LCA 301
P
D
P
.
1
0
3
A
C
L fibus Manual
Pro
LCA 301
Appendix to the manual of
Reg 10212/0899
the LCA 300/320
Version 2/08.99
© Systeme Lauer GmbH & Co KG
Systeme Lauer GmbH & Co KG
Postfach 1465
D-72604 Nürtingen
Operator reference manual: LCA 301.PDP
Version:
12. August 1999
Person responsible:
Lackenbauer
Operating manuals, reference manuals, and software are protected by
copyright. All rights remain reserved. The copying, duplication, translation, conversion in the whole or into parts are not permitted. An exception applies to making a copy of the software for the own use.
•
We reserve the right to make changes to the reference manual without prior notice.
•
We can not guarantee the accuracy of the programs and data stored
on the diskette and the fault-free state of this information.
•
Since diskettes represent manipulatable data media, we can only
guarantee the physical completeness. The responsibility is limited
to a replacement.
•
At any time, we welcome suggestions for improvements and remarks
on errors.
•
The agreement also applies to the special appendices to this reference manual.
Microsoft, MS, MS DOS, Windows, Windows 95, Windows NT and the
Windows logo are either registered trademark or trademarks of the Microsoft Corporation in the USA and/or other countries.
SIMATIC and STEP are registered trademarks of the Siemens AG.
The remaining designations in this document can be brand names who’s
use by third parties for their purposes can violate the rights of the owners.
0-2
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
Suggestions for the user
Please read the reference manual before applying the unit first and store
the manual at a safe location for later use.
Target group
The reference manual is written for users with previous knowledge in
PC and automation technology.
Representation conventions
[KEY]
Key inputs of the user are represented in square
brackets, e.g. [CTRL] or [DEL]
Courier
Display outputs are printed in the Courier font, e.g.
C: \>
Courier bold
Keyboard input to be made by the user are given in
DIR
Courier bold, e.g. C:\>DIR
Kursiv
Names of buttons to be selected, menus or other
screen elements and product names are printed in
Italics.
Symbols The following symbols in the reference manual are used to
mark certain text sections:
Danger!
Possibly dangerous situation.
Injury to persons can be the result.
Attention!
Possibly dangerous situation.
Property damages can be the result.
Tips and supplementary notes
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
0-3
Table of contens
Suggestions for the user
0-3
Quality and support
0-5
Safety regulations
0-6
Standards
0-7
A
Siemens PLC
A-3
A.1 Basic data interchange .................................................... A-4
A.1.1 Determination of the configuration ................................. A-4
A.1.2 Configuration of the master card (S5) ............................. A-5
A.1.3 Configuration of the L2-DP network (S7) ........................ A-8
A.1.4 Structuring a master system ............................................ A-9
A.2 Commissioning ............................................................. A-12
A.2.1 Parameterization of the LCA 3xx.p ................................ A-13
A.2.2 Set-up and first powering up ......................................... A-14
A.2.3 Demo project ................................................................ A-14
A.2.4 Trouble-shooting ........................................................... A-15
A.2.5 Communication processing ........................................... A-16
A3. Specifications ................................................................ A-17
B
Bosch PLC
A-3
B.1 Profibus connection to Bosch PLCs .................................. A-3
B.1.1 Configuration of the (DESI-DP) master card .................... A-4
B.1.2 Hardware settings using the DESI-DP card as an example A-5
B.1.3 “LCADP” handling software ............................................ A-7
B.2 Commissioning ............................................................... A-8
B.2.1 Trouble-shooting ............................................................. A-8
B.2.2 Handling software printout ........................................... A-10
Index
0-4
i-1
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
Quality and support
In our company, quality comes first. From the electronics component
up to the finished device, the quality assurance tests competently and
comprehensively.
National and international test standards (ISO, TÜV, Germanischer Lloyd)
are the basis.
Within 48 hours, every device passes a 100% check and continuous test
under worst case conditions at changing temperatures (0... 50°C) and
test voltages.
A guarantee for maximum quality.
Our products not only feature a maximum economic efficiency and
reliability but also a comprehensive complete service.
You not only receive demo devices but we rather make specialists available
who support you in person with your first application.
Qualified user consultation by competent sales engineers is obvious for
us.
Our support is for you for the side with advice and deed every day.
We set up training programs and technical training for you in our modern training center or alternatively also in your house.
Request the current training catalog.
From the consultation up to the user support, from the hotline up to
the service, from the reference manual up to the training an all covering
and individual service for the entire product line is waiting for you.
Whenever you need us, we are there for you:
dynamically, creatively and enormously efficiently. With the entire
experience of a world-wide successful enterprise.
Telephone
eMail:
Web site:
07022/9660 -222, -132, -231, -230
[email protected]
www.systeme-lauer.de
Systeme Lauer Active Area
(Download of Software, driver, manuals, Forum ...)
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
0-5
Safety regulations
This reference manual contains the most important remarks in order to
safely operate the device.
0-6
•
This operator’s guide, particularly the safety remarks are to be noted
by all persons working with the device.
•
Furthermore, the rules and regulations for the accident prevention
applying to the application location are to be observed.
•
Use as directed. The device is designed for the application in the
industrial area.
•
The device is manufactured to the state of the art and the official
safeguarding regulations. Nevertheless, due to the application,
dangers or impairments can result to the machine or to material
assets.
•
The device meets the requirements of the EMC guidelines and
harmonized European standards. Any hardware-related modification
of the system can influence the EMC behavior.
•
The device may not be used without special protective measures in
the hazardous area and in plants requiring a special monitoring.
•
Do not heat up the buffer batteries. Danger of explosion. Serious
burnings can be the result.
•
The installation and operation may only be performed by trained
personnel.
•
The operating voltage of the device may only be in the specified
ranges.
•
You find information on this on the type plate and in the specifications of this reference manual.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
Standards
The PCS is manufactured to the state of the art and meets the requirements of following guidelines and standards:
•
EMC guideline 89/336/ EEC
•
EMC specialist basic standard EN50081 part 2 Noise Emission in
The Industrial Area
•
EMC specialist basic standard EN50082 part 2 Interference Resistance
in The Industrial Area
•
European Extra Low Voltage Guideline 73/23/EEC
The mounting and connection instructions described in this documentation are to be observed.
The conformity is confirmed by attaching the CE sign.
The EC conformity declarations can be asked for at:
Systeme Lauer GmbH & Co KG
P.O. Box 1465
D-72604 Nürtingen
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
0-7
0-8
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
A.
Siemens PLC
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-1
A
A-2
Siemens PLC
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
Contents of this manual
This manual relates exclusively to the use of the LCA 300.p or LCA 320.p
Profibus-DP slave operating console (in the following designated as LCA
3xx.p) together with the LCAL2PST.S5D, LCAL2QST. S5D, LCAL2EST.S5D
and/or LCAS7x.AWL programmable controller handling software.
The network setup was tested with a S5-115U (CPU 942, 943, 944,
945) and a S5-135U (CPU 928) together with a S5-DP IM308B master
card (version 6), an IM308C (version 2), a CP5431 (version 3) and a
S5-95U 8ME01/2 output. Together with a S7, the set-up was tested
with a CPU 315-2 DP. In the following, the commissioning is described
for this set-up.
The LCA driver is based on the Siemens SPC3 chip with Siemens object
codes. Systeme Lauer can assume no responsibility for errors in and
limitations due to the functionality of the Siemens software.
The programming of the Siemens programmable controllers, the Profibus master cards and the basic Profibus-DP functions are assumed as to
be known.
Which parts do I need?
The following products are required for a Profibus-DP network set-up
(Systeme Lauer):
•
LCA 3xx.p Profibus operating console.
•
The LCAPRO configuration software and an LCA 733 programming
cable.
•
The LCA 301.PDP driver manual including LCA 301.SIE floppy disk.
The following products are required for a Profibus-DP network set-up
(Siemens):
•
A S5 or a S7-300 (406) programmable controller with Profibus-DP
master.
•
A Profibus-DP master plug-in card (only for S5), version IM308B
(version 6), IM308C (version 2) CP5431 or S5-95U (8ME01 Rev.2).
•
Programming software for the programmable controller and the
master card.
•
Profibus-DP network cable and bus connection connectors.
.... as well as power supplies for all components.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-3
A
Siemens PLC
A.1 Basic data inter
change
interchange
The communication link is established between the LCA and the programmable controller data area via the following communication partners:
LCA operating console
t
Profibus master
t
PLC (LCA DB)
t
Profibus master
t
LCA operating console
LCA operating console
The LCA operating console determines the tasks to be executed (based
on the enables, the display contents and the keys). The console sends
these in a package to the Profibus master.
The master card stores the package in the input area of the programmable
controller.
PLC
•
The communication data block reserving 132 words (e.g. DB50) is
located in the programmable controller.
•
The task input buffer is located in an input area of the programmable
controller.
•
The task response buffer is located in an output area of the programmable controller.
•
A cyclically selected handling block executes the tasks in the input
buffer on the data block and stores the answer in the output buffer.
The master card retrieves the answer package from the output area of
the programmable controller and submits it to the slave.
The LCA operating console evaluates the data and displays the answer
in the display.
The inquiry/answer package is provided with an order number so that
the answer always matches the inquiry.
A.1.1
Determination of the configuration
A.1.1Determination
Everywhere, the settings must correspond for all parts working correctly
together!
Master card
With the configuration of the master card, you determine the Profibus-DP
network.
The following fixed settings apply for a LCA 3xx.p slave:
•
8 bytes for the input buffer and 8 bytes for the output buffer
A.1.2
Configuration of the master card (S5)
A.1.2Configuration
A-4
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
You determine the settings of the Profibus-DP network in the COM ET
200 software. The data length of every slave must be defined there too.
IM308B
Version 6
To be able to define the LCA 3xx.p slave operating console, the “LASPC3
TD.200” file of the LCA 301.SIE floppy disk must be copied (README.TXT
consider) to the COM ET 200 directory.
Take care that under DOS “LASTDRIVE” is set to “Z” before executing
the software.
IM308C
Version 2 or higher
Copy the “LAUSPC3X.200” type data into the “Typdat5x” subdirectory.
CP5431
Set the slave interval times manually in the DP editor (values follow on
the next pages).
IM308B
Now, select the COM ET200 software for an IM308B (version 6)...
ET200 parameter
•
The baud rate should be in the range of 187.5 and 1500 Kbaud.
•
The bus profile must be selected as “Standard Profibus-DP”.
•
The correct CPU type must be selected.
•
No diagnosis is required.
Configuration parameter
•
Here, you determine the slave parameters.
•
Select the parameter file: “Lauer DP slave 5” for IM308B,
•
Set the consistency to “0”.
•
For each slave, you should define 8...32 input bytes and 8..32 output
bytes.
IM308C
For an IM308C, select the COMWIN10 software...
Bus parameters
Select Profibus-DP.
Host parameters
Select the used CPU type.
Master parameters
•
Station type: IM308C
•
Addressing type:
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-5
A
Siemens PLC
You can select in the linear area of the P or Q area. The P or Q tiles
are possible in the tile area. Then, select the number of the IM308C
(0/16/32/48). Each IM308C can manage 16 tiles.
•
Error message mode:
Can be set to QVZ (acknowledgment delay on error).
Attention with acknowledgement delay!
If during running-up, the LCA slave is not interfaced to the network
then it is not linked to the network at a later point in time. Therefore,
load the LCA correctly before you interface it to the Profibus network!
Without acknowledgement delay, a correct DP slave is linked to the
network at any time!
Slave parameters
Transfer
•
Access monitoring: on
•
Select the “PCS_LCA with SPC3” type file.
•
In the linear area, you can select P000-P255 and/or Q000-Q255.
•
In the P tile area, 0P192-15P255 is possible.
•
In the Q tile area, 0Q0-15Q254 is possible.
•
Enter 8 input bytes and 8 output bytes for each LCA slave.
•
Sync or Freeze is not necessary.
•
Activate the board consistency.
Now, program the EPROM cassette or the Flash module and plug it into
your IM308 board.
Note the I/O address for programming the programmable controller
controller..
CP5431
Call the SINEC.NCM (version 4.6) for a CP5431.
In contrast to the IM308 board, the CP5431 sends no configuration
telegram. Thus, the settings on the board and on the LCA 3xx.p must
correspond. Ensure that the DP is set to 8 input bytes and 8 output
bytes.
The Profibus DP function may only be combined with asynchronous
FMS services!
Use only the I/O area of bytes 0...127 in the 115U CPU 941-943 programmable controllers. Otherwise, inconsistencies can appear.
Please consider the following settings:
•
A-6
CP init:
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
Network file: NETWORK2NCM.NET
•
Network parameters:
Default SAP: 61
•
Peripheral I/O area:
DP update: cycle synchronized
Fill in the ZI/DP start (even) and ZI/DP end (odd) input and output
areas.
•
Peripheral/DP slave parameterizing:
Manufacturer ID: 0008
Sync mode: off
Freeze mode: off
•
Peripheral/DP editor
Global data:
Largest min. slave interval: 2 x 1 ms
Min. poll scan time: 1 x 10 ms
Access monitoring time: 20 x 10 ms
Set the interface correspondingly. Perform a network adjustment
with the “NETWORK2NCM.NET” file and transfer your data base
file into the CP5431.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-7
A
Siemens PLC
A.1.3
Configuration of the L2-DP network (S7)
A.1.3Configuration
Sinec L2-DP network
A Sinec L2-DP network consists of DP master and DP slaves that are
connected by a bus cable and communicate with each other via the DP
protocol (remote peripheral).
DP master
As DP master you can insert:
DP slaves
•
a CPU with fixed built-in or pluggable DP master interface (fixed
built-in, e.g. CPU 315-2 DP)
•
an interface module that is associated to a CPU/FM (e.g. IF 964-DP
in CPU 488-4)
•
a CP together with a CPU (e.g. CP 342-5: this is parameterized with
a special software that is called in STEP 7).
As DP slaves you can insert:
•
boards with built-in digital/analog I/O channels (compact DP slaves,
e.g. ET 200B, PCS 807 or LCA 3xx.p)
•
interfacing modules with associated S5 or S7 modules (modular DP
slaves, e.g. ET 200M).
Procedure
Basically, you configure a SINEC L2-DP network just as in a central set-up.
Go ahead as follows:
Assign DP master in configuration table of the local module rack
Assign DP master to a SINEC L2-DP network and allocate L2 adress
(Create master)
for modular DP slave:
for compact DP slave:
Assign DP slave in configuration table and allocate L2 adress
assign the designation to the DP slave
assign I/Q addresses
to the module designations
assign I/Q addresses
to the DP slave
Save the configuration
Mapping in the configuration table Assign the DP master centrally to a rack. Allocate the DP slaves to an
own configuration table. Switching to this configuration table is performed only if you have configured the DP master.
A-8
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
A.1.4
Structuring a master system
A.1.4Structuring
•
Requirement
You have selected the configuration table.
•
Master system
All DP slaves that are associated to a DP master form a master system
along with the DP master. A master system is part of a SINEC L2-DP
network.
•
Creating a master system
Create the relevant master system after you have arranged the DP
master in the configuration table.
Creating a master system means that you associate the DP master
to a SINEC L2-DP network and assign an L2 address to the DP master.
•
Select and arrange a DP master
Select a DP master from the board catalog and assign it to the
configuration table.
Result:
if the DP master is a built-in interface on a CPU, then a “+” is displayed on the left side of the CPU. A second line is displayed with
the DP master if you click onto it.
Further procedure:
If you have arranged the DP master in the configuration table then can
you either:
•
continue with the allocation of “central” boards in the configuration
table or,
•
continue to configure the SINEC L2-DP network by associating the
DP master to a SINEC L2-DP network and assign it an L2 address.
•
L2 address
You must assign an L2 address to each DP master and DP slave of a
master system for the clear identification in the SINEC L2-DP
network.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-9
A
Siemens PLC
•
Network assignment and L2 address assignment
Go ahead for the network assignment and L2 address assignment
as follows:
1.
Mark the line in which the DP master is located.
2.
Select the EDIT ä Master system ä Open menu command. A dialog
field for the network and L2 address assignment is displayed.
3.
Assign the DP master to a SINEC L2-DP network to (a default network
is offered).
4.
Assign an L2 address to the DP master (the lowest free L2 address is
offered as default value).
Result:
the “Master system configuration table” is displayed after the assignment of the SINEC L2-DP network and the L2 address.
•
Master system configuration table
In the master system configuration table, arrange all DP slaves of a
master system and parameterize them.
•
Select and arrange a DP slave
Go ahead as follows to arrange a DP slave in the configuration
table:
1.
You must make the type file available:
• From the PCS 91.SIE floppy disk, copy the LAUSPC3X.200
file into your STEP7\ S7DATA \TYPDATEI directory. Open
the configuration table. Call the Extra ä Update type files
menu command. Close your application now and restart
STEP 7. The type file is now entered in the hardware catalog.
2.
From the hardware catalog, select the PCS_LCA DP slave with
SPC3 (you find it under ProfibusDP\Normslave\Siemens).
3.
Arrange the DP slave in the configuration table.
STEP 7 automatically presents a list field with free L2 addresses.
The next free L2 address is proposed to you as default value.
4.
A-10
Assign the L2 address.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
•
Associate boards to the modular DP slave
Go ahead just as if you arrange boards in a local configuration to
associate boards to a modular DP slave. Please take note that the
DP slave must be opened before you can associate boards (click
onto “+”).
Now, insert 2 default modules.
•
Assign identifications to the modular DP slave
Identifications are assigned to modular DP slaves. In the DP ID, the
characteristics (like address ranges and data consistency) of the
boards are encoded.
The DP ID appears automatically if you insert the board into the
configuration table. You can edit the DP ID by double-clicking onto
the DP ID line.
•
Assigning I/O addresses
Each I/O of a DP slave is associated exactly one address that is used
to address the input/output. Therefore, you must assign a start
address to each board/DP ID of a DP slave.
STEP 7 automatically assigns default addresses when you insert the
board/the DP slave in the configuration table. The default addresses
and their length are entered into the “I ADR.” and/or “OADR.” and
“Length” columns.
Enter 8 input and 8 output bytes for each slave.
Tip!
Note the I/O addresses for programming the programmable controller!
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-11
A
Siemens PLC
A.2 Commissioning
In the following, “FC” is valid instead of “FB” for a S7 application.
You find the “README.TXT” file in the ROOT directory of the LCA 301.PRF
floppy disk. There, the relevant handling block is described for each
project. For a first test of the connection, load the handling block for
the Profibus-DP project into the programmable controller. It is LCAL2
PST.S5D for the P area, LCAL2QST. S5D for the Q area, LCAL2
EST.S5D for the I/O area and LCAS7x.AWL of a S7. With a S7, load the
mnemonic list file as S0 object (source) and compile it. Edit the FB201
and FB202 (S7: FC 101 and FC 102) and adjust the assignment to the
used LCA. Remove the stop command! The LCA data block must be
created or loaded into the start OB.
For each LCA 3xx.p slave operating console, link a call of the FB203
handling block (“LCAPROFP” for the P area and “LCAPROFQ” for the Q
area) and “LCAPROFE” for the I/O area in your programmable controller
program. Link the FC 103 for the S7. Set the P or Q tile if you use these
before calling the FB203. With these call parameter you determine:
A-12
•
UBDB
the name of the data block, e.g. DB50
•
RXF
A
RXFA
the location of the input buffer (like master card), e.g. KF +40 (S7:
location of the inputs)
•
TXF
A
TXFA
the location of the output buffer (like master card), e.g. KF +50 (S7:
location of the outputs)
•
RSET
the restart input, e.g. E0.0
•
TIMT
the name of the time-out timer, e.g. T5
•
TIMZ
the time-out time, e.g. KT 20.1 = 2 seconds (S7: S5T’ 2s)
•
RFLM
the first scan flag, e.g. M10.0
•
EROR
the error flag, e.g. A0.0
•
COFF
the error block, e.g. FB202 (S7: FC 102)
•
INIT
the first initialization block, e.g. FB201 (S7: FC 101)
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
Thus, the example is set to the following values:
•
The input buffer is located from PY40 to PY47 or QB40 to QB47.
•
The output buffer is located from PY50 to PY57 or QB50 to QB57.
•
The time-out timer is timer T5 with a value of 2 seconds.
•
The restart input is assigned to E0.0
•
The error output is assigned to A0.0
•
FB201 is selected in the first scan.
•
FB202 is selected only once for each communication loss.
A.2.1
Parameterization of the LCA 3xx.p
A.2.1Parameterization
During the configuration of the LCA, both the application program with
data and a selected driver are transferred. The settings of the driver
variables can be changed.
Variable time-out
The time-out time to be set is the time that the programmable controller
needs at maximum to cyclical call the LCAPROFX communication program plus the communication time. The time is adjustable between 0.5
and 4 seconds - default is 1 second.
Variable LCA station number
This corresponds to the Profibus DP slave number. Therefore, it may be
selected between 3 and 126. The default value is 3. This value is taken
over during the powering up of the LCA. The LCA firmware must be
transferred new for changing this value.
Transfer of the data record into the LCA
1.
Apply operating voltage (19..33V) to the LCA. The COM-LED lights
now.
2.
Connect the programming interface of the PC to the LCA operating
console using the LCA 733 programming cable.
3.
Run the LCAPRO configuration software.
4.
In the start selection, select the Siemens/Profibus driver
5.
Create or load your data file.
6.
Set the driver parameters under the Project and Drivers menu items.
Basically, you can take over the default settings.
7.
Transfer the compiled data record into the LCA.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-13
A
Siemens PLC
A.2.2
Set-up and first powering up
A.2.2Set-up
Set up the configuration when you have configured all parts. Thereby,
the following points should be considered:
•
Profibus-DP network
Use only suited cable for wiring.
The last participant in the Profibus-DP network must have a
terminator connected. Use the Siemens “SINEC L” bus connectors
for this. Special bus connectors are required (Siemens order no.:
6ES7 972-0BA10-0XA0) for baud rates between 3 and 12MBaud.
For the LCA 320.p, also the Lauer terminals can be used instead of
the Siemens bus connectors but only up to a maximum baud rate
of 500 KBaud. You have to use the Siemens bus connectors in case
you need a cable terminator. Connect the red cable to “A”, the
green cable to “B” and the cable screen to the screen symbol. Take
care to use a cable strain relief (not for the LCA casing).
•
Profibus master card
Search the correct slot for your board. Otherwise, the board may
be damaged.
•
Mechanical mounting of the LCA 3xx.p operating console
The LCA 320.p operating console must be grounded!
You can commission the components now in two steps:
Step 1:
Network
•
Set up the Profibus-DP network.
•
Power up the programmable controller and the LCA 320.p operating
console.
•
Now, the IM308 “RN” LED lights and the “BF” LED flashes.
•
After 5 seconds the latest the “BF” LED of the master card is
deactivated and the green “Profibus COM”-LED on the rear panel
of the LCA operating console lights statically.
•
With the S7, the “SF-DP” and “BUSF” LEDs are deactivated.
Step 2:
Logical communication
•
Set the restart input of the programmable controller to “ON” or
switch the programmable controller from STOP to RUN.
•
The red “ERR” LED on the LCA front panel is deactivated after 2
seconds the latest.
A.2.3
Demo project
A.2.3Demo
A demo project for an IM308C is provided on the Siemens floppy disk
to enable a simple entry into the Profibus-DP configuration. In this
example a Profibus-DP network with an LCA operating console for the
linear P area (bytes 0..7) is prepared. The commissioning procedure is
exactly documented in the enclosed README.DOC file.
A-14
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
A.2.4
Trouble-shooting
A.2.4T
PLC enters the STOP mode
•
The stop commands in the handling software were not yet removed.
Please remove those.
•
Programmable controller STOP (QVZ) is set on Profibus-DP errors
in the master configuration. Get the network running.
•
The configuration of the master card is not compatible to the programmable controller. Please correct.
•
IM308 does not enter the RUN mode or flashes.
•
Wrong slot for the IM308. Please correct.
•
Configuration data incorrect, not programmed or EPROM or Flash
module is missing. Examine your data and the cassette.
PLC in RUN mode, the “BF” LED of the IM308 (S7: “BUSF” LED) flashes
for more than 10 seconds
•
Fault in the network configuration. Please correct.
•
LCA operating console not ready because:
Incorrectly connected. Please correct.
•
LCA jumper on “Prog” (test operation and forced loading). Set
jumper to “Auto”.
•
Not switch on. Apply 24V 10% supply voltage to the operating
console.
•
Wrong slave number. Set the slave number correctly and transfer
project again into the LCA.
PLC in RUN mode, the “BF” LED of the IM308 (S7: “BUSF” LED) is OFF
OFF,,
the LCA “ERR” LED is ON
•
In the programmable controller, the Profibus block is not executed.
Please link.
•
FB203 configuration is different to the master card or the LCA. Please
check and correct if necessary.
•
Time-out timer expired. Set restart input = 0. (UEROR:=RSET)
•
A wrong driver was loaded into the LCA operating console. Transfer the correct driver together with the data record again into the
LCA operating console.
PLC in RUN mode, the “BF” LED of the IM308 (S7: “BUSF” LED) is OFF
OFF,,
the LCA “ERR” LED is OFF but later ON again.
•
The communication runs of course (LCA “ERR” LED is deactivated)
but after a certain time the “ERR” LED starts to flash. This points
out that the communication functions of course but a monitoring
condition such as Time-out was not observed. Possibly, the restart
input is also not set or the handling block is selected irregularly.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-15
A
Siemens PLC
A.2.5
Communication processing
A.2.5Communication
LCA 3xx.p operating console Profibus-DP
The LCA 3xx.p operating console driver software is based on the object
codes of the Siemens company. In addition, serial communication and
logical evaluation was added.
During the first scan, the slave number set in the driver parameters is
taken over. The firmware can then be interfaced to the Profibus-DP
network as independent slave.
Set-up of the logical communication
The Profibus-DP communication uses the Siemens I/O area. Depending
on the programmable controller, the size is between 128 bytes and
several Kbytes (tiling). A Profibus-DP master must be available in the
programmable controller for the communication.
The configuration of the slave operating console is determined in the
master card. If a wrong configuration is submitted to the LCA then the
Profibus configuration (not CP5431) runs of course but there will be no
logical data interchange.
The driver in the LCA operating console splits the occurring tasks in part
tasks. Together with an order number, each part task is enclosed in a
package. This package is stored in the I area of the programmable
controller. A programmable controller expander program reads the
package and applies the contained instruction to a DB. The result is
stored in the O area with an inversed order number. From there it is
submitted to the LCA operating console.
Tip!
For the LCA DB please take note that the useful data area only starts at
DW4! Thus, the LCA byte 0,1 is located in DW4, LCA byte 8,9 is located
in DW8, etc.
Currently, the realized transfer time is approx. 30 ms per task package.
Since the reading of the LCA area is distributed across several transfers,
an area reading time of approx. 300 ms is reached. However, a key will
be transfer within 30 ms! Therefore, with an only shortly pressed key,
the releasing of a key can appear before the “LED read” task which
results in a non-display of the LED.
Visual control
•
Green “Profibus communication” LED on the rear panel. The LED is
OFF with no active communication. The LED flashes if a baud rate
was recognized. The LED is ON with a data interchange taking place
on the Profibus network.
•
Red “Communication” LED on the LCA front panel. This LED is OFF
with the logical communication being active.
Optimal configuration
The tasks of the LCA operating console depend on the display content.
Avoid gaps in the variables and message area. Allocate the variables
directly after the message area.
A-16
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A
Siemens PLC
A.3 Specifications
Description
•
LCA 300.p or LCA 320.p Profibus-DP slave operating console
System requirements
•
Profibus-DP standard network according to DIN 19245
System assignments
•
8 bytes in the input area of the PLC
8 bytes in the output area of the PLC
Additional interface
•
9-pin JD connector with RS-485 interface for Profibus connection
Additional displays
•
1 green LED for the Profibus communication state
TIP!
All other specifications correspond to the specifications in the LCA 300/
320 manual.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
A-17
A
A-18
Siemens PLC
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
A.
Bosch PLC
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-1
B
B-2
Bosch PLC
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
B.1 Profibus connection to Bosch PLCs (using the CL 400 as an example)
This section relates exclusively to the use the LCA3X0.P Profibus-DP
together with the SIEL2DME PCS driver and the Lauer Profibus handling
software.
The network configuration was tested with all LCA types, a ZS400-CPU
and a DESI-DP master card. In the following, the commissioning of this
set-up is described.
The LCA3X0.P is based on the Siemens SPC2/SPC3 chip with Siemens
object code. Systeme Lauer can assume no responsibility for errors in
and limitations due to the functionality of the Siemens software.
The programming of the Bosch programmable controllers and the Profibus master cards as well as the basic Profibus-DP functions are assumed
as known.
Which parts do I need?
The following products are required for a Profibus-DP network set-up
(Systeme Lauer):
•
LCA 3X0.P.
•
The LCAPRO configuration software and a PCS 733 programming
cable for the LCA text display.
•
The LCA 301.PDP manual including the PCS 91.BOS floppy disk.
The following products are required for a Profibus-DP network set-up
(Bosch):
•
A CL400 programmable controller.
•
A Profibus DESI-DP or DESI-DP12 master card.
•
Programming software for programmable controller and master
card.
•
Profibus-network cable and bus connectors.
... as well as power supplies for all components.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-3
B
Bosch PLC
B.1.1
Configuration of the ((DESI-DP)
DESI-DP) master card
B.1.1Configuration
Everywhere, the settings must correspond for all parts working correctly
together!
Type file
Copy the “LAUERDP.GSD” file into your BOSCH.BIB directory.
This file is required for the master file to be created and contains the
configuration functions of the LCA 3X0.P slave.
Now, run the Profi software of the master card. Select the DP software
with F3. Create a new project or use the supplied LCADP project.
Select the editor with F2. In the BTN overview, select the PCS 807 type.
Select the configuration matching your application under the Modules
group. (Length of the transfer buffer in bytes). Specify the slave address
of the LCA.
Now, change to the BTN DETAIL window with F5. Enter the desired
input and output bytes for the communication.
Note!
The fixed number of I/O bytes needed for the communication totals 8
bytes respectively.
You can use also the extended inputs and outputs. Make sure that they
are in an ascending order. Otherwise, the handling block does not understand the communication commands.
For the data interchange, the DESI-DP master card requires link a buffer
of 6 bytes in size. Set the start address of the link buffer in the Bus
master settings menu.
Load the master file into the master card. Take note, that the set baud
rate of the software and the set baud rate of the master card match.
Note!
Note the set size of the inputs and outputs, their start addresses and all
other settings. The specifications are required for the handling block or
for the DIL-switch settings of the master card.
B-4
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
B.1.2
Hardware settings using the DESI-DP card as an example
B.1.2Hardware
Note!
See also the Bosch DESI-DP Bus master manual.
•
Settings the link address with the S4 DIL-switch:
Switch 1 of S4 is used for selecting the address range.
•
ON
I/O-area
•
OFF
IZ/OZ-area
The other switches of S4 are used for setting the start address, refer to
the following figure.
Valence:
I/O
21
22
23
Example:
Coupling address: EZ/AZ
Example:
Coupling address: I/O 4
24
25
26
27
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-5
B
Bosch PLC
You set the desired transmission rate with the S5 DIL-switch. The PCS
807 slave module is thereby adjusted automatically.
Baud rate
Switches
[kBaud]
1
2
3
4
9,6
OFF
OFF
OFF
OFF
19,2
ON
OFF
OFF
OFF
93,75
OFF
ON
OFF
OFF
187,5
ON
ON
OFF
OFF
500
OFF
OFF
ON
OFF
1500
OFF
ON
ON
OFF
All DIL-switches of S3 are set to OFF in the test configuration.
Note!
Possibly other settings are required by other boards (see DESI-DP12) for
the master station address. Please refer to the corresponding manuals
of the master card.
B-6
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
B.1.3
“LCADP” handling software
B.1.3“
For the evaluation of the received data, the “LCA_KOMM” block is
required for performing the data exchange with the LCA DB. Furthermore, an initialization block (INIT) and an error block (COFF) are provided. In this block you can define the data word default assignments or
the emergency assignments. Furthermore, an OB1 example is provided
in which the call of the block is implemented. The files are stored on the
PCS 091.BOS floppy disk in the Profibus directory.
Note!
In the OB1, the first input word of the master link buffer must be specified
as the first output word of the link buffer. This is required for the CPU-DP
master synchronization.
Parameters of the LCA_KOMM block:
The block requires 12 parameters. This enables the free choice of the
addressing.
In OB1, you find an example (refer to the handling software print-out).
The meaning of the parameters is as follows:
P0:
PCS user DB. (256 words for PCS data)
P1:
Start address of the selected Profibus input bytes
P2:
Start address of the selected Profibus output bytes
P3:
Restart input or reset flag - required for restarting the communication after a communication fault
(Set the input to permanently high for an automatic restart)
P4:
Timer for time-out monitoring
P5:
Timer time as constant
P6:
Communication error output (after a communication fault, the
output is set to high)
P7:
PB of the “INIT” block
P8:
PB of the “COFF” block
P9:
Required flag (freely selectable, may not be used by other program parts)
P10: Required flag (freely selectable, may not be used by other program parts)
P11: Required flag (freely selectable, may not be used by other program parts)
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-7
B
Bosch PLC
B.2 Commissioning
Set up the configuration when you have configured all parts (without
voltage being applied).
Thereby, the following points should be considered:
•
Use only suited cable for wiring.
•
The last participant in the Profibus-DP network must have a terminator connected. Special bus connectors are required.
Go ahead as follows for powering up:
•
Power up the programmable controller and the LCA 3X0.P.
•
After 5 seconds the latest the “SEND” LED of the master card is
activated and the green “ COM” LED of the LCA 3X0.P operating
console lights statically.
•
Set the restart input of the programmable controller to “ON” or
switch the programmable controller from STOP to RUN mode.
•
The red “ERR” LED of the LCA is deactivated after 2 seconds the
latest.
B.2.1
Trouble-shooting
B.2.1T
PLC enters the STOP mode
•
The stop commands in the handling software were not yet removed.
Please remove.
•
Configuration of the master card is not compatible to the programmable controller. Please correct.
PLC is in RUN mode, “SEND” LED is OFF
•
Fault in the network configuration
•
Multibox not ready - caused by:
wrong slave address, check whether master file corresponds to the
address.
an “in reset state” condition (DIL-switch 10 is set to ON), set switch
DIL 10 to OFF.
no supply voltage - provide the Multibox with voltage.
B-8
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
PLC in RUN mode, “SEND” LED is ON, status message 01
•
Programmable controller in STOP mode, switch the programmable
controller to the RUN mode
•
Network fault, ascertain that all participants are correctly configured.
Check the communications cable.
•
Link error (CPU is not synchronized with master card), ensure that
the start input word of your selected link buffer is cyclically copied
to the start output word.
PLC in RUN mode, “SEND” LED is ON, no status message, LCA “ERR”
LED is ON.
•
The Lauer handling block is not selected in the programmable
controller. Please link with correct parameters.
•
A wrong driver was loaded into the LCA. Transfer the data record
with the correct driver again into the LCA text display.
PLC in RUN mode, “SEND” LED is ON, no status message, “ERR” LED is
OFF but later ON again.
•
The network configuration was not synchronized with all participants. Switch off all involved devices. Restart all devices.
•
The network set-up is located in a noisy environment. Take appropriate measures.
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-9
B
Bosch PLC
B.2.2
Handling software printout
B.2.2Handling
Table
B1
PB4
PB2
PB3
of contents
OB1
LCA_KOMM
INIT
COFF
Master block
Expander program for LCA
Initialization block
Error block
;**************************************************************************
;
OB1
;**************************************************************************
; Filename: OB1
; Function: Organisationsbaustein
;**************************************************************************
;
P r o g r a m
;**************************************************************************
L
W
EZ64,A
; copy the first word of your I/O-Area of the
T
W
A,AZ64
; CPU - DESI-DP coomunication from input to
; to output
;*** call the Lauer communication subroutine PB4 ( LCA_KOMM )
BA
P0
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
W
W
W
B
W
W
B
W
W
B
B
B
PB4,12
DB1
&EZ10
&AZ10
E0.3
T1
K4.2
M100.0
PB2
PB3
M100.2
M100.3
M100.4
;U
;=
B
B
M100.0
A3.7
PE
B-10
;
;
;
;
;
;
;
;
call expander program
DB LCA-datafield of 132 words
startadress of the Profibus-Input (8 bytes)
startadress of the Profibus-Output (8 bytes)
B
restart input
T
Watch-Dog LCA communication
K
timevalue for „watch dog“
B
output-bit communication error
; PB INIT (communication init LCA)
; PB COFF (communication error LCA)
; B
for internal use
; B
for internal use
; B
for internal use
; communication error to output
;program end
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
;**************************************************************************
;
LCAKOMM
;
expander-program for communication via Profibus with LCA STARLINE
;**************************************************************************
; Filename: LCA_KOMM
; function: expander for the Cl400
;
;
;**************************************************************************
;
D e c l a r a t i o n
;**************************************************************************
; subroutine parameter
;~~~~~~~~~~~~~~~~~~~~~~~~~~
;BA
-LCA_KOMM,12
;P0
W
DB1
; DB LCA-datafield of 132 words
;P1
W
&EZ50
; startaddress of the Profibus-Input (8 bytes)
;P2
W
&AZ50
; startaddress of the Profibus-Output (8bytes)
;P3
B E0.3
; B
restart input
;P4 W -TIMER
; T
Watch-Dog LCA-communication
;P5
W
K4.2
; K
timevalue for „watch dog“
;P6 W M100.0
; B
output-bit for communication error
;P7 W -INIT
; PB INIT (communication init LCA)
;P8
W
-COFF
; PB COFF (communication error LCA)
;P9
W
M100.2
; B
for internal use
;P10 W
M100.3
; B
for internal use
;P11 W
M100.4
; B
for internal use
;**************************************************************************
;
p r o g r a m
;**************************************************************************
;**************************************************************************
;
; processor reset => reset BT9_KOM
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
U
B
SM20.0
O
B
SM20.7
SPB
-START_KO
; ——————>
BX
P0
U
SPB
U
SPB
B
B
P10
-WAITDAT1
P11
-WAITDAT2
;second cycle to catch whole data (inputs)
;second cycle to write whole data (outputs)
; no process if timeout and restart input = 0
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
UN
B
P3
; timeout ?
U
B
P6
; restart ?
BEB
; instruction-number = 0 => wait for instruction-number = n,
; if instruction-number = n => process recived data
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
XO
W
B,B
; A Register = 0
L
W
P1,A
; instruction-number = 0 ? Input
L
BY
[A],A
VGL
BY
A,B
SPZ
-NO_AUFTR
; —————>
BX
P0
; open LCA-DB
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-11
B
Bosch PLC
; instruction-number > 0 => process the instructions
;
;**************************************************************
;**************************************************************************
; Have the whole instruction received ?
L
L
L
VGL
SPZ
L
L
ADD
L
VGL
SPN
BY
W
BY
BY
DX3,B
P1,A
[A],A
A,B
-NO_AUFTR
P1,A
[A],B
K07H,A
[A],A
A,B
-NO_AUFTR
=
BE
B
P10
; old instruction-number in byte 3
; load instruction-number (input)
; compare old with new
; if even —> no new instructions
W
; load address of receive inputs
BY
; load instruction-number 1.byte
W
;
BY
; load instruction-number last byte
BY
; compare first with last
; if not even -> instructions are not
; complete
;**************************************************************************
;
UN
B
P9
; set wait-flag and wait one cycle
U
=
-WAITDAT1
B
P9
B
P10
L
ADD
L
ADD
L
T
W
W
W
W
W
BY
;reset the wait-flag
P1,A
K1H,A
P2,B
K1H,B
K2H,D
D,DX2
; indir.address of datainputs
; at byte 2 load first instruction
; indir.address of dataoutputs
; reset receive-counter
; DX2 = receive-counter
;==========================================================================
; analyse of the instructions
L
PUSH
ADD
L
T
U
VGL
SPZ
VGL
SPZ
VGL
SPZ
VGL
SPZ
POP
SP
B-12
-read_new
; < - - - BY
[A],C
; read actual instruction
W
W
BY
BY
BY
BY
BY
BY
BY
W
C
K1,A
[A],C
C,D
KF0H,C
K10H,C
-READ ; —>
K20H,C
-WRITE
K40H,C
-WRITE_LB
K80H,C
-WRITE_RB
C
-AUFT_END
; read instruction
; write „word“ instruction
; ——>
; write high byte instruction
; ——>
; write low byte instruction
; ———>
; no instruction
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
;=========================================================================
; read instuction: copy data from LCA-datafield to send-outputs
;=========================================================================
POP
PUSH
-READ ; <—W
C
W
A
L
U
SLL
O
L
U
BY
W
W
W
BY
BY
VGL
SPZ
INC
L
T
DEC
INC
L
T
INC
INC
DEC
SP
-return_r
; < - BY
K0H,C
-r_end
W
A,1
BY
[A],D
BY
D,[B]
W
A,1
W
B,1
BY
[A],D
BY
D,[B]
W
B,1
W
A,2
BY
C,1
-return_r
; - -
; pointer receive inputs to stack
C,A
K00FFH,A
A,1
K1800H,A
D,C
K0FH,C
;load LCA-dataword-address
; * 2
; add to indirect address LCA-datafield
; load instruction
; mask count of datawords
; copy until count of datawords = 0
; read instruction end
; load highbyte from LCA-datafield
; write to send-outputs
;
;
;
;
;
;
>
increment send pointer
load lowbyte from LCA-datafield
write to send-outputs
increment send pointer
increment datafield-address
decrement dataword counter
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-r_end
POP
W
A
; load from stack receive pointer
SP
-AUFT_END
;
end read instruction
;==========================================================================
;==========================================================================
; write word instruction: copy datawords from receive inputs to datafield
;==========================================================================
POP
PUSH
-WRITE
W
C
W
B
L
U
SLL
O
L
U
PUSH
INC
W
W
W
W
BY
BY
W
W
; <——
; send pointer to the stack
C,B
K00FFH,B
B,1
K1800H,B
D,C
K0FH,C
C
A,1
-return_w
; < - -
; load LCA-dataword-address
; * 2
; add to indirect address LCA-datafield
; load instruction
; mask count of datawords
; dataword counter to the stack
; increment receive pointer
copy until dataword counter = 0
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-13
B
Bosch PLC
VGL
SPZ
INC
L
T
DEC
INC
L
T
INC
INC
DEC
SP
BY
W
BY
BY
W
W
BY
BY
W
W
BY
K0H,C
-w_end
B,1
[A],D
D,[B]
B,1
A,1
[A],D
D,[B]
A,1
B,2
C,2
-w_end
;
;
;
;
;
;
;
;
;
;
; - - >
; write instruction end
receive address of high byte
load byte from receive inputs
and store it as high byte
receive address of low byte
increment datafield address
load byte from receive inputs
and store it as low byte
increment datafield address
increment receive pointer
decrement dataword counter
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-w_end
POP
W
C
; load from stack dataword counter
POP
W
B
; load from stack send pointer
SP
-AUFT_END
; ———>
;
end write instruction
;=====================================================================
;==========================================================================
; write high byte instruction: copy high byte of dataword to the datafield
;==========================================================================
POP
PUSH
-WRITE_LB
W
C
W
B
; <——
L
U
SLL
O
L
U
PUSH
INC
W
W
W
W
BY
BY
W
W
VGL
SPZ
INC
L
T
INC
DEC
SP
-return_l
; < - BY
K0H,C
-lb_end
W
B,1
BY
[A],D
BY
D,[B]
W
A,2
BY
C,1
-return_l
; - -
; send pointer to the stack
C,B
K00FFH,B
B,1
K1800H,B
D,C
K0FH,C
C
A,1
; load LCA-datword-address
; * 2
; add to indirect address LCA-datafield
; load instruction
; mask count of datawords
; dataword-counter to the stack
; increment receive pointer
;copy until dataword counter = 0
;
;
;
;
;
>
; write high byte instruction end
receive address of high byte
load byte from receive inputs
and store it as high byte
increment receive pointer
decrement dataword counter
; is there another instruction ?
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-lb_end
POP
W
C
; load from stack dataword counter
POP
W
B
; load from stack send pointer
SPZ
-AUFT_END
; ———>
;
end write high byte instruction
;==========================================================================
B-14
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
;==========================================================================
; write low byte instruction: copy high byte of dataword to the datafield
;==========================================================================
-WRITE_RB
; <——
POP
PUSH
W
W
C
B
L
U
SLL
O
L
U
PUSH
INC
W
W
W
W
BY
BY
W
W
C,B
K00FFH,B
B,1
K1800H,B
D,C
K0FH,C
C
A,1
VGL
SPZ
INC
L
T
INC
DEC
SP
-return_b
BY
K0H,C
-rb_end
W
A,1
BY
[A],D
BY
D,[B]
W
A,1
BY
C,1
-return_b
; send pointer to the stack
; load LCA-dataword-address
; * 2
; add to indirect address LCA-datafield
; load instruction
; mask count of datawords
; dataword-counter to the stack
; increment receive pointer
; copy until dataword-counter = 0
;
;
;
;
;
; - - >
; write low byte instruction end
receive address of low byte
load byte from receive inputs
and store it as high byte
increment receive pointer
decrement dataword counter
; is there another instruction ?
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-rb_end
POP
W
C
; load from stack dataword counter
POP
W
B
; load from stack send pointer
SPZ
-AUFT_END
;
end write low byte instruction
;==========================================================================
;==========================================================================
; AUFT_END: all instructions are done
;==========================================================================
-AUFT_END
; <———L
W
P1,A
ADD
W
K5H,A
L
BY
[A],A
T
BY
A,DX9
L
W
P1,A
ADD
W
K6H,A
L
BY
[A],A
T
BY
A,DX8
UN
=
B
B
P9
P11
; wait one cycle to be sure that
; all outputs are refreshed
BE
; Invert instruction-number and write it to the first and last byte
; of the communication outputs
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-15
B
Bosch PLC
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-WAITDAT2
U
B
P9
; reset wait-flag
=
B
P11
L
L
T
XO
L
T
ADD
T
W
BY
BY
BY
W
BY
W
BY
P1,A
[A],D
D,DX3
KFFH,D
P2,A
D,[A]
K7H,A
D,[A]
; watch dog
;~~~~~~~~~~~
; trigger timer
;————————————————————
U
W
P5,D
U
B
SM30.3
SE
D,P4
U
R
B
B
; load instruction-number
; store it in byte 3
; invert the instruction number
; store it in the first and last
; output bytes
; timevalue
;
SM31.1
P6
; Watchdogmerker reset
BE
; ———————————————————————————>
;
end instructions
;==========================================================================
;**************************************************************************
;==========================================================================
; no new instructions
;==========================================================================
-NO_AUFTR
; <—————
L
U
SE
W
B
P5,D
SM31.1
D,P4
U
BEI
B
P4
; timevalue
; timeout ?
; set fault
watch dog has responsed
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-KOMM_FEL
S
XO
B
W
P6
D,D
; watch dog
; init aftzer communication error
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~
BA
P0
; open LCA-DB
BA
P8
; COFF
BE
; ———————————————————————————>
;
end watch dog
;**************************************************************************
B-16
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B
Bosch PLC
;=========================================================================
; start of communication
;========================================================================
-START_KO
; start timer
;~~~~~~~~~~~~~~~~~~~~
L
W
P5,D
; timervalue
U
B
SM30.3
SE
D,P4
; reset fault
;~~~~~~~~~~~~~~~
U
B
SM31.1
R
B
P6
XO
W
; watch dog
D,D
; init output at the first cycle
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
L
W
P2,A
T
W
D,[A]
;
; INIT LCA-DB at first cycle
;~~~~~~~~~~~~~~~~~~~~~~~~~~~~
BA
P0
BA
P7
BE
; ———————————————————————————>
;
end start communication
;**************************************************************************
;Programm Ende
;**************************************************************************
;** INIT: Subroutine INIT inits the LCA-Datafield at the first cycle
;**
The user can program its own specifications
;**************************************************************************
HLT
;!!!!! Here you have to specify your init values
;**********************************
;********************************** !!!!! at least set your
;**********************************
Key-bytes to zero
;***** example for LCA *****
;L
BY
K0D,A
;T
BY
A,D6
;TASTEN
;T
BY
A,D7
;T
BY
A,D8
;T
BY A,D9
BE
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
B-17
B
Bosch PLC
;**************************************************************************
;** COFF: Subroutine COFF inits the LCA-Datafield after communication error
;**
( emergancy case ) The user can program its own specifications
;**************************************************************************
HLT
;!!!!! Here you have to specify your emergancy values
;**********************************
;**********************************
;**********************************
!!!!! CAUTION !!!!!
;**********************************
at least set the Key-Bytes to zero
;**********************************
;***** example for LCA *****
;L
;T
;T
;T
;T
BY
BY
BY
BY
BY
K0D,A
A,D6
A,D7
A,D8
A,D9
;operator text
;keys
;printer status
;key-event
BE
B-18
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103
Index
B
P
Bus parameters ................................................ A-5
Parameters of the LCA_KOMM block ............... A-7
Profibus-DP network ...................................... A-14
Programmable controller ................................. A-4
C
COFF .............................................................. A-12
Configuration parameter .................................. A-5
CP5431 .................................................... A-5, A-6
D
DESI-DP ...........................................................
Determination of the configuration ..................
DP master ........................................................
DP slaves ..........................................................
A-4
A-4
A-8
A-8
R
RFLM .............................................................. A-12
RSET ............................................................... A-12
S
Sinec L2-DP network ........................................ A-8
Slave parameters .............................................. A-6
Specifications ................................................. A-17
E
T
EROR .............................................................. A-12
ET200 parameter ............................................. A-5
time-out ......................................................... A-13
TIMT .............................................................. A-12
TIMZ .............................................................. A-12
Transfer ............................................................ A-6
TXFA .............................................................. A-12
H
Handling software ............................................ A-7
Host parameters ............................................... A-5
I
IM308B ............................................................ A-5
IM308C ............................................................ A-5
INIT ................................................................ A-12
U
UBDB ............................................................. A-12
V
Variable LCA station number .......................... A-13
Variable time-out ............................................ A-13
L
LCA station number ....................................... A-13
LCADP ............................................................. A-7
M
Master card ...................................................... A-4
Master parameters ........................................... A-6
© Systeme Lauer GmbH & Co KG • Kelterstr.59 • 72669 Unterensingen • Tel. (07022) 96 60-0 • Fax (07022) 96 60-103