indian council of agricultural research, new delhi tender and

indian council of agricultural research, new delhi tender and

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH, NEW DELHI

TENDER AND CONTRACT DOCUMENT

FOR

“SUPPLY, INSTALLATION, INTEGRATION, TESTING &

COMMISSIONING OF AUDIO VISUAL AND CONFERENCING

SYSTEM FOR AUDITORIUM AT NASC COMPLEX, PUSA, NEW

DELHI”

TECHNICAL BID

(Part-I)

June-2017

Tender No.:

RITES/CP/ICAR/AUDI/AV/2017

RITES LIMITED

CP DIVISION, 3

RD

FLOOR

RITES BHAWAN-II, PLOT NO.144

SECTOR-44, GURGAON-122003, HARYANA, INDIA

Tel – 0124-2728305, 307, 309 , Fax – 0124- 2571660

Page 1 of 145

RITES LTD.

TENDER AND CONTRACT DOCUMENT

CONTENTS

S.No. Details Page

PART – 1 (Technical Bid)

SECTION No 1

SECTION No 2

SECTION No 3

SECTION No 4

SECTION No 5

SECTION No 6

(Read with correction slip No. 1 to 5 of e-tendering)

Notice Inviting Tender and Instructions to

Bidders.

Tender and Contract Form

5-54

DELETED

Special Conditions

Schedules A to F

Technical Specifications

Drawings

56-58

59-67

68-97

98-145

PART – 2

(Financial Bid)

SCHEDULE (BILL) OF QUANTITIES

ITEM RATE TENDER ABSTRACT OF COST OF ALL

SCHEDULES

DETAILS OF QUOTED UNIT RATES

AND AMOUNT

PART -3 General Conditions of Contract *

SECTION No 7

SECTION No 8

SECTION No 9

SECTION No 10

Conditions of Contract

Clauses of Contract

RITES Safety Code

RITES Model Rules for Protection of

Health and Sanitary Arrangements for

Workers

SECTION No 11 RITES Contractor‟s Labour Regulations

*General Conditions of Contract 2016 (Compilation of Sections 7 to 11) is available with all correction slips upto date, in RITES website www.rites.com

Page 2 of 145

PART – 1 (TECHNICAL BID)

Page 3 of 145

Page 4 of 145

SECTION-1

NOTICE INVITING TENDER AND

INSTRUCTIONS TO TENDERERS

Page 5 of 145

SECTION 1

NOTICE INVITING TENDER AND INSTRUCTIONS TO TENDERERS

1.0 GENERAL

1.1 Tender Notice

Tenders are invited through E-Tendering system by RITES Ltd., a Public Sector Enterprise under the Ministry of Railways, acting for and on behalf of “

Indian Council of Agricultural

Research (ICAR)”

(Employer) as an Agent / Power of Attorney Holder, from working contractors (including contractors who have executed works within the last five years reckoned from the scheduled date of opening of tender) of Railways, CPWD, MES, DOT,

RITES, State PWD or any other Central / State Government Undertaking, Municipal Body,

Autonomous Body of Central/State Governments or Public Ltd., Companies listed on Stock

Exchange in India or Abroad for the work of “Supply, Installation, Integration, Testing

& Commissioning of Audio Visual And Conferencing System For Auditorium At

NASC Complex, Pusa, New Delhi ”.

(Note: Throughout these bidding documents, the terms „bid‟ and „tender‟ and their derivatives are synonymous).

1.2 Estimated Cost of Work

The work is estimated to cost Rs. 10.69 Crores (Rupees Ten Crores and Sixty Nine lacs

only). This Estimate, however, is given merely as a rough guide.

1.3 Time for Completion

The time allowed for completion will be 05 (five) months from the date of start which is defined in Schedule F under Clause 5.1(a) of Clauses of Contract.

1.4 Brief Scope of Work: a) Supply, transportation, loading and unloading, Transit Insurance, Delivery at site,

Installation, Integration Cabling, Testing, Commissioning, Documentation, Warranty and

Service support of all the components supplied under this contract including Audio, Video

Conferencing, Software, Systems & various components as per Technical Specifications and Bill of Quantities attached to the bidding document and any other work to complete the system as per detail.

b) IT related system, if any, provided for operation with AV equipment (e.g. Video Production equipment / software etc.), the same should be provided with Pre installed OS Software with latest service pack with original DVD Media, license and installation/activation keys.

The Operating System DVD shall be used for installation of the OS in case of software corruption, hard disk replacement etc. Additional software, if any, supplied should be provided with media.

c) Recovery/Reinstallation DVD containing software device drivers etc. for all AV equipment including but not limited to Video Production Systems, Touch Panel and Control Software

Program etc. shall be provided.

Page 6 of 145

d) To the extent possible molded AV cables should be used with the AV equipment. In case

AV connectivity cables are crimped, the cables and connectors shall be of unsoldered type.

1.5 Availability of Site

The construction of auditorium is under progress and working front at site is available. The successful bidder is required to co-ordinate with RITES/other contractors for smooth functioning at the on-going work site.

1.6 Deadline for submission of bids:

11.00 Hrs on 14.07.2017.

The Employer may extend the deadline for submission of Tenders by issuing an amendment in writing in accordance with Clause 6.3 in which case all rights and obligations of the

Employer and the Tenderer previously subject to the original deadline will be subject to new deadline.

1.7 Date & Time of opening of bids:

11.30 Hrs on 14.07.2017.

1.8 Pre-bid Clarification Start time & date:

10.00 Hrs on 24.06.2017.

Pre-Bid Conference: The pre-bid conference will be held at

15:30 Hrs. on 05.07.2017

at

3rd Floor, RITES Office Complex –II, RITES BHAWAN , No-144, Sector-44, Gurgaon-

122003. All prospective bidders are requested to attend the aforesaid pre-bid conference.

1.9 Pre-bid Clarification End Time & date: 15.30 Hrs on

05.07.2017.

2.0 QUALIFICATION CRITERIA TO BE SATISFIED

2.1

The Qualification Criteria to be satisfied are given at Annexure I enclosed .

2.2 The Qualification Criteria to be satisfied will depend on the category of works, whether

Small, Normal or Large. Small Works are those costing upto and including Rs. 3 Crores.

Normal Works are those costing above Rs. 3 Crores and upto & including Rs.100 Crores each and Large Works are those costing more than Rs.100 Crores. The work for which the

Tender is being invited falls under the category of Small*/Normal*/ *Large.

(* Strike out whichever is not applicable)

2.3 The Qualification Criteria to be satisfied will also depend on whether the Work falls in

Normal area or Difficult area. Difficult area includes North East States, Jammu & Kashmir,

Andaman & Nicobar Islands and the 60 districts requiring Integrated Action Plan of

Government of India (List available at Annexure X). Normal area covers all areas other than difficult area. The work for which this Tender has been invited falls under *Normal /

*Difficult area.

(*Strike out whichever is not applicable

)

2.4 In this Tender Joint Venture is * allowed / *not allowed.

(*Strike out whichever is not applicable; In case JV is not allowed, except the first line, the rest of clause 2.4 will be deleted.).

Page 7 of 145

2.5 The documents to be furnished by the Bidder to prove that he is satisfying the Qualification

Criteria laid down should all be in the Bidder‟s name, except in cases where though the name has changed, the owners continued to remain the same and in cases of amalgamation of entities

.

3.0 FORMAT AND CHECK LIST FOR SUBMISSION OF INFORMATION ON

QUALIFICATION CRITERIA

3.1 The information to be furnished and the documents to be enclosed shall be as per Clause

28.0 hereinafter.

4.0 CONTENTS OF TENDER DOCUMENT

4.1 Each set of Tender or Bidding Document will comprise the Documents listed below and addenda issued in accordance with clause 6:

PART – 1 :- Technical Bid Packet

(Read with Correction Slip No. 1 for e-tendering)

Section 1 Notice Inviting Tender and Instructions to Tenderers including Annexures

Section 2 Tender and Contract Form. [DELETED]

Section 3 Special Conditions.

Section 4 Schedules A to F

Section 5 Technical Specifications

Section 6 Drawings

PART – 2 :- Financial Bid Packet

Schedule of Quantities (Bill of Quantities)

PART – 3:- General Conditions of Contract 2016

Section 7

Section 8

Section 9

Conditions of Contract

Clauses of Contract

RITES Safety Code

(read with correction slip Nos. 1 to 2)

Section 10 RITES Model Rules for protection of Health and Sanitary arrangements for

Workers

Section 11 RITES Contractor‟s Labour Regulations

4.2

Part - 3, General Conditions of Contract (Compilation of Sections 7 to 11) as also Correction

Slips to GCC are available on RITES website <www.rites.com> under the link „Tenders‟

4.3 Part 3 of the tender, i.e., General Conditions of Contract 2016 (Compilation of Sections 7 to

11) is not uploaded as a part of this tender document because as stated in sub-clause 4.2 above, the same is available separately on RITES‟ website and can be seen / downloaded from there.

The bidder need not submit / upload Part 3 of the tender as a part of his offer but he must, nevertheless, read the same. It shall be presumed that the bidder has read the contents of

General Conditions of Contract and upto date Correction Slips thereto and the same will be binding upon him. The successful bidder will be required to sign the complete tender document i.e., Part 1, Part 2, Part 3 and Correction Slips, if any, thereto.

5.0 ACCESSING / PURCHASING OF BID DOCUMENTS

Page 8 of 145

(a) To participate in the E–Bid submission for RITES, it is mandatory for the bidders to get their firms registered with E–Procurement portal https://rites.eproc.in

.

(b) Bidder should enroll themselves on the E-Procurement portal by clicking the option “New

Registration” link available on the home page. A Bidder Registration link containing the

detailed guidelines for e-procurement system is available on the RITES E-Procurement portal.

During registration, the bidders should provide the correct/true information including a valid email-id. All correspondence shall be made directly with the contractors/bidders through the email-id provided. The registration charges are INR 4382.04 (Inclusive of Taxes) and this is required to be paid to M/s C1 India Pvt. Ltd. through integrated E–payment gateway. The registration will be approved only after receipt of payments. Validity of registration is for three years. In case of any difficulty faced during registration you are requested to contact e-

Tendering Helpdesk Number provided on E-Procurement portal.

(c) It is mandatory for all bidders to have class – III Digital Signature Certificate (DSC) in the name of the person who will sign the bid from any of licensed Certifying Agency (CA). Bidders can see the list of licensed CAs from the link http://www.cca.gov.in.

(d) Bidders can view / download Part-1 and Part-2 of bid documents from RITES E–Procurement portal https://rites.eproc.in or RITES website http://www.rites.com and Part-3 of the bid documents from RITES website.

(e) Bidder shall ensure use of registered Digital Signature Certificate (DSC) only and safety of the same.

(f) Following may be noted:

Bids can be submitted only during validity of registration of bidder with RITES E–

Procurement portal.

The amendments / clarifications to the bid document, if any, will be posted on E-

Procurement portal / RITES website only.

If the firm is already registered with E–procurement portal of RITES and validity of registration has not expired, the firm is not required for fresh registration.

(g) In case the Digital Signature Certificate (DSC) holder who is digitally signing the bid and the person having Authority to Sign as per Clause 11 are different, even then all the terms and conditions of the tender document will be binding upon the bidder.

5.1 Clarifications on Tender Documents

A prospective Tenderer requiring any clarification on the Tender Document may notify through queries, on line only within the specified period (refer clause 1.8 and 1.9 hereinbefore).

Request for clarifications including request for Extension of Time for submission of Bid, if any, must be received not later than 10 (ten) days prior to the deadline for submission of tenders.

Details of such queries raised and clarifications furnished will be uploaded in RITES website without identifying the names of the Bidders who had raised the queries. Any modification of the Tender Document arising out of such clarifications will also be uploaded on RITES website.

6.0 AMENDMENT OF TENDER DOCUMENT

Page 9 of 145

6.1 Before the deadline for submission of tenders, the Tender Document may be modified by

RITES Ltd. by issue of addenda/corrigendum. Issue of addenda / corrigenda will however be stopped 7 days prior to the deadline for submission of tenders as finally stipulated.

6.2 Addendum/corrigendum, if any, will be hosted on website / E-procurement portal and shall become a part of the tender document. All Tenderers are advised to see the website for addendum/ corrigendum to the tender document which may be uploaded upto 7 days prior to the deadline for submission of Tender as finally stipulated.

6.3 To give prospective Tenderers reasonable time in which to take the addenda/ corrigenda into account in preparing their tenders, extension of the deadline for submission of tenders may be given as considered necessary by RITES.

7.0 PREPARATION AND SUBMISSION OF BIDS

(a) Part-1 and Part-2 of tender document may be downloaded from E–procurement portal of RITES and Part 3 from RITES website, well before the deadline for submission of bids. The bids (Part-

2 only) alongwith the information and documents specified in clause 28 hereinafter, shall be submitted online following the instructions appearing on the screen. Part-1 and Part-3 of the tender document need not be submitted online but it shall be deemed to have been submitted.

Users are requested to map their system as per the System settings available on the link

“System Requirement and Registration Manual” on the E-Procurement portal.

(b) After downloading / getting the tender document/schedules, the Bidder should go through them carefully and then submit the documents as asked, otherwise bid will be rejected. It is construed that the bidder has read all the terms and conditions before submitting their offer.

Bidders are advised that prior to bid submission they should read the Bid Submission manual available on E-Procurement portal on RITES website.

(c) Bidders must ensure that all the pages of the documents mentioned in Clause 28 must be signed & stamped by authorised signatory and serially numbered.

(d) The bids shall be submitted online following the instructions appearing on the screen.

Bidders may insert their eToken/Smart Card in their computer and Log onto E-procurement portal using the User-Id and Password chosen during registration. Then they may enter the password of the eToken/SmartCard to access the DSC.

(e) Prior to bid submission, bidder should get ready with the documents to be uploaded as part of the bid as indicated in the tender document/schedule. Generally they can be in

Excel/PDF/ZIP formats. No other format is accepted. If there is more than one PDF document, then they can be clubbed together in a ZIP file for uploading. Maximum Single file size permitted for uploading is 20 MB. One can upload multiple of such files in case information to be uploaded in single file exceeds 20MB.

(f) Cost of Tender Document & Earnest Money deposit (EMD)

During bid submission the bidder has to select the payment option as offline to pay the cost of tender document and EMD and enter details of the instruments. In case of exemption form payment of cost of tender document and EMD as a matter of Govt. Policy, the scanned copy of document in support of exemption will have to be uploaded by the bidder during bid submission. The onus of proving that the bidder is exempted from payment of cost of tender document and/or EMD lies on the bidder. In this connection, it should be noted that mere opening of bid does not mean that the bid has to be considered by RITES as a valid

Page 10 of 145

bid. If later, it is discovered from the uploaded documents that bidder is not exempted from payment of cost of tender and/or EMD, his bid shall be treated as non-responsive.

Cost of Tender Document: The cost of tender document is Rs. 15,000/- (Rupees Fifteen

Thousand Only) which is non-refundable. It shall be in the form of a Banker‟s Cheque/ Pay

Order/ Demand Draft favoring “RITES Ltd.” issued by a scheduled commercial Bank, payable at Gurgaon / Delhi. No other mode of payment will be accepted.

Earnest Money deposit (EMD) - The bids shall be accompanied by total Earnest Money

Deposit (EMD) of Rs 10.69 lacs (Rupees Ten lacs and Sixty Nine Thousand only) in the form specified in Clause 9 hereinafter.

Upload scanned copy of acceptable instruments for EMD and cost of Tender document in different files (Either in PDF or zip format) during on-line submission of Bid. These documents shall be deposited in “ORIGINAL” in a sealed envelope within a week from the date of opening to:

JGM/Tender Cell , 3

rd

Floor, RITES Office Complex–II, RITES BHAWAN, No.-144,

Sector-44, Gurgaon- 122003.

Failing which the bid shall be rejected and the bidder shall be debarred from tendering in RITES

Ltd. for a period of 02 (two) years, unless the lapse is condoned by the Accepting Authority at the request of the bidder for valid reasons. The envelope should bear the tender details (tender no., tender name etc.).

(g) The bid should be submitted online in the prescribed format. No other mode of submission is accepted.

(h) Bid shall be digitally signed by the Authorized Signatory of the bidder and submitted “on-line”.

No hard copy of the documents (except those specifically asked for in the tender document) are required to be submitted.

(i) The bidders will have to accept unconditionally the online user portal agreement which contains the Terms and Conditions of NIT including General and Special Terms & Conditions and other conditions, if any, along with on-line undertaking in support of the authenticity regarding the facts, figures, information and documents furnished by the Bidder on-line in order to become an eligible bidder.

(j) The bidder has to digitally sign and upload the required bid documents one by one as indicated.

Bidders to note that the very act of using DSC for downloading the bids and uploading their offers shall be deemed to be a confirmation that they have read all sections and pages of the tender/bid document including terms and conditions without any exception and have understood the entire document and are clear about tender requirements which will be binding upon the bidder.

(k) The bidders are requested to submit the bids through online e-tendering system before the deadline for submission of bids (as per Server System Clock displayed on the portal). RITES will not be held responsible for any sort of delay or the difficulties faced during online submission of bids by the bidders at the eleventh hour.

(l) The bidder may seek clarification online only within the specified period. The identity of bidder will not be disclosed by the system. RITES Ltd. will clarify the relevant queries of bidders as far as possible. The clarifications given will be visible to all the bidders intending to participate in that tender. The clarifications may be asked from the day of “Pre Bid Clarification Start Date and Time” till “Pre Bid Query Receipt End Date and Time”.

Page 11 of 145

8.0 TENDER VALIDITY

The Tender shall be valid for a period of 90 days from the due date for submission of Tender or any extended date as indicated in sub para below.

In exceptional circumstances, during the process of evaluation of tenders and prior to the expiry of the original time limit for Tender Validity, the Employer may request that the Tenderers may extend the period of validity unconditionally for a specified additional period. The request and the tenderer‟s response shall be made in writing / e-mail. A Tenderer may refuse the request without forfeiting his Earnest Money. A

Tenderer agreeing to the request will not be permitted to modify his Bid but will be required to extend the validity of the Earnest Money for the period of the extension.

9.0 EARNEST MONEY

9.1

The Tender should be accompanied by earnest money of Rs 10.69 lacs (Rupees Ten lacs

and Sixty Nine Thousand only) (1% of the estimated cost subject to a maximum of

Rs.25 lakhs) in any one of the following forms :

Banker‟s Cheque / Pay Order / Demand Draft issued by any Scheduled Commercial Bank drawn in favour of RITES Ltd. and payable at Gurgaon / Delhi.

9.2 Any Tender not accompanied by scanned copies of the instruments for payment of

Earnest Money and cost of tender document in an acceptable form shall be rejected by the

Employer as non-responsive.

9.3 Refund of Earnest Money

The Earnest Money of the Tenderers whose Technical Bid is found not acceptable will be returned without interest soon after scrutiny of Technical Bid has been completed by the Employer subject to provisions of Clause 9.4 (b). The Earnest Money of the

Tenderers whose Technical Bid is found acceptable but who are neither the lowest nor the second lowest will be returned without interest within 07 days of opening of

Financial Bid. The Earnest Money of the remaining unsuccessful bidders will be released within seven days of the Accepting Authority‟s decision on acceptance or otherwise of the tender subject to provisions of Clause 9.4 (b). The bidder shall submit

RTGS/NEFT Mandate Form as per proforma given in Annexure VII, dully filled in.

9.4 The Earnest Money is liable to be forfeited a) if after bid opening, but before expiry of bid validity or issue of Letter of Acceptance, whichever is earlier, any Tenderer i) withdraws his tender or ii) makes any modification in the terms and conditions of the tender which are not acceptable to the Employer. b) in case any information/document which may result in the tenderer‟s disqualification is concealed by the Tenderer or any statement/information/document furnished by the

Tenderer or issued by a Bank/Agency/third party and submitted by the tenderer, is

Page 12 of 145

subsequently found to be false or fraudulent or repudiated by the said

Bank/Agency/Third Party” c) in the case of a successful Tenderer, if the Tenderer i) fails to furnish the Performance Guarantee within the period specified under Clause 1 of “Clauses of Contract”. or ii) fails to commence the work without valid reasons within the period as specified in Schedule F after the date of issue of Letter of Acceptance or from the first date of handing over of the site, whichever is later.

In case of forfeiture of Earnest Money as prescribed hereinabove, the Tenderer shall not be allowed to participate in the retendering process of the work.

10.0 MODIFICATION/ SUBSTITUTION/ WITHDRAWL OF BIDS

10.1

The Tenderers shall submit offers which comply strictly with the requirements of the

Tender Document as amended from time to time as indicated in Clause 6.0 above.

Alternatives or any modifications by the tenderer shall render the Tender invalid.

10.2 The bidder can modify, substitute, re-submit or withdraw its E–bid after submission but prior to the deadline for submission of bids. No Bid shall be modified, substituted or withdrawn by the bidder on or after the deadline for submission of bids. Withdrawal of bid after the deadline for submission of bids would result in the forfeiture of EMD.

10.3 Any modification in the Bid or additional information supplied subsequently to the deadline for submission of bids, unless the same has been explicitly sought for by RITES, shall be disregarded.

10.4 For modification of E–bid (Technical Bid), bidder has to detach its old bid from E– procurement portal and upload / re-submit digitally signed modified bid.

10.5 For withdrawal of bid, bidder has to click on withdrawal icon at E–procurement portal and can withdraw its E–bid.

10.6 After the bid submission on the portal, an acknowledgement number will be generated by the system which should be printed by the bidder and kept as a record of evidence for online submission of bid for the particular tender and will also act as an entry pass to participate in the bid opening.

10.7 The time settings fixed in the server side & displayed at the top of the tender site, will be valid for bid submission, in the e-tender system. The bidders should follow this time during bid submission.

10.8 All the data being entered by the bidders would be encrypted using PKI encryption techniques to ensure the secrecy of the data. The data entered will not be viewable by unauthorized persons during bid submission & will not be viewable by any one until the date & time specified for bid opening.

Page 13 of 145

10.9 The bidder should logout of the tendering system using the normal logout option available in the portal and not by selecting the (X) exit option in the browser.

11.0 AUTHORITY TO SIGN

a) If the applicant is an individual, he should sign above his full type written name and current address. b) If the applicant is a proprietary firm, the Proprietor should sign above his full type written name and the full name of his firm with its current address. c) If the applicant is a firm in partnership, the Documents should be signed by all the partners of the firm above their full type written names and current addresses.

Alternatively the Documents should be signed by the person holding Power of

Attorney for the firm in the Format at Annexure III. d) If the applicant is a limited Company, or a Corporation, the Documents shall be signed by a duly authorized person holding Power of Attorney for signing the

Documents in the Format at Annexure III. e) If the applicant is a Joint Venture, the Documents shall be signed by the Lead

Member holding Power of Attorney for signing the Document in the Format at

Annexure IV. The signatory on behalf of such Lead Partner shall be the one

holding the Power of Attorney in the Format at Annexure III. [NOT APPLICABLE]

11.1 Points to be kept in mind while preparing the bid

While filling in Qualification Information documents and the Financial Bid, following should be kept in mind: i) There shall be no additions or alterations except those to comply with the instructions issued by the Employer or as necessary to correct errors, if any, made by the Tenderers. ii) Conditional Offer/ Tender will be rejected. Unconditional rebate/ discounts in the

Financial offer will however be accepted. iii) The Employer reserves the right to accept or reject any conditional rebate/discounts. While evaluating the Bid Price, the conditional rebates/discounts which are in excess of the requirements of the bidding documents or otherwise result in accrual of unsolicited benefits to the Employer, shall not be taken into account. iv) In case of Item Rate Tenders, if the same item figures in more than one section/part of Schedule of Quantities, the Tenderer should quote the same rate for that item in all section/parts. If different rates are quoted for the same item the least of the different rates quoted only shall be considered for evaluation of that item in all section/parts of the Schedule of Quantities. v) In case the bidder does not quote his rate for any items(s), it will be presumed that the bidder has included the cost of that/those item(s) in the rates of other items and the rate for such item(s) shall be considered as Zero and the tender will be evaluated by the employer accordingly and the work executed by the successful bidder accordingly. vi) In case of credit items/recovery items/deduction items for which the bidder has to pay the amount to RITES/Employer, the rate quoted by the bidder shall be taken as negative (irrespective of whether the bidder has put a negative sign or not) and the negative amount so calculated shall be considered to work out the total bid amount.

11.2 Integrity Pact

Page 14 of 145

(i) The Bidder/Contractor is required to enter into an Integrity Pact with the Employer, in the Format at Annexure VI. The Integrity Pact enclosed as Annexure VI will be signed by RITES for and on behalf of Employer as its Agent/Power of Attorney

Holder at the time of execution of Agreement with the successful Bidder. While submitting the Bid, the Integrity Pact shall be signed by the duly authorized signatory of the Bidder/Lead Member of JV. In case of failure to submit the Integrity Pact duly signed and witnessed, along with the Bid, the Bid is likely to be rejected.

(ii) In case of any contradiction between the Terms and Conditions of the Bid Document and the Integrity Pact, the former will prevail.

Provided always that provision of this Clause 11.2 – Integrity Pact, shall be applicable only when so provided in Clause 11.2A below which will also stipulate the name and address of the Independent External Monitor as well as the Name, designation and address of the official nominated by the Employer to act as the Liaison Officer between the Independent External Monitor and the Engineer-in- Charge as well as the Contractor.

11.2A Whether Clause 11.2 (Integrity Pact) shall be applicable *YES / *NO

*Strike out whichever is not applicable

If Yes, Name and Address of the Independent External

Monitor (In case estimated cost put to tender is above Rs.10 crores or more)

Shri Suresh Kumar (IRAS),

Ex-Director, CONCOR,

D-401, Rail Vihar Classic Apartment,

Sushant Lok-III, Sector-57, Gurgaon-122003

Name, Designation and Address of RITES‟ Liaison officer

3

Shri Y.K.Sharma,

GGM/ B&A,

RITES Office Complex -II,

rd

Floor, Plot No-144,

Sector-44, Gurgaon-122001.

12.0 TENDER OPENING, EVALUATION AND CLARIFICATIONS

12.1 The Employer will open all the Tenders received, in the presence of the Tenderers or their representatives who choose to attend at

11.30 Hrs. on 14.07.2017

in the office of

JGM/Tender Cell, 3

rd

Floor, RITES Office Complex –II, RITES BHAWAN , No-144,

Sector-44, Gurgaon- 122003. In the event of the specified date of the opening being

declared a holiday by the Employer, the Tenders will be opened at the appointed time and location on the next working day.

12.2 Opening of bids will be done through online process. RITES reserves the right to postpone or cancel a scheduled bid opening at any time prior to its opening. Information of the same will be displayed at RITES E-procurement portal.

12.3 Bid opening committee will open the bids online in the presence of bidders or their authorized representatives who choose to attend on opening date and time. Also the bidders can participate online during the bid opening process from their remote end through their dashboard. The bidder‟s representatives, who are present, shall sign in an attendance

Page 15 of 145

register. RITES shall subsequently examine and evaluate the bids in accordance with the provision set out in the tender document.

12.4 It will be the bidder‟s responsibility to check the status of their Bid on-line regularly after the opening of bid till award of work. Additionally, information shall also be sent by system generated e-mail to bidder regarding deficiencies in the documents, if any and also request for clarification from the bidder. A system generated SMS alert will also be sent to the bidder. No separate communication will be sent in this regard. Non-receipt of e-mail and

SMS will not be accepted as a reason of non-submission of deficient documents or confirmatory documents within prescribed time.

12.5 The bids will be evaluated for qualifying criteria as mentioned in Clause 2 hereinbefore.

RITES shall not be responsible for any postal delay in receipt of all original documents including the cost of tender document and EMD. In case of non-receipt of these documents in original within the aforesaid period, the bid will be treated as non-responsive.

12.6 Two Packet System -APPLICABLE

(a) (i) Envelope 1 containing scanned copy of Earnest Money along with Mandate Form as per

Annexure VII, Cost of Tender Document and scanned copy of Authority to sign document of all the Tenderers will be opened first and checked. If any of the document(s) so furnished are not as per tender stipulations, the Envelope 2 of PACKET A (Technical Bid) and

PACKET B (Financial Bid) will not be opened and the bid is treated as rejected. The

Envelope 2 of PACKET A (Technical Bid) of other Tenderers who have furnished scanned copies of Earnest Money, cost of Tender document and Authority to sign as per tender stipulations will then be opened.

(b) The Employer will scrutinize the Technical Bids accepted for evaluation to determine whether each Tenderer

(i) has submitted „Authority to sign‟ as per Clause 11.0 above and Integrity Pact (where applicable) duly signed and witnessed as per Clause 11.2 above;

(ii) meets the Qualification Criteria stipulated in Clause 2.0; and

(iii) conforms to all terms, conditions and specifications of the Tender Document without any modifications or conditions.

(c) If required, the Employer may ask any such Tenderer for clarifications on his Technical

Bid. If a Tenderer does not submit the clarification/document requested, by the date and time set in the Employer‟s request for clarification, the bid of such Tenderer is likely to be rejected. PACKET B (Financial Bid) of Tenderers whose Technical Bids are not found acceptable will not be opened. Tenderers whose Technical Bids are found acceptable will be advised accordingly and will also be intimated through e-mail the time and date and place where and when the PACKET B (Financial Bid) will be opened.

(d) At the appointed place, time and date, in the presence of the Tenderers or their representatives who choose to be present, the Employer will open the envelopes containing the PACKET B (Financial Bid).

Page 16 of 145

12.7 Single Packet System – NOT APPLICABLE

(a) Envelope 1 containing scanned copy of Earnest Money along with Mandate Form as per Annexure VII, cost of tender document and scanned copy of Authority to sign document of all the Tenderers will be opened first and checked. If any of the document(s) so furnished are not as per tender stipulations, the Envelope 2 of Technical bid and

Envelope 3 containing Financial bid will not be opened and the bid is treated as rejected.

The Envelope 2 containing Technical Bid and Envelope 3 containing Financial Bid of other Tenderers who have furnished scanned copies of Earnest Money, cost of Tender document and Authority to sign as per tender stipulations will then be opened.

12.8 Mere Opening of Bid to be No Guarantee of its Validity

In both Single Packet and Two Packet System, it may be noted that mere opening of a bid does not mean that the bid has to be considered by RITES as a valid bid. All bids will be evaluated to decide whether the bids are responsive or non-responsive.

13.0 INSPECTION OF SITE BY THE TENDERERS

Tenderers are advised to inspect and examine the site and its surroundings and satisfy themselves before submitting their Tenders, as to the assess the extent of work already completed, the balance work, material already available at site for incorporation in works, the nature of work, the nature of the ground and sub-soil (as far as is practicable), the form and nature of the site, the means of access to the site, the accommodation they may require and in general shall themselves obtain all necessary information as to risks, contingencies and other circumstances which may influence or affect their Tender. A Tenderer shall be deemed to have full knowledge of the site whether he inspects it or not and no extra charges consequent on any misunderstanding or otherwise shall be allowed. The Tenderer shall be responsible for arranging and maintaining at his own cost all materials, tools & plants, water, electricity, access, facilities for workers and all other services required for executing the work unless otherwise specifically provided for in the contract documents. Submission of a tender by a Tenderer implies that he has read this notice and all other contract documents and has made himself aware of the scope and specifications of the work to be done and of conditions and rates at which stores, tools and plant etc. will be issued to him by the Employer and local conditions and other factors having a bearing on the execution of the work.

14.0 EMPLOYER‟S RIGHT ON ACCEPTANCE OF ANY TENDER

(i) If required, the Employer may ask any Tenderer the breakdown of unit rates. If the

Tenderer does not submit the clarification by the date and time set in the Employers request for clarification, such Tender is likely to be rejected.

(ii) The competent authority on behalf of the Employer does not bind himself to accept the lowest or any other Tender and reserves to himself the authority to reject any or all the Tenders received without the assignment of any reason. All Tenders in which any of the prescribed conditions is not fulfilled or any condition is put forth by the

Tenderer shall be summarily rejected.

Page 17 of 145

15.0 CANVASSING PROHIBITED

Canvassing whether directly or indirectly, in connection with tenders is strictly prohibited and the tenders submitted by the Contractors who resort to canvassing will be liable to rejection.

16.0 EMPLOYER‟s RIGHT TO ACCEPT WHOLE OR PART OF THE TENDER

The competent authority on behalf of the Employer reserves to himself the right of accepting the whole or any part of the tender and the Tenderer shall be bound to perform the same at the rates quoted.

17.0 MISCELLANEOUS RULES AND DIRECTIONS

17.1

The Tenderer shall not be permitted to tender for works if his near relative is posted as

Associated Finance Officer between the grades of AGM(F) and J.M (F) in the concerned

SBU Unit of RITES or as an officer in any capacity between the grades of GGM/GM and

Engineer (both inclusive) of the concerned SBU of the Employer. He shall also intimate the names of persons who are working with him in any capacity or are subsequently employed by him and who are near relatives to any Gazetted officer in the organization of the

Employer. Any breach of this condition by the Tenderer would render his Tender to be rejected.

No Engineer of Gazetted rank or other Gazetted Officer employed in Engineering or

Administrative duties in an Engineering Department of the Organisation of the Employer 15 is allowed to work as a contractor for a period of one year after his retirement from the

Employer‟s service without the previous permission of the Employer in writing. The contract is liable to be cancelled if either the Contractor or any of his employees is found any time to be such a person who had not obtained the permission of the Employer as aforesaid before submission of the tender or engagement in the Contractor‟s service.

17.2 If required by the Employer, the Tenderers shall sign a declaration under the officials

Secret Act 1923, for maintaining secrecy of the tender documents drawings or other records connected with the work given to them. The unsuccessful Tenderers shall return all the drawings given to them.

17.3 In the case of any Item rate tender where unit rate of any item/items appears unrealistic, such tender will be considered as unbalanced and in case the Tenderer is unable to provide satisfactory explanation, such a tender is liable to be disqualified and rejected.

17.4 Sales-tax/VAT (except Service Tax), purchase tax, turnover tax or any other tax/ Cess on material, labour and Works in respect of this Contract shall be payable by the Contractor and the Employer will not entertain any claim whatsoever in respect of the same. However, in respect of Service Tax, same shall be paid by the Contractor to the concerned department on demand and it will be reimbursed to him by the Engineer-in-Charge after satisfying that it has been actually and genuinely paid by the Contractor.

17.5 Each Bidder shall submit only one Bid either as an individual or as a Proprietor in a

Proprietary firm or as a Partner in a Partnership firm or as a Director of a limited

Company/Corporation or as a Partner in a Joint Venture. Any Bidder who has submitted a

Bid for a work, shall not be a witness for any other Bidder for the same work. Failure to

Page 18 of 145

observe the above stipulations would render all such Tenders submitted as a Bidder and / or as a witness, liable to summary rejection.

17.6 The Contractor shall be fully responsible for all matters arising out of the Performance of the Contract and shall, at his own expense, comply with all laws/ acts/ enactments/ orders/ regulations/ obligations whatsoever of the Government of India, State Government, Local

Body and any Statutory Authority.

17.7 In case the bidder does not quote his rate for any item(s), it will be presumed that the bidder has included the cost of that/those item(s) in the rates of other items and the rate for such item(s) shall be considered as Zero and the tender will be evaluated by the Employer accordingly and the work executed by the successful bidder accordingly.

