3290 CLAMP ON AC/DC HiTESTER
2003
3290 CLAMP ON AC/DC HiTESTER
Field Measuring Instruments
All the Functions You Need for Measurement
at DC or 1Hz and Up
Choice of Three Sensors
Model
9691
Measurable
Maximum display
Measurement
conductor Rated input
range
Normal
measurement Peak measurement
diameter
25.00A
50.0A
20.00A
100Arms
φ 35mm
150Apeak
105.0A
150.0A
200.0A
9692
φ 33mm
200Arms
300Apeak
20.00A
25.00A
50.0A
200.0A
210.0A
300.0A
9693
φ 55mm
2000Arms
2840Apeak
200.0A
250.0A
500A
2000A
2100A
3000A
Choice of Measurement Methods
DC (for battery measurement)
AC + DC RMS (for full-/half-wave rectification
measurement)
AC RMS (for current distortion measurement)
PEAK (for peak value measurement of inrush
current, etc.)
φ 35mm
100 A
Choice of Outputs (simultaneous output)
● Frequency range:
DC to 10kHz (-3dB)
● Effect of conductor position:
less than +/-1.0%
● Effect of external magnetic fields:
equivalent to 0.5A or less (in a
400A/m external magnetic field)
● External dimensions:
approximately 53W(2.09")× 129
H(5.08")× 18D(0.71") mm
● Weight:
approximately 230g(8.1oz.)
Effective value output, frequency output, waveform
output
Choice of Response Times
Switchable among three measurement
response times
9691 Specifications
φ 33mm
200 A
LPF Function
9692 Specifications
● Frequency range:
DC to 20kHz (-3dB)
● Effect of conductor position:
less than +/-0.5%
● Effect of external magnetic fields:
equivalent to 0.7A or less (in a
400A/m external magnetic field)
● External dimensions:
approximately 62W(2.44")× 167
H(6.57")× 35D(1.38") mm
● Weight:
approximately 410g(14.5oz.)
Filters out unnecessary harmonics (fc = 500Hz)
* Cable can be extended to a maximum of 100m
(Special order)
Protected by dustproof cap!
φ 55mm
2000 A
9693 Specifications
Sensor Common Specifications
● Frequency range:
DC to 15kHz (-3dB)
● Effect of conductor position:
less than +/-0.7%
● Effect of external magnetic fields:
equivalent to 2A or less (in a
400A/m external magnetic field)
● External dimensions:
approximately 62W(2.44")× 196
H(7.72")× 35D(1.38") mm
● Weight:
approximately 500g(17.6oz.)
● Cable length: 2m(6.56 ft)
● Maximum circuit voltage: 600V
● Applicable standards: Safety: EN61010-2-032:1995, CAT III 600V, Pollution Class 2, EMC:
EN61326:1997+A1:1998+A2:2001
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - FAX 781.665.0780 - TestEquipmentDepot.com
Improved Measurement and Analysis Capabilities
for Low-frequency Current
Can also be housed in the 9400 CARRYING CASE
■ Can measure current from 1Hz and up - ideal for inverter motor control, etc.
The 3290 is capable of simultaneously recording the waveform and effective value of current for an inverter motor, etc. By being able to
record simultaneously with equipment control signals, the 3290 is also ideal for evaluation/analysis during product development and for
equipment maintenance.
* Capable of recording waveform and effective value simultaneously (MON & REC)
Control sign
al
recording
Effective value current recording
(REC)
Half-wave rectified waveform
while in operation (MON)
ent
Curr ding
r
reco
ompatible
PC card-c
r
e
record
Recording current consumption of a hair dryer
* Recording basic wave components while the 3290's filter function is on
Save data on a PC card in the field.
After returning to the office, data can be
analyzed and stored on a PC.
Accurate display of inrush current peak value
Display of maximum, minimum and average
values
3290 Specifications (Accuracy guaranteed at 23˚C ± 5˚C, 80%RH or less, with no condensation) ■ Period for which accuracy is guaranteed: 1 year
■ Included functions ● Zero adjustment (DC, AC + DC) ● Data hold ● Filter switching:500Hz LPF (AC, AC + DC) ● Recording functions: Displays maximum value
(MAX), minimum value (MIN), average value (AVE), elapsed time (TIME) ● Setting storage function: Settings can be stored ● Enlarged bar graph display( center zero at
DC mode) ● AC, DC separate outputs: MON output passed through a 1Hz LPF (OUT1 connector), AC coupled REC output (OUT2 connector at AC + DC A mode) ● Battery
consumption warning output: B.Lo setting of OUT2 connector (0V output for warning; normally 3.0V) ● Key lock ● Battery check ● Auto power off: Approximately 10
minutes after last key operation, preceded immediately by a beep ● Beep sound: On/Off
● Function display:
3290+9691, 9692 combined accuracy
Measurement frequency f
bar graph (21 segments), out of range
Mode
Range Response time setting
DC
1 ≤ f < 10Hz
10 ≤ f < 45Hz
45 ≤ f < 66Hz
66Hz < f ≤ 1kHz
(O.L.), battery consumption warning (B),
±1.3%rdg.±10dgt.
20.00A
hold (HOLD), auto power off (APS)
DC
● Measurement response time:
±1.3%rdg.±5dgt.
200.0A
(1) FAST (0.2 seconds)
: 45Hz or higher
FAST
±2.3% rdg.±8 dgt. (2) NORMAL (0.8 seconds): 10Hz or higher
±1.3% rdg. ±12 dgt.
(9691: up to
±1.3%rdg.±8dgt.
20.00A
NOMAL
(3) SLOW (8 seconds)
: 1Hz or higher
(when AC + DC is set only) ±2.0% rdg. ±8 dgt. ±1.3%rdg.±8dgt.
500Hz)
Input: Time for analog output value to stabilize
SLOW
(when AC + DC, SLOW is set only)
AC+DC
when changing from 0% → 90% or from 100%
AC RMS
FAST
±2.3% rdg. ±3 dgt. to 10%, AC (RMS) and AC + DC setting
±1.3% rdg. ±7 dgt.
(9691: up to
±1.3%rdg.±3dgt.
● Display update rate:
200.0A
NOMAL
(when AC + DC is set only) ±2.0% rdg. ±8 dgt. ±1.3%rdg.±3dgt.
500Hz)
(1) NORMAL
: approximately 2
(when AC + DC, SLOW is set only)
SLOW
times per second
±1.3%rdg.±8dgt. ±2.3%rdg.±8dgt.
20.00A
(2) SLOW
: approximately 1
AC MEAN
±1.3%rdg.±3dgt. ±2.3%rdg.±3dgt.
200.0A
time every 3
seconds
3290+9693 combined accuracy
Measurement frequency f
(3) FAST
: approximately 4
times per second
Mode
Range Response time setting
DC
1 ≤ f < 10Hz
10 ≤ f < 45Hz
45 ≤ f < 66Hz
66Hz < f ≤ 1kHz
(4) Bar graph display : approximately 4
±1.8%rdg.±10dgt.
200.0A
times per second
DC
±1.8%rdg.±5dgt.
2000A
● Zero suppress: 5 counts
● Range switching: Auto/manual
FAST
±1.8% rdg. ±12 dgt.
● Output update rate:
±1.3%rdg.±8dgt. ±2.3%rdg.±8dgt.
200.0A
NOMAL
(when AC + DC is set only) ±3.0% rdg. ±8 dgt. ±2.3%rdg.±8dgt.
(1) REC (A)
: DC2V/range
SLOW
(when AC + DC, SLOW is set only)
AC+DC
(2) REC (Hz)
: DC1V/range
AC RMS
FAST
(3) MON
: 2V/range
±1.8% rdg. ±7 dgt.
OUT1/OUT2 Combinations:
±1.3%rdg.±3dgt. ±2.3%rdg.±3dgt.
2000A
NOMAL
+
(when AC DC is set only) ±3.0% rdg. ±3 dgt. ±2.3%rdg.±3dgt.
MON/REC(A), REC(Hz)/REC(A),
SLOW
(when AC + DC, SLOW is set only)
REC(A)/B.Lo, MON/B.Lo, MON/B.Lo,
±1.3%rdg.±8dgt. ±2.3%rdg.±8dgt.
200.0A
MON.FL/B.Lo, MON.FL/REC(A)
AC MEAN
*fc=1Hz LPF(MON.FL)
±1.3%rdg.±3dgt. ±2.3%rdg.±3dgt.
2000A
Frequency range (accuracy range) Maximum display
10.00Hz (1.00 to 10.00Hz)
12.50Hz
100.0Hz (10.0 to 100.0Hz)
125.0Hz
1000Hz (100 to 1000Hz)
1000Hz
Accuracy
±0.3%rdg.±1dgt.
±1.0%rdg.±1dgt.
● Crest factor: 2.5 or less, or at or below peak value on connected sensor ● Output impedance: 100 Ω or less ●
Temperature characteristics: 0.1 × accuracy specification/˚C (at 0 to 40˚C) ● Operating temperature and
humidity range: 0 to 40˚C, 80%RH or less (with no condensation) ● Storage temperature range: -10 to 50˚C (with
no condensation) ● Locations for use: Indoors at altitudes up to 2000m ● Power supply: Four type 3 alkaline dry
cells (LR6) or AC adapter ● Maximum power consumption: 500mVA (when operating of batteries) ● Battery life:
approximately 22 hours (during continuous operation) ● Applicable safety standards: EMC: EN61010-1:2001,
EN61326:1997+A1:1998+A2:2001, EN61000-3-2:2000, EN61000-3-3:1995+A1:2001 ● External
dimensions/weight: approximately 155W(6.10")× 98H(3.86") ×47D(1.85") mm, approximately 545g(19.2oz.)
3290 CLAMP ON AC/DC HiTESTER
Option
(with strap)
9691
9692
9693
9445-02
9445-03
9094
9400
Measurement is not possible using only the 3290 CLAMP ON AC/DC HiTESTER
main unit. A CLAMP ON AC/DC SENSOR (sold separately) is also required.
● Example Combinations (Main Unit and Clamp Sensor)
3290 + 9691: Measure up to 100A
3290 + 9692: Measure up to 200A
3290 + 9693: Measure up to 2000A
CLAMP ON AC/DC SENSOR (100A)
CLAMP ON AC/DC SENSOR (200A)
CLAMP ON AC/DC SENSOR (2000A)
AC ADAPTER
AC ADAPTER (EU)
OUTPUT CORD
CARRYING CASE
3290E1-32M-05P
Printed in Japan
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - FAX 781.665.0780 - TestEquipmentDepot.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising