Vizion UFL-440 Series Owner's Manual


Add to my manuals
20 Pages

advertisement

Vizion UFL-440 Series Owner's Manual | Manualzz

ManUFactUring nUMberS:

9700464

9700466

9700469

9700474

9700476

9700479

System Tested and Certified by NSF

International and WQA against NSF/ANSI

Standard 42 and 53 for the reduction of:

Standard No. 42: Aesthetic Effects

Nominal Particulate Reduction Class I

Standard No. 53: Health Effects

Cyst Reduction

Turbidity Reduction.

P/N 1010873 Rev. G 03/12

Water filtration system

UFL-420/440 Series

owner ’ s manual

UFL-420/440 water FiLtration system A.J. Antunes & Co.

table Of cOntents

Owner Information .....................................................2

General ......................................................................2

Warranty Information .................................................2

Service/Technical Assistance ....................................3

Important safety Information ....................................3

specifications .............................................................4

Electrical Ratings .......................................................4

Electrical Cord & Plug Configurations .......................4

Dimensions ................................................................4

performance Data sheet ............................................6

Filter Cartridge Capacities .........................................6

System Capacities .....................................................6

Performance Claims for Percent Reduction ..............6

Installation ...................................................................7

Unpacking ..................................................................7

Equipment Setup .......................................................7

Locating and Mounting the System ...........................8

Operation ...................................................................11

Filtration Process .....................................................11

LED Display .............................................................11

Starting the System .................................................11

Programming Timer During Startup .........................12

Setting the Flush Interval (Fi) ..................................12

Setting Flush Duration (FD) .....................................12

Manual Flushing ......................................................13

maintenance ..............................................................14

Checking the Timer Program ...................................14

Changing the Cartridges .........................................14

System Sanitization .................................................14

troubleshooting .......................................................15

wiring Diagram .........................................................16

replacement parts Ufl-420/440 .............................18

limited warranty ......................................back cover

Owner InfOrmatIOn

General

Antunes Filtration Technologies, Division of A.J.

Antunes & Co., has partnered with companies from around the globe to produce the UFL-Series water filtration systems. The UFL-Series reduces cysts and turbidity that can enter a typical water supply. This patented technology is now available to you, sized for your particular application. All filter configurations utilize

NeoH capillary membranes, providing the latest innovation in reusable surface filtration technology.

warranty Information

Please read the full text of the Limited Warranty in this manual.

If the unit arrives damaged, contact the carrier immediately and file a damage claim with them. Save all packing materials when filing a claim. Freight damage claims are the responsibility of the purchaser and are not covered under warranty.

The warranty does not extend to:

This manual provides the safety, installation and operating procedures for the UFL-Series water filtration systems. We recommend that all information contained in this manual be read prior to installing and operating the unit.

• Damages caused in shipment or damage as result of improper use.

• Installation of electrical service.

• Normal maintenance as outlined in this manual.

Your UFL-Series unit is manufactured from the finest materials available and is assembled to AFT’s strict quality standards. This unit has been tested at the factory to ensure dependable trouble-free operation.

• Malfunction resulting from improper maintenance.

• Damage from moisture leaking into electrical components.

• Normal maintenance as outlined in this manual.

• Damage from tampering with, removal of, or changing any preset control or safety device.

ImpOrtant! Keep these instructions for future reference. If the unit changes ownership, be sure this manual accompanies the equipment.

2 P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

UFL-420/440 water FiLtration system

Owner InfOrmatIOn (continued) service/technical assistance

If you experience any problems with the installation or operation of your unit, contact Antunes Filtration

Technologies at 1-630-784-1000, or toll free in the

United States at 1-800-253-2991.

Suggested replacement period for Cartridge is approximately 3 years.

For sales in the state of Iowa:

Fill in the information in the next column and have it handy when calling for assistance. The serial number is on the specification plate located on the unit.

Purchased From:

Date of Purchase:

Model No.:

Serial No.:

Mfg. No.:

ImpOrtant

a.J. antunes and company reserves the right to change specifications and product design without notice. such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.

ImpOrtant safety InfOrmatIOn

In addition to the warnings and cautions in this manual, use the following guidelines for safe operation of the unit.

• Read all instructions before using equipment.

• Install or locate the equipment only for its intended use as described in this manual. Do not use corrosive chemicals in this equipment.

• Do not operate this equipment if it has a damaged cord or plug; if it is not working properly, or if it has been damaged or dropped.

• This equipment should be serviced by qualified personnel only. Contact Antunes Filtration

Technologies for repair.

• Do not immerse cord or plug in water.

• Keep cord away from heated surfaces.

The following warnings and cautions appear throughout this manual and should be carefully observed.

• Disconnect the power source before performing any service or maintenance on the unit.

• All electrical connections must be in accordance with local electrical codes and any other applicable codes.

• WARNINg eLecTRIcAL ShocK hAzARD.

FAILURE To FoLLoW THESE INSTRUCTIoNS

CoULD RESULT IN SERIoUS INJURY oR DEATH.

- Do not modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.

- Do not use an extension cord with this appliance.

• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person.

• This equipment is to be installed to comply with the local plumbing code and any other applicable code.

• Water pressure must not exceed 100 psig (690 kPa). To reduce water pressure, install a water pressure regulator and set water pressure to suit application. Note that trans membrane pressure

(inlet water pressure minus the permeate water pressure) must not exceed 45 psi (310 kPa).

• System should be supplied only with cold water.

• commonwealth of Massachusetts Plumbing code

248 cMR shall be adhered to. The use of saddle valves are not permitted, please consult your local plumber.

• A ground fault circuit interrupter (gFcI) must be installed on the circuit to this system

• When installed on metallic plumbing, a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this device.

P/N 1010873 Rev. G 03/12 3

UFL-420/440 water FiLtration system

specIfIcatIOns electrical ratings

model &

mfg. no.

Voltage watts amps Hertz

UFL-420

9700464

120 10 0.4

50/60

230 10 0.4

50 UFL-420

9700466

UFL-420

9700469

UFL-440

9700474

UFL-440

9700476

UFL-440

9700479

220

120

230

220

10

10

10

10

0.4

0.4

0.4

0.4

50

50/60

50

50

Dimensions

A

electrical cord & plug configurations

120 Vac

(p/n 0700665)

230 Vac

(p/n 0700666)

C

A.J. Antunes & Co.

B

220 Vac

(p/n 0700682) china Only caUtIOn all electrical connections must be in accordance with local electrical codes and any other applicable codes.

a ground fault circuit interrupter (GfcI) must be installed on the circuit to this system.

when installed on metallic plumbing, a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this device figure 1. Dimensions

Ufl-420 a width b

Depth c

Height

Operating weight

(w/water)

(lbs)

11.5 in 6 in

Ufl-440

28 in 28 lbs.

min. clearance for cartridge change above or below unit

(inches)

19 in a width b

Depth c

Height

Operating weight

(w/water)

(lbs) min. clearance for cartridge change above or below unit

(inches)

38 in 11.5 in 6 in 47 in replacement cartrIDGe

42 lbs.

UFL-420

UFL-440

L-420 (P/N 7000411)

L-440 (P/N 7000412)

4 P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

components

UFL-420/440 water FiLtration system

specIfIcatIOns (continued)

permeate

Drain mounting bracket power transformer leD Display program button filter

Housing

P/N 1010873 Rev. G 03/12 figure 2. components

5 flow controller

Inlet

UFL-420/440 water FiLtration system A.J. Antunes & Co.

system capacities perfOrmance Data sHeet filter cartridge capacities

Maximum operating Pressure

Minimum operating Pressure

Maximum operating Temperature

Minimum operating Temperature

100 psig (690 kPa)

8 psig (55 kPa)

104°F (40°c)

40°F (4°c)

Maximum Trans Membrane Pressure 45 PSI (3.1 Bar) pH Range

MWco

3-10

100 kD

System Tested and Certified by NSF

International against NSF/ANSI

Standard 42 and 53 for the reduction of:

Standard No. 42: Aesthetic Effects

Nominal Particulate Reduction Class I

Standard No. 53: Health Effects

Cyst Reduction

Turbidity Reduction series

Liters per hour

Liters per minute

Gallons per hour

Gallons per minute

Ufl-420

1045

17

276

4.6

Ufl-440

2089

35

552

9.2

This system has been tested according to NSF/ANSI

Standard 42 and 53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI

42 or 53. While testing was performed under standard laboratory conditions, actual performance may vary.

performance claims for percent reduction

substance cyst

1

Turbidity

Particulate Class I

Particles 0.5 to <

1µm

Influent challenge concentration minimum

50,000/L

11+/1 NTU at least 10,000 particles /mL reduction requirement

99.95%

≤ 0.5 NTU

85% minimum

% reduction

99.95%

97.3%

N/A

1based on the use of microspheres or Cryptosporium parvum oocysts

Unpacking

1. Remove the system and all packing materials from the shipping carton.

2. Remove all packing materials and protective coverings from the system

3. Remove the information packet. To prevent any delay in obtaining warranty coverage, fill out and mail the warranty card.

nOte: If any parts are damaged, contact antunes filtration technologies ImmeDIately at 1-800-253-

2991 or 1-630-784-1000.

6 P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

UFL-420/440 water FiLtration system

equipment setup

General

InstallatIOn

When placing the unit into service, pay attention to the following guidelines:

If soldered plumbing is used, do not apply heat to, or near, the filtration system. The use of union (o-ring seal) connections is highly recommended for ease of installation and future servicing.

sUGGesteD tOOls anD sUpplIes fOr InstallatIOn

• Do not immerse cord or plug in water.

• Keep cord away from heated surfaces.

electrIcal

The following tools and supplies are suggested to make the installation easier:

Ensure that the line voltage corresponds to the stated voltage on the units specification label. Make sure that the plug on the power cord from the system and the outlet match. For proper operation, and to ensure the highest quality water from the system, make sure that the system is not connected to a switched electrical outlet.

• Screwdriver

• Drill with bits

• Tape measure

• Two gallon bucket

• Pipe wrenches

• Adjustable wrenches

• Level

• Pipe dope or thread seal

tape

• Fresh 5 1/4% liquid chlorine

bleach plUmbInG nOte: this unit is designed to use tap water not to exceed 100°f (38°c) or 100 psig (690 kpa).

caUtIOn this equipment is to be installed to comply with the basic plumbing code of the building Officials and code administrators, Inc. (bOca) and the food service sanitation manual of the food and

Drug administration (fDa).

The UFL-420 and UFL-440 systems use the following connections (Figure 1):

• Water Inlet

• Permeate (Product Water)

1” NPT

1” NPT

• Drain 3/4” NPT

When making a plumbing connection to the system, remember to use a back-up wrench on the supporting plumbing. Always use a good quality, approved pipe sealant or thread seak tape on pipe threads. Be careful not to get the pipe sealant inside the pipe when making the connections.

DO nOt over tighten the connections. It is recommended that plastic fittings be used when connecting to the plastic connections of the system. This will reduce the possibility of cracking the connections due to overtightening. caUtIOn water pressure must not exceed 100 psig (690 kpa). to reduce water pressure, install a water pressure regulator and set water pressure to suit application. note that the trans membrane pressure must not exceed 45 psi (310 kpa).

flOw reGUlatOr assembly

Your filtration system uses a water Flow Regulator

Assembly that controls the flow of water into the unit.

This assembly consists of a white threaded male connector and a color-coded Flow Regulator (Figure 3).

The unit mUst be operated with the appropriate Flow

Regulator Assembly.

ImpOrtant commonwealth of massachusetts plumbing code

248 cmr shall be adhered to. the use of saddle valves are not permitted, please consult your local plumber.

• UFL-420 Units: Use a Green and WHITE Flow

Regulator Assembly (5 gallons per minute).

• UFL-440 Units: Use a blacK and WHITE Flow

Regulator Assembly (10 gallons per minute).

caUtIOn flow regulator assemblies are nOt interchangeable. Operating the system with the wrong flow regulator or without a flow regulator can damage the system, cause personal injury, and will void the warranty!

P/N 1010873 Rev. G 03/12 7

UFL-420/440 water FiLtration system A.J. Antunes & Co.

InstallatIOn (continued) locating and mounting the system

Consider these points before mounting the system:

• Note the location of the water supply, drain, and an appropriate electrical outlet when choosing a mounting location.

ImpOrtant commonwealth of massachusetts plumbing code

248 cmr shall be adhered to. the use of saddle valves are not permitted, please consult your local plumber.

• Remember to allow for access to the timer/ programmer controls.

• Do not mount the system above any electrical equipment, or items that may be damaged if they get wet.

• Install the system in a location that will allow for future service access. Cartridge replacement will be either through the top or bottom of the housing. nOte: be sure to allow access to both the top and bottom of the housing.

Into

Filter

Base

Inset water flow

Flow Controller

(Green for UFL-420,

Black for UFL-440)

Flow Control

(supplied,

see inset)

Sanitation

Plug (not supplied)

Inlet Water

Valve (not supplied)

• Mount the system on a wall using appropriate mounting hardware.

• Remember to consider the operating weight of the system when choosing mounting hardware.

Depending on the type of wall the system is being mounted to, wall reinforcement may be necessary.

Mount the filtration unit using the Mounting Bracket

(Figure 2) using 1/4” by 1” bolts or bolts of the metric equivalent.

Filter

Base

Inlet Drain

Valve (not

Supplied) figure 3. Inlet water plumbing

Incoming

Water

Supply

Inlet water plUmbInG

It is recommended that the inlet water plumbing line be

1” NPT or larger. A shutoff valve (not supplied) should be installed in the line leading to the system. The valve should be mounted close to the system inlet and sized properly for the inlet plumbing line.

It is also recommended that a “T” or cross Fitting (with cap or plug) be installed between the inlet valve and the system Inlet. This fitting can be used for draining and sanitizing the system and downstream plumbing.

The system should only be connected to the cold water line.

To ensure that the highest quality water is produced from the system, the plumbing leading to the filter system must be flushed clear of all debris before the system is hooked up. Before making the connection to the inlet of the filter system, hold a bucket or other container at the inlet water line and slowly open the inlet water valved. Allow the pipe to flush until all debris is removed.

permeate lIne plUmbInG

To ensure the highest quality and safest water, it is recommended that a check valve (to prevent backflow) be installed in the water line after the permeate connection. This will help prevent possible contamination of the filter system due to other equipment downstream.

The check valve (not supplied) should be mounted close to the system outlet, and sized properly for the plumbing line. Check with local codes for the proper specification.

A shutoff valve (not supplied) should be installed in the filtered water line leading from the system. The valve should be mounted close to the system outlet and sized properly for the plumbing line. This valve will allow for easier servicing and future cartridge change out.

8 P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

UFL-420/440 water FiLtration system

InstallatIOn (continued)

DraIn lIne plUmbInG

The drain line is used to flush away the particle buildup when cleaning the filter. The drain line must be able to support the flow rate when the system flushes. The flow rate from the flush depends on the inlet water pressure, inlet pipe size, and system selected. It is recommended that the drain line be as large as, or larger than, the inlet plumbing line. The drain line should be as short as possible, sloping downward without kinks or loops. Be sure that the drain used is not blocked or restricted.

The filter system must be protected from possible back contamination by the installation of an air gap between the drain connection of the system and the drain

(Figure 4). This gap in the line, with no physical contact between the system and sewer, prevents contamination of the system in the event of a backed-up sewer. nOte: make sure that the end of the drain line is positioned and secured at least 2 inches above the drain so that the water flow is directed into the drain, without splashing.

caUtIOn

Ingesting the protective solution may cause irritation of the gastrointestinal tract, colic, diarrhea, or other similar symptoms

1. Plug the power cord into the appropriate electrical outlet. The unit will power on and the LED display will display the following for about two seconds each:

8.8

fD followed by its time settings in seconds

fi and its time setting in minutes or hours.

fD and fi sequence repeats for about 20 seconds after which the switches to Flush Mode ( fl) before returning to the Flush Interval Mode ( fi).

The time setting for f1 will be displayed and the decimal point will flash in one second intervals.

2. open the tap or faucet closest downstream to the filter system.

Ufl cartrIDGe 3. Slowly open the inlet water valve and allow water to enter the system.

ImpOrtant commonwealth of massachusetts plumbing code

248 cmr shall be adhered to. the use of saddle valves are not permitted, please consult your local plumber.

The cartridge is already installed into the housing. If you need to remove the cartridge, follow the instructions on page 14 in the Changing the Cartridges area of the Maintenance section in this manual. Make sure that all o-rings are lubricated with a food-grade silicone lubricate before assembling

4. Press and hold the Program button. After 6-7 seconds, the drain valve will open and f1 will appear on the display.

5. Continue holding the Program button down for at least 60 seconds to keep the drain valve open.

This flushes air out of the center of the hollow fibers. The drain will remain open as long as the

Program button is pressed. Check to make sure that the drain water is directed into the drain without splashing.

flUsHInG tHe system

To ensure that the highest quality water is produced from the system, the plumbing leading from the filter system must be flushed clear of all debris after the system is hooked up. After making the connection to the outlet of the filter system, open a faucet or tap closest to the filter system, then slowly open the inlet water valve. Allow the pipe to flush until all debris is removed.

6. Release the Program button. This closes the drain valve. Water should continue to flow through the system and out of the open tap.

Allow water to flow out of the tap for at least 15 minutes at maximum flow rate.

7. Close the tap and let the system stand without water flow for 15 minutes to allow any trapped air to come out of the hollow fibers. Check for leaks at all fittings.

The unit also must be flushed to remove air and the shipping/storage solution. For maximum quality, the permeate water produced during the flushing procedure must be discarded. Direct this permeate water to drain.

8. After 15 minutes without water flow, open the tap for 5 minutes to allow any trapped air to be flushed out. Close the tap.

P/N 1010873 Rev. G 03/12 9

UFL-420/440 water FiLtration system A.J. Antunes & Co.

InstallatIOn (continued)

9. once again, press and hold the Program button for at least 60 seconds to flush out any remaining air from the system.

5. Press and hold the Program button to help drain the system.

10. Release the Program button. Flushing is complete.

sanItIzInG tHe system anD lInes

6. When the water flow out of the inlet fitting stops, close the inlet drain valve and pour the liquid bleach into the inlet connection fitting. Be careful not to spill bleach onto clothing or skin. You may want to add the bleach using a cup. Reattach the cap on the fitting.

The plumbing must be sanitized to eliminate possible contamination that may have occurred during the installation process. Chlorine bleach can be used to sanitize the plumbing. The amount of bleach to use depends on the system installed and the amount of plumbing downstream of the filter system. Generally, one ounce (30 ml) of bleach will be sufficient to sanitize the system.

1. Make sure that the system has been flushed of air and debris as described in the Flushing and

Starting up the System section of this manual.

2. open the tap closest downstream to the filter system.

6. Slowly open the inlet water valve and allow water to flow out of the tap until the smell of bleach is present.

7. Close the tap and let the system stand with no water flow for at least 15 minutes to allow the bleach to sanitize the pipes.

8. After 15 minutes without water flow, open the tap and flush until the presence of bleach is gone. All other taps should be opened to flush any bleach from the plumbing. Close the taps.

3. Close the inlet water valve and allow the system to depressurize.

9. Press and hold the Program button for at least 60 seconds to complete the flushing process.

4. Place a bucket under the “T” or cross fitting at the inlet connection to the system. open the inlet drain valve or unscrew the cap to drain the system.

10. Sanitation is complete.

Program the timer following the procedure outlined in the operation section of this manual.

secure end

Drain

Drain line from system

2” (5.1 cm) minimum standpipe secure end

Drain line from system figure 4. proper Draining

10

2” (5.1 cm) minimum floor

Drain

P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

UFL-420/440 water FiLtration system

OperatIOn filtration process

Water filtration in the UFL Series is accomplished using two modes:

starting the system

Power up the unit.

• Flush Interval ( fi on the LED display)

• Flush Duration ( fd on LED display).

The LED read-out displays the following for about two seconds each:

During the Flush Interval mode, water enters the inlet and flows through the filter element before exiting the

Permeate outlet as usable product water. After a certain period of time, depending upon water quality, the filter has to be cleaned. This is accomplished through the Flush Duration Mode. During this mode, the drain valve opens and flushes the membrane to remove debris collected inside the membrane walls.

1. 8.8

2. fd followed by its time settings in seconds.

3. fi and its time setting, in minutes or hours.

fd and fi sequence repeats for 30 seconds

after which, the unit automatically returns to the

Flush Interval Mode ( fi). The time setting for fi

will be displayed and the decimal point will flash in

one second intervals. nOte: both the flush Interval mode and the flush

Duration mode can be automated by programming the timer. During the flush Interval mode, the valve is not powered in order to keep water filtering during a power outage.

nOte: the timer can be programmed immediately after start-up or while in flush Interval mode.

leD Display

fi - Flush Interval Mode is the time between flushings

and is displayed in minutes or hours.

fd - Flush Duration Mode is the amount of time used

to flush and remove debris from filter cartridge and

is displayed in seconds.

fl - Manual Flush Mode operation, solenoid is

manually activated by the user.

PROGRAM figure 5. leD Display, front panel

P/N 1010873 Rev. G 03/12 11

UFL-420/440 water FiLtration system A.J. Antunes & Co.

OperatIOn (continued) programming timer During startup

nOte: Once the unit is powered up, the leD display cycles through the default or current settings: flush Duration (fd) and its setting will be followed by flush Interval (fi) and its settings. at any time during this sequence, which lasts approxi-

mately 30 seconds the unit can be programmed.

setting the flush Interval (fi)

1. When Fi (Figure 5) is displayed, press and release the Program button to view current setting .

PROGRAM figure 6. leD Display for flush Interval mode

2. To make a change, press and hold the Program button to scroll through settings - release the button at desired setting (Figure 5).

3. The unit automatically returns to the Flush

Interval Mode if the Program button is not pressed within 10 seconds..

nOte: fi times are displayed in ten minute intervals, after fifty minutes they are displayed in hours

(table a).

22

PROGRAM figure 7. time setting fi mode (22 Hours)

setting flush Duration (fD)

2. When Fd is displayed, press and release the

Program button to view current setting (Figure 8).

3. To make a change, press and hold the Program button to scroll through settings - release the button at desired setting (Figure 9).

4. The unit automatically returns to the Flush

Interval Mode if the Program button is not pressed within 10 seconds.

nOte: fd times are displayed in 5 second intervals up to 60 seconds (table a).

PROGRAM figure 8. leD Display for flush Duration mode fi - flush Interval mode

1-

5-

10 minutes

50 Minutes

01 1 Hour

12 12 Hours

24 24 hours fd - flush Duration mode

5

10

15

30

5 seconds

10 seconds

15 Seconds

30 Seconds

60 60 Seconds

55

PROGRAM table a. leD Display settings

12 figure 9. time setting fd mode (55 seconds)

P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

UFL-420/440 water FiLtration system

OperatIOn (continued) programming timer while Unit is in flush

Interval (fi) mode

tO set fi - flUsH InterVal mODe nOte: after power-up and cycling - fi time setting displays a flashing decimal point.

1. Press and hold the Program button for four seconds. Release the button and the LED will display fd followed by its setting.

2. When fi (Figure 10) is displayed, press and release the Program button to view current setting.

3. To make a change, press and hold the Program button to scroll through settings - release the button at desired setting (Figure 11).

4. The unit automatically returns to the Flush

Interval Mode if the Program button is not pressed within 10 seconds.

nOte: fi times are displayed in ten minute intervals, after fifty minutes they are displayed in hours

(table b).

tO set fD - flUsH DUratIOn mODe

1. Press and hold the Program button for four seconds. Release the button, the LED displays

fd.

2. When fd is displayed (Figure 12), press and release button to view current setting .

PROGRAM figure 10. fi - leD Display for flush Interval mode

3-

PROGRAM figure 11. time display for fi mode (30 minutes)

3-

PROGRAM figure 12. leD Display for flush Duration

15

3. To make a change, press and hold down start button to scroll through settings - release button at desired setting (Figure 13).