17.8 In case of credit items/recovery items/deduction items for which the bidder has to pay the amount to RITES/Employer, the rate quoted by the bidder shall be taken as negative

(irrespective of whether the bidder has put a negative sign or not) and the negative amount so calculated shall be considered to work out the total bid amount.

18.0 SIGNING OF CONTRACT AGREEMENT

18.1 The Tenderer whose tender has been accepted will be notified of the award by the Employer by issue of a „Letter of Acceptance‟ prior to expiration of the Bid Validity period.

The Letter of Acceptance will be sent to the Contractor in two copies one of which he should return promptly, duly signed and stamped. The Letter of Acceptance will be a binding Contract between the Employer and the Contractor till the formal Contract

Agreement is executed.

18.2 Within the period as specified in Clause 1 of „Clause of Contract‟, of the date of issue of

Letter of Acceptance, the successful Tenderer shall deliver to the Employer, Performance

Guarantee and Additional Performance Guarantee (where applicable) in the format prescribed.

18.3 The Tenderer whose Tender is accepted shall be required to submit at his cost stamp papers of appropriate value as per the provisions of Indian Stamp Act within 15 days of the date of issue of Letter of Acceptance.

18.4 At the same time the Employer notifies the successful Tenderer that his Tender has been accepted, the Employer will direct him to attend the Employer‟s office within 28 days of issue of Letter of Acceptance for signing the Agreement in the proforma at Annexure V.

The Agreement will however be signed only after the Contractor furnishes Performance

Guarantee and Additional Performance Guarantee (where applicable) and hence, where justified, the period of 28 days stipulated above will be extended suitably.

19.0 Pre Qualification Performa

The bidder shall fill the pre qualification proforma at Annexure IX. The bid will be evaluated only considering those details and corresponding documents as mentioned in

Annexure IX and no other details/ certificate/ document will be taken in to consideration while evaluating the bid to decide whether the bidder is qualified or not. For similar work

Page 19 of 145

experience the details of only those works mentioned in Annexure IX may be given in

Performa no. 1 attached to Annexure-I.

S.

N o.

20.0 Brief Notice Inviting e-Tenders

GM/CP/RITES (Designation of the officer), RITES Ltd invites on behalf of “Indian

Council of Agricultural Research, New Delhi Online item rate/ percentage rate/ item rate

+ percentage rate/ lump sum bids on single/ two packet system for the following work

NIT

No.

Name of work &

Location

Cost of

Tender

Document

Rs.

Estimated

Cost put to bid Rs.

Earnest

Money

Rs.

Period of

Compl etion

Last Date

& time of submission of bid,

EMD, cost of tender document and other

Documents as specified in the press notice

Time

& Date of opening of bid

Page 20 of 145

1 2

1 RITES/

CP/IC

AR/AU

DI/AV/

2017

3

Supply,

Installation,

Integration,

Testing &

Commissioning of Audio Visual and

Conferencing

System For

Auditorium At

NASC Complex,

Pusa, New Delhi

4

15000/-

5 6

Rs . 10.69 crores Rs. 10.69 lacs

7 8

5 months 11.0 hrs on

14.07.2017

9

11.30 hrs on

14.07.2017

21.0 The bid document consisting of tender drawings, specifications, the schedule of quantities of various types of items to be executed and the set of terms and conditions of the contract to be complied with and other necessary documents can be seen on website www.rites.com free of cost.

22.0 After submission of the bid the bidder can re-submit revised bid any number of times but before last time and date of submission of bid as notified.

23.0 While submitting the revised / modified Financial bid, the bidder can revise / modify the rate of one or more item(s) any number of times (he need not re-enter rate of all the items) but before last time and date of submission of bid as notified.

24.0 The bid submitted shall become invalid and e-Tender processing fee shall not be refunded if:

(i) The bidder is found ineligible.

(ii) The bidder does not upload all the documents (including service tax registration/ VAT registration/ Sales Tax registration) as stipulated in the bid document including the undertaking about deposition of physical EMD of the scanned copy of EMD uploaded.

(iii) If any discrepancy is noticed between the documents as uploaded at the time of submission of bid and hard copies as submitted physically by the lowest bidder in the office of bid opening authority.

(iv) The bidder does not deposit physical instruments of EMD within a week of opening of technical bid.

25.0 Those contractors not registered on the website mentioned above, are required to get registered beforehand. If needed they can be imparted training on online bidding process as per details available on the website.

Page 21 of 145

26.0 The intending bidder must have valid Class-III digital signature to submit the bid.

27.0 On opening date, the bidder can login and see the bid opening process. After opening of bids he will receive the competitor bid sheets.

28.0 List of Documents to be scanned and uploaded within the period of bid submission:-

1.

Banker‟s Cheque/ Pay Order/ Demand Draft towards cost of Tender Document in accordance with Clause 7.0 (f) hereinbefore

OR

Document in support of exemption from payment of cost of Tender Document

2.

Banker‟s Cheque/ Pay Order/ Demand Draft and Bank Guarantee in format given at

Annexure VIII towards Earnest Money Deposit (EMD) in accordance with Clause 9 hereinbefore

OR

Document in support of exemption from payment of EMD

3.

Authority to Sign (if required as per Clause 11.0 hereinbefore) in the format given at

Annexure III / Annexure IV as applicable.

4.

Documents in support of meeting the criterion of Annual Financial Turnover in accordance with Para 1 of Annexure I.

5.

Certificates in support of meeting the criterion of Similar Work Experience in accordance with Para 2(a) of Annexure I.

6.

Details of Similar works completed in the format given at Performa 1 in Annexure I.

7.

Certificates in support of meeting the criterion of Construction Experience in key activities / specified components in accordance with Para 2(b) of Annexure I. - DELETED

8.

Solvency Certificate in accordance with Para 3(i) of Annexure I.

9.

Documents (Audited Balance Sheets, Profit & Loss Statements and Auditor‟s Reports) in support of meeting the Profitability criterion in accordance with Para 4 of Annexure I.

10. Documents in support of meeting the criterion of Net Worth in accordance with Para 5 of

Annexure I.

11. Declaration by the Bidder in the format given in Performa 3 of Annexure I.

12. Integrity Pact as per Annexure VI including Annexure A thereof.

13. RTGS/NEFT details as per Annexure- VII

14. Annexure IX duly filled in.

15. Self-attested copy of a certificate, confirming that the applicant is working contractor or has executed any work within the last five years reckoned from the date of opening of tender, issued by Railways, CPWD, MES, DOT, RITES, State PWD or any other Central / State

Page 22 of 145

Government Undertaking, Municipal Body of Central / State Government or Public Limited

Company listed in Stock Exchange in India & Abroad.

16. Self-Attested Copy of Partnership Deed/ Memorandum and Articles of Association of the firm.

17. Self-Attested copy of Corrigendum(s), if any.

18. Any other document if specified in the correction slips to the Tender Document.

19. Self-certified copy of the Joint Venture Agreement/Memorandum of Understanding as per

Annexure II & Annexure IV (where Joint Venture is allowed) - DELETED

20. Power of Attorney in favour of Lead Member as the Lead Member of JV executed by the authorized representatives of all the members of JV (where Joint Venture is allowed). -

DELETED

21. Self-attested copy of a certificate, confirming that the Partners including Lead Partner duly signed by the Authorized representative of each Partner/Member of Joint Venture is a working contractor or has executed any work within the last five years reckoned from the date of opening of Tender, issued by Railways, CPWD, MES, DOT, RITES, State PWD or any other Central/State Government Undertaking, Municipal Body, Autonomous Body of

Central or State Government or Public Limited Company listed on NSE/BSE (where Joint

Venture is allowed). – DELETED

22. Self attested copy of Sales Tax, Woks Contract Tax, Service Tax Registration Certificate (As applicable)

Note: - Any clarification / deficient document(s) sought by RITES Ltd. as per Clause 12.4 &

Clause 12.6 (c) shall be submitted by the bidder.

29.0 List of Documents to be submitted physically by Lowest (L1) Bidder within a week of the opening of Financial Bid:-

1. Self-attested copy of PAN/TAN issued by income Tax Department

2. Self-attested copy of registration under Labour Laws like PF, ESI etc.

3. Self-attested copy of ISO 9000 Certificate. (if any)

4. Self-attested copies of all the documents specified in Clause 28.0 above.

30.0 RITES Ltd. may approach any Bank, Individual, Employer, Firm or Corporation, whether mentioned in the documents submitted by bidders or not, to verify the credentials and general reputation of the bidder and where JV is allowed the credentials and general reputation of lead member & each Member of Joint Venture.

Page 23 of 145

ANNEXURE – I

1.

QUALIFYING CRITERIA FOR WORKS CONTRACTS

Annual Financial Turnover

The bidder should have achieved a minimum annual financial turnover of Rs. 21.38 Crores in any one of the last 3 Financial Years.

Notes:

-

The financial turnover will be taken as given under the head “Income” in audited Profit and Loss Account and excluding non-recurring income, income from other sources and stock. It is clarified that the Financial Turnover means relevant revenue as recorded in the

Income side of Profit and Loss Account. It does not mean Profit.

- Closing stocks in whatsoever manner should not form part of turnover.

-

-

-

-

-

Weightage of 7% (compounded annually) shall be given for equating the financial turnover of the previous years to the current year.

For considering the Financial Years, for example for a work for which the Tender is being opened in Financial Year 2014-15, the last three Financial Years will be 2013-14, 2012-13 and 2011-12. For a Tender opened on (say) 05.09.14 (F.Y. 2014-15), with weightage of

7% compounded annually, the weightages to be applied on the Turnover of the previous three Financial Years will be : F.Y. 2013-14 = 1.070; F.Y. 2012-13 = 1.145; F.Y. 2011-

12 = 1.225.

The Bidder should furnish Annual Financial Turnover for each of the last 3 Financial

Years in tabular form and give reference of the document (with page no.) relied upon in support of meeting the Qualification Criterion.

The Bidder should submit self attested copy of Auditor‟s Report along with Balance Sheet and Profit and Loss Statement along with Schedules for the relevant Financial Year in which the minimum criterion is met. Provisional audit reports or certified statements will not be accepted.

If the Audited Balance Sheet for the immediately preceding year is not available in case of tender opened before 30th Sept., audited Balance Sheets, Profit and Loss Statements and other financial statements of the three Financial Years immediately preceding the previous

Financial Year may be adopted for evaluating the credentials of the Bidder.

-

In case JV is permitted the following provisions will apply:- JV NOT APPLICABLE

Page 24 of 145

2.

WORK EXPERIENCE

a) Similar Works Experience

(i)

For works in normal areas (other than difficult areas)

The Bidder should have satisfactorily completed in his own name or proportionate share as a member of a Joint Venture, at least one similar work of minimum value of Rs.8.

55

Cr. OR at least two similar works each of minimum value of Rs.5.34 Cr. OR at least

three similar works each of minimum value of Rs.4

.27 Cr. during the last 5 (five) years

prior to the last stipulated date for submission of the Bid. Works completed prior to the cut off date shall not be considered.

Or

(ii)

For works in difficult areas (Refer Clause 2.3)

– NOT APPLICABLE

Similar Works

Similar Works shall mean any of the following works mentioned as under:

a) The supply, installation, testing & commissioning of Audio-Video and conferencing system in Institutional Buildings/Auditoriums/Conference Halls etc.

The Work(s) similar to the definition mentioned above should have been satisfactory completed by the bidder anywhere in India in his own name or in the lead member position in Joint venture having its share not less than 51% in last five years prior to stipulated/extended date of submission.

Notes:

- A weightage of 7% (compounded annually from the date of completion of the work to the submission of the Bid) shall be given for equating the value of works of the previous years to the current year.

- Only such works shall be considered where physical completion of entire work is over or commissioning of work has been done, whichever is earlier.

- The Bidder should submit the details of such similar completed works as per the format at

Proforma-1 enclosed.

- Works carried out by another Contractor on behalf of the Bidder on a back to back basis will not be considered for satisfaction of the Qualification Criterion by the Bidder.

- Credential certificates issued by Govt. Organizations / Semi Govt. Organizations of

Central or State Government; or by Public Sector Undertakings/ Autonomous bodies of

Central or State Governments; or by Public Ltd. Companies listed in Stock Exchange in

India or abroad shall only be accepted for assessing the eligibility of a Tenderer.

- The cut-off date shall be calculated backwards from the last stipulated date for submission/ opening of Tender i.e. for a Tender which is being opened on 06.08.2014, the cut-off date shall be 07.08.09.

- In case JV is permitted the following provisions will apply: NOT APPLICABLE

b) Construction Experience in key activities/specified components: NOT APPLICABLE

Page 25 of 145

3.

SOLVENCY CERTIFICATE AND SERVICING OF LOAN / CREDIT LIMIT

(i) A Solvency Certificate of minimum solvency of Rs. 4.27 Crores (suggested format at Proforma 2) from a Scheduled Commercial Bank issued not earlier than

6 months from the last date for submission of tender is required to be submitted by the bidder.

Notes:

-

The certificate so produced by the Bidder may be got verified from the issuing

Bank.

-

In case JV is permitted the following provisions will apply - NOT APPLICABLE

(ii) The bidder should furnish a declaration that he has not failed to service the principal amount or interest or both of a loan amount / credit limit from any Bank or Financial Institution during a period of one year prior to the deadline for submission of bids.

-

Notes:

-

-

In case a bidder has defaulted in servicing his loan / credit limit during past one year, he shall be disqualified.

The declaration may be included in the Declaration to be submitted in Performa 3 to this Annexure.

In case JV is permitted the following provisions will apply - NOT APPLICABLE

4. PROFITABILITY

The Bidder should be a profit (net) making firm and should have made profit during any two of the past 3 Financial Years immediately preceding the deadline for submission of bids. If the audited Balance Sheet for the immediately preceding year is not available in case of tenders opened before 30 th

September, Audited Balance Sheets of the three financial

Years immediately preceding the previous Financial Year shall be considered.

The Bidder should furnish figures of net profit of last 3 years in a tabular form and submit attested copies of Auditor‟s Reports along with audited Balance Sheets and Profit and

Loss Statements for the last three Financial Years. Specific reference with page no. of document which proves satisfaction of this Qualifying Criterion should be indicated in the tabular statement.

Notes:

- In case JV is permitted, the following provisions will apply: NOT APPLICABLE

5. NET WORTH

The Bidder should have positive Net Worth of at least 15% of the estimated cost.

Notes:

- Net Worth shall be computed from the bidder‟s audited balance sheet of the last financial year ending on a date not prior to 18 months from the due date of submission of the tender (or, if the date is extended, such extended date of submission).

- In case JV is permitted, the following provisions will apply: NOT APPLICABLE

Page 26 of 145

6.

POINTS TO NOTE ON SATISFACTION OF QUALIFYING CRITERIA IN CASE

OF BOTH LARGE AND NORMAL WORKS

a) Sub-Contractor‟s Experiences and Resources

Sub-Contractors‟ Experiences and Resources will not be taken into account in determining the Bidder‟s compliance with the qualifying criteria.

b) Experiences and Resources of the Parent Company and other subsidiary companies

If the Bidder is a wholly owned subsidiary of a company, the experience and resources of the owner/parent company or its other subsidiaries will not be taken into account. However, if the Bidder is a Company, the Experience and Resources of its subsidiaries will be taken into consideration .

7. DISQUALIFICATION ON CERTAIN GROUNDS

Even though the Bidders may meet the above qualifying criteria, they are subject to be disqualified if they have a) Concealed any information/document which may result in the Bidder‟s disqualification or if any statement/information/document furnished by the Bidder or issued by a Bank/Agency/third party and submitted by the Bidder, is subsequently found to be false or fraudulent or repudiated by the said Bank/Agency/Third Party. In such a case, besides Bidder‟s liability to action under para 9.4 of Instructions to

Tenderers, the Bidder is liable to face the penalty of banning of business dealings with him by RITES.

b) Records of any contract awarded to them, having been determined during the past three years prior to the dead line for submission of bids.

c) Been declared as Poor Performer by RITES and their name is currently in the „Negative

List‟ of RITES.

d) Their business banned or suspended by any Central/State Government Department/

Public Undertaking or Enterprise of Central/State Government and such ban is in force.

e) Not submitted all the supporting documents or not furnished the relevant details as per the prescribed format.

A declaration to the above effect in the form of affidavit on stamp paper of Rs. 10/-

duly attested by Notary/Magistrate should be submitted as per format given in

Proforma 3 enclosed.

Page 27 of 145

Proforma-1

LIST OF SIMILAR WORKS SATISFYING QUALIFICATION CRITERION

COMPLETED DURING THE LAST 5 YEARS

S.

No.

Client's

Name and

Address

Name of the Work &

Location

Scope of work carried out by the

Bidder

Agreement

/ Letter of

Award No. and date

Contract Value

Awarded Actual on completion

Date of start Date of Completion Reasons for delay in completion if any

Ref. of document

(with page no.) in support of meeting

Qualification

Criterion

As per

LOA/

Agreement

Actual

SEAL AND SIGNATURE OF THE BIDDER

Note :

1.

2.

In support of having completed above works, attach self attested copies of the completion certificate from the owner/client or Executing Agency / Consultant appointed by owner /

Client indicating the name of work, the description of work done by the Bidder, date of start, date of completion (contractual & actual) and contract value as awarded and as executed by the Bidder . “Contract Value” shall mean gross value of the completed work including cost of materials supplied by the owner/client but excluding those supplied free of cost.

Credential certificates issued by Govt. Organizations / Semi Govt. Organizations of

Central or State Government; or by Public Sector Undertakings / Autonomous bodies of

Central/ State Government or their subsidiaries/ by Public Ltd. Company listed in

Stock Exchange in India or Abroad or subsidiaries of such companies shall only be accepted for assessing the eligibility of a Tenderer. Certificates issued by one of the aforesaid organizations as a lead member (having equity stack of 51% or more) of a Joint

Venture (JV) for a work executed for the JV, will also be acceptable. In case of PPP projects if the bidder has executed a work for a concessionaire or by the public authority concerned, will also be acceptable.

Page 28 of 145

5.

6.

7.

3.

4.

In case of a Certificate from a Public Limited Company the Bidder should also submit documentary proof that the Public Ltd. Company was listed in Stock Exchange in India or

Abroad when the work was executed for it.

Information must be furnished for works carried out by the Bidder in his own name or proportionate share as member of a Joint Venture. In the latter case details of contract value including extent of financial participation by partners in that work should be furnished.

If a Bidder has got a work executed through a Subcontractor on a back to back basis, the

Bidder cannot include such a work for his satisfying the Qualification Criterion even if the

Client has issued a Completion Certificate in favour of that Bidder.

Use a separate sheet for each partner in case of a Joint Venture.

Only similar works completed during the last 5 years prior to the last stipulated date for submission of Bid, which meet the Qualification Criterion need be included in this list.

Only those works mentioned in Annexure IX shall be given in this Performa.

Page 29 of 145

SOLVENCY CERTIFICATE FROM A NATIONALISED

OR A SCHEDULED ICAR/PMC

Proforma 2

This is to certify that to the best of our knowledge and information, M/s having their registered office at

,

, a customer of our Bank, is a reputed company with a good financial standing and can be treated as solvent to the extent of Rs. .

This certificate is issued without any guarantee or risk and responsibility on the Bank or any of its officers.

Signature with date

Senior Bank Manager (Name of Officer issuing the

Certificate)

Name, address & Seal of the Bank/ Branch

Note:

Banker‟s Certificate should be on letter head of the Bank.

Page 30 of 145

Proforma 3

DECLARATION BY THE BIDDER

(Affidavit on Non-Judicial Stamp Paper of Rs.10/- duly attested by Notary / Magistrate)

This is to certify that We, M/s. confirm that:-

, in submission of this offer i) We have visited the site of work and seen the working conditions, approach road / path, availability of water, electricity, construction labour, construction materials and other relevant requirements connected with the work.

ii) We have neither concealed any information/document which may result in our disqualification nor made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements; iii) During the past three years prior to the deadline for submission of bids, no contract awarded to us has been determined.

iv) No Central / State Government Department/ Public Sector Undertaking or Enterprise of

Central / State Government has banned/suspended business dealings with us as on date.

v) We have submitted all the supporting documents and furnished the relevant details as per prescribed format and we agree to submit, without delay additional information / documents which may be demanded by RITES Ltd.

vi) List of Similar Works satisfying Qualification Criterion indicated in Proforma 1 does not include any work which has been carried out by us through a Subcontractor on a back to back basis.

vii) The information and documents submitted with the Tender and those to be submitted subsequently by way of clarifications are correct and we are fully responsible for the correctness of the information and documents submitted by us.

viii) We have not failed to service the principal amount or interest or both of a loan account / credit limit from any Bank or Financial Institution during a period of one year prior to the deadline for submission of bids.

ix) *The original instruments of EMD and Cost of Tender Document, in physical form shall be deposited by us with RITES Ltd. within a week from the date of opening of Technical

Bid failing which RITES Ltd. may reject the bid and also take action to debar us from participating in Tenders invited by RITES Ltd. for a period of two years.

OR

*We are exempted from payment of cost of Tender Document and EMD and the certified copies of original documents in support of such exemption shall be deposited by us with

Page 31 of 145

x)

RITES Ltd. within a week from the date of opening of Technical Bids and original documents produced on demand, failing which RITES Ltd. may reject the bid and also take action to debar us from participating in Tenders invited by RITES Ltd. for a period of two years.

(* Delete whichever is not applicable)

We understand that in case any statement/information/document furnished by us or to be furnished by us in connection with this offer, is found to be misleading or false, our EMD in full will be forfeited and business dealings will be banned.

SEAL, SIGNATURE & NAME OF THE BIDDER

SIGNING THIS DOCUMENT

Page 32 of 145

ANNEXURE II

DRAFT MEMORANDUM OF UNDERSTANDING EXECUTED

BY MEMBERS OF THE CONSORTIUM / JOINT VENTURE

(On each firm‟s Letter Head)

- DELETED -

Page 33 of 145

ANNEXURE III

FORMAT FOR POWER OF ATTORNEY TO AUTHORISED SIGNATORY

POWER OF ATTORNEY

(To be executed on non-judicial stamp paper of the appropriate value in accordance with relevant

Stamp Act. The stamp paper to be in the name of the firm/ company who is issuing the Power of

Attorney).

We, M/s. (name of the firm/company with address of the registered office) hereby constitute, appoint and authorize Mr./Ms. employed with us and holding the position of

(Name and residential address) who is presently and whose signature is given below as our Attorney to do in our name and our behalf all or any of the acts, deeds or things necessary or incidental to our bid for the work “Supply, Installation, Integration, Testing & Commissioning

of Audio Visual And Conferencing System For Auditorium At NASC Complex, Pusa, New

Delhi” (name of work), including signing and submission of application / proposal, participating in

the meetings, responding to queries, submission of information / documents and generally to represent us in all the dealings with RITES or any other Government Agency or any person, in connection with the works until culmination of the process of bidding, till the Contract Agreement is entered into with RITES and thereafter till the expiry of the Contract Agreement.

We hereby agree to ratify all acts, deeds and things lawfully done by our said Attorney pursuant to this Power of Attorney and that all acts, deeds and things done by our aforesaid Attorney shall always be deemed to have been done by us.

(Add in the case of a Consortium/Joint Venture)

Our firm is a Member/Lead Member of the Consortium of

.

Dated this the day of 20

, and

(Signature and name of authorized signatory being given Power of Attorney)

(Signature and name in block letters of *All the partners of the firm, * Authorized Signatory for the Company)

(* Strike out whichever is not applicable)

Seal of firm/ Company

Witness 1:

Name:

Address:

Occupation:

Witness 2:

Name:

Address:

Occupation:

Page 34 of 145

Notes:

- In case the Firm / Company is a Member of a Consortium/ JV, the authorized signatory has to be the one employed by the Lead Member.

- The mode of execution of the Power of Attorney should be in accordance with the procedure, if any, laid down by the applicable law and the charter documents of the executants(s) and when it is so required the same should be under common seal affixed in accordance with the required procedure.

Page 35 of 145

ANNEXURE IV

FORMAT FOR POWER OF ATTORNEY TO LEAD MEMBER OF CONSORTIUM

/ JOINT VENTURE

-

DELETED -

Page 36 of 145

ANNEXURE V

FORM OF AGREEMENT

(ON NON JUDICIAL STAMP PAPER OF APPROPRIATE VALUE)

Agreement No. _ dated

THIS AGREEMENT is made on day of Two thousand between

RITES Ltd. a Government of India Enterprise and a Company registered under Companies Act,

1956 having its registered office at SCOPE Minar, Laxmi Nagar, Delhi - 110092 and its

Corporate Office at RITES BHAWAN, Plot No.1, Sector 29, Gurgaon (Haryana) representing through , RITES LIMITED acting for and on behalf of and as an Agent /Power of

Attorney Holder of “Indian Council of Agricultural Research, New Delhi hereinafter called the Employer (which expression shall, wherever the context so demands or requires, include their successors in office and assigns) on one part and M/s. hereinafter their successors and assigns) of the other part. called the

Contractor (which expression shall wherever the context so demands or requires, include his/

WHEREAS the Employer is desirous that certain works should be executed viz.

(brief description of the work) and has by Letter of Acceptance dated _ accepted a tender submitted by the Contractor for the execution, completion, remedying of any defects therein and maintenance of such works at a total Contract Price of Rs. (Rupees only)

NOW THIS AGREEMENT WITNESSETH as follows:-

1.

2.

In this Agreement words and expressions shall have the same meaning as are respectively assigned to them in the Conditions of Contract hereinafter referred to.

The following documents in conjunction with addenda/ corrigenda to Tender Documents shall be deemed to form and be read and construed as part of this agreement viz.

The Letter of Acceptance dated

Priced Schedule (Bill) of Quantities

.

Notice Inviting Tender and Instructions to Tenderers.

RITES Tender and Contract Form [DELETED]

Special Conditions

Schedules A to F.

Technical Specifications

Drawings

Amendments to Tender Documents (List enclosed)

General Conditions of Contract 2016 comprising of

(i) Conditions of Contract

(ii) Clauses of Contract

(iii) RITES Safety Code

(iv) RITES - Model Rules for the protection of Health and Sanitary arrangements for Workers

(v) RITES – Contractor's Labour Regulations.

Page 37 of 145

3.

4.

In consideration of the payment to be made by the Employer to the Contractor as hereinafter mentioned, the Contractor hereby covenants with the Employer to execute, complete, remedy defects therein and maintain the works in conformity in all respects with the provisions of the Contract.

The Employer hereby covenants to pay to the Contractor in consideration of the execution, completion, remedying of any defects therein and maintenance of the works, the contract price or such other sum as may become payable under the provisions of the contract at the time and in the manner prescribed by the Contract.

IN WITNESS whereof the parties hereto have caused their respective common seals to be hereinto affixed (or have herewith set their respective hands and seals) the day and year first above written.

SIGNED, SEALED AND DELIVERED BY

In the capacity of

On behalf of M/s.

(The Contractor)

In the presence of

Witnesses (Signature, Name &

Designation)

1.

2. representing RITES LIMITED

In the capacity of Agent / Power of

Attorney Holder

For and on behalf of

(The Employer)

In the presence of

Witnesses (Signature, Name &

Designation)

1.

2.

Page 38 of 145

ANNEXURE VI

INTEGRITY PACT

Between

RITES LTD. acting for and on behalf of and as an Agent / Power of Attorney Holder of

Indian

Council of Agricultural Research, New Delhi

hereinafter called the “Employer” and

M/s hereinafter referred to as "The Bidder/Contractor"

Preamble

The Employer intends to award, under laid down organizational procedures, contract/s for

Supply, Installation, Integration, Testing & Commissioning of Audio Visual And

Conferencing System For Auditorium At NASC Complex, Pusa, New Delhi”. The Employer

values full compliance with all relevant laws and regulations, and economic use of resources, and of fairness and transparency in his relations with the Bidder/s and/or contractor/s.

In order to achieve these goals, the Employer will appoint an Independent External Monitor

(IEM) who will monitor the Tender process and execution of the contract for compliance with the principles mentioned above.

Section 1 – Commitments of the Employer

(1) The Employer commits himself to take all measures necessary to prevent corruption and to observe the following principles:-

1.

2.

No employee of the Employer, personally or through family members, will in connection with the tender or for the execution of the contract, demand, take a promise for or accept, for self or third person, any material or immaterial benefit which the person is not legally entitled to.

The Employer will, during the tender process, treat all Bidders with equity and reason. The Employer will in particular, before and during the tender process, provide to all Bidders the same information and will not provide to any Bidder confidential/additional information through which the Bidder could obtain an advantage in relation to the tender process or the contract execution.

The Employer will exclude from the process all known prejudiced persons.

3.

(2) If the Employer obtains information on the conduct of any of his employees which is a criminal offence under the IPC (Indian Penal Code) /PC (Prevention of Corruption) Act, or if there be a substantive suspicion in this regard, the Employer will inform its Chief

Vigilance Officer and in addition can initiate disciplinary action.

Page 39 of 145

Section 2 – Commitments of the Bidder/Contractor

(1) The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution.

1.

2.

The Bidder/Contractor will not directly or through any other person or firm, offer, promise or give to any of the Employer‟s employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he is not legally entitled to, in order to obtain in exchange any advantage of any kind whatsoever during the tender process or during the execution of the contract.

The Bidder/Contractor will not enter with other Bidders into any undisclosed agreement or understanding, whether formal or informal. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or any other actions, to restrict competitiveness or to introduce cartelization in the bidding process.

3.

The Bidder/Contractor will not commit any offence under the relevant IPC/PC

Act; further the Bidder/ Contractor will not use improperly, for purposes of competition or personal gain, or pass on to others, any information or document provided by the Employer as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.

4.

The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, is committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract.

(2) The Bidder/ Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.

Section 3-Disqualification from tender process and exclusion from future contracts

If the Bidder/Contractor, before award or during execution has committed a transgression through a violation of Section 2 above, or in any other form such as to put his reliability or credibility in question, the Employer is entitled to disqualify the Bidder/Contractor from the tender process or take action as per the procedure mentioned in the "Guideline on banning of business dealing" annexed and marked as Annexure "A".

Section 4- Compensation for Damages

(1) If the Employer has disqualified in terms of the provisions in Section 3, the

Bidder/Contractor from the tender process prior to the award of contract, the Employer is entitled to demand and recover the damages equivalent to Earnest Money Deposit/ Bid

Security.

Page 40 of 145

(2) If the Employer has terminated the contract during execution in terms of the provisions under Section 3, the Employer shall be entitled to demand and recover from the

Contractor the damages equivalent to Earnest Money Deposit, Security Deposits already recovered and Performance Guarantee, which shall be absolutely at the disposal of the

Employer.

Section -5 Previous transgression

(1) The Bidder/ Contractor declares that no previous transgression occurred in the last 3 years with any other Company in any country conforming to the Anti-Corruption approach or with any other Public Sector Enterprise in India that could justify his exclusion from the tender process.

(2) If the Bidder/Contractor makes incorrect statement on this subject, he can be disqualified from the tender process or action can be taken as per the procedure mentioned in

"Guideline on banning of business dealing".

Section -6 Equal treatment of all Bidders/Contractors/Sub-Contractors

(1) The Bidder/Contractor undertakes to demand from all partners/sub-contractors (if permitted under the conditions/ clauses of the contract) a commitment to act in conformity with this Integrity Pact and to submit it to the Employer before signing the contract.

(2) The Bidder/ Contractor confirms that any violation by any of his partners/sub-contractors to act in conformity with the provisions of this Integrity Pact can be construed as a violation by the Bidder/Contractor himself, leading to possible Termination of Contract in terms of Section 4.

(3) The Employer will disqualify from the tender process all bidders who do not sign this Pact or violate its provisions.

Section 7- Criminal charges against violating Bidders/Contractors/Sub-Contractors

If the Employer obtains knowledge of conduct of a Bidder, Contractor or Partners/Sub-

Contractor, or of an employee or a representative or an associate of a Bidder, Contractor or

Sub- Contractor, which constitutes corruption, or if the Employer has substantive suspicion in this regard, the Employer will inform the same to its Chief Vigilance Officer.

Section -8 Independent External Monitor/Monitors

(1) The Employer shall appoint competent and credible Independent External Monitor for this

Pact. The task of the Monitor is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement.

(2) The Monitor is not subject to instructions by the representatives of the parties and will perform his functions neutrally and independently. He will report to the CMD/RITES

Ltd.

(3) The Bidder/Contractor accepts that the Monitor has the right of access without restriction to all Project documentation of the Employer including that provided by the Contractor.

The Contractor will also grant the Monitor, upon his request and demonstration of a valid

Page 41 of 145

interest, unrestricted and unconditional access to his project documentation. The same is applicable to Partners/Sub-Contractors. The Monitor is under contractual obligation to treat the information and documents of the Bidder/ Contractor/Partners/ Sub-

Contractor with confidentiality.

(4) The Employer will provide to the Monitor sufficient information about all meetings among the parties related to the Project provided such meetings could have an impact on the contractual relations between the Employer and the Contractor. The parties offer to the Monitor the option to participate in such meetings.

(5) As soon as the Monitor notices or has reason to believe that violation of the agreement by the Employer or the Bidder/ Contractor, has taken place, he will request the Party concerned to discontinue or take corrective action , or to take any other relevant action.

The Monitor can in this regard submit non-binding recommendations. Beyond this, the

Monitor has no right to demand from the parties that they act in a specific manner or refrain from action or tolerate action.

(6) The Monitor will submit a written report to the CMD/RITES Ltd. within 8-10 weeks from the date of reference or intimation to him by the Employer and should the occasion arise, submit proposal for correcting problematic situations.

(7) If the Monitor has reported to the C MD/RITES Ltd. of a substantiated suspicion of an offence under relevant IPC/PC Act, and the CMD/RITES Ltd. has not, within reasonable time, taken visible action to proceed against such offender or reported it to the Chief Vigilance Officer, the Monitor may also transmit this information directly to the Central Vigilance Commissioner.

(8) The word Monitor would include both singular and plural.

Section – 9 Pact Duration

This pact begins when both parties have legally signed it. It expires for the Contractor when his Security Deposit is released on completion of the Maintenance Period and for all other

Tenderers six months after the Contract has been awarded.

If any claim is made/lodged during this time the same shall be binding and continue to be valid despite the lapse of this pact specified above, unless it is discharged/determined by

CMD/RITES Ltd.

Section- 10 Other Provisions

(1) This agreement is subject to Indian Law. Place of performance and jurisdiction shall be as stated in the Contract Agreement.

(2) Changes and supplements as well as termination notices need to be made in writing.

Page 42 of 145

(3) If the Contractor is a partnership or a consortium, this agreement must be signed by the

Partner in charge/ Lead Member nominated as being in-charge and who holds the Power of Attorney signed by legally authorized signatories of all the partners/Members. The

Memorandum of Understanding /Joint Venture Agreement will incorporate a provision to the effect that all Members of the Consortium will comply with the provisions in the

Integrity Pact to be signed by the Lead Member on behalf of the Consortium. Any violation of Section 2 above by any of the Partners/Members will be construed as a violation by the consortium leading to possible Termination of Contract in terms of

Section 3

(4) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.

RITES Ltd.

Agent / Power of Attorney Holder

(For & on behalf of the Employer)

(Office Seal)

(For the Bidder/Contractor)

(Office Seal)

Place:…………………………

Date:……………………….

Witness 1:

(Name & Address) -----------------------------

-----------------------------

-----------------------------

-----------------------------

Witness 2

(Name & Address) -----------------------------

-----------------------------

-----------------------------

-----------------------------

Page 43 of 145

ANNEX-A

Guidelines on Banning of Business Dealings

1.

Introduction

1.1 RITES, being a Public Sector Enterprise and „State‟, within the meaning of Article 12 of

Constitution of India, has to ensure preservation of rights enshrined in Chapter III of the

Constitution. RITES has also to safeguard its commercial interests. It is not in the interest of

RITES to deal with Agencies who commit deception, fraud or other misconduct in the execution of contracts awarded / orders issued to them. In order to ensure compliance with the constitutional mandate, it is incumbent on RITES to observe principles of natural justice before banning the business dealings with any Agency.

1.2 Since banning of business dealings involves civil consequences for an Agency concerned, it is incumbent that adequate opportunity of hearing is provided and the explanation, if tendered, is considered before passing any order in this regard keeping in view the facts and circumstances of the case

.

2.

Scope

2.1 The procedure of (i) Suspension and (ii) Banning of Business Dealing with Agencies, has been laid down in these guidelines.

2.2 It is clarified that these guidelines do not deal with the decision of the Management not to entertain any particular Agency due to its poor / inadequate performance or for any other reason.

3.

2.3 The banning shall be with prospective effect, i.e., future business dealings.

Definitions

In these Guidelines, unless the context otherwise requires: i) ii) a) b)

`Bidder / Contractor / Supplier' in the context of these guidelines is indicated as

„Agency‟.

„Competent Authority‟ and „Appellate Authority‟ shall mean the following:

The Director shall be the „Competent Authority‟ for the purpose of these guidelines. CMD, RITES shall be the „Appellate Authority‟ in respect of such cases.

CMD, RITES shall have overall power to take suo-moto action on any information available or received by him and pass such order(s) as he may think appropriate, including modifying the order(s) passed by any authority under these guidelines.

Page 44 of 145

iii) „Investigating Department‟ shall mean any Department, Division or Unit investigating into the conduct of the Agency and shall include the Vigilance

Department, Central Bureau of Investigation, the State Police or any other department set up by the Central or State Government having powers to investigate.

iv) „Banning Committee‟ shall mean a Committee constituted for the purpose of these guidelines by the competent authority. The members of this Committee shall not, at any stage, be connected with the tendering process under reference.

4.

Initiation of Banning / Suspension

:

Action for banning / suspension business dealings with any Agency should be initiated by the department/ unit having business dealings with them after noticing the irregularities or misconduct on their part.

5.

Suspension of Business Dealings

5.1 If the conduct of any Agency dealing with RITES is under investigation by any department, the

Competent Authority may consider whether the allegations under investigation are of a serious nature and whether pending investigation, it would be advisable to continue business dealing with the Agency. If the Competent Authority, after consideration of the matter including the recommendation of the Investigating Department/Unit, if any, decides that it would not be in the interest to continue business dealings pending investigation, it may suspend business dealings with the Agency. The order to this effect may indicate a brief of the charges under investigation. The order of such suspension would operate for a period not more than six months and may be communicated to the Agency as also to the Investigating Department.

The Investigating Department/Unit may ensure that their investigation is completed and whole process of final order is over within such period.

5.2 As far as possible, the existing contract(s) with the Agency may be continued unless the

Competent Authority, having regard to the circumstances of the case, decides otherwise.

5.3 If the Agency concerned asks for detailed reasons of suspension, the Agency may be informed that its conduct is under investigation. It is not necessary to enter into correspondence or argument with the Agency at this stage.

5.4 It is not necessary to give any show-cause notice or personal hearing to the Agency before issuing the order of suspension. However, if investigations are not complete in six months time, the Competent Authority may extend the period of suspension by another three months, during which period the investigations must be completed .

Page 45 of 145

6.

Grounds on which Banning of Business Dealings can be initiated

6.1 If the security consideration, including questions of loyalty of the Agency to the State, so warrants;

6.2 If the Director / Owner of the Agency, proprietor or partner of the firm, is convicted by a Court of Law for offences involving moral turpitude in relation to its business dealings with the

Government or any other public sector enterprises or RITES, during the last five years;

6.3 If there is strong justification for believing that the Directors, Proprietors, Partners, owner of the

Agency have been guilty of malpractices such as bribery, corruption, fraud, substitution of tenders, interpolations, etc;

6.4 If the Agency employs a public servant dismissed / removed or employs a person convicted for an offence involving corruption or abetment of such offence;

6.5 If business dealings with the Agency have been banned by the Govt. or any other public sector enterprise;

6.6 If the Agency has resorted to Corrupt, fraudulent practices including misrepresentation of facts;

6.7 If the Agency uses intimidation / threatening or brings undue outside pressure on the Company

(RITES) or its official in acceptance / performances of the job under the contract;

6.8 If the Agency indulges in repeated and / or deliberate use of delay tactics in complying with contractual stipulations;

6.9 Based on the findings of the investigation report of CBI / Police against the Agency for malafide/unlawful acts or improper conduct on his part in matters relating to the Company

(RITES) or even otherwise;

6.10 Established litigant nature of the Agency to derive undue benefit;

6.11 Continued poor performance of the Agency in several contracts; (Note: The examples given above are only illustrative and not exhaustive. The Competent Authority may decide to ban business dealing for any good and sufficient reason).

7. Banning of Business Dealings

7.1 A decision to ban business dealings with any Agency shall apply throughout the Company.

7.2 If the Competent Authority is prima-facie of view that action for banning business dealings with the Agency is called for, a show-cause notice may be issued to the Agency as per paragraph 8.1 and an enquiry held accordingly.

.

8.

Show-cause Notice

8.1 In case where the Competent Authority decides that action against an Agency is called for, a show-cause notice has to be issued to the Agency. Statement containing the imputation of misconduct or mis-behaviour may be appended to the show-cause notice and the Agency should be asked to submit within 30 days a written statement in its defence. If no reply is received, the decision may be taken ex-parte.

Page 46 of 145

8.2 If the Agency requests for inspection of any relevant document in possession of RITES, necessary facility for inspection of documents may be provided.

8.3 On receipt of the reply of the Agency, or in case no reply is received within the prescribed time, the Competent Authority shall refer the case along with relevant details to the Banning

Committee, which shall examine the reply of the Agency and other facts and circumstances of the case and submit its final recommendation to the Competent Authority for banning or otherwise. A final decision for Company-wide banning shall be taken by the Competent

Authority. The Competent Authority may consider and pass an appropriate speaking order: For exonerating the Agency; or for banning the business dealing with the Agency.

9.

8.4 The decision should be communicated to the Agency concerned along with a reasoned order. If it decided to ban business dealings, the period for which the ban would be operative may be mentioned.

Appeal against the Decision of the Competent Authority

9.1 The Agency may file an appeal against the order of the Competent Authority banning business dealing, etc. The appeal shall lie to Appellate Authority. Such an appeal shall be preferred within one month from the date of receipt of the order banning business dealing, etc.

9.2 Appellate Authority would consider the appeal and pass appropriate order which shall be communicated to the Agency as well as the Competent Authority.

10.

Review of the Decision by the Competent Authority

Any petition / application filed by the Agency concerning the review of the banning order passed originally by Competent Authority under the existing guidelines either before or after filing of appeal before the Appellate Authority or after disposal of appeal by the Appellate

Authority, the review petition can be decided by the Competent Authority upon disclosure of new facts /circumstances or subsequent development necessitating such review.

.

11.

Circulation of the names of Agencies with whom Business Dealings have been banned.

11.1 Depending upon the gravity of misconduct established, the Competent Authority of RITES may circulate the names of Agency with whom business dealings have been banned, to the

Ministry of Railways and PSUs of Railways, for such action as they deem appropriate.

11.2 If Ministry of Railways or a Public Sector Undertaking of Railways request for more information about the Agency with whom business dealings have been banned a copy of the report of Inquiring Authority together with a copy of the order of the Competent Authority/

Appellate Authority may be supplied

12.

Restoration

12.1 The validity of the banning order shall be for a specific time & on expiry of the same, the banning order shall be considered as "withdrawn".

12.2 In case any agency applies for restoration of business prior to the expiry of the ban order, depending upon merits of each case, the Competent Authority which had passed the original banning orders may consider revocation of order of suspension of business/lifting the ban on business dealings at an appropriate time. Copies of the restoration orders shall be sent to all those offices where copies of Ban Orders had been sent

Page 47 of 145

ANNEXURE VII

MANDATE FORM

To

RITES Ltd.

Dear Sir,

Authorization for payments through Electronic Fund Transfer System (RTGS/NEFT)

We hereby authorize RITES Ltd. to make all our payments, including refund of Earnest Money, through Electronic Fund

Transfer System (RTGS/NEFT). The details for facilitating the payments are given below:

1 NAME OF THE BENEFICIARY

(TO BE FILLED IN CAPITAL LETTERS)

2 ADDRESS WITH PIN CODE

3 (A) TELEPHONE NO. WITH STD CODE

(B) MOBILE NO.

4

A

B

BANK

BANK

PARTICULARS

NAME

TELEPHONE NO. WITH STD CODE

C BRANCH ADDRESS WITH PIN CODE

D

BANK

BANK

FAX NO. WITH STD CODE

E 11 CHARACTER IFSC CODE OF THE

BANK

(EITHER

ENCLOSE A CANCELLED CHEQUE OR OBTAIN

F

G

BANK

CERTIFICATE AS APPENDED)

BANK

ACCOUNT NUMBER AS APPEARING IN THE

CHEQUE BOOK

BANK

ACCOUNT TYPE (TICK ONE) SAVING

CREDIT

CURRENT

OTHERS

LOAN CASH

H IF OTHERS, SPECIFY

5 PERMANENT ACCOUNT NUMBER (PAN)

6 E-MAIL ADDRESS

I / We hereby declare that the particulars given above are correct and complete. If the transaction is delayed or credit it not effected at all for reasons of incomplete or incorrect information, I / We would not hold RITES Ltd. responsible. Bank charges for such transfer will be borne by us.

Date: SIGNATURE

(AUTHORISED SIGNATORY)

Name

BANK CERTIFICATION

It is certified that the above mentioned beneficiary holds Bank account No.

Bank particulars above are correct.

Date: with our branch and the

SIGNATURE

(AUTHORISED SIGNATORY)

Name______________________

OFFICIAL STAMP

Page 48 of 145

Form of Earnest Money Deposit

Bank

Guarantee Bond

„BLANK‟

ANNEXURE VIII

Page 49 of 145

ANNEXURE IX

Pre-Qualification Performa

Name of Work

Tender No.

Name of the Bidder:

Details of Cost of Tender

Document Paid by

Banker‟s Cheque / Pay

Order / Demand Draft

Details of EMD paid by

(i) Banker‟s Cheque/ Pay

Order/ Demand Draft

(ii) Bank Guarantee

Name & Address

of Issuing Bank

Amount Date of Issue Instrument

placed at

1

2

3

Annual Financial Turnover

S.No.

1

2

3

Financial Years Turn Over

201

5-16

201

4-15

201

3-14

(Rs In Lacs)

Profitability

S.No.

Documents

Placed at:

Financial Years Profit with (+)

sign or Loss with

(-) sign

(In Lacs)

201

5-16

Documents

Placed at:

201

4-15

201

3-14

Remarks

Remarks

Page 50 of 145

2

3

4

Similar Work Experience

S. No. Name

of work

Name

of

Client

1

Actual

Date of

Start

Actual

Date of

Completion

Actual

Completion

Cost

Completion

Certificates

Placed at :

Remarks

Net Worth

S.No.

1

Financial Years Net worth in Rs. Documents

Placed at:

201

5-16

Remarks

Solvency Certificate

Sl No. Name &

Address of

Issuing Bank

Solvency

Amount in

Rs.

Date of

Issuance

1.

Document

Placed at:

Remarks

Other documents to be submitted along with Tender documents:

Sl No.

1

2

3

Particulars

Declaration

Proforma-3 by the bidder as per

Self Attested Copy of Partnership Deed/

Memorandum and Articles of Association of the firm.

Written Power of Attorney of the signatory of the Tender on behalf of the tenderer. (Annexure-III)

Document

Placed at:

Remarks

Page 51 of 145

5

6

7

8

9

4 Self attested copy of a certificate, confirming that the applicant is working contractor or has executed any work within the last five years reckoned from the date of opening of tender, issued by

Railways, CPWD, MES, DOT, RITES,

State PWD or any other Central / State

Government Undertaking, Municipal

Body of Central / State Government or

Public Limited Company listed in Stock

Exchange in India & Abroad.

List of similar works satisfying qualification criterion completed during the last 5 years as per Proforma-1

Integrity Pact as per Annexure-VI

Self attested copy of

Corrigendum/Minutes of Pre-Bid

Meeting, if any.

RTGS/NEFT details as per Annexure- VII

Details of Construction Experience in key activities / specified components

NOT APPLICABLE

Page 52 of 145

List of 60 districts covered under IAP

Andhra Pradesh

Andhra Pradesh

Bihar

Bihar

Bihar

Bihar

Bihar

Bihar

Bihar

Chhatisgarh

Chhatisgarh

Chhatisgarh

Chhatisgarh

Chhatisgarh

Chhatisgarh

Chhatisgarh

Chhatisgarh

Chhatisgarh

Chhatisgarh

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Jharkhand

Madhya Pradesh

27

28

29

30

23

24

25

26

31

32

33

34

19

20

21

22

15

16

17

18

11

12

13

14

7

8

9

10

3

4

5

6

S.No

.

1

2

State District

Adilabad

Khammam

Arwal

Aurangabad

Gaya

Jamui

Jehanabad

Nawada

Rohtas

Bastar

Bijapur

Dantewada

Jashpur

Kanker

Kawardha

Koriya

Narayanpur

Rajnandgaon

Surguja

Bokaro

Chatra

Garhwa

Gumla

Hazaribagh

Kodarma

Latehar

Lohardaga

Pachim Singhbhum

Palamu

Purbi Singhbhum

Ram Garh

Saraikela

Simdega

Anuppur

Page 53 of 145

ANNEXURE X

47

48

49

50

43

44

45

46

39

40

41

42

35

36

37

38

55

56

57

58

51

52

53

54

59

60

Madhya Pradesh

Madhya Pradesh

Madhya Pradesh

Madhya Pradesh

Madhya Pradesh

Madhya Pradesh

Madhya Pradesh

Maharashtra

Maharashtra

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Orissa

Uttar Pradesh

West Bengal

Balaghat

Dindori

Mandla

Seoni

Shahdol

Sidhi

Umaria

Gadchiroli

Gondiya

Balangir

Debagarh / Deogarh

Gajapati

Kalahandi

Kandhamal / Phulbani

Kendujhar / Keonjhar

Koraput

Malkangiri

Mayurbhanj

Nabarangapur

Nuapada

Rayagada

Sambalpur

Sonapur

Sundargarh

Sonbhadra

Paschim Medinipur

Page 54 of 145

SECTION 2

TENDER AND CONTRACT FORM FOR

WORKS

DELETED

Page 55 of 145

SECTION 3

SPECIAL CONDITIONS

Page 56 of 145

SECTION - 3

SPECIAL CONDITIONS

1) All the statutory taxes i.e., GST, custom duty, VAT, Octroi, if any, paid to the government will be reimbursed as per actual on the submission of original proof of payment to RITES.

2) The successful bidder will ensure training for the Client of the complete installation system and educate them for independent running of the complete system for one year after testing & commissioning of the system.

3) The complete system will be operated and maintained for a further period of two years after successful completion of the Defect Liability period of one year in which the complete system will be operated and maintained by the bidder. The bidder will deploy adequate manpower as mentioned below for the successful operation of all the facility running simultaneously and to the complete satisfaction of the Client/PMC. The minimum requirement of manpower will be as under

a)

Supervisor- 1 No.

b)

Assistant – 4 Nos.

To undertake the maintenance for a further period of two years after successful completion of the Defect Liability period of one year, the bidder will obtain comprehensive insurance policy/warranty for a period of two years after the completion of DLP period for complete replacement of the equipment at full value in case of defect/fault arising during the maintenance period. Nothing extra will be paid on this account.

4) The deployment of adequate man-power to run the complete facility will be the responsibility of the

Bidder and failure to do so would result in recover as per the rates mentioned below:

-

Principal Supervisor @ Rs.2000/- per day of non-deployment

-

Other support supervisor/staff @ Rs.1500/- per day of non-deployment

5) An amount equivalent to 2% of the Final Built-up cost of the work will remain with Client/ withheld and shall be released after successful completion of the “Operation and

Maintenance” period of 2 (TWO) years as mentioned at Clause (3) above.

6) Bidders should submit a letter from Manufacturer in favour of ICAR, New Delhi/General

Manager/CP, RITES Limited, 3 rd

Floor, ROC-II, Plot No.-144, Sector-44, Gurgaon, undertaking manufacturer‟s warranty & 5(five) years service & spares support after the completion of warranty period, clearly mentioning the tender name & item/model details etc.

7) All the equipment provided under this contract shall be complete with power cables. The Equipment shall operate on 230 volts, 50 Hz single phase AC power supply and the power cables shall be fitted with 3 pin, 5A (OR) 15A plug tops complying with Indian Electrical standards.

Page 57 of 145

8) The equipments are to be supplied under this contract shall be the industry proven products and not the R&D models. The equipment shall confirm to the requirements of relevant Indian &

International Standards.

9) All the core components of the main system shall be from the same Original Equipment

Manufacturer (OEM) and other components, if any, shall be certified and approved from the main

OEM. Assembled product of different makes or refurbished products shall not be accepted.

10) The System Integrator (SI, also referred as Bidder in this document) should ensure that products / technologies /services quoted under this project are not declared end of life by the respective OEM and also ensure that End-of-Life of the proposed product is not earlier than TWO year from the date of successful taking over of the complete project.

11) The SI should ensure that the spares and upgrades for the product shall be available at least for

FIVE years from the date of successful taking over of the complete project.

12) During warranty period replacement of defective components or sub-components shall be replaced by the brand new spare parts bearing the same OEM part number. Only under exceptional circumstances of non-availability of spare of the same part number the compatible spare having different OEM part number may be accepted. However, in such cases the spare part to be supplied against the defective part shall be brand new and shall bear part number from the OEM.

13) The BOQ Item detail is not exhaustive. Any additional items / components as required for the successful completion of the work under taken may be assessed by the party and the same may be incorporated in the offer. Even at the time of execution, if any additional items / components are required to complete the system, notwithstanding the detail in BOQ as above, the same shall be provided free of cost by the bidder/SI (System Integrator).

14) The bidders should quote their prices for the complete scope envisaged for successful implementation of the system in all respect.

Page 58 of 145

SECTION 4

SCHEDULES A TO F

Page 59 of 145

SECTION 4

PROFORMA OF SCHEDULES

SCHEDULE „A‟

Schedule of quantities (As per Bill of Quantities attached)

(BOQ to be attached with Financial Bid)

SCHEDULE „B‟ –

Schedule of materials to be issued to the contractor. (Refer Clause 10 of Clauses of Contract)

S.No Description of items

1 2

Quantity Rates in Figures & words at which the material will

3 be charged to the contractor

4

Place of Issue

5

- Not Applicable -

SCHEDULE „C‟

Tools and plants to be hired to the contractor. (Refer clause 34 of Clauses of Contract).

S.No Description

1 2

Hire charges per day

3

- Not Applicable -

SCHEDULE „D‟

Extra schedule for specific requirements/documents for the work, if any.

- Not Applicable -

Place of Issue

4

Page 60 of 145

SCHEDULE „E‟ –

Schedule of components of Cement, Steel, other materials, POL,

Labour etc .for price escalation. (Refer Clause 10CC of Clauses of

Contract).

(To be worked out and filled by NIT approving authority. The

Components and their percentages may be modified depending on the nature of work)

CLAUSE 10 CC

Component of Cement (Xc) expressed as percent of total value of work 15 %

Component of steel (X5) expressed as percent of total value of work 20% Component of other materials (XM) (except cement & steel) expressed as per cent of total value of work 40% Component of labour (Y) expressed as percent of total value of work 25%

Component of P.O.L (Z) expressed as percent of total value of work - NIL

Total 100 %_

Page 61 of 145

SCHEDULE „F‟

Reference to General Conditions of Contract

Name of Work: Supply, Installation, Integration, Testing & Commissioning of Audio

Visual And Conferencing System For Auditorium At NASC Complex,

Pusa, New Delhi

Estimated cost of work:

Earnest money:

Performance Guarantee (Ref. Clause 1)

Security Deposit: (Refer clause 1A)

Notice Inviting Tender and Instruction to Tenderers

Rs. 10.69 Crores

Rs. 10.69 lacs (Rs. Ten lacs and Sixty

Nine Thousand Only)

5% of Tendered value

5% of Tendered value

Officer inviting tender:

GM/CP/RITES

CONDITIONS OF CONTRACT

Definitions

2 (iv) Employer

2(v) Engineer-in-Charge

2(vii) Accepting Authority

2(ix) Percentage on cost of materials and labour to cover all overheads and profits.

Indian Council of Agricultural Research, New Delhi

GM/CP/RITES

GM/CP/RITES

15%

2(x) Standard Schedule of Rates CPWD DSR 2016 and CPWD SOR 2016 (for

Electrical items)

2(xiii) Date of commencement of work

15 days from the date of issue of LOA or the first

date of handing over of site whichever is later

9 (a) (ii) General Conditions of Contract RITES General Conditions of Contract

2016 Edition

CLAUSES OF CONTRACT

Clause 1

1 (i) Time allowed for submission of

P.G. from the date of issue of

Letter of Acceptance subject

15 days.

Page 62 of 145

to maximum of 15 days

Maximum allowable extension beyond the period provided in

(i) above subject to a maximum of

Clause 2

Authority for fixing compensation under

Clause 2

Clause 2A

Whether Clause 2A shall be applicable

Clause 5

5.1 (a) Time allowed for execution of work

7 days

GM/CP/RITES

NO

Date of start

5 (Five) months from the date of start

15 days from the date of issue

of Letter of Acceptance or the first date of handing over of site whichever is later

4

5.1 (b) TABLE OF MILESTONE(S)

S.No Description of Milestone

2

(Physical)

1 1/8

3/8

3 3/4 th th th

( of the whole work )

( of the whole work )

( of the whole work )

Full.

Time allowed in days

(from date of start)

1/4 th

of completion period i.e. 30 Days

1/2 of completion period i.e. 60 Days.

Amount to be withheld in case of non achievement of milestone

1% of the tendered value of work.

1% of the tendered value of work.

3/4 th

of completion period

90 Days.

Full

1% of the tendered value of work.

As per Clause 2 of GCC

Page 63 of 145

Clause 5A shifting of stipulated date of completion

Competent Authority

Clause 6 A Whether Clause 6 or 6A applicable

Clause 7

Gross work to be done together with net payment/adjustment of advances for material collected, if any, since the last such payment for being eligible to interim payment

GM/CP/RITES

6A Applicable

Rs. 45.0 Lacs

Clause 10A i) Whether Material Testing Laboratory is to be provided at site.

ii) If “YES” list of equipments to be provided

Clause 10 B

Whether Clause 10 B(ii) to (v) applicable

Clause 10 CC

Whether Clause 10CC applicable

Clause 11

Specifications to be followed for execution of work

.

NO

Refer Annexure B-I of GCC/RITES

YES Clause 10 B (ii) & (iv) & (v)- Applicable

Clause- 10 B (iii) –Not Applicable

NO

For CPWD DSR Items:-

CIVIL WORKS

CPWD Specifications 2009 Vol. I & II with latest amendments

ELECTRICAL WORKS

CPWD General Specifications

Part I :Internal 2013

Part II :External 2013

Part III :Lifts & Escalators 2013

Part IV :Sub-stations 2013

Part V :Wet Riser Sprinkler System 2006

Part VI :Heating, Ventilation &

Air Conditioning Works 2004

Part VII:DG Sets 2013

For Non DSR Items and items of

Specialised nature in Railway Works etc.

Technical Specifications under Section No.

5.

Page 64 of 145

Clause12

Clause 12.2 Deviation Limit beyond which

12.3 & 12.5 Clauses 12.2,12.3 & 12.5shall apply i) For Non-foundation items.

Plus 25%

Minus No limit ii) For Foundation Items

Plus 100%

Minus No limit

Note: i) For Earthwork, individual classi- fication quantity can vary to any extent but overall Deviation Limits will be as above.

Clause 12.5 Definition of Foundation item if other than that described in

Clause 12.5

Clause 16 Competent Authority for deciding reduced rates

Clause 17 Maintenance Period

Clause 18 List of machinery, tools

& plants to be deployed by the Contractor at site

(Commensurate with approved schedule) :- work

NOT APPLICABLE

GM/CP/RITES

12 months

As per requirement of work & duly approved by engineer-in-Charge to complete the work within given time schedule.

Page 65 of 145

Clause 25

25 (i) Appellate Authority

Appointing Authority

Whether Clause 31A or 32 is applicable

Clause 36 (i)

& (iii)

-

-

GGM/CP (SBU Head)/RITES

Divisional Head/RITES

32 is applicable

Minimum Qualifications & Experience required and Discipline to which should belong

Designation

Principal Technical

Representative

Engineers

Minimum

Qualification

Graduate Engineer

Graduate Engineer

Minimum working experience

5

2

Discipline to which should belong

E & C Engg.

E & C Engg.

Number

1

2

36 (iv) Recovery for non-deployment of Principal Technical Representative and Deputy Technical Representative

Designation

Principal Technical Representative

Engineer (Degree Holder)

Rate of Recovery per month (in Rs.) for non- deployment

45,000/-

25,000/-

Clause 42 i)(a) Schedule/statement for determining theoretical quantity of cement & bitumen on the basis of Delhi

Schedule of Rates printed by CPWD ii) a) b) c) d)

Variations permissible on theoretical

Quantities

Cement

- for works with estimated cost put to tender not more than Rs.5 lakhs

- for works with estimated cost put to plus/minus tender more than Rs.5 lakhs

Bitumen for All Works

Steel Reinforcement and structural steel sections for each diameter, section and category

All other materials

DSR 2016

3% plus / minus

2%

2.5% plus only & nil on minus side

2% plus / minus

Nil

Page 66 of 145

RECOVERY RATES FOR QUANTITIES BEYOND PERMISSIBLE

VARIATION

Sl.

No.

Description of

Item

Rates in figures and words at which recovery shall be made from the Contractor

Excess beyond permissible variation

Less use beyond the permissible variation

1 Cement reinforcement

3 Structural Sections

NOT APPLICABLE

5 free

Bitumen issued at stipulated fixed price

Clause 46

Details of temporary office accommodation including number of rooms and their sizes as well as furniture to be made available by the Contractor

Whether Clause 46.11.1A applicable

---------NOT APPLICABLE--------

(If not applicable indicate accordingly)

NO

NO Whether Clause 46.13A applicable

Clause 46.17

City of Jurisdiction of Court

Clause 47.2.1

Sum for which Third Party

Insurance to be obtained.

Clause 55

Whether clause 55 shall be applicable.

If yes, time allowed for completion of sample floor/unit.

Delhi

Rs. 10 Lakhs per occurrence with the number of occurrences limited to four.

Not applicable

NO

Page 67 of 145

SECTION 5

TECHNICAL SPECIFICATIONS

Page 68 of 145

SECTION 5

TECHNICAL SPECIFICATIONS

Supply and installation of all the hardware and software items as per the scope of work and detailed technical specifications. All these equipment/ accessories will be warranted and must operate at/OR above the guaranteed values with regard to availability.

The system spare parts, as and when required and complete maintenance support of the system in future shall be back to back guaranteed from OEM for a period of 05 (Five)

Years from the date of successful taking over of the complete project by the owner from the SI.

One copy of Hardware and Software documentation shall be provided along with the supply of equipment. The vendor shall provide services as detailed in this specification.

The vendor shall arrange for all tools, tackles, testing instruments etc., as required during all operations such as transportations, installation, testing and commissioning etc., for completing the scope of work as per this specification. These tools and tackles and testing instruments etc., shall be allowed to be taken back by the vendor. The vendor shall undertake all testing and commissioning activities and shall provide assistance during inspection and acceptance testing by the owner.

Vendor shall provide all required equipment and services, whether explicitly mentioned in these specifications or not, to fulfil the intent of the specification and to ensure completeness, operability and maintainability of the system at no extra cost to the owner.

Vendor shall furnish the part Number/ Product identification Number for all products as provided by the original manufacturer.

Vendor shall provide a clear and explicit activity wise action plan and schedule of completion of the above work.

Vendor shall provide a detailed list of Project Manager, Site Engineer, and Technician etc., who are intended to be assigned for commissioning of the subject project, clearly mentioning the detail of their work experience, certifications and other skills. This shall be subject to approval by Engineer In-charge.

Vendor shall ensure that the manpower is technically competent and must possess requisite certifications from various OEMs as required. RITES shall have discretion of accepting or rejecting the manpower proposed.

Page 69 of 145

During the execution phase, any changes in the manpower deployment at site should be notified in writing to the Engineer In-Charge with the details of the new person assigned for the task, and approval for the same to be sought.

Information to be provided by the bidder:

The Bidder furnishes complete information asked in this specification. Bidder has to quote for the total scope of supply and other works. Amongst other things, the Bidder may supply the details / specifications regarding the following items along with his bid for complete understanding of the work.

Hardware: Comprehensive write-up on features of H/W Systems under AV Package.

Software: Comprehensive write-up on features of software including but not limited to control panel software, Video Production Software, Class room management Software,

Video encoding Software.

Site Preparation, Supervision and Installation.

Special requirements, if any, of operating parameters like the range of temperature, humidity, dust level and power requirement.

Printed Brochures / Pamphlet / Leaflet illustrating Technical details / specifications etc. for all the items / materials quoted should be provided.

The Bidder must address all the above aspects and the bid shall be deemed to be in line with the technical and other particulars mentioned in the tender specifications.

Site Preparation, Supervision and Installation:

It shall be the responsibility of the vendor to supervise the site preparation by the owner to ensure that the site is prepared as per his requirements such as environmental conditions, power requirements etc. The vendor shall ensure that his system operates efficiently under these conditions.

The vendor shall furnish along with his offer a list of facilities and other necessities required by him, if any, for site preparation etc. The vendor shall be fully responsible for installation and commissioning of the equipment including cabling related to installed equipment (except power cables) and other related activities such as unpacking, uncarting, inspection etc. for which the owner shall provide the required space at his premises, the vendor will have to arrange by himself all testing equipment and tools required for installation/maintenance and make his own transport arrangements.

Page 70 of 145

The vendor shall furnish schematic drawings, signal flow diagrams with cable details, color coding and numbering of the cables.

Final version of the Schematic drawings after execution shall be submitted as “As Built”

Drawings and duly approved by Engineer-In-Charge / consultant.

Detailed shop drawings for all the equipment to be flushed on the table / lectern / related furniture to be provided before starting the execution to the Engineer-In-charge / consultant, since it carries dependency on the other vendors on the site.

Testing & Acceptance by Client/RITES:

All the items supplied under this contract shall be verified by RITES to confirm that all the hardware supplied matches to the specifications, and all the equipment are in good, working condition and are free from any physical defects / damages, till the time of site handover.

Any other test(s), as Client/RITES may deem fit, so as to confirm the performance or to establish the technical specifications of either individual hardware item or for the integrated operation of network, shall be done by Supplier at the Site. Should the results of these tests show any deficiency from the corresponding specifications or operation is not up to the desired level of performance, Supplier shall do the necessary replacement so as to make the Hardware items to function at the desired level of performance. All costs for such replacements shall be borne by Supplier.

After satisfactory completion of acceptance tests and installation of the equipment / systems / software by the Vendor, the acceptance certificate will be issued by the RITES in writing after which the Equipment shall be handed over to Client.

Acceptance or waiver of tests will not relieve the Vendor from the responsibility to furnish material in accordance with the specifications.

RITES also reserves the right to conduct any testing / benchmarking of previously approved materials at any stage before taking over of the system and if the same reveal non-compliance to the specifications, the Vendor shall take necessary action so that the material / system / software conforms to the specifications to the satisfaction of the

Engineer-In-Charge.

Page 71 of 145

Warranty:

Vendor shall provide on-site comprehensive back to back warranty from OEM for trouble free operation of hardware, software and Licenses (if any), supplied under this contract, for a minimum period of THREE (03) years after commissioning and successful testing and taking over of the project. Documentary proof from OEM confirming 03 (three) years On-site comprehensive warranty of and/or comprehensive

Insurance cover for 2 years after completion of DLP should be submitted at the time of handing over/completion of DLP. During this period, it will be the responsibility of the vendor to maintain and support the hardware and software fully and ensure availability of the same.

The detailed scope of services to be provided by vendor during Warranty period, shall include but not limited to the following:

Vendor shall provide comprehensive maintenance support for satisfactory performance of all Hardware supplied under this contract, Projectors including support for Lamps for

03(three) Year of Operation.

In case of any failure/non-operation of above items the same shall be attended by the vendor within 24 hours of lodging the complaint by Client, excluding intervening holidays. A call report sheet giving the details of problem attended, duly signed by the concerned end user shall be maintained.

The vendor shall arrange for standby equipment, if the faulty equipment is not rectified within FIVE (05) working days or items are taken out of Client premises for servicing/repair. Mechanical breakages and any consumables are not covered in the warranty.

Vendor should also provide details of appropriate Escalation Matrix in case of nonsatisfactory service support.

The Vendor shall be responsible for providing, free of cost, all supplies, spares and services (including labour) necessary for maintenance during warranty.

Site Visit:

The bidders are strongly advised to visit and examine the site and to obtain himself, on his own responsibility, all information, such as the architectural and interior drawings, that may be necessary for preparing the Bid and entering into a Contract. The expenditures of visiting the sites shall be at bidders own expenses.

Page 72 of 145

The bidders should do necessary environmental survey for cabling, containments

(conduiting and raceways) and towards RF implementation (using specific analysers meant for wireless microphone system installation across the facility).

Scope for Installation, Testing, Commissioning and Handing over of the Project

“The BOQ estimated by Client/Consultant is not exhaustive. Any additional items / components as required for the successful completion of the work under taken may be assessed by the bidder and the same may be incorporated in the offer. Even at the time of execution, if any additional items / components are required to complete the system, notwithstanding the detail in BOQ as above, the same shall be provided free of cost by the bidder”.

 The scope of work comprises Installation, Testing, Commissioning and Handing over of the supplied equipment under this project. The bidder shall provide a comprehensive integrated turnkey solution. Any minor Electrical works, civil interior work for false ceiling, and flooring and minor carpentry work relating to the installation of the equipment supplied under this project shall be in the scope of the bidder/SI. The bidders shall quote for a total integrated turnkey solution covering all the above.

 The bidder shall supply and install all required connectors, cables, etc. as well as the programming necessary to complete the installation of the project.

 Installation & Commissioning inter alia including Supply, laying with suitable protection, termination / fixing of cables, connectors, lugs and other items, not specifically even mentioned in the Technical Specification, BOQ and is required to successfully complete the project shall be provided free of cost by the bidder.

Page 73 of 145

TERMS & CONDITIONS (FOR OPERATION AND MAINTENANCE SUPPORT):

1. During the term of the contract and operation and maintenance period, the BIDDER will maintain the equipment in perfect order and working condition and for this purpose will provide the following repairs and maintenance services: a) Professionally qualified personnel in adequate numbers who have expertise in the hardware and system software installed will provide these services. b) The Bidder shall rectify any defects, faults and failures in the equipment and shall repair / replace worn out or defective parts (including plastic parts and lens)of the equipment during working hours i.e. from 8.00 A.M. to 8.00 P.M. on all working days (viz. Monday to Saturday). In case any defects, faults and failures in the equipment could not be repaired or rectified during the said period, the Bidder personnel are required to accomplish their duties beyond the said schedules in case of any situation if it warrants. In cases where unserviceable parts of the equipment need replacement, the Bidder shall replace such parts, at no extra cost to the ICAR/PMC, with brand new parts or those equivalent to new parts in performance. For this purpose the Bidder shall keep sufficient stock of spares at the premises of The Bidder. c) The maximum response time for a maintenance complaint from the site of installation (i.e. time required for Bidder‟s maintenance engineers to report to the installations after a request portal / call / fax /e-mail is made or letter is written) shall not exceed 2 hours. d) The BIDDER shall ensure that faults and failures intimated by ICAR/PMC as above are set right within 4 (four) hours of being informed of the same. In any case of replacement of parts, the equipment should be made workable and available not later than 24 hours. e) However replacement with new equipment shall be carried out within 7 days from date of intimation of fault / failure. f) In the event of the equipment not being repaired or a workable solution not provided during AMC period, a penalty, per working day or part thereof for the delay, will be charged at the rate mentioned below, subject to maximum amount of ten (10) per cent of the total consideration. The bidder may provide temporary equivalent replacement as a workable solution to avoid the penalty.

 For VC end-point – Rs.1,000/- per day

Page 74 of 145

 For control processor – Rs 1,500/- per day

 For displays – Rs 2,000/- per day

 For matrix switcher/router – Rs 2,000/- per day

 For audio DSP – Rs 1,000/- per day g) The BIDDER shall ensure that the meantime between failures (MTBF) (including any malfunctioning, breakdown or fault) in the equipment or any part thereof as calculated during any and every quarter (period of three consecutive months) is not less than 90 days. h) Preventive maintenance: the BIDDER shall conduct Preventive Maintenance (including but not limited to inspection, testing, satisfactory execution of all diagnostics, cleaning and removal of dust and dirt from the interior and exterior of the equipment, and necessary repair of the equipment) once within first 15days of the award of contract and once within the first 15 days of every alternate month during the currency of this agreement and the operation and maintenance period on a day and time to be mutually agreed upon. Notwithstanding the foregoing the BIDDER recognizes

ICAR/PMC‟s operational needs and agrees that ICAR/PMC shall have the right to require the

BIDDER to adjourn preventive maintenance from any scheduled time to a date and time not later than 15 working days thereafter. i) Qualified maintenance personnel totally familiar with the equipment shall perform all repairs and maintenance service to be provided in terms of the contract. j) The Bidder shall maintain a register at its site in which, the bidder‟s operator /supervisor shall record each event of failure and / of malfunction of the equipment. The bidder personnel engineer shall enter the details of the action taken in such register. Additionally every time a preventive or corrective maintenance is carried out, the bidder personnel shall make, effect in duplicate, a field call report which shall be signed by him and thereafter countersigned by the ICAR/PMC‟s official. The original of the field call report shall be handed over to the ICAR/PMC‟s official. k) The bidder shall provide replacement equipment if any equipment is out of the premises for repairs.

2. The Bidder warrants that any new products supplied under the Contract are new, unused, of the most recent or current model. The Bidder further warrants that all the Products supplied under this

Page 75 of 145

Contract shall have no defect, arising from design or from any act of omission of the Bidder that may develop under normal use of the supplied products in the conditions prevailing in India.

3. Subsequent to the order being placed by the ICAR/PMC, in the event of bidder or the concerned

OEM being taken/ brought over by another company, all the obligations and execution of responsibilities under the agreement with ICAR/PMC should be passed on for compliance by the new company in the negotiation for their transfer.

4. Any worn or defective parts withdrawn from the equipment and replaced by the BIDDER shall become the property of the BIDDER and the parts replacing the withdrawn parts shall become the property of ICAR/PMC.

5. The BIDDER‟s maintenance personnel shall be given access to the equipment when necessary, for purpose of performing the repair and maintenance services indicated in this agreement.

6. ICAR/PMC shall arrange to maintain appropriate environmental conditions, such as those relating to space, temperature, power supply, dust within the acceptable limits required for equipment similar to that covered by this Agreement.

7. NO term or provision hereof shall be deemed waived and no breach excused, unless such waiver or consent shall be in writing and signed by the party claimed to have waived or consented. Any consent by any party to or waiver of a breach by other, whether express or implied, shall not constitute a consent to or waiver of or excuse for another different or subsequent breach.

8. If, in any month, the BIDDER does not fulfill the provisions of clauses 1(b), (c),(d), (e) and(h) only the proportionate maintenance charges for that period during the month will be considered payable by ICAR/PMC without prejudice to the right of the ICAR/PMC to terminate the contract. In such event the BIDDER was credited without deducting the proportionate maintenance charges for that month, the ICAR/PMC can deduct the same from future payments payable or the BIDDER shall refund the amount forthwith to ICAR/PMC on demand by ICAR/PMC.

9. On account of any negligence, commission or omission by the bidder personnel, and if any loss or damage caused to the Equipment, the BIDDER shall indemnify/pay/reimburse the loss suffered by the ICAR/PMC.

Page 76 of 145

10. Future additions of Hardware / Software:

10.1 The ICAR/PMC would have the right to: a) Disconnect / connect / substitute equipment or devices or any equipment /software acquired from another bidder. b) Expand the capacity / enhance the features / upgrade the hardware / software supplied, either from the bidder, or another bidder, or developed in-house, provided such changes or attachments do not prevent proper maintenance, from being performed or unreasonably increase the BIDDER cost of performing repair and maintenance services.

10.2 The AMC terms would not be considered as violated if any of (a) or (b) above takes place.

Should there be a fault in the operations of the system, the bidder, would not unreasonably assume that the causes lie with those components / software not acquired from them.

10.3 The bidder shall facilitate up-gradation of operation system of servers, increase storage/RAM to make it compatible to upgraded OS. Cost of this hardware shall be borne by the ICAR.

11. SUBCONTRACTING:

11.1 The BIDDER will not subcontract or permit anyone other than the BIDDER personnel to perform any of the work, services or other performance required of the BIDDER under this agreement without the prior written consent of the ICAR/PMC.

12. CONFIDENTIALITY:

12.1 The BIDDER acknowledges that all material and information which has and will come into its possession or knowledge in connection with this agreement or the performance thereof, whether consisting of confidential and proprietary data or not, whose disclosure to or use by third parties may be damaging or cause loss to ICAR/PMC will all times be held by it in strictest confidence and it shall not make use thereof other than for the performance of this agreement and to release it only to employees requiring such information, and not to release or disclose it to any other party. The BIDDER agrees to take appropriate action with respect to its employees to ensure that the obligations of non-use and non-disclosure of confidential information under this agreement are fully satisfied. In the event of any loss to the ICAR/PMC in divulging the information by the employees of the BIDDER, the ICAR/PMC shall be indemnified. The BIDDER agrees to maintain the confidentiality of the ICAR/PMC‟s information after the termination of the agreement also.

12.2 The BIDDER will treat as confidential all data and information about the Contract, obtained in the execution of this tender including any business, technical or financial information, in strict confidence and will not reveal such information to any other party.

Page 77 of 145

SLA Terms & Conditions

Qualification of Support Engineer:

The minimum qualification of the support engineer should be min. B.E. and should be as per details mentioned in Schedule „F‟ having work experience in Audio Video Systems.

Roles and responsibilities of operation staff and support Engineers:

(1)

The operation staff should be adequately positioned to run the complete facility and system without any glitch/hindrance

(2)

Should coordinate with all VC locations with whom conferencing is scheduled.

(3)

Should do preventive maintenance and testing of the AV system periodically.

(4)

Should monitor progress of meetings, status of AV system using the remote monitoring and control interface part.

(5)

Should know all the features (audio, video, control etc.) which are available in the proposed solution. During the term of the contract and the operation and maintenance period , the

BIDDER will maintain the equipment in perfect working order and condition and for this purpose will provide the following repairs and maintenance services: a) The BIDDER shall rectify any defects, faults and failures in the equipment and shall repair and replace worn out of defective parts including all plastic parts/lenses of the equipment during local working hours i.e. from 10.00 a.m. to 6.00 p.m. on weekdays and from 10.00a.m.to 4.00 p.m. on

Saturdays (other than ICAR/PMC holidays). However, the engineer will have to work on holidays and after office hours, if necessary. b) The BIDDER shall provide repair and maintenance service, in response to oral, including telephone notice by ICAR/PMC, within 2 hours (excluding intervening Sundays and ICAR/PMC holidays) after such intimation during the hours set forth in clause 1 (a) above. c) The BIDDER shall ensure that faults and failures intimated by ICAR/PMC as above are set right within 4 hours of being informed of the same. d) The BIDDER shall ensure that the full configuration of the equipment is available to

ICAR/PMC in proper working condition for minimum 99.5% of the time on a monthly basis. e) Preventive Maintenance: The BIDDER shall conduct Preventive Maintenance (including but not limited to inspection, testing, satisfactory execution of all diagnostics, cleaning and removal

Page 78 of 145

of dust and dirt from the interior and exterior of the equipment, and necessary repairing of the equipment) once within the first 15 days of the commencement of the maintenance period and once within the first fifteen days of every subsequent month during the currency of this

Agreement on a day and time to be mutually agreed upon. Notwithstanding the foregoing, the

BIDDER recognizes ICAR/PMC‟s operational needs and agrees that ICAR/PMC shall have the right to require the BIDDER to adjourn preventive Maintenance from any scheduled time to a date and time not later than 15 working days thereafter. f) All engineering changes generally adopted hereafter by the BIDDER for equipment similar to that covered by this AGREEMENT, shall be made to the equipment at no cost to ICAR/PMC. g) All repair and maintenance service described herein shall be performed by qualified maintenance engineers totally familiar with the equipment. h) The Bidder‟s representative shall maintain a register at its site in which, the Bidder‟s operator/supervisor shall record each event of failure and/or malfunction of the Equipment. The

BIDDER‟s engineer shall enter the details of the action taken in such register. Additionally, every-time a preventive or corrective maintenance is carried out, the BIDDER‟s engineer shall make, effect in duplicate, a Field Call Report which shall be signed by him and thereafter countersigned by the ICAR/PMC‟s official. The original of the Field Call Report shall be handed over to the ICAR/PMC‟s official.

6. The BIDDER‟s maintenance personnel shall be given access to the equipment when necessary for purposes of performing the repair and maintenance services indicated in this Agreement.

7. The equipment shall not be shifted to an alternate site and installed thereat during the currency of this Agreement without prior written notice to the BIDDER. However, if ICAR/PMC desires to shift the equipment to a new site and install it thereat urgently, the BIDDER shall be informed the same immediately. ICAR/PMC shall bear the charges for such shifting and reinstallation and the

BIDDER shall provide necessary assistance to ICAR/PMC in doing so.

8. If, in any month, the BIDDER does not fulfill the provisions of clauses 5(a), (b), (c) and (d), the penal action for failure to fulfill the commitments shall be initiated and the payment of proportionate maintenance charges due, if any, for that particular month will be at the sole consideration of ICAR/PMC without prejudice to the right of the ICAR/PMC either to make

Page 79 of 145

payment or terminate the contract. Payment owed to ICAR/PMC, if any, shall be returned on demand by the BIDDER within one month days from receipt of demand.

DESIGN INTENT / DESIGN BASIS REPORT

1. Introduction

The Auditorium at National Agriculture Science Center (NASC), PUSA, New Delhi is a large convention facility which will be used to hold large national and international conferences. The facility provides for a mixture of resources, ranging from large auditorium to meeting/conference rooms and training rooms. As part of an effort to make this facility truly world-class, technology (esp. user facing) will play an important role and therefore this note captures several aspects of Audio Visual and Integrated Communication Technology proposed in the building.

The design is proposed as per drawings provided by the architects. Suitable assumptions have been made in respect to elevations, sections and placement of various facilities. The design intent is tentative and provides an overview of designer‟s up-front vision and the goals of the project. The actual implementation may vary depending on the actual site requirements.

Further, the design intent shall evolve as the project moves through different stages, from finalization of design (BOQ), programming and construction of building occupancy and then renovations and retrofits.

The purpose of this document is to provide system planners, designers, owners of the project, a complete and coherent view of the project and hence ensure seamless design and implementation.

2. Design highlights

We have identified the following drivers to our design which add up to make the overall design philosophy of the project – a. Centralized control and remote monitoring: Better management and single point of troubleshooting in case any device fails, also a dedicated trained professional handling the system from one place, rather than having many people across to facilitate the troubleshooting and repairs, AMC, scheduled maintenance checks, backups etc. Thereby achieving operational excellence in AV. b. Integration of AV with IT and broad-cast standards so as to provide for a seamless operation of the facility.

Page 80 of 145

c. We understand the criticality and confidentiality of the content that will be presented in the facility, and therefore we will give priority to wired presentation connection, while wireless presentation will be used to view content from mobile

/ handheld devices. This strategy will allow for achieving Bring-Your-Own-

Device (BYOD) in the facility. d. Using a technology back-bone which is non-proprietary, and if it is, then the technology adoption is done by more than (04) manufacturers. e. Scalability and ease of up-gradation

3. Summary of Rooms and Program Requirement

Table I: Functional Overview and Room Quantity

# Floor Room Qty PPT SR AC VC IP CoS CS DS MI BGM

1 Basement Lounge 01 Y Y

2

3

Pre-function

& Lobby

01

VIP Lounge 01

Y

Y Y

4

5

6

7

8

Ground

First

Exhibition

Hall

Training

Rooms

Small

Conference

Rooms

Large

Conference

Rooms

Training

Rooms

01

02

02

01

02

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y*

Y* Y**

Y*

Y*

Y

Y

Y

Y

Y

9 Second Auditorium

Abbreviation

PPT

01 Y Y Y Y Y

Description

Y Y

Presentation with use of appropriate display solution and audio architecture

Y

SR

AC

VC

Y

Y

Y

Amplification of voice and music sources as well as from audio visual program sources.

Audio conferencing primarily based on VOIP and SIP® backbone unless otherwise specified

HD video conferencing with multiparty license and support for H.239

IP Interpretation System for simultaneous interpretation between users of different languages

Page 81 of 145

CoS

CS

DS

MI

Conferencing System (chair control etcetera)

Micro control processor based AV implementation which includes use of touch panel and interfaces

Digital display with signage which can be designed, networked and scheduled from central location

Media (Broadcast) Interactions / Information dissipation

BGM Background Music

* Shared resource between multiple rooms, kept in the control room.

** Only infrastructure ready.

4. Detailed overview of system and program requirement

4.1 Basement

4.1.1 Lounge:

Fig – 1: Floor Plan

Page 82 of 145

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

A wall mount monitor (LED back-lit) in the space will provide a visual communications platform for branding, news tickers, and emergency messages etcetera. Video from a networked signage player is reproduced on the display.

Background music is played through ceiling loudspeakers.

Using the H.264 encoder and its integration with signage player, this space can show preview of proceedings in either ground floor or second floor.

4.2 Ground Floor

4.2.1 Pre-function and Lobby:

Fig – 2: Floor Plan

Page 83 of 145

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

A wall mount monitor (LED back-lit) in the space will provide a visual communications platform for branding, news tickers, and emergency messages etcetera. Video from a networked signage player is reproduced on the display.

Background music is played through ceiling loudspeakers. This display will also broadcast information about meetings and agenda of several rooms.

4.2.2 VIP Lounge:

Using the H.264 encoder and its integration with signage player, this space can show preview of proceedings in either ground floor or second floor.

Fig – 3: Floor Plan

Page 84 of 145

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

A wall mount monitor (LED back-lit) in the space will provide a visual communications platform for branding, news tickers, and emergency messages etcetera. Video from a networked signage player is reproduced on the display.

Using the H.264 encoder and its integration with signage player, this space can show preview of proceedings in either ground floor or second floor.

4.2.3 Exhibition Hall:

Fig- 4: Plan & Elevation

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

Exhibition hall is a space where large groups can gather and it can be used as a multipurpose facility. The audience space is modular and the seating area is configurable.

From the stand point of AV, the space will support program requirement of presentation and applications similar to town hall.

Users will be able to present content through both wired and wireless connections and view information on large motorized front projection screens powered by high brightness ceiling mounted projectors installed. There are going to be (03) motorized projection screens on the front wall, which will be used as per the program requirement (for example, an instance could involve only one presenter in which case

(01) large screen at the center will be used, whereas in case of a large panel discussion, side (02) screens will be used. In addition to the main screen we will have

(02) motorized projection screens powered by high brightness ceiling mounted projectors installed, working as reinforcement screens in order to achieve adequate

Page 85 of 145

and appropriate viewing (due to limited ceiling height). The screen sizes have been calculated for general viewing with the factor of „8‟.

A presenter‟s console (lectern, to be fabricated by others) will be located at the front of the room and to one side of the front projection screen. The console will house connections for portable computers. Presenter will have (01) LED monitor as a confidence monitor, installed on a mobile trolley, in front of him to preview the content he is presenting without having to look back into the main large screen.

A wall plate with necessary input connectivity is provided for presenter to connect his source (e.g. laptop).

A wireless presentation gateway will provide presenters and audience with an option to Bring-Your-Own-Device (BYOD) for presentation in the facility. The presentation gateway is going to be connected to the network (LAN) of the facility.

Wireless handheld and wireless lavaliere/clip-on microphones are provided for audio pick up. Ceiling mounted antennas will ensure consistent and even microphone pick up across the space. Ceiling loudspeakers will be used to reinforce speech and program audio evenly across the entire space.

A ceiling mounted HD camera will capture the presenter and reinforce his video all the way till the rear end of the space. Another camera will be installed alongside the front projection screen to capture audience. Both the cameras are going to be operator controlled from the control room adjacent to the training Rooms. This room will be enabled for video conferencing by making use of a shared / common VC resource kept in the control room.

A wall mounted touch screen panel for system control will also be provided adjacent to the presenter‟s console.

AV equipment will be housed in an equipment rack in the control room on the ground floor. A wall mounted LED monitor outside the room will provide for information about the meeting and its agenda, content of which can be centrally managed over network.

4.2.4 Training Rooms (2 Nos):

Fig – 5: Floor Plan

Page 86 of 145

Fig – 6: Elevation with displays

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

Training room(s) are designed to provide space for presentations or training to large audience (200 persons in each room). The audience space consists of retractable seating positions.

Users will be able to present and view content on (02) motorized front projection screens powered by (02) ceiling mounted projectors. The screen sizes have been calculated for general viewing with the factor of „8‟.

A presenter‟s console (lectern, to be fabricated by others) will be located at the front of the room and to one side of the front projection screen. The console will house connections for portable computers. Presenter will have aLED monitor as a confidence monitor, installed on a custom mobile trolley, in front of him to preview the content he is presenting without having to look back into the main large screen.

A wall plate with necessary input connectivity is provided for presenter to connect his source (e.g. laptop).

A ceiling mounted camera will capture the presenter and reinforce his video all the way till the rear end of the space. Another camera will be installed alongside the front projection screen to capture audience. Both the cameras are going to be

Page 87 of 145

operator controlled from the control room adjacent to the training Rooms. This room will be enabled for video conferencing by making use of a shared / common VC resource kept in the control room.

Wireless handheld and wireless lavaliere/clip-on microphones are provided for audio pick up. Ceiling mounted antennas will ensure consistent and even microphone pick up across the space. Ceiling loudspeakers will be used to reinforce speech and program audio evenly across the training room.

A wireless presentation gateway will provide presenters and audience with an option to Bring-Your-Own-Device (BYOD) for presentation in the facility. The presentation gateway is going to be connected to the network (LAN) of the facility.

A wall mounted touch screen panel for system control will be provided.

AV equipment will be housed in an equipment rack in the control room on the ground floor.

4.2.5 Control Room:

Fig-7: Location of Control Room in floor-plan

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

The control room will have (03) LED monitors to preview content from the entire ground floor. It will also allow for initiation of recording.

Page 88 of 145

The equipment rack in the control room will house a large matrix switcher operations of the entire ground floor which in turn will be connected to the main control room on level two over fibre, thereby providing for absolute control over content from level two.

This room will allow for pushing content to level two over streaming and then over to broadcasters from a central location (Master Control Room of level two) over fibre optic to OB-Vans near the facility.

4.3 First Floor

4.3.1 Training Rooms (2 Nos):

Fig – 8: Plan

Fig – 9: Elevation

Page 89 of 145

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

Training room(s) are designed to provide space for presentations or training to large audience. The audience space consists of fixed seating positions.

Users will be able to present and view content on (02) motorized front projection screens powered by (02) ceiling mounted projectors. The screen sizes have been calculated for general viewing with the factor of „8‟.

A presenter‟s console (lectern, to be fabricated by others) will be located at the front of the room, and to one side of the front projection screen. The console will house connections for portable computers.

A wall plate with necessary input connectivity is provided for presenter to connect his source (e.g. laptop).

Wireless handheld and wireless lavaliere/clip-on microphones are provided for audio pick up and ceiling loudspeakers will be used to reinforce speech and program audio evenly across the training room. A wall mounted controller will be provided to control volume in the room. This room will be ready for wireless interpretation in terms of infrastructure provisioning. Equipment / active components will not be considered as part of day one purchase.

A wireless presentation gateway will provide presenters with an option to Bring-

Your-Own-Device (BYOD) for presentation in the facility. The presentation gateway is going to be connected to the network (LAN) of the facility.

4.3.2 Small Conference Rooms (02 Nos) and Large Conference Room:

Fig – 10: Floor Plan

Page 90 of 145

Fig – 11: Elevation oflarge conference room with displays

Fig – 12: Elevation of small conference room with displays

Page 91 of 145

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

Conference room(s) provides a space with three modes of operation: local presentation, audio conferencing and video conferencing. Here users can present and share ideas either locally or to remote offices via video and audio conference equipment. Users will be seated at a fixed table and view content on(01) large LED monitors. For the Large Conference Room & Small Conference Room, (02) additional LED back-lit monitors will be installed on the side walls to provide for video reinforcement. The screen sizes have been calculated for general viewing with the factor of „8‟.

Connectivity for laptops will be provided on the table to view and share content on the front projection screens.

The video conferencing system will have a camera with good optical zoom capability, installed between the two front projection screens.

Table top microphones will allow for near end audio pick up and ceiling loudspeakers will be used to reinforce speech and program audio evenly across the conference rooms.

A wireless presentation gateway will provide presenters with an option to Bring-

Your-Own-Device (BYOD) for presentation in the facility. The presentation gateway is going to be connected to the network (LAN) of the facility.

A table top wired touch panel, located at the fixed table will be used to control the system.

Page 92 of 145

The master control room will have a common equipment for the (02) small and the large conference rooms, which will allow for sharing of resources and also allow for keeping total number on equipment count low.

4.4 Second Floor

4.4.1 Auditorium:

Fig – 13: Floor Plan:

Fig – 14: Sectional view of the auditorium

Fig – 15: Elevation of direct LED-based display wall on elevation

Page 93 of 145

Fig – 16: 3D view using electro-acoustic prediction tool (EASE) to position loudspeakers

Fig – 17: 3D view using electro-acoustic prediction tool (EASE) to demonstrate broadband SPL

Fig – 18: 3D view using electro-acoustic prediction tool (EASE) to demonstrate STI

Page 94 of 145

Note: The diagrams shown above are indicative. Actual placement of equipment and type of equipment may vary as per site requirements.

The 1200 seat auditorium spans from the first floor to the second floor of the facility.

With the use of operable walls, the space can be split into three, with the capacity of

400 for each of the three spaces.

This space will be used for UN grade conferences, presentations, speech, prize distribution, performances etcetera. With such a varied program requirement and the modular nature of the interior design, the design philosophy of this is highly modular and centralized. The back-end equipment will be shared between the three spaces of the auditorium, thereby providing for seamless transition between different modes of operation.

When the operable walls are not in use, the focus of the entire audience is going to be towards the large direct-LED based display wall (approx. 7.6m (W) x 4.3m (H) of the main auditorium. This Direct LED wall will be installed at the rear wall of the stage and at a height of 6 feet above of the stage (so as to avoid any disturbance caused due to the presenter‟s movement on the stage).

There is a video wall that is made of thin-bezel 55” thin bezel LED back-lit monitors, stacked together in 4 x 4 array to from a large display for previewing content shown on the main display wall, which will have specific benefits such as higher contrast, sharper images, and lesser exposure to the ambient conditions such as light. In addition to the direct-LED based display wall and video wall in the main auditorium, we will have (02) motorized projection screens for reinforcement powered by (02) high brightness projectors installed in motorized lift in the ceiling, at the back which can also be used for local presentation within the space when the operable walls are closed. The back-end system will provide for absolute flexibility to present content on any of the three screens. The screen sizes have been calculated for general viewing with the factor of „8‟.

The projection screens and projectors can be operated at two different heights depending on the state of the operable walls. They will be higher when the walls are open, thereby providing clear view of the stage. They will be lower when the operable walls are closed and the screen will be used for local content dissipation.

Page 95 of 145

The main auditorium will have delegate units, one between (02) participants providing support for interpretation for up to five languages (selected through change of channel), volume control, mute etcetera.

The entire auditorium when combined, will enable the (03) distinct conferencing systems to work as one (this could be with the use of audio DSP or other means)..

The main auditorium will have support for 4 to 5 chairperson units on the stage.

When the partitions are closed, each space will support five language interpretation independently.

The sound system reinforcement will be distributed point source based solution where an L/C/R cluster will be formed for the main auditorium and a pair of loudspeakers will be installed in each of the two 400 capacity space at the back.

Subwoofers will be provided in addition for low end frequency support. Front fill

(M-H loudspeakers) will also be provided to achieve localization on the stage.

Monitor speakers will be planned to support performances.

A combination of wireless and wired microphones along with a large mixing console

(one for each space) will allow for control and operation of the sound system by sound engineer. The main auditorium will have digital stage box (digital snake) to bring multiple signals of audio to the mixing console.

The operator will have control over the stage lighting which will be integrated with

DMX control (provided and operated by others). Also, operator will control the operations of multiple cameras using operator controller unit from the control location. The operator will be aided through preview monitors and preview loudspeakers inside the control room to aid his operations and judgments.

Page 96 of 145

SECTION 6

DRAWINGS

Page 97 of 145

SECTION - 6

LIST OF DRAWINGS ENCLOSED

S.N. Description of Drawings

1 Ground Floor-Audio Schematic

2 Ground Floor-Audio Schematic

3 Ground Floor-Control Schematic

4 First Floor-Video Schematic

5 First Floor-Audio Schematic

6 First Floor-Control Schematic

7 Second Floor-Audio Schematic

8 NIL

9 Auditorium Ground Floor Plan

10 Auditorium Ground Floor Plan

11 Auditorium Ground Floor Plan

12 Auditorium Ground Floor Plan

13 Auditorium Ground Floor Plan

14 Auditorium Ground Floor Plan

15 Auditorium Ground Floor Plan

16 Auditorium Ground Floor Plan

17 Auditorium Ground Floor Plan

18 Auditorium Ground Floor Plan

19 Auditorium Ground Floor Plan

20 Auditorium First Floor Plan

21 Auditorium First Floor Plan

22 Auditorium First Floor Plan

23 Auditorium First Floor Plan

24 Auditorium First Floor Plan

25 Auditorium First Floor Plan

26 Auditorium First Floor Plan

27 Auditorium First Floor Plan

28 Auditorium First Floor Plan

29 Auditorium First Floor Plan

30 Auditorium First Floor Plan

31 Auditorium First Floor Plan

32 Auditorium First Floor Plan

33 Auditorium First Floor Plan

34 Auditorium First Floor Plan

35 Auditorium First Floor Plan

36 Auditorium First Floor Plan

37 Auditorium Second Floor Plan

Drawing No.

AV09.A1

AV0A.A1

AV0B.A1

AV10.A1

AV11.A1

AV12.A1

AV13.A1

AV14.A1

AV15.A1

AV16.A1

AV17.A1

AV18.A1

AV19.A1

AV1A.A1

AV1B.A1

AV1C.A1

AV01.A1

AV02.A1

AV03.A1

AV04.A1

AV05.A1

AV06.A1

AV08.A1

AV.A1

AV01.A1

AV02.A1

AV03.A1

AV04.A1

AV05.A1

AV06.A1

AV07.A1

AV08.A1

AV1D.A1

AV1E.A1

AV1F.A1

AV1G.A1

AV20.A1

Page 98 of 145

S.N. Description of Drawings

38 Auditorium Second Floor Plan

39 Auditorium Second Floor Plan

40 Auditorium Second Floor Plan

41 Auditorium Second Floor Plan

42 Auditorium Second Floor Plan

43 Auditorium Second Floor Plan

44 Auditorium Second Floor Plan

Page 99 of 145

Drawing No.

AV21.A1

AV22.A1

AV23.A1

AV24.A1

AV25.A1

AV26.A1

AV27.A1

EXHIBITION HALL

6' VGA WITH AUDIO CABLE

6' HDMI CABLE

**INSTALLED IN A WALL JB**

--

--

15P-HD

INPUTS

RGB IN

3.5MM

AUDIO IN

OUTPUTS

HDBASE-T

OUT

POWER

RJ45

PWR

-HDMI HDMI IN

-USB 2.0

USB HID

--

--

6' VGA WITH AUDIO CABLE

6' HDMI CABLE

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

--

--

--

**INSTALLED IN A WALL JB**

-15P-HD

INPUTS

RGB IN

OUTPUTS

RJ45

3.5MM

AUDIO IN

HDMI HDMI IN

USB 2.0

USB HID

POWER PWR

--

--

6' VGA WITH AUDIO CABLE

6' HDMI CABLE

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

**INSTALLED IN A WALL JB**

--

--

15P-HD

INPUTS

RGB IN

3.5MM

AUDIO IN

OUTPUTS

HDBASE-T

OUT

POWER

RJ45

PWR

-HDMI HDMI IN

-USB 2.0

USB HID

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

WALL LOCATION

--

--

**INSTALLED ON A CUSTOM

CEILING MOUNT**

INPUTS OUTPUTS

HD VIDEO

SELECT

CAMERA

SETTINGS

HDMI

YPbPr

RS-232

IP BASED

HDMI

HD-15

RJ45

--

--

--

3' HDMI CABLE

TO CAMERA

CONTROL CONSOLE

**INSTALLED ABOVE CEILING**

-HDMI

INPUTS

HDMI IN

OUTPUTS

RJ45 --

POWER PWR

FULL HD PTZ CAMERA (TYPE - C)

CEILING LOCATION

--

--

**INSTALLED ON A CUSTOM

WALL MOUNT SHELF**

INPUTS

HD VIDEO

SELECT

CAMERA

SETTINGS

OUTPUTS

HDMI

YPbPr

HDMI

HD-15

RJ45

--

--

--

--

3' HDMI CABLE

LAN RJ45

POWER PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

--

**INSTALLED IN A WALL JB**

HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45 --

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

POWER PWR

FULL HD PTZ CAMERA (TYPE - C)

--

WALL LOCATION

TRAINING ROOM # 01

6' VGA WITH AUDIO CABLE

6' HDMI CABLE

--

--

--

**INSTALLED IN A WALL JB**

15P-HD

INPUTS

RGB IN

3.5MM

AUDIO IN

OUTPUTS

HDBASE-T

OUT

POWER

RJ45

PWR

HDMI HDMI IN

-USB 2.0

USB HID

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

WALL LOCATION

--

--

**INSTALLED ON A CUSTOM

CEILING MOUNT**

INPUTS OUTPUTS

HDMI

YPbPr

RS-232

IP BASED

HDMI

HD-15

RJ45

--

--

--

3' HDMI CABLE

TO CAMERA

CONTROL CONSOLE

**INSTALLED ABOVE CEILING**

-HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45

--

--

--

PHNX

COM

PHNX IR

LAN RJ45

POWER PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

POWER PWR

FULL HD PTZ CAMERA (TYPE - C)

CEILING LOCATION

--

--

--

**INSTALLED ON A CUSTOM

WALL MOUNT SHELF**

INPUTS

SELECT

CAMERA

SETTINGS

OUTPUTS

HDMI HDMI

YPbPr

RS-232

IP BASED

HD-15

RJ45

--

--

--

3' HDMI CABLE

TO CAMERA

CONTROL CONSOLE

--

**INSTALLED IN A WALL JB**

HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45

--

--

--

PHNX COM

PHNX IR

LAN RJ45

POWER PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

POWER PWR

FULL HD PTZ CAMERA (TYPE - C)

--

WALL LOCATION

TRAINING ROOM # 02

6' VGA WITH AUDIO CABLE

6' HDMI CABLE

--

--

--

**INSTALLED IN A WALL JB**

15P-HD

INPUTS

RGB IN

3.5MM

AUDIO IN

OUTPUTS

HDBASE-T

OUT

POWER

RJ45

PWR

HDMI HDMI IN

-USB 2.0

USB HID

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

WALL LOCATION

--

--

**INSTALLED ON A CUSTOM

CEILING MOUNT**

INPUTS

HD VIDEO

SELECT

OUTPUTS

HDMI HDMI

YPbPr HD-15

RJ45

--

--

--

3' HDMI CABLE

POWER PWR

FULL HD PTZ CAMERA (TYPE - C)

CEILING LOCATION

--

--

--

**INSTALLED ON A CUSTOM

WALL MOUNT SHELF**

INPUTS

HD VIDEO

SELECT

CAMERA

SETTINGS

OUTPUTS

HDMI

YPbPr

HDMI

HD-15

RJ45

--

--

--

3' HDMI CABLE

POWER PWR

FULL HD PTZ CAMERA (TYPE - C)

--

WALL LOCATION

**INSTALLED ABOVE CEILING**

-HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45 --

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

H006

**INSTALLED IN A WALL JB**

HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45 --

CT00

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

D

C

A

B

6' HDMI CABLE

6' HDMI CABLE

FROM

AUDIO DSP

6' HDMI CABLE

6' HDMI CABLE

TO LAN

BY OTHERS

--

-RJ45

PWR

INPUTS

LAN

POWER

OUTPUTS

HDMI OUT

RGB OUT

HDMI

HD-15

AUDIO OUT 3.5MM

--

--

--

TO LAN

BY OTHERS

WIRELESS PRESENTATION GATEWAY

(TYPE A)

--

-RJ45

PWR

INPUTS

LAN

POWER

OUTPUTS

HDMI OUT

RGB OUT

AUDIO OUT

HDMI

HD-15

3.5MM

--

--

--

WIRELESS PRESENTATION GATEWAY

(TYPE A)

--

-RJ45

PWR

INPUTS

LAN

POWER

OUTPUTS

HDMI OUT

RGB OUT

AUDIO OUT

HDMI

HD-15

3.5MM

--

--

--

WIRELESS PRESENTATION GATEWAY

(TYPE A)

--

--

INPUTS

USB 2.0 USB

9PF RS232

OUTPUTS

HDMI

OUT

HDMI

ANALOG

R

COMP

L

VIDEO

RCA

RCA

RCA

--

--

--

--

-POWER

BLURAY PLAYER

PWR

--

--

--

--

INPUTS

PROP. CAMERA IN

HDMI HDMI IN

DVI/HDMI

IN

3.5MM

AUDIO IN

OUTPUTS

VIDEO

OUT 1

VIDEO

OUT 2

HDMI

HDMI

AUDIO 3.5MM

RS-232 8-MINI DIN

LAN

POWER

RJ-45

PWR

--

--

--

--

--

--

HD VIDEO CONFERENCING UNIT (TYPE A)

--

--

HDMI

INPUTS

HDMI IN

HDMI HDMI IN

OUTPUTS

HDMI

AUDIO PHNX

--

--

-PHNX AUDIO IN

LAN

POWER

RJ-45

PWR

H.264 STREAMING AND

RECORDING APPLIANCE

--

--

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

TO

AUDIO DSP

TO LAN

NETWORK SWITCH

6' HDMI CABLE

GROUND FLOOR AV RACKS

INPUTS OUTPUTS

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

RJ45

RJ45

RJ45

RJ45

RJ45

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

RJ45

RJ45

RJ45

RJ45

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

RJ45

RJ45 HDBASE-T BASED IN

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI IN

HDMI IN

HDMI IN

HDMI IN

HDMI IN

HDMI IN

HDMI IN

HDMI IN

01

02

03

04

HDBASE-T BASED OUT

HDBASE-T BASED OUT

HDBASE-T BASED OUT

HDBASE-T BASED OUT

05 HDBASE-T BASED OUT

06 HDBASE-T BASED OUT

07

08

HDBASE-T BASED OUT

HDBASE-T BASED OUT

09 HDBASE-T BASED OUT

10

HDBASE-T BASED OUT

11 HDBASE-T BASED OUT

12

HDBASE-T BASED OUT

13 HDBASE-T BASED OUT

14

15

16

HDMI OUT

HDMI OUT

17

18

HDMI OUT

HDMI OUT

19

HDMI OUT

HDMI OUT

20

21

HDMI OUT

HDMI

HDMI

HDMI

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

HDMI

HDMI

HDMI

HDMI

RJ45

RJ45

RJ45

RJ45

RJ45

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

B

D

A

C

FOR CONTROL

AND TO NETWORK SWITCH

--

--

--

AUDIO OUT PHNX

RJ45

9PF

PWR

LAN

RS232

POWER (230V)

AUDIO OUT PHNX

AUDIO OUT PHNX

DIGITAL MATRIX SWITCHER CHASSIS WITH

REDUNDANT POWER SUPPLY (CONFIG - A)

--

--

--

TO AUDIO DSP

TO AUDIO DSP

TO AUDIO DSP

6' HDMI CABLE

NETWORK

SWITCH

-RJ45

INPUTS

LAN

OUTPUTS

HDMI OUT

AUDIO OUT

HDMI

PHNX

--

--

--

-PHNX

PWR

RS232

POWER

H.264 STREAMING DECODER

TO AUDIO DSP

Page 100 of 145

35' HDMI CABLE

35' HDMI CABLE

35' HDMI CABLE

--

HDMI

INPUTS

HDMI IN

-PWR POWER

19" PREVIEW MONITOR

-HDMI

INPUTS

HDMI IN

-PWR POWER

19" PREVIEW MONITOR

-HDMI

INPUTS

HDMI IN

-PWR POWER

19" PREVIEW MONITOR

WALL MOUNTED

GROUND FLOOR CONTROL ROOM

EXHIBITION HALL

**INSTALLED ABOVE CEILING**

INPUTS OUTPUTS

-RJ45 HDMI OUT

COM

HDMI

PHNX

--

--

--

-RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

--

--

--

--

--

**CUSTOM CEILING MOUNT KIT**

INPUTS

HDMI

HD15

HDMI IN

RGB IN

RS-232C

RJ-45

SERIAL IN

LAN

PWR POWER

PROJECTOR

(TYPE A)

**INSTALLED ABOVE CEILING**

-RJ45

INPUTS

HDBASET

IN

OUTPUTS

HDMI OUT HDMI

COM PHNX

--

-RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**CUSTOM CEILING MOUNT KIT**

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

PROJECTOR

(TYPE A)

**INSTALLED ABOVE CEILING**

INPUTS OUTPUTS

-RJ45

HDBASET

IN

HDMI OUT HDMI

COM PHNX

-RJ45 LAN

IR PHNX --

-PWR POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

**CUSTOM CEILING MOUNT KIT**

INPUTS

--

--

--

--

--

HDMI

HD15

HDMI IN

RGB IN

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

PROJECTOR

(TYPE A)

**INSTALLED ABOVE CEILING**

INPUTS OUTPUTS

-RJ45

--

-RJ45

PWR

LAN

POWER

HDMI OUT

COM

HDMI

PHNX

IR PHNX

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

--

--

--

--

--

**CUSTOM CEILING MOUNT KIT**

INPUTS

HDMI

HD15

HDMI IN

RGB IN

RS-232C

RJ-45

SERIAL IN

LAN

PWR POWER

PROJECTOR

(TYPE B)

**INSTALLED ABOVE CEILING**

INPUTS OUTPUTS

-RJ45

HDBASET

IN

HDMI OUT HDMI --

COM PHNX --

--

-RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**CUSTOM CEILING MOUNT KIT**

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

PROJECTOR

(TYPE B)

**INSTALLED IN PRESENTER'S DESK**

-RJ45

INPUTS

HDBASET

IN

OUTPUTS

HDMI OUT HDMI --

COM PHNX --

--

-RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - B)

3' HDMI CABLE

--

**INSTALLED IN A FLOOR JB**

INPUTS OUTPUTS

RJ45

HDBASET

IN

HDMI OUT HDMI

COM PHNX

-RJ45 LAN

IR PHNX

-PWR POWER

--

HDBASET DIGITAL RECEIVER (TYPE - B)

CEILING LOCATION

**INSTALLED ON PRESENTER'S DESK**

-HDMI

INPUTS

HDMI IN

-PWR POWER

24" LED HD MONITOR

(PREVIEW MONITOR)

6' HDMI CABLE

CUSTOM CONTROL CABLE

PRESENTER'S DESK

MOBILE CART FOR CONFIDENCE MONITOR

INPUTS

--

--

--

--

--

HDMI

HD15

HDMI IN

RGB IN

RS-232C SERIAL IN

RJ-45 LAN

PWR POWER

40" LED BACK-LIT MONITOR

(CONFIDENCE MONITOR)

FLOOR LOCATION

TRAINING ROOM # 01

**INSTALLED ABOVE CEILING**

-RJ45

INPUTS OUTPUTS

HDMI OUT HDMI --

--

-RJ45

PWR

LAN

POWER

COM

IR

PHNX

PHNX

--

--

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

--

--

--

--

**CUSTOM CEILING MOUNT**

HDMI

INPUTS

HDMI IN

HD15 RGB IN

RS-232C

RJ-45

SERIAL IN

LAN

PWR POWER

PROJECTOR

(TYPE A)

**INSTALLED ABOVE CEILING**

INPUTS OUTPUTS

-RJ45

HDBASET

IN

HDMI OUT HDMI --

COM PHNX --

--

RJ45 LAN IR PHNX --

-PWR POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

--

**INSTALLED IN A FLOOR JB**

RJ45

INPUTS

HDBASET

IN

OUTPUTS

HDMI OUT

COM

HDMI

PHNX

-RJ45 LAN

IR PHNX

-PWR POWER

--

HDBASET DIGITAL RECEIVER (TYPE - B)

3' HDMI CABLE

CUSTOM CONTROL CABLE

--

--

--

--

--

**CUSTOM CEILING MOUNT**

INPUTS

HDMI

HD15

HDMI IN

RGB IN

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

PROJECTOR

(TYPE A)

CEILING LOCATION

6' HDMI CABLE

CUSTOM CONTROL CABLE

MOBILE CART FOR CONFIDENCE MONITOR

INPUTS

--

--

--

--

--

HDMI

HD15

HDMI IN

RGB IN

RS-232C

RJ-45

SERIAL IN

LAN

PWR POWER

40" LED BACK-LIT MONITOR

(CONFIDENCE MONITOR)

FLOOR LOCATION

TO LAN

BY OTHERS

INPUTS OUTPUTS

HDMI OUT

AUDIO OUT

HDMI

3.5MM

--

--

--

-RJ45

PWR

LAN

POWER

DIGITAL SIGNAGE

APPLIANCE

3' HDMI CABLE

--

--

**CUSTOM WALL MOUNT**

INPUTS

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C

RJ-45

SERIAL IN

LAN

PWR POWER

55" LED BACK-LIT MONITOR

(INFORMATION MONITOR)

WALL LOCATION

TRAINING ROOM # 02

**INSTALLED ABOVE CEILING**

-RJ45

INPUTS OUTPUTS

HDMI

HDMI OUT

COM PHNX

--

--

--

-RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

--

--

--

--

--

**CUSTOM CEILING MOUNT**

HDMI

INPUTS

HDMI IN

HD15 RGB IN

RS-232C

RJ-45

SERIAL IN

LAN

PWR POWER

PROJECTOR

(TYPE A)

**INSTALLED ABOVE CEILING**

INPUTS OUTPUTS

-RJ45

HDBASET

IN

HDMI OUT HDMI --

COM PHNX --

-RJ45 LAN

IR PHNX --

-PWR POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

--

**INSTALLED IN A FLOOR JB**

RJ45

INPUTS

HDBASET

IN

OUTPUTS

HDMI OUT HDMI

COM PHNX

--

--

-RJ45 LAN

IR PHNX --

-PWR POWER

HDBASET DIGITAL RECEIVER (TYPE - B)

TO LAN

BY OTHERS

INPUTS OUTPUTS

HDMI OUT

AUDIO OUT

HDMI

3.5MM

--

--

--

-RJ45

PWR

LAN

POWER

DIGITAL SIGNAGE

APPLIANCE

3' HDMI CABLE

CUSTOM CONTROL CABLE

--

--

--

--

--

**CUSTOM CEILING MOUNT**

INPUTS

HDMI

HD15

HDMI IN

RGB IN

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

PROJECTOR

(TYPE A)

CEILING LOCATION

6' HDMI CABLE

CUSTOM CONTROL CABLE

MOBILE CART FOR CONFIDENCE MONITOR

INPUTS

--

--

--

--

--

HDMI

HD15

HDMI IN

RGB IN

RS-232C

RJ-45

SERIAL IN

LAN

PWR POWER

40" LED BACK-LIT MONITOR

(CONFIDENCE MONITOR)

3' HDMI CABLE

FLOOR LOCATION

--

--

--

--

--

**CUSTOM WALL MOUNT**

INPUTS

HDMI

HD15

HDMI IN

RGB IN

RS-232C SERIAL IN

RJ-45 LAN

PWR POWER

55" LED BACK-LIT MONITOR

(INFORMATION MONITOR)

WALL LOCATION

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S.

DWG NO.:

AV01.A1

SHEET:

A3

SCALE:

1:1

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

GROUND FLOOR - AUDIO SCHEMATIC

SHEET TITLE :

SCHEMATIC DRAWING

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

BY THE CONTRACTOR OR ANY OTHER AGENCIES

5.

REFERRING TO THIS DRAWING.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

EXHIBITION HALL

UHF WIRELESS HANDHELD TRANSMITTER WITH

MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER WITH

MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER WITH

MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER WITH

MICROPHONE CAPSULE

UHF WIRELESS BODYPACK TRANSMITTER WITH

LAPEL MICROPHONE

UHF WIRELESS BODYPACK TRANSMITTER WITH

LAPEL MICROPHONE

OMNIDIRECTIONAL ANTENNA'S

A0

470-900 MHz

OMNIDIRECTIONAL ANTENNA'S

B0

470-900 MHz

OMNIDIRECTIONAL ANTENNA'S

A1

470-900 MHz

OMNIDIRECTIONAL ANTENNA'S

B1

470-900 MHz

50’ ANTENNA CABLE (TYPE - B)

50’ ANTENNA CABLE (TYPE - B)

100’ ANTENNA CABLE (TYPE - B)

100’ ANTENNA CABLE (TYPE - B)

TRAINING ROOM # 01

UHF WIRELESS HANDHELD TRANSMITTER WITH

MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER WITH

MICROPHONE CAPSULE

OMNIDIRECTIONAL ANTENNA'S

A0

470-900 MHz

OMNIDIRECTIONAL ANTENNA'S

B0

470-900 MHz

UHF WIRELESS BODYPACK TRANSMITTER WITH

LAPEL MICROPHONE

UHF WIRELESS BODYPACK TRANSMITTER WITH

LAPEL MICROPHONE

TRAINING ROOM # 02

50’ ANTENNA CABLE (TYPE - B)

50’ ANTENNA CABLE (TYPE - B)

UHF WIRELESS HANDHELD TRANSMITTER WITH

MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER WITH

MICROPHONE CAPSULE

OMNIDIRECTIONAL ANTENNA'S

A0

470-900 MHz

OMNIDIRECTIONAL ANTENNA'S

B0

470-900 MHz

UHF WIRELESS BODYPACK TRANSMITTER WITH

LAPEL MICROPHONE

UHF WIRELESS BODYPACK TRANSMITTER WITH

LAPEL MICROPHONE

50’ ANTENNA CABLE (TYPE - B)

50’ ANTENNA CABLE (TYPE - B)

BNC IN 1

BNC IN 2

OUT BNC B000

PASSIVE ANTENNA SPLITTER

/COMBINER KIT

BNC IN 1

BNC IN 2

OUT BNC B000

PASSIVE ANTENNA SPLITTER/

COMBINER KIT

BNC OUT IN BNC B000

UHF IN-LINE AMPLIFIER

BNC OUT IN BNC B000

UHF IN-LINE AMPLIFIER

BNC OUT IN BNC --

UHF IN-LINE AMPLIFIER

BNC OUT IN BNC --

UHF IN-LINE AMPLIFIER

BNC OUT IN BNC B000

UHF IN-LINE AMPLIFIER

IN BNC B000

BNC OUT

UHF IN-LINE AMPLIFIER

A00

B00

BNC

BNC

INPUTS

ANTENNA

A (IN)

ANTENNA

B (IN)

OUTPUTS

1 BNC

2

3

BNC

BNC

A1

A2

A3

-PWR POWER

4 BNC

BNC

1

2

3

BNC

BNC

4

BNC

A4

B1

B2

B3 A01

B01

BNC

BNC

ANTENNA

A (OUT)

ANTENNA

B (OUT)

B4

ACTIVE ANTENNA SPLITTER

A00

B00

BNC

BNC

INPUTS

ANTENNA

A (IN)

ANTENNA

B (IN)

OUTPUTS

1 BNC

2

3

BNC

BNC

A1

A2

A3

--

A01

B01

PWR

BNC

BNC

POWER

ANTENNA

A (OUT)

ANTENNA

B (OUT)

4

1

BNC

BNC

BNC

2

3

4

BNC

BNC

A4

B1

B2

B3

B4

ACTIVE ANTENNA SPLITTER

--

--

--

--

--

BNC

BNC

INPUTS

ANTENNA

A (IN)

ANTENNA

B (IN)

PWR POWER

BNC

BNC

ANTENNA

A (OUT)

ANTENNA

B (OUT)

OUTPUTS

1 BNC

2 BNC

3

4

BNC

BNC

1

2

BNC

BNC

3 BNC

4 BNC

--

--

--

--

--

--

--

--

ACTIVE ANTENNA SPLITTER

A00

B00

BNC

BNC

INPUTS

ANTENNA

A (IN)

ANTENNA

B (IN)

OUTPUTS

BNC

1

2 BNC

3

4

BNC

BNC

A1

A2

A3

A4

--

A01

B01

PWR

BNC

BNC

POWER

ANTENNA

A (OUT)

ANTENNA

B (OUT)

1

2

BNC

BNC

3

4

BNC

BNC

B1

B2

B3

B4

ACTIVE ANTENNA SPLITTER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR

POWER

PWR

A001

--

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR A001

POWER

PWR --

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR A001

POWER

PWR --

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR

POWER PWR

A001

--

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC

B

OUTPUTS

AUDIO XLR

POWER PWR

A001

--

DIVERSITY RECEIVER

--

--

INPUTS

BNC A

BNC B

OUTPUTS

AUDIO XLR

POWER PWR

A001

--

DIVERSITY RECEIVER

MUSIC SOURCE

CONTROL ROOM

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR

POWER

PWR

--

--

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR

POWER

PWR

--

--

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR

POWER

PWR

--

--

DIVERSITY RECEIVER

--

--

INPUTS

BNC A

BNC B

OUTPUTS

AUDIO XLR

POWER PWR

--

--

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR A001

POWER PWR --

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR A001

POWER PWR --

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR A001

POWER PWR --

DIVERSITY RECEIVER

--

--

BNC

INPUTS

A

BNC B

OUTPUTS

AUDIO XLR A001

POWER

PWR --

DIVERSITY RECEIVER

--

--

--

--

--

--

--

--

--

--

--

--

INPUT

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

MIC/LINE -1

MIC/LINE -2

MIC/LINE -3

MIC/LINE -4

MIC/LINE -5

MIC/LINE -6

MIC/LINE -7

MIC/LINE -8

LINE -9

LINE -10

LINE -11

LINE -12

OUTPUT

LINE OUT -1 PHNX

LINE OUT -2

LINE OUT -3

LINE OUT -4

LINE OUT -5

PHNX

PHNX

PHNX

PHNX

LINE OUT -6 PHNX

LINE OUT -7

LINE OUT -8

PHNX

PHNX

--

--

--

--

--

--

--

--

--

ETHERNET

RS-232

POWER

RJ-45

9PF

PWR

--

--

--

DIGITAL SIGNAL PROCESSOR (TYPE A)

GOOSENECK MICROPHONE

--

--

--

--

--

--

--

--

--

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

INPUT

MIC/LINE -1

MIC/LINE -2

MIC/LINE -3

MIC/LINE -4

MIC/LINE -5

MIC/LINE -6

MIC/LINE -7

MIC/LINE -8

LINE -9

OUTPUT

LINE OUT -1 PHNX

LINE OUT -2

LINE OUT -3

LINE OUT -4

LINE OUT -5

PHNX

PHNX

PHNX

PHNX

--

--

--

--

--

--

PHNX MIC IN - 10

--

-RJ45 LINK IN

ETHERNET

RS-232

POWER

RJ-45

9PF

PWR

--

--

--

DIGITAL SIGNAL PROCESSOR (TYPE A)

--

--

--

--

--

--

--

--

PHNX 1

PHNX

PHNX

PHNX

PHNX

PHNX 6

4

5

2

3

PHNX

PHNX

7

8

INPUT OUTPUT

1

2

PHNX

PHNX

3 PHNX

5

6

4

PHNX

PHNX

7

PHNX

PHNX

8 PHNX

POWER PWR

--

--

--

--

--

--

--

--

--

POWER AMPLIFIER (TYPE - E)

--

--

PHNX

PHNX

1

2

INPUT OUTPUT

POWER

1

2

PHNX

PHNX

PWR

--

--

--

POWER AMPLIFIER (TYPE C)

--

--

XLR

INPUTS

INPUT

PWR POWER

ACTIVE MONITOR LOUDSPEAKER

GROUND FLOOR AV RACK ROOM

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S

EXHIBITION HALL

S1

S1

S2

S2

S3

S1

S1

S2

S1

S1

S2

S2

S3

S2 S2

S3 S3

CEILING LOUDSPEAKERS

(TYPE - A)

S1

S1

S2 S2

S2

S1

S1

S3

CEILING LOCATION

S4

S5

TRAINING ROOM # 01

S4 S4 S4

S5 S5

CEILING LOUDSPEAKERS

(TYPE - A)

S4 S4

CEILING LOCATION

S6

S7

S8

TRAINING ROOM # 02

S6 S6 S6

S7 S7

CEILING LOUDSPEAKERS

(TYPE - A)

BASEMENT - LOUNGE

S8 S8 S8

S6

S8

S8 S8 S8

CEILING LOUDSPEAKERS

(TYPE - B)

S9

GROUND FLOOR - PREFUNCTION

S9 S9 S9 S9

S9

S10

S9 S9 S9

CEILING LOUDSPEAKERS

(TYPE - A)

GROUND FLOOR - VIP LOUNGE

S10 S10 S10

CEILING LOUDSPEAKERS

(TYPE - A)

S9

S6

CEILING LOCATION

CEILING LOCATION

CEILING LOCATION

CEILING LOCATION

DWG NO.:

AV02.A1

SHEET:

A3

SCALE:

1:1

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

GROUND FLOOR - AUDIO SCHEMATIC

SHEET TITLE :

SCHEMATIC DRAWING

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

BY THE CONTRACTOR OR ANY OTHER AGENCIES

5.

REFERRING TO THIS DRAWING.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

Page 101 of 145

RELAY PORT

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

5

6

3

4

1

2

7

8

RELAY PORT

5

6

3

4

1

2

7

8

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

RS-232

COM-1

COM-2

COM-3

COM-4

PHNX

PHNX

PHNX

COM-5

COM-6

PHNX

PHNX

PHNX

RS232 PORT

COM-1

COM-2

COM-3

PHNX

PHNX

PHNX

IR-SERIAL OUTPUT

S

3

G

S

4

G

5

S

G

6

S

G

1

2

S

G

S

G

7

S

G

8

S

G

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

RELAYS PORT

3

4

1

2

7

8

5

6

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

LAN A RJ45

CONTROL PROCESSOR

(CONFIG - C)

FROM LAN BY OTHERS

(TO CONTROL OTHER DEVICES SUCH AS MATRIX SWITCHER)

9PF RS-232

9PF RS-232

9PF RS-232

VIDEO CONFERENCING CODEC

AUDIO DSP (01)

HD CAMERA CONTROL CONSOLE

9PF RS-232

9PF RS-232

9PF RS-232

LIGHTING CONTROL (TR#01)

MUSIC SOURCE

BLURAY PLAYER

9PF RS-232

9PF RS-232

9PF RS-232

H.264 RECORDER

AUDIO DSP (02)

LIGHTING CONTROL (EXHIBITION HALL)

9PF RS-232

LIGHTING CONTROL (TR#02)

24 PORT POE

NETWORK SWITCH

MOTORIZED SCREEN # 1 (UP)

MOTORIZED SCREEN # 2 (UP)

MOTORIZED SCREEN # 3 (UP)

MOTORIZED SCREEN # 4 (UP)

MOTORIZED SCREEN # 5 (UP)

MOTORIZED SCREEN # 1 (UP)

MOTORIZED SCREEN # 2 (UP)

MOTORIZED SCREEN # 1 (UP)

MOTORIZED SCREEN # 2 (UP)

EXHIBITION HALL

MOTORIZED SCREEN # 1 (DOWN)

MOTORIZED SCREEN # 2 (DOWN)

MOTORIZED SCREEN # 3 (DOWN)

MOTORIZED SCREEN # 4 (DOWN)

MOTORIZED SCREEN # 5 (DOWN)

TRAINING ROOM # 01

MOTORIZED SCREEN # 1 (DOWN)

MOTORIZED SCREEN # 2 (DOWN)

TRAINING ROOM # 02

MOTORIZED SCREEN # 1 (DOWN)

MOTORIZED SCREEN # 2 (DOWN)

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S

DWG NO.:

AV03.A1

SHEET:

A3

SCALE:

1:1

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

EXHIBITION HALL WALL LOCATION

FROM NETWORK SWITCH

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

TRAINING ROOM # 01 WALL LOCATION

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

TRAINING ROOM # 02 WALL LOCATION

INPUTS

-RJ45 CAMERA CONTROL

OUTPUTS

CONTROL

PORT

9PF

--

TO CONTROL

PROCESSOR (OPTIONAL)

POWER PWR --

TO LAN

BY OTHERS

OPERATOR BASED CAMERA

CONTROLLER (TYPE - A)

--

--

INPUTS

RJ45 LAN

PWR POWER

OUTPUTS

VIDEO

OUT

AUDIO

OUT

DVI

3.5MM

--

--

HIGH-END PC

TABLE/DESK LOCATION

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

GROUND FLOOR - CONTROL SCHEMATIC

SHEET TITLE :

SCHEMATIC DRAWING

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

3.

RELEVANT DRAWINGS.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

5.

BY THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

Page 102 of 145

SMALL CONFERENCE ROOM # 01

LAPTOP

(OFE)

HDMI

15PHD

3.5 MM S

--

--

--

CABLE MANAGEMENT

BOX (TYPE-A)

LAPTOP

(OFE)

HDMI

15PHD

3.5 MM S

--

--

--

CABLE MANAGEMENT

BOX (TYPE-A)

3' HDMI CABLE

3' VGA + AUDIO MOLDED CABLE

**INSTALLED BELOW TABLE**

HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45

--

--

HD-15 RGB IN

3.5MM

AUDIO IN

--

--

PHNX

PHNX

COM

IR

LAN RJ45

POWER PWR

--

--

3' HDMI CABLE

3' VGA + AUDIO MOLDED CABLE

HDBASET DIGITAL TRANSMITTER (TYPE - A)

--

--

--

**INSTALLED BELOW TABLE**

INPUTS OUTPUTS

HDMI

HD-15

HDMI IN

RGB IN

3.5MM

AUDIO IN

RJ45 --

--

--

PHNX

PHNX

COM

IR

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL TRANSMITTER (TYPE - A)

TABLE LOCATION

**INSTALLED ON A

CUSTOM BUILT WALL MOUNT SHELF**

INPUTS OUTPUTS

--

--

SELECT

CAMERA

SETTINGS

HDMI

YPbPr

RS-232

IR-OUT

HDMI

HD-15

RJ45

RJ45

--

--

--

--

3' HDMI CABLE

POWER PWR --

FULL HD PTZ CAMERA (TYPE - B)

-HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45 --

--

--

PHNX

PHNX

COM

IR

LAN RJ45

POWER PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

WALL LOCATION

SMALL CONFERENCE ROOM # 02

LAPTOP

(OFE)

HDMI

15PHD

3.5 MM S

--

--

--

CABLE MANAGEMENT

BOX (TYPE-A)

LAPTOP

(OFE)

HDMI

15PHD

3.5 MM S

--

--

--

CABLE MANAGEMENT

BOX (TYPE-A)

3' HDMI CABLE

3' VGA + AUDIO MOLDED CABLE

**INSTALLED BELOW TABLE**

-HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45

--

--

HD-15 RGB IN

3.5MM

AUDIO IN

--

--

--

PHNX

PHNX

COM

IR

LAN RJ45

POWER PWR

--

--

HDBASET DIGITAL TRANSMITTER (TYPE - A)

3' HDMI CABLE

3' VGA + AUDIO MOLDED CABLE

--

--

**INSTALLED BELOW TABLE**

INPUTS OUTPUTS

RJ45 HDMI HDMI IN

HD-15 RGB IN

3.5MM

AUDIO IN

--

PHNX

PHNX

COM

IR

LAN

POWER

RJ45

PWR --

HDBASET DIGITAL TRANSMITTER (TYPE - A)

TABLE LOCATION

WALL LOCATION

**INSTALLED ON A

CUSTOM BUILT WALL MOUNT SHELF**

INPUTS OUTPUTS

--

--

SELECT

CAMERA

SETTINGS

HDMI

YPbPr

IR-OUT

POWER &

HD VIDEO

HDMI

HD-15

RJ45

RJ45

--

--

--

--

3' HDMI CABLE

POWER PWR --

FULL HD PTZ CAMERA (TYPE - B)

LARGE CONFERENCE ROOM

-HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45 --

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

LAPTOP

(OFE)

HDMI

15PHD

3.5 MM S

--

--

--

CABLE MANAGEMENT

BOX (TYPE-A)

LAPTOP

(OFE)

HDMI

15PHD

3.5 MM S

--

--

--

CABLE MANAGEMENT

BOX (TYPE-A)

LAPTOP

(OFE)

HDMI

15PHD

3.5 MM S

--

--

--

CABLE MANAGEMENT

BOX (TYPE-A)

3' HDMI CABLE

3' VGA + AUDIO MOLDED CABLE

--

--

**INSTALLED BELOW TABLE**

INPUTS

--

HDMI

HD-15

HDMI IN

RGB IN

3.5MM

AUDIO IN

OUTPUTS

HDBASE-T

OUT

RJ45 --

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

--

--

3' HDMI CABLE

3' VGA + AUDIO MOLDED CABLE

HDBASET DIGITAL TRANSMITTER (TYPE - A)

--

--

--

**INSTALLED BELOW TABLE**

INPUTS OUTPUTS

HDMI

HD-15

HDMI IN

RGB IN

3.5MM

AUDIO IN

RJ45 --

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL TRANSMITTER (TYPE - A)

3' HDMI CABLE

3' VGA + AUDIO MOLDED CABLE

--

--

--

**INSTALLED BELOW TABLE**

INPUTS OUTPUTS

HDMI HDMI IN

HD-15 RGB IN

3.5MM

AUDIO IN

HDBASE-T

OUT

RJ45 --

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL TRANSMITTER (TYPE - A)

TABLE LOCATION

WALL LOCATION

--

--

INPUTS

HD VIDEO

SELECT

OUTPUTS

HDMI

YPbPr

RS-232

IR-OUT

POWER &

HD VIDEO

HDMI

HD-15

RJ45

RJ45

--

--

--

--

POWER PWR --

FULL HD PTZ CAMERA (TYPE - B)

3' HDMI CABLE

TRAINING ROOM # 01

6' VGA + AUDIO CABLE

6' HDMI CABLE

-HDMI

INPUTS

HDMI IN

OUTPUTS

RJ45 --

--

--

PHNX

PHNX

COM

IR

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

--

--

--

--

**INSTALLED IN A WALL JB**

INPUTS OUTPUTS

15P-HD RGB IN

3.5MM

HDMI

AUDIO IN

HDMI IN

USB 2.0

USB HID

POWER

RJ45

PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

WALL LOCATION

TRAINING ROOM # 02

6' VGA + AUDIO CABLE

6' HDMI CABLE

--

--

--

**INSTALLED IN A WALL JB**

INPUTS

15P-HD RGB IN

3.5MM

HDMI

AUDIO IN

HDMI IN

OUTPUTS

HDBASE-T

OUT

POWER

RJ45

PWR

-USB 2.0

USB HID

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

WALL LOCATION

TO LAN

BY OTHERS

--

--

INPUTS

RJ45

PWR

LAN

POWER

OUTPUTS

HDMI OUT

RGB OUT

HDMI

HD-15

AUDIO OUT 3.5MM

--

--

--

TO LAN

BY OTHERS

WIRELESS PRESENTATION GATEWAY

(TYPE A)

--

--

INPUTS

RJ45

PWR

LAN

POWER

OUTPUTS

HDMI OUT

RGB OUT

HDMI

HD-15

AUDIO OUT 3.5MM

--

--

--

6' HDMI CABLE

6' HDMI CABLE

B

A 6' HDMI CABLE

6' HDMI CABLE

FROM

AUDIO DSP

TO LAN

BY OTHERS

--

--

INPUTS

RJ45

PWR

LAN

POWER

OUTPUTS

HDMI OUT HDMI

RGB OUT

AUDIO OUT

HD-15

3.5MM

--

--

--

WIRELESS PRESENTATION GATEWAY

(TYPE A)

TO LAN

BY OTHERS --

--

RJ45

PWR

INPUTS

LAN

POWER

OUTPUTS

HDMI OUT HDMI

RGB OUT

AUDIO OUT

HD-15

3.5MM

--

--

--

TO LAN

BY OTHERS

WIRELESS PRESENTATION GATEWAY

(TYPE A)

--

--

RJ45

PWR

INPUTS

LAN

POWER

OUTPUTS

HDMI OUT

RGB OUT

HDMI

HD-15

AUDIO OUT 3.5MM

--

--

--

WIRELESS PRESENTATION GATEWAY

(TYPE A)

--

--

INPUTS

USB 2.0 USB

9PF RS232

OUTPUTS

HDMI

OUT

R

HDMI

RCA

ANALOG

AUDIO L

COMP

VIDEO

RCA

RCA

--

--

--

--

-POWER

BLURAY PLAYER

PWR

--

--

INPUTS

PROP. CAMERA IN

HDMI

DVI/HDMI

HDMI IN

CONTENT

IN

3.5MM

AUDIO IN

OUTPUTS

VIDEO

OUT 1

VIDEO

OUT 2

AUDIO

HDMI

HDMI

3.5MM

RS-232 8-MINI DIN

LAN RJ-45

POWER PWR

--

--

--

--

--

--

HD VIDEO CONFERENCING UNIT (TYPE A)

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

TO

AUDIO DSP

6' HDMI CABLE

6' HDMI CABLE

TO LAN

BY OTHERS

FIRST FLOOR RACK

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

INPUTS OUTPUTS

RJ45 HDBASE-T BASED IN

RJ45

RJ45

HDBASE-T BASED IN

HDBASE-T BASED IN

RJ45 HDBASE-T BASED IN

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

RJ45

HDBASE-T BASED IN

HDMI HDMI IN

HDMI HDMI IN

HDMI HDMI IN

HDMI HDMI IN

HDMI HDMI IN

HDMI HDMI IN

HDMI HDMI IN

HDMI

HDMI IN

HDMI HDMI IN

HDMI HDMI IN

21

22

18

19

16

17

20

03

04

01

02

HDBASE-T BASED OUT

HDBASE-T BASED OUT

HDBASE-T BASED OUT

HDBASE-T BASED OUT

05

06

07

HDBASE-T BASED OUT

HDBASE-T BASED OUT

HDBASE-T BASED OUT

09

10

081 HDBASE-T BASED OUT

HDBASE-T BASED OUT

HDBASE-T BASED OUT

14

15

11

12

13

HDBASE-T BASED OUT

HDMI OUT

HDMI OUT

HDMI OUT

HDMI OUT

AUDIO OUT

AUDIO OUT

AUDIO OUT

PHNX

PHNX

PHNX

RJ45

RJ45

RJ45

RJ45

HDMI

HDMI

HDMI

HDMI

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

A

B

C

D

TO AUDIO DSP

TO AUDIO DSP

TO AUDIO DSP

FOR CONTROL

AND TO NETWORK SWITCH

--

--

--

RJ45

9PF

PWR

LAN

RS232

POWER (230V)

DIGITAL MATRIX SWITCHER CHASSIS WITH

REDUNDANT POWER SUPPLY (CONFIG - B)

6' HDMI CABLE

D

C 6' HDMI CABLE

6' HDMI CABLE

FROM

AUDIO DSP

--

--

HDMI

INPUTS

HDMI IN

HDMI HDMI IN

OUTPUTS

VIDEO

OUT 1

AUDIO

HDMI

PHNX

--

--

-PHNX AUDIO IN

LAN

POWER

RJ-45

PWR

H.264 STREAMING AND

RECORDING APPLIANCE

--

--

FROM

NETWORK

SWITCH

6' HDMI CABLE

--

INPUTS

RJ45 LAN

OUTPUTS

HDMI OUT

AUDIO OUT

HDMI

PHNX

--

--

--

--

PHNX

PWR

RS232

POWER

H.264 STREAMING DECODER

TO

AUDIO DSP

TO LAN

NETWORK SWITCH

TO AUDIO DSP

FIRST FLOOR CONTROL ROOM

Page 103 of 145

SMALL CONFERENCE ROOM # 01

**INSTALLED BEHIND DISPLAY**

OUTPUTS

-RJ45

INPUTS

HDBASET

IN

HDMI OUT HDMI --

-RJ45 LAN

COM

IR

PHNX

PHNX

--

--

-PWR POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

84" LED BACK-LIT MONITOR

**INSTALLED BEHIND DISPLAY**

INPUTS OUTPUTS

-RJ45

HDBASET

IN

HDMI OUT HDMI --

-RJ45 LAN

COM

IR

PHNX

PHNX

--

--

-PWR POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

65" LED BACK-LIT MONITOR

**INSTALLED BEHIND DISPLAY**

INPUTS OUTPUTS

--

RJ45

--

--

RJ45

PWR

LAN

POWER

HDMI OUT HDMI

COM PHNX

IR PHNX

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

65" LED BACK-LIT MONITOR

WALL LOCATION

SMALL CONFERENCE ROOM # 02

**INSTALLED BEHIND DISPLAY**

OUTPUTS

-RJ45

INPUTS

HDBASET

IN

HDMI OUT

COM

HDMI

PHNX

--

--

--

--

RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

84" LED BACK-LIT MONITOR

**INSTALLED BEHIND DISPLAY**

INPUTS OUTPUTS

--

--

RJ45

RJ45

HDBASET

IN

LAN

HDMI OUT

COM

IR

HDMI

PHNX

PHNX

--

--

--

-PWR POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

65" LED BACK-LIT MONITOR

**INSTALLED BEHIND DISPLAY**

INPUTS OUTPUTS

-RJ45

HDBASET

IN

HDMI OUT HDMI --

-RJ45 LAN

COM

IR

PHNX

PHNX

--

--

-PWR POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

65" LED BACK-LIT MONITOR

WALL LOCATION

LARGE CONFERENCE ROOM

**INSTALLED ABOVE CEILING**

OUTPUTS

-RJ45

INPUTS

HDBASET

IN

HDMI OUT

COM

HDMI

PHNX

--

--

--

--

RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

98" LED BACK-LIT MONITOR

**INSTALLED ABOVE CEILING**

OUTPUTS

-RJ45

INPUTS

HDBASET

IN

HDMI OUT

COM

HDMI

PHNX

--

--

--

--

RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

75" LED BACK-LIT MONITOR

--

--

-RJ45

INPUTS

HDBASET

IN

OUTPUTS

HDMI OUT

COM

HDMI

PHNX

RJ45

PWR

LAN

POWER

IR PHNX

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

CUSTOM CONTROL CABLE

TO LAN

BY OTHERS

**OEM APPROVED WALL MOUNT **

INPUTS

--

--

HDMI

HD15

HDMI IN

RGB IN

--

--

--

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

75" LED BACK-LIT MONITOR

CEILING LOCATION

TRAINING ROOM # 01

**INSTALLED ABOVE CEILING**

OUTPUTS

-RJ45

INPUTS

HDBASET

IN

HDMI OUT

COM

HDMI

PHNX

--

--

--

--

RJ45

PWR

LAN

POWER

IR PHNX --

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

TO LAN

BY OTHERS

--

--

--

--

--

**CUSTOM CEILING MOUNT **

INPUTS

HDMI

HD15

HDMI IN

RGB IN

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

PROJECTOR

(TYPE B)

CEILING LOCATION

TRAINING ROOM # 02

**INSTALLED ABOVE CEILING**

INPUTS OUTPUTS

--

RJ45

--

--

RJ45

PWR

LAN

POWER

HDMI OUT HDMI

COM PHNX

IR PHNX

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

TO LAN

BY OTHERS

--

--

--

--

--

**CUSTOM CEILING MOUNT **

INPUTS

HDMI

HD15

HDMI IN

RGB IN

RS-232C SERIAL IN

RJ-45

PWR

LAN

POWER

PROJECTOR

(TYPE B)

CEILING LOCATION

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S.

DWG NO.:

AV04.A1

SHEET:

A3

SCALE:

1:1

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

FIRST FLOOR - VIDEO SCHEMATIC

SHEET TITLE :

SCHEMATIC DRAWING

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

BY THE CONTRACTOR OR ANY OTHER AGENCIES

5.

REFERRING TO THIS DRAWING.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

SMALL CONFERENCE ROOM # 01

BOUNDARY LAYER MICROPHONE

(TYPE-A)

TOTAL 09 NOS

TABLE LOCATION

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

PHNX

PHNX

INPUTS

PHNX

PHNX

AEC IN 1

AEC IN 2

AEC IN 3

AEC IN 4

PHNX

PHNX

PHNX

PHNX

AEC IN 1

AEC IN 2

AEC IN 3

AEC IN 4

PHNX

PHNX

PHNX

PHNX

AEC IN 1

AEC IN 2

AEC IN 3

AEC IN 4

OUTPUTS

PROP.

TERMINO

LOGY

RJ45

BREAK-IN BOX (X3)

--

NETWORK SWITCH

SMALL CONFERENCE ROOM # 02

BOUNDARY LAYER MICROPHONE

(TYPE-A)

TOTAL 09 NOS

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

PHNX

INPUTS

AEC IN 1

PHNX

PHNX

PHNX

AEC IN 2

AEC IN 3

AEC IN 4

PHNX

PHNX

PHNX

PHNX

AEC IN 1

AEC IN 2

AEC IN 3

AEC IN 4

PHNX

PHNX

PHNX

PHNX

AEC IN 1

AEC IN 2

AEC IN 3

AEC IN 4

OUTPUTS

PROP.

LOGY

RJ45

BREAK-IN BOX (X3)

--

NETWORK SWITCH

TABLE LOCATION

BOUNDARY LAYER MICROPHONE

(TYPE-A)

TOTAL 15 NOS

LARGE CONFERENCE ROOM

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

XLR-M

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

PHNX

INPUTS

AEC IN 1

PHNX

PHNX

PHNX

AEC IN 2

AEC IN 3

AEC IN 4

PHNX

PHNX

PHNX

PHNX

AEC IN 1

AEC IN 2

AEC IN 3

AEC IN 4

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

AEC IN 1

AEC IN 2

AEC IN 3

AEC IN 4

AEC IN 1

AEC IN 2

AEC IN 3

AEC IN 4

OUTPUTS

PROP.

RJ45

BREAK-IN BOX (X4)

--

NETWORK SWITCH

TABLE LOCATION

TRAINING ROOM # 01

OMNIDIRECTIONAL ANTENNA'S

470-900 MHz

A0

50’ ANTENNA CABLE (TYPE - B)

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

-BNC

INPUTS

IN 1

OUTPUTS

OUT BNC

OUT BNC

PASSIVE ANTENNA SPLITTER/

COMBINER KIT

--

--

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

OMNIDIRECTIONAL ANTENNA'S

470-900 MHz

B0

100’ ANTENNA CABLE (TYPE - B)

--

INPUTS

BNC IN 1

OUTPUTS

OUT

OUT

BNC

BNC

PASSIVE ANTENNA SPLITTER/

COMBINER KIT

--

--

CEILING LOCATION

TRAINING ROOM # 02

OMNIDIRECTIONAL ANTENNA'S

470-900 MHz

A0

50’ ANTENNA CABLE (TYPE - B)

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

--

INPUTS

BNC IN 1

OUTPUTS

OUT BNC

OUT BNC

PASSIVE ANTENNA SPLITTER/

COMBINER KIT

--

--

OMNIDIRECTIONAL ANTENNA'S

470-900 MHz

B0

100’ ANTENNA CABLE (TYPE - B)

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

-BNC

INPUTS

IN 1

OUTPUTS

OUT BNC

OUT BNC

PASSIVE ANTENNA SPLITTER/

COMBINER KIT

--

--

CEILING LOCATION

--

--

INPUTS

BNC A

BNC B

OUTPUTS

AUDIO XLR

POWER PWR

--

--

DIVERSITY RECEIVER

--

--

INPUTS

BNC A

BNC B

OUTPUTS

AUDIO XLR

POWER

PWR

--

--

DIVERSITY RECEIVER

--

--

INPUTS

BNC A

BNC B

OUTPUTS

AUDIO XLR

POWER PWR

--

--

DIVERSITY RECEIVER

--

--

INPUTS

BNC A

BNC B

OUTPUTS

AUDIO XLR

POWER PWR

--

--

DIVERSITY RECEIVER

FROM MATRIX SWITCHER

AUDIO OUT

FROM MATRIX SWITCHER

AUDIO OUT

FROM MATRIX SWITCHER

AUDIO OUT

FROM MATRIX SWITCHER

AUDIO OUT

FROM MATRIX SWITCHER

AUDIO OUT

FROM VC CODEC

AUDIO OUT

NETWORK SWITCH

INPUT

--

--

--

--

--

--

--

--

--

--

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

MIC/LINE -1

MIC/LINE -2

MIC/LINE -3

MIC/LINE -4

MIC/LINE -5

MIC/LINE - 6

MIC/LINE - 7

MIC/LINE - 8

PHNX

PHNX

MIC/LINE - 9

MIC/LINE - 10

OUTPUT

LINE OUT -1

LINE OUT -2

LINE OUT -3

LINE OUT -4

PHNX

PHNX

PHNX

PHNX

--

--

--

--

PROP.

TERMINO

LOGY

RJ45 --

--

ETHERNET

RS-232

POWER

RJ-45

9PF

PWR

RJ45

PROP.

TERMINO

LOGY

DIGITAL SIGNAL PROCESSOR (TYPE B)

--

--

--

FIRST FLOOR AV RACKS

INPUT OUTPUT

LINE OUT -2 PHNX

LINE OUT -3

LINE OUT -4

PHNX

PHNX

LINE OUT -1 PHNX

LINE OUT -2

LINE OUT -3

LINE OUT -4

LINE OUT -1

PHNX

PHNX

PHNX

PHNX

LINE OUT -2

LINE OUT -3

LINE OUT -4

PHNX

PHNX

PHNX

PROP.

TERMINO

LOGY

RJ-45

--

--

--

--

--

--

--

--

--

--

--

--

--

ETHERNET

RS-232

POWER

RJ-45

9PF

PWR

RJ45

PROP.

TERMINO

LOGY

DIGITAL SIGNAL PROCESSOR (TYPE B)

--

--

--

TO VC CODEC

AUDIO IN

Page 104 of 145

--

--

PHNX

PHNX

1

2

INPUT OUTPUT

1

2

PHNX

PHNX

--

--

POWER PWR

--

POWER AMPLIFIER (TYPE - C)

--

--

PHNX

PHNX

1

2

INPUT OUTPUT

1

2

PHNX

PHNX

--

--

POWER PWR --

POWER AMPLIFIER (TYPE - C)

--

--

--

--

--

--

--

--

PHNX

PHNX

1

2

PHNX

PHNX

PHNX

PHNX

5

6

3

4

PHNX

PHNX

7

8

INPUT OUTPUT

1

2

PHNX

PHNX

3

PHNX

4

PHNX

5

PHNX

6

PHNX

7 PHNX

8 PHNX

POWER PWR

--

--

--

--

--

--

--

--

--

POWER AMPLIFIER (TYPE - A)

--

--

PHNX

PHNX

1

2

INPUT OUTPUT

1

2

PHNX

PHNX

POWER

PWR

--

--

--

POWER AMPLIFIER (TYPE - C)

FIRST FLOOR CONTROL ROOM

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S.

SMALL CONFERENCE ROOM # 01

S1

S1

S1 S1

S1 S1

CEILING LOUDSPEAKERS

(TYPE B)

DWG NO.:

AV05.A1

SHEET:

A3

SCALE:

1:1

CEILING LOCATION

SMALL CONFERENCE ROOM # 02

S1

S1

S1 S1

S1 S1

CEILING LOUDSPEAKERS

(TYPE B)

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

CEILING LOCATION

LARGE CONFERENCE ROOM

S1

S1

S1

S1

S1

S1

S1

S1

CEILING LOUDSPEAKERS

(TYPE B)

CEILING LOCATION

TRAINING ROOM # 01

S1 S1 S1

S2 S2 S2

CEILING LOUDSPEAKERS

(TYPE B)

CEILING LOCATION

TRAINING ROOM # 02

S1 S1 S1

S2 S2

CEILING LOUDSPEAKERS

(TYPE B)

CEILING LOCATION

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

FIRST FLOOR - AUDIO SCHEMATIC

SHEET TITLE :

SCHEMATIC DRAWING

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

BY THE CONTRACTOR OR ANY OTHER AGENCIES

5.

REFERRING TO THIS DRAWING.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

17

18

PHNX

PHNX

1

2

PHNX

PHNX

17

18

PHNX

PHNX

1

2

PHNX

PHNX

17

30

PHNX

PHNX

LAN A RJ45

CONTROL PROCESSOR

(CONFIG - B)

RS-232

COM-1

COM-2

COM-3

COM-4

COM-5

COM-6

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

IR-SERIAL OUTPUT

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

7

S

G

8

S

G

S

1

G

S

2

G

3

S

G

4

S

G

5

S

G

S

6

G

RELAYS

3

4

1

2

7

8

5

6

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

RELAY PORT

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

5

6

3

4

7

8

1

2

I/O PORTS

1

2

PHNX

PHNX

9PF

9PF

9PF

RS-232

RS-232

RS-232

VIDEO CONFERENCING CODEC

LIGHTING CONTROL (SMALL CONF. # 01)

LIGHTING CONTROL (LARGE CONF.)

SMALL CONF. ROOM 01 - 01ST MICROPHONE (TYPE-A)

SMALL CONF. ROOM 01 - 09TH MICROPHONE (TYPE-A)

SMALL CONF. ROOM 02 - 01ST MICROPHONE (TYPE-A)

SMALL CONF. ROOM 02 - 09TH MICROPHONE (TYPE-A)

LARGE CONF. ROOM - 01ST MICROPHONE (TYPE-A)

LARGE CONF. ROOM - 15TH MICROPHONE (TYPE-A)

FROM LAN BY OTHERS

(CONTROL 32X32 SWITCHER OVER ETHERNET)

9PF RS-232

9PF RS-232

AUDIO DSP (01)

LIGHTING CONTROL (SMALL CONF. # 02)

24 PORT POE

NETWORK SWITCH

--

INPUTS

IEC POWER

OUTPUTS

POWER PHNX

POWER SUPPLY

OVER CATEGORY CABLE

--

--

INPUTS

IEC POWER

OUTPUTS

POWER PHNX

POWER SUPPLY

OVER CATEGORY CABLE

--

Page 105 of 145

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S.

DWG NO.:

AV06.A1

SHEET:

A3

SCALE:

1:1

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

SMALL CONFERENCE # 01

PROJECT MANAGEMENT CONSULTANTS

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

SMALL CONFERENCE # 02

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

LARGE CONFERENCE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

RJ00

**INSTALLED IN A WALL JB**

OUTPUTS

RJ45

INPUTS

HDBASET

IN

COM 1 PHNX CT00

PHNX POWER

IR 1

IR 2

PHNX

PHNX

1

RELAY

PORT 2

3

PHNX

PHNX

PHNX

--

--

--

--

--

--

WALL MOUNT BUTTON PANEL

WITH CONTROLLER (TYPE - B)

TO MOTORIZED SCREEN # 1

TO LAN

BY OTHERS

RJ00

**INSTALLED IN A WALL JB**

INPUTS OUTPUTS

RJ45 COM 1 PHNX CT00

-PHNX POWER

IR 1 PHNX

IR 2 PHNX

1

RELAY

PORT 2

3

PHNX

PHNX

PHNX

--

--

--

--

--

WALL MOUNT BUTTON PANEL

WITH CONTROLLER (TYPE - B)

TO MOTORIZED SCREEN # 1

TRAINING ROOM # 01

TRAINING ROOM # 02

CLIENT:

DRAWING TITLE:

FIRST FLOOR - CONTROL SCHEMATIC

SHEET TITLE :

SCHEMATIC DRAWING

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

3.

RELEVANT DRAWINGS.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

BY THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

MAIN AUDITORIUM

6' HDMI CABLE

6' VGA + AUDIO CABLE

**INSTALLED IN A FLOOR JB**

INPUTS OUTPUTS

-HDMI HDMI IN HDBASE-T

OUT

RJ45

--

--

HD-15

3.5MM

RGB IN

AUDIO IN

--

--

--

PHNX COM

PHNX IR

LAN RJ45

POWER PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

**INSTALLED IN A FLOOR JB**

INPUTS OUTPUTS

-HDMI HDMI IN HDBASE-T

OUT

RJ45

--

--

HD-15

3.5MM

RGB IN

AUDIO IN

--

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

**INSTALLED IN A FLOOR JB**

INPUTS OUTPUTS

HDMI HDMI IN HDBASE-T

OUT RJ45

HD-15 RGB IN

3.5MM

AUDIO IN

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR --

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

STAGE LOCATION

--

--

**INSTALLED ON A

CUSTOM SHELF**

INPUTS OUTPUTS

HDMI HDMI HD VIDEO

SELECT

CAMERA

SETTINGS

YPbPr

RS-232

IR-OUT

POWER &

HD VIDEO

HD-15

RJ45

RJ45

--

--

--

--

3' HDMI CABLE

POWER PWR

FULL HD PTZ CAMERA (TYPE - E)

--

**INSTALLED IN A WALL JB**

INPUTS OUTPUTS

-HDMI HDMI IN HDBASE-T

OUT

RJ45

LAN RJ45

POWER PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

--

--

**INSTALLED ON A

CUSTOM SHELF**

INPUTS OUTPUTS

HD VIDEO

SELECT

CAMERA

SETTINGS

HDMI

YPbPr

RS-232

IR-OUT

POWER &

HD VIDEO

HDMI

HD-15

RJ45

RJ45

--

--

--

--

3' HDMI CABLE

POWER PWR

FULL HD PTZ CAMERA (TYPE - E)

--

**INSTALLED IN A WALL JB**

INPUTS

-HDMI HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45 --

LAN

POWER

RJ45

PWR

--

--

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

--

--

**INSTALLED ON A

CUSTOM SHELF**

INPUTS OUTPUTS

HD VIDEO

SELECT

CAMERA

HDMI HDMI

SETTINGS

YPbPr

RS-232

HD-15

RJ45

IR-OUT

POWER &

HD VIDEO

RJ45

--

--

--

--

3' HDMI CABLE

POWER PWR

FULL HD PTZ CAMERA (TYPE - E)

--

WALL LOCATION

**INSTALLED IN A WALL JB**

INPUTS OUTPUTS

-HDMI HDMI IN HDBASE-T

OUT RJ45

LAN

POWER

RJ45

PWR --

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

L.H.S. AUDITORIUM

6' HDMI CABLE

6' VGA + AUDIO CABLE

**INSTALLED IN A FLOOR JB**

INPUTS

--

--

HDMI

HD-15

HDMI IN

RGB IN

OUTPUTS

HDBASE-T

OUT

RJ45

-3.5MM

AUDIO IN

--

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

--

--

STAGE LOCATION

**INSTALLED ON A

CUSTOM SHELF**

INPUTS OUTPUTS

HDMI HD VIDEO

SELECT

CAMERA

SETTINGS

YPbPr

RS-232

IR-OUT

POWER &

HD VIDEO

HDMI

HD-15

RJ45

RJ45

POWER PWR

FULL HD PTZ CAMERA (TYPE - E)

3' HDMI CABLE

**INSTALLED IN A WALL JB**

INPUTS OUTPUTS

-HDMI HDMI IN HDBASE-T

OUT

RJ45

--

--

HD-15 RGB IN

3.5MM

AUDIO IN

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

WALL LOCATION

R.H.S. AUDITORIUM

6' HDMI CABLE

6' VGA + AUDIO CABLE

**INSTALLED IN A FLOOR JB**

INPUTS OUTPUTS

-HDMI HDMI IN HDBASE-T

OUT

RJ45

--

--

HD-15

3.5MM

RGB IN

AUDIO IN

--

--

PHNX COM

PHNX IR

LAN RJ45

POWER PWR

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

STAGE LOCATION

--

--

**INSTALLED ON A

CUSTOM SHELF**

INPUTS OUTPUTS

HDMI HDMI HD VIDEO

SELECT

CAMERA

SETTINGS

YPbPr

RS-232

IR-OUT

POWER &

HD-15

RJ45

RJ45

HD VIDEO

3' HDMI CABLE

TO CAMERA

CONTROL CONSOLE

POWER PWR

FULL HD PTZ CAMERA (TYPE - E)

WALL LOCATION

--

--

**INSTALLED IN A WALL JB**

INPUTS

--

--

HDMI

HD-15

HDMI IN

RGB IN

OUTPUTS

HDBASE-T

OUT

RJ45

-3.5MM

AUDIO IN

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR --

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - D)

C 6' HDMI CABLE

D 6' HDMI CABLE

TO LAN

BY OTHERS

RJ45

PWR

INPUTS

LAN

POWER

OUTPUTS

HDMI OUT

RGB OUT

HDMI

HD-15

AUDIO OUT 3.5MM

WIRELESS PRESENTATION GATEWAY

(TYPE-A)

RJ45

PWR

INPUTS

LAN

POWER

OUTPUTS

HDMI OUT HDMI

RGB OUT

AUDIO OUT

HD-15

3.5MM

TO LAN

BY OTHERS

WIRELESS PRESENTATION GATEWAY

(TYPE-A)

RJ45

PWR

INPUTS

LAN

POWER

OUTPUTS

HDMI OUT

RGB OUT

HDMI

HD-15

AUDIO OUT 3.5MM

WIRELESS PRESENTATION GATEWAY

(TYPE-A)

--

USB 2.0 USB

9PF

INPUTS

RS232

OUTPUTS

HDMI

HDMI

OUT

ANALOG

AUDIO

R

L

RCA

RCA

COMP

VIDEO RCA

POWER PWR

BLURAY PLAYER

--

--

B

A 6' HDMI CABLE

6' HDMI CABLE

FROM

AUDIO DSP

--

--

INPUTS

HDMI HDMI IN

PHNX AUDIO IN

OUTPUTS

3G-SDI OUT BNC

RS232 PHNX --

-PWR POWER

HDMI TO SDI SCALER

TO LAN

BY OTHERS

--

INPUTS

PROP. CAMERA IN

HDMI HDMI IN

OUTPUTS

VIDEO

OUT 1 HDMI

VIDEO

OUT 2 HDMI

-DVI/HDMI CONTENT

IN

PHNX AUDIO IN

AUDIO 3.5MM

RS-232

LAN

8-MINI DIN

RJ-45

POWER PWR

HD VIDEO CONFERENCING UNIT

(TYPE A)

--

--

--

--

--

--

--

BNC

BNC

INPUTS

3G-SDI

COMP.

15P-HD RGB IN

HDMI HDMI IN

VIDEO

OUT 1 HDMI --

AUDIO OUT 3.5MM

--

--

--

USB2.0 USB

PHNX AUDIO IN

LAN

POWER

RJ-45

PWR

H.264 STREAMING AND

RECORDING APPLIANCE

--

--

RJ45

INPUTS

LAN

PWR POWER

OUTPUTS

VIDEO

DVI

OUT

AUDIO

OUT 3.5MM

--

--

DESKTOP PC

WITH CONFERENCING SOFTWARE

(DISPLAY, KEYBOARD & MOUSE)

6' HDMI CABLE

6' HDMI CABLE

TO

AUDIO DSP

TO LAN

BY OTHERS

6' HDMI CABLE

6' HDMI CABLE

TO LAN

BY OTHERS

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

3' DVI TO HDMI MOLDED CABLE

HDMI

INPUTS

HDMI IN

HD-15 RGB IN

OUTPUTS

HDBASE-T

OUT

RJ45

PHNX COM

PHNX IR

LAN RJ45

POWER PWR

HDBASET DIGITAL WALL PLATE

TRANSMITTER (TYPE - E)

AV ROOM ON SIDE OF AUDITORIUM

SECOND FLOOR RACK MAIN AUDITORIUM

CONTROL UNIT

MAIN LED WALL (01)

MULTI MODE FIBER EXTENDER

INPUTS OUTPUTS

OUT 1

OUT 2

DVI-I

DVI-I

OUT 3

OUT 4

DVI-I

DVI-I

--

--

--

--

--

--

--

--

HDMI

HDMI

HDMI

HDMI

HDMI - 1

HDMI - 2

HDMI - 3

HDMI - 4

LAN

RS-232

RJ-45

9PF

--

--

POWER PWR --

VIDEOWALL PROCESSING SYSTEM

6' HDMI CABLE

--

--

--

HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45

HD-15 RGB IN

3.5MM

AUDIO IN

--

--

PHNX COM

PHNX IR

--

LAN RJ45

POWER PWR --

--

HDBASET DIGITAL TRANSMITTER

(TYPE - A)

6' HDMI CABLE

--

--

--

HDMI

INPUTS

HDMI IN

HD-15 RGB IN

3.5MM

AUDIO IN

OUTPUTS

HDBASE-T

OUT

RJ45

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR --

--

--

HDBASET DIGITAL TRANSMITTER

(TYPE - A)

6' HDMI CABLE

--

--

--

HDMI

INPUTS

HDMI IN

OUTPUTS

HDBASE-T

OUT

RJ45

HD-15 RGB IN

3.5MM

AUDIO IN

--

--

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR

--

--

--

HDBASET DIGITAL TRANSMITTER

(TYPE - A)

6' HDMI CABLE HDMI

INPUTS

HDMI IN

HD-15 RGB IN

3.5MM

AUDIO IN

OUTPUTS

HDBASE-T

OUT

RJ45

PHNX COM

PHNX IR

LAN

POWER

RJ45

PWR --

--

--

HDBASET DIGITAL TRANSMITTER

(TYPE - A)

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

6' HDMI CABLE

E

G

TO NETWORK SWITCH

6' HDMI CABLE

INPUTS OUTPUTS

RJ45

RJ45

RJ45

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

HDBASE-T BASED IN

01

02

HDMI OUT

HDMI OUT

HDMI OUT 03

04 HDMI OUT

HDMI OUT 05

06 HDBASE-T BASED OUT

07 HDBASE-T BASED OUT

08 HDBASE-T BASED OUT

HDMI

HDMI RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

HDBASE-T BASED IN

HDBASE-T BASED IN

09 HDBASE-T BASED OUT

10 HDBASE-T BASED OUT

-RJ45 HDBASE-T BASED IN

-RJ45 HDBASE-T BASED IN

RJ45 HDBASE-T BASED IN

HDMI HDMI IN

RJ45

RJ45

--

--

--

--

--

--

--

--

HDMI

--

--

HDMI

--

HDMI

HDMI

HDMI

HDMI IN

HDMI IN

HDMI HDMI IN

HDMI

HDMI IN

HDMI IN

HDMI IN

HDMI IN

HDMI HDMI IN

HDMI HDMI IN

11 HDBASE-T BASED OUT

12

13

14

15

16

17

18

19

20

21

22

23

HDMI OUT

HDMI OUT

HDMI OUT

HDBASE-T BASED OUT

HDBASE-T BASED OUT

HDMI OUT

HDMI OUT

HDMI OUT

HDMI OUT

HDMI OUT

HDMI OUT

--

--

--

24

25

26

27

28

29

30

31

HDMI OUT

HDMI OUT

HDMI OUT

HDMI OUT

HDMI OUT

HDMI OUT

HDMI

HDMI

RJ45 LAN AUDIO OUT PHNX

AUDIO OUT PHNX 9PF

PWR

RS232

POWER (230V)

AUDIO OUT PHNX

DIGITAL MATRIX SWITCHER CHASSIS

WITH REDUNDANT POWER SUPPLY

(CONFIG - C)

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

HDMI

RJ45

RJ45

HDMI

HDMI

RJ45

RJ45

RJ45

RJ45

HDMI

HDMI

HDMI

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

12' HDMI CABLE

A

C

E

G

I

K

TO AUDIO DSP

TO AUDIO DSP

TO AUDIO DSP

J

F

H

B

D

6' HDMI CABLE

F

6' HDMI CABLE

6' HDMI CABLE

--

--

--

--

--

INPUTS

HD15P RGB 1

HD15P RGB 2

HDMI

HDMI

HDMI

HDMI 3

HDMI 4

HDMI 5

OUTPUTS

HDMI OUT HDMI

--

RGB OUT HD15P --

-RJ45 LAN

SEAMLESS SWITCHER

POWER PWR --

6' HDMI CABLE

FROM

NETWORK

SWITCH

RJ45 LAN

PHNX RS232

PWR POWER

HDMI OUT

AUDIO OUT

HDMI

PHNX

H.264 STREAMING DECODER

--

-TO AUDIO DSP

I

H

K

6' HDMI CABLE

6' HDMI CABLE

J

6' HDMI CABLE

6' HDMI CABLE

INPUTS

--

--

--

--

HDMI

HDMI

HDMI

HDMI

HDMI 1

HDMI 2

HDMI 3

HDMI 4

6' HDMI CABLE

OUTPUTS

HDMI OUT HDMI --

TO NETWORK SWITCH

--

--

9PF

RJ45

RS232

LAN POWER PWR

MULTI-WINDOW PROCESSOR

--

-HDMI

INPUTS

HDMI IN

35' HDMI CABLE

35' HDMI CABLE

35' HDMI CABLE

35' VGA + AUDIO CABLE

-PWR POWER

19" PREVIEW MONITOR

--

INPUTS

HDMI HDMI IN

-PWR POWER

19" PREVIEW MONITOR

INPUTS

HDMI HDMI IN

PWR POWER

19" PREVIEW MONITOR

--

INPUTS

HDMI HDMI IN

-PWR POWER

19" PREVIEW MONITOR

WALL MOUNTED

**INSTALLED IN A WALL JB**

INPUTS OUTPUTS

RJ45 HDBASET

IN HDMI OUT

COM

HDMI

PHNX

RJ45 LAN

IR PHNX

PWR POWER

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - A)

6' HDMI CABLE

**INSTALLED IN A WALL JB**

RJ45

INPUTS

HDBASET

IN

OUTPUTS

HDMI OUT HDMI

COM PHNX

--

--

IR PHNX -RJ45

PWR

LAN

POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

6' HDMI CABLE

**INSTALLED IN A WALL JB**

INPUTS OUTPUTS

RJ45 HDBASET

IN

HDMI OUT HDMI

RJ45 LAN

COM

IR

PHNX

PHNX

PWR POWER

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - A)

6' HDMI CABLE

**INSTALLED IN A WALL JB**

INPUTS OUTPUTS

RJ45

HDBASET

IN

HDMI OUT

COM

HDMI

PHNX

--

--

IR PHNX -RJ45

PWR

LAN

POWER

HDBASET DIGITAL RECEIVER (TYPE - A)

6' HDMI CABLE

MULTI MODE FIBER EXTENDER 4.0MM LED TILE (01) 4.0MM LED TILE (72)

**CUSTOM VIDEO WALL BRACKET**

--

--

6' DVI-D MOLDED CABLE

--

--

55" LED MONITOR

(TYPE-B)

6' DVI-D MOLDED CABLE

6' DVI-D MOLDED CABLE

55" LED MONITOR

(TYPE-B)

4.0MM LED TILE (73) 4.0MM LED TILE (144)

DIRECT LED DISPLAY (TYPE - D) 16W X 9H TILE 4.0MM LED DISPLAY

SYSTEM WITH CUSTOM WALL MOUNT STRUCTURE FOR LED WALL

FRONT WALL LOCATION

55" LED MONITOR

(TYPE-B)

55" LED MONITOR

(TYPE-B)

--

--

6' DVI-D MOLDED CABLE

55" LED MONITOR

(TYPE-B) 6' DVI-D MOLDED CABLE

6' DVI-D MOLDED CABLE

55" LED MONITOR

(TYPE-B)

--

--

55" LED MONITOR

(TYPE-B)

55" LED MONITOR

(TYPE-B)

--

--

6' DVI-D MOLDED CABLE

55" LED MONITOR

(TYPE-B) 6' DVI-D MOLDED CABLE

6' DVI-D MOLDED CABLE

55" LED MONITOR

(TYPE-B)

--

--

55" LED MONITOR

(TYPE-B)

55" LED MONITOR

(TYPE-B)

--

--

6' DVI-D MOLDED CABLE

55" LED MONITOR

(TYPE-B)

6' DVI-D MOLDED CABLE

6' DVI-D MOLDED CABLE

55" LED MONITOR

(TYPE-B)

--

--

55" LED MONITOR

(TYPE-B)

55" LED MONITOR

(TYPE-B)

55" LED VIDEO WALL WITH SUPER NARROW BEZEL PANEL (TYPE - B)

4 X 4 VIDEO WALL LOCATION

REAR WALL LOCATION

MOBILE CART FOR CONFIDENCE MONITOR

65" LED BACK-LIT MONITOR

(CONFIDENCE MONITOR)

**INSTALLED IN A FLOOR JB**

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - B)

6' HDMI CABLE

**INSTALLED IN A FLOOR JB**

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - B)

**INSTALLED ABOVE CEILING**

6' HDMI CABLE

CUSTOM CONTROL CABLE

--

HDBASET DIGITAL RECEIVER (TYPE - A)

**INSTALLED IN A FLOOR JB**

--

--

--

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - B)

6' HDMI CABLE

L.H.S. AUDITORIUM

**INSTALLED IN A MOTORIZED LIFT

ASSEMBLY **

PROJECTOR

(TYPE-D)

MOBILE CART FOR CONFIDENCE MONITOR

40" LED BACK-LIT MONITOR

(CONFIDENCE MONITOR)

FLOOR LOCATION

CEILING LOCATION

FLOOR LOCATION

**INSTALLED ABOVE CEILING**

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - A)

6' HDMI CABLE

CUSTOM CONTROL CABLE

**INSTALLED IN A FLOOR JB**

--

--

--

HDBASET DIGITAL RECEIVER (TYPE - B)

6' HDMI CABLE

--

--

--

--

--

R.H.S. AUDITORIUM

**INSTALLED IN A MOTORIZED LIFT

ASSEMBLY **

PROJECTOR

(TYPE-D)

MOBILE CART FOR CONFIDENCE MONITOR

40" LED BACK-LIT MONITOR

(CONFIDENCE MONITOR)

CEILING LOCATION

FLOOR LOCATION

**INSTALLED ABOVE CEILING**

--

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

---

--

--

--

--

--

HDMI DISTRIBUTION AMPLIFIER

(TYPE-B)

IN ONE OF THE IP ROOM

MAIN AUDITORIUM

INTERPRETATION ROOMS

50' HDMI CABLE

19" PREVIEW MONITOR

IP ROOM # 01 TABLE/ DESK LOCATION

50' HDMI CABLE

50' HDMI CABLE

19" PREVIEW MONITOR

IP ROOM # 02 TABLE/ DESK LOCATION

HDMI

INPUTS

HDMI IN

PWR POWER

19" PREVIEW MONITOR

IP ROOM # 03 TABLE/ DESK LOCATION

**INSTALLED ABOVE CEILING**

--

HDBASET DIGITAL RECEIVER (TYPE - A)

3' HDMI CABLE

---

--

--

--

HDMI DISTRIBUTION AMPLIFIER

(TYPE-A)

IN ONE OF THE IP ROOM

FROM

AUDIO DSP

--

--

HDMI TO SDI SCALER

HD-SDI CABLE

3G HD−SDI MINI

OPTICAL TRANSMITTER

SECOND FLOOR CONTROL ROOM

OPTICAL FIBRE CABLE

50' HDMI CABLE

50' HDMI CABLE

19" PREVIEW MONITOR

IP ROOM # 04 TABLE/ DESK LOCATION

INPUTS

19" PREVIEW MONITOR

IP ROOM # 05 TABLE/ DESK LOCATION

3G HD−SDI MINI

OPTICAL RECEIVER

HD-SDI CABLE

OUTDOOR & AT OB-VAN LOCATION

Page 106 of 145

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S

DWG NO.:

AV07.A1

SHEET:

A3

SCALE:

1:1

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

SECOND FLOOR - VIDEO SCHEMATIC

SHEET TITLE :

SCHEMATIC DRAWING

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

5.

BY THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

MAIN AUDITORIUM

ACTIVE DIRECT BOX

ACTIVE DIRECT BOX

ACTIVE DIRECT BOX

ACTIVE DIRECT BOX

ACTIVE DIRECT BOX

ACTIVE DIRECT BOX

SUPERCARDIOID VOCAL MICROPHONE

SUPERCARDIOID VOCAL MICROPHONE

SUPERCARDIOID VOCAL MICROPHONE

SUPERCARDIOID VOCAL MICROPHONE

SUPERCARDIOID VOCAL MICROPHONE

SUPERCARDIOID VOCAL MICROPHONE

FOR STAGE SHOWS

GOOSENECK MICROPHONE

GOOSENECK MICROPHONE

GOOSENECK MICROPHONE

PODIUM LOCATION

3-XLR

32-CHANNEL STAGE-BOX

TO NETWORK

SWITCH

HEADPHONE (01)

PORTABLE CHAIRPERSON UNIT

HEADPHONE (02) PORTABLE CHAIRPERSON UNIT

HEADPHONE (03)

PORTABLE DELEGATE UNIT

HEADPHONE (04) PORTABLE DELEGATE UNIT

HEADPHONE (05) PORTABLE DELEGATE UNIT

HEADPHONE (06)

PORTABLE DELEGATE UNIT

HEADPHONE (07) PORTABLE DELEGATE UNIT

HEADPHONE (08)

PORTABLE DELEGATE UNIT

HEADPHONE (09) PORTABLE DELEGATE UNIT

HEADPHONE (10)

PORTABLE DELEGATE UNIT

HEADPHONE (11) PORTABLE DELEGATE UNIT

HEADPHONE (12)

PORTABLE DELEGATE UNIT

STAGE DESK LOCATION

HEADPHONE (01)

HEADPHONE (37)

HEADPHONE (02)

HEADPHONE (38)

DELEGATE UNIT

(01)

DELEGATE UNIT

(19)

HEADPHONE (39) HEADPHONE (40)

DELEGATE UNIT

(20)

HEADPHONE (75) HEADPHONE (76) PORTABLE DELEGATE UNIT

(38)

HEADPHONE (77)

HEADPHONE (115)

HEADPHONE (78)

HEADPHONE (116)

DELEGATE UNIT

(39)

DELEGATE UNIT

(58)

HEADPHONE (117)

HEADPHONE (155)

HEADPHONE (157) HEADPHONE (158)

HEADPHONE (195) HEADPHONE (196)

HEADPHONE (197)

HEADPHONE (235)

HEADPHONE (118)

HEADPHONE (156)

HEADPHONE (198)

HEADPHONE (236)

DELEGATE UNIT

(59)

DELEGATE UNIT

(78)

DELEGATE UNIT

(79)

DELEGATE UNIT

(98)

DELEGATE UNIT

(99)

DELEGATE UNIT

(118)

HEADPHONE (237)

HEADPHONE (275)

HEADPHONE (277) HEADPHONE (278)

HEADPHONE (315) HEADPHONE (316)

HEADPHONE (317) HEADPHONE (318)

HEADPHONE (355) HEADPHONE (356)

HEADPHONE (357)

HEADPHONE (399)

HEADPHONE (238)

HEADPHONE (276)

HEADPHONE (358)

HEADPHONE (400)

DELEGATE UNIT

(119)

DELEGATE UNIT

(138)

DELEGATE UNIT

(139)

DELEGATE UNIT

(158)

DELEGATE UNIT

(159)

DELEGATE UNIT

(178)

DELEGATE UNIT

(179)

DELEGATE UNIT

(200)

STAGE LOCATION

REPEATER

(CONFERENCING)

REPEATER

(CONFERENCING)

EXTENSION UNIT

(CONFERENCING)

CENTRAL CONTROL UNIT

WITH LICENSE FOR INTERPRETATION CHANNELS,

CONTROL SOFTWARE& VOTING SOFTWARE

(CONFERENCING)

INPUT

PHNX LINE -1

PHNX

PHNX

LINE -2

LINE -3

PHNX

PHNX

LINE -4

LINE -5

PHNX LINE -6

PHNX

PHNX

PHNX

LINE -7

LINE -8

LINE -9

OUTPUT

LINE OUT -1 PHNX

PHNX

LINE OUT -2

LINE OUT -3

LINE OUT -4

LINE OUT -5

LINE OUT -6

PHNX

PHNX

PHNX

PHNX

LINE OUT -7

LINE OUT -8

PHNX

PHNX

LINE OUT -9 PHNX

LINE OUT -10 PHNX

LINE OUT -11 PHNX

LINK RJ-45

RJ45 LINK

ETHERNET RJ-45

RS-232

POWER

9PF

PWR

DIGITAL SIGNAL PROCESSOR (TYPE C)

REPEATER

(CONFERENCING)

HEADPHONE (01)

HEADPHONE (02)

INTERPRETER SET (01)

INTERPRETER SET (02)

HEADPHONE (03) INTERPRETER SET (03)

HEADPHONE (04) INTERPRETER SET (04)

HEADPHONE (05) INTERPRETER SET (05)

HEADPHONE (01) INTERPRETER SET (01)

HEADPHONE (02) INTERPRETER SET (02)

HEADPHONE (03)

HEADPHONE (04)

INTERPRETER SET (03)

INTERPRETER SET (04)

HEADPHONE (05) INTERPRETER SET (05)

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

ACTIVE DIRECTIONAL ANTENNA

470-900 MHz

--

ACTIVE DIRECTIONAL ANTENNA

470-900 MHz

--

100’ ANTENNA CABLE (TYPE - B)

100’ ANTENNA CABLE (TYPE - B)

AUDIENCE AREA

INTERPRETER ROOM # 01

INTERPRETER ROOM # 02

INTERPRETER ROOM # 03

INTERPRETER ROOM # 04

INTERPRETER ROOM # 05

INTERPRETER ROOM # 01

INTERPRETER ROOM # 02

INTERPRETER ROOM # 03

INTERPRETER ROOM # 04

INTERPRETER ROOM # 05

ACTIVE DIRECTIONAL ANTENNA

470-900 MHz

--

--

50’ ANTENNA CABLE (TYPE - B)

100’ ANTENNA CABLE (TYPE - B)

UHF IN-LINE AMPLIFIER

UHF IN-LINE AMPLIFIER

ACTIVE ANTENNA SPLITTER

ACTIVE ANTENNA SPLITTER

HEADPHONE (01) INTERPRETER SET (01)

HEADPHONE (02) INTERPRETER SET (02)

HEADPHONE (03) INTERPRETER SET (03)

HEADPHONE (04) INTERPRETER SET (04)

HEADPHONE (05) INTERPRETER SET (05)

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

UHF WIRELESS HANDHELD TRANSMITTER

WITH MICROPHONE CAPSULE

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

UHF WIRELESS BODYPACK TRANSMITTER

WITH LAPEL MICROPHONE

INTERPRETER ROOM # 01

INTERPRETER ROOM # 02

INTERPRETER ROOM # 03

INTERPRETER ROOM # 04

INTERPRETER ROOM # 05

ACTIVE DIRECTIONAL ANTENNA

470-900 MHz

--

--

50’ ANTENNA CABLE (TYPE - B)

100’ ANTENNA CABLE (TYPE - B)

ACTIVE ANTENNA SPLITTER

ACTIVE ANTENNA SPLITTER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

LEFT AUDITORIUM

CAT 5 CABLE

RJ45

RJ45

RJ45

RJ45

A

B

C

D

OUT A XLR

OUT B XLR

OUT C XLR

OUT D XLR

OUT E XLR

OUT F XLR

OUT G XLR

OUT H XLR

CA00

CA00

CA00

CA00

CA00

ETHERNET RJ-45

POWER PWR

CENTRAL CONTROL UNIT

WITH LICENSE FOR INTERPRETATION CHANNELS

(CONFERENCING)

XLR TO RCA PHONO CABLE

XLR TO RCA PHONO CABLE

XLR TO RCA PHONO CABLE

XLR TO RCA PHONO CABLE

XLR TO RCA PHONO CABLE

FROM AUDIO DSP

CA00

--

--

--

CA00

CA00

CA00

CA00

--

--

--

INPUT

RCA

RCA

RCA

RCA

RCA 1

RCA

RCA 3

2

5

4

6

7

RCA 8

OUTPUT

OUT A BNC

OUT B

OUT C

BNC

BNC

OUT D BNC

OUT E BNC

OUT F BNC

XLR L

XLR R

BNC

ETHERNET

POWER

DIGITAL IR-TRANSMITTER

(CONFERENCING)

RJ-45

PWR

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

DIVERSITY RECEIVER

INPUT

3-XLR MIC/LINE -1

3-XLR

3-XLR

MIC/LINE -2

MIC/LINE -3

3-XLR

3-XLR

3-XLR

3-XLR

MIC/LINE -4

MIC/LINE -5

MIC/LINE -6

MIC/LINE -7

3-XLR

3-XLR

3-XLR

3-XLR

3-XLR

3-XLR

3-XLR

3-XLR

MIC/LINE -8

MIC/LINE -9

MIC/LINE -10

MIC/LINE -11

MIC/LINE -12

MIC/LINE -13

MIC/LINE -14

MIC/LINE -15

3-XLR MIC/LINE -16

PHONO LINE -01

PHONO

PHONO

PHONO

LINE -01

LINE -01

LINE -01

3-XLR AES IN

MIDI MIDI IN

AES OUT

MIDI OUT

3-XLR

MIDI

DATA

POWER

RJ45

PWR

16-CHANNEL MIXING CONSOLE

OUTPUT

LINE-1 3-XLR

LINE-2 3-XLR

LINE-3 3-XLR

LINE-4 3-XLR

LINE-5 3-XLR

LINE-6 3-XLR

LINE-7 3-XLR

LINE-8 3-XLR

LINE-9 3-XLR

LINE-10 3-XLR

LINE-11 3-XLR

LINE-12 3-XLR

LINE-13 3-XLR

LINE-14 3-XLR

LINE-15 3-XLR

LINE-16 3-XLR

STEREO HEADPHONE (01)

REAR CONTROL ROOM

INPUTS

XLR INPUT

PWR POWER

ACTIVE MONITOR

LOUDSPEAKER

CAT 5 CABLE

CF00

CF00

CF00

CF00

RJ45

RJ45

RJ45

RJ45

A

B

C

D

INPUT OUTPUT

OUT A

OUT B

XLR

XLR

OUT C

XLR

OUT D XLR

OUT E XLR

OUT F XLR

OUT G XLR

OUT H XLR

ETHERNET RJ-45

PWR

POWER

CENTRAL CONTROL UNIT

WITH LICENSE FOR INTERPRETATION CHANNELS

(CONFERENCING)

XLR TO RCA PHONO CABLE

XLR TO RCA PHONO CABLE

XLR TO RCA PHONO CABLE

XLR TO RCA PHONO CABLE

XLR TO RCA PHONO CABLE

FROM AUDIO DSP

INPUT OUTPUT

RCA

RCA

1

2

RCA

RCA

3

4

RCA

RCA

5

6

RCA 7

RCA 8

XLR L

XLR

BNC

R

HF INPUT

OUT A

OUT B

OUT C

BNC

BNC

BNC

OUT D BNC

OUT E BNC

OUT F BNC

ETHERNET RJ-45

PWR

POWER

DIGITAL IR-TRANSMITTER

(CONFERENCING)

RGHT AUDITORIUM

HEADPHONE (01) WALL PLATE FOR MONITORING

(01)

HEADPHONE (02) WALL PLATE FOR MONITORING

(02)

HEADPHONE (03) WALL PLATE FOR MONITORING

(03)

HEADPHONE (04) WALL PLATE FOR MONITORING

(04)

INPUT

3-XLR

3-XLR

3-XLR

3-XLR

MIC/LINE -13

MIC/LINE -14

MIC/LINE -15

MIC/LINE -16

3-XLR

3-XLR

3-XLR

3-XLR

MIC/LINE -17

MIC/LINE -18

MIC/LINE -19

MIC/LINE -20

3-XLR

3-XLR

MIC/LINE -21

MIC/LINE -22

3-XLR

3-XLR

MIC/LINE -23

MIC/LINE -24

3-XLR MIC/LINE -25

3-XLR

3-XLR

MIC/LINE -26

MIC/LINE -27

3-XLR

3-XLR

MIC/LINE -28

MIC/LINE -29

3-XLR MIC/LINE -30

3-XLR

3-XLR

MIC/LINE -31

MIC/LINE -32

PHONO LINE -01

PHONO LINE -02

PHONO

PHONO

LINE -03

LINE -04

3-XLR

MIDI

AES IN

MIDI IN

AES OUT

MIDI OUT

3-XLR

MIDI

DATA

POWER

RJ45

PWR

32-CHANNEL MIXING CONSOLE

OUTPUT

LINE-1 3-XLR

LINE-2 3-XLR

LINE-3 3-XLR

LINE-4 3-XLR

LINE-5 3-XLR

LINE-6 3-XLR

LINE-7 3-XLR

LINE-8 3-XLR

LINE-9 3-XLR

LINE-10

LINE-11

LINE-12

3-XLR

3-XLR

3-XLR

LINE-13

LINE-14

LINE-15

LINE-16

3-XLR

3-XLR

3-XLR

3-XLR

TO NETWORK

SWITCH

INPUTS

XLR INPUT

PWR

ACTIVE MONITOR

LOUDSPEAKER

STEREO HEADPHONE (01)

CONSOLE AREA

16-CHANNEL MIXING CONSOLE

STEREO HEADPHONE (01)

REAR CONTROL ROOM

ACTIVE MONITOR

LOUDSPEAKER

FROM 32X32 MATRIX SWITCHER

FROM 32X32 MATRIX SWITCHER

FROM 32X32 MATRIX SWITCHER

FROM VC CODEC

FROM CAPTURE RECORDER

FROM PROD. SWITCHER

GOOSENECK MICROPHONE

INPUT

PHNX LINE -1

PHNX

PHNX

LINE -2

LINE -3

PHNX

PHNX

LINE -4

LINE -5

PHNX LINE -6

PHNX MIC/LINE -7

OUTPUT

LINE OUT -1

LINE OUT -2

PHNX

PHNX

LINE OUT -3

LINE OUT -4

LINE OUT -5

LINE OUT -6

PHNX

PHNX

PHNX

PHNX

LINE OUT -7

LINE OUT -8

PHNX

PHNX

LINE OUT -9 PHNX

LINE OUT -10 PHNX

LINK RJ-45

--

--

--

--

--

--

--

--

--

--

--

RJ45 LINK

ETHERNET

RJ-45

RS-232

POWER

9PF

PWR

DIGITAL SIGNAL PROCESSOR (TYPE C)

--

--

--

TO VC CODEC

TO RECORDER

TO HDMI TO 3G-SDI SCALAR

TO PRODUCTION SWITCHER

TO MAIN AUDITORIUM STAGE MONITOR AMPLIFIER

(TYPE - E)

TO MAIN AUDITORIUM STAGE MONITOR AMPLIFIER

(TYPE - E)

LINK

RJ-45

RJ45 LINK

DIGITAL SIGNAL PROCESSOR (TYPE C)

TO DIGITAL IR-TRANSMITTER

LINK RJ-45

RJ45 LINK

DIGITAL SIGNAL PROCESSOR (TYPE C)

TO DIGITAL IR-TRANSMITTER

--

--

--

--

PHNX 1

PHNX 2

PHNX

PHNX

3

4

INPUT OUTPUT

1 PHNX

2 PHNX

3 PHNX

4 PHNX

POWER PWR

--

--

POWER AMPLIFIER (TYPE-B)

--

--

PHNX 1

INPUT

PHNX 2

OUTPUT

1 PHNX

2 PHNX

--

--

3 PHNX

4 PHNX

--

--

--

--

PHNX 3

PHNX 4

POWER PWR

POWER AMPLIFIER (TYPE-B)

--

--

--

--

--

PHNX 1

INPUT

PHNX 2

PHNX 3

PHNX 4

OUTPUT

1 PHNX

2 PHNX

3 PHNX

4 PHNX

--

--

--

--

POWER PWR

POWER AMPLIFIER (TYPE-B)

PHNX 1

INPUT OUTPUT

1 PHNX

2 PHNX

2 PHNX PHNX 2

PHNX 1 3 PHNX

PHNX 2

POWER

POWER AMPLIFIER (TYPE-B)

PWR

PHNX

PHNX

1

2

INPUT OUTPUT

1 PHNX

2 PHNX

POWER PWR

POWER AMPLIFIER (TYPE-C)

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S.

DWG NO.:

AV08.A1

SHEET:

A3

SCALE:

1:1

STAGE MONITOR

LOUDSPEAKER-L

(TYPE-A)

STAGE MONITOR

LOUDSPEAKER-L

(TYPE-A)

STAGE MONITOR

(TYPE-A)

STAGE MONITOR

LOUDSPEAKER-R

(TYPE-A)

FOH LOUDSPEAKER-L

(TYPE-A)

MID & HIGH FILL

LOUDSPEAKER (TYPE - B)

FOH LOUDSPEAKER-C

(TYPE-A)

MID & HIGH FILL

LOUDSPEAKER (TYPE - B)

FOH LOUDSPEAKER-R

(TYPE-A)

MID & HIGH FILL

LOUDSPEAKER (TYPE - B)

SUBWOOFER

(TYPE-A)

SUBWOOFER

(TYPE-A)

PROJECT MANAGEMENT CONSULTANTS

CEILING LOCATION

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

STAGE LOCATION

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

INDOOR MONITOR

LOUDSPEAKER

(TYPE-C)

INDOOR MONITOR

LOUDSPEAKER

(TYPE-C)

INDOOR MONITOR

(TYPE-C)

INDOOR MONITOR

LOUDSPEAKER

(TYPE-C)

GREEN ROOMS

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

50M RG59 CABLE

50M RG59 CABLE

**INSTALLED ON A WALL

MOUNT BRACKET**

INFRARED DIGITAL RADIATOR

**INSTALLED ON A WALL

MOUNT BRACKET**

INFRARED DIGITAL RADIATOR

WALL LOCATION

STEREO HEADPHONE (01)

8-CHANNEL INFRARED

DIGITAL RECEIVER

WITH RECHARGEABLE BATTERY

(01)

STEREO HEADPHONE (200)

8-CHANNEL INFRARED

DIGITAL RECEIVER

WITH RECHARGEABLE BATTERY

(200)

AUDIENCE AREA

D

POWER AMPLIFIER (TYPE-B)

POWER AMPLIFIER (TYPE-B)

A

F

E

POWER AMPLIFIER (TYPE-B)

C

B

F

E

D

POWER AMPLIFIER (TYPE-B)

SECOND FLOOR CONTROL ROOM

A

B

C

FOH LOUDSPEAKER-L

(TYPE-A)

FOH LOUDSPEAKER-R

(TYPE-A)

SUBWOOFER

(TYPE-B)

STAGE MONITOR

LOUDSPEAKER-L

(TYPE-A)

STAGE MONITOR

LOUDSPEAKER-R

(TYPE-A)

50M RG59 CABLE

50M RG59 CABLE

**INSTALLED ON A WALL

MOUNT BRACKET**

INFRARED DIGITAL RADIATOR

**INSTALLED ON A WALL

MOUNT BRACKET**

INFRARED DIGITAL RADIATOR

WALL LOCATION

STEREO HEADPHONE (01)

8-CHANNEL INFRARED

DIGITAL RECEIVER

WITH RECHARGEABLE BATTERY

(01)

FOH LOUDSPEAKER-L

(TYPE-A)

FOH LOUDSPEAKER-R

(TYPE-A)

SUBWOOFER

(TYPE-B)

LOUDSPEAKER-L

(TYPE-A)

STAGE MONITOR

LOUDSPEAKER-R

(TYPE-A)

DRAWING TITLE:

SECOND FLOOR - AUDIO SCHEMATIC

CEILING LOCATION

FLOOR LOCATION

SHEET TITLE :

SCHEMATIC DRAWING

STAGE LOCATION

STEREO HEADPHONE (200)

8-CHANNEL INFRARED

DIGITAL RECEIVER

WITH RECHARGEABLE BATTERY

(200)

AUDIENCE AREA

CEILING LOCATION

FLOOR LOCATION

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

5.

BY THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

STAGE LOCATION

Page 107 of 145

RS-232

COM-1

COM-2

COM-3

COM-4

COM-5

COM-6

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

IR-SERIAL OUTPUT

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

3

S

G

4

S

G

1

S

G

2

S

G

5

S

G

6

S

G

7

S

G

8

S

G

RELAYS

5

6

3

4

7

8

1

2

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

9PF RS-232

VIDEO CONFERENCING CODEC

9PF RS-232

VIDEO PROCESSING SYSTEM

9PF RS-232

LIGHTING CONTROL (RIGHT AUDITORIUM)

9PF RS-232

9PF RS-232

9PF RS-232

CAMERA CONSOLE UNIT

LIGHTING CONTROL (MAIN AUDITORIUM)

LIGHTING CONTROL (RIGHT AUDITORIUM)

MOTORIZED SCREEN # 1 (UP)

MOTORIZED LIFT ASSEMBLY # 1 (UP)

MOTORIZED SCREEN # 2 (UP)

MOTORIZED LIFT ASSEMBLY # 2 (UP)

POE NETWORK

SWITCH

LEFT AUDITORIUM

MOTORIZED SCREEN # 1 (DOWN)

MOTORIZED LIFT ASSEMBLY # 1 (DOWN)

MOTORIZED SCREEN # 2 (DOWN)

MOTORIZED LIFT ASSEMBLY # 2 (DOWN)

RIGHT AUDITORIUM

I/O PORTS

1

2

3

4

7

8

5

6

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

PHNX

LAN A RJ45

CONTROL PROCESSOR

(CONFIG - A)

FROM LAN BY OTHERS

(CONTROL 32X32 SWITCHER OVER ETHERNET)

FROM NETWORK SWITCH

POE NETWORK

SWITCH

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - B)

INPUTS

--

RJ45 CAMERA CONTROL

OUTPUTS

CONTROL

PORT

9PF --

TO CONTROL

PROCESSOR (OPTIONAL)

POWER PWR --

OPERATOR BASED CAMERA

CONTROLLER (TYPE - A)

Page 108 of 145

MASTER CONTROL ROOM RACK

FOR TENDER RELEASE

NO. DATE DESCRIPTION.

CHKD

BY.

00 14.04.17

FOR TENDER

RELEASE

M.S.

TO AUDIO DSP

CONTROL PORTS

DWG NO.:

AV09.A1

SHEET:

A3

SCALE:

1:1

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

MAIN AUDITORIUM (PODIUM LOCATION)

PROJECT MANAGEMENT CONSULTANTS

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

LEFT AUDITORIUM (PODIUM LOCATION)

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

TABLE TOP WIRED TOUCH

PANEL WITH MOUNTING KIT AND

ACCESSORIES (TYPE - A)

RIGHT AUDITORIUM (PODIUM LOCATION)

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

--

--

INPUTS

PHNX CONTROL

IN

POWER PWR

WALL MOUNT

VOLUME CONTROLLER

(TYPE-A)

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

TO AUDIO DSP

CONTROL PORTS

--

--

INPUTS

PHNX CONTROL

IN

POWER PWR

WALL MOUNT

VOLUME CONTROLLER

(TYPE-A)

PROJECT:

TO AUDIO DSP

CONTROL PORTS

--

--

PWR

INPUTS

PHNX CONTROL

IN

POWER

WALL MOUNT

VOLUME CONTROLLER

(TYPE-A)

CLIENT:

TO AUDIO DSP

CONTROL PORTS

--

--

INPUTS

PHNX CONTROL

IN

POWER PWR

WALL MOUNT

VOLUME CONTROLLER

(TYPE-A)

GREEN ROOMS WALL LOCATION

DRAWING TITLE:

SECOND FLOOR - CONTROL SCHEMATIC

SHEET TITLE :

SCHEMATIC DRAWING

CONFIDENTIALITY

STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3.

DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE

BY THE CONTRACTOR OR ANY OTHER AGENCIES

5.

REFERRING TO THIS DRAWING.

DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

NOTE:

PROVIDE ONLY A BRIEF IDEA ABOUT THE

PROJECT. IN CASE OF ANY QUANTITATIVE

DISCREPANCY BETWEEN THE SCHEMATIC AND THE

BOQ, THE BOQ SHALL PREVAIL.

IG

P

P

IG

J

#

S

AFC

J

#/F

A/V DRAWING ABBREVIATIONS:

LVC

PS(#)

LVC

MS(#)

TV

P

IG

FB

1

A/V DRAWING ABBREVIATIONS:

S

PS

PB

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

SHEET TITLE :

AV NOTES & GUIDELINES

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 109 of 145

ML

ML

ML

ML

ML

V

GD1

GD1

PLS REF.

STAICASE

DET.DWG

D2

TD

FD2

V

UP

+100.10 LVL

STAICASE

DET.DWG

FD2

D6

D1

D6

D1

TD

D1

D4

D4

D4

D4

+101.30 F.F.L

+101.30 F.F.L

STRUCTURAL GLAZING

GLAZED WINDOW

D2

+101.30 F.F.L

D1

+101.30 F.F.L

- 01 - 02 - 03

DN

+102.80 LVL

- 04 - 05

CONTROL

ROOM

PLS REF.

STAICASE

DET.DWG

D1

D1

GD1

GD1

GD1

GD1

GD1 GD1

GD1

+101.30 F.F.L

GD1

GLASS

WORK

FD2

D1

V

GD1

GD1

TD

FD2

+101.30 F.F.L

+101.30 F.F.L

FD1

PLS REF.

STAICASE

DET.DWG

TD

PLS REF.

STAICASE

DET.DWG

FD1

GD1

V

ML ML

+101.30 F.F.L

D1

D1

D2

D1

D1

D1

- 01

- 02

+101.30 F.F.L

D1

- 03 - 04

+102.80 LVL

- 05

DN

CONTROL

ROOM

D1

D2

DN

D2

+101.30 F.F.L

FD2

D1

+101.30 F.F.L

PLS REF.

STAICASE

DET.DWG

D3

D3

D3

D3

ML

PLS REF.

STAICASE

DET.DWG

+101.30 F.F.L

ML

DN

ML

ML

6.5 M WIDE LANE

RAMP UP

+100.10 LVL

ML

ML

RAMP UP

+100.10 LVL

UP

+100.10 LVL

ML

+100.10 LVL

Page 110 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV01.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

GROUND FLOOR, CLASSIFICATION OF ROOMS

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

D6

GD1

GD1

GLASS

WORK

GD1

7

1

F.F

2

GD1

+2134 MM

A.F.F

J

1

2

3

2

A.F.C

+101.30 F.F.L

A.F.C

2

4

1

A.F.C

1 1

J

4

+2133.6 MM

A.F.F

J

+1583 MM

A.F.F

1

F.F

1

7

5

6

J J

+150 MM

A.F.F

+1219 MM

A.F.F

2

A.F.C

3

1

J

2

7

1

F.F

2

+2134 MM

A.F.F

D1

D1

REVISION

HISTORY:

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN):

EXHIBITION HALL

1 AT 198" PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 124.7 KG

SIZE - 105" H X 168" W (2667MM H X 4267.2MM W)]

2 AT EACH 165" PROJECTION SCREEN LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUITSTUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 68.04 KG

SIZE - 87 1/2" H X 140" W (2222.5MM H X 3556 MM W)]

3 AT PROJECTOR LOCATION (CEILING) INSTALLED IN A LIFT PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 1500 WATTS

WEIGHT - 27 KG

SIZE - 561 X 500 X 259 MM (L X W X H)]

4

AT EACH CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1"Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

5

AT WALL-PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF WALL-PLATE:

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

6

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1]1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM]

7

AT FLOOR LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF FLOOR PLATE:

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

** LEAVE [4] 1" Ø CONDUITS FROM CONTROL ROOM TO ACCESSIBLE CEILING FOR CEILING SPEAKERS &

[4] 1"Ø CONDUITS FOR MICROPHONE ANTENNAS **

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV02.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - EXHIBITION HALL

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 111 of 145

1

150MM

1583MM

350MM

4

4500MM

350MM

6

5

1219MM

198" DIAGONAL

SCREEN

2133,6MM

150MM

HALL &

SCREEN

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN):

EXHIBITION HALL

1

AT 198" PROJECTION SCREEN LOCATION PROVIDE:

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 124.7 KG

SIZE - 105" H X 168" W (2667MM H X 4267.2MM W)]

4

AT EACH CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1"Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

5

AT WALL-PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF WALL-PLATE:

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

6

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1]1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM]

Page 112 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV03.A1

SHEET:

A3

SCALE:

1:1

AV & ACOUSTICS

CONSULTANT

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT

CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION - EXHIBITION HALL

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

2

1

16000MM

150MM

2222MM

2667MM

4500MM

1583MM

150MM

1219MM

5

6

2182MM

AV ELECTRICAL NOTES (SECTIONAL PLAN):

EXHIBITION HALL

1

AT 198" PROJECTION SCREEN LOCATION PROVIDE:

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 124.7 KG

SIZE - 105" H X 168" W (2667MM H X 4267.2MM W)]

2

AT EACH 165" PROJECTION SCREEN LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUITSTUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 68.04 KG

SIZE - 87 1/2" H X 140" W (2222.5MM H X 3556 MM W)]

3

AT PROJECTOR LOCATION (CEILING) INSTALLED IN A LIFT PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 1500 WATTS

WEIGHT - 27 KG

SIZE - 561 X 500 X 259 MM (L X W X H)]

5

AT WALL-PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF WALL-PLATE:

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

6

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1]1" Ø CONDUIT FROM CEILING AND LAID UNTIL THE CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM]

Page 113 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV04.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

SECTION - EXHIBITION HALL

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

REVISION

HISTORY:

AV ELECRICAL NOTES (ELECTRICAL FLOOR PLAN):

TRAINING ROOM # 01

1

AT EACH 189" PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 90.3 KG

SIZE - 100" H x 160" W (2540MM H X 4064MM W)]

4

2

AT EACH PROJECTOR (AT CEILING INSTALLED IN A PROJECTOR LIFT) LOCATION PROVIDE:

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA / LAN POINTS FOR A/V EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1"Ø CONDUIT FROM ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 1500 WATTS

WEIGHT - 27KG

SIZE - 561 X 500 X259 MM (L X W X H)]

3

AT FRONT WALL-MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X J- BOX W / [1] 1" Ø CONDUIT STUBBED UPTO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF FRONT WALL-MOUNTED CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X179.3 MM (H X W X D)]

AT CEILING-MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SOCKET;

01 X DATA / LAN POINT FOR A/V EQUIPMENT ONLY;

01 X J- BOX W / [1] 1" Ø CONDUIT STUBBED UPTO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF CEILING-MOUNTED CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X179.3 MM (H X W X D)]

5

AT WALL-MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SOCKET;

01 X J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE :

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

6

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE-GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM (H X W X D)]

** LEAVE [2] 1"Ø CONDUITS FOR CEILING SPEAKERS FROM CONTROL ROOM TO ACCESSIBLE CEILING**

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV05.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - TRAINING ROOM # 01

CONFIDENTIALITY STATEMENT :

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 114 of 145

1 3 1

195,6MM

189" DIAGONAL

SCREEN

2540MM

6

4000MM

1219,2MM

350MM

2134MM

150MM

5

4064MM

914,4MM

5

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN) :

TRAINING ROOM # 01

1

AT EACH 189" PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 90.3 KG

SIZE - 100" H x 160" W (2540MM H X 4064MM W)]

3

AT FRONT WALL-MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X J- BOX W / [1] 1" Ø CONDUIT STUBBED UPTO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF FRONT WALL-MOUNTED CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X179.3 MM (H X W X D)]

AT WALL-MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SOCKET;

01 X J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE :

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

6

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE-GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM (H X W X D)]

Page 115 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV06.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION - TRAINING ROOM # 01

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

1

195,6MM

3

2540MM

6

2134MM

1219,2MM

5

914,4MM

150MM 300MM

2

1 2 3 4 5

6

7

8

9

10

11

12

5

AV ELECRICAL NOTES (SECTIONAL PLAN):

TRAINING ROOM # 01

1

AT EACH 189" PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 90.3 KG

SIZE - 100" H x 160" W (2540MM H X 4064MM W)]

2

AT EACH PROJECTOR (AT CEILING INSTALLED IN A PROJECTOR LIFT) LOCATION PROVIDE:

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA / LAN POINTS FOR A/V EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1"Ø CONDUIT FROM ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 1500 WATTS

WEIGHT - 27KG

SIZE - 561 X 500 X259 MM (L X W X H)]

3

AT FRONT WALL-MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X J- BOX W / [1] 1" Ø CONDUIT STUBBED UPTO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF FRONT WALL-MOUNTED CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X179.3 MM (H X W X D)]

6

AT WALL-MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SOCKET;

01 X J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE :

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE-GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM (H X W X D)]

Page 116 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV07.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

SECTION - TRAINING ROOM # 01

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

D1

+914.4 MM

A.F.F

1

+150 MM

A.F.F

+914.4 MM

A.F.F

1

5

+2134MM

A.F.F

2

2

2

A.F.C

4

2

D1

D2

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

AV ELECRICAL NOTES (ELECTRICAL FLOOR PLAN):

TRAINING ROOM # 02

1

AT EACH 189" PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 90.3 KG

SIZE - 100" H x 160" W (2540MM H X 4064MM W)]

4

2

AT EACH PROJECTOR (AT CEILING INSTALLED IN A PROJECTOR LIFT) LOCATION PROVIDE:

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA / LAN POINTS FOR A/V EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1"Ø CONDUIT FROM ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 1500 WATTS

WEIGHT - 27KG

SIZE - 561 X 500 X259 MM (L X W X H)]

3

AT FRONT WALL-MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X J- BOX W / [1] 1" Ø CONDUIT STUBBED UPTO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF FRONT WALL-MOUNTED CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X179.3 MM (H X W X D)]

AT CEILING-MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SOCKET;

01 X DATA / LAN POINT FOR A/V EQUIPMENT ONLY;

01 X J- BOX W / [1] 1" Ø CONDUIT STUBBED UPTO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF CEILING-MOUNTED CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X179.3 MM (H X W X D)]

5

AT WALL-MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SOCKET;

01 X J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE :

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

6

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE-GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM (H X W X D)]

** LEAVE [2] 1"Ø CONDUITS FOR CEILING SPEAKERS FROM CONTROL ROOM TO ACCESSIBLE CEILING**

DWG NO.:

AV08.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - TRAINING ROOM # 02

CONFIDENTIALITY STATEMENT :

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 117 of 145

1 3 1

195,6MM

189" DIAGONAL

SCREEN

2540MM

6

4000MM

1219,2MM

350MM

2134MM

5

4064MM

914,4MM

5

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN) :

TRAINING ROOM # 02

1

AT EACH 189" PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 90.3 KG

SIZE - 100" H x 160" W (2540MM H X 4064MM W)]

3

AT FRONT WALL-MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X J- BOX W / [1] 1" Ø CONDUIT STUBBED UPTO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF FRONT WALL-MOUNTED CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X179.3 MM (H X W X D)]

AT WALL-MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SOCKET;

01 X J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE :

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

6

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE-GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM (H X W X D)]

Page 118 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV09.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION - TRAINING ROOM # 02

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

2

1

3

2540MM

4000MM

914,4MM

6

2134MM

5

1219,2MM

150MM

5

AV ELECRICAL NOTES (SECTIONAL PLAN):

TRAINING ROOM # 01

1

AT EACH 189" PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 90.3 KG

SIZE - 100" H x 160" W (2540MM H X 4064MM W)]

2

AT EACH PROJECTOR (AT CEILING INSTALLED IN A PROJECTOR LIFT) LOCATION PROVIDE:

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA / LAN POINTS FOR A/V EQUIPMENT ONLY;

01 X SINGLE GANG J- BOX W / [1] 1"Ø CONDUIT FROM ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 1500 WATTS

WEIGHT - 27KG

SIZE - 561 X 500 X259 MM (L X W X H)]

3

AT FRONT WALL-MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SOCKET;

01 X DATA / LAN POINT FOR AV EQUIPMENT ONLY;

01 X J- BOX W / [1] 1" Ø CONDUIT STUBBED UPTO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF FRONT WALL-MOUNTED CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X179.3 MM (H X W X D)]

6

AT WALL-MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SOCKET;

01 X J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE :

LOAD - 11 W

WEIGHT - 403 GRAMS

SIZE - 105 X 89 X 69 MM (H X W X D)]

AT WALL-MOUNTED TOUCH-PANEL LOCATION PROVIDE :

01 X SINGLE-GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF WALL-MOUNTED PLATE:

LOAD - 13 W

WEIGHT - 400 GRAMS

SIZE - 121 X 193 X 52 MM (H X W X D)]

Page 119 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV0A.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

SECTION - TRAINING ROOM # 02

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

AV RACK

CONTROL

ROOM

2

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN):

CONTROL ROOM

1

AT A/V RACK LOCATION PROVIDED:

04 X 16 AMP UPS POWER SOCKETS;

04 X DATA / LAN POINTS FOR A/V EQUIPMENT ONLY;

2

AT TABLE LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA / LAN POINTS FOR A/V EQUIPMENT ONLY;

01 X SINGLE GANG J- [email protected] FLOOR LOCATION W / [1] 1"Ø CONDUIT TO A/V RACK.

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV0B.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM GROUND FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - CONTROL ROOM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 120 of 145

(Male)

D4

MD

+106.85 LVL

W - 2000MM

T = 300MM

R = 150MM

D1

+106.85 LVL

TD

RCC WALL

+106.85 LVL

D4 1

7

+107.95 LVL

+106.85 LVL

D1

UP

DN

LIFT

+106.85 LVL

+107.95 LVL

+106.85 LVL

+106.85 LVL

UP

D3

D3

D3

D3

+106.85 LVL

(Below)

+106.85 LVL

+107.95 LVL

D3

+106.85 LVL

D1

D1

D1

+106.85 LVL

D1

D4

TD

+106.85 LVL

D1

D1

LOUNGE

+106.85 LVL

+106.85 LVL

FD2

D1

D3

D3

D3

D3

Page 121 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV10.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

CLASSIFICATION OF ROOMS

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

+1250MM

A.F.F

2

4

1

4

CONFERENCE

1

4

ROOM

1

4

4

1

1

1

+1200MM

A.F.F

1

1

J

+1100MM

A.F.F

3

D1

D1

2

+1250MM

A.F.F

1

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN):

LARGE CONFERENCE ROOM

AT EACH 98" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

01 x 6/16 AMP UPS POWER SUPPLY SOCKET

W / [1] 1" Ø CONDUIT STUBBED UP TO MONITOR AND LAID UNTIL MASTER

CONTROL ROOM.

2

AT EACH 75" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

02 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

02 x DATA / LAN POINT ;

01 x 2 GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

DWG NO.:

AV11.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

3

AT EACH WALL - MOUNTED CAMERA LOCATION PROVIDE:

02 x 6/16 AMP UPS POWER SUPPLY SOCKET;

01 x DATA / LAN POINT;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

4 AT TABLE CABLE CUBBY LOCATION PROVIDE :

02 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

02 x DATA / LAN POINT ;

01 x 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM.

** LEAVE [2] 1"Ø CONDUITS FROM MASTER CONTROL ROOM TO CEILING FOR CEILING SPEAKERS **

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM FIRST FLOOR

SHEET TITLE :

FLOOR PLAN - LARGE CONF. ROOM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 122 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

1249.8MM

1

2194.2MM

3600MM

DWG NO.:

AV12.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

1200MM

3

1100MM

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

1

3

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN):

LARGE CONFERENCE ROOM

AT EACH 98" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

01 x 6/16 AMP UPS POWER SUPPLY SOCKET

W / [1] 1" Ø CONDUIT STUBBED UP TO MONITOR AND LAID UNTIL MASTER

CONTROL ROOM.

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

AT EACH WALL - MOUNTED CAMERA LOCATION PROVIDE:

02 x 6/16 AMP UPS POWER SUPPLY SOCKET;

01 x DATA / LAN POINT;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER

CONTROL ROOM.

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM FIRST FLOOR

SHEET TITLE :

FRONT ELEVATION - LARGE CONF. ROOM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 123 of 145

2

1

2194.2MM

3

1200MM

1100MM

959.5MM

1676.2MM

1524MM

3600MM

AV ELECTRICAL NOTES (SECTIONAL PLAN):

LARGE CONFERENCE ROOM

1

AT EACH 98" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

01 x 6/16 AMP UPS POWER SUPPLY SOCKET

W / [1] 1" Ø CONDUIT STUBBED UP TO MONITOR AND LAID UNTIL MASTER

CONTROL ROOM.

2

AT EACH 75" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

02 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

02 x DATA / LAN POINT ;

01 x 2 GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

3

AT EACH WALL - MOUNTED CAMERA LOCATION PROVIDE:

02 x 6/16 AMP UPS POWER SUPPLY SOCKET;

01 x DATA / LAN POINT;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV13.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM FIRST FLOOR

SHEET TITLE :

SECTION - LARGE CONF. ROOM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 124 of 145

2

+1100MM

A.F.F

3

1

1

J

+1250MM

A.F.F

1

A.F.C

2

4

2

2

2

4

2

CONFERENCE

ROOM

2

4

A.F.C

4

2

4

D1

2

1

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN) :

SMALL CONFERENCE ROOM # 01

AT EACH 85" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

01 x 6/16 AMP UPS POWER SUPPLY SOCKET

W / [1] 1" Ø CONDUIT STUBBED UP TO MONITOR AND LAID UNTIL MASTER

CONTROL ROOM.

2

AT EACH 65" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

01 x 6/16 AMP UPS POWER SUPPLY SOCKET

W / [1] 1" Ø CONDUIT STUBBED UP TO MONITOR AND LAID UNTIL MASTER

CONTROL ROOM.

3

AT EACH WALL - MOUNTED CAMERA LOCATION PROVIDE:

02 x 6/16 AMP UPS POWER SUPPLY SOCKET;

01 x DATA / LAN POINT;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER

CONTROL ROOM.

4

AT TABLE CABLE CUBBY LOCATION PROVIDE :

02 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

02 x DATA / LAN POINT ;

01 x 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM.

**LEAVE [2] 1" Ø CONDUITS FOR CEILING SPEAKERS **

**LEAVE EXTRA CONDUITS (04 X 1" Ø) FOR MICROPHONES ON TABLE**

Page 125 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV14.A2

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - SMALL CONF. ROOM # 01

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

1

3

1903.4MM

1364.5MM

1

DWG NO.:

AV15.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

3600MM

PROJECT MANAGEMENT CONSULTANTS

1250MM

3

1100MM

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN) :

SMALL CONFERENCE ROOM # 01

AT EACH 85" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

01 x 6/16 AMP UPS POWER SUPPLY SOCKET

W / [1] 1" Ø CONDUIT STUBBED UP TO MONITOR AND LAID UNTIL MASTER

CONTROL ROOM.

AT EACH WALL - MOUNTED CAMERA LOCATION PROVIDE:

02 x 6/16 AMP UPS POWER SUPPLY SOCKET;

01 x DATA / LAN POINT;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER

CONTROL ROOM.

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION - SMALL CONF. ROOM # 01

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 126 of 145

1

3

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

2

1467,4

1

AV ELECTRICAL NOTES (SECTIONAL PLAN) :

SMALL CONFERENCE ROOM # 01

AT EACH 85" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

01 x 6/16 AMP UPS POWER SUPPLY SOCKET

W / [1] 1" Ø CONDUIT STUBBED UP TO MONITOR AND LAID UNTIL MASTER

CONTROL ROOM.

2

AT EACH 65" WALL MOUNTED LED MONITOR LOCATION PROVIDE :

01 x 6/16 AMP UPS POWER SUPPLY SOCKET

W / [1] 1" Ø CONDUIT STUBBED UP TO MONITOR AND LAID UNTIL MASTER

CONTROL ROOM.

3

AT EACH WALL - MOUNTED CAMERA LOCATION PROVIDE:

02 x 6/16 AMP UPS POWER SUPPLY SOCKET;

01 x DATA / LAN POINT;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

DWG NO.:

AV16.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

SECTION - CONFERANCE ROOM # 01

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 127 of 145

1

1

1 J

3

1

1

2

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN) :

SMALL CONFERENCE ROOM # 02

AT 109" DIAGONAL PROJECTION SCREEN LOCATION PROVIDE:

01 x 6/16 AMP UPS POWER SUPPLY SOCKET W / [1] 1" Ø CONDUIT

STUBBED UP TO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 48.5 KG

SIZE - 57 1/2" H x 92" W (1460.5MM H X 2336.8MM W)]

** CHANGE THE ORIENTATION OF TABLE IMPROVE SIGHT LINES **

AT EACH CEILING MOUNTED PROJECTOR LOCATION PROVIDE :

03 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

02 x SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 1000 WATTS

WEIGHT - 34 KG

SIZE - 566MM L X 660MM W X 313MM H

3

AT WALL - MOUNTED CAMERA LOCATION PROVIDE :

02 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

01 x DATA / LAN POINT ;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

4

AT TABLE CABLE CUBBY LOCATION PROVIDE :

02 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

02 x DATA / LAN POINT ;

01 x 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM.

**LEAVE [2] 1" Ø CONDUITS FOR CEILING SPEAKERS **

**LEAVE EXTRA CONDUITS (04 X 1" Ø) FOR MICROPHONES ON TABLE**

Page 128 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV17.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - SMALL CONF. ROOM # 02

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

1

1

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

500MM

820.5MM

DWG NO.:

AV18.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

1460.5MM

2336.8MM

109" DIAGONAL

SCREEN

3600MM

PROJECT MANAGEMENT CONSULTANTS

1

3

1400MM

3

1219MM

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN):

SMALL CONFERENCE ROOM # 01

AT 109" DIAGONAL PROJECTION SCREEN LOCATION PROVIDE:

01 x 6/16 AMP UPS POWER SUPPLY SOCKET W / [1] 1" Ø CONDUIT

STUBBED UP TO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 48.5 KG

SIZE - 57 1/2" H x 92" W (1460.5MM H X 2336.8MM W)]

** CHANGE THE ORIENTATION OF TABLE IMPROVE SIGHT LINES **

AT WALL - MOUNTED CAMERA LOCATION PROVIDE :

02 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

01 x DATA / LAN POINT ;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION - SMALL CONF. ROOM # 02

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 129 of 145

1

3

1400MM

1461MM

1219MM

3600MM

1

2

3

AV ELECTRICAL NOTES (SECTIONAL PLAN) :

SMALL CONFERENCE ROOM # 02

AT 109" DIAGONAL PROJECTION SCREEN LOCATION PROVIDE:

01 x 6/16 AMP UPS POWER SUPPLY SOCKET W / [1] 1" Ø CONDUIT

STUBBED UP TO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 48.5 KG

SIZE - 57 1/2" H x 92" W (1460.5MM H X 2336.8MM W)]

** CHANGE THE ORIENTATION OF TABLE IMPROVE SIGHT LINES **

AT EACH CEILING MOUNTED PROJECTOR LOCATION PROVIDE :

03 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

02 x SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 1000 WATTS

WEIGHT - 34 KG

SIZE - 566MM L X 660MM W X 313MM H

AT WALL - MOUNTED CAMERA LOCATION PROVIDE :

02 x 6/16 AMP UPS POWER SUPPLY SOCKET ;

01 x DATA / LAN POINT ;

01 x SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

Page 130 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV19.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

SECTION - CONFERANCE ROOM # 02

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

+150 MM

A.F.F

REVISION

HISTORY:

1

2

4

3

00 03.01.13

FOR REVIEW M.S.

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN) :

TRAINING ROOM # 01

AT 137" PROJECTION SCREEN LOCATION PROVIDED:

02 X 6/16 AMP UPS POWER SUPPLY SOCKET W[1] 1"Ø CONDUIT

STUBBED UPTO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 63 KG

SIZE - 72 1/2" H x 116" W (1841.5 MM H X 2946.4 MM W)]

AT CEILING MOUNTED PROJECTOR PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA/ LAN POINTS;

02 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 871 WATTS

WEIGHT - 27 KG

SIZE - 500MM W X 561MM L X 259MM H]

DWG NO.:

AV1A.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

AT WALL MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINT;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF WALL PLATE:

LOAD - 11 WATTS

WEIGHT - 403 GRAMS

SIZE - 105MM H X 89MM W X 69MM D]

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AT TOUCH-SCREEN (WALL MOUNTED) LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT STUBBED UP-TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 WATTS

WEIGHT - 400 GRAMS

SIZE - 121MM X 193 MM X 52MM (H X W X D)]

** LEAVE [2] 1" Ø CONDUITS FROM MASTER CONTROL TO CEILING FOR CEILING SPEAKERS**

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - TRAINING ROOM # 01

CONFIDENTIALITY STATEMENT :

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 131 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

1

3600MM

209MM

4

350MM

137"

DIAGONAL SCREEN

DWG NO.:

AV1B.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

1219MM

3

150MM

1150MM

300MM

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN) :

TRAINING ROOM # 01

1

AT 137" PROJECTION SCREEN LOCATION PROVIDED:

02 X 6/16 AMP UPS POWER SUPPLY SOCKET W[1] 1"Ø CONDUIT

STUBBED UPTO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 63 KG

SIZE - 72 1/2" H x 116" W (1841.5 MM H X 2946.4 MM W)

]

3 AT WALL MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINT;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF WALL PLATE:

LOAD - 11 WATTS

WEIGHT - 403 GRAMS

SIZE - 105MM H X 89MM W X 69MM D]

4 AT TOUCH-SCREEN (WALL MOUNTED) LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT STUBBED UP-TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 WATTS

WEIGHT - 400 GRAMS

SIZE - 121MM X 193 MM X 52MM (H X W X D)]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION PLAN - TRAINING ROOM # 01

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 132 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

1

209MM

1842MM

3650MM

4

3

150MM

1219MM

1

2

3

4

300MM

AV ELECTRICAL NOTES (SECTIONAL PLAN):

TRAINING ROOM # 01

AT 137" PROJECTION SCREEN LOCATION PROVIDED:

02 X 6/16 AMP UPS POWER SUPPLY SOCKET W[1] 1"Ø CONDUIT

STUBBED UPTO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 63 KG

SIZE - 72 1/2" H x 116" W (1841.5 MM H X 2946.4 MM W)]

AT CEILING MOUNTED PROJECTOR PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA/ LAN POINTS;

02 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 871 WATTS

WEIGHT - 27 KG

SIZE - 500MM W X 561MM L X 259MM H]

AT WALL MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINT;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF WALL PLATE:

LOAD - 11 WATTS

WEIGHT - 403 GRAMS

SIZE - 105MM H X 89MM W X 69MM D]

AT TOUCH-SCREEN (WALL MOUNTED) LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT STUBBED UP-TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 WATTS

WEIGHT - 400 GRAMS

SIZE - 121MM X 193 MM X 52MM (H X W X D)]

Page 133 of 145

DWG NO.:

AV1C.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

SECTION PLAN - TRAINING ROOM # 01

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

1

3

DWG NO.:

AV1D.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

1

2

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN):

TRAINING ROOM # 01

AT 137" PROJECTION SCREEN LOCATION PROVIDED:

02 X 6/16 AMP UPS POWER SUPPLY SOCKET W[1] 1"Ø CONDUIT

STUBBED UPTO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 63 KG

SIZE - 72 1/2" H x 116" W (1841.5 MM H X 2946.4 MM W)]

AT CEILING MOUNTED PROJECTOR PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA/ LAN POINTS;

02 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 871 WATTS

WEIGHT - 27 KG

SIZE - 500MM W X 561MM L X 259MM H]

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

3

4

AT WALL MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINT;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF WALL PLATE:

LOAD - 11 WATTS

WEIGHT - 403 GRAMS

SIZE - 105MM H X 89MM W X 69MM D]

AT TOUCH-SCREEN (WALL MOUNTED) LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT STUBBED UP-TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 WATTS

WEIGHT - 400 GRAMS

SIZE - 121MM X 193 MM X 52MM (H X W X D)]

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - TRAINING ROOM # 02

CONFIDENTIALITY STATEMENT :

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 134 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

1

3600MM

209MM

4

350MM

137"

DIAGONAL SCREEN

DWG NO.:

AV1E.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

1219MM

3

1150MM

PROJECT MANAGEMENT CONSULTANTS

150MM

300MM

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN) :

TRAINING ROOM # 02

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

1

AT 137" PROJECTION SCREEN LOCATION PROVIDED:

02 X 6/16 AMP UPS POWER SUPPLY SOCKET W[1] 1"Ø CONDUIT

STUBBED UPTO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 63 KG

SIZE - 72 1/2" H x 116" W (1841.5 MM H X 2946.4 MM W)

]

3

AT WALL MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINT;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF WALL PLATE:

LOAD - 11 WATTS

WEIGHT - 403 GRAMS

SIZE - 105MM H X 89MM W X 69MM D]

4

AT TOUCH-SCREEN (WALL MOUNTED) LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT STUBBED UP-TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 WATTS

WEIGHT - 400 GRAMS

SIZE - 121MM X 193 MM X 52MM (H X W X D)]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION PLAN - TRAINING ROOM # 02

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 135 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

1

2

3

4

AT 137" PROJECTION SCREEN LOCATION PROVIDED:

02 X 6/16 AMP UPS POWER SUPPLY SOCKET W[1] 1"Ø CONDUIT

STUBBED UPTO SCREEN SWITCH AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 63 KG

SIZE - 72 1/2" H x 116" W (1841.5 MM H X 2946.4 MM W)]

AT CEILING MOUNTED PROJECTOR PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA/ LAN POINTS;

02 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTOR:

LOAD - 871 WATTS

WEIGHT - 27 KG

SIZE - 500MM W X 561MM L X 259MM H]

AT WALL MOUNTED PLATE LOCATION PROVIDE :

01 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINT;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF WALL PLATE:

LOAD - 11 WATTS

WEIGHT - 403 GRAMS

SIZE - 105MM H X 89MM W X 69MM D]

AT TOUCH-SCREEN (WALL MOUNTED) LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT STUBBED UP-TO ACCESSIBLE CEILING AND LAID UNTIL MASTER CONTROL ROOM;

[TENTATIVE DETAILS OF TOUCH PANEL:

LOAD - 13 WATTS

WEIGHT - 400 GRAMS

SIZE - 121MM X 193 MM X 52MM (H X W X D)]

Page 136 of 145

DWG NO.:

AV1F.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

SECTIONAL PLAN - TRAINING ROOM # 02

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

MASTER

CONTROL

ROOM

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN):

MASTER CONTROL ROOM

1

AT A/V RACK LOCATION PROVIDE :

04 X 6/16 AMP UPS POWER SUPPLY SOCKET;

04 X DATA/LAN POINTS.

2

AT TABLE LOCATION LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA / LAN POINTS;

01 X SINGLE GANG J- BOX @ FLOOR LOCATION W / [1] 1"Ø CONDUIT TO A/V RACK.

**TABLE LOCATION TO BE DECIDED BY CLIENT**

Page 137 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV1G.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM FIRST FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - MASTER CONTROL ROOM

CONFIDENTIALITY STATEMENT :

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

CD

CD

CD CD

CD

Page 138 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV20.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM SECOND FLOOR PLAN

SHEET TITLE :

SECOND FLOOR, CLASSIFICATION OF ROOMS

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

D1

D1

+116.30 LVL

+113.00LVL

FD1

+110.375 LVL

DN

CONTROL

ROOM

D4a

D4a

1

D4a

D4a

2

ROOM

9

D4a

IP BOOTH - 3

J

8

LIFT

D4a

D4a

IP BOOTH - 2

IP BOOTH - 1

10

F.F

10

10

AISLE

F.F

10

F.F

D4a

Partition stacking

10

F.F

10

F.F

10

F.F

10

F.F

10

F.F

10

F.F

+4148 MM

A.F.F

6

A.F.C

2

11

J

F.F

10

F.F

10

AISLE

10

F.F

F.F

10

A.F.C

2

6

3

A.F.C

6

3

F.F

10

F.F

10 F.F

10

F.F

AISLE

10

F.F

F.F

10

F.F

4

2

12

A.F.C

9

204 SEATS

J

196 SEATS

+113.00LVL

+113.60LVL

+114.05 +114.50

+114.95 +115.40

+115.85

+3040 MM

A.F.F

STAGE

+107.95 LVL

2

2

D4a

D4a

6

A.F.C

PIT

3

4

F.F

4

+106.85 LVL

AISLE

3

F.F

10

F.F

10

F.F

10

6

F.F

10

F.F

10

+4148 MM

A.F.F

9

A.F.C

ROOM

F.F

10

F.F

10

F.F

10

F.F

10

J

IP BOOTH - 3

D4a

8

F.F

IP BOOTH - 2

10

F.F

10

F.F

10

F.F

10

F.F

10

F.F

D4a

IP BOOTH - 1

10

F.F

10

F.F

10

F.F

Partition stacking

10

F.F

10

+2363 MM

A.F.F

A.F.C

6

2

D4a

LIFT

9

+1400MM

A.F.F

A.F.C

6

9

2

204 SEATS

11

F.F

4

2

12

A.F.C

2

7

13

CONTROL

ROOM

+5225 MM

A.F.F

196 SEATS

D3

D1

D1

DN

D4a

D4a

D4a

D4a

D3

+116.90 LVL

D3

IP BH - 1

D4a

IP BH - 2

D4a

IP BH - 3

D4a

IP BH - 4

D4a

IP BH - 5

CONTROL

ROOM

D4a

D4a

FD1

D1

+116.30LVL

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN):

MAIN AUDITORIUM

1

DIRECT LED,6MM WITH VIDEO WALL.[ 7.6M X 4.3M(W X H)]

2

AT FLOOR LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN DROP;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF FLOOR BOX:

LOAD - 11 WATTS

WEIGHT - 403 GRAMS

SIZE - 105 MM X 89 MM X 68 MM ( H X W X D )]

3

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT LAID UP-TO CONTROL ROOM;

[TENTATIVE DETAILS OF MONITOR SPEAKERS;

LOAD -

WEIGHT - 16 KG

SIZE - 573.5 X 352.8 X 398.6 MM (H X W X D)]

4 AT FLOOR LOCATION PROVIDE (FOR CONFIDENCE MONITOR) :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN DROP;

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF FLOOR BOX:

LOAD - 18 WATTS

WEIGHT - 463 GRAMS

SIZE - 155 MM H X 143 MM W X 26 MM D]

6 AT CEILING LOCATION PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X SINGLE GANG J- BOX W / [3] 1" Ø CONDUIT FROM CEILING TO CONTROL ROOM;

[TENTATIVE DETAILS OF EACH L.A SPEAKER:

LOAD -

WEIGHT - 21 KG

SIZE - 349 MM X 597 MM X 381 MM (H X W X D)]

7

AT MIXING CONSOLE(FLOOR) LOCATION PROVIDE:

04 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA/ LAN DROP;

01 X SINGLE GANG J- BOX W / [5] 1" Ø CONDUIT LAID UPTO CONTROL ROOM.

[TENTATIVE DETAILS OF AV MIXING CONSOLE:

LOAD - 130 WATTS

WEIGHT - 25.1 KG

SIZE - 250 MM X 1022 MM X 635 MM (H X W X D)]

8

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF ANTENNA;

LOAD -

WEIGHT - 250 GRAMS

SIZE - 240 MM L X 230 MM H X 26 MM W]

9

AT EACH WALL MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINTS;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

10 AT FLOOR LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X SINGLE GANG J- BOX W / [3] 1" Ø CONDUIT FROM CEILING TO CONTROL ROOM;

[TENTATIVE DETAILS OF EACH DELEGATE UNIT:

LOAD - 4 WATTS

WEIGHT - 1.45 KG

SIZE - 44 MM X 482 MM X 108 MM ( H X W X D )]

11

AT 240" DIAGONAL PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 189.6 KG

SIZE - 3657.6 MM H X 4876.8 MM W (144" H X 192"W)]

12

AT PROJECTOR LOCATION (CEILING) INSTALLED IN A LIFT PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA/ LAN POINTS;

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT FROM CEILING TO CONTROL ROOM;

[TENTATIVE DETAILS OF OF PROJECTOR:

LOAD - 4000 WATTS

WEIGHT - 73 KG

SIZE - 815 X 621 X 419 MM (L X W X H)]

13

4X4, NARROW BAZEL ,LED BACK LIT LCD MONITOR BASED VIDEO WALL [4.8M X 2.7 M,(W X H) ]

Page 139 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV21.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM SECOND FLOOR PLAN

SHEET TITLE :

FLOOR PLAN - MAIN AUDITORIUM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

1

7600MM

9 9

4300MM

4148MM

5

1800MM

5

STAGE

5 5 5

4139MM

1

AV ELECTRICAL NOTES (ELECTRICAL FLOOR PLAN):

MAIN AUDITORIUM

DIRECT LED,6MM WITH VIDEO WALL.[ 7.6M X 4.3M(W X H)]

5

AT STAGE LOCATION PROVIDE (FLOOR) :

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT FROM FLOOR LOCATION LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS FOR LIP SPEAKERS;

LOAD -

WEIGHT - 12.8 KG

SIZE - 469.9 X 237.5 X 254 MM (H X W X D)]

9

AT EACH WALL MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINTS;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

Page 140 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV22.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM SECOND FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION - MAIN AUDITORIUM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

1

CONTROL ROOM

STAGE

6

9

10

+110.375 LVL

+113.00 LVL

1

AV ELECTRICAL NOTES (SECTIONAL PLAN) :

MAIN AUDITORIUM

DIRECT LED,4MM WITH VIDEO WALL.[ 7.6M X 4.3M(W X H)]

6

AT CEILING LOCATION PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X SINGLE GANG J- BOX W / [3] 1" Ø CONDUIT FROM CEILING TO CONTROL ROOM;

[TENTATIVE DETAILS OF EACH L.A SPEAKER:

LOAD -

WEIGHT - 21 KG

SIZE - 349 MM X 597 MM X 381 MM (H X W X D)]

AT WALL LOCATION PROVIDE :

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF ANTENNA;

LOAD -

WEIGHT - 250 GRAMS

SIZE - 240 MM L X 230 MM H X 26 MM W]

9 AT WALL LOCATION PROVIDE :

18 X 6/16 AMP UPS POWER SUPPLY SOCKETS

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF VIDEO WALL (4 X 4 CONFIG);

LOAD -

WEIGHT - 600 KGS

SIZE - 4860 MM W X 120 MM D X 2460 MM H]

Page 141 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV23.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

CLIENT:

DRAWING TITLE:

AUDITORIUM SECOND FLOOR PLAN

SHEET TITLE :

SECTION - MAIN AUDITORIUM

CONFIDENTIALITY STATEMENT :

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

10515MM

11

EXTRA CLOTH

240" DIAGONAL

SCREEN

3658MM

4877MM

2316MM

1451MM

WHEN PARTITION IS CLOSED

11

240" DIAGONAL

SCREEN

3658MM

1451MM

WHEN PARTITION IS OPEN

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

DWG NO.:

AV24.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN):

LHS AUDITORIUM

11

AT 240" DIAGONAL PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 189.6 KG

SIZE - 3657.6 MM H X 4876.8 MM W (144" H X 192"W)]

CLIENT:

DRAWING TITLE:

AUDITORIUM SECOND FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION - LHS AUDITORIUM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 142 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

3658MM

11

6

Stage in raised position

9

5225MM

12

+109.775 LVL

+110.375 LVL

+113.0 LVL

IP BOOTH

+116.90 LVL

11

3658MM

6

Stage in raised position

9

5225MM

2316MM

+109.775 LVL

+110.375 LVL

12

+113.0 LVL

WHEN PARTITION IS OPEN

WHEN PARTITION IS CLOSED

AV ELECTRICAL NOTES (SECTIONAL PLAN):

LHS AUDITORIUM

6

AT CEILING LOCATION PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X SINGLE GANG J- BOX W / [3] 1" Ø CONDUIT FROM CEILING TO CONTROL ROOM;

[TENTATIVE DETAILS OF EACH L.A SPEAKER:

LOAD -

WEIGHT - 21 KG

SIZE - 349 MM X 597 MM X 381 MM (H X W X D)]

9

AT EACH WALL MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINTS;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

11

AT 240" DIAGONAL PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL

THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 189.6 KG

SIZE - 3657.6 MM H X 4876.8 MM W (144" H X 192"W)]

12

AT PROJECTOR LOCATION (CEILING) INSTALLED IN A LIFT PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA/ LAN POINTS;

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT FROM CEILING TO CONTROL ROOM;

[TENTATIVE DETAILS OF OF PROJECTOR:

LOAD - 4000 WATTS

WEIGHT - 73 KG

SIZE - 815 X 621 X 419 MM (L X W X H)]

IP BOOTH

+116.90 LVL

DWG NO.:

AV25.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM SECOND FLOOR PLAN

SHEET TITLE :

SECTION - LHS AUDITORIUM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 143 of 145

10515MM

REVISION

HISTORY:

11 11

00 03.01.14

FOR REVIEW M.S.

EXTRA CLOTH

240" DIAGONAL

SCREEN

3658MM

DWG NO.:

AV26.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

240" DIAGONAL

SCREEN

3658MM

PROJECT MANAGEMENT CONSULTANTS

2316MM

4877MM

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

1451MM

WHEN PARTITION IS CLOSED

1451MM

WHEN PARTITION IS OPEN

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

AV ELECTRICAL NOTES (FRONT ELEVATION PLAN):

RHS AUDITORIUM

11

AT 240" DIAGONAL PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 189.6 KG

SIZE - 3657.6 MM H X 4876.8 MM W (144" H X 192"W)]

CLIENT:

DRAWING TITLE:

AUDITORIUM SECOND FLOOR PLAN

SHEET TITLE :

FRONT ELEVATION - RHS AUDITORIUM

CONFIDENTIALITY STATEMENT:

1.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

2. THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

4.

DIMENSIONS ARE TO BE FOLLOWED.

ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 144 of 145

REVISION

HISTORY:

00 03.01.14

FOR REVIEW M.S.

3658MM

11

6

Stage in raised position

9

5225MM

12

+109.775 LVL

+110.375 LVL

+113.0 LVL

IP BOOTH

+116.90 LVL

11

3658MM

6

Stage in raised position

9

5225MM

2316MM

+109.775 LVL

+110.375 LVL

12

+113.0 LVL

WHEN PARTITION IS OPEN

WHEN PARTITION IS CLOSED

AV ELECTRICAL NOTES (SECTIONAL PLAN):

RHS AUDITORIUM

6

AT CEILING LOCATION PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X SINGLE GANG J- BOX W / [3] 1" Ø CONDUIT FROM CEILING TO CONTROL ROOM;

[TENTATIVE DETAILS OF EACH L.A SPEAKER:

LOAD -

WEIGHT - 21 KG

SIZE - 349 MM X 597 MM X 381 MM (H X W X D)]

9

AT EACH WALL MOUNTED CAMERA LOCATION PROVIDE :

02 X 6/16 AMP UPS POWER SUPPLY SOCKET;

01 X DATA/ LAN POINTS;

01 X SINGLE GANG J- BOX W / [1] 1" Ø CONDUIT LAID UPTO CONTROL ROOM;

[TENTATIVE DETAILS OF CAMERA:

LOAD - 25 WATTS

WEIGHT - 2.63 KG

SIZE - 198.4 X 169.4 X 179.3 MM (H X W X D)]

11

AT 240" DIAGONAL PROJECTION SCREEN LOCATION PROVIDE:

01 X 6/16 AMP UPS POWER SOCKET;

01 X SINGLE-GANG J-BOX W[1] 1"Ø CONDUIT STUBBED UPTO CEILING AND LAID UNTIL

THE CONTROL ROOM.

[TENTATIVE DETAILS OF PROJECTION SCREEN:

LOAD - 50 WATTS

WEIGHT - 189.6 KG

SIZE - 3657.6 MM H X 4876.8 MM W (144" H X 192"W)]

12

AT PROJECTOR LOCATION (CEILING) INSTALLED IN A LIFT PROVIDE :

03 X 6/16 AMP UPS POWER SUPPLY SOCKET;

02 X DATA/ LAN POINTS;

01 X SINGLE GANG J- BOX W / [2] 1" Ø CONDUIT FROM CEILING TO CONTROL ROOM;

[TENTATIVE DETAILS OF OF PROJECTOR:

LOAD - 4000 WATTS

WEIGHT - 73 KG

SIZE - 815 X 621 X 419 MM (L X W X H)]

IP BOOTH

+116.90 LVL

DWG NO.:

AV27.A1

SHEET:

A3

SCALE:

1:1

AV CONSULTANTS

3C DESIGN NETWORKS

LG-17, AVIOR, OPP. J&J FACTORY,

L B S ROAD, MULUND WEST,

MUMBAI - 80

MAHARASHTRA, INDIA.

T/F: +91 22 25610762

E: [email protected]

PROJECT MANAGEMENT CONSULTANTS

THE INFRASTRUCTURE PEOPLE

R I T E S LIMITED

RITES BHAVAN NO.01

SECTOR-29, GURGAON 122001

INDIA

ASSOCIATE ARCHITECTS:

AADHARSHILA DESIGNS PVT. LTD.

B - 4/124, L. G. F., Safdarjung Enclave, New Delhi - 110029.

Telefax -26100433/34, E-mail: [email protected]

ARCHITECTURE INTERIOR DESIGN ENGINEERING PLANNING CONSTRUCTION MANAGEMENT

# 10, KARPAGAMBAL NAGAR,

MYLAPORE, CHENNAI-600 004

PROJECT:

PROPOSED BUILDING PLAN FOR CONSTRUCTION

OF AUDITORIUM BUILDING IN THE EXISTING

NATIONAL AGRICULTURAL SCIENCE CENTRE (N.A.S.C)

COMPLEX, ON TODAPUR-INDERPURI ROAD (DPS MARG),

NEW DELHI

CLIENT:

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH (ICAR), KRISHI BHAVAN,

DR. RAJENDRA PRASAD MARG,

NEW DELHI

DRAWING TITLE:

AUDITORIUM SECOND FLOOR PLAN

SHEET TITLE :

SECTION - RHS AUDITORIUM

CONFIDENTIALITY STATEMENT:

1.

2.

THIS DRAWING IS A PROPERTY OF 3C DESIGN

NETWORKS AND CANNOT BE USED WITHOUT PRIOR

WRITTEN PERMISSION.

THIS DRAWING HAS TO BE READ ALONG WITH

RELEVANT DRAWINGS.

3. DRAWING SHALL NOT BE SCALED AND WRITTEN

DIMENSIONS ARE TO BE FOLLOWED.

4. ALL MEASUREMENTS MUST BE CHECKED ON SITE BY

THE CONTRACTOR OR ANY OTHER AGENCIES

REFERRING TO THIS DRAWING.

5. DISCREPANCIES MUST BE REPORTED IMMEDIATELY

TO 3C DESIGN NETWORKS BEFORE PROCEEDING

WITH THE WORK.

Page 145 of 145

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement