null  null
Human Machine Interface Systems/
PC-based Automation
SIMATIC HMI / PC-based Automation
Catalog
ST 80/
ST PC
Edition
2013
Answers for industry.
© Siemens AG 2013
Related catalogs
SIMATIC
Products for
Totally Integrated Automation
ST 70
E86060-K4670-A101-B4-7600
Industrial Communication
SIMATIC NET
IK PI
E86060-K6710-A101-B7-7600
SITOP
Power supply
SITOP
KT 10.1
E86060-K2410-A111-A9-7600
SITRAIN
Training for Automation and
Industrial Solutions
ITC
Only available in German
E86060-K6850-A101-C3
Products for Automation
and Drives
Interactive Catalog, DVD
E86060-D4001-A510-D2-7600
Mall
Information and Ordering Platform
in the Internet:
www.siemens.com/industrymall
CA 01
© Siemens AG 2013
SIMATIC HMI /
PC-based Automation
Operator Control and
Monitoring Systems
Introduction
1
Operator panels
2
HMI devices for special requirements
3
HMI Software
4
PC-based Automation
5
Customized Automation
6
Appendix
7
Catalog ST 80 / ST PC · 2013
The products and systems described in this
catalog are manufactured/distributed under
application of a certified
quality management
system in accordance
with DIN EN ISO 9001
(Certified Registration
No. 2613-05). The certificate is recognized by all
IQNet countries.
Supersedes:
Catalog ST 80 / ST PC · 2012
Refer to the Industry Mall for current updates
of this catalog:
www.siemens.com/industrymall
The products contained in this
catalog can also be found in the
Interactive Catalog CA 01.
Order No.:
E86060-D4001-A510-D2-7600
Please contact your local Siemens branch.
© Siemens AG 2013
Printed on paper
from sustainably
managed forests and
controlled sources.
www.pefc.org
© Siemens AG 2013
2
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Answers for industry.
Integrated technologies, vertical market expertise and services
for greater productivity, energy efficiency, and flexibility.
The Siemens Industry Sector is the
world's leading supplier of innovative
and environmentally friendly products
and solutions for industrial companies.
End-to-end automation technology and
industrial software, solid market expertise, and technology-based services are
the levers we use to increase our customers’ productivity, efficiency and
flexibility. With a global workforce of
more than 100 000 employees,
the Industry Sector comprises the
Industry Automation, Drive Technologies, and Customer Services divisions,
as well as the Metals Technologies
Business Unit.
We consistently rely on integrated technologies and, thanks to our bundled
portfolio, we can respond more quickly
and flexibly to our customers' wishes.
With our globally unmatched range of
automation technology, industrial
control and drive technology as well
as industrial software, we equip companies with exactly what they need over
their entire value chain – from product
design and development to production,
sales and service. Our industrial customers benefit from our comprehensive
portfolio, which is tailored to their
market and their needs.
Market launch times can be reduced by
up to 50% due to the combination of
powerful automation technology and
intelligent industrial software from
Siemens Industry. At the same time,
the costs for energy or waste water
for a manufacturing company can be
reduced significantly. In this way, we
increase our customers’ competitive
strength and make an important contribution to environmental protection
with our energy-efficient products and
solutions.
Siemens ST 80 / ST PC · 2013
3
© Siemens AG 2013
(53²(QWHUSULVH5HVRXUFH3ODQQLQJ
3/0²3URGXFW/LIHF\FOH0DQDJHPHQW
0DQDJHPHQW/HYHO
‡3URGXFW'HVLJQ
‡3URGXFWLRQ3ODQQLQJDQG6LPXODWLRQ
‡'DWD0DQDJHPHQW
0(6²0DQXIDFWXULQJ([HFXWLRQ6\VWHPV
6,0$7,&,7
2SHUDWLRQV/HYHO
0DLQWHQDQFH
$VVHW0DQDJHPHQW
6,0$7,&3&6
2SHUDWRU6\VWHP
(QHUJ\
0DQDJHPHQW
(QJLQHHULQJ
6WDWLRQ
7,$3RUWDO
&RQWURO/HYHO
6,0$7,&3&6
$XWRPDWLRQ
6\VWHPV
6,180(5,.
&RPSXWHU1XPHULF&RQWURO
6,027,21
0RWLRQ&RQWURO
6,0$7,&1(7
,QGXVWULDO
&RPPXQLFDWLRQ
6,0$7,&&RQWUROOHUV
0RGXODU3&EDVHG
)LHOG/HYHO
352),%863$
3URFHVV,QVWUXPHQWDWLRQ
7RWDOO\
,QWHJUDWHG
$XWRPDWLRQ
6,0$7,&'LVWULEXWHG,2
6,0$7,&,GHQW
,QGXVWULDO,GHQWLÀFDWLRQ
+$57
,2/LQN
Setting standards in
productivity and competitiveness.
Totally Integrated Automation.
4
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
TIA is characterized by its unique continuity.
It provides maximum transparency at all levels
with reduced interfacing requirements – covering
the field level, production control level, up to the
corporate management level. With TIA you also
profit throughout the complete life cycle of your
plant – starting with the initial planning steps
through operation up to modernization, where
we offer a high measure of investment security resulting from continuity in the further development
of our products and from reducing the number of
interfaces to a minimum.
3ODQW(QJLQHHULQJ
&2026
(WKHUQHW
6,0$7,&:LQ&&
6&$'$6\VWHP
The unique continuity is already a defined
characteristic at the development stage of
our products and systems.
,QGXVWULDO(WKHUQHW
6,0$7,&+0,
+XPDQ0DFKLQH,QWHUIDFH
The result: maximum interoperability – covering
the controller, HMI, drives, up to the process
control system. This reduces the complexity of
the automation solution in your plant. You will
experience this, for example, in the engineering
phase of the automation solution in the form of
reduced time requirements and cost, or during
operation using the continuous diagnostics facilities of Totally Integrated Automation for increasing the availability of your plant.
6,5,86,QGXVWULDO&RQWUROV
352),1(7
,QGXVWULDO(WKHUQHW
352),%86
6,1$0,&6'ULYH6\VWHPV
6,7233RZHU6XSSO\
$6,QWHUIDFH
.1;*$00$LQVWDEXV
/RZ9ROWDJH'LVWULEXWLRQ
7RWDOO\
,QWHJUDWHG
3RZHU
6,027,&60RWRUV
Thanks to Totally Integrated Automation, Siemens provides
an integrated basis for the implementation of customized
automation solutions – in all industries from inbound to
outbound.
Siemens ST 80 / ST PC · 2013
5
© Siemens AG 2013
Totally Integrated Power:
Future-proof power supply
from one source.
6
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Software tools, products, systems and
support for integrated electrical
power distribution
Energy Management/
Energy Transparency
Operation &
Monitoring
Load
management
Load curves
Forecast
Maintenance
Substation
Distribution
Maintenance
task
Status
reporting/
failure
management
Protocols
Power
Quality
DATE:
Cost center
EMPLOYEE
COST CENTER
PAY PERIOD BEGINNING
PAY PERIOD ENDING
DATE
SUN
MON
TUE
WED
THUR
FRI
SUN
MON
TUE
WED
THUR
FRI
SAT
SUN
TOTAL
IN
OUT
IN
OUT
OVERTIME
TOTAL HOURS
DATE
SAT
SUN
TOTAL
IN
OUT
U
I
cos o
P
W
IN
Hall 1
Distribution 3
Process/
industrial automation
Products & Systems
Infeed II
Renewables
Medium voltage with
protection technology
Air conditioning system
checkup
Replacing circuit
breaker contacts
Replacing meters
OUT
OVERTIME
TOTAL HOURS
central ON
OFF
local ON
OFF
tripped
Transformer
DATE
SUN
MON
TUE
WED
THUR
FRI
SAT
SUN
TOTAL
IN
OUT
IN
OUT
Building
automation
OVERTIME
TOTAL HOURS
Low voltage with
protection and measuring technology
≤ 110 kV
Planning Software Tools
The power supply system acts like a
“vital artery”, forming the basis for
the reliable and efficient functioning
of all electrically operated building
installations. Electrical power distribution therefore requires integrated
solutions. Our answer:
Totally Integrated Power (TIP).
This includes software tools and
support for planning and configuration
and a complete, optimally aligned
product and system portfolio for
integrated power distribution from
medium-voltage switchgear right to
socket outlets.
Network dimensioning
with SIMARIS design
Space requirements and budget calculation
with SIMARIS project
The power distribution products and
systems can be interfaced to building
or industrial automation systems
(Total Building Solutions or
Totally Integrated Automation) via
communication-capable circuit breakers
and components, allowing the full potential for optimization that an integrated solution offers to be exploited
throughout the project cycle – from
planning right through to installation
and operation.
Visualization of device characteristics
with SIMARIS curves
Get more information:
www.siemens.com/tip
www.siemens.com/simaris
www.siemens.com/specifications
Siemens ST 80 / ST PC · 2013
7
© Siemens AG 2013
8
Siemens ST 80 / ST PC · 2013
1
© Siemens AG 2013
Operator control and
monitoring systems /
PC-based Automation
1/2
1/2
1/8
Introduction
SIMATIC HMI operator control and
monitoring systems
SIMATIC PC-based Automation
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Introduction
Gain transparency and lower costs
1
SIMATIC HMI operator control and
monitoring systems
■ Overview
The interface between human and machine –
the human machine interface or HMI for short –
connects the world of automation with the
individual requirements of the operator.
Human machine interfacing is about managing
the process, optimizing machine and system
operation, availability and productivity.
1/2
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Introduction
Gain transparency and lower costs
SIMATIC HMI operator control and
monitoring systems
■ Overview (continued)
Everything from a single source
Integrated into the World Wide Web
With SIMATIC HMI, Siemens Automation and Drives offers a
complete range of innovative and low-cost products and
systems for the multi-faceted tasks of operator control and
monitoring: Ranging from operator panels and visualization
software for operator control and monitoring at the machine
through to SCADA systems for widely differing requirements in
process visualization. For special requirements, optimally
adapted products are offered such as especially rugged HMI
devices with all-round protection for mounting on support arms/
pedestals, or operator panels with stainless steel front for use in
the food and beverages industry. Of course, individual,
customer-specific requirements can also be implemented.
SIMATIC HMI makes the Internet into a control desk - within a
plant as well as in the worldwide network.
Perfectly equipped for integration
in the world of automation
With their open, standardized interfaces in hardware and
software, SIMATIC HMI products can be integrated at any time
in the production and automation level as well as in the company
management level. Connectability to almost every controller on
the market as well as multiple language capability of the configuration and visualization software – including Asian ideographic
languages, of course – facilitate operation worldwide.
Using the WinCC/Web Navigator, you can monitor and operate
plants over the Internet or over the internal corporate intranet.
Thin client solutions can be used to integrate rugged, local
devices which simultaneously establish the connection between
the automation level and the control center. And over a wireless
LAN or cell phone connection, you can use mobile thin clients
such as laptop computers, PDAs (personal digital assistants) or
WebPads.
In this way, process, service or management information can be
made individually available to users. At the machine level, many
control units support remote operation, e.g. as a link between
the automation level and the control room through to service and
diagnostics over the Internet.
For operation and monitoring at the machine, concepts with socalled [email protected] and servers facilitate plant-wide access to
variables and graphics, distributed operator stations as well as
remote operation and diagnostics via the Internet – also in
conjunction with SIMATIC Panels.
www.siemens.com/simatic-hmi
Increased production transparency
through Plant Intelligence
Plant Intelligence is based on the intelligent utilization of information to improve processes within the company.
It is designed to lower plant costs, consolidate and improve
quality, avoid wastage, utilize production facilities better and
ultimately ensure greater efficiency and cost effectiveness within
the company. WinCC provides the best requirements for
achieving this since WinCC features an integrated Historian for
acquiring important production data.
Using intelligent functions and tools, this process data can be
edited into information necessary for making decisions and can
be made available throughout the company whenever and
wherever it is required – for operators as well as production
managers or anyone else within the company.
Even the WinCC basic system provides a wealth of display and
evaluation functions, such as the statistics function for the
message and measured value logs. WinCC options for IT &
business integration make additional "smart" tools available for
optimizing production using Plant Intelligence.
Siemens ST 80 / ST PC · 2013
1/3
1
© Siemens AG 2013
Introduction
Gain transparency and lower costs
1
SIMATIC HMI operator control and
monitoring systems
■ Overview (continued)
Traceability and easy validation
More than just operator control and monitoring
SIMATIC HMI software with "FDA options" provides a high
degree of support to machine and plant manufacturers who
must fulfill high quality requirements, both with respect to the
products to be manufactured as well as to the manufacturing
processes themselves.
The Multi Panels under Windows CE combine the advantages of
two worlds: On the one hand, the ruggedness of an operator
panel and on the other hand the flexibility typical of a PC.
These options simplify plant validation enormously and thus
provide the most convincing and comprehensive solution for the
requirements of these industries.
They support the user in fulfilling high quality requirements as
specified by the FDA (Food and Drug Administration) 21 CFR
Part 11 for the food, beverages and pharmaceutical industries.
Increased plant availability
All operator panels and Panel PCs are designed for harsh industrial use. Redundant process visualization systems ensure a
high degree of plant availability during normal operation.
Distributed operator control concepts
SIMATIC HMI offers different solutions for different requirements
for operator control of large machines and plants spread over
extensive areas.
Thus, the [email protected] option of the SIMATIC WinCC flexible
visualization software, for example, allows HMI devices such as
panels, Thin Clients and PCs plant-wide access via PROFINET/
Ethernet to current process values and the local screen images
of all involved stations.
SIMATIC HMI software offers appropriate options for
diagnostics, maintenance and telecontrol over the Internet from
local operator stations.
As remote operator stations, SIMATIC Thin Clients make the
functionality of machine-level panels available in the control
room or in the office, thanks to their connection to PROFINET/
Ethernet, and in the other direction, they bring SIMATIC WinCC
or office or IT functionality straight to the machine.
In PC-based applications, a SIMATIC Flat Panel monitor can take
over the function of the operating unit from PCs, such as
SIMATIC Rack or Box PC, at a distance of up to 30 m.
1/4
Siemens ST 80 / ST PC · 2013
Apart from classical operator control and monitoring, other
automation functions such as control functions can execute
simultaneously. And for PC-based automation, the SIMATIC
Panel PCs are available as a compact automation platform - the
embedded versions being especially compact and rugged as
well as maintenance-free.
© Siemens AG 2013
Introduction
Gain transparency and lower costs
SIMATIC HMI operator control and
monitoring systems
■ Overview (continued)
All the advantages of Totally Integrated Automation
Investment protection is included
With Totally Integrated Automation (TIA), Siemens is the only
supplier who offers a system-wide, integrated product and
system range for automating the complete production workflow.
The distinguishing feature of TIA is that it is completely
integrated. The reduced number of interfaces results in very
clear structures.
Our many years of experience in the automation engineering
sector are to your advantage. The same applies to our global
service network with its expert support.
Further services, such as a software update service, training,
ordering over the Internet, etc. round off what we have to offer.
This reduces time and costs required for engineering the
automation solution and increases the availability of the plant.
In conjunction with other SIMATIC components, SIMATIC HMI
also supports system diagnostics and process diagnostics
during normal operation. You can start STEP 7 diagnostics
directly from WinCC for comprehensive error diagnostics from
the circuit diagram through to the PLC program.
The SIMATIC Maintenance Station visualizes the maintenance
information for the automation technology of a system – from the
controller and network components to switchgear, protective
equipment and control devices and the drives.
This gives a clear overview of the status of the automation at any
time.
A competent partner for automation solutions
With SIMATIC HMI, you not only get excellent products to suit
your requirements, we will also support you when selecting a
partner for your automation solution. In our worldwide network of
Siemens Automation Solution Partners, you will find competent
contact partners in your area who are always up-to-date with
SIMATIC HMI technology.
The Siemens-internal WinCC Competence Centers implement
technology-specific products as well as customer and industryspecific solutions on the basis of WinCC.
WinCC specialists are external system integrators who combine
their WinCC expertise with their industry and technology knowhow to create tailor-made, cost-effective solutions. Numerous
products from our partners that perfectly interact with WinCC are
available as WinCC Add-ons.
Siemens ST 80 / ST PC · 2013
1/5
1
© Siemens AG 2013
Introduction
A whole world of operator control and monitoring
1
SIMATIC HMI operator control and
monitoring systems
SIMATIC® HMI®
HMI devices
SIMATIC HMI Key Panels
Operator panels with bus capability for easy and direct
operation of machines.
www.siemens.com/key-panels
SIMATIC HMI Basic Panels
Operator panels with basic functionality for low-cost operator
control and monitoring of simple applications.
www.siemens.com/basic-panels
Process
visualization
Single-user PC
SIMATIC HMI Comfort Panels
HMI devices with high-end functionality for demanding
applications.
www.siemens.com/comfort-panels
SIMATIC HMI Mobile Panels
Mobile operator panels with or without cables for direct operator
control of the plant and machine from any location.
www.siemens.com/simatic-mobile-panels
HMI devices for special requirements
Operator control
and monitoring
directly at the
machine
Key Panels
Basic Panels
Fully enclosed HMI devices for SIMATIC
The fully enclosed SIMATIC HMI devices (MP 377 PRO,
HMI IPC477C PRO, Flat Panel PRO and Thin Client PRO) are
ideal for industrial applications in harsh environments due to
their extremely robust design. They are, for example, specially
designed for mounting on a support arm/stand.
www.siemens.com/ip65-hmi-devices
Devices with stainless steel fronts
Panels and Panel PCs with touch screens and stainless steel
fronts are designed for machine-level operator control and
monitoring in the food, beverages and tobacco industry.
www.siemens.com/inox-hmi-devices
SIMOTION
Motion Control
HMI devices for hazardous areas
Intrinsically safe Panel PCs and Thin Clients that were specifically developed for hazardous areas.
www.siemens.com/simatic-hmi-ex
HMI software
Flexibility in any HMI application – from Basic Panels through to
process visualization
Actuators / Sensors
SIMATIC WinCC in the Totally Integrated Automation Portal
(TIA Portal) is part of a new, integrated engineering framework
which offers a uniform engineering environment for
programming and configuration of control, visualization and
drive solutions.
WinCC in the TIA Portal is the software for all HMI applications
ranging from the simplest operation solutions with Basic Panels
to SCADA applications on PC-based multi-user systems.
www.siemens.com/tia-portal
SIMATIC WinCC V7 remains available for extremely complex
applications featuring Plant Intelligence solutions, integrated
archive servers or redundant architectures, whereas WinCC
Open Architecture addresses applications with demanding
customization requirements, also on non-Windows platforms.
www.siemens.com/wincc
WinCC Open Architecture adressiert Anwendungen mit
hohem kundenspezifischen Anpassungsbedarf – auch auf
Nicht-Windows-Plattformen.
www.siemens.com/wincc-open-architecture
1/6
Siemens ST 80 / ST PC · 2013
Customized Automation
With Customized Automation, field-proven SIMATIC,
SIMATIC IPC and SIMATIC HMI standards are transferred to
individual products and systems – tailored precisely to the
customer's requirements. The portfolio covers the hardware and
software range, as well as support and logistics.
www.siemens.com/customized-automation
© Siemens AG 2013
Introduction
A whole world of operator control and monitoring
SIMATIC HMI operator control and
monitoring systems
Enterprise Resource Planning (ERP)
Manufacturing Execution Systems (MES)
Plant Intelligence
Client/Server
Mobile Panels
Panel PCs
Flat Panel monitors
SIMATIC Controller
S7-200 S7-1200
Field devices
S7-400
SCADA system WinCC
Software HMI
WinCC (TIA Portal)
Thin Clients
Additional automation systems
S7-300
Drives
G_ST80_XX_00365
Comfort Panels
Internet client
Siemens ST 80 / ST PC · 2013
1/7
1
© Siemens AG 2013
Introduction
■ Overview
SIMATIC
Thin Client
SIMATIC WinCC
Visualization
Archive
Databases
SIMATIC Field PG
Configuration
Programming
STEP 7
PROFINET
Industrial Ethernet
SIMATIC S7
SIMATIC Panel PC
WinCC, WinAC
Software PLC
SIMATIC Rack PC
SIMATIC Box PC
Nanobox PC/Microbox PC
WinAC (F)
Software PLC
WinAC (F)
Software PLC
SIMATIC Embedded Bundles:
IPC2x7D/IPC4x7C
S7-modular Embedded Controller
PROFINET
PROFIBUS
SIMATIC HMI Panel
Operator control and
monitoring
ET 200
SIMOTION D / SINAMICS / MICROMASTER
G_ST70_XX_00169
1
SIMATIC PC-based Automation
SIMATIlC PC-based Automation
Embedded bundles with industrial PCs
www.siemens.com/pc-based
Embedded bundles based on the embedded industrial PCs are
extremely compact, robust, and maintenance-free systems for
use at machine level. The functions PC-based Control (also failsafe) and/or visualization are already pre-installed and ready to
use.
Industrial PCs
Our reliable and innovative industrial PCs are the optimal PC
hardware platform for PC-based Automation from Siemens.
www.siemens.com/simatic-ipc
PC-based controllers
www.siemens.com/simatic-embedded-bundles
Software packages for SIMATIC IPCs
Siemens has developed a wide range of coordinated hardware
and software components for PC-based Automation. Focal
point: SIMATIC PC-based Control with SIMATIC WinAC, the
open, flexible and reliable software controller for your PC-based
automation solution, also approved by the German Technical
Inspectorate and fail-safe.
SIMATIC industrial PCs are offered with low-cost software
packages. For the runtime versions with the visualization
software products SIMATIC WinCC or WinCC Professional,
WinCC flexible or WinCC Advanced, as well as the software
controller SIMATIC WinAC RTX (F). The simultaneous purchase
of industrial PC and software package results in the price
advantage.
www.siemens.com/winac
www.siemens.com/simatic-ipc-packages
Embedded controllers
Industrial monitors and thin clients
SIMATIC S7-mEC is a modular controller in S7-300 design with
the latest embedded PC technology. It comprises the EC31
(CPU) as well as the optionally available expansion modules.
Flexible distributed operating concepts can be implemented via
Flat Panel monitors and thin clients. These are industry-standard
LCD monitors with high-luminance displays that are placed up
to 30 m away from the PC, or high-performance industrial thin
clients. SIMATIC ITC, for one or even several operator stations,
can be placed as far away as required via Industrial Ethernet.
www.siemens.com/simatic-s7-mec
www.siemens.com/simatic-ifp
www.siemens.com/simatic-itc
1/8
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
■ Overview (continued)
Measurement of foil thickness
Application examples
www.siemens.com/pc-based-applications
During the manufacture of
plastic films, a highly accurate
and uniform foil thickness over
the entire width is a decisive
quality criterion.
For this purpose, a measuring
head with radioactive source
moves back and forth above the
film and perpendicular to the
continuously transported reel,
and a sensor moves underneath
the foil.
Unit-type cogeneration unit
When redesigning unit-type
cogeneration units, the
automation approach should
also be restructured. The
objective was to execute all
control, visualization and
archiving tasks which were
previously handled by a PLC
and a PC on a compact unit.
Space was to be saved in the
control cabinet, and the administration and training requirements reduced. At the same
time a rugged, maintenancefree device was required which can also be easily connected
over the Internet.
The advantages of the solution with SIMATIC PC-based
Automation:
• Microbox PC IPC427C as a rugged, compact embedded
system
- Control, visualization and archiving of the process parameters in one device
- Space and cost savings thanks to integration of several
tasks on a single embedded industrial PC
Previously: one PLC and one visualization PC
• Easy and quick access to the embedded IPC over the Internet
Router
E-mail
SIMATIC HMI IPC577
Remote control
station
2 x ET 200S with
motor starter
2 x ET 200S
DI/DO
The advantages of the solution with SIMATIC PC-based
Automation:
• Visualization is performed using WinCC, and control using
WinAC RTX on a PC.
• Complex mathematical algorithms are required for evaluation
of the extensive measured data.
• These are meaningfully implemented in the high-level
language C++. Seamless and high-performance integration
of these algorithms into the STEP 7 program is via the ODK
(Open Development Kit).
• Data exchange between WinAC RTX and WinCC, for visualization of the extensive measured curves, takes place very
quickly via the hard drive cache. This functionality was also
implemented via the ODK.
• Interconnection of the standardized technology function is via
CFC (Continuous Function Chart).
WinCC
WinAC RTX
Visual C++
CP 5613 A2
Analysis of the
measured data
The plant concept
ET 200M
Drive
PROFIBUS
G_ST80_XX_00431
Embedded IPC
Microbox PC
IPC427
Internet/
telephone network
G_ST80_XX_00430
Industrial
Ethernet
From the attenuation of the radiation, the foil thickness can be
determined exactly at each position by extensive mathematical
calculations, and deviations from the reference thickness can be
compensated.
The plant concept
Siemens ST 80 / ST PC · 2013
1/9
1
© Siemens AG 2013
Introduction
■ Overview (continued)
PC-based control of paint shops for plastic automotive parts
For reasons of quality assurance
and product liability, paint shop
manufacturers are obliged to
use a host computer for
archiving the process data of a
paint shop for flat parts, but this
quickly developed into a PCbased automation system with
control tasks.
The advantages of the solution with SIMATIC PC-based
Automation:
• Performance of the SIMATIC WinAC PC-based control.
• Coupling to Linux servers through an Industrial Ethernet fiberoptic network.
• Open and flexible for expansions.
• Possibility of integration into the existing automation concept.
• Archiving and backup of process data, as well as production
data acquisition.
Linux
Server
FOC Ethernet
Rack PC IPC847
WinAC RTX
WinCC flexible
PROFIBUS DP
HMI
Panel
ET 200M
S7-314
S7-314
HMI Panel
MPI DP
Frequency
converter
TP 177
HMI Panel
The plant concept
1/10
Siemens ST 80 / ST PC · 2013
VS 710
G_ST80_XX_00432
1
SIMATIC PC-based Automation
Innovative PC-based solution with safety for solar panel
production
For a new plant for the
production of solar panels, the
existing highly heterogeneous
concept is to be replaced by a
new, state-of-the-art automation
solution which can cover the
comprehensive demands in a
compact and integrated way.
There are increased performance and memory requirements due to the increased
complexity of the system. The
PLC should also be able to
provide the specified safety functions (emergency stop, access
protection to hazardous areas).
Various bus systems must be linked in plant 3. Also a customerspecific Windows application is to be used on the selected
systems and therefore the connection to a higher-level MES
system has to be implemented.
The system is designed for high throughput and three-shift
operation.
The advantages of the solution with SIMATIC PC-based
Automation:
• Very high performance and available memory with the
SIMATIC Modular Embedded Controller EC31-RTX F. In the
RTX F version (worldwide the first software PLC with safety
functionality), the EC31 offers full coverage of all safety
requirements in the plant. This system is integrated
seamlessly in Totally Integrated Automation and enables
effective, plant-wide engineering.
• Thanks to its openness (Open Development Kit), WinAC RTX
on the host SCADA industrial PC offers the possibility for
integrating a Windows customer application with very little
effort, and is thus used as a data concentrator (process
quality/diagnostic data), and communication with the host
MES system is also implemented in combination with WinCC
(SCADA).
• Industry-standard products from the SIMATIC range offer
maximum quality for 24/7 round the clock operation.
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
■ Overview (continued)
PC-based machine data acquisition optimizes the production
of farming machinery
Safe transfer at sea
For transferring persons at sea
to wind energy plants or oil
platforms, a Dutch company has
developed a six-legged
platform on hydraulic cylinders.
This platform is basically an
upside-down flight simulator,
and allows safe transfer from a
ship even in bad weather.
To introduce more efficient,
resource-saving and therefore
cost-effective production
processes in the factory, a
leading farming machinery
manufacturer has integrated a
central, plant-wide machine
data acquisition system using
Panel PCs. Due to the need for
retrofitting in the existing
environment, flexible and
space-saving installation of the
Panel PCs was paramount.
A SIMATIC S7 modular embedded controller (S7-mEC) with fast
I/O cards measures the movements of the ship and controls the
extending or retracting of the cylinders so that all movements are
compensated.
More than 200 fully enclosed SIMATIC HMI IPC477C PRO Panel
PCs for central machine data acquisition with communications
interfacing to the production machines and the production
planning computer. Mounting of the Panel PCs directly at the
machine without additional control boxes on stand-alone
columns.
The advantages of the solution with SIMATIC PC-based
Automation:
• Fault-tolerant SIMATIC S7-400H in redundant design for
general control tasks.
• Two lower-level SIMATIC S7 modular embedded controllers
which meet the requirements for high speeds, integration of
fast I/O cards, and a flexible, modular and rugged design.
• An integrated programming environment
with SIMATIC STEP 7.
• Automation products from Siemens comply
with the stringent requirements of the offshore sector.
The advantages of the solution with SIMATIC PC-based
Automation:
• Enhanced efficiency by optimizing the complete production
organization through a high degree of uniformity.
• Minimized use of resources
(less paper is required in production).
• Simple, low-cost retrofitting of the Panel PC directly in
production on a stand, without the installation of an additional
operator console.
Siemens ST 80 / ST PC · 2013
1/11
1
© Siemens AG 2013
Introduction
■ Overview (continued)
PC-based control in automotive test rigs
PC-based control in the semiconductor industry
Test rigs in the automotive
industry require trouble-free
operation and high quality.
A high-performance system is
required in the control,
processing, archiving and
visualization of measured data
which can also provide
openness and flexibility for
connection to different bus
systems and for the use of
software.
The advantages of the solution with SIMATIC PC-based
Automation:
• Flexible, easy-to-service and maintenance-friendly
system with Windows XP Embedded in conjunction with
SIMATIC WinAC.
• Reduction in integration overhead thanks to integral interfaces
such as PROFINET, PROFIBUS, Ethernet, CAN, and the flexibility when using modules for different bus systems,
e.g. PC/104.
• System availability concept ensures round-the-clock
operation and reduced downtime costs.
• Fan-free, temperature-resistant operation up to 50°C saves
additional cooling measures.
• High investment security through long-term availability of the
components.
Touch panel
In the semiconductor industry, high quality and fault-free
operation round-the-clock are decisive criteria. A high-performance system that guarantees fast and precise production of
the semiconductors is required for controlling the machines,
monitoring the production system, and processing the
production data.
High flexibility and openness are also required for connecting to
the production control system and machine engineering system.
The advantages of the solution with SIMATIC PC-based
Automation:
• Compact, rugged industrial PCs with powerful processors
and the latest technology enable high processing performance.
• Pre-installed systems save time and costs when integrated
into the overall system.
• WinCC ToolLink-EDA (equipment data acquisition) enables
diagnostics of process and machine data in real time.
• System availability concept with integral RAID1 functionality
and remote monitoring with SIMATIC PC DiagMonitor ensures
fault-free 24-hour operation.
• High investment security through long-term availability of the
components.
• International certification and worldwide support guarantee
global use.
Touch Panel
Host
Industrial Ethernet
Microbox
PC IPC427
Label printer
Industrial Ethernet
CAN-Bus
Barcode
reader
SIMATIC
IPC627
Vehicle
control unit
Machine
control
Visualization
PROFIBUS DP
Distributed
I/O devices
Sensors
The plant concept
1/12
Siemens ST 80 / ST PC · 2013
Distributed
I/O devices
Sensors
SIMATIC
IPC627
Industrial Ethernet
Port to
engineering
system
HUB
HMI
Panel
The plant concept
Measuring and
control
instruments
Sensors
G_ST80_XX_00434
RS232
USB
G_ST80_XX_00433
1
SIMATIC PC-based Automation
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
■ Overview (continued)
Track & trace line controller for tobacco industry
In order to comply with new
legal regulations, a track & trace
system in an existing plant has
been extended.
The requirement is to test
100 cartons per minute in
three-shift operation and to save
the data in an SQL database for
traceability reasons.
The automation system should
be characterized by high
ruggedness, but also offer the
openness required to connect
additional components such as printers and the Machine Vision
system.
The advantages of the solution with SIMATIC PC-based
Automation:
• Compact automation solution consisting of embedded
industrial PC Microbox PC IPC427, PLC with preinstalled and
ready-to-use software PLC WinAC RTX, and visualization with
WinCC flexible.
• Control of the entire track & trace system and interfacing to the
control system.
• Open solution with the help of the WinAC ODK (Open Development Kit) thanks to a link to an SQL database for managing
the serial numbers and other data.
• Additional openness and flexibility by connecting printers and
vision system.
Retrofit of a woodworking machine – safe!
In the past, machines and plants
for wood-working were
equipped with specially
developed, proprietary
controllers. Today, futureoriented standard components
are used for retrofit projects. The
customer decided in favor of
integrating standard automation
and safety technology in a
single unit with the SIMATIC
WinAC RTX F software controller
in a fan-free and maintenancefree IPC, the SIMATIC IPC427C
Microbox PC. PROFINET as an innovative fieldbus connects
distributed I/O, safety and operator panels quickly and easily.
The advantages of the solution with SIMATIC PC-based
Automation:
• The compact PC-based automation solution multiplies the
performance and precision of the plant.
• Implementation of PROFINET resulted in a series of additional
advantages such as the diagnostics capability.
• Integration of standard and fail-safe automation in a single unit
achieved component savings. The size of the cabinet was
reduced by 20 percent and the wiring by 50 percent. The
customer benefited from a high level of operating convenience and minimized machine downtimes.
www.siemens.com/reference-video-kuper
Siemens ST 80 / ST PC · 2013
1/13
1
© Siemens AG 2013
Introduction
■ Overview (continued)
Image processing with data backup
In image processing applications, high performance computers
are required due to the large volume of data to be processed.
The image data must be recorded, processed and saved
quickly. Frame grabber cards with a high data throughput, for
example, are used for recording image data. The interfaces for
the expansion cards must not become bottle-necks in this case.
To ensure continued problem-free processing of the acquired
data, you need a state-of-the-art system with up-to-date
processor and memory technology.
Lots of data is produced again during the subsequent data
backup. Thus the available storage medium must be fast and
fail-safe at the same time. An open system is required for
connecting to existing plants.
The advantages of the solution with SIMATIC PC-based
Automation:
• Rugged SIMATIC PC with state-of-the-art processor performance and the latest technology.
• Current interfaces such as PCI Express for applications with a
high data throughput rate, e.g. frame grabber cards for
recording image data.
• Visualization on up to two monitors with an optional,
high-performance graphics card.
• Onboard communication interfaces such as Ethernet and
PROFINET, e.g. for connecting to EPS systems or integration
in existing systems.
• International certifications and global support facilitate the
worldwide use of the image processing solution.
Control room
Server room
Rack PC IPC547
for visualization and
intermediate storage
of data
Flat Panel
Rack PC
IPC547 –
Server for data
management
Industrial Ethernet
Machine-level
Rack PC IPC847 with
PCIe frame grabber cards
Camera
.
.
.
The plant concept
1/14
Siemens ST 80 / ST PC · 2013
High-performance industrial PC for reliable control and
monitoring of wind power plants.
All Siemens turbines for offshore
wind power plants feature
special technical characteristics
that ensure long-term,
low-maintenance operation.
In contrast to sites on land,
offshore wind farms are not
always accessible to service
teams. The basic quality
requirements and standards for
all components used in terms of
absolute fail-safety and
reliability, are therefore
extremely high.
The SIMATIC Box PC of the 627 series that has been implemented matches the requirements of the solution provider all the
way down the line. The rugged industrial PC is designed for
24-hour continuous duty at ambient temperatures up to 55 °C.
For reliable operation, the Box PC is installed in a solid metal
enclosure that is resistant to shock and vibration and that
demonstrates a high degree of of electromagnetic compatibility
(EMC). For a high level of data security, the option of a mirror disk
system with two hard disks (RAID1) was selected. The RAID1
controller is already onboard, and does not occupy a PCI slot.
The rugged, reliable hardware with extremely compact dimensions in durable industrial design also stands up to the demands
of continuous operation in a harsh environment.
The advantages of the solution with SIMATIC PC-based
Automation:
• The mounting dimensions of Box PCs remain identical over
several device generations and mounting solutions can be
simply reused for the next generation.
• Furthermore, when a new device generation is used, any frontaccessible interfaces and function elements can be retained.
For example, the Siemens Wind division already utilized a
complete lifecycle of a Box PC generation and no adjustments
to a new hardware platform were required when the successor
product was introduced.
• Through compliance with international standards, such as CE
and UL, and worldwide service, the Box PC can be implemented round the globe.
G_ST80_XX_00436
1
SIMATIC PC-based Automation
2
© Siemens AG 2013
Operator panels
2/2
Introduction
2/6
2/6
Key Panels
SIMATIC HMI KP8/KP8F/32F
2/12
2/12
Basic Panels
Basic Panels – Standard
2/24
SIPLUS Basic Panels
2/26
2/26
Comfort Panels
Comfort Panels – Standard
2/40
SIPLUS Comfort Panels
2/44
2/45
2/52
2/57
2/69
2/70
2/73
2/74
2/74
2/75
Mobile Panels
SIMATIC Mobile Panel 177
SIMATIC Mobile Panel 277
SIMATIC Mobile Panel 277(F) IWLAN
System components for Mobile Panels
Terminal boxes
SIPLUS connection boxes
System components
Charging station
Transponder
2/76
2/77
2/79
System interfaces with WinCC
(TIA Portal)
SIMATIC S7
Controllers from other manufacturers
2/83
2/84
2/87
2/89
2/90
System interfaces with WinCC flexible
SIMATIC S7
SIMATIC S5
SIMATIC 505
PLCs from other manufacturers
2/96
2/96
2/97
2/98
2/99
2/100
2/101
2/104
2/104
2/105
2/109
2/110
2/112
2/116
2/118
2/122
2/124
2/130
2/135
2/137
SIMATIC HMI accessories
General HMI accessories
Industrial USB Hub 4
Touch pen and touch stylus
SIMATIC Mobile Panel accessories
Power supply unit
Additional accessories
SIMATIC HMI accessories
Connectors/converters/adapters
HMI connecting components
RS485 bus connector
IE FC RJ45 Plug 2 x 2
Connecting cables
Memory media
Service sets
Protective covers
Protective films
Fasteners
Labeling strips
Batteries
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Introduction
Introduction
■ Overview
Highest demands in terms
of performance and functionality?
Brilliant widescreen displays from 4"... 22"
Innovative commissioning and service concept
Energy management with PROFIenergy
2
Comfort
Panels
Basic
Panels
Low priced, pixel graphics
operator prompting?
Mobile
Panels
Key
Panels
Intuitive operation of
3"... 15"
Integrated HMI basis
functionality
Perfect interaction with
SIMATIC S7-1200
Maximum mobility and
flexibility?
Innovative operation
with and without cable
Robust for site-related local
operation
Integrated safety
concept
Eng
inee
Fast commissioning
Easy networking
Intuitive state detection
red w
ith Tota
lly
l
orta
P
n
o
i
t
Integrated Automa
G_ST80_XX_00501
Flexible expansion with keys –
or even safety functions?
A finely graded range of HMI devices is available for local
operator control and monitoring: From Key Panels and Basic
Panels to Comfort Panels and Mobile Panels. HMI devices with
all-round IP65/NEMA 4 protection for distributed configurations
are available for applications with especially high requirements
with regard to ruggedness.
Comfort Panels
Key Panels
The Comfort Panels are equipped with PROFINET/Ethernet as
well as PROFIBUS DP/MPI interfaces.
Key Panels (KP) are the innovative alternative to conventionally
wired operator keypads. Supplied pre-assembled and ready for
installation, the bus-compatible operator panels are the key to
drastically reducing wiring times when compared with conventional methods.
Basic Panels
Basic Panels offer basic HMI functionality for small machines
and applications. They are available in 3" and 4" sizes as a pure
Key Panel (KP), from 4" to 10" with touch screen and additional
keys (KTP), and as a pure Touch Panel (TP) in size 15". Variants
can be selected for connection to PROFINET/Ethernet or
PROFIBUS DP/MPI.
2/2
Siemens ST 80 / ST PC · 2013
Comfort Panels offer high-end functionality for demanding applications. They offer high-resolution widescreen displays in sizes
from 4" to 22", alternatively for touch screen operation (TP) or key
operation (KP). In size 4" also with touch screen and additional
keys (KTP).
Mobile Panels
The portable operator panels facilitate operator control and
monitoring at the actual scene of the event with direct access
and visual contact to the process. They provide simple and safe
reconnection during operation (Mobile Panel 177 and Mobile
Panel 277) or wireless freedom (Mobile Panel 277 (F) IWLAN)
and can therefore be used flexibly on a machine or system.
© Siemens AG 2013
Operator panels
Introduction
Introduction
■ Overview (continued)
Rugged and compact for use at machine level
Open for a wide variety of automation systems
With IP65/NEMA 4 degree of protection at the front, high EMC
and extreme vibration resistance, the SIMATIC HMI operator
panels are ideally suited for use at machine level in rough industrial environments. Thanks to their compact design with a
shallow mounting depth, the stationary HMI devices can be
fitted anywhere, even where only restricted space is available.
For distributed configurations, there are also devices available
with all-round IP65/NEMA 4 protection.
Despite being consistently incorporated into the SIMATIC world,
the Panels are nevertheless open for connection to PLCs from
many different vendors. The standard delivery includes a
comprehensive range of user-friendly drivers.
The extremely rugged and shock-proof enclosure with degree of
protection IP65 makes the Mobile Panels especially suitable for
industrial applications. Their low weight and ergonomic design
means that they are user-friendly and easy to operate.
One configuration software for everything
SIMATIC WinCC (TIA Portal) is a tool for the uniform configuration of all SIMATIC HMI Panels as well as PC-based systems.
Graded variants are available for every task. The software
permits simple and efficient configuration. Programming
experience is not required.
Once created, configurations can be reused within the family.
Component of Totally Integrated Automation
Siemens provides the complete modular system of matched
components for automation solutions from one source and —
with Totally Integrated Automation — one of the most globally
successful automation concepts. SIMATIC WinCC (TIA Portal) is
an integral component of this world. It offers crucial advantages.
Thanks to the triple uniformity in configuration/programming,
data management and communication, automation solution
engineering costs are significantly reduced.
Innovative operator control and monitoring
The SIMATIC HMI Panels facilitate innovative operator control
and monitoring combined with ruggedness, stability and
simplicity. On the Comfort Panels in particular, standard
hardware and software interfaces, e.g. the Multimedia Card/
SD Card, USB, Ethernet, PROFIBUS DP and Visual Basic
scripts, provide more flexibility and openness as well as access
to the office world.
Worldwide application
The SIMATIC HMI Panels are ideally equipped for global use.
Online language switching permits selection of up to
32 languages during operation simply by pressing a button.
The wide variety available also includes, for example, Asian
logographic languages (Chinese, Taiwanese, Korean,
Japanese) or Russian. The configuration interface of WinCC
(TIA Portal) including the online help and the complete
documentation is also multilingual. Up to 32 languages can be
used in one project. And all this is complemented by global
service and support from Siemens.
Siemens ST 80 / ST PC · 2013
2/3
2
© Siemens AG 2013
Operator panels
Introduction
Introduction
■ Overview (continued)
Configuration at a Glance
WinCC (TIA Portal) engineering software
Basic
Comfort
Advanced
Professional
KP300 Basic
•
•
•
•
KTP400 Basic mono PN
•
•
•
•
KTP400/KP400 Basic color PN
• 2)
• 2)
• 2)
• 2)
KTP600 Basic
•
•
•
•
KTP1000 Basic
•
•
•
•
TP1500 Basic
•
•
•
•
KTP400/KP400 Comfort
•
•
•
TP700/KP700 Comfort
•
•
•
TP900/KP900 Comfort
•
•
•
TP1200/KP1200 Comfort
•
•
•
TP1500/KP1500 Comfort
• 2)
• 2)
• 2)
TP1900 Comfort
• 2)
• 2)
• 2)
TP2200 Comfort
• 2)
• 2)
• 2)
Mobile Panel 177
•
•
•
Mobile Panel 277
•
•
•
Mobile Panel 277(F) IWLAN
• 3)
• 3)
• 3)
OP73
•
•
•
OP77A
•
•
•
OP77B
•
•
•
TP 177A
•
•
•
TP/OP 177B
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Basic Panels
2
Comfort Panels
Mobile Panels
Panels – 70 series
Panels – 170 series
Panels – 270 series
TP 277/OP 277
Multi Panels – 170 series
MP 177
Multi Panels – 270 series
MP 277
Multi Panels – 370 series
MP 377
WinAC MP
WinAC MP 177
• 1)
• 1)
• 1)
WinAC MP 277
•
1)
•
1)
• 1)
•
1)
•
1)
• 1)
WinAC MP 377
• Possible
1)
from WinCC (TIA Portal) V11 SP1
2)
from WinCC (TIA Portal) V11 SP2 Update 2
3)
from WinCC (TIA Portal) V11 SP2
2/4
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Introduction
Introduction
■ Overview (continued)
WinCC flexible engineering software
Micro
Compact
Standard
Advanced
KTP400 Basic mono PN
•5)
•5)
•5)
KTP600 Basic
•5)
•5)
•5)
KTP1000 Basic
•4)
•4)
•4)
4)
•
4)
•
•4)
• 1)
• 1)
• 1)
Basic Panels
TP1500 Basic
2
Mobile Panels
Mobile Panel 177
Mobile Panel 277
Mobile Panel 277(F) IWLAN
•
2) 4)
• 2) 4)
•
3)
• 3)
Micro Panels
OP 73micro
•
•
•
•
TP 177micro
•
•
•
•
OP 73
•
•
•
OP 77A/B
•
•
•
TP 177A
•
•
•
TP/OP 177B
• 1)
• 1)
• 1)
• 2)
• 2)
• 4)
• 4)
•
•
• 3)
• 3)
Panels – 70 series
Panels – 170 series
Panels – 270 series
TP 277/OP 277
Multi Panels – 170 series
MP 177
• 5)
Multi Panels – 270 series
MP 277
Multi Panels – 370 series
MP 377
WinAC MP
• 5)
• 5)
WinAC MP 277
• 5)
• 5)
WinAC MP 377
• 5)
• 5)
WinAC MP 177
• 5)
• Possible
1)
WinCC flexible 2005 or higher and TP 177B 4" with WinCC flexible 2008 and higher
2)
WinCC flexible 2005 SP1 and higher
3)
WinCC flexible 2007 and higher: Mobile Panel 277(F) IWLAN V1; WinCC flexible 2008 SP2 and higher: Mobile Panel 277(F) IWLAN V2
4)
WinCC flexible 2008 and higher
5)
WinCC flexible 2008 SP1 and higher
Siemens ST 80 / ST PC · 2013
2/5
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
■ Overview
2
SIMATIC HMI KP32F and HMI KP8
Empty front (similar to figure)
Empty front (similar to figure)
2/6
Siemens ST 80 / ST PC · 2013
SIMATIC HMI Key Panels
• Optimum operability thanks to large mechanical keys and
multi-colored LED backlighting (daylight readable)
• Over 60% time savings for wiring and installation (Plug&Play)
• More than 30% savings in material costs compared to conventional keypad operator panels
• 2 PROFINET ports (incl. switch) already integrated for setting
up line and ring topologies
• Freely configurable digital I/Os on the rear for connecting
key-operated switches, indicator lamps, etc.
• Connection of fail-safe emergency stop buttons or other
fail-safe signals with KP8F and KP32F (in SIL2 or SIL3)
• Functionally compatible with all standard PROFINET master
CPUs, also non-Siemens
• KP8 and empty front design, also optimized for installation in
IPC Extension Units in IP65
• Maximum flexibility due to parameterization
• Empty front design for standardized assembly of flexible
operator panels
• KP8 and empty front design, also optimized for installation in
IPC Extension Units in IP65
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
■ Technical specifications
6AV3688-3AY36-0AX0
6AV3688-3AF37-0AX0
6AV3688-3EH47-0AX0
6AV3688-3XY38-3AX0
SIMATIC HMI KP8 PN
SIMATIC HMI KP8F PN
SIMATIC HMI KP32F PN
SIMATIC HMI
design empty front
Yes
Yes
Yes
No
Yes; Automatically when
switching on
Yes; Automatically when
switching on
Yes; Automatically when
switching on
No
Yes
Yes
Yes
No
8
8
32
0
8
5; Red, green, blue, white,
yellow
8
32
5; Red, green, blue, white,
yellow
32
0
0
• Number/keys
8
5; Red, green, blue, white,
yellow
8
Installation type/mounting
Rack mounting possible
Control elements
With parameterizable keys
With key and signal lamp test
Keyboard fonts
• freely inscribable membrane keys
• Short stroke keys
- Number of short-stroke keys
Expansions for operator control
of the process
• Number/LEDs
• Number of color modes for LED
2
0
No
No
No
No
Design/front/fastening
Yes; Compatible with
extension unit dimensions
Yes; Compatible with
extension unit dimensions
Yes
Yes; Compatible with
extension unit dimensions
Mounting rail installation possible
No
No
No
No
Wall mounting/direct mounting possible
No
No
No
No
Mounting in portrait format possible
Yes
Yes
Yes
Yes
Mounting in landscape format
possible
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0
0
0
5; Max. 5 possible
Supply voltage
Type of supply voltage
DC
DC
DC
external
Rated voltage/DC
24 V
24 V
24 V
permissible range, lower limit (DC)
20.4 V
20.4 V
20.4 V
permissible range, upper limit (DC)
28.8 V
28.8 V
28.8 V
Type of output
LED colors
• Red
• Yellow
• Green
• white
• blue
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
8; Max. 8 inputs and
outputs (total)
8; Max. 32 inputs and
outputs (total)
32; Max. 32 inputs and
outputs (total)
0
8; Max. 8 inputs and outputs (total)
8; Max. 8 inputs and outputs (total)
16; Max. 32 inputs and
outputs (total)
0
Mounting technology
• Clamp terminals
Number of slots for command
devices and signaling units
Digital inputs
Number/binary inputs
Digital outputs
Number/binary outputs
Load "resistive"
100 mA
100 mA
100 mA
Voltage (DC)
24 V; Non-isolated
24 V; Non-isolated
24 V; Non-isolated
Number of digital outputs
• Output current (per output) max.
• Total current (per group), max.
• Short-circuit protection
100 mA
800 mA
Yes
100 mA
800 mA
Yes
100 mA
800 mA
Yes
No
Siemens ST 80 / ST PC · 2013
2/7
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
■ Technical specifications (continued)
2
6AV3688-3AY36-0AX0
6AV3688-3AF37-0AX0
6AV3688-3EH47-0AX0
6AV3688-3XY38-3AX0
SIMATIC HMI KP8 PN
SIMATIC HMI KP8F PN
SIMATIC HMI KP32F PN
SIMATIC HMI
design empty front
2; Incl. switch
2; Incl. switch
2; Incl. switch
0
2; For the construction of
lines and rings without
external switch
2; Per port
2; Per port
2; For the construction of
lines and rings without
external switch
2; Per port
2; Per port
2; For the construction of
lines and rings without
external switch
2; Per port
2; Per port
0
Protocols
PROFINET
Yes; Incl. shared device
Yes; Incl. shared device
Yes; Incl. shared device
No
Supports protocol for PROFINET IO
Yes
Yes
Yes
No
IRT supported
Yes
Yes
Yes
No
MRP supported
Yes
Yes
Yes
No
PROFINET CBA
No
No
No
No
Supports protocol for PROFIsafe
No
Yes; Mode V2.0; 2 inputs
can be used
Yes; Mode V2.0; 4 inputs
can be used
No
PROFIBUS
No
No
No
No
Test commissioning functions
Illuminant test
Yes; During switch on
Yes; During switch on
Yes; During switch on
No
Pushbutton and lamp test
Yes; During switch on
Yes; During switch on
Yes; During switch on
No
Yes; Group 1, measured
at a distance of 10 m
No
Yes; Group 1, measured
at a distance of 10 m
No
Yes; Group 1, measured
at a distance of 10 m
No
No
Degree and class of protection
Type of protection
IP20
IP20
IP20
IP20
IP (at the front)
IP65
IP65
IP65
IP65
Enclosure type 4x at the front
Yes; Incl. NEMA12
Yes; Incl. NEMA12
Yes; Incl. NEMA12
No
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
KC approval
Yes
Yes
Yes
No
cULus
Yes
Yes
Yes
No
C-TICK
Yes
Yes
Yes
No
GL
No
No
No
No
ABS
No
No
No
No
BV
No
No
No
No
DNV
No
No
No
No
LRS
No
No
No
No
Class NK
No
No
No
No
PRS
No
No
No
No
Suitable for safety functions
No
Yes
Yes
Yes; e.g. installation of
emergency stop
Yes
Yes
No
Yes
Yes
Yes
No
Yes
No; On request
No; On request
No
Yes
No
No
No
No
Yes
Yes; Available soon
Yes
No
Interfaces
Supports protocol for PROFINET IO
• Number of PROFINET interfaces
Industrial Ethernet
• Number of industrial Ethernet
interfaces
• Industrial Ethernet status LED
• Number of ports of the integrated
switch
EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A)
• Emission of radio interference
acc. to EN 55 011 (limit class B)
Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 1
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
2/8
Siemens ST 80 / ST PC · 2013
0
0
No
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
■ Technical specifications (continued)
6AV3688-3AY36-0AX0
6AV3688-3AF37-0AX0
6AV3688-3EH47-0AX0
6AV3688-3XY38-3AX0
SIMATIC HMI KP8 PN
SIMATIC HMI KP8F PN
SIMATIC HMI KP32F PN
SIMATIC HMI
design empty front
vertical
vertical
vertical
Any
30°; To the front/rear
30°; To the front/rear
30°; To the front/rear
180°; To the front/rear
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
0 °C
0 °C
0 °C
0 °C
55 °C
55 °C
55 °C
55 °C
0 °C
0 °C
0 °C
0 °C
45 °C
45 °C
45 °C
45 °C
0 °C
0 °C
0 °C
0 °C
45 °C
45 °C
45 °C
45 °C
0 °C
0 °C
0 °C
0 °C
45 °C
45 °C
45 °C
45 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
Relative humidity
• max. relative humidity
95 %
95 %
95 %
95 %
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No
Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No
Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No
Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No
Ambient conditions
Mounting position
maximum permissible angle of
inclination without external ventilation
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
• Operation (max. tilt angle)
- at maximum tilt angle/
minimum
- at maximum tilt angle/
maximum
• Operation (vertical installation,
portrait format)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
• Operation (max. tilt angle,
portrait format)
- at maximum tilt angle/
minimum
- at maximum tilt angle/
maximum
Configuration
Configuration software
• STEP 7 Basic (TIA Portal)
• STEP 7 Professional
(TIA Portal)
Functionality under
WinCC (TIA Portal)
Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SINUMERIK
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)
Siemens ST 80 / ST PC · 2013
2/9
2
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
■ Technical specifications (continued)
2
6AV3688-3AY36-0AX0
6AV3688-3AF37-0AX0
6AV3688-3EH47-0AX0
6AV3688-3XY38-3AX0
SIMATIC HMI KP8 PN
SIMATIC HMI KP8F PN
SIMATIC HMI KP32F PN
SIMATIC HMI
design empty front
Yes
No
Yes
No
No
Yes
No
Yes
1500000
1500000
1500000
Dimensions
Width of the housing front
98 mm
98 mm
295 mm
98 mm
Height of housing front
155 mm
155 mm
155 mm
155 mm
68 mm; Max. thickness of
mounting plate 2-6 mm
129 mm
68 mm; Max. thickness of
mounting plate 2-6 mm
129 mm
277 mm; Max. thickness of
mounting plate 2-6 mm
137 mm
68 mm; Max. thickness of
mounting plate 2-6 mm
129 mm
49 mm; Incl. angled
SIMATIC Ethernet
connector
49 mm; Incl. angled
SIMATIC Ethernet
connector
69 mm; Incl. angled
SIMATIC Ethernet
connector
49 mm
270 g
280 g
1 220 g
240 g
Mechanics/material
Type of housing (front)
• Plastic
• Aluminum
Lifetime, typ.
• Short-stroke keys
(in switching cycles)
Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height
Depth/installation dimension
Weight
Weight without packaging
■ Ordering data
SIMATIC HMI KP8 PN
Order No.
6AV3688-3AY36-0AX0
Key Panel, 8 short-stroke keys with
multicolored LEDs, PROFINET interfaces, 2 x parameterizable with
STEP 7 V5.5 or higher
SIMATIC HMI KP8F PN
6AV3688-3AF37-0AX0
Key Panel, 8 short-stroke keys with
multicolored LEDs, PROFINET interfaces with PROFIsafe, parameterizable with STEP 7 V5.5 or higher;
4 additional fail-safe inputs. Can be
used as 2 x SIL 2 or 1 x SIL 3
SIMATIC HMI KP32F PN
6AV3688-3EH47-0AX0
Key Panel, 32 short-stroke keys with
multicolored LEDs, PROFINET interfaces with PROFIsafe, parameterizable with STEP 7 V5.5 or higher;
including 8 fail-safe inputs. Can be
used as 4 x SIL 2 or 2 x SIL 3
Empty front design
6AV3688-3XY38-3AX0
for standard 22.5 mm operator
controls, same mounting
dimensions as KP8
Demo case
A5E31477788
SIMATIC HMI Key Panel – low-cost
demo and experiment case
• Includes:
- 1x case
- 1x KP8 PN
- 1x CPU1211C
- 1x stand, permanently wired,
including program
• Power supply possible with a
standard laptop mains adapter
(not included in scope of supply)
Only by fax to
Siemens AG,
Mr. Michael Christ
Industry Sector,
I IA CE SE MF RS FDS
Wuerzburger Str. 121,
90766 Fuerth, Germany
Tel.: +49 911 750-4128
Fax: +49 911 750-2411
2/10
Siemens ST 80 / ST PC · 2013
Order No.
Documentation
You can find the manual for
the Key Panels on the Internet at:
http://support.automation.siemens.com/WW/view/en/56652789
Accessories
See SIMATIC HMI accessories,
from page 2/96
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
■ Dimensional drawings
■ More information
All dimensions in mm. For installation cutout, see technical
specifications.
Additional information is available on the Internet at:
http://www.siemens.com/simatic-key-panels
13.7
Note:
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
127.7
155
Demo case
Can be ordered by fax:
Siemens AG, Mr. Michael Christ
Industry Sector, I IA CE SE MF RS FDS
Wuerzburger Str. 121, 90766 Fuerth, Germany
Phone: +49 911 750-4128
Fax: +49 911 750-2411
38
98
6
48.8
16.2
G_ST80_XX_00442
67.5
275
10
10
2 37
6
G_ST80_XX_00499
295
135
155
SIMATIC HMI Key Panel KP8; installation dimensions also valid for empty
front design
SIMATIC HMI Key Panel KP32F
Siemens ST 80 / ST PC · 2013
2/11
2
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Overview
• Ideal entry-level series from 3" to 15" for operating and
monitoring compact machines and systems
• Clear process representation thanks to use of pixel-graphics
displays
• Intuitive operation using Touch and tactile function keys
• Equipped with all the necessary basic functions such as alarm
logging, recipe management, plots, vector graphics, and
language switching
• Simple connection to the controller via integral Ethernet
interface or separate version with RS 485/422
• Faster commissioning thanks to integrated diagnostics viewer
and IP setting for SIMATIC S7-1200 and S7-1500 PLCs
2
■ Technical specifications
6AV6647-0AA11-3AX0
6AV6647-0AK11-3AX0
6AV6647-0AB11-3AX0
6AV6647-0AC11-3AX0
SIMATIC HMI KTP400
Basic mono PN
SIMATIC HMI KTP400
Basic color PN
SIMATIC HMI KTP600
Basic mono PN
SIMATIC HMI KTP600
Basic color DP
Display
Design of display
STN
TFT
STN
TFT
Screen diagonal
3.8 in
4.3 in
5.7 in
5.7 in
Number of colors
4; Grayscales
256
4; Grayscales
256
Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution
320
240
480
272
320
240
320
240
Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight
30 000 h
No
50 000 h
No
50 000 h
No
50 000 h
No
Control elements
Keyboard fonts
• Number of function keys
4
4
6
6
Touch operation
• Design as touch screen
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Supply voltage
Type of supply voltage
DC
DC
DC
DC
Rated voltage/DC
24 V
24 V
24 V
24 V
Memory
Usable memory for user data
1 Mbyte
1 Mbyte
1 Mbyte
1 Mbyte
Type of output
Acoustics
• Buzzer
Yes
Yes
Yes
Yes
Time of day
Clock
• Software clock
• Battery-backed
• Synchronizable
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Interfaces
Number of RS 485 interfaces
0
0
0
1
Number of USB interfaces
0
0
0
0
Number of SD card slots
0
0
0
0
Industrial Ethernet
• Number of industrial Ethernet
interfaces
1
1
1
0
Installation type/mounting
Mounting in portrait format
possible
2/12
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Technical specifications (continued)
6AV6647-0AA11-3AX0
6AV6647-0AK11-3AX0
6AV6647-0AB11-3AX0
6AV6647-0AC11-3AX0
SIMATIC HMI KTP400
Basic mono PN
SIMATIC HMI KTP400
Basic color PN
SIMATIC HMI KTP600
Basic mono PN
SIMATIC HMI KTP600
Basic color DP
Protocols
PROFINET
Yes
Yes
Yes
No
PROFIBUS
No
No
No
Yes
MPI
No
No
No
Yes
Degree and class of
protection
Type of protection
IP20
IP20
IP20
IP20
IP (at the front)
IP65
IP65
IP65
IP65
Enclosure type 4x at the front
Yes
Yes
Yes
Yes
Standards, approvals,
certificates
CE
Yes
Yes
Yes
Yes
cULus
Yes
Yes
Yes
Yes
GL
Yes
Yes
Yes
Yes
ABS
Yes
Yes
Yes
Yes
BV
Yes
Yes
Yes
Yes
DNV
Yes
Yes
Yes
Yes
LRS
Yes
Yes
Yes
Yes
Class NK
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
0 °C
0 °C
0 °C
0 °C
50 °C
50 °C
50 °C
50 °C
90 %
90 %
90 %
90 %
Yes; via integrated WinCC
Basic (TIA Portal)
Yes
Yes
Yes; via integrated WinCC
Basic (TIA Portal)
No
Yes
Yes; via integrated WinCC
Basic (TIA Portal)
Yes
Yes
Yes; via integrated WinCC
Basic (TIA Portal)
Yes
Yes
5
5
5
5
No
Yes
No
Yes
No
Yes
No
Yes
200
15
200
15
200
15
200
15
256
Yes
Yes
256
Yes
Yes
256
Yes
Yes
256
Yes
Yes
5
40 kbyte
No
5
40 kbyte
No
5
40 kbyte
No
Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical
installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Relative humidity
• max. relative humidity
Configuration
Configuration software
• STEP 7 Basic (TIA Portal)
• WinCC flexible Compact
• WinCC Basic (TIA Portal)
Languages
Online languages
• Number of online/runtime
languages
Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled
• task-controlled
With alarm logging system (incl.
buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive
Recipes
• Number of recipes
5
• Size of internal recipe memory 40 kbyte
• Recipe memory expandable
No
Siemens ST 80 / ST PC · 2013
2
2/13
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Technical specifications (continued)
2
6AV6647-0AA11-3AX0
6AV6647-0AK11-3AX0
6AV6647-0AB11-3AX0
6AV6647-0AC11-3AX0
SIMATIC HMI KTP400
Basic mono PN
SIMATIC HMI KTP400
Basic color PN
SIMATIC HMI KTP600
Basic mono PN
SIMATIC HMI KTP600
Basic color DP
250
500
500
500
30
30
30
30
Images
• Number of configurable
images
50
50
50
50
Archiving
• Number of archives per
device
0
0
0
0
Security
• Number of user groups
• Number of users
50
50
50
50
50
50
50
50
Transfer (upload/download)
• MPI/PROFIBUS DP
• Ethernet
No
Yes
No
Yes
No
Yes
Yes
No
Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes
I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Mechanics/material
Type of housing (front)
• Plastic
Yes
Yes
Yes
Yes
Dimensions
Width of the housing front
140 mm
140 mm
214 mm
214 mm
Height of housing front
116 mm
116 mm
158 mm
158 mm
Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height
123 mm
99 mm
123 mm
99 mm
197 mm
141 mm
197 mm
141 mm
Weight
Weight without packaging
0.32 kg
0.34 kg
1.07 kg
1.07 kg
Variables
• Number of variables per
device
• Number of variables per
screen
2/14
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Technical specifications (continued)
6AV6647-0AD11-3AX0
6AV6647-0AE11-3AX0
6AV6647-0AF11-3AX0
SIMATIC HMI KTP600
Basic color PN
SIMATIC HMI KTP1000
Basic color DP
SIMATIC HMI KTP1000
Basic color PN
Display
Design of display
TFT
TFT
TFT
Screen diagonal
5.7 in
10.4 in
10.4 in
Number of colors
256
256
256
Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution
320
240
640
480
640
480
Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight
50 000 h
No
50 000 h
No
50 000 h
No
Control elements
Keyboard fonts
• Number of function keys
6
8
8
Touch operation
• Design as touch screen
Yes
Yes
Yes
Installation type/mounting
Mounting in portrait format possible
Yes
No
No
Supply voltage
Type of supply voltage
DC
DC
DC
Rated voltage/DC
24 V
24 V
24 V
Memory
Usable memory for user data
1 Mbyte
2 Mbyte
2 Mbyte
Type of output
Acoustics
• Buzzer
Yes
Yes
Yes
Time of day
Clock
• Software clock
• Battery-backed
• Synchronizable
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Interfaces
Number of RS 485 interfaces
0
1
0
Number of USB interfaces
0
0
0
Number of SD card slots
0
0
0
Industrial Ethernet
• Number of industrial Ethernet
interfaces
1
0
1
Protocols
PROFINET
Yes
No
Yes
PROFIBUS
No
Yes
No
MPI
No
Yes
No
Degree and class of protection
Type of protection
IP20
IP20
IP20
IP (at the front)
IP65
IP65
IP65
Enclosure type 4x at the front
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
cULus
Yes
Yes
Yes
GL
Yes
Yes
Yes
ABS
Yes
Yes
Yes
BV
Yes
Yes
Yes
DNV
Yes
Yes
Yes
LRS
Yes
Yes
Yes
Class NK
Yes
Yes
Yes
Siemens ST 80 / ST PC · 2013
2
2/15
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Technical specifications (continued)
2
6AV6647-0AD11-3AX0
6AV6647-0AE11-3AX0
6AV6647-0AF11-3AX0
SIMATIC HMI KTP600
Basic color PN
SIMATIC HMI KTP1000
Basic color DP
SIMATIC HMI KTP1000
Basic color PN
No
No
No
No
No
No
No
No
No
No
No
No
0 °C
0 °C
0 °C
50 °C
50 °C
50 °C
90 %
90 %
90 %
• WinCC flexible Compact
• WinCC Basic (TIA Portal)
Yes; via integrated WinCC Basic
(TIA Portal)
Yes
Yes
Yes; via integrated WinCC Basic
(TIA Portal)
Yes
Yes
Yes; via integrated WinCC Basic
(TIA Portal)
Yes
Yes
Languages
Online languages
• Number of online/runtime languages
5
5
5
Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled
• task-controlled
No
Yes
No
Yes
No
Yes
200
15
200
15
200
15
256
Yes
Yes
256
Yes
Yes
256
Yes
Yes
Recipes
• Number of recipes
• Size of internal recipe memory
• Recipe memory expandable
5
40 kbyte
No
5
40 kbyte
No
5
40 kbyte
No
Variables
• Number of variables per device
• Number of variables per screen
500
30
500
30
500
30
Images
• Number of configurable images
50
50
50
Archiving
• Number of archives per device
0
0
0
Security
• Number of user groups
• Number of users
50
50
50
50
50
50
Transfer (upload/download)
• MPI/PROFIBUS DP
• Ethernet
No
Yes
Yes
No
No
Yes
Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2, Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
Relative humidity
• max. relative humidity
Configuration
Configuration software
• STEP 7 Basic (TIA Portal)
With alarm logging system
(incl. buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive
2/16
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Technical specifications (continued)
6AV6647-0AD11-3AX0
6AV6647-0AE11-3AX0
6AV6647-0AF11-3AX0
SIMATIC HMI KTP600
Basic color PN
SIMATIC HMI KTP1000
Basic color DP
SIMATIC HMI KTP1000
Basic color PN
Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
Yes
I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
No
No
No
No
No
No
No
No
No
No
No
No
Mechanics/material
Type of housing (front)
• Plastic
Yes
Yes
Yes
Dimensions
Width of the housing front
214 mm
335 mm
335 mm
Height of housing front
158 mm
275 mm
275 mm
Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height
197 mm
141 mm
310 mm
248 mm
310 mm
248 mm
Weight
Weight without packaging
1.07 kg
2.65 kg
2.65 kg
Siemens ST 80 / ST PC · 2013
2
2/17
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Technical specifications (continued)
2
6AV6647-0AH11-3AX0
6AV6647-0AJ11-3AX0
6AV6647-0AG11-3AX0
SIMATIC HMI KP300
Basic mono PN
SIMATIC HMI KP400
Basic color PN
SIMATIC HMI TP1500
Basic color PN
Display
Design of display
FSTN
TFT
TFT
Screen diagonal
3.6 in
4.3 in
15 in
Number of colors
4; Backlit display only
(white, red, green, yellow)
256
256
Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution
240
80
480
272
1 024
768
Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight
50 000 h
No
50 000 h
No
50 000 h
No
Control elements
Keyboard fonts
• Number of function keys
10
8
0
Touch operation
• Design as touch screen
No
No
Yes
Installation type/mounting
Mounting in portrait format possible
No
No
No
Supply voltage
Type of supply voltage
DC
DC
DC
Rated voltage/DC
24 V
24 V
24 V
Memory
Usable memory for user data
1 Mbyte
1 Mbyte
2 Mbyte
Type of output
Acoustics
• Buzzer
No
No
Yes
Time of day
Clock
• Software clock
• Battery-backed
• Synchronizable
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Interfaces
Number of RS 485 interfaces
0
0
0
Number of USB interfaces
0
0
0
Number of SD card slots
0
0
0
Industrial Ethernet
• Number of industrial Ethernet
interfaces
1
1
1
Protocols
PROFINET
Yes
Yes
Yes
PROFIBUS
No
No
No
MPI
No
No
No
Degree and class of protection
Type of protection
IP20
IP20
IP20
IP (at the front)
IP65
IP65
IP65
Enclosure type 4x at the front
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
cULus
Yes
Yes
Yes
GL
Yes
No
No
ABS
Yes
No
No
BV
Yes
No
No
DNV
Yes
No
No
LRS
Yes
No
No
Class NK
Yes
No
No
2/18
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Technical specifications (continued)
6AV6647-0AH11-3AX0
6AV6647-0AJ11-3AX0
6AV6647-0AG11-3AX0
SIMATIC HMI KP300
Basic mono PN
SIMATIC HMI KP400
Basic color PN
SIMATIC HMI TP1500
Basic color PN
No
No
Yes
No
No
No
No
No
No
No
No
No
0 °C
0 °C
0 °C
50 °C
50 °C
50 °C
90 %
90 %
90 %
• WinCC flexible Compact
• WinCC Basic (TIA Portal)
Yes; via integrated WinCC Basic
(TIA Portal)
No
Yes
Yes; via integrated WinCC Basic
(TIA Portal)
No
Yes
Yes; via integrated WinCC Basic
(TIA Portal)
Yes
Yes
Languages
Online languages
• Number of online/runtime languages
5
5
5
Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled
• task-controlled
No
Yes
No
Yes
No
Yes
200
15
200
15
200
15
256
Yes
Yes
256
Yes
Yes
256
Yes
Yes
Recipes
• Number of recipes
• Size of internal recipe memory
• Recipe memory expandable
5
40 kbyte
No
5
40 kbyte
No
5
40 kbyte
No
Variables
• Number of variables per device
• Number of variables per screen
250
30
500
30
500
30
Images
• Number of configurable images
50
50
50
Archiving
• Number of archives per device
0
0
0
Security
• Number of user groups
• Number of users
50
50
50
50
50
50
Transfer (upload/download)
• MPI/PROFIBUS DP
• Ethernet
No
Yes
No
Yes
No
Yes
Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2, Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
Relative humidity
• max. relative humidity
Configuration
Configuration software
• STEP 7 Basic (TIA Portal)
With alarm logging system
(incl. buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive
Siemens ST 80 / ST PC · 2013
2
2/19
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Technical specifications (continued)
2
6AV6647-0AH11-3AX0
6AV6647-0AJ11-3AX0
6AV6647-0AG11-3AX0
SIMATIC HMI KP300
Basic mono PN
SIMATIC HMI KP400
Basic color PN
SIMATIC HMI TP1500
Basic color PN
Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
Yes
I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
No
No
No
No
No
No
No
No
No
No
No
No
Mechanics/material
Type of housing (front)
• Plastic
Yes
Yes
Yes
Dimensions
Width of the housing front
165 mm
162 mm
400 mm
Height of housing front
97 mm
189 mm
310 mm
Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height
149 mm
82 mm
135 mm
171 mm
367 mm
289 mm
Weight
Weight without packaging
0.25 kg
0.51 kg
4.2 kg
2/20
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Ordering data
Order No.
SIMATIC HMI Basic Panels,
Key and Touch
Order No.
Starter kits
6AV6647-0AA11-3AX0
Starter kit SIMATIC S7-1200 +
KP300 Basic mono PN
6AV6651-7HA01-3AA3
SIMATIC HMI KTP400
Basic mono PN
6AV6647-0AK11-3AX0
Starter kit SIMATIC S7-1200 +
KTP400 Basic color PN
6AV6651-7KA01-3AA3
SIMATIC HMI KTP400
Basic color PN
6AV6647-0AB11-3AX0
Starter kit SIMATIC S7-1200 +
KTP600 Basic color PN
6AV6651-7DA01-3AA3
SIMATIC HMI KTP600
Basic mono PN
SIMATIC HMI KTP600
Basic color DP
6AV6647-0AC11-3AX0
SIMATIC HMI KTP600
Basic color PN
6AV6647-0AD11-3AX0
SIMATIC HMI KTP1000
Basic color DP
6AV6647-0AE11-3AX0
SIMATIC HMI KTP1000
Basic color PN
6AV6647-0AF11-3AX0
SIMATIC HMI Basic Panels, Key
SIMATIC HMI KP300
Basic mono PN
6AV6647-0AH11-3AX0
SIMATIC HMI KP400
Basic color PN
6AV6647-0AJ11-3AX0
SIMATIC HMI Basic Panels, Touch
SIMATIC HMI TP1500
Basic color PN
6AV6647-0AG11-3AX0
2
Starter kits with an S7-1200
consist of:
• the respective SIMATIC HMI
Basic Panel
- SIMATIC HMI KP300
Basic mono PN
- SIMATIC HMI KTP400
Basic color PN
- SIMATIC HMI KTP600
Basic color PN
• SIMATIC S7-1200 CPU 1212C
AC/DC/Rly
• SIMATIC S7-1200
Simulator Module SIM 1274
• SIMATIC STEP 7 BASIC CD
• SIMATIC S7-1200 HMI
Manual Collection CD
• Ethernet CAT5 cable, 2 m
LOGO! starter kit + KP300
Basic mono PN
6AV2132-0HA00-0AA0
LOGO! starter kit + KTP400
Basic color PN
6AV2132-0KA00-0AA0
Starter kits with a LOGO! consist of:
• the respective SIMATIC HMI
Basic Panel
- SIMATIC HMI KP300
Basic mono PN
- SIMATIC HMI KTP400
Basic color PN
• LOGO! 12/24 RCE
• LOGO! POWER 24 V 1.3 A
• LOGO! SOFT COMFORT V7
• WINCC BASIC (TIA Portal)
• Ethernet CAT5 cable, 2 m
Documentation
You can find the manual for the
Basic Panels on the Internet at:
http://support.automation.siemens.com
Accessories
See HMI accessories,
from page 2/96
Siemens ST 80 / ST PC · 2013
2/21
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical specifications.
148
165
98
116
2
28.9
KTP400 Basic color PN
190
122
170
KP300 Basic
122
G_ST80_XX_00517
6.2
33.5
39.7
G_ST80_XX_00462
81
96.6
141
116
98
SIMATIC PANEL
162
33.5
KTP400 Basic mono PN
2/22
Siemens ST 80 / ST PC · 2013
40
6.2
G_ST80_XX_00355
140
KP400 Basic
G_ST80_XX_00516
39.7
134
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
■ Dimensional drawings (continued)
196
S
366
2
SIMATIC PANEL
SIMATIC PANEL
310
288
140
158
S
G_ST80_XX_00356
6.2
400
59.9
6.2
G_ST80_XX_00358
44
214
TP1500 Basic
KTP600 Basic
309
S
60.2
6.2
335
G_ST80_XX_00357
247
275
SIMATIC PANEL
KTP1000 Basic
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-basic-panels
Note
Do you require a specific modification to or supplement for the
products described here? Look under "Customized products".
We provide information there about additional and generally
available sector products, and about the customer-specific
modification and adaptation options.
Siemens ST 80 / ST PC · 2013
2/23
© Siemens AG 2013
Operator panels
SIPLUS Basic Panels
SIPLUS Basic Panels
■ Overview
• Ideal entry-level series of 3.8 inches to 15 inches for operating
and monitoring compact machines and systems
• Clear process representation through the use of full-graphic
displays
• Intuitive operation via touch and tactile function keys
• Equipped with all the necessary basic functions such as
reporting, recipe management, curve representation, vector
graphics, and language selection
• Easy connection to the controller via integrated Ethernet
interface or a separate version with RS485/422
2
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific information was added.
SIPLUS HMI
KTP300 BASIC
MONO PN
SIPLUS HMI
KTP400 BASIC
MONO PN
SIPLUS HMI
KTP600 BASIC
COLOR PN
SIPLUS HMI
KTP1000 BASIC
COLOR DP
SIPLUS HMI
KTP1000 BASIC
COLOR PN
SIPLUS HMI
TP1500 BASIC
COLOR PN
Order number
6AG16470AH11-2AX0
6AG16470AA11-2AX0
6AG16470AD11-2AX0
6AG1647-0AE11- 6AG1647-0AF114AX0
4AX0
6AG16470AG11-4AX0
Order No. based on
6AV6647-0AH113AX0
6AV6647-0AA113AX0
6AV6647-0AD113AX0
6AV6647-0AE113AX0
6AV6647-0AF113AX0
6AV6647-0AG113AX0
Ambient temperature range
-25 ... +60 °C
-10 ... +60 °C
-25 ... +60 °C
0 ... +50 °C
0 ... +50 °C
0 ... +50 °C
Conformal coating
Coating of the printed circuit boards and the electronic components
Technical data
The technical data of the standard product applies except for the ambient conditions.
Ambient conditions
Relative humidity
100 %, condensation/frost permissible. No commissioning if condensation present.
Biologically active substances,
compliance with EN 60721-3-3
Class 3B2 mold and fungal spores (excluding fauna).
The supplied plug covers must remain in place over the unused interfaces during operation!
Chemically active substances,
compliance with EN 60721-3-3
Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3).
The supplied plug covers must remain in place over the unused interfaces during operation!
Mechanically active substances,
compliance with EN 60721-3-3
Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation!
Air pressure
(depending on the highest positive
temperature range specified)
1 080 ... 795 hPa (-1 000 ... +2 000 m)
see ambient temperature range
795 ... 658 hPa (+2000 ... +3500 m)
derating 10 K658 ... 540 hPa
(+3 500 ... +5 000 m)
derating 20 K
For technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-extreme
2/24
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIPLUS Basic Panels
SIPLUS Basic Panels
■ Ordering data
SIPLUS HMI KTP300
Basic mono PN
Order No.
6AG1647-0AH11-2AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature -25 ... +60 °C
SIPLUS HMI KTP400
Basic mono PN
For areas with extreme medial
exposure (conformal coating);
ambient temperature -25 ... +60 °C
6AG1647-0AE11-4AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
6AG1647-0AA11-2AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature -10 ... +60 °C
SIPLUS HMI KTP600
Basic color PN
Order No.
SIPLUS HMI KTP1000
Basic Color DP
SIPLUS HMI KTP1000
Basic Color PN
6AG1647-0AF11-4AX0
2
For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
6AG1647-0AD11-2AX0
SIPLUS HMI TP1500
Basic Color PN
6AG1647-0AG11-4AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
Accessories
See SIMATIC Basic Panels,
from page 2/12
Additional information is available in the Internet under:
http://www.siemens.com/simatic-basic-panels
Note
Do you require a specific modification to or supplement for the
products described here? Look under "Customized products".
We provide information there about additional and generally
available sector products, and about the customer-specific
modification and adaptation options.
Siemens ST 80 / ST PC · 2013
2/25
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Overview
2
• Excellent HMI functionality for demanding applications
• Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and 22"
diagonals (all 16 million colors) with up to 40% more visualization area as compared to the predecessor devices
• Integrated high-end functionality with archives, scripts,
PDF/Word/Excel viewer, Internet Explorer, Media Player and
Web Server
• Dimmable displays from 0 to 100% via PROFIenergy, via the
HMI project or via a controller
• Modern industrial design, cast aluminum fronts for 7" upwards
• Upright installation for all touch devices
• Optimal selection option: seven touch and five key versions
are available
• Data security in the event of a power failure for the device and
for the SIMATIC HMI Memory Card
• Innovative service and commissioning concept through
second SD card (automatic backup)
• Easy project transfer via standard cable
(standard Ethernet cable, standard USB cable)
• Maximum performance with short screen refresh times
• Suitable for extremely harsh industrial environments thanks to
extended approvals such as ATEX 2/22 and marine approvals
• Wide range of communication options: PROFIBUS and
PROFINET onboard; 2 x PROFINET with integrated switch for
7" models or larger; plus 1 x PROFINET with Gigabit support
for 15" models or larger
• All variants can be used as an OPC UA client or as an OPC DA
server
• Key-operated devices with LED in every function key and new
text input mechanism, similar to the keypads of mobile phones
• All keys have a service life of 2 million operations
• Configuring with the WinCC engineering software of the
TIA Portal
■ Technical specifications
6AV2124-2DC01-0AX0
6AV2124-0GC01-0AX0
6AV2124-0JC01-0AX0
6AV2124-0MC01-0AX0
SIMATIC HMI KTP400
Comfort
SIMATIC HMI TP700
Comfort
SIMATIC HMI TP900
Comfort
SIMATIC HMI TP1200
Comfort
Display
Design of display
TFT
TFT
TFT
TFT
Screen diagonal
4.3 in
7 in
9 in
12.1 in
Number of colors
16 777 200
16 777 200
16 777 200
16 777 200
Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution
480
272
800
480
800
480
1 280
800
Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight
80 000 h
Yes; 0-100 %
80 000 h
Yes; 0-100 %
80 000 h
Yes; 0-100 %
80 000 h
Yes; 0-100 %
Control elements
Keyboard fonts
• Number of function keys
4
0
0
0
Touch operation
• Design as touch screen
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Supply voltage
Type of supply voltage
DC
DC
DC
DC
Rated voltage/DC
24 V
24 V
24 V
24 V
Memory
Usable memory for user data
4 Mbyte
12 Mbyte
12 Mbyte
12 Mbyte
Type of output
Acoustics
• Speaker
No
Yes
Yes
Yes
Installation type/mounting
Mounting in portrait format
possible
2/26
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
6AV2124-2DC01-0AX0
6AV2124-0GC01-0AX0
6AV2124-0JC01-0AX0
6AV2124-0MC01-0AX0
SIMATIC HMI KTP400
Comfort
SIMATIC HMI TP700
Comfort
SIMATIC HMI TP900
Comfort
SIMATIC HMI TP1200
Comfort
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Interfaces
Number of RS 485 interfaces
1; RS 422/485 combined
1; RS 422/485 combined
1; RS 422/485 combined
1; RS 422/485 combined
Number of USB interfaces
1; USB 2.0
2; USB 2.0
2; USB 2.0
2; USB 2.0
Number of USB Mini B
interfaces
1; 5-pole
1; 5-pole
1; 5-pole
1; 5-pole
Number of SD card slots
2
2
2
2
1
2
2
2
1
2
2
2
Protocols
PROFINET
Yes
Yes
Yes
Yes
IRT supported
No
Yes
Yes
Yes
MRP supported
No
Yes
Yes
Yes
PROFIBUS
Yes
Yes
Yes
Yes
MPI
Yes
Yes
Yes
Yes
Degree and class of
protection
Type of protection
IP20
IP20
IP20
IP20
IP (at the front)
IP65
IP65
IP65
IP65
Enclosure type 4x at the front
Yes
Yes
Yes
Yes
Standards, approvals,
certificates
CE
Yes
Yes
Yes
Yes
cULus
Yes
Yes
Yes
Yes
GL
Yes
Yes
Yes
Yes
ABS
Yes
Yes
Yes
Yes
BV
Yes
Yes
Yes
Yes
DNV
Yes
Yes
Yes
Yes
LRS
Yes
Yes
Yes
Yes
Class NK
No; Available soon
No; Available soon
No; Available soon
No; Available soon
PRS
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0 °C
0 °C
0 °C
0 °C
50 °C
50 °C
50 °C
50 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
90 %
Configuration
Configuration software
• WinCC Comfort (TIA Portal)
Yes; from V11
Yes; from V11
Yes; from V11
Yes; from V11
Time of day
Clock
• Hardware clock
(real-time clock)
• Battery-backed
• Synchronizable
Industrial Ethernet
• Number of industrial Ethernet
interfaces
• Number of ports of the
integrated switch
Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Siemens ST 80 / ST PC · 2013
2
2/27
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
2
6AV2124-2DC01-0AX0
6AV2124-0GC01-0AX0
6AV2124-0JC01-0AX0
6AV2124-0MC01-0AX0
SIMATIC HMI KTP400
Comfort
SIMATIC HMI TP700
Comfort
SIMATIC HMI TP900
Comfort
SIMATIC HMI TP1200
Comfort
32
32
32
32
Functionality under WinCC
(TIA Portal)
Applications/options
• Internet Explorer
• Pocket Word
• Pocket Excel
• PDF Viewer
• Media Player
• SIMATIC WinCC [email protected]
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Visual Basic Scripts
Yes
Yes
Yes
Yes
Task planner
• time-controlled
• task-controlled
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2 000
50
4 000
200
4 000
200
4 000
200
256
Yes
Yes
1 024
Yes
Yes
1 024
Yes
Yes
1 024
Yes
Yes
300
2 Mbyte
Yes
300
2 Mbyte
Yes
300
2 Mbyte
Yes
1 024
2 048
2 048
2 048
50
400
400
400
Images
• Number of configurable
images
500
500
500
500
Archiving
• Number of archives per
device
10
50
50
50
Security
• Number of user groups
• Number of users
• SIMATIC Logon
50
50
Yes
50
50
Yes
50
50
Yes
50
50
Yes
Logging through printer
• Alarms
• Report (shift log)
• Hardcopy
• Electronic print to file
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Transfer (upload/download)
• MPI/PROFIBUS DP
• USB
• Ethernet
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Languages
Online languages
• Number of online/runtime
languages
With alarm logging system (incl.
buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive
Recipes
• Number of recipes
100
• Size of internal recipe memory 512 kbyte
Yes
• Recipe memory expandable
Variables
• Number of variables per
device
• Number of variables per
screen
2/28
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
6AV2124-2DC01-0AX0
6AV2124-0GC01-0AX0
6AV2124-0JC01-0AX0
6AV2124-0MC01-0AX0
SIMATIC HMI KTP400
Comfort
SIMATIC HMI TP700
Comfort
SIMATIC HMI TP900
Comfort
SIMATIC HMI TP1200
Comfort
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent
version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent
version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent
version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent
version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
• Network camera
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Mechanics/material
Type of housing (front)
• Plastic
• Aluminum
Yes
No
No
Yes
No
Yes
No
Yes
Dimensions
Width of the housing front
140 mm
214 mm
274 mm
330 mm
Height of housing front
116 mm
158 mm
190 mm
241 mm
Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height
123 mm
99 mm
197 mm
141 mm
251 mm
166 mm
310 mm
221 mm
Weight
Weight without packaging
0.6 kg
1.4 kg
1.9 kg
2.8 kg
Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
•
•
•
•
•
•
•
•
•
•
Allen Bradley (EtherNet/IP)
Allen Bradley (DF1)
Mitsubishi (MC TCP/IP)
Mitsubishi (FX)
OMRON (FINS TCP)
OMRON (LINK/Multilink)
Modicon (Modbus TCP/IP)
Modicon (Modbus)
OPC UA Client
OPC UA Server
6AV2124-1DC01-0AX0
6AV2124-1GC01-0AX0
6AV2124-1JC01-0AX0
6AV2124-1MC01-0AX0
6AV2124-1QC02-0AX0
SIMATIC HMI
KP400 Comfort
SIMATIC HMI
KP700 Comfort
SIMATIC HMI
KP900 Comfort
SIMATIC HMI
KP1200 Comfort
SIMATIC HMI
KP1500 Comfort
Display
Design of display
TFT
TFT
TFT
TFT
TFT
Screen diagonal
4.3 in
7 in
9 in
12.1 in
15.4 in
Number of colors
16 777 200
16 777 200
16 777 200
16 777 200
16 777 200
Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution
480
272
800
480
800
480
1 280
800
1 280
800
Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight
80 000 h
Yes; 0-100 %
80 000 h
Yes; 0-100 %
80 000 h
Yes; 0-100 %
80 000 h
Yes; 0-100 %
80 000 h
Yes; 0-100 %
Control elements
Keyboard fonts
• Number of function keys
8
24
26
34
36
Touch operation
• Design as touch screen
No
No
No
No
No
No
No
No
No
No
Supply voltage
Type of supply voltage
DC
DC
DC
DC
DC
Rated voltage/DC
24 V
24 V
24 V
24 V
24 V
Installation type/mounting
Mounting in portrait format
possible
Siemens ST 80 / ST PC · 2013
2/29
2
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
2
6AV2124-1DC01-0AX0
6AV2124-1GC01-0AX0
6AV2124-1JC01-0AX0
6AV2124-1MC01-0AX0
6AV2124-1QC02-0AX0
SIMATIC HMI
KP400 Comfort
SIMATIC HMI
KP700 Comfort
SIMATIC HMI
KP900 Comfort
SIMATIC HMI
KP1200 Comfort
SIMATIC HMI
KP1500 Comfort
Memory
Usable memory for user data
4 Mbyte
12 Mbyte
12 Mbyte
12 Mbyte
24 Mbyte
Type of output
Acoustics
• Speaker
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1; RS 422/485
combined
1; RS 422/485
combined
1; RS 422/485
combined
1; RS 422/485
combined
1; RS 422/485
combined
Number of USB interfaces
1; USB 2.0
2; USB 2.0
2; USB 2.0
2; USB 2.0
2; USB 2.0
Number of USB Mini B
interfaces
1; 5-pole
1; 5-pole
1; 5-pole
1; 5-pole
1; 5-pole
Number of SD card slots
2
2
2
2
2
1
2
2
2
3
1
2
2
2
2
Protocols
PROFINET
Yes
Yes
Yes
Yes
Yes
IRT supported
No
Yes
Yes
Yes
Yes
MRP supported
No
Yes
Yes
Yes
Yes
PROFIBUS
Yes
Yes
Yes
Yes
Yes
MPI
Yes
Yes
Yes
Yes
Yes
Degree and class of
protection
Type of protection
IP20
IP20
IP20
IP20
IP20
IP (at the front)
IP65
IP65
IP65
IP65
IP65
Enclosure type 4x at the front
Yes
Yes
Yes
Yes
Yes
Standards, approvals,
certificates
CE
Yes
Yes
Yes
Yes
Yes
cULus
Yes
Yes
Yes
Yes
Yes
GL
Yes
Yes
Yes
Yes
No
ABS
Yes
Yes
Yes
Yes
No
BV
Yes
Yes
Yes
Yes
No
DNV
Yes
Yes
Yes
Yes
No
LRS
Yes
Yes
Yes
Yes
No
Class NK
No; Available soon
No; Available soon
No; Available soon
No; Available soon
No
PRS
No
No
No
No
No
No; Available soon
No; Available soon
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
0 °C
0 °C
0 °C
0 °C
0 °C
50 °C
50 °C
50 °C
50 °C
50 °C
90 %
90 %
90 %
90 %
90 %
Time of day
Clock
• Hardware clock
(real-time clock)
• Battery-backed
• Synchronizable
Interfaces
Number of RS 485 interfaces
Industrial Ethernet
• Number of industrial Ethernet
interfaces
• Number of ports of the
integrated switch
Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical
installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Relative humidity
• max. relative humidity
2/30
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
6AV2124-1DC01-0AX0
6AV2124-1GC01-0AX0
6AV2124-1JC01-0AX0
6AV2124-1MC01-0AX0
6AV2124-1QC02-0AX0
SIMATIC HMI
KP400 Comfort
SIMATIC HMI
KP700 Comfort
SIMATIC HMI
KP900 Comfort
SIMATIC HMI
KP1200 Comfort
SIMATIC HMI
KP1500 Comfort
Yes; from V11
Yes; from V11
Yes; from V11
Yes; from V11
Yes; V11 SP2 or higher
32
32
32
32
32
Functionality under WinCC
(TIA Portal)
Applications/options
• Internet Explorer
• Pocket Word
• Pocket Excel
• PDF Viewer
• Media Player
• SIMATIC WinCC [email protected]
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Visual Basic Scripts
Yes
Yes
Yes
Yes
Yes
Task planner
• time-controlled
• task-controlled
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2 000
50
4 000
200
4 000
200
4 000
200
6 000
200
256
Yes
Yes
1 024
Yes
Yes
1 024
Yes
Yes
1 024
Yes
Yes
1 024
Yes
Yes
300
2 Mbyte
Yes
300
2 Mbyte
Yes
300
2 Mbyte
Yes
500
4 Mbyte
Yes
1 024
2 048
2 048
2 048
4 096
50
400
400
400
400
Images
• Number of configurable
images
500
500
500
500
750
Archiving
• Number of archives per
device
10
50
50
50
50
Security
• Number of user groups
• Number of users
• SIMATIC Logon
50
50
Yes
50
50
Yes
50
50
Yes
50
50
Yes
50
50
Yes
Logging through printer
• Alarms
• Report (shift log)
• Hardcopy
• Electronic print to file
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Transfer (upload/download)
• MPI/PROFIBUS DP
• USB
• Ethernet
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Configuration
Configuration software
• WinCC Comfort (TIA Portal)
Languages
Online languages
• Number of online/runtime
languages
With alarm logging system (incl.
buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive
Recipes
• Number of recipes
100
• Size of internal recipe memory 512 kbyte
Yes
• Recipe memory expandable
Variables
• Number of variables per
device
• Number of variables per
screen
Siemens ST 80 / ST PC · 2013
2/31
2
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
2
6AV2124-1DC01-0AX0
6AV2124-1GC01-0AX0
6AV2124-1JC01-0AX0
6AV2124-1MC01-0AX0
6AV2124-1QC02-0AX0
SIMATIC HMI
KP400 Comfort
SIMATIC HMI
KP700 Comfort
SIMATIC HMI
KP900 Comfort
SIMATIC HMI
KP1200 Comfort
SIMATIC HMI
KP1500 Comfort
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
• Network camera
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Mechanics/material
Type of housing (front)
• Plastic
• Aluminum
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes
Dimensions
Width of the housing front
152 mm
308 mm
362 mm
454 mm
483 mm
Height of housing front
188 mm
204 mm
230 mm
289 mm
310 mm
Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height
135 mm
171 mm
281 mm
177 mm
338 mm
206 mm
434 mm
269 mm
450 mm
291 mm
Weight
Weight without packaging
0.8 kg
2.2 kg
2.7 kg
4.4 kg
5.4 kg
Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
•
•
•
•
•
•
•
•
•
•
Allen Bradley (EtherNet/IP)
Allen Bradley (DF1)
Mitsubishi (MC TCP/IP)
Mitsubishi (FX)
OMRON (FINS TCP)
OMRON (LINK/Multilink)
Modicon (Modbus TCP/IP)
Modicon (Modbus)
OPC UA Client
OPC UA Server
2/32
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
6AV2124-0QC02-0AX0
6AV2124-0UC02-0AX0
6AV2124-0XC02-0AX0
SIMATIC HMI TP1500 Comfort
SIMATIC HMI TP1900 Comfort
SIMATIC HMI TP2200 Comfort
Display
Design of display
TFT
TFT
TFT
Screen diagonal
15.4 in
18.5 in
21.5 in
Number of colors
16 777 200
16 777 200
16 777 200
Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution
1 280
800
1 366
768
1 920
1 080
Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight
80 000 h
Yes; 0-100 %
50 000 h
Yes; 0-100 %
30 000 h
Yes; 0-100 %
Control elements
Keyboard fonts
• Number of function keys
0
0
0
Touch operation
• Design as touch screen
Yes
Yes
Yes
Yes
Yes
Yes
Supply voltage
Type of supply voltage
DC
DC
DC
Rated voltage/DC
24 V
24 V
24 V
Memory
Usable memory for user data
24 Mbyte
24 Mbyte
24 Mbyte
Type of output
Acoustics
• Speaker
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Interfaces
Number of RS 485 interfaces
1; RS 422/485 combined
1; RS 422/485 combined
1; RS 422/485 combined
Number of USB interfaces
2; USB 2.0
2; USB 2.0
2; USB 2.0
Number of USB Mini B
interfaces
1; 5-pole
1; 5-pole
1; 5-pole
Number of SD card slots
2
2
2
3
3
3
2
2
2
Protocols
PROFINET
Yes
Yes
Yes
IRT supported
Yes
Yes
Yes
MRP supported
Yes
Yes
Yes
PROFIBUS
Yes
Yes
Yes
MPI
Yes
Yes
Yes
Degree and class of
protection
Type of protection
IP20
IP20
IP20
IP (at the front)
IP65
IP65
IP65
Enclosure type 4x at the front
Yes
Yes
Yes
Installation type/mounting
Mounting in portrait format
possible
Time of day
Clock
• Hardware clock
(real-time clock)
• Battery-backed
• Synchronizable
Industrial Ethernet
• Number of industrial Ethernet
interfaces
• Number of ports of the
integrated switch
Siemens ST 80 / ST PC · 2013
2
2/33
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
2
6AV2124-0QC02-0AX0
6AV2124-0UC02-0AX0
6AV2124-0XC02-0AX0
SIMATIC HMI TP1500 Comfort
SIMATIC HMI TP1900 Comfort
SIMATIC HMI TP2200 Comfort
Standards, approvals,
certificates
CE
Yes
Yes
Yes
cULus
Yes
Yes
Yes
GL
No
No
No
ABS
No
No
No
BV
No
No
No
DNV
No
No
No
LRS
No
No
No
Class NK
No
No
No
PRS
No
No
No
No
No
Yes
No
No
Yes
No
No
Yes
Yes
Yes
Yes
0 °C
0 °C
0 °C
50 °C
45 °C
45 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
Configuration
Configuration software
• WinCC Comfort (TIA Portal)
Yes; V11 SP2 or higher
Yes; V11 SP2 or higher
Yes; V11 SP2 or higher
32
32
32
Functionality under WinCC
(TIA Portal)
Applications/options
• Internet Explorer
• Pocket Word
• Pocket Excel
• PDF Viewer
• Media Player
• SIMATIC WinCC [email protected]
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Visual Basic Scripts
Yes
Yes
Yes
Task planner
• time-controlled
• task-controlled
Yes
Yes
Yes
Yes
Yes
Yes
6 000
200
6 000
200
6 000
200
1 024
Yes
Yes
1 024
Yes
Yes
1 024
Yes
Yes
500
4 Mbyte
Yes
500
4 Mbyte
Yes
4 096
4 096
4 096
400
400
400
Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical
installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Languages
Online languages
• Number of online/runtime
languages
With alarm logging system (incl.
buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive
Recipes
• Number of recipes
500
• Size of internal recipe memory 4 Mbyte
Yes
• Recipe memory expandable
Variables
• Number of variables per
device
• Number of variables per
screen
2/34
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Technical specifications (continued)
6AV2124-0QC02-0AX0
6AV2124-0UC02-0AX0
6AV2124-0XC02-0AX0
SIMATIC HMI TP1500 Comfort
SIMATIC HMI TP1900 Comfort
SIMATIC HMI TP2200 Comfort
Images
• Number of configurable
images
750
750
750
Archiving
• Number of archives per
device
50
50
50
Security
• Number of user groups
• Number of users
• SIMATIC Logon
50
50
Yes
50
50
Yes
50
50
Yes
Logging through printer
• Alarms
• Report (shift log)
• Hardcopy
• Electronic print to file
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Yes
Yes
Yes
Yes; pdf, html
Transfer (upload/download)
• MPI/PROFIBUS DP
• USB
• Ethernet
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)
• OPC UA Client
• OPC UA Server
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
• Network camera
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Mechanics/material
Type of housing (front)
• Plastic
• Aluminum
No
Yes
No
Yes
No
Yes
Dimensions
Width of the housing front
415 mm
483 mm
560 mm
Height of housing front
310 mm
337 mm
380 mm
Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height
396 mm
291 mm
465 mm
319 mm
542 mm
362 mm
Weight
Weight without packaging
5.2 kg
6.5 kg
7.1 kg
Siemens ST 80 / ST PC · 2013
2
2/35
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Ordering data
Order No.
SIMATIC HMI Comfort Panels,
Key and Touch
SIMATIC HMI KTP400 Comfort
6AV2124-2DC01-0AX0
SIMATIC HMI Comfort Panels,
Touch
2
SIMATIC HMI TP700 Comfort
6AV2124-0GC01-0AX0
SIMATIC HMI TP900 Comfort
6AV2124-0JC01-0AX0
SIMATIC HMI TP1200 Comfort
6AV2124-0MC01-0AX0
SIMATIC HMI TP1500 Comfort
6AV2124-0QC02-0AX0
SIMATIC HMI TP1900 Comfort
6AV2124-0UC02-0AX0
SIMATIC HMI TP2200 Comfort
6AV2124-0XC02-0AX0
SIMATIC HMI Comfort Panels, Key
SIMATIC HMI KP400 Comfort
6AV2124-1DC01-0AX0
SIMATIC HMI KP700 Comfort
6AV2124-1GC01-0AX0
SIMATIC HMI KP900 Comfort
6AV2124-1JC01-0AX0
SIMATIC HMI KP1200 Comfort
6AV2124-1MC01-0AX0
SIMATIC HMI KP1500 Comfort
6AV2124-1QC02-0AX0
2/36
Siemens ST 80 / ST PC · 2013
Order No.
Starter kits for SIMATIC HMI
Comfort Panels
Consisting of:
the respective SIMATIC HMI
Comfort Panel, SIMATIC WinCC
Comfort, Ethernet cable, 2 m
SIMATIC HMI memory card 2 GB
10 protective films for touch screen
devices
Starter kit for SIMATIC HMI
KTP400 Comfort,
Key and Touch
6AV2181-4DB20-0AX0
Starter kit for SIMATIC HMI
TP700 Comfort, Touch
6AV2181-4GB00-0AX0
Starter kit for SIMATIC HMI
TP900 Comfort, Touch
6AV2181-4JB00-0AX0
Starter kit for SIMATIC HMI
TP1200 Comfort, Touch
6AV2181-4MB00-0AX0
Starter kit for SIMATIC HMI
TP1500 Comfort, Touch
6AV2181-4QB00-0AX0
Starter kit for SIMATIC HMI
TP1900 Comfort, Touch
6AV2181-4UB00-0AX0
Starter kit for SIMATIC HMI
TP2200 Comfort, Touch
6AV2181-4XB00-0AX0
Starter kit for SIMATIC HMI
KP400 Comfort, Key
6AV2181-4DB10-0AX0
Starter kit for SIMATIC HMI
KP700 Comfort, Key
6AV2181-4GB10-0AX0
Starter kit for SIMATIC HMI
KP900 Comfort, Key
6AV2181-4JB10-0AX0
Starter kit for SIMATIC HMI
KP1200 Comfort, Key
6AV2181-4MB10-0AX0
Starter kit for SIMATIC HMI
KP1500 Comfort, Key
6AV2181-4QB10-0AX0
Accessories
See HMI accessories,
from page 2/96
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
■ Dimensional drawings
2
219
241
140
158
138.8
All dimensions in mm. For installation cutout, see technical specifications.
32.5
214
32.5
330
62.8
64.3
69
196
70.5
G_ST80_XX_00449
308
274
G_ST80_XX_00451
182
289
310
164
138.8
TP1200 Comfort
190
TP700 Comfort
194.7
32.5
47.6
415
63.1
TP900 Comfort
79.3
G_ST80_XX_00511
194.7
73.1
69.3
G_ST80_XX_00450
249
281
394
TP1500 Comfort
Siemens ST 80 / ST PC · 2013
2/37
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
483
170
188
182
337
2
317
98
■ Dimensional drawings (continued)
47.6
18
73.1
152
48
79.3
134
463
308
47.6
69
280
79.3
TP2200 Comfort
2/38
Siemens ST 80 / ST PC · 2013
G_ST80_XX_00513
194.7
281
138.8
62.8
73.1
540
32.5
KP700 Comfort
G_ST80_XX_00445
560
176
204
182
360
KP400 Comfort
380
TP1900 Comfort
G_ST80_XX_00444
G_ST80_XX_00512
281
55.8
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
182
289
310
47.6
483
32.5
62.8
73.1
69
79.3
G_ST80_XX_00446
336
2
194.7
281
448
KP1500 Comfort
140
454
98
116
267
289
138.8
KP900 Comfort
G_ST80_XX_00510
362
204
138.8
230
■ Dimensional drawings (continued)
18
32.5
48.6
64.5
54.8
70.5
122
KP1200 Comfort
G_ST80_XX_00448
G_ST80_XX_00447
432
194.7
KTP400 Comfort
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-comfort-panels
You can find an overview of approved printers, supply sources
and printer settings on the Internet at:
http://support.automation.siemens.com/WW/view/en/11376409
Note
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
Siemens ST 80 / ST PC · 2013
2/39
© Siemens AG 2013
Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels
■ Overview
2
• Excellent HMI functionality for demanding applications
• Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and 22"
diagonals (all 16 million colors) with up to 40% more visualization area as compared to the predecessor devices
• Integrated high-end functionality with archives, scripts,
PDF/Word/Excel viewer, Internet Explorer, Media Player
• Dimmable displays from 0 to 100% via PROFIenergy, via the
HMI project or via a controller
• Modern industrial design, cast aluminum fronts for 7" upwards
• Upright installation for all touch devices
• Optimal selection option: seven touch and five key versions
are available
2/40
Siemens ST 80 / ST PC · 2013
• Data security in the event of a power failure for the device and
for the SIMATIC HMI Memory Card
• Innovative service and commissioning concept through
second SD card (automatic backup)
• Easy project transfer via standard cable
(standard Ethernet cable, standard USB cable)
• Maximum performance with short screen refresh times
• Suitable for extremely harsh industrial environments thanks to
extended approvals such as ATEX 2/22
• Wide range of communication options: PROFIBUS and
PROFINET onboard; 2x PROFINET with integrated switch for
7" models or larger; plus 1 additional PROFINET with Gigabit
support for 15" models or larger
• All variants can be used as an OPC UA client or as an OPC DA
server
• Key-operated devices with LED in every function key and new
text input mechanism, similar to the keypads of mobile phones
• Key-operated devices with stamped keys for optimum tactile
feedback
• All keys have a service life of 2 million operations
• Configuring with the WinCC engineering software of the
TIA Portal
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific information was added.
© Siemens AG 2013
Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels
■ Technical specifications
Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Extended ambient conditions
• Relative humidity
- With condensation/
maximum/tested in accordance with IEC 60068-2-38
• Resistance
- to biologically active
substances
- to chemically active
substances
- to mechanically active
substances
Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Extended ambient conditions
• Relative humidity
- With condensation/
maximum/tested in accordance with IEC 60068-2-38
• Resistance
- to biologically active
substances
- to chemically active
substances
- to mechanically active
substances
6AG1124-2DC01-4AX0
6AG1124-0GC01-4AX0
6AG1124-0JC01-4AX0
6AG1124-0MC01-4AX0
SIPLUS HMI KTP400
Comfort
SIPLUS HMI TP700
Comfort
SIPLUS HMI TP900
Comfort
SIPLUS HMI TP1200
Comfort
0 °C
0 °C
0 °C
0 °C
50 °C
50 °C
50 °C
50 °C
100 %
100 %
100 %
100 %
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2
6AG1124-1DC01-4AX0
6AG1124-1GC01-4AX0
6AG1124-1JC01-4AX0
6AG1124-1MC01-4AX0
6AG1124-1QC02-4AX0
SIPLUS HMI KTP400
Comfort
SIPLUS HMI KP700
Comfort
SIPLUS HMI KP900
Comfort
SIPLUS HMI KP1200
Comfort
SIPLUS HMI KP1500
Comfort
0 °C
0 °C
0 °C
0 °C
0 °C
50 °C
50 °C
50 °C
50 °C
50 °C
100 %
100 %
100 %
100 %
100 %
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Siemens ST 80 / ST PC · 2013
2/41
© Siemens AG 2013
Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels
■ Technical specifications (continued)
2
Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Extended ambient conditions
• Relative humidity
- With condensation/
maximum/tested in accordance with IEC 60068-2-38
• Resistance
- to biologically active
substances
- to chemically active
substances
- to mechanically active
substances
2/42
6AG1124-0QC02-4AX0
6AG1124-0UC02-4AX0
6AG1124-0XC02-4AX0
SIPLUS HMI TP1500 Comfort
SIPLUS HMI TP1900 Comfort
SIPLUS HMI TP2200 Comfort
0 °C
0 °C
0 °C
50 °C
45 °C
45 °C
100 %
100 %
100 %
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels
■ Ordering data
Order No.
SIPLUS HMI KTP400 Comfort
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-comfort-panels
SIPLUS HMI Comfort Panels,
Keys and Touch
6AG1124-2DC01-4AX0
SIPLUS HMI Comfort Panels,
Touch
SIPLUS HMI TP700 Comfort
6AG1124-0GC01-4AX0
SIPLUS HMI TP900 Comfort
6AG1124-0JC01-4AX0
SIPLUS HMI TP1200 Comfort
6AG1124-1MC01-4AX0
SIPLUS HMI TP1500 Comfort
6AG1124-0QC02-4AX0
SIPLUS HMI TP1900 Comfort
6AG1124-0UC02-4AX0
SIPLUS HMI TP2200 Comfort
6AG1124-0XC02-4AX0
You can find an overview of approved printers, supply sources
and printer settings on the Internet at:
http://support.automation.siemens.com/WW/view/en/11376409
Note
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
SIPLUS HMI Comfort Panels,
Keys
SIPLUS HMI KP400 Comfort
6AG1124-1DC01-4AX0
SIPLUS HMI KP700 Comfort
6AG1124-1GC01-4AX0
SIPLUS HMI KP900 Comfort
6AG1124-1JC01-4AX0
SIPLUS HMI KP1200 Comfort
6AG1124-1MC01-4AX0
SIPLUS HMI KP1500 Comfort
6AG1124-1QC02-4AX0
Accessories
See HMI accessories,
from page 2/26
Siemens ST 80 / ST PC · 2013
2/43
2
© Siemens AG 2013
Operator panels
Mobile Panels
Mobile Panels
■ Overview
2
SIMATIC Mobile Panel
• Mobile operator panel for direct operator control of the plant
and machine from any point
• Supports an optimum view of the workpiece or process and,
at the same time, direct access and visual contact with the
operator panel
• Versatile use thanks to easy unplugging and replugging
during normal operation (Mobile Panel 177 and
Mobile Panel 277) or
• Wireless freedom (Mobile Panel 277(F) IWLAN)
• Pixel-graphics, high-luminance color display with touch
screen (analog/resistive)
• PROFIBUS or PROFINET communication, PROFINET over
WLAN for Mobile Panel 277(F) IWLAN
• Freely-configurable function keys with customized labels
(with LED) (not for Mobile Panel 277 10")
SIMATIC Mobile Panel 177 and SIMATIC Mobile Panel 277
• Two three-stage acknowledgement buttons;
Optional versions include:
- STOP button
- STOP button, handwheel, key-operated switch and
illuminated pushbutton (not for Mobile Panel 277 10")
• Communication is supported via a serial link, MPI/PROFIBUS
or PROFINET
• Connection point recognition for local identification of the
device based on the connection point ID
• Fast system availability after plugging into the connection
boxes
• Connection to the controller and power supply is made via the
connection box and the connecting cable
2/44
Siemens ST 80 / ST PC · 2013
SIMATIC Mobile Panel 277(F) IWLAN
• Wireless, mobile operator panel for flexible and locationindependent system and machine operation
• WLAN communication in accordance with
IEEE 802.11 (a/b/g/h) and PROFINET support
• Powerful batteries and flexible concept for changing permit
battery replacement "on the fly" without interrupting operation
• Effective range limitation and the local identification of the
device by using transponder technology
• Low-cost, safety-related mobile operator control and
monitoring via RFID technology (MOBY D) for plants with
pre-installed safety resources (e.g. robot cells)
• Optional variants with: Handwheel, key switch and illuminated
pushbutton
• Fail-safe operator controls of the
SIMATIC Mobile Panel 277F IWLAN using PROFIsafe:
- Two three-stage acknowledgment buttons
- Emergency stop button
IWLAN Access Points SCALANCE W for
SIMATIC Mobile Panel 277(F) IWLAN
• The Access Points of the product line SCALANCE W-780 are
ideally suited for setting up Industrial Wireless LAN (IWLAN)
radio networks for 2.4 GHz and 5 GHz with data rates of up to
54 Mbps; they can be used for all applications that require a
high degree of operational reliability, even under extremely
harsh ambient conditions
• Suitable for any application:
- SCALANCE W-788 for cabinet-free installation
- SCALANCE W-786 for cabinet-free installation, also with
integral antennas
- SCALANCE W-784 for installation in control cabinets or
integration into devices
• Wireless communication suitable for use in applications with
high real-time and reliability requirements, such as PROFINET,
PROFIsafe or video
• Standard-compliant thanks to IEEE 802.11 support, additional
functional expansions especially for use with increased
reliability
• Effective encryption mechanisms protect against
unauthorized access, spying, tapping, and corruption
• The SINEMA E engineering tool, wizards and online help
support planning, simulation, configuration and documentation; easy management with the web server and SNMP
• Fast commissioning of the Access Points thanks to the
optional swap medium PRESET-PLUG and fast device
replacement in the event of a fault thanks to the optional swap
medium C-PLUG (Configuration Plug)
• Accessories such as antennas, connectors, cables incl.