PROGRAM

4. After ten seconds, if start button is not pressed unit automatically returns to Flush Interval Mode.

nOte: fd times are displayed in 5 second intervals up to 60 seconds (table b).

Fi - Flush Interval Mode

1- 10 minutes

5- 50 Minutes

Fd - Flush Duration Mode

5

10

5 seconds

10 seconds

01 1 Hour

12 12 Hours

24 24 hours

15

30

15 Seconds

30 Seconds

60 60 Seconds table b. leD Display settings

P/N 1010873 Rev. G 03/12 13 figure 13. time Display for fd mode (15 seconds)

manual flushing

nOte: manual flushing only works when unit is in flush Interval mode (fi).

While the unit is in Flush Interval Mode (decimal point flashing), hold the Program button down for 6-7 seconds until the LED displays fl (Figure 14). Continue holding the button down to keep the drain open. Drain will remain open for as long as Program button is depressed. ( fl will flash on LED.) Releasing the button closes the drain and puts the unit back into startup mode. After ten seconds, if the Program button is not pressed the unit automatically returns to the Flush Interval

Mode ( fi).

UFL-420/440 water FiLtration system A.J. Antunes & Co.

checking the timer program maIntenance

The filtration system is designed to require very little maintenance. To ensure that the water is of the highest quality, occasionally some service is required.

6. Unplug the system.

7. make sure there is enough room below the housing to remove the cartridge.

During normal operation, the system displays the time setting for the Flush Interval Mode ( fI) and the decimal will flash in one second intervals. This is the time between flushing, not a time of day setting.

8. Remove the snap ring on the end of the housing.

Grab the raised lug with your fingers or a pair of pliers and pull towards the center of the end cap and away. The ring should lift out of its groove.

over time, it is possible that the time that the system flushes occurs at a time of high water use. If this creates a problem, the timer can be reset by unplugging the power cord, waiting for 5 seconds, and plugging the power cord in again. The timer then begins timing from the point power is restored to the system. Follow the procedures within the operation section of this manual to check and set the timer settings.

changing the cartridges

9. The end cap, end cap o-ring, and cartridge should easily drop down out of the housing. If not, pull gently on the end cap to remove.

10. Inspect the cartridge o-rings and end cap o-ring for nicks or cuts. Replace as needed.

11. Lubricate all o-rings with a food-grade silicone lubricant. Apply a light coating of lubricant to the inside center tube at both ends of the new cartridge..

While the filtration system is designed for long life, eventually the cartridges will need to be replaced.

nOte: Do nOt operate the system without the flow regulator assembly or the unit will be damaged, physical injury may occur, and the warranty will be voided.

1. open the faucet or tap closest downstream to the filtration system.

12. Place the end cap o-ring on the end cap and insert the end cap into the end of the new cartridge. Position the new cartridge and end cap below the housing and gently insert into the housing. Press the end cap into position until the end cap is fully seated and the snap ring groove is visible.

2. Close the inlet water valve and allow the system to depressurize.

13. Install the snap ring by guiding the non-lugged end into the groove first, pushing outward and working around the ring until it snaps into place.

3. Place a bucket under the “T” or cross fitting at the inlet connection to the system. open the valve or unscrew the cap to drain the system.

nOte: make sure that the snap ring is fully seated before turning the water on.

4. Press and hold the Start button to help drain the system.

14. Follow the Flushing and Starting the System and

Sanitizing the System and Lines procedures in the

Installation section of this manual to complete the cartridge change.

5. Close the inlet drain valve or reattach the cap on the “T” fitting when the water flow stops.

If the cartridge does not easily come out of the housing, the opposite end cap can also be removed for assistance during Step 8. Remember to inspect and reinstall the o-rings at each end in the proper order.

FL

PROGRAM figure 14. manual flush

system sanitization

over time and use, the plumbing downstream from the system may require sanitization. It is recommended that the system and downstream plumbing be sanitized at least once a year. When necessary, follow the Sanitizing the System and Lines procedure in the

Installation section of this manual.

14 P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

UFL-420/440 water FiLtration system

trOUblesHOOtInG problem

Unit does not have power.

possible cause

The power cord is not correctly plugged in.

corrective action

Plug power cord in correctly.

The Control Display is blank.

The power cord is not correctly plugged in.

Control Board is inoperable.

Transformer is inoperable.

No water comes out of the filter system

Low water flow/pressure out of system

Inlet Valve closed

Inlet Strainer is plugged

End of the capillaries plugged

See above.

Water tastes bad.

Plug power cord in correctly.

Contact your maintenance person or

Authorized Service agency.

open the Inlet Valve

Clean/replace Inlet Strainer

Clean/replace Filter Cartridge

See above.

The system may be in a flush cycle.

Wait for the flush cycle to end.

Flushing program not set correctly for water conditions.

Decrease the flush interval and increase the flush duration (refer to the operation section of this manual).

Drain Valve is stuck open.

Storage/shipping solution not completely flushed out of system.

Replace/rebuild the Drain Valve.

The inlet water pressure is too low.

Boost the inlet water pressure/replace pipes.

Flush system for a longer period of time.

Flush runs continuously.

Flush runs too long.

Flush occurs at time of high water usage.

Biological growth in pipes.

Sanitize plumbing.

Water conditions changed.

Consider installing taste and odor filtration.

Broken capillary in Filter Cartridge.

Replace Filter Cartridge.

Drain Valve stuck open.

Controller sending continuous signal to valve.

Program duration set too long.

Replace/rebuild the Drain Valve.

Replace the controller.

The Flush Interval is set to interfere with water use.

Drain line not positioned properly.

Re-program the unit to flush for a shorter duration of time.

Change Flush Interval/reprogram time.

Unplug unit and plug in at a time of lower water usage.

Reposition the end of the drain line.

Water splashes at drain during flush.

Water leaks at the ends of the

Filter Cartridge after changing cartridges.

Tighten with wrench if necessary.

Water leaks from Permeate port.

Water leaks from system fitting or connection.

Cartridge end connections are not tight enough.

o-rings not lubricated.

o-rings are split, cut, or twisted

Permeate port is not tight enough o-ring not lubricated.

o-ring split, cut, or twisted.

Fitting broken or loose.

Not enough pipe thread sealant used.

Lubricate o-rings with food-grade lubricant.

Replace o-rings.

Tighten, with wrench if necessary.

Lubricate o-ring with food-grade lubricant.

Replace o-ring.

Retighten or replace the fitting.

Redo the fitting with the proper amount of sealant.

P/N 1010873 Rev. G 03/12 15

UFL-420/440 water FiLtration system

wIrInG DIaGram

POWER

CORD

W/24V XFORMER

A.J. Antunes & Co.

NOTE: ALL WIRES TO BE 16 GA. AWM-105°C

UNLESS OTHERWISE SPECIFIED.

14 GA. AWM-105°C

22 GA. AWM-105°C

WHT

TERMINAL

BLOCK

BLK

CONTROL

BOARD

T2

T3

T4

BLK

RED

SOLENOID

VALVE

16 P/N 1010873 Rev. G 03/12

4

A.J. Antunes & Co.

UFL-420/440 water FiLtration system

replacement parts Ufl-420/440 (continued) replacement parts can be purchased from an authorized dealer. contact antunes filtration technologies at 1-630-754-1000 or toll free in the

United states at 1-800-253-2991

1

3

28

6

5

17

13

2

7 10

15

14

22 21

19 16

8

12

9

25

28

24

23

20

5

26

4

P/N 1010873 Rev. G 03/12

27

17

NOTE: Item 12 is GREEN and rated at 5 GPM for UFL-420 units. For UFL-440 units, it is BLACK and rated at 10 GPM.

WARNING: Use only a 5 GPM Flow

Regulator with UFL-420 units and a

10 GPM Flow Regulator for UFL-440 units.

Use of the wrong Flow Regulator will void the system warranty.

UFL-420/440 water FiLtration system A.J. Antunes & Co.

replacement parts Ufl-420/440 replacement parts can be purchased from an authorized dealer. contact antunes filtration technologies at 1-630-754-1000 or toll free in the United states at 1-800-253-2991

Item part

no.

Description Qty.

1 2190150 Union Assembly 1” NPT 1

2 2190144 Nipple, hex 3/4” NPT x 1 1/2” Lg 1

3 2180181 Ring, Lock 2

4 7000442 end cap Kit Incl. 1 of P/N 7000413, 1

1 of P/N 2180181, and

1 of P/N 2180228

5 7000413 o-ring Replacement Kit 1

Incl. 4 of PN 0200236, 2 of

PN 0200235, and 1 of PN 2140153

6 7000411 cartridge Replacement Kit

UFL-420 only (Includes o-ring

Replacement Kit P/N 7000413)

7000412 cartridge Replacement Kit

UFL-440 only (Includes o-ring

Replacement Kit P/N 7000413)

7 0504065 clamp, 4” Filter

1

1

8 308P157 Screw, Tap #8-32 x 3/8” **

9 2180201 Housing, Filter UFL-420

2180202 Housing, Filter UFL-440

10 4040183 Solenoid Valve 24 VAC

Nc 3/4” NPT

12 0021338 Flow Regulator Assembly ***

5 gPM - UFL-420 (green)

0021337 Flow Regulator Assembly ***

10 gPM - UFL-440 (Black)

13 0504033 Bracket, Mounting

14 0400334 Strain Relief - Small

15 040P333 Nut, Lock **

1

1

1

12

1

1

1

1

1

1

Item part

no.

Description

16 0503983 Control Housing

17 0700665 Power Supply, 120 V (5-20P)

0700666 Power Supply, 230 V (CEE 7/7)

0700682 Power Supply, 220 V (hKh-01)

China only

19 4060355 Terminal Block, 3-Pole

20 306P101 Nut, hex #6-32 **

21 308P143 Nut, hex KePS #8-32**

22 304P105 Nut, hex KePS #4-40 **

23 7000440 Timer, 24 VAC

24 7000359 cover gasket Kit

25 7000362 control housing cover Kit

Incl. Items 23 and 25

26 1001116 Label, Timer

27 2190148 Plug, Pipe 1” NPT

28 2190147 Nipple, hex 1” NPT

33* 2140153 Lubricant, high-vacuum grease

34* 0700636 Wire Set

35* 0700637 Wire harness

36* 1001143 Label, Wiring Diagram

37* 1001133 Label, Inlet **

38* 1001135 Label, Drain **

39* 1001134 Label, Permeate **

40* 1010873 owner’s Manual

Qty.

1

1

1

2

4

1

2

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

* not shown

** only available in packages of 10.

*** warninG: Use only a 5 GPm Flow regulator with UFL-420 units and a 10 GPm Flow regulator for UFL-440 units. Use of the wrong Flow regulator will void the system warranty.

18 P/N 1010873 Rev. G 03/12

A.J. Antunes & Co.

UFL-420/440 water FiLtration system

nOtes

P/N 1010873 Rev. G 03/12 19

lImIteD warranty

Equipment manufactured by Antunes Filtration Technologies, a Division of A.J. Antunes & Co., has been constructed of the finest materials available and manufactured to highest quality standards. These units are warranted to be free from defects in material and workmanship for a period of on year from date of purchase under normal use and service, and when installed in accordance with the manufacturer’s recommendations.* The ultra filtration membrane cartridge is warranted under the same terms and conditions on a pro rated basis for 24 months form date of purchase.

*To ensure continued proper operation of the units, follow the maintenance procedure outlined in the owner’s

Manual.

1. This warranty does not cover failures due to improper system installation, defects caused by improper storage or handling prior to placing of the equipment into service.* This warranty does not include overtime charges or work done by unauthorized service agencies or personnel. This warranty does not cover normal maintenance, calibration, or regular adjustments as specified in operating and maintenance instructions of this manual, and/or labor involved in moving adjacent objects to gain access to the Equipment.

2. Antunes Filtration Technologies reserves the right to make changes in design or add any improvements on any product. The right is always reserved to modify equipment because of factors beyond our control and government regulations. Changes to update equipment do not constitute a warranty charge.

3. If shipment is damaged in transit, the purchaser should make a claim directly upon the carrier. careful inspection should be made of the shipment as soon as it arrives and visible damage should be noted upon the carrier’s documentation. Damage should be reported to the carrier. this damage is not covered under this warranty.

4. ThIS WARRANTy IS excLUSIVe AND IS IN LIeU oF ALL oTheR WARRANTIeS, exPReSSeD oR IMPLIeD,

INcLUDINg ANy IMPLIeD WARRANTy oR MeRchANTABILITy oR FITNeSS FoR A PARTIcULAR PUR-

PoSe, eAch oF WhIch IS heReBy exPReSSLy DIScLAIMeD. The ReMeDIeS DeScRIBeD ABoVe ARe

ExCLUSIVE AND IN No EVENT SHALL ANTUNES FILTRATIoN TECHNoLoGIES BE LIABLE FoR SPECIAL coNSeqUeNTIAL oR INcIDeNTAL DAMAgeS FoR The BReAch oR DeLAy IN PeRFoRMANce oF ThIS

WARRANTY.

A.J. Antunes & Co.

Headquarters/Manufacturing

180 Kehoe Boulevard

Carol Stream, Illinois 60188 USA

Phone (630) 784-1000

Toll Free (800) 253-2991

Fax: (630) 784-1650 www.ajantunes.com

Antunes Equipment

Manufacturing (Suzhou) Ltd.,

9 Hou Ju Road, Building #24,

S&T Park, SND

Suzhou, Jiangsu, China 215011

Phone: 86-512-6841-3637

Fax: 86-512-6841-3907

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Reduces cysts and turbidity for clean drinking water
  • Utilizes NeoH capillary membranes for advanced filtration
  • Reusable surface filtration technology for cost-effectiveness and sustainability
  • Programmable timer for automatic flushing and sanitization
  • LED display for easy monitoring and operation
  • NSF/ANSI Standard 42 and 53 certified for quality assurance

Related manuals

Frequently Answers and Questions

What types of contaminants does the Vizion UFL-440 Series remove?
The system effectively reduces cysts and turbidity, meeting NSF/ANSI Standard 42 and 53 requirements for clean and safe drinking water.
How often should I change the filter cartridges?
The suggested replacement period for cartridges is approximately 3 years, ensuring optimal filtration performance.
Can I manually flush the system?
Yes, the system allows for manual flushing to maintain cleanliness and prevent buildup.