FUJITSU Server PRIMERGY BX2580 M1 Server Blade

Add to my manuals
68 Pages

advertisement

FUJITSU Server PRIMERGY BX2580 M1 Server Blade | Manualzz

Operating Manual - English

FUJITSU Server PRIMERGY BX2580 M1

Server Blade

Operating Manual

Edition December 2014

CommentsSuggestionsCorrections

The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to email: [email protected]

.

Certified documentation according to DIN EN ISO 9001:2008

To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard

DIN EN ISO 9001:2008. cognitas. Gesellschaft für Technik-Dokumentation mbH www.cognitas.de

Copyright and Trademarks

Copyright © 2014 Fujitsu Technology Solutions GmbH.

All rights reserved.

Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

– The contents of this manual may be revised without prior notice.

– Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

– No part of this manual may be reproduced in any without the prior written permission of

Fujitsu.

Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of

Microsoft Corporation in the USA and other countries.

Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

Before reading this manual

For your safety

This manual contains important information for safely and correctly using this product.

Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product.

Radio interference

This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures.

VCCI-A

Aluminum electrolytic capacitors

The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke.

As a guideline, in a normal office environment (25°C) operating life is not expected to be reached within the maintenance support period (5 years).

However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life.

Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period.

High safety use

This product has been designed and manufactured to be used in commercial and/or industrial areas as a server.

When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems).

The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured.

BX2580 M1

Operating Manual

These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.

Measures against momentary voltage drop

This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.

(This notice follows the guidelines of Voltage Dip Immunity of Personal

Computer issued by JEITA, the Japan Electronics and Information Technology

Industries Association.)

Technology controlled by the Foreign Exchange and Foreign Trade

Control Law of Japan

Documents produced by Fujitsu may contain technology controlled by the

Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law.

Harmonic Current Standards

This product conforms to harmonic current standard JIS C 61000-3-2.

Only for the Japanese market:

About SATA hard disk drives

The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used.

Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive:

http://jp.fujitsu.com/platform/server/primergy/harddisk/

Operating Manual

BX2580 M1

Only for the Japanese market:

I

Although described in this manual, some sections do not apply to the

Japanese market. These options and routines include:

– CSS (Customer Self Service)

BX2580 M1

Operating Manual

Operating Manual

BX2580 M1

4

4.1

4.2

4.3

4.4

4.5

4.6

5

5.1

5.2

5.3

5.4

2

2.1

2.2

3

Contents

1

1.1

1.2

1.3

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Concept and target groups for this manual . . . . . . . . . . 9

Documentation overview . . . . . . . . . . . . . . . . . . . 10

Notational conventions . . . . . . . . . . . . . . . . . . . . 11

Functional overview . . . . . . . . . . . . . . . . . . . . . . 13

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Server specification . . . . . . . . . . . . . . . . . . . . . . 21

Installation steps, overview . . . . . . . . . . . . . . . . . . 27

Important information . . . . . . . . . . . . . . . . . . . . . 29

Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 29

CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 35

FCC class A device . . . . . . . . . . . . . . . . . . . . . . . 36

Transporting the Server Blade . . . . . . . . . . . . . . . . 36

Notes on installation in the system unit . . . . . . . . . . . 36

Environmental protection . . . . . . . . . . . . . . . . . . . 37

Hardware installation . . . . . . . . . . . . . . . . . . . . . . 39

Unpacking the server blade . . . . . . . . . . . . . . . . . . 40

Installing the server blade in the system unit . . . . . . . . 40

Connecting devices . . . . . . . . . . . . . . . . . . . . . . 44

Instructions for connecting/disconnecting cables . . . . . . 45

BX2580 M1

Operating Manual

7

7.1

8

8.1

8.2

8.3

8.4

8.5

8.6

8.7

8.8

8.9

Contents

6

6.1

6.2

6.3

6.3.1

6.3.2

6.3.3

6.3.4

6.3.5

6.3.6

6.3.7

6.4

Starting up and operation . . . . . . . . . . . . . . . . . . . . 49

Control and display elements . . . . . . . . . . . . . . . . . 49

Switching the Server Blade on and off . . . . . . . . . . . . . 54

Configuring the Server Blade . . . . . . . . . . . . . . . . . . 55

Preparing for local installation . . . . . . . . . . . . . . . . . . 55

Preparation for remote installation to use Advanced Video

Redirection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Configuring the onboard SATA controller . . . . . . . . . . . . . 58

Configuring the SAS/SATA RAID controller . . . . . . . . . . . . 58

Configuring the onboard CNA controller . . . . . . . . . . . . . 59

Configuring the server and installing the operating system with the ServerView Installation Manager . . . . . . . . . . . . . 59

Configuring the server and installing the operating system without ServerView Installation Manager . . . . . . . . . . . . . 61

Cleaning the Server Blade . . . . . . . . . . . . . . . . . . . 62

Property and data protection . . . . . . . . . . . . . . . . . . 63

BIOS Setup security functions . . . . . . . . . . . . . . . . . 63

Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 65

Server switches itself off . . . . . . . . . . . . . . . . . . . . 65

Screen remains blank . . . . . . . . . . . . . . . . . . . . . . 65

Flickering stripes on monitor screen . . . . . . . . . . . . . 66

No screen display or display drifts . . . . . . . . . . . . . . . 67

Incorrect date and time . . . . . . . . . . . . . . . . . . . . . 67

System will not boot . . . . . . . . . . . . . . . . . . . . . . . 67

Hard disk drive error messages at system boot . . . . . . . 68

Added drive reported as defective . . . . . . . . . . . . . . . 68

Error message on screen . . . . . . . . . . . . . . . . . . . . 68

Operating Manual

BX2580 M1

1 Introduction

The PRIMERGY BX2580 M1 server blade is an Intel-based dual-socket server blade. It is ideal for use in data centers belonging to enterprises or Internet service providers, and makes an excellent large application server, terminal server for compute-intensive applications or DBMS server.

Security functions in the BIOS Setup protect the data on the server blade from unauthorized changes.

The server blade occupies only one bay in the PRIMERGY BX900/BX400 system unit.

I

You can find information about assembling, starting up and operating the system unit in the relevant operating manual.

1.1

Concept and target groups for this manual

This operating manual describes how to install, set up and operate your server blade.

This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY BX2580 M1 server blade into operation.

To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.

BX2580 M1

Operating Manual 9

Introduction

1.2

Documentation overview

More information on your PRIMERGY BX2580 M1 server blade can be found in the following documents:

– "ServerView Quick Start Guide"

– "Safety Notes and Regulations" manual

" 安全上のご注意 " for the Japanese market

– "Warranty" manual

" 保証書 " for the Japanese market

– "PRIMERGY ServerView Suite Local Service Concept - LSC" manual

– "Returning used devices" manual and "Service Desk" leaflet

" サポー ト &サービ ス " for the Japanese market

– FUJITSU Server PRIMERGY BX2580 M1 Server Blade Upgrade and

Maintenance Manual

– D3321 BIOS Setup Utility for FUJITSU Server PRIMERGY BX2580 M1

Reference Manual

– "LSI MegaRAID - SAS Software User Guide"

– "Modular RAID Controller / Modular SAS HBA Installation Guide"

I

All documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at:

– For the global market

http://manuals.ts.fujitsu.com

– For the Japanese market:

http://jp.fujitsu.com/platform/server/primergy/manual

The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at:

– For the global market:

ftp://ftp.ts.fujitsu.com/images/serverview/manuals

– For the Japanese market:

http://jp.fujitsu.com/primergy/downloads

I

For the Japanese market:

Before using the product, please check for additional information that may be available under the following URL:

http://jp.fujitsu.com/platform/server/primergy/products/note/

10 Operating Manual

BX2580 M1

Introduction

Further sources of information:

– ServerView Suite Glossary

– Manual for the monitor

– Documentation for the boards and drives

– Operating system documentation

– Information files in your operating system

1.3

Notational conventions

The following notational conventions are used in this manual:

Text in italics

indicates commands or menu items.