RCoax cables (radiating cables) that are tuned to one another
for a reliable radio link.
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Overview
2
SIMATIC Mobile Panel 177
■ Technical specifications
6AV6645-0AA01-0AX0
6AV6645-0AB01-0AX0
6AV6645-0AC01-0AX0
with integrated acknowledgment
button
with integrated acknowledgment
button and STOP button
with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
Display
Size
5.7" (121 mm x 92 mm)
5.7" (121 mm x 92 mm)
5.7" (121 mm x 92 mm)
Display type
STN, 256 colors
STN, 256 colors
STN, 256 colors
Resolution (pixels)
• Resolution (WxH in pixel)
320 x 240
320 x 240
320 x 240
Backlighting
• MTBF backlighting (at 25 °C)
• MTBF backlighting (at 25 °C)
about 50,000 hours
50 000 h
about 50,000 hours
50 000 h
about 50,000 hours
50 000 h
Control elements
Operating options
Keys and Touch
Keys and Touch
Keys and Touch
Function keys, programmable
14 function keys, 8 with LEDs
14 function keys, 8 with LEDs
14 function keys, 8 with LEDs
Keyboard fonts
• System keys
0
0
0
Touch operation
• Touch screen
Analog, resistive
Analog, resistive
Analog, resistive
Special operator controls
• Stop button
• Acknowledgement button
• Key-operated switch
• Illuminated pushbutton
• Handwheel
No
Yes
No
No
No
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Supply voltage
Supply voltage
via connection box
via connection box
via connection box
Processor
Processor
RISC 32-bit, 200 MHz
RISC 32-bit, 200 MHz
RISC 32-bit, 200 MHz
Memory
Type
Flash / RAM
Flash / RAM
Flash / RAM
2048 KB of usable memory for
user data / no user memory for options
2048 KB of usable memory for
user data / no user memory for options
2048 KB of usable memory for
user data / no user memory for options
maximum buffer time 10 min
maximum buffer time 10 min
maximum buffer time 10 min
Usable memory for user data
Battery
Backup battery
• Battery operation
Siemens ST 80 / ST PC · 2013
2/45
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
2
6AV6645-0AA01-0AX0
6AV6645-0AB01-0AX0
6AV6645-0AC01-0AX0
with integrated acknowledgment
button
with integrated acknowledgment
button and STOP button
with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
Interfaces
Interfaces
1 x RS422, 1 x RS485 (max. 12 Mbit/s)
1 x RS422, 1 x RS485 (max. 12 Mbit/s)
1 x RS422, 1 x RS485 (max. 12 Mbit/s)
USB port
No
No
No
Number of USB interfaces
0
0
0
PC card slot
No
No
No
CF card slot
No
No
No
SD card slot
No
Multimedia card/SD card slot
combined
combined
combined
Industrial Ethernet
• Industrial Ethernet interface
No
No
No
Degree and class of
protection
IP65 enclosure
Yes
Yes
Yes
Standards, approvals,
certificates
Certifications
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE
Yes
Yes
Yes
cULus
Yes
Yes
Yes
C-TICK
Yes
Safety category according to
EN954-1
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
d
d
d
Ambient conditions
Drop height
1.5 m
1.5 m
1.5 m
Operating temperature
• Operation
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
Storage/transport temperature
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Relative humidity
• max. relative humidity
80 %
80 %
80 %
Operating systems
Operating system
Windows CE
Windows CE
Windows CE
5
5
5
Functionality under WinCC
(TIA Portal)
Libraries
Yes
Yes
Yes
Task planner
Yes
Yes
Yes
With alarm logging system (incl.
buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages
2 000
Yes
Yes
2 000
Yes
Yes
2 000
Yes
Yes
Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory
100
200
200
32 KB integrated Flash, expandable
100
200
200
32 KB integrated Flash, expandable
100
200
200
32 KB integrated Flash, expandable
Highest safety class achievable
in safety mode
• Performance Level in accordance with EN ISO 13849-1
Languages
Online languages
• Number of online/runtime
languages
2/46
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
Variables
• Number of variables per
device
• Limit values
• Multiplexing
6AV6645-0AA01-0AX0
6AV6645-0AB01-0AX0
6AV6645-0AC01-0AX0
with integrated acknowledgment
button
with integrated acknowledgment
button and STOP button
with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
1 024
1 024
1 024
Yes
Yes
Yes
Yes
Yes
Yes
500
500
500
2,500 text elements
Bit maps, vector graphics
2,500 text elements
Bit maps, vector graphics
2,500 text elements
Bit maps, vector graphics
With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons
With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons
With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons
300
300
300
100
100
100
0
0
0
Security
• Number of user groups
• Number of user rights
• Password export/import
50
32
Yes
50
32
Yes
50
32
Yes
Data carrier support
• PC card
• CF card
No
No
No
No
No
No
Logging through printer
• Recording/Printing
-
-
-
MPI/PROFIBUS DP, serial, automatic
transfer recognition
MPI/PROFIBUS DP, serial, automatic
transfer recognition
MPI/PROFIBUS DP, serial, automatic
transfer recognition
• S7-1200
• S7-1500
S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes
S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes
S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes
Expandability/openness
• Open Platform Program
Yes
Yes
Yes
I/O
I/O devices
• Multi Media Card
Yes
Yes
Yes
Mechanics/material
Type of housing (front)
Plastic
Plastic
Plastic
Dimensions
Housing diameter/depth (mm)
Dia 245 mm / D 58 mm
Dia 245 mm / D 58 mm
Dia 245 mm / D 58 mm
Weight
Weight
1.3 kg
1.3 kg
1.3 kg
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects
Lists
• Number of text lists per
project
• Number of graphics lists per
project
Archiving
• Number of archives per
device
Transfer (upload/download)
• Transfer of configuration
Process coupling
• Connection to controller
Siemens ST 80 / ST PC · 2013
2
2/47
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
2
6AV6645-0BA01-0AX0
6AV6645-0BB01-0AX0
6AV6645-0BC01-0AX0
with integrated acknowledgment
button
with integrated acknowledgment
button and STOP button
with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
Display
Size
5.7" (121 mm x 92 mm)
5.7" (121 mm x 92 mm)
5.7" (121 mm x 92 mm)
Display type
STN, 256 colors
STN, 256 colors
STN, 256 colors
Resolution (pixels)
• Resolution (WxH in pixel)
320 x 240
320 x 240
320 x 240
Backlighting
• MTBF backlighting (at 25 °C)
• MTBF backlighting (at 25 °C)
about 50,000 hours
50 000 h
about 50,000 hours
50 000 h
about 50,000 hours
50 000 h
Control elements
Operating options
Keys and Touch
Keys and Touch
Keys and Touch
Function keys, programmable
14 function keys, 8 with LEDs
14 function keys, 8 with LEDs
14 function keys, 8 with LEDs
Keyboard fonts
• System keys
0
0
0
Touch operation
• Touch screen
Analog, resistive
Analog, resistive
Analog, resistive
Special operator controls
• Stop button
• Acknowledgement button
• Key-operated switch
• Illuminated pushbutton
• Handwheel
No
Yes
No
No
No
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Supply voltage
Supply voltage
via connection box
via connection box
via connection box
Processor
Processor
RISC 32-bit, 200 MHz
RISC 32-bit, 200 MHz
RISC 32-bit, 200 MHz
Memory
Type
Flash / RAM
Flash / RAM
Flash / RAM
2048 KB of usable memory for user
data / no user memory for options
2048 KB of usable memory for user
data / no user memory for options
2048 KB of usable memory for user
data / no user memory for options
Battery
Backup battery
• Battery operation
maximum buffer time 10 min
maximum buffer time 10 min
maximum buffer time 10 min
Interfaces
Interfaces
1 x RS485, 1 x Ethernet (RJ45)
1 x RS485, 1 x Ethernet (RJ45)
1 x RS485, 1 x Ethernet (RJ45)
USB port
No
No
No
Number of USB interfaces
0
0
0
PC card slot
No
No
No
CF card slot
No
No
No
Multimedia card/SD card slot
combined
combined
combined
Industrial Ethernet
• Industrial Ethernet interface
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
Protocols
PROFINET
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Usable memory for user data
Supports protocol for
PROFINET IO
Degree and class of
protection
IP65 enclosure
2/48
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
6AV6645-0BA01-0AX0
6AV6645-0BB01-0AX0
6AV6645-0BC01-0AX0
with integrated acknowledgment
button
with integrated acknowledgment
button and STOP button
with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
Standards, approvals,
certificates
Certifications
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE
Yes
Yes
Yes
cULus
Yes
Yes
Yes
Safety category according to
EN954-1
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
d
d
d
Ambient conditions
Drop height
1.5 m
1.5 m
1.5 m
Operating temperature
• Operation
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
Storage/transport temperature
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Relative humidity
• max. relative humidity
80 %
80 %
80 %
Operating systems
Operating system
Windows CE
Windows CE
Windows CE
5
5
5
Functionality under WinCC
(TIA Portal)
Libraries
Yes
Yes
Yes
Task planner
Yes
Yes
Yes
With alarm logging system (incl.
buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages
2 000
Yes
Yes
2 000
Yes
Yes
2 000
Yes
Yes
Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory
100
200
200
32 KB integrated Flash, expandable
100
200
200
32 KB integrated Flash, expandable
100
200
200
32 KB integrated Flash, expandable
1 024
1 024
1 024
Yes
Yes
Yes
Yes
Yes
Yes
500
500
500
2,500 text elements
Bit maps, vector graphics
2,500 text elements
Bit maps, vector graphics
2,500 text elements
Bit maps, vector graphics
With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons
With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons
With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons
Highest safety class achievable
in safety mode
• Performance Level in accordance with EN ISO 13849-1
Languages
Online languages
• Number of online/runtime
languages
Variables
• Number of variables per
device
• Limit values
• Multiplexing
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects
Siemens ST 80 / ST PC · 2013
2
2/49
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
■ Technical specifications (continued)
2
Lists
• Number of text lists
per project
• Number of graphics lists
per project
6AV6645-0BA01-0AX0
6AV6645-0BB01-0AX0
6AV6645-0BC01-0AX0
with integrated acknowledgment
button
with integrated acknowledgment
button and STOP button
with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
300
300
300
100
100
100
0
0
0
Security
• Number of user groups
• Number of user rights
• Password export/import
50
32
Yes
50
32
Yes
50
32
Yes
Data carrier support
• PC card
• CF card
No
No
No
No
No
No
Logging through printer
• Recording/Printing
-
-
-
Serial, Ethernet, automatic transfer
recognition
Serial, Ethernet, automatic transfer
recognition
Serial, Ethernet, automatic transfer
recognition
• S7-1200
• S7-1500
S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
Yes
Yes
S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
Yes
Yes
S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
Yes
Yes
Expandability/openness
• Open Platform Program
Yes
Yes
Yes
I/O
I/O devices
• Multi Media Card
Printer
Yes
Printer
Yes
Printer
Yes
Mechanics/material
Type of housing (front)
Plastic
Plastic
Plastic
Dimensions
Housing diameter/depth (mm)
Dia 245 mm / D 58 mm
Dia 245 mm / D 58 mm
Dia 245 mm / D 58 mm
Weight
Weight
1.3 kg
1.3 kg
1.3 kg
Archiving
• Number of archives
per device
Transfer (upload/download)
• Transfer of configuration
Process coupling
• Connection to controller
2/50
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
SIMATIC Mobile Panel 177 PN
(PROFINET) 1)
• With integrated acknowledgement
button
• With integrated acknowledgement
button and STOP button
• With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and
illuminated pushbutton
Order No.
6AV6645-0AA01-0AX0
■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
6AV6645-0AB01-0AX0
123.9
6AV6645-0AC01-0AX0
7.80
2
6AV6645-0BA01-0AX0
121.7
6AV6645-0BB01-0AX0
245
SIMATIC Mobile Panel 177 DP
(MPI/PROFIBUS) 1)
• With integrated acknowledgement
button
• With integrated acknowledgement
button and STOP button
• With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and
illuminated pushbutton
92.3
■ Ordering data
6AV6645-0BC01-0AX0
You can find the manuals for the
Mobile Panels on the Internet at:
http://support.automation.siemens.com/WW/view/en/11599011/
133300
SIMATIC HMI Manual Collection
Electronic documentation on DVD,
5 languages (English, German,
French, Italian and Spanish); contains: all currently available user
manuals, device manuals and
communication manuals for
SIMATIC HMI
61.3
6AV6691-1SA01-0AX0
G_ST80_XX_00046
Documentation
Mobile Panel 177, front and side view
■ More information
System components for
Mobile Panels
Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels
DP connection box for
Mobile Panels
(MPI/PROFIBUS)
• Basic
• Plus
Note
6AV6671-5AE00-0AX0
6AV6671-5AE10-0AX0
PN connection box for
Mobile Panel (PROFINET)
• Basic
• Plus
6AV6671-5AE01-0AX0
6AV6671-5AE11-0AX0
Connecting cable and
accessories for Mobile Panels
See HMI accessories,
from page 2/99
1)
The system components (connecting cables and connection boxes) must
be ordered separately.
2)
Delivery time approximately 6 weeks
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
Siemens ST 80 / ST PC · 2013
2/51
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Overview
2
SIMATIC Mobile Panel 277 10"
SIMATIC Mobile Panel 277 8"
■ Technical specifications
6AV6645-0CA01-0AX0
6AV6645-0CB01-0AX0
6AV6645-0CC01-0AX0
6AV6645-0BE02-0AX0
8" with integrated
acknowledgment button
8" with integrated
acknowledgment button
and STOP button
8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton
10" with integrated
acknowledgment button
and STOP button
Display
Size
7.5"
7.5"
7.5"
10.4"
Display type
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
Resolution (pixels)
• Resolution (WxH in pixel)
640 x 480
640 x 480
640 x 480
800 x 600
Backlighting
• MTBF backlighting (at 25 °C)
• MTBF backlighting (at 25 °C)
about 50,000 hours
50 000 h
about 50,000 hours
50 000 h
about 50,000 hours
50 000 h
about 50,000 hours
50 000 h
Control elements
Operating options
Keys and Touch
Keys and Touch
Keys and Touch
Touch
Function keys, programmable
18 function keys, 18 with
LEDs
18 function keys, 18 with
LEDs
18 function keys, 18 with
LEDs
none
Connection for mouse/
keyboard/barcode reader
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
Keyboard fonts
• System keys
0
Touch operation
• Touch screen
Analog, resistive
Analog, resistive
Analog, resistive
Analog, resistive
Special operator controls
• Stop button
• Acknowledgement button
• Key-operated switch
• Illuminated pushbutton
No
Yes
No
No
Yes
Yes
No
No
Yes
Yes
No
No
• Handwheel
No
No
Yes
Yes
Yes
Yes; Two illuminated
pushbuttons
Yes
2/52
Siemens ST 80 / ST PC · 2013
No
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Technical specifications (continued)
6AV6645-0CA01-0AX0
6AV6645-0CB01-0AX0
6AV6645-0CC01-0AX0
6AV6645-0BE02-0AX0
8" with integrated
acknowledgment button
8" with integrated
acknowledgment button
and STOP button
8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton
10" with integrated
acknowledgment button
and STOP button
Supply voltage
Supply voltage
via connection box
via connection box
via connection box
via connection box, DC
Processor
Processor
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
ARM, 520
Memory
Type
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
6 MB usable memory for user
data
6 MB usable memory for user
data
6 MB usable memory for user
data
6 MB usable memory for user
data
maximum buffer time 10 min
maximum buffer time 10 min
maximum buffer time 10 min
maximum buffer time 10 min
5h
500
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)
1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)
1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)
1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)
USB port
1 x USB
1 x USB
1 x USB
1 x USB
Multi Media Card slot
1 MMC/SD card slot
1 MMC/SD card slot
1 MMC/SD card slot
Usable memory for user data
Battery
Backup battery
• Battery operation
- Charging duration
- Number of loading cycles,
min
Time of day
Clock
• Type
Interfaces
Interfaces
Multimedia card/SD card slot
combined
Industrial Ethernet
• Industrial Ethernet interface
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
Protocols
PROFINET
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Degree and class of
protection
IP65 enclosure
Yes
Yes
Yes
Yes
Standards, approvals,
certificates
Certifications
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
CE, cULus, C-TICK, SIBE
Safety category according to
EN954-1 (acknowledgment
button, STOP button if present) 3
Safety category according to
EN954-1 (acknowledgment
button, STOP button if present) 3
Safety category according to
EN954-1 (acknowledgment
button, STOP button if present) 3
Safety category according to
EN954-1 (acknowledgment
button, STOP button if present) 3
d
d
d
d
Supports protocol for
PROFINET IO
Safety category according to
EN954-1
Highest safety class achievable
in safety mode
• Performance Level in accordance with EN ISO 13849-1
Siemens ST 80 / ST PC · 2013
2/53
2
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Technical specifications (continued)
2
6AV6645-0CA01-0AX0
6AV6645-0CB01-0AX0
6AV6645-0CC01-0AX0
6AV6645-0BE02-0AX0
8" with integrated
acknowledgment button
8" with integrated
acknowledgment button
and STOP button
8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton
10" with integrated
acknowledgment button
and STOP button
Ambient conditions
Drop height
1.2 m
1.2 m
1.2 m
1m
Operating temperature
• Operation
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
Storage/transport temperature
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Relative humidity
• max. relative humidity
80 %
80 %
80 %
80 %
Operating systems
Operating system
Windows CE
Windows CE
Windows CE
Windows CE
16
16
16
16
Functionality under WinCC
(TIA Portal)
Libraries
Yes
Yes
Yes
Yes
Task planner
Yes
Yes
Yes
Yes
With alarm logging system (incl.
buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages
4 000
Yes
Yes
4 000
Yes
Yes
4 000
Yes
Yes
4 000
Yes
Yes
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
300
200
1 000
64 KB integrated Flash,
expandable
2 048
2 048
2 048
2 048
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
500
500
500
500
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Languages
Online languages
• Number of online/runtime
languages
Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory
Variables
• Number of variables
per device
• Limit values
• Multiplexing
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects
2/54
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Technical specifications (continued)
6AV6645-0CA01-0AX0
6AV6645-0CB01-0AX0
6AV6645-0CC01-0AX0
6AV6645-0BE02-0AX0
8" with integrated
acknowledgment button
8" with integrated
acknowledgment button
and STOP button
8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton
10" with integrated
acknowledgment button
and STOP button
500
500
500
500
400
400
400
400
20
20
20
20
20
20
20
20
10 000
10 000
10 000
10 000
50
32
Yes
50
32
Yes
50
32
Yes
50
32
Yes
Alarms, report (shift report),
color print, hardcopy
Alarms, report (shift report),
color print, hardcopy
Alarms, report (shift report),
color print, hardcopy
Alarms, report (shift report),
color print, hardcopy,
PROFINET
MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition
MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition
MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition
MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition
• S7-1200
• S7-1500
S5, S7-200, S7-300/400,
TI 505, Win AC, PC (TCP/IP),
SINUMERIK, SIMOTION,
Allen Bradley (DF1), Allen
Bradley (DF485), Mitsubishi
(FX), OMRON (LINK/Multilink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes
S5, S7-200, S7- 300/400,
TI 505, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes
S5, S7-200, S7- 300/400,
TI 505, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes
S5, S7-200, S7- 300/400,
TI 505, Win AC, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes
I/O
I/O devices
• Multi Media Card
Printer, barcode reader
Yes
Printer, barcode reader
Yes
Printer, barcode reader
Yes
Printer, barcode reader
Yes
Mechanics/material
Type of housing (front)
Plastic
Plastic
Plastic
Plastic
Dimensions
Housing diameter/depth (mm)
Dia 290 mm / D 103 mm
Dia 290 mm / D 103 mm
Dia 290 mm / D 103 mm
Weight
Weight
1.7 kg
1.7 kg
1.7 kg
Lists
• Number of text lists per
project
• Number of graphics lists per
project
Archiving
• Number of archives per
device
• Number of measuring points
per project
• Number of entries per archive
Security
• Number of user groups
• Number of user rights
• Password export/import
Logging through printer
• Recording/Printing
Transfer (upload/download)
• Transfer of configuration
Process coupling
• Connection to controller
2
2.3 kg
Siemens ST 80 / ST PC · 2013
2/55
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
■ Ordering data
SIMATIC Mobile Panel 277 10"
• With integrated acknowledgement
button and STOP button
Order No.
6AV6645-0CA01-0AX0
■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
6AV6645-0CB01-0AX0
6AV6645-0CC01-0AX0
8°
6AV6645-0BE02-0AX0
Documentation
9
155
6AV6691-1SA01-0AX0
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available user
manuals, device manuals and
communication manuals for
SIMATIC HMI
103
Ø 290
129
System components
for Mobile Panels
DP connection box for
Mobile Panels (MPI/PROFIBUS)
• Basic
• Plus
6AV6671-5AE00-0AX0
6AV6671-5AE10-0AX0
PN connection box for
Mobile Panel (PROFINET)
• Basic
• Plus
6AV6671-5AE01-0AX0
6AV6671-5AE11-0AX0
Connecting cable and
accessories for Mobile Panels
See HMI accessories,
from page 2/99
G_ST80_XX_00277
SIMATIC HMI Manual Collection
Electronic documentation, on DVD
117
You can find the manuals for the
Mobile Panels on the Internet at:
http://support.automation.siemens.com/WW/view/en/11599011/
133300
Mobile Panel 277 8", front and side view
1)
The system components (connecting cables and connection boxes) must
be ordered separately.
2)
Delivery time approximately 6 weeks
320
8°
212
159
103
350
129
G_ST80_XX_00354
2
SIMATIC Mobile Panel 277 8" 1)
• With integrated acknowledgement
button
• With integrated acknowledgement
button and STOP button
• With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and two illuminated pushbuttons
Mobile Panel 277 10", front and side view
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
2/56
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Overview
2
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications
6AV6645-0DD01-0AX1
6AV6645-0DE01-0AX1
6AV6645-0EB01-0AX1
6AV6645-0EC01-0AX1
6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
Display
Size
7.5"
7.5"
7.5"
7.5"
7.5"
Display type
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
640 x 480
640 x 480
640 x 480
640 x 480
about 50,000 hours
about 50,000 hours
about 50,000 hours
about 50,000 hours
about 50,000 hours
50 000 h
50 000 h
50 000 h
50 000 h
50 000 h
Control elements
Operating options
Keys and Touch
Keys and Touch
Keys and Touch
Keys and Touch
Keys and Touch
Function keys,
programmable
18 function keys,
18 with LEDs
18 function keys,
18 with LEDs
18 function keys,
18 with LEDs
18 function keys,
18 with LEDs
18 function keys,
18 with LEDs
Connection for mouse/
keyboard/barcode reader
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
Analog, resistive
Analog, resistive
Analog, resistive
Analog, resistive
Analog, resistive
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Resolution (pixels)
• Resolution (WxH in pixel) 640 x 480
Backlighting
• MTBF backlighting
(at 25 °C)
• MTBF backlighting
(at 25 °C)
Touch operation
• Touch screen
Special operator controls
• Stop button
• Acknowledgement
button
• Key-operated switch
• Illuminated pushbutton
• Handwheel
Siemens ST 80 / ST PC · 2013
2/57
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
6AV6645-0DD01-0AX1
6AV6645-0DE01-0AX1
6AV6645-0EB01-0AX1
6AV6645-0EC01-0AX1
6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
2
Supply voltage
Supply voltage
DC
DC
DC
DC
DC
Via charging station
Yes
Yes
Yes
Yes
Yes
Via table power supply
Yes
Yes
Yes
Yes
Yes
Processor
Processor
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
Memory
Type
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Usable memory for user
data
6 MB usable memory
for user data
6 MB usable memory
for user data
6 MB usable memory
for user data
6 MB usable memory
for user data
6 MB usable memory
for user data
7.2 V
5 100 mA·h
500
7.2 V
5 100 mA·h
500
7.2 V
5 100 mA·h
500
7.2 V
5 100 mA·h
500
7.2 V
5 100 mA·h
500
4h
4h
Yes
4h
4h
Yes
4h
4h
Yes
4h
4h
Yes
4h
4h
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Battery
Main battery
• Rated voltage
• Capacity
• Number of loading
cycles, min
• Charging time, typ.
• Operating time, typ.
• Display for battery
capacity
• Energy-saving mode
• Battery replacement
during operation
Type of output
Status LEDs
LED for safe
LED for communication
Yes
Yes
Yes
Yes
Yes
LED for battery
Yes
Yes
Yes
Yes
Yes
Vibrations
Yes
Yes
Yes
Yes
Yes
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Interfaces
Interfaces
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
USB port
1 x USB
1 x USB
1 x USB
1 x USB
1 x USB
Multi Media Card slot
1 MMC/SD card slot
1 MMC/SD card slot
1 MMC/SD card slot
1 MMC/SD card slot
1 MMC/SD card slot
Industrial Ethernet
• Industrial Ethernet
interface
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
WLAN
• Wireless LAN
• Supports rapid roaming
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Protocols
PROFINET
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Time of day
Clock
• Type
Supports protocol for
PROFINET IO
Supports protocol for
PROFIsafe
2/58
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
6AV6645-0DD01-0AX1
EMC
Emission of radio interference acc. to EN 55 011
• Emission of radio
interferences acc. to
EN 55 011 (limit class A)
6AV6645-0DE01-0AX1
6AV6645-0EB01-0AX1
6AV6645-0EC01-0AX1
6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Degree and class of
protection
IP65 enclosure
Yes
Yes
Yes
Yes
Yes
Standards, approvals,
certificates
Certifications
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
TÜV safety certification
Yes
Yes
Yes
Safety category according
to EN954-1
Safety category according to EN954-1
(enabling button, STOP
button if present) 4
Safety category according to EN954-1
(enabling button, STOP
button if present) 4
Safety category according to EN954-1
(enabling button, STOP
button if present) 4
e
e
e
Highest safety class
achievable in safety mode
• Performance Level in
accordance with
EN ISO 13849-1
Ambient conditions
Drop height
1.2 m
1.2 m
1.2 m
1.2 m
1.2 m
Operating temperature
• Operation
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
Storage/transport
temperature
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Relative humidity
• max. relative humidity
80 %
80 %
80 %
80 %
80 %
Operating systems
Operating system
Windows CE
Windows CE
Windows CE
Windows CE
Windows CE
16
16
16
16
16
Functionality under
WinCC (TIA Portal)
Libraries
Yes
Yes
Yes
Yes
Yes
Task planner
Yes
Yes
Yes
Yes
Yes
With alarm logging system
(incl. buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages
4 000
Yes
Yes
4 000
Yes
Yes
4 000
Yes
Yes
4 000
Yes
Yes
4 000
Yes
Yes
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
Languages
Online languages
• Number of online/runtime languages
Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory
Siemens ST 80 / ST PC · 2013
2/59
2
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
6AV6645-0DD01-0AX1
6AV6645-0DE01-0AX1
6AV6645-0EB01-0AX1
6AV6645-0EC01-0AX1
6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
2 048
2 048
2 048
2 048
2 048
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
500
500
500
500
500
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
500
500
500
500
500
400
400
400
400
400
20
20
20
20
20
20
20
20
20
20
10 000
10 000
10 000
10 000
10 000
50
32
Yes
50
32
Yes
50
32
Yes
50
32
Yes
50
32
Yes
Alarms, report (shift
report), PROFINET
Alarms, report (shift
report), PROFINET
Alarms, report (shift
report), PROFINET
Alarms, report (shift
report), PROFINET
Alarms, report (shift
report), PROFINET
USB, Ethernet, automatic transfer recognition
Yes
USB, Ethernet, automatic transfer recognition
Yes
USB, Ethernet, automatic transfer recognition
Yes
USB, Ethernet, automatic transfer recognition
Yes
USB, Ethernet, automatic transfer recognition
Yes
2
Variables
• Number of variables
per device
• Limit values
• Multiplexing
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects
Lists
• Number of text lists
per project
• Number of graphics lists
per project
Archiving
• Number of archives
per device
• Number of measuring
points per project
• Number of entries
per archive
Security
• Number of user groups
• Number of user rights
• Password export/import
Logging through printer
• Recording/Printing
Transfer
(upload/download)
• Transfer of configuration
• Wireless LAN
2/60
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
6AV6645-0DD01-0AX1
Process coupling
• Connection to controller
• S7-1200
• S7-1500
• Zones
- Number of zones
per project, max.
- Number of transponders for zones per
project, max.
• Effective range
- Number of effective
ranges per project,
max.
- Number of
transponders for
effective ranges per
project, max.
• Transponder
- Number of transponders per project, max.
- Adjustable distance
range
- Adjustable distance,
min.
- Adjustable distance,
max.
6AV6645-0DE01-0AX1
6AV6645-0EB01-0AX1
6AV6645-0EC01-0AX1
6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
S7-200, S7- 300/400
see section on "System
interfaces"
No
No
S7-200, S7- 300/400
see section on "System
interfaces"
Yes
Yes
Yes
254
S7-200, S7- 300/400
see section on "System
interfaces"
Yes
Yes
Yes
254
S7-200, S7- 300/400
see section on "System
interfaces"
No
No
Yes
254
S7-200, S7- 300/400
see section on "System
interfaces"
No
No
Yes
254
255
255
255
255
Yes
127
Yes
127
127
127
Yes
127
Yes
256
Yes
256
Yes
256
Yes
256
Yes
Yes
Yes
Yes
2m
2m
2m
2m
8m
8m
8m
8m
I/O
I/O devices
• Multi Media Card
Barcode reader
Yes
Barcode reader
Yes
Barcode reader
Yes
Barcode reader
Yes
Barcode reader
Yes
Mechanics/material
Type of housing (front)
Plastic
Plastic
Plastic
Plastic
Plastic
Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm
Dia 290 mm / D 103 mm
Dia 290 mm / D 103 mm
Dia 290 mm / D 103 mm
2.2 kg
2.2 kg
2.2 kg
2.2 kg
Dimensions
Housing diameter/depth
(mm)
Weight
Weight
2.2 kg
Siemens ST 80 / ST PC · 2013
2/61
2
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
6AV6645-0FD01-0AX1
6AV6645-0FE01-0AX1
6AV6645-0GB01-0AX1
6AV6645-0GC01-0AX1
6AV6645-0GF01-0AX1
USA version
USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
Display
Size
7.5"
7.5"
7.5"
7.5"
7.5"
Display type
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
TFT, 65536 colors
640 x 480
640 x 480
640 x 480
640 x 480
about 50,000 hours
about 50,000 hours
about 50,000 hours
about 50,000 hours
50 000 h
50 000 h
50 000 h
2
Resolution (pixels)
• Resolution (WxH in pixel) 640 x 480
Backlighting
• MTBF backlighting
(at 25 °C)
• MTBF backlighting
(at 25 °C)
about 50,000 hours
50 000 h
Control elements
Operating options
Keys and Touch
Keys and Touch
Keys and Touch
Keys and Touch
Keys and Touch
Function keys,
programmable
18 function keys,
18 with LEDs
18 function keys,
18 with LEDs
18 function keys,
18 with LEDs
18 function keys,
18 with LEDs
18 function keys,
18 with LEDs
Connection for mouse/
keyboard/barcode reader
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
USB / USB / USB
Analog, resistive
Analog, resistive
Analog, resistive
Analog, resistive
Analog, resistive
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Supply voltage
Supply voltage
DC
DC
DC
DC
DC
Via charging station
Yes
Yes
Yes
Yes
Yes
Via table power supply
Yes
Yes
Yes
Yes
Yes
Processor
Processor
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
ARM, 520 MHz
Memory
Type
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Flash / RAM
Usable memory for user
data
6 MB usable memory
for user data
6 MB usable memory
for user data
6 MB usable memory
for user data
6 MB usable memory
for user data
6 MB usable memory
for user data
7.2 V
5 100 mA·h
500
7.2 V
5 100 mA·h
500
7.2 V
5 100 mA·h
500
7.2 V
5 100 mA·h
500
7.2 V
5 100 mA·h
500
4h
4h
Yes
4h
4h
Yes
4h
4h
Yes
4h
4h
Yes
4h
4h
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Touch operation
• Touch screen
Special operator controls
• Stop button
• Acknowledgement
button
• Key-operated switch
• Illuminated pushbutton
• Handwheel
Battery
Main battery
• Rated voltage
• Capacity
• Number of loading
cycles, min
• Charging time, typ.
• Operating time, typ.
• Display for battery
capacity
• Energy-saving mode
• Battery replacement
during operation
2/62
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
Type of output
Status LEDs
6AV6645-0FD01-0AX1
6AV6645-0FE01-0AX1
6AV6645-0GB01-0AX1
6AV6645-0GC01-0AX1
6AV6645-0GF01-0AX1
USA version
USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
LED for safe
LED for communication
Yes
Yes
Yes
Yes
Yes
LED for battery
Yes
Yes
Yes
Yes
Yes
Vibrations
Yes
Yes
Yes
Yes
Yes
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Hardware clock, battery
backup, synchronizable
Interfaces
Interfaces
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
USB port
1 x USB
1 x USB
1 x USB
1 x USB
1 x USB
Multi Media Card slot
1 MMC/SD card slot
1 MMC/SD card slot
1 MMC/SD card slot
1 MMC/SD card slot
1 MMC/SD card slot
Industrial Ethernet
• Industrial Ethernet
interface
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
1 x Ethernet (RJ45)
WLAN
• Wireless LAN
• Supports rapid roaming
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Protocols
PROFINET
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Time of day
Clock
• Type
Supports protocol for
PROFINET IO
Supports protocol for
PROFIsafe
EMC
Emission of radio interference acc. to EN 55 011
• Emission of radio
interferences acc. to
EN 55 011 (limit class A)
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Siemens ST 80 / ST PC · 2013
2/63
2
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
6AV6645-0FD01-0AX1
6AV6645-0FE01-0AX1
6AV6645-0GB01-0AX1
6AV6645-0GC01-0AX1
6AV6645-0GF01-0AX1
USA version
USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
Degree and class of
protection
IP65 enclosure
Yes
Yes
Yes
Yes
Yes
Standards, approvals,
certificates
Certifications
CE, cULus, C-TICK
CE, cULus, C-TICK
2
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
TÜV safety certification
Yes
Yes
Yes
Safety category according
to EN954-1
Safety category
according to EN954-1
(enabling button, STOP
button if present) 4
Safety category
according to EN954-1
(enabling button, STOP
button if present) 4
Safety category
according to EN954-1
(enabling button, STOP
button if present) 4
e
e
e
Highest safety class
achievable in safety mode
• Performance Level in
accordance with
EN ISO 13849-1
Ambient conditions
Drop height
1.2 m
1.2 m
1.2 m
1.2 m
1.2 m
Operating temperature
• Operation
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
0 °C to +40 °C
Storage/transport temperature
• Transport, storage
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
-20 °C to +60 °C
Relative humidity
• max. relative humidity
80 %
80 %
80 %
80 %
80 %
Operating systems
Operating system
Windows CE
Windows CE
Windows CE
Windows CE
Windows CE
16
16
16
16
16
Functionality under
WinCC (TIA Portal)
Libraries
Yes
Yes
Yes
Yes
Yes
Task planner
Yes
Yes
Yes
Yes
Yes
With alarm logging system
(incl. buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages
4 000
Yes
Yes
4 000
Yes
Yes
4 000
Yes
Yes
4 000
Yes
Yes
4 000
Yes
Yes
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
300
500
1 000
64 KB integrated Flash,
expandable
Languages
Online languages
• Number of online/
runtime languages
Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory
2/64
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
Variables
• Number of variables per
device
• Limit values
• Multiplexing
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects
Lists
• Number of text lists per
project
• Number of graphics lists
per project
Archiving
• Number of archives per
device
• Number of measuring
points per project
• Number of entries per
archive
Security
• Number of user groups
• Number of user rights
• Password export/import
Logging through printer
• Recording/Printing
Transfer
(upload/download)
• Transfer of configuration
• Wireless LAN
6AV6645-0FD01-0AX1
6AV6645-0FE01-0AX1
6AV6645-0GB01-0AX1
6AV6645-0GC01-0AX1
6AV6645-0GF01-0AX1
USA version
USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
2 048
2 048
2 048
2 048
2 048
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
500
500
500
500
500
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
10,000 text elements
Bit maps, icons, vector
graphics
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
500
500
500
500
500
400
400
400
400
400
20
20
20
20
20
20
20
20
20
20
10 000
10 000
10 000
10 000
10 000
50
32
Yes
50
32
Yes
50
32
Yes
50
32
Yes
50
32
Yes
Alarms, report (shift
report), PROFINET
Alarms, report (shift
report), PROFINET
Alarms, report (shift
report), PROFINET
Alarms, report (shift
report), PROFINET
Alarms, report (shift
report), PROFINET
USB, Ethernet, automatic transfer recognition
Yes
USB, Ethernet, automatic transfer recognition
Yes
USB, Ethernet, automatic transfer recognition
Yes
USB, Ethernet, automatic transfer recognition
Yes
USB, Ethernet, automatic transfer recognition
Yes
Siemens ST 80 / ST PC · 2013
2/65
2
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Technical specifications (continued)
6AV6645-0FD01-0AX1
6AV6645-0FE01-0AX1
6AV6645-0GB01-0AX1
6AV6645-0GC01-0AX1
6AV6645-0GF01-0AX1
USA version
USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
S7-200, S7- 300/400
see section on "System
interfaces"
Yes
Yes
Yes
254
S7-200, S7- 300/400
see section on "System
interfaces"
Yes
Yes
Yes
254
S7-200, S7- 300/400
see section on "System
interfaces"
No
No
Yes
254
S7-200, S7- 300/400
see section on "System
interfaces"
No
No
Yes
254
S7-200, S7- 300/400
see section on "System
interfaces"
No
No
255
255
255
255
Yes
127
Yes
127
127
127
2
Process coupling
• Connection to controller
• S7-1200
• S7-1500
• Zones
- Number of zones per
project, max.
- Number of
transponders for zones
per project, max.
• Effective range
- Number of effective
ranges per project,
max.
- Number of
transponders for
effective ranges per
project, max.
• Transponder
- Number of transponders per project, max.
- Adjustable distance
range
- Adjustable distance,
min.
- Adjustable distance,
max.
Yes
127
Yes
256
Yes
256
Yes
256
Yes
256
Yes
Yes
Yes
Yes
2m
2m
2m
2m
8m
8m
8m
8m
I/O
I/O devices
• Multi Media Card
Barcode reader
Yes
Barcode reader
Yes
Barcode reader
Yes
Barcode reader
Yes
Barcode reader
Yes
Mechanics/material
Type of housing (front)
Plastic
Plastic
Plastic
Plastic
Plastic
Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm
Dia 290 mm / D 103 mm
Dia 290 mm / D 103 mm
Dia 290 mm / D 103 mm
2.2 kg
2.2 kg
2.2 kg
2.2 kg
Dimensions
Housing diameter/depth
(mm)
Weight
Weight
2/66
Siemens ST 80 / ST PC · 2013
2.2 kg
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Ordering data
SIMATIC Mobile Panel 277
IWLAN V2 (RoW version 1))
• Communication via WLAN
(PROFINET)
• Communication via WLAN
(PROFINET)
with integrated handwheel,
key-operated switch and
two illuminated pushbuttons
SIMATIC Mobile Panel 277F
IWLAN V2 PROFIsafe
(RoW version 1))
• Communication via WLAN
(PROFINET)
with acknowledgement button and
emergency stop button
• Communication via WLAN
(PROFINET)
with acknowledgement button and
emergency stop button with integrated handwheel, key-operated
switch, and two illuminated pushbuttons
• RFID tag version: Communication
via WLAN (PROFINET) with acknowledgement button and emergency stop button with integrated
handwheel, key-operated switch,
and two illuminated pushbuttons
SIMATIC Mobile Panel 277
IWLAN V2 (USA version)
• Communication via WLAN
(PROFINET)
• Communication via WLAN
(PROFINET)
with integrated handwheel,
key-operated switch and
two illuminated pushbuttons
SIMATIC Mobile Panel 277F
IWLAN V2 PROFIsafe
(USA version)
• with acknowledgement button and
emergency stop button
• with acknowledgement button and
emergency stop button with integrated handwheel, key-operated
switch, and two illuminated pushbuttons
• with acknowledgement button and
emergency stop button with integrated handwheel, key-operated
switch, and two illuminated pushbuttons (tag version)
Order No.
Order No.
See HMI accessories,
from page 2/99
Accessories
6AV6645-0DD01-0AX1
6AV6645-0DE01-0AX1
Note:
Please order the table-top power
supply or charging station as well.
Required for charging the battery.
Documentation
2
You can find the manuals for the
Mobile Panels on the Internet at:
6AV6645-0EB01-0AX1
http://support.automation.siemens.com/WW/view/en/11599011/
133300
SIMATIC HMI Manual Collection
6AV6645-0EC01-0AX1
6AV6691-1SA01-0AX0
Electronic documentation on DVD,
5 languages (English, German,
French, Italian and Spanish);
contains: all currently available user
manuals, device manuals and communication manuals for
SIMATIC HMI
6AV6645-0EF01-0AX1
6AV6645-0FD01-0AX1
6AV6645-0FE01-0AX1
6AV6645-0GB01-0AX1
6AV6645-0GC01-0AX1
6AV6645-0GF01-0AX1
Starter kit
SIMATIC Mobile Panel 277(F)
IWLAN (RoW version1))
for
• Mobile Panel 277 IWLAN V2
• Mobile Panel 277F IWLAN V2
6AV6651-5GA01-0AA1
6AV6651-5HA01-0AA1
1)
2)
RoW version: "Rest of World" version:
Version for worldwide sales except in the U.S.
Already prepared for Rapid Roaming (iPCF-MC). iPCF-MC is already
included from SCALANCE FW version V4.3.37 and higher.
For national approvals see:
http://www.siemens.com/wireless-approvals
The Function Manuals "Fail-Safe Operation of the Mobile Panel
277F IWLAN V1" are available for downloading in English,
German, and Japanese.
http://support.automation.siemens.com/WW/view/en/31255853
Siemens ST 80 / ST PC · 2013
2/67
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
■ Dimensional drawings
■ More information
All dimensions in mm. For installation cutout, see technical
specifications.
Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels
Note
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, you will find information on ordering additional
and standard industry products as well as possibilities for
customer-specific modifications and adjustments.
8°
ø 290 mm
Mobile Panel 277(F) IWLAN, front and side view
2/68
Siemens ST 80 / ST PC · 2013
103 mm
129 mm
G_ST80_XX_00299
155
117
9
2
© Siemens AG 2013
Operator panels
System components
System components for Mobile Panels
■ Overview
System components for Mobile Panels are perfectly matched
to the SIMATIC HMI Mobile Panels. Charging stations,
transponders, and diverse connection boxes are available for
various applications.
Accessories for SIMATIC HMI Mobile Panels can be found under
"SIMATIC HMI accessories".
Only the latest SIMATIC HMI accessories are listed in this
section; the full range of SIMATIC HMI accessories is available
in the Mall and in our other online media.
Siemens ST 80 / ST PC · 2013
2/69
2
© Siemens AG 2013
Operator panels
System components
Terminal boxes
■ Overview
2
■ Technical specifications
6AV6671-5AE00-0AX0
6AV6671-5AE10-0AX0
6AV6671-5AE01-0AX0
6AV6671-5AE11-0AX0
DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Basic
DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Plus
PN connection box for
Mobile Panel 177/277
(PROFINET) Basic
PN connection box for
Mobile Panel 177/277
(PROFINET) Plus
with emergency stop circuit
interruption
No
without emergency stop
circuit interruption
Yes
with emergency stop circuit
interruption
No
without emergency stop
circuit interruption
Yes
Yes
No
Yes
No
No
Yes
Yes
Yes
No
Yes
Yes
Yes
Supply voltage
Type of actuation
• AC
• DC
DC
No
Yes
DC
No
Yes
DC
No
Yes
DC
No
Yes
Rated voltage
24 V
24 V
24 V
24 V
permissible range
• Supply voltage range
• Supply voltage range
+20.4 V to +28.8 V DC
20.4 V
28.8 V
+20.4 V to +28.8 V DC
20.4 V
28.8 V
+20.4 V to +28.8 V DC
20.4 V
28.8 V
+20.4 V to +28.8 V DC
20.4 V
28.8 V
Supply voltage
24 V DC
24 V DC
24 V DC
24 V DC
Input current
Rated current
0.4 A
0.5 A
0.4 A
0.5 A
Power
Power
10 W
12 W
10 W
12 W
1 x RS232, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)
1 x RS232, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)
2 x Ethernet (RJ45)
2 x Ethernet (RJ45)
Number of 20 mA interfaces
(TTY)
0
0
Number of RS 232 interfaces
1
1
Number of RS 422 interfaces
1
1
2 x Ethernet (RJ45)
6
2 x Ethernet (RJ45)
6
Control elements
Expansions for operator control
of the process
• Hot swapping
- without emergency stop
circuit interruption
- with emergency stop circuit
interruption
- Monitoring the STOP button
- Location identifier
Interfaces
Interfaces
Industrial Ethernet
• Industrial Ethernet interface
• Industrial Ethernet status LED
2/70
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
System components
Terminal boxes
■ Technical specifications (continued)
6AV6671-5AE00-0AX0
6AV6671-5AE10-0AX0
6AV6671-5AE01-0AX0
6AV6671-5AE11-0AX0
DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Basic
DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Plus
PN connection box for
Mobile Panel 177/277
(PROFINET) Basic
PN connection box for
Mobile Panel 177/277
(PROFINET) Plus
IP65
IP65
IP65
IP65
IP20 housing
No
No
No
No
IP54 housing
No
No
No
No
IP65 enclosure
Yes
Yes
Yes
Yes
NEMA 4
No
No
No
No
NEMA 4X
No
No
No
No
NEMA 12
No
No
No
No
Standards, approvals,
certificates
Certifications
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
CE, cULus, C-TICK
CE
Yes
Yes
Yes
Yes
CSA
No
No
No
No
UL
No
No
No
No
FM Class I Div. 2
No
No
No
No
GL
No
No
No
No
ABS
No
No
No
No
BV
No
No
No
No
DNV
No
No
No
No
LRS
No
No
No
No
PRS
No
No
No
No
Gost-R
No
No
No
No
Use in hazardous areas
• EX zone 2
• EX zone 22
No
No
No
No
No
No
No
No
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
0 °C to +50 °C
0 °C
0 °C
0 °C
0 °C
50 °C
50 °C
50 °C
50 °C
-20 °C
-20 °C
-20 °C
-20 °C
70 °C
70 °C
70 °C
70 °C
-20 °C to +70 °C
-20 °C to +70 °C
-20 °C to +70 °C
-20 °C to +70 °C
85 %
85 %
85 %
85 %
Yes
Yes
Yes
Yes
160 x 120 x 70
160 x 120 x 70
230 x 120 x 80
230 x 120 x 80
160
120
70
160
120
70
230
120
80
230
120
80
Weight
Weight
0.35 kg
0.4 kg
0.45 kg
0.5 kg
other
free hotline
Yes
Yes
Yes
Yes
Warranty period
1a
1a
1a
1a
Degree and class of
protection
Enclosure according to
EN 60529
Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Storage/transport temperature
• Ambient temperature
during storage, minimum
• Ambient temperature
during storage, maximal
• Transport, storage
Relative humidity
• max. relative humidity
Functionality under WinCC
(TIA Portal)
Applications/options
• Connection point
identification
Dimensions
External dimensions
(W x H x D) in mm
• Width
• Height
• Depth
Siemens ST 80 / ST PC · 2013
2
2/71
© Siemens AG 2013
Operator panels
System components
Terminal boxes
■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
6AV6671-5AE00-0AX0
6AV6671-5AE10-0AX0
6AV6671-5AE01-0AX0
6AV6671-5AE11-0AX0
62.7
140
G_ST80_XX_00045
11 0
120
142 ± 2
160
150
DP connection box for SIMATIC Mobile Panel
230
55
110
120
142 ± 2
220
4.5
PN connection box for SIMATIC Mobile Panel
2/72
Siemens ST 80 / ST PC · 2013
G_ST80_XX_00273
76
210
10
2
PN connection box
for Mobile Panels 177/277
(PROFINET)
• Basic
• Plus
Order No.
43
DP connection box
for Mobile Panels 177/277
(MPI/PROFIBUS)
• Basic
• Plus
10
■ Ordering data
© Siemens AG 2013
Operator panels
System components
SIPLUS connection boxes
■ Overview
■ Ordering data
Order No.
SIPLUS connection box DP Plus
for Mobile Panels 177/277
(MPI/PROFIBUS)
6AG1671-5AE10-4AX0
2
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific information was added.
SIPLUS connection box DP Plus
Order number
6AG1 671-5AE10-4AX0
Order number based on
6AV6 671-5AE10-0AX0
Ambient temperature range
0 ... +50 °C
Conformal coating
Coating of the printed circuit boards
and the electronic components
Technical data
The technical data of the standard
product applies except for the
ambient conditions.
Ambient conditions
Relative humidity
100%, condensation/frost
permissible. No commissioning
if condensation present.
Air pressure
(depending on the highest positive
temperature range specified)
1080 ... 795 hPa (-1000 ... +2000m)
see ambient temperature range
795 ... 658 hPa (+2000 ... +3500m)
derating 10 K
658 … 540 hPa (+3500 … +5000m)
derating 20 K
Siemens ST 80 / ST PC · 2013
2/73
© Siemens AG 2013
Operator panels
System components
Charging station
■ Overview
■ Ordering data
Order No.
Charging station for
Mobile Panels
6AV6671-5CE00-0AX1
■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
85
2
160
24 V
permissible range
• Supply voltage range
• Supply voltage range
+19.2 V to +28.8 V DC
19.2 V
28.8 V
Supply voltage
24 V DC
Input current
Rated current
3.2 A
Power
Power
77 W
Degree and class of protection
Enclosure according to EN 60529
IP65
IP65 enclosure
Yes
Standards, approvals, certificates
Certifications
CE, cULus, C-TICK
CE
Yes
Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
0 °C to +40 °C
0 °C
208
Storage/transport temperature
• Ambient temperature during storage,
minimum
• Ambient temperature during storage,
maximal
• Transport, storage
Relative humidity
• max. relative humidity
Dimensions
External dimensions
(W x H x D) in mm
• Width
• Height
• Depth
Weight
Weight
2/74
40 °C
-20 °C
60 °C
-20 °C to +60 °C
85 %
208 x 333 x 75
208
333
75
1.1 kg
Siemens ST 80 / ST PC · 2013
72
G_ST80_XX_00297
Rated voltage
198
DC
Yes
61
6AV6671-5CE00-0AX1
Supply voltage
Type of actuation
• DC
343
■ Technical specifications
© Siemens AG 2013
Operator panels
System components
Transponder
■ Overview
■ Ordering data
Order No.
Transponder for
Mobile Panels 277
6AV6671-5CM00-0AX1
■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
45
90
2
38.5
■ Technical specifications
6AV6671-5CM00-0AX1
Degree and class of protection
Enclosure according to EN 60529
IP65
IP65 enclosure
Yes
Enclosure according to NEMA
NEMA 4x, NEMA 12
NEMA 4X
Yes
NEMA 12
Yes
Standards, approvals, certificates
Certifications
CE, cULus, C-TICK, NEMA 4x,
NEMA 12
CE
Yes
Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
0 °C to +50 °C
0 °C
Storage/transport temperature
• Ambient temperature during storage,
minimum
• Ambient temperature during storage,
maximal
• Transport, storage
Relative humidity
• max. relative humidity
Dimensions
External dimensions
(W x H x D) in mm
• Width
• Height
• Depth
Weight
Weight
172
G_ST80_XX_00298
162
50 °C
-20 °C
60 °C
-20 °C to +60 °C
85 %
172 x 90 x 38.5
172
90
38.5
0.3 kg
Siemens ST 80 / ST PC · 2013
2/75
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
System interfaces with WinCC (TIA Portal)
■ Overview
2
The SIMATIC Touch Panel (TP), Operator Panel (OP),
Basic Panel, Comfort Panel, Mobile Panel, multifunctional
platforms (MP)1) offer HMI functionality for the control systems:
• SIMATIC S7
• Non-Siemens controllers:
- Allen Bradley
- Mitsubishi
- Modicon
- Omron
For more detailed information, refer to the WinCC (TIA Portal)
user manual, the "Windows-based systems communication"
manual, or the WinCC (TIA Portal) online help.
OPC communication and HTTP communication are offered for all
Panels with an integrated Ethernet interface. Both OPC and
HTTP communication can be used in parallel with the process
links to SIMATIC S7 or non-Siemens PLCs.
1)
Note:
Interface options for HMI devices: See the individual device
descriptions.
OPC communication
OPC Data Access is an open standard for exchanging both local
and remote variables between various applications via Industrial
Ethernet. The original version of OPC is based on Microsoft
COM/DCOM and, therefore, requires a Microsoft Windowsbased PC operating system (not Windows CE) on both clients
and servers. As OPC XML, communication is based on the
Internet standard SOAP/XML and is, therefore, suitable for
embedded systems with Windows CE.
HTTP communication for variable exchange between
SIMATIC HMI systems
Communication based on HTTP message frames enables
variables to be exchanged between SIMATIC HMI systems.
For the sake of simplicity, SIMATIC Panel is always used in the text below.
This is not restrictive, as the information is valid for all systems referred to
above. If there are constraints, direct reference is made to them in the text.
Communication standard
SIMATIC HMI
Version
Comfort Panel
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 PN
MP 177
TP 277
OP 277
Mobile Panel 277
MP 277
MP 377
WinCC Runtime
Advanced
OPC Data Access V2.05a + OPC UA Data Access V1.01 + OPC Data Access XML V1.00
OPC DA Client
(COM/DCOM)
–
–
–
–
•
OPC DA server
(COM/DCOM)
–
–
–
–
•
OPC UA client
•
–
–
–
•
OPC XML DA client
(SOAP/XML)
–
–
–
–
• 1)
OPC XML DA server
(SOAP/XML)
•
–
–
•
–
HTTP communication for variable exchange between SIMATIC HMI systems
HTTP client
•
•
•
•
•
HTTP server
•
•
•
•
•
• System interface possible
– System interface not possible
1)
Only through DCOM/XML gateway in scope of delivery of
WinCC Advanced for access to OPC XML server of the SIMATIC Panel
2/76
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
SIMATIC S7
■ Overview
The following types of interface are differentiated in respect of
the link between the SIMATIC Panels and SIMATIC S7
controllers:
• PROFINET interface:
Coupling of SIMATIC Panel to SIMATIC S7 controllers via
Industrial Ethernet TCP/IP using the integrated PROFINET
interface of the CPU or, alternatively, a PROFINET interface
module.
• MPI/PROFIBUS interface:
Coupling of SIMATIC Panel to SIMATIC S7 controllers via MPI/
PROFIBUS using the integrated MPI/PROFIBUS interface of
the CPU for S7-300, S7-400 or the integrated PPI interface of
the CPU in the case of S7-200 or, alternatively, a PROFIBUS
interface module in the case of S7-1200, S7-300 and S7-400.
• PPI interface:
Coupling of SIMATIC Panel to SIMATIC S7-200 via PPI network
using the integrated PPI interface of the CPU
PPI interface
The maximum possible number of S7 connections of one CPU is
determined by its performance capacity (see Catalog ST 70);
from the point of view of SIMATIC Panel, the following restrictions
apply:
• OP 73: max. 2 connections
• OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B,
Mobile Panel 177: max. 4 connections
• Comfort Panel, TP 277, OP 277; Mobile Panel 277, MP 177,
MP 277, MP 377: max. 6 connections
• PC with WinCC Runtime Advanced: max. 8 connections
The original format of a master/master link has been joined by a
master/slave link, which has enabled integration of the S7-200
(except CPU 212).1)
The PPI interface is a point-to-point connection between a
SIMATIC Panel (PPI master) or alternatively a PG (PPI master)
and an S7-200 (PPI slave).
The corresponding multipoint-enabled communication interfaces of SIMATIC Panels and SIMATIC S7 are used.
The following are possible:
• Interface between one or a number of SIMATIC Panels (MPI
master) and one or a number of S7-1200/300/400s or WinAC
(MPI master).(possible network topology: MPI/PROFIBUS or
Industrial Ethernet, TCP/IP)
• Interface between one or a number of SIMATIC Panels
(MPI master) and one or a number of S7-200s (MPI slave)1)
(possible network topology: PPI, MPI/PROFIBUS)
Unlike PPI connections, MPI connections are static connections
that are set up during booting and then monitored.
In principle this type of information exchange between SIMATIC
Panels and SIMATIC S7 is independent of the network used, PPI,
MPI/PROFIBUS or Industrial Ethernet: SIMATIC Panels are
S7 clients and SIMATIC S7 CPUs are S7 servers.
1)
With regard to restricted baud transmission rates for S7-200,
see Catalog ST 70.
Siemens ST 80 / ST PC · 2013
2/77
2
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
SIMATIC S7
■ Overview (continued)
2
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 73
OP 77A
TP 177A
Basic Panel
Comfort Panel
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
via Ethernet (TCP/IP)
to max. 4 x S7-1200
–
• 5)
•
• 5)
•
•
via MPI or PROFIBUS network
to max. 4 x S7-1200 with
PROFIBUS module (DP-Master)
CM 1243-5
• 3) 4)
• 6)
•
•5)
•
• 7)
via Ethernet (TCP/IP)
to max. 4 x S7-300, -400,
WinAC
–
• 5)
•
• 5)
•
•
via MPI or PROFIBUS network
to up to 4 x S7-300, S7-400,
WinAC
• 3) 4)
• 6)
•
• 6)
•
• 7)
via Ethernet (TCP/IP)
(MPI protocol)
to max. 4 x S7-200
–
• 5)
•
• 5)
•
•
via MPI or PROFIBUS network
(MPI protocol)
to up to 4 x S7-200
• 3) 4)
• 6)
• 8)
• 6) 8)
• 8)
• 7) 8)
via PPI network
(MPI protocol)
to up to 4 x S7-200
• 3) 4)
• 6)
–
• 9)
–
–
via PPI network
(PPI protocol)
to max. 1 x S7-200
–
–
• 10)
• 10)
• 10)
• 7)10)
SIMATIC S7-1200 2)
SIMATIC S7-300, -400, Win AC 2)
SIMATIC S7-200 2)
• System interface possible
– System interface not possible
1)
Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2)
Controllers can be combined as desired
3)
OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI);
network operation (parallel PG, etc.) possible
4)
5)
Max. transmission rate 1.5 Mbit/s
Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
6)
Not Basic Panel PN, Mobile Panel 177 PN
7)
Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2
with a standard PC
8)
Only on passive S7-200; OP 77B also on active S7-200
9)
Only OP 77B
10)
Can be interfaced via PPI to max. 1 x S7-200 (PPI);
network operation (parallel PG, etc) is possible
2/78
Siemens ST 80 / ST PC · 2013
Note:
Detailed information regarding cable layout can be found in the
online help for WinCC.
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers
■ Overview
The SIMATIC Touch Panel (TP), Operator Panel (OP), Basic
Panel, Comfort Panel, Mobile Panel, multifunctional platforms
(MP) and the SIMATIC HMI software package for PC WinCC
Runtime Advanced support the following protocols for the linking
of control systems from other manufacturers:
• Allen Bradley
- Ethernet IP protocol
- DF1 protocol
• Mitsubishi
- MC TCP/IP protocol
- FX protocol
• Modicon
- Modbus TCP/IP protocol
- Modbus RTU protocol
• Omron
- Link/Multi-Link protocol
2
The following table contains more detailed information.
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
TP 177A
Basic Panel
Comfort Panel
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
–
• 3)
•
• 3)
•
•
• 4)
• 4) 5)
• 4)
• 4) 5)
• 4)
• 6)
• 4)
• 4) 5)
• 4)
• 4) 5)
• 4)
• 7)
• 4)
• 4) 5)
• 4)
• 4) 5)
• 4)
• 7) 8)
•
• 5)
•
• 5)
•
–
• 4)
• 4) 5)
• 4)
• 4) 5)
• 4)
• 7) 8)
Allen Bradley (Ethernet IP)
via Ethernet TCP/IP network
to max. 4 x controllers 2)
• ControlLogix 1756-L6x, -L6xS
with Ethernet module
1756-ENBT
• Guard Logix System
• CompactLogix 1769-L2xE,
-L3xE
• CompactLogix 1769-L4x with
ETHERNET module
1768-ENBT
• SLC 5/05
• MicroLogix 1100, 1400
Allen Bradley (DF1)
to max. 1 x controller
• SLC 5/03, /04, /05
• MicroLogix (RS 232)
to max. 1 x controller
• PLC5/11, /20, /30, /40, /60, /80
(RS 232)
via KF2 gateway and DH+ network to max. 4 x controllers 2)
• SLC 5/04
• PLC5/11, /20, /30, /40, /60, /80
(RS 232)
via KF2 gateway and DH+ network to max. 4 x controllers 2)
• SLC 5/04
• PLC5/11, /20, /30, /40, /60, /80
(RS 422)
via KF3 gateway and DH485
network to max.
4 x controllers 2)
• SLC 500
• MicroLogix (RS 232)
• System interface possible
– System interface not possible
1)
Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2)
The following listed controllers can be combined as required
3)
Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
4)
For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required
5)
Not Basic Panel PN, Mobile Panel 177 PN
6)
Connection via Allen Bradley PC cable 1747 CP3
7)
Connection via Allen Bradley PC cable 1784 CP10
8)
For connection to KF2/KF3 gateway, a gender-changer
(25-pin socket/25-pin socket) is required on the gateway side
Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071
Siemens ST 80 / ST PC · 2013
2/79
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers
■ Overview (continued)
2
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
TP 177A
Basic Panel
Comfort Panel
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
–
• 3)
•
• 3)
•
•
•
• 4)
•
• 4)
•
• 5)
Mitsubishi (MC TCP/IP)
via Ethernet IP network
to max. 4 x controllers 2)
• FX series FX3G, FX3U, FX3UC
with Ethernet module FX3U
ENET,
• Series Q with Ethernet module
QJ71E71-100
• iQ series/QnUD QnUDEH
Mitsubishi FX (serial)
to max. 1 x controller
FX series FX1N, FX2N (RS 232)
• System interface possible
– System interface not possible
1)
Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2)
The following listed controllers can be combined as required
3)
Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
Not Basic Panel PN, Mobile Panel 177 PN
4)
5)
Connection using a Mitsubishi PC cable SC-09 with integrated level
converter RS 232/RS 422
2/80
Siemens ST 80 / ST PC · 2013
Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
TP 177A
Basic Panel
Comfort Panel
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
3)
•
•
2
Modicon (MODBUS TCP/IP)
Via MODBUS TCP/IP network to
max. 4 x controllers 2)
• Concept Quantum,
Unity Quantum
• Momentum
• Premium (TSX57)
• TSX Micro (TSX37)
• Modicon M340 20x0
(except 2010)
Via TCP/IP Modbus Plus
Bridge 174 CEV 200 40 and
MODBUS PLUS network to
max. 4 x controllers 2)
• Concept Quantum,
Unity Quantum
• Momentum
• Compact
–
•
3)
•
•
–
• 3)
•
• 3)
•
•
• 4)
• 4) 5)
• 4)
• 4) 5)
• 4)
•
• 4)
• 4) 5)
• 4)
• 4) 5)
• 4)
•
Modicon (MODBUS RTU)
to max. 1 x controller
• Concept Quantum
• Momentum
• Compact
(RS 232)
Via bridge BM85-000 or PLC
with bridge functionality and
MODBUS PLUS network to
max. 4 x controllers 2)
• Concept Quantum
• Compact (RS 232)
• System interface possible
– System interface not possible
1)
Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2)
The following listed controllers can be combined as required
3)
Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
4)
For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required
5)
Not Basic Panel PN, Mobile Panel 177 PN
Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071
Siemens ST 80 / ST PC · 2013
2/81
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers
■ Overview (continued)
2
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
TP 177A
Basic Panel
Comfort Panel
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
–
–
• 3)
• 3) 4)
• 3)
•
–
–
• 3)
• 3) 4)
• 3)
•
•
• 4)
•
• 4)
• 4)
–
–
–
–
• 4)
• 4)
–
Omron (Link/MultiLink)
to max. 1 x controller
• CP1L, CP1H, CP1E
• CJ1M, CJ1H, CJ1G
• CJ2H
• CS1G, CS1H, CS1D
• CP2MC (RS 232)
via converter NT-AL001 and
RS 422 network to
max.4 x controllers 2)
• CP1L, CP1H, CP1E
• CJ1M, CJ1H, CJ1G
• CJ2H
• CS1G, CS1H, CS1D
• CP2MC (RS 232)
via RS 422 network to
max. 4 x controllers 2)
• CP1L, CP1H, CP1E
• CJ1M, CJ1H, CJ1G
(RS 422)
via RS422 network to
max. 4 x controllers 2)
• CJ2H
• CS1G, CS1H, CS1D
• CP2MC (RS 422)
• System interface possible
– System interface not possible
1)
2)
Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
The controllers listed below can be combined in any way required;
connection via RS 422 interface of the controller or via RS 422 module
3)
For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required
4)
Not Basic Panel PN, Mobile Panel 177 PN
2/82
Siemens ST 80 / ST PC · 2013
Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
System interfaces with WinCC flexible
■ Overview
SIMATIC Basic Panel, Touch Panels (TP), Operator Panels (OP),
Mobile Panel, Multifunctional Platforms (MP)1) and the SIMATIC
HMI software package for PC WinCC flexible Runtime support
HMI functionality in conjunction with:
• SIMATIC S7
• SIMATIC S5
• SIMATIC 505
• SIMOTION
• SINUMERIK 2)
• Non-Siemens controllers:
- Allen Bradley - DF1, DH485 and Ethernet IP protocols
- GE Fanuc - SNP/SNPX protocol
- LG GLOFA GM - dedicated protocol
- Mitsubishi - FX and MP 4 protocols
- Modicon - Modbus RTU and TCP/IP protocols
- Omron I - Link/MultiLink protocol
- Telemecanique - UNI-TELWAY protocol
Extended functionality with WinCC flexible
For more detailed information, refer to the WinCC flexible user
manual, the "Windows-based systems communication" manual,
and the WinCC flexible online help.
HTTP communication for the variable exchange between
SIMATIC HMI systems
(only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN,
TP 277, OP 277, Mobile Panel 277, Mobile Panel 277 IWLAN,
MP 277, MP 377, WinCC flexible Runtime)
1)
2)
For the sake of simplicity, SIMATIC TP/OP/MP is always used in the text
below. This is not restrictive, as the information is valid for all systems
referred to above. If there are constraints, direct reference is made to them
in the text.
Required under WinCC flexible: "SINUMERIK HMI copy license
WinCC flexible CE" and "SINUMERIK HMI copy license OA".
For configuring, a "SINUMERIK HMI engineering package WinCC flexible"
is also necessary.
WinCC flexible supports OPC communication for Multi Panel
and WinCC flexible Runtime and HTTP communication for all
panels with integrated Ethernet interface. Both OPC and HTTP
communication can be used in parallel with the process links to
SIMATIC S7/S5/505 or non-Siemens PLCs.
OPC Data Access
(MP 277, MP 377, WinCC flexible Runtime only)
OPC Data Access is an open standard for exchanging both local
and remote variables between various applications via Industrial
Ethernet. The original version of OPC is based on Microsoft
COM/DCOM and, therefore, requires a Microsoft Windowsbased PC operating system (not Windows CE) on both clients
and servers. As OPC XML, communication is based on the
Internet standard SOAP/XML and is, therefore, suitable for
embedded systems with Windows CE.
Options that are required: WinCC flexible/OPC server
Communication based on HTTP message frames enables
variables to be exchanged between SIMATIC HMI systems.
Options that are required: WinCC flexible/[email protected] Access
Note
Interface options for HMI devices: See the individual device
descriptions.
Communication standard
SIMATIC HMI
Version
TP 177B DP/PN
TP 277
Mobile Panel 277
OP 177B DP/PN
Mobile Panel 177 PN
OP 277
Mobile Panel 277
IWLAN
6)
WinCC flexible
Runtime
Connection via
MP 277
MP 177
MP 377
OPC Data Access V2.05a + OPC Data Access XML V1.00
OPC client
(COM/DCOM)
–
–
–
•
Industrial Ethernet
(see Catalog IK PI)
OPC server
(COM/DCOM)
–
–
–
•1)
Industrial Ethernet
(see Catalog IK PI)
OPC XML client
(SOAP/XML)
–
–
–
•2)
Industrial Ethernet
(see Catalog IK PI)
OPC XML server
(SOAP/XML)
–
–
•3)
–
Industrial Ethernet
(see Catalog IK PI)
HTTP communication for variable exchange between SIMATIC HMI systems
HTTP client
•4)
•4)
•4)
•5)
Industrial Ethernet
(see Catalog IK PI)
HTTP server
•4)
•4)
•4)
•5)
Industrial Ethernet
(see Catalog IK PI)
• System interface possible
– System interface not possible
1)
Option WinCC flexible/OPC Server for WinCC flexible Runtime required
4)
Option WinCC flexible/[email protected] for SIMATIC Panel required
2)
Only with DCOM/XML gateway included in the scope of delivery of
WinCC flexible for access to MP 277, MP 377 and MP 370 OPC XML
servers
Option WinCC flexible/OPC Server for SIMATIC Multi Panel required
5)
Option WinCC flexible/[email protected] for WinCC flexible Runtime required
Depending on the terminal box used
3)
6)
Siemens ST 80 / ST PC · 2013
2/83
2
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S7
■ Overview
2
The following types of interface are supported in respect of the
link between SIMATIC HMI Panels and SIMATIC WinCC flexible
Runtime with SIMATIC S7:
• PPI interface:
Interface between SIMATIC HMI Panels and SIMATIC S7-200
via PPI. Communication runs on the PPI protocol, a standard
FB as with SIMATIC S5 is not required.
• MPI interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PPI interface with S7-200 or MPI interface with
S7-300/-400 or alternatively via the MPI interface of a separate
interface module and the backplane bus to the SIMATIC S7CPU. Communication runs on the MPI protocol (PG/OP
communication), a standard FB as with SIMATIC S5 is not
required.
• PROFIBUS interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PROFIBUS interface on the CPU or alternatively
via the PROFIBUS interface on a separate interface module
and the backplane bus to the SIMATIC S7-CPU. Communication runs on the MPI protocol (PG/OP communication), a
standard FB as with SIMATIC S5 is not required.
• PROFINET interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PROFINET interface on the CPU or alternatively
via the Industrial Ethernet interface on a separate interface
module and the backplane bus to the SIMATIC S7-CPU.
Communication runs on the MPI protocol (PG/OP communication), a standard FB as with SIMATIC S5 is not required.
The maximum possible number of S7 connections of a CPU is
determined by its power (see Catalog ST 70); from the point of
view of SIMATIC HMI Panels the following restrictions apply:
• OP 73micro, TP 177micro: 1 connection
• OP 73: max. 2 connections
• OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B,
Mobile Panel 177: max. 4 connections
• TP 277, OP 277; Mobile Panel 277, MP 177, MP 277, MP 377:
max. 6 connections
• PC with WinCC flexible Runtime: max. 8 connections
2/84
Siemens ST 80 / ST PC · 2013
PPI interface
From the point of view of the concept, the PPI interface is a pointto-point connection between a SIMATIC HMI Panel (PPI master)
or alternatively a PG (PPI master), and an S7-200 (PPI slave).
MPI interface/PROFIBUS interface/
Industrial Ethernet interface
The multipoint-enabled communication interfaces of
SIMATIC HMI Panels and SIMATIC S7 are used.
Options are:
• Interface between one or a number of SIMATIC HMI Panels
(MPI master) and one or a number of S7-300/400s or WinAC
(MPI master)
(possible network topology: "MPI/PROFIBUS/Industrial
Ethernet")
• Interface between one or a number of SIMATIC HMI Panels
(MPI master) and one or a number of S7-200s (MPI slave) 1)
(possible network topology: "PPI/MPI/PROFIBUS")
Unlike PPI connections, MPI connections are static connections
that are set up during booting and then monitored.
The original format of a master/master link has in the meantime
been joined by a master/slave link, which has enabled
integration of the S7-200 (except CPU 212). 1)
In principle this type of information exchange between
SIMATIC HMI Panels and SIMATIC S7 is independent of the
network used, PPI, MPI, PROFIBUS or Industrial Ethernet:
SIMATIC HMI Panels are S7 clients and SIMATIC S7 CPUs are
S7 servers.
1)
Constraints with regard to baud rate for S7-200; see Catalog ST 70.
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S7
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
TD 100C
OP 73micro
TD 200
TP 177micro
OP 73
OP 77A
Connection via
TP 177A
TD 200C
TD 400C
2
SIMATIC S7 (PPI/MPI)
via PPI on S7-200 (PPI)
• 1)
–
–
–
MPI cable 5)
via MPI or PROFIBUS
(PG/OP communication)
with S7-200
–
• 2)
• 3)
• 4)
MPI cable 5)
via MPI or PROFIBUS
(PG/OP communication)
with S7-300, -400
–
–
• 3)
• 4)
MPI cable 5)
via PPI network (PPI)
with max. 1 x S7-200
• 1)
–
–
–
PPI network 6)
(see Catalog ST 70 and IK PI)
via PPI network
(PG/OP communication)
with max. 4 x S7-200
• 1)
• 2)
• 3)
• 4)
PPI network 6)
(see Catalog ST 70 and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-200
–
• 2)
• 3)
• 4)
MPI or PROFIBUS network 6)
(see Catalogs ST 70 and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-300, -400, WinAC
–
–
• 3)
• 4)
MPI or PROFIBUS network 6)
(see Catalogs ST 70 and IK PI)
via Industrial Ethernet (TCP/IP)
(PG/OP communication)
with max. 4 x S7-200, -300, -400,
WinAC
–
–
–
–
Industrial Ethernet
(see Catalog IK PI)
• System interface possible
– System interface not possible
1)
2)
TD series can only be interfaced with max. 1 x S7-200 via PPI (PPI/MPI);
network operation (parallel PG, etc.) possible; max. data transfer rate
187.5 kbit/s; cable included in scope of supply
OP 73micro, TP 177 micro can only be interfaced with max. 1 x S7-200
(MPI); network operation (parallel PG, etc.) possible; max. data transfer
rate 187.5 kbit/s
3)
OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI); network
operation (parallel PG, etc.) possible; max. data transfer rate 1.5 Mbit/s
4)
5)
Max. transmission rate 1.5 Mbit/s
MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG
scope of delivery
6)
Bus connector 6GK1 500-0EA02
Siemens ST 80 / ST PC · 2013
2/85
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S7
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
Basic Panels
2
OP 77B
TP 277
TP 177B DP
OP 277
OP 177B DP
Mobile Panel 277
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 277
IWLAN
Mobile Panel 177 DP
MP 177
Mobile Panel 177 PN
MP 277
WinCC flexible
Runtime
Connection via
MP 377
via PPI on S7-200 (PPI)
–
2)
• 1) 2)
• 1) 2)
• 1) 3)
MPI cable 11)
2)5)
2) 5)
3) 5)
MPI cable 11)
via MPI or PROFIBUS
(PG/OP communication)
on S7-200
•
via MPI or PROFIBUS
(PG/OP communication)
with S7-300, -400
• 2)
• 2)
• 2)
• 3)
MPI cable 11)
via PPI network (PPI)
with max. 1 x S7-200
–
• 1) 2)
• 1) 2)
• 1) 3)
PPI network 12)
(see Catalog ST 70
and IK PI)
via PPI network
(PG/OP communication)
with max. 4 x S7-200
• 2)
• 6)
–
–
PPI network 12)
(see Catalog ST 70
and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-200
• 2)
• 2) 5)
• 2) 5)
• 3) 5)
MPI or PROFIBUS
network 12)
(see Catalogs ST 70
and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-300, -400, WinAC
• 2)
• 2)
• 2)
• 3)
MPI or PROFIBUS
network 12)
(see Catalogs ST 70
and IK PI)
via Industrial Ethernet (TCP/IP)
(PG/OP communication)
with max. 4 x S7-200, -300, -400,
WinAC
– 7)
• 7) 8)
• 8) 9)
• 10)
Industrial Ethernet
(see Catalog IK PI)
•
•
•
• System interface possible
– System interface not possible
1)
2)
Can only be interfaced with max. 1 x S7-200 via PPI (PPI);
network operation (parallel PG, etc.) possible
Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special
connecting cable and junction box (see Mobile Panel);
Please refer to the manual for cable assignment
7)
8)
9)
Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel);
Please refer to the manual for cable assignment
Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC
3)
Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2
with a standard PC.
10) Connection
4)
Max. transmission rate 1.5 Mbit/s
11)
5)
Only on passive S7-200; OP 77B (MPI) also on active S7-200
6)
Only OP 77B (MPI)
2/86
Siemens ST 80 / ST PC · 2013
MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG
scope of delivery (for download and test purposes only)
12) Bus
connector 6GK1 500-0EA02
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S5
■ Overview
A variety of interfaces differing in respect of type and
performance are available for linking SIMATIC HMI Panels to
SIMATIC S5 (not S5-150U). However, a feature common to all is
that from the point of view of the connected SIMATIC HMI Panel,
the connection is always a logical point-to-point one, i.e. there is
always a fixed assignment between a SIMATIC HMI Panel and a
PLC.
AS511 interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177,
Mobile Panel 277)
S5-90U to -135U, -155U
(except CPU 922 < Version 9,
except CPU 928 [6ES5 928-3UA11],
except CPU 946/947 [6ES5 94•-3UA11],
except CPU 946/947 [6ES5 94•-3UA21],
except CPU 946/947 [6ES5 94•-3UA22] < Version 5)
The AS511 interface is implemented via the PG interface of
SIMATIC S5 and uses the associated CPU resources, that is, the
performance capability of the SIMATIC HMI Panel is determined
by the performance capability of the SIMATIC CPU used.
PROFIBUS DP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
S5-115U, -135U, -155U via IM 308C or
CP 5431 FMS/ DP (except CPU 922 < Version 9,
except CPU 928 [6ES5 928-3UA11],
except CPU 946/947 [6ES5 94•-3UA11],
except CPU 946/947 [6ES5 94•-3UA21],
except CPU 946/947 [6ES5 94•-3UA22] < Version 5)
2
The PROFIBUS DP interface supports the connection of:
• Up to 2 SIMATIC HMI Panels as SLAVES via a PROFIBUS
network to a SIMATIC S5-95U with integrated PROFIBUS DP/
master interface [6ES5 095-8ME01]
• Up to 30 SIMATIC HMI Panels as SLAVES via a PROFIBUS
network to a SIMATIC S5 with separate PROFIBUS DP/master
interface IM 308C, or CP 5431 FMS/DP
Communication between SIMATIC HMI Panels (DP slaves)
and SIMATIC S5 (DP master) runs via PROFIBUS DP message
frames in accordance with EN 50170 with higher-level
"HMI profile". A function block which must be called for each
connected SIMATIC HMI Panel is required in the PLC
(FB is included in scope of delivery).
Siemens ST 80 / ST PC · 2013
2/87
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S5
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
OP 77A
OP 77B
TP 277
(physics)
TP 177A
TP 177B DP
OP 277
Basic Panel
OP 177B DP
Mobile Panel 277
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 277 IWLAN
MP 177
Mobile Panel 177 DP
MP 277
Mobile Panel 177 PN
MP 377
• 2)
–
2
WinCC flexible
Runtime
Connection via
•
6ES5 734-1BD201)
(3.2 m)
SIMATIC S5 (AS511)
S5-90U to 155U
except CPU 922 < version 9,
–
except CPU 928
(6ES5 928-3UA11)
6XV1 440-2A…
(see HMI accessories/
connecting cables)
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
(TTY)
S5-90U to 155U
–
• 3) 5)
• 3)
–
except CPU 922 < version 9,
6AV6 671-8XJ000AX0
except CPU 928
(6ES5 928-3UA11)
(RS422-TTY adapter)
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
(TTY)
(see HMI accessories/
connecting cables)
6XV1 440-2A…
SIMATIC S5 (PROFIBUS DP + HMI)
via PROFIBUS DP with
1 x S5-95U/L2-DP/master
(6ES5 095-8ME02)
–
via PROFIBUS DP with IM 308C
on S5-115U, -135U, -155U
–
•3)
•3)
•4)
PROFIBUS4)
(see Catalog IK PI)
•3)
•3)
•4)
PROFIBUS4)
(see Catalog IK PI)
except CPU 922 < version 9,
except CPU 928
(6ES5 928-3UA11),
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
via PROFIBUS DP with
CP 5431 FMS/DP on
–
•3)
S5-115U, -135U, -155U
except CPU 922 < version 9,
except CPU 928
(6ES5 928-3UA11),
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
• System interface possible
– System interface not possible
1)
PC cable with integrated level converter RS 232/TTY
2)
OP 77B only
WinCC flexible 2008 Service Pack 2 and higher
3)
4)
Connection via integrated MPI/PROFIBUS interface: use the CP 5611 A2
for a standard PC.
5)
not for OP 77B; in this case the RS 232 interface is to be used.
2/88
Siemens ST 80 / ST PC · 2013
•3)
•4)
PROFIBUS4)
(see Catalog IK PI)
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC 505
■ Overview
A variety of interfaces differing in respect of type and performance are available for linking SIMATIC HMI Panels to
SIMATIC 505.
PROFIBUS DP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
However, a feature common to all is that from the point of view of
the connected SIMATIC HMI Panel, the connection is always a
logical point-to-point one, that is, there is always a fixed
assignment between an HMI Panel and a PLC.
SIMATIC 505 PLC or SIMATIC 545, SIMATIC 555 with CP 5434
With the PROFIBUS DP interface, up to 30 SIMATIC HMI Panels
can be connected as SLAVES to one SIMATIC 545, 555 via a
PROFIBUS network, with plug-in PROFIBUS DP/master interface
type CP 5434.
NITP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Communication between SIMATIC HMI Panels (DP slaves) and
SIMATIC 505 (DP master) runs via PROFIBUS DP message
frames in accordance with EN 50170 with higher-level "HMI
profile". An application ladder which must be called for each
connected SIMATIC HMI Panel is required in the PLC (example
of application ladder included in ProTool scope of delivery).
The NITP interface runs via the PG interface of the SIMATIC 505
and uses the associated CPU resources, that is, the performance capability of the SIMATIC HMI Panel is determined by the
performance capability of the SIMATIC CPU used.
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
OP 77B
TP 277
TP 177A
TP 177B DP
OP 277
Basic Panel
OP 177B DP
Mobile Panel 277
TP 177B DP/PN
Mobile Panel 277 IWLAN
OP 177B DP/PN
Mobile Panel 177 DP
MP 177
MP 277
Mobile Panel 177 PN
MP 377
–
• 1) 2)
• 1) 2)
–
1) 2)
1) 2)
WinCC flexible
Runtime
Connection via
•
PPX: 2601 094-8001 3)
SIMATIC 505 (NITP)
PLC 525, 535, 565T
(RS 232)
PLC 545, 555
(RS 232)
See online help 6)
•
•
PPX: 2601 094-8001 3)
•
6XV1 440-2K…
(see HMI accessories/
connecting cables)
PLC 535, 545/CPU 1101, 565T
(RS 422)
–
• 1)
• 1)
• 4)
See online help 6)
PLC 545/CPU 1102, 555
(RS 422)
–
• 1)
• 1)
• 4)
See online help 6)
• 1)
• 1)
• 5)
PROFIBUS 7)
SIMATIC 505 (PROFIBUS DP + HMI)
via PROFIBUS DP to
1 x PLC 545, 555 with CP 5434
–
(see Catalog IK PI)
• System interface possible
– System interface not possible
1)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and
junction box (see Mobile Panel); see manual for cable assignment.
2)
The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch
Panels, Operator Panels, and Multi Panels
3)
A standard adapter (9-/25-pin male) is required on the PLC
4)
A commercially available level converter (RS 232/RS 422) is required on
the PC
5)
Connection via integrated MPI/PROFIBUS interface, use the CP 5611 A2
with a standard PC
6)
Detailed information (cable assignment) can be found in the online help for
WinCC flexible and in the Communication User Manual for Windows-based
systems
7)
Bus connector 6GK1 500-0EA02
Siemens ST 80 / ST PC · 2013
2/89
2
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
■ Overview
Allen Bradley
Three communication protocols are available for the interface
between SIMATIC TP/OP/MP and Allen Bradley:
2
DF1 interface
(not on OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs on the basis of the DF1 protocol; the following have
been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and the PG
interface on an Allen Bradley PLC5 or the DF1 interface on an
Allen Bradley SLC500 (point-to-point link)
• The integration of SIMATIC TP/OP/MP via Allen Bradley KF2
gateway in an Allen Bradley DH+ network. Communication is
possible between SIMATIC TP/OP/MP and up to 4 SLC 500
PLCs or PLC5s (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with TP
170A)
• The integration of SIMATIC TP/OP/MP via Allen Bradley KF3
gateway in an Allen Bradley DH485 network. Communication
is possible between SIMATIC TP/OP/MP and up to 4 PLCs
type SLC 500 or MicroLogix (multipoint link from the point of
view of the SIMATIC TP/OP/MP; only one connection possible
with TP 170A)
DH485 interface
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs on the basis of the DH485 protocol; the following
have been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and an Allen
Bradley SLC500 or MicroLogix (point-to-point link)
• The integration of SIMATIC TP/OP/MP via Allen Bradley AIC
adapter in an Allen Bradley DH485 network. Communication
is possible between SIMATIC TP/OP/MP and up to 4 PLCs
type SLC 500 or MicroLogix (multipoint link from the point of
view of the SIMATIC TP/OP/MP; only one connection possible
with TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with
WinCC flexible Runtime) in an Allen Bradley DH485 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 PLCs type SLC 500 or MicroLogix (multipoint link from
the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Ethernet IP protocol
(not on OP 73, OP 77A, TP 177A, Basic Panel, OP 77B,
TP 177B DP, OP 177B DP, Mobile Panel 177 DP,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and
Allen Bradley runs based on the Ethernet IP protocol;
SIMATIC TP/OP/MP integration is tested and released in an
Ethernet IP network. Communication is possible between
SIMATIC TP/OP/MP and up to 4 ControlLogix or
CompactLogix PLCs (multipoint link from the point of view
of the SIMATIC TP/OP/MP)
2/90
Siemens ST 80 / ST PC · 2013
GE-Fanuc
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and GE-Fanuc
runs on the basis of the SNP protocol; the following have been
tested and released:
• Direct connection between a SIMATIC TP/OP/MP and
a GEF 90-Micro, 90-30 or 90-70 (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network
via adapter. Communication is possible between
SIMATIC TP/OP/MP and up to 4 GEF 90-Micro, 90-30 or
90-70 PLCs (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with
TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 GEF 90-Micro, 90-30 or 90-70 PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
LG GLOFA GM
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and
LG GLOFA GM runs on the basis of the dedicated protocol;
the following have been tested and released:
• Connection between a SIMATIC TP/OP/MP and an
LG GLOFA GM with Cnet module (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network via
LG Cnet module. Communication is possible between
SIMATIC TP/OP/MP (not PC with ProTool/Pro Runtime) and up
to 4 LG GLOFA GM PLCs on the network (multipoint link from
the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Mitsubishi
(not with OP 73, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Mitsubishi:
FX protocol
This communication between SIMATIC TP/OP/MP and
Mitsubishi runs on the basis of the FX protocol; the direct
connection between a SIMATIC TP/OP/MP and the PG interface
of a Mitsubishi FX/FX0 (logical point-to-point link) has been
tested and released.
MP4 protocol
This communication between SIMATIC TP/OP/MP and
Mitsubishi runs on the basis of the MP4 protocol;
the following have been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and a
Mitsubishi Series FX, Series A or Series Q (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network via
Mitsubishi converter FX-48SC-IF. Communication is possible
between SIMATIC TP/OP/MP and up to 4 Series FX, Series A
or Series Q PLCs (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with
TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 Series FX, Series A or Series Q PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
■ Overview (continued)
Modicon
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Modicon:
Omron
(not with OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and Modicon runs
on the basis of the Modbus protocol; the following have been
tested and released:
• Direct connection between a SIMATIC TP/OP/MP and the
Modbus interface on a Modicon 984, TSX Quantum or
TSX Compact (point-to-point link)
• The integration of a SIMATIC TP/OP/MP via Modicon
Modbus PLUS bridge BM85-000 or the bridge function of a
MODICON 984-145 or TSX Quantum into a Modbus PLUS
network and communication between SIMATIC TP/OP/MP
(Modbus/master) and up to 4 Modicon 984 or TSX Quantum
PLCs (Modbus/slave) on the network (multipoint link from the
point of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A).
Communication between SIMATIC TP/OP/MP and Omron runs
on the basis of the Link/MultiLink protocol; the following have
been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and an
Omron Sysmac C, Sysmac D or Sysmac CV (point-to-point
link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network
via Omron converter NT-AL001. Communication is possible
between SIMATIC TP/OP/MP and up to 4 Sysmac C,
Sysmac D or Sysmac CV PLCs (multipoint link from the point
of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 Sysmac C, Sysmac D or Sysmac CV PLCs (multipoint
link from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Modbus TCP/IP protocol
(not for OP 73, OP 77A, TP 177A, Basic Panel DP, OP77B,
TP 177B DP, OP 177B DP, Mobile Panel 177 DP,
Mobile Panel 277 IWLAN)
Telemecanique
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN,
WinCC flexible Runtime)
This communication between SIMATIC TP/OP/MP and Modicon
runs on the basis of the Modbus TCP/IP protocol; the following
have been tested and released:
• Integration of SIMATIC TP/OP/MP into a Modbus TCP/IP
network. Communication is possible between
SIMATIC TP/OP/MP and up to 4 Momentum, TSX Micro
( TSX 37 ), TSX Premium ( TSX 57 ), TSX Unity Premium,
TSX Quantum or TSX Unity Quantum PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP)
• The communication between SIMATIC TP/OP/MP via
TCP/IP Modbus Plus Bridge 174 CEV 200 40 / Modbus PLUS
network to Modicon 984 (except 984A, 984B, 984X ),
TSX Compact, TSX Quantum or TSX Unity Quantum (multipoint link from the point of view of the SIMATIC TP/OP/MP)
Data exchange between SIMATIC TP/OP/MP and
Telemecanique runs on the basis of the UNI-TELWAY protocol;
the following have been tested and released:
• Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via
Telemecanique outlet TSX SCA62 and a Telemecanique
TSX 17 or TSX 47/67/87/107 (UNI-T/master)
(logical point-to-point link)
• Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via
Telemecanique outlets TSX SCA62 + ACC01 and a Telemecanique TSX 37 or TSX 57 (UNI-T/master) (logical point-to-point
link)
• The integration of a SIMATIC TP/OP/MP via Telemecanique
outlet TSX SCA62 in a UNI-TELWAY network and communication between SIMATIC TP/OP/MP (UNI-T/slave) and up to
4 TSX 17, TSX 37, TSX 57 or TSX 47/67/87/107 PLCs (UNI-T/
master or slave) on the network (multipoint link from the point
of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A).
Modbus protocol
(not for OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Siemens ST 80 / ST PC · 2013
2/91
2
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
Basic Panel
TP 177A
OP 77B
TP 277
TP 177B DP
OP 277
OP 177B DP
Mobile Panel
277 / 277 IWLAN
MP 177
TP 177B DP/PN
OP 177B DP/PN
2
Mobile Panel
177 DP / 177 PN
MP 277
WinCC flexible
Runtime
Connection via
1747 CP3 7)
MP 377
Allen Bradley (DF1)
SLC 500/03,04,05 or MicroLogix
(RS 232)
• 1) 2)
• 1) 2)
• 1) 2)
• 1) 2)
•
PLC 5/11,20,30,40,60,80 (RS 232)
• 1) 2)
• 1) 2)
• 1) 2)
• 1) 2)
•
PLC 5/11,20,30,40,60,80 (RS 422)
•
1)
•
1)
•
1)
•
1)
–
See FAQ 9)
via KF2 gateway and
DH+ network with up to
4 x SLC 50/04 or
PLC 5/11,20,30,40,60,80 (RS 232)
•
1) 2)
•
1) 2)
•
1) 2)
•
1) 2)
•
1784 CP10 7) 8)
via KF2 gateway and
DH+ network with up to
4 x SLC 50/04 or
PLC 5/11,20,30,40,60,80 (RS 422)
• 1)
• 1)
• 1)
• 1)
–
See FAQ 9)
via KF3 gateway and
DH485 network with up to
4 x SLC 500/00,01,02,03,04,05 or
MicroLogix (RS 232)
• 1) 2)
• 1) 2)
• 1) 2)
• 1) 2)
•
1784 CP10 7)8)
See FAQ 9)
1784 CP10 7)
See FAQ 9)
See FAQ 9)
See FAQ 9)
Allen Bradley (DH485)
SLC 500/03,04,05 or
MicroLogix (RS 232)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 9)
via AIC adapter and
DH485 network with up to
4 x SLC 500 or MicroLogix
(RS 232)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 9)
via DH485 network with up to
4 x SLC 500/00,01,02,03,04,05 or
MicroLogix (RS 485)
–
–
• 1)
• 1)
–
See FAQ 9)
–
–
• 3) 4)
• 4)
•
See FAQ 9)
Allen Bradley (Ethernet IP)
via Ethernet IPnetwork
with up to 4 x ControlLogix
(1756-L61, 1756-L62, 1756-L63,
1756-L64, 1756-L65, each with
Ethernet module 1756-ENBT)
GuardLogix
(1756-L61S, 1756-L62S,
1756-L61S, each with Ethernet
module 1756-ENBT) or
CompactLogix
(1769-L32E, 1769-L35E, each with
Ethernet interface onboard
• System interface possible
– System interface not possible
1)
Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.
2)
The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Basic Panel, Touch Panel, Operator Panel, and Multi Panel
3)
Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN
4)
Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.
Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
5)
6)
Connection via integrated Industrial Ethernet interface; use the
CP 1612 with a standard PC
7)
Allen Bradley PC cable
Cable for connection to KF2/KF3 gateway; a gander changer
(25-pin socket/25-pin socket) is required on the gateway side
8)
2/92
Siemens ST 80 / ST PC · 2013
9)
Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071
in the online help for WinCC flexible and in the Communication User
Manual for Windows-based systems
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
Basic Panel
TP 177A
OP 77B
TP 277
TP 177B DP
OP 277
WinCC flexible
Runtime
OP 177B DP
Mobile Panel 277
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 277
IWLAN
Mobile Panel 177 DP
MP 177
Mobile Panel 177 PN
MP 277
Connection via
2
MP 377
GE-Fanuc (SNP)
GEF 90-Micro, 90-30, 90-70
(RS 232)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 4)
via adapter with up to 4 x GEF
90-Micro, 90-30, 90-70 (RS 232)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 4)
via adapter with up to 4 x GEF
90-Micro, 90-30, 90-70 (RS 422)
–
–
• 1)
• 1)
–
See FAQ 4)
GLOFA-GM with Cnet module
(RS 232)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 4)
With up to 4 x GLOFA-GM with
Cnet module (RS 422)
–
–
• 1)
• 1)
–
See FAQ 4)
–
–
–
–
•
SC-09 6)
–
See FAQ 4)
LG GLOFA (Dedicated)
Mitsubishi FX
FX0 (RS 422)
FX0n, FX1n, FX2n (RS 422)
–
–
•
–
–
–
1)
•
1)
•
SC-09 6)
1)
–
–
See FAQ 4)
SC-09 6)
–
1)
–
• 1) 6)
–
• 1) 6)
•
–
• Series FX
with communications module
• Series A (AnN, AnA, AnU, AnS)
with interface module
• Series Q (QnA, QnAS) with
interface module (RS 232)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 4)
via FX-48SC-IF converter
with up to 4 PLCs
• Series FX with communications
module
• Series A (AnN, AnA, AnU, AnS)
with interface module
• Series Q (QnA, QnAS) with
interface module (RS 232)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 4)
with up to 4 PLCs
• Series FX
with communications module
• Series A (AnN, AnA, AnU, AnS)
with interface module
• Series Q (QnA, QnAS) with
interface module (RS 422)
–
–
• 1)
• 1)
–
See FAQ 4)
• FX1N-14MR-DS
• FX1S-10MR-DS
• FX2N-16MR-DS (RS 422)
•
–
Mitsubishi (MP4)
• System interface possible
– System interface not possible
1)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and junction
box (see Mobile Panel); see manual for cable assignment.
2)
The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch
Panels, Operator Panels, and Multi Panels
3)
With connection using a Mitsubishi PC cable, an 15-pin/9-pin adapter
6XV1 440-2UE32 is required
4)
Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/de/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems
5)
Mitsubishi PC cable with integrated level converter RS 232/RS 422
6)
WinCC flexible 2008 Service Pack 2 and higher
Siemens ST 80 / ST PC · 2013
2/93
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
Basic Panel
TP 177A
2
OP 77B
TP 277
TP 177B DP
OP 277
OP 177B DP
Mobile Panel 277
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 277
IWLAN
Mobile Panel 177 DP
MP 177
Mobile Panel 177 PN
MP 277
WinCC flexible
Runtime
Connection via
MP 377
Modicon (Modbus)
984-120, 130, 131, 141, 145,
380, 381, 185, 480, 485, 680,
685, 780, 785, or
TSX-Quantum-CPU 113, 213,
424, 434, 534 (RS 232)
• 1) 2)
• 1) 2)
• 1) 2)
• 1) 2)
•
See FAQ 7)
via bridge BM85-000 or
PLC with bridge function. /
Modbus PLUS network
with up to 4 x 984-120, ... or
TSX Quantum - CPU 113, or
TSX Contact
(RS 232)
• 1) 2)
• 1) 2)
• 1) 2)
• 1) 2)
•
See FAQ 7)
TSX Compact (RS 232)
• 1) 2)
• 1) 2)
• 1) 2)
• 1) 2)
•
See FAQ 7)
via Modbus TCP/IP network
with up to 4 x
TSX Unity Quantum or
TSX Unity Premium or
TSX Quantum or
TSX Quantum with TCP/IP
module 140 NOE 771 01 or
TSX Unity Premium or
TSX Premium with
TCP/IP module TSX ETY 110
or TSX Micro with
TCP/IP module TSX ETY 410
or Momentum with
CPU adapter 171 CCC 980 30
–
–
• 3) 4)
• 4) 5)
•
via TCP/IP ModbusPlus bridge
174 CEV 200 40 / Modbus PLUS
network with up to 4 x
TSX Unity Quantum or
TSX Quantum or
TSX Compact or 984-120, ...
(except 984A, 984B, 984X )
–
–
• 3) 4)
• 4) 5)
•
via Modbus TCP/IP network
with up to 4 x
TSX Unity Quantum or
TSX Unity Premium or
TSX Quantum or
TSX Quantum with TCP/IP
module 140NOE 771 01 or
TSX Unity Premium or
TSX Premium with TCP/IP
module TSX ETY 110 or
TSX Micro with TCP/IP module
TSX ETY 410 or
Momentum with CPU adapter
171 CCC 980 30
• 3) 8)
• 3) 8)
–
–
–
via TCP/IP ModbusPlus Bridge
174 CEV 200 40 / Modbus PLUS
network with up to 4 x
TSX Unity Quantum or
TSX Quantum or
TSX Compact
• 3) 8)
• 3) 8)
–
–
–
Modicon (Modbus TCP/IP)
• System interface possible
– System interface not possible
1)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and
junction box (see Mobile Panel); see manual for cable assignment.
5)
Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
6)
2)
The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Touch Panels, Operator Panels, and Multi Panels
7)
3)
Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN
4)
Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.
Connection via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC
Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems
2/94
Siemens ST 80 / ST PC · 2013
8)
WinCC flexible 2008 Service Pack 2 and higher
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
■ Overview (continued)
Controller
SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
Basic Panel
TP 177A
OP 77B
TP 277
TP 177B DP
OP 277
WinCC flexible
Runtime
OP 177B DP
Mobile Panel 277
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 277
IWLAN
Mobile Panel 177 DP
MP 177
Mobile Panel 177 PN
MP 277
Connection via
2
MP 377
Omron (Link/MultiLink)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 3)
–
–
• 1) 2)
• 1) 2)
•
See FAQ 3)
–
–
• 1)
• 1)
–
See FAQ 3)
• 1) 4)
• 1) 4)
–
–
–
–
via TSX SCA62 outlet with
TSX 17 or TSX 47/67/87/107 (RS 485)
–
• 1)
• 1)
–
See FAQ 3)
via TSX SCA62 + ACC01 outlets
with TSX 37/57 (RS 485)
–
–
• 1)
• 1)
–
See FAQ 3)
via TSX SCA62 outlet and
UNI-TELWAY network with
4 x TSX 17 or TSX 37/57 (+ACC 01)
or TSX 47/67/87/107 (RS 485)
–
–
• 1)
• 1)
–
See FAQ 3)
• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC Alpha
• SYSMAC CV (RS 232)
via NT-AL001 converter
with up to 4 PLCs
• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC Alpha
• SYSMAC CV (RS 232)
with up to 4 PLCs
• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC Alpha
• SYSMAC CV (RS 422)
• CP1L-L14DT1-D
• C1H-Y20DT-D
• CJ1M CPU11
Telemecanique (UNI-TELWAY)
• System interface possible
– System interface not possible
1)
2)
Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and junction
box (see Mobile Panel); see manual for cable assignment.
The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Touch Panels, Operator Panels, and Multi Panels
3)
Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems
4)
WinCC flexible 2008 Service Pack 2 and higher
Siemens ST 80 / ST PC · 2013
2/95
© Siemens AG 2013
Operator panels
SIMATIC HMI accessories
General HMI accessories
■ Overview
The specially coordinated range of accessories supplements
the SIMATIC HMI core products perfectly. Industrial Hub 4 can
be used, for example, to make a USB port available to the user
exactly where it is required. Touch pens can be used to operate
extremely small buttons, and they also ensure that the display
stays clean for longer.
2
SIMATIC HMI accessories can also be used in non-Siemens
devices; see the technical specifications for more detailed information.
General SIMATIC HMI accessories for all currently available
Panels are listed in this chapter; the full range of SIMATIC HMI
accessories is available in the Mall and in our other online
media.
Industrial USB Hub 4
Touchscreen stylus and touch pen
2/96
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI accessories
Industrial USB Hub 4
■ Overview
• The Industrial USB Hub 4 is used as a USB port extender
(4 in 1) for the connection of peripheral devices to USB 2.0
interfaces of Comfort Panels, Multi Panels, IPCs, and standard
PCs.
• The Industrial USB Hub 4 (IP65 degree of protection on the
front, service kit may be required) can also be mounted
directly in a control cabinet.
• With the USB Hub 4, the USB port can be moved forwards to
the control cabinet door, making it accessible without opening
the cabinet door
• The USB Hub 4 can also be mounted on a standard mounting
rail in the control cabinet, in which case it serves as a simple
interface multiplier
■ Technical specifications
6AV6671-3AH00-0AX0
6AV6671-3AH00-0AX0
Industrial USB Hub 4
Installation type/mounting
Mounting rail installation possible
Mounting in landscape format
possible
Yes; Standard - DIN rail
Yes
Supply voltage
Type of supply voltage
24 V DC
Rated voltage/DC
24 V
permissible range, lower limit (DC)
20.4 V
permissible range, upper limit (DC)
28.8 V
Interfaces
Number of USB interfaces
4; Type USB 2.0, 500 mA each;
e.g. connection of mouse,
keyboard, printer, USB stick,
USB IPC flash drive
Industrial USB Hub 4
Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
0 °C to +50 °C
0 °C
50 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
Relative humidity
• max. relative humidity
90 %
Mechanics/material
Type of housing (front)
• Plastic
Yes
212 mm
Degree and class of protection
Type of protection
20
Dimensions
Width of the housing front
IP (at the front)
65
Height of housing front
156 mm
Depth/installation dimension
50 mm
Weight
Weight without packaging
460 g
Standards, approvals, certificates
CE
Yes
Scope of supply
Delivery unit in items
1; Content: 1 X USB Hub 4,
10 x plastic mounting clip,
1 x female 2-pin connector
other
Note:
■ Ordering data
Order No.
Industrial USB Hub 4
4 x USB 2.0, IP65, for control cabinet door or standard rail, for use
with MP 177/MP 277/MP 377, Panel
PCs, HMI IPCs and standard PCs
6AV6671-3AH00-0AX0
Service set for Industrial USB
Hub 4 (incl. IP65 expansion)
See HMI accessories service sets,
from page 2/118
for access to the USB interface of
a built-in device without having to
open the control cabinet, mounting
on standard rail possible, suitable
for standard USB interfaces
■ More information
Note for SIMATIC Panel PCs
The Industrial USB Hub 4 is approved for the Windows CE/2000/
XP/Windows 7 operating systems. The appropriate drivers are
supplied with the operating system software.
Siemens ST 80 / ST PC · 2013
2/97
2
© Siemens AG 2013
Operator panels
SIMATIC HMI accessories
Touch pen and touch stylus
■ Overview
If you are working with gloves, touch pens are often extremely
useful when operating touch displays. They protect the display
from dirt and scratching during operation and use. They are also
useful for operating small buttons or input fields accurately.
2
Optional package: Touchscreen stylus and touch pen
■ Technical specifications
6AV7672-1JB00-0AA0
Touch pen, thick, resistive technology
6AV6645-7AB14-0AS0
Touch pen, thin, resistive technology
Installation type/mounting
Wall mounting/direct mounting possible
Yes; Terminal holder can be attached
Yes; using 40 cm retaining cord
Standards, approvals, certificates
CE
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
90 %
90 %
Mechanics/material
Screw type
• Torx
Yes
Plastic
Yes
Yes
Dimensions
Height
155 mm; Length
125 mm; Length
Thickness
20 mm; Diameter
8 mm; Diameter
Scope of supply
Delivery unit in items
1; Optional for extension units of the PRO devices
5; Incl. retaining cord for Mobile Panel 277 10"
for resistive touch screens, optimized for operating
while wearing gloves
for resistive touch screens
other
Note:
■ Ordering data
Touch stylus
Order No.
6AV7672-1JB00-0AA0
Touch pen
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
6AV6645-7AB14-0AS0
Specially designed for
Mobile Panel 277 10",
but also other touch displays,
including attachment cord
• 5 units
2/98
Note:
This catalog only includes accessories for current products.
for Panels, Panel PC, Touch Monitor
and other touch applications,
including screw-on wall holder
• 1 unit
Siemens ST 80 / ST PC · 2013
or on our SIMATIC Support pages:
http://support.automation.siemens.com
© Siemens AG 2013
Operator panels
Mobile Panel accessories
SIMATIC Mobile Panel accessories
■ Overview
General Mobile Panel accessories, such as service sets and
protective membranes, are listed in the respective accessories
section.
Special Mobile Panel accessories are listed in the following
section.
System components for SIMATIC HMI Mobile Panels can be
found directly under the respective Mobile Panel in the products
section.
Mobile Panel accessories
Siemens ST 80 / ST PC · 2013
2/99
2
© Siemens AG 2013
Operator panels
Mobile Panel accessories
Power supply unit
■ Overview
The external power supply for the Mobile Panel IWLAN is
intended for laboratory and office operation.
Suitable SITOP power supplies are available for use with
machinery and plants.
2
■ Technical specifications
6AV6671-5CN00-0AX2
6AV6671-5CN00-0AX2
Power pack, external,
Mobile Panel IWLAN
Power pack, external,
Mobile Panel IWLAN
Supply voltage
Type of supply voltage
100-240 V AC
Rated voltage/DC
12 V; Output side
Input current
Current consumption (rated value)
1.5 A; 50-60 Hz
Output current
each output
5A
Power
Output power
60 W
Interfaces
HMI-side interface
EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A)
Standards, approvals, certificates
CE
Connector 5.5 mm jack ( -) /
2.1 mm pin ( +) 12 V DC
Yes; EN61000-4-2,3,4,5,6,8,11
light industry level
Yes; UL69950, TÜVEN600950-1,
BSMI CNS14336,
CCC GB4942 approved
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
50 °C
-10 °C
Storage/transport temperature
• Min.
• max.
-20 °C
85 °C
Relative humidity
• max. relative humidity
90 %
Vibrations
• Vibration
• Frequency
2 g; 10 min./1 cycle
500 Hz; 10~500 Hz
Mechanics/material
Type of housing (front)
• Plastic
Yes
Dimensions
Width
125 mm
Height
50 mm
Thickness
31.5 mm
Weight
Weight without packaging
305 g
Scope of supply
Delivery unit in items
■ Ordering data
4; AC cable for EU, US, UK and JP
other
Note:
for Mobile Panel IWLAN
Note:
This catalog only includes accessories for current products.
6AV6671-5CN00-0AX2
Only suitable for operation under
laboratory/office conditions.
2/100
Number of sets
Order No.
Accessories for
Mobile Panel 277(F) IWLAN
Power supply unit, external,
Mobile Panel IWLAN
1; Incl. AC and DC connecting
cable
Siemens ST 80 / ST PC · 2013
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
© Siemens AG 2013
Operator panels
Mobile Panel accessories
Additional accessories
■ Overview
■ Technical specifications
Installation type/mounting
Mounting in portrait format
possible
6AV6574-1AG044AA0
Wall-mounting
bracket
Mobile Panel
Spare key
Mobile Panel
2
Yes
Mounting in landscape format
possible
No
Standards, approvals,
certificates
CE
Yes
Yes
55 °C
55 °C
0 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
90 %
90 %
Ambient conditions
Operating temperature
• Operating temperature range,
max.
• Operating temperature range,
min.
Wall-mounting bracket for Mobile Panel, front view
6AV6574-1AF044AA0
Mechanics/material
Sheet steel
Yes; Handle made
of plastic
Type of housing (front)
• Sheet steel
Yes; Powder-coated
Dimensions
Width
200 mm
35 mm
Height
230 mm
18 mm
Thickness
Depth
Weight
Weight without packaging
Spare keys for Mobile Panel
Scope of supply
Delivery unit in items
other
Note:
4 mm
25 mm;
Constructive
550 g; 880 g incl.
cable holder
30 g
1; Color: Black
10; Coupled with
key ring
Mobile Panel 170,
Mobile Panel 177,
Mobile Panel 277
IWLAN, Mobile
Panel 277F IWLAN,
without mounting
parts
For all
Mobile Panels with
key-operated switch
Moby D data card transponder
Siemens ST 80 / ST PC · 2013
2/101
© Siemens AG 2013
Operator panels
Mobile Panel accessories
Additional accessories
■ Ordering data
2
Order No.
Wall mounting bracket
for Mobile Panels
metal, without mounting accessories, suitable for all Mobile Panels
• 1 unit
6AV6574-1AF04-4AA0
Replacement keys
for Mobile Panels
metal/plastic, for all Mobile Panels,
two linked by keyring
• 10 units
6AV6574-1AG04-4AA0
SCALANCE
SCALANCE W-788 Access Points
IWLAN Access Points with built-in
wireless interface; wireless networks
IEEE 802.11b/g/a/h at 2.4/5 GHz to
54 Mbps; national approvals;
WPA2/AES; Power over Ethernet
(PoE), degree of protection IP65
(-20°C to +60°C);
scope of delivery: 2 ANT795-4MR
antennas, IP 67 hybrid connector,
installation material, manual on
CD-ROM, English/German
SCALANCE W788-2RR
IWLAN Dual Access Point with two
built-in radio interfaces for establishment of radio connections with iPCF
• National approvals for
operation outside the U.S.1) 2)
• National approvals for
operation within the U.S. 2)
SCALANCE W788-1PRO
IWLAN Access Point with
one built-in wireless interface
• National approvals for
operation outside the U.S. 1)
• National approvals for
operation within the U.S.
Order No.
SCALANCE W-786 Access Points
for SIMATIC Mobile Panel 277(F)
IWLAN
IWLAN Access Points with
integrated wireless interfaces;
wireless networks;
IEEE 802.11b/g/a/h at 2.4/5 GHz
up to 54 Mbps. National approvals;
WPA2/AES; Power over Ethernet
(PoE), degree of protection IP65
(-40 °C to +70 °C); scope of
delivery: Mounting hardware,
48 V DC terminal block; manual
on CD-ROM; English/German
SCALANCE W-786-2RR
IWLAN Dual Access Point with two
integrated wireless interfaces for
setting up radio connections with
iPCF; RJ45 connection
Four internal antennas
• National approvals for
operation outside the U.S.1) 2)
• National approvals for
operation within the U.S. 2)
6GK5786-2BA60-6AB0
SCALANCE W-786-1PRO
IWLAN Access Points with built-in
wireless interface RJ45 connection
6GK5788-2AA60-6AA0
6GK5788-2AA60-6AB0
6GK5788-1AA60-2AA0
6GK5788-1AA60-2AB0
Two internal antennas
• National approvals for
operation outside the U.S. 1)
• National approvals for
operation within the U.S.
1)
RoW version: "Rest of World" version: Version for sale worldwide, apart
from in the USA.
2)
Already prepared for rapid roaming (iPCF-MC); iPCF-MC is already
included as of SCALANCE FW version V4.3.37.
Siemens ST 80 / ST PC · 2013
6GK5786-1BA60-2AA0
6GK5786-1BA60-2AB0
SCALANCE W-784 Access Points
IWLAN Access Points with built-in
wireless interfaces;wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), IP30 degree of
protection (-20 °C to +60 °C);
scope of supply: Installation
material, 24 V DC terminal block;
manual on CD-ROM
English/German
SCALANCE W784-1
IWLAN Access Points with
one built-in wireless interface
• National approvals for
operation outside the U.S. 1)
• National approvals for
operation within the U.S.
2/102
6GK5786-2BA60-6AA0
6GK5784-1AA30-2AA0
6GK5784-1AA30-2AB0
© Siemens AG 2013
Operator panels
Mobile Panel accessories
Additional accessories
Order No.
■ Dimensional drawings
Further IWLAN Access Point
versions
SCALANCE W-786 Access Points
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI); wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protection IP65 (-40°C to +70°C); scope of
delivery: Installation material,
48 V DC terminal block; manual on
CD-ROM; English/German;
6GK5786-...
(see Catalog IK PI)
SCALANCE W-788 Access Points
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI); wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protection IP65 (-20°C to +60°C); scope of
delivery: 2 ANT795-4MR antennas,
IP67 hybrid plug-in connector,
installation material, manual on
CD-ROM, English/German
6GK5788-...
(see Catalog IK PI)
PS791-2DC power supply
24 V DC power supply for installation in SCALANCE W-786 products;
operating instructions in English/
German
6GK5791-2DC00-0AA0
PS791-2AC power supply
110 V AC to 230 V AC power supply
for installation in SCALANCE W-786
products; operating instructions in
English/German
6GK5791-2AC00-0AA0
8°
8°
100.7
2
2
G_ST80_XX_00047
6GK5784-1AA30-...
(see Catalog IK PI)
18
24.6
SCALANCE W-784 Access Points
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI), wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protection IP30 (-20 °C to +60 °C); scope
of delivery: Installation material,
24 V DC terminal block; manual on
CD-ROM; English/German;
225.2
■ Ordering data
SIMATIC Mobile Panel wall-mounting bracket
MOBY D accessories
MOBY D, MDS D100
6GT2600-0AD10
• 1 unit
Spacer
6GT2190-0AA00
• 1 unit
Fixing pocket
6GT2190-0AB00
• 1 unit
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Siemens ST 80 / ST PC · 2013
2/103
© Siemens AG 2013
Operator panels
SIMATIC HMI accessories
Connectors/converters/adapters
■ Overview
Components for the connection of SIMATIC HMI Panels
The range comprises connectors, adapters, converters, and
transducers.
An adapter can be used, for example, to mechanically rotate the
connector of a 9-pin panel plug by 90°. This may be beneficial
in confined spaces in the control desk or installation cabinet,
and is an easy way to provide additional flexibility.
2
Connectors/converters/adapters
A converter can be used to simulate a connection type that is
missing at the panel. In this way, for example, a TTY (20 mA) can
be generated from an RS422 signal, which is required for
connection to various types of PLC. Connectors are required for
power supply and I/O.
• 2-pin to n-pin connectors
• Converters
• Transducers
• Adapters for changing the cable outlet direction
• Bus connector
SIMATIC HMI accessories can also be used on non-Siemens
devices; see the technical specifications for more detailed information.
General SIMATIC HMI accessories are listed in this subsection;
the full range of SIMATIC HMI accessories is available in the Mall
and in our other online media.
2/104
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
HMI connecting components
■ Overview
2
RS 422 to RS 232 converter
Connector, female, 16-pin, I/O
RS 422 to TTY converter
Connector, female, 2x2-pin, jumpered internally
90 degree angle adapter, 1:1
Connector, female, 2-pin
For:
• Push Button Panels
• Key Panels
• Text Displays
• Operator Panels
• Touch Panels
• Multi Panels
•
•
•
•
•
Basic Panels
Comfort Panels
Mobile Panels
Thin Clients
Industrial USB Hub
Siemens ST 80 / ST PC · 2013
2/105
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
HMI connecting components
■ Technical specifications
2
6AV6671-8XA00-0AX0
6ES7193-4JB00-0AA0
Connector, female, 2-pin
Connector, female, 2x2-pin
Installation type/mounting
Wall mounting/direct mounting possible
Yes; can be plugged into SIMATIC HMI device
Yes; can be plugged into SIMATIC HMI device
Supply voltage
Rated voltage/DC
24 V; DC
24 V; DC
Interfaces
Number of pins HMI-side
2; Female
2; Outgoing side jumpered internally, color-coded
Number of pins device-side
2; Female, screw terminals
4; Female, spring-loaded terminals, 0.75 mm2
Standards, approvals, certificates
CE
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
95 %
95 %
Mechanics/material
Screw type
• 4.5 V
Yes
Type of housing (front)
• Plastic
Yes
Yes
Dimensions
Width
10 mm
10 mm
Height
15 mm
22 mm
Thickness
27 mm
25 mm
Scope of supply
Delivery unit in items
10
10
other
Note:
for SIMATIC HMI Panels, except for Key Panel
for ET 200S, interface module, KP32F, PN-to-PN coupler
6AV6671-3XY38-4AX0
6AV6671-3XY48-4AX0
6AV6671-3XY58-4AX0
Connector, female, 12-pin
Connector, female, 16-pin
Connector, female, 24-pin
Yes; can be plugged into
SIMATIC HMI device
Yes; can be plugged into
SIMATIC HMI device
Yes; can be plugged into
SIMATIC HMI device
Supply voltage
Rated voltage/DC
24 V; DC
24 V; DC
24 V; DC
Interfaces
Number of pins HMI-side
12; Female
16; Female
24; Female
Number of pins device-side
12; Female, spring-loaded terminals
16; Female, spring-loaded
terminals, 0.75 mm2
24; Female, spring-loaded
terminals, 0.75 mm2
Standards, approvals, certificates
CE
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
95 %
95 %
95 %
Mechanics/material
Type of housing (front)
• Plastic
Yes
Yes
Yes
Installation type/mounting
Wall mounting/direct mounting possible
2/106
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
HMI connecting components
■ Technical specifications (continued)
6AV6671-3XY38-4AX0
6AV6671-3XY48-4AX0
6AV6671-3XY58-4AX0
Connector, female, 12-pin
Connector, female, 16-pin
Connector, female, 24-pin
Dimensions
Width
16 mm
16 mm
16 mm
Height
20 mm
28 mm
54 mm
Thickness
20 mm
20 mm
20 mm
Scope of supply
Delivery unit in items
10; Without ejector
10; Without ejector
4; Without ejector
other
Note:
for KP8 PN
for KP8F PN, KP32F PN
for KP32F PN
6AV6671-8XE00-0AX0
6AV6671-8XJ00-0AX0
6AV6671-8XD00-0AX0
Converter, RS 422 to RS 232
Converter RS 422 to TTY
90 degree angle adapter, 1:1
Installation type/mounting
Wall mounting/direct mounting possible
Yes; Can be screwed onto the HMI
Yes; Can be screwed onto the HMI
Yes; Can be screwed onto the HMI
Interfaces
Number of pins HMI-side
9; Pin (RS422)
9; Pin (RS422)
9; Male
Number of pins device-side
9; Pin (RS232)
15; Socket (TTY)
9; Female
Standards, approvals, certificates
CE
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
95 %
95 %
95 %
Mechanics/material
Screw type
• 4.5 V
Yes; HMI page
Yes; HMI page
Yes; HMI page
Yes
Yes
Type of housing (front)
• Plastic
• Cast light alloy
2
Yes
Dimensions
Width
31 mm
42 mm
31 mm
Height
50 mm
62 mm
25 mm
Thickness
11 mm
11 mm
25 mm
Weight
Weight without packaging
26 g
28 g
34 g
Scope of supply
Delivery unit in items
1
1
1
suitable for all SIMATIC HMI RS422
interfaces, for details refer to the
operating instructions of the
respective device
suitable for all SIMATIC HMI RS422
interfaces, for details refer to the
operating instructions of the
respective device
suitable for all appropriate interfaces
other
Note:
Siemens ST 80 / ST PC · 2013
2/107
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
HMI connecting components
■ Ordering data
Order No.
Connectors
24 V DC connector (2-pin)
2
Order No.
Converters
6AV6671-8XA00-0AX0
for all SIMATIC HMI Panels, without
screw mounting, loop-through not
possible.
Approved for all SIMATIC HMI
Panels except Key Panels.
24 V DC connector (2-pin)
(can be looped through)
6ES7193-4JB00-0AA0
6AV6671-3XY38-4AX0
6AV6671-8XJ00-0AX0
Adapters
90 degree angle adapter
6AV6671-3XY48-4AX0
16-pin, 24 V DC for
SIMATIC HMI Key Panel KP8F PN
and Key Panel KP32F PN
24-pin cable connector
RS422 to TTY converter
9-pin male contact (on HMI) to
15-pin female contact, to be
screwed onto HMI RS422 interface,
180 degree cable outlet,
for the connection to SIMATIC S5
12-pin, 24 V DC for
SIMATIC HMI Key Panel KP8 PN
16-pin cable connector
6AV6671-8XE00-0AX0
9-pin male contact (on HMI) to 9-pin
male contact, to be screwed onto
HMI RS422 interface, cable outlet
180 degrees, for connection of
non-Siemens PLC
for all SIMATIC HMI Panels, without
screw mounting, loop through possible, even if connecter unplugged.
Approved for Key Panels.
12-pin cable connector
RS422 to RS232 converter
6AV6671-8XD00-0AX0
9-pin male contact (on HMI) to 9-pin
female contact, 1:1 connection, to
be screwed onto the RS485/422/232
HMI interface, or any other suitable
interface
6AV6671-3XY58-4AX0
24-pin, 24 V DC for
SIMATIC HMI Key Panel KP32F PN
Note:
Delivery units/quantities are specified in the applicable technical
data.
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
2/108
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
RS485 bus connector
■ Overview
• Used for connecting PROFIBUS nodes to the PROFIBUS bus
cable
• Easy installation
• FastConnect plugs ensure extremely short assembly times
due to their insulation-displacement technology
• Integrated terminating resistors (not in the case of
6ES7 972-0BA30-0XA0)
• Connectors with Sub-D socket permit PG connection without
the additional installation of network nodes
■ Ordering data
RS485 bus connector
with axial cable outlet (180°)
Order No.
6GK1500-0EA02
For industrial PC, SIMATIC HMI OP,
OLM; max. transmission rate
12 Mbit/s
SIPLUS DP PB RS485 connector
with axial cable outlet (180°)
6AG1500-0EA02-2AA0
RS485 bus connector
with cable outlet (90°)
6ES7972-0BA12-0XA0
6ES7972-0BB12-0XA0
SIPLUS DP PB RS485 connector
with 90° cable outlet
For extended temperature range
-25 … + 60 °C
• without PG interface
Based on 6ES7 972-0BA12-0XA0
• with PG interface
Based on 6ES7 972-0BB12-0XA0
6AG1972-0BA12-2XA0
6AG1972-0BB12-2XA0
6ES7972-0BA42-0XA0
6ES7972-0BB42-0XA0
SIPLUS DP PB RS485 connector
with inclined cable outlet (35°)
For extended temperature range
-25 … + 60 °C
• without PG interface
Based on 6ES7 942-0BA42-0XA0
• with PG interface
Based on 6ES7 942-0BB42-0XA0
RS485 bus connector
with cable outlet (30°)
With screw-terminals,
low-cost variant,
max. transmission rate 1.5 Mbit/s
With insulation displacement, max.
transmission rate 12 Mbps
Without PG interface
• 1 unit
• 100 units
6ES7972-0BA52-0XA0
6ES7972-0BA52-0XB0
With PG interface
• 1 unit
• 100 units
6ES7972-0BB52-0XA0
6ES7972-0BB52-0XB0
Without PG interface, grounding
via control cabinet cover
• 1 unit
6ES7972-0BA70-0XA0
With PG interface, grounding
via control cabinet cover
• 1 unit
6ES7972-0BB70-0XA0
PROFIBUS FastConnect RS485
bus connector with angled cable
outlet (35°)
With insulation displacement,
max. transmission rate 12 Mbps
• without PG interface
• with PG interface
RS485 bus connector
with angled cable outlet (35°)
With screw-terminals, max.
transmission rate 12 Mbit/s
• without PG interface
• with PG interface
PROFIBUS bus connector RS485
with FastConnect technology
PROFIBUS FastConnect bus connector RS485 with 90° cable outlet
For medial stress;
Based-on 6GK1 500-0EA02
With screw-terminals, max. transmission rate 12 Mbit/s
• without PG interface
• with PG interface
Order No.
6AG1972-0BA42-7XA0
6AG1972-0BB42-7XA0
6ES7972-0BA30-0XA0
PROFIBUS FastConnect
bus connector RS485 Plug 180
6ES7972-0BA60-0XA0
6ES7972-0BB60-0XA0
6GK1500-0FC10
With insulation displacement
terminals, with 180° cable outlet,
for industrial PC, SIMATIC HMI OP,
OLM; max. transmission rate
12 Mbit/s
SIMATIC S5/S7 plug-in cable for
PROFIBUS
6ES7901-4BD00-0XA0
Preassembled with two 9-pin sub-D
connectors; max. transmission rate
12 Mbit/s; 3 m
SIMATIC NET Manual Collection
6GK1975-1AA00-3AA0
Electronic manuals for communication systems, communication protocols, and communication products;
on DVD; German/English
Siemens ST 80 / ST PC · 2013
2/109
2
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
IE FC RJ45 Plug 2 x 2
■ Overview
• Implementation of direct device connections over distances of
up to 100 m with Industrial Ethernet FC installation cable 2 x 2
without patching
• Easy connection (insulation displacement contacts) for 4-core
Twisted Pair installation cables (100 Mbit/s) without the need
for special tools
• Error-preventing connection technique thanks to visible
connection area as well as colored blade terminals
• Industry-compatible design (rugged metal housing, no easily
lost small parts)
• Excellent EMC shielding and deflection (metal housing)
• Integrated strain-relief for installation cables
• Compatible to the EN 50173 (RJ45) / ISO IEC 11801 standard
• Additional strain and bending relief of plug connector possible
through latching of plug on device housing, e.g. with
SCALANCE X, SCALANCE S, ET 200S.
2
■ Ordering data
Order No.
IE FC RJ45 plugs
Order No.
IE FC TP Standard Cable GP 2 x 2
(Type A)
RJ45 plug connector for Industrial
Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting
Industrial Ethernet FC installation
cables
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug;
PROFINET-compatible;
with UL approval;
IE FC RJ45 Plug 180
Sold by the meter
180° cable outlet; for network
components and CPs/CPUs with
Industrial Ethernet interface
• 1 pack = 1 unit
• 1 pack = 10 units
• 1 pack = 50 units
max. length 1,000 m;
minimum order 20 m
6GK1901-1BB10-2AA0
6GK1901-1BB10-2AB0
6GK1901-1BB10-2AE0
IE FC RJ45 Plug 90
90° cable outlet; e.g. for ET 200S
• 1 pack = 1 unit
• 1 pack = 10 units
• 1 pack = 50 units
6GK1901-1BB20-2AA0
6GK1901-1BB20-2AB0
6GK1901-1BB20-2AE0
IE FC RJ45 Plug 145
145° cable outlet; e.g.
for SIMOTION and SINAMICS
• 1 pack = 1 unit
• 1 pack = 10 units
• 1 pack = 50 units
6GK1901-1BB30-0AA0
6GK1901-1BB30-0AB0
6GK1901-1BB30-0AE0
IE FC stripping tool
6GK1901-1GA00
Preadjusted stripping tool for fast
stripping of Industrial Ethernet FC
cables
2/110
Siemens ST 80 / ST PC · 2013
Preferred length
• 1000 m
IE FC TP Flexible Cable GP 2 x 2
(Type B)
6XV1840-2AH10
6XV1840-2AU10
6XV1870-2B
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for occasional movement;
PROFINET-compatible;
with UL approval;
sold by the meter; max. length
1000 m, minimum order 20 m
IE FC TP Trailing Cable GP 2 x 2
(Type C)
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for use in trailing cables;
PROFINET-compatible;
with UL approval;
sold by the meter; max. length
1000 m, minimum order 20 m
6XV1870-2D
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
IE FC RJ45 Plug 2 x 2
■ Ordering data
IE FC TP Trailing Cable 2 x 2
(Type C)
Order No.
6XV1840-3AH10
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90
for use in trailing cables;
PROFINET-compatible;
without UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE TP Torsion Cable GP 2 x 2
(Type C)
6XV1870-2F
6XV1840-4AH10
IE FC TP Food Cable GP 2 x 2
(Type C)
2
6XV1871-2L
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90
for the food and beverages industry;
PROFINET-compliant;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC Blade Cassettes (5 mm)
6GK1901-1GB01
Replacement blade cassette for the
Industrial Ethernet stripping tool;
for use with IE FC RJ45 Plugs and
Modular Outlet,
5 items
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45
Plug 180/90; marine approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC TP FRNC Cable GP 2 x 2
(Type B)
6XV1871-2S
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90 for use in
festoon applications;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for use with robots; PROFINETcompatible; with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC TP Marine Cable 2 x 2
(Type B)
Order No.
IE FC TP Festoon Cable GP 2 x 2
(Type B)
6XV1871-2F
4-core, shielded, halogen-free TP
installation cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for occasional movement;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
Siemens ST 80 / ST PC · 2013
2/111
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Connecting cables
■ Overview
2
Example - connecting cables
Connecting cable PN (PROFINET) for Mobile Panels
Key
P = PROCESS COUPLING
K = optional process coupling (option required)
D = DOWNLOAD (update operating system, project, …)
U = booting (factory setting in the case of a missing or damaged
operating system)
MBP = Mobile Panel
You can find order numbers for the connecting cables required
to link SIMATIC Panels under ordering data.
Connecting cable DP (PROFIBUS) for Mobile Panels
2/112
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Connecting cables
■ Overview (continued)
Overview of SIMATIC HMI connection options
RS 232 external
(15/9-pole)
TD-PPI
(incl. voltage)
RS 232
Null modem
RS 232/PPI
multi-master
cable
USB/PPI
multi-master
cable
MPI (PG-S7)
up to
187.5 kbaud
6XV1 440-2Kxxx
6ES7 9013EB10-0XA0
6ES7 9011BF00-0XA0
6ES7 9013CB30-0XA0
6ES7 9013DB30-0XA0
6ES7 9010BF00-0AA0
Key Panel KP8/KP8F, KP32F
-
-
-
-
-
-
PP7, PP17-I, PP17-II
-
-
-
-
-
-
KTP400 Basic mono PN
-
-
-
-
-
-
KTP600 Basic mono PN
-
-
-
-
-
-
KTP600 Basic color DP
-
-
-
D/U
D/U
P/D
KTP600 Basic color PN
-
-
-
-
-
-
KTP1000 Basic color DP
-
-
-
D/U
D/U
P/D
KTP1000 Basic color PN
-
-
-
-
-
-
KTP1500 Basic color PN
-
-
-
-
-
-
K(T)P400 Comfort
-
-
-
-
-
P/D
K(T)P700 - KP1500 Comfort
-
-
-
-
-
P/D
TP700 -TP2200 Comfort
-
-
-
-
-
P/D
MBP 177
-
-
-
D/U
-
-
MBP 277
-
-
-
D/U
-
-
TD200
-
P
-
D/U
-
P
TD400C
-
P
-
D/U
-
P
OP73micro
-
P
-
D/U
D/U
P
TP177micro
-
-
-
D/U
D/U
-
OP73
-
P
-
D/U
D/U
P/D
OP77A
-
-
-
D/U
D/U
P/D
OP77B
P
-
D/U
-
-
P/D
TP177A
-
-
-
D/U
D/U
P/D
TP177B
P 1)
-
-
D/U
-
P/D
TP177B 4"
P 1)
-
D
D
-
P/D
OP177B
P 1)
-
-
D/U
-
P/D
TP277-6
P 1)
-
-
D/U
-
P/D
OP277-6
P 1)
-
-
D/U
-
P/D
MP177-6 T
P 1)
-
-
D/U
-
P/D
MP277-8 T
P 1)
-
-
D/U
-
P/D
MP277-10 T
P 1)
-
-
D/U
-
P/D
MP377-12 T
P 1)
-
-
D
-
P/D
MP377-15 T
P 1)
-
-
D
-
P/D
MP377-19 T
1)
-
-
D
-
P/D
1)
P
2
Only in conjunction with the RS 422/232 converter
Siemens ST 80 / ST PC · 2013
2/113
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Connecting cables
■ Overview (continued)
DP PtP
6XV1 8300Axxx
2
DP
Standard
DP
(Mobile
Panel)
PN (cross
cable) 2)
PN
(standard
cable) 2)
PN
(Mobile
Panel)
RS 422 to
RS 232
converter
RS 232 to
TTY
converter
(20 mA)
90° angular
(9-pin 1:1)
Standard
PROFIBUS
(2-contact)
6XV1 4404Axxx
6XV1 8703RH20
Standard
Ethernet
CAT5
6XV1 4404Bxxx
6AV6 6718XE000AX0
6ES5 7341BD20
6AV6 6718XD000AX0
Point-topoint
Key Panel KP8/KP8F, KP32F
-
-
-
P/D
P/D
-
-
-
-
PP7, PP17-I, PP17-II
P
P
-
-
-
-
-
-
-
KTP400 Basic mono PN
-
-
-
P/D/U
P/D/U
-
-
-
-
KTP600 Basic mono PN
-
-
-
P/D/U
P/D/U
-
-
-
-
KTP600 Basic color DP
P/D
P/D
-
-
-
-
-
-
P/D/U
KTP600 Basic color PN
-
-
-
P/D/U
P/D/U
-
-
-
-
KTP1000 Basic color DP
P/D
P/D
-
-
-
-
-
-
P/D/U
KTP1000 Basic color PN
-
-
-
P/D/U
P/D/U
-
-
-
-
KTP1500 Basic color PN
-
-
-
P/D/U
P/D/U
-
-
-
-
K(T)P400 Comfort
P/D
P/D
-
P/D/U
P/D/U
-
-
-
P/D/U
K(T)P700 - TP1500 Comfort
P/D
P/D
-
P/D/U
P/D/U
-
-
-
P/D/U
TP700 -TP2200 Comfort
P/D
P/D
-
P/D/U
P/D/U
-
-
-
P/D/U
MBP 177 DP
P/D
P/D
P/D
-
-
-
-
-
-
MBP 177 PN
-
-
-
-
-
P/D
-
-
-
MBP 277
P/D
P/D
P/D
-
-
P/D
-
-
-
TD200
-
-
-
-
-
-
-
-
-
TD400C
-
-
-
-
-
-
-
-
-
OP73micro
P
-
-
-
-
-
-
-
-
TP177micro
P
P
-
-
-
-
-
-
P/D/U
OP73
P
P
-
-
-
-
-
-
-
OP77A
P
P
-
-
-
-
-
-
P/D/U
OP77B
P/D
P/D
-
-
-
-
-
P
P/D/U
TP177A
P
P
-
-
-
-
-
-
P/D/U
TP177B DP
P/D
P/D
-
-
-
-
P
P 4)
P/D/U
TP177B PN/DP
P/D
P/D
-
P/D
P/D
-
P
P 4)
P/D/U
TP177B 4"
P/D
P/D
-
P/D/U
P/D/U
-
P
P 4)
P/D/U
OP177B DP
P/D
P/D
-
-
-
-
P
P 4)
P/D/U
OP177B PN/DP
P/D
P/D
-
P/D
P/D
-
P
P 4)
P/D/U
TP277-6
P/D
P/D
-
P/D
P/D
-
P
P 4)
P/D/U
OP277-6
P/D
P/D
-
P/D
P/D
-
P
P 4)
P/D/U
MP177-6 T
P/D
P/D
-
P/D
P/D
-
P
P 4)
P/D/U
MP277-8 T
P/D
P/D
-
P/D
P/D
-
P
P 4)
P/D/U
4)
P/D/U
MP277-8 K
P/D
P/D
-
P/D
P/D
-
P
P
MP277-10 T
P/D
P/D
-
P/D
P/D
-
P
P 4)
P/D/U
MP277-10 K
P/D
P/D
-
P/D
P/D
-
P
P 4)
P/D/U
MP377-12 T
P/D
P/D
-
P/D/U
P/D/U
-
P
P 4)
P/D
MP377-12 K
P/D
P/D
-
P/D/U
P/D/U
-
P
P 4)
P/D
MP377-15 T
P/D
P/D
-
P/D/U
P/D/U
-
P
P 4)
P/D
MP377-19 T
P/D
P/D
-
P/D/U
P/D/U
-
P
P 4)
P/D
Note:
This table is for basic orientation only. Technical characteristics
are described in the communication manual or the respective
user manual:
1)
With gender changer
2)
PROFINET IRT (Isochronous Runtime); isochronous mode only possible
with IRT-enabled switch
3)
Only in conjunction with the RS422/RS232 converter
6AV6 671-8XE00-0AX0
4)
WinCC flexible 2008 SP2 and higher
2/114
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Connecting cables
■ Ordering data
Order No.
Connecting cables
SIMATIC S7 connecting cables
MPI cable
6ES7901-0BF00-0AA0
Between SIMATIC S7 and
programming device via MPI max.
187.5 kBaud, standard length 5.0 m
Connecting cable
6ES7901-1BF00-0XA0
Between HMI adapter and PC/TS
Adapter (RS 232 cable/null-modem
cable) for OP 77B, TP 177A/B,
OP 177B, standard length 5.0 m
Connecting cables 6XV1440-2A 2)
6XV1440-2A…
Connecting cable between
TD/TP/OP and AG S5 95U to -155U,
1000 m max.
PROFIBUS connecting cable
830-1T
For connection of data terminals,
preassembled with two sub-D connectors, 9-pin terminated at both
ends
for PP, OP 73micro, OP 73,
TP 177micro, OP 77A/B, TP 177A,
TP/OP 177B
• 1.5 m
• 3.0 m
6XV1830-1CH15
6XV1830-1CH30
USB/PPI multi-master cable
6ES7901-3DB30-0XA0
Crossed TP cable 4 x 2, preassembled with 2 x RJ45 connectors
• 1.0 m
• 6.0 m
• 10.0 m
6XV1870-3RH10
6XV1870-3RH60
6XV1870-3RN10
2
DP connecting cable
(MPI/PROFIBUS)
For wired Mobile Panels 177,
Mobile Panels 277,
standard lengths
•2m
•5m
•8m
• 10 m
• 15 m
• 20 m
• 25 m 1)
6XV1440-4AH20
6XV1440-4AH50
6XV1440-4AH80
6XV1440-4AN10
6XV1440-4AN15
6XV1440-4AN20
6XV1440-4AN25
PN connecting cable (PROFINET)
For connecting the S7-200 to the
serial PC/OP interface
Standard length 5 m
PROFIBUS FC Standard Cable 2)
Order No.
Industrial Ethernet TP XP Cord
RJ45/RJ45
For wired Mobile Panels 177,
Mobile Panels 277, standard lengths
•2m
•5m
•8m
• 10 m
• 15 m
• 20 m
• 25 m 1)
6XV1440-4BH20
6XV1440-4BH50
6XV1440-4BH80
6XV1440-4BN10
6XV1440-4BN15
6XV1440-4BN20
6XV1440-4BN25
6XV1830-0E…
For connection to PPI;
standard type with special design
for quick mounting, 2-core,
shielded, sold by the meter,
max. delivery unit 1000 m,
minimum ordering quantity 20 m
1)
Instead of using longer cables, we recommend that you use additional
connection boxes, see length code in catalog appendix.
2)
See length code in catalog appendix.
Note:
Cable pin assignments can be found on the Internet in the online
help of WinCC flexible and under FAQs
http://support.automation.siemens.com
This catalog only includes accessories for current products. The
complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Siemens ST 80 / ST PC · 2013
2/115
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Memory media
■ Overview
SIMATIC HMI memory media are suitable for industry and
optimized for the requirements in industrial environments.
Special formatting and write logarithms ensure fast read/write
cycles and a long service life of the memory cells.
• Push Button Panels
• Operator Panels
• Touch Panels
• Multi Panels
• Comfort Panels
• Mobile Panels
• Industrial USB Hub
2
Memory media
■ Technical specifications
6AV6671-1CB000AX2
6AV6671-8XB100AX1
6AV2181-8XP000AX0
6AV6574-2AC002AA1
6ES7 648-0DC500AA0
SIMATIC HMI
MM memory card,
128 MB
SIMATIC HMI
SD memory card,
512 MB
SIMATIC HMI
SD memory card,
2 GB
SIMATIC HMI
CF memory card,
512 MB
SIMATIC IPC USB
FLASH DRIVE,
bootable, 8GB
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Supply voltage
Type of supply voltage
DC
DC
DC
DC
DC
Rated voltage/DC
3.3 V
3.3 V
3.3 V
3.3 V
5.5 V
Input current
Current consumption
(rated value)
60 mA
60 mA
60 mA
75 mA
60 mA
Memory
Type of memory
Multi Media Card
Secure Digital
memory card
Secure Digital
memory card
CompactFlash
memory CF type I
USB flash drive
Size
128 Mbyte
512 Mbyte
2 048 Mbyte
512 Mbyte
8 192 Mbyte
Standards, approvals,
certificates
CE
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
55 °C
5 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-40 °C
70 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
90 %
85 %
Mechanics/material
Type of housing (front)
• Plastic
Yes
Yes
Yes
Yes
Yes
Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible
2/116
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Memory media
■ Technical specifications (continued)
6AV6671-1CB000AX2
6AV6671-8XB100AX1
6AV2181-8XP000AX0
6AV6574-2AC002AA1
6ES7 648-0DC500AA0
SIMATIC HMI
MM memory card,
128 MB
SIMATIC HMI
SD memory card,
512 MB
SIMATIC HMI
SD memory card,
2 GB
SIMATIC HMI
CF memory card,
512 MB
SIMATIC IPC USB
FLASH DRIVE,
bootable, 8GB
Dimensions
Width
24 mm
24 mm
24 mm
42.8 mm
16.7 mm
Height
32 mm
32 mm
32 mm
36.4 mm
59.1 mm
Thickness
2.1 mm
2.1 mm
2.1 mm
3.3 mm
7 mm
Weight
Weight without packaging
3g
3g
3g
10 g
12 g
Scope of supply
Delivery unit in items
1
1
1
1
1
for OP 77B, TP177B,
OP 177B, TP 277,
OP 277, C7-635,
MP 177, MP 277,
MP 377,
Mobile Panel 177,
Mobile Panel 277,
Comfort Panel
for MP 177,
MP 277, MP 377 and
Mobile Panel 277,
WinCC flexible 2008
SP1 and higher for
OP 77, TP/OP 177,
TP/OP 277,
Mobile Panel 177,
with SD/MMC slot
For all
Comfort Panels
for SIMATIC HMI
Panels and IPCs with
CF slot
for SIMATIC HMI
devices with USB slot
and SIMATIC IPC,
with installed
SIMATIC IPC BIOS
Manager
other
Note:
■ Ordering data
SIMATIC HMI MM memory card
128 MB
Order No.
6AV6671-1CB00-0AX2
6AV6671-8XB10-0AX1
For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI SD memory card
2 GB
Note:
For delivery units/amounts, see the technical data for the
relevant product.
For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI SD memory card
512 MB
2
6AV2181-8XP00-0AX0
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI CF memory card
512 MB
6AV6574-2AC00-2AA1
For contents and matching devices,
see Technical Data in the Mall
PC card adapter
for CF memory card
6AV6574-2AF00-8AX0
For contents and matching devices,
see Technical Data in the Mall
PC memory card, 512 MB
6AV6574-2AC00-2AF1
For contents and matching devices,
see Technical Data in the Mall
SIMATIC IPC USB flash drive 8 GB
6ES7648-0DC50-0AA0
For contents and matching devices,
see Technical Data in the Mall
SIMATIC memory module for
Push Button Panel
6ED1056-1BA00-0AA0
For contents and matching devices,
see Technical Data in the Mall
Siemens ST 80 / ST PC · 2013
2/117
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Service sets
■ Overview
Service sets are available for the product groups listed below:
• Push Button Panels
• Key Panels
• Operator Panels
• Touch Panels
• Multi Panels
• Basic Panels
• Comfort Panels
• Mobile Panels
• Industrial USB Hub
2
■ Technical specifications
6AV6671-2EA000AX0
6AV6675-3AA000AX0
6AV6671-4CA000AX0
6AV6574-1AA044AA0
6AV6671-5CA000AX2
6AV6671-3EA010AX0
Service set 4"
and 6" devices
Service set 10"
devices, Type 2
Service set 15"
devices
Service set
Mobile Panel
Service set
Mobile Panel
277(F)
IWLAN V2
Service set
Industrial USB
Hub 4
Battery
Design
• Special design
Yes;
Spare 3.6 V
1.5 Ah backup
battery included
in the package
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
95 %
95 %
95 %
95 %
95 %
95 %
2/118
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Service sets
■ Technical specifications (continued)
6AV6671-2EA000AX0
6AV6675-3AA000AX0
6AV6671-4CA000AX0
6AV6574-1AA044AA0
6AV6671-5CA000AX2
6AV6671-3EA010AX0
Service set 4"
and 6" devices
Service set 10"
devices, Type 2
Service set 15"
devices
Service set
Mobile Panel
Service set
Mobile Panel
277(F)
IWLAN V2
Service set
Industrial USB
Hub 4
1; Content: 2 x
seal KTP 400-TP
177B 4", 2 x seal
for KTP 600, 7 x
aluminum mounting clip, 1 x 2-pin
female connector
1; Content:
1 x mounting
seal, 10 x cast
aluminum mounting clip, 1 x 2-pin
female connector
1; Content:
1 x mounting
seal, 1 x memory
card lock,
12 x cast aluminum mounting
clip, 1 x 2-pin
female connector,
1 x Allen key
1; Content:
1 x blanking plug,
2 x PG cable
gland A-Box,
2 x 12-pole terminal box,
1 x 3-pole terminal box,
1 x blanking
cover A-Box,
2 x corner seal l/r
and O-ring, 4 x
decorative film for
corner seal l/r
1; Content:
2 x charging station cover l/r,
1 x charging station connector,
2 x corner seal l/r,
2 x gasket corner seal, 4 x
decorative film
corner seal l/r,
1 x battery incl.
cover, 1 x spare
key
1; Content:
1 x mounting
seal, 1 x mounting frame, 5 x
plastic mounting
clip, 1 x 2-pin
female connector
for KTP 400
for MP 277 10"
Basic, KTP 600
Touch with stainBasic, TP 177B 4" less steel front
for MP 377 15"
Touch with stainless steel front
for Mobile Panel
170, Mobile Panel
177
for Mobile Panel
277 IWLAN V2,
Mobile Panel
277F IWLAN V2
For the Industrial
USB Hub 4
6AV3678-3XC30
6AV3678-1CC10
6AV6671-1XA000AX0
6AV6574-1AA004AX0
6AV2181-8XA800AX0
6AV6671-2XA000AX0
Service set
Push Button
Panel
Service set
TD17, OP7/17
Service set
OP73micro,
OP73, OP77
Service set 6"
devices, Type 1
Service set 6"
devices, Type 2
Service set 6"
devices, Type 3
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
95 %
95 %
95 %
95 %
95 %
95 %
1; Content:
1 x mounting seal
PP7, 1 x mounting seal PP17, 5
x plastic mounting clip, 1 x 2-pin
female connector,
1 x 3-pin female
connector, 1 x
4-pin female connector, 2 x 16-pin
female connector
1; Content:
1 x mounting seal
TD17, 1 x mounting seal OP7,
1 x mounting seal
TD/OP17,
5 x plastic
mounting clip
1; Content:
1 x mounting seal
OP73, 1 x mounting seal OP77,
4 x plastic mounting clip, 1 x 2-pin
female connector
1; Content:
3 x mounting
seal, 2 x labeling
strip, 7 x plastic
mounting clip,
1 x 2-pin female
connector
1; Content:
3 x mounting
seal, 2 x labeling
strip, 7 x plastic
mounting clip,
20 x aluminum
mounting clip,
1 x 2-pin female
connector
1; Content:
1 x mounting seal
TP 177, 1 x
mounting seal
OP 177, 7 x plastic mounting clip,
1 x 2-pin female
connector
for PP7, PP17-I,
PP17-II
for TD17, OP7,
OP17
for OP73micro,
OP73, OP77A,
OP77B
for TP 070, TP
170A/B, OP
170B, TP
170micro, OP
270 6", TP 270 6",
MP 270B 6"
Touch
for TP 070, TP
170A/B, OP
170B, TP
170micro, OP /TP
270 6", MP 177
6"T, MP 270B 6"
Touch
for TP 177micro,
TP 177A, TP
177B, OP 177B
Scope of supply
Number of sets
other
Note:
Scope of supply
Number of sets
other
Note:
Siemens ST 80 / ST PC · 2013
2/119
2
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Service sets
■ Technical specifications (continued)
2
6AV65741AA00-2CX0
6AV65741AA00-2DX0
6AV66713XA01-0AX0
6AV66713XA01-0AX1
6AV65741AA00-2BX0
6AV66714XA00-0AX0
6AV66715CA00-0AX1
Service set
10" to 15"
devices
Service set
10" devices,
Type 1
Service set
6" to 10"
devices
Service set
8" to 10"
devices
Service set
12" devices
Service set
12" to 19"
devices
Service set
Mobile Panel
277 (F)
IWLAN V1
Battery
Design
• Special design
Yes; Spare
battery
included in the
package
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
95 %
95 %
95 %
95 %
95 %
95 %
95 %
1; Content:
2 x mounting
seal,
7 x mounting
clip, 1 x 2-pin
female connector,
1 x CF card
lock, 1 x
PC card lock
1; Content:
1 x slide-in
labels OP 270
10" and MP
270 10" Key,
1 x mounting
seal OP 270
10" and MP
270 10" Key,
10 x cast aluminum mounting clip, 1 x
2-pin female
connector
1; Content:
6 x devicespecific seal,
15 x aluminum mounting
clip, 1 x 2-pin
female connector
1; Content:
14 x spring
mounting clip,
1 x connector,
female, 2-pin
1; Content:
2 x labeling
strip, 6 x aluminum mounting clip, 1 x
2-pin female
connector,
2 x memory
card lock
1; Content:
1 x mounting
seal MP 377
12" Key, 1 x
mounting seal
MP 377 12"
Touch, 1 x
mounting seal
MP 377 15"
Touch, 1 x
mounting seal
MP 377 19"
Touch, 18 x
aluminum
mounting clip,
1 x 2-pin
female connector
1; Content:
2 x charging
station cover
l/r, 1 x charging station
connector, 2 x
corner seal l/r,
2 x gasket corner seal, 4 x
decorative film
corner seal l/r,
1 x battery
incl. cover, 1 x
spare key
for C7-636
Touch, TP270
10", MP270B
10" Touch,
MP370 12"
Touch, MP370
15" Touch
for OP 270 10",
MP 270B Key
for TP/OP 277
6", MP 277 8"
Touch, MP 277
8" Key, MP 277
10" Key product version "ES
14" and later,
MP 277 10"
Touch product
version "ES 14"
and later
for MP 277 8"
Touch, MP 277
8" Key product version "ES
15" and later,
MP 277 10"
Touch product
version "ES 15"
and later
for MP 370 12"
Key
for MP 377 12"
Key, MP 377
12" Touch,
MP 377 15"
Touch, MP 377
19" Touch
for Mobile
Panel 277
IWLAN, Mobile
Panel 277F
IWLAN
Scope of supply
Number of sets
other
Note:
2/120
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Service sets
■ Ordering data
Service set for 4" and 6" devices
Order No.
6AV6671-2EA00-0AX0
For contents and matching devices,
see Technical Data
Service set for 10" devices, Type 2
6AV6675-3AA00-0AX0
6AV6671-4CA00-0AX0
6AV6574-1AA04-4AA0
6AV6671-5CA00-0AX2
For contents and matching devices,
see Technical Data in the Mall
Service set for 10", Type 1
6AV6574-1AA00-2CX0
6AV6574-1AA00-2DX0
6AV6574-1AA00-2BX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 12" to 19" devices
6AV6671-1XA00-0AX0
6AV6671-3XA01-0AX1
For contents and matching devices,
see Technical Data in the Mall
Service set for 12" devices
6AV3678-1CC10
6AV6671-3XA01-0AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 8" to 10" devices
6AV3678-3XC30
For contents and matching devices,
see Technical Data in the Mall
Service set for OP73 micro, OP73,
OP77
Service set for 10" to 15" devices
Service set for 6" to 10" devices
6AV6671-3EA01-0AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for TD17, OP7/17
2
6AV6671-2XA00-0AX0
For contents and matching devices,
see Technical Data in the Mall
For contents and matching devices,
see Technical Data
Service set for pushbutton panel
Service set for 6" devices, Type 3
For contents and matching devices,
see Technical Data in the Mall
For contents and matching devices,
see Technical Data
Service Kit Industrial USB Hub 4
6AV2181-8XA80-0AX0
For contents and matching devices,
see Technical Data in the Mall
For contents and matching devices,
see Technical Data
Service set for Mobile Panel
277(F) IWLAN
Service set for 6" devices, Type 2
For contents and matching devices,
see Technical Data in the Mall
For contents and matching devices,
see Technical Data
Service set for Mobile Panel
6AV6574-1AA00-4AX0
For contents and matching devices,
see Technical Data in the Mall
For contents and matching devices,
see Technical Data
Service set for 15" devices
Order No.
Service set for 6" devices, Type 1
6AV6671-4XA00-0AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for Mobile Panel
277(F) IWLAN V1
6AV6671-5CA00-0AX1
For contents and matching devices,
see Technical Data in the Mall
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Siemens ST 80 / ST PC · 2013
2/121
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective covers
■ Overview
Protective covers with IP65 degree of protection provide
complete frontal protection of the panel against dirt and
scratches; the protective covers can be kept clean using highpressure cleaning equipment. Ready-made templates can be
downloaded to help you create and print out your own low-cost
frame designs between panel and protective cover.
2
Adhesive protective membranes are available for simple display
protection.
Protective covers are available for the following
SIMATIC HMI Panels:
• Touch Panels
• Operator Panels
• Multi Panels
■ Technical specifications
6AV6574-1AE004AX0
6AV6671-1AJ000AX0
6AV6671-2DJ000AX0
6AV6671-3CK010AX0
6AV6671-3CK000AX0
Protective cover 6"
Touch devices
Protective cover
OP77
Protective cover
OP177
Protective cover
MP 277 8" Touch
Protective cover
MP 277 10" Touch
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Degree and class of protection
IP (at the front)
IP65
IP65
IP65
IP65
IP65
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
Relative humidity
• max. relative humidity
95 %
95 %
95 %
95 %
95 %
Mechanics/material
Plastic
Yes
Yes
Yes
Yes
Yes
Dimensions
Width
242.3 mm
178.6 mm
274.3 mm
270.8 mm
355.8 mm
Height
186.3 mm
214.6 mm
243.26 mm
211 mm
294 mm
Thickness
10 mm
7.8 mm
7.8 mm
7.8 mm
7.8 mm
Height of housing front
• Mounting cutout, width
• Mounting cutout, height
198 mm
142 mm
135 mm
171 mm
229 mm
196 mm
226 mm
166 mm
310 mm
248 mm
Weight
Weight without packaging
750 g
750 g
750 g
750 g
750 g
Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible
2/122
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective covers
■ Technical specifications (continued)
Scope of supply
Number of sets
other
Note:
■ Ordering data
Protective covers
for 6" Touch devices
6AV6574-1AE004AX0
6AV6671-1AJ000AX0
6AV6671-2DJ000AX0
6AV6671-3CK010AX0
6AV6671-3CK000AX0
Protective cover 6"
Touch devices
Protective cover
OP77
Protective cover
OP177
Protective cover
MP 277 8" Touch
Protective cover
MP 277 10" Touch
2; 2 cover frames,
2 base frames,
2 protective covers,
molded (for TP 070,
TP 170micro,
TP 170A/B), 2 protective covers, smooth
(for TP 177micro,
TP 177A/B, TP 270 6",
MP 177 6" Touch,
MP 270 6" Touch)
2; 2 cover frames,
2 base frames,
2 protective covers
2; 2 cover frames,
2 base frames,
2 protective covers
2; 2 cover frames,
2 base frames,
2 protective covers
2; 2 cover frames,
2 base frames,
2 protective covers
for TP 070,
TP 170A, TP 170B,
TP 170micro,
TP 177micro,
TP 177A, TP 177B,
TP 270 6 ", TP 277 6 ",
MP 270 6" Touch
for OP 77A, OP 77B
For OP177B
for MP 277 8" Touch
as far as product
version "ES 14" with
narrow frame
for MP 277 10" Touch
up to product version
"ES 14 ", Thin Client
10" up to "ES 03"
(6AV6646-0AA212AX0) with narrow
frame
Order No.
6AV6574-1AE00-4AX0
This catalog only includes accessories for current products.
For TP 070, TP 170micro,
TP 177micro, TP 170A/B,
TP 177A/B, TP 270 6", TP 277 6",
MP 177 6" Touch, MP 270 6" Touch
consisting of: see technical data
Protective covers for OP 77
Note:
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
6AV6671-1AJ00-0AX0
or on our SIMATIC Support pages:
http://support.automation.siemens.com
For OP77 and OP77B
consisting of: see technical data
Protective covers for OP 177
6AV6671-2DJ00-0AX0
For OP177B
consisting of: see technical data
Protective covers for MP 277 8"
Touch devices
6AV6671-3CK01-0AX0
Only suitable for MP 277 8" Touch
up to E14 1) (for devices with a
narrow frame geometry)
consisting of: see technical data
Protective covers for MP 277 10"
Touch devices
6AV6671-3CK00-0AX0
Only suitable for
MP 277 10" Touch up to E14 1)
and 10" Thin Client up to E03 2)
(for devices with a narrow frame
geometry)
consisting of: see technical data
1)
E14 = Product version 14
2)
E03 = Product version 03
Siemens ST 80 / ST PC · 2013
2/123
2
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
■ Overview
Protective films for:
• Touch Panels
• C7 devices
• Multi Panels
• Thin Clients
• Touch Panels
• Basic Panels
• Comfort Panels
• Mobile Panels
2
Protective films protect the display from dirt and scratching
during operation and use.
For complete protection of the front side in harsh environments,
protective covers are available for some devices.
Note:
During installation, the protective films must completely cover
the display. For compatibility reasons, not all protective films
extend as far as the edge of the enclosure. This does not,
however, affect the protective function.
2/124
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
■ Technical specifications
6AV6671-2EC000AX0
6AV6671-2XC000AX0
6AV6574-1AD044AA0
6AV6671-5BC000AX0
6AV6645-7AB150AS0
6AV6671-3DC000AX0
Protective film
4" Touch
devices
Protective film
6" Touch
devices, Type 3
Protective film
6" Touch
devices,
Type 10
Protective film
8" Touch
devices,
Type 10
Protective film
10" Touch
devices,
Type 10
Protective film
10" Thin Client
and MP277 up to
ES14
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
90 %
90 %
90 %
Films
printable with laser printer
Yes
Yes
Yes
Yes
Yes
Yes
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes; Nonreflecting
Yes;
Nonreflecting
Dimensions
Width
120 mm
179.4 mm
120.5 mm
155.5 mm
223.17 mm
292 mm
Height
105 mm
141.4 mm
91 mm
124.9 mm
170.37 mm
248 mm
Thickness
0.125 mm
0.125 mm
0.125 mm
0.3 mm
0.3 mm
0.125 mm
Scope of supply
Delivery unit in items
10
10
10
2
10
10
for TP 177B 4",
KTP 400 Basic
for TP 177micro,
TP 177A,
TP 177B,
OP 177B,
KTP 600 Basic
for
Mobile Panel 170,
Mobile Panel 177
for
Mobile Panel 277
8"
for
Mobile Panel 277
10"
Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format possible
Mechanics/material
Plastic
other
Note:
Siemens ST 80 / ST PC · 2013
2
2/125
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
■ Technical specifications (continued)
2
6AV6671-3DC000AX5
6AV6574-1AD004EX0
6AV2124-6DJ000AX0
6AV2124-6GJ000AX0
6AV2124-6JJ000AX0
6AV2124-6MJ000AX0
Protective film
10" Key Panel,
Thin Client and
MP277 as of
ES15
Protective film
15" TP1500,
MP370/377 and
ThinClient
Protective film
4" widescreen
Protective film
7" widescreen
Protective film
9" widescreen
Protective film
12" widescreen
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
90 %
90 %
90 %
Films
printable with laser printer
Yes
Yes
Yes
Yes
Yes
Yes
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Dimensions
Width
299.8 mm
362 mm
131.4 mm
205.4 mm
265.4 mm
321.4 mm
Height
259.9 mm
289 mm
107.4 mm
149.4 mm
181.4 mm
232.4 mm
Thickness
0.125 mm
0.125 mm
0.125 mm
0.125 mm
0.125 mm
0.125 mm
Scope of supply
Delivery unit in items
10
10
10
10
10
10
for KTP400
Comfort, KTP400
Basic color PN
for TP700
Comfort,
IPC277D
for TP900
Comfort,
IPC277D
for TP1200
Comfort,
IPC277D
Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible
Mechanics/material
Plastic
other
Note:
2/126
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
■ Technical specifications (continued)
6AV2124-6QJ00-0AX1
6AV2124-6UJ00-0AX1
6AV2124-6XJ00-0AX1
Protective film 15" widescreen
Protective film 19" widescreen
Protective film 22" widescreen
Yes
Yes
Yes
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
Films
printable with laser printer
Yes
Yes
Yes
Mechanics/material
Plastic
Yes; Nonreflecting
Yes; Nonreflecting
Yes; Nonreflecting
Dimensions
Width
368 mm
451 mm
518 mm
Height
231 mm
285 mm
334 mm
Thickness
0.125 mm
0.125 mm
0.125 mm
Weight
Weight without packaging
26 g; Per unit
34 g; Per unit
44 g; Per unit
Scope of supply
Delivery unit in items
10
10
10
for Comfort Panel, IPC, Flat Panel,
Thin Client
for Comfort Panel, IPC, Flat Panel,
Thin Client
for Comfort Panel, IPC, Flat Panel,
Thin Client
Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible
other
Note:
Siemens ST 80 / ST PC · 2013
2
2/127
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
■ Technical specifications (continued)
2
6AV6574-1AD004DX0
6AV6574-1AD004CX0
6AV6671-2XC000AX0
6AV6671-3CC000AX0
6AV6671-3CC000AX5
6AV7672-1CE000AA0
Protective film
6" Touch
devices, Type 2
Protective film
10" - 12" TP/MP
270/370/377 and
C7-636
Protective film
6" Touch
devices, Type 3
Protective film
8" Touch
devices, Type 1
Protective film
8" Touch
devices, Type 2
Protective film
19" MP377,
panel PC and
Flat Panel
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
90 %
90 %
90 %
Films
printable with laser printer
Yes
Yes
Yes
Yes
Yes
Yes
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Yes;
Nonreflecting
Dimensions
Width
178.4 mm
297.4 mm
179.4 mm
207 mm
217 mm
378 mm
Height
135.4 mm
254.4 mm
141.4 mm
165 mm
217 mm
302.5 mm
Thickness
0.125 mm
0.125 mm
0.125 mm
0.125 mm
0.125 mm
0.2 mm
Scope of supply
Delivery unit in items
10
10
10
10
10
10
for TP 177micro,
TP 177A,
TP 177B,
OP 177B,
KTP 600 Basic
for MP 277 8"
Touch up to
product version
"ES 14"
for MP 277 8"
Touch in product
version "ES 15"
and later
Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible
Mechanics/material
Plastic
other
Note:
2/128
for TP 270 6",
TP 277 6",
MP 177 6" Touch,
MP 270B 6"
Touch
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
■ Ordering data
Protective films for 4" Touch
devices
Order No.
Protective films for 6" Touch
devices, type 1
For contents and matching devices,
see Technical Data and Mall
6AV6574-1AD00-4AX0
6AV6671-2XC00-0AX0
Protective films for 6" Touch
devices, type 4
For contents and matching devices,
see Technical Data and Mall
6AV3672-2CS00
Protective films for 10" Touch
devices, type 3
6AV3672-2CS11
For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 4
For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 10
6AV6574-1AD04-4AA0
6AV6671-5BC00-0AX0
6AV6645-7AB15-0AS0
6AV6671-3DC00-0AX0
6AV6671-3DC00-0AX5
6AV6574-1AD00-4EX0
6AV2124-6DJ00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films 7" widescreen
Protective films for 6" Touch
devices, type 3
6AV6671-2XC00-0AX0
Protective films for 8" Touch
devices, type 1
6AV6671-3CC00-0AX0
Protective films for 8" Touch
devices, type 2
6AV6671-3CC00-0AX5
For contents and matching devices,
see Technical Data and Mall
For contents and matching devices,
see Technical Data and Mall
Protective films 4" widescreen
6AV6574-1AD00-4CX0
For contents and matching devices,
see Technical Data and Mall
For contents and matching devices,
see Technical Data and Mall
Protective films for 15" Touch
devices
Protective films for 10" to 12"
Touch devices
For contents and matching devices,
see Technical Data and Mall
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 2
6AV6574-1AD00-4DX0
For contents and matching devices,
see Technical Data and Mall
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 1
Protective films for 10" Touch
devices, type 2
For contents and matching devices,
see Technical Data and Mall
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 10
2
For contents and matching devices,
see Technical Data and Mall
For contents and matching devices,
see Technical Data and Mall
Protective films for 8" Touch
devices, type 10
Order No.
6AV6671-2EC00-0AX0
Protective films for 19" Touch
devices
6AV7672-1CE00-0AA0
For contents and matching devices,
see Technical Data and Mall
6AV2124-6GJ00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films 9" widescreen
6AV2124-6JJ00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films 12" widescreen
6AV2124-6MJ00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films 15" widescreen
6AV2124-6QJ00-0AX1
For contents and matching devices,
see Technical Data and Mall
Protective films 19" widescreen
6AV2124-6UJ00-0AX1
For contents and matching devices,
see Technical Data and Mall
Protective films 22" widescreen
6AV2124-6XJ00-0AX1
For contents and matching devices,
see Technical Data and Mall
Note:
This catalog only includes accessories for current products. The
complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Siemens ST 80 / ST PC · 2013
2/129
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
■ Overview
All parts required to install a SIMATIC HMI Panel are listed here.
Mounting frames enable compliance with device-specific
degrees of protection IP65, NEMA4x and NEMA12 (indoor only)
if the thickness of the mounting plate is less than the minimum
plate thickness specified in the operating instructions. The
mounting frame has been specially developed for plate thicknesses of less than 2 mm.
2
Depending on the device, different mounting clips are available
for attaching the panel.
Memory card locks (snappable and slideable) are also available
to secure memory cards in the SIMATIC HMI Comfort Panels.
• Push Button Panel
• Key Panel
• Text Display
• Operator Panel
• Touch Panel
• Multi Panel
• Basic Panel
• Comfort Panel
Note regarding Industrial USB Hub 4:
The mounting frame is only available in the service pack
6AV6671-3EA01-0AX0.
■ Technical specifications
6AV6671-3CS00-0AX0
6AV6671-3CS01-0AX0
6AV6671-8XS00-0AX0
Mounting frame 8" Touch
Mounting frame 8" Key
Mounting frame 10" to 12"
Touch devices
Installation type/mounting
Mounting in portrait format possible
Yes
Yes
Yes
Mounting in landscape format possible
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
Mechanics/material
Type of housing (front)
• Sheet steel
Yes
Yes
Yes
Scope of supply
Delivery unit in items
1
1
1
other
Note:
For MP 277 8" Touch
For MP 277 8" Key
For KTP1000 Basic, MP 277 10"
Touch, MP 377 12" Touch,
Thin Client 10"
2/130
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
■ Technical specifications (continued)
6AV6671-8XK00-0AX2
6AV6671-8XK00-0AX1
6AV6671-8XK00-0AX0
Mounting clip, plastic
Mounting clip, spring
Mounting clip, aluminum
Installation type/mounting
Mounting in portrait format possible
Yes
Yes
Yes
Mounting in landscape format possible
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
Mechanics/material
Screw type
• 4.5 V
Yes; Original partially Phillips screw
Type of housing (front)
• Plastic
• Aluminum
Yes
2
Yes
Yes
Yes
Dimensions
Width
30 mm
20 mm
15 mm
Height
17 mm; Without screw
35 mm
21 mm; Without screw
Thickness
8 mm
20 mm
15 mm
Weight
Weight without packaging
4 g; Per unit
8 g; Per unit
5 g; Per unit
Scope of supply
Delivery unit in items
20
20
20
TD17, OP7/17/73, OP77A/B,
TP/OP170, KP300 mono,
KTP400 color, TP/OP177 except
TP177 4", MP270-6T, TP/OP270-6"
TP177-4", TP/OP 277-6", MP177-6,
MP277-10" T, MP277-8", MP277-8"T,
MP277-10"K, MP377 12-19", TC 10",
TC 15", KTP400 Basic mono,
KTP600, KTP1000, KTP1500,
KP700 Comfort, TP700 Comfort,
KP900 Comfort, TP900 Comfort,
KP1200 Comfort, TP1200 Comfort
and IPC 277D 7, 9, 12"
TP177-4", TP/OP 277-6", MP177-6,
MP277-10" T, MP277-8", MP277-8"T,
MP277-10"K, MP377 12-19", TC 10",
TC 15", KTP400 Basic mono,
KTP600, KTP1000, KTP1500,
KP700 Comfort, TP700 Comfort,
KP900 Comfort, TP900 Comfort,
KP1200 Comfort, TP1200 Comfort
and IPC 277D 7, 9, 12"
other
Note:
Siemens ST 80 / ST PC · 2013
2/131
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
■ Technical specifications (continued)
2
6AV6671-8XK00-0AX3
6AV6671-8XK00-0AX4
Mounting clip, steel
Mounting bracket, steel
Installation type/mounting
Mounting in portrait format possible
Yes
Yes
Mounting in landscape format possible
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
90 %
90 %
Mechanics/material
Screw type
• 4.5 V
Yes
Yes
Type of housing (front)
• Sheet steel
Yes
Yes
Dimensions
Width
20 mm
142 mm
Height
15 mm; Without screw
18 mm; Without screw
Thickness
8 mm
8 mm
Scope of supply
Delivery unit in items
20
10
15", 19" and 22" widescreen - Comfort Panels, IPCs, Flat
Panels and Thin Clients. Plate thicknesses up to 6 mm
15", 19" and 22" widescreen - Comfort Panels, IPCs, Flat
Panels and Thin Clients, except SCD1900 19" widescreen. Plate thicknesses up to 6 mm
other
Note:
2/132
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
■ Technical specifications (continued)
6AV2181-4DM10-0AX0
6AV2181-4XM00-0AX0
Memory card lock 4"
Memory card lock 7" - 22"
Installation type/mounting
Wall mounting/direct mounting possible
Yes; Snap-on
Yes; Snap-on
Degree and class of protection
IP (at the front)
20
20
Standards, approvals, certificates
CE
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
90 %
90 %
Mechanics/material
Plastic
Yes
Yes
Dimensions
Width
25 mm
45 mm
Height
30 mm
59 mm
Thickness
10 mm
12 mm
Weight
Weight without packaging
4 g; Per unit
6 g; Per unit
Scope of supply
Delivery unit in items
5
5
other
Note:
Comfort Panel 4"
Comfort Panels 7" to 22"
2
Siemens ST 80 / ST PC · 2013
2/133
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
■ Ordering data
Mounting frame 8" Touch
Order No.
6AV6671-3CS00-0AX0
For contents and matching devices,
see Technical Data and Mall
Mounting frame for 8" Key
2
4" memory card lock
6AV6671-3CS01-0AX0
For contents and matching devices,
see Technical Data and Mall
Mounting frame 10"/12" Touch
Order No.
Mounts and interlocks
7" … 22" memory card lock
6AV6671-8XS00-0AX0
6AV2181-4DM10-0AX0
For contents and matching devices,
see Technical Data and Mall
6AV2181-4XM00-0AX0
For contents and matching devices,
see Technical Data and Mall
For contents and matching devices,
see Technical Data and Mall
Mounting clip/bracket
Plastic mounting clip
6AV6671-8XK00-0AX2
For contents and matching devices,
see Technical Data and Mall
Spring mounting clip
6AV6671-8XK00-0AX1
For contents and matching devices,
see Technical Data and Mall
Aluminum mounting clip
6AV6671-8XK00-0AX0
For contents and matching devices,
see Technical Data and Mall
Steel mounting clip
6AV6671-8XK00-0AX3
For contents and matching devices,
see Technical Data and Mall
Steel mounting bracket
6AV6671-8XK00-0AX4
For contents and matching devices,
see Technical Data and Mall
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
2/134
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Labeling strips
■ Overview
Labeling strips and membranes are available for:
• Text display
• Multi Panel
• Mobile Panel
The labeling strips, blank membranes, and protective
membranes should be printed at a printing works.
Templates can be used to create labeling strips for SIMATIC HMI
devices. Alternatively, a tool for the creation of labeling strips is
available.
Download templates from:
http://support.automation.siemens.com/WW/view/en/11274631
and
download Label Creator from:
http://support.automation.siemens.com/WW/view/en/61507590
Labeling strips
Protective cover for labeling strips for Mobile Panel 170,
Mobile Panel 177
■ Technical specifications
6AV6574-1AB044AA0
6AV6671-5BF000AX0
6AV6574-1AB002BA0
6ES7272-1BF007AA0
6ES7272-1AF007AA0
6AV6671-0AP000AX0
Protective
sleeve labeling
strips
Labeling set
Mobile
Panel 277
Labeling strip
MP 37x Key
Front membrane TD100C,
blank
Front membrane TD200C,
blank
Front membrane TD400C,
blank
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
50 °C
0 °C
Storage/transport temperature
• Min.
• max.
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
-20 °C
60 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
90 %
90 %
90 %
Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format possible
Siemens ST 80 / ST PC · 2013
2/135
2
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Labeling strips
■ Technical specifications (continued)
2
6AV6574-1AB044AA0
6AV6671-5BF000AX0
6AV6574-1AB002BA0
6ES7272-1BF007AA0
6ES7272-1AF007AA0
6AV6671-0AP000AX0
Protective
sleeve labeling
strips
Labeling set
Mobile
Panel 277
Labeling strip
MP 37x Key
Front membrane TD100C,
blank
Front membrane TD200C,
blank
Front membrane TD400C,
blank
Films
Number of films per sheet
6
3
2
Yes
Yes
Yes
Yes
Yes
Dimensions
Width
210 mm
210 mm
210 mm
210 mm
210 mm
Height
297 mm
297 mm
297 mm
297 mm
297 mm
printable with laser printer
6
No
Width of the housing front
163 mm
Height of housing front
91 mm
Scope of supply
Delivery unit in items
5
Number of sets
other
Note:
for Mobile Panel
170, Mobile Panel
177
■ Ordering data
Protective cover
for Mobile Panel 17x
2
1
10
10
10
6
2
60
30
20
For Mobile Panel
277
For MP 370 Key,
MP 377 Key
For TD100C
For TD200C
For TD400C
Order No.
6AV6574-1AB04-4AA0
This catalog only includes accessories for current products.
For contents and matching devices,
see Technical Data in the Mall
Labeling set for Mobile Panel 277
6AV6671-5BF00-0AX0
6AV6574-1AB00-2BA0
For contents and matching devices,
see Technical Data in the Mall
Front membrane TD100C,
unprinted
6ES7272-1BF00-7AA0
For contents and matching devices,
see Technical Data in the Mall
Front membrane TD200C,
unprinted
6ES7272-1AF00-7AA0
For contents and matching devices,
see Technical Data in the Mall
Front membrane TD400C,
unprinted
6AV6671-0AP00-0AX0
For contents and matching devices,
see Technical Data in the Mall
2/136
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
For contents and matching devices,
see Technical Data in the Mall
Labeling set for MP 377 Key
Note:
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Batteries
■ Overview
2
Rechargeable buffer battery for Mobile Panel
Lithium battery for SIMATIC HMI, C7 and S7
■ Technical specifications
W790 84-E1001-B2
6ES7 623-1AE01-5AA0
6AV6 671-5CL00-0AX0
6AV6 671-5AD00-0AX0
Lithium battery
SIMATIC HMI and C7
Lithium battery
SIMATIC HMI, C7 and S7
Main battery Mobile Panel
IWLAN
Rechargeable back-up
battery Mobile Panel
Installation type/mounting
Wall mounting/direct mounting possible
Yes; in HMI devices,
battery compartment
Yes; in HMI devices,
battery compartment
Yes; in HMI devices,
battery compartment
Yes; in HMI devices,
battery compartment
Supply voltage
Type of supply voltage
DC
DC
DC
DC
Rated voltage/DC
3.6 V; 1.6 Ah
3.6 V; 1.6 Ah
7.2 V; 5.1 Ah
3.6 V; 1.15 Ah
Battery
Design
• Special design
Yes; 2/3 AA
Yes; 2/3 AA
Yes; bent
Yes; flat
Technology
• Lithium-ion
Yes; SL-361
Yes; SL-361
Yes; 2ICR19/65-2 CGR
Yes; 1/CP7/34/50 01 CGA
Standards, approvals, certificates
CE
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C; Don't charge below
55 °C
0 °C; Don't charge below
Storage/transport temperature
• Min.
• max.
-20 °C
70 °C
-55 °C
85 °C
-20 °C
70 °C
-20 °C
70 °C
Relative humidity
• max. relative humidity
90 %
90 %
90 %
90 %
75 mm
35 mm
Height
33 mm; Length
33 mm; Length
78 mm
50 mm
Thickness
14.7 mm; Diameter
14.7 mm; Diameter
33 mm
10 mm
Weight
Weight without packaging
12 g
14 g
320 g
38 g
1; incl. 220 mm connecting
cable
1; Incl. 45 mm + 210 mm
connecting cable
1
1; incl. 65 mm connecting
cable
for TD17, OP17, OP25,
OP27, OP35, OP37, TP27,
TP37, OP/TP270, MP 270,
MP 270B, MP 370, C7-621,
C7-623, C7-624, C7-626
and PG 7xx
for TD17, OP17, OP25,
OP27, OP35, OP37, TP27,
TP37, OP/TP270, MP 270,
MP 270B, MP 370, C7-621,
C7-623, C7-624, C7-626
and PG 7xx
for Mobile Panel 277
IWLAN, Mobile Panel 277F
IWLAN, Mobile Panel 277
IWLAN V2, Mobile Panel
277F IWLAN V2, Mobile
Panel 277F IWLAN (RFID
tag)
for Mobile Panel DP cabled,
Mobile Panel PN cabled,
Mobile Panel 277 IWLAN,
Mobile Panel 277F IWLAN
Dimensions
Width
Scope of supply
Delivery unit in items
other
Note:
Siemens ST 80 / ST PC · 2013
2/137
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Batteries
■ Ordering data
Lithium battery for SIMATIC HMI
and C7
Order No.
W79084-E1001-B2
This catalog only includes accessories for current products.
For contents and matching devices,
see Technical Data
Lithium battery for
SIMATIC PG7xx, HMI and C7
2
6ES7623-1AE01-5AA0
6AV6671-5CL00-0AX0
For contents and matching devices,
see Technical Data
Rechargeable buffer battery for
Mobile Panel
6AV6671-5AD00-0AX0
For contents and matching devices,
see Technical Data
2/138
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
incl. 250 mm adapter cable
Main rechargeable battery for
Mobile Panel IWLAN
Note:
Siemens ST 80 / ST PC · 2013
3
© Siemens AG 2013
HMI devices
for special requirements
3/2
Introduction
3/3
3/4
3/7
3/12
3/14
3/16
3/16
3/17
3/19
3/20
Fully enclosed HMI devices
SIMATIC MP 377 PRO
SIMATIC HMI IPC477C PRO
SIMATIC Flat Panel PRO
SIMATIC Thin Client PRO
Accessories
for fully enclosed HMI devices
Adapter sets
Extension units
IP65 keyboards
USB interfaces
3/21
3/22
Devices with stainless steel front
SIMATIC HMI IPC677C INOX
3/25
3/26
3/30
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
SIMATIC HMI Thin Client Ex
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI devices for special requirements
Introduction
■ Overview
Fully enclosed HMI devices
The fully enclosed SIMATIC HMI devices (MP 377 PRO,
HMI IPC477C PRO, Flat Panel PRO and Thin Client PRO) are
specially designed for mounting on a support arm/stand. Thanks
to their extremely rugged design, the devices are ideal for industrial applications in harsh environments.
Devices with stainless steel front
For special requirements, the HMI IPC677C INOX with stainless
steel front for use in the food and beverages industry.
HMI devices for hazardous areas
3
The SIMATIC HMI Ex devices (HMI Panel PC Ex and HMI Thin
Client Ex) are intrinsically safe Panel PCs and Thin Clients that
have been specially developed for hazardous areas "Zone 1"
and "Zone 2". Further SIMATIC HMI devices are also available for
the hazardous area "Zone 2" and can be found in the chapter
"Operator panels".
3/2
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
Overview
■ Overview
The SIMATIC HMI PRO devices can be mounted direct on the
support arm head of the desired support arm system using the
basic adapter supplied. The adapter set can be ordered
separately. The basic adapter can be attached to the top or
bottom of the device. The connecting cables are run through the
support arm.
With the extension units, the range of possible on-site operations
can be expanded. The extension units can be mounted on the
right and/or left side of the SIMATIC HMI PRO device and can be
equipped individually with, for example, illuminated
pushbuttons, emergency stop buttons, RFID readers, etc.
The SIMATIC HMI PRO (PRO = protected) devices have been
designed for mounting on a support arm/pedestal. Thanks to
their rugged aluminum enclosures, the SIMATIC HMI PRO
devices offer overall IP65 protection and are also suitable for use
in harsh environments. The separation of HMI and control
cabinet allows flexible design concepts.
The SIMATIC HMI PRO devices are used wherever the HMI
device cannot be installed direct in the control cabinet due to
restricted space, or whenever an operator control unit is
required direct at the machine. All the devices are fan-free,
and only standard connecting cables are used.
The following are available as SIMATIC fully enclosed
HMI devices:
• SIMATIC MP 377 PRO 15" Touch:
Multi Panel for operator control and monitoring of machines
and plants
• SIMATIC HMI IPC477C PRO 15"/19" Touch:
Compact, high-performance and maintenance-free
embedded IPC
• SIMATIC Flat Panel PRO 15"/19" Touch:
Industrial monitor with touch functionality, can be located up
to 30 m from the operator control unit
(as with Flat Panel Extended)
• SIMATIC Thin Client PRO 15" Touch:
HMI device for terminal and web client applications
Siemens ST 80 / ST PC · 2013
3/3
3
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO
■ Overview
■ Technical specifications
MP 377 PRO 15"
15" (304.1 mm x 228.1 mm)
Display type
TFT, 65536 colors
Resolution (pixels)
• Resolution (WxH in pixel)
1024 x 768
Backlighting
• MTBF backlighting (at 25 °C)
about 50000 hours
Control elements
Control elements
Touch screen
Connection for mouse/keyboard/
barcode reader
3
SIMATIC MP 377 PRO 15"
Analog, resistive
Supply voltage
Supply voltage
24 V DC
Input current
Rated current
1.8 A
Memory
Type
Flash / RAM
Time of day
Clock
• Type
Interfaces
Interfaces
Siemens ST 80 / ST PC · 2013
USB / USB / USB
Touch operation
• Touch screen
Usable memory for user data
3/4
6AV6 644-2AB01-2AX0
Display
Size
12288 KB usable memory for user
data / 12288 KB additional memory
for options
Hardware clock, battery backup,
synchronizable
1 x RS422, 1 x RS485,
2 x Ethernet (RJ45)
USB port
2 x USB
CF card slot
1 x CF card slot
Multi Media Card slot
1 x Multi Media Card slot
Industrial Ethernet
• Industrial Ethernet interface
2 x Ethernet (RJ45)
Protocols
Protocols (terminal link)
• [email protected]
Yes
Degree and class of protection
Front
IP65, NEMA 4, (when installed)
Rear
IP65
Standards, approvals, certificates
Certifications
CE, cULus, C-TICK, NEMA 4
FM Class I Div. 2
No
Suitable for safety functions
No
Use in hazardous areas
• EX zone 22
No
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO
■ Technical specifications (continued)
MP 377 PRO 15"
Ambient conditions
Mounting position
maximum permissible angle of
inclination without external ventilation
6AV6 644-2AB01-2AX0
vertical
+/- 45 °
MP 377 PRO 15"
6AV6 644-2AB01-2AX0
Functionality under
WinCC (TIA Portal) (continued)
Lists
• Number of text lists per project
• Number of graphics lists per project
500
500
Operating temperature
• Operation
0 °C to +45 °C
Storage/transport temperature
• Transport, storage
-20 °C to +60 °C
Relative humidity
• max. relative humidity
85 %
Archiving
• Number of archives per device
• Number of measuring points per
project
• Number of entries per archive
• external evaluation
Operating systems
Operating system
Windows CE
• Size of archive
WinCC flexible Standard Version
2008 or higher (to be ordered
separately)
Security
• Number of user groups
• Number of user rights
• Password export/import
50
32
Yes
Data carrier support
• CF card
Yes
Configuration
Configuration software
• Configuration tool
Languages
Online languages
• Number of online/runtime languages
5
Logging through printer
• Recording/Printing
Functionality under
WinCC (TIA Portal)
Libraries
Yes
Task planner
Yes
With alarm logging system
(incl. buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages
4 000
Yes
Yes
Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory
Variables
• Number of variables per device
Process coupling
• Connection to controller
• Limit values
• Multiplexing
Images
• Number of configurable images
500
Image objects
• Text objects
• Graphics object
30000 text elements
Bit maps, icons, vector graphics
50 000
Readable, e.g. with MS Excel,
MS Access, etc.
depending on free memory on ext.
card/stick or on free hard disk space
via network drive
Alarms, report (shift report), color
print, hardcopy
MPI/PROFIBUS DP, serial, USB,
Ethernet, by means of external
storage medium, automatic transfer
recognition
• S7-1200
• S7-1500
S5, S7-200, S7-300/400, TI 505,
Win AC, PC (TCP/IP), SINUMERIK,
SIMOTION, Allen Bradley (DF1),
Allen Bradley (DF485), Mitsubishi
(FX), OMRON (LINK/Multilink),
Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes
Expandability/openness
• Open Platform Program
Yes
I/O
I/O devices
• Multi Media Card
Printer, card reader, barcode reader
Yes
Dimensions
Front of enclosure (W x H)
400 mm x 310 mm
Weight
Weight
7.25 kg
500
1 000
1 000
128 KB integrated Flash,
expandable
4 096; Configuration with
WinCC flexible 2008 and higher
Yes
Yes
Complex image objects
• Status/control
• dynamic objects
Transfer (upload/download)
• Transfer of configuration
50
50
With SIMATIC S7
Diagrams, bar graphs, sliders,
analog display, invisible buttons
Siemens ST 80 / ST PC · 2013
3/5
3
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO
■ Ordering data
■ More information
Order No.
SIMATIC MP 377 PRO 15" Touch
Additional information is available on the Internet at:
6AV6644-2AB01-2AX0
15" color TFT display,
12 MB configuration memory,
can be configured from
WinCC Comfort (TIA Portal)
or from WinCC flexible 2008
http://www.siemens.com/ip65-hmi-devices
Note:
Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
3
310
400
SIMATIC MP 377 PRO 15" Touch
3/6
Siemens ST 80 / ST PC · 2013
G_ST80_XX_00351
67.85
98.5
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
■ Overview
3
SIMATIC HMI IPC477C PRO 19"
SIMATIC HMI IPC477C PRO 19" (rear view)
■ Technical specifications
HMI IPC477C PRO
6AV7 883-6….-…. 15"
6AV7 883-7….-…. 19"
Supply voltage
24 V DC
24 V DC
Processors
Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or
Core2 Duo 1.2 GHz
Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or
Core2 Duo 1.2 GHz
Memory type
DDR3-RAM
DDR3-RAM
Main memory
1 GB, 2 GB or 4 GB
1 GB, 2 GB or 4 GB
free slots
1 x CF card slot
1 x CF card slot
Operating system
Windows Embedded Standard 2009,
Windows Embedded Standard 7, Windows 7,
or Windows XP Professional Multi Language
Windows Embedded Standard 2009,
Windows Embedded Standard 7, Windows 7,
or Windows XP Professional Multi Language
Additional OS information
Language: EN/DE
Language: EN/DE
SIMATIC Software
Optionally with pre-installed bundle software
SIMATIC WinCC flexible 2008 or WinCC RT Advanced
and/or SIMATIC WinAC RTX / RTX F 2010,
SIMATIC WinCC or WinCC RT Professional as web client
or standard client
Optionally with pre-installed bundle software
SIMATIC WinCC flexible 2008 or WinCC RT Advanced
and/or SIMATIC WinAC RTX / RTX F 2010,
SIMATIC WinCC or WinCC RT Professional as web client
or standard client
Floppy drive
optional via external USB floppy drive
optional via external USB floppy drive
Optical drives
possible as an external drive via USB
possible as an external drive via USB
Hard disk/mass storage
CompactFlash drive with 4, 8, or 16 GB
and/or 50 GB SSD (High Endurance)
CompactFlash drive with 4, 8, or 16 GB
and/or 50 GB SSD (High Endurance)
General features
Drives
Siemens ST 80 / ST PC · 2013
3/7
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
■ Technical specifications (continued)
HMI IPC477C PRO
6AV7 883-6….-…. 15"
6AV7 883-7….-…. 19"
Graphics interface
DVI-I can be used for additional display unit
(only VGA via adapter); 32-bit color depth, graphics
memory up to 128 MB; resolution as for integrated
display in each case
DVI-I can be used for additional display unit
(only VGA via adapter); 32-bit color depth, graphics
memory up to 128 MB; resolution as for integrated
display in each case
Connection for keyboard/mouse
USB / USB
USB / USB
serial interface
COM1: 1 x V.24 (RS232)
COM1: 1 x V.24 (RS232)
PROFIBUS/MPI
Optionally onboard, isolated, max. 12 Mbit/s, no plug-in
card required, CP5611-compatible, not upgradable
Optionally onboard, isolated, max. 12 Mbit/s, no plug-in
card required, CP5611-compatible, not upgradable
PROFINET (RT/IRT)
Optional: 3 x RJ45, CP1616-compatible; not for retrofitting
Optional: 3 x RJ45, CP1616-compatible; not for retrofitting
USB
4 x on rear, USB 2.0 (500 mA)
4 x on rear, USB 2.0 (500 mA)
PROFINET (IE), Ethernet
onboard, 2 x 10/100/1000 Mbit (RJ45 without/with
PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFINET),
no plug-in card necessary
onboard, 2 x 10/100/1000 Mbit (RJ45 without/with
PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFINET),
no plug-in card necessary
Multimedia
No
No
Temperature
Yes
Yes
Watchdog
Yes
Yes
DiagBit (similar to S.M.A.R.T.)
Yes (for CF cards and SSD)
Yes (for CF cards and SSD)
Status LEDs
Yes
Yes
Front side according to EN 60529
IP65 all-round to EN 60529 and NEMA4
IP65 all-round to EN 60529 and NEMA4
Vibration load during operation
Tested according to DIN IEC 60068-2-6: 10 to 58 Hz:
0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g)
Tested according to DIN IEC 60068-2-6: 10 to 58 Hz:
0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g)
Shock loading during operation
Tested according to DIN IEC 60068-2-7:
50 m/s² (5 g), 30 ms, 100 shocks
Tested according to DIN IEC 60068-2-7:
50 m/s² (5 g), 30 ms, 100 shocks
Relative humidity
Tested according to DIN IEC 68-78, DIN IEC 60068-2-30:
5 % to 80 % at 25 °C (no condensation)
Tested according to DIN IEC 68-78, DIN IEC 60068-2-30:
5 % to 80 % at 25 °C (no condensation)
maximum permissible installation
angle +/-
+/- 45° from the vertical
+/- 45° from the vertical
Ambient temperature
0°C to 45 °C
0°C to 40°C
Approvals
CE, cULus(508)
CE, cULus(508)
EMC
CE, 55022A, EN 61000-6-4, EN 61000-6-2
CE, 55022A, EN 61000-6-4, EN 61000-6-2
Degree of protection
Overall device IP65/enclosure type 4x/type 12
(indoor use only)
Overall device IP65/enclosure type 4x/type 12
(indoor use only)
Dimensions
400 mm x 310 mm x 98 mm
483 mm x 400 mm x 115 mm
Weight
7.4 kg
10.9 kg
3/8
Siemens ST 80 / ST PC · 2013
Interfaces
3
Monitoring functions
Ambient conditions
Certifications & standards
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
■ Ordering data
Order No.
Order No.
IPC477C PRO as "Built to Order" versions
(max. delivery time is 15 working days and with identified repair).
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC flexible
6AV7883- 7 A 7 7 7 - 7 7 7 0
Embedded and fan-free, with IP65
housing with all-round protection;
5 x USB (500 mA),
1 of which on the front
24 V DC power supply
with On/Off switch
Front panels
• 15" TFT Touch (IP65 enclosure)
• 19" TFT Touch (IP65 enclosure)
Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE)
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE)
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
Main memory
(DDR3 RAM), 1 database
• 1 GB
• 2 GB
• 4 GB
Mass storage swappable
(formatted with a partition)
• None
• CompactFlash 2 GB
• CompactFlash 4 GB
• CompactFlash 8 GB
• CompactFlash 16 GB
• 50 GB SSD (High Endurance)
Mass storage
(with Windows Embedded Standard
2009 (EN/DE) / Windows Embedded
Standard 7 pre-installed and
optionally with SIMATIC software)
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009)
• CompactFlash 4 GB
• CompactFlash 8 GB
• CompactFlash 16 GB
• 50 GB SSD (High Endurance)
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC flexible (continued)
6AV7883- 7 A 7 7 7 - 7 7 7 0
Operating system
(pre-installed and activated)
• Windows Embedded Standard
2009
• Windows XP Professional
Multi-Language, only with SSD;
without SIMATIC software
• Windows Embedded Standard 7
SP1, pre-installed on internal drive,
CF > 4 GB, SSD, and 2 GB main
memory
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp) pre-installed on SSD
6
7
A
B
BA
DA
E A
GA
Software packages
WinAC / WinCC flexible
CF 4 GB or more and SSD,
only together with
Windows Embedded Standard 2009
or Windows Embedded Standard 7
• With WinAC RTX
pre-installed and configured
for PROFIBUS and with
WinCC flexible 2008 RT
(incl. Archives/Recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
D
E
F
G
H
J
• With WinAC RTX and WinCC flexible 2008 RT (incl. Archives/Recipes) pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
• With WinAC RTX F
pre-installed and configured for
PROFIBUS DP 12
- Number of tags 128 PT
1
2
3
0
2
3
4
5
6
• With WinAC RTX F and
WinCC flexible 2008 RT
(incl. Archives/Recipes),
pre-installed and configured
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
B
C
D
E
F
K
L
M
N
P
R
S
T
U
2
3
4
5
6
Siemens ST 80 / ST PC · 2013
3/9
3
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
■ Ordering data
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC RT Advanced
Order No.
6AV7883-
Order No.
7A777-777 1
Embedded and fan-free, with IP65
housing with all-round protection;
5 x USB (500 mA),
1 of which on the front
24 V DC power supply
with On/Off switch
Front panels
• 15" TFT Touch (IP65 enclosure)
• 19" TFT Touch (IP65 enclosure)
3
Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE)
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE)
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
Main memory
(DDR3 RAM),1 database
• 2 GB
• 4 GB
Mass storage, removable
• None
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009)
• CompactFlash 4 GB
• CompactFlash 8 GB
• CompactFlash 16 GB
• 50 GB SSD (High Endurance)
Mass storage, installed
(Windows Embedded Standard 7
pre-installed and optionally with
SIMATIC software)
• CompactFlash 4 GB
• CompactFlash 8 GB
• CompactFlash 16 GB
• 50 GB SSD (High Endurance)
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC RT Advanced
(continued)
Operating system
(pre-installed and activated)
• Windows Embedded Standard 7,
pre-installed on internal drive
6AV7883-
7A777-777 1
E A
Software packages
WinAC / WinCC RT Advanced
• With WinAC RTX
pre-installed and configured
for PROFIBUS and with
WinCC RT Advanced
(incl. Logging & Recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
6
7
A
B
D
• With WinAC RTX and
WinCC RT Advanced
(incl. Logging & Recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
• With WinAC RTX F
pre-installed and configured
for PROFIBUS DP 12
E
F
G
H
J
• With WinAC RTX F and WinCC RT
Advanced (incl. Logging & Recipes) pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
2
3
B
C
D
E
F
K
L
M
N
P
R
S
T
U
0
2
3
4
5
6
3
4
5
6
Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
For further bundles with SIMATIC HMI IPC477C PRO with
SIMATIC WinCC V7.0 and SIMATIC WinCC RT Professional
(TIA Portal), see under SIMATIC HMI IPC477C bundles
3/10
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
■ Dimensional drawings
400
348.7
All dimensions in mm. For installation cutout, see technical specifications.
SIMATIC HMI IPC477C PRO 15" Touch version
81.85
78.85
119
482.7
G_ST80_XX_00401
400
G_ST80_XX_00400
105
3
SIMATIC HMI IPC477C PRO 19" Touch version
■ More information
Additional information is available on the Internet at:
Note:
http://www.siemens.com/ip65-hmi-devices
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
Siemens ST 80 / ST PC · 2013
3/11
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Flat Panel PRO
■ Overview
3
SIMATIC Flat Panel Monitor PRO 19"
SIMATIC Flat Panel Monitor PRO 15" with expansion unit (rear view)
■ Technical specifications
Flat Panel
PRO 15"
PRO 19"
Supply voltage
Flat Panel
PRO 15"
PRO 19"
Certification
cULus (UL 508),
NEMA4-tested
cULus (UL 508),
NEMA4-tested
EMC
CE EN 55011
class A
CE EN 55011
class A
Certifications & standards
Supply voltage
24 V DC and
230 V AC
combined
24 V DC and
230 V AC
combined
permissible frequency range
47 to 63 Hz
47 to 63 Hz
Power consumption, max.
35 VA
35 VA
Standards, approvals, certificates
CE mark
Yes
Yes
up to 30 m
up to 30 m
UL approval
Yes
Yes
General features
Can be separate from the computer
Display
Ambient conditions
On-screen display (OSD)
configuration
Yes
Yes
Display version
15" TFT
19" TFT
visible area (H x W) in mm
304 x 228
376 x 301
Viewing angle
140° x 120°
(min)
140° x 120°
(min)
Pixel pitch
0.297 mm x
0.297 mm
0.297 mm x
0.297 mm
Inclination angle
Resolution (W x H in pixels)
1024 x 768
1280 x 1024
Interfaces
Refresh rate
60 to 75 Hz
60 to 75 Hz
Line frequency
46.7 - 80 kHz
46.7 - 80 kHz
Brightness/contrast
> 260 cd/m2 /
350:1
> 300 cd/m2 /
300:1
Number of colors
16.7 million
16.7 million
MTBF of backlit display (at 25 °C,
24 hours continuous operation)
50,000 h
50,000 h
1 g (10 m/s²)
1 g (10 m/s²)
5 g (50 m/s²)
5 g (50 m/s²)
Temperature
• Ambient temperature during operation
5 to +45 °C
5 to +45 °C
+/- 45° from the
vertical
+/- 45° from the
vertical
Graphics interface
Standard VGA
interface 15-pin
sub-D/digital
DVI-D interface
Standard VGA
interface 15-pin
sub-D/digital
DVI-D interface
Interface for Touch
USB (V1.1)
USB (V1.1)
USB interface for touch screen
Yes
Yes
400 mm x 310
mm x 91 mm
483 mm x 400
mm x 105 mm
6.7 kg
10 kg
Mounting
Dimensions
External dimensions (W x H x D)
Type of operation
Touch screen
analog-resistive
analog-resistive
Connection for keyboard/mouse/
barcode reader
Yes, via USB
Yes, via USB
Degree of protection
Overall device
IP65/enclosure
type 4x/type 12
(indoor use only)
Overall device
IP65/enclosure
type 4x/type 12
(indoor use only)
3/12
Vibration load during operation
Shock loading during operation
Siemens ST 80 / ST PC · 2013
Weight
Weight
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Flat Panel PRO
■ Ordering data
■ More information
Order No.
SIMATIC Flat Panel PRO 15"
Touch
6AV7861-5TB10-1BA0
SIMATIC Flat Panel PRO 19"
Touch
6AV7861-6TB10-1BA0
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
400
310
3
67.85
G_ST80_XX_00350
90.85
SIMATIC Flat Panel PRO 15" Touch
483
400
SIMATIC FLAT PANEL
G_ST80_XX_00371
82
105
SIMATIC Flat Panel PRO 19" Touch
Siemens ST 80 / ST PC · 2013
3/13
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Thin Client PRO
■ Overview
■ Technical specifications
Thin Client PRO 15" Touch
15.1"
Display type
TFT, 65536 colors
Resolution (pixels)
• Resolution (WxH in pixel)
1024 x 768
Backlighting
• MTBF backlighting (at 25 °C)
about 50000 hours
Control elements
Control elements
Touch screen
Connection for mouse/keyboard/
barcode reader
3
SIMATIC Thin Client PRO 15"
Analog, resistive
Supply voltage
Supply voltage
24 V DC
Processor
Processor
ARM, 266 MHz
Memory
Type
Flash / RAM
Usable memory for user data
No info
Interfaces
Interfaces
1 x Ethernet (RJ45)
USB port
1 x USB
Industrial Ethernet
• Industrial Ethernet interface
1 x Ethernet (RJ45)
Protocols
WEB characteristics
• HTTP
• HTML
• CSS
Yes
Yes
Yes
Protocols (terminal link)
• [email protected]
• RDP
Yes
Yes
Degree and class of protection
Front
Rear
Standards, approvals, certificates
Certifications
Siemens ST 80 / ST PC · 2013
USB / USB
Touch operation
• Touch screen
EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A)
3/14
6AV6646-2AB21-2AX0
Display
Size
Yes; EN 61000-6-4, interference
emission: Intended for use in
industrial areas.
IP65, NEMA 4x, NEMA 12
(when installed)
IP65
CE, cULus, C-TICK,
NEMA 4x (Enclosure Type 4X,
Type 12), NEMA 12
EMC
The product is designed for use in
industrial environments. When used
in residential areas, the emission of
radio interference according to limit
class B of EN 55011 must be
ensured. For further information
please refer to the user documentation.
Suitable for safety functions
No
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Thin Client PRO
■ Technical specifications (continued)
400
0 °C to +45 °C
Storage/transport temperature
• Transport, storage
-20 °C to +60 °C
Relative humidity
• max. relative humidity
85 %; (Storage)
Dimensions
Front of enclosure (W x H)
400 mm x 310 mm
Weight
Weight
6.5 kg
SIMATIC Thin Client PRO 15"
Touch
All dimensions in mm. For installation cutout, see technical
specifications.
+/- 45 °
Operating temperature
• Operation
■ Ordering data
■ Dimensional drawings
3
Order No.
6AV6646-2AB21-2AX0
90.85
SIMATIC Thin Client with
[email protected]
• Touch device 15" PRO with
[email protected] license (panels)
• Touch device 15" PRO with
[email protected] license for
WinCC flexible 2008 Runtime
67.85
Starter packages
6AV6653-6CA01-2AA0
6AV6653-6FA01-2AA0
Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
G_ST80_XX_00350
Ambient conditions
maximum permissible angle of
inclination without external ventilation
6AV6646-2AB21-2AX0
310
Thin Client PRO 15" Touch
SIMATIC Thin Client PRO 15" Touch
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
Siemens ST 80 / ST PC · 2013
3/15
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
Adapter sets
■ Overview
■ More information
Adapter sets
• The adapter sets are required for connecting the
SIMATIC HMI PRO device with the support arm head of the
respective support arm system
• By directly connecting the support arm head to the device,
there is complete flexibility in the choice of support arm
components
• Adapter sets are available for the VESA 75 and
VESA 100 systems.
• Further adapter sets can be obtained directly from the
respective supporting bracket manufacturer: Bernstein, Rittal,
Rose and Haseke
3
■ Ordering data
Order No.
VESA 100 adapter set 1) for
• VESA 100
• Rose GTN II
6AV7674-0KD00-0AA0
Adapter set VESA 75 for
• VESA 75
6AV7674-0KE00-0AA0
Replacement basic adapter,
suitable for
SIMATIC HMI PRO devices
6AV7674-0KA00-0AA0
1)
The VESA 100 adapter set cannot be used in combination
with the 19" Flat Panel PRO.
Note:
The internal diameter of the 48 mm supporting bracket tubes is
not suitable for passage of the standard DVI-D cable.
Scope of delivery:
• One basic adapter or one adapter plate
• Mounting hardware
3/16
Siemens ST 80 / ST PC · 2013
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
Extension units
■ Overview
■ Ordering data
Order No.
Extension Unit 15"
6AV7674-0KG00-0AA0
For mounting on all 15" PRO devices
Extension units
With the extension units, the range of possible on-site operations
can be extended. They are mounted on the SIMATIC HMI PRO
device and can be equipped individually, e.g. with Key Panel
(KP8), 3SB elements, emergency stop buttons, key switches,
RFID reader, etc.
• They can be mounted on the left or right side of the
PRO device, as required
• Direct installation of up to 2 Key Panels KP8 / KP8F
• IP65 - cable routing
• Can be equipped individually
• For all 15"/19" PRO devices
The combination of HMI PRO device and KP8 PN offers the
following advantages:
• No control cabinet required
• Low cabling overhead
• Optimally coordinated design
Extension Unit 15" KP8
For mounting on all 15" PRO devices
for direct installation of up to
2 KP8 / KP8F
6AV7674-0KG01-0AA0
Starter package Extension Unit
15" with KP8
1 x Extension Unit 15" KP8,
1 x Key Panel 8 PN,
1 x blank front
6AV7674-0KG11-0AA0
Extension Unit 19" right
• For support arm mounting
from above
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the left side of the 19" PRO device
6AV7674-0KJ00-0AA0
Extension Unit 19" KP8 right
• For support arm mounting
from above
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For direct installation of
up to 2 KP8 / KP8F
6AV7674-0KJ01-0AA0
Starter package Extension Unit
19" with KP8 right
1 x Extension Unit 19" KP8 right,
1 x Key Panel 8 PN,
1 x blank front
6AV7674-0KJ11-0AA0
Extension Unit 19" left
• For support arm mounting
from above
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the right side of the 19" PRO device
6AV7674-0KH00-0AA0
Starter package Extension Unit
19" with KP8 left
1 x Extension Unit 19" KP8 left,
1 x Key Panel 8 PN,
1 x blank front
6AV7674-0KH11-0AA0
Extension Unit 19" KP8 left
• For support arm mounting
from above
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For direct installation of up to
2 KP8 / KP8F
6AV7674-0KH01-0AA0
3
Siemens ST 80 / ST PC · 2013
3/17
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
Extension units
■ Ordering data
3
Order No.
KP8 front plate
for the Extension Unit
• For installing up to two KP8
in an Extension Unit
• Suitable for all 15" and 19"
Extension Units
6AV7674-0KH30-0AB0
Empty front KP8 design
in combination
with front panel KP8
6AV3688-3XY38-3AX0
Spare front plate
for the Extension Unit
• Suitable for all 15" and 19"
Extension Units
• Required if the front plate supplied
with the Extension Unit must be replaced
6AV7674-0KH30-0AA0
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Scope of delivery:
• 1 Extension Unit box
• 1 front plate for the Extension Unit
• 1 connecting tube
• Mounting accessories
3/18
■ More information
Siemens ST 80 / ST PC · 2013
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
IP65 keyboards
■ Overview
■ More information
IP65 keyboards
Additional information is available on the Internet at:
With the stainless steel IP65 keyboards, the range of possible
on-site operations can be extended. They are mounted on the
SIMATIC HMI PRO device underneath the base adapter, and
they are available in two versions.
• Anti-twist and non-removable stainless steel key caps
• Abrasion-resistant laser labeling
(depth engraving with annealing marking)
• Secure, pleasant key feel
• Maximum user-friendliness thanks to withdrawable
long-stroke key
• Windows layout (EN/US) with two additional keys
(left and right mouse key function) via cursor block
• USB interface
• Angle-adjustable connection for optimal ergonomics
• Water and dust protection in accordance with degree of
protection IP65
• For all 15"/19" PRO devices
http://www.siemens.com/ip65-hmi-devices
■ Ordering data
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
3
Order No.
Stainless steel IP65 keyboard 15"
• Width: 400 mm (adapted to
15" SIMATIC HMI PRO)
• Windows layout (EN/US)
without NUM block
• Angle-adjustable adapter
6AV7674-0NC00-0AA0
Stainless steel IP65 keyboard 19"
• Width: 483 mm (adapted to
19" SIMATIC HMI PRO)
• Windows layout (EN/US)
with NUM block
• Angle-adjustable adapter
6AV7674-0NE00-0AA0
Tool and keyboard tray
• Width: 483 mm (adapted to
19" SIMATIC HMI PRO)
• Including 2-port USB interface
• Angle-adjustable adapter
6AV7674-0NE01-0AA0
Scope of delivery:
• One stainless steel IP65 keyboard incl. mounting adapter for
PRO devices
• Mounting accessories
Siemens ST 80 / ST PC · 2013
3/19
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
USB interfaces
■ Overview
■ More information
• The USB interface is used for connecting external peripheral
devices to the MP 377 PRO, the HMI IPC477C PRO,
the Flat Panels PRO, and the Thin Client PRO.
• USB peripheral devices can thus be connected and operated
without opening the device
• Extension of the internal USB interface externally
■ Ordering data
1-port USB interface
Order No.
6AV7674-0LX00-0AA0
For fully enclosed HMI devices,
length USB cable: 0.5 m
2-port USB interface
3
6AV7674-0LX01-0AA0
For fully enclosed HMI devices,
length USB cable: 0.5 m.
Not suitable for: Thin Client,
MP 377, and Flat Panel
3/20
Siemens ST 80 / ST PC · 2013
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
© Siemens AG 2013
HMI devices for special requirements
Devices with stainless steel front
Devices with stainless steel front
■ Overview
For special requirements, the following HMI devices with
stainless steel front (DIN EN 1672-2), e.g. for use in the food,
beverages and tobacco industries, are offered.
SIMATIC HMI IPC677C INOX
PC platform with high degree of industrial compatibility for
demanding tasks in the area of PC-based automation.
Note:
Do you require a specific modification to or option for the
products described here? Then look up "Customized products",
where you will find information about additional generallyavailable industry-specific products that can be ordered, as well
as about options for customer-specific modifications and
adaptations.
Rugged construction:
The PC is resistant to the harshest mechanical stress and is
reliable in operation.
• Compact design
• High degree of investment protection
• Fast integration capability
• 15" TFT Touch, stainless steel/INOX
• All interfaces such as PROFIBUS or PROFINET onboard
3
More SIMATIC HMI INOX panels
You will find further INOX industry products, as well as customerspecific product variants, in the "Customized Automation"
section, e.g.
• SIMATIC HMI Flat Panel 15" Touch INOX
• SIMATIC HMI Flat Panel 19" Touch INOX
• SIMATIC HMI Flat Panel 19" Touch INOX fully enclosed
Siemens ST 80 / ST PC · 2013
3/21
© Siemens AG 2013
HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX
■ Overview
■ Technical specifications
HMI IPC677C INOX 15" Touch
6AV789...
General features
Front panel
15" TFT Touch
Display
Screen diagonal
15"
Resolution (W x H in pixels)
1024 x 768
MTBF of backlighting (at 25 °C)
50 000 h at 24 h continuous operation, temperature-dependent
Type of operation
Touch screen
Yes
Design
Central design
Yes
Dimensions
3
PC platform with high degree of industrial compatibility for
demanding tasks in the area of PC-based automation.
Rugged design:
The PC is resistant to the harshest mechanical stress and is
reliable in operation.
• Compact design
• High degree of investment protection
• Fast integration capability
• Front panel versions:
- 15" TFT Touch, stainless steel/INOX
3/22
Siemens ST 80 / ST PC · 2013
Installation cutout/device depth
(W x H x D) in mm
450 x 290 x 142 (incl. optical drive)
Mounting dimensions in centralized
configuration (W x H x D, without
optical drive) in mm
450 x 290 x 121
Additional mounting depth
(optical drive) in mm
21
Weight
HMI IPC in a centralized configuration
approx.
14 kg
© Siemens AG 2013
HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX
■ Ordering data
SIMATIC HMI IPC677C INOX
Front panels
• 15" TFT Touch
Front options
• INOX front, without front USB,
with 15" TFT Touch only
Power supply
• 24 V DC
• 110/230 V AC,
power cable for Europe
• 110/230 V AC, without power cable
• 110/230 V AC, power cable for UK
• 110/230 V AC, power cable for CH
• 110/230 V AC,
power cable for the USA
• 110/230 V AC,
power cable for Italy
• 110/230 V AC,
power cable for China
Processor
• Intel Celeron 1.86 GHz
(2 MB shared cache), 2 cores
• Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFIBUS MPI,
2 MB buffered SRAM
• Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFINET
(3x RJ45, CP1616-compatible),
2 MB buffered SRAM
• Intel Core i3, 2.13 GHz
(3 MB shared cache),
2 cores, hyper-threading
• Intel Core i3, 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFIBUS MPI,
2 MB buffered SRAM
• Intel Core i3, 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFINET
(3x RJ45, CP1616-compatible),
2 MB buffered SRAM
• Intel Core i7, 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost
• Intel Core i7, 2.53 GHz
(4 MB shared cache),
2 cores, hyper-threading,
turbo boost, PROFIBUS MPI,
2 MB buffered SRAM
• Intel Core i7, 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost,
PROFINET (3 x RJ45,
CP 1616-compatible),
2 MB buffered SRAM
Order No.
Order No.
6AV789 7 - 7 7 7 7 7 - 7 7 7 7
6AV789 7 - 7 7 7 7 7 - 7 7 7 7
SIMATIC HMI IPC677C INOX
(continued)
Main memory
• 1 GB DDR3
• 2 GB DDR3
• 3 GB DDR3
• 4 GB DDR3
• 8 GB DDR3
• 2 GB DDR3 with ECC
• 4 GB DDR3 with ECC
• 8 GB DDR3 with ECC
2
2
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
J
0
1
2
3
4
5
6
7
Mass storage
• 250 GB SATA hard disk
• 500 GB SATA hard disk
• RAID1 dual hard disk module
2 x 250 GB SATA, preconfigured
• Dual hard disk module
2 x 250 GB SATA
• 50 GB SSD (SLC)
• Second CF card slot
(only in combination with
Windows XP embedded),
internal, empty, only with version
without opt. drive and without HDD
• Without mass storage
Optical drives
• None
• DVD±RW±R combo drive
0
1
2
3
3
4
5
8
0
1
Communication Interfaces
• 2 x PCI available
• 1 x PCI, 1 x PCIe (x16) available
A
B
Operating system
(pre-installed and activated)
• Without operating system
• Windows XP Professional
Multi-Language 1)
• Windows 7 Ultimate 32-bit
Multi-Language 1)
• Windows Embedded Standard
on 8 GB CF card 2)
• Windows 7 Ultimate 64-Bit
Multi-Language 1)
A
B
C
D
E
Software expansion
• None
• SIMATIC IPC DiagMonitor V4.3
enclosed
• SIMATIC IPC Image & Partition
Creator V3.2 enclosed
• SIMATIC IPC DiagMonitor V4.3,
Image & Partition Creator V3.2
enclosed
0
1
2
3
1)
Multi-language means: D/E/F/I/SP/CHIN traditional/CHIN simplified/
Korean/Japanese
2)
Without RAID 1 option only
Siemens ST 80 / ST PC · 2013
3/23
© Siemens AG 2013
HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX
■ Ordering data
Order No.
Non-heating apparatus cable for
SIMATIC Box and Panel PC
SIMATIC PC power cable,
230 V AC, angled, 3 m, for:
• Germany
• United Kingdom
• Switzerland
• USA
• Italy
• China
6ES7900-1AA00-0XA0
6ES7900-1BA00-0XA0
6ES7900-1CA00-0XA0
6ES7900-1DA00-0XA0
6ES7900-1EA00-0XA0
6ES7900-1FA00-0XA0
Touch pen
Captive pen for operation of the
touch devices, mounting of the
support on the control cabinet
6AV7672-1JB00-0AA0
Expansion components
From page 5/153
Communication components
From page 5/186
M
H
6ES7648-2AJ40-0KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-1KA0
G
Memory expansion
• 1 GB DDR3 DIMM
• 2 GB DDR3 DIMM
• 4 GB DDR3 DIMM
• 1 GB DDR3 DIMM with ECC
• 2 GB DDR3 DIMM with ECC
• 4 GB DDR3 DIMM with ECC
J
K
K
G_ST80_XX_00288
3
■ Dimensional drawings
All dimensions in mm.
Accessories
L
N
Panel PC 677C INOX 15" Touch
Control units
PC 677 INOX
G
H
J
K
L
M
N
289
271
138
11
24
367
42
Touch devices
15"
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/inox-hmi-devices
Note:
Do you require a specific modification or supplement to the
products described here? Then refer to "Customized products",
where you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
3/24
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
HMI devices for hazardous areas
■ Overview
The SIMATIC HMI Ex devices are intrinsically-safe Panel PCs
and Thin Clients which have been specially developed for
hazardous areas. The intrinsically-safe design allows simple
installation on site. The variety of certification allows use in many
parts of the world without further approvals.
Available as HMI devices for hazardous areas "Zone 1" and
"Zone 2" are:
• SIMATIC HMI Panel PC Ex
• SIMATIC HMI Thin Client Ex
The devices are fanless and permit completely maintenancefree installation without batteries or rotating parts.
Further SIMATIC HMI devices are also available for the
hazardous area "Zone 2/22" and can be found in the chapter
"Operator panels":
• SIMATIC HMI Comfort Panels
3
Siemens ST 80 / ST PC · 2013
3/25
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
■ Overview
SIMATIC HMI Panel PC Ex with international approvals for
operation and monitoring in hazardous areas.
3
■ Technical specifications
HMI Panel PC Ex
6AV7200-1...
HMI Panel PC Ex
Design
Panel PC built-in unit, protective
enclosure available as an option
Front
15" and 19", optional 15"
sunlight-readable displays
Operation
Touch with 8 function keys
Processor
Intel Atom N270 with 1.6 GHz
Main memory
1 GB DDR2 SDRAM, 2 GB optional
Operating system,
preinstalled and configured
Windows XP Professional,
Windows XP Embedded,
Windows 7 MUI
Mass storage
CompactFlash 4 GB / 16 GB,
hard disk 100 GB
Power supply
24 V DC, max. 2.1 A (19")
Devices in version "Zone 1"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
IECEx
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
Interfaces
Ethernet
10/100 Mbit Ex e, or fiber-optics
100 Mbit (SC) Ex op is
GOST-R
• Network 10/100 Base-Tx
USB 2.0
2 x Ex i, 2 x Ex e (Zone 1) or
2 x Ex nA (Zone 2)
• Network 10/100 Base-Fx
Serial
1 x RS232 or 1 x RS422/485
Ambient conditions
Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
2 Ex d e ia ib mb [iaib] IIC T4
DIP A21 TA80°C, IP66
2 Ex d e ia ib mb [iaibopis] IIC T4
DIP A21 TA80°C, IP66
Ex d e ia ib mb [ia ib] IIC T4 Gb,
Type 4X, IP66
Class II, Division 1, Groups E, F, G,
T80°C
Ex ia tb [ia ib] IIIC T80°C Db, IP66
Ex d e ia ib mb [ia ib] IIC T4
Ex ia tb [ia ib] IIIC T80°C Db IP66
IP66 at front, IP65 at rear,
IP66 in protective enclosure
Ambient temperature during operation
-20 °C ... +50 °C (cold start -10 °C)
with optional additional heating
down to -30 °C
KGS
Relative humidity during operation
90 % at + 40 °C, no condensation
InMetro
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
Device version "UL Class 1,
Division 2"
Siemens ST 80 / ST PC · 2013
II 2 (2) G Ex d e ia ib mb [ia ib] IIC
T4 Gb
II 2 (2) D Ex ia tb [ia ib] IIIC T80°C
Db IP66
II 2 (2) G Ex d e ia ib mb [ia ib op is]
IIC T4 Gb
II 2 (2) D Ex ia tb [ia ib op is] IIIC
T80°C Db IP66
CSA
Degree of protection
3/26
6AV7200-1...
Approvals/directives
General features
Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
Class 1, Division 2,
Groups A, B, C, D
Class 2, Division 2, Groups F, G
Class 3, Hazardous Locations
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
■ Technical specifications (continued)
HMI Panel PC Ex
6AV7200-1...
Devices in version "Zone 2"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
IECEx
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
GOST-R
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
CSA
InMetro
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
Device version "UL Class 1,
Division 2"
HMI Panel PC Ex
6AV7200-1...
Dimensions
II 3 (2/3) G Ex d e ia ib mb nA
[ib Gb] [ic] IIC T4 Gc
II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC
T80°C Dc IP66
II 3 (2/3) G Ex d e ia ib mb nA
[ib op is Gb] [ic] IIC T4 Gc
II 3 (2/3) D Ex ia tc [ib op is Db]
[ic] IIIC T80°C Dc IP66
Mounting dimensions (W x H x D)
15":
427.5 mm x 327.5 mm x 165 mm
19":
522.5 mm x 412.5 mm x 165 mm
Front dimensions (W x H)
15": 440 mm x 340 mm
19": 535 mm x 425 mm
Weight
15": 15 kg
19": 23 kg
Ex d e ia ib mb nA [ib Gb] [ic]
IIC T4 Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
Ex d e ia ib mb nA [ib op is Gb
] [ic] IIC T4 Gc
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
3
2 Ex d e ia ib mb nA [ib][ic] IIC T4
DIP A21 TA80°C, IP66
2 Ex d e ia ib mb nA [ib opis][ic] IIC
T4
DIP A21 TA80°C, IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc, Type 4X, IP66
Class II, Division 2, Groups E, F, G,
T80°C;
Ex ia tc [ib ic] IIIC T80°C Dc, IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
Ex d e ia ib mb nA [ib op is Gb] IIC
T4
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
Class 1, Division 2,
Groups A, B, C, D
Class 2, Division 2, Groups F, G
Class 3, Hazardous Locations
Siemens ST 80 / ST PC · 2013
3/27
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
■ Ordering data
SIMATIC HMI Panel PC Ex
3
Order No.
Order No.
6AV7200- 1 7 7 7 7 - 7 7 A 0
Design / display size
• Zone 2: 15" Touch
with function keys
• Zone 2: 19" Touch
with function keys
• Zone 1: 15" Touch
with function keys
• Zone 1: 19" Touch
with function keys
• UL Class 1, Division 2:
15" Touch with function keys
• UL Class 1, Division 2:
19" Touch with function keys
• Zone 2: 15" Touch, sunlight
readable with 8 function keys
• Zone 1: 15" Touch, sunlight
readable with 8 function keys
Communication interfaces
• 10/100 base Tx, Ex e
• 100 base Fx FOC (SC), Ex op is
Mass storage
• CF 4 GB, 1 GB RAM
• CF 16 GB, 1 GB RAM
• HDD 100 GB, 1 GB RAM
• CF 4 GB, 2 GB RAM
• CF 16 GB, 2 GB RAM
• HDD 100 GB, 2 GB RAM
Operating system (preinstalled)
• Windows XP Embedded on CF
(language package 1) 1)
• Windows XP Professional MUI
(only on HDD)
• Windows 7 Ultimate (only on HDD)
Enclosure options
(device is delivered already fitted)
• without
• Stainless steel enclosure for:
- Wall mounting
- Stand (incl. coupling,
300° rotation possible)
- Suspension bracket (incl.
coupling, 300° rotation possible)
- Support arm (incl. coupling,
300° rotation possible)
- Swivel arm from above (incl.
coupling, 300° rotation possible)
A
B
D
E
1)
G
H
J
K
A
B
1
2
3
4
5
6
1
3
4
0
2
3
4
5
6
A
B
C
D
E
F
G
-z
-z
-z
-z
A
B
C
D
0
0
0
0
1
1
1
1
Package 1: upon initial startup, select the language from: English, German,
French, Italian, Spanish, Portuguese, Brazilian, Dutch, Danish, Swedish,
Norwegian, Finnish, Greek, Hungarian, Czech, Polish, Turkish, Russian,
Hebrew, Arabic, Chinese, Japanese, Korean, Thai
3/28
Siemens ST 80 / ST PC · 2013
Digital KVM for HMI Thin Client Ex
6AV7675-0EX00-0AA0
USB drive
• Intrinsically-safe, 8 GB
• Intrinsically-safe,
8 GB with recovery function
6AV7675-0FX00-0AA0
6AV7675-0FX10-0AA0
Ethernet switch
6AV7675-0PX00-0AA0
with FOC 4 x 100 Base Tx,
1 x 100 Base (MTRJ) Fx Ex op is
External keyboard for stainless steel
enclosure (incl. keyboard enclosure)
• without
• QWERTZ keyboard
• QWERTY keyboard
• AZERTY keyboard
• QWERTZ keyboard with trackball
• QWERTY keyboard with trackball
• AZERTY keyboard with trackball
Further options together with
stainless steel enclosure
• Breather glands
• Heating (requires breather glands)
• Handles
• Front USB (at bottom)
Accessories
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
■ Dimensional drawings
Legend:
i = Clamping frame
h = Mounting clamp (10 x)
j = Control cabinet or enclosure
All dimensions in mm. For mounting cut-out see technical specifications.
3
h
426
i
427.5+0.5
j
G_ST80_XX_00419
340
327.5+0.5
165
326
440
SIMATIC HMI Panel PC Ex 15"
h
521
522.5+0.5
i
j
G_ST80_XX_00420
412.5+0.5
165
411
425
535
SIMATIC HMI Panel PC Ex 19"
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-hmi-ex
Siemens ST 80 / ST PC · 2013
3/29
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex
■ Overview
HMI Thin Client Ex
IECEx
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
GOST-R
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
3
HMI Thin Client Ex
6AV7200-0...
Design
Thin Client built-in unit, available in
protective enclosure as an option
Front
15", 19", and 15" sunlight readable
display
Operation
Touch with 8 function keys
MTBF backlight
50 000 h
Operating system
Closed system on Windows XP
Embedded basis
Mass storage
Integrated
Power supply
24 V DC, max. 2.1 A (19")
KGS
Ex d e ia ib mb [ia ib] IIC T4
Ex ia tb [ia ib] IIIC T80°C Db IP66
• Network 10/100 Base-Fx
• Network 10/100 Base-Fx
IECEx
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
Ethernet
100 Mbit Ex e, or alternatively
fiber-optics 100 Mbit (SC) Ex op is
USB 2.0
2 x Ex i, 2 x Ex e (Zone 1) or
2 x Ex nA (Zone 2)
GOST-R
• Network 10/100 Base-Tx
Serial
1 x RS232 or 1 x RS422/485
• Network 10/100 Base-Fx
Degree of protection
IP66 at front, IP65 at rear, IP66 in
protective enclosure
CSA
Ambient temperature during operation
- 20 °C ... + 50 °C, cold start -10 °C,
with optional additional heating
down to -30 °C
Relative humidity during operation
90 % at 40 °C, no condensation
Ambient conditions
InMetro
• Network 10/100 Base-Tx
Devices in "Zone 1" version
ATEX directive 94/9/EC
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx
II 2 (2) G Ex d e ia ib mb [ia ib] IIC
T4 Gb
II 2 (2) D Ex ia tb [ia ib] IIIC T80°C
Db IP66
II 2 (2) G Ex d e ia ib mb [ia ib op is]
IIC T4 Gb
II 2 (2) D Ex ia tb [ia ib op is] IIIC
T80°C Db IP66
Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
Devices in version "Zone 2"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx
Interfaces
Approvals/directives
2 Ex d e ia ib mb [iaib] IIC T4
DIP A21 TA80°C, IP66
2 Ex d e ia ib mb [iaibopis] IIC T4
DIP A21 TA80°C, IP66
Ex d e ia ib mb [ia ib] IIC T4 Gb,
Type 4X, IP66
Class II, Division 1, Groups E, F, G,
T80°C
Ex ia tb [ia ib] IIIC T80°C Db, IP66
■ Technical specifications
General features
Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
CSA
InMetro
• Network 10/100 Base-Tx
SIMATIC HMI Thin Client Ex with international approvals for
operation and monitoring in hazardous areas.
6AV7200-0...
• Network 10/100 Base-Fx
II 3 (2/3) G Ex d e ia ib mb nA [ib
Gb] [ic] IIC T4 Gc
II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC
T80°C Dc IP66
II 3 (2/3) G Ex d e ia ib mb nA [ib op
is Gb] [ic] IIC T4 Gc
II 3 (2/3) D Ex ia tc [ib op is Db] [ic]
IIIC T80°C Dc IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
Ex d e ia ib mb nA [ib op is Gb] [ic]
IIC T4 Gc
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
2 Ex de i a ib mb nA [ib][ic] IIC T4
DIP A21 TA80°C, IP66
2 Ex de i a ib mb nA [ibopis][ic] IIC
T4
DIP A21 TA80°C, IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc, Type 4X, IP66
Class II, Division 2, Groups E, F, G,
T80°C; Ex ia tc [ib ic] IIIC
T80°C Dc, IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
Ex d e ia ib mb nA [ib op is Gb] IIC
T4
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
Protocols
RDP, RealVNC
Digital KVM switch
Input: DVI / VGA, PS/2 / USB,
output: RJ45 (IP network)
Dimensions
3/30
Siemens ST 80 / ST PC · 2013
Mounting dimensions
(W x H x D) in mm
15": 427.5 x 327.5 x 165
19": 522.5 x 412.5 x 165
Front dimensions in mm
15": 440 x 340
19": 535 x 425
Weight
15": 15 kg, 19": 23 kg
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex
■ Ordering data
SIMATIC HMI Thin Client Ex
Design / display size
• Zone 2: 15" Touch
with function keys
• Zone 2: 19" Touch
with function keys
• Zone 1: 15" Touch
with function keys
• Zone 1: 19" Touch
with function keys
• Zone 2: 15" Touch, sunlight
readable with function keys
• Zone 1: 15" Touch, sunlight
• readable with function keys
Communication interfaces
• 10/100 base Tx, Ex e
• 100 base Fx FOC (SC), Ex op is
Enclosure options
(device is delivered already fitted)
• without
• Stainless steel enclosure for:
- Wall mounting
- Stand (incl. coupling,
300° rotation possible)
- Suspension bracket (incl.
coupling, 300° rotation possible)
- Support arm (incl. coupling,
300° rotation possible)
- Swivel arm from above (incl.
coupling, 300° rotation possible)
Order No.
6AV7200-
Order No.
077 0 0-77A0
A
B
D
E
Digital KVM for HMI Thin Client Ex
6AV7675-0EX00-0AA0
USB drive
• Intrinsically-safe, 8 GB
• Intrinsically-safe,
8 GB with recovery function
6AV7675-0FX00-0AA0
6AV7675-0FX10-0AA0
Ethernet switch
6AV7675-0PX00-0AA0
With FOC 4 x 100 Base Tx,
1 x 100 Base (MTRJ) Fx Ex op is
G
H
A
B
3
0
2
3
4
5
6
External keyboard for enclosure
(incl. keyboard enclosure)
• without
• QWERTZ keyboard
• QWERTY keyboard
• AZERTY keyboard
• QWERTZ keyboard with trackball
• QWERTY keyboard with trackball
• AZERTY keyboard with trackball
Further options together with
stainless steel enclosure
• Breather glands
• Heating (requires breather glands)
• Handles
• Front USB (at bottom)
Accessories
A
B
C
D
E
F
G
-z
-z
-z
-z
A
B
C
D
0
0
0
0
1
1
1
1
Siemens ST 80 / ST PC · 2013
3/31
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex
■ Dimensional drawings
Legend:
i = Clamping frame
h = Mounting clamp (10 x)
j = Control cabinet or enclosure
All dimensions in mm. For mounting cut-out see technical specifications.
G_ST80_XX_00419
327.5+0.5
340
3
165
326
440
h
426
i
427.5+0.5
j
SIMATIC HMI Thin Client Ex 15"
15" touch front
Width in mm
Height in mm
Depth in mm
Operating unit
440
340
165
Installation cutout
427.5 ± 0.5
327.5 ± 0.5
-
G_ST80_XX_00420
412.5+0.5
165
411
425
535
h
521
i
522.5+0.5
j
SIMATIC HMI Thin Client Ex 19"
19" touch front
Width in mm
Height in mm
Depth in mm
Operating unit
535
425
165
Installation cutout
522 ± 0.5
412.5 ± 0.5
-
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-hmi-ex
3/32
Siemens ST 80 / ST PC · 2013
4
© Siemens AG 2013
HMI Software
4/2
Introduction
4/5
4/6
4/12
4/14
4/19
4/25
4/31
4/32
4/34
4/36
4/37
4/38
4/42
4/44
4/47
4/50
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal)
Engineering
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
WinCC Runtime Professional
WinCC Runtime Communication
SIMATIC WinCC (TIA Portal) options
WinCC Recipes
WinCC Logging
WinCC Audit
SIMATIC Logon
WinCC [email protected]
WinCC Server / WinCC Client
WinCC WebNavigator
WinCC DataMonitor
WinCC ControlDevelopment
4/51
4/52
4/56
Software for energy management
SIMATIC B.Data
SIMATIC powerrate
4/59
SIMATIC WinCC flexible
HMI system
SIMATIC WinCC flexible ES
SIMATIC WinCC flexible RT
SIMATIC WinCC flexible options
WinCC flexible /ChangeControl
WinCC flexible /Archives
WinCC flexible /Recipes
WinCC flexible /Audit
SIMATIC Logon for WinCC flexible
WinCC flexible /[email protected]
WinCC flexible /[email protected]
WinCC flexible /OPC server
WinCC flexible /ProAgent
4/60
4/64
4/71
4/72
4/73
4/74
4/75
4/76
4/78
4/82
4/85
4/87
4/88
4/89
4/107
4/108
4/110
4/111
4/112
4/115
4/116
4/117
4/118
4/120
4/122
4/124
4/126
4/127
4/129
4/130
4/131
4/132
4/133
4/134
4/138
4/139
SCADA system SIMATIC WinCC
SIMATIC WinCC
SIMATIC WinCC options
SIMATIC BATCH for WinCC
SIMATIC Information Server
SIMATIC Logon
SIMATIC Maintenance Station
SIMATIC Process Historian
WinCC/Calendar Scheduler
WinCC/Central Archive Server (CAS)
WinCC/ChangeControl & WinCC/Audit
WinCC/Connectivity Pack &
WinCC Connectivity Station
WinCC/DataMonitor
WinCC/DowntimeMonitor
WinCC/Event Notifier
WinCC/IndustrialDataBridge
WinCC/IndustrialX
WinCC/Open Development Kit (ODK)
WinCC/ProAgent
WinCC/Redundancy
WinCC/Server
WinCC/TeleControl
WinCC/User Archives
WinCC/Web Navigator
4/144
WinCC add-ons and
partner management
4/146
SCADA System
SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
Add-ons
4/155
4/161
SIMATIC ProAgent process
diagnostics software
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
Introduction
HMI software
■ Overview
Engineering
Software
WinCC Professional
WinCC Advanced
WinCC Comfort
WinCC Basic
Integrated runtime
module
Comfort Panels
Mobile Panels
x77 Panels and
Multi Panels
PC-based
single-user system,
e.g. SIMATIC IPC
PC-based multi-user system
Integrated runtime
module
WinCC Runtime
Advanced
WinCC Runtime Professional
SCADA functionality
G_ST80_XX_00461
Runtime Software
and target systems
Basic Panels
4
With the product families SIMATIC WinCC (TIA Portal),
SIMATIC WinCC flexible, SIMATIC WinCC and SIMATIC WinCC
Open Architecture, SIMATIC HMI offers visualization and configuration software for the entire HMI spectrum:
• SIMATIC WinCC (TIA Portal)
Creation of applications in the machine-level area and of
process visualization or SCADA systems
• SIMATIC WinCC flexible
Creation of applications in the machine-level area:
• SIMATIC WinCC
Creation of process visualization or SCADA systems
• SIMATIC WinCC Open Architecture
Creation of applications with a high demand for customerspecific adaptations, large and/or complex applications, as
well as projects that demand special system requirements
and functions.
SIMATIC WinCC (TIA Portal)
WinCC (TIA Portal) is based on the new central engineering
framework Totally Integrated Automation Portal (TIA Portal),
which provides users with an integrated, efficient and intuitive
solution to all automation tasks. SIMATIC WinCC (TIA Portal)
covers applications in the machine-level area and applications
in the process visualization or SCADA environment. WinCC
(TIA Portal) offers the uniform and scalable configuration tools
WinCC Basic, Comfort, Advanced and Professional for configuring the current SIMATIC HMI devices:
• SIMATIC Basic Panels
• SIMATIC Comfort Panels
• SIMATIC Mobile Panels
• SIMATIC Panels 77/177/277 series
• SIMATIC Multi Panels of the 177/277/377 series
• PC-based systems
- SIMATIC WinCC Runtime Advanced
- SIMATIC WinCC Runtime Professional
In addition, WinCC (TIA Portal) offers:
• Intuitive user interface with maximum degree of operator
friendliness
• Clear configuration of devices and network topologies
• Shared data management and uniform symbols via controller
and HMI
• Optimum interaction with the controller and HMI in a working
environment
• Powerful editors for efficient engineering
• Integrated mass data operations for efficient configuration
• System diagnostics as an integral component
• Comprehensive library concept
4/2
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
Introduction
HMI software
■ Overview (continued)
SIMATIC WinCC flexible
SIMATIC WinCC
Covers applications in the machine-level area. WinCC flexible
offers the integrated and scalable configuration tools
WinCC flexible Micro, Compact, Standard and Advanced for
configuring SIMATIC HMI devices:
• SIMATIC Basic Panels
• SIMATIC Mobile Panels
• SIMATIC Micro Panels
• SIMATIC Panels of the 70/170/270 series as well as C7-635
and C7-636
• SIMATIC Multi Panels of the 170/270/370 series
• PC-based systems
- SIMATIC WinCC flexible Runtime
• Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
• Expanded integration into STEP 7 and SIMOTION
• Optionally expandable with functions for version administration and logging changes (WinCC flexible /ChangeControl)
• Modular PC-based HMI solution for single-user systems
directly at the machine level
• Basic package for visualization, reporting and logging; can be
expanded by implementing option packages
• Flexible expansion possible with VB scripts and customized
ActiveX controls created with OPP (Open Platform Program)
The process visualization or SCADA system for visualizing and
operating processes, production flows, machines and plants in
all sectors – from the simple single-user station through to
distributed multi-user systems with redundant servers and
cross-location solutions with web clients. WinCC is the information hub for company-wide, vertical integration (process
visualization and platform for IT & business integration).
• For universal use thanks to solutions for all sectors, e.g.
conforming to FDA 21 CFR Part 11, and multiple languages for
worldwide use
• All HMI functions on-board with industry-standard functions
for signaling and acknowledging events, archiving of
messages and measured values, logging of all process and
configuration data, user administration and visualization
(WinCC basic software).
• Company-wide, flexible client/server structures with operator
stations on the Web, distributed servers and data integrity
thanks to redundancy
• Easy to integrate over standard interfaces such as
OPC (OLE for Process Control), WinCC OLE-DB,
VBA (Visual Basic for Applications), VB script, C-API (ODK)
• Integration platform in the company thanks to the Historian
functionality integrated into WinCC based on the Microsoft
SQL Server, standard and programming interfaces and tools
and clients for evaluation
• Modular expansion with options and add-ons as well as
individual functional expansions with VB Script, Visual Basic
for Applications, C-API (ODK) and integration of ActiveX
elements.
• Object-orientation supports efficient engineering and flexible
plant expansion
• For large, distributed systems with up to 2048 servers
• Scalable – from a small single-user system up to a networked,
redundant high-end system
• WinCC OA can be used on any platform and is available for
Windows, Linux and Solaris
• Hot-standby redundancy and disaster recovery system
assure maximum fail-safety and availability
• WinCC OA offers a platform for customer-specific solutions
• Extensive driver and interfacing options: S7, SINAUT, OPC,
OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and
many others.
• Flexible logging of data either in file-based value archive or in
a relational database (ORACLE)
• Modular expansion is possible using options and add-ons as
well as individual functional expansions by means of own
script language CONTROL, API(C++) and integration of
ActiveX elements
Siemens ST 80 / ST PC · 2013
4/3
4
© Siemens AG 2013
HMI Software
Introduction
HMI software
■ Overview (continued)
SIMATIC WinCC Open Architecture
The SCADA system SIMATIC WinCC Open Architecture
addresses applications with high demand for customer-specific
adaptations, large and/or complex applications, as well as
projects that demand special system requirements and
functions.
SIMATIC WinCC Open Architecture demonstrates its high
performance in networked and redundant high-end control
systems in particular. From the field level to the control station,
from the machine to the company headquarters – integrated,
high-performance communication is ensured. In every situation,
a high level of availability, reliable information, fast interaction
and user friendliness are guaranteed. Applications can also be
changed without interrupting the process. Profitability, efficiency
and safety are therefore always in equilibrium.
With its disaster recovery system and SIL3 certification, SIMATIC
WinCC Open Architecture demonstrates its reliability in a wide
range of critical applications.
4
4/4
Siemens ST 80 / ST PC · 2013
SIMATIC WinCC Open Architecture is open for independent inhouse developments, which means that ideas can be turned into
new applications quickly and easily.
• Object-orientation supports efficient engineering and flexible
plant expansion
• For large, distributed systems with up to 2048 servers
• Scalable – from a small single-user system up to a networked,
redundant high-end system
• WinCC OA can be used on any platform and is available for
Windows, Linux and Solaris
• Hot-standby redundancy and disaster recovery system
assure maximum fail-safety and availability
• WinCC OA offers a platform for customer-specific solutions
• Extensive driver and interfacing options: S7, SINAUT, OPC,
OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and
many others.
• Flexible logging of data either in file-based value archive or in
a relational database (ORACLE)
• Modular expansion is possible using options and add-ons as
well as individual functional expansions by means of own
script language CONTROL, API(C++) and integration of
ActiveX elements
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
HMI Software in the TIA Portal
■ Overview
SIMATIC WinCC (TIA Portal) engineering software
• Family of configuration systems with WinCC Basic, Comfort,
Advanced and Professional for SIMATIC operator panels, as
well as for the PC-based visualization systems WinCC
Runtime Advanced and WinCC Runtime Professional
SIMATIC WinCC Runtime Advanced visualization software
• PC-based HMI solution for single-user systems directly at the
machine
• Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts
• Basic package expandable by means of option packages
• Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment
• Can be integrated into automation solutions based on TCP/IP
networks
• Expanded service concepts with remote operation,
diagnostics and administration over the Intranet and Internet
in combination with e-mail communication
SIMATIC WinCC Runtime Professional visualization
software
• PC-based operator control and monitoring system for visualization and operator control of processes, production flows,
machines and plants in all sectors – from the simple singleuser station through to distributed multi-user systems and
cross-location solutions with web clients. WinCC Runtime
Professional is the information hub for corporation-wide
vertical integration.
• Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
• Basic package expandable by means of option packages
• Also included are APIs for the Runtime to utilize the open
programming interfaces
• Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment
4
Siemens ST 80 / ST PC · 2013
4/5
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
■ Overview
■ Application
• Integrated family of engineering tools for configuring
SIMATIC HMI operator panels, as well as for the PC-based
visualization systems WinCC Runtime Advanced and
WinCC Runtime Professional.
• WinCC (TIA Portal) is based on the new central engineering
framework Totally Integrated Automation Portal (TIA Portal),
which offers the user a uniform, efficient and intuitive solution
to all automation tasks.
• WinCC (TIA Portal) also offers uniform engineering from the
Basic Panel through to the SCADA application.
• Together with the STEP 7 (TIA Portal) products, WinCC
(TIA Portal) forms the optimum solution for integrated, efficient
engineering.
Current version:
• SIMATIC WinCC Basic V12 SP1
• SIMATIC WinCC Comfort V12 SP1
• SIMATIC WinCC Advanced V12 SP1
• SIMATIC WinCC Professional V12 SP1
■ Benefits
4
• The integrated configuration software reduces training,
maintenance and service overhead and protects the
customer's investments.
• Minimized engineering overhead and reduction of lifecycle
costs thanks to Totally Integrated Automation (TIA)
• Minimized configuration overhead due to reuse of scalable
and dynamizable objects
• Intelligent tools for efficient and simple configuration:
- Wizard for defining the basic structure of the HMI project
- Table-based editors simplify the generation and processing
of similar types of object, e.g. for tags, texts, or alarms.
- Complex configuration tasks such as the definition of paths
of motion or the creation of the fundamental operator
prompting are simplified by means of graphical configuration.
• Comprehensive support of multi-language configurations for
worldwide use
- Selectable views for entering configuration data in several
languages
- System and user-specific text lexicons
- Export/import of language-dependent texts
• Investment protection due to
- Import of the configuration from WinCC flexible 2008 SP2
and 2008 SP3
- Transfer of the configuration from WinCC V7.0 SP3
4/6
Siemens ST 80 / ST PC · 2013
SIMATIC WinCC in the editions Basic, Comfort, Advanced and
Professional are innovative engineering tools for configuring
SIMATIC HMI operator panels, as well as for the PC-based
visualization systems WinCC Runtime Advanced and WinCC
Runtime Professional.
Depending on the selected product, various target systems can
be configured:
WinCC Basic
• Basic Panels
WinCC Comfort
• As WinCC Basic, plus:
• Comfort Panels
• Mobile Panels: Mobile Panel 177, Mobile Panel 277
• Panels of the 70 series: OP 73, OP 77A, OP 77B
• Panels of the 170 series: TP 177A, TP 177B, OP 177B
• Panels of the 270 series: TP 277, OP 277
• Multi Panels: MP 177, MP 277, MP 377
WinCC Advanced
• As WinCC Comfort, plus:
• SIMATIC PCs with WinCC Runtime Advanced:
- SIMATIC Panel PC: IPC277D, Panel PC 477B, IPC477C,
IPC477D, Panel PC 577B, IPC577C, Panel PC 677B,
IPC677C
- SIMATIC Box PC: IPC227D, Box PC 427B, IPC427C,
IPC427D, Box PC 627B, IPC627C, Box PC 827B, IPC827C
- SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
- SIMATIC modular Embedded Controller: EC31
• Standard PC with WinCC Runtime Advanced
• SINUMERIK PC: PCU 50.3, PCU 50.5
WinCC Professional
• As WinCC Advanced, plus:
• SIMATIC PCs with WinCC Runtime Professional:
- SIMATIC Panel PC: IPC477C, IPC477D, Panel PC 577B,
IPC577C, Panel PC 677B, IPC677C,
- SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B,
IPC627C, IPC827C
- SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
• Standard PC with WinCC Runtime Professional
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
■ Design
The functionalities of the engineering tools of the SIMATIC
WinCC family are based on each other. The available editors are
largely determined by the respective configurable target
systems and their function. A more comprehensive engineering
tool such as WinCC Advanced can always be used to configure
lower-level target devices as well (e.g. Basic Panels)
A Powerpack can be used to upgrade from a smaller edition to
a larger one. This does not apply to WinCC Basic.
The functionality of WinCC engineering tools already contains
the configuration support of the available Runtime options for
SIMATIC Panels, WinCC Runtime Advanced or WinCC Runtime
Professional, irrespective of the purchased RT licenses.
A separate license is required for the target system when using
the configured Runtime options.
■ Function
Integration into automation systems
Integration into the SIMATIC Totally Integrated Automation Portal
(TIA Portal)
• Shared data management and uniform symbols via the
controller and HMI
• Optimum interaction between the controller and HMI in a
working environment
• System diagnostics as an integral component
• Shared use of communication settings and process point
definitions
• Simple dragging and dropping of tags from STEP 7 to an
HMI device, e.g. onto a screen
• Excellent support for the new SIMATIC S7-1500 controller
- With symbolic addressing
- Access to the new memory-optimized data blocks
- New alarm and diagnostics concept
Configuration interface
• Intuitive user interfaces with maximum degree of
user friendliness
• Comprehensive and fast access to editors and project data
• Adaptive user interface of engineering tools depending on
configured target system
• User-definable user interface settings, e.g. layout, toolbars
• Integrated mass data operations for efficient configuration
Project handling
• Device-independent configuration data can be used on a
variety of target systems without the need for conversion.
The interface adapts itself to the functional possibilities of the
target device.
• Cross-device utilization of common configuration data
(e.g. alarm classes, text library) in multi-device projects
• Wizard-assisted definition of basic structure of HMI projects
(e.g. display layout, operator prompting)
Screen editor with comprehensive options for efficient and
fast screen configuration
• Generation of interconnected screen objects via Drag&Drop,
e.g. tags for the creation of input/output fields with process
interfacing or buttons with screen selection function
• Definition of screen templates and functions
(comparable with the Slide Master in MS PowerPoint)
• User-friendly editor for the creation of faceplates with defined
external interface from screen objects
• Graphics-based configuration of motion paths
• Layer technology with up to 32 layers
• Tools for the Align, Rotate and Mirror functions
Import/export
• of tags, links, text lists, and alarms
Tabular editors
• Quick and easy generation and modification of configuration
objects of the same type, e.g. tags, texts or messages, in
tabular editors
• Intelligent default settings depending on previously
configured data, e.g. automatic incrementing of addresses
when generating consecutive tags
• Simple access to the properties of an object without superfluous user intervention
• Simultaneous modification of common object properties
Object-based data management with user-friendly search
and edit options
• Configuration of alarms and logs directly on the HMI tag,
no switching between different editors
• Cross-reference list with direct access to all objects,
e.g. for editing or selection
• Search for objects in entire project
• Text search and replace functions
Project documentation
• Selective project documentation, the following contents can
be printed:
- An entire project
- One or more project-associated devices
- Contents of an editor
- Libraries
Siemens ST 80 / ST PC · 2013
4/7
4
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
■ Function (continued)
Libraries for predefined/user-defined configuration objects
• Storage of all configuration objects in the library, e.g. blocks
and even entire screens or tags
• Faceplates can be constructed from simple screen objects on
a customer-specific or project-specific basis. Changes to
these faceplates can be made centrally (block definition).
• A large number of scalable and dynamizable screen objects
is included in the scope of delivery
• Size-scalable graphics for industrial applications are included
in the scope of delivery
• Preview function for library objects
System prerequisites
WinCC engineering software
Processor type (min.)
Core i5; 2.4 GHz or comparable
RAM (min.)
3 GB (32-bit operating system)
8 GB (64-bit operating system)
Free hard disk space
2 GB on system drive "C:"
Operating systems
32-bit operating systems
• Windows XP Home SP3
(only WinCC Basic)
• Windows XP Professional SP3
• Windows 7 Home Premium SP1
(only WinCC Basic)
• Windows 7 Professional SP1
• Windows 7 Enterprise SP1
• Windows 7 Ultimate SP1
• Windows Server 2003 R2 Standard
Edition SP2
(only WinCC Advanced
and Professional)
• Windows Server 2008 Standard
Edition SP2
(only WinCC Advanced
and Professional)
Language support
• Multilingual project creation (max. 32 languages) in editors
thanks to selectable views
• Central management of language-specific texts and graphics
in libraries
• Edit, export and import of texts for translation
• Language-specific graphics
4
Visual Basic and C-Script Support
• IntelliSense function for fast programming of access to
runtime objects
• Simple creation of control sequences in script code
• Visual Basic Script debugging in simulator and
WinCC Runtime Advanced and WinCC Runtime Professional
Test and commissioning support
• Simulation of HMI projects on engineering PC
• Marking of incomplete or incorrect configuration directly in the
respective editor
• Jump to error cause based on alarm messages in the
Compiler
Migration of existing HMI projects
• Data transfer in projects from WinCC flexible
• Data transfer in projects from WinCC
64-bit operating systems
• Windows 7 Home Premium SP1
(only WinCC Basic)
• Windows 7 Professional SP1
• Windows 7 Enterprise SP1
• Windows 7 Ultimate SP1
• Windows Server 2008 R2 Standard
Edition SP2
(only WinCC Advanced
and Professional)
Screen resolution
at least 1280 x 1024
Optical drive
DVD-ROM
Note:
Opening several instances of WinCC on your engineering PC at
the same time may result in more demanding hardware requirements.
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past: Size of swap
file = 3 x size of RAM.
For further information, refer to your Windows documentation
4/8
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
■ Ordering data
Order No.
WinCC Basic V12 SP1
Engineering software for the
configuration and simulation of
Basic Panels;
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation on
DVD, floating license, license key
on USB stick
• New type of delivery:
Online software delivery 1),
floating license, software
and license key download,
e-mail address required for the
delivery
6AV2100-0AA02-0AA5
6AV2100-0AA02-0AH5
WinCC Comfort V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation
on DVD, floating license,
license key on USB stick
• New type of delivery:
Online software delivery 1),
floating license, software
and license key download,
e-mail address required for the
delivery
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professional
(with max. 4096 PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation
on DVD, floating license,
license key on USB stick
• New type of delivery:
Online software delivery 1),
floating license, software
and license key download,
e-mail address required for the
delivery
6AV2103-0HA02-0AA5
6AV2103-0HA02-0AH5
WinCC Professional max.
PowerTags V12 SP1
6AV2101-0AA02-0AA5
6AV2101-0AA02-0AH5
WinCC Advanced V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Advanced,
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation on
DVD, floating license, license key
on USB stick
• New type of delivery:
Online software delivery 1),
floating license, software
and license key download,
e-mail address required for the
delivery
Order No.
WinCC Professional 4096
PowerTags V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professional
(unlimited PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation
on DVD, floating license,
license key on USB stick
• New type of delivery:
Online software delivery (OSD) 1),
floating license, software
and license key download,
e-mail address required for the
delivery
4
6AV2103-0XA02-0AA5
6AV2103-0XA02-0AH5
Trial licenses
6AV2102-0AA02-0AA5
6AV2102-0AA02-0AH5
on DVD, 21 day trial
• WinCC Basic V12 SP1
• WinCC Comfort/Advanced
V12 SP1
• WinCC Professional V12 SP1
6AV2100-0AA02-0AA7
6AV2102-0AA02-0AA7
6AV2103-0AA02-0AA7
WinCC Professional 512
PowerTags V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professiona
l (with max. 512 PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation on
DVD, floating license,
license key on USB stick
• New type of delivery:
Online software delivery 1),
floating license, license key
download,
e-mail address required for the
delivery
1)
6AV2103-0DA02-0AA5
6AV2103-0DA02-0AH5
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Siemens ST 80 / ST PC · 2013
4/9
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
■ Ordering data
Order No.
Software Update Service
SIMATIC WinCC Engineering
System Powerpacks
(without version change)
For a period of 12 months and for a
fixed price, the customer is automatically provided with all upgrades
and service packs for each installed
WinCC engineering system or
option.
Floating license, license key
only on USB stick
• WinCC Basic to
WinCC Comfort V12 2)
• WinCC Comfort to
WinCC Advanced V12
• WinCC Advanced to WinCC
Professional 512 PowerTags V12
• WinCC Professional Powerpack
512 PowerTags to
4096 PowerTags V12
• WinCC Professional Powerpack
4096 PowerTags to max.
PowerTags V12
6AV2101-2AA02-0AC5
6AV2102-2AA02-0BD5
6AV2103-2AD02-0AC5
6AV2103-2DH02-0BD5
6AV2103-2HX02-0BD5
Online software delivery (OSD) 1)
4
Order No.
Powerpacks
Floating license, license key
download only
e-mail address required for the
delivery
• WinCC Basic to
WinCC Comfort V12 2)
• WinCC Comfort to
WinCC Advanced V12
• WinCC Advanced to WinCC
Professional 512 PowerTags V12
• WinCC Professional Powerpack
512 PowerTags to
4096 PowerTags V12
• WinCC Professional Powerpack
4096 PowerTags to max.
PowerTags
6AV2101-2AA02-0BJ5
6AV2102-2AA02-0BJ5
6AV2103-2AD02-0BJ5
6AV2103-2DH02-0BJ5
6AV2103-2HX02-0BJ5
The contract is automatically
extended by a further year unless
canceled at least 12 weeks prior to
expiration.
Software Update Service
(Standard Edition)
The delivery is implemented
according to the number of ordered
SUS products (e.g. 10 upgrade
packages with 10 DVDs, 10 USB
flash drives, etc.)
• WinCC Comfort
• WinCC Advanced
• WinCC Professional
512 PowerTags
• WinCC Professional
4096 PowerTags
• WinCC Professional
max. PowerTags
6AV6612-0AA00-0AL0
6AV6613-0AA00-0AL0
6AV2103-0DA00-0AL0
6AV2103-0HA00-0AL0
6AV2103-0XA00-0AL0
Software Update
Service (Compact Edition)
The delivery items are combined.
For several contracts, only 1 package with 1 data medium set, 1 USB
flash drive with the corresponding
number of licenses and the corresponding number of CoLs will be
supplied.
Delivery items to be combined must
be ordered as one item.
• WinCC Comfort
• WinCC Advanced
• WinCC Professional
512 PowerTags
• WinCC Professional
4096 PowerTags
• WinCC Professional
max. PowerTags
6AV6612-0AA00-0AM0
6AV6613-0AA00-0AM0
6AV2103-0DA00-0AM0
6AV2103-0HA00-0AM0
6AV2103-0XA00-0AM0
Online software delivery (OSD) 1)
Software Update Service
(Download)
All deliveries to be downloaded.
E-mail address required for the
delivery
• WinCC Comfort
• WinCC Advanced
• WinCC Professional
512 PowerTags
• WinCC Professional
4096 PowerTags
• WinCC Professional
max. PowerTags
4/10
Siemens ST 80 / ST PC · 2013
6AV6612-0AA00-0AY0
6AV6613-0AA00-0AY0
6AV2103-0DA00-0AY0
6AV2103-0HA00-0AY0
6AV2103-0XA00-0AY0
1)
Current information and availability regarding the new delivery package
can be found at:
http://www.siemens.com/tia-online-software-delivery
2)
Valid only for order numbers 6AV2100-0AA02-0AA5 and
6AV2100-0AA02-0AH5
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
■ Ordering data
Order No.
Order No.
Upgrades
Upgrades
WinCC V11 -> WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
• SIMATIC WinCC Basic V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Comfort V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Advanced
V12 SP1 Upgrade V11 -> V12 SP1
• SIMATIC WinCC Professional
512 PowerTags V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Professional
4096 PowerTags V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Professional
max. PowerTags V12 SP1
Upgrade V11 -> V12 SP1
WinCC flexible 2008 ->
WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
• WinCC flexible 2008 Compact to
WinCC Comfort V12 SP1
• WinCC flexible 2008 Standard to
WinCC Comfort V12 SP1
• WinCC flexible 2008 Advanced to
WinCC Advanced V12 SP1
6AV2101-4AB02-0AE5
Online software delivery (OSD) 1)
Upgrade license, software and
license key download,
e-mail address required for the
delivery
• WinCC flexible 2008 Compact to
WinCC Comfort V12 SP1
• WinCC flexible 2008 Standard to
WinCC Comfort V12 SP1
• WinCC flexible 2008 Advanced to
WinCC Advanced V12 SP1
6AV2101-4AB02-0AK5
Online software delivery (OSD) 1)
Floating license, software
and license key download
e-mail address required for the
delivery
• SIMATIC WinCC Basic V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Comfort V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Advanced
V12 SP1
Upgrade V11 -> V12 SP1
1)
6AV2100-3AA02-0AE5
6AV2101-3AA02-0AE5
6AV2102-3AA02-0AE5
6AV2103-3DA02-0AE5
6AV2103-3HA02-0AE5
6AV2103-3XA02-0AE5
6AV2100-3AA02-0AK5
6AV2101-3AA02-0AK5
6AV2102-3AA02-0AK5
WinCC V7 RC -> WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
• Upgrade
SIMATIC WinCC V7.0 RC 128 ->
WinCC Professional
512 PowerTags V12 SP1 and
WinCC RT Professional
128 PowerTags
• Upgrade
SIMATIC WinCC V7.0 RC 512 ->
WinCC Professional
512 PowerTags V12 SP1 and
WinCC RT Professional
512 PowerTags
• Upgrade
SIMATIC WinCC V7.0 RC 2048 ->
WinCC Professional
4096 PowerTags V12 SP1 and
WinCC RT Professional
2048 PowerTags
• Upgrade
SIMATIC WinCC V7.0 RC 8192 ->
WinCC Professional
max. PowerTags V12 SP1 and
WinCC RT Professional
8192 PowerTags
• Upgrade
SIMATIC WinCC V7.0 RC 65536 ->
WinCC Professional
max. PowerTags V12 SP1 and
WinCC RT Professional
65536 PowerTags
6AV2101-4BB02-0AE5
6AV2102-4AA02-0AE5
6AV2101-4BB02-0AK5
6AV2102-4AA02-0AK5
4
6AV2103-4BD02-0AE5
6AV2103-4DD02-0AE5
6AV2103-4FH02-0AE5
6AV2103-4KX02-0AE5
6AV2103-4MX02-0AE5
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
■ More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
Siemens ST 80 / ST PC · 2013
4/11
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
SIMATIC WinCC (TIA Portal) Runtime
■ Overview
SIMATIC WinCC Runtime Professional
visualization software
• PC-based operator control and monitoring system for visualization and operator control of processes, production flows,
machines and plants in all sectors – from the simple singleuser station through to distributed multi-user systems and
cross-location solutions with web clients. WinCC Runtime
Professional is the information hub for corporation-wide
vertical integration.
• Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
• Basic package expandable by means of option packages
• Also included are APIs for the Runtime to utilize the open
programming interfaces
4
SIMATIC WinCC Runtime Advanced
visualization software
• PC-based HMI solution for single-user systems directly at the
machine
• Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts
• Basic package expandable by means of option packages
• Can be integrated into automation solutions based on
TCP/IP networks
• Expanded service concepts with remote operation,
diagnostics and administration over the intranet and Internet
in combination with email communication
4/12
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
■ Overview
PC-based HMI solution for single-user systems directly at the
machine. SIMATIC WinCC Runtime Advanced is configured with
the SIMATIC WinCC Advanced or SIMATIC WinCC Professional
configuration software.
■ Benefits
• Functions for all visualization tasks:
- Operator functions
- Graphics and trend displays
- Alarm logging
- Report system
- Archiving (option)
- Recipe management (option)
- Audit Trail (option)
• Flexible runtime functionality due to Visual Basic scripts
• Innovative service concepts with remote operation,
diagnostics and administration via intranet and Internet as
well as e-mail communication to increase availability (option)
• Support for simple distributed automation solutions based on
TCP/IP networks at the machine level (option)
• Part of the Totally Integrated Automation Portal
- Direct access to the tag and message configuration of the
SIMATIC controller
- Excellent support of the new SIMATIC S7-1500 controller
With symbolic addressing
Access to the new memory-optimized data blocks
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity
■ Application
SIMATIC WinCC Runtime Advanced is the high-performance
visualization software for simple, machine-oriented visualization
tasks. It can be used as a single-user solution for all automation
applications in production automation, process automation and
building services automation.
SIMATIC WinCC Runtime Advanced can be used in combination
with the following HMI devices:
• SIMATIC Panel PC: IPC277D, Panel PC 477B, HMI IPC477C,
IPC477D, Panel PC 577B, HMI IPC577C, Panel PC 677B,
HMI IPC677C
• SIMATIC Box PC: IPC227D, Box PC 427B, IPC427C,
IPC427D, Box PC 627B, IPC627C, Box PC 827B, IPC827C
• SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
• SIMATIC modular Embedded Controller: EC31
• SINUMERIK PC: PCU 50.3, PCU 50.5
• Standard PCs with resolutions (W x H in pixels) of:
- 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024,
1600 x 1200
- Widescreen format: 800 x 480, 1280 x 800, 1366 x 768,
1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200,
1980 x 1080
4
Siemens ST 80 / ST PC · 2013
4/13
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
■ Design
SIMATIC WinCC Runtime Advanced is available as a software
package with 128, 512, 2 048 or 4 096 PowerTags.
The term PowerTags is used to identify process variables and
area pointers that have a process link to the controller.
Variables without process link, constant limit values of variables,
and messages (up to 4 000 bit-triggered messages) are also
available for additional system performance.
The range of functions of WinCC Runtime Advanced includes
the centralized HMI components for visualizing and reporting,
and it can be expanded to suit requirements and costs by using
optional packages.
SIMATIC WinCC Runtime Advanced is configured with the
SIMATIC WinCC Advanced or SIMATIC WinCC Professional
configuration software.
■ Function
Visualization via Windows-compliant user interface
4
Made up of parameterizable screen objects and faceplates
created on a project-specific basis:
• Numeric and alphanumeric input/output fields
• Static text and graphic display plus vector graphics
• Dynamizable graphics from HMI symbol library
• Bar graph, trend curve graph with scroll and zoom function as
well as read line
• Signal-specific text and graphic lists
• Buttons and switches for operator-process communication
• Editing fields for process values (signals)
• Analog display, slider as example for further screen objects
• Project-specific faceplates created from basic objects of the
system
• Graphic displays for various standard graphic formats,
e.g. bitmaps, .jpg, .wmf
4/14
Siemens ST 80 / ST PC · 2013
Alarms and messages
• Discrete alarms and analog alarms as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7
• The new alarm and diagnostics concept of the S7-1500
controller is also supported
• Freely-definable alarm classes for definition of acknowledgment response and display of alarm events
Logging of alarms and process values 1)
• Logging in files (e.g. CSV or TXT file) and Microsoft SQL
databases
• Online evaluation of process value and alarm logs
• Evaluation of process value and alarm logs using standard
Microsoft tools such as Excel
Recipes 1)
• Generation of data records for machine data or production
data
• Display or entry of data records via a configurable screen
object or via process screens distributed within the project
• Transmission of data records from or to the controller
• Import/export of data records from/to CSV files for further
processing with other tools (e.g. MS Excel)
1)
Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
Documentation of process data, alarm events, and recipes
• Time or event-driven report output
• User-definable layout
Flexible expansion of integrated system function using
Visual Basic script
Language support for multilingual projects
• Up to 32 online languages
• Language-dependent texts and graphics
• Language selection during runtime
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
■ Function (continued)
User-oriented access protection according to requirements of
regulated sectors
• Authentication with user ID and password
• User group-specific rights
• Central system-wide user administration based on
SIMATIC Logon1)
• Monitoring of changes by operators in runtime operation1)
• Recording of operator actions in an Audit Trail 1)
Onboard controller connection to many different controllers
• Communication via native drivers and standard OPC channel
• Simultaneous connection using several protocols: OPC Client
and SIMATIC HMI HTTP protocol are additive, i.e. they can be
used in conjunction with other controller connections
Open communication between HMI systems and with higherlevel systems
• OPC server
- Use of the visualization system as a data server
(OPC Server) for higher-level automation components,
e.g. control systems or systems in the office area
- OPC-DA-Server: tags, e.g. process values
• Communication between HMI systems is established on
the basis of Ethernet networks, or via the Intranet/Internet
- Read and write access to tags. The WinCC Runtime
Advanced or SIMATIC Panels provide other SIMATIC HMI
systems or office applications with data (variables)
• Sending of e-mails on demand or event-driven
- e.g. to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
- The optional use of e-mail/SMS gateways enables access to
standard networks (external service provider required)
• System diagnostics via device-specific HTML pages;
the following functions are available:
- Starting and stopping the HMI runtime for maintenance
- Remote access to recipe data records, passwords and information specific to the HMI system
- Access to the HMI system files via a file explorer
- Download of configuration data via the Intranet/Internet
- Supplement with own HTML pages
WinCC [email protected]
for the remote control via the Intranet and Internet 1)
• Display and control of process screens on remote PC or Panel
• A SIMATIC HMI system can be used to control or monitor
another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with
head end or control room
WinCC ControlDevelopment
for extending the functionality by adding own Controls 1)
• Development of proprietary VB.net or C# Controls for
integration in SIMATIC WinCC Runtime Advanced
1)
Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
System prerequisites
SIMATIC WinCC
Runtime Advanced
Processor type (min.) 1)
All processors of the SIMATIC IPC,
Pentium III or processor running at
500 MHz or comparable
RAM (min.) 2)
512 MB
Free hard disk space 3)
2 GB on system drive "C:"
Operating systems
32-bit operating systems
• Microsoft Windows XP Professional
SP3
• Windows Embedded Standard
2009 (for IPC / IPC2x7D,
HMI IPC4x7C only)
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008
StdE SP2
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Embedded
Standard 7 SP1 (for IPC / IPC2x7D,
HMI IPC4x7C only)
64-bit operating systems
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008 R2
Standard Edition SP1
DVD-ROM
Optical drive
1)
In combination with options, more powerful systems may be required
2)
The required RAM is determined primarily by the size of the graphics used.
3)
Without taking archives into account.
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past: Size of swap
file = 3 x size of RAM.
For further information, refer to your Windows documentation.
Siemens ST 80 / ST PC · 2013
4/15
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
■ Technical specifications
The following tables of system limitations provide assistance in
estimating whether a specific project is still within the system
limitations for WinCC Runtime Advanced.
Logs
The stated maximum values are not additive.
Number of logs
100
We cannot guarantee proper functioning of configurations that
make full use of all system limits on the HMI devices.
Number of entries per log
(including all log segments) 3)
500 000
In addition to the limitations specified, allowances must be
made for restrictions in configuration memory resources.
Number of log segments
400
Cyclical trigger for tag logging
1s
Number of tags that can be logged
per log
6 144
SIMATIC WinCC
Runtime Advanced
Trends
Tags
Number of tags in the project
6 144
Number of PowerTags
128 –4 096
Number of elements per array
1 600
Number of local tags
2 048
Alarms
4
SIMATIC WinCC
Runtime Advanced
Number of trends
800
Text lists and graphics lists
Number of graphic lists
500
Number of text lists
500
Number of entries per text or
graphic list
3 500
Number of alarm classes
32
Number of graphic objects
2 000
Number of discrete alarms
4 000
Number of text elements
30 000
Number of analog alarms
500
Scripts
Length of an alarm in characters
80
Number of scripts
Number of process values per alarm
8
Communication
Size of the alarm buffer
1 024
Number of connections
8
Number of queued alarm events
500
Number of connections based on
"SIMATIC HMI HTTP"
16
Number of screens
500
4 4)
Number of fields per screen
400
Maximum number of connected
[email protected] (including a service
client)
Number of tags per screen
400
Help system
Number of complex objects per
screen1)
40
Number of characters in a help text
Screens
Number of elements per recipe
999
2)
2 000
User data length in KB per data
record
256
Number of data records per recipe
5 000
4/16
320
Languages
Recipes
Number of recipes
200
Siemens ST 80 / ST PC · 2013
Number of runtime languages
32
Scheduler
Time-triggered tasks 5)
48
User administration
Number of user groups
50
Number of user rights
32
Number of users
100
1)
Complex objects are: Bars, sliders, symbol library, clock, and all objects
from the Controls area.
2)
When using arrays, each array element represents a recipe element
3)
For the "segmented circular log" logging method, the number of entries for
all sequence logs is valid. The product derived from the number of circular
logs times the number of data records in this log may not be exceeded.
4)
Up to three [email protected] can interconnect with the [email protected] on
Panel PC 477.
5)
Event-triggered tasks are not relevant for the system limits.
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
■ Ordering data
Order No.
Order No.
Basic Packages
Online software delivery (OSD) 2)
SIMATIC WinCC Runtime
Advanced V12 SP1
Single license, software and license
key download.
E-mail address required for the
delivery.
• WinCC Runtime Advanced
128 PowerTags to
WinCC Runtime Professional
128 PowerTags
• WinCC Runtime Advanced
512 PowerTags to
WinCC Runtime Professional
512 PowerTags
• WinCC Runtime Advanced
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags
• WinCC Runtime Advanced
4096 PowerTags to
WinCC Runtime Professional
4096 PowerTags
Software and documentation on
DVD, including options software 1)
Single license, license key on
USB stick
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
6AV2104-0BA02-0AA0
6AV2104-0DA02-0AA0
6AV2104-0FA02-0AA0
6AV2104-0HA02-0AA0
Online software delivery (OSD) 2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
6AV2104-0BA02-0AH0
6AV2104-0DA02-0AH0
6AV2104-0FA02-0AH0
6AV2104-0HA02-0AH0
Powerpacks
SIMATIC WinCC Runtime
Advanced V12
(without version change)
Single license, license key only
on USB stick for PowerTags from
• 128 PowerTags to 512 PowerTags
• 512 PowerTags to 2048 PowerTags
• 2048 PowerTags to
4096 PowerTags
6AV2104-2BD02-0BD0
6AV2104-2DF02-0BD0
6AV2104-2FH02-0BD0
Online software delivery (OSD) 2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• 128 PowerTags to 512 PowerTags
• 512 PowerTags to 2048 PowerTags
• 2048 PowerTags to
4096 PowerTags
6AV2104-2BD02-0BJ0
6AV2104-2DF02-0BJ0
6AV2104-2FH02-0BJ0
6AV2105-2DD02-0AJ0
6AV2105-2FF02-0AJ0
6AV2105-2HH02-0AJ0
6AV2105-2BB12-0AC0
4
6AV2105-2DD12-0AC0
6AV2105-2FF12-0AC0
6AV2105-2HH12-0AC0
Upgrades
SIMATIC WinCC Runtime
Advanced V12 to
SIMATIC WinCC Runtime
Professional V12 SP1
Single license, software and documentation on DVD, license key on
USB stick for PowerTags from
• WinCC Runtime Advanced
128 PowerTags to
WinCC Runtime Professional
128 PowerTags
• WinCC Runtime Advanced
512 PowerTags to
WinCC Runtime Professional
512 PowerTags
• WinCC Runtime Advanced
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags
• WinCC Runtime Advanced
4096 PowerTags to
WinCC Runtime Professional
4096 PowerTags
SIMATIC WinCC Runtime
Advanced to
SIMATIC WinCC Runtime
Professional ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 128 PowerTags
-> Runtime Professional
128 PowerTags ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 512 PowerTags
-> Runtime Professional
512 PowerTags ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 2048 PowerTags
-> Runtime Professional
2048 PowerTags ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 4096 PowerTags
-> Runtime Professional
4096 PowerTags ASIA V12 SP1
6AV2105-2BB02-0AJ0
WinCC V11 to WinCC V12 SP1
SIMATIC WinCC Runtime
Advanced V11 to
SIMATIC WinCC Runtime
Advanced V12 SP1
6AV2105-2BB02-0AC0
6AV2105-2DD02-0AC0
6AV2105-2FF02-0AC0
6AV2105-2HH02-0AC0
Software and documentation on
DVD, including options software
Single license, license keys on
USB stick for
• SIMATIC WinCC Runtime
Advanced 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3BB02-0AE0
6AV2104-3DD02-0AE0
6AV2104-3FF02-0AE0
6AV2104-3HH02-0AE0
1)
Runtime licenses for WinCC flexible Runtime Advanced options must
be purchased separately for each target system
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Siemens ST 80 / ST PC · 2013
4/17
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
■ Ordering data
Order No.
Online software delivery (OSD) 2)
Single license, software and
license key download.
E-mail address required for the
delivery.
• SIMATIC WinCC Runtime
Advanced 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3BB02-0AK0
6AV2104-3DD02-0AK0
6AV2104-3FF02-0AK0
6AV2104-3HH02-0AK0
SIMATIC WinCC flexible 2008
to SIMATIC WinCC Runtime
Advanced V12 SP1
4
6AV2107-4XP00-0BF0
Online software delivery (OSD) 2)
Upgrades WinCC flexible 2008
to WinCC V12 SP1
Software and documentation on
DVD, including options software
single license, license keys on
USB stick for
• WinCC flexible 2008 Runtime
128 PowerTags to
WinCC Runtime Advanced
128 PowerTags 1)
• WinCC flexible 2008 Runtime
512 PowerTags to
WinCC Runtime Advanced
512 PowerTags 1)
• WinCC flexible 2008 Runtime
2048 PowerTags to
WinCC Runtime Advanced
2048 PowerTags 1)
• WinCC flexible 2008 Runtime
4096 PowerTags to
WinCC Runtime Advanced
4096 PowerTags 1)
Order No.
SIMATIC WinCC flexible Panel
Options to
SIMATIC WinCC V11 / V12
Panel Options
• WinCC flexible /Audit
for SIMATIC Panels to
SIMATIC WinCC Audit for
SIMATIC Panels
• WinCC flexible /[email protected]
for SIMATIC Panel to
SIMATIC WinCC [email protected]
for SIMATIC Panels
• WinCC flexible /[email protected]
for SIMATIC Panels to
SIMATIC WinCC [email protected]
for SIMATIC Panels
6AV2104-4BB02-0AE0
6AV2104-4DD02-0AE0
Single license, license key
download only.
E-mail address required for
the delivery.
SIMATIC WinCC flexible Panel
Options to SIMATIC WinCC
V11 / V12 Panel Options
• WinCC flexible /Audit for
SIMATIC Panels to
SIMATIC WinCC Audit for
SIMATIC Panels
• WinCC flexible /[email protected]
for SIMATIC Panel to
SIMATIC WinCC [email protected]
for SIMATIC Panels
• WinCC flexible /[email protected]
for SIMATIC Panels to
SIMATIC WinCC [email protected]
for SIMATIC Panels
6AV2107-4XP00-0BK0
6AV2104-4FF02-0AE0
6AV2104-4HH02-0AE0
Online software delivery (OSD) 2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• WinCC flexible 2008 Runtime
128 PowerTags to
WinCC Runtime Advanced
128 PowerTags 1)
• WinCC flexible 2008 Runtime
512 PowerTags to
WinCC Runtime Advanced
512 PowerTags 1)
• WinCC flexible 2008 Runtime
2048 PowerTags to
WinCC Runtime Advanced
2048 PowerTags 1)
• WinCC flexible 2008 Runtime
4096 PowerTags to
WinCC Runtime Advanced
4096 PowerTags 1)
6AV2104-4BB02-0AK0
6AV2104-4DD02-0AK0
6AV2104-4FF02-0AK0
6AV2104-4HH02-0AK0
■ More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
4/18
Siemens ST 80 / ST PC · 2013
1)
Each including 1 upgrade license to the WinCC Runtime Advanced
options
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Overview
PC-based operator control and monitoring system for visualization and operator control of processes, production flows,
machines and plants in all sectors – from the simple single-user
station through to distributed multi-user systems and crosslocation solutions with web clients.
SIMATIC WinCC Runtime Professional is the information hub for
corporation-wide vertical integration. SIMATIC WinCC Runtime
Professional is configured with the SIMATIC WinCC Professional
configuration software.
■ Benefits
• Functions for all visualization tasks:
- Operator functions
- Graphics and trend displays
- Alarm logging
- Report system
- Archiving (option)
- Recipe management (option)
• Universally scalable
- Expandable from single station to client-server configurations
- Process visualization via the web with the
WinCC WebNavigator
• Open standards for easy integration
- Efficient real-time database MS SQL Server
- Open for application modules with ActiveX controls
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication
• Part of the Totally Integrated Automation Portal
- Direct access to the tag and message configuration of the
SIMATIC controller
- Excellent support of the new SIMATIC S7-1500 controller
With symbolic addressing
Access to the new memory-optimized data blocks
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity
■ Application
SIMATIC WinCC Runtime Professional is designed for visualization and operation of processes, manufacturing cycles,
machines and plants. With its powerful process interface,
especially to the SIMATIC family, and the secure data logging,
WinCC Runtime Professional enables solutions for the process
control.
The sector-neutral basic system enables universal usage in all
automation applications.
SIMATIC WinCC Runtime Professional can be used in combination with the following HMI devices:
SIMATIC PCs:
• SIMATIC Panel PC: HMI IPC477C, IPC477D, Panel PC 577B,
HMI IPC577C, Panel PC 677B, HMI IPC677C
• SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B,
IPC627C, IPC827C
• SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
• Standard PC
■ Design
SIMATIC WinCC Runtime Professional is available as a software
package with 128, 512, 2 048, 4 096, 8 192, 65 536 PowerTags.
PowerTags are data points that are connected to controllers or
other data sources via a WinCC Runtime Professional channel.
Up to 32 alarms can be obtained from one data point. Moreover,
internal tags without coupling are available for additional system
performance.
WinCC Runtime Professional also contains 500 archive tags.
Additional archive licenses can be obtained for greater quantity
structures.
Licenses for a multi-user configuration
The system software with the required number of PowerTags and
additionally the SIMATIC WinCC Server for Runtime Professional
option must be installed on the server. For the clients in the basic
configuration, a SIMATIC WinCC Client for Runtime Professional
license is sufficient.
■ Function
Visualization via Windows-compliant user interface
Made up of parameterizable screen objects and faceplates
created on a project-specific basis:
• Numeric and alphanumeric input/output fields
• Static text and graphic display plus vector graphics
• Dynamizable graphics from HMI symbol library
• Bar graph, trend curve graph with scroll and zoom function as
well as read line
• Signal-specific text and graphic lists
• Buttons and switches for operator-process communication
• Editing fields for process values (signals)
• Analog display, slider as example for further screen objects
• Project-specific faceplates created from basic objects of the
system
• Graphic displays for various standard graphic formats,
e.g. bitmaps, .jpg, .wmf
Alarms and messages
• Discrete alarms and analog alarms, as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7
• The new alarm and diagnostics concept of the S7-1500
controller is also supported
• Freely-definable alarm classes for definition of acknowledgment response and display of alarm events
Logging of alarms and process values 1)
• Signaling system for detecting and archiving events with
display and control options according to DIN 19235
• Process logging for the acquisition, compression and storage
of measured values
• Online evaluation of process value and alarm logs
1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
Siemens ST 80 / ST PC · 2013
4/19
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Function (continued)
Recipes 1)
• Generation of data records for machine data or production
data
• Display or entry of data records via a configurable screen
object or via process screens distributed within the project
• Transmission of data records from or to the controller
• Import/export of data records for further processing with other
tools (e.g. MS Excel)
Documentation of process data, alarm events, and recipes
• Time or event-driven report output
• User-definable layout
Flexible expansion by means of Visual Basic Script and ANSI-C
• Programming interfaces for individual access to data and
functions of WinCC Runtime Professional and for the
integration in user programs with VBA, VB Script, C-API,
C-Script (ANSI-C)
Language support for multilingual projects
• Language-dependent texts and graphics
• Language selection during runtime
4
Onboard controller connection to many different controllers
• Communication via native drivers and standard OPC channel
• For communication with subordinate controls
(SIMATIC protocols, PROFIBUS DP, PROFIBUS FMS, DDE
and OPC server included in the scope of delivery)
Open communication between HMI systems and
with higher-level systems
• OPC-Server
Use of the visualization system as a data server (OPC-Server)
for higher-level automation components such as control
systems or systems in the office sector
- OPC-DA-Server: tags, e.g. process values
- OPC-HDA-Server: logged process values
- OPC-A&E-Server: Alarms
- OPC-XML-DA-Server: tags, e.g. process values
- OPC-UA-DA-Server: tags, e.g. process values
• OLE DB Server
- Standardized and user-friendly access to WinCC log data
(MS SQL Server 2005).
- Access is via the OLE-DB Provider supplies all WinCC log
data available along with the accompanying process values,
as well as alarm and user texts.
- The WinCC OLE-DB provider also supports analysis
functions such as minimum, maximum, alarm hit list, etc.
• WinCC WebNavigator for Runtime Professional 1)
- Option for SIMATIC WinCC Runtime Professional for
operating and monitoring plants over the Internet, company
Intranet or LAN.
- Configuration from a web server with the SIMATIC WinCC
Runtime Professional software as a single-user, client or
server version and a web client that enables operator control
and monitoring of a current WinCC Runtime Professional
project via an Internet browser with ActiveX support. The
WinCC basic system does not have to be installed on the
client computer.
• WinCC DataMonitor for Runtime Professional 1)
- The WinCC DataMonitor is used for displaying and evaluating current process states and historical data on office PCs
using standard tools such as Microsoft Internet Explorer or
Microsoft Excel.
The DataMonitor Client is supported by a web server with
current and historic process data and alarms. All staff
ranging from machine operators to corporate managers can
use the DataMonitor to obtain information.
1)
4/20
Siemens ST 80 / ST PC · 2013
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Function (continued)
■ Integration
WinCC ControlDevelopment
for extending the functionality by adding own Controls 1)
• Development of proprietary VB.net or C# Controls for
integration in WinCC Runtime Professional
1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
System prerequisites
SIMATIC WinCC
Runtime Professional
Processor type (min.) 1)
• Windows XP: 2.5 GHz P4 or
comparable, Pentium M, 1.6 GHz
or comparable
• Windows 7 (32-bit): 3.5 GHz P4
or comparable, dual core
• Windows Server 2003: 3 GHz P4
or comparable
• Windows Server 2008: 3 GHz P4
or comparable, dual/multi core
RAM (min.) 2)
2 GB
Free hard disk space 3)
2 GB on system drive "C:"
Operating systems
32-bit operating systems
• Microsoft Windows XP Professional
SP3
• Windows Embedded Standard
2009 (for IPC / IPC2x7D, HMI
IPC4x7C only)
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008
StdE SP2
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Embedded
Standard 7 SP1 (for IPC / IPC2x7D,
HMI IPC4x7C only)
Integration in company-wide solutions
(IT and business integration)
WinCC Runtime Professional is strictly based on Microsoft
technology, which provides for the greatest possible compatibility and integration ability. ActiveX and .net Controls support
technology and sector-specific expansions.
Cross-manufacturer communication is also a simply exercise.
The reason: WinCC Runtime Professional can be used as an
OPC client and server, and in addition to access to current
process values, it also supports standards such as OPC HDA
(Historical Data Access), OPC Alarm & Events, OPC UA Data
Access and OPC XML Data Access. Just as important: Visual
Basic Scripting (VBS) as an easy-to-learn, open Runtime
language. If desired, professional application developers can
also use ANSI-C.
WinCC Runtime Professional integrates a powerful and scalable
Historian function based on the Microsoft SQL Server in the
basic system.
Thus the user is given all possibilities: from high-performance
archiving of current process data, to long-term archiving with
high data compression, through to a central information
turntable in form of a company-wide Process Historian.
Open interfaces form the basis for an effective IT and business
integration.
64-bit operating systems
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008 R2
Standard Edition SP1
Graphics card
32 MB RAM, 24 bit color depth
Network
Ethernet 10 Mbit/s or higher
Optical drive
DVD-ROM
1)
In combination with options, more powerful systems may be required
2)
The required RAM is determined primarily by the size of the graphics used.
3)
Without taking archives into account.
Note:
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past:
Size of swap file = 3 x size of RAM.
For further information, refer to your Windows documentation.
Siemens ST 80 / ST PC · 2013
4/21
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Technical specifications
The following tables of system limits provide assistance in
estimating whether a specific project is still within the system
limitations for WinCC Runtime Professional. The stated maximum
values are not additive.
We cannot guarantee proper functioning of configurations that
make full use of all system limits on the HMI devices. In addition
to the limitations specified, allowances must be made for restrictions in configuration memory resources.
SIMATIC WinCC
Runtime Professional
Alarms
Logs
Trend views per screen
25
Trends per trend view
80
Tables per screen
25
Columns per table
12
Values per table
30 000
Logs per single-user station/server
100
Log tags per single-user station/
server 7)
8 000
Configurable alarms
per server/single user
20 000
PowerTags per alarm line
10
Trend views per image
25
User text blocks per alarm line
10
Trends per trend view
80
Alarm classes
(incl. system alarm classes)
18
User administration
Number of user groups
128
Alarm types
16
Number of user rights
999
Alarm priorities
17 (0...16)
Number of users
128
Alarms per alarm log
Unlimited 1)
Configurations – Quantity structure
in a multi-user system
Alarms per short-term log list
1 000
WinCC clients in a system
32 8) 9)
Alarms per long-term log list
1 000 2)
Web clients in a system
50 10)
Alarms per alarm display
5 000 3)
Trends
Alarms in Runtime
4
SIMATIC WinCC
Runtime Professional
Screens
Objects per screen 4)
3 0005)
Levels per screen
32
Screens per project
1 000 5)
Instances of fixed faceplates
in a process screen
31 instances of the same picture
type
Screen size in pixels
10 000 x 10 000
Nesting levels of screen objects
20
Recipes
000 5)
Number of recipes
1
Number of recipe elements
500 6)
Number of recipe data records
Number of views
4/22
3 000 6)
Unlimited
Siemens ST 80 / ST PC · 2013
5)
1)
Limited by system resources.
2)
On single-user station or server or on client per server if "LongTimeArchiveConsistency" is set to "No". On single-user station, server, or client if
"LongTimeArchiveConsistency" is set to "Yes".
3)
On single-user station or server or on client per server.
4)
The number and complexity of the objects affect the performance.
5)
Limited by system resources.
6)
The sum of the number of recipe elements and number of data records
must not exceed a value of 320,000.
7)
Dependent on the Logging Powerpack used for the log tags.
500 log tags are contained in the basis version.
8)
If the server is also used as an operating unit, the number of clients for this
server is reduced to four.
9)
Mixed configuration: 32 Clients + 3 Web Clients
10)
Mixed configuration: 50 Web Clients + 1 WinCC Client
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Ordering data
Order No.
Order No.
Basic software
Powerpacks
SIMATIC WinCC
Runtime Professional V12 SP1
SIMATIC WinCC
Runtime Professional V12 and
SIMATIC WinCC
Runtime Professional ASIA V12
For PC systems;
incl. software options 1),
language/script versions:
DE, EN, FR, IT, ES
Single License, on DVD
incl. licensing, on USB stick, for:
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
• 8192 PowerTags
• 65535 PowerTags
6AV2105-0BA02-0AA0
6AV2105-0DA02-0AA0
6AV2105-0FA02-0AA0
6AV2105-0HA02-0AA0
6AV2105-0KA02-0AA0
6AV2105-0MA02-0AA0
Incl. 500 archive tags each
Online software delivery (OSD) 3)
Single license, software and
license key download.
E-mail address required
for the delivery.
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
• 8192 PowerTags
• 65535 PowerTags
6AV2105-0BA02-0AH0
6AV2105-0DA02-0AH0
6AV2105-0FA02-0AH0
6AV2105-0HA02-0AH0
6AV2105-0KA02-0AH0
6AV2105-0MA02-0AH0
Incl. 500 archive tags each
SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
For PC systems;
incl. software options 1),
language/script versions:
EN, CHs, CHt, KOR, JPN
Single License, on DVD
incl. licensing, for:
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
• 8192 PowerTags
• 65535 PowerTags
6AV2105-0BA12-0AA0
6AV2105-0DA12-0AA0
6AV2105-0FA12-0AA0
6AV2105-0HA12-0AA0
6AV2105-0KA12-0AA0
6AV2105-0MA12-0AA0
Incl. 500 archive tags each
SIMATIC WinCC Client for
Runtime Professional
• WinCC Client for
Runtime Professional
• WinCC Client for
Runtime Professional
(form of delivery OSD 3))
• WinCC Client for
Runtime Professional ASIA
6AV2107-0DB02-0AA0
6AV2107-0DB02-0AH0
6AV2107-0DB12-0AA0
1)
Runtime licenses for WinCC Runtime Professional options must be
purchased separately for each target system.
2)
Each including 1 upgrade license to the WinCC Runtime Professional
options.
3)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Single license, license key only on
USB sticks for PowerTags from
• 128 to 512 PowerTags
• 512 to 2048 PowerTags
• 2048 to 4096 PowerTags
• 4096 to 8192 PowerTags
• 8192 to 65536 PowerTags
6AV2105-2BD02-0BD0
6AV2105-2DF02-0BD0
6AV2105-2FH02-0BD0
6AV2105-2HK02-0BD0
6AV2105-2KM02-0BD0
Online software delivery (OSD) 3)
Single license, license key
download only.
E-mail address required
for the delivery.
• 128 to 512 PowerTags
• 512 to 2048 PowerTags
• 2048 to 4096 PowerTags
• 4096 to 8192 PowerTags
• 8192 to 65536 PowerTags
6AV2105-2BD02-0BJ0
6AV2105-2DF02-0BJ0
6AV2105-2FH02-0BJ0
6AV2105-2HK02-0BJ0
6AV2105-2KM02-0BJ0
Upgrades WinCC V11
to WinCC V12 SP1
SIMATIC WinCC
Runtime Professional V11 to
SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC
Runtime Professional ASIA V11
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
Single license, on DVD
incl. licensing on USB stick
• SIMATIC WinCC Runtime
Professional 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 8192 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 65536 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
4
6AV2105-3BB02-0AE0
6AV2105-3DD02-0AE0
6AV2105-3FF02-0AE0
6AV2105-3HH02-0AE0
6AV2105-3KK02-0AE0
6AV2105-3MM02-0AE0
Siemens ST 80 / ST PC · 2013
4/23
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
■ Ordering data
4
Order No.
Order No.
Upgrades WinCC V11
to WinCC V12 SP1
(continued)
Upgrades WinCC V7
to WinCC V12 SP1
(continued)
Online software delivery (OSD) 2)
SIMATIC WinCC V7.0
to SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC V7.0 ASIA
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
• WinCC V7.0 Runtime
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
8192 PowerTags to
WinCC Runtime Professional
8192 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
65536 PowerTags to
WinCC Runtime Professional
65536 PowerTags V12 SP1 1)
• WinCC V7.0 RC/RT128 / RC/RT
Client to WinCC Client for
Runtime Professional V12 SP1
Single license, software and
license key download.
E-mail address required
for the delivery.
• SIMATIC WinCC Runtime
Professional 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 8192 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 65536 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3BB02-0AK0
6AV2105-3DD02-0AK0
6AV2105-3FF02-0AK0
6AV2105-3HH02-0AK0
6AV2105-3KK02-0AK0
6AV2105-3MM02-0AK0
Upgrades WinCC V7
to WinCC V12 SP1
SIMATIC WinCC V7.0
to SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC V7.0 ASIA
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
Single license, on DVD
incl. licensing on USB stick
• WinCC V7.0 Runtime
128 PowerTags to
WinCC Runtime Professional
128 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
512 PowerTags to
WinCC Runtime Professional
512 PowerTags V12 SP1 1)
6AV2105-4BB02-0AE0
6AV2105-4DD02-0AE0
6AV2105-4FF02-0AE0
■ More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
4/24
Siemens ST 80 / ST PC · 2013
6AV2105-4KK02-0AE0
6AV2105-4MM02-0AE0
6AV2107-4DB02-0AE0
6AV2105-4BB02-0AE0
Online software delivery (OSD) 2)
Single license, software and
license key download.
E-mail address required
for the delivery.
• WinCC V7.0 Runtime
128 PowerTags to
WinCC Runtime Professional
128 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
512 PowerTags to
WinCC Runtime Professional
512 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
8192 PowerTags to
WinCC Runtime Professional
8192 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
65536 PowerTags to
WinCC Runtime Professional
65536 PowerTags V12 SP1 1)
• WinCC V7.0 RC/RT128 / RC/RT
Client to WinCC Client for
Runtime Professional V12 SP1
6AV2105-4BB02-0AK0
6AV2105-4DD02-0AK0
6AV2105-4FF02-0AK0
6AV2105-4KK02-0AK0
6AV2105-4MM02-0AK0
6AV2107-4DB02-0AK0
1)
Each including 1 upgrade license to the WinCC Runtime Professional
options.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
■ Overview
Communication – SIMATIC WinCC Runtime Advanced
Protocol
WinCC Advanced is an open visualization system and offers the
option of connecting the most diverse control systems.
Third-party controllers (from WinCC V11.0) 3)
Number of connectable controllers
Current notes and information about OPC servers from many
different suppliers can be found at:
http://www.opcfoundation.org/
WinCC Advanced supports the standards:
• OPC Data Access 2.05a
• OPC UA Data Access 1.01
• OPC XML Data Access 1.00 (client via DCOM/XML gateway)
Protocol
Description
PC interface
Channel for communication
with max. 4 x Allen Bradley
controllers via Ethernet TCP/IP
with Allen Bradley Ethernet IP
protocol
The controllers ControlLogix /
CompactLogix, SLC500 /
MicroLogix and PLC5 are
supported
CP 1612 A2
Allen Bradley DF1
Channel for communication
with Allen Bradley controllers
via DF1 protocol
The controllers SLC500 /
MicroLogix and PLC5 are
supported 3)
COM1/COM2
Mitsubishi MC TCP/IP
Channel for communication with
max. 4 x Mitsubishi controllers
via Ethernet TCP/IP with Mitsubishi MC TCP/IP protocol
The FX3, Q, and iQ/QnUD
controller series are supported
CP 1612 A2
Mitsubishi FX
Channel for communication
with Mitsubishi controllers
via FX protocol
The FX1N, FX2N controllers are
supported
COM1/COM2
HTTP communication for data
exchange between SIMATIC
HMI (client + server) 1)
CP 1612 A2
Modbus TCP/IP
Channel for communication
with max. 4 x Modicon controllers via Ethernet TCP/IP using
the Modbus TCP/IP protocol
The Quantum, Momentum,
Premium, TSX Micro, Compact
and M340 controllers are
supported
CP 1612 A2
Channel for communication via
Ethernet TCP/IP with max. 8 x
SIMATIC S7 controllers
S7-1200, S7-1500
S7-300, S7-400,
S7-200 with CP 243-1
CP 1612 A2
CP 1613 A2
CP 1623
Modbus RTU
Channel for communication
with Modicon controllers via
the Modbus RTU protocol
The Quantum, Momentum,
and Compact controllers are
supported
COM1/COM2
Channel for communication via
MPI, PROFIBUS with max. 8 x
SIMATIC S7 controllers
S7-1200 with CM 1243-5
(DP master), S7-1500
S7-300, S7-400
S7-200 (only passive S7-200)
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623
Omron Link / Multi Link
Channel for communication
with Omron controllers via the
Link/Multi protocol
The CP1x, CJ1x, CJ2H, CS1x,
and CP2MC controllers are
supported
COM1/COM2
Channel for communication via
PPI with
1 x SIMATIC S7-200
(network operation,
e.g. parallel PG possible)
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623
OPC client 1) 4) for
OPC DA, OPC UA DA,
XML DA
Channel for OPC communication, WinCC can acquire data
from OPC server applications
CP 1612 A2
OPC server for OPC DA
Server applications for
OPC communication;
WinCC provides process data
to OPC clients
CP 1612 A2
SIMATIC HMI
Ethernet TCP/IP
(HTTP communication)
SIMATIC S7
Ethernet TCP/IP
(S7 communication)
MPI, PROFIBUS
(S7 communication)
PPI
(PPI protocol)
Software interface
(S7 communication)
Channel for communication via
software interface with WinAC
Cross-manufacturer
SINUMERIK 2)
Ethernet TCP/IP
(S7 communication)
Channel for communication
via Ethernet TCP/IP
with SINUMERIK 840D sl
CP 1612 A2
CP 1613 A2
CP 1623
MPI
(S7 communication)
Channel for communication
via MPI with
SINUMERIK 840D sl
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623
PC interface
Allen Bradley
Ethernet IP
WinCC Advanced permits the parallel coupling of up to
8 controllers.
Connection to third-party controllers
The following "Coupling overview" table lists third-party protocols
and controllers which are directly supported by WinCC
Advanced. Generally it is also possible to connect third-party
controllers via OPC (OLE for Process Control).
Description
1)
HTTP and OPC communication can be used in combination with the other
couplings; regarding SIMATIC Panels that support HTTP or OPC
communication, see the overview under "System interfaces
(WinCC V11)".
2)
"SINUMERIK Operate WinCC RT Advanced" license required;
for further information, see NC 60 Catalog.
3)
For detailed information regarding supported controllers,
see "System interfaces (WinCC V11)"
4)
Application note:
The parallel use of the OPC client channel allows, for example, the
connection to an SNMP OPC Server for visualization of the data
present there. The SNMP OPC Server enables monitoring of any
network components (e.g. switch) that support the SNMP protocol.
Further information can be foundunder SIMATIC NET communications
systems/SNMP OPC Server.
Siemens ST 80 / ST PC · 2013
4/25
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
■ Overview (continued)
Communication – SIMATIC WinCC Runtime Professional
Protocol
WinCC Professional is an open process visualization system and
offers the option of connecting the most diverse control systems.
SIMATIC S7
SIMATIC S7
Released communication software
Only communication software with the listed (or higher) product
versions should be used. Corresponding SIMATIC NET
upgrades are available for the upgrading of older versions.
Number of connectable controllers
With CP 1613, a maximum of 64 S7 controllers can be connected
via Industrial Ethernet; with CP 5611 a maximum of 8 and with
CP 5613 a maximum of 44 S7 controllers can be connected via
PROFIBUS. With approx. 10 or more controllers, the use of
Industrial Ethernet is recommended.
Client-server communication
Communication between the clients and the server is implemented using the TCP/IP protocol. The construction of a
separate PC-LAN is recommended. For small projects with
correspondingly small message frame advent, a SIMATIC NET
Industrial Ethernet can be used for both process communication
(WinCC/server l PLC) and for PC-PC communication
(WinCC/client l WinCC/server)
4
Siemens ST 80 / ST PC · 2013
CP 1612 A2
CP 1613 A2
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623
Channel for communication with
Allen Bradley controllers via
Ethernet TCP/IP with Ethernet IP
protocol
The controllers ControlLogix /
CompactLogix,
SLC500 / MicroLogix,
and PLC5 are supported
CP 1612 A2
Mitsubishi MC TCP/IP
Channel for communication
with Mitsubishi controllers via
Ethernet TCP/IP with
Mitsubishi MC TCP/IP protocol
The FX3, Q, and iQ/QnUD
controller series are supported
CP 1612 A2
Modbus TCP/IP
Channel for communication with
Modicon controllers via Ethernet
TCP/IP using the Modbus TCP/
IP protocol
The Quantum, Momentum, Premium, TSX Micro, Compact and
M340 controllers are supported
CP 1612 A2
OPC client 1) for
OPC DA, OPC XML DA
Channel for OPC communication, WinCC can acquire data
from OPC server applications
CP 1612 A2
OPC server for
OPC DA, OPC UA DA,
OPC XML DA,
OPC A&E, OPC HDA
Server applications for
OPC communication;
WinCC provides process data
to OPC clients
CP 1612 A2
Cross-manufacturer
1)
4/26
Protocol Suite with channel
units for communication with
SIMATIC S7 via
• Ethernet TCP/IP
(S7 communication) to
S7-1200, S7-1500, S7-300,
S7-400
• MPI, PROFIBUS
(S7 communication) to
S7-1200 with CM 1243-5
(DP master), S7-1500, S7-300,
S7-400
• Software interface
(S7 communication)
to Win AC
Allen Bradley
Ethernet IP
Current notes and information about OPC servers from many
different suppliers can be found at:
http://www.opcfoundation.org/
WinCC Professional supports the standards:
• OPC Data Access 2.05a
• OPC Data Access 3.00
• OPC UA Data Access 1.01
• OPC XML Data Access 1.00
• OPC HDA 1.20
• OPC A&E 1.10
PC interface
Third-party controllers (from WinCC V11.0)
Connection to third-party controllers
The following "Coupling overview" table lists third-party protocols
and controllers which are directly supported by WinCC Professional. Generally it is also possible to connect third-party
controllers via OPC (OLE for Process Control).
Description
Application note:
The parallel use of the OPC client channel allows, for example, the
connection to an SNMP OPC Server for visualization of the data present
there.
The SNMP OPC Server enables monitoring of any network components
(e.g. switch) that support the SNMP protocol.
Further information can be foundunder SIMATIC NET communications
systems/SNMP OPC Server.
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
■ Overview (continued)
Industrial Ethernet
SIMATIC S7-400
WinCC
Runtime
Advanced
PROFIBUS
SIMATIC S7-1200
*B67B;;B
SIMATIC S7-300
WinCC Runtime Advanced single-user system
WinCC RT
Professional
Client
4
WinCC RT
Professional
Client
WinCC RT
Professional
Client
WinCC RT
Professional
Client
Industrial Ethernet
WinCC RT
Professional
Server
PROFIBUS
SIMATIC S7-400
*B67B;;B
SIMATIC S7-400
WinCC Runtime Professional multi-user system with operable Server
Siemens ST 80 / ST PC · 2013
4/27
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
■ Overview (continued)
OPC Client
WinCC RT
Professional
Industrial Ethernet
OPC Server
WinCC RT
Advanced
4
SIMATIC S7-300
OPC coupling
4/28
Siemens ST 80 / ST PC · 2013
SIMATIC S7-1200
*B67B;;B
PROFIBUS
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
■ Ordering data
Order No.
Communication
via Industrial Ethernet TCP/IP
CP 1612 A2
6GK1161-2AA01
PCI card (32-bit) for connection of
a programming device or PC to
Industrial Ethernet
(10/100/1000 Mbit/s) with RJ45
connection via SOFTNET S7 and
SOFTNET PG.
For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1612; CP 1612 A2
German/English
• Single license for 1 installation
• Upgrade package for
SIMATIC NET from Edition 2006
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
WinCC Runtime Professional:
SOFTNET-S7 Lean (maximum of
8 connections) or SOFTNET-S7
(maximum of 64 connections) must
be installed (SOFTNET-S7 Lean is
included in the scope of delivery of
WinCC Runtime Professional)
CP 1613-A2
SOFTNET-S7 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)
6GK1161-3AA01
Software for S7 and S5-compatible
communication, incl. PG/OP communication, OPC server and NCM
PC; up to 120 connections, single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, license key
on USB flash drive, Class A
For (32-bit) Windows 7 Ultimate,
Professional;
for CP 1612; CP 1612 A2
German/English
(included in the scope of delivery:
Edition 2008 SP2 (V7.1) )
4
Version 8.0 SP1
For (32-bit) Windows 7 Ultimate,
Professional;
for CP 1613; CP 1613 A2,
CP 1623 German/English
(included in the scope of delivery:
Edition 2008 SP2 (V7.1) )
Edition 2008 SP2 (V7.1)
Software for S7-compatible and
S5-compatible communication
incl. OPC server, PG/OP
communication and NCM PC;
up to 8 connections; single license
for one installation of runtime
software,
software and electronic manual
on CD-ROM;
license key on USB stick; Class A
6GK1704-1LW00-3AE1
S7-1613 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)
Version 8.0 SP1
(included in the scope of delivery of
WinCC V11)
6GK1704-1LW80-3AA0
6GK1704-1LW00-3AE0
PCI card (32 bit) for connecting a
PG/PC to Industrial Ethernet
(communications software must
be ordered separately)
Software for S7 and S5-compatible
communication, incl. OPC server,
PG/OP communication and NCM
PC; up to 64 connections, single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, license key on
USB flash drive, Class A
SOFTNET-S7 Lean Version 8.0
SP1 / Edition 2008 SP2 (V7.1)
For (32-bit) Windows 7 Ultimate,
Professional; for CP 1612;
CP 1612 A2 German/English
(included in scope of supply:
Edition 2008 SP2 (V7.1) )
Edition 2008 SP2 (V7.1)
Software requirement:
WinCC Runtime Advanced:
No further installation is required
(SOFTNET-S7)
For (32-bit) Windows XP Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1612; CP 1612 A2
German/English
• Single license for 1 installation
• Upgrade package for
SIMATIC NET from Edition 2006
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
Order No.
Version 8.0 SP1
Edition 2008 SP2 (V7.1)
6GK1704-1CW80-3AA0
6GK1704-1CW00-3AE0
6GK1704-1CW00-3AE1
For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1613; CP 1613 A2,
CP 1623 German/English
• Single license for 1 installation
• Upgrade package for
SIMATIC NET from Edition 2006
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
CP 1623
6GK1716-1CB80-3AA0
6GK1716-1CB00-3AE0
6GK1716-1CB00-3AE1
6GK1162-3AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
to be ordered separately)
Siemens ST 80 / ST PC · 2013
4/29
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
■ Ordering data
Order No.
Communication via PROFIBUS
PC adapter USB
6ES7972-0CB20-0XA0
Can be used under Windows XP
CP 5611 A2
6GK1561-1AA01
6GK1562-1AA00
6GK1562-1AM00
Software for S7 Communication incl.
PG/OP protocol, FDL, OPC server;
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A
6GK1551-2AA00
Version 8.0 SP1
Comprising CP 5621 (32-bit) and
MPI cable, 5 m
CP 5512
PCMCIA card (CARDBUS 32-bit)
for the connection of a PG/notebook
to PROFIBUS or MPI
(communications software included
in WinCC basic package)
CP 5711
4
For (32-bit) Windows 7 Ultimate,
Professional; for CP 5613 A2,
CP 5623 German/English
6GK1571-1AM00
USB adapter for connecting a
PG/PC to PROFIBUS or MPI
(communications software included
in the WinCC basic package)
4/30
6GK1562-3AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
to be ordered separately)
S7-5613 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
CP 5621 MPI
6GK1561-3AA01
PCI card (32-bit) for connecting
a PC to PROFIBUS
(communications software must
be ordered separately).
CP 5623
PCI Card (32-bit) for connecting a
PG/PC to PROFIBUS
(Communication software included
in the WinCC basic package)
CP 5621
Order No.
CP 5613 A2
Siemens ST 80 / ST PC · 2013
For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 5613 A2, CP 5623
German/English
• Single license for 1 installation
• Upgrade package for
SIMATIC NET from Edition 2006
• Upgrade package
for SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
6GK1713-5CB80-3AA0
6GK1713-5CB00-3AE0
6GK1713-5CB00-3AE1
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
SIMATIC WinCC (TIA Portal) options
■ Overview
Options for SIMATIC Panels,
SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
SIMATIC WinCC Recipes
for SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
• Generation and management of data records for machine or
production data
• Display or entry of data records via a configurable screen
object or via process screens distributed within the project
• Transmission of data records from or to the controller
• Import/export of data records for further processing with other
tools (e.g. MS Excel)
SIMATIC WinCC Logging
for SIMATIC WinCC Runtime Advanced
and SIMATIC WinCC Runtime Professional
• Logging of alarms and process values
• Online evaluation of process value logs and alarm logs
• Evaluation of process value and alarm logs using standard
MS tools such as Excel
SIMATIC WinCC Audit
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
• Recording of operator actions in an Audit Trail
• Electronic signature for important operator actions relevant to
production
• Audit supports users in meeting special quality requirements,
e.g.
- Production plant requiring validation according to 21 CFR
Part 11 (Food Drug Administration law)
- In respect of traceability according to EU 175/2002
(EU directive)
SIMATIC WinCC Server and SIMATIC WinCC Client
for SIMATIC WinCC Runtime Professional
For setting up a high-performance client-server system
• A number of coordinated HMI stations can be operated in a
single group with networked automation systems
• Client/server solution:
- One server can supply up to 32 connected clients with
process and archive data, alarms, screens and reports
- Depending on the size of the plant, up to 12 servers and
32 clients can be employed.
SIMATIC WinCC WebNavigator
for SIMATIC WinCC Runtime Professional
• Operator control and monitoring of plants via the Internet or
the in-house intranet or LAN
• Web Client permits the operator control and monitoring of a
current WinCC Runtime Professional project via an Internet
browser with ActiveX support.
SIMATIC WinCC DataMonitor
for SIMATIC WinCC Runtime Professional
• Display and analysis of current process states and historical
data on office PCs with standard tools.
• Information can be compiled online individually during
runtime via the Internet/Intranet.
SIMATIC WinCC ControlDevelopment
for SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
• Expansion of the basic functionality with proprietary controls.
• Development of proprietary VB.net or C# Controls for
integration in WinCC Runtime Advanced and WinCC Runtime
Professional
SIMATIC Logon
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
and SIMATIC WinCC Runtime Professional
• Creates user administration on a central computer to which
one or more WinCC stations can be connected over Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
• SIMATIC Logon supports the user in combination with the
Audit option in meeting requirements in accordance with
FDA 21 CFR Part 11 and EU178.
SIMATIC WinCC [email protected]
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
• Flexible solution for remote access to HMI systems
• Remote maintenance of machines and plants via the Internet/
Intranet
• Reduced downtimes for machines and plants due to direct
remote access
• Flexible solution for remote access to machines and plants
Siemens ST 80 / ST PC · 2013
4/31
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Recipes
■ Overview
■ Benefits
• Generation and management of machine parameters and
production data on the basis of data records, and exchange
with the automation device, e.g. with the machine.
• Clear tabular representation of the data elements with the aid
of a configurable screen object, or depiction in technological
relationships across several process screens.
• Simple operator guidance through standard functions.
• Export/import of data records for further processing with other
tools (e.g. MS Excel)
■ Function
4
• Option for SIMATIC WinCC Runtime Advanced and
WinCC Runtime Professional for managing data records in
recipes that contain related machine or production data
• The data in a data set can be transferred, for example, from
the control unit to the PLC to switch production to a different
product variant
• Licensing:
- SIMATIC Panels / Multi Panels / Comfort Panels:
No license is required.
- WinCC Runtime Advanced:
One license is required per operator station
- WinCC Runtime Professional:
A license is only required on the server
(or single-user system).
• Input of data records (e.g. operating parameters of a
machine, production data for a plastics machine) on the
HMI device as well as their storage and transfer to the control
• Display or entry of data records via a configurable screen
object or via several process screens distributed within the
project
• The data record elements are coupled with the process via a
direct tag connection
• Transmission of data records from or to the controller
• Powerful interfaces enable a synchronized data exchange
with the controller
• Storage of data records on local data carriers or on remote
data servers via networks
• Logging of data records, e.g. as batch report/shift report
• User-friendly and flexible management of data records by
powerful standard functions
The recipes and the associated data records are created using
a separate, user-friendly WinCC Engineering editor and data is
pre-assigned to them. A configurable table object is used for
displaying the data at runtime. Furthermore, the individual data
record elements can also be displayed directly based on
standard input/output fields across several process screens.
In this way, the data in technological views can be presented
clearly to the operator.
Import and export functions support the importing and exporting
of data via external applications (e.g. MS Excel).
4/32
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Recipes
■ Technical specifications
■ Ordering data
Order No.
WinCC Recipes
for Runtime Advanced
SIMATIC WinCC Recipes for
Runtime Advanced 1)
The values specified are maximum
values
Single license, license key
only on USB stick
Number of recipes
999
SIMATIC WinCC Recipes +
Logging for Runtime Advanced 1)
Number of elements per recipe 1)
2 000
Single license, license key
only on USB stick
User data length in KB per data
record
256
SIMATIC WinCC Recipes for
Runtime Professional 1)
Number of data records per recipe
5 000
Single license, license key
only on USB stick
1)
When using arrays, each array element represents a recipe element
WinCC Recipes
for Runtime Professional
The values specified are maximum
values
Number of recipes
Unlimited 2)
Number of elements per recipe 2)
500 3)
User data length in KB per data
record
3 000 3)
Number of data records per recipe
5 000 2)
6AV2107-0JA00-0BB0
6AV2107-0HA00-0BB0
6AV2107-0JB00-0BB0
Online software delivery (OSD) 2)
WinCC Recipes for
Runtime Advanced 1)
6AV2107-0JA00-0BH0
Single license, license key
download only; E-mail address
required for the delivery
WinCC Recipes for
Runtime Professional 1)
6AV2107-0JB00-0BH0
Single license, license key
download only; E-mail address
required for the delivery
4
2)
Limited by system resources.
1)
3)
The sum of the number of recipe elements and number of data records
must not exceed a value of 320,000.
One license is required for each operator console. A license is not required
for the engineering system for configuring the runtime option.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Siemens ST 80 / ST PC · 2013
4/33
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Logging
■ Overview
■ Benefits
• Alarm and process value logs enable predictive diagnostics,
which avoids downtimes
• Early detection of danger and fault conditions
• Increase of the product quality and the productivity thanks to
regular analysis of the alarm and process value logs
■ Application
•
•
•
•
•
Transfer of the logs for evaluation and long-term archiving
Detection of recurring error states
Optimization of maintenance cycles
Ensuring the quality standard
Quality assurance and checking the utilization of production
sequences
• Documentation of process sequences
4
• Option for SIMATIC WinCC Runtime Advanced and WinCC
Runtime Professional for logging process values and alarms
• Logging of process values and alarms supports the acquisition and processing of process data from an industrial plant
or machine. Evaluation of the logged process data provides
information about the operating states of the plant or machine
• Licensing:
- SIMATIC Panels / Multi Panels / Comfort Panels:
No license is required.
- WinCC Runtime Advanced:
One license is required per operator station
- WinCC Runtime Professional:
500 Logging Tags are already included in the basic package
The number of Logging Tags can be increased by means of
additional licenses
4/34
Siemens ST 80 / ST PC · 2013
■ Function
• Time-controlled as well as manual or process-controlled
swapping out of process data and alarms for long-term
archiving
• During runtime, swapped out data are read in and selectively
analyzed using WinCC Runtime Professional
- Presentation and evaluation of archived process data based
on a configurable trend display. Reading of the values is
facilitated by a read line.
- Presentation and evaluation of archived alarms based on a
configurable alarm view.
- User-friendly navigation in the logs
• External evaluation of the logs using MS standard tools
• Various log types are supported: sequence and circular logs
• Logging of process values and alarms on external, Windowssupported storage media
- SIMATIC Panels and WinCC Runtime Advanced:
CSV files, RDB files, Microsoft SQL Server via ODBC
- WinCC Runtime Professional: Microsoft SQL Server 2005
• Powerful standard functions permit user-friendly and flexible
utilization of the logs
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Logging
■ Technical specifications
■ Ordering data
Order No.
WinCC Logging
for Runtime Advanced
SIMATIC WinCC Logging
for Runtime Advanced 1)
The values specified are maximum
values
Single license, license key
only on USB stick
Number of logs
100
Archivable data
Process values, alarms
SIMATIC WinCC Recipes +
Logging for Runtime Advanced 1)
Cyclical trigger for archiving
process values (variables)
1s
Max. number of entries per log
(incl. sequence log)
500 000 1)
SIMATIC WinCC Logging
for Runtime Professional
1500 Logging Tags
Log types
Circular logs,
sequence logs (max. 400 per log)
Single license, license key
only on USB stick
Data storage format
CSV (Comma Separated Variable),
RDB (Runtime Data Base),
Microsoft SQL database (database
not included in scope of delivery)
SIMATIC WinCC Logging
for Runtime Professional
5000 Logging Tags
1)
6AV2107-0GA00-0BB0
Single license per option,
license key only on USB stick
6AV2107-0GB00-0BB0
6AV2107-0GD00-0BB0
Single license, license key
only on USB stick
Dependent on memory medium used
WinCC Logging
for Runtime Professional
The values specified are maximum
values
WinCC Logging for Runtime
Professional Powerpack
1500 -> 5000 Logging Tags
6AV2107-2GD00-0BD0
Single license, license key
only on USB stick
Number of logs
per single-user station/server
100
Archivable data
Process values, alarms
WinCC Logging Upgrade for
SIMATIC WinCC Archives V7.0
(10 licenses)
Measured values per second, max.
Server/single-user station:
5 000 per sec.
Single license per option,
license key only on USB stick
Log tags per single-user station/
server
80 000 2)
Online software delivery (OSD) 2)
Log types
Circular log with and without
long-term logging
Data storage format
Microsoft SQL 2005 database
2)
6AV2107-0HA00-0BB0
Dependent on the Logging Powerpack used for the log tags.
500 log tags are contained in the basis version.
WinCC Logging for
Runtime Advanced 1)
6AV2107-4GX00-0BF0
4
6AV2107-0GA00-0BH0
Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional - 1500 Logging Tags
6AV2107-0GB00-0BH0
Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional - 5000 Logging Tags
6AV2107-0GD00-0BH0
Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional Powerpack
1500 -> 5000 Logging Tags
6AV2107-2GD00-0BJ0
Single license,
license key download only
e-mail address required for
the delivery
1)
One license is required for each operator console. A license is not required
for the engineering system for configuring the runtime option.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Siemens ST 80 / ST PC · 2013
4/35
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Audit
■ Overview
■ Technical specifications
WinCC Audit
Storage location for Audit Trail when
used on the Panel
Plug-in Flash memory card or
via Ethernet in the higher-level PC
Storage location for Audit Trail when
using WinCC Runtime Advanced
Local hard disk or
via Ethernet in the higher-level PC
Execution platform
SIMATIC Panels
Mobile Panel 277, TP/OP 277
SIMATIC Multi Panels
MP 277, MP 377
SIMATIC Comfort Panels
all
PC systems
SIMATIC WinCC Runtime Advanced
■ Ordering data
4
• Option for SIMATIC WinCC Runtime Advanced as well as
SIMATIC Panels for recording operations in an audit trail, and
electronic signature
• The audit trail is furnished with a security mechanism that
displays subsequent manipulations.
• A user-friendly configuration function, which is included as
standard in WinCC, is used to define the following:
- Which user actions should be recorded in the audit trail
during runtime
- Which important operator actions during execution time
require electronic signature/comments
• Available for the following SIMATIC HMI systems:
- Comfort Panels
- Mobile Panels
- TP/OP 277
- MP 277
- MP 377
- WinCC Runtime Advanced
• Licensing:
- A license is required for every operator control unit
(panel or PC).
■ Benefits
• Audit supports the user in meeting special quality requirements, e.g.
- Production plant requiring validation according to
21 CFR Part 11 FDA 1)
- In respect of traceability according to EU 175/2002 2)
• The entries in the audit trail are uniquely assigned to users.
This means that responsibilities are clearly identifiable.
• The audit trail, stored as a CSV file 3), can be checked via a
security mechanism to find out if subsequent changes have
been made.
• For particularly important user actions, e.g., starting
production or loading new recipes, electronic signatures and
comments can be configured and then called up and logged
during runtime.
1)
The FDA (Food and Drug Administration) is the American public health
body
2)
21 CFR Part 11- law on plant validation
3)
CSV Comma Separated Values
4/36
Siemens ST 80 / ST PC · 2013
SIMATIC WinCC Audit
for SIMATIC Panels
Order No.
6AV2107-0RP00-0BB0
Single license,
license key only on USB stick
SIMATIC WinCC Audit
for Runtime Advanced
6AV2107-0RA00-0BB0
Single license,
license key only on USB stick
Online software delivery (OSD) 1)
WinCC Audit for SIMATIC Panels
6AV2107-0RP00-0BH0
Single license,
license key download only
E-mail address required for the
delivery
WinCC Audit
for Runtime Advanced
6AV2107-0RA00-0BH0
Single license,
license key download only
E-mail address required for the
delivery
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
SIMATIC Logon
■ Overview
■ Design
SIMATIC Logon for Panels and WinCC Runtime Advanced
SIMATIC Logon and SIMATIC Logon Remote Access are
installed on a central station.
• Option for connecting SIMATIC Panels and PCs with
SIMATIC WinCC Runtime Advanced as well as WinCC
Runtime Professional to a central user administration.
• Creates user administration on a central computer to which
one or more panels or WinCC stations can be connected over
Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
SIMATIC Logon for Panels and WinCC Runtime Advanced
• All users of the SIMATIC Panels or WinCC Runtime Advanced
stations can be managed plant-wide from a central location
• Supports the user in combination with the Audit option in
meeting requirements in accordance with FDA 21 CFR Part 11
and EU178.
• Licensing:
SIMATIC Logon (basic license) and SIMATIC Logon Remote
Access (3-pack license) for the connection of 3 panels or
WinCC Runtime Advanced stations to a central user administration. Additional stations can be connected by using further
SIMATIC Logon Remote Access licenses (3-pack/10-pack).
SIMATIC Logon for WinCC Runtime Professional
• All users of WinCC Runtime Professional can be managed
plant-wide from a central location.
• The central user management with SL utilizes Windows
mechanisms and must be installed on all participating
WinCC Runtime Professional stations.
• Licensing:
SIMATIC Logon (basic license) is included in the basic
package of WinCC Runtime Professional
■ Benefits
• Centralized configuration of all access authorizations of a
distributed system avoids unnecessary travel times. Timeconsuming multiple configurations for each individual local
station become unnecessary. Accordingly, users can be
easily configured from a central location.
• All access data apply throughout the plant on every
connected station. Additional access data on local
subsystems is no longer necessary.
The following Runtime stations are connected to the central
station via the Ethernet network:
• PCs with WinCC Runtime Advanced
• SIMATIC Panels from the 177 series or higher
(with Ethernet interface)
• SIMATIC Mobile Panels from the 177 series or higher
(with Ethernet interface)
• SIMATIC Multi Panels
• SIMATIC Comfort Panels
SIMATIC Logon for WinCC Runtime Professional
The SIMATIC Logon can be used for the central user
management of several WinCC Runtime Professional stations.
Operation in a Windows Workgroup or even in a domain is
possible.
■ Function
Users receive a unique user ID, user name and password.
This information is encrypted and stored at a central point
(for SIMATIC Logon in the Windows user management).
Functions such as changing the password, automatic log-off
after a predefined time and lockout after several incorrect entries
of a password ensure maximum security of operation.
In addition, SIMATIC Logon allows setting up new users online,
plant-wide and across applications, or blocking of existing
users. SIMATIC Logon also supports electronic signature.
■ Ordering data
Order No.
SIMATIC Logon V1.5
6ES7658-7BX51-0YA0
Basic license 1)
For panels or WinCC Runtime
Advanced stations, the corresponding number of additional SIMATIC
Logon Remote Access licenses is
required.
No SIMATIC Logon Remote Access
licenses are required for WinCC
Runtime Professional
SIMATIC Logon Upgrade to V1.5
6ES7658-7BX51-0YE0
SIMATIC Logon Remote Access
(3 clients)
6ES7658-7BA00-2YB0
Remote Access for 3 clients;
Single License for 3 SIMATIC Logon
Remote Access clients;
the number of licensed clients is
determined from the sum of the
installed SIMATIC Logon Remote
Access licenses.
SIMATIC Logon Remote Access
(10 clients)
6ES7658-7BB00-2YB0
Remote Access for 10 clients;
Single License for 10 SIMATIC
Logon Remote Access clients;
the number of licensed clients is
determined from the sum of the
installed SIMATIC Logon Remote
Access licenses.
1)
SIMATIC Logon V1.5 included in scope of supply of WinCC Runtime
Professional.
Siemens ST 80 / ST PC · 2013
4/37
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC [email protected]
■ Overview
[email protected]
Master Station
[email protected]
Operator Station 1
Operator Station 2
Operator Station n
G_ST80_XX_00071
...
Industrial Ethernet
4
• Option for SIMATIC WinCC Runtime Advanced plus
SIMATIC Panels for communication between various
SIMATIC HMI systems.
• Available for the following SIMATIC HMI systems:
- Comfort Panels
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 277, OP 277
- MP 177, MP 277, MP 377
- WinCC Runtime Advanced
• A SIMATIC HMI system can be used to control or monitor
another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with
head end or control room
• Local operation, visualization and data processing are as
possible as plant-wide access to information. Integrated information flows ensure an overview of the status of all processes.
• Licensing:
The "SIMATIC WinCC [email protected] for Panel" or
"SIMATIC WinCC [email protected] for WinCC Runtime Advanced"
license must be installed on the server HMI device. A license
is not required for the engineering system for configuring the
runtime option.
Note:
When accessing the operator stations via the [email protected]
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
■ Benefits
• Flexible solution for remote access to HMI systems
• Quick elimination of malfunctions or downtimes – thus
increasing the productivity – through global access to
machines/plants by the service and maintenance personnel.
4/38
Siemens ST 80 / ST PC · 2013
• Avoidance of on-site service calls.
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC [email protected]
■ Application
• Operator control and monitoring of machines covering large
areas with several operator stations by one operator.
• Operator control and monitoring of machine-level HMI
systems from one central station (e.g. head-end station of a
production line or from a control room)
[email protected]
Master Station
• Remote maintenance and servicing of machines/plants over
the Internet/Intranet
[email protected]
Operator Station 1
Operator Station 2
Operator Station n
G_ST80_XX_00071
...
Industrial Ethernet
Application of the [email protected] concept: Coordinated operation of several operator stations
Master Control Station
[email protected] display
Industrial Ethernet
Server 1
[email protected]
Server 2
[email protected]
Server 3
Server 4
[email protected]
[email protected]
G_ST80_XX_00072
PROFIBUS
Use of the [email protected] display: Operator control and monitoring of machine-level HMI systems from one central station
Siemens ST 80 / ST PC · 2013
4/39
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC [email protected]
■ Application (continued)
■ Function
Coordinated operation of several operator stations:
• The HMI application and communication with the controller
takes place via the master station. "[email protected]" can be
activated from here in the case of machines/plants with larger
dimensions which require a larger number of HMI devices.
The [email protected] are then provided with access to the master
station and thus to the process. Access procedures guarantee
that only one operator system can actively access the process
at any given time.
• Embedded in process screens, a configurable screen object
([email protected] display) represents the screen of the relevant
HMI system ([email protected])
• Powerful standard functions permit user-friendly and flexible
operation of the display
{jwVpw
pzkuVkzs
t–‹Œ”Vy–œ›Œ™
l•Ž•ŒŒ™•ŽGz›ˆ›–•
wjVwn
p•›Œ™•Œ›
pzkuVkzs
t–‹Œ”Vy–œ›Œ™
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
jˆšŒGYaG
v—Œ™ˆ›–™GŠ–•›™–“Gˆ•‹G”–•›–™•Ž
œš•ŽG›ŒGp•›Œ™•Œ›Vp•›™ˆ•Œ›Gž›
ˆŠŠŒššG›–G›ŒGŠ–”—“Œ›ŒG‹ŒŠŒb
š–›’Œ šGˆ•‹Gœ•Š›–•G’Œ š
Engineering Station
PC/PG
jˆšŒGXaG
v—Œ™ˆ›–™GŠ–•›™–“Gˆ•‹G”–•›–™•Ž
œš•ŽG›ŒGtŠ™–š–›Gp•›Œ™•Œ›G
lŸ—“–™Œ™
p•‹œš›™ˆ“Gl›Œ™•Œ›
wyvmpi|z
n†z{_W††WWW^]
4
G_ST80_XX_00073
p•‹œš›™ˆ“G
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
4/40
Siemens ST 80 / ST PC · 2013
Remote control of an operating station:
• The HMI application and communication with the controller
takes place via the HMI system. Using the [email protected], the
HMI systems in the machines/systems can be serviced
remotely. An access process ensures that only one operator
(either locally at the machine or remotely via Internet Explorer)
can actively access the process at one time.
• Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for
accessing an HMI system.
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC [email protected]
■ Technical specifications
■ Ordering data
WinCC [email protected]
The values specified are maximum
values
Execution platform
SIMATIC Comfort Panels
all
SIMATIC Panels
Mobile Panel 177 PN,
Mobile Panel 277,
TP/OP 177B PN/DP,
TP/OP 277
SIMATIC Multi Panels
MP 177,
MP 277,
MP 377
PC systems
SIMATIC WinCC Runtime Advanced
Number of [email protected] that
can simultaneously connect to
a [email protected]
Comfort Panel
as [email protected]
2 clients for 4" devices
3 clients for 7", 9", 12" and 15"
devices
2 clients for 19" devices
1 client for 22" devices
Mobile Panel 177 PN,
TP/OP 177B PN/DP,
MP 177 as [email protected]
2 clients
Mobile Panel 277,
TP/OP 277,
MP 277 as [email protected]
3 clients for 6" devices
2 clients for 8" and 10" devices
MP 377 as [email protected]
3 clients for 12" devices
2 clients for 15" devices
1 client for 19" devices
WinCC Runtime Advanced as
[email protected]
5 clients
Order No.
WinCC [email protected]
for SIMATIC Panels 1)
Single license, license key
only on USB stick
6AV2107-0CP00-0BB0
WinCC [email protected]
for Runtime Advanced 1)
Single license, license key only on
USB stick
6AV2107-0CA00-0BB0
Online software delivery (OSD) 2)
WinCC [email protected]
for SIMATIC Panels 1)
Single license, license key
download only
E-mail address required for
the delivery
6AV2107-0CP00-0BH0
WinCC [email protected]
for Runtime Advanced 1)
Single license, license key
download only
E-mail address required for
the delivery
6AV2107-0CA00-0BH0
4
1)
The license must be installed on the [email protected] HMI device. A license is
not required for the engineering system for configuring the runtime option.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Siemens ST 80 / ST PC · 2013
4/41
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Server / WinCC Client
■ Overview
WinCC
Client
WinCC
Client
WinCC
Client
TCP/IP
SIMATIC S7-1200
SIMATIC S7-300
SIMATIC S7-400
4
• Option for SIMATIC WinCC Runtime Professional, which
permits the configuration of a powerful client/server system
• One of the following operating systems must be available to
install the option on the server: Windows Server 2003,
Windows Server 2003 R2, Windows Server 2008 or
Windows XP Professional. When using Windows XP
Professional, max. 3 clients can be connected.
• A number of coordinated HMI stations can be operated in a
single group with networked automation systems
4/42
Siemens ST 80 / ST PC · 2013
n†z{_W††WW[^Y
Process bus
• Client/server solution: One server can supply up to
32 connected clients with process and archive data, alarms,
screens and reports
- Requirement: Network connection (TCP/IP) between the
server PC and the connected clients
• Licensing:
- A WinCC Runtime Professional license on the server with the
appropriate number of PowerTags and the "WinCC Server for
RT Professional" license.
- The "WinCC Client for RT Professional" license on the clients.
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Server / WinCC Client
■ Benefits
• Integrated scalability from the single-user system to the client/
server solution
• Considerably expanded quantity structure, relieves the load
on the individual servers, and thus better performance
through the distribution of the overall application or of the
tasks among several servers
■ Application
In a complex plant, WinCC Runtime Professional can be
configured as a distributed system depending on the requirements:
• Functional distribution (e.g. alarm server, log server, etc.), or
• Distribution corresponding to the physical plant structure
(e.g. body-in-white, paint shop, etc.).
■ Function
All process data of a WinCC project is stored in different Runtime
databases, e.g. alarms, trend values, etc. These Runtime
databases are located on a central computer, the WinCC Server,
instead on each HMI device. The operator stations, i.e. the
WinCC Clients, then access the WinCC Server.
WinCC Clients and WinCC Server are independent systems.
You can also connect WinCC Clients subsequently. Alternatively,
you can activate and deactivate a project from a WinCC Client.
■ Ordering data
Order No.
SIMATIC WinCC server
for Runtime Professional
Single license, license key
only on USB stick
6AV2107-0EB00-0BB0
SIMATIC WinCC Client
for Runtime Professional V12
Single license, license key on USB
stick, software and documentation
on DVD
6AV2107-0DB02-0AA0
SIMATIC WinCC Client for
Runtime Professional ASIA V12
Single license, license key on USB
stick, software and documentation
on DVD
6AV2107-0DB12-0AA0
Online software delivery (OSD) 1)
SIMATIC WinCC server
for Runtime Professional
Single license, license key
download only,
e-mail address required for the
delivery
6AV2107-0EB00-0BH0
SIMATIC WinCC Client
for Runtime Professional V12
Single license, software an
d license key download.
E-mail address required for
the delivery
6AV2107-4DB02-0AK0
4
A license is not required for the engineering system for
configuring the runtime option.
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Siemens ST 80 / ST PC · 2013
4/43
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator
■ Overview
~•jj
zjhkhGŠ“Œ•›š
~•jj
~Œ‰GŠ“Œ•›
~•jj
kˆ›ˆt–•›–™
shu
~•jjGšŒ™Œ™
RG~Œ‰uˆŽˆ›–™V
kˆ›ˆt–•›–™
šŒ™Œ™
wyvmpul{
wyvmpi|z
n†z{_W††WW\\]
4
• Option for SIMATIC WinCC Runtime Professional for operating
and monitoring plants over the Internet, company Intranet or
LAN.
• Configuration from:
- A web server with SIMATIC WinCC Runtime Professional as
single-user or server version and a web client that permits
operator control and monitoring of a current WinCC Runtime
Professional project using the Internet Explorer.
• Licensing:
- A license is required for using the Web server.
- Server-based licenses are available for access to the web
server by 3, 10, 25 or 50 clients.
- Client-based licenses are available for guaranteed access to
the web server (Diagnostics Client)
4/44
Siemens ST 80 / ST PC · 2013
Note:
When accessing the operator stations via the
WinCC WebNavigator option, suitable protective measures
(including IT security such as network segmentation) should be
taken in order to ensure safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator
■ Benefits
• Operator control and monitoring across long distances and
on different platforms (PC, local panel, mobile PDA)
• Large configurations with up to 50 operator stations
• Fast update rates due to event-driven communication
• Optimally tailored clients for operating and monitoring,
analysis, service and diagnostics
• Acceptance of configuration data for the web, generally
without changes
• Minimum maintenance costs due to central software
administration
• High security standards and availability
- Support for commonly used security mechanisms
(routers, firewalls, proxy servers)
- WinCC access authorizations and user administration
• Support of Microsoft Internet Explorer, including "tabbed
browsing". A new license is not required for separate tabs.
• With the WinCC Web Viewer (WinCC Viewer RT), the process
screens can be displayed on the web client independently of
the Internet Explorer. Settings for the client are made on the
client itself. The WinCC Web Viewer can also be used in
conjunction with the MS Terminal Service.
• The SIMATIC WinCC WebNavigator can also be operated in
"view only" mode and is thus used as tool for monitoring and
navigating using Internet Explorer or WinCC Web Viewer
(WinCC Viewer RT).
• Web server logins and logouts are recorded in the alarm and
audit log.
