Everbilt ZE00804 is a non-submersible 12V utility pump designed for clean water transfer. With a 1/10 HP motor, it can pump up to 15 gallons per minute. It features a suction strainer to prevent debris from entering the pump and a garden hose adapter for easy connection to a standard garden hose. It is ideal for draining water from flooded areas, emptying pools or spas, or transferring water from one container to another.
advertisement
70*17mm logo
108*38mm
SKU 1001 093 988
Model ZE00804
Non-Submersible 12V Utility Pump
Bomba sumergible para no Utility 12V
12V DC 1/10HP
Serial No./Serial No.: 000000
Date Code/Código de Fecha: 1439
WARNING/ADVERTENCIA
• This pump is used for clean water only.
• This pump is not waterproofed. Do not submerge in any liquid.
• To increase impeller life, wet the impeller or fill out the inlet with water before connecting garden hoses.
• Never run the pump dry.
• Esta bomba se utiliza sólo agua limpia.
• Esta bomba no está impermeabilizado. No lo sumerja en ningún líquido.
• Para aumentar la vida del impulsor, mojar el impulsor o llene la entrada con agua antes de conectar las mangueras de jardín.
• Nunca haga funcionar la bomba en seco.
name plate
60*35mm
WARNING/ADVERTENCIA
You MUST use this suction strainer when using this pump. Push the clear hose into the rubber connection on the strainer. Failure to use this strainer WILL VOID WARRANTY!
Place the strainer in at least 1/2 in. of water at the lowest point to be pumped.
Debe utilizar este filtro de succión cuando se utiliza esta bomba.
Empuje la manguera transparente en la conexión de goma en el colador. Si no se utiliza este filtro ANULARÁ LA GARANTÍA!
Coloque el colador en al menos un medio en. De agua en el punto más bajo a bombear.
warning
42*42mm
IN
OUT You MUST hose onto INLET.
Pump must be unplugged when water is gone.
Debe adjuntar suministrado manguera transparente en ENTRADA.
La bomba debe ser desconectado cuando el agua se ha ido.
pump lable
40
Quick Start Guide
Non-Submersible 12V Utility Pump
1. Add water (approximately 1-2 Tbsp.) into the inlet to wet the impeller of the pump.
Read your manual for installation, operation, and safety information. This guide neither supplements nor replaces the Owner’s Manual.
DO NOT RUN PUMP DRY!
Dry running will void the warranty and damage pump.
2. Attach the clear suction hose (included) to the suction strainer (included) by pushing the male threaded end into the rubber coupler on the suction strainer. Then place the strainer in at least 1/2 in. of water at the lowest point to be pumped.
NOTICE: Make sure the connection is airtight. An air leak can cause the pump to run dry.
3. Thread the other end of the clear suction hose onto the suction inlet of the pump.
NOTICE: Always ensure the washer in the hose connector is not damaged. An airtight seal is necessary for this pump to operate.
Make sure the clear hose and suction strainer are in the water before plugging the pump in.
4. Thread a 5/8 in. or larger garden hose (sold separately, max
50 ft. length) to the discharge outlet on the pump.
NOTICE: Make sure the end of the outlet hose is not under water.
If the outlet is under water, the pump may not work.
NOTICE: Never operate this pump unless it is secured to a solid foundation.
5. Attach the pump to a sturdy base (table, board, etc.) to prevent it from tipping over. Make sure the hoses are as straight as possible.
WARNING: This pump CANNOT be submersed in water, and the motor CANNOT get wet at all. Getting the motor wet could cause electrocution, which could lead to serious injury or death!
NOTICE: Do not coil or kink the hose.
6. Connect the motor lead wires as indicated. The pump will start immediately when connected to power.
Power Supply: The pump is designed for use with a 12 Volt DC battery. Operation requires a minimum 12 Volt power supply.
When the water level has been reduced to approximately 1/8 in., you MUST CUT OFF THE POWER. DO NOT RUN DRY.
NOTICE: If water is not pumped in 30 seconds, cut off the power and check the connection on the two ends of the inlet hose to make sure there are no air leaks. Then, add water into the inlet again and repeat the process.
NO COILS!
NO KINKS!
Guía de Referencia Rápida
BOMBA SUMERGIBLE PARA NO UTILITY 12V
Es importante leer el manual para obtener información sobre la instalación, la operación y la seguridad.Esta guía no complementa ni reemplaza al Manual del Propietario.
NO HAGA FUNCIONAR LA BOMBA EN SECO!
El funcionamiento en seco, se anulará la garantía y el daño de la bomba.
1. Añada agua (aproximadamente 1 a 2 cucharadas) en la entrada para mojar el impulsor de la bomba.
2. Conecte la manguera de succión transparente (se incluye) en el colador de succión (se incluye) al empujar el extremo roscado macho en el acoplador de goma del colador de succión.
Coloque el colador al menos 1,27 cm en el punto más bajo de agua que sedebe bombear.
AVISO: Verifique que la conexión esté cerrada herméticamente.
Una fuga de aire puede hacer que la bomba funcione en seco.
3. Enrosque el otro extremo de la manguera de succión transparente a la entrada de succión de la bomba.
AVISO: Asegúrese siempre de que el conector de la manguera no esté dañado. Es necesario un sello hermético para que esta bomba funcione.
Asegúrese de que la manguera transparente y el colador de succión se encuentren en el agua antes de conectar la bomba
4. Enrosque una manguera de jardín de 1,59 cm o más grande (se vende por separado, longitud máx. de 15,24 m) en la salida de descarga de la bomba.
AVISO: Asegúrese de que el extremo de la manguera de salida no esté debajo del agua. Si la salida está bajo agua, puede que la bomba no funcione.
AVISO: Nunca haga funcionar esta bomba a menos que se fije a una base sólida.
5. Adhiera la bomba a una base fuerte (mesa, tabla, etc.) para evitar que se vuelque. Asegúrese de que las mangueras estén lo más rectas posibles.
ADVERTENCIA: Esta bomba NO PUEDE estar sumergida en agua y el motor NO PUEDE mojarse para nada. ¡Mojar el motor podría causar electrocución, lo que podría provocar lesiones graves o la muerte!
AVISO: No enrolle ni doble la manguera.
6. Conecte los cables conductores del motor según se indica. La bomba se iniciará inmediatamente cuando se conecta a la energía.
Fuente de alimentación: La bomba está diseñada para su uso con una batería de 12 voltios DC. La operación requiere una fuente de alimentación mínima de 12 voltios.
Cuando el nivel de agua se ha reducido a aproximadamente 1/8 pulg.,
DEBE CORTAR EL PODER. NO HAGA FUNCIONAR EN SECO.
AVISO: Si el agua no es bombeada en 30 segundos, cortar la alimentación y compruebe el onexión en los dos extremos de la manguera de entrada para asegurarse de que no hay fugas de aire. A continuación, agregue el agua en la entrada de nuevo y repetir el proceso.
NO BOBINAS!
Existan dobleces!
al menos de 1/2"
Non-Submersible 12V Utility Pump
–
.
.
Let Us Help You !
Permítanos Help !
Do not return your product to the store.
Call us first!
If you have questions regarding your product or require warranty assistance, please call our customer service toll-free helpline
No devuelva su proudct a la tienda.
Llámenos primero!
Si tiene alguna pregunta con respecto a su producto o si necesita asistencia con la garantía, por favor llame a nuestra línea de ayuda de servicio al cliente de gratis
1-844-241-5521
Contact us for assistance, we're here to help.
En contacto con nosotros para obtener ayuda, estamos aquí para ayudar.
advertisement