mV
10mV
100mV
750V 1V
Input Impedance: 7.8MΩ.
Accuracy
+1.2% of rdg + 3 dgts
+1.5% of rdg + 3 dgts
+2.0% of rdg + 4 dgts
Frequency Range: 50 to 60Hz .
Maximum Input: 1000V dc or 750V ac rms..
DC Current
(Auto-ranging for uA and mA)
Range
10A
Resolution
1mA
Accuracy
±2.5% of rdg + 5 dgts
Overload Protection: 10A / 250V Fuse.
Maximum Input: 10A dc or ac rms on 10A DC range..
AC Current
(Auto-ranging for uA and mA)
Range
10A
Resolution
1mA
Accuracy
±3.0% of rdg + 7 dgts
Overload Protection: 10A / 250V Fuse.
Frequency Range: 50 to 60 Hz.
Maximum Input: 10A dc or ac rms on 10A AC range.
Specifications
Resistance
(Auto-ranging)
Range
600.0Ω
6.000kΩ
60.00kΩ
600.0kΩ
6.000MΩ
60.00MΩ
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
Accuracy
±1.2% of rdg + 4 dgts
±1.0% of rdg + 2 dgts
±1.2% of rdg + 2 dgts
±2.0% of rdg + 3 dgts
Input Protection: 250V dc or 250V ac rms.
Capacitance
(Auto-ranging)
Range
40.00nF
400.0nF
4.000uF
40.00uF
400.0uF
4000uF
Resolution
10pF
0.1nF
1nF
10nF
0.1uF
1uF
Accuracy
±5.0% of rdg + 7 dgts
±3.0% of rdg + 5 dgts
±5.0% of rdg + 5 dgts
±5.0% of rdg + 5 dgts
Input Protection: 250V dc or 250V ac rms.
Frequency
(Auto-ranging)
Range
6.999Hz
69.99Hz
699.9Hz
6.999kHz
69.99kHz
699.9kHz
2.999MHz
Resolution
0.001Hz
0.01Hz
0.1Hz
1Hz
10Hz
100Hz
1kHz
Sensitivity: >0.5V RMS while ≤ 1MHz ;
Sensitivity: >3V RMS while >1MHz ;
Accuracy
±1.5% of rdg + 5 dgts
±1.2% of rdg + 3 dgts
±1.5% of rdg + 4 dgts
Overload protection: 250V dc or ac rms.
Specifications Specifications
Duty Cycle
Range
0.1%~99.9%
Resolution
0.1%
Accuracy
±1.2% of rdg + 2 dgts
Pulse width: >100us, <100ms; Frequency width: 5Hz – 150kHz
Sensitivity: >0.5V RMS Overload protection: 250V dc or ac rms.
Temperature
Range Resolution
-20˚C~+760˚C 1˚C
-4˚F~+1400˚F 1˚F
Sensor: Type K Thermocouple.
Overload protection: 250V dc or ac rms.
Accuracy
±3% of rdg
±5˚C/9˚F
Diode Test
Range
0.3mA typical
Resolution
1 mV
Open circuit voltage: 1.5V dc typical.
Overload protection: 250V dc or ac rms.
Accuracy
±10% of rdg + 5 dgts
Audible continuity
Audible threshold: Less than 30Ω;
Test current: <0.3mA
Overload protection: 250V dc or ac rms.
Operation
Warning:
RISK OF ELECTROCUTION. HIGH-VOLTAGE CIRCUITS,
BOTH AC AND DC, ARE VERY DANGEROUS AND
SHOULD BE MEASURED WITH GREAT CARE.
1. ALWAYS turn the function switch to the OFF position when the meter is not in use. This meter has Auto OFF that automatically shuts the meter
OFF if 15 minutes elapse between uses.
2. If “OL” appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range.
Note:
On some low AC and DC voltage ranges, with the test leads not connected to a device, the display may show a random, changing reading. This is normal and is caused by the high-input sensitivity.
The reading will stabilize and give a proper measurement when connected to a circuit.
Operation Operation
Range Button
When the meter is first turned on, it automatically goes into AutoRanging. This automatically selects the best range for the measurements being made and is generally the best mode for most measurements.
For measurement situations requiring that a range be manually selected, perform the following:
1. Press the RANGE button. The “AUTO” display indicator will turn off.
2. Press the RANGE button to step through the available ranges until you select the range you want.
3. Press and hold the RANGE button for 2 seconds to exit the Manual Ranging mode and return to
AutoRanging.(If backlight is turn on, please press BACKLIGHT button it will turn off).
4. To select Diode/continuity.
Data Hold Button
The Hold function allows the meter to “freeze” a measurement for later reference.
1. Press the HOLD button to “freeze” the reading on the indicator. The indicator “HOLD” will be appear in the display.
2. Press the HOLD button to return to normal operation.
Operation
Hz/duty
1. Switch to Hz/Duty range.
2. Press the Hz/Duty button to show the reading in the display and the “Hz/Duty” indicator will appear on the display.
Operation DC Voltage Measurements
Caution:
DO NOT MEASURE DC VOLTAGES IF A MOTOR ON
THE CIRCUIT IS BEING SWITCHED ON OR OFF.
LARGE VOLTAGE SURGES MAY OCCUR THAT
CAN DAMAGE THE METER.
1. Set the function switch to the V DC position .
2. Insert the black test lead banana plug into the negative (COM) terminal and the red test lead banana plug into the positive (V) terminal.
3. Connect the test probe tips to the circuit under test. Be sure to observe the correct polarity (red lead to positive, black lead to negative).
4. Read the voltage in the display. The display will indicate the proper decimal point and value. If the polarity is reversed, the display will show (-) minus before the value.
AC Voltage Measurements
Warning:
RISK OF ELECTROCUTION. THE PROBE TIPS MAY NOT
BE LONG ENOUGH TO CONTACT THE LIVE PARTS IN-
SIDE SOME 240V OUTLETS FOR APPLIANCES BECAUSE
THE CONTACTS ARE RECESSED DEEP IN THE OUTLETS.
AS A RESULT, THE READING MAY SHOW 0 VOLTS WHEN
THE OUTLET ACTUALLY HAS VOLTAGE ON IT. MAKE
SURE THE PROBE TIPS ARE TOUCHING THE METAL
CONTACTS INSIDE THE OUTLET BEFORE ASSUMING
THAT NO VOLTAGE IS PRESENT.
Caution:
DO NOT MEASURE AC VOLTAGES IF A MOTOR ON
THE CIRCUIT IS BEING SWITCHED ON OR OFF.
LARGE VOLTAGE SURGES MAY OCCUR THAT CAN
DAMAGE THE METER.
1. Set the function switch to the V AC position.
2. Insert the black test lead banana plug into the negative (COM) terminal and the red test lead banana plug into the positive (V) terminal.
3. Connect the test probe tips to the circuit under test.
4. Read the voltage in the display. The display will indicate the proper decimal point, value and symbol (AC, V, etc.).
AC Voltage Measurements DC Current Measurements
Caution:
DO NOT MAKE CURRENT MEASUREMENTS ON
THE 10A SCALE FOR LONGER THAN 30 SECONDS.
EXCEEDING 30 SECONDS MAY CAUSE DAMAGE TO
THE METER AND/OR THE TEST LEADS.
1. Insert the black test lead banana plug into the negative (COM) terminal.
2. For DC current measurements , set the function switch to the DC 10A position and insert the red test lead banana plug into the 10A terminal.
3. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.
4. Connect the black test probe tip to the negative side of the circuit. Connect the red test probe tip to the positive side of the circuit.
5. Apply power to the circuit.
6. Read the current in the display. The display will indicate the proper decimal point, value and symbol.
AC Current Measurements
Warning:
TO AVOID ELECTRIC SHOCK, DO NOT MEASURE
AC CURRENT ON ANY CIRCUIT WHOSE VOLTAGE
EXCEEDS 250V AC.
Caution:
DO NOT MAKE CURRENT MEASUREMENTS ON THE 10A
SCALE FOR LONGER THAN 30 SECONDS. EXCEEDING 30
SECONDS MAY CAUSE DAMAGE TO THE METER AND/OR
THE TEST LEADS.
1. Insert the black test lead banana plug into the negative (COM) terminal.
2. For AC current measurements , set the function switch to the AC 10A position and insert the red test lead banana plug into the 10A terminal.
3. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.
4. Connect the black test probe tip to the negative side of the circuit. And connect the red test probe tip to the positive side of the circuit.
5. Apply power to the circuit.
6. Read the current in the display. The display will indicate the proper decimal point, value and symbol.
AC Current Measurements Resistance Measurements
Warning:
TO AVOID ELECTRIC SHOCK, DISCONNECT POWER
TO THE UNIT UNDER TEST AND DISCHARGE ALL
CAPACITORS BEFORE TAKING ANY RESISTANCE
MEASUREMENTS. REMOVE THE BATTERIES AND
UNPLUG THE LINE CORDS.
1. Set the function switch to the Ω position.
2. Insert the black test lead banana plug into the negative (COM) terminal and the red test lead banana plug into the positive Ω terminal.
3. Connect the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading.
4. Read the resistance in the display. The display will indicate the proper decimal point, value and symbol.
Continuity Check
Warning:
TO AVOID ELECTRIC SHOCK, NEVER MEASURE
CONTINUITY ON CIRCUITS OR WIRES THAT HAVE
VOLTAGE ON THEM.
1. Set the function switch to the position.
2. Insert the black lead banana plug into the negative
(-) terminal (COM) and the red test lead banana plug into the positive (+) terminal (Ω).
3. Press the button until the symbol appears in the display.
4. Connect the test probe tips to the circuit or wire you wish to check.
5. If the resistance is less than approximately 30Ω, the audible signal will sound. The display will also show the actual resistance.
Continuity Check Diode Test
Warning:
TO AVOID ELECTRIC SHOCK, DO NOT TEST ANY DIODE
THAT HAS VOLTAGE ON IT.
1. Set the function switch to position.
2. Press the button until the symbol appears in the display.
3. Insert the black test lead banana plug into the negative (-) terminal (COM) and the red test lead banana plug into the positive (+) terminal(Ω).
4. Connect the test probe tips to the diode or semiconductor junction you wish to test. Note the meter reading.
5. Reverse the probe polarity by switching probe position. Note this reading.
6. The diode or junction can be evaluated as follows:
A. If one reading shows a value and the other reading shows OL, the diode is good.
B. If both readings show OL, the device is open.
C. If both readings are very small or 0, the device is shorted.
Note:
The value indicated in the display during the diode check is the forward voltage.
Frequency Measurements
1. Set the function switch to the FREQ position.
2. Insert the black test lead banana plug into the negative (-) terminal (COM) and the red test lead banana plug into the positive (+) terminal (F).
3. Connect the test probe tips to the circuit under test.
4. Read the frequency in the display. The digital reading will indicate the proper decimal point, symbols (Hz, kHz) and value.
Frequency Measurements Capacitance Measurements
Warning:
TO AVOID ELECTRIC SHOCK, DISCONNECT POWER
TO THE UNIT UNDER TEST AND DISCHARGE ALL
CAPACITORS BEFORE TAKING ANY CAPACITANCE
MEASUREMENTS. REMOVE THE BATTERIES AND
UNPLUG THE LINE CORDS.
1. Set the function switch to the CAP position. (“nF” and a small value will appear in the display).
2. Insert the black test lead banana plug into the negative (-) terminal (COM) and the red test lead banana plug into the positive (+) terminal(CAP).
3. Connect the test leads to the capacitor to be tested.
The display will indicate the proper decimal point, value and symbol.
Temperature Measurement
Warning:
TO AVOID ELECTRIC SHOCK, DISCONNECT BOTH TEST
PROBES FROM ANY SOURCE OF VOLTAGE BEFORE
MAKING A TEMPERATURE MEASUREMENT.
1. If you wish to measure temperature in ˚F, set the function switch to the ˚F range. If you wish to measure temperature in ˚C, set the function switch to the ˚C range.
2. Insert the type K thermocouple probe black test lead banana plug into the negative COM terminal and the red test lead banana plug into the positive
Temp terminal.
3. Connect the Temperature Probe head to the part whose temperature you wish to measure. Keep the probe connected to the part under test until the reading stabilizes (about 30 seconds).
4. Read the temperature in the display. The digital reading will indicate the proper decimal point and value.
Warning:
TO AVOID ELECTRIC SHOCK, BE SURE THE
THERMOCOUPLE HAS BEEN REMOVED BEFORE
CHANGING TO ANOTHER MEASUREMENT FUNCTION.
Temperature Measurement Replacing the Battery
Warning:
TO AVOID ELECTRIC SHOCK, DISCONNECT THE TEST
LEADS FROM ANY SOURCE OF VOLTAGE BEFORE
REMOVING THE BATTERY COVER.
1. When the batteries become exhausted or drop below the operating voltage, “BAT” will appear in the right-hand side of the LCD display. The battery should be replaced.
2. Disconnect the test leads from the meter.
3. Open the battery cover by loosening the screw using a Phillips head screwdriver.
4. Insert the battery into battery holder, observing the correct polarity.
5. Put the battery cover back in place. Secure with the two screws.
6. Follow instructions for installing battery. See the
Battery Installation section of this manual.
Warning:
TO AVOID ELECTRIC SHOCK, DO NOT OPERATE THE
METER UNTIL THE BATTERY COVER IS IN PLACE AND
FASTENED SECURELY.
Note:
If your meter does not work properly, check the fuses and battery to make sure that they are still good and that they are properly inserted.
Replacing the Fuses
Warning:
TO AVOID ELECTRIC SHOCK, DISCONNECT THE TEST
LEADS FROM ANY SOURCE OF VOLTAGE BEFORE
REMOVING THE FUSE COVER.
1. Disconnect the test leads from the meter and any item under test.
2. Open the fuse cover by loosening the screw on the door using a Phillips head screwdriver.
3. Remove the old fuse from its holder by gently pulling it out.
4. Install the new fuse into the holder.
5. Always use a fuse of the proper size and value
(0.5A/250V fast blow for the 400mA range,
10A/250V fast blow for the 10A range).
6. Put the fuse cover back in place. Insert the screw and tighten it securely.
Warning:
TO AVOID ELECTRIC SHOCK, DO NOT OPERATE YOUR
METER UNTIL THE FUSE COVER IS IN PLACE AND
FASTENED SECURELY.
Replacing the Fuses Notes
Warranty & Maintenance
24 Month Warranty
Di-Log instruments are subject to stringent quality controls.
If in the course of normal daily use a fault occurs we will provide a 24 month warranty (only valid with invoice).
Faults in manufacture and materials defect will be rectified by us free of charge, provided the instrument has not been tampered with and returned to us unopened.
Damage due to dropping abuse or misuse is not covered by the warranty.
Outside the warranty period we offer a full repair and re-calibration service.
Maintenance
WARNING Do not attempt to repair or service you meter unless you are qualified to do so and have the relevant calibration, performance test and service information.
To avoid electrical shock or damage to the meter do not get water inside the case.
Periodically wipe the case with a damp cloth and mild detergent. Do not use chemical solvent.
Clean the input terminal with cotton bud, as dirt or moisture in the terminal can affect readings.
Di-Log Test Equipment
28 Wheel Forge Way,
Trafford Park,
Manchester
M17 1EH, UK
tel: + 44 161 877 0322 fax: + 44 161 877 1614
email: [email protected] website: www.dilog.co.uk
Advertisement
Key features
- Autoranging
- 6000 counts LCD display
- Data hold
- Auto power off
- Low battery indicator
- Temperature measurement
- Diode test
- Continuity check
- Frequency measurement
- Duty cycle measurement