Electrical Measuring Instruments General Catalog

Electrical Measuring Instruments General Catalog
2007 - 2008
Electrical Measuring Instruments
General Catalog
www.hioki.com
About the Catalog
Searching for product pages and notes ...
Products in this catalog are grouped according to functions
so you can easily find the right instrument for your
application by referring to the list of product groups in the
table of contents on the first page, and moving directly to
the indicated section.
Dimensions and mass:
Exterior dimensions exclude protrusions, and are given in
order of width(W), height(H), and depth(D), in mm units.
Indicated weight represents an approximation of the mass
of the main unit only, not including case, accessories, etc.
About the marks ...
New products in the 2006 Electrical
Measuring Instruments GENERAL
CATALOG.
True RMS measuring capability for
accurate measurement of even distorted
waveforms.
Models are available with interfaces compatible with LAN, GP-IB, RS-232C,
SCSI, FAX/modem and USB standards.
Measurement categories (Overvoltage categories)
To ensure safe operation of measurement products, IEC 61010 establishes safety standards for various electrical
environments, categorized as CAT I to CAT IV, and called measurement categories. These are defined as follows.
CAT I : Secondary electrical circuits connected to an AC electrical outlet through a transformer or similar device.
CAT II : Primary electrical circuits in equipment connected to an AC electrical outlet by a power cord (portable
tools, household appliances, etc.)
CAT III : Primary electrical circuits of heavy equipment (fixed installations) connected directly to the distribution
panel, and feeders from the distribution panel to outlets.
CAT IV : The circuit from the service drop to the service entrance, and to the power meter and primary overcurrent
protection device (distribution panel).
Higher-numbered categories correspond to electrical environments with greater momentary energy, so a
measurement product designed for CAT III environments can endure greater momentary energy than one designed
for CAT II. Using a measurement product
in an environment designated with a
higher-numbered category than that for
which the product is rated could result in
Distribution Panel
a severe accident, and must be carefully
Service Entrance
avoided.
Internal Wiring
Service Drop
Never use a CAT I measuring product in
CAT II, III, or IV environments.
T
The measurement categories comply
Outlet
with the Overvoltage Categories of the
Power Meter
IEC60664 Standards.
Fixed Installation
What is the CE Mark?
The CE mark certifies that a product
complies with electrical safety standards
established by European Community
directives (EC directives). These EC directives require
conformance of a product to EN/IEC standards for
electrical safety.
•HIOKI's products bearing the CE Mark are designed to
confirm to the Low Voltage and EMC directives based
on the EC directives.
•The Low Voltage directive is applicable to products
operating from 50 to 1000V AC and 75 to 1500V DC,
and require protection from electrical hazards such as
electric shock.
•The EMC directive requires suppression of emissions
of harmful electromagnetic radiation, and the ability
to withstand exposure to external electromagnetic
radiation without malfunction.
In some cases, power lines may carry
voltage spikes of several times the
normal supply voltage. For reasons of
safety, ordinary testers should not be
used to measure power lines carrying
more than 250V. When measuring such power lines,
always use a tester with built-in overcurrent protection
to guard against short circuits, such as Model 3008 and
CAT III marked products.
Note : An industrial power line refers to a high-capacity
supply circuit to equipment in factories or offices. A
high-capacity supply circuit refers generally to a line
carrying 20 A or more. This does not therefore include
supply lines protected by overcurrent protection (fuses) or
distribution breakers.
Notes on accuracy ...
The specifications in this catalog include figures for
"measurement accuracy" when referring to digital
measuring instruments, and for "measurement
tolerance" when referring to analog instruments.
The accuracy and tolerance figures in the product
specifications are defined in terms of full scale
(f.s.) value and displayed reading (rdg.) or digit
resolution (dgt.) as described below.
rdg. (displayed or indicated value, ... reading value)
f.s. (maximum
full-scale)
dgt. (digital resolution, ... digit)
Signifies the smallest display unit on a digital measuring
instrument, i.e., the value displayed when the last digit
on the digital display is "1". Essentially, this indicates
an error of 1 digit (based on decimal processing in
analog-to-digital conversion), but in actuality this is
the digit error combined with the f.s. error converted to
a fraction of a digit unit. The accuracy associated with
a particular measured value as shown in the product
specifications is derived from these values.
display, or length of scale, ...
Signifies the maximum display (scale) value or the
length of the scale (in cases where the scale consists
of unequal increments or where the maximum value
cannot be defined). In general, this is the range
value (the value written on the range selector, or
equivalent) currently in use. However, be aware that
in cases where the maximum display value is 2000V
but the range value is only 600V, the maximum
display value (scale value) is still used as the f.s.
value.
1
This signifies the value actually being measured, i.e.,
the value that is currently indicated or displayed by the
measuring instrument.
1. To avoid short circuits and electric
shock accidents when using a clamp-on
sensor, use only with power lines
carrying voltages within the rating limit
of the sensor.
2. To avoid short circuits and electric shock accidents
when the clamp-on sensor is open, do not use on bare
conductors.
Contents
About the Catalog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.1
Model Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.3
Recorders, Memory Recorders
P.4 to 15
Electronic Measuring Instruments P.16 to 26
Environmental Measuring Instruments P.27 to 30
Clamp Sensors
P.31 to 34
Power Measuring Instruments
P.35 to 40
Clamp Testers
P.41 to 46
Field Measuring Instruments
P.47 to 56
Options & Peripherals
P.57 to 64
Meter Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.57 to P.58
Test Leads, Test Probes . . . . . . . . . . . . . . . . . . . . . . P.59 to P.60
Electrodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.61
Recording Paper, Temperature Sensors . . . . . . . . . . . . . . . P.62
All Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.63 to P.64
Service, Traceability, Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.65
Company Guide & Internet Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.66
2
Model Index
1000 or later ...Peripherals
2000 or later ...Meter relays
1195. . . . . . . p.63
1196. . . . . . . p.63
7000 or later ...Signal sources
2103. . . . . . . p.57
2104. . . . . . . p.57
2300. . . . . . . p.28
7011. . . . . . .
7016. . . . . . .
7075. . . . . . .
7075-01 . . . . .
p.26
p.26
p.26
p.26
3000 or later ...Multi meters, Current /Insulation /Earth /Rotation /Thermo /Illumination /Power meters
3008. . . . . . .
3030-10 . . . . .
3118-11, -12 . .
3120. . . . . . .
3126-01 . . . . .
3127-10 . . . . .
3128-10 . . . . .
3129-10 . . . . .
3144-20 . . . . .
3151. . . . . . .
3153. . . . . . .
3154. . . . . . .
3156. . . . . . .
3157-01 . . . . .
3158. . . . . . .
3159. . . . . . .
3169-20,-21 . .
3173. . . . . . .
3193. . . . . . .
3194. . . . . . .
3196. . . . . . .
3197. . . . . . .
p.47
p.54
p.47
p.50
p.47
p.45
p.45
p.53
p.56
p.53
p.23
p.24
p.25
p.25
p.24
p.23
p.36
p.24
p.40
p.35
p.37
p.38
3237. . . . . . .
3238. . . . . . .
3239. . . . . . .
3244. . . . . . .
3245. . . . . . .
3246. . . . . . .
3255-50 . . . . .
3256-50,-51 . .
3257-50,-51 . .
3269. . . . . . .
3270. . . . . . .
3272. . . . . . .
3273-50 . . . . .
3274. . . . . . .
3275. . . . . . .
3276. . . . . . .
3280-10 . . . . .
3280-20 . . . . .
3281. . . . . . .
3282. . . . . . .
3283. . . . . . .
3284. . . . . . .
p.21
p.21
p.21
p.49
p.47
p.49
p.50
p.50
p.50
p.32
p.31
p.32
p.32
p.32
p.32
p.32
p.43
p.43
p.44
p.44
p.44
p.44
3285. . . . . . .
3285-20 . . . . .
3286-20 . . . . .
3287. . . . . . .
3288. . . . . . .
3290. . . . . . .
3290-10 . . . . .
3291. . . . . . .
3293. . . . . . .
3331. . . . . . .
3332. . . . . . .
3333,-01 . . . .
3403. . . . . . .
3404. . . . . . .
3412-50 . . . . .
3415-01 . . . . .
3416-01 . . . . .
3418. . . . . . .
3423. . . . . . .
3441. . . . . . .
3442. . . . . . .
3443. . . . . . .
p.44
p.44
p.46
p.43
p.43
p.45
p.45
p.45
p.45
p.35
p.40
p.40
p.53
p.53
p.27
p.27
p.27
p.27
p.30
p.30
p.30
p.30
3444. . . . . . .
3445. . . . . . .
3446-01 . . . . .
3447-01 . . . . .
3480-21 . . . . .
3451-11 to -15 . .
3452-11 to -13 . .
3453. . . . . . .
3454-10 . . . .
3454-11,-51 . .
3455. . . . . . .
3460-50 . . . .
3470. . . . . . .
3471. . . . . . .
3472. . . . . . .
3501. . . . . . .
3504/3504-10 .
3505/3506 . . .
3511-50 . . . . .
3522-50 . . . . .
3532-50 . . . . .
3535. . . . . . .
p.30
p.30
p.27
p.27
p.50
p.52
p.52
p.51
p.52
p.52
p.51
p.30
p.56
p.56
p.56
p.16
p.19
p.19
p.19
p.20
p.20
p.19
3540. . . . . . .
3540-01,-02,-03 .
3541. . . . . . .
3554. . . . . . .
3555. . . . . . .
3560. . . . . . .
3561. . . . . . .
3632-20 . . . . .
3633-20 . . . . .
3634-20 . . . . .
3635-24,-25,-26 .
3636-20 . . . . .
3637-20 . . . . .
3638-20 . . . . .
3639-20 . . . . .
3640-20 . . . . .
3641-20 . . . . .
3645-20 . . . . .
3661-20 . . . . .
3662-20 . . . . .
3663-20 . . . . .
3664. . . . . . .
p.17
p.17
p.17
p.54
p.54
p.18
p.18
p.29
p.29
p.29
p.29
p.29
p.29
p.29
p.29
p.29
p.29
p.29
p.55
p.55
p.55
p.56
3665-20 . . . . . p.55
3801-50 . . . . . p.49
3802-50 . . . . . p.47
3803. . . . . . . p.49
3804. . . . . . . p.47
3805. . . . . . . p.47
3851-10 . . . . . p.59
3852. . . . . . . p.63
3853. . . . . . . p.63
3854. . . . . . . p.63
3909. . . . . . . p.63
3911-20 . . . . . p.29
3912-20 . . . . . p.29
3930. . . . . . . p.23
SM-8200 . . . . .p.22
DSM-8104 . . . .p.22
DSM-8542 . . . .p.22
8000 or later ...Recorders and Peripherals
8205-10 . . . . . p.15
8206-10 . . . . . p.15
8420-51 . . . . . p.14
8421-51 . . . . . p.14
8422-51 . . . . . p.14
8715-01 . . . . . . p.4
8730-10 . . . . . p.13
8731-10 . . . . . p.13
8807-01 . . . . . p.12
8808-01 . . . . . p.12
8807-51 . . . . . p.12
8808-51 . . . . . p.12
8826. . . . . . . . p.8
8835-01 . . . . . . p.8
8841. . . . . . . . p.8
8842. . . . . . . . p.8
8855. . . . . . . .p.11
8860. . . . . . . . p.5
8861. . . . . . . . p.5
8936. . . . . . . . p.9
8937. . . . . . . . p.9
8938. . . . . . . . p.9
8939. . . . . . . . p.9
8940. . . . . . . . p.9
8946. . . . . . . . p.9
8947. . . . . . . . p.9
8950. . . . . . . .p.11
8951. . . . . . . .p.11
8952. . . . . . . .p.11
8953-10 . . . . . .p.11
8954. . . . . . . .p.11
8955. . . . . . . .p.11
8956. . . . . . . . p.6
8957. . . . . . . . p.6
8958. . . . . . . . p.6
8959. . . . . . . . p.6
8960. . . . . . . . p.6
8992. . . . . p.12,14
8993. . . . . . . p.14
8994. . . . . . . .p.11
8995,-01 . . . . . p.5
INR-9000 . . . . .p.15
9320-01 . . . . . p.10
9321. . . . . . . p.10
9321-01 . . . . . p.10
9322. . . . . . . p.10
9323. . . . . . . p.63
9324. . . . . . . p.10
9325. . . . . . . p.10
9326. . . . . . . p.60
9327. . . . . . . .p.11
9328. . . . . . . .p.11
9334. . . . . . . p.13
9335. . . . . . . . p.7
9338-9340 . . p.63
9344-9349 . . p.63
9351. . . . . . . p.63
9355. . . . . . . p.63
9360. . . . . . . p.63
9363. . . . . . . p.63
9371. . . . . . . p.63
9372. . . . . . . p.63
9375. . . . . . . p.63
9376. . . . . . . p.63
9377. . . . . . . p.63
9378. . . . . . . p.63
9380. . . . . . . p.63
9382. . . . . . . p.63
9384. . . . . . . p.63
9386. . . . . . . p.63
9388. . . . . . . p.63
9390. . . . . . . p.63
9391. . . . . . . p.63
9392. . . . . . . p.63
9393. . . . . . . p.63
9397. . . . . . . p.63
9398. . . . . . . p.63
9399. . . . . . . p.63
9418-10,-15 . . p.63
9420. . . . . . . p.63
9425. . . . . . . p.64
9433. . . . . . . p.64
9436. . . . . . . p.64
9438. . . . . . . p.60
9439. . . . . . . p.64
9440. . . . . . . p.64
9441. . . . . . . p.64
9442. . . . . . . p.64
9443-02, -03 . . p.64
9444. . . . . . . p.64
9445-02, -03 . . p.64
9446. . . . . . . p.64
9447. . . . . . . p.64
9451. . . . . . . p.64
9452. . . . . . . p.60
9453. . . . . . . p.60
9454. . . . . . . p.60
9455. . . . . . . p.60
9458. . . . . . . p.37
9459. . . . . . . p.37
9460. . . . . . . p.60
9461. . . . . . . p.60
9462. . . . . . . p.64
9465, -10 . . . . p.54
9466. . . . . . . p.60
9467. . . . . . . p.60
9472-9479 . . p.62
9517. . . . . . . p.64
9518-01 . . . . . p.20
9540-01 . . . . . p.64
9549. . . . . . . .p.11
9555. . . . . . . p.33
9557. . . . . . . p.64
9558. . . . . . . p.64
9588. . . . . . . p.64
9593-01 . . . . . p.20
9598. . . . . . . p.64
9599. . . . . . . p.64
9600. . . . . . . p.40
9601. . . . . . . p.40
9602. . . . . . . p.40
9603. . . . . . . p.40
9604. . . . . . . p.40
9605. . . . . . . p.40
9612. . . . . p.12, 14
9613. . . . . . . p.64
9614. . . . . . . p.64
9615. . . . . . . p.60
9617. . . . . . . p.60
9618. . . . . . . p.60
9624-50 . . . . . p.39
9625. . . . . . . p.36
9631. . . . . . . p.64
9632. . . . . . . p.64
9633. . . . . . . p.64
9634. . . . . . . p.64
9635-9636 . . p.46
9637-9638 . . p.64
9639. . . . . . . p.60
9641. . . . . . . p.14
9642. . . . . . . p.14
9643. . . . . . . p.14
9645. . . . . . . .p.11
9645-01 . . . . . .p.11
9646. . . . . . . .p.11
9648. . . . . . . p.14
9649. . . . . . . p.14
9650. . . . . . . p.34
9651. . . . . . . p.34
9652-01 . . . . . p.14
9657. . . . . . . p.34
9657-10 . . . . . p.34
9658. . . . . . . p.34
9660-9661 . . p.34
9667. . . . . . . p.34
9668. . . . . . . p.34
9669. . . . . . . p.34
9663. . . . . . . .p.11
9670. . . . . . . p.37
9671. . . . . . . p.37
9672, -10 . . . . p.33
9675. . . . . . . p.34
9677. . . . . . . p.19
9678. . . . . . . p.19
9680. . . . . . . p.64
9686. . . . . . . p.64
9694. . . . . . . p.34
9695. . . . . . . p.34
9699. . . . . . . p.19
9700-10 . . . . . p.19
9709. . . . . . . p.33
9713. . . . . . . p.64
9714. . . . . . . p.64
9720. . . . . . . p.64
9725. . . . . . . . p.7
9726. . . . . . . p.64
9727. . . . . . . p.64
9728. . . . . . . p.64
9729. . . . . . . p.64
9770. . . . . . . p.60
9771. . . . . . . p.60
9772. . . . . . . p.54
ALLIGATOR CLIPs . . p.60
CT-101A . . . . p.41
CT-2MR . . . . p.58
CT-5MRN . . . p.58
HB-1 . . . . . . p.58
HS-1 . . . . . . p.58
HS-2 . . . . . . p.58
220H . . . . . . p.10
SEM8301 . . . p.61
SEM8302 . . . p.61
SEM8310 . . . p.61
SEM8311 . . . p.61
SEM8330 . . . p.61
SEM8335 . . . p.61
SEM8350 . . . p.61
SEM8360 . . . p.61
SR-2. . . . . . . p.61
9000 or later ...Peripherals
9010. . . . . . .
9010-10, -50 . .
9014. . . . . . .
9017. . . . . . .
9018,-10, -50 .
9021-01 . . . . .
9032. . . . . . .
9033. . . . . . .
9050. . . . . . .
9060. . . . . . .
9067. . . . . . .
9081. . . . . . .
9084. . . . . . .
9094. . . . . . .
9132-10 . . . . .
9140. . . . . . .
9143. . . . . . .
9148. . . . . . .
9151-02 . . . . .
9151-04 . . . . .
9165/66 . . . .
9168. . . . . . .
9170. . . . . . .
9177. . . . . . .
9179. . . . . . .
9180 to 83 . .
9184. . . . . . .
9185. . . . . . .
9190. . . . . . .
9195. . . . . . .
9196. . . . . . .
9197. . . . . . .
9198. . . . . . .
9199. . . . . . .
9203. . . . . . .
9207-10 . . . . .
9208. . . . . . .
9209. . . . . . .
9211. . . . . . .
9212. . . . . . .
9213. . . . . . .
9214. . . . . . .
9215. . . . . . .
3
p.33
p.33
p.59
p.59
p.33
p.59
p.63
p.63
p.63
p.59
p.59
p.63
p.63
p.59
p.31
p.59
p.59
p.63
p.63
p.63
p.59
p.59
p.59
p.59
p.59
p.62
p.62
p.59
p.59
p.59
p.59
p.10
p.10
p.10
p.63
p.59
p.59
p.43
p.63
p.63
p.63
p.53
p.53
9216. . . . . . .
9217. . . . . . .
9221. . . . . . .
9222. . . . . . .
9223. . . . . . .
9229. . . . . . .
9229-01 . . . . .
9231. . . . . . .
9232. . . . . . .
9233. . . . . . .
9234. . . . . . .
9235. . . . . . .
9236. . . . . . .
9237. . . . . . .
9257. . . . . . .
9261. . . . . . .
9262. . . . . . .
9263. . . . . . .
9267. . . . . . .
9268. . . . . . .
9269. . . . . . .
9270. . . . . . .
9271. . . . . . .
9272. . . . . . .
9274. . . . . . .
9276. . . . . . .
9277. . . . . . .
9278. . . . . . .
9279. . . . . . .
9287-10 . . . . .
9288. . . . . . .
9290-10 . . . . .
9292. . . . . . .
9293. . . . . . .
9294. . . . . . .
9296. . . . . . .
9297. . . . . . .
9299. . . . . . .
9303. . . . . . .
9305. . . . . . .
9318. . . . . . .
9319. . . . . . .
9320. . . . . . .
p.63
p.59
p.62
p.63
p.62
p.62
p.62
p.62
p.62
p.62
p.62
p.62
p.62
p.62
p.59
p.59
p.59
p.59
p.23
p.59
p.59
p.31
p.31
p.31
p.31
p.31
p.33
p.33
p.33
p.60
p.60
p.31
p.60
p.60
p.60
p.60
p.60
p.60
p.10
p.63
p.63
p.63
p.10
Recorders, Memory Recorders
Recorders, Memory Recorders Index
Handy units for ser vice and maintenance recording
400 kS/sec.(2 ch)
256 kW (1 ch) memory
12 bits A/D resolution
Battery operation
. . . . . . . . . . . . . . . p.12
8808-01
400 kS/sec.(4 ch)
256 kW (1 ch) memory
12 bits A/D resolution
Battery operation
. . . . . . . . . . . . . . . p.12
8835-01
1 MS/sec.(8 ch)
4 MW (1 ch) memory
12 bits A/D resolution
. . . . . . . . . . . . . . . . p.8
8205-10
Recorder (1ch)
100 sampling/sec.