"Quotation marks" indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V

CAUTION!

pay particular attention to texts marked with this symbol.

Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

BX2580 M1

Operating Manual 11

Introduction

12 Operating Manual

BX2580 M1

2 Functional overview

The PRIMERGY BX2580 M1 server blade is an Intel-based dual-socket server blade. It is ideal for use in data centers belonging to enterprises or Internet service providers, and makes an excellent large application server, terminal server for compute-intensive applications or DBMS server.

2.1

Features

Intel

®

Xeon

®

processor

The server blade is equipped with an Intel

®

Xeon

®

processor E5-2600 v3 family for high-speed data processing.

Customer Self Service (CSS)

The PRIMERGY Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios.

In the CSS concept, you can replace the following components yourself in the event of an error:

– Non hot-plug SSD modules

– Memory modules

– Expansion cards

For information on replacing these components, see the "FUJITSU Server

PRIMERGY BX2580 M1 Server Blade Upgrade and Maintenance Manual".

CSS indicators on the control panel of the PRIMERGY server provide you with information if a CSS event arises.

In addition, CSS errors are displayed in the ServerView Operations Manager, the server management software from Fujitsu.

In the event of errors, the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question. (This feature is not available for the Japanese market.)

BX2580 M1

Operating Manual 13

Functional overview

I

Further information on the CSS concept is provided in the "PRIMERGY

ServerView Suite Local Service Concept - LSC" manual on the Fujitsu manuals server.

For the latest information on optional products provided for the

BX2580 M1 Server Blade see the configurator of the server:

http://ts.fujitsu.com/products/standard_servers/index.html

(for the global market)

http://jp.fujitsu.com/platform/server/primergy/system/

(for the Japanese market)

System board

The features of the system board are described in the Upgrade and

Maintenance Manual for the hardware.

Trusted Platform Module (TPM)

A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive

Encryption).

The TPM is activated via the BIOS system (for more information, refer to the

“D3321 BIOS Setup Utility for FUJITSU Server PRIMERGY BX2580 M1

Reference Manual").

V

CAUTION!

– When using the TPM, note the program descriptions provided by the third party manufacturers.

– You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the

TPM or the system board is faulty you will not be able to access your data.

– If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content.

14 Operating Manual

BX2580 M1

Functional overview

Solid state drives (SSD)

The server blade can be equipped with a maximum of two 1.8-inch SSD modules.

Two SATA SSD drives can be controlled by the onboard SATA controller or the

SAS/SATA RAID controller.

Onboard CNA controller

A CNA controller is integrated on the system board; up to 4 x 1 Gbit/s or

2x 10 Gbit/s can be selected on the CNA controller.

For more information on configuring the controller, see section "Configuring the onboard CNA controller" on page 59

.

Onboard SATA controller

A SATA controller is integrated on the system board; up to two SATA SSD drives can be connected to the controller. The LSI Embedded MegaRAID software

(SATA Software RAID) supports RAID levels 0 and 1.

For more information on configuring the controller, see section "Configuring the onboard SATA controller" on page 58

.

BX2580 M1

Operating Manual 15

Functional overview

SAS/SATA RAID controller

The server blade is available with the following SAS/SATA RAID controllers for operating the internal SATA SSD drives:

– SAS RAID Mezzanine card with "MegaRAID functionality" (SAS

MegaRAID) for SAS1.0 and SAS2.0.

RAID levels 0 and 1 are supported for internal SSD drive configurations.

I

For more information on configuring the controller, see section

"Configuring the SAS/SATA RAID controller" on page 58 .

Slots for expansion cards

The server blade supports two optional mezzanine cards. This enables Fibre

Channel connections, Infiniband connections and/or additional Ethernet connections to be implemented.

The following mezzanine cards are available for the server blade:

– Ethernet Mezzanine Card 4 x 1 Gbit/s PCIe x4 Fujitsu

– CNA Mezzanine Card 2 x 10 Gbit/s PCIe 2.0 x8 Emulex

– Ethernet Mezzanine Card 2 x 10 Gbit/s PCIe 2.0 x8 Fujitsu

– Fibre Channel Mezzanine Card 2 x 16 Gbit/s PCIe 3.0 x8 Emulex

– Fibre Channel Mezzanine Card 2 x 8 Gbit/s PCIe 2.0 x8 Emulex

– InfiniBand Mezzanine Card 2 x 56 Gbit/s PCIe 3.0 x8 Mellanox

– SAS HBA Mezzanine Card 2 x 6 Gbit/s PCIe 2.0 x8 Fujitsu

– SAS RAID Mezzanine Card 2 x 6 Gbit/s PCIe 2.0 x8 Fujitsu

16 Operating Manual

BX2580 M1

Functional overview

I

If a server blade is configured with one or two mezzanine cards, this does not exclude other configurations for any of the other server blades in a system unit.

If you want to install mezzanine cards in server blades, the system unit must be fitted with the corresponding Fibre Channel, SAS, Infiniband and/or Ethernet connection blades. You can find detailed information about the equipping rules for connection blades in the operating manual for the system unit.

Mezzanine cards may only be installed and removed by authorized, qualified personnel. The procedure is described in the FUJITSU Server

PRIMERGY BX2580 M1 Server Blade Upgrade and Maintenance

Manual.

USB flash module (UFM)

A UFM (USB flash module) can also be configured.

SATA DOM

DOM stands for "disk on module". It is an extremely space and energy saving flash memory that is particularly used as a boot drive in servers. The memory technology is equivalent to that of SSDs. The PRIMERGY BX2580 M1offers a

DOM with a SATA 3G interface, which can be inserted directly into the SATA port of the system board.

Graphics controller

The server blade has an onboard graphics controller (integrated in the iRMC controller). A monitor can be connected via the Y-cable on the front of the server blade.

I

For peripherals like keyboard, mouse, display, optical drive, etc.

Advanced Video Redirection and Virtual Media connection by iRMC is recommended.

External ports

The server blade has the following ports on the front:

– One USB 3.0 port

– One port for a special Y-cable, with 2 USB 2.0 ports and one VGA port.

BX2580 M1

Operating Manual 17

Functional overview

High level of availability and data security

When memory data is accessed, 1-bit errors are identified in the main memory and automatically corrected with the error correcting code (ECC) method.

ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the event of an error and automatically "hides" the defective system components.

The PDA (Prefailure Detection and Analyzing) technology from Fujitsu

Technology Solutions analyzes and monitors all components that are critical for system reliability.

iRMC with integrated management LAN connector

I

The server blade can use iRMC Advanced Video Redirection and Virtual

Media as a standard function. Therefore, the license key to the option is unnecessary.

The iRMC (integrated Remote Management Controller) is a Baseboard

Management Controller (BMC) with integrated management LAN connector and expanded functionality that was previously only available with additional plug-in cards. In this way, the iRMC enables complete control of PRIMERGY servers, regardless of system status, and thus particularly the control of

PRIMERGY servers that are in the "out-of-band" system status.

Major functions supported by the iRMC include the following:

Browser access via iRMC’s own web server

Secure communication (SSH, SSL)

Power Management for the managed server (depending on its system status)

Power Consumption Management

Connecting virtual drives as remote storage

Text-based and graphic console bypass (Advanced Video Redirection)

Virtual Media

Command Line Interface (CLI)

Simple, interactive or script-based iRMC configuration

Customer Self Service (CSS) iRMC’s own user management

18 Operating Manual

BX2580 M1

Functional overview

Multi-computer, global iRMC user administration using an LDAP Directory

Service

Automatic network configuration via DNS / DHCP

Power supply of the iRMC via the system standby supply

Full-coverage alarm management

System Event Log (SEL) reading and processing

IPMI support

CIM / WS-MAN support

Internal Event Log for user login/logout auditing

More information about the iRMC can be found in the "iRMC S4 - integrated

Remote Management Controller" user guide (on the Fujitsu manual server under x86 Servers - Software - ServerView Suite - Out-Of-Band Management).

Server management

Server management is implemented using the ServerView Operations Manager supplied and the PDA (Prefailure Detection and Analysis) technology from

Fujitsu. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken.

The ServerView Operations Manager enables the management of all

PRIMERGY servers in the network via a central console. The ServerView

Operations Manager supports the following functions:

Round-the-clock monitoring, regardless of server status

High-performance, graphical console bypass (AVR) protected by

HTTPS/SSL (128 bit)

Virtual Media via USB

Remote power on

Temperature monitoring of the CPU and the surrounding area

Detailed status and error reports for processors and main memory

Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event that memory modules or processors fail

Power monitoring

End-of-life monitoring of fans with prompt notification before failure

BX2580 M1

Operating Manual 19

Functional overview

Watchdog timer for monitoring the operating system with ASR&R

Further information on the ServerView Operations Manager is provided in the associated documentation.

ServerView Installation Manager

You can configure the PRIMERGY server quickly and precisely with the

ServerView Installation Manager software provided. User-guided menus are available for installing the server operating system (for further details see section

"Configuring the Server Blade" on page 55 ).

Service and support

PRIMERGY servers are service-friendly and modular, thus enabling quick and simple maintenance. The two redundant hot-pluggable management blades of the system unit, with independent LAN and COM ports for management, enable comprehensive remote administration of the server blade. Together, they allow remote diagnosis for system analysis, remote configuration and remote restart, even in the case of operating system failure or hardware errors.

20 Operating Manual

BX2580 M1

Functional overview

2.2

Server specification

This section explains the specifications for the server blade. The specifications for this server blade are liable to be updated without any notice. Please be forewarned.

System Board

System board type

Chipset

D3321

Intel

®

C610

Processor

Processor quantity and type

2 x Intel

®

Xeon

®

processor E5-2600 v3 product family

Memory modules configuration

Memory slots

Memory slot type

Memory capacity

(min. - max.)

Memory protection

24slots (4 channels per CPU with 3 slots each)

DIMM (DDR4)

8 GB - 1536 GB

Memory notes

Advanced ECC; Memory Scrubbing, SDDC

(Chipkill™); Memory Mirroring support; Rank sparing memory support

Memory Mirroring with identical modules in both channel pairs of a bank (4 modules per bank), Rank sparing or Performance Mode with the spare rank module having identical or larger memory capacity than all the other ranks on the same channel

Interfaces

USB connectors

Graphics (15-pin)

2 x USB 2.0 (via Y-cable);

1 x USB 3.0 at the front side; 1 x USB 3.0 internal

1 x VGA via Y-cable (front)

BX2580 M1

Operating Manual 21

Functional overview

Onboard or integrated controllers

RAID Controller

SATA Controller

CNA Controller

Remote Management

Controller

Trusted Platform

Module (TPM)

SAS RAID Mezzanine card with "MegaRAID functionality" (SAS MegaRAID) for SAS1.0 and

SAS2.0. RAID levels 0 and 1 are supported for internal SSD configurations.

A 10-port SATA controller is integrated on the system board; up to two SATA drives can be connected to the controller. The LSI Embedded MegaRAID software (SATA Software RAID) supports RAID levels 0 and 1.

The CNA controller is integrated on the system board; up to 4 x 1 Gbit/s or 2x 10 Gbit/s can be selected on the CNA controller.

Integrated Remote Management Controller

(iRMC S4), 8 MB video memory, IPMI 2.0 compatible

Infineon / 1.2 (option)

Disk drives

Drive configuration 2x 1.8-inch SATA SSD modules

22 Operating Manual

BX2580 M1

Functional overview

Operating panel

Operating buttons

Status LEDs

On/off button

ID button

Power indicator (orange / green / light-green)

ID indicator (blue)

Global error indicator (orange)

CSS indicator (orange)

I/O indicator: fabric 1 (green)

I/O indicator: fabric 2 (green)

I/O indicator: fabric 3/4 (green)

Dimensions / Weight

Width

Depth

Height

Weight

Weight notes

45 mm

508 mm

210.5 mm (1 bay in the system unit)

Max. 5.3 kg

Weight may vary depending on actual configuration

Ambient conditions

Environment class 3K2

Environment class 2K2

Temperature:

Operation (3K2)

Transport (2K2)

Humidity

EN 60721 / IEC 721 Part 3-3

EN 60721 / IEC 721 Part 3-2

5°C ... 35°C

-20°C ... 60°C

10% ... 85% (non condensing)

Condensation during operation must be avoided!

BX2580 M1

Operating Manual 23

Functional overview

Electrical specifications

Power consumption

Thermal dissipation

511.7 W (full configuration)

1.842 kJ/h

Compliance with regulations and standards

Product safety and ergonomics

International

Europe

IEC 60950-1 2ed; am1

Safety

Ergonomics

USA / Canada

EN 60950-1 2ed.; am1

EN 62479

EN 62311

ISO 9241-3

EN 2941-3

EK1-ITB2000:2013

CSA-C22.2 No. 60950-1-07 2ed.

UL 60950-1 2ed.

Taiwan

China

Electromagnetic compatibility

International CISPR 22

Europe

CNS 14336

GB 4943

USA / Canada

Taiwan

EN 55022 Class A

EN 55024

EN 61000-3-2

EN 61000-3-3

ETSI 300386

47CFR part 15 Class A / ICES-003

CNS 13438 Class A

China

Japan

Korea

CE marking to EU directives

GB 9245 / GB 17625

VCCI Class A / JEITA

KN 22 / KN 24

Low Voltage Directive 2006/95/EC

Electromagnetic compatibility 2004/108/EC

Restriction of hazardous substances 2011/65/EU

24 Operating Manual

BX2580 M1

Certification

Product safety approved with the system unit

Global

Germany

CB

GS, CE

USA/Canada

Japan

China/Taiwan

CSA

US

/CSA

C

VCCI

BSMI

Functional overview

BX2580 M1

Operating Manual 25

Functional overview

26 Operating Manual

BX2580 M1

3 Installation steps, overview

This chapter contains an overview of the steps necessary to install your

Server Blade. The cross-references take you to the sections containing more detailed information on the relevant installation step:

Ê

First read the chapter "Important information" on page 29

, particularly the

section "Safety instructions"

.

Ê

Unpack the Server Blade, check the contents of the package for visible transport damage and check whether the items delivered correspond to the

details on the delivery note (see section "Unpacking the server blade" on page 40 ).

Ê

Transport the server blade to the place where you want to set it up.

Ê

Make sure that you have all necessary manuals (see

page 10

); print out the

PDF files if required.

Ê

Install the server blade in your system unit (see section

"Installing the server blade in the system unit" on page 40

).

Ê

Familiarize yourself with the controls and indicators on the front of the server blade (see

chapter "Starting up and operation" on page 49

).

Ê

Install the operating system and applications on the server blade.

When doing so, you have the following options:

Clone the server blade from a remote image server using the ServerView

Deployment Manager. Cloning the ServerView Deployment Manager from a

remote image server.

This procedure is recommended if the following conditions are met:

– ServerView Deployment Manager software is available.

– You have a suitable clone image.

– A Deployment Server and LAN connection are available.

Remote installation with ServerView Installation Manager

This installation method is recommended if you have a LAN connection and a DHCP server (Deployment Server) available, but the cloning requirements are not met.

BX2580 M1

Operating Manual 27

Installation steps, overview

Local installation with or without ServerView Installation Manager

Local installation is the least convenient method. It is only recommended if the requirements for remote installation and cloning are not met.

If you want to install an operating system that is not supported by

ServerView Installation Manager, you can of course install it directly without

ServerView Installation Manager.

I

For more information about installing the server remotely or locally, please refer to the "ServerView Installation Manager" user guide. You can find a description of how to clone server blades in the ServerView

Deployment Manager user guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Server Installation and

Deployment).

28 Operating Manual

BX2580 M1

4 Important information

This chapter provides safety instructions which you must observe when handling your server.

4.1

Safety instructions

I

The following safety instructions are also provided in the manual "Safety

Notes and Regulations" or " 安全上のご注意 ".

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.

V

CAUTION!

The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software.

Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices.

Also unplug all power cords from the power outlet. Failure to do so can cause electric shock.

BX2580 M1

Operating Manual 29

Important information

Before starting up

V

CAUTION!

During installation and before operating the device, observe the instructions on environmental conditions for your device (see

"Server specification" on page 21 ).

If the server has been moved from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the server if this requirement is not met.

Only transport the server in the original packaging or in packaging that protects it from impacts and jolts.

Installation and operation

V

CAUTION!

The device may only be operated in a maximum ambient temperature of 35°C.

If the device is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for non-industrial (public) power supply networks for the type A connector.

The On/Off button or the main power switch (if there is one) does not disconnect the device from the mains voltage. To completely disconnect it, you must remove all the power plugs from the power outlets.

Data cables must be adequately shielded to avoid interference.

Do not connect or disconnect any data transmission cables during a thunderstorm (lightning hazard).

Make sure that no objects (e.g. bracelets or paper clips) fall into or liquids spill into the device (risk of electric shock or short circuit).

30 Operating Manual

BX2580 M1

Important information

V

CAUTION!

In emergencies (e.g. damaged casing, control elements or power cable, penetration of liquids or foreign bodies), switch off the device immediately, unplug it from the grounded power outlets, and contact your customer service center.

Proper operation of the device (in accordance with IEC 60950-

1/EN 60950-1) is only ensured if the casing is fully assembled and the rear covers for the installation bays are in place (electric shock, cooling, fire protection, interference suppression).

Install only system extensions that satisfy the requirements and rules governing safety, electromagnetic compatibility, and telecommunications terminal equipment. If you install other extensions, you may damage the system or violate these safety regulations. You can find out which system extensions are suitable from the customer service center or your sales outlet.

The components marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced.

If you cause a defect on the device by installing or exchanging system extensions, the warranty will be invalidated.

Only set the resolutions and refresh rates specified in the operating manual for your monitor. Otherwise, you may damage the monitor. If you are in any doubt, contact your sales outlet or customer service center.

BX2580 M1

Operating Manual 31

Important information

Batteries

V

CAUTION!

Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (refer to the "FUJITSU Server

PRIMERGY BX2580 M1 Server Blade Upgrade and Maintenance

Manual").

Do not throw batteries into the trash can.

Batteries must be disposed of in accordance with local regulations concerning special waste.

Replace the lithium battery on the system board in accordance with the instructions in the "FUJITSU Server PRIMERGY BX2580 M1

Server Blade Upgrade and Maintenance Manual".

All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium

Hg Mercury

Pb Lead

Working with CDs/DVDs/BDs and optical drives

When working with devices with optical drives, these instructions must be followed.

V

CAUTION!

Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury.

Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance.

Damaged and imbalanced CDs/DVDs/BDs can break at high drive speeds (data loss).

32 Operating Manual

BX2580 M1

Important information

Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

High humidity and airborne dust levels are to be avoided. Electric shocks and/or server failures may be caused by liquids such as water, or metallic items, such as paper clips, entering a drive.

Shocks and vibrations are also to be avoided.

Do not insert any objects other than the specified CDs/DVDs/BDs.

Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray roughly.

Do not disassemble the optical drive.

Before use, clean the optical disk tray using a soft, dry cloth.

As a precaution, remove disks from the optical drive when the drive is not to be used for a long time. Keep the optical disk tray closed to prevent foreign matter, such as dust, from entering the optical drive.

Hold CDs/DVDs/BDs by their edges to avoid contact with the disk surface.

Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth.

Be careful not to damage the CD/DVD/BD surface.

Keep the CDs/DVDs/BDs away from heat sources.

Do not bend or place heavy objects on CDs/DVDs/BDs.

Do not write with ballpoint pen or pencil on the label (printed) side.

Do not attach stickers or similar to the label side. Doing so may cause rotational eccentricity and abnormal vibrations.

When a CD/DVD/BD is moved from a cold place to a warm place, moisture condensation on the CD/DVD/BD surface can cause data read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth then let it air dry. Do not dry the CD/DVD/BD using devices such as a hair dryer.

BX2580 M1

Operating Manual 33

Important information

To avoid dust, damage, and deformation, keep the CD/DVD/BD in its case whenever it is not in use.

Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided.

I

You can prevent damage from the optical drive and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions:

– Only insert disks in the drive when needed and remove them after use.

– Store the disks in suitable sleeves.

– Protect the disks from exposure to heat and direct sunlight.

Laser information

The optical drive complies with IEC 60825-1 laser class 1.

V

CAUTION!

The optical drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the optical drive casing!

Modules with Electrostatic-Sensitive Devices

Modules with electrostatic-sensitive devices are identified by the following sticker:

Figure 1: ESD label

When you handle components fitted with ESDs, you must always observe the following points:

34 Operating Manual

BX2580 M1

Important information

Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs.

You must always discharge static build-up (e.g. by touching a grounded object) before working with such components.

Any devices or tools that are used must be free of electrostatic charge.

Wear a suitable grounding cable that connects you to the external chassis of the system unit.

Always hold components with ESDs at the edges or at the points marked green (touch points).

Do not touch any connectors or conduction paths on an ESD.

Place all the components on a pad which is free of electrostatic charge.

I

For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1,

ANSI/ESD S20.20).

Other important information:

During cleaning, observe the instructions in section

"Cleaning the Server

Blade" on page 62

.

Keep this operating manual and the other documentation (such as the

Upgrade and Maintenance Manual, documentation DVD) close to the device. All documentation must be included if the equipment is passed on to a third party.

4.2

CE conformity

The system complies with the requirements of the EC directives

2004/108/EC regarding "Electromagnetic Compatibility" and

2006/95/EC "Low Voltage Directive" and the directive of the

European Parliament and Council 2011/65/EU. This is indicated by the CE marking (CE = Communauté Européenne).

BX2580 M1

Operating Manual 35

Important information

4.3

FCC class A device

V

Warning!

This is a class A product, which may cause radio interference in a domestic environment. If this is the case, the user may be required to take adequate measures.

4.4

Transporting the Server Blade

V

CAUTION!

Only transport the server blade in its original packaging or in suitable packaging which protects it from knocks and jolts.

For the Japanese market it is not required to transport the device in its original packaging.

Do not unpack the server blade until it is at its installation location.

4.5

Notes on installation in the system unit

V

CAUTION!

Beware of the energy hazard at the midplane contacts of the system unit.

A short circuit on these contacts may damage the system.

36 Operating Manual

BX2580 M1

Important information

4.6

Environmental protection

Environmentally-friendly product design and development

This product has been designed in accordance with the Fujitsu standard for

"environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.

This saves resources and thus reduces the harm done to the environment.

Further information can be found at:

http://ts.fujitsu.com/products/standard_servers/index.html

(for the global market)

http://jp.fujitsu.com/platform/server/primergy/concept/

(for the Japanese market)

Energy-saving information

Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work.

Packaging information

This packaging information doesn’t apply to the Japanese market.

Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging.

Information on handling consumables

Please dispose of printer consumables and batteries in accordance with the applicable national regulations.

In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal.

All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants:

Cd Cadmium

Hg Mercury

Pb Lead

BX2580 M1

Operating Manual 37

Important information

Labels on plastic casing parts

Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them.

Returns, recycling and disposal

Please handle returns, recycling and disposal in accordance with local regulations.

The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive

2002/96/EC on waste electrical and electronic equipment (WEEE).

This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at

http://ts.fujitsu.com/recycling

.

Details regarding the return and recycling of devices and consumables within

Europe can also be found in the "Returning used devices" manual, via your local

Fujitsu branch or from our recycling center in Paderborn:

Fujitsu Technology Solutions

Recycling Center

D-33106 Paderborn

Tel. +49 5251 525 1410

Fax +49 5251 525 32 1410

38 Operating Manual

BX2580 M1

5 Hardware installation

V

CAUTION!

Follow the safety instructions in the chapter "Important information" on page 29

.

Do not expose the server to extreme environmental conditions (see

"Ambient conditions" on page 23

). Protect the server from dust, humidity and heat.

Make sure that the server is acclimatized for the time indicated in this table before putting it into operation.

Temperature difference (°C) Minimum acclimatization time

(hours)

5

10

3

5

15

20

25

30

7

8

9

10

Table 1: Acclimatization time

In the

table "Acclimatization time"

, the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously (outside, transport or storage temperature).

BX2580 M1

Operating Manual 39

Hardware installation

5.1

Unpacking the server blade

V

CAUTION!

Follow the safety instructions in chapter "Important information" on page 29 .

Do not unpack the server blade until it is at its installation location.

Ê

Transport the server blade to the place where you want to set it up.

Ê

Unpack all individual parts.

Keep the original packaging in case you want to transport the server blade again (does not apply to the Japanese market).

Ê

Check the delivery for any damage during transport.

Ê

Check whether the items delivered match the details on the delivery note.

The product name and serial number of the product can be found on the ID card

(see section

"ID card" on page 53 ).

Ê

Notify your supplier immediately in case you discover that the items delivered do not correspond to the delivery note.

5.2

Installing the server blade in the system unit

V

CAUTION!

Note the safety instructions and the information on handling

electrostatically sensitive devices in section "Safety instructions" on page 29 .

Note the population rules for power supply units and fan modules to ensure sufficient cooling of the system. You will find more detailed information on this in the operating manual for the system unit.

Removing the dummy module

Any unused slots on the front of the system unit are fitted with appropriate dummy modules to comply with electromagnetic compatibility (EMC) regulations and to ensure sufficient cooling of the system components.

40 Operating Manual

BX2580 M1

Hardware installation

To add a server blade, you must first remove a dummy module from the relevant slot.

Figure 2: Removing the server blade dummy module

Ê

Pull up the handle of the dummy module (arrow) to unlock it.

Ê

Pull the dummy module out of the slot.

V

CAUTION!

Keep the dummy module for future use. If you remove a server blade and do not replace it with a new one, you must install a dummy module to comply with the regulations regarding electromagnetic compatibility and to ensure sufficient cooling of the system components.

Installing the dummy module

To install the dummy module, follow the same procedure as for removing it, except in reverse order.

BX2580 M1

Operating Manual 41

Hardware installation

Installing the server blade

V

CAUTION!

Follow the safety instructions and information in section "Modules with

Electrostatic-Sensitive Devices" on page 34 .

Figure 3: Installing the server blade

Ê

Open the release lever.

Ê

Push the server blade as far as possible into the slot.

42 Operating Manual

BX2580 M1

Hardware installation

Figure 4: Locking the server blade

Ê

Push the release lever up until it engages.

Removal is carried out in reverse order.

V

CAUTION!

If you remove a server blade and do not replace it with a new one, you must install a dummy module to comply with the regulations regarding electromagnetic compatibility and to ensure sufficient cooling of the system components.

BX2580 M1

Operating Manual 43

Hardware installation

5.3

Connecting devices

All connections that are required to operate the server blade are made via the midplane of the system unit. When the server blade is installed, midplane contacts automatically establish connections to the infrastructure modules on the rear of the system unit:

– Power supply units

– Management blade(s) for server administration

– Ethernet and/or fiber-channel connection blades for connection to a LAN or

SAN

You can find information about the external ports of the system unit in the relevant operating manual.

The front of the server blade has a port for a special Y-cable, which provides 2

USB ports and 1 VGA port. An additional USB port is available on the front of the server blade.

44 Operating Manual

BX2580 M1

Hardware installation

Figure 5: Ports on the front

1

2

3

USB connector (2x)

VGA connector

Plug connection to the server blade.

The labeled side of the plug must face left when plugged in.

4

5

Y-cable connector on the server blade

Front USB port

I

The Y-cable is delivered with the system unit.

5.4

Instructions for connecting/disconnecting cables

V

CAUTION!

Be sure to read the documentation for the peripheral devices before connecting them.

Do not connect or disconnect data cables during a thunderstorm.

When removing a cable, always hold it by the plug. Never unplug a cable by pulling at the cable itself.

Connect and disconnect the cables in the order described below.

BX2580 M1

Operating Manual 45

Hardware installation

Connecting cables

I

For peripherals like keyboard, mouse, display, optical drive, etc.

Advanced Video Redirection and Virtual Media connection by iRMC is recommended.

Ê

Turn off the power of the target server blade and all peripherals.

Ê

Disconnect all power plugs of the peripherals from the grounded shockproof sockets.

Ê

Connect the Y-cable to the server blade.

Ê

Connect all peripherals to the connectors of the Y-cable.

Ê

Plug all power plugs of the peripherals to the grounded shockproof sockets.

Disconnecting cables

Ê

Turn off the target server blade.

Ê

Turn off the all connected peripherals

Ê

Disconnect all power plugs of the peripherals from the grounded shockproof sockets.

Ê

Disconnect all peripherals from the Y-cable.

Ê

Disconnect the Y-cable from the server blade.

46 Operating Manual

BX2580 M1

Hardware installation

Using the Y-cable

I

When engaging between the Y-cable connector and the server blade connector is strong, and the Y cable is detached as it is, the Y-cable connector might be damaged.

Therefore, please remove the Y-cable as follows.

Procedure for detaching the Y-cable

While strongly pushing the hook of the Y-cable connector (server blade side: 2 points),

– push it toward the server blade strongly,

– and remove it straight

Figure 6: BX900 / BX400 system unit (rack version)

BX2580 M1

Operating Manual 47

Hardware installation

Figure 7: BX400 S1 system unit (floorstand version)

Important

You may find it difficult to remove the Y-cable because the load hangs in the join with the Y-cable connector.

Therefore make sure it is straight when you remove it.

Do not leave a Y-cable connected.

Do not close the rack door while the Y-cable is connected, to avoid damaging the Y-cable.

48 Operating Manual

BX2580 M1

6 Starting up and operation

V

CAUTION!

Follow the safety instructions in the chapter "Important information" on page 29

.

6.1

Control and display elements

Figure 8: Control and display elements

1 ID card

2 I/O indicator: fabric 3/4

3 I/O indicator: fabric 2

4 I/O indicator: fabric 1

5 CSS indicator

6 Global Error indicator

7 ID button with ID indicator

8 On/Off button with power indicator

BX2580 M1

Operating Manual 49

Starting up and operation

Control elements

On/Off button

When the server blade is switched off, it can be switched on again by pressing the On/Off button.

When the server blade is operating, pressing the On/Off button will switch off the server blade .

V

CAUTION!

Risk of loss of data!

I

The On/Off button does not disconnect the server blade from the mains voltage. To disconnect it from the mains completely, remove it from the system unit.

ID

ID button

Lights up (blue) on the front of the server blade when the ID button is pressed.

If the ID button is pressed for more than 5 seconds, released and pressed again within 1 second, an NMI is issued.

50 Operating Manual

BX2580 M1

Starting up and operation

Indicators on the control panel

Power-on indicator (three colors)

Lights up green when the server is switched ON.

Lights up orange when the server is switched OFF, but mains voltage is present (standby mode).

I

After connecting the server to the mains, it will take about

60 seconds until the server will switch into standby mode.

Flashes light-green / orange: iRMC booting

I

After linking the server to the mains voltage (system unit is switched on / after mains failure) the iRMC will boot.

The system cannot be switched on, until the iRMC boot sequence is complete. During this time, the power-on indicator will flash light-green / orange.

Lights up light-green: power-on delay

I

After shutting down, the server cannot be switched on again right away. If the On/Off button is pressed right after shutting down the server, the power-on indicator will light up light-green until the delay period ends and the server will boot.

If line voltage is insufficient, the server cannot be switched on. If the On/Off button is pressed in this state, the power-on indicator will light up light-green.

BX2580 M1

Operating Manual 51

Starting up and operation

!

CSS

ID

Global Error indicator (orange)

Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention.

Flashes orange if an error was detected that requires service intervention.

Does not light up if there is no critical event.

If the event is still acute after a power failure, the indicator is activated after the restart.

The indicator also lights up in standby mode.

You can find more details on the indicated errors in the System

Event Log (SEL), in the Management Blade Web interface, on the ServerView Local Service Panel, on the ServerView Local

Service Display, in the ServerView Operations Manager or via the iRMC S4's Web interface.

CSS indicator (orange)

Lights up orange if a prefailure event was detected for a CSS component that you can fix yourself (for reasons of precaution) with the CSS concept.

Flashes orange if an error was detected that you can fix yourself with the CSS concept.

Does not light up when the system is OK.

If the event is still acute after a power cycle, the indicator is activated after the restart.

The indicator also lights up in standby mode.

For more information on the CSS concept, see "Customer Self

Service (CSS)" on page 13

.

ID indicator (blue)

Lights up blue when the system has been selected by pressing the

ID button. To deactivate, press the button again.

The ID indicator can also be activated via the ServerView

Operations Manager, the Management Blade web interface and the iRMC S4 web interface. Its status is reported to the ServerView

Operations Manager and the iRMC S4.

52 Operating Manual

BX2580 M1

Starting up and operation

I/O indicators* (green)

Lights up to indicate a network connection.

Flashes to indicate an active network connection.

Does not light up if there is no network connection.

* The three I/O fabrics of the server blade are:

– Fabric 1: onboard CNA controller

– Fabric 2: mezzanine card 1

– Fabric 3/4: mezzanine card 2

ID card

You can pull out the ID card (see figure 8 on page 49 ) as far as it will go and

push it back in again.

The ID card contains various system information, such as the product name, serial number, order number, MAC addresses and DNS name.

BX2580 M1

Operating Manual 53

Starting up and operation

6.2

Switching the Server Blade on and off

V

CAUTION!

If you switch the server blade on and flickering stripes appear on the connected monitor, switch the server blade off again immediately (see

chapter "Troubleshooting and tips" on page 65

).

The On/Off button does not disconnect the device from the mains. To fully disconnect the device from the mains, you must remove the server blade from the system unit or switch off the system unit and unplug the power plug(s).

Using the control panel to switch the Server Blade on and off

The system unit is switched on and the power-on indicator (item 8 in figure 8 on page 49

) is flashing light-green / orange.

The server blade can be switched on and off as follows:

– To switch the server blade on, press the On/Off button on the server blade

(item 8 in

figure 8 on page 49

).

To switch the server blade off, hold down the On/Off button on the server blade (item 8 in

figure 8 on page 49

) for 4 seconds.

Defined switch-On/Off time

The server blade is switched on and off at the times defined in the ServerView

Operation Manager.

Other On/Off options

After power failure

Once a server blade has been switched on, it will switch itself on again automatically after a power failure (irrespective of the setting in the BIOS

Setup).

I

You can also switch the server blade on and off via the system unit control panel or via the Web interface of the ServerView Management

Blade. Detailed information is provided in the manuals "PRIMERGY

BX900 Blade Server Systems ServerView Management Blade S1 User

Interface Description" or "PRIMERGY BX400 Blade Server Systems

ServerView Management Blade S1 User Interface Description".

54 Operating Manual

BX2580 M1

Starting up and operation

6.3

Configuring the Server Blade

This section contains information about configuring the server blade and installing the operating system.

The operating system can be installed in various ways:

– Local installation with or without the ServerView Installation Manager

You can find information on local installation in the following sections.

– Remote installation using console redirection via the user interface of the

ServerView Management Blade. Please refer to the following manuals for more information on Advanced Video Redirection:

– "PRIMERGY BX900 Blade Server Systems ServerView Management

Blade S1 User Interface Description"

– "PRIMERGY BX400 Blade Server Systems ServerView Management

Blade S1 User Interface Description"

– "iRMC S4 - integrated Remote Management Controller" user’s guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite

- Out-Of-Band Management)

Apart from this, the operating system installation is carried out in the same way as a local installation.

– Importing the clone images from an image repository to the desired server blades.

For more information about this procedure, see the "ServerView

Deployment Manager 5.0" manual (on the Fujitsu manuals server under x86

Servers - Software - ServerView Suite - Server Installation and Deployment).

6.3.1

Preparing for local installation

Connect the monitor, mouse, keyboard and a DVD drive to the port on the server blade control panel with the aid of the special Y cable. See

"Connecting devices" on page 44 .

I

Make sure that the energy saving functions are disabled in the Power menu of the BIOS Setup during operation, and that the DVD drive has been activated as a boot medium.

BX2580 M1

Operating Manual 55

Starting up and operation

6.3.2

Preparation for remote installation to use

Advanced Video Redirection

Advanced Video Redirection (AVR) can be used with the iRMC Web user interface and the Management Blade Web user interface. This section describes how to prepare for using the Web user interface for management blades.

I

For using the iRMC Web user interface, please refer to the "iRMC S4 - integrated Remote Management Controller" User's Guide (x86 Servers -

Software - ServerView Suite - Out-Of-Band Management on the Fujitsu manuals server.

1. The remote management terminal is connected to the network.

The remote control terminal (e.g. PC) is connected to a network that can connect to the management blade.

2. Network configuration

Network settings for the remote management terminal, management blade and iRMC.

a) Remote management terminal

Ê

Setup a remote network management station, if necessary.

b) Management blade

Ê

Start your Web browser on the remote control terminal and log on to the Management Blade Web user interface.

For details of the Management Blade Web user interface, please refer to the PRIMERGY BX400 Blade Server or PRIMERGY BX900

Blade Server manuals or the manual "ServerView Management

Blade S1 User Interface Description", chapter 4 "Web User

Interface".

Ê

Network setting of the management blade (Management LAN)

From the navigation frame of the Management Blade Web user interface, select each section: Setting - System Unit - Network Interface

- Management LAN.

Then set the network of the management blade on the "Ethernet" tab.

56 Operating Manual

BX2580 M1

Starting up and operation

I

For the PRIMERGY BX400 system unit, log onto the blade server and then switch to the Web user interface (Advanced) via the "Experience" drop-down list in the top right.

c) iRMC

1. Start your Web browser on the remote control terminal and log on to

Management Blade Web user interface.

2. Setting the iRMC network

Ê

From the navigation frame of the Management Blade Web user interface, select each section: Components - Server Blades - Server

Blade-x.

Ê

Then set the network of the iRMC in the "iRMC Address

Configuration" box.

For how to set the network, please refer to the "iRMC S4 - integrated

Remote Management Controller" User's Guide (chapter 3,

“Configuring the iRMC S4” under x86 Servers - Software - ServerView

Suite - Out-Of-Band Management on the Fujitsu manuals server.

Ê

If you want to use AVR from the remote control terminal connected to the management LAN port of the management blade, the LAN port of the iRMC must be set to "Management

LAN".

Ê

In addition, the iRMC and management LAN port of the management blade must also be set to the same network address.

3. Start the video redirection

Ê

The Video Redirection button will appear on the status frame when you select each section: Components - Server Blades - Server Blade-x.

Click this button to open the console screen of the server blade.

For details of the Management Blade Web user interface, please refer to the "ServerView Management Blade S1 User Interface Description" for the PRIMERGY BX400 Blade Server and the PRIMERGY BX900 Blade

Server.

I

For more on AVR and Virtual Media, please refer to the "iRMC S4

- integrated Remote Management Controller" User's Guide

("Advanced Video Redirection (AVR)” in chapter 5 and “Virtual

BX2580 M1

Operating Manual 57

Starting up and operation

Media Wizard” in chapter 6 under x86 Servers - Software -

ServerView Suite - Out-Of-Band Management on the Fujitsu manuals server.

6.3.3

Configuring the onboard SATA controller

A SATA controller is integrated on the system board. You can configure the onboard controller either before or during installation with the ServerView

Installation Manager. Using the ServerView Installation Manager is recommended.

I

A separate utility is available to the controller for MegaRAID configuration. For further information, refer to the "SAS Software User’s

Guide" (on the Fujitsu manuals server under x86 Servers - Expansion Cards

- Storage Adapters - LSI Configuration Software)

Further information on modular RAID controllers is provided in the

"Modular RAID Controller Installation Guide" (on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS /

SCSI RAID Controllers).

I

Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme under:

http://www.fujitsu.com/global/services/computing/server/ia/driver/index.html

(for the global market).

http://jp.fujitsu.com/platform/server/primergy/downloads/

(for the Japanese market).

I

In the system BIOS the SATA Mode can be configured as "AHCI Mode"

(default) or "RAID Mode".

6.3.4

Configuring the SAS/SATA RAID controller

The server blade has a SAS/SATA RAID controller with "MegaRAID functionality". You can configure the SAS/SATA RAID controller either before or during installation with the ServerView Installation Manager. Using the

ServerView Installation Manager is recommended.

I

A separate utility is available to the controller for MegaRAID configuration. For further information, refer to the "SAS Software User’s

Guide" (on the Fujitsu manuals server under x86 Servers - Expansion Cards

- Storage Adapters - LSI Configuration Software).

58 Operating Manual

BX2580 M1

Starting up and operation

Further information on modular RAID controllers is provided in the

"Modular RAID Controller Installation Guide" (on the Fujitsu manuals server under x86 Servers - Expansion Cards - Storage Adapters - LSI SAS /

SCSI RAID Controllers).

I

Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme under:

http://www.fujitsu.com/global/services/computing/server/ia/driver/index.html

(for the global market).

http://jp.fujitsu.com/platform/server/primergy/downloads/

(for the Japanese market).

6.3.5

Configuring the onboard CNA controller

A CNA controller is integrated on the system board. You can configure the onboard

CNA controller either before or during installation with the ServerView Installation

Manager. Using the ServerView Installation Manager is recommended.

I

The onboard CNA controller has its own configuration utility. Please refer the onboard CNA controller manuals as follows:

http://cmw3wbq1.emulex.com/downloads/fujitsu-technology-solutions.html

(for the global market).

http://jp.fujitsu.com/platform/server/primergy/manual/

(for the Japanese market).

6.3.6

Configuring the server and installing the operating system with the ServerView Installation Manager

Using the ServerView Installation Manager on the ServerView Suite DVD provided, you can conveniently configure the server and install the operating system. This includes configuring the server-specific settings using the

ServerView Configuration Manager and configuring the RAID controller using the ServerView RAID Manager.

Advantages of the ServerView Installation Manager

– Wizard assisted configuration of your server hardware and disk arrays

– Wizard assisted installation of all leading server operating systems

BX2580 M1

Operating Manual 59

Starting up and operation

– Wizard-assisted creation of configuration files for unattended installation of several PRIMERGY servers with identical hardware configurations.

– Installation of drivers and additional software.

I

The software that can be installed depends on your server’s hardware configuration. This configuration is detected automatically.

I

Descriptions of operating systems not covered in the RAID controller manual are provided in the corresponding readme files under:

http://www.fujitsu.com/global/services/computing/server/ia/driver/index.html

(for the global market).

http://jp.fujitsu.com/platform/server/primergy/downloads/

(for the Japanese market).

To find out how to operate the ServerView Installation Manager and for further information, refer to the associated manual.

If you are using the ServerView Installation Manager, you can skip the following section on how to configure the server and install the operating system.

Continue from section "Cleaning the Server Blade" on page 62 .

60 Operating Manual

BX2580 M1

Starting up and operation

6.3.7

Configuring the server and installing the operating system without ServerView Installation Manager

Configuring the onboard SATA controller

Configure the controller as described in section

"Configuring the onboard SATA controller" on page 58 .

Configuring the SAS/SATA RAID controller with "MegaRAID functionality"

Configure the controller as described in section

"Configuring the SAS/SATA

RAID controller" on page 58 .

Configuring the onboard CNA controller

Configure the controller as described in section

"Configuring the onboard CNA controller" on page 59 .

Installing the operating system

Ê

Insert the DVD for the operating system you want to install.

Ê

Reboot the server blade.

Ê

Follow the instructions on screen and in the manual for the operating system.

BX2580 M1

Operating Manual 61

Starting up and operation

6.4

Cleaning the Server Blade

V

CAUTION!

Switch off the server blade and remove it from the system unit (see

page 42 ).

Do not clean any interior parts of the server blade yourself; leave this job to a service technician.

Do not use abrasive powder or detergents which dissolve plastic to clean the housing exterior.

Make sure that no liquid gets inside the device and that the ventilation slits on the ServerBlade remain open.

Wipe the server blade housing with a dry cloth to clean. If it is very dirty you can use a damp cloth that has been dipped in water with a mild detergent and well wrung out.

62 Operating Manual

BX2580 M1

7 Property and data protection

The lockable rack door protects the server against unauthorized access.

To protect the system and data internally against unauthorized access, you can activate the security functions of the BIOS Setup.

7.1

BIOS Setup security functions

The Security menu in the BIOS Setup provides you with various options for protecting your data from unauthorized access. By combining these options, you can also achieve optimum protection for your system.

I

A detailed description of the Security menu and how to assign passwords can be found in the BIOS Setup documentation on the Fujitsu manuals server.

Preventing unauthorized system access

You can activate this protection by entering a system password in the Security menu.

Protecting BIOS from being overwritten

To activate this protection, select the value Disabled for the Flash Write field in the Security menu.

BX2580 M1

Operating Manual 63

Property and data protection

64 Operating Manual

BX2580 M1

8 Troubleshooting and tips

V

CAUTION!

Follow the safety instructions in the "Safety notes and regulations"

manual or " 安全上のご注意 " and in chapter "Important information" on page 29

.

If a fault occurs, attempt to resolve it using the measures described:

– in this chapter,

– in the documentation for the connected devices,

– in the help systems of the software used.

If you fail to correct the problem, proceed as follows:

Ê

Make a list of the steps performed and the circumstances that led to the fault.

Also make a list of any error messages that were displayed.

Ê

Switch off the server.

Ê

Contact our customer service team.

8.1

Server switches itself off

Server Management has detected an error

Ê

Check the Event Log of the management blade or – if ServerView

Operations Manager is installed – its error list or the ErrorLog file, and attempt to eliminate the error.

8.2

Screen remains blank

1

Monitor is switched off

Ê

Switch on your monitor.

Screen has gone blank

Ê

Press any key on the keyboard.

1

In the case of a monitor connected locally via the Y cable, see "Connecting devices" on page 44

.

BX2580 M1

Operating Manual 65

Troubleshooting and tips

or

Ê

Deactivate screen saver. Enter the appropriate password.

Brightness control is set to dark

Ê

Set the brightness control on the monitor to light. For detailed information, refer to the operating manual supplied with your monitor.

Power cable or monitor cable not connected

Ê

Switch off the monitor and the server.

Ê

Check whether the power cable is properly connected to the monitor and to the grounded socket.

Ê

Check whether the monitor cable is properly connected to the server and monitor (if it is plugged in with a connector).

Ê

Switch on the monitor and the server.

8.3

Flickering stripes on monitor screen

1

V

CAUTION!

Switch off the server immediately. Risk of damaging the server.

Monitor does not support the set horizontal frequency

Ê

Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê

Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

1

In the case of a monitor connected locally via the Y cable, see

"Connecting devices" on page 44 .

66 Operating Manual

BX2580 M1

Troubleshooting and tips

8.4

No screen display or display drifts

1

The wrong horizontal frequency or resolution has been selected for the monitor or for the application program.

Ê

Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê

Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

8.5

Incorrect date and time

Ê

Set the date and time in the operating system or in the BIOS Setup under the Main menu, using System Date and System Time respectively.

I

Note that the operating system may affect the system time. For example, the operating system time may deviate from the system time under

Linux, and would overwrite the system time in the default setting on shutdown.

If the date and time are still wrong after the server has been switched off and back on again, replace the lithium battery (for a description refer to the FUJITSU

Server PRIMERGY BX2580 M1 Server Blade Upgrade and Maintenance

Manual) or contact our customer service team.

8.6

System will not boot

The system will not boot after installing a new hard disk drive.

SATA configuration incorrect

Ê

Check the settings for the SATA configuration menu.

1

In the case of a monitor connected locally via the Y cable, see "Connecting devices" on page 44

.

BX2580 M1

Operating Manual 67

Troubleshooting and tips

Power budget limit value exceeded

Ê

Check whether the power budget limit value set in the management blade has been exceeded. You may need to install an additional power supply unit.

8.7

Hard disk drive error messages at system boot

Various hard disk drive error messages may appear when the system is rebooted. These error messages are caused by modifications in the selected

RAID configuration.

RAID controller configuration incorrect

Ê

Check and correct the settings for the drives using the RAID controller configuration program.

Further information can be found in the operating manual for the RAID controller.

8.8

Added drive reported as defective

RAID controller is not configured for this drive

The drive was probably installed when the system was switched off.

Ê

Reconfigure the RAID controller for the drive using the corresponding utility.

Information is provided in the documentation for the RAID controller.

8.9

Error message on screen

The meaning of the error message is explained in the documentation for the relevant components and programs on the Fujitsu manuals server.

68 Operating Manual

BX2580 M1

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement