Series 940 Transmitter / Controller Specification Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Base Unit – – – Allows active sampling through a Teflon tube employing a vacuum pump Provides water ingress protection Allows remote sampling from inaccessible areas (eg. Controlled Atmosphere environments) – Improved performance in pressure and flow fluctuating environments Typical application Short distance remote monitoring for:Low Oxygen environments (3-5% O2) Indoor air quality – duct sampling Filtered air sampling Power (user supplied) 24VDC, 500mA (range 22-26 VDC) Analogue output 4-20 mA (opto-isolated), 12-24 V External signal type Transistor Output External signals 4 External signal functions Low Alarm, High Alarm, Control & Diagnostics LED Display (Optional) Inputs Standby toggle Communication RS485 Jumpers J1, J2, J3 termination resistors Connectors Screw 1 (Default) ID User configurable from 1 - 255 Alarm set points (2) User configurable Control set point User configurable RS485 protocol Aeroqual proprietary product Removable / replaceable sensor head Yes Sampling Pump 12VDC, long life, brushless, diaphram pump Enclosure rating IP41 & NEMA 2 equivalent Enclosure size 230W x 140H x 95D (mm); 9”W x 5½”H x 3¾”D (in) Enclosure casing Fibre reinforced polycarbonate Weight < 1100 g; < 1 lb 3 oz Approvals Part 15 of the FCC Rules EN 50082-1: 1997 EN 50081-1: 1992 Example: Series 940 Ozone Monitor (Format differs © Aeroqual Ltd, 2004 All rights reserved dependent on gas) Aeroqual Limited January 2005 Ozone Sensor Head Specifications Sensor Heads Low High Leak Measurement range Accuracy 0.000 - 0.500 ppm < 0.008 ppm (0 - 0.100 ppm) ± 10% (0.100 – 0.500 ppm) 0.001 ppm Available on Request 0.50 - 20.00 ppm ± 10% (0.20 - 2.00 ppm) ± 15% (2.00 - 20.00 ppm) 0.01 ppm Available on Request 0.00 - 50.00 ppm ± 20%, 15 seconds after Reset 0.01 ppm Available on Request Resolution Controlled Atmosphere Version T90 Response Sensor type Operating temperature range Relative humidity limit < 60 seconds (T90) < 35 seconds (T90) < 10 seconds Gas-sensitive semiconductor -5°C to 50°C; 23°F to 122°F (sensor head and base unit) 95% maximum (sensor head and base unit) VOC Sensor Head Specification* Measurement range 0 to 400 ppm toluene Accuracy < +/- 10 ppm (0 – 200 ppm) < +/- 10% ( > 200 ppm) T90 response < 60 s Sensor type Gas-sensitive semiconductor Operating temperature range -20°C to 60°C Operating relative humidity range 5 to 95% non-condensating * Specific Calibrations to other VOC’s available – contact Aeroqual Sales Ammonia Sensor Head Specification Measurement range 0 to 1000 ppm Accuracy < +/- 5 ppm (0 – 100 ppm) < +/- 10% (100 – 1000 ppm) T90 response < 60 s Sensor type Gas-sensitive semiconductor Operating temperature range -20°C to 60°C; Operating relative humidity range 5 to 95% non-condensating CO Sensor Head Specification Measurement range 0 to 2000 ppm carbon monoxide Accuracy < +/- 10 ppm in the range 0 to 400 ppm T90 response < 150s Sensor type Gas-sensitive semiconductor Operating temperature range 0°C to 70°C; Operating relative humidity range 5 to 95% non-condensating Approvals UL 2034, BS 7860 Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 © Aeroqual Ltd, 2004 All rights reserved Aeroqual Limited January 2005
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement