Three-phase monitoring relay CM-PFE
Data sheet
Three-phase monitoring relay
CM-PFE
2CDC 251 005 S0012
The CM-PFE is a three-phase monitoring relay
that monitors the phase parameter phase
sequence and phase failure in three-phase mains.
Characteristics
–– Monitoring of three-phase mains for phase sequence and
phase failure
–– Powered by the measuring circuit
–– 1 c/o (SPDT) contact
–– 22.5 mm (0.89 in) width
–– 1 LED for the indication of operational states
Approvals
A UL 508, CAN/CSA C22.2 No.14
R
EAC
K
E
L
CB scheme
CCC
RMRS
Marks
a CE
b
C-Tick
Order data
Three-phase monitoring relay
Type
Rated control supply voltage = measuring voltage
Order code
CM-PFE
3 x 208-440 V AC
1SVR550824R9100
Functions
Operating controls
1 Indication of operational states
R: yellow LED – Relay status
2CDC 251 005 S0012
1
Application / Operating mode
The CM-PFE is designed for use in three-phase mains for monitoring the phase parameters phase sequence and phase
failure.
The CM-PFE works according to the closed-circuit principle.
Indication of operational states
LEDs, status information and fault messages
Operational state
R: LED yellow
Output relay energized
2 - Three-phase monitoring relay CM-PFE | Data sheet
V
Function descriptions / diagrams
Phase sequence and phase failure monitoring
If all phases are present with the correct phase sequence, the output relay energizes after the fixed start-up delay ts is
complete.
If a phase failure or a phase sequence error occurs, the fixed tripping delay tv starts. When timing is complete, the output
relay de-energizes. The LED R glows when the output relay is energized.
In case of motors which continue running with only two phases, the CM-PFE detects phase failure if the reverse fed voltage
is less than 60 % of the originally applied voltage.
L1, L2, L3
Measuring value
L1, L2, L3
t
L1, L3, L2
t
s
v
L1, L2, L3
t
s
L1, L2
t
v
L3
L1, L2, L3
t
s
2CDC 252 061 F0208
11-14
11-12
R: yellow LED
ts = Start-up delay fixed 500 ms
tv = Tripping delay fixed 500 ms
Electrical connection
L2
L1 L2 L3
L3
11-12/14
Output contact - closed-circuit principle
11
12 14
12
Control supply voltage = measuring voltage
11
14
1SVC 110 000 F0117
L1
L1, L2, L3
Connection diagram CM-PFE
Data sheet | Three-phase monitoring relay CM-PFE - 3
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
Input circuits
Supply circuit = measuring circuit
L1, L2, L3
Rated control supply voltage Us = measuring voltage
3 x 208-440 V AC
Rated control supply voltage Us tolerance
-10...+10 %
Rated frequency
50/60 Hz (-10...+10 %)
Typical current / power consumption
approx. 15 VA
Measuring circuit
L1, L2, L3
Monitoring functions
Phase failure
J
Phase sequence
Measuring ranges
J
3 x 208-440 V AC
Thresholds
U min
U max
0.6 x Un
Rated frequency of the measuring signal
50/60 Hz
Response time
500 ms
Accuracy within the rated control supply voltage tolerance
iU m 0.5 %
Accuracy within the temperature range
iU m 0.06 % / °C
Timing circuit
Start-up delay Ts
fixed 500 ms
Tripping delay Tv
fixed 500 ms
User interface
Indication of operational states
Relay status
R
yellow LED
Details see table ‚LEDs, status information and fault messages‘ on page 2 and ‚Function descriptions / diagrams‘ on page 3.
Output circuits
Kind of output
1 c/o (SPDT) contact
Operating principle
closed-circuit principle
Contact material
AgCdO
Rated operational voltage Ue (IEC/EN 60947-1)
250 V
Maximum switching voltage
250 V DC, 250 V AC
Rated operational current I e
AC12 (resistive) at 230 V
4A
(IEC/EN 60947-5-1)
AC15 (inductive) at 230 V
3A
DC12 (resistive) at 24 V
4A
DC13 (inductive) at 24 V
2A
AC rating (UL 508)
Utilization category
(Control Circuit Rating Code)
max. rated operational voltage
max. continuous thermal current at B 300
max. making/breaking apparent power
at B 300
Mechanical lifetime
Electrical lifetime
1)
1)
B 300
300 V AC
5A
3600/360 VA
30 x 106 switching cycles
AC12, 230 V, 4 A
0.1 x 10 6 switching cycles
Maximum fuse rating to achieve
n/c contact
10 A fast-acting
short-circuit protection
n/o contact
10 A fast-acting
Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold.
4 - Three-phase monitoring relay CM-PFE | Data sheet
General data
MTBF
on request
Duty time
100 %
Dimensions (W x H x D)
product dimensions
packaging dimensions
Weight
22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in)
24 x 83 x 25 mm (0.94 x 3.27 x 0.98 in)
net weight
0.068 kg (0.150 lb)
gross weight
0.080 kg (0.176 lb)
Mounting
DIN rail (IEC/EN 60715)
Mounting position
any
Degree of protection
housing
IP50
terminals
IP20
Electrical connection
Wire size
fine‑strand with wire end ferrule
fine‑strand without wire end ferrule
rigid
2 x 0.75-1.5 mm 2 (2 x 18-16 AWG)
2 x 1-1.5 mm 2 (2 x 18-16 AWG)
2 x 0.75-1.5 mm2 (2 x 18-16 AWG)
Stripping length
10 mm (0.39 in)
Tightening torque
0.6 - 0.8 Nm (5.31 - 7.08 lb.in)
Environmental data
Ambient temperature ranges
operation
-20...+60 °C
storage
-40...+85 °C
Damp heat, cyclic (IEC 60068-2-30)
24 h cycle time, 55 °C, 93 % rel., 96 h
Operational reliability (IEC 68-2-6)
6g
Mechanical resistance (IEC 68-2-6)
10 g
Isolation data
Rated insulation voltage Ui
supply circuit / measuring circuit
(VDE 0110, IEC/EN 60947-1)
Rated impulse withstand voltage Uimp
/ output circuit
all isolated circuits
(VDE 0110, IEC/EN 60664)
500 V
4 kV, 1.2/50 µs
Test voltage between all isolated circuits (routine test)
2.5 kV, 50 Hz, 1 min.
Pollution degree (VDE 0110, IEC/EN 60664, IEC/EN 60255-5)
3
Overvoltage category (VDE 0110, IEC/EN 60664, IEC/EN 60255-5)
III
Standards
Product standard
IEC/EN 60255-6
Low Voltage Directive
2006/95/EC
EMC directive
2004/108/EC
Electromagnetic compatibility
Interference immunity to
IEC/EN 61000-6-2
electrostatic discharge
IEC/EN 61000-4-2
Level 3 (6 kV / 8 kV)
radiated, radio-frequency,
IEC/EN 61000-4-3
Level 3 (10 V/m)
electrical fast transient / burst
IEC/EN 61000-4-4
Level 3 (2 kV / 5 kHz)
surge
IEC/EN 61000-4-5
Level 4 (2 kV L-L)
conducted disturbances, induced by
IEC/EN 61000-4-6
Level 3 (10 V)
electromagnetic field
radio-frequency fields
Interference emission
IEC/EN 61000-6-4
Data sheet | Three-phase monitoring relay CM-PFE - 5
Technical diagrams
Load limit curves
V
300
V
300
V 200
resistive load
20
20
10
0.1
0.2
0.5
1
2
I
4
6
10
A
2CDC 252 194 F0205
100
80
60
50
40
30
AC load (resistive)
0.2
Switching cycles
0.9
0.8
0.7
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
cos ϕ
1
2
I
4
6
10
A
250 V
resistive load
2CDC 252 192 F0205
0.6
0.5
0.5
DC load (resistive)
1.0
F
10
0.1
Derating factor F for inductive AC load
Switching current [A]
Contact lifetime
6 - Three-phase monitoring relay CM-PFE | Data sheet
2CDC 252 193 F0205
resistive load
100
80
60
50
40
30
2CDC 252 148 F0206
V 200
Dimensions
in mm and inches
88.5
22.5
3.48“
0.886“
78.5
2CDC 252 189 F0005
78
3.07“
81 3.19“
3.09“
Further documentation
Document title
Document type
Document number
Electronic products and relays
Technical catalogue
2CDC 110 004 C020x
You can find the documentation on the internet at www.abb.com/lowvoltage -> Control Products ->
Electronic Relays and Controls -> Three Phase Monitors.
CAD system files
You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/PARTcommunity/Portal/
abb-control-products -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls ->
Three Phase Monitors -> CM-PFx - Three Phase Monitors.
Data sheet | Three-phase monitoring relay CM-PFE - 7
Document number 2CDC 112 191 D0201 Rev B (08.2014)
Contact us
ABB STOTZ-KONTAKT GmbH
P. O. Box 10 16 80
69006 Heidelberg, Germany
Phone: +49 (0) 6221 7 01-0
Fax: +49 (0) 6221 7 01-13 25
E-mail: info.desto@de.abb.com
You can find the address of your
local sales organisation on the
ABB home page
http://www.abb.com/contacts
-> Low Voltage Products and Systems
Note:
We reserve the right to make technical changes
or modify the contents of this document without
prior notice. With regard to purchase orders, the
agreed particulars shall prevail. ABB AG does
not accept any responsibility whatsoever for
potential errors or possible lack of information in
this document.
We reserve all rights in this document and in
the subject matter and illustrations contained
therein. Any reproduction, disclosure to third
parties or utilization of its contents – in whole
or in parts – is forbidden without prior written
consent of ABB AG.
Copyright© 2014 ABB
All rights reserved