Ballasts: T12 Electronic and High Output

Ballasts: T12 Electronic and High Output
Table of Contents
T12 Electronic and High Output Ballasts
Ballasts
gelighting.com
T8 Instant Start
Understanding T12 Electronic Ballasts........................14-2
T8 Programmed
Start
ProLine® T12
For F20 (2 ft), F30 (3 ft),
F34/F40 (4 ft) T12 Lamps........................................................ 14-3
For T12 4 ft – 8 ft
Slimline Lamps............................................................................ 14-6
T12 High Output................................................................14-7
Wiring Diagrams...............................................................14-8
Case Dimensions..............................................................14-9
Programmed
Start Dimming
T5 Electronic
Programmed Start
T12 Electronic
& High Output
T12 Magnetic
Sign
Compact
Fluorescent
14-1
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
Understanding T12
Electronic Ballasts
Electronic T12
GE multivolt and dedicated voltage ProLine® T12 high-performance ballasts are designed for
replacement of magnetic T12 electronic ballasts during maintenance or retrofits. GE multivolt
ProLine® T12 ballasts have the same wiring and mounting requirements as standard magnetic
ballasts and provide up to 20% energy savings by simply replacing the ballast.
The DOE ballast ruling effective April 1, 2005, prevents the sale of 4 foot and 8 foot lamp
­electro­magnetic ballasts that operate T12 lamps and do not meet federal ballast efficiency
requirements. GE ProLine® T12 electronic ballasts meet the DOE minimum ballast efficiency
requirements and also allow facility managers to reduce ballast maintenance inventories by
consolidating the number of ballasts needed. GE ProLine® T12 ballasts operate both energysaving and standard wattage lamps and are also multi-voltage (120-277V). With 2 ballasts, the
multi-voltage ProLine® T12 can consolidate over 40 different magnetic ballasts.
Performance Features
• GE240RSMVN and GE240RS120 comply
with FCC for residential use
• Low-profile and lightweight housing
­simplifies installation and reduces
­transportation costs (GE240 = 1.3 lbs. lighter
than magnetic; GE260 = 5.3 lbs. lighter than
magnetic)
•P
arallel operation — if one lamp fails,
others remain lit
• Significantly quieter than magnetic
• High-frequency operation virtually
­eliminates lamp flickering typical in T12
electromagnetic systems
• Five-year limited ballast warranty
Electromagnetic T12
• Complete line of ballasts for 2-to-8 foot
lamps, circleline and high-output lamps
• 100% thermally protected
• High-grade lamination steel assures lowest
wattage loss
• UL, CSA and/or cUL approved
• 888-GEBALLAST on every ballast
• Two-year limited ballast warranty
Color-Coded Ballast and Outer Box Labels
120V – Yellow
277V – Red
Packaging
• Standard 10 packs
• IP Packs – individually packed with
­instructions
• DIY – shrink-wrapped and tray-packed
with instructions
GE Ballast LFL magnetic nomenclature
G E M - 2
GE Ballast
M = Electromagnetic
Ballast
GEH = HID
Maximum ­number of
lamps supported by
this ballast: 1, 2, 3, 4
14-2
3 2 - H O - R S - 1 2 0 - D I Y
Lamp Watts
(Primary Lamp)
T8 = 32 – 4 foot,
59 – 8 foot
T12 = 40 – 4 foot,
60 – 8 foot
T12 Electronic =
40 – 2-4 foot, 2 pin
60 – 4-8 foot, 1 pin
96 – 4-8 foot HO,
2 pin
T12 Magnetic =
40 – 2-4 foot, 2 pin
96 – 4-8 foot, 2 pin
IS = Instant Start,
default if not shown
RS = Rapid Start
PH = Preheat
PT= Preheat/Trigger
H = Hybrid
D50 = Dimming (min level)
= High Output
HO
VHO = Very High Output
120V – Yellow
277V – Red
220V – Green
240V – Orange
347 – Gray
Pack Type
IP = Individual corrugated
box per ballast
84T = Pallet bulk pack
(84=840, 42=420 ballasts)
DIY = Shrinkwrap ballast in
tray pack
DIY72 = Shrinkwrap ballast
in pallet pack (Qty)
No extension = 10 pack
See page E-1 for warranty information.
ProLine T12
T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps
74472 – GE240RS-MV-N (replaces 24107)
ProLine® T12 Multivolt 120V – 277V
2 or 1 – F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12
Dimensions
General characteristics
70°C (158°F)
Normal
Active
A (20-24 decibels)
Metal
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
60 Hz
Order information
Std. pack
74472
Pallet Pack
DIY Pack
74473 (replaces 24773)
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
48.0 in (1219 mm)
33.0 in (838 mm)
33.0 in (838 mm)
25.0 in (635 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F40T10
F34T12
F30T12/WM
F20T12
Safety and performance
System Watts
74
73
48
48
75
72
42
42
63
62
41
41
50
50
30
30
60
58
37
37
46
45
28
29
Nom. Line Current
0.67 A
0.30 A
0.41 A
0.19 A
0.63 A
0.27 A
0.35 A
0.17 A
0.56 A
0.26 A
0.35 A
0.17 A
0.42 A
0.20 A
0.26 A
0.13 A
0.31 A
0.22 A
0.31 A
0.16 A
0.39 A
0.18 A
0.24 A
0.13 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.89
0.89
Ballast Efficacy Factor
1.20
1.22
0.88
0.88
1.17
1.22
0.87
0.87
1.38
1.40
0.95
0.95
1.90
1.90
0.95
0.95
1.58
1.64
1.00
1.00
2.17
2.22
UL Class P
NRCan
Power Factor% (>=)
99
97
99
95
99
94
99
88
99
96
99
94
99
91
99
82
99
96
99
94
99
94
99
92
FCC Part 18 Class B at 120 volts
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
6
10
7
10
7
16
10
16
7
10
8
11
9
18
12
27
7
10
8
11
8
11
9
17
Min. Starting Temp (°F/°C)
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
T12 Electronic
& High Output
F30T12
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F40T12
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
Programmed
Start Dimming
Wiring diagram – LFL PS2 – see example on page 14-8
Case dimensions – Ref Drawing B1 – see page 14-9
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote mounting distance to lamp
Remote Mounting Wire Gauge
Lead lengths
Yellow
Blue
Red
Black
White
Electronic – Programmed/ Rapid Start
Rapid start
Parallel
10%
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
T8 Instant Start
• High-performance electronic ballast for all general fluorescent applications
• Multi-voltage technology handles voltage from 120 to 277V
• Light weight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
®
UL Listed RoHS compliant
T12 Magnetic
Sign
Compact
Fluorescent
14-3
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T12
T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps
97498 – GE240RS120
• High-performance electronic ballast for all general fluorescent applications
• Light weight, low-profile housing
ProLine® T12 120V
2 – F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Programmed / Rapid Start
Rapid start
Series
10%
221°F (105°C)
70°C (158°F)
Normal
Passive
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL PS2 – see example on page 14-8
Case dimensions – Ref Drawing B1 – see page 14-9
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White and Black
Blue and Red
Yellow
Yellow
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
Std. pack
97498
Pallet Pack
DIY Pack
97499
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.0 in (25 mm)
8.9 in (226 mm)
0.9 in (22 mm)
0.3 in (8 mm)
1.38 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
33 in (838 mm)
48 in (1219 mm)
36 in (914 mm)
Specifications by lamp and wattage
Lamp
F25T12
FT36W/4P
F34T12
F30T12
F12T9
F8T9
F16T9
# of Lamps
2
2
2
2
2
2
1
1
1
Line Volts
120
120
120
120
120
120
120
120
120
System Watts
73
70
63
62
59
59
Safety and performance
CSA
Nom. Line Current
0.62 A
0.60 A
0.54 A
0.53 A
0.50 A
0.50 A
UL Type 1 Outdoor
System Ballast Factor
1.10
0.58
0.85
0.85
0.92
0.53
ANSI – 62.41
UL Type HL
Ballast Efficacy
1.50
0.82
1.34
1.37
1.55
0.89
Power Factor % (>=)
1
0.98
98
96
0.92
0.95
FCC Part 18 Class B at 120 volts
UL Class P
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
ANSI – C82.11
THD (<=)
20
20
20
25
25
0.53
UL Listed
Min. Starting Temp (°F/°C)
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
NRCan
75672 – GE140RS120
ProLine® T12 120V
1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF ProLine® T12
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Programmed/ Rapid Start
Rapid start
Parallel
10%
105°F (41°C)
75°C (167°F)
Normal
Active
A (20-24 decibels)
End-of-Life Protection (EOL), Thermally protected
Wiring diagram – LFL 2 – see example on page 14-8
Case dimensions – Ref Drawing 29 – see page 14-9
Length (L)
6.46 in (164 mm)
Width (W)
1.37 in (35 mm)
Height (H)
1.0 in (25 mm)
Mounting dimensions
Mount Length (M)
6.0 in (152 mm)
Mount Width (X or F)
1.37 in (35 mm)
Mount Slots (MS)
Weight
Exit Type
Side
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths*
Length (± 1 in)
Blue and Red
25 in (635 mm)
White and Black
15 in (381 mm)
* See gelighting.com for wire lengths. Different for 10 pg vs. DIY pack.
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
Std. pack
75672
Pallet Pack
DIY Pack
72110
IP Pack
Specifications by lamp and wattage
Lamp
F40T12/40W
F40T12/25W
F34T12/34W
F30T12/30W
# of Lamps
1
1
1
1
Line Volts
120
120
120
120
Safety and performance
14-4
System Watts
36
36
30
28
Nom. Line Current
0.53 A
0.53 A
0.45 A
0.41 A
Meets FCC Part 18 (Class B) Consumer Limits
System Ballast Factor
0.88
1.33
0.88
0.93
cUL Listed
Ballast Efficacy Factor
2.44
3.69
2.93
3.32
UL Listed
Power Factor % (>=)
57
57
55
58
Crest Factor (<=)
1.58
1.54
1.50
1.51
THD (<=)
150
150
150
150
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
ANSI 62.41
See page E-1 for warranty information.
ProLine T12
T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12, F40T10 Lamps
24109 – GE340RS-MV-N
ProLine® T12 Multivolt 120V – 277V
3 or 2 – F40 or F34T12 Rapid Start 120 to 277 ProLine® T12
General characteristics
Dimensions
Electronic – Programmed / Rapid Start
Rapid start
Parallel
10%
105°F (41°C)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
Std. pack
24109
Pallet Pack
DIY Pack
24774
IP Pack
9.5 in (241 mm)
2.3 in (60 mm)
1.5 in (39 mm)
8.9 in (226 mm)
1.6 in (40 mm)
0.3 in (8 mm)
2.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
33 in (838 mm)
33 in (838 mm)
25 in (635 mm)
48 in (1219 mm)
Specifications by lamp and wattage
Lamp
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.89
0.89
Ballast Efficacy Factor
0.78
0.80
0.87
0.87
0.90
0.92
FCC – CLASS A Non-Consumer
UL Class P
Power Factor % (>=)
99
97
99
96
99
97
99
96
99
96
99
95
99
97
95
99
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD (<=)
5
11
6
12
5
12
6
13
6
12
7
13
5
12
13
6
Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
T12 Electronic
& High Output
Safety and performance
Nom. Line Current
0.98 A
0.43 A
0.74 A
0.33 A
90.00 A
0.39 A
0.67 A
0.30 A
0.81 A
0.36 A
0.60 A
0.27 A
0.75 A
0.33 A
0.25 A
0.55 A
T5 Electronic
Programmed Start
# of Lamps
Line Volts
System Watts
3
120
114
3
277
111
2
120
86
F40T12
2
277
85
3
120
107
3
277
105
2
120
80
F40T10
2
277
79
3
120
96
3
277
94
2
120
71
F34T12
2
277
70
3
120
90
3
277
87
2
277
67
F30T12
2
120
66
Other compatible lamps: F30T12/WM, F40T12/WMP
Programmed
Start Dimming
Wiring diagram – LFL PS3 – see example on page 14-8
Case dimensions – Ref Drawing ST – see page 14-9
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
Red/White
White and Black
Yellow
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T8 Instant Start
• High-performance electronic ballasts for all general fluorescent applications
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
®
UL Listed
T12 Magnetic
Sign
Compact
Fluorescent
14-5
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T12
T12 Electronic and High Output Ballasts For T12 4 ft – 8 ft Slimline Lamps
74474 – GE-260IS-MV-N (replaces 24108)
• High-performance electronic ballasts for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T12 Multivolt 120V – 277V
2 or 1 – F96T12 Instant Start 120 to 277
Dimensions
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Wiring diagram – LFL 14 – see example on page 14-8
Case dimensions – Ref Drawing B1 – see page 14-9
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
White
Red
Blue
Electronic - Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50Hz/60 Hz
Order information
10 Pack
74474
Pallet Pack
DIY Pack
74475 (replaces 24776)
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
2.40 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
25.0 in (635 mm)
59.0 in (1499 mm)
67.0 in (1702 mm)
Specifications by lamp and wattage
Lamp
F96T12/WMP
F96T12/WM
F96T12
F84T12
F72T12
F64T12
F60T12
F48T12
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
14-6
System Watts
107
106
68
68
112
110
72
71
141
138
90
89
125
123
80
79
107
106
69
69
97
96
63
63
92
91
60
60
73
73
49
48
Nom. Line Current
0.94 A
0.40 A
0.60 A
0.27 A
0.98 A
0.42 A
0.63 A
0.28 A
1.24 A
0.53 A
0.79 A
0.34 A
1.10 A
0.47 A
0.70 A
0.30 A
0.94 A
0.40 A
0.60 A
0.27 A
0.86 A
0.37 A
0.55 A
0.25 A
0.81 A
0.35 A
0.53 A
0.28 A
0.65 A
0.29 A
0.43 A
0.20 A
UL Type 1 Outdoor
NRCan
System Ballast Factor
0.88
0.88
1.00
1.00
0.90
0.90
1.00
1.00
0.90
0.90
1.02
1.02
0.90
0.90
1.04
1.04
0.90
0.90
1.04
1.04
0.90
0.90
1.08
1.08
0.90
0.90
1.08
1.08
0.90
0.90
1.10
1.10
UL Type HL
Ballast Efficacy Factor
0.82
0.83
1.47
1.47
0.80
0.82
1.39
1.41
0.64
0.65
1.13
1.15
0.72
0.73
1.30
1.32
0.84
0.85
1.51
1.51
0.93
0.94
1.71
1.71
0.98
0.99
1.80
1.80
1.23
1.23
2.24
2.29
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
96
99
95
99
97
99
95
99
98
99
96
99
97
99
96
99
97
99
95
99
97
99
95
99
96
99
94
99
95
99
89
UL Class P
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
8
10
10
12
8
10
10
12
8
10
10
12
8
10
10
12
8
10
10
12
8
10
10
12
8
10
10
12
8
10
10
12
Min. Starting Temp (°F/°C)
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
RoHS compliant
See page E-1 for warranty information.
T12 High Output
T12 Electronic and High Output Ballasts
T8 Instant Start
75671 – GE296HO-MV-N
T12 High Output ProLine® T12 Multivolt 120V – 277V
2 or 1 – F96T12 HO RS 120 to 277 Multivolt ProLine®
General characteristics
Dimensions
Electronic – Programmed/ Rapid Start
Rapid start
Series
10%
105°F (41°C)
75°C (167°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL PS2 – see example on page 14-8
Case dimensions – Ref Drawing SL – see page 14-9
Length (L)
11.75 in (299 mm)
Width (W)
2.15 in (55 mm)
Height (H)
1.61 in (41 mm)
Mounting dimensions
Mount Length (M)
11.0 in (279 mm)
Mount Width (X or F)
2.15 in (55 mm)
Mount Slots (MS)
Weight
Exit Type
Side
Remote Mounting Distance to Lamp*
Remote Mounting Wire Gauge
* See gelighting.com for wire lengths. Different for 10 pg vs. DIY pack.
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Std. pack
75671
Pallet Pack
DIY Pack
72109
IP Pack
Specifications by lamp and wattage
Lamp
F96T12/HO/
WM
F70T8
F60T12/HO
F48T12/HO
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
System Watts
164
164
196
196
104
104
154
154
120
119
132
132
112
113
cUL Listed
Nom. Line Current
1.38 A
0.62 A
1.65 A
0.73 A
0.88 A
0.42 A
1.30 A
0.57 A
1.17 A
0.52 A
0.50 A
0.50 A
0.95 A
0.43 A
UL Listed
System Ballast Factor
0.90
0.90
0.90
0.90
0.92
0.92
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
Ballast Efficacy Factor
0.55
0.55
0.46
0.46
0.88
0.88
0.58
0.58
0.75
0.76
0.68
0.68
0.80
0.80
Power Factor % (>=)
99
99
99
97
99
95
99
96
99
97
96
96
99
95
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
15
15
10
10
10
10
10
10
15
15
Min. Starting Temp (°F/°C)
60.0/16
60.0/16
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
T5 Electronic
Programmed Start
F96T12/HO
F72T12/HO
# of Lamps
2
2
2
2
1
1
2
2
2
2
2
2
2
2
Programmed
Start Dimming
Order information
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Ballasts
gelighting.com
FCC Part 18 (Class A) Non Consumer
T12 Electronic
& High Output
T12 Magnetic
Sign
Compact
Fluorescent
14-7
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
Wiring Diagrams
T12 Electronic and High Output Ballasts
LFL PS2
LFL PS3
LFL 14
LFL 2
14-8
See page E-1 for warranty information.
Case Dimensions
T12 Electronic and High Output Ballasts
T8 Programmed
Start
SL
T12 Electronic
& High Output
T12 Magnetic
Sign
Compact
Fluorescent
HID Electronic &
Electromagnetic
14-9
See page E-1 for warranty information.
T5 Electronic
Programmed Start
D10, 15, 29
Programmed
Start Dimming
B1
T8 Instant Start
ST
Ballasts
gelighting.com
T12 Electronic and High Output Ballasts
Notes
14-10
See page E-1 for warranty information.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement