Quanta System Light Series Laser

Add to my manuals
4 Pages

advertisement

Quanta System Light Series Laser | Manualzz

DERMATOLOGY AND

AESTHETIC MEDICINE

MEDICAL DIVISION

Light Series

Clinic in a System Dermatologic Platform

Multiple Wavelengths for the higher

Challenges in Laser Applications

PERMANENT HAIR REDUCTION

DERMATOLOGICAL VASCULAR LESIONS REMOVAL

INFLAMMATORY ACNE TREATMENTS

NON-ABLATIVE SKIN TREATMENTS

SKIN REJUVENATION PROCEDURES

ABLATIVE FRACTIONAL SKIN RESURFACING

(TWAIN 2940)

This brochure is not intended for the USA market. Certain Intended Uses/Configurations/Models/Accessories are not cleared for USA

Multiple Wavelengths for the higher Challenges in Laser Applications

Light Series has been developed to satisfy the needs of doctors and clinics, which today can perform a wide range of dermatologic and aesthetic applications by using a single device, instead of purchasing different lasers.

The system can include different laser sources, such as a long pulsed Alex-

andrite (755 nm), a long and short pulsed Nd:Yag 1064 nm, a long pulsed Nd:Yag 532 nm and long

pulsed 1320 nm.

The large variety of available handpieces, with different variable and fixed spot sizes, gives the possibility to perform quick treatments by choosing an appropriate fluence.

The laser emission parameters can be easily set allowing effective treatments of any skin type.

Light Series, via a TWAIN connector, can be upgraded with a Er:Yag 2940 nm and IPL handpiece enhancing the treatment flexibility and versatility.

Due to its modularity and flexibility, the NEW Light Series allows a quick return of investment.

LIGHT SERIES & APPLICATIONS

Light A

Alexandrite (755 nm) long pulsed laser.

Applications:

• Permanent hair reduction of I-IV

skin phototypes

• Benign pigmented lesions

removal

Light B

Nd:Yag (1064 nm) short and long pulsed laser.

Applications:

• Permanent hair reduction of every

skin phototypes

• Dermatological vascular treatments

• Skin rejuvenation procedures

Light A* (Star)

This platform combines the Light A

and Light B performances.

It operates both at 755 and 1064 nm,

OPTIONS

Twain IPL

Light Series can be equipped, at any treatment time, with an optional IPL, enhancing flexibility and versatility.

Applications:

• Permanent hair reduction

• Benign pigmented lesions removal

• Skin rejuvenation procedures

• Dermatological vascular treatments

• Inflammatory acne treatments

PWS allowing the treatments as described for the Light A and B, respectively.

Light C

Combination of Nd:Yag 1064 nm short and long pulsed and Nd:Yag

532 nm long pulsed.

In addition to the treatments performed with Light B, Light C is indicated for treatments such as:

• Dermatological vascular lesions

• Skin rejuvenation

• Benign pigmented lesions

Light 4 V

Combination of Alexandrite (755 nm), Nd:Yag 1064 nm short and long pulsed and Nd:Yag 532 nm long pulsed.

Up to four wavelengths “all in one unit” for the maximum flexibility.

A complete system which allows to perform all the treatments indicated with LIGHT A, LIGHT B and LIGHT C.

Ultralight

Combination of Q-Switched

Nd:Yag 1064 and 532 nm plus

Nd:Yag 1064 nm short and long pulsed and Nd:Yag 532 nm long

pulsed, all in one unit.

The only system with 1064 + 532, both Q-Switched and long pulsed

Nd:Yag laser, available on the market.

In addition to the treatments performed with LIGHT C, this system can be used for:

• Multicoloured tattoo removal

• Benign epidermal and dermal

pigmented lesions removal.

Twain 2940

Optional for each series is an Erbium

Yag laser all built into an handpiece.

Through this module both fractional and traditional ablative skin resurfacing procedures are possible.

This TWAIN represents the ideal solution for fast skin texture and wrinkle improvement.

Applications:

• Ablative Fractional Resurfacing

• Skin peels

• Removal of benign skin lesions

Nd:Yag 1320 (Light A* Star)

Optional for any long pulsed

Nd:Yag of this Series is the 1320 nm wavelength.

Due to its higher absorption by water and great penetration into the dermis, it is very effective for nonablative skin treatments.

Twain IPL handpiece

2-5 mm variable spot size handpiece Twain 2940 handpiece Integrated optional contact skin cooler

Multiple Wavelengths for the higher Challenges in Laser Applications

CLINICAL RESULTS

PERMANENT HAIR REDUCTION

Courtesy of E. Bonizzoni MD

BENIGN PIGMENTED LESIONS

Before After 5 treatments

DERMATOLOGICAL VASCULAR LESIONS

Courtesy of P. Sbano MD

Before

SKIN REJUVENATION

Courtesy of E. Bonizzoni MD

After

Before After 3 treatment Before After

MODEL

Permanent hair reduction

Dermatological vascular lesions

Skin rejuvenation

Fractional ablative rejuvenation

Light A Light B Light A * Light C Light 4V Ultralight Twain IPL Twain 2940 Nd:Yag 1320

Benign epidermal pigmented lesions removal

• • • • • • •

• • • • • • •

Benign dermal pigmented lesions removal

Surgical dermatology

VISIBLE AND INVISIBLE LASER RADIATION

Avoid eye skin exposure to direct or scattered radiation

Laser product: Class 4

Aiming beam: Class 3R

CAUTION - Laser radiation

DERMATOLOGY AND

AESTHETIC MEDICINE

MEDICAL DIVISION

Light Series

Laser

Wavelength

Pulse width

Repetition rate

Spot size

Max fluence

[mm]

[J/cm 2 ] up to 123

@ 6 mm

Skin Cooler

Electrical requirements

Dimensions and weight

Light B

Alexandrite Nd:Yag

[nm]

[ms]

755

2-100

[Hz] up to 2

1064 long pulse 1064 short pulse

2-100 up to 2

0.3-1 up to 7 up to 14 up to 6

>800 up to 30

@ 2 mm @ 5 mm up to 16

755

2-100 up to 2 up to 16 up to 123

@ 6 mm

Light A*

Nd:Yag up to 14

>800

@ 2 mm

Light C

Nd:Yag

1064 long pulse 1064 short pulse 1064 long pulse 1064 short pulse

3-300 0.3-1 3-300 0.3-1 up to 2 up to 7 up to 2 up to 7 up to 14

>800

@ 2 mm

up to 6 up to 30

@ 5 mm

up to 6 up to 30

@ 5 mm contact or air integrated with the handpiece (1)

230 V ac; 16 A; 50/60 Hz

480(W) x 900 (D) x 930 (H) mm; 90 Kg

(1) Optional

532 up to 25

1 up to 6 up to 95

@ 2 mm

MODEL

Laser Alexandrite

Wavelength

Pulse width

Repetition rate

[nm]

[ms]

[Hz]

755

2-100 up to 2

Light 4 V

Nd:Yag

1064 long pulse 1064 short pulse 532

2-100 0.3-1 up to 25 up to 2 up to 7 1

Spot size

Max fluence

Skin Cooler

Electrical requirements

Dimensions and weight

[mm] up to 16

[J/cm 2 ] up to 123

@ 6 mm up to 14

>800

@ 2 mm

up to 6 up to 30

@ 5 mm

Nd:Yag

1064 long pulse 1064 short pulse

2-100 0.3-1 up to 2 up to 7 up to 6 up to 95

@ 2 mm up to 14

>800

@ 2 mm

up to 6 up to 30

@ 5 mm contact or air integrated with the handpiece (1)

230 V ac; 16 A; 50/60 Hz

480(W) x 900 (D) x 930 (H) mm; 90 Kg

Ultralight

532 up to 25

1 up to 6 up to 95

@ 2 mm

(1) Optional

Q-Switched Nd:Yag

1064 532

6 ns 6 ns up to 10 up to 10 up to 5x5

22

@ 2x2 mm up to 5x5

11

@ 2x2 mm

OPTION

Source

Wavelength

Pulse width

Spot size

Max Fluence

Repetition rate

[J/cm 2 ]

[Hz]

Twain 2940

Er:Yag

95 up to 6 0,5

[nm]

[ms]

2940 650-1200

0.3 - 1

[mm] 2, 4, 9, fractional

625-1200

0,5

(2) Nd:Yag 1320 option available for Light A*, Light B, Light C, Light 4 V

Twain IPL

IPL handpieces

590-1200 570-1200

5 - 240

48x13 mm 2 - 25x13 mm 2 up to 30

0,5 0,5

550-1200

0,5

400-1200

0,5

Nd:Yag 1320 (2)

Nd:Yag

1320

5 - 10

8 - 10 up to 20 @ 8 mm up to 5

Note: National local authorities may put restrictions to the parameters indicated in the above table, or may limit or remove certain intended uses.

Specifications are subject to change without notice.

Quanta System products are manufactured according to the International standards and have been cleared by the most important International notified bodies. The Company is EN ISO 9001:2008 and EN ISO 13485:2012 certified. Quanta System S.p.A. was founded in 1985 and belongs to the EI. En. Group

(a public company listed in the Star segment of the Italian Stock Exchange) since January 2004. The company, divided into three business units (medical, scientific and industrial) is specialized in manufacturing of laser and opto-electronic devices.

Quanta System S.p.A

Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy

Tel. +39 0331.376797 - Fax +39 0331.367815

[email protected] www.quantasystem.com

This brochure is not intended for the USA market. Certain Intended Uses/Configurations/Models/Accessories are not cleared for USA

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project