• There is a gadget available for the Windows 7 operating
system in which selected WinCC process screens can be
displayed. No additional WebNavigator license is required for
the gadget. The WebNavigator server can be selected directly
via the gadget.
• Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
Highlights:
• Multiple Web servers can be accessed from a single Web
client
• User-friendly services and tools for distributing customized
objects (controls, files) to web clients can be supplied for use
as an integration platform. These components can then also
be integrated into cross-web/server navigation.
• Both Internet Explorer and the supplied, browser-independent
WinCC Web Viewer (WinCC Viewer RT) can be used as a front
end
• Access to WebNavigator Server of the WinCC V7.x series.
■ Application
In addition to the typical use of the WebNavigator in WANs
(Wide Area Networks), the WebNavigator can also be used to
implement especially low-cost applications. This especially
includes applications that have a pronounced distributed
structure (water/wastewater, oil and gas), or in which access to
process information is only sporadic (building management).
The WebNavigator also permits vertical integration, i.e. a
networked IT landscape with integrated data flow between the
planning and operating level of a company. Only a standard
browser is required for direct access to current process information.
In addition to the standard WebNavigator licensing, there is the
"Diagnostics Client" with identical functionality but different
licensing. It is especially suitable for the following applications:
• Remote diagnostics/operation of several unmanned
WinCC Runtime Professional stations
• Central control rooms that monitor several web servers via one
user interface
• Maintenance personnel who require guaranteed access to
the server at any time, regardless of the number of users
already logged on to the server. On the server side, only one
WebNavigator Diagnostics Server license or, alternatively, one
Standard WebNavigator license is required.
4
■ Design
Licenses for the WebNavigator
The WebNavigator Client software can be installed as many
times as required without the need for a license.
• Server-based licensing
- A license is required for using the WebNavigator Server.
- Licenses are available for simultaneous access to the Web
server by 3, 10, 25 or 50 clients.
• Diagnostics client licensing
- For cost-optimized access by one or a small number of
WebNavigator clients to numerous Web servers (e.g. for
diagnostic purposes). This client license provides
guaranteed access to Web servers at any time. In respect of
function there is no difference compared with regular
WebNavigator clients and the two can be mixed.
WebNavigator Clients are capable of accessing several different
Web Servers.
Thin client solutions
The WebNavigator can also run under Windows Server 2003 or
Windows Server 2008 terminal services. A Windows Server 2003
or Windows Server 2008 (or higher) operating system is
required. This makes it possible to connect SIMATIC Thin Clients
as visualization stations to WinCC Runtime Professional, for
example.
For this purpose, the Windows terminal services must be
installed on the PC on which the Web Client is installed.
A Windows Server 2003 or Windows Server 2008 (or higher)
operating system is required. Up to 25 thin clients can be
connected to one terminal server.
Applications:
• Mobile devices
• Handhelds
• Rugged on-site visualizations
Siemens ST 80 / ST PC · 2013
4/45
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator
■ Design (continued)
Hybrid configuration
System requirements: WinCC WebNavigator – Server V12
• Windows 7 SP1 (32- and 64-bit) Business, Enterprise and
Ultimate (max. 3 Clients)
• Windows XP Professional Service Pack 3 (max. 3 clients)
• Windows Server 2003 SP2
• Windows Server 2008 SP2 32-bit
• Windows Server 2008 R2 SP1 64-bit
• Internet Explorer V7.0, V8.0, V9.0
• Microsoft SQL Server 2008 R2 SP1 32-bit
(included in the WinCC product delivery)
• WinCC Basic System V12
System requirements: WinCC WebNavigator – Client V12
• Internet Explorer 7, IE 8, IE9
4
System requirements: WinCC WebNavigator – Server V11
• Windows 7 (32-bit) Business, Enterprise and Ultimate
(max. 3 clients)
• Windows XP Professional Service Pack 2 (max. 3 clients)
• Windows Server 2003 SP2 and Windows Server R2 SP2
• Windows Server 2008
• Internet Explorer 7 as well as Internet Explorer 8
• Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)
• WinCC Runtime Professional V11
System requirements: WinCC WebNavigator – Client V11
• Internet Explorer 7 as well as Internet Explorer 8
■ Function
WinCC Professional makes setting up and configuring a
WebNavigator server very easy. WinCC process screens to be
visualized via the Internet are created as usual in WinCC Professional and the web access is activated via a process screen
option. To display WinCC process screens on the web client, the
Microsoft Internet Explorer or browser is used independent of
the supplied WinCC Web Viewer (WinCC Viewer RT).
The operator on the Web Client is integrated in the central
WinCC user administration and can operate and monitor the
system according to the configured access rights.
The WebNavigator supports all standard security mechanisms
that can be used for applications on the Internet, e.g. routers,
firewalls and proxy servers.
■ Ordering data
Order No.
SIMATIC WinCC WebNavigator
for Runtime Professional
Single license, license key
only on USB stick
• 3 clients, runtime software
• 10 clients
• 25 clients
• 50 clients
• 100 clients
• 150 clients
6AV2107-0KD00-0BB0
6AV2107-0KF00-0BB0
6AV2107-0KH00-0BB0
6AV2107-0KK00-0BB0
6AV2107-0KM00-0BB0
6AV2107-0KP00-0BB0
SIMATIC WinCC WebNavigator
for Runtime Professional
Powerpacks
Single license, license key
only on USB stick
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
• From 50 to 100 clients
• From 100 to 150 clients
6AV2107-2KF00-0BD0
6AV2107-2KH00-0BD0
6AV2107-2KK00-0BD0
6AV2107-2KM00-0BD0
6AV2107-2KP00-0BD0
SIMATIC WinCC WebNavigator
Diagnostics Server/Client
Single license, license key only on
USB stick
• WinCC WebDiagnostics Server
for Runtime Professional, Runtime
software
• WinCC WebDiagnostics Client for
Runtime Professional, Runtime
software
6AV2107-0KR00-0BB0
6AV2107-0KT00-0BB0
New type of delivery
Online software delivery (OSD) 1)
WinCC WebNavigator
for Runtime Professional
Single license, license key
download only,
e-mail address required for
the delivery
• 3 clients
• 10 clients
• 25 clients
• 50 clients
• 100 clients
• 150 clients
6AV2107-0KD00-0BH0
6AV2107-0KF00-0BH0
6AV2107-0KH00-0BH0
6AV2107-0KK00-0BH0
6AV2107-0KM00-0BH0
6AV2107-0KP00-0BH0
WinCC WebNavigator for
Runtime Professional
Powerpacks
Single license, license key
download only,
e-mail address required for
the delivery
• 3 to 10 clients
• 10 to 25 clients
• 25 to 50 clients
• 50 to 100 clients
• 100 to 150 clients
6AV2107-2KF00-0BJ0
6AV2107-2KH00-0BJ0
6AV2107-2KK00-0BJ0
6AV2107-2KM00-0BJ0
6AV2107-2KP00-0BJ0
WinCC WebNavigator
Diagnostics Server/Client
Single license, license key
download only,
e-mail address required for
the delivery
• WinCC Web Diagnostics Server
for Runtime Professional
• WinCC Web Diagnostics Client
for Runtime Professional
6AV2107-0KR00-0BH0
6AV2107-0KT00-0BH0
A license is not required for the engineering system for configuring the
runtime option.
1)
4/46
Siemens ST 80 / ST PC · 2013
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor
■ Overview
~•jj
zjhkhGŠ“Œ•›š
~•jj
~Œ‰GŠ“Œ•›
~•jj
kˆ›ˆt–•›–™
shu
~•jjGšŒ™Œ™
RG~Œ‰uˆŽˆ›–™V
kˆ›ˆt–•›–™
šŒ™Œ™
wyvmpul{
n†z{_W††WW\\]
wyvmpi|z
• The WinCC DataMonitor is used for displaying and evaluating
current process states and historical data on office PCs using
standard tools such as Microsoft Internet Explorer or Microsoft
Excel. In doing so, the DataMonitor client is supplied by a Web
server with current and historic process data and alarms. All
staff ranging from machine operators to corporate managers
can use the DataMonitor to obtain information.
• DataMonitor is a suite of Internet-capable tools:
- Process Builder
Tool exclusively for monitoring and navigating via
WinCC Runtime Professional screens using Internet Explorer
(view only) or the WinCC Web Viewer (WinCCViewerRT)
- Excel Workbooks
Logging tool that integrates WinCC Runtime Professional
Archive and online values into Microsoft Excel and supports
online analysis
- Published Reports
Event or time-driven implementation of Excel or PDF reports
for the output of process data and analysis results
- Webcenter
Individual configuration of Internet pages and summary of
information within a portal with reference to WinCC Runtime
Professional applications
- Trends and Alarms
(tables and graphs) are preconfigured Webcenter pages
• DataMonitor does not require manual client installation
because it loads the required components from the web
server.
• There is no installation required on the client for the Webcenter
and Trends and Alarms functions.
• Licensing:
- Licenses for access by 1, 3, 10, 25, or 50 DataMonitor clients
are available.
- Any combination of DataMonitor and WebNavigator licenses
can be used in an application.
Note:
When accessing the operator stations via the
WinCC DataMonitor option, suitable protective measures
(including IT security such as network segmentation) should
be taken in order to ensure safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
Siemens ST 80 / ST PC · 2013
4/47
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor
■ Benefits
■ Function
• Information can be compiled online individually during
runtime via the Internet/Intranet.
• Efficiently monitor and analyze production lines.
- Display and evaluation of current process states and
historical data on remote office PCs with standard tools such
as Microsoft Internet Explorer or Excel.
- Easy access to production data via the Intranet or Internet
- Quick ascertainment of the production situation
• Easily collect and distribute information.
- Automated report creation
- No additional configuration effort through direct use of
screens from the WinCC project
- No training required for standard products
- Easy exchange of configuration data
• Substantiate decisions with reports.
- Evaluation via ready-made templates for special analyses
of the business processes (e.g. reports, statistics)
- Display bottlenecks transparently
- Individual views for user and situation
- Relative and absolute timeframe for information generation
• View production status anywhere and anytime.
- Individual views of information in production
- View the process and system operation
- Historical data can be compiled online individually
4
Highlights:
• With the Webcenter function, WinCC Runtime Professional
archive tags can be accessed without changing the configuration system.
• Dedicated Internet pages can be created for displaying data
with the Webcenter. For this purpose, the following tools,
which can be integrated in the Internet sites, are available.
- Bar chart, pie chart, trend curve display
- Process value table and statistics functions for the process
values
- Alarms, hit list for alarms
- Message text display for individual message texts, message
display, selection list of created reports,
- Links to internal and external pages
- Display of graphics in jpg format
- Representation of the WinCC Runtime Professional process
screens
• The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
• Reports generated with Excel or with WinCC Professional can
be made available on the DataMonitor server or e-mailed
automatically to the relevant group of people based on time
intervals or triggered by events.
• Connections to WinCC Runtime Professional and to swapped
out archives can be established
• Support of Microsoft Internet Explorer version, including
"tabbed browsing".
4/48
Siemens ST 80 / ST PC · 2013
• All tools are fully Internet-compatible and, therefore, support
access via any type of connection (LAN, GSM, radio, modem,
Internet, etc.).
• All popular security mechanisms such as login/password,
firewalls, encryption, etc. are supported.
• Users can combine the available tools at will. Licensing only
takes into account simultaneous access to one Web server.
• For display purposes, screens from the WinCC project can be
used or special overview displays configured. Animations,
scripts, navigation and access rights remain valid.
• The WinCC DataMonitor supports a display function only.
• Company-wide Excel reports, which contain historical and
current process values, can be stored centrally for general
access (reports, statistics). However, local queries to meet
individual requirements can be compiled and executed
online. Plot and tabular representation are supported for
archive data already swapped out.
• Data can be automatically entered into created report
templates and distributed by e-mail.
• Pre-made elements make the assembly of individual web
pages easier for evaluating information.
• Individual information compilation on one or more Internet
pages with the option of branching to other detail pages.
• Pre-made Internet pages for trend and alarm display enable
an ad-hoc entry to Internet data evaluation.
• An higher-level navigation feature provides a common
framework for the various tools.
• Enhanced user management for the web center in order to
assign individual Internet pages and created reports to
specific user groups.
• A search function facilitates the management of connections
to the WinCC server.
• Swapped out archives can be connected and evaluated in the
DataMonitor WebCenter.
• Excel reports created offline can be loaded onto the
DataMonitor server and are thus made available to selected
user groups or for automatic distribution.
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor
■ Ordering data
SIMATIC WinCC DataMonitor
for Runtime Professional
Single license, license key
only on USB stick
• 1 client
• 3 clients
• 10 clients
• 25 clients
• 50 clients
SIMATIC WinCC DataMonitor
for Runtime Professional
Powerpacks
Single license, license key
only on USB stick
• From 1 to 3 Clients
• From 3 to 10 Clients
• From 10 to 25 Clients
• From 25 to 50 Clients
Order No.
Order No.
Online Software Delivery (OSD) 1)
6AV2107-0LB00-0BB0
6AV2107-0LD00-0BB0
6AV2107-0LF00-0BB0
6AV2107-0LH00-0BB0
6AV2107-0LK00-0BB0
6AV2107-2LD00-0BD0
6AV2107-2LF00-0BD0
6AV2107-2LH00-0BD0
6AV2107-2LK00-0BD0
SIMATIC WinCC DataMonitor
for Runtime Professional
Single license, license key
download only,
e-mail address required for
the delivery
• 1 client
• 3 clients
• 10 clients
• 25 clients
• 50 clients
6AV2107-0LB00-0BH0
6AV2107-0LD00-0BH0
6AV2107-0LF00-0BH0
6AV2107-0LH00-0BH0
6AV2107-0LK00-0BH0
SIMATIC WinCC DataMonitor
for Runtime Professional
Powerpacks
Single license, license key
download only,
e-mail address required for
the delivery
• From 1 to 3 clients
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
6AV2107-2LD00-0BJ0
6AV2107-2LF00-0BJ0
6AV2107-2LH00-0BJ0
6AV2107-2LK00-0BJ0
A license is not required for the engineering system for configuring the runtime option.
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Siemens ST 80 / ST PC · 2013
4/49
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC ControlDevelopment
■ Overview
■ Ordering data
You use the ControlDevelopment option to create your own
.net controls for controlling and monitoring processes. You can
use the controls in screens for WinCC Runtime Advanced and
WinCC Runtime Professional. You create the controls based
on the standard controls from Visual Studio 2005/2008
Professional .net.
Application examples:
• Special trend views
• Own recipe managements
• Complex display objects
■ Benefits
The ControlDevelopment option enables user-specific software
solutions based on a proven building block principle:
• Lower development overhead by using standards
(Visual Studio 2005/2008 Professional .net)
• Very short "Time-to-Market" resulting in a competitive
advantage
• Utilization of tried components and proven industrial functionality
4
The development of proprietary controls for WinCC Runtime
Advanced and WinCC Runtime Professional does not require
expensive, special hardware.
4/50
Siemens ST 80 / ST PC · 2013
WinCC ControlDevelopment V12
• Runtime license,
single license, software
and documentation on CD
• Runtime software,
single license, software download
(e-mail address required for the
delivery) 1)
1)
Order No.
6AV2107-0TA02-0DA8
6AV2107-0TA02-0DG8
Current information and availability regarding the new delivery package
can be found at:
http://www.siemens.com/tia-online-software-delivery
■ More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
© Siemens AG 2013
HMI Software
Software for energy management
Software for energy management
■ Overview
SIMATIC offers numerous reasons for corporate energy
management in industrial plants.
However, there is one in particular:
It makes an important contribution towards improving plant
productivity. This results in enhanced competitiveness. Energy
management with SIMATIC makes energy flows transparent in
production plants. This supports the analysis and derivation of
energy saving potential.
The result:
Permanently increased efficiency, higher productivity and an
improved cost situation.
4
Siemens ST 80 / ST PC · 2013
4/51
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC B.Data
■ Overview
SIMATIC B.Data V5.3 SP2 Energy Management System
SIMATIC B.Data is a modular, cross-sector energy management
system for industrial firms.
Energy management – Company portal
4
WinCC
Automation
field level
Energy planning and procurement
Energy controlling
Energy purchase
Purchase support
Scenario calculator
Emission
CO2 emission monitoring
Wastewater disposal
Forecast
Energy forecast
Budget planning
Energy accounting
Cost center allocation
Evaluation/invoicing
Monitoring and reporting
Connection of external systems
Facility management
ERP (e.g. SAP R/3)
Maintenance management
Energy reporting system
Analysis and reporting
Workflow system
Intranet/Internet viewer
Energy schedule
Energy purchase schedule
Specifications for Load management
Energy and material balance
KPI calculation
Production allocation
Fault/alarm management
Alarms/messages
Remote alarms (text message)
Operation and control system
Central detection
Plant visualization
Data processing and archiving
Interfaces to lower-level systems
Meters/
measuring
devices
Process
control/
building
management
systems
PLCs
Load management
Load shedding
Load control
Circuitbreakers
Mobile
data
acquisition
G_ST80_XX_00379
B.Data
■ Benefits
The option SIMATIC B.Data forms the basis of a cost-effective
energy management system for reducing energy costs and
increasing energy efficiency, and it confers the following
immediate benefits:
• It creates company-wide transparency, thanks to continuous
energy balancing and materials balancing for the power
generation systems and loads
• It allows energy costs to be allocated according to the costsby-cause principle and permits transfer to the billing system
(e.g. SAP R/3 CO)
• It generates characteristic values for well-informed suggestions for increasing the efficiency of power generation systems
and loads
4/52
Siemens ST 80 / ST PC · 2013
• It provides planning reliability thanks to production-related
load and demand forecasts
• It supports purchasing with cost-optimized energy
procurement
• It fulfills the legal obligations for monitoring and reporting on
greenhouse gas emissions (CO2 emissions)
• It relieves personnel of extra work through automatically
updating internal and external energy reports
• It supports customers in the continuous improvement of
energy efficiency (e.g. ISO 50001) by integrated project
management for energy efficiency measures
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC B.Data
■ Design
SIMATIC B.Data V5.3 SP2 Basic System
The B.Data Basic System is available in variants for 100, 500,
1 000 and 30 000 tags and comprises the following components:
• A B.Data acquisition component (WinCC, OPC, etc.)
• A B.Data Client
• B.Data Mobile
• ERP interface
• Reporting, Trender, Visu, document management, Matrix, KPI,
Profile
SIMATIC B.Data Software Update Service (SUS)
For each B.Data Basic System there is a corresponding SUS
(Software Update Service), which is dependent on the number
of tags. The SUS is valid for 1 year. The contract is automatically
extended by 1 more year unless canceled 3 months prior to
expiration.
SIMATIC B.Data V5 Expansions
The scope of B.Data can be extended by purchasing add-on
packages:
• B.Data Web Server
• B.Data Client
• B.Data Energy Forecasting and Planning
• B.Data Acquisition Component
■ Function
Acquisition and pre-processing of energy and operating
data from WinCC
• In addition to an interface to WinCC, SIMATIC B.Data also
offers the latest interface standards such as OPC, ODBC,
ASCII, or XML
• Preprocessing of energy data in a real-time calculation core
that can be freely modeled including a formula editor for
defining and configuring new calculation functions (heat
calculations for boilers, quality for cogeneration plants, etc.)
• B.Data Mobile for mobile recording of energy data including
route planning for meter reading operations
• Management and analysis of energy data
• Automatic plausibility check and generation of simulated
values
• Long-term archive with versioning, compression and consolidation functions
• Measured value editor for entering and processing energy
and operating values
• Trender for presenting up-to-date (online) and historical load
curves (trends), also for setpoint/actual value analyses
• Energy management dashboards for creating cross-company
transparency through visualization of parameters and display
of Sankey diagrams.
Siemens ST 80 / ST PC · 2013
4/53
4
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC B.Data
■ Function (continued)
Energy and material balance
Freely parameterizable balancing of the energy flows of various
media such as electricity, heat, gas, steam, and emissions
(CO2) in the B.Data Plant Explorer
• Calculation of characteristic values (KPIs, efficiency coefficients, etc.) with direct reference to production (batches,
quantities, etc.).
4
Energy accounting (costs and revenue accounting)
Calculation and allocation/assignment of energy costs to plants
and/or customers/cost units in accordance with the costs-bycause principle. The bottom up (measurement) and top down
(allocation) procedures are supported here
• Flexible modeling of the hierarchic accounting structures in
the Plant Explorer
• Tariff allocation of quantities, flexible price assessment with
tariff and price time series
• Transfer of costs/revenues to the ERP system
(e.g. SAP R/3 CO)
10%
90%
Consumption area
(e.g.: Building 1)
20%
1 ... n
75%
80%
Consumption area
(e.g.: Building 2)
25%
Counter 1
Counter 3
Counter 2
4/54
Siemens ST 80 / ST PC · 2013
Factors are based on:
• Numbers of
employees
• Area data
• Allocation formula
• etc.
100% Distribution
ensured
G_ST80_XX_00380
Accounting area
(e.g. Cost center)
Losses
Energy planning
• Generation of requirement forecasts based on productiondependent factors (production planning) and basic load
profiles (typical days)
• Generation of energy schedules for registering with the
energy suppliers. Energy reporting
• Freely parameterizable report generator for creating
balances, protocols, shift logs, bills
• Fully automated reporting with task management, e-mail
dispatch and document management
• B.Data Intranet/Internet viewer (web client) for company-wide
viewing of reports and results
• Information about discrepancies from specified parameters
through KPI warning system
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC B.Data
■ Technical specifications
■ Ordering data
SIMATIC B.Data V5.3 SP2 2)
Operating system
• Windows Server 2003 SP2 32 bit
Eng./Ger.
• Windows Server 2008 Std. Edition
32 bit Eng./Ger.
• Windows Server 2008 R2 Eng./Ger.
• Windows XP Professional SP3
32 bit Eng./Ger.
• Windows 7 Professional/Ultimate
32 bit/64 bit Eng./Ger.
• Minimum of 2 GB RAM
Interface
In addition to an interface to WinCC,
B.Data also offers the latest interface standards, such as OPC,
ODBC, ASCII and XML.
WinCC versions 1)
• SIMATIC WinCC V7.0 SP3, V7.2
• SIMATIC WinCC RT Professional
V11 SP2, V12
PCS 7 versions 3)
• SIMATIC PCS 7 V8.0 SP1
1)
If an acquisition computer is installed on a WinCC system,
these requirements must also be complied with.
2)
The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle
Database Standard Edition Embedded. For larger quantity frameworks
(as of 250 million stored measured values), you need Oracle Database
Enterprise Edition with Partitioning Option, which must be ordered
separately from Oracle.
3)
The SIMATIC B.Data system for connection to the PCS 7 must always be
installed on a separate PC.
■ More information
Further information can be found on the Internet at:
www.siemens.com/simatic-bdata
Order No.
SIMATIC B.Data V5.3 SP2
Basic System
In the basic system of B.Data, the
following components are already
included:
One B.Data acquisition component
(WinCC, OPC, etc.),
1 B.Data client, B.Data Data Mobile,
ERP interface, Reporting, Trender,
Visu, document management,
Matrix, KPI, Profile
• Basic system, 100 tags1)
• SUS for 100 tags2)
• Basic system, 500 tags1)
• SUS for 500 tags2)
• Basic system, 1 000 tags1)
• SUS for 1 000 tags2)
• Basic system, 30 000 tags1)
• SUS for 30 000 tags2)
SIMATIC B.Data V5 Powerpack
• Basic system, Powerpack 1)
Tag upgrade by 1 level
• SUS and support contract
for Powerpack 2)
SIMATIC B.Data V5.3 Trial License
6AV6372-1DF05-3AX0
6AV6372-1DF00-0AL1
6AV6372-1DF05-3BX0
6AV6372-1DF00-0BL1
6AV6372-1DF05-3CX0
6AV6372-1DF00-0CL1
6AV6372-1DF05-3DX0
6AV6372-1DF00-0DL1
6AV6372-1DF05-3XX0
6AV6372-1DF00-0XL1
6AV6372-1DF15-3AX0
Basic System, 90 days 5)
4
SIMATIC B.Data V5 Expansions 3)
The functional scope of B.Data can
be expanded with the following
packages.
SIMATIC B.Data Web Server
• incl. 3 web clients
• incl. 20 web clients
6AV6372-1DF25-2AX0
6AV6372-1DF25-2BX0
SIMATIC B.Data Client
6AV6372-1DF35-2AX0
SIMATIC B.Data
Prognosis & Planning
6AV6372-1DF45-2AX0
SIMATIC B.Data
Acquisition Component
6AV6372-1DF55-2AX0
SIMATIC B.Data upgrades
• SIMATIC B.Data 100 tags,
upgrade V5.2 -> V5.3 SP2 4)
• SIMATIC B.Data 500 tags,
upgrade V5.2 -> V5.3 SP2 4)
• SIMATIC B.Data 1 000 tags,
upgrade V5.2 -> V5.3 SP2 4)
• SIMATIC B.Data 30 000 tags,
upgrade V5.2 -> V5.3 SP2 4)
6AV6372-1DF05-3AX4
6AV6372-1DF05-3BX4
6AV6372-1DF05-3CX4
6AV6372-1DF05-3DX4
1)
The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle
Database Standard Edition Embedded. For larger quantity frameworks
(as of approx. 250 million stored measured values), you need Oracle
Database Enterprise Edition with Partitioning Option, which must be
ordered separately from Oracle.
2)
The SUS contract runs for 1 year. The contract is automatically extended
by a further year unless canceled 3 months prior to expiration.
3)
B.Data expansions can also be used with B.Data V5.2 (SP1).
4)
The upgrades are delivered without Oracle Database Standard Edition
Embedded.
5)
The trial DVD can also be used to upgrade V5.3 SP1 -> V5.3 SP2.
Siemens ST 80 / ST PC · 2013
4/55
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC powerrate
■ Overview
■ Benefits
• Identification of energy-intensive equipment and processes to
develop measures for improving energy efficiency.
• Comparison of consumption profiles for more efficient
processes.
• Optimization of the company according to energy parameters,
based on an evaluation of consumption and costs.
• Compliance with the contractually agreed power limits, thus
preventing higher power supply costs or penalty payments.
• Integration of the 7KM PAC3200/4200 measuring devices for
a clear overview of selected measured values and alarms.
• Integration of switches with an overview of the switch status
and the switching possibilities.
• Accurate assignment and comparison of the consumption
data of specific work processes or batches
■ Design
SIMATIC powerrate, as an option for WinCC / PCS 7, ensures
transparency in energy consumption from the infeed to the load.
4
SIMATIC powerrate is used in all sectors in which WinCC or
PCS 7 are deployed and energy efficiency considerations play
a major role.
Total integration into WinCC or PCS 7 means that there is no
need for a special system environment. Predefined modules and
symbols give you the assurance of building on tested product
components, with interfaces that support customized
expansion.
SIMATIC powerrate therefore provides a solution that you can
use to obtain an overview of the energy consumption of a plant
easily and cost-effectively through integration in an existing
SIMATIC SCADA system.
4/56
Siemens ST 80 / ST PC · 2013
SIMATIC powerrate comprises the following components:
• Blocks for acquiring and conditioning energy data
• Faceplates for displaying and editing energy data
• Blocks for implementing load management (calculating the
trend, monitoring the limit, releasing/inhibiting loads), batchrelated consumption recording and for integrating measuring
instruments and switches
• Additional blocks – for example, for time synchronization, data
backup, data exchange with archives
• Faceplates for displaying results and entering values
(e.g. for configuration, or manually measured values)
• Excel-based reports for allocating energy data to cost
centers, for batch-related evaluation and for determining and
displaying the load duration curve
• Exporting data to Excel
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC powerrate
■ Function
Acquiring and conditioning energy data
Using ready-to-use function blocks, energy data can be
acquired by any PROFIBUS-capable devices. The data can be
input to the function blocks in the form of counter pulses, count
values or power values. Count values can also be entered
manually.
From this data, the function block calculates the power averages
and the work values for a predefined period. This calculated
data is subsequently saved in the WinCC archive. In addition,
a final value forecast is extrapolated for the power values for
each period.
A sample function (heat calculation) that can be adapted to the
needs of the customer at any time by means of open interfaces
has been implemented for the purpose of visualizing customized
calculations.
Data from manually read counters can be entered directly into
the system and used for further analysis. Absolute numerical
values (entry of an absolute value instead of the difference from
the previous value) can also be recorded and used in further
processing.
The up-to-date, acquired energy data is displayed as power
averages/work values for each time interval (total value for the
previous interval, current value of the current interval, extrapolated value for the end of the current interval). A load trend
display enables analysis of archived energy data as well as its
representation in tables.
The archived data can be exported to Excel directly from WinCC
using the export functions. The exported energy data can also
be included in further customized processing. WinCC tools can
be used to access the data from the WinCC archive.
For this purpose, selected energy data is read from archives
(Tag Logging archive, user archives) from the WinCC Runtime
database; using Microsoft Excel the following reports can then
be generated:
• Cost center report
Here the consumption can be allocated to different cost
centers and the costs can be calculated on the basis of
predefined tariffs. The results can be output by means of
2 reports in the form of tables or diagrams.
• Load duration curve
An analysis is carried out on the basis of the archived power
averages to establish how often a certain power average has
occurred in a given period. It can be quickly detected from
this characteristic curve whether temporary power peaks exist
which can represent a possible starting point for cost savings
by means of load management.
• Batch report
This is used to allocate consumption to batches, whereby the
data can be presented in chronological order or in order of
batch name.
The generation of exports or reports can be activated manually
or automatically time-controlled (daily, weekly or monthly). Data
access and report generation can also take place via a separate
"office" PC; which enables the WinCC installation and the "office"
applications to be distributed across different PCs.
Contractually agreed power limits (in the case of electricity,
normally the 15-minute average power value) must be observed,
otherwise significantly higher supply prices or even penalty
payments may become due to the energy supply company.
The load management feature of SIMATIC powerrate carries out
cyclic trend calculations in order to issue warnings/alarms if
violation of the limit is likely and to switch off loads in accordance
with the given configuration should this be required. If a limit is
exceeded despite this, the latest load management data is
archived to enable future evaluation or analysis.
To prevent unnecessary switching operations, numerous parameters are available for adapting the load management to the
current process conditions - and all this can be done easily and
conveniently via the faceplate.
For loads that are distributed over different PLCs, SIMATIC
powerrate contains appropriate PLC-to-PLC communication
blocks which can be used to integrate these loads into the load
management system. Load management is scalable, according
to the maximum number of loads to be integrated or monitored,
for up to 10, 25, 50, 75 or 100 loads. Load management can be
performed for different media (e.g. electricity, gas) simultaneously.
A batch comprises all the units of a product that have been
produced in one production cycle, i.e. under identical conditions. Batch-related consumption recording allows accurate
recording of energy consumption for each batch. Batch-related
consumption recording is possible for five types of energy each
with up to 10 loads. Appropriate reports can be generated for
analysis of the data (see also the batch report).
If the 7KM PAC3200/PAC4200 measuring devices are
integrated, selected measured values can be displayed and
alarms (current, voltage, pulse frequency too high) can be
generated from the digital status information and displayed.
Switch integration via digital inputs/outputs (DI/DO) supports
display of the switch status (On, Off, tripped, unplugged).
With the appropriate authorization, switching is also possible via
the faceplate. Switching takes place in a 2-step operation
(switch command is issued, followed by a prompt for repeated
confirmation; the switch command is not forwarded to the switch
until confirmation has been received).
Support for the WinCC Web Navigator option also makes the
powerrate functionality possible via the web.
To avoid data loss in the event of a communication fault, the data
is stored temporarily in a circulating buffer on the S7.
Siemens ST 80 / ST PC · 2013
4/57
4
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC powerrate
■ Technical specifications
■ Ordering data
SIMATIC powerrate V4.0 SP1
Hardware requirements
SIMATIC powerrate can be used in
the PCS 7 or WinCC SCADA environments. For installation, the respective
hardware requirements of the following
products apply:
• PCS 7
• STEP 7 and WinCC SCADA
Released CPUs - SIMATIC powerrate
is released in the PCS 7 environment
for
• S7-400 CPUs supported
by PCS 7
• WinAC RTX 2010
Released CPUs - SIMATIC powerrate
is released in the WinCC SCADA
environment for
• S7-400
• S7-300
- SIMATIC S7 CPU 319-3 PN/DP
V2.5 and higher
- SIMATIC S7 CPU 317-2 PN/DP
V2.6 and higher
- SIMATIC S7 CPU 315-2 PN/DP
V3.1 and higher
• SIMATIC ET 200S IM151-8 PN/DP
CPU V3.2 and higher
• WinAC RTX 2010
You can use SIMATIC powerrate in
the PCS 7 or WinCC SCADA environments. For installation, the respective
software requirements of the following
products apply:
• PCS 7
• STEP 7 and WinCC SCADA
The library is released for the following
PCS 7 versions
• SIMATIC PCS 7 V8.0 with
Update 1 (Europe & ASIA)
• SIMATIC PCS 7 V7.1 SP3
The library is released for the following
WinCC version with the corresponding
versions of STEP 7
• SIMATIC WinCC V7. 0 SP3,
SP3 with Update 1
(Europe & ASIA)
For use with WinCC V7.0 SP3, the
following installations are required
• WinCC minimum installation
- Basic Process Control
- User archives for load management and batch-oriented energy
acquisition
• WinCC add-on
"AS-OS Engineering"
For the use of SIMATIC powerrate
V4.0, WinCC must execute in
integrated mode with STEP 7.
• SIMATIC NET
• STEP 7
powerrate Reports has been released
for the following versions
• Microsoft Excel 2003
• Microsoft Excel 2007
• Microsoft Excel 2010
4/58
Siemens ST 80 / ST PC · 2013
Order No.
6AV6372-1DE04-0AX0
Also included are
• License for user/archive
• PAC3200 function block library
for WinCC
• Block library PAC3200,
3WL/3VL for PCS 7
SIMATIC powerrate V4.0 SP1
upgrade
6AV6372-1DE04-0AX4
Upgrade V3.0 SP1 to V 4.0 SP1,
ES + OS-RT1)
SIMATIC powerrate V4.0 SP1
update
6AV6372-1DE04-0AX3
Update V4.0 to V 4.0 SP1
SIMATIC powerrate V4.0 SP1
trial license
6AV6372-1DE04-0AX7
Limited 30-day
ES + OS Runtime license
1)
Software requirements
4
SIMATIC powerrate V4.0 SP1 ES +
OS Runtime 1)
For operation on a WinCC/PCS 7 OS single-user workstation or server
and any number of automation systems. When using additional
WinCC/PCS 7 OS single-user stations/servers, one license is required
per WinCC/PCS 7 OS single-user station/server.
■ More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-powerrate
Important information on the use of SIMATIC powerrate is
available on the Internet at:
http://support.automation.siemens.com/WW/view/en/48204134/
133200
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible HMI system
■ Overview
SIMATIC WinCC flexible ES engineering software
• Family of configuration systems with WinCC flexible Micro/
Compact/Standard/Advanced for SIMATIC operator panels,
the HMI part of SIMATIC C7 as well as for the PC-based visualization software WinCC flexible Runtime
• Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
• Can be expanded by the option
"WinCC flexible /ChangeControl" for
version management and change logging
SIMATIC WinCC flexible Runtime visualization software
• Modular PC-based HMI solution for single-user systems
directly at the machine (further development of
ProTool/Pro RT)
• Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
• Basic package for visualization, reporting and logging; can be
expanded by implementing option packages
• Flexible expansion possible with VB scripts and customized
ActiveX controls created with OPP (Open Platform Program)
• Can be integrated into automation solutions based on TCP/IP
networks
• Expanded service concepts with remote operation,
diagnostics and administration over the intranet and Internet
in combination with email communication
4
Siemens ST 80 / ST PC · 2013
4/59
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES
■ Overview
■ Application
SIMATIC WinCC flexible Micro/Compact/Standard/Advanced
are engineering tools for configuring SIMATIC HMI devices, the
operating component of SIMATIC C7 devices, the SIMOTION/
SINUMERIK Panel PCs as well as the PC-based visualization
system WinCC flexible Runtime.
Depending on the selected product, various target systems can
be configured:
WinCC flexible Micro
• Micro Panels: OP 73micro, TP 170micro, TP 177micro
WinCC flexible Compact
4
• Uniform family of engineering tools for configuration
SIMATIC HMI Operator Panels, the operator control part of
SIMATIC C7 units, SIMOTION/SINUMERIK Panel PCs as well
as the PC-based visualization software WinCC flexible
Runtime.
• Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
• Current version:
- SIMATIC WinCC flexible 2008 SP3 Micro
- SIMATIC WinCC flexible 2008 SP3 Compact
- SIMATIC WinCC flexible 2008 SP3 Standard
- SIMATIC WinCC flexible 2008 SP3 Advanced
■ Benefits
WinCC flexible Standard
In addition to the target systems that are configured using
WinCC flexible Compact:
• Mobile Panels: Mobile Panel 277
• 270 series Panels: TP 270, TP 277, OP 270, OP 277
• 270 series Multi Panels: MP 270B, MP 277
• 370 series Multi Panels: MP 370, MP 377
• C7 devices: C7-636 (Touch/Key)
WinCC flexible Advanced
• The integrated configuration software reduces training,
maintenance and service overhead and protects the
customer's investments
• Minimized configuration overhead due to reuse of scalable
and dynamizable objects
• Tools for efficient and simple configuration:
- Wizard for defining the basic structure of the HMI project
- Table-based editors simplify the generation and processing
of similar types of object, e.g. for tags, texts, or alarms.
- Complex configuration tasks such as the definition of paths
of motion or the creation of the fundamental operator
prompting are simplified by means of graphical configuration.
• Comprehensive support of multi-language configurations for
worldwide use
- Selectable views for entering configuration data in several
languages
- System and user-specific text lexicons
- Export/import of language-dependent texts
4/60
In addition to the target systems that are configured using
WinCC flexible Micro:
• Basic Panels: KTP400 Basic, KTP600 Basic, KTP1000 Basic,
TP1500 Basic
• Mobile Panels: Mobile Panel 170, Mobile Panel 177
• 70 series Panels: OP 73, OP 77A, OP 77B
• 170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B,
OP 170B, OP 177B
• 170 series Multi Panels: MP 177
• C7 devices: C7-635 (Touch/Key)
Siemens ST 80 / ST PC · 2013
In addition to the target systems that are configured using
WinCC flexible Standard:
• Standard PC
• SIMATIC Panel PC: Panel PC IL 70, Panel PC IL 77,
Panel PC 477/477B, Panel PC 577/577B, Panel PC 670,
Panel PC 677/677B, Panel PC 870, Panel PC 877
• SIMOTION Panel PC: P012K, P012T, P015K, P015T, PCR,
PCR-Touch
• SINUMERIK Panel PC: HT8, OP08T, OP010, OP012, TP012,
OP015, TP015, OP015A
For configuring panels released after the start of delivery of
WinCC flexible 2008, an HSP (Hardware Support Package)
is required that can be downloaded free of charge via the
following link:
http://www.siemens.com/wincc-flexible-hsp
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES
■ Design
The engineering tools of the SIMATIC WinCC flexible range are
based on one another. The available editors largely depend on
the respectively configured target systems and their functions.
A more comprehensive engineering tool such as WinCC flexible
Standard also offers the facilities of the smaller engineering
tools, e.g. WinCC flexible Compact or Micro.
Upgrading of a smaller engineering tool to a larger one is
possible using a Powerpack. An exception is WinCC flexible
Micro.
The scope of functions of the WinCC flexible engineering tools
already includes project support for the Runtime options
available for SIMATIC Panels or WinCC flexible Runtime,
independent of the RT licenses purchased. Separate licensing
is required for the target system in order to use the configured
Runtime options.
■ Function
Integration into automation systems
• Integration into SIMATIC STEP 7 V5.x and Simotion
- Management of HMI projects within the SIMATIC Manager
- Shared use of communication settings and process point
definitions, i.e., symbols and messages
- Display of the HMI configuring objects in the
SIMATIC Manager
- Transfer of configuring data via MPI/PROFIBUS/Ethernet
using routing
Configuration interface
• Comprehensive and fast access to editors and project data
via Workbench applications
• Adaptive user interface of engineering tools depending on
configured target system
• User-definable user interface settings, e.g., layout, toolbars,
object defaults
Project handling
• Device-independent configuration data can be used on a
variety of target systems without the need for conversion;
the interface adapts to the functional possibilities of the device
currently configured.
• Cross-device utilization of common configuration data
(e.g., text library) in multi-device projects
• Wizard-assisted definition of basic structure of HMI projects
(e.g., display layout, operator prompting)
Screen editor with extensive options for efficient and fast screen
configuration
• Generation of interconnected screen objects via Drag&Drop,
e.g., tags for the creation of input/output fields with process
interfacing or buttons with screen selection function
• Template for the definition of global screen objects and
functions (comparable with the Slide Master in
MS PowerPoint)
• User-friendly editor for the creation of image blocks with
defined external interface from screen objects
• Graphics-based configuration of motion paths
• Layer technology with up to 32 layers
• Tools for the Align, Rotate and Mirror functions
Import/export
• of texts for translation
• of tags, links, text lists, and messages
• Generation of variable lists for importing from controller
programming tools
Object-based data management with user-friendly search and
edit options
• Cross-reference list with direct access to all objects,
e.g. for editing or selection
• Search for objects in entire project
• Central reassignment of variables
• Text search and replace functions
Libraries for predefined/user-defined configuration objects
• Large number of scalable and dynamizable screen objects
included in scope of delivery
• Size-scalable WMF-format graphics for industrial applications
included in scope of delivery
• Preview function for library objects
• Storage of all engineering objects in library, e.g., blocks and
even entire displays or variables;
picture blocks can be created on a customer- or projectspecific basis by combining simple screen objects.
Changes to these picture blocks can be made centrally
(block definition).
Language support
• Multilingual project creation (max. 32 languages) in editors
thanks to selectable views
• Automatic translation on basis of system- and user-specific
dictionaries in central text library
• Central management of language-specific texts and graphics
in libraries
• Edit, export and import of texts for translation
• Language-specific graphics
Visual Basic Script support
• IntelliSense function for fast programming of access to
runtime objects
• Simple creation of control sequences in script code;
• Script debugging in Simulator and WinCC flexible Runtime
Test and startup support
• Simulation of HMI projects on engineering PC
• Jump to error cause based on alarm messages in the
Compiler
• Advanced ProSave service tool for all operating systems
supported by WinCC flexible
ChangeControl (option)
• Version management of project versions with rollback
• Logging of configuration changes,
e.g., for regulated industries
Note:
For further information, refer to "WinCC flexible options".
Default runtime data in engineering tools
• Users and passwords
• Recipe data records
Siemens ST 80 / ST PC · 2013
4/61
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES
■ Technical specifications
System requirements
(minimum requirements)
WinCC flexible
Engineering Software
Operating system
Windows XP Professional SP3
(32 bit),
Windows 7 Professional, Ultimate,
Enterprise (32 and 64 bit)
Additionally for
SIMATIC WinCC flexible Micro:
Windows XP Home SP3
Processor
Pentium 4 (or comparable) processor running at 1.6 GHz or faster
Resolution
1024 x 768 or higher
Main memory (RAM)
t 1 GB,
t 512 MB for WinCC flexible Micro
Hard disk (free memory space) 1)
t 2 GB 2)
t 1.2 GB for WinCC flexible Micro 3)
DVD drive
for software installation
■ Ordering data
4
6AV6610-0AA01-3CA8
WinCC flexible 2008 Compact
incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring Micro Panels, Basic Panels
and 70/170 series Panels incl.
C7-635
• Software for
WinCC flexible /ChangeControl
engineering option 1)
• Simulation software for
Micro Panels, Basic Panels, and
70/170 series Panels incl. C7-635
• Native drivers
6AV6611-0AA51-3CA5
2)
When installing one language. An additional 200 MB are required for each
further language. In the case of different partitions for system and configuration: System partition approx. 700 MB, project partition approx. 1.3 GB.
3)
When installing one language. An additional 80 MB are required for each
further language. In the case of different partitions for system and configuration: System partition approx. 600 MB, project partition approx. 600 MB.
Order No.
WinCC flexible 2008 Advanced
incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring WinCC flexible Runtime on
basic PCs/Panel PCs as well as
Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Software for
WinCC flexible /ChangeControl
engineering option 1)
• Simulation software for
WinCC flexible Runtime as well
as Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers
6AV6613-0AA51-3CA5
• Electronic documentation (.pdf)
WinCC flexible /ChangeControl
for WinCC flexible 2008
Compact/Standard/Advanced 1) 2)
Floating license, option, license key
only
• Electronic documentation (.pdf)
6AV6612-0AA51-3CA5
• Electronic documentation (.pdf)
1)
A separate license for WinCC flexible /ChangeControl must be purchased
for each engineering station
2)
The ChangeControl option has not been released for integrated operation
with STEP 7
4/62
In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk;
e.g. for the swap file. The following formula has proven itself in the past:
The size of the swap file = 3 x the size of available RAM.
For further information, refer to your Windows documentation
Order No.
WinCC flexible 2008 Micro
incl. SP3
Single license, without license key
software and documentation on
DVD, without license key, contains:
• Engineering software for configuration of Micro Panels
• Electronic documentation (.pdf)
WinCC flexible 2008 Standard
incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring Micro Panels, Basic Panels
and 70/170/270/370 series Panels
incl. C7-635/636
• Software for
WinCC flexible /ChangeControl
engineering option 1)
• Simulation software for
Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers
1)
Siemens ST 80 / ST PC · 2013
6AV6613-6AA01-3AB5
Powerpacks
SIMATIC WinCC flexible
Powerpacks
Single license, license key only
• WinCC flexible 2008 Standard
to 2008 Advanced
• WinCC flexible 2008 Compact
to 2008 Advanced
• WinCC flexible 2008 Compact
to 2008 Standard
6AV6613-2CD01-3AD5
6AV6613-2BD01-3AD5
6AV6612-2BC01-3AD5
Updates
WinCC flexible 2008
Micro Update 2008, 2008 SP1,
2008 SP2 -> 2008 SP3
6AV6610-0AA51-3CU8
WinCC flexible 2008
Compact/Standard/Advanced
Update 2008, 2008 SP1,
2008 SP2 -> 2008 SP3
6AV6613-0AA51-3CU8
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES
■ Ordering data
Order No.
Upgrades
SIMATIC WinCC flexible
2004/2005/2007
to SIMATIC WinCC flexible
2008 incl. SP3
• Upgrade to
WinCC flexible 2008 Micro 2)
• Upgrade to
WinCC flexible 2008 Compact,
incl. ChangeControl option 1)
• Upgrade to
WinCC flexible 2008 Standard,
incl. ChangeControl option 1)
• Upgrade to
WinCC flexible 2008 Advanced,
incl. ChangeControl option 1)
SIMATIC WinCC flexible ASIA
2004/2005/2007
to SIMATIC WinCC flexible ASIA
2008 incl. SP3
• Upgrade to
WinCC flexible 2008
ASIA Standard,
incl. ChangeControl option 1)
• Upgrade to
WinCC flexible 2008
ASIA Advanced,
incl. ChangeControl option 1)
6AV6610-0AA01-3CE8
6AV6611-0AA51-3CE5
6AV6612-0AA51-3CE5
6AV6613-0AA51-3CE5
6AV6613-0AA11-3CA5
• Electronic documentation (.pdf)
6AV6612-0AA11-3CE5
6AV6613-0AA11-3CE5
Versions for
China/Taiwan/Korea/Japan
WinCC flexible 2008 ASIA
Standard incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring Micro Panels, Basic Panels
and 70/170/270/370 series Panels
incl. C7-635/636
• Simulation software for
Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Native drivers
Order No.
WinCC flexible 2008 ASIA
Advanced incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring WinCC flexible Runtime as well
as Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Software for
WinCC flexible /ChangeControl
engineering option 1)
• Simulation software for
WinCC flexible Runtime as well
as Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers
6AV6612-0AA11-3CA5
• Electronic documentation (.pdf)
Documentation
(must be ordered separately)
User Manual
WinCC flexible Communication
• German
• English
• French
• Italian
• Spanish
6AV6691-1CA01-3AA0
6AV6691-1CA01-3AB0
6AV6691-1CA01-3AC0
6AV6691-1CA01-3AD0
6AV6691-1CA01-3AE0
WinCC flexible Micro
User Manual
• German
• English
• French
• Italian
• Spanish
6AV6691-1AA01-3AA0
6AV6691-1AA01-3AB0
6AV6691-1AA01-3AC0
6AV6691-1AA01-3AD0
6AV6691-1AA01-3AE0
User Manual
WinCC flexible
Compact/Standard/Advanced
• German
• English
• French
• Italian
• Spanish
6AV6691-1AB01-3AA0
6AV6691-1AB01-3AB0
6AV6691-1AB01-3AC0
6AV6691-1AB01-3AD0
6AV6691-1AB01-3AE0
4
1)
A separate license for WinCC flexible /ChangeControl must be purchased
for each engineering station
2)
Original delivery note or Certificate of License (CoL) from previous
WinCC flexible Micro is required
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/wincc-flexible
Note
Do you require a specific modification or extension to the
products described here? You will find information about the
Open Platform Program for the creation of user-specific
functions and controls for WinCC flexible under "Customized
Products".
Siemens ST 80 / ST PC · 2013
4/63
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
■ Overview
■ Application
SIMATIC WinCC flexible Runtime is the high-performance visualization software for simple visualization tasks at machine level.
It can be used as a single-user solution for all automation applications in factory automation, process automation and building
services automation.
4
PC-based visualization software for single-user systems directly
at the machine.
• Runs under Windows XP Professional and
Windows 7 Professional, Ultimate, Enterprise
• Current version: SIMATIC WinCC flexible 2008 SP3 Runtime
SIMATIC WinCC flexible Runtime is configured with the
SIMATIC WinCC flexible Advanced configuration software.
■ Benefits
• Optimum price/performance ratio thanks to individually
scalable system functionality
• Functions for all visualization tasks:
Operator functions, graphical and trend displays, signaling
system, log system, archiving (option), recipe management
(option), Audit Trail (option), process fault diagnostics (option)
• Flexible runtime functionality thanks to Visual Basic scripts
• Innovative service concepts with remote operation,
diagnostics and administration via intranet and Internet as
well as e-mail communication to increase availability (option)
• Support for simple distributed automation solutions based on
TCP/IP networks at the machine level (option)
4/64
Siemens ST 80 / ST PC · 2013
SIMATIC WinCC flexible Runtime can be used in combination
with the following operator panels:
• SIMATIC Panel PCs
- PC IL 70/77
- Microbox 420
- Panel PC 477
- Panel PC 577
- Panel PC 670/677
- Panel PC 870/877
• SIMOTION Panel PCs
- P012, P015
- PCR, PCR-Touch
• SINUMERIK Panel PCs
- HT8; OP08T
- OP010, OP012, OP015
- TP012, TP015, OP015A
• Standard PCs with resolutions (W x H in pixels) of:
- 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024,
1600 x 1200
- Widescreen format: 800 x 480, 1280 x 800, 1366 x 768,
1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200,
1980 x 1080
■ Design
SIMATIC WinCC flexible Runtime is available as a software
package with 128, 512, 2048 or 4096 PowerTags. The term
PowerTags is used exclusively to identify process variables and
range pointers that have a process link to the controller.
Variables without process link, constant limit values of variables,
and messages (up to 4000 bit-triggered messages) are also
available for additional system performance.
The range of functions of WinCC flexible Runtime includes the
centralized HMI components for visualizing and reporting, and it
can be expanded to suit requirements and costs by using
optional packages.
SIMATIC WinCC flexible Runtime is configured with the
SIMATIC WinCC flexible Advanced configuration software.
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
■ Function
Visualization via Windows-compliant operator interface
made up of parameterizable screen objects and image blocks
created on a project-specific basis:
• Numeric and alphanumeric input/output fields
• Static text and graphic display plus vector graphics
• Dynamizable graphics from HMI symbol library
• Bar graph, trend curve graph with scroll and zoom function as
well as read line
• Signal-specific text and graphic lists
• Buttons and switches for operator-process communication
• Editing fields for process values (signals)
• Analog display, slider as example for further screen objects
• Project-specific image blocks created from system basic
objects
• Graphic displays for various standard graphic formats,
e.g., bitmaps, .jpg, .wmf
Alarms and messages
• Discrete alarms and analog alarms as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7 and
SIMOTION
• Freely-definable message classes for definition of acknowledgment response and display of message events
Logging of alarms and process values 1)
• Archiving in files (e.g. CSV or TXT file) and Microsoft SQL
databases
• Online evaluation of process value archives and alarm logs
• Evaluation of process value archives and alarm logs using
standard Microsoft tools such as Excel
Recipes 1)
• Generation of data records for machine or production data
• Display or entry of data records via a configurable screen
object or via process images when distributed within the
project
• Transmission of data records from or to the PLC
• Import/export for data records from/to CSV files
Documentation of process data, alarm events and recipes
• Time- or event-driven report output
• User-definable layout
Flexible expansion of system function
• thanks to Visual Basic Script
Language support for multilingual projects
• Up to 16 online languages (incl. Asian and Cyrillic)
• Language-dependent texts and graphics
• Language selection during runtime
User-oriented access protection according to requirements
of regulated sectors
• Authentication with user ID and password
• User-group-specific rights
• Central system-wide user administration based on
SIMATIC Logon 1)
• Monitoring of changes by operators in runtime operation 1)
• Recording of operator actions in an Audit Trail 1)
PLC link for a wide variety of PLCs on-board
• Simultaneous connection using several protocols: OPC Client
or SIMATIC HMI HTTP protocol are additive, i.e. can be used
in conjunction with other PLC links
• Communication via native drivers and standard OPC channel
Open communication between
HMI systems and with higher-level systems 1)
• OPC server
• [email protected] for communication between HMI systems
based on Ethernet networks, or via the intranet/Internet:
• Read and write access to variables;
WinCC flexible Runtime or SIMATIC Panels make data
(variables) available to other SIMATIC HMI systems or Office
applications.
• A SIMATIC HMI system can be used to control or monitor
another system remotely;
entry level for client/server configurations for distributed
operator stations or for solutions with headend or control
room.
[email protected] for remote control,
diagnostics and administration via intranet and Internet 1)
• Display and control of process images on remote PC or Panel
• Sending of e-mails on demand or event-driven
• System diagnostics visualized via device-specific HTML
pages
1)
Option for SIMATIC WinCC flexible Runtime; runtime licenses
must be purchased separately. For further information, refer to
"WinCC flexible options".
System requirements
WinCC flexible Runtime
Operating system
Windows XP Professional SP3
(32 bit)
Windows XP Embedded 1)
Windows 7 Professional / Ultimate /
Enterprise (32 bit and 64 bit)
Processor 4)
• Minimum
Windows XP: 300 MHz
Windows 7: 1 GHz
Windows XP: t Pentium III, 500 MHz
Windows 7: t 1 GHz
• Recommended
Graphics
• Minimum
• Resolution
SVGA
640 x 480 to 1600 x 1200 or
800 x 480 to 1980 x 1080
RAM 2)
• Minimum
Windows XP: 128 MB
Windows 7: 1 GB
Windows XP: t 512 MB
Windows 7: t 1 GB
• Recommended
Hard disk (free memory space) 3)
t 250 MB
1)
Only for enabled platforms (e.g. Panel PC 477).
You can get information from your Siemens contact.
2)
RAM requirements are determined primarily by the size of the graphics
used.
3)
Without taking archives into account.
In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk; e.g., for the swap file. The following formula has
proven itself in the past: The size of the swap file = 3 x the size of the RAM.
For further information, refer to your Windows documentation
4)
More powerful systems (Pentium 4 and higher) may be required in order to
use options
Siemens ST 80 / ST PC · 2013
4/65
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
■ Integration
SIMATIC WinCC flexible Runtime supports linking to:
Protocol
PC interfaces
SIMATIC S5 via AS511 (TTY)
COM1/COM2 13)
S5-90U
SIMATIC 500/505 RS 232/RS 422
S5-90U
SIMATIC 505 via PROFIBUS DP
S5-100U (CPU 100, 102, 103)
SIMATIC 545/555 with CP 5434
S5-115U
(CPU 941, 942, 943, 944, 945)
SIMOTION 8)
S5-135U (CPU 928A, 928B)
SINUMERIK 9)
S5-155U (CPU 946/947, 948)
Third-party controllers
SIMATIC S5 via PROFIBUS DP 1)
CP 5512 2)
CP 5611 A2 2)
S5-95U/L2-DP master
S5-115U
(CPU 941, 942, 943, 944, 945)
S5-135U (CPU 928A, 928B)
S5-155U (CPU 946/947, 948)
SIMATIC S7 via PPI
CP 5512 2)
CP 5611 A2 2)
CP 5621 1)
CP 5613 A2
CP 5614 A2
PC/PPI adapter 3)
S7-200
4
Protocol
SIMATIC S7 via MPI
S7-200 (except CPU 212) 4)
CP 5512 2)
CP 5611 A2 2)
CP 5621 1)
CP 5711 2)
CP 5613 A2
CP 5614 A2
PC adapter USB 6)
Teleservice V6.1
S7-300
S7-400
WinAC Basis (V3.0 and higher)
WinAC RTX
SIMATIC S7 via PROFIBUS DP
5)
S7-215 4)
S7-300 CPUs
with integr. PROFIBUS interface
S7-300 with CP 342-5
CP 5512 2)
CP 5611 A2 2)
CP 5621 1)
CP 5711 2)
CP 5613 A2
CP 5614 A2
S7-400 CPUs
with integr. PROFIBUS interface
WinAC Basis (V3.0 and higher)
S7-200 with CP 243-1
S7-300 CPUs
with integral Ethernet interface
CP 1612 7)
CP 1613 A2
S7-300 with CP 343-1
S7-400 CPUs
with integral Ethernet interface
COM1/COM2
CP 1612 7)
GE Fanuc (SNP/SNPX)
COM1/COM2
LG GLOFA GM
COM1/COM2
Mitsubishi (FX/MP4)
COM1/COM2
Modicon (Modbus)
COM1/COM2
Modicon (Modbus TCP/IP)
CP 1612 7)
OMRON (Link/Multilink)
COM1/COM2
OPC 10) 12)
Data Access V2.05a (client + server)
CP 1612 7)
Data Access XML V1.00 (client)
HTTP communication for data
exchange between SIMATIC HMI
(client + server) 11) 12)
CP 1612 7)
1)
WinCC flexible Runtime is passive (DP slave); the function block required
for the link is included in the scope of delivery of WinCC flexible
2)
For Microbox 427 and Panel PC 477/577/677 via internal MPI/DP interface
3)
Only point-to-point to S7-200; no configuration download, operating
systems: Windows 2000/XP; Order number: 6ES7 901-3CB30-0AX0
4)
Constraint with regard to baud rate for S7-200; see Catalog ST 70
5)
WinCC flexible RT is active; communication with S7 functions
6)
Only point-to-point to S7-300/-400; No configuration download, operating
systems: Windows 2000/XP; order number: 6ES7 972-0CB20-0XA0 (USB)
7)
For Microbox 427 and Panel PC 477/577/677/877 via internal Ethernet
interface
8)
For further information, see Catalog PM 10
9)
"SINUMERIK HMI copy license OA" option required; for further information,
see Catalog NC 60
10)
OPC Client is included in scope of delivery,
the "WinCC flexible /OPC Server for WinCC flexible Runtime" license is
required for the OPC Server option
11)
"WinCC flexible /[email protected] for WinCC flexible Runtime" license
required
12)
OPC and HTTP communication are additive, i.e. can be used in
conjunction with the PLC links listed above
13)
Via PC cable with integrated level converter RS 232/TTY;
Order number: 6ES5 734-1BD20
For information about SIMATIC Panels that support OPC/http
communication, see the overview under "System interfaces".
S7-400 with CP 443-1
WinAC Basis (V3.0 and higher)
WinAC RTX
SIMATIC S7 via integrated interface
Internal system interface
WinAC RTX
4/66
CP 5512 2)
CP 5611 A2 2)
Allen Bradley (Ethernet)
WinAC RTX
SIMATIC S7 via Ethernet (TCP/IP)
COM1/COM2
Allen Bradley (DF1/DH485)
S7-400 with CP 443-5 or IM 467
WinAC Basis (V2.0 and higher)
PC interfaces
SIMATIC 505 NITP
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
■ Integration (continued)
Application note
In parallel with each and every PLC link, WinCC flexible Runtime
supports the use of the OPC Client channel; this enables, for
example, connection to an SNMP OPC Server for the purpose of
visualizing the data stored there.
Note:
For further information, see "HMI devices/System interfaces"
The SNMP OPC Server provides a means of monitoring network
components of any type (e.g. switches) which support the SNMP
protocol. For further information, see Catalog IK PI.
Higher level visualization system
OPC Client
Industrial Ethernet
On-site visualization
OPC Server
OPC Server
4
OPC Client
SIMATIC S7-300
SIMATIC S7-400
3rd party
OPC Server
Non-Siemens
PLCs
G_ST80_XX_00077
PROFIBUS
SIMATIC WinCC flexible Runtime application example
Siemens ST 80 / ST PC · 2013
4/67
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
■ Technical specifications
Type
4
SIMATIC WinCC flexible Runtime
Type
SIMATIC WinCC flexible Runtime
The specifications are
maximum values
Password protection
• User rights
• Number of user groups
32
50
Visual Basic scripts
200
Online languages, max.
16
Displays
• Fields per screen
• Variables per screen
• Static text
• Graphics objects
• Complex objects per display
(e.g. bars)
• Trends
• Graphics lists 1)
• Text lists 1)
• Number of entries in symbol tables
500
400
400
30,000
2,000
40
Variables
4,096 3)
Messages bit-triggered / analog
• Message text (number of characters)
• Number of process values per message
• Size of message buffer
• Pending message events
4,000 / 500
80
8
Archives 4)
• Archivable data
100
Process data,
messages
500,000
• Max. number of entries per archive
(incl. all archive segments)
• Archive types
800
500
500
3,500
1,024
500
• Data storage format
Short-term archive, sequence
archive (max. 400 per archive)
CSV (Comma Separated Variable),
RDB (Runtime Data Base),
interface to MS SQL database
Recipes 4)
• Elements per recipe
• Data records per recipe
1,000
2,000 3)
5,000 2)
4/68
Siemens ST 80 / ST PC · 2013
Communication
SIMATIC S7 MPI interface/
PROFIBUS DP interface
• Number of connectable stations,
max.
Depending on the scope of the
configuration (communication) from
the point of view of WinCC flexible
Runtime, as many as 8 connections
are possible
SIMATIC S7 PPI interface
• Number of connectable stations,
max.
1 from viewpoint of
WinCC flexible Runtime
SIMATIC S5
PROFIBUS DP interface
• Number of connectable stations,
max.
1 from viewpoint of
WinCC flexible Runtime
Multi-protocol operation
Yes, OPC Client or SIMATIC HMI
HTTP protocol are additive, i.e. can
be used in conjunction with other
PLC links
1)
Together only 500 text and graphics lists
2)
Dependent on memory medium used
3)
Dependent on number of licensed PowerTags
4)
Option for SIMATIC WinCC flexible Runtime.
For further information, refer to "WinCC flexible options".
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
■ Ordering data
SIMATIC WinCC flexible 2008
Runtime
for PC systems;
incl. SW for PC systems options 1)
Single license,
on CD-ROM incl. licensing, for:
• 128 PowerTags (RT 128)
• 512 PowerTags (RT 512)
• 2048 PowerTags (RT 2048)
• 4096 PowerTags (RT 4096)
Order No.
6AV6613-1BA51-3CA0
6AV6613-1DA51-3CA0
6AV6613-1FA51-3CA0
6AV6613-1GA51-3CA0
Powerpacks
SIMATIC WinCC flexible 2008
Runtime
Single license, only license key
for PowerTags, from
• 128 to 512 PowerTags
• 128 to 2048 PowerTags
• 512 to 2048 PowerTags
• 128 to 4096 PowerTags
• 512 to 4096 PowerTags
• 2048 to 4096 PowerTags
6AV6613-4BD01-3AD0
6AV6613-4BF01-3AD0
6AV6613-4DF01-3AD0
6AV6613-4BG01-3AD0
6AV6613-4DG01-3AD0
6AV6613-4FG01-3AD0
Updates
SIMATIC WinCC flexible 2008
Runtime
Update 2008, 2008 SP1, 2008 SP2
-> 2008 SP3
Order No.
Documentation
(must be ordered separately)
6AV6613-1XA51-3CU8
User Manual
WinCC flexible Runtime
• German
• English
• French
• Italian
• Spanish
6AV6691-1BA01-3AA0
6AV6691-1BA01-3AB0
6AV6691-1BA01-3AC0
6AV6691-1BA01-3AD0
6AV6691-1BA01-3AE0
User Manual
WinCC flexible Communication
• German
• English
• French
• Italian
• Spanish
6AV6691-1CA01-3AA0
6AV6691-1CA01-3AB0
6AV6691-1CA01-3AC0
6AV6691-1CA01-3AD0
6AV6691-1CA01-3AE0
SIMATIC HMI Manual Collection
Electronic documentation, on DVD
6AV6691-1SA01-0AX0
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, device manuals
and communication manuals for
SIMATIC HMI
4
Upgrades
SIMATIC WinCC flexible
2004/2005/2007 Runtime
to SIMATIC WinCC flexible 2008
Runtime
• Upgrade to
SIMATIC WinCC flexible Runtime
2008 PowerTags
incl. Runtime Options for:
- WinCC flexible /Archives
6AV6613-1XA51-3CE0
- WinCC flexible /Recipes
- WinCC flexible /Audit
- WinCC flexible /[email protected]
- WinCC flexible /[email protected]
- WinCC flexible /OPC server
- WinCC flexible /ProAgent
• Upgrade of the SIMATIC
WinCC flexible Panel options:
- WinCC flexible /Audit
for SIMATIC Panel
- WinCC flexible /[email protected]
for SIMATIC Panel
- WinCC flexible /[email protected]
for SIMATIC Panel
- WinCC flexible /OPC server
for SIMATIC Multi Panel
- WinCC flexible /ProAgent
for SIMATIC Multi Panel
6AV6618-7XX01-3AF0
1)
Runtime licenses for WinCC flexible Runtime options must be purchased
separately for each target system.
Siemens ST 80 / ST PC · 2013
4/69
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
■ Ordering data
Order No.
Communication
via Industrial Ethernet
CP 1613-A2
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(communications software must
be ordered separately)
SIMATIC NET IE S7-1613 V8.0 SP1
Software for S7 and open communication, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, Runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A, for 32-bit Windows 7
Professional/Ultimate for up to
4 CP 1613/CP 1613 A2 / CP 1623;
English/German
• Single license for 1 installation
• Software Update Service for one
year, with automatic extension;
requirement: Current software
version
• Upgrade S7-1613 from V6.4 to
S7-1613 V8.0 SP1
• Upgrade S7-1613 from V6.0, V6.1,
V6.2 or V6.3 to S7-1613 V8.0 SP1
4
6GK1161-3AA01
6GK1716-1CB80-3AA0
6GK1716-1CB00-3AL0
6GK1716-1CB00-3AE0
6GK1716-1CB00-3AE1
Communication via PROFIBUS
CP 5613-A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)
6GK1561-3AA01
CP 5614-A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)
6GK1561-4AA01
■ More information
Additional information is available in the Internet under:
http://www.siemens.com/wincc-flexible
Note
Do you need a specific modification or option for the products
described here? You will find information about the Open
Platform Program for the creation of user-specific functions and
controls for WinCC flexible under "Customized Products".
4/70
Siemens ST 80 / ST PC · 2013
Order No.
SIMATIC NET PB S7-5613 V8.0
SP1
Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; Runtime software,
software and electronic manual on
USB flash drive, license key on diskette, Class A, for 32-bit Windows 7
Professional/Ultimate for up to
4 CP 5613 A2, CP5614 A2,
CP 5603 / CP 5623 / CP 5624;
• Single license for 1 installation
• Software Update Service for one
year, with automatic extension;
requirement: Current software
version
• Upgrade S7-5613 from V6.4 to
S7-5613 V8.0 SP1
• Upgrade S7-5613 from V6.0, V6.1,
V6.2 or V6.3 to S7-5613 V8.0 SP1
6GK1713-5CB80-3AA0
6GK1713-5CB00-3AL0
6GK1713-5CB00-3AE0
6GK1713-5CB00-3AE1
CP 5512
PCMCIA card (32-bit CARDBUS)
for connecting a PG/Notebook to
PROFIBUS or MPI
(communications software
included in WinCC flexible).
6GK1551-2AA00
CP 5611-A2
PCI card (32-bit) for connecting
a PG/PC to PROFIBUS
(communications software included
in WinCC flexible basic package)
6GK1561-1AA01
CP 5611 MPI
Comprising CP 5611 A2 (32-bit)
and MPI cable, 5 m
6GK1561-1AM01
CP 5621
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
or MPI (communications software
included in WinCC flexible basic
package)
6GK1562-1AA00
CP 5711
USB adapter (USB V2.0) for
connecting a PG or Notebook to
PROFIBUS or MPI (2 m USB cable
and 5 m MPI cable included)
6GK1571-1AM00
PC/PPI adapter
RS 232, 9-pin; male with RS 232/PPI
converter, max. 19.2 kbps
6ES7901-3CB30-0XA0
PC adapter USB
For use with Windows 2000/XP
6ES7972-0CB20-0XA0
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
SIMATIC WinCC flexible options
■ Overview
Option for SIMATIC WinCC flexible Engineering
SIMATIC Logon for WinCC flexible
SIMATIC WinCC flexible /ChangeControl
Option for connecting PCs with SIMATIC WinCC flexible Runtime
and SIMATIC Panels to central user administration.
• Creates user administration on a central computer to which
one or more WinCC flexible stations can be connected over
Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
• SIMATIC Logon for WinCC flexible supports the user in combination with the /Audit and /ChangeControl options in meeting
requirements in accordance with FDA 21 CFR Part 11 and
EU178.
WinCC flexible/ChangeControl enables consistent backup of
configuration data. The history of changes can be verified down
to the last detail for applications requiring interruption-free proof
for the complete life cycle of a product.
• Delivered customer projects, approved reference states or
development stages are managed in a database.
• Changes to project data can be integrated without problem
into the version management using new versions.
• A rollback is possible at any time.
SIMATIC WinCC flexible /Archives
Archiving of alarms and process values
• Archiving in files (e.g. CSV file) and Microsoft SQL databases
• Online evaluation of process value archives and alarm logs
• Evaluation of process value archives and alarm logs using
standard MS tools such as Excel
SIMATIC WinCC flexible /Recipes
Generation and management of data records for machine or
production data
• Display or entry of data records via a configurable screen
object or via process images when distributed within the
project
• Transmission of data records from or to the controller
• Import/export of data sets as CSV files
SIMATIC WinCC flexible /Audit
Recording of operator actions in an Audit Trail
• Electronic signature for important operator actions relevant to
production
• The ChangeControl option supports users in respect of
tracking modifications to projects.
• Audit supports users in meeting special quality requirements,
e.g.
- Production plant requiring validation according to
21 CFR Part 11 (Food Drug Administration law)
- In respect of traceability according to EU 175/2002
(EU directive)
SIMATIC WinCC flexible /[email protected]
• Flexible solution for access to HMI systems and process data
from any location
• Communication between different SIMATIC HMI systems
SIMATIC WinCC flexible /[email protected]
• Remote maintenance and servicing of machines and plant via
Internet/intranet
• Reduced downtimes for machines and plant with direct
remote access
• Flexible solution for remote access to machines and plant
SIMATIC WinCC flexible /OPC Server
• Incorporation of automation components from different
vendors into a single automation concept
• Communication for data exchange between HMI systems
and/or higher-level control system
• Communication with applications from different vendors,
e.g. MES, ERP or applications in the office sector
SIMATIC WinCC flexible /ProAgent
• Precise and rapid process fault diagnostics in plant and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various SIMATIC
components
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time
Siemens ST 80 / ST PC · 2013
4/71
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /ChangeControl
■ Overview
■ Application
• In machine/special machine construction for project
management, e.g. delivered customer versions and their
modifications
• For saving of intermediate states during complex new developments or expansions, with rollback facility
• During work for specific orders as basis for calculating costs
for modifications
• In regulated sectors as proof of state of plants or machines
and any modifications made to them
■ Function
• Integral GUI for management of project versions (version tree
with main line and secondary lines for modified project
versions)
• Modification log can be activated/deactivated and shows who
carried out modifications, and when/which. Modification
reasons can be entered as comments
■ Ordering data
4
• Options for the versioning of configuration data and for tracing
configuration changes (e.g. as verification in regulated
sectors)
• For the engineering tool SIMATIC WinCC flexible
Compact/Standard/Advanced
• One license is required for each configuration computer
1)
6AV6613-6AA01-3AB5
The ChangeControl option has not been released for integrated operation
with STEP 7.
■ More information
■ Benefits
• Consistent backup of configuration data
- Delivered versions, approved reference states or development stages are managed in a database.
- Changes to project data can be integrated without problem
into the version management using new versions. A rollback
is possible at any time.
• Tracing of configuration changes
- The history of changes can be verified down to the last detail
for applications requiring interruption-free proof for the
complete life cycle of a product.
4/72
WinCC flexible /ChangeControl
for WinCC flexible 2008
Compact/Standard/Advanced 1)
Floating License, option,
license key only
Order No.
Siemens ST 80 / ST PC · 2013
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Archives
■ Overview
■ Function
• Time-controlled as well as manual or process-controlled
swapping out of process data and messages for long-term
archiving
• During runtime, swapped out data are read in and selectively
analyzed using WinCC flexible Runtime
- Presentation and evaluation of archived process data based
on a configurable trend display. Reading of the values is
facilitated by a read line.
- Presentation and evaluation of archived alarms based on a
configurable alarm view.
- User-friendly navigation in the archives
• External evaluation of the archives using MS standard tools
• Various archive types are supported: sequence and shortterm archives
• Archiving of process values and messages on external,
Windows-supported storage media
- CSV files
- RDB files
- Microsoft SQL server via ODBC
• Power standard functions permit user-friendly and flexible
utilization of the archives
• Option for SIMATIC WinCC flexible Runtime for archiving
process values and messages
• Archiving of process values and messages supports the
acquisition and processing of process data from an industrial
plant or machine. Evaluation of the archived process data
provides information about the operating states of the plant or
machine
• One license is required per operator station
(no license is required for SIMATIC Panels/Multi Panels)
■ Benefits
• Message and process value archives permit foresighted
diagnostics which prevents downtimes
• Early detection of danger or fault states
• Increase in product quality and productivity thanks to regular
evaluation of process value and message archives
■ Technical specifications
Type
WinCC flexible /Archives
The specifications are maximum
values
Execution platform
SIMATIC WinCC flexible Runtime
Archives
• Archivable data
• Cyclical trigger for archiving process
values (variables)
• Max. number of entries per archive
(incl. sequence archive)
• Archive types
100
Process values, messages
1s
Further use of archives for evaluation and long-term archiving
Record of repeated fault states
Optimization of maintenance cycles
Ensured quality standards
Control of quality as well as production capacity utilization
Documentation of process sequence
• Data storage format
1)
• Circulating archive
• Sequence archive
(max. 400 per archive)
CSV (Comma Separated Variable),
RDB (Runtime Data Base) and
interface to Microsoft SQL database (database not included in
scope of delivery)
■ Application
•
•
•
•
•
•
500,000 1)
Dependent on memory medium used
■ Ordering data
Order No.
WinCC flexible /Archives for
WinCC flexible 2008 Runtime 1)
Single License, license key only
6AV6618-7ED01-3AB0
WinCC flexible /Archives+
Recipes for WinCC flexible 2008
Runtime 1)
Single License for each option,
license key only
6AV6618-7GD01-3AB0
1)
One license is required for each operator station. A license is not required
for the engineering system for configuring the runtime option.
■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
Siemens ST 80 / ST PC · 2013
4/73
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Recipes
■ Overview
■ Function
• Input of data sets (e.g. operating parameters for a machine,
production data for a plastics processing machine) in
WinCC flexible Runtime, their storage, and passing on to the
PLC
• Display and input of data sets using a configurable graphics
object, or distributed among several process displays within
the project
• Data set elements are coupled to the process using direct
linking of the variables
• Transmission of data records from or to the PLC
• Powerful interfaces permit synchronized exchange of data
with the PLC
• Saving of data sets on local media or on remote data servers
via networks
• Import/export of data sets as CSV files
• Logging of data sets, e.g. as batch report/shift report
• Convenient and flexible management of data sets using
powerful standard functions
4
• Option for SIMATIC WinCC flexible Runtime for managing data
records in recipes that contain related machine or production
data
• The data in a data set can be transferred, for example, from
the control unit to the PLC to switch production to a different
product variant
• One license is required per operator station (no license is
required for SIMATIC Panels/Multi Panels)
■ Benefits
WinCC flexible recipes and the associated data sets are conveniently created using a separate editor in the WinCC flexible
Advanced engineering tool, and assigned default data.
A configurable table object is used to display the data during
runtime. Furthermore, the individual data set elements can also
be directly output for several process displays on the basis of
standard input/output boxes. The data can therefore be clearly
presented for the operator in technological layers.
■ Technical specifications
Type
• Generation and management of machine parameters and
production data on the basis of data sets, and exchange with
the automation equipment, e.g. with the machine
• Clear tabular representation of data elements with support of
a configurable graphic object, or representation in technical
relationships for several process graphics
• Simple operator prompting using standard functions
• Export/import of data sets for further processing with other
tools (e.g. MS Excel)
■ Application
• Assignment of plant/machine parameters in the production
industry
• Batch-oriented production, e.g. in the food or plastics industry
WinCC flexible /Recipes
The specifications are maximum
values
Execution platform
SIMATIC WinCC flexible Runtime
Recipes
• Entries per recipe
• Data records per recipe
• User data length in bytes
per data record
1000
2000 1)
5000 2)
8000 KB 2)
1)
Dependent on number of licensed PowerTags
2)
Dependent on memory medium used
■ Ordering data
Order No.
WinCC flexible /Recipes for
WinCC flexible 2008 Runtime 1)
Single License, license key only
6AV6618-7FD01-3AB0
WinCC flexible /Archives+Recipes
for WinCC flexible 2008 Runtime 1)
Single License for each option,
license key only
6AV6618-7GD01-3AB0
1)
One license is required for each operator station.
A license is not required for the engineering system for configuring the
Runtime option.
■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
4/74
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Audit
■ Overview
■ Benefits
• Audit supports the user in meeting special quality requirements, e.g.,
- production plant requiring validation according to 21 CFR
Part 11 FDA 2)
- in respect of traceability according to EU 175/2002 3)
• Entries in the audit trail are allocated to individual users.
This ensures that responsibilities can be clearly identified.
• The audit trail, stored as a CSV file 1), can be checked via a
security mechanism to find out if subsequent changes have
been made.
• For particularly important user actions, e.g., starting
production or loading new recipes, electronic signatures and
comments can be configured and then called up and logged
during runtime.
• Option for SIMATIC WinCC flexible Runtime as well as
SIMATIC Panels for recording operations in an audit trail, and
electronic signature
• The audit trail features a safety mechanism that indicates
subsequent manipulation.
• An easy-to-use configuration option included as standard in
WinCC flexible enables you to set:
- The operator actions to be recorded in the audit trail during
runtime
- The important operator actions requiring electronic
signature/comments during runtime
• The audit option combined with the WinCC flexible ES
ChangeControl option supports the user with plant validation
• Available for the following SIMATIC HMI systems:
TP/OP 270, TP/OP 277, MP 270B, MP 277, MP 370, MP 377,
WinCC flexible Runtime
• A license is required for every operator control unit
(panel or PC)
1)
CSV Comma Separated Values
2)
The FDA (Food and Drug Administration) is the American public health
authority
3)
21 CFR Part 11- law on plant validation
■ Technical specifications
WinCC flexible /Audit
• Plug-in flash memory card on the
panel
Archive for Audit Trail use
on the Panel
• In the higher-level PC (memory
medium) connected to the panel
via Ethernet
On the PC (storage medium)
Archive for Audit Trail use of
WinCC flexible Runtime
Execution platform
SIMATIC Panels
Mobile Panel 277, TP/OP 270,
TP/OP 277
SIMATIC Multi Panels
MP 270B, MP 277, MP 370, MP 377
PCs
SIMATIC WinCC flexible Runtime
■ Ordering data
Order No.
WinCC flexible /Audit for
SIMATIC Panels
Single license, license key only
6AV6618-7HB01-3AB0
WinCC flexible /Audit for
WinCC flexible Runtime 2008
Single license, license key only
6AV6618-7HD01-3AB0
■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
Siemens ST 80 / ST PC · 2013
4/75
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
SIMATIC Logon for WinCC flexible
■ Overview
■ Design
SIMATIC Logon and SIMATIC Logon Remote Access are
installed on a central station.
The following WinCC flexible stations are connected to the
central station via Ethernet network:
• PCs with WinCC flexible Runtime
• SIMATIC Panels from the 177 series or higher
(panels with Ethernet interface)
Licensing
The following licenses are required:
• SIMATIC Logon basic license
• SIMATIC Logon Remote Access license (3-pack license
10-pack license); more than one SIMATIC Logon Remote
Access license can be installed.
4
• Option for connecting PCs with SIMATIC WinCC flexible
Runtime and SIMATIC Panels to central user administration.
• Creates user administration on a central computer to which
one or more WinCC flexible stations can be connected over
Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
• SIMATIC Logon for WinCC flexible supports the user in combination with the /Audit and /ChangeControl options in meeting
requirements in accordance with FDA 21 CFR Part 11 and
EU178.
• Licensing:
SIMATIC Logon (basic license) and SIMATIC Logon Remote
Access (3-pack license) for connection of 3 WinCC flexible
stations to a central user administration. Additional stations
can be connected by using further SIMATIC Logon Remote
Access licenses (3-pack/10-pack).
■ Benefits
• Centralized configuration of all access authorizations of a
distributed system avoids unnecessary travel times. Timeconsuming multiple configurations for each individual local
station become unnecessary. Accordingly, users can be
easily configured from a central location.
• All access data apply throughout the plant on every
connected station. Additional access data on local
subsystems is no longer necessary.
The number of connectable stations depends on the
SIMATIC Logon Remote Access licenses used. This number is
the total of the connections provided by the individual licenses.
As an example: Two installed licenses for 10 enable the
connection of 20 stations to the central station.
■ Function
Configuration
In the first step, the following data must be saved in the user
administration of WinCC flexible on every WinCC flexible station
in the plant:
• Required user groups with associated user privileges
• IP address, port number, Windows domain of the central
station on which the central user administration is stored.
All user groups are configured with the same names in the
central user administration. All users are created here, and have
automatic access to the connected WinCC flexible stations in
accordance with the relevant user group.
If the connection fails between the central station with
SIMATIC Logon and a WinCC flexible station, the operation is
handled through an "emergency user" which must first be
preconfigured locally.
Intervals for password aging and regulations for the structure of
a password are defined according to the configuration on the
central station and then also apply to all decentrally connected
WinCC flexible stations or the respective users.
■ Technical specifications
SIMATIC Logon for
WinCC flexible
Execution platform
4/76
Siemens ST 80 / ST PC · 2013
SIMATIC Panels
Mobile Panel 177 PN;
Mobile Panel 277,
TP/OP 177B PN/DP, TP/OP 277
SIMATIC Multi Panels
MP 177, MP 277, MP 377
PCs
WinCC flexible Runtime
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
SIMATIC Logon for WinCC flexible
■ Ordering data
Order No.
SIMATIC Logon V1.5
Basic license;
for panels or WinCC flexible
Runtime stations, the corresponding
number of additional
SIMATIC Logon Remote Access
licenses is required.
6ES7658-7BX51-0YA0
SIMATIC Logon Upgrade to V1.5
6ES7658-7BX51-0YE0
SIMATIC Logon Remote Access
for WinCC flexible (3 clients)
Remote access
for 3 WinCC flexible 2008 clients;
single license for 3 remote access
clients;
type of delivery:
CD, license key disk, Certificate
of License, Terms and Conditions
The number of licensed clients is
determined based on the amount
of installed SIMATIC logon remote
access licenses.
6ES7658-7BA00-2YB0
SIMATIC Logon Remote Access
for WinCC flexible (10 clients)
Remote access
for 10 WinCC flexible 2008 clients;
single license for 10 remote access
clients;
type of delivery:
CD, license key disk, Certificate
of License, Terms and Conditions
The number of licensed clients is
determined based on the amount
of installed SIMATIC logon remote
access licenses.
6ES7658-7BB00-2YB0
■ More information
Note
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, we provide information on the Open Platform
Program for creating your own functions or Controls for
WinCC flexible.
4
Siemens ST 80 / ST PC · 2013
4/77
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /[email protected]
■ Overview
4
■ Benefits
• Option for SIMATIC WinCC flexible Runtime plus
SIMATIC Panels for communication between various
SIMATIC HMI systems.
• Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 270, TP 277, OP 270, OP 277
- MP 177, MP 270B, MP 277, MP 370, MP 377
- WinCC flexible Runtime
• Communication between HMI systems is established on the
basis of Ethernet networks, or via the intranet/Internet:
- Read and write access to variables;
WinCC flexible Runtime or SIMATIC Panels make data
(variables) available to other SIMATIC HMI systems or Office
applications.
- A SIMATIC HMI system can be used to control or monitor
another system remotely;
entry level for client/server configurations for distributed
operator stations or for solutions with headend or control
room.
• Local operation, visualization and data processing is as
possible as plant-wide access to information or central
archiving of process data. Integrated information flows ensure
an overview of the status of all processes.
• Licensing:
The license "WinCC flexible /[email protected] for Panel" or
"WinCC flexible/[email protected] for WinCC flexible Runtime"
must be installed on both the server and client HMI device.
Server applications are the options [email protected], HTTP-Server
and SOAP-Server. Client applications are the screen object
[email protected] display, and the utilization of the communication
driver SIMATIC HTTP protocol.
No license is required on the client system for access to a
[email protected] using the application [email protected] or the
Microsoft Internet Explorer. A license is also not required for
the engineering system for configuring the runtime option.
Note:
If the operator stations are accessed using the [email protected]
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
4/78
Siemens ST 80 / ST PC · 2013
• Flexible solution for location-independent access to
HMI systems and process data
• Reduction in load on fieldbuses:
WinCC flexible Runtime as well as SIMATIC Panels permit a
control system, for example, to access the process data. The
sensitive field level is not loaded by the control level as far as
the communications requirements are concerned. The
requirements are processed by WinCC flexible Runtime and
the SIMATIC Panels.
• Simple, fast configuration of communications relationships
using the WinCC flexible engineering software
■ Application
• Use of machine-level HMI systems as data servers for higherlevel automation components such as control systems or
office systems. Process values from different machines, for
example, are displayed on a process screen.
• Operator control and monitoring of machines covering large
areas with several operator stations by one operator
• Operator control and monitoring of machine-level HMI
systems from one central station (e.g. head-end station of a
production line or from a control room)
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /[email protected]
■ Application (continued)
Master Control Station
HTTP Data Client
SIMATIC HMI HTTP Protocol
Industrial Ethernet
Server 1
Server 2
HTTP-Data
Server/Client
HTTP-Data
Server/Client
Server 3
Server 4
HTTP-Data
Server/Client
HTTP-Data
Server/Client
G_ST80_XX_00070
PROFIBUS
Communication between HMI systems via Industrial Ethernet: Use of machine-level HMI systems as data servers for higher-level automation components
[email protected]
Master Station
[email protected]
Operator Station 1
Operator Station 2
Operator Station n
G_ST80_XX_00071
...
Industrial Ethernet
Application of the [email protected] concept: Coordinated operation of several operator stations
Siemens ST 80 / ST PC · 2013
4/79
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /[email protected]
■ Application (continued)
Master Control Station
[email protected] display
Industrial Ethernet
Server 1
[email protected]
Server 2
[email protected]
Server 3
Server 4
[email protected]
[email protected]
G_ST80_XX_00072
PROFIBUS
4
Use of the [email protected] display: Operator control and monitoring of machine-level HMI systems from one central station
■ Function
Communication between different SIMATIC HMI systems or
between the units of a machine or plant is carried out via
Industrial Ethernet or intranet/Internet on the basis of
[email protected]
Possible communication relationships:
• Reading and writing the variables of a SIMATIC HMI system on
the basis of an HTTP protocol
- Reading and writing the variables of different HMI systems
- Simple configuring of variables in the HMI client configuration using browsers in the WinCC flexible engineering tool
- Reading and writing the variables of an HMI system using
standard applications such as MS Excel. Communication is
made possible by embedding a script in the application, on
the basis of the SOAP protocol (Simple Object Access
Protocol) superimposed by HTTP
4/80
Siemens ST 80 / ST PC · 2013
• Remote control of an operator station;
the HMI application and communication with the PLC are via
the master station. In the case of spatially distributed
machines/plants (which require a larger number of operator
panels), so-called [email protected] can be activated from here
which are then assigned access to the master station and thus
to the process. Access procedures guarantee that only one
operator system can actively access the process at a time.
- A configurable graphic object ([email protected] display)
embedded in process displays represents the screen of the
associated HMI system ([email protected])
- Powerful standard functions permit convenient and flexible
operation of the display
Password protection can be optionally activated for access to
variables or for remote operation of an HMI system.
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /[email protected]
■ Technical specifications
Type
■ Ordering data
WinCC flexible /[email protected]
The specifications are maximum
values
Execution platform
• SIMATIC Panels
• SIMATIC Multi Panels
• PCs
Mobile Panel 177 PN,
Mobile Panel 277,
TP/OP 177B PN/DP,
TP/OP 270, TP/OP 277
MP 177, MP 270B, MP 277,
MP 370, MP 377
WinCC flexible Runtime
[email protected]
SIMATIC HMI HTTP protocol
Number of connections for one client
• Mobile Panel 177 PN,
TP/OP 177 B PN/DP,
MP 177 as HTTP server
• Mobile Panel 277, TP/OP 270,
TP/OP 277, MP 270B, MP 277,
MP 370, MP 377 as HTTP server
• for WinCC flexible Runtime
4
8
16
[email protected]
[email protected] concept
Number of [email protected] that can
connect to a [email protected] at the same
time1) 2)
• Mobile Panel 177 PN,
TP/OP 177B PN/DP,
MP 177 as [email protected]
• Mobile Panel 277, TP/OP 270,
TP/OP 277, MP 270B, MP 277 as
[email protected]
• MP 370, MP 377 as [email protected]
• for WinCC flexible Runtime as
[email protected]
Number of [email protected] displays per
screen
• for Panels/Multi Panels
• for WinCC flexible Runtime
Order No.
WinCC flexible /[email protected]
for SIMATIC Panel 1)
Single license, license key only
6AV6618-7AB01-3AB0
WinCC flexible /[email protected] for
WinCC flexible 2008 Runtime 1)
Single license, license key only
6AV6618-7AD01-3AB0
1)
The license must be installed on the server and on the client HMI device.
Server applications are the options [email protected], HTTP-Server and
SOAP-Server.
Client applications are the screen object [email protected] display, and the utilization of the communication driver HTTP protocol.
A license is not required for the engineering system for configuring the
runtime option.
■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for
WinCC flexible.
4
2 clients
3 clients for 6" devices
2 clients for 8" and 10" devices
3 clients for 12" devices
2 clients for 15" devices
1 client for 19" devices
5 clients
1
2
1)
Including 1 Service Client
2)
The [email protected] and the WinCC flexible /Pro Agent option cannot be used
simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime
options ProAgent, [email protected] and [email protected] is possible in the
context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the
MP 377. Limitation: a maximum of 2 clients can be connected simultaneously to a [email protected]
Siemens ST 80 / ST PC · 2013
4/81
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /[email protected]
■ Overview
■ Function
• Option for SIMATIC WinCC flexible Runtime and
SIMATIC Panels for remote maintenance and servicing of
machines/plant via the Internet/intranet
• Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 270, TP 277, OP 270, OP 277
- MP 177, MP 270B, MP 277, MP 370, MP 377
- WinCC flexible Runtime
• Licensing
The "WinCC flexible /[email protected] for Panel" license or
"WinCC flexible /[email protected] for WinCC flexible Runtime"
license must be installed on the operator panels that use one
of the following options/functions: [email protected], HTML pages
(mini-Web server), e-mail.
The remote service PC and engineering system do not require
a license for configuration the runtime option.
Note
If the operator stations are accessed using the [email protected]
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.
4
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
■ Benefits
• Fast elimination of faults or downtimes and thus increased
productivity by means of global access to machines/systems
by the service and maintenance personnel
• Avoids the need for site visits
■ Application
• Remote maintenance and servicing of machines and plants
via Internet/Intranet
• Calling of system information, control of target systems, and
updating of data sets via Internet/Intranet
• Automatic sending of emails to experts for fast elimination of
faults
4/82
Siemens ST 80 / ST PC · 2013
Remote operator control and monitoring of
SIMATIC HMI systems using Industrial Ethernet and/or
via the Intranet/Internet
Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for
accessing an HMI system.
Remote control of an operating station
the HMI application and communication with the controller takes
place via the HMI system. Using [email protected], the HMI systems
in the machines/systems can be serviced remotely. An access
process ensures that only one operator (either locally at the
machine or remotely via Internet Explorer) can actively access
the process at one time.
Integrated Web Server to process standard HTML pages
The following functions can be accessed from the homepage:
• Starting and stopping the HMI runtime for maintenance
• Remote access to recipe data sets, passwords and information specific to the HMI system
• Access the HMI system files via a file explorer
• Download configuration data via the Intranet/Internet
• Supplement with own HTML pages
Sending e-mails to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
• Events that trigger an e-mail:
- Reporting of a message class
- Configurable standard functions: Changing the value of a
variable, pressing a function key, scripts, etc.
• Possible e-mail content
- Subject
- Message text with process variables
- Date/Time
• The optional use of e-mail/SMS gateways enables access to
standard networks (external service provider required)
Standard functions make maintenance and service functionality
easier. WinCC flexible allows you to quickly and easily configure
maintenance and service functions.
Password protection can be activated as an option for
accessing the HMI system. Different passwords may be
configured for different functions.
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /[email protected]
■ Function (continued)
Engineering Station
PC/PG
{jwVpw
l•Ž•ŒŒ™•ŽGz›ˆ›–•
wjVwn
jˆšŒGYaG
v—Œ™ˆ›–™GŠ–•›™–“Gˆ•‹G”–•›–™•Ž
œš•ŽG›ŒGp•›Œ™•Œ›Vp•›™ˆ•Œ›Gž›
ˆŠŠŒššG›–G›ŒGŠ–”—“Œ›ŒG‹ŒŠŒb
š–›’Œ šGˆ•‹Gœ•Š›–•G’Œ š
pzkuVkzs
t–‹Œ”Vy–œ›Œ™
jˆšŒGXaG
v—Œ™ˆ›–™GŠ–•›™–“Gˆ•‹G”–•›–™•Ž
œš•ŽG›ŒGtŠ™–š–›Gp•›Œ™•Œ›G
lŸ—“–™Œ™
p•›Œ™•Œ›
p•‹œš›™ˆ“Gl›Œ™•Œ›
G_ST80_XX_00073
p•‹œš›™ˆ“G
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
n†z{_W††WWW^]
pzkuVkzs
t–‹Œ”Vy–œ›Œ™
wyvmpi|z
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
zt{wGzŒ™Œ™
p•‹œš›™ˆ“G
p•›Œ™•Œ›
pzkuVkzs
t–‹Œ”V
y–œ›Œ™
l•Ž•ŒŒ™•ŽG
z›ˆ›–•GwjVwn
{jwVpw
{jwVpw
pzkuVkzs
t–‹Œ”Vy–œ›Œ™
žžžSGtlzS
vŠŒGˆ™Œˆ
p•‹œš›™ˆ“G
l›Œ™•Œ›
G_ST80_XX_00074
wyvmpi|z
p•›Œ™•Œ›
zŒ™ŠŒ
w™–‹Œ™
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
n†z{_W††WWW^\
pzkuVkzs
t–‹Œ”Vy–œ›Œ™
wyvmpi|z
Sending e-mails to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
Siemens ST 80 / ST PC · 2013
4/83
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /[email protected]
■ Technical specifications
Type
■ Ordering data
WinCC flexible /[email protected]
Execution platform
• SIMATIC Panels
• SIMATIC Multi Panels
• PCs
Mobile Panel 177 PN,
Mobile Panel 277, TP 177B PN/DP,
OP 177B PN/DP, TP/OP 270,
TP/OP 277
MP 177, MP 270B, MP 277, MP 370,
MP 377
SIMATIC WinCC flexible Runtime
[email protected] 1)
Remote access via
HTML pages
• for Panels/Multi Panels
Internet Explorer V6.0 SP1 and
higher
• for WinCC flexible Runtime
HTML V1.1
(no support for ActiveX, Java, ASP)
HTML V1.1
Sending emails
• via SMTP server
• Subject, message texts with
250 characters of text per email;
date/time of message,
message No.
1)
4
The [email protected] and the WinCC flexible /ProAgent option cannot be used
simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime
options ProAgent, [email protected] and [email protected] is possible in the
context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the
MP 377. Limitation: a maximum of 2 clients can be connected with a
[email protected]
4/84
Siemens ST 80 / ST PC · 2013
Order No.
WinCC flexible /[email protected]
for SIMATIC Panels 1)
Single license, license key only
6AV6618-7BB01-3AB0
WinCC flexible /[email protected] for
WinCC flexible Runtime 2008 1)
Single license, license key only
6AV6618-7BD01-3AB0
1)
The "WinCC flexible /[email protected] for Panel" license or
"WinCC flexible /[email protected] for WinCC flexible Runtime" license must
be installed on the operator panels that use one of the following options:
[email protected], HTML pages, e-mail. The remote service PC and
engineering system do not require a license for configuration of the
Runtime option.
■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /OPC server
■ Overview
Higher level visualization system
OPC Client
Industrial Ethernet
On-site visualization
OPC Server
OPC Server
OPC Server
Multi Panel
OPC Client
PROFIBUS
SIMATIC
S7-300
SIMATIC
S7-400
3rd party
OPC Server
• Option for SIMATIC WinCC flexible Runtime as well as Multi
Panels for communication with applications from different
vendors (e.g. MES, ERP, or applications in the office sector)
G_ST80_XX_00078
3rd party
PLCs
• Available for the following SIMATIC HMI systems:
- Mobile Panel 277, MP 270B, MP 277, MP 370, MP 377
(use of OPC on XML basis)
- WinCC flexible Runtime (use of OPC based on DCOM)
• One license is required for each operator station.
■ Benefits
• Incorporation of automation components from different
vendors into an automation concept
• Saving of development costs through communication
between automation systems based on a homogeneous,
uniform protocol
• Reduction in load on fieldbuses:
WinCC flexible Runtime as well as SIMATIC Panels permit
a control system, for example, to access the process data.
The sensitive field level is not loaded by the control level as far
as the communications requirements are concerned. The
requirements are processed by WinCC flexible Runtime and
the SIMATIC Panels.
■ Application
OPC (OLE for Process Control) is a standardized, open, uniform
and multi-vendor software interface. OPC is based on the
Windows technology of COM (Component Object Model),
DCOM (Distributed COM) or on XML.
Windows-based systems such as SIMATIC Panel PC or
SIMATIC Multi Panels are used for tasks at the machine and
process levels, and can communicate with all OPC-compatible
applications via Ethernet using TCP/IP and OPC. WinCC flexible
Runtime or the SIMATIC Multi Panel (OPC server) provide data
for one or more OPC clients. As a result, local visualization and
data processing are possible to the same extent as plant-wide
calling of information or archiving of process data. Uniform flows
of information guarantee an overview of the status of all
processes.
Communication with OPC-compatible applications from different
vendors (e.g. MES, ERP, or applications in the office sector) is
possible.
OPC Foundation
http://www.opcfoundation.org
Siemens ST 80 / ST PC · 2013
4/85
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /OPC server
■ Function
■ Ordering data
• Use of a visualization system as a data server (OPC server) for
higher-level automation components such as control systems
or office systems
- OPC-XML server for multi panels
- OPC server (DCOM) for WinCC flexible Runtime
• The WinCC flexible engineering system can conveniently
select a desired OPC item from the variables function of the
OPC server using an OPC browser (component of the OPC
server). To do this, the OPC server must be started and must
be accessible for the engineering system.
Execution platform
• SIMATIC Panels
• SIMATIC Multi Panels
• PCs
OPC server
• XML server for Multi Panels
4
• DCOM server for
WinCC flexible Runtime
• Number of connections that an
OPC server can accommodate
1)
WinCC flexible /OPC server
for WinCC flexible Runtime 2008 1)
Single license, license key only
6AV6618-7CD01-3AB0
1)
One license is required for each operator station.
A license is not required for the engineering system for configuring the
Runtime option.
WinCC flexible /OPC Server
Note
The specifications are maximum
values
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
Mobile Panel 277
MP 270B, MP 277, MP 370, MP 377
SIMATIC WinCC flexible Runtime
Supports the OPC XML Data
Access specification V1.0 1)
Supports the OPC Data Access
specification V1.0a and V2.0
8
Data access via XML has a functional scope that is similar to OPC Data
Access. A software adapter is required that must be installed on the OPC
client PC to enable DCOM-based OPC clients to access the OPC XML
server without any modification. The software adapter is supplied with
WinCC flexible Engineering and Runtime.
4/86
6AV6618-7CC01-3AB0
■ More information
■ Technical specifications
Type
Order No.
WinCC flexible /OPC Server
for SIMATIC Multi Panels 1)
Single license, license key only
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /ProAgent
■ Overview
■ Ordering data
Order No.
WinCC flexible /ProAgent
Software option package for
process diagnostics based on
Functional enhancement for
SIMATIC WinCC flexible; electronic
documentation in English, French,
German, Italian, and Spanish
• WinCC flexible /ProAgent
for SIMATIC Panels 1)
Runtime license (Single License)
executable on Mobile Panel 277,
TP/OP/MP 270/277 and
MP 370/377
• WinCC flexible/ProAgent for
WinCC flexible Runtime 2008 1)
Runtime license (single license)
67(3
G_ST80_XX_00367
1)
• Targeted and rapid process diagnostics in plants and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various SIMATIC
components
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time
6AV6618-7DB01-3AB0
6AV6618-7DD01-3AB0
One license is required for each operator station. A license is not required
for the engineering system for configuring the Runtime option.
■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
Note
For further information, refer to
"SIMATIC ProAgent Process Diagnostics Software".
Siemens ST 80 / ST PC · 2013
4/87
4
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Overview
Current versions:
SIMATIC WinCC V7.2
Executable with:
• Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
• Windows XP Professional SP3
• Windows Server 2003 SP2, Standard
• Windows Server 2008 SP2 (32 bit) Standard
• Windows Server 2008 R2 SP1 (64 bit) Standard
• contains the Microsoft SQL Server 2008 R2 SP1 (32 bit)
SIMATIC WinCC V7.0 SP3
4
• PC-based operator control and monitoring system for visualizing and operating processes, production flows, machines
and plants in all sectors – from the simple single-user station
through to distributed multi-user systems with redundant
servers and cross-location solutions with Web clients. WinCC
is the information hub for corporation-wide vertical integration.
• The basic system configuration (WinCC basic software)
includes industry-standard functions for signaling and
acknowledging events, archiving of messages and measured
values, logging of all process and configuration data, user
administration and visualization.
• The WinCC basic software forms the core of a wide range of
different applications. Based on the open programming interfaces, a wide range of WinCC options (from Siemens Industry
Automation) and WinCC add-ons have been developed
(by Siemens-internal and external partners).
• WinCC can be operated with every PC that meets the given
HW requirements. The SIMATIC Box / Panel PC and SIMATIC
Rack PC product range in particular is available for the industrial use of WinCC systems. SIMATIC PCs impress with their
powerful PC technology, are designed for round-the-clock
operation, and can be operated in both office areas and harsh
industrial environments.
• SIMATIC WinCC can be ordered in combination with a
SIMATIC IPC (Box/Rack/Panel PC) as SIMATIC HMI Package
at a price advantage
• Together with the SIMATIC IPC427C and IPC477C there are
turnkey solutions available as WinCC standard client or single
station (see also Packages and IPC427C/IPC477C)
4/88
Siemens ST 80 / ST PC · 2013
Executable with:
• Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
• Windows XP Professional SP3
• Windows Server 2003 SP2 and
Windows Server 2003 R2 SP2 Standard
• Windows Server 2008 SP2 (32 bit) Standard
• Windows Server 2008 R2 SP1 (64 bit) Standard
includes the Microsoft SQL Server 2005 SP4
• Use in virtual environments – for additional information, see
http://support.automation.siemens.com/WW/view/en/
49370459
SIMATIC WinCC V6.2 SP3
Executable with:
• Windows XP Professional SP3
• Windows 2000 Professional SP4
• Windows Server 2003 SP2 and Windows Server 2003 R2 SP2
include Microsoft SQL Server 2005 SP2
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Benefits
• All-purpose
- Solutions for all sectors
- Multilingual for worldwide usage
- Can be integrated into all automation solutions
• All HMI functions on board
- User administration
- Operator control and monitoring
- Reporting, acknowledging, and archiving of events
- Acquisition, compression and archiving of measured values
(incl. long-term backup)
- Logging and documenting of process and configuration
data
• Can be configured simply and efficiently
- Configuration wizards let the user focus on the essentials
- In the picture by means of cross-reference lists and screen
property displays
- Configuration of multilingual applications
- Configuring tool for configuring bulk data
• Universally scalable
- Expandable from single station to client-server configurations
- Increased availability by means of redundant servers
- Process visualization via the web with the
WinCC WebNavigator
• Open standards for simple integration
- Powerful real-time database Microsoft SQL Server 2008 R2
SP1 (32 bit)
- Open for application modules with ActiveX controls
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication
• Process visualization with Plant Intelligence
- Integrated high-performance Historian on the basis of the
Microsoft SQL Server 2008 R2 SP1 (32 bit)
- Integrated evaluation functions for the online analysis
(statistical process control)
- Production optimization with the help of diverse options
• Expandable using options and add-ons
- Options for scalable configurations
- Options for increasing the availability
- Options for IT & business integration
- Options for SCADA expansions
- Options for validation in accordance with
FDA 21 CFR Part 11
- Options for the use of telecontrol protocols
• Part of Totally Integrated Automation
- Direct access to the tag and message configuration of the
SIMATIC control system
- Integrated diagnostic functions for increasing productivity
- Options for the use of telecontrol protocols
New in V7.2
• Expansion into Graphic Designer
- Know-how protection by means of password protection for
PDL images and image blocks
• Unicode support
- WinCC SETUP in 5 languages / up to 9 installed languages
- Individual language selection for engineering and runtime,
regardless of the language settings in the operating system
• Simplified configuration of the Tag Management by means of
the innovative WinCC Configuration Studio
- Configuration options similar to those in Excel
- Simplified tags / structure tag management
• New communication channels
- Communication channel to new CPU (S7-1200 / S7-1500)
(absolute address only, no CPU alarming support)
- Introduction of the OPC UA server (DA, HDA)
• Expansion into archive system
- New archive recording (day, weak, year)
- New archiving methods (difference)
and more ...
4
Siemens ST 80 / ST PC · 2013
4/89
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Application
SIMATIC WinCC is designed for visualization and operation of
processes, manufacturing cycles, machines and plants. With its
powerful process interface, especially to the SIMATIC family,
and the secure data archiving, WinCC enables highly available
solutions for the process control.
The sector-neutral basic system enables universal usage in all
automation applications. Sector-specific solutions can, for
example, be implemented using WinCC options (e.g. FDA
options for the pharmaceutical industry) and sector-specific
add-ons (e.g. for the water industry).
■ Design
SIMATIC WinCC is available as a complete package and as a
runtime package with 128, 512, 2048, 8192, 65536, 102400,
153600, 262144 PowerTags 1).
PowerTags are data points that are connected to controllers or
other data sources over a WinCC channel. Up to 32 alarms can
be obtained from one data point. Moreover, internal tags without
coupling are available for additional system performance. In
addition WinCC also contains 512 archive tags. Individual
archive licenses can be obtained for greater quantity structures.
Licenses for a multi-user configuration
4
The system software with the required number of PowerTags and
additionally the option WinCC/Server must be installed on the
WinCC server.
In the basic configuration, an RT128 or RT client license is sufficient for the WinCC clients. In order to configure on clients, an
RC128 or RC client license is required. Remote configuration is
possible if WinCC clients without their own project (UniClient) on
the server project are configured.
1)
■ Function
The powerful configuration functions of SIMATIC WinCC
contribute to a reduced engineering and training overhead and
lead to a more flexible use of personnel and greater operational
reliability. Whoever is familiar with Microsoft Windows can also
operate the WinCC Explorer, the central switching point of
WinCC.
In combination with other SIMATIC components, the system is
also equipped with auxiliary functions such as process
diagnostics and maintenance. All SIMATIC engineering tools
work together in the configuration of the functions.
SIMATIC WinCC offers a complete basic functionality for
process visualization and operation. To this end WinCC has a
number of editors and interfaces that can be used to individually
configure this functionality according to the respective application. Expansions of a WinCC station for control tasks are also
possible with minimal engineering effort.
WinCC editors
Task or configurable
runtime functionality
WinCC Explorer
Central project management for the
quick access to all project data and
central settings
WinCC Graphics Designer
Graphics system for user-defined
visualization and operation via pixelgraphic objects
WinCC Alarm Logging
Signaling system for detecting and
archiving events with display and
control options according to
DIN 19235; freely selectable
message classes, message display
and logging
WinCC Tag Logging
Process archiving for the acquisition, compression and storage of
measured values, e.g., presentation
in trend and table format as well as
further processing
WinCC Report Designer
Reporting and logging system for
time and event-controlled documentation of messages, operator inputs
and current process data in the form
of user reports or project documentation in an arbitrary layout
WinCC User Administrator
Tool for user-friendly administration
of users and authorizations
WinCC Global Script
Processing functions with limitless
functionality by means of the use of
VBScript and ANSI-C
V6: 128, 256, 1024, 8192, 65536 PowerTags
4/90
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Function (continued)
Integration in automation solutions
WinCC is an open process visualization system and provides the
option to connect the most diverse control systems.
Interfaces
Task or configurable
runtime functionality
Approved communication software
Only communication software with the listed product versions
(or higher) should be used. Corresponding SIMATIC NET
upgrades are available for upgrading older versions.
Communication channels
For communication with subordinate
controls (SIMATIC protocols,
PROFIBUS DP, PROFIBUS FMS,
DDE and OPC server included in
the scope of delivery)
Standard interfaces
For the open integration of other
Windows applications via WinCC,
WinCC-OLE-DB, ActiveX, OLE,
DDE, OPC, etc.)
For the number of controls connectable via Industrial Ethernet
CP 1613, the following applies to a message frame length of
512 bytes:
Programming ports
For the individual access to data
and functions of WinCC and for the
integration in user programs with
VBA, VB Script, C-API (ODK),
C-Script (ANSI-C)
Type of connection
Number of nodes
SIMATIC S5
Ethernet Layer 4 + TCP/IP
Up to 60
SIMATIC S7 Protocol Suite
Up to 64
SIMATIC 505
Ethernet Layer 4 + TCP/IP
Up to 60
■ Integration
Integration in company-wide solutions
(IT and business integration)
WinCC is strictly based on Microsoft technology, which provides
the greatest possible compatibility and integration ability.
ActiveX and .net 1) controls support technology-specific and
industry-specific expansions. Cross-manufacturer communication is also a simple exercise. The reason: WinCC can be used
as an OPC client and server, and in addition to access to current
process values, it also supports standards such as OPC HDA
(Historical Data Access), OPC Alarm & Events, and OPC XML
Data Access.
Just as important: Visual Basic for Applications (VBA) for userspecific expansions of the WinCC Graphics Designer and Visual
Basic Scripting (VBS) as an easy-to-learn, open runtime
language. If desired, professional application developers can
also use ANSI-C. And access to the API programming interfaces
is really simple with the Open Development Kit ODK.
WinCC integrates a powerful and scalable historian function
based on Microsoft SQL Server 2005 into the basic system.
As a result, users have every possibility: from high-performance
archiving of current process data, to long-term archiving with
high data compression, through to a central information hub in
the form of a company-wide process historian. With the help of
the Central Archive Server option, this can be set up within the
framework of a WinCC solution. Versatile clients and tools for
evaluation, the open interfaces, and special options (Connectivity Pack, Connectivity Station, IndustrialDataBridge) provide
the basis for effective IT and business integration.
If external networks are accessed, suitable protective measures
(incl. IT security measures, such as network segmentation)
should be taken in order to ensure safe operation of the system.
Number of connectable controls
Via PROFIBUS, a maximum of 8 controls can be connected with
CP 5611, and a maximum of 44 controls with CP 5613. With
approx. 10 or more controls, the usage of Industrial Ethernet is
recommended.
Mixed operation with different controls
With their multi-protocol stack, the CP 1613 and CP 5613
communication processors allow parallel operation of two
protocols, such as for the mixed operation of different controls,
via a bus cable. WinCC supports the operation of two similar
interface boards only in connection with the channels
SIMATIC S5 Ethernet Layer 4 (2 x CP 1613), SIMATIC S7
Protocol Suite (2 x CP 1613, 2 x CP 5613) as well as
PROFIBUS DP (4 x CP 5613; each CP 5613 max. 122 slaves).
In addition to communication over industrial Ethernet CP 1613 or
PROFIBUS CP 5613, one CP 5611 can be used in each case for
communication with SIMATIC S7 via MPI.
Client-server communication
Communication between the clients and the server is via TCP/IP
protocol. Setting up a separate PC LAN is recommended. For
small projects with a correspondingly low incidence of message
frames, SIMATIC NET Industrial Ethernet communication can be
used for both process communication (WinCC/Server l PLC)
and PC-PC communication (WinCC/client l WinCC/server).
Channel DLL PROFIBUS DP
In accordance with the PROFIBUS standard, DP/slaves are
always permanently assigned to a DP master; i.e. a second
WinCC station (DP/master) cannot access the same controls
(DP/slave). This means that redundant operation of two WinCC
stations is not possible using the PROFIBUS DP connection.
You can find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
1)
Only supported in WinCC V7.0 or higher
Siemens ST 80 / ST PC · 2013
4/91
4
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Connection to controls from other manufacturers:
OPC (OLE for Process Control) is recommended for the
connection of controls from other manufacturers.
Current notes and information about OPC servers from various
suppliers can be found at: http://www.opcfoundation.org
WinCC supports the standards:
• OPC Data Access 2.05a
• OPC Data Access 3.00
• OPC XML Data Access 1.00
(Connectivity Pack / Connectivity Station)
• OPC HDA 1.20 (Connectivity Pack / Connectivity Station)
• OPC A&E 1.10 (Connectivity Pack / Connectivity Station)
• OPC UA Client Data Access
• OPC UA Server Data Access, HDA
(Connectivity Pack / Connectivity Station)
4
Connection overview
Protocol
Description
SIMATIC S7
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
via MPI, PROFIBUS or
Ethernet Layer 4 + TCP/IP
SIMATIC S5
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4
communication + TCP/IP
SIMATIC S5 Programmer Port AS511
Channel DLL and driver for serial
communication with S5 using AS511
protocol to programmers port
SIMATIC S5 Serial 3964R
Channel DLL and driver for serial
communication with S5 using RK512
protocol
SIMATIC S5 PROFIBUS-FDL
Channel DLL for S5-FDL
SIMATIC 505
SIMATIC 505 Serial
Channel DLL and driver for serial
communication with 505 using NITP/
TBP protocol to SIMATIC 535/545/
555/565/575
SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer 4
communication
SIMATIC 505 TCP/IP
Channel DLL for 505 TCP/IP
communication
SIMATIC S7-1200, S7-1500 (WinCC 7.2 or higher)
SIMATIC S7-1200,
S7-1500 Channel 1)
Channel DLL for S7-1200
and S7-1500 communication
Controllers from other manufacturers (from WinCC V7.0 SP3)
Allen Bradley
Ethernet IP
Channel DLL and drivers for communication with Allen Bradley controllers via Ethernet TCP/IP using
Ethernet IP protocol
Modbus TCP/IP
Channel DLL and drivers for communication with Modicon controllers
via Ethernet TCP/IP using Modbus
TCP/IP protocol
Mitsubishi MC TCP/IP
Channel DLL and drivers for communication with Mitsubishi controllers via Ethernet TCP/IP using
Mitsubishi MC TCP/IP protocol
Cross-manufacturer
4/92
Siemens ST 80 / ST PC · 2013
OPC client 1) 2) for
DA, XML DA
Channel DLL for OPC communication, WinCC can acquire data from
OPC server applications.
OPC server for
DA, XML DA, A&E, HDA
Server applications for OPC communication; WinCC provides process data to OPC clients
OPC UA server for DA, HDA
Server applications for OPC UA
communication
PROFIBUS FMS
Channel DLL for PROFIBUS FMS
PROFIBUS DP
Channel DLL for PROFIBUS DP
SIMOTION
Channel DLL for SIMOTION
1)
WinCC version V7.2 or higher supports communication
with S7-1200 / S7-1500 CPU.
Restrictions: No symbolic address, type safe structure support
(absolute address only) No CPU alarming support
2)
Application note:
Parallel usage of the OPC client channel allows, for example, connection
to an SNMP-OPC server for visualization of the data contained there.
The SNMP OPC server enables monitoring of any network components
(such as switches) that support the SNMP protocol. You can find more
information under SIMATIC NET Communications Systems/SNMP OPC
Server.
3)
WinCC V7.0 SP3 and later supports OPC UA (United Architecture) Client
for DA.
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communications components for PG/PC for SIMATIC (for WinCC V7.2)
Industrial Ethernet
SIMATIC S5
Ethernet
Layer 4
SIMATIC S5
TCP/IP
•
•
SIMATIC S7
Protocol
Suite
SIMATIC 505
Ethernet
Layer 4
SIMATIC 505
TCP/IP 1)
Order No.
WinCC – channel DLL
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4
communication + TCP/IP
Included in the basic
package
Included in the basic
package
•
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer 4
communication
Included in the basic
package
•
SIMATIC 505 TCP/IP 1)
Channel DLL for 505
TCP/IP communication
•
Included in the basic
package
•
6GK1161-2AA00
Communication components for extension of the OS/OP
CP 1612
PCI card for connecting a PG/PC to
Industrial Ethernet (SOFTNET-S7 or
SOFTNET-S7 Lean communication
software must be ordered separately)
•
•
SOFTNET-S7
Communication software for
S7 functions (max. 64 connections)
• Version 8.1 2)3)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 2)
for Windows XP/2003 Server/(32-bit)
2008 Server
•
•
SOFTNET-S7 Lean
Communication software for S7
functions (max. 8 connections)
• Version 8.2 SP1 2) 4)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 2) 4)
for Windows XP/2003 Server / (32-bit)
2008 Server
•
6GK1704-1CW81-3AA0
6GK1704-1CW71-3AA0
•
6GK1704-1LW08-2AA0
6GK1704-1LW71-3AA0
CP 1613
PCI card for connecting a PG/PC
to Industrial Ethernet
(S7-1613 communication software
must be ordered separately)
•
•
•
•
•
6GK1161-3AA00
CP 1613 A2
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(S7-1613 communication software
required)
•
•
•
•
•
6GK1161-3AA01
CP 1623
PCI Express X1 card (32-bit) for
connecting a PG/PC to Industrial
Ethernet (S7-1613 communication
software required)
•
•
•
•
•
6GK1162-3AA00
S7-1613
Communication software for
S7 functions and S5/505 Layer 4
communication with TCP/IP
• Version 8.2 SP1 2)3)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server
•
•
•
•
6GK1716-1CB08-2AA0
6GK1 716-1CB71-3AA0
• System interface possible
1)
Via any interface board with NDIS 3.0 interface;
no separate communication software required
2)
See ordering data for SIMATIC NET upgrade packages
3)
SIMATIC NET Version 8.2 SP1
4)
SOFTNET-S7 Lean included in scope of supply of WinCC V7.2
Siemens ST 80 / ST PC · 2013
4/93
4
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.0)
PROFIBUS
SIMATIC S5
PROFIBUS FDL
SIMATIC S7
Protocol Suite
PROFIBUS DP
PROFIBUS FMS
Order No.
WinCC – channel DLL
SIMATIC S5 PROFIBUS FDL
Channel DLL for S5-FDL
Included in the basic
package
•
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
Included in the basic
package
•
PROFIBUS DP
Channel DLL for PROFIBUS DP
Included in the basic
package
•
•
PROFIBUS FMS
Channel DLL for PROFIBUS FMS
Included in the basic
package
Communication components for extension of the OS/OP
4
CP 5611 A2
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS or MPI
(communication software included in
WinCC basic package)
•
6GK1561-1AA01
CP 5612 2)
PCI card (32-bit) for connecting a PG/PC
to PROFIBUS (communication software
included in WinCC basic package)
•
6GK1561-2AA00
CP 5621
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (communication software included
in WinCC basic package)
•
6GK1562-1AA00
CP 5622 2)
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
(communication software included in
WinCC basic package)
•
6GK1562-2AA00
CP 5711 2)
USB adapter for connecting a PG/PC
to PROFIBUS or MPI (communication
software included in the WinCC basic
package)
•
6GK1571-1AA00
CP 5512
PCMCIA card (Cardbus 32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (communication software included
in WinCC basic package)
•
6GK1551-2AA00
• System interface possible
1)
See ordering data for SIMATIC NET upgrade package
2)
SIMATIC NET Version 8.2 SP1
4/94
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.0)
PROFIBUS
SIMATIC S5
PROFIBUS FDL
SIMATIC S7
Protocol Suite
PROFIBUS DP
PROFIBUS FMS
Order No.
Communication components for extension of the OS/OP (continued)
CP 5613 A2
PCI card (32-bit) for connecting a PC
to PROFIBUS (S7-5613, DP-5613 or
FMS-5613 communication software
required)
•
•
•
•
6GK1561-3AA01
CP 5614 A2
PCI card (32-bit) for connecting a PC
to PROFIBUS (communication software
must be ordered separately)
•
•
•
•
6GK1561-4AA01
CP 5623
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (S7-5613 communication software
or DP-5613 or FMS-5613 required)
•
•
•
•
6GK1562-3AA00
S7-5613 communication software for
S7 functions + FDL
• Version 8.1 1) 2)
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server
•
•
DP-5613
Communication software for
DP master + FDL
• Version 8.1 1) 2)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server
•
FMS-5613
Communication software for
PROFIBUS-FMS + FDL
• Edition 2008 SP2 (V7.1) 1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server
•
6GK1713-5CB81-3AA0
6GK1713-5CB71-3AA0
4
•
6GK1713-5DB81-3AA0
6GK1713-5DB71-3AA0
•
6GK1713-5FB71-3AA0
• System interface possible
1)
See ordering data for SIMATIC NET upgrade package
2)
SIMATIC NET Version 8.2 SP1
Siemens ST 80 / ST PC · 2013
4/95
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Communication examples
SIMATIC NET PROFIBUS (S7 functions)
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
- CP 5613 A2
- CP 5623
- S7-5613
(communication software)
PROFIBUS
- CP 443-5 Extended
(DP/M, S7, S/R)
- CP 443-5 Basis (FMS, S7, S/R)
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
4
SIMATIC S7-300
- CP 342-5 (DP, S7, S/R)
- CP 343-5 (FMS, S7, S/R)
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
G_ST80_XX_00010
SIMATIC S7-400
WinCC single-user system: PROFIBUS with S7 communication
SIMATIC NET Industrial Ethernet (S7 functions)
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
- CP 1613 A2
6GK1 161-3AA01
- CP 1623
6GK1 162-3AA00
- S7-1613
(communication software)
6GK1 716-1CB80-3AA0
Industrial Ethernet
- CP 443-1 (S7, S/R) ISO + TCP
6GK7 443-1EX20-0XE0
- CP 443-1 Advanced
(S7, S/R, HTTP)
6GK7 443-1GX20-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
WinCC single-user system: Industrial Ethernet with S7 communication
4/96
Siemens ST 80 / ST PC · 2013
SIMATIC S7-300
- CP 343-1 (S7, S/R) ISO + TCP
6GK7 343-1EX30-0XE0
- CP 343-1 Advanced
(S7, S/R, HTTP)
6GK7 343-1GX30-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
G_ST80_XX_00011
SIMATIC S7-400
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
SIMATIC NET PROFIBUS-FMS
- CP 5613 A2
6GK1 561-3AA00
- CP 5623
6GK1 562-3AA00
- FMS-5613
(communication software)
6GK1 713-5FB80-3AA0
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
+ FMS channel DLL
PROFIBUS FMS
SIMATIC S7-300
SIMATIC S7-400
- CP 343-5
- CP 443-5 Basic
(FMS, S7, S/R)
(FMS, S7, S/R)
6GK7 343-5FA01-0XE0 6GK7 443-5FX02-0XE0
SIMATIC S5115/135/155U
- COM 5431 FMS/DP
6GK1 745-1AD00-0EA0
G_ST80_XX_00012
- CP 5431 FMS/DP
6GK1 543-1AA01
WinCC single-user system: PROFIBUS FMS
without
operator controls:
32 clients
+ 3 web clients
or
50 web clients
+ 1 client
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
+ TCP/IP
interface module
Client
up to 4 clients
with operator
controls
Client
TERMINAL BUS TCP/IP
Server
PROCESS BUS (Industrial Ethernet/PROFIBUS)
SIMATIC S7-300
This allows you to set up the following application examples
- WinCC single-user system: SIMATIC NET PROFIBUS with S7 functions
- WinCC single-user system: SIMATIC NET Industrial Ethernet with S7 functions
- WinCC single-user system: SIMATIC NET PROFIBUS-FMS
G_ST80_XX_00013
SIMATIC S7-400
WinCC multi-user system with operable server
Siemens ST 80 / ST PC · 2013
4/97
4
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Integration (continued)
Higher-level visualisation system
- OPC server functionality
(included in WinCC basic package)
- TCP-IP interface board required
OPC Client
Industrial Ethernet
- OPC Server
functionality
(OPC Server
option for
WinCC flexible
required)
On-site visualization
OPC Server
OPC Server
- OPC Server
functionality
(included in WinCC
basic package)
- TCP-IP Interface
board required
OPC Client
OPC Server
PROFIBUS
SIMATIC S7-300
SIMATIC S7-400
third-party
PLCs
4
OPC link
4/98
Siemens ST 80 / ST PC · 2013
- OPC Client
functionality
(included in WinCC
basic package)
- OPC Server
required for
interfacing with
third-party PLCs
G_ST80_XX_00015
- integrated
PROFIBUS
interface
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Technical specifications
Type
SIMATIC WinCC V7.2 and V7.0 SP3
SIMATIC WinCC V6.2 SP3
Operating system
• Windows 7 (32 bit / 64 bit) Ultimate,
Professional and Enterprise
• Windows XP Professional SP3,
• Windows XP Professional SP3
• Windows Server 2003 SP2,
• Windows 2003 Server SP2 and
Windows 2003 Server R2 SP2
• Windows Server 2003 R2 SP2
• Windows 2000 Professional SP4,
• Windows Server 2008 SP2 (32 bit) Standard
• Windows Server 2008 R2 SP1 (64 bit) Standard
PC hardware requirements
Processor type 1)
• Minimum
Single-user station/server:
Pentium 4, 2.5 GHz 2)
Single-user station/server:
Pentium III, 1 GHz
Central Archive Server (V7.0 SP3):
Pentium 4, 2.5 GHz
Central Archive Server:
Pentium 4, 2 GHz
Client:
Pentium 3, 1 GHz 2)
Client:
Pentium III, 600 MHz
WebClient/DataMonitor Client: Pentium III, 600 MHz 2)
Single-user station/server:
Pentium 4 or Dual Core, 3 GHz 2)
Single-user station/server: Pentium 4, 2 GHz
Central Archive Server (V7.0 SP3):
Pentium 4 or Dual Core, 3 GHz
Central Archive Server:
Pentium 4, 2.5 GHz
Client: Pentium 4, 2 GHz 2)
Client: Pentium III, 1 GHz
WebClient/DataMonitor Client: Pentium III, 1 GHz
WebClient/DataMonitor Client: Pentium III, 1 GHz
Single-user station/server: 4 GB 2)
Single-user station: 512 MB, server: 1 GB
Central Archive Server: 4 GB
Central Archive Server: 1 GB
Client: 1 GB 2)
Client: 512 MB
WebClient/DataMonitor Client: 512 MB 2)
Single-user station/server: 8 GB 2)
WebClient/DataMonitor Client: 256 MB
Single-user station: >= 1 GB,
server: >1 GB
Central Archive Server: t 4 GB
Central Archive Server: t 2 GB
Client: 2 GB 2)
Client: 512 MB
WebClient/DataMonitor Client: 1 GB 2)
WebClient/DataMonitor Client: 512 MB
Graphics card
• Minimum
• Recommended
16 MB, 800 x 600 2)
32 MB, 1280 x 1024 2)
16 MB, 800 x 600
32 MB, 1280 x 1024
Hard disk
• Minimum
Single-user station/server: 80 GB
Single-user station/server: 20 GB
Client: 20 GB
Client: 5 GB
Central Archive Server: 40 GB
Central Archive Server: 40 GB
WebClient/DataMonitor Client: 5 GB
Single-user station/server: 160 GB
WebClient/DataMonitor Client: 5 GB
Single-user station/server: 80 GB
Client: 40 GB
Client: 20 GB
Central Archive Server: 2 x 80 GB
Central Archive Server: 2 x 80 GB
WebClient/DataMonitor Client: 10 GB
WebClient/DataMonitor Client: 10 GB
Server: >1.5 GB
Server: 1.5 GB
Client: 1.5 GB
Server: >10 GB
Client: 1 GB
Server: >10 GB
Client: >1.5 GB
Client: >1.5 GB
for software installation
for software installation
• Recommended
RAM
• Minimum
• Recommended
• Recommended
• Hard disk
(available memory for installation)
- Minimum
- Recommended
CD-ROM/DVD-ROM/disk drive/
USB port
1)
An AMD system with comparable performance can also be used
2)
Hardware requirements when using Microsoft XP Professional
Siemens ST 80 / ST PC · 2013
4
4/99
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Technical specifications (continued)
Type
SIMATIC WinCC
Functionality/
quantity structure
Number of messages
• Message text (number of characters)
• Message archive
• Process values per message
• Constant load of messages, max.
• Message burst, max.
Archives
• Archive data points
• Archive types
• Data storage format
• Measured values per second, max.
User archive
• Archives and views
• Product consisting of data record
and column per user archive
• Fields per user archive
4
Graphics system
• Number of screens
• Number of objects per screen
• Number of controllable fields per
screen
4/100
150,000
10 x 256
> 500,000 messages 1)
10
Central Archive Server: 100/sec
Server/single-user station: 10/s
Server/single-user station:
2,000/10 s every 5 min
Max. 120,000 per server 2)
Short-term archive with and
without long-term archiving
Microsoft SQL Server 2005
Server/single-user station: 5,000/s
500 each
320,000
500
System-limited 1)
System-limited 1)
System-limited 1)
Siemens ST 80 / ST PC · 2013
Type
SIMATIC WinCC
PowerTags
256 K 3)
Trends
• Trend views per image
• Trends per trend view
25
80
User administration
• User groups
• Number of users
• Authorization groups
128
128
999
Configuration languages
Protocols
• Message sequence reports
(simultaneously)
• Message archive reports
(simultaneously)
• User reports
• Report lines per group
• Variables per report
Multi-user system
• Server
• Clients for server
with operator station
• Clients for server
without operator station
5 European (Eng., Fr., Ger., It., Sp.),
4 Asian (simpl.+trad. Chi/Kor/Jpn) 4)
1 per server/single-user station
3
System-limited 1)
66
300 5)
18
4
32 clients + 3 WebClients or
50 WebClients + 1 client
1)
Dependent on the available storage space
2)
Dependent on the number of licensed archive variables
3)
Dependent on number of licensed PowerTags
4)
Asian versions for Version 7 SP1 or higher
5)
The number of variables per report is dependent on process communication performance
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data
Order No.
For upgrading from:
Runtime packages on DVD
Language/script versions: De, En,
Fr, It, Es; with license for
• WinCC RT Client
• 128 PowerTags (RT 128)
• 512 PowerTags (RT 512)
• 2048 PowerTags (RT 2048)
• 8192 PowerTags (RT 8192)
• 65536 PowerTags (RT 65536)
• 102400 PowerTags (RT 102400)
• 153600 PowerTags (RT 153600)
• 262144 PowerTags (RT 262144)
6AV6381-2CA07-2AX0
6AV6381-2BC07-2AX0
6AV6381-2BD07-2AX0
6AV6381-2BE07-2AX0
6AV6381-2BH07-2AX0
6AV6381-2BF07-2AX0
6AV6381-2BJ07-2AX0
6AV6381-2BK07-2AX0
6AV6381-2BL07-2AX0
Including 512 archive tags each
Complete packages on DVD
Language versions: De, En, Fr, It,
Es; with license for
• WinCC RC Client
• 128 PowerTags (RC 128)
• 512 PowerTags (RC 512)
• 2048 PowerTags (RC 2048)
• 8192 PowerTags (RC 8192)
• 65536 PowerTags (RC 65536)
• 102400 PowerTags (RC 102400)
• 153600 PowerTags (RC 153600)
• 262144 PowerTags (RC 262144)
6AV6381-2CB07-2AX0
6AV6381-2BM07-2AX0
6AV6381-2BN07-2AX0
6AV6381-2BP07-2AX0
6AV6381-2BS07-2AX0
6AV6381-2BQ07-2AX0
6AV6381-2BT07-2AX0
6AV6381-2BU07-2AX0
6AV6381-2BV07-2AX0
SIMATIC WinCC system software
V7.2 ASIA
Runtime packages on DVD
Language/script versions: En, Chs,
Cht, Kor, Jpn; with license for
• WinCC RT Client
• 128 PowerTags (RT 128)
• 512 PowerTags (RT 512)
• 2048 PowerTags (RT 2048)
• 8192 PowerTags (RT 8192)
• 65536 PowerTags (RT 65536)
• 102400 PowerTags (RT 102400)
• 153600 PowerTags (RT 153600)
• 262144 PowerTags (RT 262144)
Order No.
SIMATIC WinCC V7.2 Powerpacks
SIMATIC WinCC system software
V7.2
6AV6381-2CA07-2AV0
6AV6381-2BC07-2AV0
6AV6381-2BD07-2AV0
6AV6381-2BE07-2AV0
6AV6381-2BH07-2AV0
6AV6381-2BF07-2AV0
6AV6381-2BJ07-2AV0
6AV6381-2BK07-2AV0
6AV6381-2BL07-2AV0
Including 512 archive tags each
Complete packages on DVD
Language versions: EN, CHS, CHT,
KOR, JPN; with license for
• WinCC RC Client
• 128 PowerTags (RC 128)
• 512 PowerTags (RC 512)
• 2048 PowerTags (RC 2048)
• 8192 PowerTags (RC 8192)
• 65536 PowerTags (RC 65536)
• 102400 PowerTags (RC 102400)
• 153600 PowerTags (RC 153600)
• 262144 PowerTags (RC 262144)
6AV6381-2CB07-2AV0
6AV6381-2BM07-2AV0
6AV6381-2BN07-2AV0
6AV6381-2BP07-2AV0
6AV6381-2BS07-2AV0
6AV6381-2BQ07-2AV0
6AV6381-2BT07-2AV0
6AV6381-2BU07-2AV0
6AV6381-2BV07-2AV0
Clients
• RT Client ASIA
• RT Client
• RC Client ASIA
• RC Client
6AV6381-2CA07-2AV0
6AV6381-2CA07-2AX0
6AV6381-2CB07-2AV0
6AV6381-2CB07-2AX0
Runtime packages
• 128 to 512 PowerTags
• 512 to 2048 PowerTags
• 2048 to 8192 PowerTags
• 8192 to 65536 PowerTags
• 65536 to 102400 PowerTags
• 102400 to 153600 PowerTags
• 153600 to 262144 PowerTags
6AV6371-2BD07-2AX0
6AV6371-2BG07-2AX0
6AV6371-2BM07-2AX0
6AV6371-2BN07-2AX0
6AV6371-2BP07-2AX0
6AV6371-2BQ07-2AX0
6AV6371-2BR07-2AX0
Complete packages
• 128 to 512 PowerTags
• 512 to 2048 PowerTags
• 2048 to 8192 PowerTags
• 8192 to 65536 PowerTags
• 65536 to 102400 PowerTags
• 102400 to 153600 PowerTags
• 153600 to 262144 PowerTags
6AV6371-2BD17-2AX0
6AV6371-2BG17-2AX0
6AV6371-2BM17-2AX0
6AV6371-2BN17-2AX0
6AV6371-2BP17-2AX0
6AV6371-2BQ17-2AX0
6AV6371-2BR17-2AX0
SIMATIC WinCC V7.2 archives
• 1500 archives
• 5000 archives
• 10000 archives
• 30000 archives
• 80000 archives
6AV6371-1DQ17-2AX0
6AV6371-1DQ17-2BX0
6AV6371-1DQ17-2CX0
6AV6371-1DQ17-2EX0
6AV6371-1DQ17-2GX0
4
SIMATIC WinCC V7.2
archive powerpacks
For upgrading archiving from
• 1500 to 5000 archive tags
• 5000 to 10000 archive tags
• 10000 to 30000 archive tags
• 30000 to 80000 archive tags
6AV6371-1DQ17-2AB0
6AV6371-1DQ17-2BC0
6AV6371-1DQ17-2CE0
6AV6371-1DQ17-2EG0
SIMATIC WinCC Upgrade/
Software Update Service
SIMATIC WinCC V7.2 upgrade 1)
For upgrading the RT version
• from V6.2 to V7.2
• from V7.0 to V7.2
• from V6.2 ASIA to V7.2 ASIA
• from V7.0 ASIA to V7.2 ASIA
6AV6381-2AA07-2AX4
6AV6381-2AA07-2AX3
6AV6381-2AA07-2AV4
6AV6381-2AA07-2AV3
For upgrading the Client RT version
• from V6.2 to V7.2
• from V7.0 to V7.2
• from V6.2 ASIA to V7.2 ASIA
• from V7.0 ASIA to V7.2 ASIA
6AV6381-2BC07-2AX4
6AV6381-2BC07-2AX3
6AV6381-2BC07-2AV4
6AV6381-2BC07-2AV3
For upgrading the RC version
• from V6.2 to V7.2
• from V7.0 to V7.2
• from V6.2 ASIA to V7.2 ASIA
• from V7.0 ASIA to V7.2 ASIA
6AV6381-2AB07-2AX4
6AV6381-2AB07-2AX3
6AV6381-2AB07-2AV4
6AV6381-2AB07-2AV3
SIMATIC WinCC Software Update
Service (SUS) 2) 3)
SIMATIC WinCC V7 Update
Software Update Service for
WinCC basic software and options:
• 1 license
• 3 licenses
• 10 licenses
6AV6381-1AA00-0AX5
6AV6381-1AA00-0BX5
6AV6381-1AA00-0CX5
1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station
2)
The Software Update Service is valid for 1 year. The contract is automatically extended by 1 more year unless canceled 3 months prior to
expiration. According to licensing provisions, 1 Software Update Service
must be ordered for each WinCC station.
3)
Requires the current software version
Siemens ST 80 / ST PC · 2013
4/101
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data
Order No.
SIMATIC WinCC system software
V6.2 SP3
For upgrading from:
Runtime packages on CD-ROM
Language/script versions:
DE/EN/FR/IT/ES; with license for
• 128 PowerTags (RT 128)
• 256 PowerTags (RT 256)
• 1024 PowerTags (RT 1024)
• 8192 PowerTags (RT 8192)
• 65536 PowerTags (RT 65536)
• 102400 PowerTags (RT 102400)
• 153600 PowerTags (RT 153600)
• 262144 PowerTags (RT 262144)
6AV6381-1BC06-2AX0
6AV6381-1BD06-2AX0
6AV6381-1BE06-2AX0
6AV6381-1BH06-2AX0
6AV6381-1BF06-2AX0
6AV6381-1BJ06-2AX0
6AV6381-1BK06-2AX0
6AV6381-1BL06-2AX0
Including 512 archive tags each
Complete packages on CD-ROM
4
Language versions:
DE/EN/FR/IT/ES; with license for
• 128 PowerTags (RC 128)
• 256 PowerTags (RC 256)
• 1024 PowerTags (RC 1024)
• 8192 PowerTags (RC 8192)
• 65536 PowerTags (RC 65536)
• 102400 PowerTags (RC 102400)
• 153600 PowerTags (RC 153600)
• 262144 PowerTags (RC 262144)
6AV6381-1BM06-2AX0
6AV6381-1BN06-2AX0
6AV6381-1BP06-2AX0
6AV6381-1BS06-2AX0
6AV6381-1BQ06-2AX0
6AV6381-1BT06-2AX0
6AV6381-1BU06-2AX0
6AV6381-1BV06-2AX0
Including 512 archive tags each
SIMATIC WinCC system software
V6.2 SP3 ASIA
Runtime packages on CD-ROM
Language versions: English/simplified and traditional Chinese/Korean/
Taiwanese/Japanese; with license
for
• 128 PowerTags (RT 128)
• 256 PowerTags (RT 256)
• 1024 PowerTags (RT 1024)
• 8192 PowerTags (RT 8192)
• 65536 PowerTags (RT 65536)
Order No.
SIMATIC WinCC V6.2 Powerpacks
Runtime packages
• 128 to 256 PowerTags
• 128 to 1024 PowerTags
• 128 to 8192 PowerTags
• 128 to 65536 PowerTags
• 256 to 1024 PowerTags
• 256 to 8192 PowerTags
• 256 to 65536 PowerTags
• 1024 to 8192 PowerTags
• 1024 to 65536 PowerTags
• 8192 to 65536 PowerTags
6AV6371-1BD06-2AX0
6AV6371-1BE06-2AX0
6AV6371-1BK06-2AX0
6AV6371-1BF06-2AX0
6AV6371-1BG06-2AX0
6AV6371-1BL06-2AX0
6AV6371-1BH06-2AX0
6AV6371-1BM06-2AX0
6AV6371-1BJ06-2AX0
6AV6371-1BN06-2AX0
Complete packages
• 128 to 256 PowerTags
• 128 to 1024 PowerTags
• 128 to 8192 PowerTags
• 128 to 65536 PowerTags
• 256 to 1024 PowerTags
• 256 to 8192 PowerTags
• 256 to 65536 PowerTags
• 1024 to 8192 PowerTags
• 1024 to 65536 PowerTags
• 8192 to 65536 PowerTags
6AV6371-1BD16-2AX0
6AV6371-1BE16-2AX0
6AV6371-1BK16-2AX0
6AV6371-1BF16-2AX0
6AV6371-1BG16-2AX0
6AV6371-1BL16-2AX0
6AV6371-1BH16-2AX0
6AV6371-1BM16-2AX0
6AV6371-1BJ16-2AX0
6AV6371-1BN16-2AX0
SIMATIC WinCC V6.2 Archive
• 1500 archives
• 5000 archives
• 10000 archives
• 30000 archives
• 80000 archives
• 120000 archives
6AV6371-1DQ16-2AX0
6AV6371-1DQ16-2BX0
6AV6371-1DQ16-2CX0
6AV6371-1DQ16-2EX0
6AV6371-1DQ16-2GX0
6AV6371-1DQ16-2JX0
SIMATIC WinCC V6.2
Archive Powerpacks
6AV6381-1BC06-2AV0
6AV6381-1BD06-2AV0
6AV6381-1BE06-2AV0
6AV6381-1BH06-2AV0
6AV6381-1BF06-2AV0
Including 512 archive tags each
For upgrading archiving from
• 1500 to 5000 archive tags
• 5000 to 10000 archive tags
• 10000 to 30000 archive tags
• 30000 to 80000 archive tags
• 80000 to 120000 archive tags
Complete packages on CD-ROM
SIMATIC WinCC V6.2 upgrade 1)
Language versions: English/simplified and traditional Chinese/Korean/
Taiwanese, Japanese; with license
for
• 128 PowerTags (RC 128)
• 256 PowerTags (RC 256)
• 1024 PowerTags (RC 1024)
• 8192 PowerTags (RC 8192)
• 65536 PowerTags (RC 65536)
6AV6381-1BM06-2AV0
6AV6381-1BN06-2AV0
6AV6381-1BP06-2AV0
6AV6381-1BS06-2AV0
6AV6381-1BQ06-2AV0
Including 512 archive tags each
For upgrading the RT version
• from V5.x to V6.2 SP3
• from V6.x to V6.2 SP3
• from V5.x ASIA to V6.2 SP3 ASIA
• from V6.x ASIA to V6.2 SP3 ASIA
6AV6381-1AA06-2AX4
6AV6381-1AA06-2AX3
6AV6381-1AA06-2AV4
6AV6381-1AA06-2AV3
For upgrading the RC version
• from V5.x to V6.2 SP3
• from V6.x to V6.2 SP3
• from V5.x ASIA to V6.2 SP3 ASIA
• from V6.x ASIA to V6.2 SP3 ASIA
6AV6381-1AB06-2AX4
6AV6381-1AB06-2AX3
6AV6381-1AB06-2AV4
6AV6381-1AB06-2AV3
1)
4/102
Siemens ST 80 / ST PC · 2013
6AV6371-1DQ16-2AB0
6AV6371-1DQ16-2BC0
6AV6371-1DQ16-2CE0
6AV6371-1DQ16-2EG0
6AV6371-1DQ16-2GJ0
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station.
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data
Order No.
SIMATIC WinCC V7.2
communication
Communication via
Industrial Ethernet
CP 1612 A2
PCI card (32-bit) for connection of a
programming device or PC to Industrial Ethernet (10/100/1000 Mbps)
with RJ45 connection via
SOFTNET S7 and SOFTNET PG
SOFTNET-IE S7 Version 8.2 SP1 1)
Software for S7-compatible and
S5-compatible communication incl.
OPC server, PG/OP communication
and NCM PC; up to 64 connections;
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM;
license key on USB stick; Class A
for CP 1612-A2 English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
SOFTNET-IE S7 Lean
Version 8.2 SP1
(license included in scope of
delivery of WinCC V7.2)
Software for S7-compatible and
S5-compatible communication incl.
OPC server, PG/OP communication
and NCM PC; up to 8 connections;
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM;
license key on USB stick; Class A
for CP 1612-A2 English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1161-2AA01
Order No.
HARDNET-IE S7 V8.2 SP1 1)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC,
single license for one installation of
Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A
for CP 1613-A2, CP 1623, CP 1628;
English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1716-1CB08-2AA0
6GK1716-1CB00-3AE0
6GK1716-1CB00-3AE1
Communication via PROFIBUS
6GK1704-1CW08-2AA0
6GK1704-1CW00-3AE0
6GK1704-1CW00-3AE1
6GK1704-1LW81-3AA0
6GK1704-1LW00-3AE0
6GK1704-1LW00-3AE1
CP 1613 A2
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet (communications software must be
ordered separately)
6GK1161-3AA01
CP 1623
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)
6GK1162-3AA00
CP 1628
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)
6GK1162-8AA00
1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station
2)
The Software Update Service is valid for 1 year. The contract is automatically extended by 1 more year unless canceled 3 months prior to
expiration. According to licensing provisions, 1 Software Update Service
must be ordered for each WinCC station.
CP 5611 A2
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communications software included in the
WinCC basic package)
6GK1561-1AA01
CP 5612 2)
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communications software included in the
WinCC basic package)
6GK1561-2AA00
CP 5621
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
6GK1562-1AA00
CP 5622 2)
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
6GK1562-2AA00
CP 5711
USB adapter for connecting a
PG/PC to PROFIBUS or MPI
(communications software included
in WinCC basic package)
6GK1571-1AA00
CP 5512
PCMCIA card (CARDBUS 32-bit) for
the connection of a PG/notebook to
PROFIBUS or MPI (communications
software included in WinCC basic
package)
6GK1551-2AA00
CP 5613 A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)
6GK1561-3AA01
4
Siemens ST 80 / ST PC · 2013
4/103
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data
Order No.
Communication via PROFIBUS
(continued)
CP 5614 A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)
6GK1561-4AA01
CP 5623
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)
6GK1562-3AA00
CP 1612 A2
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(SOFTNET-S7 must be ordered
separately)
HARDNET-PB S7 V8.2 SP1 1)
Software for S7 communication incl.
PG/OP communication, FDL, OPC
server, Runtime software, software
and electronic manual on CD-ROM,
license key on USB stick, Class A
for CP 5613-A2, CP 5614-A2,
CP 5623
English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
4
Order No.
SIMATIC WinCC V6.2
communication
Communication via
Industrial Ethernet
HARDNET-PB DP V8.2 SP1 1)
Software for DP protocol incl.
PG/OP communication, FDL, DP
OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick, Class A,
for CP 5613-A2, CP 5614-A2,
CP 5623; English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1713-5CB08-2AA0
6GK1713-5CB00-3AE0
6GK1713-5CB00-3AE1
1)
6GK1713-5DB08-2AA0
6GK1713-5DB00-3AE0
6GK1713-5DB00-3AE1
(license included in scope of
delivery of WinCC V6.2)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC; up to 8 connections;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A,
for CP 1612-A2, English/German
• Single license for 1 installation
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005 1)
CP 1613 A2
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet (communications software must be
ordered separately)
6GK1713-5FB71-3AA0
6GK1713-5FB00-3AE0
6GK1713-5FB00-3AE1
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station
4/104
6GK1704-1CW71-3AA0
6GK1704-1CW00-3AE1
SOFTNET-S7 Lean V7.1 SP6
(Edition 2008+SP6) 1)
FMS-5613 V7.1 SP6
(Edition 2008+SP6) 1)
Software for FMS protocol incl.
PG/OP communication, FDL,
OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick, Class A;
for CP 5613-A2, CP 5614-A2,
CP 5623; English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
SOFTNET-S7 V7.1 SP6
(Edition 2008+SP6) 1)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC; up to 64 connections;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A,
for CP 1612-A2, English/German
• Single license for 1 installation
• Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)
6GK1161-2AA01
Siemens ST 80 / ST PC · 2013
S7-1613 V7.1 SP6
(Edition 2008+SP6) 1)
Software for S7-compatible and
S5-compatible communication
incl. PG/OP communication,
OPC server and NCM PC;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A
for CP 1613-A2; English/German
• Single license for 1 installation
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005 1)
6GK1704-1LW71-3AA0
6GK1704-1LW00-3AE1
6GK1161-3AA01
6GK1716-1CB71-3AA0
6GK1716-1CB00-3AE1
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ Ordering data
Order No.
Communication via
Industrial Ethernet
T7-1613 V7.1 SP6
(Edition 2008+SP6) 1)
Software for TF protocol, S5-compatible communication incl. OPC,
PG/OP communication (S5/505
layer 4 communication with TCP/IP)
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick; Class A
for CP 1613-A2 English/German
• Single license
• Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)
6GK1716-1TB71-3AA0
6GK1716-1CB00-3AE1
Communication via PROFIBUS
CP 5611 A2
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communications software included in the
WinCC basic package)
6GK1561-1AA01
CP 5621
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
6GK1562-1AA00
CP 5611 MPI
Comprising CP 5611 A2 and
MPI cable, 5 m
6GK1561-1AM01
CP 5621 MPI
Comprising CP 5621 (32-bit) and
MPI cable, 5 m
6GK1562-1AM00
CP 5512
PCMCIA card (CARDBUS 32-bit) for
the connection of a PG/notebook to
PROFIBUS or MPI (communications
software included in WinCC basic
package)
6GK1551-2AA00
CP 5613 A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)
6GK1561-3AA01
CP 5614-A2
PCI Card (32-Bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)
6GK1561-4AA01
1)
The SIMATIC NET PC software delivered with SIMATIC WinCC V7.2
must always be used. The scope of supply for WinCC V7.2 includes the
SIMATIC NET PC software V8.2 SP1 / supported operating systems:
32/64-bit Windows 7 Professional, Ultimate, 64-bit Windows Server 2008
R2 and SIMATIC NET PC Software V7.1 SP6 (Edition 2008+SP6) /
supported operating systems: 32-bit Windows XP Professional, Windows
Vista Professional, Ultimate, Windows Server 2003, Windows Server 2008
Standard.
Only the license is to be used from the scope of supply of the
above-listed SIMATIC NET PC software products. The licenses supplied
with SIMATIC NET V8.2 SP1 are valid for all older versions up to and
including Edition 2006.
Order No.
S7-5613 V7.1 SP6
(Edition 2008 SP6)
Software for S7 communication incl.
PG/OP communication, FDL, OPC
server; for Windows XP Professional/
2003 Server/2000 Professional/
Server for CP 5613/CP 5614;
English/German
• Single license for 1 installation
• Upgrade package
for SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)
DP-5613 V7.1 SP6
(Edition 2008 + SP6)
Software for DP protocol incl. PG/OP
communication, FDL, OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for 32-bit: Windows XP
Professional, Windows 2003 Server,
Windows VISTA Ultimate/Business;
for CP 5613 A2; English/German
• Single license for 1 installation
• Upgrade package
for SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)
FMS-5613 V7.1 SP6
(Edition 2008 + SP6)
Software for FMS protocol incl.
PG/OP communication, FDL,
FMS-OPC server, for Windows XP
Professional/2003 Server/2000
Professional/Server for
CP 5613/CP 5614; English/German
• Single license for 1 installation
• Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)
6GK1713-5CB71-3AA0
6GK1713-5CB00-3AE1
6GK1713-5DB71-3AA0
6GK1713-5DB00-3AE1
4
6GK1713-5FB71-3AA0
6GK1713-5FB00-3AE1
Hardware for process control functions
DCF-77 receiver
for time synchronization
• DCF77 (Europe)
2XV9450-1AR14
Note
For further information on control technology options see
Catalog ST PCS7.
Siemens ST 80 / ST PC · 2013
4/105
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
■ More information
WinCC language versions
SIMATIC WinCC is also offered in simplified Chinese, traditional
Chinese, Korean and Japanese especially for Asian markets.
These WinCC versions are intended for machine manufacturers,
plant constructors and exporters who supply the regions of
China, Taiwan, Korea and Japan.
WinCC ASIA includes all familiar WinCC functions and offers in
addition the configuration user interface in the respective
national language and English. The online help is available in
simplified Chinese, traditional Chinese, Korean, Japanese and
English. A Chinese, Korean, Japanese or multilingual Windows
operating system is required for operation.
WinCC ASIA is delivered on a separate DVD which contains all
of the above mentioned language versions. The corresponding
documentation can be obtained from the national subsidiaries in
China, Korea, Taiwan and Japan.
The runtime licenses are language-neutral. The English handling
program (Automation License Manager – ALM) is executable
under the Chinese, Korean and Japanese Windows versions.
In order to use the Asian languages in WinCC, an Asia hardware
dongle is required.
4
4/106
Siemens ST 80 / ST PC · 2013
Additional information is available on the Internet at:
http://www.siemens.com/wincc
Separate configurators are available for PC hardware:
• SIMATIC IPC547C, SIMATIC Rack PC 547B
• SIMATIC IPC647C, SIMATIC Rack PC 647B
• SIMATIC IPC847C, SIMATIC Rack PC 847B
• SIMATIC IPC427C
• SIMATIC IPC627C, SIMATIC Box PC 627B
• SIMATIC Box PC 827B
• SIMATIC HMI IPC577C, SIMATIC Panel PC 577B
• SIMATIC HMI IPC677C, SIMATIC Panel PC 677B
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC WinCC options
■ Overview
C
WinCis-SW
Bas C, RT
R
C
WinCtion
Op
C
WinCd-on
Ad
C
WinCtion
Op
C
WinCd-on
Ad
G_ST80_XX_00175
C
WinCtion
Op
C
WinCd-on
Ad
Options for IT and Business Integration – Plant Intelligence
• SIMATIC InformationServer
Web-based, integrated reporting from production to
management, based on archived data
• WinCC/DataMonitor
For displaying and evaluating current process states and
historical data on office PCs with standard tools
• WinCC/DowntimeMonitor
For detecting and analyzing downtimes for machines and
plants
• WinCC/Connectivity Pack
Access to WinCC archives via OPC HDA, OPC A&E,
OPC XML Server and WinCC OLE-DB /OLE-DB
• WinCC/Connectivity Station
Gateway to WinCC server data over OPC HDA, OPC A&E,
OPC XML server and WinCC OLE-DB /OLE-DB from
independent computers
• WinCC/IndustrialDataBridge
Configurable connection to databases and IT systems
The universal WinCC basic software is the basis for modular
expansions. These functional expansions can be obtained in the
form of WinCC options and as WinCC Premium add-ons.
WinCC options are created by WinCC Development and are
Siemens Industry Automation products. You can obtain support
from our Advisory Services and via the central hotline.
Options for scalable plant configurations
• WinCC/Server
For configuring a powerful client/server system
• WinCC/Web Navigator
For controlling and monitoring plants via the Internet,
in-house intranet or LAN
• WinCC/TeleControl
For connecting to outlying stations (remote terminal units =
RTUs) via telecontrol protocols in a WinCC SCADA system.
• SIMATIC ProcessHistorian
Central scalable long-term archive for the whole plant
Options for increasing the availability
• WinCC/Redundancy
For increasing system availability through redundancy
• SIMATIC Maintenance Station
For system-integrated diagnostics and plant asset
management
• WinCC/ProAgent
For reliable process diagnostics
Options for SCADA expansions
• WinCC/User Archives
For managing data records in user archives
• WinCC/Calendar Scheduler
Calendar-based planning of events
• WinCC/Event Notifier
For sending of notifications depending on specific events in
the WinCC message system
Options for sector-specific expansions
• WinCC/ChangeControl
- Change and version management
- Generation of audit trails for engineering
• WinCC/Audit
- Change management
- Generation of audit trails for engineering and runtime
• SIMATIC Logon
- Central management of WinCC users, plant-wide
(to CFR 21 Part 11)
Options for individual system expansions
• WinCC/IndustrialX 1)
For creating customized WinCC ActiveX objects in a
VB development environment
• WinCC/ODK (Open Development Kit)
For the use of open programming interfaces
1)
For WinCC V7.2, the option WinCC/IndustrialX is part of the option
WinCC/ODK.
■ More information
WinCC options
http://www.siemens.com/wincc/options
Siemens ST 80 / ST PC · 2013
4/107
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC BATCH for WinCC
■ Overview
■ Benefits
• WinCC in connection with the SIMATIC BATCH product range
offers a solution for the implementation of batch processes in
accordance with ISA S88.
• SIMATIC BATCH for WinCC is of particular interest where
different PLCs such as S7-400/300, S5 or non-Siemens PLCs
are to be used in a BATCH system.
• SIMATIC BATCH for WinCC is offered as a bundle that
includes the SIMATIC BATCH components as well as the
WinCC components.
• SIMATIC BATCH for WinCC contains the software for
SIMATIC BATCH including options, as well as for
SIMATIC WinCC including options. These products are
released for any combinations.
- SIMATIC BATCH for WinCC includes the licenses
SIMATIC BATCH Server (10 units 1)), SIMATIC BATCH CC,
and SIMATIC BATCH Recipe.
- All other SIMATIC BATCH and SIMATIC WinCC products
require the purchase of the relevant license or licenses.
1)
Current versions:
• SIMATIC BATCH for WinCC V7.1 SP1 (only runs on
Windows XP und Windows 2003 Server operating systems)
- WinCC V7.0 SP3
- SIMATIC BATCH V7.1 SP1
Configuration
S5-135U
S7-300/400
SIMATIC BATCH for WinCC
4/108
Siemens ST 80 / ST PC · 2013
SIMATIC BATCH for WinCC has been designed for:
• Batch processes in the WinCC environment in accordance
with ISA S88
• Users of S7-300, S7-400, S5 or non-Siemens controllers
• Users of STEP5/STEP7
SIMATIC BATCH for WinCC ships with the following 3 software
components and licenses:
• SIMATIC BATCH Server for 10 units
• SIMATIC BATCH Recipe system (Floating License)
• SIMATIC BATCH CC (Floating License)
PROCESS BUS
3rd-party PLCs
■ Application
■ Design
SIMATIC BATCH for WinCC
BASIC 10 Units
G_ST80_XX_00263
4
Units are the number of subsystems that can be operated with this license.
• SIMATIC BATCH for WinCC supports the user in the implementation of batch processes in accordance with ISA S88
• Modular architecture with flexible scalability and optimal
adaptation to plant size and individual requirements,
especially with regard to the use of PLCs such as
SIMATIC S7-400/300, SIMATIC S5 and non-Siemens devices
• High availability via redundant system configurations provides
protection against loss of batch data
• Cross-subsystem recipes with significant simplification of
recipe management
• Hierarchical recipes in accordance with ISA S88.01 for the
creation of recipes oriented toward process engineering
• Saving, archiving and comprehensive reporting of batch data
• Formula support
• Validation in accordance with 21 CFR Part 11 is significantly
simplified by functions such as Audit Trail (change log),
versioning of recipes, recipe operations and formulas,
electronic signature and access protection.
The following SIMATIC BATCH options can be used to expand
or configure a plant or the relevant licenses can be purchased:
• SIMATIC BATCH Recipe system (Floating License)
• SIMATIC BATCH Planning (Floating License)
• SIMATIC BATCH CC (Floating License)
• SIMATIC BATCH Library
• SIMATIC BATCH Hierarchical Recipe
• SIMATIC BATCH Formula
• SIMATIC BATCH Powerpacks (20, 40, 100, unlimited)
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC BATCH for WinCC
■ Design (continued)
SIMATIC BATCH Separation, Procedures and Formulas offers
powerful functions for the following tasks:
The following basic products and SIMATIC WinCC options can
be used to expand or configure a plant or the relevant licenses
can be purchased.
• SIMATIC WinCC RT/RC (incl. Powerpacks)
• SIMATIC WinCC/Server
• SIMATIC WinCC/Redundancy
• SIMATIC WinCC/Archives (incl. Powerpacks)
• SIMATIC Logon
All previously listed software components including options of
SIMATIC BATCH and SIMATIC WinCC are supplied with the
product SIMATIC BATCH for WinCC. In addition, supplementary
components for configuring the interfaces between WinCC and
SIMATIC BATCH are included in the basic package.
The use and compatibility of WinCC and SIMATIC BATCH
is only guaranteed for the software versions that come with
SIMATIC BATCH for WinCC.
Formula 1
Formula 2
Formula 3
Quantity
1 000 kg
500 kg
900 kg
Temperature
90 °C
10 min
80 °C
15 min
95 °C
12 min
Yes
No
100 g
Yes
No
150 g
No
Yes
50 g
Time
Salt
Pepper
Sugar
Master Recipe #1
Master Recipe #2
Master Recipe #3
The functions of SIMATIC BATCH for WinCC are based on the
SIMATIC BATCH range of products. SIMATIC BATCH for WinCC
includes the following licenses or functions:
• SIMATIC BATCH Server for 10 units
• SIMATIC BATCH CC (BATCH Control Center)
• SIMATIC BATCH Recipe System (recipe editor)
It can be used to run a SIMATIC BATCH project with
10 subsystems on a single-user station or a client/server
combination (Batch Client and Batch Server).
The capacity of the Server Basic Packages with 10 units can be
expanded to 20, 40, 100 or unlimited units using SIMATIC
BATCH Powerpacks.
SIMATIC BATCH CC offers powerful functions for the following
tasks:
• Reading in and updating the plant data of the basic
automation
• Defining user privileges for all functions, for clients or
subsystems
• Definition of material names and codes
• Managing master recipes and starting the recipe editor
• Management of libraries with recipe elements
(library operations)
• Editing of formula categories and management of associated
formulas (parameter sets)
• Creation of batches with master recipes
• Starting of batch processing and controlling of batches
• Monitoring and diagnostics of batch processing
• Recording and archiving of recipes and batch data
Use of the "SIMATIC BATCH Hierarchical Recipe" license
permits the creation of hierarchical recipes in accordance with
ISA-88
The hierarchical recipe structure is mapped on the plant module
as follows:
• Recipe procedure for controlling the process or the
production in a plant
• Partial recipe procedure for controlling a process step in a
plant unit
• Recipe operation/function to implement the process
engineering task/function in a technical facility
G_PCS7_XX_00064
■ Function
The flexibility achieved by recipes which are independent of
plant units can be increased even further if the procedure and
parameter sets (formulas) are separated from one another.
Various master recipes can be created by linking several
formulas using a recipe procedure. This enables central modification of procedures. The formula structure is determined by the
formula category defined by the user.
Compatibility
In respect of compatibility, please note that only the SIMATIC
WinCC and SIMATIC BATCH versions included in the product
package are compatible with each other. Only predecessor
products of the product bundle SIMATIC BATCH for WinCC are
upward compatible, not single components of the product range
SIMATIC WinCC and SIMATIC BATCH.
■ Integration
A detailed description of how to integrate SIMATIC Batch in
WinCC appears in the interface description "SIMATIC BATCH
Configuration Guide".
■ Ordering data
Order No.
SIMATIC BATCH for WinCC
Software bundle for the creation
of recipes and control of batch processes in accordance with ISA S88
based on SIMATIC BATCH.
• SIMATIC BATCH Server 10 units
• SIMATIC BATCH Recipe system
(Floating License)
• SIMATIC BATCH CC
(Floating License)
6ES7657-1SA17-0YA0
Siemens ST 80 / ST PC · 2013
4/109
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Information Server
■ Overview
View in the Web browser
IS client
Add-ins for
Microsoft Word and Excel
4
The Information Server is the reporting system for WinCC and
the Process Historian. Based on Microsoft Reporting Services,
the historical data (tags and alarms) are made available via a
web client.
The Information Server Client does not need a client installation.
Using a pure web client, it offers functionality for administration,
configuration, and visualization of reports. Add-ins for Microsoft
Office applications such as Word and Excel offer additional
ways to access the WinCC and Process Historian database.
Reports can be created automatically cyclically and sent by
email. The Information Server can be used on a WinCC station,
on a Process Historian, or independently.
The basic package contains licenses for three clients and one
data source. The available licenses are additive and refer to
simultaneous access to the client computer. Pre-created report,
such as for trends and alarms, are contained in the standard
package.
■ Benefits
• Central, web-based report system as interface for all
corporate areas up to the management level.
• Simple handling through use of standard tools such as
Microsoft Word and Excel
• Provision of freely configurable reports via the web
• Automatic sending of reports via email
• Import of data from any number of WinCC applications
• Transparent access to WinCC tag and alarm logs as well as
SIMATIC Process Historian data
G_PCS7_XX_00298
Process Historian and
information server (IS)
Highlights:
• Frequently used report templates for process values,
messages, and batches
• Open reporting system for creating any number of new report
templates
• Storage of configured (parameterized) report templates for
faster access
• Report export in common document formats
• Support of subscriptions for cyclic report generation including
email service
• Creation and storage of role-based dashboards
• Role management for Windows users; supports workgroups
and Active Directory; user rights can be assigned for specific
projects
• Generation of reports and inserting as graphics in Microsoft
Office Word documents
• Creation of Microsoft Excel reports for historical process
values and messages as well as storage of the Excel report
templates on the Information
• Server Support for subscriptions to Excel report templates
■ Ordering data
SIMATIC Information Server 2013
"Basic Package"
• Information server
• Information Server Client access (3)
• Information Server Datasource access (1)
SIMATIC Information Server
• 1 Client access
• 3 Client access
• 5 Client access
• 10 Client access
• 1 Datasource access
• 3 Datasource access
4/110
Siemens ST 80 / ST PC · 2013
Order No.
6AV6361-2AA01-3AA0
6AV6361-2BD01-3BB0
6AV6361-2BE01-3BB0
6AV6361-2BF01-3BB0
6AV6361-2BG01-3BB0
6AV6361-2CD01-3BB0
6AV6361-2CE01-3BB0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Logon
■ Overview
■ Function
SIMATIC Logon
Users receive a unique user ID, user name and password.
This information is stored encrypted at a central point
(for SIMATIC Logon in the Windows user management).
Functions such as changing the password, automatic logoff
after a predefined time and lockout after several incorrect entries
of a password ensure maximum security of operation.
In the case of the SIMATIC Logon, user administration is
integrated into the security system and user administration of
MS Windows.
• SIMATIC Logon (SL) for WinCC is a software option package
supporting the central administration of all WinCC users on a
plant-wide basis. The central user management with SL uses
the Windows mechanisms and is to be installed on all participating WinCC stations. The user management actions such as
logging in and out are automatically supplied in the audit trail
of WinCC/Audit and WinCC/ChangeControl by SL.
• The WinCC/Audit or WinCC/ChangeControl and
SIMATIC Logon options support users in respect of plant
validation and meet the requirements of FDA CFR 21 Part 11.
A declaration of conformity (White Paper) offers proof of this.
■ Benefits
• Central, system-wide user management
• Conforms with the requirements of the Food and Drug Administration (FDA) for the pharmaceuticals and food processing
industry
■ Design
The SIMATIC Logon Service can be used for the central user
management of a number of WinCC stations. Operation in a
Windows Workgroup or even in a domain is possible.
To meet in particular the Food and Drug Administration (FDA)
requirements for the pharmaceuticals and food processing
industry, all user and administrator actions, such as log in, log
out, password changes, incorrect password inputs, and creating
and deleting users, are recorded with timestamp in a secure
database or are available in the audit trail of WinCC/Change
Control or WinCC/Audit.
In addition, SIMATIC Logon allows setting up new users online,
plant-wide and across applications, or blocking existing users.
SIMATIC Logon also supports electronic signature.
■ Ordering data
Order No.
SIMATIC Logon V1.4 SP1
6ES7658-7BX41-2YA0
4
Central user management for
WinCC V6.2 and WinCC V7.0
Runtime license for an operator
station 1)
SIMATIC Logon V1.5 upgrade
6ES7658-7BX51-0YA0
Single License, 7 languages
(De, En, Fr, Es, Jap, Chin)
1)
SIMATIC Logon included in scope of supply of WinCC
■ More information
Information on FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC for FDA21 CFR
Part 11.
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm
Siemens ST 80 / ST PC · 2013
4/111
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station
■ Overview
• Scalability:
- Support of WinCC single-user stations and client/server
configurations.
- The SIMATIC Maintenance Station can be added to an
existing WinCC project.
• Consistency:
- The maintenance view is generated from the control project
and is consistent with it.
• Flexibility in selection of devices:
- Use of the PROFIBUS and PROFINET standards for device
interfacing.
- An additional proxy concept allows devices to be displayed
that are not included in the STEP 7 hardware configuration or
that do not support the standard diagnostics of PROFIBUS/
PROFINET.
■ Application
4
System-integrated plant asset management system
• Automatic generation of a maintenance view in WinCC from
the STEP 7 hardware configuration
• Plant-wide visualization of all automation components from the
management level to the field level in ready linked, hierarchically arranged WinCC displays
• Mapping of central and distributed SIMATIC S7 components,
PROFIBUS and PROFINET networks as well as associated
bus nodes
• Ethernet network components and industrial PCs can be
integrated through SIMATIC NET SNMP OPC Server
• Display of device status with group status generation in
overview and detail displays
• The device statuses "Maintenance required" and "Maintenance request" are supported for status-based maintenance
• Provision of uniform faceplates showing detailed information
for all components displayed
• Display of the device identification data
(electronic rating plate)
• Integrated display of the status of the request
■ Benefits
• Reducing down times:
- Problems in the plant are detected sooner due to the uniform
presentation and clear overview of all information that is
important for maintenance.
• Avoiding downtimes:
- Support of condition-based maintenance.
• Reduced maintenance costs:
- Optimization of the flow of information between production
and maintenance by submitting maintenance requests and
presenting the status of requests.
• Transparency and traceability:
- All procedures are based on messages and can therefore be
archived and traced.
- A comprehensive database is generated that can be
analyzed with WinCC functions or external tools.
4/112
Siemens ST 80 / ST PC · 2013
The SIMATIC Maintenance Station is a tool for the diagnosis and
maintenance of machines and plants. This is an option package
for STEP 7 V5.4 and WinCC V6.2 or V7.0 that generates a WinCC
maintenance view for a STEP 7 project/multiproject.
■ Design
The SIMATIC Maintenance Station is available in various
different packages:
• Basic package:
Contains all the tools needed to configure a Maintenance
Station and a license for the display of 100 devices.
• Powerpacks:
For larger quantities, powerpacks are available with licenses
for 100, 500 or 1000 devices. These can be added to the
existing licenses and can be combined as required.
In this context, devices can be:
• AS systems
• Distributed devices (PROFIBUS / PROFINET)
• PCs
• Network components
• Asset proxies
Requirements for configuring a
SIMATIC Maintenance Station
• STEP 7 license (V5.4 upwards)
• WinCC RC license (V7.0 upwards)
• The SIMATIC NET licenses required for the plant configuration
Requirements for operation of a
SIMATIC Maintenance Station
• The WinCC licenses (V7.0 upwards) complying with the plant
configuration
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station
■ Function
■ Technical specifications
Hierarchic visualization of plant components in WinCC
• Generation of a WinCC picture tree for hierarchic display of
the plant components.
• Automatic creation and linking of displays, equipment
symbols, status indicators, faceplates and the required
variables.
• Presentation of the detailed data in faceplates with selectable
views.
• Easy navigation in the plant using the WinCC Picture Tree
Manager.
• Generated pictures can be enhanced using the
WinCC Graphic Designer.
• Switchover between a WinCC SCADA project and the picture
tree of the SIMATIC Maintenance Station can be configured
using standard WinCC functions.
Hardware requirements
System
Operating system
Display of the current status of the plant and its components
• Clearly understandable status displays through the use of
uniform symbols.
• Display of no-fault status, fault, maintenance requirement and
maintenance request.
• Display of status of request for submitted repair requests.
• Display of order status.
• Display of the alarm status of the components.
Engineering station "ES"
Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
MS Windows 7 SP1.
Supported versions:
Ultimate and Professional
Maintenance Station Stand-alone /
WinCC-Station "Single-user Workstation"
Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
MS Windows 7 SP1.
Supported versions:
Ultimate and Professional
ES with Maintenance Station
Stand-alone
Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
Windows 7 SP1.
Supported versions:
Ultimate and Professional
Maintenance Station Server /
WinCC Server
Windows Server 2003 (R2) SP2
Windows Server 2008 SP2
Windows Server 2008 R2 SP1
Maintenance Station Client /
WinCC Client
Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 SP2
Windows Server 2008 R2 SP1
Windows 7 SP1.
Supported versions:
Ultimate and Professional
Display of the identification data of the plant components
• Display of the identification data available for a device in the
faceplate for the device.
• Automatic loading of the data available in the configuration
into the maintenance station.
• Reading of the "Identification & Maintenance functions
(I&M1) )" in accordance with the PROFIBUS International
specification.
• Export2) of I&M data for all devices in the form of an XML file.
Displaying alarms
• Loading of system error messages from STEP 7.
STEP 7 provides the messages in 5 languages3),
translation into additional languages is possible in STEP 7.
• Display of the most recent message in a message line.
• Presentation of the active/archived messages of the selected
device in the faceplate.
System
Clock frequency
Main
memory
Free
hard disk
space
Engineering station
2.8 GHz
1 GB
15 GB
Maintenance Station Stand-alone /
WinCC-Station "Single-user
Workstation"
2.8 GHz
1 GB
15 GB
Maintenance Station Server /
WinCC Server
2.8 GHz
1 GB
15 GB
Maintenance Station Client /
WinCC Client
2.8 GHz
512 MB
3 GB
Software requirements
Calling the STEP 7 hardware configuration
• The STEP 7 hardware configuration can be opened for a
selected device using a button in the faceplate. STEP 7 and
the project must be installed on the maintenance station for
this purpose.
1)
The Maintenance Station 2007 supports reading of I&M data for
PROFIBUS devices with C1 channel access.
2)
The I&M data loaded from the configuration are exported.
3)
For Siemens components that are included in the STEP 7 hardware
catalog.
In the case of components that are integrated in STEP 7 using GSD files,
the GSD files must support the relevant languages.
Siemens ST 80 / ST PC · 2013
4/113
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station
■ Technical specifications (continued)
■ Ordering data
Requirements for the integration of devices
Type
Integration
SIMATIC S7 controllers / I/O
• S7-300 1)
Yes
• S7-400
Yes
• WinAC
Yes
Distributed devices
• ET 200
Yes
• PROFIBUS standard slaves
Yes
• PROFINET standard devices
Yes
Comment
PROFIBUS DP and
PROFINET IO
according to STEP 7
hardware catalog
Integration using a
GSD file
Integration using a
GSD file
Network components
Ethernet network components
Yes
PROFINET network components
Yes
PROFIBUS diagnostic repeater
Yes
SIMATIC NET SNMP
OPC Server and MIB
also required
Personal Computer
4
PC/Industrial PC
Yes
SIMATIC NET SNMP
OPC Server also
required
Drives with PROFIBUS connection
Yes
For integrating
devices designed
to the PROFIDRIVE
profile, Drive ES
SIMATIC (V5.4 SP1
or higher) is required
Drives with PROFINET connection
Yes
For integrating
devices designed
to the PROFIDRIVE
profile, Drive ES
SIMATIC (V5.4 SP1
or higher) is required
Yes
Integrated via
function block
(asset proxy)
Drives
Accessory devices
Devices not configured in STEP 7
Hardware Config
1)
With S7-300, PROFIBUS/PROFINET systems are supported if they are
connected to the internal CPU interfaces
4/114
Siemens ST 80 / ST PC · 2013
Order No.
SIMATIC Maintenance Station
2009
Can be used with STEP 7 V5.4 or
higher and WinCC V7
• Basic package
with engineering software
(Floating License) and Runtime
License for 100 devices
• Powerpack 100
Runtime License
for 100 additional devices
• Powerpack 500
Runtime License
for 500 additional devices
• Powerpack 1000
Runtime License
for 1000 additional devices
• Basic demo package 2009
• Upgrade from
SIMATIC Maintenance Station
2007 to SIMATIC Maintenance
Station 2009
6ES7840-0WD01-0YA0
6ES7840-0WD11-0YD0
6ES7840-0WD21-0YD0
6ES7840-0WD31-0YD0
6ES7840-0WD01-0YA7
6ES7840-0WD01-0YE0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Process Historian
■ Overview
■ Function
Project A
Project B
OS clients
Information server
Terminal bus
OS single
station
- OS server
- Batch server
Process Historian
Automation
systems
G_PCS7_XX_00297
Plant bus
The Process Historian is a high-performance tong-term
archiving server solution that stores WinCC process values and
messages in a central database. The system offers full
scalability for performance and scope: It records and saves data
from one or several WinCC and PCS 7 projects. The number of
connected single stations, servers, or redundant server pairs is
unrestricted. SIMATIC Process Historian is designed for use
throughout your plant, below the corporate management level
(ERP, MES).
Process Historian is the basis for the Information Server
reporting system, which accesses the central Process Historian
database and ensures clear, user-friendly data visualization on
WinCC stations and office PCs.
• Real-time data storage of the WinCC archive data (process
values and messages) from any number of WinCC stations
• Visualization of the archive data on WinCC clients or WinCC
single stations either directly or using the SIMATIC Information
Server. Process Historian configuration tool for fast, simple
engineering
• The redundant Process Historian is based on Microsoft SQL
Server Mirroring (third system for monitoring the availability of
redundancy).
• The database and segmenting are set up in the initial
configuration.
• For archiving to the PH, the PH Ready component is installed
on the WinCC server
• The PH automatically detects all connected WinCC server
projects (via the PH Ready component)
• The "Process Historian Management" dashboard for
diagnostics, displaying data sources, changing the database
segmentation
■ Ordering data
Order No.
SIMATIC Process Historian Server
2013 Single License
6AV6361-1AA01-3AA0
SIMATIC Process Historian Server
2013 Single License
(Redundancy Complete)
• 2x Process Historian Server
• 2x Process Historian Server Redundancy
6AV6361-1BA01-3AA0
SIMATIC Process Historian 2013
Single License Redundancy
6AV6361-1CA01-3AA0
4
Upgrades
Upgrade from CAS
(Central Archive Server)
V7.0 SP3 to
Process Historian 2013
6AV6361-1AA01-3AE0
The central Process Historian database provides access to realtime data throughout the plant. This data is the key to sustainable
plant optimization.
Because this is a completely integratable archive system,
the engineering can also be performed without additional effort.
SIMATIC Process Historian uses the integrated relational
database Microsoft® SQL Server.
No complex reconfiguration is needed because the archive
system is integrated in WinCC. Time or event-driven archiving of
selected process values or messages in the WinCC long-term
archive is possible.
■ Benefits
• Fully integrated long-term archive solution for large volumes
of data
• Central, plant-wide long-term archive as company-wide
information hub
• Process data and messages can be archived from any
number of lower-level WinCC systems
• Plant expansions without interrupting the production process
• High availability in redundant mode
• High degree of security due to integrated backup system
• Database for analyses with the goal of optimizing the plant
and thus the productivity
Siemens ST 80 / ST PC · 2013
4/115
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Calendar Scheduler
■ Overview
■ Benefits
• Simple operation, configuration and planning of events thanks
to handling in the style of Microsoft Office Calendar
• Simple configuration of the actions by parameterization
(execution of WinCC scripts or writing of WinCC tags at certain
times)
• Configuration of recurring events taking account of configurable public holidays, vacation periods, and maintenance
periods
• Secure operation of the plant taking account of different
authentication levels
• Clear representation of events at runtime by means of
Calendar Runtime Control
• Flexible use in all typical WinCC plant configurations,
client/server, redundant systems, WebNavigator
■ Function
With the WinCC Calendar Scheduler, events and their
associated actions can be configured in a user-friendly and
clear way in an editor in WinCC Explorer.
4
• Option for SIMATIC WinCC for managing events in a calendar.
• Setting WinCC variables or starting global scripts at defined
times.
• A license is only necessary on the server
(or single user system).
The events are represented in a calendar. The period represented can be freely selected. Recurring events can be defined
as serial events with any desired exceptions.
The events are displayed in a .Net control. The Calendar
Scheduler is easy and intuitive to operate and supports drag &
drop during configuration and runtime.
■ Ordering data
Order No.
WinCC/Calendar Scheduler
• for WinCC V7.2
• for WinCC V7.0 SP3
4/116
Siemens ST 80 / ST PC · 2013
6AV6372-1DC07-2AX0
6AV6372-1DC07-0AX0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Central Archive Server (CAS)
■ Overview
Central data management, reliable, high-performance archiving
and central backup mechanisms form the basis of a Process
Historian solution: Integration in the SCADA world, data interfaces for access to archived data and analysis functions are the
component parts.
The option CAS was designed for this purpose and is used to
export the archived data of all servers in the system to a
computer and manage it. Integration of CAS in the WinCC world
means that the data remains available for the WinCC clients as
well as for the WinCC standard interfaces.
WinCC/CAS contains all licenses for the central archive server
including 1500 archive tags. The number of archive tags can be
increased to 120000 using Powerpacks or further WinCC
archives.
■ Benefits
• Central data management of all archived alarms and process
values
• Integrated back-up system for the archive data
• Transparent access to the data from all WinCC clients and
over the open interfaces
• Integrated Web viewer for analyzing data
■ Function
Both the process value archive and alarm log are created on the
separate WinCC servers and transferred to CAS when individual
database segments have been closed.
With "Store&Forward", when the network is interrupted between
the WinCC server and CAS, data will be reliably transferred as
soon as the network is operating again.
Data access is transparent for display and analysis and is still
possible through the standard WinCC clients. For the clients, it
is of no consequence whether the data are on the WinCC server
or already on CAS. Data saved in CAS can also be viewed using
the Web viewer included in the package.
The data of the distributed WinCC system can also be accessed
through the familiar interfaces (OPC DA, OPC A&E, OPC HDA
and Ole-DB) with the help of the Connectivity Pack or the
Connectivity Station. In this manner, the data saved in CAS can
be efficiently transferred to higher-level systems or used for the
purposes of analysis.
■ Ordering data
Order No.
WinCC/CAS V7.0 SP3
basic packages
• WinCC/CAS V7.0 SP3
• WinCC/CAS V7.0 SP3 ASIA
6AV6371-1DQ17-0XX0
6AV6371-1DQ17-0XV0
WinCC/CAS upgrade
• V6.2 to V7.0 SP3
• V6.2 ASIA to V7.0 SP3 ASIA
6AV6371-1DQ17-0XX3
6AV6371-1DQ17-0XV3
WinCC/CAS V6.2 SP3
basic packages
• WinCC/CAS V6.2 SP3
• WinCC/CAS V6.2 SP3 ASIA
6AV6371-1DQ16-2XX0
6AV6371-1DQ16-2XV0
4
Note:
Standard Archive Powerpacks (see WinCC ordering data) can
also be used for WinCC/Central Archive Server (CAS)
WinCC V7.2 is not supported. The successor product is the
option Process Historian for V7.2.
Siemens ST 80 / ST PC · 2013
4/117
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/ChangeControl & WinCC/Audit
■ Overview
4
■ Benefits
• WinCC/ChangeControl is used to trace engineering
changes in a tamper-proof long-term audit trail database,
called the audit trail for short. All changes are automatically
entered in the engineering system in the audit trail. This
enables all the changes to be traced that have been made, to
deduce the causes and minimize downtimes on the system.
To begin tracing at a defined project status, a project version
definition is provided that contains all data and files of a
WinCC project version. The project version definition naturally
provides the ability to reactivate earlier project versions.
Document management is also provided, which manages and
archives intermediate status for system graphics, reports or
user files and stores change information of the user. An audit
viewer with helpful filter functions can be used for quickly and
simply evaluating the audit trail, exporting it to an Excel sheet
or printing it out.
• WinCC/Audit Includes the full functionality of
WinCC/ChangeControl and is also used for tracing all
operations. All operations are automatically recorded in the
audit trail at RT.
• Licensing : To configure which change information
from the project should be recorded in the audit trail, the
WinCC/ChangeControl RC or WinCC/Audit RC package is
required. "RC" stands for Runtime and Configuration. It is
required on the station that is to be configured and also
includes an RT license. For recording an audit trail, one
WinCC/Audit RT license is required per WinCC station
(Client/Server).
• The WinCC/Audit or WinCC/ChangeControl and
SIMATIC Logon options support users in respect of plant
validation and meet the requirements of FDA CFR 21 Part 11.
A declaration of conformity (White Paper) offers proof of this.
4/118
Siemens ST 80 / ST PC · 2013
• Quick and easy traceability configuration
• Gap-free and automated recording of engineering changes
and operator actions in an audit trail
• Reduction in plant downtimes thanks to fast analysis of the
gap-free recorded audit trail information
• Logging of defined WinCC project status with all database
information and files of the application
• Gap-free documentation of the project version definition
procedures with version number, user and comments
• Complete tracing support by WinCC single and multi-station
systems, single and multi-project solutions, Client/Server
architecture
• Extensive reduction in engineering outlay in order to meet the
requirements of FDA 21 CFR Part11 & EU 178/2002
• Compliance with the requirements of the Food and Drug
Administration (FDA) for the pharmaceutical and food
industries.
■ Design
WinCC/ChangeControl and WinCC/Audit consist of five components:
• The audit editor for configuration the audit trail content
• The project version definition for logging WinCC projects
• Document management for automatic archiving and
versioning of WinCC plant mimics, scripts, reports, and
project-specific documents, and the recording of the
associated change information
• The audit viewer for visualizing, exporting and printing
WinCC and WinCC flexible audit trails. The viewer is available
as an executable program under Windows, as well as OCX
with WinCC Runtime.
• The audit trail, which tracks all changes in respect of both
engineering and plant operation in a separate SQL database.
The audit trail can be set up as a central audit trail for a
number of projects or even just for a single project.
WinCC/ChangeControl and WinCC/Audit support both singleuser and multi-user systems, client/server architectures and
even the WinCC redundancy system. No redundant audit trail is
created however.
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/ChangeControl & WinCC/Audit
■ Function
WinCC/ChangeControl
WinCC/ChangeControl is a functional subset of WinCC/Audit.
WinCC/ChangeControl is for tracing engineering changes in the
engineering phase or in online operation. All change data is
recorded in an audit trail.
There are two types of engineering changes:
• those that change the WinCC database or are executed
through the WinCC Explorer, such as e.g. changes to tag
management or creating a user group,
and those
• limited to changing files, the so-called document administration.
The document management manages system images, scripts
and log layouts and customer-specific documents and stores
respective intermediate versions as backups. All of these
documents or files are subject to a change process, i.e.
documents can be booked out for processing, booked in for
finalization and intermediate versions can be retrieved from
backup storage with a rollback function.
The project version definition as a component of
WinCC/ChangeControl archives WinCC projects and creates
reproducible project status or defined start-time points for
starting tracing. An audit trail is also provided with information on
who has created which project version or which version has
been reproduced or deleted.
Configuring the audit trail, the project version definition and the
document management is simple, quick and comfortable.
The audit trail data is visualized from WinCC, as well as from
WinCC flexible via the audit viewer, an executable program
under Windows. The data can also be evaluated with the audit
viewer OCX in Runtime by WinCC however. Users select the
desired view of the audit trail information via filters or selection
criteria and can export the data to an Excel file or print it on a
printer. Audit trail information is tamper-proof and can thus not
be modified or deleted. An export function can be used to swap
out the audit trail to an XML file or to archive it.
■ Ordering data
Order No.
WinCC/ChangeControl
For the configuration
of the audit trail incl. RT
• WinCC V7.0 SP3
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3
6AV6371-1DV27-0AX0
6AV6371-1DV26-2AX0
WinCC/Audit RC
For the configuration of the audit
trail incl. RT
• WinCC V7.0 SP3
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3
6AV6371-1DV17-0AX0
6AV6371-1DV16-2AX0
WinCC/Audit RT
Creation of audit trails in RT
• WinCC V7.0 SP3
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3
6AV6371-1DV07-0AX0
6AV6371-1DV06-2AX0
Upgrades
V6.x to V7.0
• for WinCC/Audit RT
• for WinCC/Audit RC or
WinCC/ChangeControl
6AV6371-1DV07-0BX4
6AV6371-1DV17-0BX4
V6.x to V6.2
• for WinCC/Audit RC and
WinCC/Audit RT
6AV6371-1DV06-2AX3
4
■ More information
Information about FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC to FDA21 CFR
Part 11.
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm
WinCC/Audit
WinCC/Audit has all of the functionality of WinCC/ChangeControl
and is also used for tracing user operations in RT operation.
Tracing can be used for determining who, when and what conditions the machine has undergone. In addition to recording
operator activities, the audit trail also records the starting and
modifying of recipes or user logs. At specific objects or events,
such as function buttons or sliders, the user can also record
activities of an individual nature such as e.g., pressing a function
button, moving sliders and other actions with a so-called audit
entry function in the audit trail.
A WinCC/ChangeControl RC license or a WinCC/Audit RC
license is required for configuring the audit trail. One RT license
is required for each station (client/server) to be monitored. One
RC license always includes one RT license.
Siemens ST 80 / ST PC · 2013
4/119
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Connectivity Pack &
WinCC/Connectivity Station
■ Overview
MES
Online data access
to variables
OPC DA
OPC XML DA
OPC UA DA
ERP
MES
Online messages
forward/acknowledge
OPC A&E
Online data access
to historical data
OPC HDA
OPC UA HDA
VB (.NET),
VB Script, VBA
Database access through
3rd party application
WinCC OLE-DB
SIMATIC WinCC
4
Cross-vendor communication in the automation sector has
always been of primary importance for WinCC. This is even more
true for the release of preprocessed production data for higherlevel information systems (e.g., MES = Management Execution
System, ERP = Enterprise Resource Planning or Office
packages = MS Excel, MS Access etc.). WinCC features
integrated OPC Data Access and OPC XML DA servers for
access to all online values in the system and makes open interfaces available for access to historical WinCC data.
• The Connectivity Pack includes OPC XML DA 1.00, OPC HDA
1.20 (Historical Data Access), OPC A&E 1.10 (Alarm & Events)
and a WinCC OLE-DB interface which even allows remote
computers without WinCC to access WinCC archive and
alarm data.
• The function of the OPC servers (XML DA, HDA and A&E) is
assured by the WinCC/Connectivity Pack. In order to access
data in the database via WinCC OLE-DB/OLE-DB, you will
also need a license for the WinCC/Connectivity Pack.
■ Benefits
• Access to variables, historical WinCC data, alarm data and
user archives from any computer
• Options for analyzing and evaluating process data with
specialist tools or user-defined applications
(e.g., via VisualBasic)
4/120
Siemens ST 80 / ST PC · 2013
MS SQL Server
G_ST80_XX_00066
WinCC/ConnectivityPack
• A Connectivity Pack license is required for every
WinCC system to be accessed.
• If the Connectivity Station is used, an additional Connectivity
Pack license does not have to be installed on the WinCC
systems that are accessed. The Connectivity Station functions
autonomously and does not require a WinCC installation on
the computer.
• For versions below V7.0
Access to WinCC archive and alarm data from a computer
without installed WinCC basic system license or WinCC option
via the interfaces of the Connectivity Pack or Connectivity
Station requires a WinCC/Client Access license on the client
side (see also "WinCC/Client Access License").
• Connectivity Station Option for WinCC V6.2 and higher
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Connectivity Pack &
WinCC/Connectivity Station
■ Function
As an OPC HDA server, WinCC makes historical data from the
WinCC archive system available to other applications. An OPC
HDA client (e.g. a reporting tool) can define the time interval for
the required data by entering a start and end time. OPC HDA
servers also support the generation of a variety of aggregate
functions on the server itself (e.g. standard deviation, variance,
mean values, integral values, etc.), thereby helping to relieve the
load on the network, as only preprocessed data are transmitted.
OPC A&E servers are used to forward WinCC messages (along
with all associated process values) to any client at production or
enterprise control level. Filter mechanisms and subscriptions
ensure that only selected modified data are transmitted.
Acknowledgement is of course also supported.
The WinCC OPC XML DA server makes cross-platform communication between Windows and non-Windows systems possible,
even via the Internet. This enables read and write WinCC online
values (external and internal WinCC variables) to be exchanged
with non-Siemens systems.
WinCC OLE-DB makes standardized and user-friendly access to
WinCC archive data possible (MS SQL Server 2005). In exactly
the same way as access via the OPC HDA and OPC A&E interfaces, access via the WinCC OLE DB provider makes all WinCC
archive data available along with the associated process values
and message/user texts. The WinCC OLE-DB provider also
supports analysis functions such as minimum, maximum,
message hit list, etc.
The WinCC Connectivity Station was designed as a stand-alone
gateway to WinCC server data. It supports access to WinCC
server data over the OPC channels described as well as those
for process values (not alarms) over OLE DB . Access to WinCC
data is transparent, i.e. independent of which server of a
redundant pair is active or whether data have already been
transferred to the central archive server.
Connectivity Station
If no visualization is required at a station, any Windows computer
with access to WinCC via OPC and OLE-DB can be configured
via the Connectivity Station. This permits access to WinCC
stations with server packages from a central computer without
WinCC installation. The WinCC stations can be accessed via the
following interfaces:
• OPC interfaces of the Connectivity Station
• OLE DB interface of the Connectivity Pack
The two access variants are autonomous access options with
different ranges of functions.
OPC interfaces of the Connectivity Station
The Connectivity Station provides interfaces via which you can
access the following using an OPC-Client.
• OPC-DA-Server: tags, e.g. process values
• OPC-HDA-Server: archived process values
• OPC-A&E-Server: alarms
Licensing
You require the "WinCC Connectivity Station" license in order to
utilize the OPC interfaces of the Connectivity Station on a
computer without WinCC installed.
If you only use the OPC interfaces of a WinCC installation, you
only need the "Connectivity Pack" license.
The following table shows the combinations:
New:
WinCC-independent
installation with
Connectivity Station
Standard
installation:
OPC with WinCC
OPC DA
"WinCC Connectivity
Station" license
No license required
OPC HDA
"WinCC Connectivity
Station" license
"WinCC Connectivity
Pack" license
OPC A&E
"WinCC Connectivity
Station" license
"WinCC Connectivity
Pack" license
OPC UA DA
"WinCC OPC UA HDA
Connectivity Pack"
license
The Connectivity Station is planned over NCM PC Manager or
SIMATIC Manager. In Version 7, the Connectivity Station does
not run as service.
■ Ordering data
4
Order No.
WinCC/Connectivity Pack &
WinCC/Connectivity Station
V7.2; for WinCC V7.2
Basic packages
• WinCC/Connectivity Pack V7.2 1)
• WinCC/Connectivity Station V7.2 1)
6AV6371-1DR07-2AX0
6AV6371-1DR17-2AX0
V7.0; for WinCC V7.0,
WinCC V7.0 SP1/SP2/SP3 and
WinCC V7.0 SP1/SP2/SP3 ASIA
Basic packages
• WinCC/Connectivity Pack V7.0 1)
• WinCC/Connectivity Station V7.0 1)
6AV6371-1DR07-0AX0
6AV6371-1DR17-0AX0
V6.2 SP3; for WinCC V6.2 SP3 and
WinCC V6.2 SP3 ASIA
Basic packages
• WinCC/Connectivity Pack V6.2
SP3
• WinCC/Connectivity Station V6.2
SP3
• WinCC/Connectivity Pack V6.2
SP3 ASIA
• WinCC/Connectivity Station V6.2
SP3 ASIA
Upgrade1)
• WinCC/Connectivity Pack V6.x ->
V6.2 SP3
1)
6AV6371-1DR06-2AX0
6AV6371-1DR16-2AX0
6AV6371-1DR06-2AV0
6AV6371-1DR16-2AV0
6AV6371-1DR06-2AX3
Upgrades from V6.x to V7.x are included in the WinCC V7.x upgrades
Siemens ST 80 / ST PC · 2013
4/121
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/DataMonitor
■ Overview
4
■ Benefits
• The WinCC/DataMonitor is a component of WinCC Plant
Intelligence and is used for displaying and evaluating current
process statuses and historical data on office PCs with
standard tools such as Microsoft Internet Explorer or Microsoft
Excel. The DataMonitor client is provided with current and
historic process data and alarms by a DataMonitor server.
All staff ranging from machine operators to corporate
managers can use the DataMonitor to obtain information.
• DataMonitor is a suite of Internet-capable tools:
- Process Builder - Tool for simple visualization and
navigation with WinCC screens using WinCC Web Viewer
(WinC Viewer RT) in "view only" mode
- Excel Workbooks - Protocol tool that integrates WinCC
archives and online values into MS Excel and supports
online analysis
- Published Reports - Event- or time-driven execution of Excel
or PDF reports for the output of process data and analysis
results
- Web center - Individual configuration of Internet pages and
summary of information within a portal in terms of WinCC
applications
- Trends and alarms are preconfigured Web Center pages
• DataMonitor does not require manual client installation
because it loads the required components from the
DataMonitor server
• There is no installation required on the client for the
Webcenter, Trends and Alarms functions.
• Licenses for simultaneous access by 1, 3, 10, 25 or
50 DataMonitor clients. Any combination of DataMonitor and
Web Navigator licenses can be used for an application.
• Preconfigured Web Center pages permit ad hoc entry
4/122
Siemens ST 80 / ST PC · 2013
• Information can be compiled online individually during
runtime via the Internet/intranet.
• Efficiently monitor and analyze production lines.
- Display and evaluation of current process states and
historical data on remote office PCs with standard tools such
as Microsoft Internet Explorer or Excel.
- Easy access to production data via the intranet or Internet
- Quick ascertainment of the production situation
- Use of standard products
• Easily collect and distribute information.
- Automated report creation
- No additional configuration effort through direct use of
images from the WinCC project
- No training required for standard products
- Easy exchange of configuration data
• Substantiate decisions with reports.
- Evaluation via ready-made templates for special analyses of
the business processes (e.g. reports, statistics)
- Make bottlenecks transparent
- Individual views for user and situation
- Relative and absolute timeframe for information generation
• View production status anywhere and anytime.
- Individual views of information in production
- View the process and system operation
- Historical data can be compiled online individually
Highlights
• Access to the lower-level servers when installing the
DataMonitor server on a WinCC Client with separate project
(RT128 license)
• Tag logging archive tags can be accessed by means of the
web center function without changing the WinCC configuration system.
• Installation of the DataMonitor web center function on a
WinCC file server
• Dedicated Internet pages can be created for displaying data
with the Webcenter. For this purpose, the following tools which
can be integrated in the Internet sites are available.
- Bar diagram, pie chart, trend curve display
- Process value table and statistics functions for the process
values
- Alarms, hit list for alarms
- Message text display for individual message texts, message
display, selection list of created reports
- Links to internal and external pages
- Display of graphics in converted jpg format
- Display of the WinCC process images
• The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
• Reports generated with Excel or the WinCC Report Designer
can be made available on the DataMonitor server or e-mailed
automatically to the relevant group of people based on time
intervals or triggered by events.
• Connections can be established to WinCC Runtime, the
central archive server, and the swapped-out archives
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/DataMonitor
■ Benefits (continued)
New in V7.2
• DataMonitor
- In V7.2 or higher, the upgrade license is contained in the
corresponding WinCC version
- Supports Internet Explorer V 7.0, V8.0 and V9.0, including
tabbed browsing.
- Excel reports can be generated with Microsoft Excel
version 2003 / 2007 / 2010
■ Function
• All tools are fully Internet-compatible and, therefore, support
access via any type of connection (LAN, GSM, radio, modem,
Internet, etc.).
• All popular security mechanisms such as login/password,
firewalls, encryption, etc. are supported.
• Users can combine the available tools at will. Licensing only
takes into account simultaneous access to one Web server.
• For display purposes, screens from the WinCC project can be
used or special overview displays configured. Animations,
scripts, navigation and access rights remain valid.
• The WinCC/DataMonitor has purely a display function.
• Company-wide Excel reports, which contain historical and
current process values, can be stored centrally for general
access (reports, statistics). However, local queries to meet
individual requirements can be compiled and executed
online. Plot and tabular representation are supported for
archive data already swapped out.
• Data can be automatically entered into created report
templates and distributed by e-mail or saved on the server.
• The screens are displayed in the WinCC Web Viewer or in the
Internet Explorer in the view only mode of the Web Navigator.
• Enhanced user management for the web center in order to
assign individual Internet pages and created reports to
specific user groups.
• Integrating WinCC process screens on Internet pages without
installation download
• A search function facilitates the management of connections
to the WinCC Server.
• Swapped out archives can be connected and evaluated in the
DataMonitor Web center. Expansion of the display area in the
Web center (Menu Hide function)
• Excel reports created offline can be loaded onto the
DataMonitor server and are thus made available to selected
user groups or for automatic distribution.
• Pre-made elements make the assembly of individual web
pages easier for evaluating information.
• Individual information compilation on one or more Internet
pages with the option of branching to other detail pages.
• Pre-made Internet pages for trend and alarm display enable
an ad-hoc entry to Internet data evaluation.
• An higher-level navigation feature provides a common
framework for the various tools.
■ Ordering data
Order No.
WinCC/DataMonitor V7.2 for
WinCC V7.2 and
WinCC V7.2 ASIA
• 1 client license
• 3 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses
6AV6371-1DN07-2LX0
6AV6371-1DN07-2AX0
6AV6371-1DN07-2BX0
6AV6371-1DN07-2CX0
6AV6371-1DN07-2DX0
WinCC/DataMonitor
Powerpacks V7.0
• From 1 to 3 clients
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
6AV6371-1DN07-2LA0
6AV6371-1DN07-2AB0
6AV6371-1DN07-2BC0
6AV6371-1DN07-2CD0
WinCC/DataMonitor V7.0 for
WinCC V7.0, WinCC V7.0 SP3 and
WinCC V7.0 SP3 ASIA
• 1 client license
• 3 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses
6AV6371-1DN07-0LX0
6AV6371-1DN07-0AX0
6AV6371-1DN07-0BX0
6AV6371-1DN07-0CX0
6AV6371-1DN07-0DX0
WinCC/DataMonitor
Powerpacks V7.0
• From 1 to 3 clients
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
6AV6371-1DN07-0LA0
6AV6371-1DN07-0AB0
6AV6371-1DN07-0BC0
6AV6371-1DN07-0CD0
WinCC/DataMonitor, Upgrade
• from V6.0 to V7.0
• from V6.2 to V7.0
• from V6.x to V6.2 SP3
• from V6.x ASIA to V6.2 SP3 ASIA
6AV6371-1DN07-0XX4
6AV6371-1DN07-0XX3
6AV6371-1DN06-2XX3
6AV6371-1DN06-2XV3
WinCC/DataMonitor V6.2 SP3 for
WinCC V6.2 SP3
• 1 client license
• 3 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses
6AV6371-1DN06-2LX0
6AV6371-1DN06-2AX0
6AV6371-1DN06-2BX0
6AV6371-1DN06-2CX0
6AV6371-1DN06-2DX0
WinCC/DataMonitor V6.2 SP3
ASIA for WinCC V6.2 SP3 ASIA
• 1 client license
• 3 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses
6AV6371-1DN06-2LV0
6AV6371-1DN06-2AV0
6AV6371-1DN06-2BV0
6AV6371-1DN06-2CV0
6AV6371-1DN06-2DV0
WinCC/DataMonitor,
Powerpacks V6.2
• From 1 to 3 clients
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
6AV6371-1DN06-2LA0
6AV6371-1DN06-2AB0
6AV6371-1DN06-2BC0
6AV6371-1DN06-2CD0
Siemens ST 80 / ST PC · 2013
4
4/123
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/DowntimeMonitor
■ Overview
■ Benefits
• Recording failure times, localizing causes and reasons for
failure times, and monitoring of equipment efficiency.
• Weak-point analysis in production processes and recording of
undesirable process activities.
• Basis for decision making based on performance indicators.
• Identification of the events that lead to cost-intensive failures.
• Entry point for an extended downtime analysis with upgrade
options in the MES software SIMATIC IT.
• Identification of speed and quality losses.
• Complete transparency for all machines as basis for
optimizing the plant's productivity. Faults and bottlenecks are
prevented to increase availability.
• Derivation of specific parameters (KPI - Key Performance
Indicators).
• Integration of respective display instruments (controls) in
WinCC process images.
• Can be utilized for individual machines or even complete
production plants.
• Distribution of evaluations to various people over the web.
4
The entry point to SIMATIC Plant Intelligence can be through
options for the SIMATIC WinCC process visualization system.
The WinCC/DowntimeMonitor is a component of WinCC Plant
Intelligence and is used for monitoring the efficiency and performance of individual machine modules, subsystems and
production lines. The combined elements to be monitored are
designated as equipment. Using the WinCC/DowntimeMonitor,
the machine data management software, standstill time can be
recorded and analyzed centrally in production. For individual
devices, machines or entire production lines, the specific
parameters can be determined this way. Integration into WinCC
ensures complete transparency of all machine and plant data as
a basis for optimizing the plant's productivity.
The process values are read directly from WinCC and are
connected with the respective analysis function.
• The SIMATIC WinCC DowntimeMonitor can be installed on a
WinCC single station, WinCC Server or WinCC Client with
project (RT128 license), and consists of an Engineering Client
as well as a Runtime User interface.
• All engineering operations are performed using a graphic
Engineering Client. The Engineering Client is called up from
the WinCC Explorer.
• SIMATIC WinCC DowntimeMonitor provides ActiveX control
elements. These are used for displaying the determined
parameters and the progress of the various status over a
certain time period. These controls are integrated in WinCC
process images for presenting results.
• The recorded data is stored in an online database set and can
be moved to an offline database set.
• The basic package consists of the Engineering and Runtime
software and 5 licensed equipment units. Other licenses are
available for up to 25, up to 50, 100 and up to 200 equipment
units.
4/124
Siemens ST 80 / ST PC · 2013
■ Function
• Creation of a time model by defining various time categories
as a basis for the KPI calculation for elements (equipment) to
be evaluated.
• Creation of equipment, as central components for the evaluation by dividing the system into individual groups.
• Creation of a Reason Tree for detailed display of reasons for
downtimes.
• Allocation of the system status in the controller to the time
categories and Reason Trees defined in the DowntimeMonitor.
• Storing the system status for calculating and presenting Key
Performance Indicators.
• The following pre-defined Key Performance Indicators are
available: Availability, change-over, cycle time, failure time
loss, duration, effective performance, maintenance, Mean
Time Between Assist (MTBA), Mean Time Between Failures
(MTBF), Mean Time To Assists (MTTA), Mean Time To Repair
(MTTR), failure time frequency, Overall Equipment Effectiveness (OEE), performance rate, production duration, quality
rate, speed loss, Total Efficient Equipment Performance
(TEEP), utilization.
• Integration of three new controls Gant View, KPI View, and
Table View in WinCC for the display of results for one or more
equipment units.
• The WinCC DowntimeMonitor Gant View presents the
equipment status development within a certain time period.
• The WinCC DowntimeMonitor KPI View shows the distribution
of failure times and the Key Performance Indicators in a trend,
bar, segmented bar charts or Pareto chart using historical
data.
• The WinCC DowntimeMonitor Table View shows raw data for
failure times and analyzes it in the selected time period. The
user can utilize these control elements to enter, change,
distribute or combine and comment on failure times manually.
• The controls can be displayed on intranet or Internet using the
option WinCC/Web Navigator.
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/DowntimeMonitor
■ Ordering data
WinCC/DowntimeMonitor
V7.0 SP3
for WinCC V7.0 SP3 and
WinCC V7.0 SP3 ASIA
• 5 equipment units
• 25 equipment units
• 50 equipment units
• 100 equipment units
• 200 equipment units
Order No.
Order No.
6AV6372-1DB07-0BX0
6AV6372-1DB07-0DX0
6AV6372-1DB07-0FX0
6AV6372-1DB07-0HX0
6AV6372-1DB07-0KX0
WinCC/DowntimeMonitor
V1.0 SP1
for WinCC V6.2 SP2 and
WinCC V6.2 SP2 ASIA
• 5 equipment units
• 25 equipment units
• 50 equipment units
• 100 equipment units
• 200 equipment units
6AV6372-1DB06-2BX0
6AV6372-1DB06-2DX0
6AV6372-1DB06-2FX0
6AV6372-1DB06-2HX0
6AV6372-1DB06-2KX0
WinCC/DowntimeMonitor
Powerpacks V7.0
• From 5 to 25 equipment units
• From 25 to 50 equipment units
• From 50 to 100 equipment units
• From 100 to 200 equipment units
6AV6372-1DB07-0BD0
6AV6372-1DB07-0DF0
6AV6372-1DB07-0FH0
6AV6372-1DB06-2HK0
WinCC/DowntimeMonitor
Powerpacks V1.0
• From 5 to 25 equipment units
• From 25 to 50 equipment units
• From 50 to 100 equipment units
• From 100 to 200 equipment units
6AV6372-1DB06-2BD0
6AV6372-1DB06-2DF0
6AV6372-1DB06-2FH0
6AV6372-1DB06-2HX0
WinCC/DowntimeMonitor upgrade
• V1.x to V7.0 SP3
6AV6372-1DB07-0XX4
Note
WinCC V7.2 is not supported.
4
Siemens ST 80 / ST PC · 2013
4/125
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Event Notifier
■ Overview
■ Benefits
• Simple operation, configuration and planning of notifications
thanks to handling like the Microsoft Office Calendar
• Easy configuration of the notifications including support of the
WinCC Runtime languages by connecting to the WinCC alarm
system
• Configuration of recurring events taking account of configurable public holidays, vacation periods, and maintenance
periods
• Secure operation of the plant taking account of different
authentication levels
• Clear display and intuitive operation at runtime by means of
Calendar Control
• Flexible use in all typical WinCC plant configurations, single
station, client/server, redundant systems, WebNavigator
■ Function
4
• Option for SIMATIC WinCC for notifying selected persons by
e-mail in specified time slots
• Notification depends on events occurring in the WinCC Alarm
System.
• Escalation levels, i.e. Group 2 is only notified when nobody
"on site" or from Group 1 has reacted within a specified time.
• Final notification of all persons previously notified in
connection with the specific event about the reaction that has
taken place
A license is only necessary on the server (or single user system).
The WinCC Event Notifier enables the following to be configured
in a clear and user-friendly manner via the Calendar Options
Editor in the WinCC Explorer:
• The e-mail service for sending and receiving messages
• The messages by selecting configured messages in the
WinCC Alarm System as well the setup and contents of the
message by selecting the message blocks
• Contacts by selecting predefined persons from the WinCC
user administration.
In a calendar it is then possible to select the persons to be
notified within in the opened time slot from the existing contacts.
If several persons or groups of persons are set up for the same
time slot, escalation levels can be implemented by assigning
different escalation times (= dead time before notification). The
period represented by the calendar can be freely selected.
Recurring events can be defined as serial events with any
desired exceptions.
The calendar can also be integrated as .Net Control in WinCC
screens; the appearance of the calendar controls at runtime is
configurable. Via the calendar control, you can create time slots
during runtime with contacts who should be notified upon occurrence of the configured events in the WinCC Alarm System. In
addition, the calendar control allows the creation of new
contacts by means of selection from the WinCC user
management.
The Event Notifier is easy and intuitive to operate and supports
drag & drop during configuration and runtime.
■ Ordering data
Order No.
WinCC/Event Notifier
• for WinCC V7.2
• for WinCC V7.0 SP3
4/126
Siemens ST 80 / ST PC · 2013
6AV6372-1DD07-2AX0
6AV6372-1DD07-0AX0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/IndustrialDataBridge
■ Overview
WinCC V7
WinCC Professional
SIMATIC NET OPC Server
OPC DA & OPC XML DA
Online
Data Exchange
Microsoft Office
MS Excel
File (csv)
Online
Data Storage
Microsoft Office
MS Access
Online
Data Exchange
Microsoft SQL Server
Online
Data Reading
My Oracle
My SQL
Data Export
SIMATIC WinCC
OPC DA
WinCC User Archive
• The WinCC/IndustrialDataBridge option uses standard interfaces in order to connect the automation world with the world
of IT and ensure two-way information flow. Typical examples of
such interfaces are OPC in the field of automation and SQL
database interfaces in the world of IT.
• With the SIMATIC WinCC/IndustrialDataBridge, simple
configuration/parameterization of communication connections between various data sources and data destinations can
be created. The IndustrialDataBridge can be integrated into
WinCC and can also be used in stand-alone mode
(not in conjunction with WinCC).
• For example, SIMATIC WinCC with its OPC DA server
interface is the data source and an external database is the
data destination.
- Highly flexible, thanks to support for various database
formats and standard interfaces
- Fast and secure thanks to configuration instead of
programming
G_ST80_XX_00067
WinCC/IndustrialDataBridge
MS SQL Server
OLE-DB
(Alarm-, Tag logging)
• In addition to access to WinCC variables, access to
messages, process values and user archive data
(in the WinCC database) is also supported.
• WinCC/IndustrialDataBridge can be used as stand-alone
application with its standard interfaces.
• Option from WinCC V6
• For versions below V7.0
On a computer without a license for the WinCC basic
system or a WinCC option, which is to be accessed in
read/write mode by the option WinCC/IndustrialDataBridge,
a WinCC Client Access License is required
(see also "WinCC/Client Access License").
■ Benefits
• Connecting the automation level with the IT world
• Integration of systems from different manufacturers via a host
of standard interfaces (including OPC, OLE-DB, Office
formats)
• Simple configuration with standard software without
programming and thus at low cost
• High-performance data transfer between several systems
simultaneously
■ Design
The software comprises a configuration environment and a
runtime environment. The different data interfaces are integrated
via software modules. In each case, one module is required as
the data source and one module as the data destination. The
different modules can be combined in any way.
The connections between data source and data destination are
created in the configuration environment.
In the runtime environment, the IndustrialDataBridge establishes
the connection autonomously and transfers the data of the linked
variables.
Siemens ST 80 / ST PC · 2013
4/127
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/IndustrialDataBridge
■ Function
4
Interfaces:
• IndustrialDataBridge establishes a link between the source
and destination interfaces and transfers data on the basis of a
change in value, once a configurable period of time has
elapsed or when a specific event occurs.
• IndustrialDataBridge exchanges data between automation
systems from different vendors, e.g., via OPC. The connection
of OPC servers via IndustrialDataBridge enables communication between a variety of devices, data sources and data
destinations. The OPC international interface standard is the
key to open systems both now and in the future. Thanks to
IndustrialDataBridge, OPC data exchange can already be
supported.
• WinCC supports access to variables, tag logging, alarm
logging and user archive data.
• Storage of process data in Office formats such as Excel or
Access. Databases can also be integrated for the archiving of
larger aggregates.
• One of the features of IndustrialDataBridge is a Send/Receive
interface supporting data transfer to SIMATIC S5/S7 stations
or other Send/Receive-compatible devices.
• IndustrialDataBridge enables SCADA and control systems
from different vendors to be linked via the OPC interface.
Communication via RFC1006 or Send/Receive is also
supported.
• SQL databases are available as data destinations for
production data acquisition. Data can be transferred from the
data source on an event-driven basis with the OPC module or
sent directly from the PLC with the Send/Receive module.
• Cyclic data archiving can be implemented via the OPC Data
Access, WinAC ODK or Send/Receive data sources and the
SQL database data destinations. On the database side,
various transmission mechanisms are supported.
• Individual control during runtime for each
IndustrialDataBridge connection
(start, stop, connect, and disconnect).
• Integration of IndustrialDataBridge runtime control in
WinCC screens if IDB is installed on a WinCC station.
• Independent CSV files are created if a configurable number of
entries is reached or the value of a WinCC tag changes.
• Block transfer for databases through support for the operators
"<" and ">" in the Select instruction.
• Available providers (data sources) can be connected to any
consumers (data destinations) (see table, below)
New functions in Version 7.2:
• Faster configuration due to new configuration interface
• OPC XML DA Provider / Consumer (data exchange via the
Internet using HTTP and SOAP)
• Support for Asian languages (Simplified Chinese, Japanese)
• Unicode support
• Getting Started for data exchange between User Archive and
Microsoft Access
• For installation in combination with the WebNavigator Server,
the IndustrialDataBridge can be controlled via the Internet
4/128
Siemens ST 80 / ST PC · 2013
The table below shows the possible data sources and destinations
Provider (data sources)
Consumer (data destinations)
• MS Access 2003, 2007, 2010
• CSV, TXT
• MS SQL server 2005, 2008,
2008 R2
• MS Access 2003, 2007, 2010
• MySQL ODBC 3, 5, 5.1, 5.5
• MySQL ODBC 3, 5, 5.1, 5.5
• Oracle 8i, 10g, 11g
• Oracle 8i, 19g, 11g
• OPC Data Access 3.0,
OPC XML 1.0
• MS Excel
• Send / Receive
• MS SQL server
• OPC Data Access Server (internal)
• WinCC OLE DB V7.2
• OPC Data Access 3.0,
OPC XML 1.0
• WinCC User Archive V7.2
• Send / Receive
• WinCC User Archive V7.2
■ Ordering data
Order No.
WinCC/IndustrialDataBridge
V7.2, option for WinCC V7.2
For data exchange with databases
and OPC servers; language
versions: German, English, Chinese
simplified, Japanese
• with 128 tags
• with 512 tags
• with 2048 tags
• with 10000 tags
6AV6371-1DX07-2AX0
6AV6371-1DX07-2BX0
6AV6371-1DX07-2CX0
6AV6371-1DX07-2DX0
V7.0 SP1, option for WinCC V7.0
SP3
For data exchange with databases
and OPC servers; language
versions: German/English
• with 128 tags
• with 512 tags
• with 2048 tags
• with 10000 tags
6AV6371-1DX07-0AX0
6AV6371-1DX07-0BX0
6AV6371-1DX07-0CX0
6AV6371-1DX07-0DX0
WinCC/IndustrialDataBridge
Powerpack V7.2
• from 128 to 512 tags
• from 512 to 2048 tags
• from 2048 to 10000 tags
6AV6371-1DX07-2AB0
6AV6371-1DX07-2BC0
6AV6371-1DX07-2CD0
WinCC/IndustrialDataBridge
Powerpack V7.0
• from 128 to 512 tags
• from 512 to 2048 tags
• from 2048 to 10000 tags
6AV6371-1DX07-0AB0
6AV6371-1DX07-0BC0
6AV6371-1DX07-0CD0
WinCC/IndustrialDataBridge
upgrade
• from V7.0 to V7.2
• from V6.x to V7.2
• from V6.x to V7.0 SP3
6AV6371-1DX07-2XX3
6AV6371-1DX07-2XX4
6AV6371-1DX07-0XX4
WinCC/IndustrialDataBridge
V6.1, option for WinCC V6. 2
For data exchange with databases
and OPC servers; language
versions: English/German
• with 128 tags
• with 512 tags
• with 2048 tags
• with 10000 tags
6AV6371-1DX06-1AX0
6AV6371-1DX06-1BX0
6AV6371-1DX06-1CX0
6AV6371-1DX06-1DX0
WinCC/IndustrialDataBridge
Powerpack V6.1
• from 128 to 512 tags
• from 128 to 2048 tags
• from 128 to 10000 tags
• from 512 to 2048 tags
• from 512 to 10000 tags
• from 2048 to 10000 tags
6AV6371-1DX06-1AB0
6AV6371-1DX06-1AC0
6AV6371-1DX06-1AD0
6AV6371-1DX06-1BC0
6AV6371-1DX06-1BD0
6AV6371-1DX06-1CD0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/IndustrialX
■ Overview
■ Benefits
• Easy creation using configuration wizards
• Quick entry due to the use of standards: ActiveX technology,
creating with the aid of Visual Basic
• Central creating and changing of object displays of the same
type (typing) saves time and money
• Configuring of intelligent, sector-specific objects (graphic
illustration and logical processing) with know-how protection
• Can be used in versatile ways: in WinCC screens and other
Windows applications (e.g. Internet Explorer, Excel)
Innovations of V7.0
Support of Visual Studio 2005 (.NET)
■ Application
IndustrialX controls create standardized presentations and allow
flexible customization to the requirements of a wide range of
applications, e.g. applications in the chemical, glass or paper
manufacturing industries.
• WinCC/IndustrialX makes it easier to develop a solution for a
visualization task by allowing customized objects to be
standardized
• A license must be installed on each development computer
(current version of Visual Basic must be installed on the development computer)
■ Function
• Configuring intelligent, industry-specific objects (graphic
illustration and logical processing) with know-how protection
• Automatic object supply with WinCC data structures
(templates)
• Creation of Web Navigator-compatible, customer-specific
ActiveX components with active process data supply
• Integration into WinCC via structure names
■ Ordering data
Order No.
WinCC/IndustrialX
• V7.0; for WinCC V7.0 and V6.x
6AV6371-1EL17-0AX0
Note
For WinCC V7.2, the WinCC/IndustrialX option is part of the
WinCC/ODK option.
Siemens ST 80 / ST PC · 2013
4/129
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Open Development Kit (ODK)
■ Overview
■ Function
WinCC/ODK (Open Development Kit)
• WinCC option for utilization of the exposed programming interfaces that can be used to access data and functions of the
WinCC configuration and WinCC runtime system
• The interfaces are designed as "C-Application Programming
Interface" (C-API)
• Scope of delivery:
- CD-ROM with examples
- Voucher for a one-day intensive workshop
■ Benefits
• Individual system expansions via an open standard
programming language
• Access to data and functions of the WinCC configuration and
runtime system
• Development of your own applications and add-ons for the
WinCC basic system
New in V7.0
• Support for Visual Studio 2005 (.NET)
4
New in V7.2
• UNICODE support
• Support for Visual Studio 2008, 2012
4/130
Siemens ST 80 / ST PC · 2013
The API functions are configuration and runtime functions, and
include:
• MSRTCreateMsg: Creates a message
• DMGetValue: Gets the value of a variable
• PDLRTSetProp: Sets the object properties in a display
They can be used in the following places:
• within WinCC, for example in global scripts or as part of C
actions in the Graphics Designer,
• in Windows applications in the programming language C
(the current version of Microsoft Visual C++ is necessary as a
development environment for WinCC).
■ Ordering data
WinCC/ODK
• V7.2; for WinCC V7.x
• V7.0; for WinCC V7.0 and V6.x
Order No.
6AV6371-1CC07-2AX0
6AV6371-1CC07-0AX0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/ProAgent
■ Overview
■ Ordering data
Order No.
SIMATIC WinCC/ProAgent
• V7.2; for WinCC V7.2
• V7.0 SP3; for WinCC V7.0 SP3
SIMATIC WinCC/ProAgent
Upgrade
• to SIMATIC WinCC/ProAgent V7.2
• to SIMATIC WinCC/ProAgent V7.0
SP3
6AV6371-1DG07-2AX0
6AV6371-1DG07-0AX0
6AV6371-1DG07-2AX3
6AV6371-1DG07-0AX4
3B67B;;B
67(3
• Precise and rapid process fault diagnostics in plants and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various
SIMATIC components
• No further configuration for diagnostics functionality
• Reduces PLC memory and processor usage
4
Note
For further details, see "SIMATIC ProAgent process diagnostics
software"
Siemens ST 80 / ST PC · 2013
4/131
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Redundancy
■ Overview
• Option for SIMATIC WinCC, supporting the parallel operation
of two interfaced WinCC single-user systems or process data
servers for mutual monitoring
• If one of the two server PCs or one of the two WinCC stations
fails, the second one will take over control of the entire system.
Once the failed server or station is restored to operation, the
content of all the message and process value archives are
copied to it.
• One WinCC/Redundancy package is required for each
redundant pair of servers.
~•jj
j“Œ•›š
shu
■ Benefits
~•jj
zŒ™Œ™š
wyvmpul{
G_ST80_XX_00082
wyvmpi|z
■ Function
Normally, two WinCC stations or process data servers run in
parallel. Each station has its own process connection and its
own data archives. WinCC/Redundancy ensures automatic
matching of system and user archive data.
~•jj
j“Œ•›š
4
• Increased system availability with continuous data integrity
• Automatic changeover of client in the event of failure of a
server or failure of the communication to a server
• Continuous operator control and visualization thanks to
automatic client changeover to the intact server
• Automatic updating of all archives in the background after
rectification of the fault
If one of the two server computers or WinCC stations fails, the
second will take over the archiving of messages and process
data, thereby ensuring seamless data integrity. In client/server
mode, the clients are automatically switched from the failed
server to the redundant partner. This ensures continuous plant
visualization and operation on every operator station.
shu
~•jj
zŒ™Œ™š
When the failed partner resumes operation, all process values,
messages and data archived during the fail period are automatically matched with the partner. This process runs in the
background and does not affect plant continuity. Once this is
complete, two equivalent servers/stations will be available
again.
wyvmpul{
G_ST80_XX_00083
wyvmpi|z
Communication with the SIMATIC S7 can also be configured with
redundancy (an H Series SIMATIC S7 is required) by plugging in
two communication modules and configuring two communication paths (S7-REDCONNECT software package). The use of
failsafe H Series SIMATIC S7 can, if required, further increase
availability at control level.
■ Ordering data
~•jj
j“Œ•›š
SIMATIC WinCC/Redundancy
• Option for SIMATIC WinCC V7.2,
Runtime software, single license
for 2 installations
• Option for SIMATIC WinCC V7.0,
Runtime software, single license
for 2 installations
• Option for SIMATIC WinCC V6.2,
Single license for 2 installations
shu
~•jj
zŒ™Œ™š
wyvmpul{
G_ST80_XX_00084
wyvmpi|z
4/132
Siemens ST 80 / ST PC · 2013
Order No.
6AV6371-1CF07-2AX0
6AV6371-1CF07-0AX0
6AV6371-1CF06-2AX0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Server
■ Overview
WinCC Client
WinCC Client
WinCC Client
TERMINAL BUS TCP/IP
PROCESS BUS
G_ST80_XX_00005
WinCC Server
• Option for SIMATIC WinCC, which permits the configuration of
a powerful client/server system
• One of the following operating systems must be available to
install the option on the server: Windows Server 2003 (for V6)
or Windows Server 2003 R2 (for V6.2 / V7.0 / V7.2) or Windows
Server 2008 (for V7.0 with SP2 and higher or V7.2). When
using Windows XP Professional and Windows 7 SP1, no more
than 3 clients can be connected.
• A number of coordinated HMI stations can be operated in a
single group with networked automation systems
• Client/server solution:
- One server can supply up to 32 connected clients with
process and archive data, messages, images and reports
- Depending on the size of the plant, up to 12 servers
(or up to 18 in version 7.2 or higher) can be used.
- 32 clients (max. 12 or 18 redundant WinCC servers) possible
per system
• Requirement:
Network connection (TCP/IP) between the server PC and the
connected clients. 1)
• One license is required for each server.
1)
One of the following operating systems is installed on one WinCC server:
Windows Server 2003, Windows Server 2003 R2 or Windows Server 2008.
Max. 3 clients with Windows XP Professional and Windows 7 SP1.
■ Benefits
• Plant-wide scalability from the single-user system to the
client/server solution
• Significantly higher quantity framework, relieving the
individual servers and better performance due to distributing
the complete application or tasks over several servers
• Low-cost configuration on the client is possible
(the minimum RC license is sufficient)
4
■ Application
In a complex plant, WinCC can also be configured as a
distributed system according to requirements:
• Functional distribution (e.g. message servers, archive
servers, etc.) or
• Distribution according to the physical plant structure
(e.g. body-in-white, paintshop, etc.)
■ Function
Each client can access more than one server at a time. Clients
can also be used for configuration on the server.
A configuration of WinCC clients as a central Web server - as a
distributed system if required - with an overview of all server
projects in the system is also possible.
For WinCC clients, only the smallest runtime license RT128 is
required. In order to also configure on WinCC clients, the
smallest complete license RC128 is required. Remote configuration is possible if WinCC clients without their own project
(Uniclients) on the server project are configured. This makes it
possible to configure inexpensive operator and configuration
stations in a network.
■ Ordering data
Order No.
SIMATIC WinCC/Server
• Option for SIMATIC WinCC V7.2,
Runtime software, single license
• Option for SIMATIC WinCC V7.0,
Runtime software, single license
• Option for SIMATIC WinCC V6.2,
Single license
6AV6371-1CA07-2AX0
6AV6371-1CA07-0AX0
6AV6371-1CA06-2AX0
Siemens ST 80 / ST PC · 2013
4/133
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/TeleControl
■ Overview
WinCC/TeleControl for WinCC V7.0 SP2 supports connection to
outlying stations (Remote Terminal Units = RTUs) via telecontrol
protocols.
■ Benefits
WinCC/TeleControl for WinCC V7.0 SP2 cannot only integrate
newly configured RTUs, it can also integrate units which already
exist in outlying areas by means of DNP3 or IEC 870-5-101/104
drivers.
For communication with the outstations, WinCC/TeleControl for
WinCC V7.0 SP2 uses the SINAUT ST7 and DNP3 protocols
(both via serial and TCP/IP communication connections) as well
as IEC 870-5-101 (serial) and IEC 870-5-104 (Ethernet TCP/IP).
The serial RTU link is possible via the following components,
which can be connected directly via WinCC (single station or
server):
• SINAUT TIM communication modules
(SINAUT ST7 telecontrol protocol)
• TCP/IP serial converter (telecontrol protocols DNP3, Modbus
(not released for WinCC TC), IEC 870-5-101)
Equipment from MOXA or Lantronix, for example, can be used
as TCP/IP serial converters.
4
By means of Ethernet TCP/IP, the RTUs can be connected
directly or via TCP/IP WAN routers to the SIMATIC WinCC system
bus (SINAUT ST7, DNP3, IEC 870-5-104 telecontrol protocols).
When using the SINAUT ST7 telecontrol protocol, the SINAUT
TIM communication module can be used in addition to the
TCP/IP WAN router or as an alternative.
■ Application
Telecontrol communication over the wide area network is largely
determined by the communication infrastructure which already
exists. Various transmission media such as dedicated line,
analog or digital telephone networks, wireless networks (GSM or
private), DSL or GPRS can also be combined with each other.
SINAUT ST7 telecontrol protocol
Detailed information for implementing telecontrol applications
with the SINAUT ST 7 telecontrol protocol via the Industry Mall.
IEC 870-5-101/-104 telecontrol protocols
Detailed information for implementing telecontrol applications
with the IEC 870-5-101/-104 telecontrol protocols via the
Industry Mall.
DNP3 telecontrol protocol
WinCC/TeleControl for WinCC V7.0 SP2 also supports the DNP3
telecontrol protocol. Widely distributed outstations (RTUs) can
be controlled and monitored with the DNP3 telecontrol protocol
via serial or Ethernet TCP/IP communication links by means of
the telecontrol center in SIMATIC WinCC. The control center
integrated with SIMATIC WinCC TeleControl into the SCADA
system is the master during telecontrol communication. The
slaves are represented by the outstations. SIMATIC S7-300/
S7-300F and S7-400/S7-400F/S7-400H/S7-400FH controllers
as well as third-party RTUs can be used as outstations.
4/134
Siemens ST 80 / ST PC · 2013
Further hardware and software components round off the range
of products:
• TIM communication modules
• TCP/IP converters – serial and MD modem modules
• GSM/GPRS components
• TCP/IP routers and switches
• SCALANCE S612 and S613 security modules
• Dedicated-line accessories
• Connecting cables and cables
• Engineering package for configuration of DNP3 data objects,
stations, networks and connections as well as for diagnostics
In order to implement telecontrol networks, basic topologies
including point-to-point, multi-point, star and ring can be
configured using classic or TCP/IP-based media. These can be
combined flexibly independent from existing infrastructure.
Classic WAN media:
• Dedicated line via modem, e.g. SINAUT MD2
• Private wireless networks
• Analog telephone network
• Digital ISDN network
• Mobile radio network GSM
TCP/IP-based WAN media:
• Ethernet networks, e.g. SCALANCE X with fiber-optic cables
• Industrial Wireless LAN with SCALANCE W
• Public networks and the Internet using DSL and/or GPRS
■ Function
Special characteristics of DNP3 communication
• Change-driven data transmission
- Change-driven transmission of process data between RTU
and control center
- Signaling of RTU, control center or connection failure
- Automatic data updating for all communication partners
involved following troubleshooting and following the startup
of the RTU or control center
• Chronological processing of process data
- Time tagging of all data frames at the place of origin allows
process data to be archived by the process control system
in the correct chronological order
- The time of the DNP3 stations in the WAN can be synchronized via SIMATIC WinCC (including summertime/wintertime
switchover)
• Local data storage
- The TIM communication module can temporarily store
(for several hours or even days) message frames should the
connection or the communication partner fail
- Intermediate storage of message frames of lower priority in
the case of priority-controlled data transmission (with dial-up
networks or quantity-dependent data transmission costs)
Operating modes
The DNP3 telecontrol protocol supports the following operating
modes:
• Polling
• Polling with time slot procedure
• Multi-master polling with time slot procedure
• Spontaneous mode in dial-up networks
• Spontaneous mode in the TCP/IP-based WAN
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/TeleControl
■ Integration
Integration of WinCC/TeleControl for WinCC V7.0 SP2 into the
WinCC SCADA system offers particular advantages for the water
and waste water sectors, as well as oil and gas sectors,
especially in the case of the following types of plant:
• Freshwater treatment and distribution
• Wastewater treatment plants
• Oil and gas pipelines and water pipes
• Oil and gas drilling fields and the associated treatment plants
In these types of plant, remote outstations such as pumping
stations, valve stations or automated stations for wellheads must
be integrated.
Through the support of communication protocols for RTUs such
as SINAUT ST7, WinCC/TeleControl for WinCC V7.0 SP2
supports the following advanced communication concepts:
• Reduction in the transferred data volume by means of eventcontrolled communication mechanisms for alarm and
measured value information.
• Time-synchronization of RTUs and correct time stamping of all
data in the RTU.
• Tolerance of lower bandwidth, high latency or lack of reliability
of communication lines
• Prevention of data loss due to communications failure through
data backup in the RTU
• Support of communication media with serial interface
(dedicated lines, dial-up connections over analog telephone
lines and ISDN lines), various radio devices (standard, spread
spectrum modulation), microwave and GSM
• Support for TCP/IP-based WANs (Wide Area Networks) such
as DSL, GPRS or Ethernet radio networks
• Support for redundant communication connections
• Expanded communication diagnostics functions for RTU
communication links
• Remote programming of RTUs
• Support for different communication topologies –
point-to-point, multidrop (multistation mode) and hierarchic
network structures
• High quality server redundancy scheme without data loss in
the case of server failure
Through the support of communication protocols for RTUs such
as IEC 60870-5 and DNP3, SIMATIC TeleControl for WinCC V7.0
SP2 supports the following advanced communication concepts:
• Reduction in the transferred data volume by means of eventcontrolled communication mechanisms for alarm and
measured value information.
• Time synchronization of RTUs and correct time stamping of all
data in the RTU.
• Tolerance of lower bandwidth, high latency or lack of reliability
of communication lines
• Prevention of data loss due to communications failure through
data backup in the RTU (not all non-Siemens RTUs support
this)
• Support of communication media with serial interface
(dedicated lines, dial-up connections over analog telephone
lines and ISDN lines), various radio devices (standard, spread
spectrum modulation), microwave and GSM
• Support for TCP/IP-based WANs (Wide Area Networks) such
as DSL, GPRS or Ethernet radio networks
• Support for redundant communication connections
• Expanded communication diagnostics functions for RTU
communication links
• Remote programming of RTUs
• Support for different communication topologies – Point-topoint, multidrop (multistation mode) and hierarchic network
structures
• High quality server redundancy scheme without data loss in
the case of server failure
Outstations/remote terminal units
WinCC/TeleControl for WinCC V7.0 SP2 supports the following
preferred outstations for local distributed automation:
• Controller integrated into ET 200S (IEC 870-5-101/104
telecontrol protocols); for cost-sensitive applications, up to
approx. 30 I/O signals or approx. 200 data points
• S7-300/S7-300F controller (SINAUT ST7, DNP3,
IEC 870-5-101/104 telecontrol protocols); for extremely
flexible configuration, up to 100 I/O signals or
approx. 2000 data points
• S7-400/S7-400F controller (SINAUT ST7, DNP3,
IEC 870-5-101/104 telecontrol protocols);
up to 500 I/O signals or approx. 5000 data points
• S7-400/S7-400F redundant controller (IEC 870-5-101/104 and
DNP3 telecontrol protocols); up to 500 I/O signals or approx.
5000 data points
• Third-party station with the IEC 870-5-101/104 and DNP3
telecontrol protocols (depending on type of station)
Siemens ST 80 / ST PC · 2013
4/135
4
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/TeleControl
■ Integration (continued)
The following table provides an overview of the current options
for connecting to these outstations:
Spectrum of outstations and integration versions
Telecontrol protocol
SINAUT ST 7
IEC 870-5-01
IEC 870-5-04
Type of communication
Serial
Ethernet TCP/IP
Serial
Ethernet TCP/IP
Serial
Ethernet TCP/IP
Interface
TIM 4R-IE
TCP/IP WAN
router or/and
TIM 4R-IE
TCP/IP
serial converter
TCP/IP WAN
router
TCP/IP
serial converter
TCP/IP WAN router
ET 200S with
integr. CPU
(corresponding
to S7-314)
-
-
-
-
IM 151-7 CPU or
IM 151-8 PN/DP
CPU
as well as
1 SI module +
SIPLUS RIC library
IM 151-8 PN/DP
CPU
+ SIPLUS RIC
library
S7-300/S7-300F
TIM 3V-IE
TIM 3V-IE
TIM 3V-IE DNP3
TIM 3V-IE DNP3
CP 341
+ SIPLUS RIC
library
CP 343 + IEC on
S7 or integr. PN
interface
+ SIPLUS RIC
library
S7-400/S7-400F
TIM 4R-IE
TIM 4R-IE
TIM 4R-IE DNP3
TIM 4R-IE DNP3
CP 441
+ SIPLUS RIC
library
CP 443 + SIPLUS
RIC library or
integr. PN interface
+ SIPLUS RIC
library
S7-400H/
S7-400FH
-
-
TIM 4R-IE DNP3
TIM 4R-IE DNP3
ET 200M + 2 x CP
341 + SIPLUS RIC
library
CP 443
+ SIPLUS RIC
library
Third-party
station
-
-
Depends on type of station
Depends on type of station
RTU/interface
4
DNP3
Dial-up lines
•
-
•
-
-
-
Dedicated line and
radio networks
•
•
•
•
•
•
Master/slave
•
•
•
•
•
•
Peer-to-peer
•
•
-
-
•
•
Mesh networks
•
•
•
•
•
•
Time tagging in RTU
•
•
•
•
•
•
RTU time synchronization
•
•
•
•
•
•
Data buffering in RTU
•
•
•
•
• 1)
• 1)
Routing with SIMATIC PDM
•
•
-
-
-
•
International standard
-
-
•
•
•
•
1)
Data buffering is limited to two SIMATIC S7 data blocks. Depending on the
SIMATIC CPU, this corresponds to approx. 800 to 3200 buffered frames.
4/136
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/TeleControl
■ Ordering data
SIMATIC TeleControl 7.0 SP2
for WinCC Basic Engineering
Order No.
6DL5000-7AA07-0XA5
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Engineering Software,
2 languages (English, German),
executable with Windows XP
Professional/Server 2003, Floating
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick, Certificate
of License incl. terms and conditions,
SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC
TeleControl Option V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (6 stations)
6DL5002-7AA07-0XA0
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime Software, 2 languages
(English, German), executable with
Windows Server 2003, Single
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl.
Terms and Conditions, SIMATIC
WinCC Data Medium Package V7.0
+ SP2 and CD "WinCC TeleControl
Option V7.0 + SP2"
6DL5101-8AX00-0XB0
Runtime license for one
WinCC Single Station or one
WinCC server, Single License
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions
TeleControl DNP3 Driver
6DL5002-7AB07-0XA0
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime software, 2 languages
(English, German), executable with
Windows Server 2003, single
license for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions, SIMATIC WinCC
Data Medium Package V7.0 + SP2
and CD "WinCC TeleControl Option
V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (256 stations)
6DL5002-7AF07-0XA0
Driver software
for telecontrol protocols
TeleControl SINAUT Driver
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime Software, 2 languages
(English, German), executable with
Windows Server 2003, Single
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions, SIMATIC WinCC
Data Medium Package V7.0 + SP2
and CD "WinCC TeleControl Option
V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (12 stations)
Order No.
SIMATIC TeleControl 7.0 SP2
for Server Runtime
(unlimited stations)
6DL5101-8EX00-0XB0
Runtime license for one
WinCC Single Station or one
WinCC server, single license
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for
WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions
TeleControl IEC 870-5-101/-104
Driver
6DL5002-7AE07-0XA0
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime software, 2 languages
(English, German), executable with
Windows Server 2003, single license
for one user; electronic documentation
on CD/DVD, 2 languages
(English, German)
Type of delivery:
License key memory stick, Certificate
of License incl. terms and conditions,
SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC
TeleControl Option V7.0 + SP2"
4
6DL5101-8CX00-0XB0
Runtime license for one
WinCC Single Station or one
WinCC server, single license
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for
WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions
■ More information
For an overview of the complete performance spectrum on the
Internet, visit:
Service & Support:
http://www.siemens.com/automation/csi_en_WW/service
(international)
Technical Support (hotline) for Automation & Drives:
http://www.siemens.com/automation/csi_en_WW/
support_request
(international)
Siemens ST 80 / ST PC · 2013
4/137
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/User Archives
■ Overview
■ Function
• Input of parameter sets (e.g. operating parameters of a
machine) in WinCC, storage of the sets in the user archive,
and forwarding to the automation level
• Continuous acquisition of production parameters by the
automation system and forwarding of the parameters to
WinCC at the end of the shift
• Acquisition of batch data
• Specification of production parameters
• Management of warehousing data
WinCC user archives are created and assigned data in a userfriendly way using a dedicated editor. Special ActiveX controls
are used for displaying data from the user archives at runtime.
Data sets and fields from user archives are linked to the process
via direct tag linking.
4
• Option for SIMATIC WinCC for managing data sets in user
archives that contain related data.
• WinCC and its automation partners (e.g. a SIMATIC S7
controller) write these data sets and exchange them if
required.
• A license is only required for the server
(or single-user system).
The WinCC/User Archives option can also be used in the context
of the WinCC/Web Navigator (see also WinCC/Web Navigator
option).
■ Benefits
• Storing and managing of any user data in data sets
• Flexible display using ActiveX controls
• Simple linking of data set fields to the process via direct tag
linking
• Import/export functions for further processing with other tools
(e.g. MS Excel)
4/138
Siemens ST 80 / ST PC · 2013
Import and export functions support read-in/out of data via
external applications (e.g. MS Excel). Freely selectable filter
criteria allow clear representation of data sets.
WinCC provides functions for free organization of the data
storage in the user archives that affect archives, data sets and
fields. Archives can thus be generated, opened, closed, or
reset, and data sets or field contents can be read, written or
overwritten.
Sequence archives can accommodate batch data, shift
production data, or also product quality data, and meet legal
obligations for verification thanks to gap-free recording.
■ Ordering data
SIMATIC WinCC/User Archives
• Option for SIMATIC WinCC V7.2,
Runtime software, single license
• Option for SIMATIC WinCC V7.0,
Runtime software, single license
• Option for SIMATIC WinCC V6.2,
Single license
Order No.
6AV6371-1CB07-2AX0
6AV6371-1CB07-0AX0
6AV6371-1CB06-2AX0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
■ Overview
WinCC
Web client
WinCC
DataMonitor
Internet
WinCC
SCADA client
+ Web server
WinCC
SCADA clients
WinCC
Web client
WinCC
DataMonitor
LAN
WinCC server
(max. 18)
4
PROFINET
G_ST80_XX_00021
PROFIBUS
• Option for SIMATIC WinCC for operator control and monitoring
of plants via the Internet, in-house intranet or LAN
• Configuration from:
- a Web server with the SIMATIC WinCC software as a singleuser, client or server version and a Web client that enables
operator control and monitoring of a current WinCC project
via an Internet browser with ActiveX support. The WinCC
basic system does not have to be installed on the client
computer. It is also possible to use the Web client without
Microsoft Internet Explorer.
• Licensing:
- A license is required in order to use the Web server.
- Licenses are available for access to the Web server
by 1, 3, 5, 10, 25, 50, 100 or 150 clients.
- Low-priced WebNavigator diagnostics licenses are
available for the remote diagnostics via multiple, distributed
Web servers.
Siemens ST 80 / ST PC · 2013
4/139
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
■ Overview (continued)
4
Highlights:
• Installation of the Web server - in distributed systems - also on
a WinCC Client;
- Access to as many as 18 subordinate WinCC stations
(servers) possible
- Web clients offer common views of data on various
WinCC Servers
- If you are using WinCC/Redundancy, the Web clients will
also transfer via the subordinate WinCC servers (requires
WebNavigator server to be installed on the WinCC Client
(RT128) )
- Separating the Web functionality from the WinCC data
servers makes the overall system safer and more scalable in
respect of load. Integrated user management with WinCC:
The configured WinCC operator authorizations are taken into
account on the Web client.
• Access to WebNavigator server from the WebNavigator
TIA Portal series of products.
• Access to user archives.
• VB scripts are supported in the same way as the new objects
and RT functions in WinCC V7.x.
• User-friendly services and tools for distributing customized
objects (controls, files) to Web clients can be supplied for use
as an integration platform. These components can then also
be integrated into cross-Web/Server navigation.
• Distribution of load across a number of Web servers in order
to run several hundred Web clients in a single system; Web
clients are distributed across Web servers automatically.
• Version 7.2 supports Microsoft Internet Explorer Version 8.0
and 9.0, including tabbed browsing. A new license is not
required for separate tabs.
• With the WinCC Web Viewer, the process screens can be
displayed on the Web client independently of the Internet
Explorer. Settings for the client are made on the client itself.
• The WinCC Web Viewer can also be used in conjunction with
the Microsoft Terminal Service.
• From version 7 on, the WebNavigator can also be operated in
"view only" mode and is thus used as tool for operating and
navigating only via WinCC screens by means of the Internet
Explorer.
• The cursor for View only mode can be selected according to
individual requirements.
• Web server logins and logouts are recorded in the alarm and
audit archive.
• There is a gadget available for the Windows 7 operating
system in which selected WinCC process screens can be
displayed. The gadget does not require any additional
WebNavigator license. The WebNavigator server can be
selected direct using the gadget.
• Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
• Runtime in the Web client can be terminated by means of
scripting.
4/140
Siemens ST 80 / ST PC · 2013
■ Benefits
• Operator control and monitoring across long distances and on
different platforms (PC, local panel, mobile PDA)
• Large configurations with up to 150 operator stations
• Fast updating rates thanks to event-driven communication
• Optimally tailored clients for operating and monitoring,
analysis, service and diagnostics
• Acceptance of configuration data for the Web, generally
without changes
• Minimum maintenance costs thanks to centralized software
administration
• High security standards and availability
- Increased security due to separation of WinCC server and
Web server (Web server in secure environment)
- Support for commonly used security mechanisms
(routers, firewalls, proxy servers)
- Access authorization and user administration
New in V7.2
• New license stages for 1, 5, 100, 150 clients and associated
powerpacks 1/3, 3/5, 50/100, 100/150
• Unicode support
• PDL password protection with WebNavigator PDLPad
• Login / logout / register:
• Log user in/out on the WebNavigator client
• Manual logout in the Internet Explorer by means of
ODK C-Script (PWRTLogout function)
• Configurable logout/login in the WinCC RT Viewer
■ Application
In addition to the typical use of the Web Navigator in WANs
(Wide Area Network), the Web Navigator is also suitable for
solving especially low-cost applications. This especially
includes applications that have a pronounced distributed
structure (water/wastewater, oil & gas), or in which access to
process information is only sporadic (building management).
The Web Navigator also permits vertical integration, i.e. a
networked IT landscape with integrated data flow between the
planning and operating levels within a company. Only a
standard browser is required for direct access to current
process information.
The Web Server can have its own dedicated direct process
connection. An alternative is coupling via OPC or the use of a
remote Web Server to a WinCC Client. This simultaneously
increases security and reduces the communication load of the
plant.
In addition to the Standard Web Navigator licensing there is the
so-called Diagnostics Client, with identical functions in principle,
but which is especially suitable for the following applications:
• Remote diagnostics/operation of several unmanned
WinCC stations.
• Central control rooms which monitor multiple Web Servers on
one user interface.
• Power Users that always require guaranteed access to the
server regardless of the number of users already logged on to
the server.
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
■ Design
Licenses for the Web Navigator
The Web Navigator Client software can be installed as many
times as required without the need for a license.
• Server-based licensing;
a license is required in order to use the Web Navigator Server.
Licenses are available for simultaneous access to the Web
server by 1, 3, 5, 10, 25, 50, 100 or 150 clients.
• Diagnostics client licensing;
for optimum-cost access by one or a small number of Web
Navigator Clients to numerous Web servers (e.g., for the
purpose of diagnostics). This client license provides
guaranteed access to Web servers at any time. In respect of
function there is no difference compared with regular Web
Navigator Clients and the two can be mixed.
Web Navigator Clients can:
• Access a number of different web servers or
• Access data on a number of higher-level WinCC stations
simultaneously via a remote Web server
■ Function
The Web Configurator (Wizard) makes setting up and configuring a Web Navigator Server very easy. WinCC process
screens to be visualized via the Internet are created as usual
using WinCC Graphics Designer. Under normal circumstances
the project can be worked on locally without modification. The
Web Publishing Wizard optimizes the screens for transmission
and display on the Internet. A standard browser is all that is
required to display WinCC process screens on the Web Client.
The MS Internet Explorer is used depending on the Web
Navigator version used (tip: start the Internet Explorer in fullscreen mode with the start parameter "-k").
The operator on the Web Client is integrated in the central
WinCC user administration and can operate and monitor the
system according to the configured access rights. The Web
Navigator supports all standard security mechanisms that can
be used for applications on the Internet, e.g. routers, firewalls
and proxy servers.
On the server side, only one Web Navigator Diagnostics Server
license or, alternatively, one Standard Web Navigator license is
required.
Alternatively, a number of Web Navigator Servers with the same
WinCC project can be combined to create a "server farm". This
means that it is possible for several hundred Web clients to have
access to the same database. The service ensures that the
clients accessing are distributed evenly across all servers. If a
server fails the Web client is automatically forwarded to the next
available server.
4
In order to use this functionality you will need to install a Web
Load Balancing license on the Web servers involved. Each Load
Balance package contains 2 licenses.
An inexpensive expansion option for Web Load Balancing is
available for redundant WinCC stations on which the Web
Navigator is also installed. For this purpose, you need to install
a Web Load Balancing Step Up license on the web servers
involved. Each Step Up package contains 2 licenses.
Thin Client solutions
The Web Navigator can also run under Windows Server 2003 or
Windows Server 2008 terminal services. A Windows Server 2003
or Windows Server 2008 (or higher) operating system is
required. This makes it possible to connect SIMATIC Thin Clients
as visualization stations to WinCC, for example.
For this purpose, the Windows terminal services must be
installed on the PC on which the Web client is installed. A
Windows Server 2003 or Windows Server 2008 (or higher)
operating system is required. Up to 25 ThinClients can be
connected to one terminal server.
Applications:
• Mobile devices
• Handhelds
• Rugged on-site visualizations
Hybrid configuration
Web Navigator and DataMonitor clients can be mixed in a single
system.
Siemens ST 80 / ST PC · 2013
4/141
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
■ Ordering data
Order No.
WinCC/Web Navigator
4
V7.2; for WinCC V7.2
• 1 client license
• 3 client licenses
• 5 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses
• 100 client licenses
• 150 client licenses
6AV6371-1DH07-2LX0
6AV6371-1DH07-2AX0
6AV6371-1DH07-2MX0
6AV6371-1DH07-2BX0
6AV6371-1DH07-2CX0
6AV6371-1DH07-2DX0
6AV6371-1DH07-2GX0
6AV6371-1DH07-2HX0
WinCC/Web Navigator
Powerpacks V7.2
• From 1 to 3 clients
• From 3 to 5 clients
• From 5 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
• From 50 to 100 clients
• From 100 to 150 clients
6AV6371-1DH07-2LA0
6AV6371-1DH07-2AM0
6AV6371-1DH07-2MB0
6AV6371-1DH07-2BC0
6AV6371-1DH07-2CD0
6AV9681-1DH07-2DG0
6AV9681-1DH07-2GH0
WinCC/Web Navigator
Diagnostics Client
• for WinCC V7.2
6AV6371-1DH07-2EX0
WinCC/Web Navigator
Diagnostics Server
• for WinCC V7.2
6AV6371-1DH07-2FX0
WinCC/Web Navigator upgrade
V6.0 to V7.0; V6.2 to V7.0;
V6.2 to V7.2
• For 3, 10, 25, 50 clients
• Diagnostics server and
diagnostics client
• Load Balancing
WinCC/Web Load Balancing V7.2
• Load Balancing
• Load Balancing Step Up
4/142
Included in corresponding WinCC upgrade
6AV6371-1DH07-2JX0
6AV6371-1DH07-2FJ0
Siemens ST 80 / ST PC · 2013
Order No.
V7.0; for WinCC V7.0,
WinCC V7.0 SP1/SP2/SP3 and
WinCC V7.0 SP1/SP2/SP3 ASIA
• Base Pack (3 client licenses)
• 10 client licenses
• 25 client licenses
• 50 client licenses
6AV6371-1DH07-0AX0
6AV6371-1DH07-0BX0
6AV6371-1DH07-0CX0
6AV6371-1DH07-0DX0
WinCC/Web Navigator
Powerpacks V7.0
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
6AV6371-1DH07-0AB0
6AV6371-1DH07-0BC0
6AV6371-1DH07-0CD0
WinCC/Web Navigator
Diagnostics Client
• for WinCC V7.0
6AV6371-1DH07-0EX0
WinCC/Web Navigator
Diagnostics Server
• for WinCC V7.0
6AV6371-1DH07-0FX0
WinCC/Web Navigator upgrade
V6.0 to V7.0
• For 3 clients
• For 10 clients
• For 25 clients
• For 50 clients
6AV6371-1DH07-0AX4
6AV6371-1DH07-0BX4
6AV6371-1DH07-0CX4
6AV6371-1DH07-0DX4
V6.2 to V7.0
• For 3 clients
• For 10 clients
• For 25 clients
• For 50 clients
6AV6371-1DH07-0AX3
6AV6371-1DH07-0BX3
6AV6371-1DH07-0CX3
6AV6371-1DH07-0DX3
V6.x to V7.0
• For Web Navigator
Diagnostics Client
• For Web Navigator
Diagnostics Server
WinCC/Web Load Balancing V7.0
• Load Balancing
• Load Balancing Step Up
6AV6371-1DH07-0EX4
6AV6371-1DH07-0FX4
6AV6371-1DH07-0JX0
6AV6371-1DH07-0FJ0
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
■ Ordering data
Order No.
WinCC/Web Navigator
System requirements – Web server
V6.2 SP3; for WinCC V6.2 SP3
• Base Pack (3 client licenses)
• 10 client licenses
• 25 client licenses
• 50 client licenses
6AV6371-1DH06-2AX0
6AV6371-1DH06-2BX0
6AV6371-1DH06-2CX0
6AV6371-1DH06-2DX0
V6.2 SP3 ASIA; for WinCC V6.2
SP3 ASIA
• Base Pack (3 client licenses)
• 10 client licenses
• 25 client licenses
• 50 client licenses
6AV6371-1DH06-2AV0
6AV6371-1DH06-2BV0
6AV6371-1DH06-2CV0
6AV6371-1DH06-2DV0
WinCC/Web Navigator
Powerpacks
• V6.2 (for ASIA variants as well)
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
6AV6371-1DH06-2AB0
6AV6371-1DH06-2BC0
6AV6371-1DH06-2CD0
WinCC/Web Navigator
Diagnostics Client
• for WinCC V6.2 SP3
• for WinCC V6.2 SP3 ASIA
6AV6371-1DH06-2EX0
6AV6371-1DH06-2EV0
WinCC/Web Navigator
Diagnostics Server
• for WinCC V6.2 SP3
• for WinCC V6.2 SP3 ASIA
6AV6371-1DH06-2FX0
6AV6371-1DH06-2FV0
WinCC/Web Navigator upgrade
V1.x to V6.2 SP3
• For 3 clients
• For 10 clients
• For 25 clients
• For 50 clients
V6.x to V6.2 SP3
• For 3, 10, 25, 50 clients 1)
• For Web Navigator
Diagnostics Client
• For Web Navigator
Diagnostics Server
V6.x ASIA to V6.2 SP3 ASIA
• For 3, 10, 25, 50 clients 1)
WinCC/Web Load Balancing V6.2
SP3
• Web Load Balancing (2 licenses)
• Web Load Balancing Step Up
(2 licenses)
1)
■ More information
6AV6371-1DH06-2AX4
6AV6371-1DH06-2BX4
6AV6371-1DH06-2CX4
6AV6371-1DH06-2DX4
6AV6371-1DH06-2XX3
6AV6371-1DH06-2EX3
6AV6371-1DH06-2FX3
6AV6371-1DH06-2XV3
6AV6371-1DH06-2JX0
6AV6371-1DH06-2FJ0
Including upgrade for diagnostics client, diagnostics server, Web Load
Balancing and Web Load Balancing Step Up.
For WinCC/Web Navigator V7.2
• Windows 7 SP1 (32- and 64-bit) Business, Enterprise and
Ultimate (max. 3 clients)
• Windows XP Professional Service Pack 3 (max. 3 clients)
• Windows Server 2003 SP2
• Windows Server 2008 SP2 32-bit
• Windows Server 2008 R2 SP1 64-bit
• Internet Explorer V7.0, V8.0 and V9.0
• Microsoft SQL Server 2008 R2 SP1, 32-bit
(included in the WinCC product delivery)
For WinCC/Web Navigator V7.0
• Windows 7 (32-bit) Business, Enterprise and Ultimate
(max. 3 clients)
• Windows XP Professional Service Pack 3 (max. 3 clients)
• Windows Server 2003 SP2 and Windows Server 2003 R2 SP2
• Windows Server 2008 SP2
• Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer
V7.0.
• Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)
• WinCC Basic System V7.0 SP2
For WinCC/Web Navigator V6.2 SP3
• Windows 2000 Professional Service Pack 4 (max. 3 clients)
• Windows XP Professional or Service Pack 3 (max. 3 clients)
• Windows Server 2003 SP2 or Windows Server 2003 R2 SP2
• Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)
• Microsoft SQL Server 2005 SP1 (scope of supply of WinCC)
• WinCC basic system V6.2 SP3
System requirements –Web client
For WinCC/Web Navigator V7.0
• Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer
V7.0
For WinCC/Web Navigator V6.2 SP3
• Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)
WinCC Web Navigator V6.2 SP3 ASIA
(requires SIMATIC WinCC V6.2 SP3 ASIA)
The functions included in this version differ from the standard
version of WinCC/Web Navigator V6.2 SP3 as follows:
• This version does not allow an Asian Web Navigator client to
access a non-Asian server and vice versa.
Siemens ST 80 / ST PC · 2013
4/143
4
© Siemens AG 2013
HMI Software
WinCC add-ons und partner management
WinCC add-ons and partner management
■ Overview
C
WinCis-SW
Bas C, RT
R
C
WinCtion
Op
C
WinCd-on
Ad
C
WinCtion
Op
C
WinCd-on
Ad
4
G_ST80_XX_00175
C
WinCtion
Op
C
WinCd-on
Ad
Premium Add-ons for Connectivity:
• PM OPEN IMPORT system software
for importing WinCC flexible archives into the WinCC system.
• PM OPEN EXPORT system software
for exporting WinCC data to local storage media or storage
media released in the network.
• PM OPEN TCP/IP system software
permits bidirectional exchange of WinCC data (tags,
messages) with one or more computers that communicate
using the TCP/IP protocol.
• Historian CONNECT ALARM system software
permits importing of messages and alarms from WinCC and
WinCC flexible into the SIMATIC IT Historian.
• TOP Server/TOP Server UCON
expands OPC-based the connection capability for WinCC &
WinCC flexible Advanced (PC based runtime)
WinCC Premium Add-ons – Solutions for all sectors and
technologies
The basic system is designed to be independent of any specific
technology or industrial sector, to be modular and flexibly
expandable and to permit not only simple single-user applications in machine construction, but also complex multi-user
solutions or even distributed systems with several servers and
clients in plant engineering. WinCC Premium Add-ons are
supplementary products that have been created by competent
partners working in the specifc sectors and technologies and
represent interesting expansions for WinCC.
WinCC Premium Add-ons are not IA (Siemens Industry
Automation) products, but the products of partners who are
committed to complying with certain quality features and
boundary conditions. The Premium Add-ons are checked, for
example, in the Siemens Test Center for their compatibility with
the basic WinCC system and supported in the first instance by
the central Hotline. As they are important application- and
sector-specific add-on products for SIMATIC WinCC, they are
marketed jointly by Siemens and the respective add-on
suppliers. The WinCC Premium Add-on products can be found
on the Internet (see Further Information) and in the "Online
WinCC Premium Add-on Catalog".
4/144
Siemens ST 80 / ST PC · 2013
Premium Add-on for process management:
• PM CONTROL system software
is a recipe system for user-friendly generation and modification of recipes.
• PM QUALITY system software
is an archive system for the administration of job and batchrelated production and process data.
Premium Add-on for sector products:
• Library SENTRON PAC3200 for SIMATIC WinCC
permits seamless integration of the SENTRON PAC3200 multifunctional measuring instrument in WinCC.
• [email protected] function library
provides function blocks for S7-300/400 as well as faceplates
and icons for WinCC and WinCC flexible from the areas of
process industry, HVAC, pharmaceuticals and energy.
• ACRON for WinCC/PCS 7
is used for long-term archiving and logging of process data for
small to medium-sized plants, specifically in the water supply
and treatment industry.
Premium Add-on for configuration tools:
• DCC TranslationEditor
for translating multilingual projects with in-built security,
convenience and globalization features.
Premium Add-on for diagnostics and maintenance:
• Management System Alarm Control Center
for transmitting fault messages via various communication
paths, such as GSM, LAN, e-mail.
• PM MAINT system software
is a tool for the maintenance of production plants.
• PM ANALYZE system software
for analysis of fault and operating messages, as well as
process values.
© Siemens AG 2013
HMI Software
WinCC add-ons und partner management
WinCC add-ons and partner management
■ Overview (continued)
■ More information
Competent partners
WinCC Competence Center
With SIMATIC WinCC, you not only get excellent products to suit
your requirements, but we will also support you with selecting a
partner for your automation solution. In our global network of
Siemens Automation Solution Providers you will always find
competent partners in your neighborhood. In addition, we
implement and support the Siemens-internal WinCC Competence Centers and the WinCC Professionals external system
integrators on the basis of WinCC customer- and industryspecific and economic solutions.
http://www.siemens.com/winCC/competencecenter
Siemens Solution Partner Automation
http://www.siemens.com/automation/solutionpartner
WinCC Premium Add-on
http://www.siemens.com/winCC/addons
WinCC Competence Centers
Mannheim
Emphasis on process management
• Sector-independent solutions and products in the fields:
Production, environmental protection, maintenance and
diagnostics
• Connectivity tools, system integration, connection to SAP R/3
• Support of FDA validation and WinCC ODK
• Support for advanced users with application of ODK and VBA
• Customer-specific software development for panels,
PCs/IPCs, and servers
• Consulting on web technologies, web servers/thin clients,
DataMonitor
• Customer-specific workshops, e.g. VBS, VBA, and all
WinCC options, e.g. Process Historian
• Information Server and other WinCC topics according to
customer requirements
4
Stuttgart
Emphasis on production technology
• Solutions for maintenance management
• Web-based solutions with WinCC
Nuremberg
Solutions in the Oil & Gas, Metal & Mining, Pulp & Paper sectors
• Network and security
• Microsoft Certified
• Migration from COROS to WinCC
• Customized expansions also for WinCC flexible
• Web solutions
• Customer-specific workshops, e.g. training courses for VBS,
VBA, web technologies à Web Server/Thin Client, DataMonitor
à Webcenter Reports, Excell Workbook, and all WinCC topics
as required by the customer (the latter with lead time)
Further information can be found in the Internet at:
http://www.siemens.com/wincc/competencecenter
Siemens ST 80 / ST PC · 2013
4/145
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Overview
SIMATIC WinCC Open Architecture is a SCADA system for
visualizing and operating processes, production flows,
machines and plants in all industrial sectors.
4
SIMATIC WinCC OA relies throughout on object-oriented structures. Due to this consistent and well-considered use of objectoriented structures, from process pictures to the database, the
engineering costs improve for SIMATIC WinCC OA customers.
Distributed systems enable the connection of up to
2048 autonomous SIMATIC WinCC Open Architecture systems
via one network. Each subsystem can be configured either as
single-user or multi-user system, each of which may be
redundant or non-redundant.
• Current version: SIMATIC WinCC Open Architecture V3.11
Runs on:
- Windows 8 Enterprise (64-bit)
- Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit)
- Windows XP SP2/SP3 (32-bit)
- Windows Server 2008 R2 (64-bit)
- Red Hat Linux 5 (32/64-bit)
- OpenSuse 12.1 (32/64-bit)
- Sun Solaris 10 SPARC (32-bit)
- Sun Solaris 10 x86 (64-bit)
- VMWare ESXi Version 4.0.0 & 5.0.0
Note
Native 64-bit support on 64-bit systems.
■ Benefits
• Efficient engineering and flexible plant expansion
- Object orientation
- Unlimited number of data points
- Mass engineering
- Multilingual with UTF-8 support
4/146
Siemens ST 80 / ST PC · 2013
• Object-oriented data model
- Mapping of setpoint values and measured values for a
physical plant object onto a structured data point
- Data point comprises a tree structure with data point
elements
- The individual process values are mapped onto the data
point elements
- Any number of data points can be instanced from one
defined data point structure (data point type), e.g. 20 pumps
of the same type.
- Data point types can be embedded in other data point types,
which enables more complex plant objects to be generated
(e.g. one pump station comprises 2 pumps).
- Graphical plant symbols can be linked with a data point
type, in which case they only need to be drawn once, but can
be used for all instances of the linked type.
- Savings in engineering outlay.
• Freely scalable
- From a small single-user system up to a networked,
redundant high-end system
- Distributed systems of up to 2048 servers
• Platform-independent
- Available for Windows, Linux and Solaris
• Native 64-bit support
- More system memory is usable, due to native 64-bit support
- This means that larger data quantity structures per server
can be processed
• Maximum fail-safety and availability
- Hot standby redundancy
- Disaster recovery system
- SIL3 certification according to IEC 61508
• Platform for customized solutions
- Quick and easy implementation of new processes
- Swift adaptation of the control and visualization of the plant
to current market requirements
- Company-internal programming and in-house developments enable independence and protection of intellectual
property
- Structure of standardized solutions permits continuous use
- Support of brand-labeling
- Individual brand names for OEM developments
• Openness thanks to comprehensive driver and interface
options:
- Modbus serial, Modbus Plus / RS485, RK512, TLS, Teleperm
M, SSI driver, IEC 60870-5-101, -104, DNP3, SINAUT,
PROFIBUS DP, PROFIBUS S7 + MPI, S7 TCP/IP, Modbus
TCP/IP, Ethernet/IP, OPC DA Client & Server, OPC A&E Client
& Server, OPC UA Client & Server (DA, AC), SNMP, BACnet,
API, Kerberus
• Seamless traceability of system states by means of highperformance archiving:
- Data archiving in value archives (internal database format)
- Data archiving in an Oracle database
• Expandable by means of add-ons and solution frameworks:
- Add-on for quick and easy engineering (Etool, AdvS7, etc.)
- Add-on for increasing the availability (DRS, etc.)
- Add-on for clarity in distributed systems (GIS Viewer, etc.)
- Add-on for efficient maintenance management
(AMS, Scheduler, etc.)
- Add-on for mobile operability
(Web Client, Ultralight Client, etc.)
- Add-on for efficient building automation technology
(BacNet, etc.)
- Add-on for the integration of video management
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Application
The SCADA system SIMATIC WinCC Open Architecture
addresses applications with high demand for customer-specific
adaptations, large and/or complex applications, as well as
projects that demand special system requirements and
functions.
SIMATIC WinCC Open Architecture demonstrates its high
performance in networked and redundant high-end control
systems in particular. Integrated, high-performance communication is guaranteed from the field level to the control station,
from the machine to the company headquarters. In every
situation, high availability, reliable information, fast interaction,
and user friendliness are guaranteed. Applications can also be
changed without interrupting the process. Profitability, efficiency
and safety are therefore always in equilibrium. SIMATIC WinCC
Open Architecture displays its reliability in a wide range of
business-critical applications.
■ Function
SIMATIC WinCC Open Architecture is a very modular SCADA
system. The required functionalities are realized by specific,
functional entities created for various tasks. In SIMATIC WinCC
Open Architecture these units are called "Managers" – they are
also independent processes in software terms.
WinCC OA Manager
Task
Event Manager (EV)
The Event Manager (EV) is the processing center
in WinCC OA. This unit provides a constantly
updated image of all PowerTags in the memory.
Each other functional unit (Manager) that wants to
access the data receives it from the process
image of the Event Manager and does not have to
communicate directly with a controller. Conversely,
a command from an operator station is initially set
only as a value change in the process image of the
Event Manager. The associated driver then forwards it to the corresponding target device
(e.g. PLC) automatically.
The Event Manager is a kind of central data distributor, in effect the communication center for
WinCC OA. Furthermore, this Manager also carries
out the alarm handling and can execute various
arithmetic functions autonomously.
Driver Manager (D)
The lowest level in a WinCC OA System is represented by the process connections, referred to in
WinCC OA as drivers (D). These are special programs that handle the communication with the
control and field level. Since numerous different
forms of communication are possible with the
PLCs or telecontrol nodes, there are different drivers that can be selected. In very simple terms, the
driver is a unit for converting a particular protocol
into the internal communication form of WinCC
OA. The driver reads the current states, measurement or counter values from the field and in the
opposite direction it forwards commands and setpoints to the lower-level controllers (= the term
"control" should be used here and below to represent all possible devices of the basic automation
(PLC, DDC, telecontrol system, etc.)).
With SIMATIC WinCC Open Architecture, ideas can be quickly
and easily converted into new applications. SIMATIC WinCC
Open Architecture is open for independent in-house developments and also enables own product branding.
Thanks to its special system properties, SIMATIC WinCC Open
Architecture meets the highest demands especially in the case
of traffic solutions, building management systems and supply
systems (power, water, oil and gas, etc.).
■ Design
SIMATIC WinCC Open Architecture is available as a single-user
runtime license, multi-user runtime license, Web Client license,
and parameterization and development license. With SIMATIC
WinCC Open Architecture the required license is determined,
among other things, according to the number of inputs and
outputs (I/O).
An "I/O" refers to a data point element (DPE) whose content is
exchanged either by means of drivers (e.g. S7 driver communicates with a PLC), with other software systems. Internal data
point elements, i.e. DPEs without communication to the outside,
are not counted for licensing. The licenses are available either
with an unlimited number of I/Os or with limitations of 500 to
250 000 I/Os.
The multi-user runtime license allows working simultaneously
from different PCs, with the licensing taking place via the server.
The active clients are then counted. The web client and the ultralight client enable the visualization and operation of process
pictures over an exclusively HTTP connection between the
server and the respective web client. The parameterization and
development licenses extend a runtime license with the option of
configuration and parameterization. They each require a server
license.
Data Manager (DB)
The Data Manager (DB) represents the link to
database. On one hand, it involves the parameterization data of an application that is to be stored in
such a database. On the other hand, it involves the
historical recording of changes in values or
alarms. If a user wishes to query historical data at
a later date, then the Data Manager completes this
request and not the database itself.
Siemens ST 80 / ST PC · 2013
4/147
4
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Function (continued)
WinCC OA Manager
Task
Control Manager
(CTRL)
WinCC OA has numerous options for implementing your own algorithms and processing. The two
most important are the internal language control
(CTRL) and the general application programming
interface (API).
Control is an extremely powerful scripting language. The processing is interpretative, so that no
compilation is required. The syntax is almost identical with ANSI-C, with some modifications for simplification. This is a fully developed, procedural
high-level language with multi-threading (= quasiparallel processing of individual programs; the
system itself carries out the processing check).
The language offers a comprehensive function
library for tasks of the control and visualization
technology. Control can be used as a stand-alone
process (Control Manager), for animation and user
interface design or for standardized, data objectoriented processing functions.
The API (WinCC OA API) represents the most powerful form of functional expansion. It is configured
as a C++ class library and allows the software
developer to implement individual functions as an
independent, additional manager (forecast system, simulation, tools, proprietary databases,
etc. ).
The interface to the user is created by the User
Interface Manager (UI). This comprises a graphics
editor (GEDI), a database editor (PARA) or the
general user interface of the application (Vision
module). The User Interface serves to display values, issue commands or track alarms in the alarm
list. Trends and reports are also usually part of the
UI. From a programming viewpoint, the user interaction in WinCC OA is completely isolated from the
background processing – this is merely a view of
the data of the current process image or the history.
4
UI
UI
UI
Userinterface
Editorr
Userinterface
Runtimee
Userinterface
Runtimee
CTRL
API
Control
manager
API
manager
DB
EV
CON
Database
manager
Event
manager
Connection
to other
systems
D
D
D
Driver
Driver
Driver
Visualization, Operation
UI
GEDI
PARA
= Runtime
= Graphical Editor
= Database Editor
Processing, Control
Control = Script language
Manager = Application
API
Programming
Interface
Process Image, History
Event manager = Communication
and Alarming
Data manager, = History
RDB
Process Interface
Driver: PLC, Field busses, DDC,
Telemetry/RTU, Special drivers
G_ST80_XX_00463
User Interface
Manager (UI)
A WinCC OA System consists of function-specific units, the managers
4/148
Siemens ST 80 / ST PC · 2013
For special tasks such as redundancy, management for
distributed systems, web server, reporting, simulation, COM
etc., further managers are available.
The powerful configuration functions contribute to a reduction of
engineering and training overheads and lead to increased flexibility and operational reliability.
Special functions
Task
Access to external
databases
The database interfaces offer the possibility of
access to external databases.
Under Windows, the link is established via the
ADO Standard. ADO (ActiveX Data Objects) is an
interface developed by Microsoft for vendor-independent access to data sources of all types, primarily databases. The data source for ADO is an
OLE DB Provider, although ODBC-compatible
databases can also be addressed via an internal
wrapper.
In Linux, the Qt library is used as an interface to
relational databases. Access in this case is either
direct via the native DB-API or via ODBC.
Application Programming Interface (API)
The API offers a series of functions that enable
WinCC OA to be extended with special managers.
A manager means a program that communicates
with the system by via a protocol defined by
WinCC OA.
COM (Component
Object Model)
This is a specification for the development of modular software components that can be used by
each COM-compatible application.
COM components can easily be integrated into
such applications and can even be removed from
an application during runtime. COM components
can be programmed in a host of different languages, even though C++ is usually used for this
purpose. The specifications OLE, ActiveX and
DirectX are based on the COM technology.
Control expansion
Expansion that allows C++ functions to be added
to the programming language.
Panel topology/
summation signal
Generation of panel hierarchies/topologies in
existing or new projects and automatic creation of
summation signals of the alarm data points that
are located in the panels of the topology.
Redundancy
(see figure below)
The failure safety in a redundant system is implemented by means of hot standby.
Hot standby is a hardware-independent solution
for high availability. This is a safety concept that
consists of two interconnected server systems.
Both servers are constantly in operation and are
subject to the same functional loading (but only
one server is ever active; the second compares
the data with the primary unit at runtime).
On the failure of one unit, an "on-the-fly
changeover" takes place and the previously
passive server assumes the leading role. This
guarantees access to data or functions at all
times.
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Function (continued)
Special functions
Task
Special functions
Task
SMS
Allows the sending and receiving of text messages
with WinCC OA.
Drag and Draw
Encryption of panels
and CTRL scripts/
libraries
Allows your panels or scripts to be encrypted,
thereby protecting your knowledge and work.
Several representative graphical objects can be
defined and configured for each plant object in the
data model (data point type). These are pre-configured and need only be moved to the panel via
drag-and-drop when the plant pictures are drawn.
This saves valuable time during engineering.
Script Wizard
Easy-to-use tool that simplifies the creation of animated, graphical plant symbols, which saves time
during engineering.
Distributed systems
(see the diagram
below)
Simple Symbols
Basic package of plant symbols that have been
created using the script wizard. These can be
adapted quickly and easily to the specific requirements of the customer.
Easy Faceplates
Simple parameter assignment of predefined popup windows that display details of the associated
plant symbol. Without any additional drawing outlay, several standard functions per object can be
activated for the detail view (alarm display, trend
display, measured value table, setpoint value
table, address table, notes).
Permits the coupling of two or more autonomous
WinCC OA systems via a network. Each subsystem of a distributed system can be configured
either as a single-user or multi-user system, each
of which may be redundant or non-redundant.
A sub-system in this context means a server on
which an Event Manager is running, whereby in
case of redundancy both redundantly operating
servers are considered as one system.
Operational station 1
UI
UI
Userinterface
Runtime
Userinterface
Runtime
Server 2
CTRL
CTRL
Control
manager
Control
manager
EV
DB
Event
manager
Database
manager
REDU
REDU
Redundancy
manager
Redundancy
manager
Event
manager
D
D
Driver
Driver
Process connection
The diagram shows a detailed representation of the two
computers Server 1 and Server 2. Server 1 is in the management
mode (active) and Server 2 is in hot standby mode (passive).
In the case of redundant operation, the UIs of both operator
stations are connected to both Event Managers, however only
the data of the active system is displayed on both UIs.
Process connection
DB
Database
manager
G_ST80_XX_00479
Message direction
Server 1
ACTIVE
4
Operational station 2
HOT-STANDBY
The Event Manager of the passive system is restricted exclusively to communication with the Event Manager of the active
system for comparison of the process data (it sends no data to
the connected UIs or it discards messages from the drivers – this
can be seen in the figure with the switches on the UIs or on the
passive Event Manager).
Siemens ST 80 / ST PC · 2013
4/149
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Integration
Integration in automation solutions
SIMATIC WinCC Open Architecture is an open SCADA system
with comprehensive drivers and flexible options for connection
to other external systems.
Depending on the communications protocol and the bus
physics used, specific drivers are used in each case:
• Serial protocols: RK512, 3964R, etc.
• Ethernet: Industrial Ethernet (S7), Modbus TCP
(OpenModbus), Ethernet IP (AB), etc.
• Telecontrol systems: SINAUT, SSI (Ethernet),
IEC 60870-5-101, IEC 60870-5-104, etc.
• Vendor-independent interfaces: OPC UA, etc.
In SIMATIC WinCC Open Architecture, several drivers can be
operated in parallel. These can be of the same type or also of
different types. It is possible in a SIMATIC WinCC Open Architecture system, for example, to establish connections via the
S7 protocol to a SIMATIC controller, via IEC 60870-5-104 to a
telecontrol system, and via OPC DA to any OPC server at the
same time.
Coupling overview
4
Protocol
Description
Protocol
Description
SIMATIC S7
via TCP/IP and MPI
SSI
OPC Client
(Data Access)
• Compatibility with the specifications DA 1.0
and 2.05a
• Connection to inproc, local or remote server
• Connection with up to 20 servers at the same
time
• Monitoring of the connection to the server
and automatic reconnection if the connection
is interrupted.
• Address browsing if supported by the server.
• Benefits of the CALL-R functionality for CALL-R
servers (simplified parameter assignment)
Is used for the interfacing of SAT remote control
systems. The data is exchanged via the LAN
(Ethernet, IEEE 802.3); the frame formats used
are the SSI formats defined by SAT. The SK 1703
telecontrol components with a suitable communication card (KE/ET) are supported.
IEC 60870-5-101, -104
IEC drivers are standardized telecontrol drivers
that can process proprietary frames. IEC stands
for International Electrotechnical Commission,
the international standardization committee for
electrical engineering.
• IEC 60870-5-104 for data exchange via TCP/IP
• IEC 60870-5-101 for serial connection
DNP3
The DNP3 (Distributed Network Protocol 3)
driver is an open, rugged and modern protocol
which exhibits characteristics and strengths similar to the IEC driver. The transfer of any number
of frames with different data types takes place
between the WinCC OA System (Master) and the
remote stations (Slave).
SINAUT
SINAUT (SIemens Network AUTomation) is a
communication protocol for automated monitoring and control of remote process stations on the
basis of SIMATIC S7. Communication takes
place via TCP/IP.
SNMP Manager & Agent
SNMP (Simple Network Management Protocol)
is a protocol for monitoring network elements
(servers, workstations, routers, switches, hubs,
etc.) and their functions.
• SNMP Manager supports SNMP V1, V2, and V3
• SNMP Agent supports SNMP V1 and V2
BACnet over IP – driver
BACnet (Building Automation and Control Networks) is a standardized protocol for building
automation and has been set by the ASHRAE
(American Society of Heating, Refrigerating and
Air-conditioning Engineers) as a guideline to provide a uniform and cross-company standard for
data communication within and between building automation systems.
OPC Server
(Data Access)
OPC Alarms & Events
• Corresponds to Data Access 2.05a specification (reading/writing of online values).
• Is to be started as a manager just like other
drivers.
• The provided DPEs (server -> client) can be
easily and quickly defined via data point
groups.
• DPEs can be declared as readable (read-only
access is permitted; Group OPCRead) or as
writable items (Group OPCWrite).
• Clients can browse the WinCC OA OPC Server
hierarchically.
OPC Alarms & Events (abbreviated to OPC A&E)
is, in addition to Data Access, a further standard
for performing central alarm management on a
cross-vendor basis. OPC A&E is used to ensure
the link to other control systems and the display
of alarms/events in a hierarchical system.
OPC UA
(Unified Architecture)
• The OPC UA client supports the OPC UA standards Data Access and Alarms & Conditions.
• The OPC UA Server supports the OPC UA standards Data Access and Alarms & Conditions.
Modbus TCP
Modbus/TCP is based on the serial Modbus
protocol, which was adapted for TCP/IP.
The Modbus/TCP driver can be used
simultaneously for Modbus/TCP or UNICOS.
Serial: RK512/3964R
Is used for interfacing a PLC via the 3964R/
RK512 protocol
Cerberus
Cerberus is a fire, intrusion and gas alarm system. The Cerberus driver guarantees communication to and from the central fire alarm systems
and building security facilities in the event a fire,
gas or intruder alarm.
The BACnet Standard 2004 is supported in
accordance with the PIC list (see product documentation)
Dynamic Logic – driver
The Dynamic Logic driver communicates
with different Dynamic Logic devices via the
"FSK outstation protocol".
Applicom General
Interface
Applicom is, among other things, a manufacturer
of I/O cards and software tools, with a wide
range of applications in automation engineering.
The Applicom products are compatible with
many common fieldbus systems and communications components.
Further drivers on request or via C++ API
4/150
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Technical specifications
Type
SIMATIC WinCC Open Architecture V3.11
Type
Operating system
• Windows 8 Enterprise (64-bit)
Functionality/quantity
structure
• Windows 7 Ultimate/Enterprise/Professional
SP1 (32/64-bit)
SIMATIC WinCC Open Architecture
Number of messages
150,000 2)
Message text
(number of characters)
System-limited 1)
• Windows Server 2008 R2 (64-bit)
• Red Hat Linux 5 (32/64-bit)
Message archive
System-limited 1)
Process values per message
1 process value + up to 32 alarm associated
values per message
Constant load of messages,
max.
500/s 2)
Message burst, max.
15,000/10 s every 5 min 2)
• Windows XP SP2/SP3 (32-bit)
• OpenSuse 12.1 (32/64-bit)
• Sun Solaris 10 SPARC (32-bit)
• Sun Solaris 10 x86 (64-bit)
• VMWare ESXi Version 4.0.0 & 5.0.0
Note:
Native 64-bit support on 64-bit systems
PC hardware requirements 1)
Archives
Archive data points
Max. 250,000 per server 2)
Archive types
< 20 parallel logs, different retention period for
each log
Processor type
Intel Pentium or equivalent
Minimum
Intel Pentium IV 1.6 GHz (or better)2)3)
Recommended
• Client: Intel Pentium IV/Core2/i3, 2 GHz2)3)
• Server: Intel Core i3 CPU Dual, 3 GHz2)
• Server large system4): Intel(R) Core(TM) i5/i7
CPU Dual / Quad, 3 GHz2)3)
Data storage format
Oracle or file system
Measured values per second, max.
Server/single-user station: 7,000/s 2) 3)
Minimum
2 GB 2)
Archives
System-limited 1)
Recommended
• Client: 2 GB 2)3)
• Server: 8 GB 2)3)
• Server large system: 16 GB 2)
Type
SIMATIC WinCC Open Architecture
Table size
System-limited by ORACLE database
User archive
RAM
Hard disk
(available memory for
installation)
Minimum
HD with 800 MB available 2)
Recommended
Server large system with local logging:
SCSI LVD Controller, WIDE SCSI / LVD HDD
or comparable storage system with at least
500 MB of available space 2)
Number of screens
System-limited 1)
Number of objects per
screen
System-limited 1)
Number of controllable
fields per screen
System-limited 1)
PowerTags
< 750,000 per server 2)
User administration
Screen and graphics card
(TrueColor)
User accounts
< 4096
Minimum
1024 x 768 2)
Configuration languages
2 (De, En)
Recommended
1280 x 1024 2)
Runtime languages
40 (of which 8 Asian)
Mouse and keyboard
Mouse, keyboard
Multi-user system
DVD drive
for software installation
Server
< 2048 2) 4)
Local power user rights
• for installation
• for operation
Number of clients
< 244 per server 2) 5)
1)
4
Graphics system
For actual use in plants, the hardware requirements are largely dependent
on the project size and the dynamic response of the process variables.
Whenever possible, use rugged, high-quality hardware with corresponding
functionalities such as redundant power supply units or RAID hard disks.
WinCC OA supports dual and multi-processor mode and benefits significantly from the fact that each WinCC OA Manager can be assigned to one
processor core as a system process. At the same time, however, it is
important that the individual cores offer the highest possible performance
(high clocking), since load-critical core processes such as the event
manager run on exactly one core (for this reason, multi-core machines with
low-clocked cores are unsuitable for WinCC OA). As for RAM, CPU and
HDD, the usual rule applies: more is better
2)
System requirements generally only refer to WinCC OA Version 3.11 under
the supported versions of the Windows and Linux operating systems
3)
A precondition for the minimum requirement is that the operating system
used does not have any greater requirements itself
4)
With a large system it is essential that the system permits not only the
highest data point numbers but also a high dynamic response
1)
Dependent on the available storage space
2)
Dependent on the system configuration and the system load (due to the
event-oriented architecture, the system load is essentially determined by
the change rates of the values to be processed)
3)
By means of high-performance hardware configuration (one archiving
cluster and approx. 120 distributed systems that archive parallel values in
the cluster): 200,000 archived value changes per second
4)
Physical limit: <2048, in practice systems have already been implemented
with up to 550 distributed systems
5)
Physical limit: < 244 clients per server, recommended: max. 100 clients per
server
WinCC OA is ideally suited for use in very large distributed
systems. The optimum design of such systems demands corresponding system knowledge of WinCC OA. Due to the eventoriented processing, individual design parameters can be
increased or reduced as necessary in actual applications.
Siemens ST 80 / ST PC · 2013
4/151
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Ordering data
Order No.
SIMATIC WinCC
Open Architecture
system software V3.11
WinCC OA core components
WinCC OA Server
Language/script versions: De, En;
with license for:
WinCC OA single-user station
500 I/O V3.11
License for single-user station with
up to 500 I/Os of any type (bit, integer), alerting, extended trend, historical recording, not expandable to
more than one operator station, not
expandable by means of add-ons,
including S7 driver, OPC client,
OPC server, and OPC UA client.
4
WinCC OA Server I/O V3.11
License for server (without operator
station licenses), alerting, extended
trend, historical recording,
including S7 driver, OPC client,
OPC server, and OPC UA client.
• WinCC OA Server 1,000 I/O V3.11
with a max. of 1,000 I/Os of any
type
• WinCC OA Server 3,000 I/O V3.11
with a maximum of 3,000 I/Os of
any type
• WinCC OA Server 5,000 I/O V3.11
with a max. of 5,000 I/Os of any
type
• WinCC OA Server 10,000 I/O
V3.11
with a max. of 10,000 I/Os of any
type
• WinCC OA Server 15,000 I/O
V3.11
with a max. of 15,000 I/Os of any
type
• WinCC OA Server 25,000 I/O
V3.11
with a max. of 25,000 I/Os of any
type
• WinCC OA Server 50,000 I/O
V3.11
with a max. of 50,000 I/Os of any
type
• WinCC OA Server 75,000 I/O
V3.11
with a max. of 75,000 I/Os of any
type
• WinCC OA Server 100,000 I/O
V3.11
with a max. of 100,000 I/Os of any
type
• WinCC OA Server 150,000 I/O
V3.11
with a max. of 150,000 I/Os of any
type
• WinCC OA Server 200,000 I/O
V3.11
with a maximum of 200,000 I/Os of
any type
• WinCC OA Server 250,000 I/O
V3.11
with a maximum of 250,000 I/Os of
any type
4/152
Order No.
WinCC OA Server unlimited V3.11
6AV6351-1HA31-1AA0
6AV6351-1HB31-1AA0
6AV6351-1HC31-1AA0
6AV6351-1HD31-1AA0
License for server and one singleuser station (expandable to several
operator stations by means of clients) with unlimited number of I/O,
alerting, extended trend, historical
recording, including S7 driver,
OPC client, OPC server, and
OPC UA client.
WinCC OA Dongle V3.11
Hardware dongle on the USB port
for operation with a hardware-independent license attached to the
dongle, which can also extend the
hardware-linked license of the operator station or server on a temporary
basis.
6AV6351-1AH31-1AA0
WinCC OA on data medium
WinCC OA Software DVD – current
version on disk
6AV6351-1AX31-1AA0
WinCC OA Client floating
Language/script versions: De, En;
with license for:
WinCC OA Client V3.11
Additional operator station license
with all server operator station
functionalities.
The client license can be installed
on more than one PC – only the
number of simultaneously active
clients is counted.
6AV6351-1HE31-1AA0
WinCC OA Web User Interface
Language versions: De, En; with
license for:
6AV6351-1HF31-1AA0
WinCC OA Web Client V3.11
Web client license for WinCC OA
Server. Only the number of simultaneously active web clients is
counted.
6AV6351-1HG31-1AA0
6AV6351-1HH31-1AA0
6AV6351-1HJ31-1AA0
6AV6351-1HK31-1AA0
6AV6351-1HL31-1AA0
6AV6351-1HM31-1AA0
6AV6351-1HN31-1AA0
Siemens ST 80 / ST PC · 2013
6AV6351-1HP31-1AA0
6AV6351-1CP31-1AA0
6AV6351-1DP31-1AA0
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Ordering data
Order No.
WinCC OA Ultralight Client
WinCC OA Ultralight PC Client
Licenses for one or several ultralight
clients running on a laptop or PC.
Only the number of simultaneously
active ultralight clients is counted.
Please note restrictions of the ultralight client according to the online
help.
• WinCC OA 1 Ultralight PC Client
License for one ultralight client
• WinCC OA 3 Ultralight PC Clients
License for 3 ultralight clients
• WinCC OA 10 Ultralight
PC Clients
License for 10 ultralight clients
WinCC OA Ultralight Mobile Client
Licenses for one or several ultralight
clients running on a smartphone or
tablet PC. Only the number of simultaneously active ultralight clients is
counted. Please note restrictions of
the ultralight client according to the
online help.
• WinCC OA 1 Ultralight Mobile
Client
License for one ultralight client
• WinCC OA 3 Ultralight Mobile
Clients
License for 3 ultralight clients
• WinCC OA 10 Ultralight Mobile
Clients
License for 10 ultralight clients
6AV6351-1JA31-1AA0
6AV6351-1JB31-1AA0
6AV6351-1JC31-1AA0
6AV6351-1JG31-1AA0
Order No.
WinCC OA API interface
gen. V3.11
Application programming interface
for the integration of customer-specific managers or drivers. One
license is required for each development workstation. We strongly recommend the participation in a
Certified WinCC OA Developer
Workshop when ordering this
product for the first time.
6AV6351-1EK31-1AA0
WinCC OA Custom Driver V3.11
Extends a WinCC OA server license
with the option of communication
with a customer-specific driver. One
license is required for each customer-specific driver.
6AV6351-1EL31-1AA0
WinCC OA Custom Manager V3.11
Extends a WinCC OA server license
with the option of communicating
with a customer-specific manager.
One license is required for each
customer-specific manager
6AV6351-1EM31-1AA0
WinCC OA redundancy
6AV6351-1JG31-1AA0
6AV6351-1JH31-1AA0
WinCC OA Redundancy V3.11
Extends a WinCC OA Server with
the option of bumpless switchover
to a hot standby partner.
6AV6351-1FP31-1AA0
4
WinCC OA distributed systems
6AV6351-1JJ31-1AA0
WinCC OA parameter assignment
and development license
WinCC OA Para for single-user
station V3.11
Parameterization and development
license for single-user station,
graphic editor with symbol catalog
and ActiveX Controls, user-friendly
script development language, alerting, extended trend, historical
recording. Requires a corresponding single-user station license.
6AV6351-1EA31-1AA0
WinCC OA Para V3.11
Parameterization and development
license for server, graphic editor
with symbol catalog and ActiveX
Controls, user-friendly script development language, alerting,
extended trend, historical recording.
Requires corresponding server
license.
6AV6351-1EP31-1AA0
WinCC OA ETool V3.11
License for the use of the integrated
WinCC OA ETool engineering environment, including the object library
S7-BaseLib.
Intellectual property right owner:
Siemens AG.
6AV6351-1EJ31-1AA0
WinCC OA distributed systems
V3.11
Extends a WinCC OA Server to
include the Multiserver option.
6AV6351-1GP31-1AA0
WinCC OA Disaster Recovery
System
WinCC OA Disaster Recovery
Center V3.11
Allows the configuration of a remote
backup control center. A disaster
recovery center comprises two distributed systems. Each system can
be redundant or non-redundant.
Requires Oracle databases and
RDB. Refer to the online help for
example configurations. Each
server in the Disaster Recovery
System requires one WinCC OA
Disaster Recovery Center option.
6AV6352-1AA31-1AA0
Siemens ST 80 / ST PC · 2013
4/153
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
■ Ordering data
Order No.
SIMATIC WinCC Open Architecture
V3.11 communication
4
Order No.
WinCC OA SINAUT 25 devices
SINAUT driver for connecting
up to 25 controllers
6AV6352-1BR31-1AA0
WinCC OA SINAUT 50 devices
SINAUT driver for connecting
up to 50 controllers
6AV6352-1BS31-1AA0
WinCC OA TLS driver
Driver in accordance with TLS regulations in connection with Siemens
Commbox (see separate data sheet).
6AV6352-1BA31-1AA0
WinCC OA Teleperm M
Driver for Teleperm M Bus C275
(requires an Acotex Comm Box)
6AV6352-1BB31-1AA0
WinCC OA SINAUT 250 devices
SINAUT driver for connecting
up to 250 controllers
6AV6352-1BT31-1AA0
WinCC OA S7 TCP/IP driver
TCP/IP for Siemens Industrial Ethernet
6AV6352-1BC31-1AA0
WinCC OA SINAUT unlimited
SINAUT driver – unlimited license
6AV6352-1BU31-1AA0
WinCC OA Modbus TCP/IP driver
TCP/IP for Schneider Modbus
6AV6352-1BD31-1AA0
6AV6352-1CA31-1AA0
WinCC OA Modbus serial
Serial driver for Schneider Modbus
6AV6352-1BE31-1AA0
WinCC OA RK512
Driver for connection
via 3964R / RK512 protocol
6AV6352-1CB31-1AA0
WinCC OA SSI driver
Driver for SAT telecontrol components
6AV6352-1BF31-1AA0
WinCC OA PROFIBUS DP
Driver PROFIBUS DP,
an Applicom card is required
6AV6352-1CC31-1AA0
WinCC OA SNMP
Driver SNMP – network monitoring
(V2&V3)
6AV6352-1BG31-1AA0
WinCC OA PROFIBUS S7
Driver PROFIBUS S7 + MPI,
an Applicom card is required
6AV6352-1CE31-1AA0
WinCC OA IEC 104
Driver IEC 60870-5-104
6AV6352-1BH31-1AA0
WinCC OA Omron FINS TCP-IP
Driver Omron FINSTCP-IP,
an Applicom card is required
6AV6352-1BJ31-1AA0
WinCC OA GE Fanuc SRTP
Driver GE Fanuc SRTP,
an Applicom card is required
6AV6352-1CF31-1AA0
WinCC OA IEC 101
Driver IEC 60870-5-101
WinCC OA DNP3 10 devices
Driver DNP3 for connecting
up to 10 DNP3 devices
6AV6352-1BK31-1AA0
WinCC OA Allen Bradley Ethernet/IP
Driver Allen Bradley Ethernet/IP,
an Applicom card is required.
6AV6352-1CG31-1AA0
WinCC OA DNP3 25 devices
Driver DNP3 for connecting
up to 25 DNP3 devices
6AV6352-1BL31-1AA0
6AV6352-1CH31-1AA0
WinCC OA DNP3 50 devices
Driver DNP3 for connecting
up to 50 DNP3 devices
6AV6352-1BM31-1AA0
WinCC OA Cerberus
Driver for connection with the Siemens
DMS7000 / Cerberus fire alarm system. Communication is implemented
via the C-Bus (Cer-Ban) using the
serial interface RS 232 (MK 7022).
6AV6352-1BN31-1AA0
WinCC OA OPC UA Server
Driver for OPC UA DA and
OPC UA AC Server
6AV6352-1CJ31-1AA0
WinCC OA DNP3 250 devices
Driver DNP3 for connecting
up to 250 DNP3 devices
WinCC OA DNP3 unlimited
Driver DNP3 – unlimited license
6AV6352-1BP31-1AA0
WinCC OA SINAUT 10 devices
SINAUT driver for connecting
up to 10 controllers
6AV6352-1BQ31-1AA0
■ More information
Further information can be found in the Internet at:
http://www.siemens.com/wincc-open-architecture
4/154
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
■ Overview
SIMATIC WinCC Open Architecture is a SCADA system for
visualizing and operating processes, production flows,
machines and plants in all industrial sectors.
SIMATIC WinCC OA is built consistently on object-oriented
structures. The rigorous and well-considered use of objectoriented structures, from process images to the database, help
to improve engineering costs for SIMATIC WinCC OA customers.
Distributed systems enable the connection of up to 2048 autonomous SIMATIC WinCC Open Architecture systems via one
network. Each subsystem can be configured either as singleuser or multi-user system, each of which may be redundant or
non-redundant.
• Current version: SIMATIC WinCC Open Architecture V3.11
Runs on:
- Windows 8 Enterprise (64-bit)
- Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit)
- Windows XP SP2/SP3 (32-bit)
- Windows Server 2008 R2 (64-bit)
- Red Hat Linux 5 (32/64-bit)
- OpenSuse 12.1 (32/64-bit)
- Sun Solaris 10 SPARC (32-bit)
- Sun Solaris 10 x86 (64-bit)
- VMWare ESXi Version 4.0.0 & 5.0.0
Note:
Native 64-bit support on 64-bit systems.
■ Function
SIMATIC WinCC Open Architecture add-ons
The universal WinCC Open Architecture basic software is the
basis for modular expansions. These functional expansions are
available in the form of WinCC Open Architecture add-ons.
Field devices
or other connected systems
4
MODBUS (TCP)
WinCC OA
Server (multi-user system)
OPC UA (TCP)
WinCC OA
Server
(stand alone
system)
Operational station
System 3
Operational station
System 2
WinCC OA System communication TCP
System 1
WinCC OA
Server
(redundant)
Operational station
Operational station
Operational station
G_ST80_XX_00480
S7 Industrial Ethernet (TCP)
Distributed systems with WinCC OA
Siemens ST 80 / ST PC · 2013
4/155
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
■ Function (continued)
4
Add-ons
Task
Add-ons
Task
ETool
The engineering tool ETool offers significant
benefits in engineering in the case of combined
WinCC OA and SIMATIC STEP7/PCS7 projects. It
provides a user-friendly engineering environment
that permits easy, integrated and fast configuration
on the basis of the WinCC OA mass parameterization.
Video
(see figure below)
Enables the integration of a video management
system in WinCC OA. Through the combination of
SCADA and video monitoring in one system, the
costs for separate video interfaces and the additional expense of maintenance and operation can
be saved, and the period of training for operating
personnel can also be reduced.
BACnet
BACnet provides an integrated BACnet-compliant
online/offline engineering solution for building
automation technology, including object library.
Designed for heating, ventilation and air-conditioning, lighting control and safety systems.
HTTP server
For displaying WinCC OA data via Intranet and
Web.
Authentication
via Kerberos
A WinCC OA system can be exposed to a variety
of attacks. An unauthorized WinCC OA System
could set up a connection to the distribution manager or hackers could try to manipulate WinCC OA
messages. Secure authentication has been developed to prevent such attacks. The authentication
based on Kerberos enables each WinCC OA component to verify the identity of another component.
WinCC OA servers can verify the identity of the clients and clients can verify the identity of the servers. In addition, Kerberos ensures that messages
are not modified during their transmission (capture-replay attacks are prevented). Furthermore,
it is also possible to send messages in encrypted
form.
AMS (Advanced
Maintenance Suite)
For the effective planning, administration, implementation and monitoring of maintenance work
and faults. The processes are evaluated by means
of statistics and reports are communicated.
Web client
From a technical standpoint, the WinCC OA Web
Client is a plug-in that is downloaded via the web
browser (which is used on the client computer)
and a WinCC OA UI Manager is then displayed
embedded in the HTML page. No WinCC OA
installation on the client computer is required,
except for the required web client plug-ins.
Ultralight client
A "thin client" that supports access to the plant via
a mobile device (such as a cell phone or tablet) in
addition to a PC workstation. Access is possible
via a standard Web browser using native Web
technologies (Javascript, SVG) without the need
for any additional installations. It provides a user
interface even at those locations with Internet connections offering very low bandwidth, as only the
most essential data is transferred.
Disaster Recovery
System
(see figure below)
This system expands the simple redundancy to
include a second redundant system, to which the
system can switch over in the event of a fault
(e.g. fire or explosion in the building of the primary
system). By means of this additional local redundancy, the highest level of system stability is
obtained.
S7 AdvancedLib
object library
The S7 AdvancedLib (AdvS7) is an industry-independent object library that permits the use and
visualization of objects from the process control
system (e.g.: drives, valves, regulators, motors,
etc.) in a project with WinCC OA and S7. In addition to the WinCC OA and AdvS7 license, the use
of S7 AdvancedLib requires the use of the relevant
library on the SIMATIC side.
Maintenance package
Includes the following functions: Operating hours
counter, operating cycle counter and maintenance
log.
Scheduler
Permits the creation, parameterization and management of time programs that allow the time and
event-driven triggering of specific actions.
Recipes
WinCC OA recipes allow setpoints or commands
for certain data point elements to be sent simultaneously. Based on "recipe types", which define the
quantity of the assigned data point elements, recipes are created that send their values to the data
point elements upon activation.
With the help of this viewer, standardized cards of
a geo-information system (GIS) can be fully integrated in WinCC OA. Furthermore, it is possible to
display all WinCC OA objects in the cards.
GIS Viewer
Powerful report generator directly in Microsoft
Excel. Templates can be created easily and
directly in Excel. If a report has to be created over
a defined period of time, the system accesses the
template and automatically completes it with data
from the WinCC OA process database. Reports
can also be created, printed and saved on a timecontrolled basis, without any need for user access.
The Excel Report fully supports compression
structures (AC - archive compression) of
WinCC OA.
Excel report
Communication
Center
4/156
Stands for modern alarm management/remote
alerting and communication using the latest standards and various media. The Communication
Center creates synergies by using the various
interfaces for remote alerting via the control
system.
Text message and email media are covered with
the Communication Center.
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
■ Function (continued)
Video workstation
Monitor 1
Operator keyboard
mouse
joystick
Video monitor 1
Video monitor 2
(optional)
Control monitor
(optional)
Encoder
Control commands
TCP/IP
connection
Decoder
Cameras or
crossbars
Network
video recorder
WinCC OA
Server
Control of monitor wall via POSA protocol
Monitor wall
(monitors 2 ... n)
G_ST80_XX_00481
4
Network topology Video
Primary Server System (PSS)
Secondary Server System (SSS)
Database in
Oracle Cluster
WinCC OA
active
Server (A)
WinCC OA
Hot-Standby
System
WinCC OA
passive
Server (B)
Operating Interface
with one or two
interfaces
WinCC OA
active
Server (C)
WinCC OA
Hot-Standby
System
WinCC OA
passive
Server (D)
Field device or other
connected systems like
for example OPC UA
G_ST80_XX_00482
Database in
Oracle Cluster
Disaster Recovery System architecture with WinCC OA
Siemens ST 80 / ST PC · 2013
4/157
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
■ Ordering data
Order No.
SIMATIC WinCC
Open Architecture add-ons
4
Order No.
Solution Frameworks
WinCC OA PMS
Application framework for the implementation of production management
systems. The framework offers
functions for recording and evaluating
production and batch-related quality
data. This item is not available as a
product but only in combination with
consulting and additional testing
overhead.
6AV6352-1EA31-1AA0
WinCC OA topology package
The topology package is an application framework enabling the topological coloring of network views.
A qualitative statement is made
regarding which parts of a network are
directly connected to which infeed
units in a connection established by
switching elements. Only available in
combination with consulting and additional testing overhead.
6AV6352-1EB31-1AA0
WinCC OA ACAS
WinCC OA Advanced Command
Authority Suite framework for managing and visualizing authority settings.
The license includes the management
panel and panel expansions for alarm,
horn and acknowledgement functions. This item is not available as a
product but only in combination with
consulting and additional testing overhead.
6AV6352-1EC31-1AA0
WinCC OA BACnet driver +
diagnostics
Extends a WinCC OA Server to include
a license for using the WinCC OA
BACnet online engineering environment consisting of WinCC OA BACnet
driver, WinCC OA BACnet object
library including faceplates, and
WinCC OA BACnet browser
(max. 5,000 objects per server).
6AV6352-1DA31-1AA0
WinCC OA BACnet Engineering
Extends a WinCC OA Server to include
a license for using the WinCC OA
BACnet engineering environment consisting of WinCC OA BACnet browser,
WinCC OA EDE-Tool + EDE file interface (requires the WinCC OA engineering license) (max. 5,000 objects
per server).
6AV6352-1DB31-1AA0
WinCC OA GIS
GIS viewer for displaying ESRI Shapes
Files. One license is required for each
UI. Can be used in WinCC OA Client
and Web Client. Maps are not
included. Dynamization performed
using Ctrl scripting.
6AV6352-1DC31-1AA0
WinCC OA S7 AdvancedLib
Runtime license for using the object
library WinCC OA S7 AdvancedLib,
coordinated with the SIMATIC object
library also supplied, which is free of
charge until revoked. License required
for each server.
6AV6352-1DD31-1AA0
6AV6352-1DE31-1AA0
WinCC OA Report 1 UI
Expands a WinCC OA Server
by 1 active Excel report process;
Microsoft Excel is not included.
6AV6352-1FA31-1AA0
WinCC OA Maintenance
Maintenance management for recording operating hours, switching cycles,
alarm handling and notepad function.
License required for each server.
6AV6352-1FB31-1AA0
WinCC OA Scheduler
Daily, weekly and monthly program, as
well as individual non-periodic events
with consideration of public holidays,
assignment of priority and override
function. License required for each
server.
6AV6352-1DF31-1AA0
WinCC OA Report 2 UI
Expands a WinCC OA Server
by 2 parallel active Excel report
processes; Microsoft Excel is not
included.
6AV6352-1FC31-1AA0
WinCC OA Recipe
Creation of any recipe types and recipes, acceptance of current process
values as recipe, activation/download
to data points, import and export
(Microsoft Excel). License required for
each server.
6AV6352-1DG31-1AA0
WinCC OA Report 5 UI
Expands a WinCC OA Server
by 5 parallel active Excel report
processes; Microsoft Excel is not
included.
WinCC OA Report 10 UI
Expands a WinCC OA Server
by 10 parallel active Excel report
processes; Microsoft Excel is not
included.
6AV6352-1FD31-1AA0
WinCC OA RDB
RDB Oracle connection for WinCC OA
Server S-UL. Oracle licenses are not
included. License required for each
server.
6AV6352-1DH31-1AA0
4/158
Excel report
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
■ Ordering data
Order No.
Communication Center
WinCC OA CommCenter 1
Basic package for 25 alarms. Output
as text message or e-mail is possible.
Price per WinCC OA Server.
6AV6352-1GA31-1AA0
WinCC OA CommCenter 2
Basic package for 250 alarms. Output
as text message or e-mail is possible.
Price per WinCC OA Server.
6AV6352-1GB31-1AA0
WinCC OA CommCenter 3
Basic package for 2,500 alarms. Output as text message or e-mail is possible. Price per WinCC OA Server.
6AV6352-1GC31-1AA0
WinCC OA CommCenter 4
Basic package for unlimited alarms.
Output as text message or e-mail is
possible. Price per WinCC OA Server.
6AV6352-1GD31-1AA0
Video management
Order No.
WinCC OA video driver RS 485TVI
Driver for controlling TVI pan-tilt
cameras. One license is required for
each WinCC OA Server.
6AV6352-1HK31-1AA0
WinCC OA video driver SNK
RS485 Funkwerk
Driver for controlling Funkwerk pan-tilt
cameras. One license is required for
each WinCC OA Server.
6AV6352-1HL31-1AA0
WinCC OA video driver SNK
RS485 Globe
Driver for controlling Globe pan-tilt
cameras.
One license is required for each
WinCC OA Server.
6AV6352-1HM31-1AA0
WinCC OA video driver SNK
development
Driver development for controlling
pan-tilt cameras
6AV6352-1HN31-1AA0
WinCC OA video driver
for cameras with RCP+ and H264
Drivers for controlling cameras with
RCP+ and H264.
One license is required for each
WinCC OA Server.
6AV6352-1HP31-1AA0
WinCC OA video driver dev.
Driver development for controlling
decoder/encoder/host protocols
6AV6352-1HQ31-1AA0
WinCC OA video driver Bosch
IntKey
Driver for controlling Bosch IntKey
console controller.
One license is required per server
6AV6352-1HR31-1AA0
WinCC OA Video driver development for console controllers
Driver development for controlling
console controllers
6AV6352-1HS31-1AA0
6AV6352-1HT31-1AA0
6AV6352-1HU31-1AA0
WinCC OA Video Light
Including 4 streams. Possible video
operator station configuration:
1 x quad image or 2 dual images or
4 single images. Not expandable with
further streams, redundancy not possible.
6AV6352-1HA31-1AA0
WinCC OA Video Basic
Including 7 streams. Possible video
operator station configuration: Display
in quad, dual or single images.
Expandable by additional streams,
redundancy is possible. One license is
required for each WinCC OA Server.
6AV6352-1HB31-1AA0
WinCC OA Video Extension
5 Streams
Extends WinCC OA Video Basic
by 5 streams
6AV6352-1HC31-1AA0
WinCC OA Video Extension
7 Streams
Extends WinCC OA Video Basic
by 7 streams
6AV6352-1HD31-1AA0
WinCC OA Video Extension
32 Streams
Extends WinCC OA Video Basic
by 32 streams
6AV6352-1HE31-1AA0
WinCC OA video driver Bosch VRM
(NVR)
Drivers for controlling Bosch video
recording equipment / NVR.
One license is required per server
WinCC OA Video Extension
128 Streams
Extends WinCC OA Video Basic by
128 streams
6AV6352-1HF31-1AA0
WinCC OA video driver development for recording equipment / NVR
Driver development for video recorder
equipment / NVR
WinCC OA Video Extension
256 Streams
Extends WinCC OA Video Basic
by 256 streams
6AV6352-1HG31-1AA0
WinCC OA Video Extension
512 Streams
Extends WinCC OA Video Basic
by 512 streams
6AV6352-1HH31-1AA0
WinCC OA video driver SNK
RS485 eneo
Driver for controlling eneo pan-tilt
cameras. One license is required for
each WinCC OA Server.
6AV6352-1HJ31-1AA0
4
HTTP server
WinCC OA HTTP Server
Forwarding of alarms, events and
WinCC OA information to the Internet
in HTML format including 1 HTTP connection.
6AV6352-1KA31-1AA0
WinCC OA HTTP Server Extension5
Extends the WinCC OA HTTP server
by 5 HTTP connections.
6AV6352-1KB31-1AA0
WinCC OA HTTP Server
Extension10
Extends the WinCC OA HTTP server
by 10 HTTP connections.
6AV6352-1KC31-1AA0
WinCC OA HTTP Server
Extension25
Extends the WinCC OA HTTP server
by 25 HTTP connections.
6AV6352-1KD31-1AA0
Siemens ST 80 / ST PC · 2013
4/159
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
■ Ordering data
Order No.
Kerberos
WinCC OA Secure
Extends a WinCC OA Server to include
protection by Kerberos.
Each WinCC OA Server requires a
separate WinCC OA Secure license.
6AV6352-1LA31-1AA0
AMS (Advanced Maintenance Suite)
4
AMS Starter Package 20A/E
This fully functional trial license
valid for 90 days includes the
AMS application as well as up to
20 A/E = 20 checklists assigned to
alarm/event DP. 1)2)3)
6AV6352-1MA31-1AA0
AMS Entry 20 A/E
The license includes the
AMS application as well as up to
20 A/E = 20 checklists assigned to
alarm/event DP. 1)2)3)
6AV6352-1MB31-1AA0
AMS Small 100 A/E
The license includes the
AMS application as well as
up to 100 A/E = 100 checklists
assigned to alarm/event DP. 1)2)3)
6AV6352-1MC31-1AA0
AMS Medium 1,000 A/E
The license includes the
AMS application as well as
up to 1,000 A/E = 1,000 checklists
assigned to alarm/event DP. 1)2)3)
6AV6352-1MD31-1AA0
AMS Large 5,000 A/E
The license includes the
AMS application as well as
up to 5,000 A/E = 5,000 checklists
assigned to alarm/event DP. 1)2)3)
6AV6352-1ME31-1AA0
■ More information
Additional information is available on the Internet at:
http://www.siemens.com/wincc-open-architecture
4/160
Siemens ST 80 / ST PC · 2013
Order No.
AMS Upgrade Large
The license contains an upgrade of
the AMS Large 5,000 A/E license with
1,000 A/E = 1,000 checklists assigned
to alarm/event DP.
6AV6352-1MF31-1AA0
AMS UL A/E
The license includes the AMS application as well as an unlimited number of
alarm/event DP checklist
assignments. 1)2)3)
6AV6352-1MG31-1AA0
AMS Client 2 UI
Operating station license for simultaneous use of no more than 2 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.
6AV6352-1MH31-1AA0
AMS Client 5 UI
Operating station license for simultaneous use of no more than 5 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.
6AV6352-1MJ31-1AA0
AMS Client 10 UI
Operating station license for simultaneous use of no more than 10 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.
6AV6352-1MK31-1AA0
1)
The basic price also includes the AMS Reports packages.
2)
AMS importer as well as 1 day of consulting for initial design by
ETM Consultants (excluding travel expenses) and 5 hours of telephone
support within 3 months after delivery.
3)
AMS Reports and AMS Importer, and 1 day of consulting for initial conceptualization by ETM consultants (not incl. travel costs). This license does not
include any support and cannot be expanded or extended.
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Overview
■ Benefits
• Process error diagnostics software for quick and precise
diagnosis of faults/errors in plants and machines for
SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various
SIMATIC components:
optimum interaction of STEP 7 engineering tools and
SIMATIC HMI
• Standardized user interface
• Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• ProAgent:
- Provides optimum support for plant and machine personnel
in respect of troubleshooting and fault rectification
- Increases plant availability
- Reduces downtimes
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time
• No special operator know-how is required thanks to clearly
comprehensible indication of the cause of error
■ Application
Increased productivity is being achieved more and more by
cutting costs.
In this context, the focus is increasingly on maintenance.
The emphasis here is on rectifying faults as quickly and
efficiently as possible.
G_ST80_XX_00367
67(3
Process error diagnostics with ProAgent for WinCC flexible /ProAgent
and with the STEP 7 engineering tools
Ideally, the operating personnel should also perform part of the
maintenance tasks. The operating personnel are on-site, they
are familiar with the procedures and can intervene quickly. This
saves time and reduces costs. It is precisely here that ProAgent
can assist operating personnel in identifying faults quickly, in
particular in the automotive and machine tool industries.
In the event of a process fault, process fault diagnostics with
SIMATIC ProAgent will provide information about the location
and cause of that fault and support personnel with troubleshooting.
The ProAgent solution has been optimized specifically for use
with SIMATIC S7-300/S7-400 and SIMATIC WinAC.
It can be used in combination with the S7-PDIAG, S7-GRAPH
and S7-HiGraph1) STEP 7 engineering tools. The ProAgent
option package features standard displays that are updated with
process-specific data during runtime.
1)
Process diagnostics with S7-HiGraph in combination with
TP/OP/MP 270/277, MP 370/377, and C7636 and PC RT systems.
3B67B;;B
67(3
Process error diagnostics with WinCC/ProAgent and the STEP 7
engineering tools
Siemens ST 80 / ST PC · 2013
4/161
4
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Function
• Context-sensitive diagnostics initiation due to process error
message
• Output of operands with symbols and comment
• Switching is possible between LAD, STL and signal list
• Supporting fault rectification with direct process access when
using the motion display
• Output of the faulty operands directly in the message
including address, symbol and comment 1)
• Consistency test in RT:
Inconsistent diagnostic units are marked with icons. This
permits quick locating of faults regarding configured data in
the commissioning phase.
• Direct, unit-related entry point in the diagnostic display from
user displays by using ProAgent functions
• Unit or message-related entry to STEP 7 (LAD/STL/FD editor,
S7-GRAPH, HW CONFIG (upon system error messages)),
supported fully automatically 2)
• Unit or message-related entry to STEP 7),
supported fully automatically 3)
• Graphic display of step sequences (overview display) 4)
4
1)
In combination with TP/OP/MP 270/277, MP 370/377, C7 636,
WinCC/ProAgent as of V6.0, and WinCC flexible /ProAgent
2)
WinCC/ProAgent as of V5.5 and as of WinCC flexible 2007 /ProAgent
on PC RT
3)
Only WinCC/ProAgent as of V5.5
4)
As of WinCC flexible 2007 /ProAgent, WinCC/ProAgent as of V5.6 in
combination with S7-GRAPH as of V5.1 (OCX is delivered as of
S7-GRAPH 5.1)
Standardized user interface with standard displays
• Message display
• Unit overview
• Diagnostics detail display
• Motion display
• Sequencer operating display
The displayed image contents are related to the previously
selected units or messages. This means that the proper. contextsensitive diagnostics display can be called up based on a
message or a selected technological unit.
4/162
Siemens ST 80 / ST PC · 2013
Message display
All of the existing process messages are shown in the message
display. Context-sensitive branching to other diagnostic
displays is also possible with a selected message. The
operating personnel can also take the message directly from the
erroneous operands and react immediately without having to
perform any other operations on the HMI device. WinCC flexible
permits this function on the Windows CE-based devices
TP/OP/MP 270/277, MP 370/377, and on PC Runtime systems.
The function is available as of version 6.0 for WinCC/ProAgent.
Unit overview
The units overview displays all technological units and the
respective sub-units (system/machine components) in table
form. In this display, the user is able to recognize, for example,
which operating mode or which status the respective unit is in.
The operating mode can be changed by the user if required.
Faulty units are marked with attributes.
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Function (continued)
Diagnostics detail display
Sequencer operating display
The diagnostic detail display shows the faulty operands at the
time of origination of a process error. As an option, current status
information can also be displayed. The diagnostics results are
either displayed in a ladder diagram (LAD), statement list (STL),
or in a clearly arranged signal list overview. The output of the
operands depends on the display format with symbols and
comments from the S7 symbol table. Only the operands that
cause the fault are displayed and marked with a highlighted
attribute. Switching to a display that calls up the current status of
all operands in the controller is also possible.
The sequencer operating display supports sequencer control.
This makes functions such as initializing and acknowledging
sequencers, activating/deactivating individual steps and
operating mode settings possible analog to the status/control in
S7-GRAPH.
The steps are output to a list with step number/name. Attributes
for identifying an active/faulty step give the operating personnel
an overview of the current status of the step sequence.
4
Motion display
Sequencer diagnostic display
The motion display is used for supported fault rectification. Every
motion line contains a comment line that describes the motion
(e.g. x-axis), two actions for implementing the motion, response
concerning the actuation of a motion and information on the
respectively achieved end positions (max. 16).
WinCC flexible/ProAgent and WinCC/ProAgent1) also offer
capabilities for graphic monitoring and sequencer diagnostics.
This gives the user the ability to monitor active/faulty steps as
well as the fault cause, e.g. faulty transition conditions, simultaneously on the HMI device.
The motion itself is controlled with softkeys on the side of
SIMATIC Panels and Multi Panels. For time-critical motions, the
actuation can be done directly through inputs of the controller
(depending on the capabilities of the target hardware:
24 V direct keys, DP direct keys via PROFIBUS).
1)
WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1
(OCX is delivered as of S7-GRAPH 5.1)
Siemens ST 80 / ST PC · 2013
4/163
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Technical specifications
Interfaces
• Can be used in conjunction with
programmable controllers:
• Types of connection
WinCC/ProAgent
WinCC flexible /ProAgent
SIMATIC S7:
S7-300/S7-400; WinAC
SIMATIC S7 Protocol Suite:
MPI, PROFIBUS DP, Industrial Ethernet, TCP/IP
SIMATIC S7:
S7-300/S7-400; WinAC
SIMATIC S7 Protocol Suite:
MPI, PROFIBUS DP,
PROFINET IO, Industrial Ethernet, TCP/IP
Display units
Standard images for:
Number of languages for
online language selection
Standard displays for easy embedding in user displays,
example project for MP 377
3 (de/en/fr)
5 (de/en/fr/it/es)
Modification of HMI diagnostics data
management in RT
WinCC/ProAgent V6.0 and higher
No
Unit overview
Yes
Yes
Message display
Yes
Yes
Sequencer operating display
Yes
Yes
Diagnostics detail display
• Display
STL/LAD/signal list
• Display of operands with symbol and
comment
Yes
Yes/Yes/Yes
Yes
Yes/Yes/Yes
Yes
Yes
Criteria analysis
When fault occurs/current status/can be archived
When fault occurs/current status
6
6
2
16
2
16
de/en/fr; included in scope of delivery
de/en/fr/it/es; included in scope of delivery
HMI software
WinCC V7.0 SP3
(ProAgent V7.0 SP3)
WinCC flexible 2008
Operating system:
Configuration
WinCC/ProAgent V7.0 + SP2:
Windows Professional SP3, Windows 7 (32 bit) Ultimate,
Business, and Enterprise
WinCC flexible /ProAgent 2008 + SP2:
Windows XP SP3,
Windows 7 Professional,
Ultimate, Enterprise
Operating system
Runtime
WinCC/ProAgent V7.0 + SP2:
Windows XP Professional SP3,
Windows 7 (32 bit) Ultimate, Business and Enterprise,
Windows 2003 Server SP2, Windows 2008 Server SP2
WinCC flexible /ProAgent for SIMATIC Panels:
WinCC flexible /ProAgent for WinCC flexible Runtime:
Windows XP SP3,
Windows 7 Professional, Ultimate, Enterprise
STEP 7
• S7-GRAPH
• S7-PDIAG
• S7-HiGraph
V5.4 SP4 and higher
V5.3 SP6 and higher
V5.3 SP3 and higher
No
V5.3 and higher
V5.2 + SP3 and higher
V5.1 and higher
V5.3 and higher
Type of delivery
(one license is required for each target
hardware)
CD-ROM / Runtime license
Runtime license
Functionality
4
Motion display
• Number of viewable
movements
• Directions of motion
• Number of viewable
end positions per movement
Documentation
In electronic format
Requirements
4/164
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
■ Ordering data
Order No.
Order No.
Documentation
(must be ordered separately)
SIMATIC WinCC/ProAgent
Software option package for
process error diagnostics based
on S7 GRAPH V5 and higher and
S7 PDIAG V5 and higher;
functional enhancement for
SIMATIC WinCC;
electronic documentation in English,
French and German;
functions and standard screens for
use on a PC (resolution 1024 x 768
pixel) and Panel PC 577/677/
877 15" (resolution 1024 x 768 pixel)
in English, French and German,
Runtime license (single license)
WinCC version:
SIMATIC HMI Manual Collection
6AV6691-1SA01-0AX0
Electronic documentation
on CD-ROM
5 languages (English, German,
French, Italian and Spanish);
contains: all currently available
user manuals, device manuals
and communication manuals for
SIMATIC HMI
• V7.0 SP3; for WinCC V7.0 SP3 1)
6AV6371-1DG07-0AX0
Upgrade
• to V7.0 SP3 1)
6AV6371-1DG07-0AX4
SIMATIC WinCC flexible /ProAgent
Software option package for process error diagnostics based on
S7 PDIAG V5.1 and higher,
S7 GRAPH V5.2 + SP3 and higher;
S7 HiGRAPH V5.3 and higher.
Functional enhancement for
SIMATIC WinCC flexible; electronic
documentation in English, French,
German, Italian and Spanish
• WinCC flexible /ProAgent
for SIMATIC Panels
Runtime license (Single License)
executable on TP/OP/MP 270/277,
Mobile Panel 277 and MP 370/377
• WinCC flexible /ProAgent
for WinCC flexible Runtime
Runtime license (single license)
4
6AV6618-7DB01-3AB0
6AV6618-7DD01-3AB0
1)
Not multi-station-capable
Siemens ST 80 / ST PC · 2013
4/165
© Siemens AG 2013
HMI Software
Notes
4
4/166
Siemens ST 80 / ST PC · 2013
5
© Siemens AG 2013
PC-based Automation
5/2
SIMATIC Industrial PC
5/3
5/7
5/13
5/20
Rack PC
SIMATIC IPC547D
SIMATIC IPC647C
SIMATIC IPC847C
5/27
5/30
5/36
5/39
5/44
5/47
Box PC
SIMATIC IPC227D
SIMATIC IPC427D
SIMATIC IPC427C
SIMATIC IPC627C
SIMATIC IPC827C
5/50
5/53
5/58
5/63
5/67
5/71
SIMATIC Panel PC
SIMATIC IPC277D
SIMATIC IPC477D
SIMATIC HMI IPC477C
SIMATIC HMI IPC577C
SIMATIC HMI IPC677C
5/76
5/77
5/84
5/90
5/167
5/167
5/168
5/168
5/169
5/169
Input and output devices
SIMATIC PC keyboard
IP65 membrane keyboard, desk version
IP65 membrane keyboard,
19" built-in version
19" slide-in keyboard PS/2 with trackball
SIMATIC IPC mouse
5/170
5/171
5/171
5/172
5/172
5/173
SITOP power supplies
1-phase, 24 V DC/10 A (SITOP PSU100S)
1-phase, 24 V DC/20 A (SITOP PSU100S)
3-phase, 24 V DC/10 A (SITOP PSU300S)
3-phase, 24 V DC/20 A (SITOP PSU300S)
3-phase, 24 V DC/40 A (SITOP PSU300S)
5/174
24 V DC uninterruptible power supplies
5/176
5/177
5/178
DC UPS with capacitors
SITOP UPS500S
SITOP UPS500P
SIMATIC PC-based controllers
SIMATIC WinAC RTX
SIMATIC WinAC RTX F
SIMATIC WinAC ODK
5/179
5/181
5/91
5/93
5/100
Embedded Controller
EC31
Expansion modules
5/183
5/101
5/102
5/103
5/104
5/108
5/109
5/110
5/114
Embedded bundles/Software packages
SIMATIC IPC227D bundles
SIMATIC IPC427D bundles
SIMATIC IPC427C bundles
SIMATIC IPC277D bundles
SIMATIC IPC477D bundles
SIMATIC HMI IPC477C bundles
Software packages for SIMATIC IPC
and S7-mEC
DC UPS with battery modules
DC UPS module 6 A,
DC UPS module 15 A
DC UPS module 40 A,
Battery module 1.2 Ah
Battery module 2.5 Ah,
Battery module 3.2 Ah
Battery module 7 Ah,
Battery module 12 Ah
5/117
5/117
5/120
5/130
5/134
5/136
5/139
5/143
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel MT
SIMATIC Industrial Flat Panel
SIMATIC Flat Panels
SCD desk monitors SCD 19101
SCD monitors 1900
SIMATIC Industrial Thin Client
SIMATIC Thin Client
5/146
5/147
5/149
5/150
5/151
5/152
RMOS3 real-time operating system
RMOS3 V3.50 real-time operating system
RMOS3-GNU V3.0
RMOS3-TCP/IP V3.0
RMOS3-GRAPHX V1.0
BSP SIMATIC IPC V4.0 for RMOS3
5/153
5/155
5/155
5/156
5/161
5/163
5/164
5/165
5/166
Expansion components / accessories
SIMATIC IPC CompactFlash
SIMATIC IPC (Service) USB FlashDrive
PC I/O
SIMATIC Panel PC Remote Kit
SIMATIC IPC Image & Partition Creator
SIMATIC IPC DiagMonitor
SIMATIC IPC Remote Manager
SIMATIC IPC BIOS Manager
5/182
5/184
5/185
MASTERGUARD power supply
5/186
5/186
5/187
5/188
5/189
5/191
5/192
5/193
5/194
5/196
5/198
5/199
5/201
5/203
5/205
5/206
5/207
Communication – Industrial Ethernet
Connection options to SIMATIC IPCs
CP 1604
CP 1616
CP 1612 A2
CP 1613 A2
CP 1623
CP 1628
HARDNET-IE S7-REDCONNECT
SOFTNET for Industrial Ethernet
SOFTNET-IE RNA
SOFTNET PN IO
OPC server for Industrial Ethernet
PN CBA OPC server
S7 OPC Redundancy
for Industrial Ethernet
SNMP OPC server
SINEMA server
5/208
5/208
5/209
5/211
5/213
5/215
5/217
5/219
5/221
5/223
5/225
5/227
5/229
5/230
Communication – PROFIBUS
Connection options to SIMATIC IPCs
CP 5603
CP 5613 A2
CP 5614 A2
CP 5623
CP 5624
CP 5512
CP 5612
CP 5622
CP 5711
SOFTNET for PROFIBUS
OPC server for PROFIBUS
S7 OPC Redundancy for PROFIBUS
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
SIMATIC Industrial PC
Industrial PC
■ Overview
Industrial PC
Our reliable and innovative industrial PCs are the optimal
PC hardware platform for PC-based Automation from Siemens.
Rack PC
Rack PCs are flexible, high-availability industrial PC systems for
powerful yet compact applications using 19" technology.
Box PC
SIMATIC Box PCs provide mechanical engineers, plant
engineers and control cabinet makers with particularly rugged
industrial PC systems for use in powerful yet compact applications.
5
Ruggedness and industrial compatibility
for 24-hour continuous use in an industrial environment
• Compact, space-saving enclosure (Box PC and Panel PC)
• Suitable for installing in space-saving control cabinets, only
500 mm deep (Rack PC)
• All-metal enclosure with a high degree of electromagnetic
compatibility for use in industrial areas and in domestic,
business and commercial environments and for a degree of
protection up to IP65/NEMA 4
• The mounting position of the devices can be varied by means
of wall, portrait or control cabinet mounting (Box PC), rail
mounting (SIMATIC IPC427D or IPC227D only) and horizontal
or vertical mounting position in the 19" cabinet or with the
appropriate kit as an industrial tower PC (Rack PC).
• High resistance to shock/vibration thanks to special hard disk
mountings, locked connectors, and card retainers
• Maintenance-free, due to design without hard disk and fans
using SIMATIC CompactFlash cards or solid-state drive
(SIMATIC IPC427D/IPC477D and SIMATIC IPC227D/
IPC277D)
• Service-friendly, modular device design for replacement of
defective components
• Integral industrial power supplies (according to NAMUR) for
safe power supplies protected against system disturbances
• Attractive product design with dirt-repelling fronts and coated
surfaces
• Dust protection thanks to a pressurized cooling concept, frontmounted fans and dust filters (Rack PC)
■ More information
Notes on the scope of delivery
Panel PC
Microsoft operating systems are pre-installed in an OEM version.
SIMATIC Panel PCs are suitable thanks to their high industrial
compatibility for use in control cabinets, consoles and control
panels, as well as directly on the machine. Typical areas of application can be found in both factory and process automation.
The scope of supply also includes:
• Recovery CD for simple reinstallation of the operating system
(not for Windows Embedded)
• Restore DVD (hard disk image) for fast and very easy
restoration of the PC delivery status
• SIMATIC IPC Documentation and Drivers DVD
• Compact Operating Instructions
(German/English/French/Spanish/Italian/Chinese)
• Electronic manual on IPC Documentation and Drivers DVD
(German/English)
Industrial monitors and thin clients
Flexible operator input concepts can be implemented via Flat
Panel monitors or thin clients. These are industry-standard LCD
monitors with high-contrast displays that can be located up to
30 m away from the PC, or low-cost, rugged thin clients that offer
HMI functionality over the network in larger plants spread over
wide areas.
Further information can be found in the Internet at:
http://www.siemens.com/simatic-ipc
Information material for ordering and for downloading is
available on the Internet:
http://www.siemens.com/simatic/printmaterial
5/2
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Rack PC
Rack PC
■ Overview
Rack PCs are flexible, high-availability industrial PC systems for
powerful yet compact applications using 19" technology.
Three device classes are available for various requirements:
SIMATIC IPC547 – maximum performance at an attractive price
SIMATIC IPC647 – maximum compactness combined with
maximum industrial functionality
SIMATIC IPC847 – maximum expandability and industrial
functionality
Shared industrial functionality
• Maximum system performance for complex automation tasks
and computationally intensive PC tasks in the industrial
environment through use of Intel Core processors
• Designed for 24-hour continuous operation
• Monitoring and diagnostics functions
(e.g. temperature, fan, watchdog)
• RAID1 configuration (mirrored drives), optionally in "hot swap"
frames
• Hard disks with capacities up to 1 TB for large volumes of data
• Solid-state drive (SSD) with SLC technology, optional
• Compact dimensions for installation in control cabinets only
500 mm deep
• Dust protection thanks to overpressure ventilation concept
with fan on the front and dust filter
• Lockable front panel or front door
• Service-friendly equipment design due to prepared telescopic
rail mounting
• Universal implementation as an industrial workstation or
server
• Operating system preinstalled and activated for fast startup
• Fast restoration of the delivery status of the HDD thanks to
restore DVD
• High flexibility and expandability of components
• PCI and PCI Express expansion slots
• Independent industrial product design
5
Siemens ST 80 / ST PC · 2013
5/3
© Siemens AG 2013
PC-based Automation
Rack PC
Rack PC
■ Overview (continued)
SIMATIC IPC547D –
maximum performance at an attractive price
• Intel Core i processors 2nd generation
• Maximum processor performance in maximum configuration
without loss of power (throttling) at ambient temperatures of up
to 40 °C
• Optional RAID5 configuration (striping with parity) in
"hot swap" frames
• Redundant AC power supply, optional
• Low noise output thanks to controlled fans
• Status and alarm LEDs at the front for signaling critical system
states
• Availability for at least 1.5 years
• Guaranteed spare parts availability for at least 3 years
5
SIMATIC IPC647C – maximum compactness combined with
maximum industrial functionality
• Maximum compactness due to 3 free PCI/PCI Express slots
for installing long expansion cards and integrated interfaces
for communication, e.g. integrated PROFIBUS/MPI or
PROFINET interface
• High thermal stability up to 50°C even at maximum processor
performance
• High vibration/shock resistance thanks to special hard disk
holders
• Intel Core i processors
• Enhanced server functionality:
Hardware RAID PCIe x8 controller with zero-maintenance
cache protection module, SAS hard disks in hot-swap frame
with capacities up to 1 TB for large volumes of data
• Redundant AC power supply, optional
• ECC memory, optional
• Service-friendly device design due, for example, to the
replacement of filters/fans from the front without the need for
tools, or opening of the enclosure with just one screw.
• Front LED concept for efficient self-diagnostics, e.g.
monitoring of the hard disks in RAID1 configurators, fans or
the status display for Ethernet, PROFINET and PROFIBUS.
• Integrated PROFIBUS DP/MPI or PROFINET interface
(optional)
• High continuity of the components/design
• Motherboard developed and manufactured by Siemens
• Availability for up to 6 years
• Guaranteed spare parts availability for at least 5 years
5/4
Siemens ST 80 / ST PC · 2013
SIMATIC IPC847C – maximum expandability and industrial
functionality
• Maximum expandability due to 11 free PCI/PCI Express slots
for installing long expansion cards and integrated interfaces
for communication, e.g. integrated PROFIBUS/MPI or
PROFINET interface
• High thermal stability up to 50°C even at maximum processor
performance
• High vibration/shock resistance thanks to special hard disk
holders
• Intel Core i processors
• Optional RAID5 configuration (striping with parity)
in "hot swap" frames
• Extended server functionality:
Hardware RAID PCIe x8 controller, SAS hard disks in hot-swap
frame with capacities up to 1 TB for large volumes of data
• Redundant AC power supply, optional
• SATA hard disks with capacities up to 500 GB for large
volumes of data
• ECC memory, optional
• Service-friendly device design due, for example, to the
replacement of filters/fans from the front without the need for
tools, or opening of the enclosure with just one screw.
• Front LED concept for efficient self-diagnostics, e.g.
monitoring of the hard disks in RAID1 configurators, fans or
the status display for Ethernet, PROFINET and PROFIBUS.
• Integrated PROFIBUS DP/MPI or PROFINET interface
(optional)
• High continuity of the components/design
• Motherboard developed and manufactured by Siemens
• Availability for up to 6 years
• Guaranteed spare parts availability for at least 5 years
© Siemens AG 2013
PC-based Automation
Rack PC
Rack PC
■ Overview (continued)
SIMATIC IPC547D
SIMATIC IPC647C
SIMATIC IPC847C
19" rack
4 HU
2 HU
4 HU
Prepared for telescopic rails
•
•
•
Horizontal/vertical installation
•/•
•/-
•/•
19" mounting bracket can be removed
from outside
•
•
•
Tower Kit (optional)
•
-
•
Processor
• Intel Core i7-2600
(4C/8T, 3.40 GHz)
• Intel Core i5-2400
4C/4T, 3.10 GHz)
• Intel Pentium G850
(2C/2T, 2.90 GHz)
• Intel Core i7-610E
(2C/4T, 2.53 GHz)
• Intel Core i5-520E
(2C/4T, 2.4 GHz)
• Intel Core i3-330E
(2C/4T, 2.13 GHz)
• Intel Core i7-610E
(2C/4T, 2.53 GHz)
• Intel Core i5-520E
(2C/4T, 2.4 GHz)
• Intel Core i3-330E
(2C/4T, 2.13 GHz)
Main memory
• 1 GB, expandable up to 32 GB
• 1 GB, expandable up to 8 GB
• ECC optional
• 1 GB, expandable up to 8 GB
• ECC optional
Slots for expansions
(all long, up to 312 mm)
•
•
•
•
• 2 x PCI
• 1 x PCI Express x16
• 7 x PCI
• 1 x PCI Express x16
• 3 x PCI Express x4
Design
General features
4 x PCI
1 x PCI Express x16
1 x PCI Express x16 (4 lanes)
1 x PCI Express x8
(1 lane)
or
• 1 x PCI
• 1 x PCI Express x8 (4-lane)
• 1 x PCI Express x16
or
• 7 x PCI
• 1 x PCI Express x16
Onboard graphics
• 1 x DisplayPort
• 1 x DVI-I
• 1 x VGA
(via adapter cable, optional)
• 1 x DVI-I
• 1 x VGA
(via adapter cable, optional)
• 1 x DVI-I
• 1 x VGA
(via adapter cable, optional)
Graphics card (optional)
• PCI Express x16
(2 x VGA or 2 x DVI-D)
• PCI Express x16
(2 x VGA or 2 x DVI-D)
• PCI Express x 16
(2 x VGA or 2 x DVI-D)
without
•
•
•
Preinstalled and activated,
supplied on restore DVD
• Windows XP Professional
Multi-Language (32-bit)
• Windows 7 Ultimate Multi-Language
(32/64-bit)
• Windows Server 2008 incl. 5 Client
Multi-Language (32-bit)
• Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)
• Windows XP Professional
Multi-Language (32-bit)
• Windows 7 Ultimate Multi-Language
(32/64-bit)
• Windows Server 2003 R2 incl.
5 Clients Multi-Language (32-bit)
• Windows Server 2008 incl. 5 Clients
Multi-Language (32-bit)
• Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)
• Windows XP Professional
Multi-Language (32-bit)
• Windows 7 Ultimate Multi-Language
(32/64-bit)
• Windows Server 2003 R2 incl.
5 Clients Multi-Language (32-bit)
• Windows Server 2008 incl. 5 Clients
Multi-Language (32-bit)
• Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)
Order separately
-
RMOS3 V3.50
RMOS3 V3.50
Project-specific on request
• Linux 1)
• Other
• Linux 1)
• Other
• Linux 1)
• Other
PROFIBUS/MPI
-
12 Mbit/s (CP 5611-compatible),
optional
12 Mbit/s (CP 5611-compatible),
optional
PROFINET
-
3 x RJ45 (CP 1616-compatible),
optional
3 x RJ45 (CP 1616-compatible),
optional
Ethernet
2 x 10/100/1000 Mbit/s
2 x 10/100/1000 Mbit/s
2 x 10/100/1000 Mbit/s
USB 2.0 (high current)
11 x, 2 of which at front, 1 x internal
7 x , 2 of which at front, 1 x internal
7 x , 2 of which at front, 1 x internal
VGA
• optional
• optional
• optional
DVI
•
•
•
DisplayPort
•
-
-
Operating system
Interfaces
Siemens ST 80 / ST PC · 2013
5/5
5
© Siemens AG 2013
PC-based Automation
Rack PC
Rack PC
■ Overview (continued)
SIMATIC IPC547D
SIMATIC IPC647C
SIMATIC IPC847C
•
•
•
•
•
-
•
•
RAID1/5 configuration
with onboard RAID
•/•
•/-
• /•
Solid-state drive (SSD), SLC
•
•
•
Installation at the front in the swap
frame
-
•
•
RAID1/5 configuration with HW RAID
controller PCI x 8 incl. zero maintenance cache protection module
-/-
•/-
• /•
DVD-ROM
•
-
•
DVD±R/RW
•
•
•
AC power supply
•
•
•
Redundant (optional)
•
•
•
Vibration/shock load
during operation
0.2 g / 1 g
0.5 g / 5 g
0.5 g / 5 g
Ambient temperature
during operation
With maximum configuration:
5 ... 40 °C
With maximum configuration:
5 ... 50 °C
With maximum configuration:
5 ... 50 °C
Drives
SATA hard disks
• Internal installation
• Installation at the front in the swap
frame
• Internal installation in drive holder
(shock and vibration-damped)
Hard disks SAS
Optical drives
Ambient conditions 2)
• Available
- Not available
5
1)
Suitable for specific Linux versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for Linux", see
http://www.siemens.com/simatic-pc/suited-for-linux
(Linux is a trademark of Linus Torvald)
2)
Restrictions when using DVD±R/RW and hard disks in swap frame.
■ More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
Information material can be ordered or downloaded from the
Internet:
http://www.siemens.com/simatic/printmaterial
5/6
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
■ Overview
■ Technical specifications
SIMATIC IPC547D
General features
Design
19" rack, 4 HU, externally painted
Processor
• Intel Core i7-2600
(4C/8T, 3.40 GHz, 8 MB Last Level
Cache, Turbo Boost 2.0, EM64T,
VT-x/-d, iAMT)
• Intel Core i5-2400
(4C/4T, 3.10 GHz, 6 MB Last Level
Cache, Turbo Boost 2.0, EM64T,
VT-x/-d, iAMT)
• Intel Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT)
Chipset
• Intel Q67
Main memory
•
•
•
•
From 1 GB DDR3 1333 SDRAM
Dual channel support
4 DIMM base
Expandable up to 32 GB 1)
Spare slots for expansions (all long)
•
•
•
•
4 x PCI
1 x PCI Express x16
1 x PCI-Express x16 (4 lanes)
1 x PCI-Express x8 (1 Lane)
Graphics
• Onboard Intel HD 2000 graphics
controller integrated into the processor; Shared Video Memory up
to 1.7 GB; up to 2560 x 1600 pixels at 60 Hz image refresh rate
and 32-bit colors
• PCI Express graphics card (Dual
Head: 2 x VGA or 2 x DVI-D) in the
PCIe x16 slot; 512 MB; up to
2048 x 1536 pixels at 85 Hz image refresh rate and 32 bit colors
(optional)
Operating system
• without
The SIMATIC IPC547D is a rugged industrial PC in 19" rack
design (4 HU).
It offers:
• Maximum performance
• Attractive price
• Intel Core i technology
Preinstalled and activated
(supplied on restore DVD):
• Windows XP Professional MUI
(32-bit)
• Windows 7 Ultimate MUI
(32/64-bit)
• Windows Server 2008 incl.
5 Client MUI (32 bit)
• Windows Server 2008 R2 incl.
5 Client MUI (64 bit)
MUI (Multilanguage User Interface,
5 languages): English, German,
French, Italian, Spanish
Project-specific on request:
• Linux 2)
• Other
Power supply
• 100 ... 240 V AC, 50 ... 60 Hz, with
bridging of short-term power failures: max. 20 ms at 0.85% rated
voltage
• Redundant 100 ... 240 V AC,
50 ... 60 Hz
1)
Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.
2)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
Siemens ST 80 / ST PC · 2013
5/7
5
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
■ Technical specifications (continued)
SIMATIC IPC547D
Drives
SIMATIC IPC547D
Monitoring functions
Hard disk, SATA 3.5"
with NCQ technology
Solid State Drive, SATA 2.5"
with SLC technology
Installation in internal drive support
• 500 GB
• 1 TB
• RAID1 3) 1 TB
(2 x 1 TB, mirror disks)
• 50 GB solid-state drive
Installation at the front in swap
frame (low profile)
• 500 GB
• 2 x 500 GB
• RAID1 3) 1 TB (2 x 1 TB, mirror
disks), "hot swap"
• RAID5 3) 2 TB (3 x 1 TB, striping
with parity), "hot swap"
• 50 GB solid-state drive
• RAID1 3) 1 TB (2 x 1 TB, mirror
disks), "hot swap" + 50 GB solidstate drive (operating system installed on SSD if configured)
DVD-ROM, 5.25", SATA
• 16 x (DVD media)
• 32 x (CD media)
DVD±R/RW, 5.25", SATA
• 16 x 24 x 8 x (DVD media)
• 48 x 48 x 32 x (CD media)
Slots for drives
Front:
• 3 x 5.25"
• 1 x 3.5"
Basic functionality
Message locally
via DiagBase software
Temperature
When permitted operating temperature range is exceeded
Fan
Speed monitoring
• 1 x front fan
• 1 x CPU fan
• 1 x power supply fan
Watchdog
• Monitoring of program execution
• Monitoring time can be parameterized in software
Monitoring functions via the network
SIMATIC IPC DiagMonitor Version
V4.3.x.x or higher (optional)
Remote monitoring capability for:
• Watchdog
• Temperature
• Fan speed
• Battery
• Hard disks (SMART)
• System/Ethernet
Communication:
• Ethernet interface
(SNMP protocol)
• OPC for integration
in SIMATIC software
• Client server architecture
• Structure of log files
Internal:
• 2 x 3.5"
Front LEDs
Interfaces
5
Ethernet
2 x Intel Gbit Ethernet
(RJ45, teaming-capable)
USB 2.0
• 2 x front (high current)
• 8 x rear (high current)
• 1 x internal (high current),
e.g. for USB dongle with
optional interlocking
Serial
9-pole COM1 (V.24);
COM2 (V.24) (optional)
Parallel
LPT (optional)
VGA
Optionally via adapter cable
DVI-I
1x
DisplayPort
1x
Keyboard
PS/2
Mouse
PS/2
Audio
1 x Line In; 1 x Line Out; 1 x Micro
3)
SATA RAID controller onboard in Intel Q67 chipset
4)
Restrictions in use of optical drives and HDD in swap frames.
5/8
Siemens ST 80 / ST PC · 2013
•
•
•
•
POWER (PC switched on)
HDD (access to hard disk)
TEMP (temperature monitoring)
FAN (fan monitoring)
Additional HDD alarm LEDs for
RAID configurations behind the
front flap
Ambient conditions
Degree of protection
IP30 front, IP20 rear according to
EN 60529
Dust protection
With the front door closed according to IEC 60529 filter class G2
EN 779, 99% of particles > 0.5 mm
are filtered
Protection class
Protection class I according to
IEC 61140
Vibration load during operation 4)
IEC 60068-2-6, 10 cycles
• 20 ... 58 Hz: 0.015 mm
• 58 ... 200 Hz: 2 m/s2
(approx. 0.2 g)
Shock load in operation 4)
IEC 60068-2-27
• Half-sine: 9.8 m/s2, 20 ms
(approx. 1 g),
100 shocks per axis
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
■ Technical specifications (continued)
SIMATIC IPC547D
Electromagnetic compatibility (EMC)
Emitted interference
SIMATIC IPC547D
Approvals and safety regulations
EN 61000-6-3; EN 61000-6-4;
CISPR 22 / EN 55022 Class B;
FCC Class A;
EN 61000-3-2 Class D;
EN 61000-3-3
Immunity to conducted interference on
the supply lines
• ± 2 kV (IEC 61000-4-4, burst)
• ± 1 kV
(IEC 61000-4-5, symm. surge)
• ± 2 kV
(IEC 61000-4-5, asymm. surge)
Immunity to interference on signal lines
• ±2 kV (IEC 61000-4-4, burst,
length > 30 m)
• ± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
• ± 2 kV (IEC 61000-4-5, surge,
length > 30 m)
Immunity to static discharge
• ± 4 kV, contact discharge
(IEC 61000-4-2)
• ±8 kV, air discharge
(IEC 61000-4-2)
Immunity to high radio frequency interference
• 1 V/m 80% AM; 2 ... 2.7 GHz
(IEC 61000-4-3)
• 10 V/m 80% AM;
80 MHz ... 1 GHz and
1.4 GHz … 2 GHz
(IEC 61000-4-3);
• 10 V, 10 kHz ... 80 MHz
(IEC 61000-4-6)
Immunity to magnetic fields
100 A/m, 50/60 Hz (IEC 61000-4-8)
Ambient temperature during operation
5 ... 40 °C
Safety regulations
IEC 60950-1; UL60950; CSA
Approvals
cULus 60950
CE mark
For use in industrial areas as well
as domestic, business and commercial environments:
• Emitted interference:
EN 61000-6-3:2007
• Noise immunity:
EN 61000-6-2:2005
Dimensions and weights
Mounting dimensions (W x H x D)
in mm
434 x 177 x 446
Weight, approx.
19 kg
Note:
Limitations for operation
of DVD±R/RW
Humidity during operation
5 ... 80% at 25 °C
(no condensation)
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations.
Siemens ST 80 / ST PC · 2013
5/9
5
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
■ Ordering data
SIMATIC IPC547D
Order No.
1)
Order No.
6AG4104- 2 7 7 7 7 - 7 7 7 7
Interfaces:
2 x Gbit Ethernet (RJ45),
1 x DisplayPort, 1 x DVI-I,
8 x USB on the rear,
2 x USB on the front,
1 x USB internal,
1 x serial (COM1), 2 x PS/2,
audio; 7 slots (all long):
4 x PCI, 1 x PCIe x16,
1 x PCIe x16 (4 lanes),
1 x PCIe x8 (1 lane);
mounting locations:
6 (3 x 5.25", 1 x 3.5" externally
accessible; 2 x 3.5" internal);
temperature and fan monitoring;
watchdog; card retainer
Processors
• Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT)
• Core i5-2400 (4C/4T, 3.10 GHz,
6 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT)
• Core i7-2600 (4C/8T, 3.40 GHz,
8 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT)
5
Drives
• 500 GB HDD SATA; internal
• 1 TB HDD SATA; internal
• RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks); internal 2)
• 50 GB solid-state drive (SLC)
SATA; internal
• 500 GB HDD SATA in swap frame;
front
• 2 x 500 GB HDD SATA in swap
frame; front
• RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame; for hot
swapping; at the front
• RAID5, 2 TB (3 x 1 TB HDD SATA,
striping with parity) in swap frame;
for hot swapping; at the front
• 50 GB solid-state drive (SLC) SATA
in swap frame; at the front
• RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame; hot
swapping; at the front + 50 GB solid-state drive (SLC) SATA in swap
frame; at the front (operating system installed on SSD, if configured)
Memory configuration
• 1 GB DDR3 SDRAM
(1 x 1 GB), single channel
• 2 GB DDR3 SDRAM
(2 x 1 GB), dual channel
• 4 GB DDR3 SDRAM
(2 x 2 GB), dual channel
• 8 GB DDR3 SDRAM 3)
(2 x 4 GB), dual channel
• 16 GB DDR3 SDRAM 3)
(4 x 4 GB), dual channel
• 32 GB DDR3 SDRAM 3)
(4 x 8 GB), dual channel
Removable media
• DVD-ROM
• DVD±RW
Expansions (hardware)
• Without expansions (HW);
onboard graphics
• No expansions (HW); onboard
graphics; DVI-I VGA-compliant
adapter cable for onboard
graphics
• Serial (COM2) & parallel (LPT);
onboard graphics
• Serial (COM2) and parallel (LPT);
onboard graphics; DVI-I VGAcompliant adapter cable for onboard graphics
• Serial (COM2) & parallel (LPT)
+ PCIe x16 graphics card (Dual
Head: 2 x VGA or 2 x DVI-D),
512 MB
A
C
Operating systems
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP3
• Windows 7 Ultimate, MUI
(Eng, Ger, Fr, It, Sp), 32 bit,
SP1 enclosed
• Windows 7 Ultimate, MUI
(Eng, Ger, Fr, It, Sp), 64 bit,
SP1 enclosed
• Windows Server 2008 Standard
Edition incl. 5 Client, MUI
(Eng, Ger, Fr, It, Sp), 32 bit, SP2
• Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 64 bit,
SP1 enclosed
• Without operating system
D
A
B
D
E
G
H
P
Expansions (software)
• SIMATIC IPC DiagMonitor V4.3
software included
• SIMATIC IPC Image & Partition
Creator V3.2 software included
• SIMATIC IPC DiagMonitor V4.3 +
Image & Partition Creator V3.2
software included
• Without expansions (software)
R
S
T
0
1
2
3
4
5
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
2)
Not in combination with redundant power supply
3)
Can only be used on 64-bit operating systems
5/10
Siemens ST 80 / ST PC · 2013
SIMATIC IPC547D
(continued)
1)
Power supply, with country-specific
cable:
• 100/240 V AC industrial power
supply; power cable for Europe
• 100/240 V AC industrial power
supply; USA power cable
• 100/240 V AC industrial power
supply; power cable for China
• 2 x 100/240 V AC redundant industrial power supply; without power
cable
6AG4104- 2 7 7 7 7 - 7 7 7 7
1
2
0
1
2
3
4
B
E
F
P
Q
X
A
B
C
X
0
4
5
6
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
■ Ordering data
Order No.
Preferred variants (ex-stock)
SIMATIC IPC547D
• Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT); 500 GB HDD
SATA internal; 1 GB DDR3 SDRAM
(1 x 1 GB), single channel;
DVD-ROM; interfaces:
2 x Gbit Ethernet (RJ45),
1 x serial, 8 x USB rear,
2 x USB front, 1 x USB internal,
2 x PS/2, audio;
100/240 V industrial power supply,
power cable for Europe;
without operating system
• Core i5-2400 (4C/4T, 3.10 GHz,
6 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT);
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame,
for hot swapping, at the front;
4 GB DDR3 SDRAM (2 x 2 GB)
dual channel; DVD±RW;
interfaces: 2 x Gbit Ethernet
(RJ45), 2 x serial, 1 x parallel,
8 x USB rear, 2 x USB front,
1 x USB internal, 2 x PS/2, Audio;
100/240V industrial power supply,
power cable for Europe;
without operating system
• Core i7-2600 (4C/8T, 3.40 GHz,
8 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT);
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame,
for hot swapping, at the front;
8 GB DDR3 SDRAM (2 x 4 GB)
dual channel; DVD±RW;
interfaces: 2 x Gbit Ethernet
(RJ45), 2 x serial, 1 x parallel,
8 x USB rear, 2 x USB front,
1 x USB internal, 2 x PS/2, audio;
100/240 V industrial power supply,
power cable for Europe, Windows
7 Ultimate MUI (Eng, Ger, Fr, It,
Sp), 64-bit, SP1 supplied
Order No.
Accessories
6AG4104-2AA01-0XX0
6AG4104-2CP22-2XX0
6AG4104-2DP32-2FX0
Memory expansion
• 1 GB DDR3 1333 SDRAM, DIMM
(1 x 1 GB)
• 2 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 1 GB)
• 4 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 2 GB)
• 8 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 4 GB)
6ES7648-2AJ40-0LA0
6ES7648-2AJ50-0LB0
6ES7648-2AJ60-0LB0
6ES7648-2AJ70-0LB0
Tower Kit
For converting the computer into an
industrial tower PC
6ES7648-1AA00-0XC0
Retainer
for pin assignment of the internal
USB port
6ES7648-1AA00-0XK0
Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China
6ES7900-0AA00-0XA0
6ES7900-0BA00-0XA0
6ES7900-0CA00-0XA0
6ES7900-0DA00-0XA0
6ES7900-0EA00-0XA0
6ES7900-0FA00-0XA0
Rack unit for low-profile
HDD swap frame
for 3.5" hard disk, SATA
(without hard disk)
6ES7648-0EG00-1BA0
Expansion components
From page 5/153
5
Note:
Software Packages with SIMATIC WinCC flexible,
SIMATIC WinCC RT Advanced, SIMATIC WinCC, and
SIMATIC WinAC RTX (F) can be ordered together with the
SIMATIC IPC at favorable prices.
More information under
"Embedded Bundles / Packages for industrial PCs".
Siemens ST 80 / ST PC · 2013
5/11
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
■ Dimensional drawings
■ More information
All dimensions in mm. For mounting cut-out see technical
specifications.
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
101.6
37.5
465.1
176.5
481.4
G_ST80_XX_00452
489
18.5
14.3
445.5
433.5
Technical data of the telescopic rails
5
Carrying capacity per pair, min.
30 kg
Full extension length, min.
470 mm
Rail thickness, max.
9.7 mm
Fixing screws
M5 x 6 mm
The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.
The enclosure is prepared for the following telescopic rails:
• Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet
• Schroff: Type 20110-072
5/12
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
■ Overview
■ Technical specifications
SIMATIC IPC647C
General features
Design
19" rack, 2 HUs, external coating
Processor
• Intel Core i7-610E
(2C/4T, 2.53 GHz, 4 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
• Intel Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
• Intel Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache,
EM64T)
Chipset
Intel QM57
Main memory
•
•
•
•
Spare slots for expansions (all long)
• 2 x PCI
• 1 x PCI Express x16
The SIMATIC IPC647C is a very rugged, high-performance
industrial PC in 19" rack design (2 HMs) with excellent industrial
functionality.
It offers:
• Extreme compactness
• Extreme ruggedness
• Intel Core i technology
from 1 GB DDR3 1066 SDRAM
Dual channel support
2 DIMM slots
Expandable up to 8 GB,
optional ECC 1)
or
• 1 x PCI
• 1 x PCI Express x8 (4 lane)
• 1 x PCI Express x16
Graphics
1)
• Onboard Intel GMA HD graphics
controller integrated into processor; dynamic video memory; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 16-bit colors
• PCI Express graphics card
(Dual Head: 2 x VGA or 2 x DVI-D
via display port adapter) in the
PCIe x16 slot; 256 MB; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 32-bit colors
(optional)
Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.
Siemens ST 80 / ST PC · 2013
5/13
5
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
■ Technical specifications (continued)
SIMATIC IPC647C
Operating system
• without
• Preinstalled, activated,
and supplied on restore DVD
• Windows XP Professional MUI,
32-bit
• Windows 7 Ultimate MUI,
32/64-bit
• Windows Server 2003 R2
incl. 5 client MUI, 32-bit
• Windows Server 2008
incl. 5 client MUI, 32-bit
• Windows Server 2008 R2 incl.
5 client MUI, 64-bit
MUI: Multi-language User Interface;
5 languages (English, French,
German, Italian, Spanish)
• Project-specific on request 2)
• Other
• 100 ... 240 V AC, 50 ... 60 Hz;
with bridging of temporary power
failures in accordance with
NAMUR: max. 20 ms at
0.85% rated voltage
• Redundant 100 ... 240 V AC,
50 ... 60 Hz
Power supply
SIMATIC IPC647C
Interfaces
PROFINET
3 x RJ45 (CP 1616-compatible),
optional
PROFIBUS/MPI
12 Mbit/s (isolated, compatible with
CP 5611), optional
Ethernet
2 x 10/100/1000 Mbit/s
(RJ45, teaming-capable)
USB 2.0
• 2 x front (high current)
• 4 x rear (high current)
• 1 x internal (high current), e.g.
for USB dongle with optional lock
Serial
• 9-pin COM1 (V.24)
• 9-pin COM2 (V.24)
Parallel
LPT1
VGA
1x
Keyboard
PS/2
Mouse
PS/2
Audio
1 x Line Out; 1 x Micro
Drives
Hard disks: SATA 3.5" or SAS 3.5"
Mounted in internal shock/
vibration-resistant drive cage
• 250 GB
• 500 GB
• 2 x 500 GB
• 500 GB RAID1 3),
(2 x 500 GB, mirror disks)
Mounted in front drive cage
in swap frame (low profile)
• 250 GB
• 500 GB
• 2 x 500 GB
• 500 GB RAID1 3),
(2 x 500 GB, mirror disks),
"hot swap"
• 1 TB RAID1,
(2 x 1 TB HDD SAS, mirror disks),
"hot swap"; RAID controller in
PCIe x8 slot with zero-maintenance cache protection module
5
Solid-State Drive (SSD) (2.5" SATA)
Installed internally or front-mounted
in removable frame
• 50 GB (SLC), optional
DVD+/-R/RW, slimline
• 8 x 8 x 6 x (DVD media)
• 24 x 24 x 24 x (CD media)
Slots for drives
Front:
• 2 x low profile swap frames
(for 3.5" HDD)
• 1 x 12.7 mm slimline
(for ODD or CF drive)
Internal:
• 2 x 3.5" as an alternative to swap
frames (in the optional, shock and
vibration-damped drive cage)
5/14
Siemens ST 80 / ST PC · 2013
2)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
(LINUX is a trademark of Linus Torvald).
3)
SATA RAID controller on board in Intel chipset
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
■ Technical specifications (continued)
SIMATIC IPC647C
Monitoring functions
SIMATIC IPC647C
Ambient conditions
Basic functionality
Message locally via DiagBas
e software
Degree of protection
IP41 at the front, IP20 at the rear
acc. to EN 60529
Temperature
• Overshoot/undershoot of permissible operating temperature range
• Messages can be evaluated by
the application program
Dust protection
with front door closed: G2 EN 779,
99% of particles > 0.5 mm are held
back
Protection class
Fan
• Speed monitoring
• 2 x enclosure fan (front)
• 1 x power supply fan
Protection class I in accordance
with IEC 61140
Vibration load during operation
DIN EN 60068-2-6, 10 cycles
Watchdog
Monitoring functions via the network
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
SIMATIC IPC DiagMonitor (optional)
Version 4.3 and higher
Remote monitoring capability for:
• Watchdog
• Temperature
• Fan speed
• Hard disk monitoring (SMART)
• Redundant power supply
(module)
• System/Ethernet monitoring
(Heartbeat)
Communication:
• Ethernet interface
(SNMP protocol)
• OPC for integration in
SIMATIC software
• Configuration of
client/server architectures
• Structure of log files
Front LEDs
Internal mounting of the hard disk
drives in optional, internal drive
cage:
• 10 ... 58 Hz: 0.0375 mm;
• 58 ... 500 Hz: 5 m/s2
(approx. 0.5 g)
• Monitoring of program execution
• Monitoring time can be parameterized in software
• Restart can be parameterized in
the event of a fault
• Messages can be evaluated by
the application program
• POWER (internal power supply
unit, PC switched on)
• HARDDISK (access to hard disk)
• ETHERNET1
(Ethernet status, "Heartbeat")
• ETHERNET2
(Ethernet status, "Heartbeat")
• PROFIBUS/MPI
(PROFIBUS status)
• SF PROFINET (PROFINET status)
• WATCHDOG
(ready/fault indication)
• TEMP (temperature status)
• FAN (fan speed monitoring)
• HDD1 ALARM (hard disk alarm
in conjunction with RAID1 and
monitoring software)
• HDD2 ALARM (hard disk alarm
in conjunction with RAID1 and
monitoring software)
Shock loading during operation
DIN EN 60068-2-27,
IEC 60068-2-29
Internal mounting of the hard disk
drives in optional, internal drive
cage:
• Half-sine: 50 m/s2, 30 ms
(ca. 5 g), 100 shocks per axis
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Electromagnetic compatibility (EMC)
Emitted interference (AC)
EN 61000-6-3, EN 61000-3-3,
EN 61000-3-2 Class D;
FCC Class A
Immunity to conducted interference on
the supply lines
± 2 kV (IEC 61000-4-4, burst)
± 1 kV
(IEC 61000-4-5, symm. surge)
± 2 kV
(IEC 61000-4-5, asymm. surge)
Immunity to interference on signal lines
± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
± 2 kV (IEC 61000-4-4, symm.
surge, length > 30 m)
± 2 kV (IEC 61000-4-5, asymm.
surge, length > 30 m)
Siemens ST 80 / ST PC · 2013
5/15
5
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
■ Technical specifications (continued)
SIMATIC IPC647C
Immunity to static discharge
±6 kV, contact discharge
(IEC 61000-4-2)
±8 kV, air discharge
(IEC 61000-4-2)
Immunity to high radio frequency
interference
• 1 V/m 80% AM 1 kHz;
2 ... 2.7 GHz (IEC 61000-4-3)
• 10 V/m 80% AM 1 kHz;
80 MHz - 1 GHz and
1.4 GHz - 2 GHz (IEC 61000-4-3);
• 10 V, 10 kHz to 80 MHz
(IEC 61000-4-6)
Immunity to magnetic fields
100 A/m, 50/60 Hz (IEC 61000-4-8)
Ambient temperature during operation
5 … 50 °C
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Relative operating humidity
5 ... 85 % at 30 °C
(no condensation)
Approvals and safety regulations
Safety regulations
IEC 60950-1 Second Edition,
EN 60950-1, UL 60950,
CSA C22.2 No 60950
Approvals
cULus 60950, KCC
Marine approval
(only for configurations with
CompactFlash or SSD memory)
•
•
•
•
CE mark
Use in industry:
• Noise immunity:
EN 61000-6-2:2005
5
GL –- Germanische Lloyd
BV – Bureau Veritas
LR – Lloyds Register of Shipping
ABS – American Bureau of
Shipping
• DNV – Det Norske Veritas
• NKK – Nippon Kaiji Kyokai
Use in domestic environments:
• Emitted interference:
EN 61000-6-3:2007
Dimensions and weights
Mounting dimensions
(W x H x D, in mm)
430 x 88 x 445
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations.
5/16
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
■ Ordering data
SIMATIC IPC647C
Order No.
1)
Order No.
6AG4112- 1 7 7 7 7 - 7 7 7 7
Interfaces:
2 x 10/100/1000 Mbps Ethernet
(RJ45); 1 x graphic (DVI-I);
2 x COM; 1 x LPT; 2 x PS/2;
4 x USB 2.0 at rear, 2 x USB 2.0
at front; 1 x USB 2.0 internal; audio;
temperature and fan monitoring,
watchdog; card retainer
Processor/motherboard
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard without fieldbus
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard with PROFIBUS/MPI
• Core i3-330E
(2C/4T; 2.13 GHz, 3 MB cache),
motherboard with PROFINET
(3 x RJ45, CP 1616-compatible) 2)
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
without fieldbus
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard with
PROFIBUS/MPI
• Core i5-520E
(2C/4T; 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard with
PROFINET (3 x RJ45,
CP 1616-compatible) 2)
• Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard without field bus
• Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard with PROFIBUS/MPI
• Core i7-610E
(2C/4T; 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard with
PROFINET (3 x RJ45,
CP 1616-compatible) 2)
Hard disks:
• 250 GB HDD SATA; 0.5 g vibration,
5 g shock, internal
• 500 GB HDD SATA; 0.5 g vibration,
5 g shock, internal
• 2 x 500 GB HDD SATA; 0.5 g vibration, 5 g shock, internal
• RAID1 500 GB (2 x 250 GB HDD
SATA, mirror disks); 0.5 g vibration,
5 g shock, internal
• 250 GB HDD SATA in swap frame;
front
• 500 GB HDD SATA in swap frame;
front
• 2 x 500 GB HDD SATA in swap
frame; front
• RAID1 500 GB (2 x 250 GB HDD
SATA) in swap frame, for hot swapping; front
• 50 GB SSD (SLC) SATA, internal
• 50 GB SSD (SLC) SATA in swap
frame; front
• RAID1 1 TB (2 x 1 TB HDD SAS) in
swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protection module in PCIe x16 slot 3)
SIMATIC IPC647C
(continued)
1)
6AG4112- 1 7 7 7 7 - 7 7 7 7
Memory configuration:
• 1 GB DDR3 SDRAM (1 x 1 GB),
single channel
• 2 GB DDR3 SDRAM (1 x 2 GB),
single channel
• 4 GB DDR3 SDRAM (2 x 2 GB),
dual channel
• 6 GB DDR3 SDRAM
(1 x 2 GB, 1 x 4 GB), dual channel
• 8 GB DDR3 SDRAM (2 x 4 GB),
dual channel
• 2 GB DDR3 SDRAM (2 x 1 GB),
dual channel
• 4 GB DDR3 SDRAM (2 x 2 GB),
dual channel
• 8 GB DDR3 SDRAM (2 x 4 GB),
dual channel
G
H
J
Swap media:
• CompactFlash drive, at front
• DVD±RW
• without swap medium
K
L
M
N
P
R
A
B
C
D
H
0
1
2
3
4
5
6
7
0
1
8
Bus module / hardware expansion
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16; without hardware
expansions
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16; DVI-VGA adapter
(1 x VGA) for onboard graphics
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16 assigned; + graphics
card PCIe x16, 2 x DP (2 x DVI-D
via 2 x DP-DVI adapters)
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16 assigned; + graphics
card PCIe x16, 2 x DP (2 x VGA via
2 x DP-VGA adapters)
• Bus modules 3 slots: 1 x PCI,
1 x PCIe x8 (4-lane); 1 x PCIe x16;
without HW expansions
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16;
DVI-VGA adapter (1 x VGA) for onboard graphics
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16
assigned; + graphics card
PCIe x16, 2 x DP (2x DVI-D via
2x DP-DVI adapters)
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16
assigned; + graphics card
PCIe x16, 2 x DP (2x VGA via
2x DP-VGA adapters)
0
1
2
3
5
4
5
6
7
K
M
P
S
T
U
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
2)
Not in combination with Windows Server operating systems.
3)
Not in combination with graphics card, Windows XP, Windows 7 (32-bit),
without removable media.
Siemens ST 80 / ST PC · 2013
5/17
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
■ Ordering data
SIMATIC IPC647C 1)
(continued)
Order No.
Operating system
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), SP3, 32-bit
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included
• Windows Server 2003 R2 Standard
Edition incl. 5 clients, MUI (Eng, Fr,
Ger, It, Sp), SP2, 32-bit, SP2
• Windows Server 2008 Standard
Edition incl. 5 clients, MUI
(Eng, Fr, Ger, It, Sp), SP2, 32-bit
• Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI (Eng, Fr,
Ger, It, Sp), SP2, 64-bit, SP1 included
• Without operating system
Expansion (software)
• SIMATIC IPC DiagMonitor 4.3
included
• SIMATIC IPC Image Creator
software 3.2 included
• SIMATIC IPC DiagMonitor 4.3
and Image Creator Software 3.2
included
• Without software
5
Order No.
6AG4112- 1 7 7 7 7 - 7 7 7 7
Memory expansion
• 1 GB DDR3 1066 SDRAM, DIMM
• 2 GB DDR3 1066 SDRAM, DIMM
• 4 GB DDR3 1066 SDRAM, DIMM
• 1 GB DDR3 1066 SDRAM, DIMM,
ECC
• 2 GB DDR3 1066 SDRAM, DIMM,
ECC
• 4 GB DDR3 1066 SDRAM, DIMM,
ECC
B
E
F
N
P
Q
X
B
C
X
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
0
1
2
6ES7648-2AJ40-0KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-1KA0
Hard disk slide-in unit
for swap frame
SIMATIC PC accessories, slide-in
HDD swap frame, low-profile, for
3.5" hard disk, serial ATA / SAS
(without hard disk)
6ES7648-0EG00-1BA0
Filter mats
for SIMATIC IPC647C
(packing unit: 10 units)
A5E02396171
Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China
A
Power supply, with country-specific
cable:
• 100/240°V°AC industrial power
supply with Namur; power cable
for Europe
• 100/240 V AC industrial power
supply with Namur; power cable
for United Kingdom
• 100/240 V AC industrial power
supply with Namur; power cable
for Switzerland
• 100/240 V AC industrial power
supply with Namur; power cable
for USA
• 100/240 V AC industrial power
supply with Namur; power cable
for Italy
• 100/240 V AC industrial power
supply with Namur; power cable
for China
• 100/240 V AC redundant power
supply with Namur; without power
cable
1)
Accessories
6ES7900-0AA00-0XA0
6ES7900-0BA00-0XA0
6ES7900-0CA00-0XA0
6ES7900-0DA00-0XA0
6ES7900-0EA00-0XA0
6ES7900-0FA00-0XA0
USB retainer
for pin assignment of the internal
USB port
6ES7648-1AA00-0XK0
Expansion components
From page 5/153
Communication products
From page 5/186
RMOS real-time operating system
From page 5/146
3
4
5
6
Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded bundles / Packages for
industrial PCs".
5/18
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
■ Dimensional drawings
■ More information
All dimensions in mm. For mounting cut-out see technical specifications.
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
481.4
87.6
5.7
76.2
465
G_ST80_XX_00453
444.6
429.9
487.1
8.2
Technical data of the telescopic rails
Carrying capacity per pair, min.
30 kg
Full extension length, min.
470 mm
Rail thickness, max.
9.7 mm
Fixing screws
M5 x 6 mm
5
The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.
The enclosure is prepared for the following telescopic rails:
• Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet
Siemens ST 80 / ST PC · 2013
5/19
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
■ Overview
■ Technical specifications
SIMATIC IPC847C
General features
Design
19" rack, 4 HU, externally painted
Processor
• Intel Core i7-610E
( 2C/4T, 2.53 GHz, 4 MB Cache,
Turbo Boost, VT-d, iAMT, EM64T)
• Intel Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
• Intel Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache,
EM64T)
Chipset
Intel QM57
Main memory
•
•
•
•
Spare slots for expansions (all long)
• 7 x PCI
• 1 x PCI Express x16
• 3 x PCI Express x4
The SIMATIC IPC847C is a very robust, high-performance industrial PC in 19" rack design (4 HU) with excellent industrial
functionality.
It offers:
• Maximum expandability
• Extreme ruggedness
• Intel Core i technology
or
• 7 x PCI
• 1 x PCI Express x16
Graphics
1)
5
5/20
Siemens ST 80 / ST PC · 2013
from 1 GB DDR3 1066 SDRAM
Dual channel support
2 DIMM slots
Expandable up to 8 GB 1)
• Onboard Intel GMA HD graphics
controller integrated into processor; dynamic video memory; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 16-bit colors
• PCI Express graphics card
(Dual Head: 2 x VGA or 2 x DVI-D
via display port adapter) in the
PCIe x16 slot; 256 MB; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 32-bit colors
(optional)
Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
■ Technical specifications (continued)
SIMATIC IPC847C
Operating system
• without
• Preinstalled and activated /
supplied on restore DVD
• Windows XP Professional MUI,
32-bit
• Windows 7 Ultimate MUI,
32/64-bit
• Windows Server 2003 R2
incl. 5 client MUI, 32-bit
• Windows Server 2008 incl.
5 client MUI, 32-bit
• Windows Server 2008 R2
incl. 5 client MUI, 64-bit
MUI: Multi-language User Interface;
5 languages (English, French,
German, Italian, Spanish)
• Project-specific on request
• Linux 2)
• Other
Power supply
• 100 ... 240 V AC, 50 ... 60 Hz
with bridging of temporary power
failures in accordance with
NAMUR: max. 20 ms at
0.85% rated voltage
• Redundant 100 ... 240 V AC,
50 ... 60 Hz
SIMATIC IPC847C
Interfaces
PROFINET
3x RJ45 (CP 1616-compatible),
optional
PROFIBUS/MPI
12 Mbit/s (isolated, compatible
with CP 5611), optional
Ethernet
2 x 10/100/1000 Mbit/s
(RJ45, teaming-capable)
USB 2.0
• 2 x front (high current)
• 4 x rear (high current)
• 1 x internal (high current),
e.g. for USB dongle
Serial
• 9-pin COM1 (V.24)
• 9-pin COM2 (V.24)
Parallel
LPT1
VGA
1x
Keyboard
PS/2
Mouse
PS/2
Audio
1 x Line Out; 1 x Micro
Drives
Hard disks SATA 3.5" or SAS 3.5"
Installation in internal drive cage
• 250 GB
Can be installed in internal shock
and vibration-damped drive cage
(optional)
• 250 GB
• 500 GB
• 2 x 500 GB
• 500 GB RAID13),
(2 x 500 GB, mirror disks)
Installation in front drive cage in
swap frame
• 250 GB
• 2 x 500 GB
• 500 GB RAID13),
(2 x 500 GB, mirror disks),
"hot swap"
• 1 TB RAID53), (3 x 500 GB,
striping with parity), "hot swap"
• 1 TB RAID1, (2 x 1 TB, mirror
disks), "hot swap"; PCIe x8 RAID
controller in PCIe x16 slot
• 1.8 TB RAID5, (3 x 1 TB, striping
with parity), "hot swap"; controller
with zero-maintenance cache protection module in PCIe x16 slot
• 50 GB SATA solid-state drive
(SLC)
Solid-State Drive (SSD) (2.5" SATA)
Installed internally or front-mounted
in removable frame
50 GB (SLC), optional
DVD-ROM, 5.25", SATA
• 16 x (DVD media)
• 48 x (CD media)
DVD+/-R/RW, 5.25", SATA
• 16 x 16 x 12 x (DVD media)
• 48 x 32 x 48 x (CD media)
Floppy disk
-
Slots for drives
Front:
• 3 x 5.25" and 2 x 3.5"
5
Internal:
• 2 x 3.5" (in the optional,
vibration-damping drive cage)
2)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
3)
SATA RAID controller on board in Intel chipset
Siemens ST 80 / ST PC · 2013
5/21
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
■ Technical specifications (continued)
SIMATIC IPC847C
Monitoring functions
SIMATIC IPC847C
Ambient conditions
Basic functionality
Message locally
via DiagBase software
Degree of protection
IP41 at the front, IP20 at the rear
acc. to EN 60529
Temperature
• Overshoot/undershoot of permissible operating temperature range
• Messages can be evaluated by
the application program
Dust protection
With front door closed: G2 EN 779,
99% of particles > 0.5 mm are held
back
Protection class
Fan
• Speed monitoring
• 2 x enclosure fans
• 1 x fan power supply
Protection class I in accordance
with IEC 61140
Vibration load during operation
DIN EN 60068-2-6, 10 cycles
Watchdog
• Monitoring of program execution
• Monitoring time can be parameterized in software
• Restart can be parameterized in
the event of a fault
• Messages can be evaluated by
the application program
Monitoring functions via the network
SIMATIC PC DiagMonitor (optional)
Internal mounting of the hard disk
drives in optional, internal drive
cage:
• 10 ... 58 Hz: 0.0375 mm
• 58 ... 500 Hz: 5 m/s2
(approx. 0.5 g)
Permanently installed internal hard
disk drives:
• 10 ... 58 Hz: 0.019 mm
• 58 ... 500 Hz: 3 m/s2
(approx. 0.3 g)
Remote monitoring capability for:
• Watchdog
• Temperature
• Fan speed
• Hard disk monitoring (SMART)
• System/Ethernet monitoring
(Heart Beat)
Communication:
• Ethernet interface
(SNMP protocol)
• OPC for integration
in SIMATIC software
• Configuration of
client/server architectures
• Structure of log files
Front LEDs
5
5/22
• POWER (internal power supply
unit, PC switched on)
• HARDDISK (access to hard disk)
• ETHERNET1
(Ethernet status, "Heartbeat")
• ETHERNET2 (Ethernet status,
"Heartbeat")
• PN / MPI/DP
(PROFINET/PROFIBUS status)
• WATCHDOG
(ready/fault indication)
• TEMP (temperature status)
• FAN (fan speed monitoring)
• HDD1 ALARM (hard disk alarm in
conjunction with RAID and monitoring software)
• HDD2 ALARM (hard disk alarm in
conjunction with RAID and monitoring software)
• HDD3 ALARM (hard disk alarm in
conjunction with RAID and monitoring software)
Siemens ST 80 / ST PC · 2013
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Shock loading during operation
DIN EN 60068-2-27,
IEC 60068-2-29
Internal mounting of the hard disk
drives in optional, internal drive
cage:
• Half-sine: 50 m/s2, 30 ms
(approx. 5 g), 100 shocks
per axis
• Permanently installed internal
hard disk drives: 30 m/s2,
30 ms (approx. 3 g)
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
■ Technical specifications (continued)
SIMATIC IPC847C
Electromagnetic compatibility (EMC)
Emitted interference (AC)
EN 61000-6-3 FCC Class A
EN 61000-3-2 Class D and
EN 61000-3-3
Immunity to conducted interference
on the supply lines
± 2 kV (IEC 61000-4-4, burst)
± 1 kV
(IEC 61000-4-5, symm. surge)
± 2 kV
(IEC 61000-4-5, asymm. surge)
Immunity to interference on signal lines
± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
± 2 kV (IEC 61000-4-4, symm.
surge, length > 30 m)
± 2 kV (IEC 61000-4-5, asymm.
surge, length > 30 m)
Immunity to static discharge
±6 kV, contact discharge
(IEC 61000-4-2)
±8 kV, air discharge
(IEC 61000-4-2)
Immunity to high radio frequency
interference
• 1 V/m 80% AM; 2-2.7 GHz
(IEC 61000-4-3)
• 10 V/m 80% AM; 80 MHz to
1 GHz and 1.4 GHz and 2 GHz
(IEC 61000-4-3);
• 10 V, 10 kHz to 80 MHz
(IEC 61000-4-6)
Immunity to magnetic fields
100 A/m, 50/60 Hz (IEC 61000-4-8)
Ambient temperature
during operation
5 ... 50 °C
Relative operating humidity
5 ... 80% at 25 °C
(no condensation)
Note:
There are limitations when using
DVD-ROM / DVD+/-RW and SAS
HDD in swap frames
5
Approvals and safety regulations
Safety regulations
IEC 60950-1 Second Edition,
EN 60950-1:2006,
UL 60950-1 Second Edition
CSA C22.2 No 60950-1-07
Second Edition
Approvals
cULus 60950-1 Second Edition,
KCC
CE mark
• Emitted interference:
EN 61000-6-3:2007
• Noise immunity:
EN 61000-6-2:2005
Dimensions and weights
Mounting dimensions
(W x H x D, in mm)
430 x 177 x 448
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations.
Siemens ST 80 / ST PC · 2013
5/23
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
■ Ordering data
SIMATIC IPC847C
Order No.
1)
Order No.
6AG4114- 1 7 7 7 7 - 7 7 7 7
Interfaces: 2 x 10/100/1000 Mbps
Ethernet (RJ45);
1 x graphic (DVI-I); 2 x COM;
1 x LPT; 2 x PS/2;
4 x USB 2.0 at rear,
2 x USB 2.0 at front,
1x USB 2.0 internal; audio;
temperature and fan monitoring,
watchdog;
5
Processor, motherboard:
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard without fieldbus
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard with PROFIBUS/MPI
• Core i3-330E
(2C/4T; 2.13 GHz, 3 MB cache),
motherboard with PROFINET
(3 x RJ45, CP 1616-compatible) 2)
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
without fieldbus
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
with PROFIBUS/MPI
• Core i5-520E
(2C/4T; 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
with PROFINET (3 x RJ45,
CP 1616-compatible) 2)
• Core i7-610E
(2C/4T, 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard
without field bus
• Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard with PROFIBUS/MPI
• Core i7-610E
(2C/4T; 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard
with PROFINET (3 x RJ45,
CP 1616-compatible) 2)
5/24
Siemens ST 80 / ST PC · 2013
G
H
J
K
L
M
N
P
R
SIMATIC IPC847C
(continued)
1)
Hard disks:
• 250 GB HDD SATA; 0.5 g vibration,
5 g shock, internal
• 500 GB HDD SATA; 0.5 g vibration,
5 g shock, internal
• 2 x 500 GB HDD SATA; 0.5 g vibration, 5 g shock, internal
• RAID1 500 GB (2 x 500 GB HDD
SATA, mirror disks); 0.5 g vibration,
5 g shock, internal
• 250 GB HDD SATA; 0.3 g vibration,
3 g shock, internal
• 250 GB HDD SATA in swap frame;
front
• 500 GB HDD SATA in swap frame;
front
• 2 x 500 GB HDD SATA in swap
frame; front
• RAID1 500 GB
(2 x 500 GB HDD SATA) in swap
frame, for hot swapping; front
• RAID5 1 TB
(3 x 500 GB HDD SATA) in swap
frame, for hot swapping; front
• 50 GB SSD (SLC) SATA, internal
• 50 GB SSD (SLC) SATA in swap
frame; front
• RAID1 1 TB (2 x 1 TB HDD SAS)
in swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protection module in PCIe x16 slot 3)
• RAID5 1.8 TB (3 x 1 TB HDD SAS)
in swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protection module in PCIe x16 slot 3)
Memory configuration:
• 1 GB DDR3 SDRAM
(1 x 1 GB), single channel
• 2 GB DDR3 SDRAM
(1 x 2 GB), single channel
• 4 GB DDR3 SDRAM
(2 x 2 GB), dual channel
• 6 GB DDR3 SDRAM
(1 x 2 GB, 1 x 4 GB), dual channel
• 8 GB DDR3 SDRAM
(2 x 4 GB), dual channel
• 2 GB DDR3 SDRAM
(2 x 1 GB), dual channel
• 4 GB DDR3 SDRAM
(2 x 2 GB), dual channel
• 8 GB DDR3 SDRAM
(2 x 4 GB), dual channel
6AG4114- 1 7 7 7 7 - 7 7 7 7
A
B
C
D
G
H
K
M
P
R
S
T
U
V
0
1
2
3
4
5
6
7
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
2)
Not in combination with Windows Server 2008 R2, Windows Server 2008
and Windows Server 2003 R2
3)
Not in combination with graphics card, Windows XP, Windows 7 (32-bit),
without removable media.
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
■ Ordering data
SIMATIC IPC847C 1)
(continued)
Swap media:
• DVD-ROM
• DVD+/-RW
• Without swap medium
Bus module / hardware expansion
• Bus module, 8 slots:
7 x PCI, 1 x PCIe x16;
without hardware expansions
• Bus module, 8 slots:
7 x PCI; 1x PCIe x16;
DVI-VGA adapter (1 x VGA)
for onboard graphics
• Bus module, 8 slots:
7x PCI; 1x PCIe x16 assigned;
+ graphics card PCIe x16, 2 x DP
(2x DVI-D via 2x DP-DVI adapters)
• Bus module, 8 slots:
7x PCI; 1x PCIe x16 assigned;
+ graphics card PCIe x16, 2 x DP
(2x VGA via 2x DP-VGA adapters)
• Bus module, 11 slots:
7 x PCI, 1 x PCIe x16, 3 x PCIe x4;
without hardware expansions
• Bus module, 11 slots:
7x PCI, 1x PCIe x16, 3x PCIe x4;
+ DVI-VGA adapter (VGA) for
onboard graphics
• Bus module, 11 slots:
7x PCI; 1x PCIe x16 assigned,
3x PCIe x4; + graphics card
PCIe x16, 2 x DP (2x DVI-D via
2x DP-DVI adapters)
• Bus module, 11 slots:
7x PCI; 1x PCIe x16 assigned;
3x PCIe x4; + graphics card
PCIe x16, 2x DP (2x VGA via
2x DP-VGA adapters)
Order No.
Order No.
6AG4114- 1 7 7 7 7 - 7 7 7 7
1
2
8
0
1
2
3
4
5
6
7
SIMATIC IPC847C 1)
(continued)
6AG4114- 1 7 7 7 7 - 7 7 7 7
Operating system
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP3
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included
• Windows Server 2003 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Fr, Ger, It, Sp), 32-bit, SP2
• Windows Server 2008 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP2
• Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 64-bit, SP1
enclosed
• Without operating system
Software expansion
• SIMATIC IPC DiagMonitor 4.3
included
• SIMATIC IPC Image Creator
software 3.2 included
• SIMATIC IPC DiagMonitor 4.3 &
Image Creator software 3.2
included
• Without software
Power supply,
country-specific cable
• 100/240 V AC industrial power
supply with Namur; power cable
for Europe
• 100/240 V AC industrial power
supply with Namur; power cable
for United Kingdom
• 100/240 V AC industrial power
supply with Namur; power cable
for Switzerland
• 100/240 V AC industrial power
supply with Namur; power cable
for USA
• 100/240 V AC industrial power
supply with Namur; power cable
for Italy
• 100/240 V AC industrial power
supply with Namur; power cable
for China
• 100/240 V AC industrial redundant
power supply unit with Namur;
without power cable
1)
B
E
F
N
P
Q
X
A
B
C
X
0
1
2
3
4
5
6
For an up-to-date overview, see the SIMATIC PC online configurator at:
http://www.siemens.com/ipc-configurator
Siemens ST 80 / ST PC · 2013
5/25
5
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
■ Ordering data
Order No.
Order No.
Accessories
Memory expansion
• 1 GB DDR3 1066 SDRAM, DIMM
• 2 GB DDR3 1066 SDRAM, DIMM
• 4 GB DDR3 1066 SDRAM, DIMM
• 1 GB DDR3 1066 SDRAM, DIMM,
ECC
• 2 GB DDR3 1066 SDRAM, DIMM,
ECC
• 4 GB DDR3 1066 SDRAM, DIMM,
ECC
Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China
6ES7648-2AJ40-0KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-1KA0
Hard disk slide-in unit
for swap frame
SIMATIC PC accessories,
slide-in unit for low-profile HDD
swap frame, for 3.5" hard disk,
SATA / SAS (without hard disk)
6ES7648-0EG00-1BA0
Filter mats
For Rack PC 847B and IPC847C
Packing unit 10 units
A5E01064980
Tower Kit
for converting the computer into an
industrial tower PC
6ES7900-0AA00-0XA0
6ES7900-0BA00-0XA0
6ES7900-0CA00-0XA0
6ES7900-0DA00-0XA0
6ES7900-0EA00-0XA0
6ES7900-0FA00-0XA0
6ES7648-1AA00-0XD0
Retainer
for pin assignment of the internal
USB port
6ES7648-1AA00-0XK0
Expansion components
From page 5/153
Communication products
From page 5/186
RMOS real-time operating system
From page 5/146
Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".
■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
101.6
5
176.5
481.4
465.1
*B67B;;B
492
448
Further information can be found in the Internet under:
Siemens ST 80 / ST PC · 2013
470 mm
Rail thickness, max.
9.7 mm
Fixing screws
M5 x 6 mm
The enclosure is prepared for the following telescopic rails:
• Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet
• Schroff: Type 20110-072
■ More information
5/26
30 kg
Full extension length, min.
The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.
430
http://www.siemens.com/simatic-pc
Technical data of the telescopic rails
Carrying capacity per pair, min.
© Siemens AG 2013
PC-based Automation
Box PC
Box PC
■ Overview
SIMATIC Box PCs provide mechanical engineers, plant
engineers and control cabinet makers with particularly rugged
industrial PC systems for use in powerful yet compact applications.
The following device classes are available for various requirements:
• SIMATIC IPC227 (Nanobox PC):
The compact embedded IPC – maintenance-free and
dust-proof with versatile mounting
• SIMATIC IPC427 (Microbox PC):
The powerful embedded IPC – maintenance-free with
versatile configuration
• SIMATIC IPC627/IPC827 (Box PC):
The high-end IPC – with maximum performance, functional
scope, and expansion capability
Shared industrial functionality:
• Extreme compactness
• Certification for global marketing
• System-tested with SIMATIC components
• High vibration/shock load during operation
• Wide operational temperature range
• Robust data storage with CompactFlash/CFast or Solid-State
Drive (SSD)
• Integrated PROFIBUS or PROFIBUS/MPI interface (optional)
• Varied mounting possibilities for flexibility with installation
• Designed for 24-hour continuous operation
• Integrated parameterizable monitoring functions
(temperature, fan, watchdog)
• High service friendliness
• Operating system preinstalled and activated for fast startup
• Motherboard developed and manufactured by Siemens
• Availability for 3 to 6 years
• Repairs and spare parts service for 5 years
• High continuity of the components/design
• Installation and software compatible with predecessor model
• Long-term availability of PC components from the Intel
embedded line
SIMATIC IPC227 (Nanobox PC):
The compact embedded IPC – maintenance-free and dustproof with versatile mounting
• Maximum compactness with approx. 1 liter enclosure volume
with integrated industrial power supply for minimum space
requirements in the control cabinet
• Maximum flexibility thanks four mounting options and interfaces on one side suitable for every installation situation
• Optimum variety of interfaces due to a large number of
integrated interfaces such as selectable serial ports
(RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN
• Maximum industrial functionality due to closed enclosure for
optimum dust protection and non-volatile retentive memory
• Further device options for optimum adaptation to the
application with additional PCIe slot or RS 232 interfaces
or digital I/O
Siemens ST 80 / ST PC · 2013
5/27
5
© Siemens AG 2013
PC-based Automation
Box PC
Box PC
■ Overview (continued)
SIMATIC IPC427 (Microbox PC):
The powerful embedded IPC – maintenance-free with
versatile configuration
• Fan-free operation
• High performance with maximum compactness and
ruggedness for direct installation in the machine
• Optimized for embedded applications
• Flexibility expandable using one or two PCIe I/O cards
(optional)
• Flexible installation options due to DIN rail/wall/front upright
mounting, even outside a control cabinet
• NVRAM for retentive data storage (optional)
SIMATIC IPC627/IPC827 (Box PC):
The high-end IPC – with maximum performance, functional
scope, and expansion capability
• Maximum system performance for complex measuring,
control and visualization tasks
• High flexibility with expansion slots and integral interfaces
• Flexible, space-saving installation with mounting brackets or
portrait assembly kits
• Rugged design for direct installation in the machine
• RAID1 controller onboard
• Maximum processor performance up to ambient temperature
of 55 °C
• High system availability
• Battery-backed SRAM as memory for WinAC data
• 2 x 7-segment display and 2 signal LEDs
(freely programmable)
SIMATIC IPC227D
(Nanobox PC)
SIMATIC IPC427D
(Microbox PC)
SIMATIC IPC427C
(Microbox PC)
SIMATIC IPC627C
(Box PC)
SIMATIC IPC827C
(Box PC)
Rail or wall mounting
•
•
•
-
-
Wall or portrait mounting
• Also: Side mounting
•
•
•
•
Processor
• Intel Atom E620
600 MHz
• Intel Atom E640
1.0 GHz
• Intel Atom E660
1.3 GHz
• Intel Core i73517UE, 1.7 GHz,
4 MB SLC
• Intel Core i33217UE, 1.6 GHz,
3 MB SLC
• Intel Celeron 827E
1.4 GHz, 1.5 MB
SLC
• Intel Core2 Duo
1.2 GHz, 800 MHz
FSB, 3 MB SLC
• Intel Core2 Solo
1.2 GHz, 800 MHz
FSB, 3 MB SLC
• Intel Celeron M
1.2 GHz, 800 MHz
FSB, 1 MB SLC
• Intel Core i7-620E,
2.53 GHz, 2 cores,
4 threads, 4 MB
cache, TB, HT, VT-x,
VT-d
• Intel Core i3-330E,
2.13 GHz, 2 cores,
4 threads, 3 MB
cache, HT, VT-x
• Intel Celeron P4505,
1.86 GHz, 2 cores,
2 MB cache
• Intel Core i7-620E,
2.53 GHz, 2 cores,
4 threads, TB, HT,
VT-x, VT-d, AMT 4
MB cache
• Intel Core i3-330E,
2.13 GHz, 2 cores,
4 threads, HT, VT-x,
3 MB cache
• Intel Celeron P4505,
1.86 GHz, 2 cores,
2 MB cache
Main memory
512 MB, 1 GB, 2 GB
1 GB, 2 GB, 4 GB,
8 GB
1 GB, 2 GB, 4 GB
1 GB, expandable up
to 8 GB,
optional ECC
1 GB, expandable up
to 8 GB,
optional ECC
Static RAM
512 KB
512 KB
2 MB
2 MB
2 MB
Free slots for expansions
1 x PCIe with PCIe
enclosure option
Up to 2 x PCIe
(enclosure option)
Up to 3 x PCI-104
(with expansion frame)
2 x PCI or
1 x PCI-Express x16 /
1 x PCI
(175 mm / 265 mm)
3 x PCI
(290/290/240 mm),
1 PCI-Express x
(185 mm)
1 x PCI-Express x16
(240 mm)
Graphics
Onboard
Onboard
Onboard
Onboard
Onboard
Design
General features
5
5/28
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Box PC
Box PC
■ Overview (continued)
SIMATIC IPC227D
(Nanobox PC)
SIMATIC IPC427D
(Microbox PC)
SIMATIC IPC427C
(Microbox PC)
SIMATIC IPC627C
(Box PC)
SIMATIC IPC827C
(Box PC)
without
•
•
•
•
•
Preinstalled and activated / supplied
on restore CD
• Windows Embedded Standard 2009
(CF card t 2 GB,
SSD, hard disk)
• Windows XP Professional MUI (SSD,
hard disk)
• Windows Embedded Standard 7,
32 bit
(CF card t 4 GB,
SSD, hard disk)
• Windows 7 Ultimate
MUI, 32 bit (SSD,
hard disk)
• Windows 7
Ultimate MUI
• Windows Embedded Standard 7 in
combination with
CF card t 4 GB,
solid-state drive,
or hard drive
• Windows Embedded
Standard 2009, in
combination with CF
card t 2 GB, solidstate drive, or hard
drive
• Windows XP Professional Multi-Language; in combination
with solid-state drive
or hard drive
• Windows 7 Ultimate
MUI
• Windows Embedded
Standard 7
• Windows XP
Professional MUI
• Windows 7 Ultimate
32-bit MUI
• Windows 7 Ultimate
64-bit MUI
• Windows Embedded Standard 2009
English on 8 GB
CompactFlash
• Windows XP
Professional MUI
• Windows 7 Ultimate
32-bit MUI
• Windows 7 Ultimate
64-bit MUI
• Windows Embedded Standard 2009
English on 8 GB
CompactFlash
Order separately
RMOS3 V3.50
RMOS3 V3.50
RMOS3 V3.50
RMOS3 V3.50
RMOS3 V3.50
Project-specific on request
• Linux 1)
• Other
• Linux 1)
• Other
• Linux 1)
• Other
• Linux 1)
• Other
• Linux 1)
• Other
PROFINET onboard
-
3 x RJ45 (CP 1616
compatible)
onboard, optional
3 x RJ45 (CP 1616
compatible) onboard,
optional
3 x RJ45 (CP 1616
compatible) onboard,
optional
3 x RJ45 (CP 1616
compatible) onboard,
optional
PROFIBUS/MPI
-
12 Mbps (compatible with CP 5622),
optional
12 Mbps (CP 5611compatible), optional
12 Mbps (CP 5611compatible) onboard,
optional
12 Mbps (CP 5611compatible) onboard,
optional
Ethernet
2 x 10/100/
1000 Mbps
2 x 10/100/
1000 Mbps
2 x 10/100/1000 Mbps
2 x 10/100/
1000 Mbps
1 x 10/100/
1000 Mbps
USB 2.0 (high current)
4x
4 x USB 3.0
4x
4x
4x
VGA, LVDS, DVI, DPP
1 x DVI-D
• 1 x DVI-I
(DVI and VGA)
• 1 x DisplayPort
1 x DVI-I
(DVI and VGA)
1 x DVI-I
(DVI and VGA)
1 x DVI-I
(DVI and VGA)
Hard disks
1 x 2.5" (optional)
1 x 2.5" (optional)
1 x 2.5" (optional)
• 1 x 3.5"
• 2 x 2.5"
• RAID1/2 x 2.5"
• 1 x 3.5"
• 2 x 2.5"
• RAID1/2 x 2.5"
Solid-state drive
1 x 2.5" SATA
(optional)
1 x 2.5" SATA
(optional)
1 x 2.5" SATA (optional)
1 x 2.5" SATA
(optional)
1 x 2.5" SATA
(optional)
FlashDrive
1 x CF externally
accessible
• 1 x CFast externally accessible
• 1 x CFast internal,
in place of HDD,
SSD (optional)
• 1 x CF externally
accessible
• 1 x CF internal, in
place of HDD, SSD
(optional)
• 1 x CF at the front,
externally accessible
• 1 x CF internal, in
place of HDD
(optional)
1 x CF at the front,
externally accessible
Optical drives
-
-
-
DVD R/W
DVD R/W
Vibration/shock load during operation
1 g / 15 g
(with FlashDrive)
1 g / 15 g
(with FlashDrive)
1 g / 15 g
(with FlashDrive)
1g/5g
1g/5g
Ambient temperature
during operation
0 °C … 50 °C
(with FlashDrive)
0 °C … 40 °C
(with hard disk)
With maximum
configuration:
0 ... 50/55 ºC
(with FlashDrive)
With maximum
configuration:
0 ... 50/55 ºC
(with FlashDrive)
With maximum
configuration:
5 ... 45 °C
With maximum
configuration:
5 ... 45 °C
5 ... 40 ºC
(with hard disk)
5 ... 40 ºC
(with hard disk)
5 ... 50/55 °C
(with 20/10 W load on
PCI/PCI-Express bus)
5 ... 50/55 °C
(with 20/10 W load on
PCI/PCI-Express bus)
Operating system
Interfaces
Drives
Ambient conditions
• Available
- Not available
1)
Suitable for specific Linux versions in accordance with the specifications of
the Siemens manufacturer's declaration "Suitable for Linux", see
http://www.siemens.com/simatic-pc/suited-for-linux
(Linux is a trademark of Linus Torvald).
■ More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
Information material can be ordered or downloaded from the
Internet:
http://www.siemens.com/simatic/printmaterial
Siemens ST 80 / ST PC · 2013
5/29
5
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
■ Overview
■ Technical specifications
SIMATIC IPC227D
General features
5
SIMATIC IPC227D (Nanobox PC):
The compact embedded IPC – maintenance-free and
dust-proof with versatile mounting
• Maximum compactness with approx. 1 liter enclosure volume
or more with integrated industrial power supply for minimum
space requirements in the control cabinet
• Maximum flexibility thanks four mounting options and interfaces on one side suitable for every installation situation
• Optimum variety of interfaces due to a large number of
integrated interfaces such as a selectable serial port
(RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN
• Maximum industrial functionality due to closed enclosure for
optimum dust protection and non-volatile retentive memory
• Further device options for optimum adaptation to the application with additional PCIe slot or R S232 interfaces or
digital I/O
Design
Rail, wall, portrait or side mounting
Processor
• Intel Atom E620 600 MHz,
512 MB RAM
• Intel Atom E640 1.0 GHz,
1 GB RAM
• Intel Atom E660 1.3 GHz,
2 GB RAM
Chipset
Intel Controller Hub EG20T
Buffered MRAM
optional, 512 KB, of which 128 KB
can be written within the buffer time
Free slots for expansions
Optional PCIe expansion slot
Graphics
• Integrated into Intel Atom CPU E6xx
• 8 to 256 MB (shared memory),
1920 x 1200, 60 Hz, 32-bit colors
Operating system
• Without
• Windows Embedded Standard
2009 preinstalled, in combination
with CF card or solid-state drive or
hard drive (optional)
• Windows XP Professional MUI preinstalled (in combination with solidstate drive or hard drive; MUI: Multi
Language User Interface) (optional)
• Windows Embedded Standard 7,
32-bit, preinstalled, in combination
with CF card or solid-state drive or
hard drive (optional)
• Windows 7 Ultimate MUI 32 bit preinstalled (in combination with solidstate drive or hard drive; MUI: Multi
Language User Interface) (optional)
• Linux 1)
(project-specific, on request)
• RMOS (project-specific on request)
• Others on request project-specifically
Design
Rail, wall, portrait or side mounting
Power supply
• 24 V DC (20.4 V ... 28.8 V)
• Isolated
• With buffering of temporary power
failures: max. 10 ms
• Line side switch
• With power failure indication by
means of Power Fail signal
1)
5/30
Siemens ST 80 / ST PC · 2013
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
■ Technical specifications (continued)
SIMATIC IPC227D
Drives
Flash drive
SIMATIC IPC227D
Monitoring functions
Optional; replaceable, accessible,
diagnosable
• 2 GB
• 4 GB
• 8 GB
• 16 GB
• Processor temperature
• Motherboard
Temperature
Messages can be evaluated by the
application program
Solid-state drive (SSD)
Optional
• 50 GB SATA, High Endurance, 2.5"
• 80 GB SATA, Standard, 2.5"
• Monitoring of program execution
• Monitoring time can be parameterized in software
• Can be parameterized for a fault or
restart
Hard disk
Optional
• 250 GB SATA
Messages can be evaluated by the
application program
CD-ROM
Via USB
(not included in scope of delivery)
DVD-RW
Via USB
(not included in scope of delivery)
Floppy disk
Via USB
(not included in scope of delivery)
Watchdog
Monitoring functions via the network
Remote monitoring capability for:
• Watchdog
• Temperature
• Mass memory monitoring (SMART)
• System/Ethernet monitoring
(Heart Beat)
• Runtime meter
Interfaces
PROFINET
PROFINET RT via Standard Ethernet
controller
PROFIBUS/MPI
-
Ethernet
• 2 x 10/100/1000 Mbps (RJ 45)
• Two independent Intel Controllers:
Intel 82574L / Intel Controller Hub
EG20T
• With teaming function
USB
V2.0: 4 x
Serial
COM1 (V.24), optional COM2-4
DVI-I
1 x DVI-D
Keyboard
Via USB (not included in scope of
delivery)
Mouse
Via USB (not included in scope of
delivery)
• DiagBase
• SIMATIC IPC DiagMonitor
Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in
SIMATIC software
• Configuration of client/server architectures
• Structure of log files
Ambient conditions
Degree of protection to EN 60529
(front/rear)
IP40
Vibration load during operation
Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-6, Test Fc
• 10-58: 0.0375 mm
• 58-200: 9.8 m/s2
• 10 x /axis
Devices with hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-6, Test Fc
• 10-58: 0.0375 mm
• 58-200: 4.9 m/s2
• 10 x /axis
Shock loading during operation
Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-27, Test Ea
• 150 m/s2, 30 ms shock duration
Devices with hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-27, Test Ea
50 m/s2, 30 ms shock duration
Moist heat
With CompactFlash card/SSD: 95 %
With hard disk: 80 %
Ambient temperature
during operation
0 °C up to 50 °C
Siemens ST 80 / ST PC · 2013
5/31
5
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
■ Technical specifications (continued)
SIMATIC IPC227D
Electromagnetic compatibility
(EMC)
SIMATIC IPC227D
Approvals
Emitted interference
EN 55022 Class B
Interference immunity, burst
EN 61000-6-2 or IEC 61131-2:
• 2 kV - tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetrical - tested acc. to IEC 61000-4-5
Interference immunity, surge
• 1 kV to IEC 61000-4-5; symmetrical
• 2 kV to IEC 61000-4-5; asymmetrical
Marine approval
Only for configurations with
CompactFlash or SSD memory
•
•
•
•
•
•
GL – Germanische Lloyd
BV – Bureau Veritas
LR – Lloyds Register of Shipping
ABS – American Bureau of Shipping
DNV – Det Norske Veritas
NKK – Nippon Kaiji Kyokai
Device versions
Basic version
Width x Height x Depth:
approx. 191 x 100 x 60 mm
ESD interference immunity
According to NAMUR Recommendation NE 21 and EN 61000-6-2:
• 6 kV contact discharge - tested acc.
to IEC 61000-4-2
• 8 kV air discharge - tested acc. to
IEC 61000-4-2
COM
• 3 additional, integrated
serial interfaces
(COM2-4);
only sending/receiving of data
• Width x Height x Depth:
approx. 191 x 100 x 89 mm
Immunity to high radio frequency
interference
According to EN 61000-6-2 or
IEC 61131-2:
• Interference immunity 80 ... 1000
MHz: 10 V/m with 80% AM (1 kHz);
tested acc. to IEC 61000-4-3;
• 1.4 GHz ... 2 Hz: 10 V/m with 50%
pulse modulation; tested according
to IEC 61000-4-3
IO
• 4 digital inputs/outputs each, 24 V,
integrated
• Width x Height x Depth:
approx. 191 x 100 x 89 mm
PCIe
• 1 PCIe (x1) slot, integrated
• Width x Height x Depth:
approx. 191 x 187 x 89 mm
Immunity to high-frequency current
feed
Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:
• 10 kHz ... 80 MHz: 10 V
with 80% AM (1 kHz)
tested acc. to IEC 61000-4-6
Immunity to magnetic fields
Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2
or IEC 61131-2:
• 50/60 Hz; 100 A/m rms value tested acc. to IEC 61000-4-8
Release for individual order variants: See releases in the
ordering procedure.
5
5/32
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
■ Ordering data
SIMATIC IPC227D
Order No.
Order No.
6ES7647- 8 A 7 7 7 - 7 7 7 7
Atom E620 (600 MHz),
512 MB RAM,
without drive, with CF slot,
COM1: RS232, without operating
system,
device version: Base,
DIN rail,
1 x DVI-D graphics interface
2 x 10/100/1000 Mbps Ethernet
RJ45
4 x USB V2.0 (high current)
CompactFlash slot
24 V DC industrial power supply
Processors / memory configuration /
NVRAM
• Atom E620 (600 MHz), 512 MB
RAM
• Atom E620 (600 MHz), 512 MB
RAM, NVRAM
• Atom E640 (1.0 GHz), 1 GB RAM
• Atom E640 (1.0 GHz), 1 GB RAM,
NVRAM
• Atom E660 (1.3 GHz), 2 GB RAM
• Atom E660 (1.3 GHz), 2 GB RAM,
NVRAM
Drives
• Without drive, with CF slot
• 250 GB HDD SATA
• 50 GB Solid-State Drive SATA
(High Endurance)
• 80 GB Solid-State Drive SATA
(Standard)
• 2 GB SIMATIC IPC CompactFlash
• 4 GB SIMATIC IPC CompactFlash
• 8 GB SIMATIC IPC CompactFlash
• 16 GB SIMATIC IPC CompactFlash
COM interface
• COM1: RS232
• COM1: RS485
• COM1: CAN
Operating system
• Without operating system
• Windows Embedded Standard
2009 preinstalled
(CF from 2 GB/SSD/HD)
• XP Prof. MUI preinstalled
on SSD/HD
• Windows Embedded Standard 7
(32-bit) preinstalled
(CF from 4 GB/SSD/HD)
• Windows 7 (32-bit) MUI
preinstalled on SSD/HD
6ES7647- 8 A 7 7 7 - 7 7 7 7
SIMATIC IPC227D
Software bundles
• Without RTX/HMI software
• RTX: WinAC RTX 2010
• RTX-F: WinAC RTX F 2010
• HMI: WinCC RT Advanced 128 PT
• HMI: WinCC RT Advanced 512 PT
• HMI: WinCC RT Advanced
2048 PT
• HMI/RTX: RT 128 PT
• HMI/RTX: RT 512 PT
• HMI/RTX: RT 2048 PT
• HMI/RTX-F: RT 128 PT
• HMI/RTX-F: RT 512 PT
• HMI/RTX-F: RT 2048 PT
A
A
B
C
F
G
H
M
N
P
R
S
T
Device versions
• Device version: Base line
• Device version: PCIe (1 slot)
• Device version: COM
(COM2-4: RS232)
• Device version: IO
(4x dig. in/out each)
B
E
F
G
H
A
B
D
E
Mounting accessories
• Standard mounting rail
• Wall mounting
• Portrait mounting
• Side mounting
0
1
3
1
2
3
4
Release for individual order variants: See releases in the
ordering procedure.
4
5
6
7
8
Accessories
Cable strain relief set for IPC227D
Packing unit: 5 units
6ES7648-1AA50-0XL0
Dust protection set for IPC227D
6ES7648-1AA50-0XG0
5
0
1
2
0
1
2
3
4
Siemens ST 80 / ST PC · 2013
5/33
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
46
28
4.8
21.5
4.8
19
21
220
231.5
198
220
231.5
20.3
14.5
15
197
76.6
56
2.5
105
SIMATIC IPC227D basic unit, portrait mounting
93.1
G_ST80_XX_00475
100
90.6
G_ST80_XX_00474
60
62
2
100
105
SIMATIC IPC227D COM version, portrait mounting
5
60
SIMATIC IPC227D basic unit, standard rail mounting
5/34
Siemens ST 80 / ST PC · 2013
100
50
8.5
SIMATIC IPC227D COM version, standard rail mounting
G_ST80_XX_00465
8.5
G_ST80_XX_00464
50
100
90.6
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
■ Dimensional drawings (continued)
■ More information
76.6
56
4.8
21
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
20.3
220
198
231.5
14.5
G_ST80_XX_00476
90.6
93.1
2.5
187
192
SIMATIC IPC227D PCIe version, portrait mounting
5
8.5
G_ST80_XX_00473
93.5
167
90.6
SIMATIC IPC227D PCIe version, standard rail mounting
Siemens ST 80 / ST PC · 2013
5/35
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427D
■ Overview
SIMATIC IPC427D (Microbox PC):
The powerful embedded IPC – maintenance-free
with versatile configuration
Ready-to-run, complete solutions (software is already installed
and preconfigured) for visualization and automation in
connection with WinCC RT Advanced and/or WinAC RTX:
• Ultra-compact
• Maintenance-free
• Third generation Intel Core i technology
■ Technical specifications
SIMATIC IPC427D
Design
• DIN rail mounting
• Wall mounting
• Portrait mounting
• Intel Celeron 827E 1.4 GHz,
1.5 MB SLC
• Intel Core i3-3217UE 1.6 GHz,
3 MB SLC
• Intel Core i7-3517UE 1.7 GHz,
4 MB SLC
Processor
SIMATIC IPC427D
USB stick
General features
External, can be connected
via USB port
Interfaces
Serial
• COM1 (RS 232)
• COM2 (RS 232); optional
Graphics
• DVI-I: Can be used as DVI or VGA
• DPP++: Display port, DVI via
DPP-to-DVI adapter
USB
Memory module without ECC:
• 1 GB DDR3-SDRAM SODIMM
• 2 GB DDR3-SDRAM SODIMM
• 4 GB DDR3-SDRAM SODIMM
• 8 GB DDR3-SDRAM SODIMM
4 x USB 3.0, max. 2 high-current at
the same time, downward-compatible
with USB 2.0/1.1
Ethernet
Memory module with ECC:
• 4 GB DDR3-ECC SODIMM
• 8 GB DDR3-ECC SODIMM
• 2 x RJ45 (10/100/1000 Mbps)
teaming-capable or
• 1 x RJ45 (10/100/1000 Mbps)
with PROFINET versions
PROFIBUS DP
12 Mbps (isolated, compatible with
CP 5622), optional
Free slots for expansions
Up to 2 x PCIe cards, depending on
enclosure design
PROFINET
3 x RJ45 (10/100 Mbps),
CP 1616 onboard, optional
Graphics
• Integrated Intel HD2000 or HD4000
• DVI resolution of 640 x 480 pixels up
to 1920 x 1200 pixels
• Maximum display port resolution
1920 x 1200 pixels
• Graphics memory is occupied in the
main memory (UMA dynamic)
CAN interface
Optional
Keyboard, mouse
Connection via USB port
Main memory
5
Power supply
24 V DC (-20%/+20%) max. 4 A
Rated conditions
Fan-free operation
Advanced device functions
Temperature
• When permitted operating
temperature range is exceeded
• Warnings can be analyzed by the
application program (local, via LAN)
Watchdog
• Monitoring function for program
execution
• Restart can be parameterized in the
event of a fault
• Warnings can be analyzed by the
application program (local, via LAN)
LED display
4 LEDs for displaying system status,
3 of these can be programmed by the
user
Short-term voltage dip
Up to 15 ms buffer time at full load
Buffer memory
512 KB MRAM optional
Operating systems
Available
• without
• Windows Embedded Standard 7
• Windows 7 Ultimate MUI
Project-specific
• Linux
• QNX
• VxWorks
Drives and storage media
CFast card
•
•
•
•
Hard disk
• 2.5", 1 x t 250 GB, SATA
Solid-state drive (SSD)
• 1 x t 50 GB, 2.5" SATA-SSD,
high endurance or
• 1 x t 80 GB, 2.5" SATA-SSD,
standard or
• 1 x t 160 GB, 2.5" SATA-SSD,
standard
5/36
2 GB optional or
4 GB optional or
8 GB optional or
16 GB optional
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427D
■ Ordering data
SIMATIC IPC427D (Box PC) 1) 2)
Processor and fieldbus:
• Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN)
• Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
• Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN);
CAN interface
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
2 x Gigabit Ethernet (IE/PN)
• Core i3-3217UE
(2C/4T, 1.6 GHz,3 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
1 x Gigabit Ethernet (IE/PN);
1 x PROFINET (IRT, 3 ports)
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache); 2 x Gigabit Ethernet
(IE/PN) (optional ECC only here)
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz, 3 MB
cache); 2 x Gigabit Ethernet
(IE/PN); PROFIBUS DP12
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz, 3 MB
cache); 1 x Gigabit Ethernet
(IE/PN); 1 x PROFINET
(IRT, 3 ports)
Mounting accessories:
• DIN rail mounting
• Wall mounting
• Portrait mounting
Work memory/NVRAM/ECC:
• 1 GB
• 2 GB
• 4 GB
• 8 GB
• 4 GB with ECC (only with Core i7,
2 x Gigabit Ethernet (IE/PN))
• 8 GB with ECC (only with Core i7,
2 x Gigabit Ethernet (IE/PN))
• 1 GB and NVRAM
• 2 GB and NVRAM
• 4 GB and NVRAM
• 8 GB and NVRAM
• 4 GB with ECC and NVRAM (only
with Core i7, 2 x Gigabit Ethernet
(IE/PN))
• 8 GB with ECC and NVRAM (only
with Core i7, 2 x Gigabit Ethernet
(IE/PN))
Expansions/interface:
• One RS 232, without PCIe
• One RS 232 and one PCIe
• One RS 232 and two PCIe
• Second RS 232, without PCIe
• Second RS 232 and one PCIe
• Second RS 232 and second PCIe
Operating system:
• Without operating system
• Windows Embedded Standard 7
SP1, English, 32-bit
• Windows 7 Ultimate SP1, 32-bit,
MUI (Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate SP1, 64-bit,
MUI (Eng, Ger, Fr, It, Sp)
Order No.
Order No.
6AG4140- 7 7 7 7 7 - 7 7 7 7
SIMATIC IPC427D (Box PC) 1) 2)
(continued)
6AG4140- 7 7 7 7 7 - 7 7 7 7
Mass storage, externally accessible:
• Without external mass storage
• CFast 2 GB
Without operating system
• CFast 4 GB
(only optionally with operating system if no internal mass storage)
• CFast 8 GB
(only optionally with operating system if no internal mass storage)
• CFast 16 GB
(only optionally with operating system if no internal mass storage)
0
1
2
3
Internal mass storage:
• Without internal mass storage
• CFast 2 GB, without software
• CFast 4 GB, without software
• CFast 8 GB, without software
• CFast 16 GB, without software
• SSD 50 GB high endurance (SLC)
• SSD 80 GB Standard
• HDD 250 GB
• SSD 160 GB Standard
4
5
6
SIMATIC software preinstalled
(bundles, only with Windows
Embedded Standard 7):
• Without SIMATIC software
• WinAC RTX 2010 3)
• WinCC RT Advanced, 128 PT
• WinCC RT Advanced, 512 PT
• WinCC RT Advanced, 2048 PT
• WinCC RT Advanced, 4096 PT
• WinCC RT Advanced 128 PT,
WinAC RTX 2010 3)
• WinCC RT Advanced 512 PT,
WinAC RTX 2010 3)
• WinCC RT Advanced 2048 PT,
WinAC RTX 2010 3)
• WinCC RT Advanced 4096 PT,
WinAC RTX 2010 3)
• WinAC RTX F 2010 3)
• WinCC RT Advanced 128 PT,
WinAC RTX F 2010 3)
• WinCC RT Advanced 512 PT,
WinAC RTX F 2010 3)
• WinCC RT Advanced 2048 PT,
WinAC RTX F 2010 3)
• WinCC RT Advanced 4096 PT,
WinAC RTX F 2010 3)
7
8
B
D
E
A
B
C
D
G
H
J
K
L
M
N
Power supply:
• 24 V DC
industrial power supply
• 24 V DC and TPM
(not for China and Russia)
P
0
1
2
3
4
5
0
1
2
3
4
A
B
C
D
E
G
H
K
P
A
B
C
D
E
F
J
5
K
L
M
N
P
Q
R
S
0
8
1)
"Built to order" – versions with a delivery time of max. 15 working days and
with identified repair, if not preferred type.
2)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
3)
Only with "main memory and NVRAM".
Note:
0
4
Bundles with SIMATIC software only with Windows Embedded
Standard 7, main memory and NVRAM (with RTX and RTX F),
and CFast mass storage of 4 GB or more / SSD.
6
7
Siemens ST 80 / ST PC · 2013
5/37
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427D
■ Dimensional drawings
1.5
133
6.7
1.5
16.5
184
262
85
100
50
16.5
2
262
50
10
50.5
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC IPC427D, wall mounting
315
300
272
21.5
6.1
SIMATIC IPC427D, DIN rail mounting
5
25
15.3
143
55.5
61.5
G
SIMATIC IPC427D, portrait mounting
5/38
Siemens ST 80 / ST PC · 2013
G_ST80_XX_00555
8.9
2.5
5.8
G_ST80_XX_00554
286
297
G
50.5
G
9
G_ST80_XX_00553
6.7
133
83.7
Ø 4.5
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
■ Overview
■ Technical specifications
SIMATIC IPC427C
General features
Design
DIN rail or wall mounting, front upright
mounting, mounting position preferably horizontal, vertical possible
Processor
• Intel Core2 Duo 1.2 GHz,
800 MHz FSB, 3 MB SLC
• Intel Core2 Solo 1.2 GHz,
800 MHz FSB, 3 MB SLC
• Intel Celeron M 1.2 GHz,
800 MHz FSB, 1 MB SLC
Chipset
Intel GM45 / ICH9M
Main memory
1 GB, (2/4 GB) DDR3 SDRAM
Buffered SRAM
2 MB, of which 128 KB can be written
within the buffer time
Free slots for expansions
Up to 3 x PCI-104, 3 W per slot
Graphics
• Integrated Intel GMAX4500
graphics
• 8 ... 512 MB shared graphics memory (managed dynamically)
• CRT resolution: 640 x 480 pixels
up to max. 1920 x 1200 pixels at
32 bit colors
• DVI-D resolution: 640 x 480 pixels
up to max. 1920 x 1200 pixels at
32 bit colors
Operating system
• Without
• Windows XP Embedded Standard
2009 preinstalled, in combination
with CF card of 2 GB or more,
solid-state drive, or hard drive
• Windows XP Professional MUI
(in combination with solid-state
drive or hard drive; MUI:
Multi Language User Interface)
• Windows 7 Ultimate MUI (in combination with solid-state drive or hard
drive; MUI: Multi Language User
Interface)
• Windows Embedded Standard 7
preinstalled, in combination with CF
card of 4 GB or more, or solid-sate
drive, or hard drive RMOS3 (can be
ordered separately)
• Linux1)
(project-specific, on request)
• Others on request project-specifically
SIMATIC IPC427C (Microbox PC): The powerful embedded
IPC – maintenance-free with versatile configuration
• Ultra-compact
• Maintenance-free
• Intel Core2 Duo technology
Power supply
1)
• 24 V DC (19.2 V ... 28.8 V)
• Isolated
• With buffering of temporary power
failures: Max. 10 ms at 0.85% rated
voltage
• Line side switch
• With power failure indication by
means of Power Fail signal
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
Siemens ST 80 / ST PC · 2013
5/39
5
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
■ Technical specifications (continued)
SIMATIC IPC427C
Drives
Flash drive
Optional; replaceable, accessible,
diagnosable
• 2 GB
• 4 GB
• 8 GB
• 16 GB
Optional; internal, not accessible,
diagnosable
• 2 GB
• 4 GB
• 8 GB
• 16 GB
Solid-State Drive (SSD)
Optional
• 50 GB SATA, 2.5" in single-level cell
(SLC) architecture (High Endurance), especially suitable for
industrial applications
• 80 GB SATA, 2.5" Standard
Hard disk
Optional
• > 250 GB SATA
CD-ROM
Via USB
(not included in scope of delivery)
DVD-RW
Via USB
(not included in scope of delivery)
Diskette
Via USB
(not included in scope of delivery)
Temperature
• Processor temperature
• Motherboard
• Messages can be evaluated by the
application program
Watchdog
• Monitoring of program execution
• Monitoring time can be parameterized in software
• Can be parameterized for a fault or
restart
• Messages can be evaluated by the
application program.
Monitoring functions via the network
• DiagBase
• SIMATIC IPC DiagMonitor
Remote monitoring capability for:
• Watchdog
• Temperature
• Mass memory monitoring (SMART)
• System/Ethernet monitoring
(Heart Beat)
• Runtime meter
Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in
SIMATIC software
• Configuration of client/server
architectures
• Layout of log files
Ambient conditions
Interfaces
PROFINET
3 x RJ45
(CP 1616-compatible, optional)
PROFIBUS/MPI
12 Mbit/s
(isolated, compatible to CP 5611)
optional
Ethernet
• 2 x 10/100/1000 Mbit/s (RJ 45)
• Two independent Intel 82574L
controllers (via PCI-Express)
• One controller with none-shared
interrupt
• With teaming function
USB
V2.0/High Speed: 4 x
Serial
COM1 (V.24)
COM2 (V.24) optional
(in expansion frame)
DVI-I
1 x DVI-I (includes DVI-D and VGA)
Keyboard
Via USB
(not included in scope of delivery)
Mouse
Via USB
(not included in scope of delivery)
5
SIMATIC IPC427C
Monitoring functions
Degree of protection to EN 60529
(front/rear)
IP20
Vibration load during operation
Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-6, Test Fc
• Devices without drive:
- 5-9 Hz, 3.5 mm deviation,
10x /axis, 1 octave/min
- 9-150 Hz, 9.8 m/s2, 10x /axis,
1 octave/min
Devices with hard disk:
Wall mounting
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-6, Test Fc
• 10 ... 58 Hz, 0.0375 mm deviation,
10x /axis, 1 octave/min
• 58 ... 200 Hz, 4.9 m/s2, 10x /axis,
1 octave/min
Shock loading during operation
Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-27, Test Ea
• Module/rack: 150 m/s2, power-up,
11 ms shock duration
Devices with hard disk:
Wall mounting
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-27, Test Ea
• Devices with drive: 50 m/s2,
power-up, 30 ms shock duration
5/40
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
■ Technical specifications (continued)
SIMATIC IPC427C
Electromagnetic compatibility
(EMC)
• Emitted interference
• Interference immunity, burst
• Interference immunity, surge
• ESD interference immunity
• Immunity to high radio frequency
interference
• Immunity to high-frequency
current feed
• Immunity to magnetic fields
EN 55022 Class B
EN 61000-6-2 or IEC 61131-2:
• 2 kV - Tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetrical - Tested acc. to IEC 61000-4-5
1 kV to IEC 61000-4-5; symmetrical
2 kV to IEC 61000-4-5; asymmetrical
According to NAMUR Recommendation NE 21 and EN 61000-6-2:
• 6 kV contact discharge Tested acc. to IEC 61000-4-2
• 8 kV air discharge Tested acc. to IEC 61000-4-2
According to EN 61000-6-2 or
IEC 61131-2:
• Interference immunity
80 ... 1000 MHz: 10 V/m with
80% AM (1 kHz); tested acc. to
IEC 61000-4-3;
• 1.4 GHz ... 2 Hz: 10 V/m with 50%
pulse modulation; tested according
to IEC 61000-4-3
Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:
• 10 kHz ... 80 MHz:
10 V with 80% AM (1 kHz)
tested acc. to IEC 61000-4-6
Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:
SIMATIC IPC427C
System-tested
SIMATIC Industrial Software
WinAC RTX (F), WinCC flexible,
WinCC (SCADA as of V7.0), WinCC
RT Advanced and Professional
Approvals
UL508, UL60950, cULus
Marine approval
•
•
•
•
•
•
Only for configurations with
CompactFlash or SSD memory
Safety regulations
• IEC 61131-2
• IEC 61010-1
• EN 60950-1
CE mark
• EC Directive 89/336/EEC
(EMC Directive)
• Use in industry:
• Applications in residential areas,
business and trade environments as
well as in workshops:
- Emitted interference:
EN 61000-6-4
- Noise immunity: EN 61000-6-2
• Applications in residential areas,
business and trade environments as
well as in workshops:
- Emitted interference:
EN 61000-6-3
- Noise immunity: EN 61000-6-1
Dimensions and weights
Equipment dimensions (in mm)
•
•
•
•
Weight, approx.
2 kg
50/60 Hz; 100 A/m rms value
- tested acc. to IEC 61000-4-8
Ambient temperature
during operation
Moist heat
• 0 ... 55 ºC with flash drive/SSD
(horizontal; preferred mounting
position; with derating)
• 0 ... 50 ºC with flash drive/SSD
(horizontal; preferred mounting
position; maximum configuration)
• 0 ... 50 ºC with flash drive/SSD
(vertical)
• 5 ... 40 ºC with hard disk
(horizontal and vertical)
GL - Germanische Lloyd
BV - Bureau Veritas
LR - Lloyds Register of Shipping
ABS - American Bureau of Shipping
DNV - Det Norske Veritas
NKK - Nippon Kaiji Kyokai
Width x height: 262 x 134
Depth of basic unit: 47
Depth of basic unit above rail: 50
Additional depth per expansion
(1-3): 17 each
5
• With CompactFlash card/SSD: 95 %
• With hard drive 80%
Siemens ST 80 / ST PC · 2013
5/41
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
■ Ordering data
SIMATIC IPC427C 1)
Order No.
Order No.
6ES7647- 7 B 7 7 7 - 7 7 7 0
Memory expansion
• 1 GB DDR3 1066 SDRAM,
SODIMM
• 2 GB DDR3 1066 SDRAM,
SODIMM
• 4 GB DDR3 1066 SDRAM,
SODIMM
Intel Celeron M 1.2 GHz, 800 MHz
FSB, SLC 0 KB; 512 MB DDR3
RAM; without HD; without flash
drive; without operating system;
24 V DC industrial power supply
Processor:
• Intel Celeron M 1.2 GHz,
800 MHz FSB
• Intel Celeron M 1.2 GHz,
800 MHz FSB, PROFIBUS
• Intel Celeron M 1.2 GHz,
800 MHz FSB, CAN
• Core2 Solo 1.2 GHz,
800 MHz FSB SLC, 3 MB
• Core2 Solo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFIBUS
• Core2 Solo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFINET
• Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB
• Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFIBUS
• Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFINET
A
B
D
E
F
G
J
K
L
Memory configuration:
• 1 GB DDR3 1066, SODIMM
• 2 GB DDR3 1066, SODIMM
• 4 GB DDR3 1066, SODIMM
Expansion (HW):
• No expansion (HW)
• Second RS232 interface
in expansion rack
5
Drives exchangeable (accessible)
• Without drive
• 2 GB CompactFlash
• 4 GB CompactFlash
• 8 GB CompactFlash
• 16 GB CompactFlash
2
3
4
6ES7648-2AH40-0KA0
6ES7648-2AH50-0KA0
6ES7648-2AH60-0KA0
Expansion kit PC/104
For integration of PC/104 modules in
the SIMATIC Microbox PC; packing
unit contains 6 expansion frames
6AG4070-0BA00-0XA0
SIMATIC PC adapter cable
DVI-I acc. to VGA, 250 mm
6ES7648-3AB00-0XA0
SIMATIC PC DVI-I Y graphics
adapter cable
DVI-I to VGA and DVI-D
6ES7648-3AE00-0XA0
Portrait assembly kit
Interfaces to the front
6ES7648-1AA20-0YB0
Expansion components
From page 5/153
Communication products
From page 5/186
For power supplies and
uninterruptible power supplies
From page 5/170
RMOS3 real-time operating
system
From page 5/146
0
1
0
2
3
4
5
Drives internal (not accessible)
• Without internal drive
• 250 GB HDD SATA
• 50 GB SSD High Endurance SATA
• 80 GB Standard SATA
• 2 GB CompactFlash internal
• 4 GB CompactFlash internal
• 8 GB CompactFlash internal
• 16 GB CompactFlash internal
Operating system
(preinstalled and activated)2)
• Without operating system
• Windows Embedded Standard
2009 English preinstalled on internal drive
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp) preinstalled on internal drive
• Windows Embedded Standard 7
preinstalled on internal drive
• Windows 7 Ultimate, 32-bit, MUI
(Eng, Ger, Fr, It, Sp) preinstalled on
internal drive
Accessories
X
A
D
E
N
P
Q
R
0
0
X
A
0
B
0
C
0
D
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
Note:
2)
XP Embedded on 2 GB CompactFlash or hard disk.
XP Professional or Windows 7 only with hard disk/SSD.
Ready-to-use SIMATIC IPC427C as bundles can be found
under "Embedded Bundles".
Software packages with SIMATIC WinCC flexible, SIMATIC
WinCC RT Advanced, SIMATIC WinCC, SIMATIC WinCC RT
Professional and SIMATIC WinAC RTX (F) can be ordered
together with the SIMATIC IPC with a price advantage.
5/42
Siemens ST 80 / ST PC · 2013
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
■ Dimensional drawings
SIMATIC IPC427Cb
262
138
G_ST80_XX_00456
46.5
*B67B;;B
138
133
262
52.5
97.5
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC IPC427C, interfaces
■ More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
5
Siemens ST 80 / ST PC · 2013
5/43
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC627C
■ Overview
■ Technical specifications
SIMATIC IPC627C
Supply voltage
Supply voltage
Processor
Processor
Interfaces
PROFIBUS/MPI
SIMATIC IPC627C (Box PC):
The high-end IPC – with maximum performance,
functional scope and expansion capability
It offers:
• Maximum performance in the smallest space
• Intel Core i7 technology
4x USB 2.0 high speed/high current
2 X PCI or 1xPCI & 1 x PCIe X16
(265 mm/185mm long) , 1xslot for
CompactFlash Card
Connection for keyboard/mouse
USB / USB
serial interface
COM1: 1 x V.24 (RS232)
Video interfaces
• Graphics interface
DVI-I: VGA / DVI combined
Industrial Ethernet
• Industrial Ethernet interface
2 x Fast Ethernet
Monitoring functions
Temperature
Yes
Watchdog
Yes
Status LEDs
Yes
Standards, approvals, certificates
Approval
CE, cULus (508), C-Tick
Vibrations
• Vibration load in operation
Shock testing
• Shock loading in operation
Operating systems
Operating system
Software
SIMATIC Software
Siemens ST 80 / ST PC · 2013
Onboard, isolated, max. 12 Mbit/s,
CP5611-compatible
Free slots
Ambient conditions
Relative humidity
• Relative humidity
5/44
Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4MB cache);
Core i3-330E (2C/4T, 2.13 GHz, HT,
VT, 3MB cache); Celeron P4505
(2C/2T, 1.86 GHz, VT, 2MB cache);
USB port
EMC
5
100 - 240 V AC, optional 24 V
CE, EN 55022A, EN 61000-6-4,
EN 61000-6-2
Tested to DIN IEC 68-2-3,
DIN IEC 68-2-30,
DIN IEC 68-2-56: 5% to 80%
at 25 °C (no condensation)
Tested to DIN IEC 68-2-6:
10 to 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/s2 (1 g)
Tested to DIN IEC 68-2-29:
50 m/s2 (5g), 30 ms, 100 shocks
Windows XP Prof. SP3, MUI;
Windows 7 Ultimate 32/64Bit, MUI;
Windows Embedded Standard 2009
English on 8 GB CompactFlash;
without operating system;
Optionally in package with
SIMATIC WinCC or WinCC flexible
Dimensions
Width
312 mm
Height
80 mm; with DVD drive: 100 mm
Depth
301 mm; incl. mounting rail
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC627C
■ Ordering data
SIMATIC IPC627C 1)
Order No.
Order No.
6ES7647- 6 C 7 7 7 - 7 7 7 7
HD graphics on-board,
128 MB dyn. shared memory;
2 x 10/100/1000 Mbps Ethernet
RJ45; 4 x USB V2.0 (high current);
1 x serial (COM1), RAID controller
on-board;
CompactFlash drive no. 1 at front
(without CF);
watchdog, temp./fan monitoring;
Processor:
• Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache)
• Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache), PROFIBUS/MPI
(CP5611-compatible),
2 MB battery-backed SRAM
• Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache), PROFINET
(3 x RJ45, CP1616-compatible),
2 MB battery-backed SRAM
• Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache)
• Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache),
PROFIBUS/MPI,
2 MB battery-backed SRAM
• Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache), PROFINET
(3 x RJ45, CP1616-compatible),
2 MB battery-backed SRAM
• Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache)
• Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache),
PROFIBUS/MPI,
2 MB battery-backed SRAM
• Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache),
PROFINET (3 x RJ45, CP1616compatible), 2 MB battery-backed
SRAM
Memory configuration
• 1 GB DDR3 1066 DIMM
• 2 GB DDR3 1066 DIMM
• 3 GB DDR3 1066 DIMM
• 4 GB DDR3 1066 DIMM
• 8 GB DDR3 1066 DIMM
• 2 GB DDR3 1066 DIMM, ECC
• 4 GB DDR3 1066 DIMM, ECC
• 8 GB DDR3 1066 DIMM, ECC
Country-specific version/
power supply
• 100/240 V AC industrial power
supply with Namur; European
cable
• 100/240 V AC industrial power
supply with Namur; UK cable
• 100/240 V AC industrial power
supply with Namur; Swiss cable
• 100/240 V AC industrial power
supply with Namur; USA cable
• 100/240 V AC industrial power
supply with Namur; Italian cable
• 100/240 V AC industrial power
supply with Namur; Chinese cable
• 24 V DC industrial power supply
Device Certification UL Class I
Div. 2; 24 V DC industrial
power supply
• Device Certification UL Class I
Div. 2; 110 / 230 V AC Industrial
Power Supply with Namur
SIMATIC IPC627C 1)
(continued)
6ES7647- 6 C 7 7 7 - 7 7 7 7
PC slots
• 2 x PCI free
• 1 x PCI, 1x PCIe (x16) free
0
1
Drives
• 250 GB HDD SATA
• 250 GB HDD SATA; DVD+/-RW
• 500 GB HDD SATA
• 500 GB HDD SATA; DVD+/-RW
• 2 x 250 GB SATA (2.5")
• 2 x 250 GB SATA (2.5") +
DVD+/-RW
• RAID1 2 x 250 GB SATA (2.5")
• RAID1 2 x 250 GB SATA (2.5");
DVD+/-RW
• 50 GB SATA solid-state drive (SLC)
• 50 GB SATA solid-state drive
(SLC); DVD+/-RW
• CompactFlash drive No. 2
installed, DVD+/-RW
• CompactFlash drive No. 2 installed
• DVD+/-RW
• Without drives
A
B
C
D
E
Operating system
(preinstalled and activated)
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included
• Windows Embedded Standard
2009 English on 8 GB
CompactFlash
• Without operating system
F
G
H
J
Expansion
• No expansion (software)
• SIMATIC IPC DiagMonitor software
included
• SIMATIC IPC Image&Partition
Creator software included
• SIMATIC IPC DiagMonitor,
Image & Partition Creator software
included
0
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
J
K
U
V
W
X
A
B
C
F
X
0
1
2
3
0
1
2
3
4
5
6
7
8
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
Siemens ST 80 / ST PC · 2013
5/45
5
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC627C
Order No.
SIMATIC PC,
230 V AC power cable
angled, 3 m for Box PC
and Panel PC for
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China
5
295.2
3.9
78.5
11.2
6ES7648-1AA10-0YA0
6ES7648-1AA10-0YB0
G_ST80_XX_00457
Portrait assembly kit
• Interfaces upward/downward
• Interfaces to the front
6ES7648-3AB00-0XA0
6ES7648-3AE00-0XA0
3.6
265
Graphics adapter cable
• DVI-I acc. to VGA, 250 mm long
• DVI-I acc. to VGA and DVI-D,
250 mm long (Y cable)
6ES7648-2CA01-0AA0
6ES7900-1AA00-0XA0
6ES7900-1BA00-0XA0
6ES7900-1CA00-0XA0
6ES7900-1DA00-0XA0
6ES7900-1EA00-0XA0
6ES7900-1FA00-0XA0
■ More information
Expansion components
From page 5/153
Further information can be found in the Internet under:
Communication products
From page 5/186
http://www.siemens.com/simatic-pc
For power supplies and
uninterruptible power supplies
From page 5/170
RMOS3 real-time operating
system
From page 5/146
Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".
5/46
Siemens ST 80 / ST PC · 2013
272.8
PCI expansion card
with COM1 and LPT
6ES7648-2AJ40-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ60-1KA0
99.8
All dimensions in mm. For mounting cut-out see technical specifications.
Accessories
Memory expansions
• 1 GB DDR3 1066, DIMM
• 1 GB DDR3 1066, DIMM; ECC
• 2 GB DDR3 1066, DIMM
• 2 GB DDR3 1066, DIMM; ECC
• 4 GB DDR3 1066, DIMM
• 4 GB DDR3 1066, DIMM; ECC
■ Dimensional drawings
99.1
■ Ordering data
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC827C
■ Overview
■ Technical specifications
SIMATIC IPC827C
Supply voltage
Supply voltage
100 - 240 V AC, optional 24 V
Processor
Processor
Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4MB cache);
Core i3-330E (2C/4T, 2.13 GHz, HT,
VT, 3MB cache); Celeron P4505
(2C/2T, 1.86 GHz, VT, 2MB cache);
Interfaces
PROFIBUS/MPI
SIMATIC IPC827C (Box PC):
The high-end IPC – with maximum performance,
functional scope and expansion capability
It offers:
• Maximum performance and high expandability
• with Intel Core i technology
Onboard, isolated, max. 12 Mbit/s,
CP5611-compatible
USB port
4x USB 2.0 high speed/high current
Free slots
3xPCI, 1 x PCIe (x4), 1 x PCIe (x16),
1xslot for CompactFlash Card
Connection for keyboard/mouse
USB / USB
serial interface
COM1: 1 x V.24 (RS232)
Video interfaces
• Graphics interface
DVI-I: VGA / DVI combined
Industrial Ethernet
• Industrial Ethernet interface
2 x Fast Ethernet
Monitoring functions
Temperature
Yes
Watchdog
Yes
Status LEDs
Yes
Standards, approvals, certificates
Approval
CE, cULus (508), C-Tick
EMC
Ambient conditions
Relative humidity
• Relative humidity
Vibrations
• Vibration load in operation
Shock testing
• Shock loading in operation
Operating systems
Operating system
Software
SIMATIC Software
CE, EN 55022A, EN 61000-6-4,
EN 61000-6-2
Tested to DIN IEC 68-2-3,
DIN IEC 68-2-30,
DIN IEC 68-2-56: 5% to 80%
at 25 °C (no condensation)
Tested to DIN IEC 68-2-6:
10 to 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/s2 (1 g)
Tested to DIN IEC 68-2-29:
50 m/s2 (5g), 30 ms, 100 shocks
Windows XP Prof. SP3, MUI;
Windows 7 Ultimate 32/64Bit, MUI;
Windows Embedded Standard 2009
English on 8 GB CompactFlash;
without operating system;
Optionally in package with
SIMATIC WinCC or WinCC flexible
Dimensions
Width
312 mm
Height
150 mm; with DVD drive: 170 mm
Depth
301 mm; incl. mounting rail
Siemens ST 80 / ST PC · 2013
5/47
5
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC827C
■ Ordering data
SIMATIC IPC827C
Order No.
Processor
• Celeron P 4505
(2C/2T, 1.86 GHz, VT, 2 MB cache)
• Celeron P 4505
(2C/2T, 1.86 GHz, VT,
2 MB cache); PROFIBUS/MPI;
2 MB battery-backed SRAM
• Celeron P 4505
(2C/2T, 1.86 GHz, VT,
2 MB cache);
PROFINET (3 x RJ45,
CP1616-compatible);
2 MB battery-backed SRAM
• Core i3-330E
(2C/4T, 2.13 GHz, HT, VT,
3 MB cache)
• Core i3-330E
(2.13 GHz, HT, VT,
3 MB cache); PROFIBUS/MPI;
2 MB battery-backed SRAM
• Core i3-330
(2C/4T, 2.13 GHz, HT, VT,
3 MB cache); PROFINET
(3 x RJ45, CP1616-compatible);
2 MB battery-backed SRAM
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache)
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache);
PROFIBUS/MPI;
2 MB battery-backed SRAM
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache);
PROFINET
(3 x RJ45, CP1616-compatible);
2 MB battery-backed SRAM
5
Memory configuration
• 1 GB DDR3 1066 DIMM
• 2 GB DDR3 1066 DIMM
• 3 GB DDR3 1066 DIMM
• 4 GB DDR3 1066 DIMM
• 8 GB DDR3 1066 DIMM
• 2 GB DDR3 1066 DIMM, ECC
• 4 GB DDR3 1066 DIMM, ECC
• 8 GB DDR3 1066 DIMM, ECC
Power supply
• 100/240 V AC industrial power
supply with Namur;
European cable
• 100/240 V AC industrial power
supply with Namur; UK cable
• 100/240 V AC industrial power
supply with Namur; Swiss cable
• 100/240 V AC industrial power
supply with Namur; USA cable
• 100/240 V AC industrial power
supply with Namur; Italian cable
• 100/240 V AC industrial power
supply with Namur; Chinese cable
• 24 V DC industrial power supply
5/48
Order No.
6ES7647- 6 P 7 7 7 - 7 7 7 7
Siemens ST 80 / ST PC · 2013
SIMATIC IPC827C
(continued)
Expansions (HW)
• 3 x PCI, 2 x PCIe (x4),
1 x PCIe (x16) available
A
B
Mass storage
• 250 GB HDD SATA
• 250 GB HDD SATA; DVD+/-RW
• 500 GB HDD SATA
• 500 GB HDD SATA; DVD+/-RW
• 2 x 250 GB SATA (2.5")
• 2 x 250 GB SATA (2.5") +
DVD+/-RW
• RAID1 2 x 250 GB SATA (2.5")
• RAID1 2 x 250 GB SATA (2.5");
DVD+/-RW
• Solid-state drive 50 GB (SLC)
• Solid-state drive 50 GB (SLC);
DVD+/-RW
• DVD+/-RW
• Without drives
C
D
E
F
Operating system
(preinstalled and activated)
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate, 32-bit, MUI
(Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate, 64-bit, MUI
(Eng, Ger, Fr, It, Sp)
• Windows XP Embedded Standard
2009 English on
8 GB CompactFlash
• Without operating system
G
H
J
Expansion software
• No expansion (software)
• SIMATIC IPC DiagMonitor software
included
• SIMATIC IPC Image&Partition
Creator included
• SIMATIC IPC DiagMonitor &
Image & Partition Creator included
0
1
2
3
4
5
6
7
6ES7647- 6 P 7 7 7 - 7 7 7 7
0
A
B
C
D
E
F
G
H
J
K
W
X
A
B
C
F
X
0
1
4
5
Note:
Windows Embedded only without
RAID option
0
1
2
3
4
5
6
Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC827C
Order No.
All dimensions in mm. For mounting cut-out see technical specifications.
Accessories
Portrait assembly kit
• Interfaces upward/downward
• Interfaces to the front
Power supply cable
SIMATIC PC, power cable for
230 V AC, angled, 3 m for Box PC
and Panel PC for
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China
173.2
3
6ES7648-3AB00-0XA0
6ES7648-3AE00-0XA0
295.2
11
6ES7648-1AA30-0YA0
6ES7648-1AA30-0YB0
6ES7900-1AA00-0XA0
6ES7900-1BA00-0XA0
6ES7900-1CA00-0XA0
6ES7900-1DA00-0XA0
6ES7900-1EA00-0XA0
6ES7900-1FA00-0XA0
297.2
G_ST80_XX_00458
Graphics adapter cable
• DVI-I acc. to VGA, 250 mm long
• DVI-I acc. to VGA and DVI-D,
250 mm long (Y cable)
6ES7648-2CA01-0AA0
2.4
PCI expansion card
with COM1 and LPT
6ES7648-2AJ40-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ60-1KA0
269.8
Memory expansions
• 1 GB DDR3 1066, DIMM
• 1 GB DDR3 1066, DIMM; ECC
• 2 GB DDR3 1066, DIMM
• 2 GB DDR3 1066, DIMM; ECC
• 4 GB DDR3 1066, DIMM
• 4 GB DDR3 1066, DIMM; ECC
■ Dimensional drawings
265
■ Ordering data
■ More information
Expansion components
From page 5/153
Weitere Informationen finden Sie im Internet unter:
Communication products
From page 5/186
http://www.siemens.com/simatic-pc
For power supplies and uninterruptible power supplies
From page 5/170
RMOS3 real-time operating
system
From page 5/146
5
Siemens ST 80 / ST PC · 2013
5/49
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
Panel PC
■ Overview
SIMATIC IPC277:
The embedded Nanopanel PC – maintenance-free and
compact with displays starting from 7"
• High degree of flexibility for selecting rugged widescreen
fronts from 7" to 19&qu