SECURITY DOOR CONTROLS
www.sdcsecurity.com [email protected]
[t] 800.413.8783 805.494.0622 [f] 805.494.8861
801 Avenida Acaso, Camarillo CA 93012 • PO Box 3670, Camarillo CA 93011-3670
Universal Door Control Modules
Field Programmable Access Hardware Controller
13 Field Selectable Station Modes & Systems
UR Series Universal Door Controllers provide a choice of individual dip
switch selectable relay operation modes or system modes lock control,
monitoring, communicating door or lock system logic. Relay output
modes may be individually configured as a Dry Contact or Voltage (Wet)
Output. Relays may be configured to work independently or in tandem
with adjacent relay. Features include:
• 4 selectable relay output modes
• 7 selectable mantrap & bathroom systems
• 3 system control inputs, On, Off, Lockout
• Emergency Release Input UR4-8 Shown
Benefits
• Use the same controller for all virtually
multi-door applications
• Centralized wiring for all locks, access controls,
monitoring contacts and peripheral equipment
• On board logic reduces need for communicating
door and lock contacts and standalone relays.
• Reduced wiring, easy troubleshooting
Station Capacity - 1 Relay Per Station
Select operation mode for each station.
Select station output configuration:
SPDT Dry contact or Wet output.
Wet output same as module input,
12 or 24VDC
UR2-4
4 NO inputs
4 Wet (1-On/1-Off) or SPDT Dry
(2 fused, 2 non-fused)
UR4-8
8 NO inputs
8 Wet (1-On/1-Off) or SPDT Dry
(4 fused, 4 non-fused)
Station Capacity - 2 Relays Per Station
Select operation mode for each station.
Select station output configuration, Wet or
Dry:
Wet output same as module input,
12 or 24VDC
UR2-4
4 NO inputs
2 fused Wet or Dry Outputs
2 non-fused Wet or Dry outputs
UR4-8
8 NO inputs
4 fused Wet or Dry Outputs
4 non-fused Wet or Dry outputs
Programmable Station Modes
Each output may be individually programmed
with its own mode of operation
• Conventional Relay
• Latching Relay, on/off
• Latch multi-station zones on/off or all
stations on/off
• Time Delay Relay 1-60 seconds
• Dual function Latching on/off, plus
1-60 second Timed output when on.
• Emergency Release Input may control
select stations or all stations
UR2-4 Specifications
Input Voltage: 12 or 24VDC +/- 10%
Input Current: 130mA max.
Relay Inputs: 4-SPST, NO Dry,
Optically Isolated
Auxiliary Inputs: 4-SPST, NO Dry,
Optically Isolated
Programmable System Modes
System selection provides appropriate mode
of operation for each input and output
• Airlock/Interlock Mode A: All doors
normally unlocked, opening any door
causes all other doors to lock.
Outputs Specification
Field Selectable Voltage Output or Dry
Contact
Outputs individually configured as a dry
contact or 12 or 24VDC Voltage Output, (1)
Normally (On) and 1 Normally (Off)
2 fused SPDT relays, 7 Amps @ 30VDC
2 non-fused SPDT relays, 7 Amps @ 30VDC
UR4-8 Specifications
Input Voltage: 12 or 24VDC +/- 10%
• Mantrap Mode B: All doors normally
locked. When any door is unlocked all other
doors are incapable of unlocking.
• 3 Mantrap Mode C: Select doors locked or
unlocked. When unlocked door is opened,
locked doors are incapable of unlocking.
When a locked door is unlocked, normally
locked doors lock and all other locked doors
are incapable of unlocking.
• Shared Hospital/Dorm Bathroom A:
Doors equipped with magnetic locks.
• Shared Hospital/Dorm Bathroom B:
Doors equipped with electrified locksets.
Input Current: 130mA max.
Relay Inputs: 8-SPST, NO Dry,
Optically Isolated
Auxiliary Inputs: 4-SPST, NO Dry,
Optically Isolated
Outputs Specification
Field Selectable Voltage Output or Dry
Contact
Outputs individually configured as a dry
contact or 12 or 24VDC Voltage Output, (1)
Normally (On) and 1 Normally (Off)
4 fused SPDT relays, 7 Amps @ 30VDC
4 non-fused SPDT relays, 7 Amps @ 30VDC
Individual Contact Configuration
Dimensions: 7" W x 5" H x 2" D
(177.8 x 127 x 50.8 mm)
Each relay may be configured as a dry
contact or voltage output.
Documentation
Several access control and mantrap system
wire diagrams are provided for common
applications.
SECURITY DOOR CONTROLS
© 2011 Security Door Controls LIT-Door Control Modules 2/11
sdcsecurity.com [email protected]
ISO 9001
FM 52705
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement