Lutron Electronics VB-8206SD Operation Manual

Add to my manuals
31 Pages

advertisement

Lutron Electronics VB-8206SD Operation Manual | Manualzz

PCE Instruments UK Ltd.

Units 12/13 Southpoint Business Park

Ensign Way, Southampton

United Kingdom, SO31 4RF

Phone: +44 (0) 2380 98703 0

Fax: +44 (0) 2380 98703 9 email: [email protected]

Web: http://www.industrial-needs.com

http://www.pce-instruments.com

SD card real time datalogger, RS232/USB

VIBRATION METER

Model : VB-8206SD

Your purchase of this

VIBRATION METER with

SD CARD DATALOGGER marks a step forward for you into the field of precision measurement.

Although this METER is a complex and delicate instrument, its durable structure will allow many years of use if proper operating techniques are developed. Please read the following instructions carefully and always keep this manual within easy reach.

OPERATION MANUAL

TABLE OF CONTENTS

1. FEATURES...............................................................................

1

2. SPECIFICATIONS.....................................................................

2

3. FRONT PANEL DESCRIPTION....................................................

8

3-1 Display................................................................................................. 8

3-2 Power Button ( ESC, Backlight Button )................................................... 8

3-3 Hold Button ( Function Button, Next Button ).......................................... 8

3-4 REC Button ( Enter Button, Unit Button )................................................ 8

8

3-6 Logger Button ( Button, Sampling time check Button, Zero Button )

Max hold reset Button )........................................................................ 8

3-7 BNC Input Socket.................................................................................. 8

3-8 SD Card Socket..................................................................................... 8

3-9 RS-232 Output Terminal........................................................................ 8

3-10 Reset Button....................................................................................... 8

3-11 DC 9V Power Adapter Input Socket....................................................... 8

3-12 Battery Compartment/Cover................................................................. 8

3-13 Battery Cover Screws.......................................................................... 8

3-14 Stand................................................................................................. 8

3-15 Tripod Fix Nut..................................................................................... 8

3-16 Magnetic base.................................................................................... 8

3-17 Vibration Sensor................................................................................. 8

3-18 Input Socket of Vibration Sensor .......................................................... 8

3-19 Mini Plug of Cable................................................................................ 8

3-20 Sensor Cable....................................................................................... 8

3-21 Cable BNC Plug................................................................................... 8

4. MEASURING PROCEDURE.........................................................

9

4-1 Preparation........................................................................................... 9

4-2 Unit selection ( Acc./Velocity/Displacement selection )..............................10

4-3 Function selection ................................................................................ 11

4-4 Zero adjustment procedures...................................................................12

4-5 Data Hold.............................................................................................13

4-6 Data Record ( Max./ Min. reading ).........................................................13

4-7 LCD Backlight ON/OFF...........................................................................14

5. DATALOGGER..........................................................................

14

5-1 Preparation before execute datalogger function....................................... 14

15

5-3 Manual Datalogger ( Set sampling time = 0 second ).............................. 16

5-4 Check time information..........................................................................17

5-5 Check sampling time information............................................................17

5-6 SD Card Data structure..........................................................................17

6. Saving data from the SD card to the computer...........................

19

7. ADVANCED SETTING................................................................

20

7-1 Set clock time ( Year/Month/Date, Hour/Minute/ Second )........................21

7-2 Decimal point of SD card setting.............................................................22

7-3 Auto power OFF management ...............................................................22

7-4 Set beep Sound ON/OFF........................................................................23

7-5 Set sampling time ................................................................................ 23

7-6 SD memory card format.........................................................................23

8. POWER SUPPLY from DC ADAPTER............................................

24

9. BATTERY REPLACEMENT..........................................................

24

10. SYSTEM RESET......................................................................

25

11. RS232 PC serial interface........................................................

25

12. CLASSIFICATION RANGES.......................................................

27

13. SENSITIVITY RELATIVE according ISO 2954.............................

28

14. PATENT.................................................................................

29

1. FEATURES

* Applications for industrial vibration monitoring :

All industrial machinery vibrates. The level of vibration is a useful guide to machine condition. Poor balance, misalignment & looseness of the structure will cause the vibration level increase, it is a sure sign that the maintenance is needed.

* Frequency range 10 Hz - 1 kHz, sensitivity relative meet

ISO 2954.

* Professional vibration meter supply with vibration sensor

& magnetic base, full set.

* Metric & Imperial display unit

* Acceleration, Velocity, Displacement measurement.

* RMS, Max hold, Peak value measurement.

* Max. Hold reset button, Zero button.

* Wide frequency range.

* Data hold button to freeze the desired reading.

* Memory function to record maximum and minimum reading with recall.

* Separate vibration probe with magnetic base, easy operation.

* Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder , sampling time set from 1 second to 3600 seconds.

* Manual datalogger is available ( set the sampling time to 0 ), during execute the manual datalogger function, it can set the different position ( location ) No.

( position 1 to position 99 ).

* Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the

SD card into the computer, it can down load the all the measured value with the time information ( year/month/date/ hour/minute/second ) to the Excel directly, then user can make the further data or graphic analysis by themselves.

1

* SD card capacity : 1 GB to 16 GB.

* LCD with green light backlight, easy reading.

* Can default auto power off or manual power off.

* Data hold, record max. and min. reading.

* Microcomputer circuit, high accuracy.

* Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.

* RS232/USB PC COMPUTER interface.

2. SPECIFICATIONS

2-1 General Specifications

Circuit

Display

Custom one-chip of microprocessor LSI circuit.

LCD size : 52 mm x 38 mm

LCD with green backlight ( ON/OFF ).

Measurement Velocity, Acceleration, Displacement

Function

Unit

Acceleration, Velocity :

RMS, Peak, Max Hold.

Displacement : p-p ( peak-peak ), Max Hold p-p.

Measurement Metric Imperial

Frequency range

Circuit

Peak

Measurement

Velocity mm/s, cm/s inch/s

Displacement mm inch

10 Hz to 1 KHz

* Sensitivity relative during the the frequency range meet ISO 2954

Refer to table 1, page 28

Exclusive microcomputer circuit.

Acceleration, Velocity :

To measure and update the peak value.

Displacement :

To measure and update the peak to peak ( p-p ) value.

2

Max Hold

Measurement

Zero Button

Max. Hold Reset

Button

Datalogger

Sampling Time

Setting range

Acceleration, Velocity :

To measure and update the max. peak value.

Displacement :

To measure and update the max. peak to peak ( p-p ) value.

Under Acceleration ( RMS ) measurement, sensor motionless , press Logger Button

( 3-6, Fig. 1 ) > 5 seconds.

Under Max. hold measurement, press

Logger Button ( 3-6, Fig. 1 ) > 5 seconds.

Auto 1 second to 3600 seconds

@ Sampling time can set to 1 second, but memory data may loss.

Manual Push the data logger button once will save data one time.

@ Set the sampling time to

0 second.

@ Manual mode, can also select the

1 to 99 position ( Location ) no.

Memory Card SD memory card 1 GB to 16 GB.

Advanced setting

* Set clock time ( Year/Month/Date,

Hour/Minute/ Second )

* Decimal point of SD card setting

* Auto power OFF management

* Set beep Sound ON/OFF

* Set sampling time

Data error no.

Data Hold

* SD memory card Format

0.1 % no. of total saved data typically.

Freeze the display reading.

* Only available for the RMS function.

Memory Recall Maximum & Minimum value.

* Only available for the RMS function.

3

Data Output RS 232/USB PC computer interface.

* Connect the optional RS232 cable

UPCB-02 will get the RS232 plug.

* Connect the optional USB cable

USB-01 will get the USB plug.

Sampling Time Approx. 1 second.

of Display

Operating 0 to 50 .

Temperature Less than 85% R.H.

and Humidity

Power Supply

* A

( UM3, AA ) x 6 PCs, or equivalent.

* A adapter is optional ).

Power Current Normal operation ( w/o SD card save data and LCD Backlight is OFF) :

Approx. DC 15 mA.

When SD card save the data and LCD

Backlight is OFF) :

Weight

Dimension

Accessories

Included

Optional

Accessories

Approx. DC 36 mA.

Meter :

515 g/ 1.13 LB.

Probe with cable and magnetic base :

99 g/0,22 LB

Meter :

203 x 76 x 38 mm

Vibration sensor probe:

Round 16 mm Dia. x 37 mm.

Cable length : 1.2 meter.

* Instruction manual........................1 PC

* Hrad carrying case, CA-06.............1 PC

* Vibration sensor with cable............1 PC

* Magnetic base.............................. 1 PC

SD Card ( 2 G )

AC to DC 9V adapter.

USB cable, USB-01.

RS232 cable, UPCB-02.

Data Acquisition software,SW-U801-WIN.

4

Acceleration ( RMS, Peak, Max Hold )

Unit

Range

Resolution

Accuracy

Calibration

Point m/s^2

0.5 to 199.9 m/s^2

0.1 m/s^2

± ( 5 % + 2 d ) reading

@ 160 Hz, 80 Hz, 23 ± 5 ℃

50 m/S^2 ( 160 Hz )

Unit

Range

Resolution

Accuracy

Calibration

Point g

@ 1 g = 9.8 m/s^2

0.05 to 20.39 G

0.01 G

± ( 5 % + 2 d ) reading

@ 160 Hz, 80 Hz, 23 ± 5 ℃

50 m/S^2 ( 160 Hz )

Unit

Range

Resolution

Accuracy ft/s^2

2 to 656 ft/s^2

1 ft/s^2

± ( 5 % + 2 d ) reading

@ 160 Hz, 80 Hz, 23 ± 5 ℃

50 m/S^2 ( 160 Hz ) Calibration

Point

Remark :

RMS : To measure the true RMS value.

Peak : To measure and update the peak value.

Max. Hold : To measure and update the max. peak value.

5

Velocity ( RMS, Peak, Max Hold )

Unit

Range

Resolution

Accuracy

Calibration

Point mm/s

0.5 to 199.9 mm/s

0. 1 mm/s

± ( 5 % + 2 d ) reading

@ 160 Hz, 80 Hz, 23 ± 5 ℃

50 mm/s ( 160 Hz )

Unit

Range

Resolution

Accuracy

Calibration

Point cm/s

0.05 to 19.99 cm/s

0. 01 cm/s

± ( 5 % + 2 d ) reading

@ 160 Hz, 80 Hz, 23 ± 5 ℃

50 mm/s ( 160 Hz )

Unit

Range

Resolution

Accuracy inch/s

0.02 to 7.87 inch/s

0.01 inch/s

± ( 5 % + 2 d ) reading

@ 160 Hz, 80 Hz, 23 ± 5 ℃

50 mm/s ( 160 Hz ) Calibration

Point

Remark :

RMS : To measure the true RMS value.

Peak : To measure and update the peak value.

Max. Hold : To measure and update the max. peak value.

6

Displacement ( p-p, Max Hold p-p )

Unit

Range

Resolution

Accuracy

Calibration

Point mm

1.999 mm

0.001 mm

± ( 5 % + 2 d ) reading

@ 160 Hz, 80 Hz, 23 ± 5 ℃

0.141 mm ( 160 Hz )

Unit

Range

Resolution

Accuracy inch

0.078 inch

0.001 inch

± ( 5 % + 2 d ) reading

@ 160 Hz, 80 Hz, 23 ± 5 ℃

0.141 mm ( 160 Hz ) Calibration

Point

Remark : p-p :

To measure the Peak to Peak value.

Max. Hold p-p :

To measure and update the max. Peak to Peak value.

@ Above specification tests under the environment RF Field Strength less than 3 V/M & frequency less than 30 MHz only.

7

3. FRONT PANEL DESCRIPTION

Fig. 1

3-1 Display

3-2 Power Button ( ESC, Backlight Button )

3-3 Hold Button ( Function Button, Next Button )

3-4 REC Button ( Enter Button, Unit Button )

3-6 Logger Button ( Button, Sampling time check Button, Zero Button,

Max hold reset Button )

3-7 BNC Input Socket

3-8 SD Card Socket

3-9 RS-232 Output Terminal

3-10 Reset Button

3-11 DC 9V Power Adapter Input Socket

3-12 Battery Compartment/Cover

3-13 Battery Cover Screws

3-14 Stand

3-15 Tripod Fix Nut

3-16 Magnetic Base

3-17 Vibration Sensor

3-18 Input Socket of Vibration Sensor

3-19 Mini Plug of Cable

3-20 Sensor Cable

3-21 Cable BNC Plug

8

4. MEASURING PROCEDURE

4-1 Preparation

1)Turn on the meter by pressing the " Power Button "

( 3-2, Fig. 1 ) momentarily.

*

Pressing the " Power Button " ( 3-2, Fig. 1 ) continuously and > 2 seconds again will turn off the meter.

2)Plug in the " Cable BNC Plug " ( 3-21, Fig. 1 ) to the " BNC Input Socket " ( 3-7, Fig. 1 ).

3)Plug in the " Mini plug of cable " ( 3-19, Fig. 2 ) to the " Input socket of vibration sensor " ( 3-18, Fig. 2 ).

Remark :

1.

If the surface material of measuring article is not the ferrous material, hold the vibration sensor by

* hand & touch the sensor to the surface of the measuring article,

If the surface material of measuring article is the ferrous material, connect " Vibration sensor " (

*

3-17, Fig. 2 ) with the " Magnetic base " ( 3-16, Fig.

2 ). Put the whole unit ( Vibration sensor &

Magnetic base ) to the surface of measuring article.

Please do not use the finger or hand to touch the the " Sensor cable " ( 3-20, Fig. 1 ).

9

4-2 Unit selection ( Acc./Velocity/Displacement

selection )

Select the desired display unit by pressing the " Unit

Button " ( 3-4, Fig. 1 ) continuously ( not release the button ), the Display will show the following units according Acceleration/Velocity/Displacement in sequence.

Measurement Unit

Acceleration m/s^2, g, ft/s^2

* LCD show " ACC "

Velocity

* LCD show " VEL. " mm/s, cm/s, inch/s

* LCD show " DISP p-p"

ACC m/s^2

ACC g

VEL

VEL mm/s cm/s

DISP p-p mm

ACC ft/s^2

VEL inch/s

DISP p-p inch.

'Metric

unit

Imperial

unit

10

Remark :

1. For the Acceleration measurement, the Display will show the indicator " ACC "

2. For the Velocity measurement, the Display will show the indicator " VEL. "

3. For the Displacement measurement, the Display will show the indicator " DISP p-p "

4. For general applications of industrial vibration monitoring, select " Velocity " or " Acceleration " typically.

5. After select the unit will be saved into the circuit with

default.

4-3 Function selection

Select the desired function ( RMS, Peak, Max HOLD ) by pressing the " Function Button " ( 3-3, Fig. 1 ).

continuously ( not release the button ), until the

Display will show the desiring function ( RMS, Max

HOLD, Peak ) , then release the " Function

Button " ( 3-3, Fig. 1 ). The detail procedures, please refer to chapter 4-1, page 9. .

Remarks :

1. RMS measurement is intend to measure and root means square ( RMS ) value.

The Display will show the indicator " RMS ".

2. Max HOLD measurement is intend to measure and update the max. peak value.

The Display will show the indicator " MAX HOLD ".

Max hold reset procedures

Under execute the Max Hold function if press the

" LOGGER Button " ( 3-6, Fig. 1 ) continuously at least 5 seconds will clear the existing Max hold value.

11

3. Peak measurement is intend to measure the peak vibration value.

The Display will show the indicator " PEAK ".

4. After select the unit will be saved into the circuit with

default.

5. Acceleration and Velocity measurement can select 3 function : RMS, PEAK, MAX HOLD

* Typically, for Acceleration and Velocity measurement always select to the " RMS " measurement.

6. Displayment measurement can select 2 function :

" DISP p-p " or MAX HOLD ( DISP p-p )

* Typically, for Displacement measurement always select to the " DISP p-p " measurement.

4-4 Zero adjustment procedures

Due to drift of environment temperature value, battery power change, meter used for a long time or other reasons. The display value may exist not zero value ( few digits ) in case of no signal into the " Vibration Sensor ".

General speaking those not zero value will not effect the measurement typically. However if intend to make the precision measurement, the following zero adjustment procedures should be executed as :

1)Vibration sensor is ready, connect the " Plug of cable "

( 3-21, Fig. 1 ) into the " " Input socket " ( 3-7, Fig. 1 ).

2)Select the measurement to the " Acceleration "

3)Keep the vibration sensor motionless, no signal into the vibration sensor.

4)Press the " LOGGER Button " ( 3-6, Fig. 1 ) continuously at least 5 seconds will let the display reach zero value.

5)The zero adjustment can be execute only the display value show the no. less than 10 digits.

12

4-5 Data Hold

* Only available for the RMS function.

During the measurement, press the " Hold Button " ( 3-3,

Fig. 1 ) once will hold the measured value & the LCD will display a " HOLD " symbol.

Press the " Hold Button " once again will release the data hold function.

4-6 Data Record ( Max., Min. reading )

* Only available for the RMS function.

1)The data record function records the maximum and minimum readings. Press the " REC Button " ( 3-4, Fig.

1 ) once to start the Data Record function and there will be a " REC " symbol on the display.

2)With the " REC " symbol on the display : a) Press the " REC Button " ( 3-4, Fig. 1 ) once, the

" REC MAX " symbol along with the maximum value will appear on the display.

If intend to delete the maximum value, just press the " Hold Button " ( 3-3, Fig. 1 ) once, then the display will show the " REC. " symbol only & execute the memory function continuously.

b)Press the " REC Button " ( 3-4, Fig. 1 ) again, the

" REC MIN " symbol along with the minimum value will appear on the display.

If intend to delete the minimum value, just press the " Hold Button " ( 3-3, Fig. 1 ) once, then the display will show the " REC. " symbol only & execute the memory function continuously.

c) To exit the memory record function, just press the

" REC " button for 2 seconds at least. The display will revert to the current reading.

13

4-7 LCD Backlight ON/OFF

After power ON, the " LCD Backlight " will light automatically. During the measurement, press the "

Backlight Button " ( 3-2, Fig. 1 ) once will turn OFF the

" LCD Backlight ".

Press the " Backlight Button " once again will turn ON the

" LCD Backlight " again.

5. DATALOGGER

5-1 Preparation before execute datalogger function

a. Insert the SD card

Prepare a " SD memory card " ( 1 G to 16 G, optional ), insert the SD card into the " SD card socket " ( 3-8, Fig. 1).

the down case.

b. SD card Format

If SD card just the first time use into the meter, it recommend to make the " SD card Format " at first. , please refer chapter 7-6 ( page 23 ).

* It recommend strongly, do not use memory cards that have been formatted by other meter or by other installation ( such as camera... ). Reformat the memory card with your meter.

* If the SD memory card exist the trouble during format by the meter, use the Computer to reformat again can fix the problem.

14

c. Time setting

If the meter is used at first time, it should to adjust the clock time exactly, please refer chapter 7-1 ( page 21 ).

d. Decimal forThe numerical data structure of SD card is default used the " . " as the decimal, for example "20.6" "1000.53" . But in certain countries ( Europe ...) is used the " , " as the decimal point, for example " 20, 6 "

"1000,53". Under such situation, it should change the Decimal character at first, details of setting the Decimal point, refer to Chapter

7-2, page 22.

a. Start the datalogger

Press the " REC Button ( 3-4, Fig. 1 ) once , the LCD will show the text " REC ", then press the " Logger Button " (

3-6, Fig. 1 ), the " REC " will flashing, at the same time the measuring data along the time information will be saved into the memory circuit.

Remark :

*

How to set the sampling time, refer to Chapter 7-5,

* page 23

How to set the beeper sound is enable, refer to

Chapter 7-4, page 23

15

b. Pause the datalogger

During execute the Datalogger function , if press the

" Logger Button " ( 3-6, Fig. 1 ) once will pause the

Datalogger function ( stop to save the measuring data into the memory circuit temporally ). In the same time the text of " REC " will stop flashing.

Remark :

If press the " Logger Button " ( 3-6, Fig. 1 ) once again will execute the Datalogger again, the text of " REC " will flashing .

c. Finish the Datalogger

During pause the Datalogger, press the " REC Button " (

3-4, Fig. 1) continuously at least two seconds, the " REC " indication will be disappeared and finish the Datalogger.

5-3 Manual Datalogger ( Set sampling time = 0 second )

a. Set sampling time is to 0 second

Press the " REC Button ( 3-4, Fig. 1 ) once , the LCD will show the text " REC ", then press the " Logger Button " (

3-6, Fig. 1 ) once, the " REC " will flashing once and Beeper will sound once, at the same time the measuring data along the time information will be saved into the memory circuit. The lower Display will show the

Position ( Location ) no. and saved into the SD card too.

16

Remark :

During execute the Manual Datalogger, press the " ▼

Button " ( 3-5, Fig, 1 ) the lower no. ( position no. ) will flashing. It can use the " Button " ( 3-6, Fig. 1) or "

Button " ( 3-5, Fig. 1 ) to set the measuring position (

1 to 99, for example room 1 to room 99 ) to identify the measurement location , the lower Display will show P x ( x = 1 to 99 ). After the position no. is selected, t press the " Enter Button " ( 3-4, Fig. 1 ) to confirm.

b. Finish the Datalogger

Press the " REC Button " ( 3-4, Fig. 1) continuously at least two seconds, the " REC " indication will be disappeared and finish the Datalogger.

5-4 Check time information

During the normal measurement ( not execute the

Datalogger ), If press " Time check Button " ( 3-5, Fig. 1

) once , the lower LCD display will present the time information of Year, Month/Date, Hour/Minute

5-5 Check sampling time information

During the normal measurement ( not execute the

Datalogger ), If press " Sampling Button " ( 3-6, Fig. 1 ) once , the lower LCD display will present the Sampling time information in second unit.

5-6 SD Card Data structure

1) When the SD card is used into the meter, the SD card

When the first time, the SD card is used into the meter, the SD card will generate a folder :

VBB01

17

2)If the first time to execute the Datalogger, under the route VBB01\, will generate a new file name VBB01001.XLS.

After exist the Datalogger, then execute again, the data will save to the VBB01001.XLS until

Data column reach to 30,000 columns, then will generate a new file, for example VBB01002.XLS

3)Under the folder VBB01\, if the total files more than 99 files, will generate anew route, such as

VBB02\ ........

4)The file's route structure :

VBB01\

VBB01001.XLS

VBB01002.XLS

.....................

VBVBB01099.XLS

VBB02001.XLS

VBB02002.XLS

.....................

VBVBB02099.XLS

.....................

.....................

Remark :

XX : Max. value is 10.

18

6. Saving data from the SD card

to the computer ( EXCEL software )

1)After execute the Data Logger function, take away the

SD card out from the " SD card socket " ( 3-8, Fig. 1 ).

2)Plug in the SD card into the Computer's SD card slot

( if your computer build in this installation ) or insert the SD card into the " SD card adapter ". then connect the " SD card adapter " into the computer.

3)Power ON the computer and run the " EXCEL software ".

Down load the saving data file ( for example the file name : VBB01001.XLS, VBB01002.XLS ) from the SD card to the computer. The saving data will present into the EXCEL software screen ( for example as following

EXCEL data screens ) , then user can use those EXCEL data to make the further Data or Graphic analysis usefully.

EXCEL data screen ( for example )

19

EXCEL graphic screen ( for example )

7. ADVANCED SETTING

Under do not execute the Datalogger function, press the " SET Button " ( 3-5, Fig. 1 ) continuously at least two seconds will enter the " Advanced Setting " mode.

then press the " Next Button " (3-3, Fig. 1 ) once a while in sequence to select the eight main function, the lower display will show :

dAtE......Set clock time ( Year/Month/Date, Hour/Minute/

Second )

dEC.......Set SD card Decimal character

PoFF..... Auto power OFF management

bEEP.....Set beeper sound ON/OFF

SP-t...... Set sampling time ( Hour/Minute/Second )

Sd F..... SD memory card Format

20

Remark :

During execute the " Advanced Setting " function, if press " Esc Button " ( 3-2, Fig. 1 ) once will exit the " Advanced Setting " function, the LCD will return to normal screen.

7-1 Set clock time ( Year/Month/Date,

Hour/Minute/ Second )

When the lower display show " dAtE "

1)Press the " Enter Button " ( 3-4, Fig. 1 ) once,

▲ ▼

( 3-5, Fig. 1 ) to adjust the value ( Setting start from

Year value ). After the desired value is set, press the

" Enter Button " ( 3-4, Fig. 1 ) once will going to next value adjustment ( for example, first setting value is Year then next to adjust Month, Date, Hour,

2)After set all the time value ( Year, Month, Date, Hour,

Minute, Second ), the screen will jump to " Decimal point of SD card " setting screen ( Chapter 7-2 ).

Remark :

After the time value is setting, the internal clock will run precisely even Power off if the battery is under normal condition ( No low battery power ).

21

7-2 Decimal point of SD card setting

The numerical data structure of SD card is default used the " . " as the decimal, for example "20.6" "1000.53" .

But in certain countries ( Europe ...) is used the " , " as the decimal point, for example " 20,6 " "1000,53".

Under such situation, it should change the Decimal character at first.

When the lower display show " dEC "

1)Use the " Button " ( 3-6, Fig. 1 ) or " Button "

( 3-5, Fig. 1 ) to select the upper value to " USA " or

" Euro ".

USA - Use " . " as the Decimal point with default.

Euro - Use " , " as the Decimal point with default.

2)After select the upper text to " USA " or " Euro ", press the " Enter Button " ( 3-4, Fig. 1 ) will save the setting function with default.

7-3 Auto power OFF management

When the lower display show " PoFF "

1)Use the " Button " ( 3-6, Fig. 1 ) or " Button "

( 3-5, Fig. 1 ) to select the upper value to " yES " or

" no ".

yES - Auto Power Off management will enable.

no - Auto Power Off management will disable.

2)After select the upper text to " yES " or " no ", press the

" Enter Button " ( 3-4, Fig. 1 ) will save the setting function with default.

22

7-4 Set beeper sound ON/OFF

When the lower display show " bEEP "

1)Use the " Button " ( 3-6, Fig. 1 ) or " Button "

( 3-5, Fig. 1 ) to select the upper value to " yES " or

" no ".

yES - Meter's beep sound will be ON with default.

no - Meter's beep sound will be OFF with default.

is power ON.

2)After select the upper text to " yES " or " no ", press the

" Enter Button " ( 3-4, Fig. 1 ) will save the setting function with default.

function with default.

7-5 Set sampling time ( seconds )

When the lower display show " SP-t "

3-5, Fig. 1 ) to adjust the value ( 1, 2, 5, 10, 30,60,

120, 300, 600, 1800,3600 seconds ).

2)After the Sampling value is selected, press the "

Enter Button " ( 3-4, Fig. 1 ) will save the setting function with default.

7-6 SD memory card Format

When the lower display show " Sd F "

3-5, Fig. 1 ) to select the upper value to " yES " or

" no ".

23

yES - Intend to format the SD memory card no - Not execute the SD memory card format

2)If select the upper to " yES ", press the " Enter Button

" ( 3-4, Fig. 1 ) once again, the Display will show text

" yES Enter " to confirm again, if make sure to do the

SD memory card format, then press " Enter Button " once will format the SD memory clear all the existing data that already saving into the SD card.

8. POWER SUPPLY from DC

ADAPTER

The meter also can supply the power supply from the

DC 9V Power Adapter ( optional ). Insert the plug of

Power Adapter into " DC 9V Power Adapter Input Socket

" ( 3-11, Fig. 1 ). The meter will permanent power ON when use the DC ADAPTER power supply ( The power

Button function is disable ).

9. BATTERY REPLACEMENT

1)When the left corner of LCD display show " ", it is necessary to replace the battery. However, in-spec.

measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate.

2)Loose the screws of the " Battery Cover Screws " ( 3-13,

Fig. 1 ) and take away the " Battery Cover " ( 3-12, Fig. 1 ) from the instrument and remove the battery.

3)Replace with DC 1.5 V battery ( UM3, AA,

Alkaline/heavy duty ) x 6 PCs, and reinstate the cover.

4)Make sure the battery cover is secured after changing the battery.

24

10. SYSTEM RESET

If the meter happen the troubles such as :

CPU system is hold ( for example, the key button can not be operated... ).

Then make the system RESET will fix the problem.

The system RESET procedures will be either following method :

During the power on, use a pin to press the " Reset

Button " ( 3-10, Fig. 1 ) once a while will reset the circuit system.

11. RS232 PC SERIAL INTERFACE

The instrument has RS232 PC serial interface via a 3.5

mm terminal ( 3-9, Fig. 1 ).

The data output is a 16 digit stream which can be utilized for user's specific application.

A RS232 lead with the following connection will be required to link the instrument with the PC serial port.

25

Meter PC

(9W 'D" Connector)

Center Pin..........................Pin 4

(3.5 mm jack plug)

Ground/shield.......................Pin 2

2.2 K resistor

Pin 5

The 16 digits data stream will be displayed in the following format :

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0

Each digit indicates the following status :

D15

D14

Start Word

4

D13 1

D12, D11 Annunciator for Display

D10

= 92

mm/s = 93

mm = 94

0

= 97

cm/s = 95

inch = 96

inch/s = 98

g = 57

D9 Decimal Point(DP), position from right to the left

0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP

D8 to D1 Display reading, D1 = LSD, D8 = MSD

For example :

If the display reading is 1234, then D8 to

D0

D1 is : 00001234

End Word

26

RS232 FORMAT : 9600, N, 8, 1

Baud rate

Parity

Data bit no.

Stop bit

9600

No parity

8 Data bits

1 Stop bit

12. CLASSIFICATION RANGES

For the valuation of machines and equipment in the ISO

2372 and VDI 2056, four different kinds of machine groups with four classification ranges and their limits for vibration severity ( mm/s ) are determined.

The classifications for each machine group are specified as follows :

Small machines, especially production electrical motors of up to 15 KW ( Group K )

Good

Acceptable

Still permissible

Dangerous

0 to 0.71 mm/s

0.72 to 1.80 mm/s

1.81 to 4.5 mm/s

> 4.5 mm/s

Medium sized machines, especially electrical motors with 15 up to 75 KW output, without special foundations ( Group M )

Good

Acceptable

Still permissible

Dangerous

0 to 1.12 mm/s

1.13 to 2.80 mm/s

2.81 to 7.1 mm/s

> 7.1 mm/s

27

Large machines on heavy foundations ( Group G )

Good

Acceptable

Still permissible

Dangerous

0 to 1.80 mm/s

1.81 to 4.50 mm/s

4.51 to 11.2 mm/s

> 11.2 mm/s

Largest machines and turbo machines with a special foundations ( Group T ).

Good

Acceptable

Still permissible

Dangerous

0 to 2.80 mm/s

2.81 to 7.10 mm/s

7.11 to 18.0 mm/s

> 18 mm/s

13. SENSITIVITY RELATIVE to the reference sensitivity at 80 Hz , according ISO 2954

Frequency Normal Relative

10

20

40

80

Table 1 value

Hz 1.0

Hz 1.0

Hz 1.0

Hz 1.0

160 Hz 1.0

500 Hz 1.0

1000 Hz 1.0

Minimum Maximum value

0.8

0.9

0.9

1.0

0.9

0.9

0.8

value

1.1

1.1

1.1

1.0

1.1

1.1

1.1

28

14. PATENT

The meter ( SD card structure ) already get patent or patent pending in following countries :

Germany

JAPAN Nr. 20 2008 016 337.4

TAIWAN 3151214

M 358970

CHINA M 359043

ZL 2008 2 0189918.5

USA ZL 2008 2 0189917.0

Patent pending

29

1009-VB8206SD

advertisement