No memory
. . . . . . . . . . . . . . . p.15
8420-51/8421-51
Data logger (8 ch,16 ch)
100 ms to 1h interval
16 MW internal memory
16 bits A/D resolution
Battery operation
. . . . . . . . . . . . . . . p.14
8422-51
Data logger (32 ch)
100 ms to 1h interval
16 MW internal memory
16 bits A/D resolution
Battery operation
. . . . . . . . . . . . . . . p.14
For simultaneous recording of multiple signals WAVE
COMPARATOR
8860
20 MS/sec. (12 bits 8 ch)
2 MS/sec. (16 bits 8 ch)
50 ms/all ch (16 bits 64 ch)
32 MW up to 1GW memory
. . . . . . . . . . . . . . . . p.5
8861
20 MS/sec. (12 bits 16 ch)
2 MS/sec. (16 bits 16 ch)
50 ms/all ch (16 bits 128 ch)
64 MW up to 2GW memory
. . . . . . . . . . . . . . . . p.5
For waveform capture
of high-speed signals
8841
1 MS/sec. (8/16 ch)
4 MW (1 ch) memory
(expandable up to four)
12 bits A/D resolution
. . . . . . . . . . . . . . . . p.8
8842
1 MS/sec. (16 ch)
4 MW (1 ch) memory
(expandable up to four)
12 bits A/D resolution
. . . . . . . . . . . . . . . . p.8
8826
1 MS/sec. (32 ch)
4 MW (1 ch) memory
(expandable up to four)
12 bits A/D resolution
. . . . . . . . . . . . . . . . p.8
Recorders, Memory Recorders
8807-01
8730-10/8731-10
Geared for the
Production line
8730-10: 1ch input
8731-10: 2ch input
. . . . . . . . . . . . . . . p.13
Options for MEMORY HiCORDER series
8855
8 channels
20 MS/sec.(8 ch)
Max. 512 MW memory
12 bits A/D resolution
(16 bits A/D 1 MS/sec.)
. . . . . . . . . . . . . . . p.11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.5,6,7,9,10
For power line fault monitoring
8206-10
Recorder for power lines
100 sampling/sec.(2 ch)
AC voltage and current
No memory
. . . . . . . . . . . . . . . p.15
8715-01
Recorder for power lines
400 kS/sec.(4 ch)
64 kW/ch memory
12 bits A/D resolution
Battery operation
8807-51
Harmonic analysis
400 kS/sec (2 ch)
256 kW (1 ch)Memory
12 bits A/D resolution
. . . . . . . . . . . . . . . p.12
8808-51
Harmonic analysis
400 kS/sec (4 ch)
256 kW (1 ch)Memory
12 bits A/D resolution
. . . . . . . . . . . . . . . p.12
INTELLIGENT RECORDER
JULIUS
INR-9000 series
INR-9011(1pen)9121(12pen)
Infomedia inclusive of chart,
LCD, MO, FD & MC, multirecording, monitoring, data
storage & processing available
. . . . . . . . . . . . p.15
4
MEMORY HiCORDER
8860 8861
HIOKI's Next Generation Recorder
High Performance Isolated Oscilloscope and Data Logger
All in One Complete Instrument
●High and Low Speed Dual Sampling - High speed at 20MS/s
(with 8956 input unit)
●Maximum 128 channels (8861) or 64 channels (8860) of data logging
●Large capacity memory, LAN/USB and other popular PC interfaces standard
●Intuitive operation using GUI/mouse/keyboard
STANDARD
STANDARD
Recorders, Memory Recorders
8861
8860
SPECIFICATIONS
Measurement ranges 5 mV to 20 V/division, 12 ranges (20 divisions f.s.),
using 8956 ANALOG UNIT /option resolution: 1/100 of range
DC to 10 MHz ±3 dB (using 8956 ANALOG UNIT /option)
Frequency band
Time axis
at memory function
Measurement
functions
5μs to 5 minutes/division, 25 settings;
external sampling (100 samples/division, desired setting)
Memory, Recorder,
Recorder & Memory(Version 2.00 or later),
FFT, Real-time save function
8860:Analog (up to 8 channels) + logic (16 channels standard)
Number of
or Logger Input (up to 64 channels)
input channels
8861:Analog (up to 16 channels) + logic (16 channels standard)
or Logger Input (up to 128 channels)
8860: 32 M words/9715×1 (Total 1 GW, 9715-03 (×1))
Memory capacity
8861: 64 M words/9715×2 (Total 2 GW, 9715-03 (×2))
Type II PC card slot, MO drive (optional), Hard disk drive
Data storage
(optional)
USB1.1, LAN, GP-IB (with GP-IB CARD 9558), Monitor output
Interfaces
(SVGA), PS/2 socket (for mouse and keyboard)
Recording and display 10.4-inch TFT color LCD, 216 mm × 30 m (A4) or 112 mm ×
18m (A6), thermal paper roll
Scaling, Vernier function, cursor measurement, comment
Other functions
insertion, other functions
100 to 240 V AC (50/60 Hz)
Power supply
Dimensions, mass 8860: 330 mmW×250 mmH×184.5 mmD, 8.0 kg
8861: 330 mmW×250 mmH×284.5 mmD, 10.5 kg
(base unit only)
Power cord (1), input cord label (1), Wave viewer software (1)
Accessories
OPTIONS
(The 8860 or 8861 cannot be used alone. Measurement requires optional input unit or similar peripheral.)
●Options (Factory fitted)
A4 PRINTER UNIT
8995
A6 PRINTER UNIT
8995-01
MEMORY BOARD(32MW to 1GW)* 9715,-01,-02,-03
●Options
CONNECTION CORD (500V Max.)
CONNECTION CORD (300V Max.)
CONNECTION CORD (BNC-BNC)
RECORDING PAPER
(for A4-printer 8995 only)
A4 width 216 mm × 30 m, 6 rolls
RECORDING PAPER
(for A6-printer 8995-01 only)
A6 width 112 mm × 18 m, 10 rolls
DIFFERENTIAL PROBE
LOGIC PROBE
MEMORY BOARD
9715
8860
8956
8957
8958
8959
8936
8937
8938
8939
8940
8946
8947
8960
8861
5
9234
9322
9327
HD UNIT
9718
*One MEMORY BOARD is required in Model 8860, and two MEMORY BOARDs
of the same capacity are required in Model 8861
Input modules
ANALOG UNIT (20MS/s)
HIGH RESOLUTION UNIT
16ch SCANNER UNIT
DC/RMS UNIT
ANALOG UNIT (1MS/s)
VOLTAGE/TEMP UNIT
FFT ANALOG UNIT
STRAIN UNIT (12Bit)
F/V UNIT
4ch ANALOG UNIT
CHARGE UNIT
STRAIN UNIT (16Bit)
9197
9198
9217
9231
MO UNIT
HD UNIT
MEMORY BACK UP UNIT
9717
9718
9719
LOGIC PROBE
9320-01
LOGIC PROBE
9321-01
CARRYING CASE (for 8860)
9723
CARRYING CASE (for 8861)
9724
MEMORY HiVIEWER
9725
LAN CABLE
9642
PC CARD 128MB
9726
PC CARD 256MB
9727
PC CARD 512MB
9728
PC CARD 1GB
9729
CLAMP ON SENSORs (refer to p.31-34)
Other common options (refer to p.10)
MO UNIT
9717
INPUT Units
For 8860, 8861 only
Dimensions and mass: approx.
170W × 20H × 148.5D mm, approx. 290g
Accessories: None
Dimensions and mass: approx.
8956
170W × 20H × 148.5D mm, approx. 310 g
Accessories: None
Measurement range
Measurement
resolution
Highest sampling
rate
8957
HIGH-RESOLUTION UNIT 8957
Measurement functions Number of channels: 2, for voltage measurement
Isolated BNC connector (input impedance 1 MΩ, input capacitance 40
pF), Max. rated voltage to earth: 300 V AC, DC (with input isolated
Input connectors
from the unit, the maximum voltage that can be applied between input
channel and chassis and between input channels without damage)
5 mV to 20 V/division, 12 ranges, full scale: 20 divisions, AC
Measurement range voltage for possible measurement/display using the memory
function: 280 V rms, low-pass filter: 5/50/500/5k/50k Hz
Integrated filter for suppressing aliasing distortion caused by
Anti-aliasing filter
FFT processing (automatic cutoff frequency setting/OFF)
1/1600 of measurement range (using 16-bit A/D conversion;
Measurement resolution
installed in 8860/8861)
2 MS/s (simultaneous sampling in 2 channels)
Highest sampling rate
DC amplitude: ±0.2% of full scale (with filter 5 Hz)
Accuracy
Zero position: ±0.1% of full scale (with filter 5 Hz, after zero adjustment)
Frequency characteristics DC to 200 kHz ±3 dB, with AC coupling: 7 Hz to 200 kHz ±3 dB
DC, GND, AC
Input coupling
400 V DC (the maximum voltage that can be applied across
Max. allowable input
input pins without damage)
8958
16ch SCANNER UNIT 8958
Number of channels: 16, for voltage measurement/temperature
Measurement
measurement with thermocouple
functions
Voltage input/Thermocouple input: screw-type terminal strip, recommended wire diameter
*1, detachable terminal block (with cover) *1 Recommended cable, single-wire: 0.14 to 1.5
mm2, braided wire 0.14 to 1.0 mm2 (conductor wire diameter min. 0.18 mm), AWG 26 to 16
Input connectors
Input impedance: 1 MΩ, 850 kΩ with line fault detection ON, Max. rated voltage to earth:
33 Vrms or 70 V DC (with input isolated from the unit, the maximum voltage that can be
applied between input channel and chassis and between input channels without damage)
5m, 50m, 500m, 2 V/division, 4 ranges, full scale: 20 divisions,
measurement range: ±100% of full scale, digital filter: 10/50/60
Voltage
measurement range Hz, measurement resolution 1/1600 of measurement range
(using 16-bit A/D conversion; installed in 8860/8861)
Temperature
10°C/division (-100°C/ to +200°C), 50°C/division (-200°C/ to +1000
measurement range
°C), 100°C/division (-200°C/ to +2000°C), 3 ranges, full scale: 20
(Upper and lower limit values divisions, digital filter: 10/50/60 Hz, measurement resolution 1/1000 of
depend on measurement
measurement range (using 16-bit A/D conversion; installed in 8860/8861)
input range of sensor)
Thermocouple
range
(JIS C 1602-1995)
(ASTM E-988-96)
K: -200 to 1350°C, J: -200 to 1200°C, E: -200 to 1000°C, T: -200 to
400°C, N: -200 to 1300°C, R: 0 to 1700°C, S: 0 to 1700°C, B: 400 to
1800°C, W (WRe5-26): 0 to 2000°C, reference junction compensation:
internal/ external (switchable), line fault detection ON/OFF switchable
Data refresh rate
50 ms/all channels (digital filter OFF), 300 ms/all channels
(digital filter 50/60 Hz), 1.4 s/all channels (digital filter 10 Hz)
Accuracy
Max. allowable
input
1/80 of measurement range (using 12-bit A/D conversion;
installed in 8860/8861)
1 MS/s (simultaneous sampling in 2 channels)
Frequency
characteristics
Input coupling
DC, GND, AC
Max. allowable
input
400 V DC (the maximum voltage that can be applied across
input pins without damage)
Dimensions and mass: approx.
170W × 20H × 148.5D mm, approx. 290 g
Accessories: Conversion cable × 2, cable length 50cm
8960
STRAIN UNIT 8960
Number of channels: 2, for distortion measurement (electronic
Measurement
auto-balancing, balance adjustment range within ±10000 µε)
functions
Via conversion cable, TAJIMI PRC03-12A10-7M10.5, Max.
rated voltage to earth: 33 Vrms or 70 V DC (with input isolated
from the unit, the maximum voltage that can be applied between
Input connectors
input channel and chassis and between input channels without
damage)
Strain gauge converter, bridge impedance: 120 Ω to 1 kΩ
Suitable transducer (bridge voltage 2 V), 350 Ω to 1 kΩ (bridge voltage 5 V, 10 V),
bridge voltage 2, 5, 10 ±0.05 V
Measurement range
20 με to 1000 με/division, 6 ranges, full scale: 20 divisions,
low-pass filter: 5/10/100/1k Hz
Anti-aliasing filter
Integrated filter for suppressing aliasing distortion caused by
FFT processing (automatic cutoff frequency setting/OFF)
Dimensions and mass: approx.
170W × 20H × 183D mm, approx. 385 g
Accessories: Flathead screwdriver × 1, short bar × 2
5 mV to 20 V/division, 12 ranges, full scale: 20 divisions, AC
voltage for possible measurement/display using the memory
function: 280V rms, low-pass filter: 5/500/5k/100k Hz
DC amplitude: ±0.4% of full scale (with filter 5 Hz), zero
position: ±0.1% of full scale (with filter 5 Hz, after zero
adjustment)
RMS amplitude accuracy: ±1% of full scale (DC, 20 Hz to 1
kHz), ±3% of full scale (1 kHz to 100 kHz), response time:
SLOW 5 s (rise time from 0 to 90% of full scale), MID 800 ms
(rise time from 0 to 90% of full scale), FAST 100 ms (rise time
from 0 to 90% of full scale), crest factor: 2
DC to 400 kHz ±3 dB, with AC coupling: 7 Hz to 400 kHz ±3
dB
Accuracy
RMS measurement
Dimensions and mass: approx.
8959
DC/RMS UNIT 8959
Measurement
Number of channels: 2, for voltage measurement
functions
Isolated BNC connector (input impedance 1 MΩ, input
capacitance 30 pF), Max. rated voltage to earth: 370 V AC, DC
(with input isolated from the unit, the maximum voltage that
Input connectors
can be applied between input channel and chassis and between
input channels without damage)
Recorders, Memory Recorders
ANALOG UNIT 8956
Number of channels: 2, for voltage measurement
Measurement functions
Isolated BNC connector (input impedance 1 MΩ, input capacitance 40
pF), Max. rated voltage to earth: 300 V AC, DC (with input isolated
Input connectors
from the unit, the maximum voltage that can be applied between input
channel and chassis and between input channels without damage)
5 mV to 20 V/division, 12 ranges, full scale: 20 divisions, AC
Measurement range voltage for possible measurement/display using the memory
function: 280 V rms, low-pass filter: 5/500/5k/1M Hz
1/100 of measurement range (using 12-bit A/D conversion;
Measurement resolution
installed in 8860/8861)
20 MS/s (simultaneous sampling in 2 channels)
Highest sampling rate
DC amplitude: ±0.4% of full scale (with filter 5 Hz)
Accuracy
Zero position: ±0.1% of full scale (with filter 5 Hz, after zero adjustment)
DC to 10 MHz ±3 dB, with AC coupling: 7 Hz to 10 MHz ±3 dB
Frequency characteristics
DC, GND, AC
Input coupling
400 V DC (the maximum voltage that can be applied across
Max. allowable input
input pins without damage)
170W × 20H × 148.5D mm, approx. 290 g
Accessories: None
Measurement
resolution
Highest sampling
rate
1/1600 of measurement range (using 16-bit A/D conversion;
installed in 8860/8861)
Accuracy After
auto-balancing
DC amplitude: ±(0.4% of full scale +2 με), zero position: ±
(0.1% of full scale +2 με) (at 5 Hz filter ON)
Frequency
characteristics
Max. allowable
input
200 kS/s (2-channel simultaneous sampling)
DC to 20 kHz +1/-3 dB
10 V DC (the maximum voltage that can be applied across input
pins without damage)
* Available from main unit 8860/8861 version 1.06
INPUT Units
For 8826, 8835-01, 8841, 8842, 8860, 8861(refer to p-9)
8936
ANALOG UNIT
8937
VOLTAGE/TEMPERATURE UNIT
8938
FFT ANALOG UNIT
8939
STRAIN UNIT
8940
F/V UNIT
8946
4ch ANALOG UNIT
8947
CHARGE UNIT
Voltage: ±0.2% of full scale, thermocouple (K, J, E, T, N): ±0.05% of full scale
±1°C, (R, S, B, W): ±0.05% of full scale ±2°C (400°C or more), ±0.05% of full
scale ±3.5°C (less than 400°C), reference junction compensation accuracy: ±1°C
(added to measurement accuracy with internal reference junction compensation)
40 V DC (the maximum voltage that can be applied across input
pins without damage)
6
MEMORY HiVIEWER (for 8860,8861)
Perform 8860 and 8861 functions on your PC
●Application software enables you to perform the same data analysis
on a Windows computer as on the 8860 and 8861 MEMORY
HiCORDERs.
●No confusion, because the screens appearing on the computer are
identical to those of the 8860/8861.
●Functions identical to those of the 8860/8861, such as waveform
processing calculation, run on the computer.
Recorders, Memory Recorders
WAVE PROCESSOR
MEMORY HiCORDER; 8807 (-01/-51), 8808 (-01/-51), 8826,
8835 (-01), 8841, 8842, 8855, 8860,8861 (2 time axis impossible)
Compatible devices POWER HiCORDERs 8714 (-01), 8715 (-01);
VISUAL HiCORDER; 8720
WAVE COMPARATOR; 8730-10, 8731-10
3.5"FD
Supplied Media
One CD-R disc
Operating environment
Computers running Windows 95, 98, Me, NT4.0, 2000 or XP
Pentium (133MHz) or better, at least 32MB of memory
(Recommended: Pentium (200MHz) or better, at least 64MB of memory)
Ethernet
MEMORY HiCORDER
8855
FTP
9335
SPECIFICATIONS
PC Card
3.5"MO
SPECIFICATIONS
Compatible devices MEMORY HiCORDER 8860, 8861
One CD-R disc
Supplied Media
Operating environment Computer running under Windows 2000/XP
Readable data formats : Only for 8860, 8861 data (.MEM,
.REC, .SEQ, .IDX, .SET)
File loading
Maximum file size : 2 GW
Saved contents: measurement data (binary and ASCII), (partial
saving of the area between cursors A and B), setting conditions,
File saving
screen image (BMP, PNG), and calculation results
■Waveform display: 1-, 2-, 3-, 4-, 6-, and 8-split screen, horizontal, vertical,
consecutive scroll, and zoom in/out along the time axis, move the zero
position, zoom in/out, setting of variables independently for each channel
■X-Y-axis composite display (for the MEM function only): 1-, 2-, and 4-split
display, dot/line interpolation, composite area can be specified
■Numerical display: digital values of waveform data can be displayed
Display
■Display sheet: 16 sheets
■Display channel count (per sheet): 32 analog channels, 16 logic channels,
16 calculated waveforms, 8 X-Y-axis composite waveforms
■Cursor function: vertical cursor, horizontal cursor, trace cursor, two
cursors (cursor A and cursor B), time and voltage display
■Clipboard copy: images on the waveform screen can be transferred to the
clipboard
■Supported printer: printer compatible with the OS
■Print format: waveform image (1-, 2-, 3-, 4-, 6-, 8-, and 16-split),
numerical print, report format, list print, calculation results, screen image
Print
■Print area: the entire area, area between cursors A and B
■Print preview
(for MEMORY HiCORDER)
Display, Convert, Calculate and Print Waveforms on a PC
9725
PC
*Note: The use of MO discs, PC cards, and floppy disks and the availability of a LAN
connection depend on the specifications of the recorder model in question.
Display functions
File loading
Data conversion
functions
Printing functions
■Waveform Display: Displays image of loaded waveform data on
screen ■X-Y display: Memory function format (.MEM file) only
■Digital Value Display: Displays waveform data as digital values,
and allows images and digital values to be displayed
simultaneously ■Cursor function: Allows you to display the time
and potential differences between cursors A and B, the time and
electrical potential between each cursor, and the absolute and
relative times ■Scroll function: available ■Maximum number of
channels: 32 analog channels, 32 logic channels ■Gauge display:
Time gauge, voltage axis gauge ■Graphical input: Possible
■Loading data format: Memory (.MEM, except for data stored in
real time); recorder (.REC), effective value recorder (.RMS)
■Maximum loadable file size: Maximum size that can be stored by
hardware. The maximum size that can be handled may be smaller
in some PC environments.)
■Target data: All data, data between cursors ■Data interval: Simple
interval (number of samples can be specified) ■Data conversion:
Converts analog waveform data into numeric values, converts
logic data into binary ■Data conversion format: CSV format, tab
delimited, space delimited (selectable when data is saved)
■Conversion channel: Can be selected when data is saved ■Batch
conversion: Multiple files can be specified for batch conversion
■Printing format: Can print no partitions, 2 to 16 partitions, 2 to 16
columns, X-Y 1 to 4 partitions, gauges, channel comments ■Print
preview: Possible ■Waveform screen hard copy: ■Possible
Compatible printers: Any printer supported by the OS (color or
black and white)
■Target data: All data, data between cursors ■Calculation items:
Average value, effective value, peak value, maximum value, time
Parameter
of maximum value, minimum value, time of minimum value, rise
calculation functions
time, fall time, standard deviation, area, cycle, frequency, pulse
width, duty ratio, ON time, OFF time, number of times turned ON
Other
7
■Search functions: Event mark, date and time (absolute time, time
relative to trigger), maximum, minimum, absolute maximum,
absolute minimum, level up/down, window in/out Clipboard copy:
Waveform screen, cursor value, digital value, file information
■Startup of other applications: Other applications can be launched
by specifying run file
MEMORY HiCORDER
High-visibility, Compact, Multi-channeled
Field measurement has never been easier
8835-01
●Compact 4/8 ch recorder saves space with slim profile
●110mm-width recording paper and a large color display(6.4-inch)
●Maximum 8 analog channels and 16 logic
●Network Recording Instrument for LAN
OPTION
OPTION
MEMORY HiCORDER
Mainstream recorder with 16 fully isolated
channels
8841 8ch (16ch)
OPTION
OPTION
MEMORY HiCORDER
●Simultaneous sampling, display and recording of all 32 analog and 32
logic channels
●Large capacity memory of max. 16M-word
Memory expandable four times (option)
●High resolution of 12-bit, 1 M-sampling /second
●B4-size (paper width 264 mm) wide printer
●High-visibility waveforms displayed on a 10.4-inch color TFT liquid
crystal display
OPTION
STANDARD
OPTION
5 mV to 20 V/division, 12 ranges (20 division f.s.)
resolution: 1/80 of range
DC to 400 kHz , ±3dB
100µs to 5 minutes/division, 20 ranges (1division =100samples)
Memory recorder, Recorder (included X-Y), RMS recorder
(50/60 Hz or DC only), Recorder and Memory, FFT
Number of input channels 8-analog plus 16-logic channels :8841 (using 8936)
using 8936, 8946 ANALOG UNIT /option 16-analog plus 16-logic channels :8841 (using 8946)
16-analog plus 16-logic channels :8842 (using 8936)
Memory capacity
12 bits×4 M words*/channel (using 2 channels)
*Memory capacity can be expanded 4 times.
Data storage
FDD×1, Type-III PC card×1; SRAM, flash ATA, hard-disk card
Interfaces
LAN, GP-IB, SCSI (for MO drive connection, standard),
RS-232C, external printer (option, use PC card)
Recording and display 216 mm×30 m, roll type thermal paper,
Recording speed: 25 mm/s, 10.4-inch color TFT LCD
Other functions
Scaling, Waveform parameter calculations,
Memory segmentation, Cursor readout, etc.
Power supply
100 to 240 V AC (50/60 Hz)
* 10 to 28 V DC, using DC POWER ADAPTER 9433
Dimensions, mass
280W×300H×140D mm, 6.0kg :8841
280W×300H×220D mm, 7.0kg :8842
Accessories
Power cord(1), Recording paper(1 roll), Dust cover(1),
PC card protector(1), Wave viewer software(1)
8826
32-channel recorder with all isolated inputs
OPTION
4 analog channels plus 16 logic channels (using 8936)
8 analog channels plus 16 logic channels (using 8946)
12bits×4M words/channel (using 1 channel)
FDD×1, Type-III PC card×1;
PC CARD 9726-9729
LAN, GP-IB, or RS-232C (option, using PC card)
Interfaces
Recording and display 110mm×30 m, roll type thermal paper,
Recording speed: 25mm/s, 6.4-inch color TFT LCD
Scaling, Waveform parameter calculations,
Other functions
Memory segmentation, Cursor readout, etc.
100 to 120V AC or 200 to 240V AC (50/60 Hz)
Power supply
* 10 to 28V DC, using the DC POWER ADAPTER 9439
285W×220H×132D mm, 4.5kg
Dimensions, mass
Power cord(1), Recording paper(1 roll), Dust cover(1),
Accessories
PC card protector(1), Wave viewer software(1)
SPECIFICATIONS
Measurement ranges
using 8936 ANALOG UNIT /option
Frequency band
Time axis at memory function
Functions
8842 (16ch)
STANDARD
Memory recorder, Recorder (included X-Y), RMS recorder
(50/60Hz or DC only), *Recorder and Memory, *FFT
8841 8842
●A4-width recording paper and a large color display(10.4-inch)
●Maximum 16 analog channels and 16 logic
●High performance and easy operation
●Network Recording Instrument for LAN
OPTION
10mV to 50V/division, 12 ranges (10 division f.s.)
resolution; 1/160 of range
DC to 400kHz , ±3dB
100µs to 5 minutes/division, 20 ranges (1division =100samples)
Recorders, Memory Recorders
OPTION
SPECIFICATIONS
Measurement ranges
using 8936 ANALOG UNIT /option
Frequency band
Time axis at memory function
Functions
*Additional functions, using 9540-01
FUNCTION UP DISK /option
Number of input channels
using 8936, 8946 ANALOG UNIT /option
Memory capacity
Data storage
SPECIFICATIONS
Measurement ranges
5 mV to 20 V/division, 12 ranges
(normal f.s.; 20 division, wide f.s.; 24 division),
resolution: 1/80 of range
Frequency band
DC to 400 kHz, ±3dB
Time axis at memory function 100µs to 5 minutes/division, 20 ranges
(1 division =100 samples)
Functions
Memory recorder, Recorder (included X-Y),
RMS recorder, Recorder and Memory, FFT
Number of input channels 32 analog channels plus 32 logic channels
Memory capacity
(analog 12 bits)×4M words/channel (using 4ch)
* Expandable up to four, using 9599 MEMORY BOARD
Data storage
FDD×1, Type-III PC card×1; SRAM, flash ATA,
PC CARD 9726-9729
Recording and display 264 mm×30 m, roll type thermal paper,
Recording speed: 25 mm/s, 10.4-inch color TFT LCD
Other functions
Scaling, Waveform judgment, Waveform processing
calculations, Waveform parameter calculations,
Memory segmentation, Logging print, Clock,
Cursor readout, Comment entry, etc.
Power supply
100 to 240 V AC, 50/60 Hz
Dimensions, mass
401W×235H×382D mm, 11 kg (excluding input units)
Accessories
Power cord(1), Recording paper(1 roll), Dust cover(1),
PC card protector(1), Wave viewer sofutware(1)
8
INPUT Units
For 8826, 8835-01, 8841, 8842, 8860, 8861
9318
Dimensions and mass:
Approx. 170W × 20H × 148D mm, approx. 290g
8936, 8938
ANALOG UNIT 8936
Input
Measurement range
Recorders, Memory Recorders
Maximum sampling rate
Accuracy
Zero-position
Frequency characteristics
Input resistance and capacitance
Input coupling
Max. allowable input
Max. grounding voltage
Accessories
Other functions
Accessories
Cutoff frequency 20, 40, 80, 200, 400, 800, 2k, 4k, 8k, 20k,
40kHz auto-select (linked to frequency range)
Same as the ANALOG UNIT 8936
None *Input cord optional
(to connect the 3273 to the 8940)
Dimensions and mass:
8940
F/V UNIT 8940
Number of channels: 2*1, Voltage input: BNC terminal
Input isolated from output, inter-channel isolation
Sensor connector terminal Number of channels: 2 (for current measurement)*2
*2 Models that allow unit insertion up to a total of 4 channels: 8841, 8842, 8720
Compatible current sensors 9270, 9271, 9272, 9277, 9278, 9279, 3273, 3273-50
Frequency: 0.05Hz to 5kHz/ division, 11 ranges, 5(r/min) to 500(r/min)/
Measurement range
division, 5 ranges, P50 Hz (40 to 60 Hz), P60 Hz (50 to 70 Hz)
Integration: 5 counts to 500 k counts/ division, Pulse duty ratio:
100 % f.s. Current: 5 mA to 100 A/ division, 10 ranges, linked to
use with type of the clamp-on sensor, Voltage: 0.5 mV to 2 V/
division, 12 ranges, Max. allowable input: 30 V rms or 60 V DC,
full-scale (f.s.) = 20 divisions, low-pass filter, 5/500/5k/ 100kHz
or OFF, the measurement resolution is 1/80*3 of range
*3 When used with 8841, 8842, and when used with CLAMP
ON SENSOR 9279, the resolution is 1/64 of range
Max. sampling period 1µs (voltage, current)
Voltage input pull-up: ON (10kΩ)/ OFF
Other functions
Input coupling: DC, GND, AC (voltage, current), DC (others)
Max. grounding voltage 30V rms or 60V DC (upper voltage which when applied to input
channel casing or between input channels does not damage them)
None * Input cord and conversion cable optional
Accessories
Input
*1
Dimensions and mass:
Approx. 170W × 20H × 148D mm, approx. 300g
8937
VOLTAGE/TEMPERATURE UNIT 8937
Number of channels: 2 each for voltage and temperature
* Input isolated from output, inter-channel isolation
Voltage input: isolated BNC, thermocouple input: plug-in terminal
Voltage measurement 500µV to 2V/ division; 12 settings, full-scale (f.s.) = 20 divisions,
low-pass filter: 5/500/5k/ 100kHz, the measurement resolution
range
is 1/80 of range * When used with 8841, 8842
10°C to 100°C/ division; 4 settings, full-scale (f.s.) = 20 divisions,
Temperature
low-pass filter: 5/ 500Hz, measurement resolution: 1/80 of range
measurement range
* When used with 8841, 8842
K: -200 to 1350°C, E: -200 to 800°C, J: -200 to 110°C,
Thermocouple range
T: -200 to 400°C, N: -200 to 1300°C, R: 0 to 1700°C,
S: 0 to 1700°C, B: 300 to 1800°C,
Reference junction compensation: internal/ external (switchable)
Voltage input: 1 MS/s, Temperature measurement: 4kS/s
Max. sampling rate
(2-channel simultaneous sampling)
Voltage input: DC amplitude ±0.4% of f.s. Zero-position ±0.15%
Accuracy
of f.s. Temperature measurement (K, E, J, T, N): ±0.1% of f.s.
±1°C, ±0.1% of f.s. ±2°C (-200 to 0°C), (R, S): ±0.1% of f.s.
±3°C, (B): ±0.1% of f.s. ±4°C (400 to 1800°C) Reference junction
compensation accuracy: ±0.1 % f.s. ±1.5°C (internal compensation)
Voltage input: -50% to 150%, 1% steps * With zero-adjust function
Zero position
Temperature measurement: -100% to 100%, 1% steps
Frequency characteristics Voltage input: DC to 400kHz + 1/-3dB
Temperature measurement: DC to 1 kHz + 1/-3dB
Voltage input: 1 MΩ, 50pF approx. (at C 100 kHz)
Input resistance and
Temperature measurement: 5.1MΩ
capacitance
DC, GND, AC
Input coupling
30V rms or 60V DC
Max. allowable input
(upper voltage which when applied to between input pins does not damage them)
Max. grounding voltage 30V rms or 60V DC (upper voltage which when applied to input
channel casing or between input channels does not damage them)
None * Input cord optional
Accessories
Dimensions and mass:
Approx. 170W × 20H × 148D mm, approx. 250g
8939
STRAIN UNIT 8939
Inputs
Converter connector
Suitable converter
Measurement range
Maximum sampling rate
Accuracy (after auto-balancing)
Balancing
Zero position
Frequency characteristics
Max. allowable input
Max. grounding voltage
Accessories
Dimensions and mass:
Approx. 170W × 20H × 148D mm, approx. 310g
8946
Inputs
9
CONVERSION CABLE 9319
Approx. 170W × 20H × 148D mm, approx. 300g
Number of channels: 2, Connector: Insulated BNC
* Input isolated from output, inter-channel isolation
5mV to 20V/ division, 12 ranges, full-scale (f.s.) = 20 divisions,
AC voltage for possible measurement/ display using the memory function
: 280V rms, Low-pass filter, 5/500/ 5k/ 100kHz, the measurement
resolution is 1/80 of range * When used with 8841, 8842
1 MS/s (simultaneous sampling of two channels)
DC amplitude: ±0.4%f.s. Zero-position: ±0.1%f.s.
-50% to 150%, 1 % step * With zero-adjustment function
DC to 400kHz ±3 dB, with AC coupling: 7Hz to 400kHz ±3dB
1MΩ, 30 pF approx. (at C 100kHz)
DC, GND, AC
400V DC (upper voltage which when applied to between input pins does not damage them)
370V AC, DC (upper voltage which when applied to input channel casing or
between input channels does not damage them)
None * Input cord optional
FFT ANALOG UNIT 8938
Anti-aliasing filter
CONVERSION CABLE 9318
(to connect the clamp-on sensor to the 8940)
9319
Number of channels: 2, Connector: Adapter cable connector
* Input isolated from output, inter-channel isolation
Via adapter cable, TAJIMI PRC03-32A10-7M10.5
Strain gage converter, bridge impedance: 120Ω to 1kΩ,
gage factor 2.00, bridge voltage 2 ±0.05 V
20µe to 1000µe/ division; 6 settings, full-scale (f.s.) =
20 divisions, low-pass filter: 10 Hz, 30 Hz, 300 Hz, 3 kHz, OFF
the measurement resolution is 1/80 of range *Using 8841, 8842, 8720
1 MS/s (simultaneous sampling for 2 channels)
DC amplitude: ±(0.5 %f.s. + 2µe) Zero-position: ±0.5 %f.s.
Electronic auto-balancing, max. adjustment range ±10000µe
-50 % to 150 %; in 1% steps * With auto-balancing
DC to 20 kHz +1/-3 dB
10 V (DC + AC peak) (upper voltage which when applied to
between input pins does not damage them)
30 V rms or 60 V DC (upper voltage which when applied to input
channel casing or between input channels does not damage them)
Conversion cable (2)
4ch ANALOG UNIT 8946
Inputs
Measurement range
Maximum sampling rate
Accuracy
Zero-position
Frequency characteristics
Input resistance and capacitance
Input coupling
Max. allowable input
Max. grounding voltage
Accessories
Number of channels: 4, Terminal: Metallic BNC
* Input isolated from output, inter-channel isolation
10 mV to 2 V/ division, 8 ranges, full-scale (f.s.) = 20 divisions,
low-pass filter, 5/ 500/ 5 k/ 50 kHz; the measurement resolution
is 1/80 of range * When used in 8841
1 MS/s (simultaneous sampling of four channels)
DC amplitude: ±0.5 % f.s. Zero-position: ±0.15 % f.s.
-50 % to 150 %, 1 % step * With zero-adjustment function
DC to 100 kHz ±3 dB
1 MΩ, 15 pF approx. (at C 100 kHz)
DC, GND
30 V rms or 60 V DC (upper voltage which when applied to
between input pins does not damage them)
30 V rms or 60 V DC (upper voltage which when applied to input
channel casing or between input channels does not damage them)
None * Input cord optional
*Not compatible with Model 8826
Dimensions and mass:
Approx. 170W × 20H × 148D mm, approx. 310g
8947
CHARGE UNIT 8947
Input
Number of channels: 2
Measurement objects can be selected individually for each channel.
Full isolation between inputs, and between inputs and recorder.
Common GND for voltage input and charge input channels.
Voltage and pre-amplifier internal inputs: BNC terminals
(With voltage input: input resistance, 1MΩ ; input capacitance, less than 200 pF)
Charge input: miniature connector (#10-32 UNF)
Charge input: piezoelectric charge output acceleration
Suitable converters
pickup sensors, Internal pre-amplifier input: acceleration
pickup sensors with built-in pre-amplifier
50m (m/s2)/DIV to 10 k (m/s2)/DIV, 12 ranges×6 types, the
Measurement ranges
measurement resolution is 1/80 to 1/32 of range (changes according
Charge input
to measurement sensitivity) Measurement sensitivity: 0.1 to 10pC
(miniature connector)
/ (m/s2), Pre-amplifier internal input measurement sensitivity:
Pre-amplifier internal
0.1 to 10mV/ (m/s2), Amplitude accuracy: ±2 % f.s., Frequency
input (BNC terminal)
characteristics: 1 to 50 kHz +1/ -3 dB, Low-pass filter: 500 / 5kHz,
Pre-amplifier driving power supply: 2mA ±20%, +15V ±5%,
Highest input charge : ±500pC (high sensitivity side 6 ranges),
±50000 pC (low sensitivity side 6 ranges)
500µV to 2V/DIV, 12 ranges, the measurement resolution is 1/80
Measurement ranges
to 1/32 of range (changes according to measurement sensitivity)
Voltage input
DC amplitude accuracy: ±0.4% f.s., Frequency characteristics:
(BNC terminal)
DC to 400kHz +1/ -3 dB, Low-pass filter: 5 / 500 / 5k/ 100kHz,
Input coupling: DC, AC, GND, Max. allowable input: 30V rms or 60V DC
Maximum sampling rate 1 MS/s (simultaneous sampling of two channels)
Max. grounding voltage 30V rms or 60V DC (upper voltage which when applied to input
channel casing or between input channels does not damage them)
None * Input cord optional
Accessories
MEMORY HiCORDER
Common options for 8800 series
*Designated products are not CE-Mark compliant
Note: Product names appearing herein are trademarks or registered trademarks of the various companies.
Logic Signal Measurement
LOGIC PROBE
9321(9321-01)
Case
LOGIC PROBE
9320(9320-01)
4-channel isolated, on/off
detection of AC/DC voltage
CARRYING CASE 9397-01
(for 8841 and 8855)
4-channels, on/off detection of
voltage/contact signal
PC CARD
PC CARD
PC CARD
PC CARD
128 MB
256 MB
512 MB
1GB
(for 8842 only)
with casters for convenient
transportation.
9726
9727
9728
9729
Instrument
DC Power Supply
DC POWER
ADAPTER 9433
Supplies operating
power in the range 10
to 28 V DC.
(8841 and 8842)
MEMORY BOARD 9608
Expands instrument memory by 4×
Must specify when ordering: not user installable.
(8841, 42 only)
PC Communication
Input Modules
RS-232C CARD 9557
(compliance with the PCMCIA
Standard)
Recorders, Memory Recorders
Storage Media
CARRYING CASE 9349
High-voltage input
GP-IB CARD 9558
(compliance with the PCMCIA
Standard) * With a GP-IB cable,
cord length : 2m (6.6 feet)
POWER CORD 9324
LAN COMMUNICATOR
9333
DIFFERENTIAL
PROBE 9322
software required to use
LAN connection with
Windows 95/ 98/ Me,
WindowsNT 4.0 / XP
for up to 2 kV DC, 1 kV AC
for logic terminal
POWER CORD 9325
for 8940 sensor terminal
*LAN CARD (HIOKI-tested)
(compliance with the PCMCIA Standard)
Manufactured by third parties.
(*Non-CE mark)
Various input modules
Install by inserting into the instrument
Can be replaced by user
ANALOG UNIT
VOLTAGE/TEMPERATURE UNIT
FFT ANALOG UNIT
STRAIN UNIT
F/V UNIT
4ch ANALOG UNIT
CHARGE UNIT
WAVE PROCESSOR 9335
software required to convert the
binary file to CSV text file, to remote
control with Windows 95/ 98/ NT
4.0 /Me/ 2000/ XP
8936
8937
8938
8939
8940
8946
8947
CONNECTION CORD
9197
for high voltage (up to 500V)
CONNECTION CORD
9198
for low voltage (up to 300V)
(9332 only)
Current Measurement, other options
9555
9279
9318
9272
CLAMP ON PROBE 9018-10 CLAMP ON PROBE *9132-10
Input from 10 to 500 A
40 Hz to 3 kHz for 0.2 V AC
output. BNC terminal
Input from 20 to 1000 A
40 Hz to 1 kHz for 0.2 V AC output.
BNC terminal
Banana-to-BNC, use to connect
to BNC terminal on Input
Module
CONNECTION CORD 9217
Insulation BNC-to-insulation
BNC, use to connect to
insulation-BNC terminal on
Input Module
For 100V/15A, convenient for
measuring 100 VAC line current
with clamp-on probe
CONNECTION CORD *9165
Metal BNC-to-metal BNC,
use to connect to metal-BNC
terminal on Input Module
PT *9303
9278
9277
9270
Insulation transformer, 400 V or
200 V AC input, 10 V AC output,
for AC power line measurement.
9271
UNIVERSAL CLAMP ON CT 9277
CLAMP ON SENSOR *9271
UNIVERSAL CLAMP ON CT 9278
Enables observation of distorted AC current
waveforms. Input: up to 200 A, 5 to 50 kHz
for 2 VAC out
CLAMP ON SENSOR *9272
Enables observation of distorted AC current
waveforms. Input selectable 20/200 A, 5 to 10
kHz for 2 VAC out
Note : Can only be used in combination with the
SENSOR UNIT 9555 or F/V UNIT 8940 .
CONVERSION CABLE 9318
Connects 9270 to 9272, 9277 to 9279
clamp-on sensors to F/V UNIT 8940.
220H
PAPER WINDER *220H
CLAMP ON SENSOR *9270
Enables observation of distorted AC current
waveforms. Input: up to 20 A, 5 to 50 kHz for
2 VAC out
CONVERSION ADAPTER 9199 *CT-101A LINE SPLITTER
9555
Observe waveforms from DC to distorted AC.
Input up to 20 A, DC to 100 kHz for 2 VAC
out
Paper width 70 − 220 mm
AC100V
POWER SUPPLY 3269/3272
Observe waveforms from DC to distorted AC.
Input up to 200 A, DC to 100 kHz for 2 VAC
out
CONVERSION CABLE 9319
UNIVERSAL CLAMP ON CT *9279
Observe waveforms from DC to distorted AC.
Input up to 500 A, DC to 20 kHz for 2 VAC
out
Note : Can only be used in combination with the
SENSOR UNIT 9555 or F/V UNIT 8940 .
SENSOR UNIT *9555
Used together with 9270 to 9272, 9277 to
9279 clamp-on sensors. Power supply unit.
3274
3273-50
Connects 3273, 3273-50 to
8940 F/V UNIT.
CLAMP ON PROBE 3273-50/3276
Wide (DC to 50 MHz/100 MHz) range, mA-level to 50 A
peak current. Requires power from 3272 or 3269 or F/V
UNIT 8940.
CLAMP ON PROBE 3274/3275
Wide (DC to 10 MHz) range, mA-level to 500 A rms
current.
Requires power from 3272 or 3269 only and requires
scaling operations
10
MEMORY HiCORDER
8855
8ch high-speed isolated inputs of 20MS/s, Max.
512 M words long storage memory
●Maximum 8 analog channels and 16 logic channels
●20MS/s, 8ch 12-bit high-speed isolated Input (8950/8951/8952)
●1MS/s, 8ch 16-bit HIGH RESOLUTION Input (8953-10)
●Max. 512 M words long storage memory
●Zoom and scroll functions providing enlarged and compressed
displays
●Standard LAN/SCSI interface
SPECIFICATIONS
Measurement ranges
using 8950 ANALOG UNIT /option
Frequency band
Time axis at memory function
Functions
Number of input channels
Memory capacity
Data storage
Interfaces
Display and recording
Other functions
Recorders, Memory Recorders
Power supply
Dimensions, mass
Accessories
5 mV to 20 V/division, 12 ranges (20 division f.s.)
resolution: 1/100 of range
DC to 10 MHz ±3dB Sampling speed max.20MS/s
5µs to 5 minutes/division, 24 ranges (1 division =100 samples)
Memory, Recorder (Included X-Y), Rec & Memory, FFT/function
8 analog channels plus 16 logic channels
(analog inputs are isolated up to 370V)
4M words/channel (Total 32MW)
Max.64M words/channel (Total 512MW)(Option)
FDD×1, Type-II PC card×1; PC CARD 9626-9728
(HDD×1/option)
LAN, SCSI, GP-IB or RS-232C (Option, use PC card)
10.4 inch TFT color LCD
(option; 216mm×30m, roll type thermal paper)
Scaling, Waveform judgment,
Waveform processing calculations,
Waveform parameter calculations,
Memory segmentation,Waveform zoom display,
Clock, Cursor readout, Comment entry, etc.
100 to 240V AC 50/60 Hz Max. 180VA
275W×285H×170D mm, 6.3kg
Power cord(1), PC card protector(1)
Input cord label(1), Wave viewer software(1)
OPTIONS
(The 8855 cannot be used alone. Measurement requires optional input unit or similar
peripheral.)
●Options (Factory fitted)
PRINTER UNIT
8994
MEMORY BOARD (96MW)
9645
MEMORY BOARD (512MW)
9645-01
HD UNIT (20GB)
9663
●Options
ANALOG UNIT
8950
VOLTAGE/CURRENT UNIT
8951
DC/RMS UNIT
8952
HIGH RESOLUTION UNIT
8953-10
VOLTAGE/TEMP UNIT
8954
F/V UNIT
8955
CONNECTION CORD (500V Max.) 9197
CONNECTION CORD (300V Max.) 9198
CONNECTION CORD (BNC-BNC) 9217
RECORDING PAPER (30m, 6 rolls /1set)
9231
DIFFERENTIAL PROBE
9322
POWER CORD (for 8950/8953-9322) 9328
LOGIC PROBE
9327
STANDARD
STANDARD
OPTION
LOGIC PROBE
9321-01
LAN COMMUNICATOR
9333
WAVE PROCESSOR
9335
CARRYING CASE
9397-01
RS-232C CARD
9557
GP-IB CARD
9558
FUNCTION UP DISK
9549
LAN CABLE
9642
PC CARD 128 MB
9726
PC CARD 256 MB
9727
PC CARD 512 MB
9728
PC CARD 1 GB
9729
CLAMP ON SENSORs (refer to p.34-36)
Other common options (refer to p.10)
OPTION
Input modules
Install or replace simply by inserting
the module into the base unit
Note: Input cords are not provided.
Please purchase the appropriate
input cord for the probe type and
application separately.
ANALOG UNIT
8950
VOLTAGE/CURRENT UNIT 8951
DC/RMS UNIT
8952
HIGH RESOLUTION UNIT 8953-10
VOLTAGE/TEMP UNIT
8954
F/V UNIT
8955
Logic input
LOGIC PROBE 9327
4 channels, ON/OFF detection of
voltage/contact signals (high-speed type
for use with the 8855)
FUNCTION UP DISK 9549
Voltage, current, and power
waveforms on the secondary side
of an inverter
MEMORY BOARD 9645
(total 128 megawords)
Expands instrument memory by 4
times its original size. Specify upon
order; factory installation only.
MEMORY BOARD 9645-01
(total 512 megawords)
Expands instrument memory by 16
times its original size. Specify upon
order; factory installation only.
11
HD UNIT 9663
Specify upon order; factory
installation only. (20 GB)
By installing the power monitor
function in the MEMORY
HICORDER 8855, you can monitor
power transient waveforms and
view power trend graphs. Use of
this function requires the optional
FUNCTION UP DISK 9549,which is
sold separately
LOGIC PROBE 9321-01
4 isolated channels, ON/OFF detection
of AC/DC voltage (small terminal-type
for use with the 8855, 8807-01, and
8808-01)
ADAPTER CABLE 9323
(Terminal conversion cable for
connecting the all-purpose LOGIC
PROBE 9321 and the 8855 when
terminals do not match.)
MEMORY HiCORDER
8807-01 8808-01
New concept incorporating detachable printer,
B5-sized handy recorder
●B5 book-sized, compact, and handy high-speed recorders
●2 analog channels (8807-01) 4 analog channels (8808-01) isolated
inputs (with 8 logic)
●PC card slot, 4-way power supply, and powerful trigger functions
●Fax/modem communication function (9332)
SPECIFICATIONS
Measurement ranges
OPTIONS
(The 8807-01 & 8808-01 cannot be used alone. Measurement requires optional INPUT
CORD or similar peripheral.)
8992
PRINTER UNIT (print size 100 mm width)
RECORDING PAPER (18m, 10 rolls /1 set)
LOGIC PROBE (refer to p.10)
LOGIC PROBE (refer to p.10)
CONVERSION CABLE
CARRYING CASE (soft)
CARRYING CASE (hard)
AC ADAPTER (universal 100 to 240VAC, 12VDC/2.5A output)
BATTERY PACK (7.2V, 2400 mAh, recharging with the 9418-15)
RS-232C CABLE (mini DIN 9-pin to Dsub 9-pin, 1.5 m)
CLAMP ON SENSORs (refer to p.34~36)
WAVE PROCESSOR
CHARGE STAND
Other common options (refer to p.10)
8808-01
Recorders, Memory Recorders
10 mV to 100 V*1/division, 13 ranges (10 division f.s.), resolution:
1/160 of range, *1 100 V/division excludes the RMS & memory
recorder functions
Frequency band
DC to 50 kHz, ±3 dB
Time axis at memory function 200µs to 5 minutes/division, 19 ranges (1 division =80 samples)
Functions
Memory recorder, Recorder, RMS & memory
recorder (50/60 Hz or DC only)
Number of input channels 8807-01: fixed input section, 2 analog*2 +8 logic
8808-01: fixed input section, 4 analog*2 +8 logic
*2 analog inputs are isolated up to 450V
Memory capacity
(analog 12 bits+ logic 4 bits)×256 k words*/channel * using CH1
Data storage
PCMCIA Type-II PC card ×1
PC CARD 9726-9729
Interfaces
RS-232C, Printer (PRINTER UNIT 8992 can be connected)
Recording and display 112 mm×18 m, roll type thermal paper, Recording speed: 10 mm/s
(using AC adapter), 5 mm/s (using batteries), 5.7-inch STN color LCD
Power supply
AC ADAPTER 9418-15, LR6 (AA)×6 (Continuous use 1 hour,
LR6 batteries cannot be used with PRINTER UNIT 8992),
BATTERY PACK (Continuous use 3 hours) 9447,
12V DC Car battery
Dimensions, mass
203W×170H×52D mm (printer detached)
280W×170H×52D mm (printer attached)
8807-01: 1.1 kg (printer detached), 1.5 kg (printer attached)
8808-01: 1.2 kg (printer detached), 1.6 kg (printer attached)
Accessories
LR6 (AA) Alkaline batteries(6), Alkaline battery
box(1), Shoulder belt(1), Wave viewer software(1)
8992
9234
9320-01
9321-01
9323
9391
9648
9418-15
9447
9612
9335
9643
*Note: An input cord is not supplied with the 8807-01 & 8808-01.
Requires the 9197 or 9198
8992+8807-01
STANDARD
OPTION
MEMORY HiCORDER
8807-51 8808-51
Instantaneous Analysis and Long-term Recording of Harmonic
Waves for Maintenance of Commercial Power Systems
Instantaneous harmonic analysis
●Measure harmonics up to 40 orders from the fundamental wave
●Analysis display includes RMS value, content factor, phase angle,
active power, and power phase angle for each order of harmonics
(numeric and graphic display)
●Analysis display of total RMS value, total distortion, active/
reactive/apparent power, and power factor (numeric display)
●Bar graph and numeric data display
●Power phase angle can be displayed as a vector
Waveform
Bar graph
Numeric data
Power vector
12
WAVE COMPARATOR
8730-10 8731-10
A MEMORY HiCORDER geared for the
production line
●Easy installation into production lines for high speed measurement
and assessment
●Compare the signals of manufactured components and devices with
a memorized reference signal to conduct PASS/FAIL evaluations on a
waveform level
●8730-10: 1ch input/comparison 8731-10: 2ch input/2ch
simultaneous comparison
●Connect to a PC via LAN for networking capabilities
Recorders, Memory Recorders
OPTIONS
STANDARD
STANDARD
LOGGER COMMUNICATOR
Program that enables data collection using
Ethernet and data analysis in Windows
13
SPECIFICATIONS
Measurement ranges 100 mV to 5 V/division, 6 ranges (10 division f.s.)
resolution: 1/160 of range
Frequency characteristic DC to 400 kHz ±3 dB
8730-10: Analog 1 channel 8731-10: Analog 2 channels
Number of input
channels
12bits×50 k words/ch
Memory capacity
100µs to 5 minutes/division, 20 settings (1 division =100 samples)
Time axis
external sampling (up to 1 kHz, minimum sampling period 1 ms)
Measurement functions Memory recorder with waveform evaluation function.
Reference area waveform evaluation
X-Y Measurement function
Waveform parameter calculation
Waveform processing calculation
PC card Type II slot
Data storage
RS-232C LAN (10BASE-T) External I/O
Interfaces
7.2-inch STN color LCD
Display
100 to 240 V AC (50/60 Hz)
Power supply
8730-10:288W×144H×190D mm, 3.6kg
Dimensions, mass
8731-10:288W×144H×190D mm, 3.7kg
Power cord(1), Wave viewer software(1)
Accessories
LAN COMMUNICATOR
WAVE PROCESSOR
PC CARD 128M
PC CARD 256M
PC CARD 512M
PC CARD 1GB
LAN CABLE
9333
9335
9726
9727
9728
9729
9642
(for 8420-51, 8421-51 and 8422-51)
9334
SPECIFICATIONS
Compatible devices MEMORY HiLOGGERs 8420-51, 8421-51 and 8422-51
One CD-R
Supplied Media
Computers running under Windows 95/98/Me or WindowsNT/2000/XP.
Operating
CPU: Pentium (133 MHz) or later, 32-MB memory or more
environment
OS: Windows 95/98/Me or Windows NT 4.0 SP3 or later / 2000/XP.
� Interface: Ethernet � Number of units supported: 16 � Location of
Data transfer
memory data: data can be loaded into the unit's internal memory
functions
� Real-time transfer: data can be loaded in real time (maximum file size:
up to 200 MB), real-time load settings can be made using the remote control
� Waveform Display: displays acquired waveform data as images
Display functions
� Real-time Display: displays real-time transfers as images and allows
the time axis to be split � Digital Value Display: displays waveform data
as digital values, and allows images and digital values to be displayed
simultaneously � Cursor function: allows you to display the time and
potential differences between cursors A and B, the time and electrical
potential between each cursor, and the absolute and relative times
� Scroll function � Maximum number of channels: 512 analog
channels, 256 logic channels, and 64 pulse channels � Data load
format: real-time and memory � Alarm Output Display
� Memory content: criteria settings and measurement data
Storage function
(binary and text formats)
� Target data: all data or data between cursors A and B
Data conversion
� Data interval: simple interval, average value, absolute and
functions
maximum values, maximum and minimum values (can be selected
when saving) � Data conversion: can convert analog and pulse waveform
data into numerical values and logic data into binary � Data conversion
format: CSV � Conversion channel: can be selected when saving
� Target data: all data or data between cursors A and B
Print functions
� Print format: waveforms and numerical values
Parameter calculation � Target data: all data or data between cursors A and B � Target data:
all data or data between cursors A and B � Calculation items: average
functions
value, peak value, maximum value, maximum value time, minimum
value, minimum value time, ON time, OFF time, number of times ON,
number of times OFF, standard deviation, area
� Marking function: inserts an event marker at the start of
Other
measurement � Search functions: Select from event marker, date
(absolute and relative time), trigger, maximum, minimum, peak,
valley, alarm, level, window, or volume of change
MEMORY HiLOGGER
8420-51 21-51 22-51
All analog inputs fully isolated!
Voltage/temperature loggers with PC networking support
●8420-51(8ch), 8421-51(16ch), 8422-51(32ch) All analog channels isolated.
●Temperature, voltage, humidity, cumulative pulses, rotations
●Max. 32-channel, 100ms high-speed multi-channel data collection
●Simultaneous numerical and graphical display
●Attachable Printer and I/O Module
●Up to 16 HiLOGGERs can be connected
and controlled via LAN.
Recorders, Memory Recorders
8421-51
8420-51/8421-51 SPECIFICATIONS
8420-51:Analog 8 channels isolated by Photo-MOS relays
Input Channels
8421-51:Analog 16 channels isolated by Photo-MOS relays
Pulse Inputs 4ch, Logic Inputs 16ch (using the 8993)
Measurement objects
Thermocouple : K,E,J,T,N,W(WRe5-26),R,S,and B
Platinum measurement resistance type : Pt-100 JPt-100
Analog voltage input : 100mV,1V,10V,100V and 1-5V f.s.
Recording interval
100ms to 1hour (5 sec. to 1 hour for humidity measurement)
A/D resolution
16 bits
Memory capacity
Internal : 16MW DRAM (32MB)
External : 9726-9729 PC CARD
Interfaces
RS-232C, LAN (10Base-T Ethernet connectors)
Printer (8992), DIGITAL I/O UNIT (8993)
Display and Recording 5.7-inch STN color LCD, Printer 8992 (Option)
112 mm×18 m, roll type thermal paper,
Recording speed: 2 mm/s
Function
Waveform compression and magnification, Event search,
Waveform scroll, cursor measurement, scaling,
automatic save, start condition retention, setting save,
comment entry, automatic set up, numerical calculation
Power supply
AC ADAPTER 9418-15, BATTERY PACK 9447, 12V DC Car battery
Dimensions, mass
234W×170H×52D mm 1.4kg (instrument only)
310W×170H×52D mm 1.7kg (with printer )
302W×170H×52D mm 1.7kg (with Digital I/O Unit )
Accessories
AC ADAPTER 9418-15(1),
Terminal Cover(1), Screwdriver(1), Wave viewer software(1)
STANDARD
STANDARD
8422-51 SPECIFICATIONS
Input Channels
8422-51:Analog 32 channels isolated by Photo-MOS relays
Pulse Inputs 4ch, Logic Inputs 16ch (using the 8993)
Measurement objects
Thermocouple : K,E,J,T,N,W(WRe5-26),R,S,and B
Analog voltage input : 100mV,1V,10V,100V and 1-5V f.s.
Recording interval
A/D resolution
Memory capacity
100ms to 1hour (16ch) (200 ms to 1 hour)
16 bits
Internal : 16MW DRAM (32MB)
External : 9726-9729 PC CARD
Interfaces
RS-232C, LAN (10Base-T Ethernet connectors)
Printer (8992), DIGITAL I/O UNIT (8993)
Display and Recording 5.7-inch STN color LCD, Printer 8992 (Option)
112 mm×18 m, roll type thermal paper,
Recording speed: 2 mm/s
Function
Waveform compression and magnification, Event search,
Waveform scroll, cursor measurement, scaling,
automatic save, start condition retention, setting save,
comment entry, automatic set up, numerical calculation
Power supply
AC ADAPTER 9418-15, BATTERY PACK 9447, 12V DC Car battery
Dimensions, mass
234W×170H×52D mm 1.4kg (instrument only)
310W×170H×52D mm 1.7kg (with printer )
302W×170H×52D mm 1.7kg (with Digital I/O Unit )
Accessories
AC ADAPTER 9418-15(1),
Terminal Cover(1), Screwdriver(1), Wave viewer software(1)
OPTIONS
PRINTER UNIT (print size 100 mm width)
8992
DIGITAL I/O UNIT
8993
RECORDING PAPER (18m, 10 rolls /1 set)
9234
LOGGER COMMUNICATOR
9334
AC ADAPTER(100 to 240 V AC, 12 V DC/2.5 A output)
9418-15
BATTERY PACK(7.2 V, 2400 mAh, recharging with the 9418-15) 9447
RS-232C CABLE(mini DIN 9-pin to Dsub 9-pin, 1.5 m cross)
9612
RS-232C CABLE(mini DIN 9-pin to Dsub 9-pin, 1.5 m straight)
9721
CONNECTION CORD (for pulse Input)
9641
LAN CABLE
9642
CHARGE STAND
9643
CARRYING CASE
9648
PROTECTIVE CASE (Basic water-resistance) 9649
FIXED STAND
9652-01
HUMIDITY SENSOR
9701
TERMINAL UNIT
9329
PC CARD
128M
9726
PC CARD
256M
9727
PC CARD
512M
9728
PC CARD
1GB
9729
*Note: An input cord is not supplied with the 8420-51, 8421-51 & 8422-51
14
MICRO HiCORDER
8205-10 8206-10
Easy data recording as convenient as a simple
tester, yet with broad functionality
●Record voltage and current variations simply with full line-up of
optional clamp on sensors of up to 1000A
●Input levels can be monitored on the LCD like an analog display
●Built-in thermal printer for printing data such as time and amplitude axis
Recorders, Memory Recorders
8205-10
8205-10: SPECIFICATIONS
DC /AC Voltage: 0.1V to 500V f.s. 12 ranges
Measurement ranges
AC Current: 10A to 1000A f.s. 7 ranges (using CLAMP ON SENSOR / option)
10ms
Sampling period
20Hz to 30kHz, ±3 dB
Frequency band
20cm/minute to 2cm/hour, 5 ranges
Paper feed speed
Number of input channels Voltage or Current, 1 channel
Voltage: ±2% f.s. Current: ±4% f.s.
Accuracy
(using 9651 CLAMP ON SENSOR / option)
100 to 240V AC (50/60 Hz) or 9.5 to 14V DC, 2 way
Power supply
250W×122H×93.5D mm, 1.2 kg
Dimensions, mass
Power cord(1), Recording paper(1 roll), CONNECTION
Accessories
CORD 9257 (1), CARRYING CASE 9344(1)
8206-10: SPECIFICATIONS
AC Voltage: 100/ 200/ 500 V extended scale, 3 ranges
Measurement ranges
AC Current: 10A to 1000A f.s. 7 ranges (using CLAMP ON SENSOR / option)
10 ms
Sampling period
30Hz to 30kHz, ±3dB
Frequency band
60 cm/hour to 2 cm/hour, 5 ranges
Paper feed speed
Number of input channels Voltage and Current, 2 channels alternate recording
Voltage: ±2% f.s. Current: ±4 % f.s.
Accuracy
(using 9651 CLAMP ON SENSOR / option)
100 to 240 V AC (50/60 Hz) or 9.5 to 14 V DC, 2 way
Power supply
250W×122H×93.5D mm, 1.2kg
Dimensions, mass
Power cord(1), Recording paper(1 roll), CONNECTION
Accessories
CORD 9257(1), CARRYING CASE 9344 (1)
8206-10
OPTIONS
9650
9651
CLAMP ON SENSOR 9650
(for 8205-10, 8206-10, 100A f.s.,40Hz~1kHz, 3m length)
CLAMP ON SENSOR 9651
(for 8205-10, 8206-10, 500A f.s.,40Hz~1kHz, 3m length)
CLAMP ON SENSOR 9668
(for 8205-10, 8206-10, 1000A f.s.,40Hz~1kHz, 3m length)
RECORDING PAPER (15m, 10rolls /1 set) 9235
RECORDING PAPER (Climate-resistant, 15m, 10rolls/1set) 9236-01
CONNECTION CORD (for 8205-10 only) 9326
220H PAPER WINDER (refer to p.10)
9668
INTELLIGENT RECODER JULIUS
INR-9000 Series (1 pen to 12 pens)
High speed pen recording and logging
Wide assortment of input units
●INR-9011 (1pen) INR-9021 (2pen) INR-9031 (3pen)
INR-9041 (4pen) INR-9061 (6pen) INR-9081 (8pen)
INR-9101 (10pen) INR-9121 (12pen)
●“INFOMEDIA” New concept
●Fusion of data logging system and multi-recording/indicating media
●Max.12 pen recording & 24ch. data logging
SPECIFICATIONS
Operating method
Input
Recording method
Effective recording width
Pen interval
Max. Pen Speed
Chart speed range
Chart feed
Chart paper
Off-scale protection
Display
Channel expantion
Ambient condition
Power source
DC power source (op.)
Power Consumption
External dimensions
Weight
Accessories
Automatic seif-balancing (digital servo type)
8205: SPECIFICATIONS
Plug-in unit method
DC /AC
Measurement ranges
Disposable feit-tip pen
AC Curre
250mm
SENSOR
3.2mm±0.5mm
Sampling period
10 ms
Max. 1,600mm/s±10%(at AC operation)
Frequency band
20 Hz to
10, 20, 30, 60, 120, 180,300, 600, 1,200mm/h&min
Paper feed speed
20 cm/
(Settable in 1mm step within above ranges)
Number of input channels Voltag
Approx 300mm/min.
Voltag
Accuracy
Z fold type SF-10CXN-35 35mm long (DIN)
Roll type SF-10CX 20mm long (DIN)
(using
Electronic limiter
Power supply
100 to 2
LCD (320×240 dot) with back light & auto off function
Dimensions, mass
250W×
Recording pen can be freely linked with any unit insertion channel
Power co
Accessories
1pen (max.2ch), 2pen (max. 4ch), 3pen (max. 6ch), 4pen
or more (max. 24ch)
CORD(
Main body: 0 to 40°C, 40 to 80%RH
FDD: 10 to 40°C, 40 to 80%RH Printing head: 5 to 40°C, 40 to 80%RH
AC85~132VAC or 170~250VAC (Please specify when ordering)
8207: SPECIFICATIONS
12VDC (11~15VDC), 24VDC (applicable to 1 to 4 pen)
Measurement ranges
Approx. 45VA (1pen), 48VA (2pen), 51VA (3pen), 54VA(4pen),
60VA (6pen), 70VA (8pen), 80VA (10pen), 90VA (12pen)
Approx. 438 (W) × 230 (h) × 334 (d) mm
Approx. 10.2kg (1pen), 10.5kg (2pen), 11.0kg (3pen),Sampling
11.4kg (4pen) , period
12.2kg(6pen), 13.0kg (8pen), 13.7kg (10pen), 14.5kg Frequency
(12pen)
band
· Disposable felt pen (1)/pen
Paper feed speed
· Chart paper SF-10CXZ-35 (1) 35m long Z-fold
Number of input channels
· Ribbon cassette P-1101 (1)
· Power cord (1)
Accuracy
· Instruction manual (1)
OPTIONS
STANDARD UNIT
0.5mV THERMOCOUPLE UNIT
TRANSIENT UNIT
RTD TEMP. UNIT
pH/ORP UNIT
CONDUCTIVITY UNIT
AC VOLTAGE UNIT
AC VOLTAGE LOG UNIT
15
FU-911A
FU-913A
FU-961A
FU-917A
FU-921A
FU-922A
FU-941A
FU-972A
Power supply
Dimensions, mass
Accessories
Electronic Measuring Instruments
Electronic Measuring Instruments Index
For low resistance measurement Batter y Testers
3540, -01, -02, -03
3541
Testing source DC
100 ms response
16 times/sec. sampling
Comparator (buzzer only)
Wide measurement range
0.1µΩ (20m Ω range) to
110MΩ High speed and
High precision
. . . . . . . . . . . . . . . p.17
. . . . . . . . . . . . . . . p.17
3560
Testing source AC 1kHz
50/60 times/sec. sampling
Comparator output, full remote
control, RS-232C included
GP-IB or Printer interface option
. . . . . . . . . . . . . . . p.18
3561
The perfect battery tester
for the production line
Testing source AC 1kHz
EXT I/O, RS-232C, GP-IB
. . . . . . . . . . . . . . . p.18
3554
For medium to highcapacity lead-acid storage
battery: UPS and similar
applications
Check battery deterioration
. . . . . . . . . . . . . . . p.54
3555
For compact storage
batteries: portable
telephones and similar
applications
Check battery deterioration
. . . . . . . . . . . . . . . p.54
3511-50
7 measurement items
Testing source frequency
120Hz, 1kHz
Comparator output, RS-232C
included, GP-IB option
. . . . . . . . . . . . . . . p.19
3522-50
14 measurement items
Testing source frequency
DC, 1mHz to 100kHz
Comparator output,
GP-IB or RS-232C option
. . . . . . . . . . . . . . . p.20
3532-50
14 measurement items
Testing source frequency
42Hz to 5MHz
Comparator output,
GP-IB or RS-232C option
. . . . . . . . . . . . . . . p.20
3535
14 measurement items
Testing source frequency
100kHz to 120MHz
Comparator output
GP-IB and RS-232C
. . . . . . . . . . . . . . . p.19
Signal Sources, Waveform Generators DMMs
7011
DC signal source
Voltage, Current,
Thermoelectric power
Measurement function
. . . . . . . . . . . . . . . p.26
7075 (4ch)
DC signal source Voltage,
7075-01 (2ch)
Current, Measurement function Arbitrary waveform genarator
Function generator, Sweep
sequence function
. . . . . . . . . . . . . . . p.26 . . . . . . . . . . . . . . . p.26
7016
3504/3504-10
3505/3506
C, D Testing
Testing source frequency
120Hz, 1kHz, 100kHz,1MHz
Comparator output, RS-232C
included, GP-IB (3504)
Leakage current of Protective ground
Medical Equipment Test Equipment
3154
3156
Testing voltage 25 /50
/100 /250 /500 /1000 V
Comparator output
Timer function
. . . . . . . . . . . . . . . p.24
Leakage current for use
in testing electric and
medical appliances
RS-232C
. . . . . . . . . . . . . . . p.25
3157-01
Testing source AC
Protective ground
tester indispensable for
standard certification
. . . . . . . . . . . . . . . p.25
C Testing
Testing source signal
4V DC/ one time
Indicator type
. . . . . . . . . . . . . . . p.19
Digital ultraSuper
insulation / micro megohm meter
ammeter
3237/3238/3239 DSM-8104 (1ch) SM-8213/8215
High speed DMM
DSM-8542 (4ch) /8216/8220
199999 count display
. . . . . . . . . . . . . . . p.21
PSU-8541(power source unit)
Measurement voltage :
DC 0.1 - 1,000 V
Measurement range :
1 × 107 - 3 × 1016 Ω
. . . . . . . . . . . . . p.22
Safety Standards Measuring Instruments
Insulation Test
Equipment
3501
Electronic Measuring Instruments
Inductance, Capacitance, or Impedance Meters
Portable Withstanding Insulation/
Voltage HiTESTER
Withstanding Test
Equipment
3173
Basic AC withstand
voltage tester
3kV/30VA
Economical and easy to operate
. . . . . . . . . . . . . . . p.24
3159/3158
2000MΩ/5kV
Insulation and
withstanding voltage tester
3158 : Withstanding voltage
Test only
. . . . . . . . . . . . p.23,24
Measurement voltage :
5 - 1,000 V DC
Meas. range :0.05 - 2 ×
1016MΩ (SM-8220)
. . . . . . . . . . . . . p.22
Automatic Insulation/
Withstanding
Test Equipment
3153
9999MΩ/5 kV AC/DC
Automatic insulation
and withstanding voltage
tester
. . . . . . . . . . . . . . . p.23
16
RESISTANCE HiTESTER
Measure from very low (µΩ) to very high (MΩ)
resistances with a single instrument
●Wide Measurement Range
●0.1µΩ (20 mΩ range) to 110.000 MΩ
●High Speed & High Precision Measurements
●As fast as 0.6 ms with 70 ppm precision (in the 2 kΩ to 110 kΩ
range)
●Two Types of Temperature Correction
●Correction by Pt sensor or Infrared Thermometer
●Equipped with EXT I/O, GP-IB and RS-232C interfaces
●Easily integrates into automated production lines
3541
SPECIFICATIONS
Measurement
Accuracy
Functions
Interface
Power supply
Dimensions
Mass
Accessories
Four-terminal resistance measurement
0.1µΩ (20 mΩ range) to 110.000 MΩ
Low power four-terminal resistance measurement
10µΩ (2Ω range) to 2.00000 kΩ
Temperature measurement (Pt) -10.0 to 99.9°C
Temperature measurement (analog input) 0 to 2V
70ppm of rdg+15ppm of f.s. (2kΩ.20kΩ range slowΩ)
Temperature correction, temperature conversion, self
calibration, measurement fault detection, overflow detection,
offset voltage compensation, average, statistical calculation,
key lock, save/load, comparator, BIN measurement
GP-IB, RS-232C, EXT-I/O
100 to 240 VAC 50/60 Hz
Approx. 215W×80H×295D mm (excluding projections)
Approx. 2.6 kg
CLIP TYPE LEAD 9287-10, TEMPERATURE PROBE 9451,
Power Cord, EXT I/O Male Connector
OPTIONS
Electronic Measuring Instruments
CLIP TYPE LEAD
9452
FOUR TERMINAL LEAD
9453
ZERO ADJUSTMENT BOARD
9454
PIN TYPE LEAD (for ultra precision)
9455
PIN TYPE LEAD
9461
CLIP TYPE LEAD
PIN TYPE LEAD
9465
PIN TYPE LEAD
9770
PIN TYPE LEAD
9771
LARGE CLIP TYPE LEAD
9467
CONNECTION CABLE (for multipolar connectors) 9300
RS-232C CABLE (9pin-9pin/cross/1.8m)
9637
9287-10
RS-232C CABLE (9pin-25pin/cross/1.8m)
9638
GP-IB CONNECTOR CABLE (2m)
9151-02
GP-IB CONNECTOR CABLE (4m)
9151-04
PRINTER
9670
AC ADAPTER (for 9670)
9671
BATTERY PACK (for 9670)
9672
BATTERY CHARGER (for 9672)
9673
RECORDING PAPER (80mm × 25m, 4 rolls)
9237
STANDARD
mΩ HiTESTER
STANDARD
3540 3540-01 3540-02 3540-03
Offers selectable manual measurement or system
application
●4-terminal method milli-ohmmeter (Fast 100-ms Response)
●Comparator function memorizes up to seven tables
●Temperature compensation function measures temperature and
calculates value relative to copper at 20°C
SPECIFICATIONS
Measurement ranges
and Accuracy
Measurement current
Max. applied
measurement voltage
Sampling speed
Response time
Display
Measurement method
Open-circuit terminal voltage
Digital input/output
(-01, -02 and -03 Ver. only)
Comparator functions
Interface
Power supply
Dimensions, mass
Accessories
30 mΩ to 30 kΩ, 7 ranges, 3500 full digits
±0.1 % rdg. ±6 dgt. (30 mΩ, 3Ω range)
±0.1 % rdg. ±4 dgt. (300 mΩ, 30Ω to 30 kΩ range)
100 mA (30 mΩ, 300 mΩ range) to 10µA (3 kΩ, 30kΩ range)
3.5 mV DC (30 mΩ range) to 350 mV DC (30 kΩ range)
16 times /second (fast mode), 4 times /second (slow mode)
100 ms (fast mode), 300 ms (slow mode)
3500 full digits, Liquid Crystal Display
Four-terminal measurement
4.0 V Max. (30 mΩ to 30 kΩ all ranges)
TTL output BCD, or other inputs /outputs for external control
Setting: Upper and lower limit, or reference value and % for
resistance, Up to 7 tables Output: 3 levels (Hi, In, Lo),
Open-collector, LED display, beep sound
External printer (-02 only), RS-232C (-03 only)
LR6 (AA) or R6P (AA)×6, or 9445-02, -03 AC ADAPTER (9V, 1A)
215W×61H×213D mm, 900 g, 1 kg (-01,-02,-03)
CLIP-TYPE LEAD 9287-10(1), TEMPERATURE PROBE 9451(1),
Fuse(1), Ferrite Clamp(2), External Connector Socket (-01 only)
OPTIONS
Model 3540-03
The 3540 is the low-price version without external control interfaces, for
manual measurement. The 3540-01 adds BCD output and external control,
the 3540-02 includes a printer interface and the 3540-03 includes an RS-232C
interface.
17
DIGITAL PRINTER
RECORDING PAPER (10 m, 10 rolls /1set)
CONNECTION CORD (for 9203-3540-02, 2m)
AC ADAPTER (100 to 240 VAC, 9 V/1A output, for USA)
AC ADAPTER (100 to 240 VAC, 9 V/1A output, for EU)
CLIP TYPE LEAD
FOUR-TERMINAL LEAD
PIN TYPE LEAD
PIN TYPE LEAD
PIN TYPE LEAD
PIN TYPE LEAD
CLIP TYPE LEAD WITH TEMPERATURE SENSOR
LARGE CLIP-TYPE LEAD
RS-232C CABLE (9pin-9pin)
RS-232C CABLE (9pin-25pin)
9203
9233
9425
9445-02
9445-03
9452
9453
*9455
9461
9770
9771
9460
9467
9637
9638
*Note: The 9455 probe is a precision instrument. Exercise appropriate care when
handling it.
3560
AC mΩ HiTESTER
For measurement requirements from contact
resistance to internal resistance and voltage of
batteries
SPECIFICATIONS
Measurement ranges
Accuracy
Measurement current
Max. applied
measurement voltage
Sampling speed
●Fast response time approximately 84 ms (60 Hz)
●Low-power resistance measurement
●Battery measurement
●High-resolution (1µΩ in the 30mΩ. range)
30 mΩ to 3 kΩ, 6 ranges, ±0.5 % rdg. ±8 dgt. (all ranges)
In case of MEDIUM: Add 3 dgt. to the above dgt. error.
FAST: ±0.5 % rdg. ±8 dgt. (30 mΩ), ±0.5 % rdg. ±6 dgt.
(other ranges), However, in case of FAST, the display counter
decreases 4 digits in all ranges.
7.4 mA (30 mΩ range) to 1.5µA (3 kΩ range)
60 V DC (AC input is not possible)
50 times /s (FAST) to 1.56 times /s (SLOW) :at 50 Hz mode
60 times /s (FAST) to 1.88 times /s (SLOW) :at 60 Hz mode
Display
31000 full digits (resistance), 50000 full digits (voltage),
Fluorescent tube.
Measurement method 1 kHz AC four-terminal measurement
Open-circuit terminal voltage 20mV peak max. (30 mΩ to 3 kΩ all ranges)
Comparator functions Setting: Upper and lower limit, Up to 30 tables
Output: 3 levels (Hi, In, Lo) or (Pass, Fail), Open-collector,
Display, Beep sound
Interface
RS-232C (standard), GP-IB or External printer (option)
Power supply
100 to 240 V AC, 50/60 Hz
Dimensions, mass
215W×80H×320D mm, 2.1 kg
Accessories
CLIP-TYPE LEAD 9287-10 (1), Power cord(1)
OPTIONS
OPTION
STANDARD
BATTERY HiTESTER
9203
9233
9425
9452
9453
9454
*1 9455
9461
9465
9770
9771
9466
9467
*2 9588
9589
9151-02/04
Electronic Measuring Instruments
DIGITAL PRINTER
RECORDING PAPER (10 m, 10 rolls /1set)
CONNECTION CORD (for 9203-3560, 2m)
CLIP TYPE LEAD
FOUR-TERMINAL LEAD
ZERO ADJUSTMENT BOARD (when 9461 or 9465 is used)
PIN TYPE LEAD
PIN TYPE LEAD
PIN TYPE LEAD
PIN TYPE LEAD
PIN TYPE LEAD
REMOTE CONTROL SWITCH
LARGE CLIP-TYPE LEAD
GP-IB INTERFACE
PRINTER INTERFACE
GP-IB CONNECTION CABLE (2 m /4 m)
*1Note: The 9455 probe is a precision instrument. Exercise appropriate care
when handling it.
*2Note: Non-CE mark product
3561 3561-01
Simultaneous high-speed testing of the internal
resistance and voltage of small secondary
batteries
SPECIFICATIONS
Measurement ranges
and Accuracy
Measurement current
Max. applied
measurement voltage
●The perfect battery tester for the production line
●High speed and reliable battery inspection
●High precision accuracy
●Choice of PC interfaces for full remote operation
Sampling speed
Display
Measurement method
Comparator functions
Panel save/load
Other functions
Interface
Power supply
Dimensions, mass
Accessories
300 mΩ to 3Ω, 2 ranges, ±0.5 % rdg. ±5 dgt.
20 V, ±0.01 % rdg. ±3 dgt. (Input impedance 1MΩ)
10 mA (300 mΩ range) to 1 mA (3Ω range)
±22 V DC rated input voltage
±70 V DC maximum rated voltage above ground
Four steps 7 ms(Extra-FAST), 23 ms(FAST),
83/69 ms(Medium), 258/251 ms(Slow)
31000 full digits (resistance), 199999 full digits (voltage),
Fluorescent tube
1kHz AC four-terminal measurement
Setting: Upper and lower limit
Output: 3 levels (Hi, In, Lo) or (Pass, Fail), Open-collector,
Display, Dual audible indicator
Up to 126 configuration settings
Over-range display, measurement error detection
Self-calibration, dual comparators, key-lock
External I/O, RS-232C, Printer (RS-232C), GP-IB(Model 3561-01)
100 to 240 V AC, 50/60 Hz
215W×80H×295D mm, 2.4 kg
Power cord(1)
OPTIONS
OPTION
STANDARD
(Choose Model 3561-01)
CLIP TYPE LEAD
CLIP TYPE LEAD
FOUR TERMINAL LEAD
PIN TYPE LEAD (for ultra precision)
LARGE CLIP TYPE LEAD
PIN TYPE LEAD
PIN TYPE LEAD
RS-232C CABLE (9pin-9pin/cross/1.8m)
RS-232C CABLE (9pin-25pin/cross/1.8m)
GP-IB CONNECTOR CABLE (2m)
GP-IB CONNECTOR CABLE (4m)
PRINTER
AC ADAPTER (for 9670)
BATTERY PACK (for 9670)
BATTERY CHARGER (for 9672)
RECORDING PAPER (80 mm × 25 m, 4 rolls)
9287-10
9452
9453
9455
9467
9770
9771
9637
9638
9151-02
9151-04
9670
9671
9672
9673
9237
18
LCR HiTESTER
3535
High-speed LCR meter with up to 120MHz sampling
●Wide range from 100kHz to 120MHz
●High speed LCR testing (6ms/sample)
●Removable head amplifier
●"Load compensation function" for comparing standard component
and providing compensation
STANDARD
STANDARD
Electronic Measuring Instruments
LCR HiTESTER
3511-50
Compact & powerful dedicated LCR measurement
in 5m second timeframes
●High speed measurement : 5ms (1 kHz) or 13ms (120 Hz)
●High precision accuracy : ±0.08 %
●Built-in comparator
SPECIFICATIONS
Measurement parameters �Z�, �Y�, Q, Rp, Rs(ESR), G, X, B, θ, Ls, Lp, Cs, Cp, D(tanδ)
1kΩ range
10kΩ range
100kΩ range
Z.R
100Ω to 2kΩ
1kΩ to 20kΩ
10kΩ to 300kΩ
Measurement Range:
Reference Value
C
4.4fF to 159pF
0.66pF to 15.9µF 0.066pF to 1.59nF
L
0.133nH to 3.18mH 1.33µH to 31.8mH 13.3µH to 477mH
θ
-180.00° to 180.00°
Range
100kHz to 120MHz
Resolution setting
4digits (when using front panel to make setting)
100.0kHz to 1.000MHz
100Hz steps
1.000MHz to 10.000MHz 1kHz steps
Measurement
Frequency
10.00MHz to 100.0MHz
10kHz steps
100.0MHz to 120.0MHz
100kHz steps
When using GP-IB or RS-232C interfaces, resolution is 1Hz.
Accuray
±0.005% max. against set value
5mV to 1V, max. 20mA (up to 10.000MHz)
Open Terminal Voltage (V)
and Constant Voltage (CV) Modes 5mV to 500mV, max. 10mA (from 10.01MHz)
Resolution
1mV steps
Measurement
Accuracy
±(5%+5mV)×(2+log f) (f in terms of MHz)
Levels
200µA to 20mA, max. 1V (up tp 10.00MHz)
Constant Current (CC)
Mode
200µA to 10mA, max. 0.5V (from 10.01 MHz)
Resolution
10µA steps
Accuracy
±(10%+50µA)×(2+log f) (f in terms of MHz)
Basic accuracy
�Z� : ±0.5% rdg.; θ: ±0.3°
Output impedance
50Ω ±10Ω (at 100kHz)
Power Supply
100V to 240V AC, 50/60Hz Approx.50VA
Dimensions, mass
Approx. 360W×130H×360D mm ; 8.3kg
OPTIONS
(Model 3535 cannot be used alone. Measurement requires optional head amp unit and test fixture or Probe. )
HEAD AMP UNIT
9700-10 GP-IB CONNECTION CABLE (2m/4m)
9151-02/04
SMD TEST FIXTURE *9677
PRINTER
9442
AC ADAPTER (for the 9442, EU), 9443-03 (USA) 9443-02
SMD TEST FIXTURE 9699
CONNECTION CABLE (for the 3535/9442)
9444
CONNECTION CABLE 9678
RECORDING PAPER (25m, 10rolls/1set, for the 9442) 1196
*Note: Non-CE mark product RS-232C CABLE (9pin-9pin/1.8m)
9637
RS-232C CABLE (9pin-25pin/1.8m)
9638
SPECIFICATIONS
Measurement parameters �Z�, θ, C, L, D, Q, R
Measurement method Source : open teminal voltage 50mV, 500mV, 1Vrms (AC)
sense: voltage, AC
Source frequency
120 Hz or 1 kHz
Measurement ranges
�Z�, R : 10 mΩ to 200.00 MΩ (depending on condition)
θ : -90.00 to +90.00°, C : 0.940 pF to 999.99 mF,
L : 1.600 µH to 200.00 kH, D : 0.0001 to 1.9900,
Q : 0.85 to 999.99
Basic accuracy
�Z� : ±0.08% rdg. , θ: ±0.05°
Measurement times
Fast : 5 msec. to Slow : 300 msec. (at 1 kHz)
Fast : 13 msec. to Slow : 400 msec. (at 120 Hz)
Display
99999 full digits, LED
Comparator functions Setting : Upper and lower limit, absolute value,
Output : 3 levels (Hi, In, Lo), Open-collector, Isolated
External printer
9442 (use with the 9443-02 or -03/9444)
Power supply
100 to 240 V AC, 50/60Hz
Dimensions, mass
210W×100H×168D mm, 2.5 kg
Accessories
Power cord(1), Fuse(1)
OPTIONS
OPTION
STANDARD
C HiTESTER
(The 3511-50 cannot be used alone. Measurement requires optional test fixture or probe.)
FOUR-TERMINAL PROBE (DC to 100 kHz)
9140
PINCHER PROBE (DC to 5 MHz)
9143
TEST FIXTURE (cable connection type, DC to 5 MHz)
9261
TEST FIXTURE (direct connection type, DC to 5 MHz)
9262
SMD TEST FIXTURE (direct connection type, DC to 5 MHz) 9263
DC BIAS VOLTAGE UNIT (± 40 V DC max.)
9268
DC BIAS CURRENT UNIT (± 2 A DC max.)
9269
CONNECTION CORD (for 9268/9269; BNC to BNC, 1.5 m) 9165
CONNECTION CORD (for 9268/9269; BNC to clip, 1.5 m) 9166
GP-IB CONNECTION CABLE (2 m /4 m)
9151-02/04
GP-IB INTERFACE
9518-01
PRINTER
9442
AC ADAPTER (for the 9442, EU), 9443-03 (USA)
9443-02
CONNECTION CABLE (for the 3511-50/9442)
9444
RECORDING PAPER (25 m, 10 rolls/1 set, for the 9442)
1196
3504 3504-10 3505 3506
A capacitance measurement instrument for
High-speed MLCC Inspection with Constant Voltage
3504,3505,3506
STANDARD
SPECIFICATIONS (3504,3504-10)
Measurement items
Cs, Cp, D (loss coefficient)
Measurement frequency 120 Hz or 1kHz, Accuracy : ±0.01% or less signal level:1 V or 500 mV
C : 0.940 pF to 20.0000 mF (5-digit display), Accuracy : ± 0.1 %
Measurement range
D : 0.0001 to 1.9900, Accuracy : ± 0.0016
Measurement time Nominal 2 ms (1kHz, FAST) Measurement speed:FAST, NORMAL, SLOW
Comparator, Audible buzzer, Printer (option) Bin (3504 only)
Other function
Phase-synchronous function
RS-232C and EXT I/O (standard) GP-IB (3504 only)
Interface
AC 100 V, 120 V, 220 V, or 240 V ±10% (selectable),50/60 Hz, 100 VA max.
Power supply
Dimensions and mass Approx. 260 H×100 W×220 D mm, 3.8 kg
Supplied accessories Power cord (1), spare fuse (1)
3505.........Measurement frequency 1kHz, 100kHz, 1MHz
3506.........Measurement frequency 1kHz, 1MHz
*3505 and 3506 available in June 2007
19
LCR HiTESTER
3522-50
Better functionality and performance at a low cost
●High speed measurement of 5 ms LCR meter
●Higher frequency range (DC or 1 mHz to 100 kHz)
●Fourteen parameters measured (High resolution and high accuracy)
●DC resistance measurement
SPECIFICATIONS
Measurement parameters �Z�, �Y�, θ, Rp(DCR), Rs(ESR, DCR), G, X, B, Cp, Cs,
Lp, Ls, D(tanδ), and Q
Measurement method Source: constant current 10µ to 100 mA(AC/DC), or
constant voltage 10 mV to 5 V (AC/DC)
open teminal voltage
DC, or 1mHz to 100kHz
Source frequency
�Z�, �R�, X: 10.00 mΩ to 200.00 MΩ (depending on condition)
Measurement ranges
θ: -180.00 to +180.00°, C: 0.3200 pF to 1.0000 F,
L: 16.000 nH to 750.00 kH, D: 0.00001 to 9.99999,
Q: 0.01 to 999.99, �Y�, G, B: 5.0000 nS to 99.999 S
�Z�: ±0.08 % rdg. , θ: ±0.05°
Basic accuracy
Fast: 5 msec. to Slow2: 828 msec.
Measurement times
typical values for displaying Z
99999 full digits, LCD with backlight display
Display
Comparator functions Setting: Upper and lower limit, percentage, or
absolute value, Output: 3 levels (Hi, In, Lo), Open-collector,
Isolated
9442 (use with the 9443-02 or -03/9446/9593-01)
External printer
100 to 240 V AC, 50/60Hz
Power supply
313W×125H×290D mm, 4.5 kg
Dimensions, mass
Power cord(1), Fuse(1)
Accessories
OPTIONS
OPTION
OPTION
LCR HiTESTER
FOUR-TERMINAL PROBE (DC to 100 kHz)
PINCHER PROBE (DC to 5 MHz)
TEST FIXTURE (cable connection type, DC to 5 MHz)
TEST FIXTURE (direct connection type, DC to 5 MHz)
SMD TEST FIXTURE (direct connection type, DC to 5 MHz)
DC BIAS VOLTAGE UNIT (± 40 V DC max.)
DC BIAS VOLTAGE UNIT (±4V DC max. for HDMI )
DC BIAS CURRENT UNIT (± 2 A DC max.)
CONNECTION CORD (for 9268/9269; BNC to BNC, 1.5 m)
CONNECTION CORD (for 9268/9269; BNC to clip, 1.5 m)
GP-IB CONNECTION CABLE (2 m /4 m)
GP-IB INTERFACE
RS-232C INTERFACE
PRINTER
AC ADAPTER (for the 9442, EU), 9443-03 (USA)
CONNECTION CABLE (for the 3522-50 /9442)
RECORDING PAPER (25 m, 10 rolls /1 set, for the 9442)
9140
9143
9261
9262
9263
9268
9268-01
9269
9165
9166
9151-02/04
9518-01
9593-01
9442
9443-02
9446
1196
Electronic Measuring Instruments
(The 3522-50 cannot be used alone. Measurement requires optional test fixture or probe.)
3532-50
Impedance meter with a wide test frequency range
●Higher frequency range (42 Hz to 5 MHz)
●High speed measurement of 5 ms LCR meter
●Interactive touch panel operation
●Wide setting range for measurement voltage and current
SPECIFICATIONS
Measurement parameters �Z�, �Y�, θ, Rp, Rs(ESR), G, X, B, Cp, Cs, Lp, Ls,
D(tanδ), and Q
Measurement method Source: constant current 10µ to 100 mA (42 Hz to 1 MHz),
50µ to 20 mA (1 MHz to 5 MHz), or constant voltage 10 mV
to 5 V (42 Hz to 1 MHz), 50 mV to 1 V (1 MHz to 5 MHz)
open teminal voltage
42 Hz to 5 MHz
Source frequency
Measurement ranges
�Z�, R, X: 10.00 mΩ to 200.00 MΩ(depending on condition)
θ : -180.00 to +180.00°, C: 0.3200 pF to 370.00 mF,
L : 16.000 nH to 750.00 kH, D : 0.00001 to 9.99999,
Q : 0.01 to 999.99, Y,G,B : 5.0000 nS to 99.999 S
Basic accuracy
�Z�: ±0.08% rdg. , θ: ±0.05°
Measurement times
Fast : 5 msec. to Slow2 : 140 msec.
typical values for displaying �Z�
Display
99999 full digits, LCD with backlight display
Comparator functions Setting : Upper and lower limit, percentage, or
absolute value, Output : 3 levels (Hi, In, Lo), Opencollector, Isolated
External printer
9442 (use with the 9443-02 or -03/9446/9593-01)
Power supply
100 to 240 V AC, 50/60Hz
Dimensions, mass
352W×124H×323D mm, 6.5kg
Accessories
Power cord(1), Fuse(1)
OPTIONS
OPTION
OPTION
(The 3532-50 cannot be used alone. Measurement requires optional test fixture or probe.)
FOUR-TERMINAL PROBE (DC to 100 kHz)
9140
PINCHER PROBE (DC to 5 MHz)
9143
TEST FIXTURE (cable connection type, DC to 5 MHz)
9261
TEST FIXTURE (direct connection type, DC to 5 MHz)
9262
Note: Measurement ranges are limited when using the 9140, 9143
SMD TEST FIXTURE (direct connection type, DC to 5 MHz) 9263
DC BIAS VOLTAGE UNIT (± 40 V DC max.)
9268
DC BIAS VOLTAGE UNIT (±4V DC max. for HDMI )
9268-01
DC BIAS CURRENT UNIT (± 2 A DC max.)
9269
CONNECTION CORD (for 9268/9269; BNC to BNC, 1.5 m) 9165
CONNECTION CORD (for 9268/9269; BNC to clip, 1.5 m)
9166
GP-IB CONNECTION CABLE (2 m /4 m)
9151-02/04
GP-IB INTERFACE
9518-01
RS-232C INTERFACE
9593-01
PRINTER
9442
AC ADAPTER (for the 9442, EU), 9443-03 (USA)
9443-02
CONNECTION CABLE (for the 3532-50 /9442)
9446
RECORDING PAPER (25 m, 10 rolls /1 set, for the 9442)
1196
20
DIGITAL HiTESTER
3238 3239
High-accuracy, multi-functional model (3238)
A new DMM with 4-terminal resistance
measurement! (3239)
●Samples at rates of up to 300 samples/sec. (3.3 ms/ sample)
●Comparator function provides high-speed pass/fail evaluation
●Equipped with external input and output for sequence control
●Useful Save/Load function helps work go faster
●Interface supports full remote operation
●AC/DC current and frequency functions
SPECIFICATIONS
DC voltage (DC V)
AC voltage (AC V)
DC current (DC A)
AC current (AC A)
Frequency
Resistance (Ω)
Resistance (LPΩ)
Open terminal voltage
Continuity check
Sampling rate
Display
Ancillary functions
Interface
Power supply
Dimensions and mass
Accessories
200m/2/20/200/1000V(±0.01% rdg. ±2dgt./2V)
2/20/200/750V(±0.1% rdg. ±100dgt./45 to 10kHz) True RMS
200m/2A(±0.1% rdg. ±6dgt./200mA)
200m/2A(±0.3% rdg. ±100dgt./200mA, 45 to 3kHz) True RMS
100/1k/10k/100k/300kHz
(±0.015% rdg. ±2dgt./10 to 300kHz )
200/2k/20k/200k/2000k/20M/100MΩ
(±0.02% rdg. ±2dgt./2k to 200kΩ)
2k/20k/200k/2000kΩ
(±0.02% rdg. ±6dgt./2k to 200kΩ)
6V DC max.(Ω, Diode check)
0.45V DC max.(LPΩ, Continuity check)
A built-in buzzer sounds when the resistance value is
less than 50.00Ω.
FAST approx. 300 samples/s ,
MEDIUM approx.
8 to 9 samples/s , SLOW approx. 1 sample/s
LED max. 199999 (999999 for frequency)
Comparator, Average, Zero Adjust, Trigger
and the Save/Load functions
External input/output,RS-232C, GP-IB(3238-01, 3239-01)
AC 100V/120V/220V/240 V, (50/60Hz)
approx. 215W×80H×265D mm, 2.6 kg
TEST LEAD 9170(1)
Electronic Measuring Instruments
CAT II 300V
CAT I 500V
3238
3238-01
3239-01
STANDARD
3239
DIGITAL HiTESTER
OPTIONS
CLAMP ON PROBE (10/20/50/100/200/500 A AC)
CLAMP ON PROBE (10/20/50/100/200/500 A AC)
CLAMP ON PROBE (20/50/100/200/500/1000 A AC)
RS-232C CABLE (9pin-9pin, Reverse type/1.8m)
RS-232C CABLE (9pin-25pin, Reverse type/1.8m)
GP-IB CONNECTION CABLE (2 m /4 m)
PRINTER
AC ADAPTER (for the 9442, EU), 9443-03 (USA)
CONNECTION CABLE (for 9442 printer)
RECORDING PAPER (25 m, 10 rolls/1 set, for the 9442)
9010
9018
9132
9637
9638
9151-02/04
9442
9443-02
9444
1196
3237
High-speed DMM (3.3ms/sample)
Minimizing tact time with sequence control at a truly affordable price
●Samples at rates of up to 300 samples/sec. (3.3ms/ sample)
●Comparator function provides high-speed pass/fail evaluation
●Equipped with external input and output for sequence control
●Useful Save/Load function helps work go faster
●Interface supports full remote operation
SPECIFICATIONS
DC voltage (DC V)
AC voltage (AC V)
Resistance (Ω)
Resistance (LPΩ)
Open terminal voltage
Continuity check
Sampling rate
Display
Ancillary functions
Interface
Power supply
Dimensions and mass
Accessories
21
200m/2/20/200/1000V(±0.025% rdg. ±2dgt./2V)
2/20/200/750V(±0.2% rdg. ±100dgt./45 to 3kHz) True RMS
200/2k/20k/200k/2000k/20M/100MΩ
(±0.05% rdg. ±2dgt./2k to 2MΩ)
2k/20k/200k/2000kΩ
(±0.05% rdg. ±6dgt./2k to 200kΩ)
6V DC max.(Ω, Diode check)
0.45V DC max.(LPΩ, Continuity check)
A built-in buzzer sounds when the resistance value is
less than 50.00Ω.
FAST approx. 300 samples/s , MEDIUM approx.
8 to 9 samples/s , SLOW approx. 1 sample/s
LED max. 199999
Comparator, Average, Zero Adjust, Trigger
and the Save/Load functions
External input/output,RS-232C, GP-IB(3237-01)
AC 100V/120V/220V/240 V, (50/60Hz)
approx. 215W×80H×265D mm, 2.6 kg
TEST LEAD 9170(1)
3237
OPTIONS
CLAMP ON PROBE (10/20/50/100/200/500 A AC)
CLAMP ON PROBE (10/20/50/100/200/500 A AC)
CLAMP ON PROBE (20/50/100/200/500/1000 A AC)
RS-232C CABLE (9pin-9pin, Reverse type/1.8m)
RS-232C CABLE (9pin-25pin, Reverse type/1.8m)
GP-IB CONNECTION CABLE (2 m /4 m)
PRINTER
AC ADAPTER (for the 9442, EU), 9443-03 (USA)
CONNECTION CABLE (for 9442 printer)
RECORDING PAPER (25 m, 10 rolls/1 set, for the 9442)
CAT II 300V
CAT I 500V
3237-01
STANDARD
9010
9018
9132
9637
9638
9151-02/04
9442
9443-02
9444
1196
Digital ultra-insulation /micro ammeter 1-ch DSM-8104
●Measurement voltage : DC 0.1 to 1,000 V
Measurement range : 1 x 107 to 3 x 1016Ω
●Measures insulation resistance of capacity with high speed &
high accuracy
●High resolution current measurements of 0.1 fA
± (3.0% of rdg+1.2% of range)
± (1.5% of rdg+0.6% of range)
± (0.6% of rdg+0.6% of range)
± (0.4% of rdg+0.5% of range)
± (0.4% of rdg+0.5% of range)
± (0.4% of rdg+0.5% of range)
± (0.4% of rdg+0.5% of range)
± (0.4% of rdg+0.5% of range)
± 4.0% of rdg.
± 4.0% of rdg.
± 2.0% of rdg.
± 0.8% of rdg.
± 0.6% of rdg.
± 0.6% of rdg.
± 0.6% of rdg.
± 0.6% of rdg.
STANDARD
STANDARD
OPTION
Current Limiter
Setting Voltage Range Current Limit Value
5/10/50mA
0.1 to 250.0V
5/10mA
251 to 1,000V
Measurement Check Function
Voltage Monitor, Contact Check Function,
Comparator Measurement, Deviation/Percentage Measurement, Surface/
Measurement Function
Volume Resistivity Measurement
GP-IB, RS-232C, LAN (Option), Handler Interface
Interface, EXT-I/O
100V AC (115V, 220V, 240V factory option), ± 10% at 50/60Hz Approx. 55VA
Power Supply
Approx. 332W × 89H × 450D mm Approx. 6.7kg
Dimension, mass
Power cord (1) (Measurement leads are optional.)
Accessories
OPTIONS
Measurement lead
± (0.1% of setting + 150mV)
± (0.1% of setting + 400mV)
Interlock Connection Cable
Rack Mount Adapter
LAN Interface
Electrodes : refer to P-61
0GE00002 1m, red
0GE00001 1m, black
DSM8104F 1m
DSM8104E
DSM8104D
Digital ultra-insulation /micro ammeter 4-ch DSM-8542
Power source unit PSU-8541
●4-channel, high-speed measurement capability when combined
with PSU-8541 dedicated power source unit sold separately
●System compatibility made easy by connecting charge terminal
handler interface
●Measures insulation resistance of capacity with high speed &
high accuracy
DSM-8542
STANDARD
PSU-8541
STANDARD
Electronic Measuring Instruments
SPECIFICATIONS
Measurement range
DC Measurement Capability
Current Measurement
10pA
100pA
1nA
Measurement Range 10nA
100nA
Name (Accuracy)
1µA
10µA
100µA
Resistance Measurement
1×1014~3×1016 (Open-circuit)
1×1013~1×1014
1×1012~1×1013
Range of
1×1011~1×1012
Measurement
1×1010~1×1011
(Fundamental
1×109~1×1010
Accuracy)
1×108~1×109
1×105~1×107
Measurement Time Setting
0~9,999ms
Delay
2~300ms
Sampling Time
Voltage Generator
Setting Voltage Accuracy and Resolution
Setting Voltage Range 0.1 to 250.0V
251 to 1,000V
Accuracy
SPECIFICATIONS DSM-8542
4-ch same as DSM-8104 Specifications (with PSU-8541
Measurement Specification
dedicated power source unit sold separately)
SPECIFICATIONS PSU-8541
Voltage generator A (HIGH) 1 circuit 250V-150W,
1000V-120W)
Voltage generator B (LO) 1 circuit 10V-6W
Configuration
Current control Circuits (Measurement System) 4 circuits
Current control Circuits (Charge System) 20 circuits
0.1V to 250.0V (±(0.1% of setting +150 mV)) Max.600mA
Voltage Generator (HIGH)
251V to 1,000V (±(0.1% of setting +400 mV)) Max.120mA
0.1V to 10.0V (±(0.1% of setting +150 mV)) Max.600mA
Voltage Generator (LO)
0.1V to 250.0V (5/10/25/50mA) 251V to 1,000V (5mA)
Current limiter
Control by the DSM-8542
Control
100V AC ± 10% at 50/60Hz
Power Supply
Max. Approx. 350VA
Approx. 332W × 178H × 450D mm Approx. 28kg
Dimension, mass
Power cord (1), DSM-8542 Connection Cable (2)
Accessories
OPTIONS
RACK MOUNT ADAPTER LMA-PSU
Electrodes : refer to P-61
OPTION
Super megohm meter SM-8200 Series
SPECIFICATIONS
●Meas. voltages : 5 – 1000V DC
●Digital/analog display on LCD (except SM-8216)
●Equipped with timer, remote starter, comparator & interlock function
●Compatible for measurement of several sample types of electrode
& other devices
STANDARD
5V
10V
15V
Measuring
25V
voltage &
50V
Measuring
100V
range
250V
500V
1,000V
Accuracy of measuring
voltage
Output current
Measuring accuracy
Display
Standard function
Power supply
Dimensions, mass
Accessories
SM-8213
2.5×104 to 1×1011Ω
5×104 to 2×1011Ω
7.5×104 to 3×1011Ω
1.25×105 to 5×1011Ω
2.5×105 to 1×1012Ω
5×105 to 2×1012Ω
SM-8215
SM-8220
SM-8216
5×10 to 2×10 Ω
5×104 to 2×1011Ω
1.25×105 to 5×1014Ω
2.5×105 to 1×1015Ω
5×105 to 2×1015Ω
1.25×106 to 5×1015Ω
2.5×106 to 1×1016Ω
5×106 to 2×1016Ω
1.25×105 to 5×1011Ω
2.5×105 to 1×1012Ω
5×105 to 1×1012Ω
1.25×106 to 5×1012Ω
2.5×106 to 1×1013Ω
5×106 to 1×1013Ω
4
2.5×105 to 1×1012Ω
5×105 to 2×1012Ω
1.25×106 to 5×1012Ω
2.5×106 to 1×1013Ω
5×106 to 2×1013Ω
14
± 3% of setting voltage value
Max. 50mA
Max. 2mA
± 10% (within 10 times range of min. value on each range at 20°C )
LCD (digital & analog display)
timer, comparator (alarm), remote start, HV-EN, RS-232C
100V, 120V, 220V, 240VAC ±10%, but max. 250VAC, 50/60Hz (approx.25VA)
approx.284W × 139H × 215D mm (approx.4.3kgs)
0GE00002 1m, red
0GE00001 1m, black
Power cord (1)
Electrodes : refer to P-61
22
AUTOMATIC INSULATION / WITHSTANDING HiTESTER
Programmable testing, full remote control
Automatic Insulation Withstanding Tester
●Insulation resistance test (DC50V~1200V), Withstanding voltage test
(AC/DC5000V), full remote control in series
●Programmable testing
(Testing Programs 32 files, Testing points 50 steps/file)
●Accurate testing voltage generation by PWM control method
●HIGH VOLTAGE SCANNER 3930 (Option)
3153
SPECIFICATIONS
�Withstanding test
Testing voltage
AC 0.2 to 5.00 kV 500VA (maximum 30 minutes)
DC 0.2 to 5.00 kV 50VA (continuous)
Voltage setting method Digital setting
Sin wave
Waveform
50/60Hz DC
Frequency
Current: 0.01 to 100.0 mA, ±(2% rdg. +5dgt.)
Measurement range
10mA/100mA(AC)
AC (Average value rectified, RMS display)
�Insulation test
Testing voltage
DC50 to 1200V
0.1 to 9999MΩ, 4 ranges
Measurement range
Contents: UPPER-FAIL / PASS / LOWER-FAIL
Judgment function
(Digital setting window comparator method)
Setting range: 0.3 to 999 seconds
Timer section
EXT I/O, EXT SW, RS-232C, GP-IB
Interfaces
Fluorescent tube display (digital), Analog meter
Display
Output voltage, detection current, Insulation resistance
Monitor function
AC100-120V/AC200-240V, (50/60 Hz), 1000VA max.
Power supply
320W×155H×480D mm, 18 kg
Dimensions, mass
H.V. TEST LEAD (high voltage side and return, 1 each) 9615,
Accessories
Power cord (1), spare fuse (1)
Electronic Measuring Instruments
OPTIONS
3930
STANDARD
STANDARD
REMOTE CONTROL BOX (single)
REMOTE CONTROL BOX (dual)
HIGH VOLTAGE SCANNER
SAFETY TEST DATA MANAGEMENT
SOFTWARE
RS-232C CABLE
(Dsub 9pin-9pin, cross,1.8m)
RS-232C CABLE
(Dsub 9pin-25pin,cross,1.8m)
GP-IB CONNECTOR CABLE (2m)
GP-IB CONNECTOR CABLE (4m)
INSULATION / WITHSTANDING HiTESTER
Perform insulation resistance and withstand
voltage testing in a single series
●Insulation resistance test (DC500V/1000V)
●Withstanding voltage test (AC5000V)
●Testing in series
(Insulation resistance test to Withstanding voltage test )
●Standard Interfaces (EXT I/O, EXT SW, RS-232C, STATUS OUT)
9613
9614
3930
9267
9637
9638
9151-02
9151-04
3159
SPECIFICATIONS
�Withstanding test
Testing voltage
0 to 2.5 kV / 0 to 5.0 kV AC, dual-range configuration
(Average value rectified, effective value display)
500 VA (maximum 30 minutes)
Voltage setting method Manual adjusted transformer
Waveform
Same as the power supply waveform
Frequency
Same as the power supply frequency
Measurement range
Current: 0.01 to 120 mA , ±(3% f.s.+20µA)
2mA/8mA/32mA/120mA
AC (Average value rectified, RMS display)
�Insulation test
Testing voltage
DC500V/1000V
Measurement range
2MΩ to 2000MΩ(500V), 4MΩ to 2000MΩ(1000V)
Judgment function
Contents: UPPER-FAIL / PASS / LOWER-FAIL
(Digital setting window comparator method)
Timer section
Setting range: 0.5 to 999 seconds
Interfaces
EXT I/O, EXT SW, RS-232C
Display
Fluorescent tube display (digital), Analog meter
Monitor function
Output voltage, detection current, Insulation resistance
Power supply
120 V AC, 50/60 Hz (3159-01)
220 V AC, 50/60 Hz (3159-02)
230 V AC, 50/60 Hz (3159-03)
240 V AC, 50/60 Hz (3159-04)
Dimensions, mass
320W×155H×330D mm, 18 kg~21.5kg
Accessories
H.V. TEST LEAD (high voltage side and return, 1 each) 9615,
Power cord (1), spare fuse (1)
OPTIONS
STANDARD
23
SAFETY TEST DATA
MANAGEMENT SOFTWARE
9267
REMOTE CONTROL BOX (single)
REMOTE CONTROL BOX (dual)
RS-232C CABLE
(Dsub 9pin-9pin, cross,1.8m)
RS-232C CABLE
(Dsub 9pin-25pin,cross,1.8m)
SAFETY TEST DATA MANAGEMENT
SOFTWARE
9613
9614
9637
9638
9267
3173
PORTABLE WITHSTANDING VOLTAGE HiTESTER
An Economical and Simple way to Handle
Withstand Voltage Testing
●Measures between 0 to 3kV AC
●External Control (Standard)
SPECIFICATIONS
Basic Specifications
[Voltage generator]
Output voltage range
0 to 3 kV AC (single range), 30 VA
Accuracy
±5% f.s.
Waveform
Power waveform, Synchronized to power
[Current detector]
Current cut-off
0.1 to 9.9 mA
Current cut-off accuracy Setting value ±(5%+0.05mA)
Evaluation method
Analog comparator PASS, FAIL a buzzer sound and external I/O
[Timer area]
Setting range
1 to 99 sec (1-second resolution)
Timer accuracy
Setting value ±(1%+50msec)
General Specifications
EXT I/O signal
START and STOP, PASS and FAIL, TEST
Power supply
120 V AC (3173-01), 220 V AC (3173-02)
230 V AC (3173-03), 240 V AC (3173-04) 50/60 Hz 50 VA
Dimensions, Mass
Approx. 149 (W) × 200 (H) × 215 (D) mm
Approx. 7.0 kg (for 120 to 240 V AC)
Power cord, spare fuse, H.V. TEST LEAD 9615 (1)
Accessories:
PORTABLE WITHSTANDING VOLTAGE HiTESTER (100 V AC)
PORTABLE WITHSTANDING VOLTAGE HiTESTER (120 V AC)
PORTABLE WITHSTANDING VOLTAGE HiTESTER (230 V AC)
PORTABLE WITHSTANDING VOLTAGE HiTESTER (240 V AC)
●Measures between 0 to 5kV AC
SPECIFICATIONS
Test function
Testing voltage
Voltage testing method
Transformer capacity
Voltage adjustment
Waveform
Frequency
Measurement items
Judgment function
STANDARD
Timer section
Interfaces
Display
Monitor function
Power supply
Dimensions, mass
Accessories
Withstanding test
0 to 2.5kV / 0 to 5.0kV AC, dual-range configuration
Zero-toggle switch
500VA (maximum 30 minutes)
Manually adjusted transformer
Same as the power supply waveform
Same as the power supply frequency
Voltage: 0 to 5kV AC (Average value rectified, RMS display)
Current: 0.01 to 120mA AC (Average value rectified, RMS display)
Contents: UPPER-FAIL / PASS / LOWER-FAIL
(Digital setting window comparator method)
Setting range: 0.5 to 999 seconds
EXT I/O, EXT SW, RS-232C
Fluorescent tube display (digital), Analog meter
Output voltage, detection current
120V AC, 50/60Hz (3158-01) 220V AC, 50/60Hz (3158-03)
230V AC, 50/60Hz (3158-04)
320W × 155H × 263D mm, 16kg (3158-01), 18kg (3158-03, -04)
H.V. TEST LEAD (high voltage side and return, 1 each) 9615, Power cord (1), spare fuse (1)
AC WITHSTANDING VOLTAGE HiTESTER (120V AC)
AC WITHSTANDING VOLTAGE HiTESTER (220V AC)
AC WITHSTANDING VOLTAGE HiTESTER (230V AC)
AC WITHSTANDING VOLTAGE HiTESTER (240V AC)
Electronic Measuring Instruments
3158
AC WITHSTANDING VOLTAGE HiTESTER
Guarantees electrical and electronic equipment safety
3173
3173-01
3173-03
3173-04
3158-01
3158-03
3158-04
3158-05
OPTIONS
REMOTE CONTROL BOX (SINGLE)
REMOTE CONTROL BOX (DUAL)
RS-232C CABLE (1.8 m) (9pin-9pin/Cross)
RS-232C CABLE (1.8 m) (9pin-25pin/Cross)
SAFETY TEST DATA MANAGEMENT SOFTWARE
DIGITAL MΩ HiTESTER
For the laboratory to the production line, six test
voltages from 25 to 1000V
9613
9614
9637
9638
9267
3154
SPECIFICATIONS
Measurement function Insulation resistance (Applied DC voltage method)
25, 50, 100, 250, 500, 1000 V DC
Testing voltage
Measurement range 25 to 50 V: 2MΩ to 200 MΩ, 3 ranges
100 to 250 V: 2MΩ to 2000 MΩ, 4 ranges
500 to 1000 V: 2MΩ to 4000 MΩ, 4 ranges
±2 % rdg. ±5 dgt. (at 25 to 100 V testing voltage, 0 to 20.00 MΩ)
Accuracy
(at 250 V testing voltage, 0 to 100.0 MΩ) (at 500 to 1000 V testing
voltage, 0 to 999 MΩ)
±5 % rdg. (at 25 to 50V testing voltage, 19.0 to 200.0MΩ)
(at 100V testing voltage, 19.0 to 2000MΩ) (at 250V testing voltage,
100.1 to 2000MΩ) (at 500 to 1000V testing voltage, 1000 to 4000MΩ)
Fast: less than 0.7 second, Slow:less than 1.5 seconds (at manual ranging)
Response times
Fast: 10 samples/s, Slow:1 sample/s
Sampling rates
Comparator functions: judgments PASS or FAIL Test time timer
Functions
functions: 0.5 to 99 second Delay time timer functions: 0.1 to 99 second
LED
Display
100 to 240 V AC (50/60 Hz)
Power supply
215W × 61H × 213D mm, 1.1 kg
Dimensions, mass
Power cord (1)
Accessories
OPTIONS
STANDARD
TEST LEAD
TEST PROBE
SWITCHED PROBE
RS-232C CABLE (1.8 m) (9pin-9pin/Cross)
RS-232C CABLE (1.8 m) (9pin-25pin/Cross)
SAFETY TEST DATA MANAGEMENT SOFTWARE
9185
9294
9299
9637
9638
9267
24
SPECIFICATIONS
3156
LEAK CURRENT HiTESTER
Leakage Current Measurement Essential for
Electrical Safety
●Automatically compatible with Networks
stipulated by IEC/UL/JIS standards
●Automatic measurement function
(Measuring power supply polarity
switching as well as the normal state /
single failure state)
●Stores data for 100 units
●Power supply separation
Electronic Measuring Instruments
STANDARD
STANDARD
SPECIFICATIONS
Earth leakage current
Measurement mode
Leakage current between enclosure and earth /
Leakage current between enclosure and enclosure /
Leakage current between enclosure and line /
Patient leakage current I / Patient leakage current II /
Patient leakage current III / Patient auxiliary current
DC / AC / AC+DC (25mA max), AC peak (75mA max)
Target current
Measurement range DC / AC / AC+DC mode ; 50µA / 500µA / 5 mA / 25 mA
AC peak mode ; 500µA / 1 mA / 10 mA / 75 mA
Measurement system Indication of a current value calculated based the measured drop in
voltage caused by simulated resistance of the human body.
Measurement of true effective value.
The measurement section ; chassis-grounded and floating.
DC / AC / AC+DC mode ; ±(2.0 % rdg. + 6 dgt.)
Accuracy
AC peak mode ; ±(2.0 % rdg. + 2 dgt.)
DC mode ; ±(2.0 % rdg. + 3 dgt.)
1 MΩ ±1 % (Excluding voltmeter section, simulated resistance
Input resistance
of the human body)
For medical electrical equipment / For IEC 60990 /
Network (human
simulated resistance) For JIS / For UL / General-purpose 1 / General-purpose 2
110 % voltage application function / Wiring check function /
Functions
Automatic measurement function /
Application line selection function /
Ground fault prevention function /
Functions
Interface
Power supply
Dimensions, mass
Accessories
OPTIONS
RS-232C CABLE (9-pin to 9-pin, crossing cable 1.8m)
RS-232C CABLE (9-pin to 25-pin, crossing cable 1.8m)
GP-IB CABLE (2.0m)
GP-IB CABLE (4.0m)
PRINTER
AC ADAPTER (for printer, for use in EU)
AC ADAPTER (for printer, for use in USA)
CONNECTION CABLE (for printer)
RECORDING PAPER (for printer)
CARRYING CASE (with casters)
SAFETY TEST DATA MEASUREMENT SOFTWARE
AC GROUNDING HiTESTER
Protective ground tester indispensable for
standard certification
Setting of single-fault condition /
Switching power supply polarity / Setting of measuring time /
Measurement delay / Maximum value hold /
Allowable value judgement / Data save / Clock / Data back up / etc.
EXT I/O , RS-232C , GP-IB
100, 120, 220, 240 V AC (default setting)
(50/60 Hz, Rated power ; 30VA)
Approx. 320W × 110H × 263D mm, 4.0 kg
TEST LEAD 9170(2), ENCLOSURE PROBE 9195(1),
CARRYING CASE 9399(1), Alligator clip(3)(2 red, 1 black)
AC Power cord(2), Spare fuse(2)
3157-01
SPECIFICATIONS
Low resistance, AC 4-terminal method
Measurement items
Current generator principle: PWM constant current control,
Generator section
Current setting range: 3.0A to 31.0A (0.1A resolution), into 0.1Ω load,
Maximum output power: 130VA (at output terminals)
Subject to derating according to ambient temperature (80% at 40°C)
Frequency: 50Hz or 60Hz sine wave
Soft start function: Apply current only after checking load connection
Resistance measurement: 0 to 1.800Ω (0.001Ω resolution), Accuracy:
Monitor section
±2% rdg. ±4 dgt. (after zero-adjust), Current monitoring range: 0 to
35.0A AC (0.1A resolution), Monitoring cycle: 2 times/second
Timer setting: Counts down time after start until preset time, or
Other functions
shows elapsed time after start, Setting range: 0.5 to 999 second,
Comparator: Pass/Fail evaluation using preset upper/lower limit, I/O
output, Memory function: max. 20 settings (with save/load)
Fluorescent tube digital display
Display
100 to 120V, 200 to 240V AC (auto-switching), 50/60Hz
Power supply
320W × 90H × 263D mm, 7kg
Dimensions, mass
Power cord(1), Spare fuse(1), Shorting bar(2)
Accessories
OPTIONS
OPTION
25
OPTION
9637
9638
9151-02
9151-04
9442
9443-02
9443-03
9444
1196
9686
9267
CURRENT PROBE
CURRENT APPLY PROBE
GP-IB CONNECTOR CABLE (2m)
GP-IB CONNECTOR CABLE (4m)
GP-IB INTERFASE
9296
9297
9151-02
9151-04
9518-02
SIGNAL SOURCE
7016
Signal Generator with DMM
SPECIFICATIONS
Constant voltage: 0 to ±1.5V, 100µV resolution, 0 to ±15V,
1mV resolution,Sink/source: ±25mA, ±0.03%of setting ±3dgt.
Constant current: 0 to±25mA,1µ A resolution,
Sink/source:±12V, ±0.03% of setting ±5dgt.
Pulse signal genration:0.5to 4800Hz, 28 ranges, ±0.005% of
setting ±0.01Hz
Measurement functions DC Voltage: 50mV to250V, 6 ranges, ±0.03% rdg. ±5dgt.
AC Voltage: 50mV to250V, 6 ranges, ±0.7% rdg. ±20dgt.
and Basic accuracy
AC+DC Voltage: 50mV to250V, 6 ranges, ±0.8% rdg. ±25dgt.
DC Current: 50 to 500mA, 2 ranges, ±0.03% rdg. ±5dgt.
AC Current: -50to 500mA, 2 ranges, ±0.6% rdg. ±20dgt.
AC+DC Current: 50 to 500mA, 2 ranges, ±0.7% rdg. ±40dgt.
Measurement functions Resistance: 500Ω to50MΩ, 6 ranges, ±0.15% rdg. ±5dgt.
Diode&Continuity check: Possible
and Accuracy
Temperature :-40to1372°C, ±0.3%rgt. ±3°C
(K type thermocouple, °F display possible)
Frequency :100Hz to 200kHz, 5 ranges, ±0.02% rdg. ±3dgt.
LCD with backlignt 51,000 counts
Display
LR6(AA)×8, included Ni-MH battery pack, or
Power supply
included AC adapter
90W×192H×54D mm, 735g(instrument only)
Dimensions,mass
Carrying case(1), AC adapter(1), Battery(8), TEST LEAD 3851
Accessories
(1), Alligator clips(1), Yellow test lead(1), Test leads(1)
Generator functions
and Accuracy
●Constant voltage 0 to ± 1.5000V 0 to ± 15.000V
●Constant current 0 to ± 25.000mA
●Pulse generation and measurement
STANDARD
OPTIONS
COMMUNICATION PACKAGE(RS-232C)
COMMUNICATION PACKAGE(USB)
SHEATH TYPE TEMPERATURE PROBE
SURFACE TYPE TEMPERATURE PROBE
SHEATH TYPE TEMPERATURE PROBE
SHEATH TYPE TEMPERATURE PROBE(class1)
SHEATH TYPE TEMPERATURE PROBE(class1)
SHEATH TYPE TEMPERATURE PROBE(class1)
SHEATH TYPE TEMPERATURE PROBE(class1)
SHEATH TYPE TEMPERATURE PROBE(class1)
SURFACE TYPE TEMPERATURE PROBE
TEST LEAD (Lead length:1m/standard accessories)
*Non-CE mark products
3856-01
3856-02
*9180
*9181
*9182
*9183
9472
9473
9474
9475
9476
3851-10
7011
All-in-one Signal source
SPECIFICATIONS
Constant voltage: 0 to ±2.5 V, 100µV resolution,
0 to ±25 V, 1 mV resolution, Sink /source: ±25 mA,
±0.03% of setting ±3 dgt.
Constant current: 0 to ±25 mA, 1µA resolution,
Sink /source; ±25 V, ±0.03 % of setting ±3 dgt.
Thermoelectric power TC (0°C)/TC(RJ)
K: -176.0 to 1372.0°C, E: -220.0 to 839.0°C, J: -208.0 to
1108.0°C, T: -169.0 to 400.0 °C, R: -50 to 100°C, 101 to
1769°C, S: -50 to 100°C, 101 to 1769°C, B: 300 to 600°C,
601 to 1820°C
±0.05% of setting ±0.5°C (at Thermoelectric power K)
Basic Accuracy
Measurement functions Voltage: 0 to ±2.5 V, 100µV resolution,
0 to ±25 V, 1 mV resolution, Input resistance: 1 MΩ,
and Accuracy
±0.03% rdg. ±2 dgt.
Current: 0 to ±25 mA, 1µA resolution,
Input resistance: 25Ω, ±0.03 % rdg. ±2 dgt.
-25.0 to 80.0°C, 0.1°C resolution (using the 9184)
Temperature
100Ω, ±0.2 % rdg.
Standard resistance
LR6(AA)×6, 9420 BATTERY PACK(Ni-Cd),
Power supply
or 9418-10 AC ADAPTER
104W×180H×58D mm, 590 g (excluding batteries)
Dimensions, mass
INPUT CORD 9168(1), TEST LEAD 9170(1), Fuse(3)
Accessories
Generator functions
and Accuracy
●Check thermocouple temperature sensors
●Generate various signals for electronic circuit and equipment testing
●Calibrate industrial equipment all with a single unit
OPTIONS
RJ SENSOR
9184
(for reference contact compensation)
CARRYING CASE
9380
AC ADAPTER
9418-10
BATTERY PACK (7.2V /700mAh) 9420
WAVEFORM GENERATOR
Arbitrary waveform generator with four
independently controllable channels
●Even for complex signals, evaluation is made easy
●Easy touch panel operation
●Multiple channels, 4CH (7075), 2CH (7075-01)
●Large 128,000-Word/channel memory, sweep sequence functions
STANDARD
STANDARD
Electronic Measuring Instruments
DC SIGNAL SOURCE
7075 7075-01
SPECIFICATIONS
Number of channels 7075: 4-channels, 7075-01: 2-channels
Function generator, Arbitrary waveform generator (for each channel)
Output functions
Max. output voltage 10 V range: 10 mV to 10 V o.c. (1 mV resolution)
1 V range: 1 mV to 1 V o.c. (0.1 mV resolution)
0.1 V range: 0.1 mV to 0.1 V o.c. (0.01 mV resolution)
(o.c.:open-circuit)
40 Ohm
Minimum load
impedance
50 Ohm±2 % (DC)
Output impedance
Waveform types: sine, square (fixed 50 % duty), triangle, ramp-up,
Function generator
ramp-down, pulse, noise, DC, Frequency range:sine (10 mHz to
mode
10 MHz), square (10 mHz to 10 MHz), triangle (10 mHz to
200 kHz), pulse (10 mHz to 200 kHz)
Arbitrary waveform Voltage axis resolution: 16 bits (64000 counts)
Waveform memory capacity: 128 kW/ch
generation mode
Filtering: 2-stage LPF, 50 Hz to 1 MHz, 14 steps,
Waveform input methods: FD/GP-IB (direct download from
MEMORY HiCORDER by FD or GP-IB), or RS-232C download
(at use of 7990), Arbitrary waveform clock: Max. 4ch,
Frequency range: 10 mHz to 10 MHz (10 mHz resolution)
5.7-inch LCD (with touch panel)
Display
FDD×1, MS-DOS format
Data storage
100/120/200/230 V AC/auto selects, (50/60 Hz)
Power supply
345W×130H×286Dmm, 7075: 7.8 kg, 7075-01:7.5 kg
Dimensions, mass
WAVEFORM CREATION SOFTWARE (CD-R×1) 7990
Accessories
OPTIONS
●Output cord
CONNECTION CORD BNC to BNC, 1.5 m length 9165
CONNECTION CORD BNC to clip, 1.5 m length 9166
●PC communication
GP-IB CONNECTION CABLE 2 m length 9151-02
GP-IB CONNECTION CABLE 4 m length 9151-04
26
Environmental Measuring Instruments
Environmental Measuring Instruments Index
Temperature measurement
3441/3442
-100 °C to 1300 °C
Choose from Basic or
Waterproof models
Rotation, Illumination
3446-01, 3447-01 3412-50
-100˚C to 1000˚C 1 ch (3446) -50 °C to 999 °C
-100˚C to 300˚C 2 ch (3447) With analog output
with built-in memory
. . . . . . . . . . . . . . . p.30
3403 Rotation
3423 Illumination
30 to 100,000 r/min
20 to 200,000 lx, digital
3404 Rotation
30 to 100,000 r/min,
Max. /Min. /Total /Period
. . . . . . . . . . . . . . . p.53 . . . . . . . . . . . . . . . p.30
Non-contact temperature measurement
Environmental Measuring Instruments
3415-01
-50 °C to 500 °C
Two-beam laser marker
Narrow field
measurement
3416-01
-50 °C to 500 °C
LED spot marker
Spot measurement
3418
-50 °C to 500 °C
Without laser marker
Narrow field
measurement
3443
-50.0 °C to 500.0 °C
Two-beam laser marker
Narrow field measurement
Data memory, Memory dump to
printer, RS-232C interface
. . . . . . . . . . . . . . . p.30
3470
Magnetic field tester for
home appliances
. . . . . . . . . . . . . . . p.56
(via infrared radiation energ y)
3444
-50.0 °C to 500.0 °C
Two-beam laser marker
Narrow field measurement
MAX. MIN. indication, Analog
output, RS-232C interface
. . . . . . . . . . . . . . . p.30
3445
-50.0 °C to 500.0 °C
Two-beam laser marker
Spot measurement
MAX. MIN. indication, Analog
output, RS-232C interface
. . . . . . . . . . . . . . . p.30
Data Loggers (Temperature/Humidity/Instrumentation/DC-Voltage/AC-Current/AC-Voltage/Leak-Current)
2300 Series
Remote Measurement System
Various measurement modules
Internal memory
LAN or SS Air Module
. . . . . . . . . . . . . . . p.28
3641-20,3632-20,3633-20 3634-20
Temperature/Humidity
-40~85˚C 0~100% rh
(using the 9680 sensor)
-40.0 °C to 180.0 °C
(external sensor)
. . . . . . . . . . . . . . . p.29
Instrumentation
0 to 20.00 mA DC
3635-24,-25,-26
DC Voltage
-24: ±500.0 mV DC
-25: ±5.000 V DC
-26: ±50.00 V DC
. . . . . . . . . . . . . . . p.29
. . . . . . . . . . . . . . . p.29
Data Loggers (Pulse/Illumination/DC-Voltage/Communication Base)
27
Magnetic Field
HiTESTER
3639-20
Pulse Totalizer
9,999counts/interval
(1ch)
3640-20
. . . . . . . . . . . . . . . p.29
. . . . . . . . . . . . . . . p.29
Illumination
2000/20000/200000 lx
(1ch)
3645-20
Multi-range
Voltage Logger
with preheat
signal function
. . . . . . . . . . . . . . . p.29
3911-20,3912-20
Communication Base
to analyze and process
on a personal computer
. . . . . . . . . . . . . . . p.29
3636-20
AC Current (2ch)
0 to 50.00/500.0 A AC
3637-20
AC Voltage (1ch )
0 to 600.0 V AC
. . . . . . . . . . . . . . . p.29
2D Thermo Testing
3460-50
64-element thermopile
array sensor
Transfer data to PC via
RS-232C
. . . . . . . . . . . . . . . p.30
3638-20
AC Leak Current
(2ch) with clamp-on leak
sensor
. . . . . . . . . . . . . . . p.29
REMOTE MEASUREMENT SYSTEM
Easily Construct a Centralized Data Management
System for Monitoring Multiple Locations
LAN Module that paves the way for a low cost remote measuring
system by utilizing existing data network
2300 Series
●Various measurement modules for temperature and humidity,
instrumentation, and pulse
●Power measurement module for multiple circuits
●Large internal memory to prevent data loss due to
communication problems
●Communication module with built-in real-time clock tracks the
data of each measurement module to the second
●SS Air Module for constructing wireless systems
Environmental Measuring Instruments
2343-20
2353-20
HUMIDITY MODULE 2301-20
Temperature 1ch and humidity 1ch.
Use with optional sensor 9764
Temperature: -40.0 to 85.0°C
Humidity: 0.0 to 100%RH
Pt MODULE 2302-20
Temperature 2ch (Pt100)
2 types of platinum resistance thermo sensors available
TC MODULE 2303-20
2ch temperature measurement using thermocouples
(K, E, J, T). 4 TC types available
PULSE MODULE 2304-21
For 2ch pulse input (voltage, contact), maximum 16M pulses/
interval
Input pulse: 4kHz max. (voltage/electronic contact signal)
25Hz max. (mechanical contact signal)
INSTRUMENTATION MODULE Voltage / current 2ch measurement, for 4-20mA, 1-5V
instrumentation signals
2305-20
POWER METER
MODULE 2331-20
For single circuit power measurement.
Single-phase 2-wire to 3-phase 4-wire
Voltage: AC 100/200V
Current: AC 5A (with CLAMP ON SENSOR 9695-02), AC
50A (with 9695-02), AC 100A
(with 9695-03 or 9661-01), AC 500A (with 9661-01)
POWER METER
MODULE 2332-20
For multiple circuit power measurement: from 6 circuits of
single-phase 2-wire to 3 circuits of 3-phase 3-wire installations
Voltage: AC200V (100V accepted at 200V range)
Current: AC 5A (with CLAMP ON SENSOR 9695-02), AC
50A (with 9695-02), AC 100A (with
9695-03 or 9661-01), AC 500A (with 9661-01)
*3-phase 4-wire circuit cannot be measured
INPUT MODULE 2341-20
For recording the status of contact signals
Input 8 ch, Input internal bus isolated
Easily capture on/off status with LED
OUTPUT MODULE 2342-20
Acts as receiver of higher order external control device,
outputs control signals and monitors data of measurement
modules
Output 8ch (Open corrector output), Output internal bus isolated
RS LINK MODULE 2343-20
For communicating with RS-232C interface equipped instruments
Interface: RS-232C, Transfer speed: 57.6kbps(max.)
Please inquire regarding compatible instruments.
(Existing compatible HIOKI instruments include
Models 3331 and 3332.)
AIR MODULE 2351
2.4GHz band SS radio system (RS-232C equipped)
Transfer speed: 51.9kbps(fixed), RS-232C: 57.6kbps(max.)
2351-20 : For EU
2351-21 : For USA
WIRE MODULE 2352-20
For small-scale measurement systems or built-in use
Interface: RS-232C, Transfer speed: 57.6kbps(max.)
LAN MODULE 2353-20
For data logging via LAN
Interface: 10BASE-T
AC POWER MODULE 2361-20 Power supply for the communication modules and
measurement modules (max. 10 modules)
Input: AC 100 to 240V, Output: DC5V/2.4A
DC POWER MODULE 2362-20 Power supply for the communication modules and
measurement modules (max. 10 modules)
Input: DC 19 to 36V, Output: DC5V / 2.4A
MODULE BASE 2391
For connecting modules (3 slots reserved for power supply
and communication module)
2391-01: For relay and master station,
2391-02: 5 measurement module slots,
2391-03: 10 measurement module slots
*Model 2331 uses 2 slots
MODULE BASE 2392
For connecting MODULES (also connects with additional
MODULE BASEs for increased measurement capabilities)
2392-01: 1 slot; includes power and internal bus
connection terminal
2392-02: 2 slots; connect with 2391-01 for additional
measurement module slots
* POWER MODULE not compatible; must use with
Model 2392-01 to access POWER MODULE
28
3630
Data Loggers
Data Loggers for All Types of Measurements
For HACCP-related Temperature and Humidity Recording
HUMIDITY LOGGER
TEMPERATURE LOGGERs
For Recording Voltage
VOLTAGE LOGGERs
3641-20
3632-20
3633-20
3635-24, -25, -26
3645-20
3637-20
Can alternately record temperature
and humidity on two channels
for temperature and humidity
measurement
-40.0 ˚C to 85.0 ˚C
0.0 %rh to 100.0 %rh
Waterproof with built-in sensor for
temperature measurement
-20.0 ˚C to 70.0 ˚C
External sensor for temperature
measurement
-40.0 ˚C to 180.0 ˚C
For measurement DC voltage
-24: ± 500.0 mV DC
-25: ± 5.000 V DC
-26: ± 50.00 V DC
With preheat function
For measuring DC voltage
Range: ± 50.00 mV to
± 50.00 V DC
For measuring AC voltage
Range: 600.0 V AC
For Recording Precipitation or Illumination
For Recording Load Current and Monitoring Leak Current
ILLUMINATION
LOGGER
PULSE LOGGER
INSTRUMENTATION LOGGER CLAMP LOGGER
LEAK LOGGER
3639-20
3640-20
3634-20
3636-20
3912-20: OPTION
3638-20
3911-20: OPTION
For cumulative pulse measurement
for precipitation gauges,
flow gauges, etc.
For illumination measurement
Range: 2,000 lux to
200,000 lux
For measuring typical
instrumentation signals
Range: 20.00 mA DC
Environmental Measuring Instruments
For measuring alternating current on
two channels
Range: 50.00/500.0 A AC
(Clamp sensors sold separately)
For measuring alternating current on
two channels
Range: 100.0/1000 mA AC
(Clamp sensors sold separately)
Accessories
HUMIDITY SENSOR 9680
Cord length: 1 m
CONNECTION CABLE 9632
Cord length: 1 m
Options for 3634-20
CONNECTION CORD 9639
Cord length: 3 m
CONNECTION CABLE 9629
Cord length: 5 m
Options for 3636-20
CONNECTION CABLE 9633
Cord length: 1 m
CONNECTION CABLE 9634
Cord length: 1 m
CLAMP ON SENSOR 9650
AC 100 A f.s./Up to φ 15 mm
Cord length: 3 m
LUX SENSOR 9662
Cord length: 2 m
Options for 3638-20
CLAMP ON SENSOR 9651
AC 500 A f.s./Up to φ 46 mm
Cord length: 3 m
CLAMP ON SENSOR 9657
CLAMP ON SENSOR 9658
TEMPERATURE SENSOR
(Molded plastic type)
9631-05
TEMPERATURE SENSOR
(Lug type)
9631-04/9631-14/9631-24
AC 1.0 A f.s. / Up to φ 40 mm
Cord length: 3 m
AC 1.0 A f.s. / Up to φ 12 × 30 mm
Cord length: 3 m
Options for 3641-20 / 3633-20
HUMIDITY SENSOR (for 3641-20)
9680/9680-01/9680-02
-40.0 ˚C to 85.0 ˚C
0.0 %rh to 100.0 %rh
Cord length:9680:1 m (provided),
9680-01: 5 m, 9680-02:10 m
TEMPERATURE SENSOR
(Molded plastic type)
9631-01/9631-11/9631-21
-40.0 ˚C to 180.0 ˚C
Cord length:9631-01:1 m,
9631-11: 5 m, 9631-21:10 m
TEMPERATURE SENSOR
(Needle type)
9631-02
-40.0 ˚C to 120.0 ˚C
Cord length:1 m
COMMUNICATION BASE
Analyze and Process Data on a Personal Computer
The 3911-20, 3912-20 COMMUNICATION BASE are
used to transfer data to a personal computer.
3911-20
3912-20
3911-20
TEMPERATURE SENSOR
(Sheathed type)
9631-03
-40.0 ˚C to 120.0 ˚C
Cord length:1 m
-40.0 ˚C to 180.0 ˚C
Cord length:30 mm
-30.0 ˚C to 180.0 ˚C
Cord length:9631-04:1 m,
9631-14: 5 m, 9631-24:10 m
3911-20 3912-20
3911-20, 3912-20
Recording Capacity
Communication
method
Power supply
Dimensions
and mass
Accessories
: SPECIFICATIONS
Max. 16,000 data points × 16 ch, 32,000 data points × 8 ch,
RS-232C (3911-20 to a PC)
USB 1.1 (3912-20 to a PC)
4 × 1.5 V, LR03 (AAA) alkaline dry cell batteries
3911-20: 69W×92H×36D mm, 150g (including batteries)
3912-20: 69W×128H×36D mm, 180g (including batteries)
3911-20: LR03 (AAA) alkaline dry cell batteries (4),
Communication software (1)
3912-20: USB cable (1), LR03 (AAA) alkaline dry cell batteries (4),
Communication software (1)
Options for 3911-20
3912-20
29
Communication software included
with the 3911-20, 3912-20
Compatible OS: WIndows 95/98/
NT4.0/Me/2000/XP
CABLE 9637 RS-232C
9-pin to 9-pin crossed
cable/1.8 m
RS-232C CABLE 9638
9-pin to 25-pin
crossed cable/1.8 m
TEMPERATURE HiTESTER
Supports
temperature
management
demands of various
applications
3442
(Waterproof construction)
3441
TEMPERATURE HiTESTER
Non-contact measurement, quick and easy
temperature management
3441 3442
3441, 3442 : SPECIFICATIONS
Material type
K type thermocouple (Chromel /Alumel)
Measurement range -100°C to 1300 °C (-148°F to 2372°F)
The actual measurement range is restricted by the temperature probe.
0.1°C*1 or 1°C*2
Resolution
Unit Accuracy
±0.1%rdg. ±0.8°C (1.5 °F)*1 or ±0.2% rdg. ±1°C (1.8°F)*2
(in addition to accuracy of temperature sensor)
*1 during measurement from -100 to 199.9°C (-148°F to 392°F)
*2 during measurement from 200 to 1300°C (392°F to 2372°F)
Display
LCD
Sampling rate
2 times/second
Contact compensation Auto compensation
Functions
Max/Min temperature recording and display,
display data hold, sensor discontinuity display,
Over-range display, °C/°F display switching (3441-02, 3442-03),
auto power save, low battery warning
Place of use
Indoor use to altitude of 2000 m
Power supply
R6P (AA)×4, or LR6 (AA)×4
Operating time
200 hours or better of continuous use (with manganese battery)
Dimensions, mass
74W×155H×24D mm, 160 g
Accessories
Strap band(1), R6P(AA) Batteries(4)
3443 3444 3445
3443 : SPECIFICATIONS
Measurement range
Measurement field diameter
Accuracy
3444, 3445 : SPECIFICATIONS
Measurement range
Measurement field diameter
Accuracy
3443
3444
LUX HiTESTER
3445
3423
Digital illumination meter,
maximum scale of 199,900 lx
2D THERMO HiTESTER
Response time
Date memory function
Analog output function
Interface
Other functions
Power supply
Operating time
Dimensions, mass
Accessories
-50.0°C to 500.0°C, 0.1°C, 0.1 or 1°C resolution switchable
3444 : 24mm at a distance of 1 m
3445 : 2.5mm at a distance of 7 cm
±1 % rdg. (at 200.1 to 500.0 °C), ±2°C (at 0.0 to 200.0 °C),
±10 % rdg. ±2°C (at -50.0 to -0.1 °C)
1.6 sec (95% at 0.1°C resolution), 0.7 sec (95% at 1°C resolution)
None
Possible (requires 3909 INTERFACE PACK)
RS-232C output (requires 3909 INTERFACE PACK)
Auto power save, low battery warning
6F22(006P)× l, or AC adapter
Continuous use of 20 hours (light on) and 50 hours (light off)
47W × 200H × 48D mm, 280 g
Carrying case(1), hand strap(1), 6F22(1), screwdriver(1)
Environmental Measuring Instruments
Response time
Date memory function
Analog output function
Interface
Other functions
Power supply
Operating time
Dimensions, mass
Accessories
-50.0°C to 500.0°C, 0.1°C resolution
24mm at a distance of 1 m
±1 % rdg. (at 200.1 to 500.0 °C), ±2°C (at 0.0 to 200.0 °C),
±10 % rdg. ±2°C (at -50.0 to -0.1 °C)
1.6 seconds (95% response)
130 points of data, memory dump to printer
None
RS-232C output (requires 3909 INTERFACE PACK)
Auto power save, low battery warning, auto-hold
6F22(006P)× l, or AC adapter
Continuous use of 20 hours (light on) and 50 hours (light off)
47W × 200H × 48D mm, 280 g
Carrying case(1), hand strap(1), 6F22(1), screwdriver(1)
3423: SPECIFICATIONS
Measurement range 20 to 200,000 lx full-scale, 5 ranges
Accuracy
±4 % rdg. ±1 dgt. (environment temperature: 23 ±5°C)
Display
1999 full digits, LCD with EL backlight
(Note : in the 20,000 lx range, the maximum is 19990 /10 digits steps,
and in the 200,000 lx range, the maximum is 199900 /100 digits steps)
Response time
5 sec. or less (auto range), 2 sec. or less (manual range)
Receptor element
Silicon photodiode
Other functions
Sensor separate: Permits remote measurement with
the sensor separated from the main unit.(using the 9436)
Analog output: 200 mV DC at full scale rate
Power supply
R6P (AA) × 2 (Continuous use of 25 hours)
or AC adapter (6 V, 300 mA)
Dimensions, mass
74W × 170H × 30D mm, 310 g (including the dry cells)
Accessories
9376 CARRYING CASE(1), Sensor cap(1), R6P(2)
3460-50
SPECIFICATIONS
Thermopile array
Detection element
Measurement range -50 to 1000°C
Approx. 0.2 seconds
Sampling rate
Number of elements 64 (Horizontal 8 x vertical 8)
Transmission type color TFT liquid crystal
Display element
3.8 inch
Display Size
LR6 (AA) alkaline batteries × 6, AC adapter (3915 OPTION PACK)
Power supply
Dimensions and Mass Approx. 165W × 55H × 123D mm (main unit only with the
LCD closed), Approx. 700 g (excluding battery)
LR6 (AA) alkaline batteries x 6, Strap, Compact flash card (16 MB)
Accessories
30
Clamp Sensors
Clamp Sensors Index
Wide-band frequency, high-precision, ideal for observing waveforms (for AC / DC)
3272
3269
3273-50/3276
DC to 50 MHz /
100 MHz
15 A / 30 A maximum
0.1 V / A output
φ 5 mm core jaw dia.
. . . . . . . . . . . . . . p.32
3274
DC to 10 MHz
150 A maximum
0.01 V / A output
φ 20 mm core jaw dia.
. . . . . . . . . . . . . . p.32
3275
DC to 2 MHz
500 A maximum
0.01 V / A output
φ 20 mm core jaw dia.
. . . . . . . . . . . . . . p.32
3272/3269
Power supply for 3273-50,
3274, 3275, 3276
Single sensor (3272)
Four sensors (3269)
. . . . . . . . . . . . . . p.32
9274
DC to 10 MHz
20A rated
2V / 20A output
φ5mm core jaw dia.
9276
DC to 1 MHz
150A rated
1.5V / 150A output
φ20mm core jaw dia.
3270
Power supply &
amplifier for 9274,9276
1V / range output Single
sensor connectable
High-precision sensors to view waveforms or to use with power meters (for AC/DC, or AC only)
9709
Clamp Sensors
DC to 100 kHz
500 A rated
2 V / 500 A output
φ36 mm core jaw dia.
9277
DC to 100 kHz
20 A rated
2 V / 20 A output
φ20 mm core jaw dia.
. . . . . . . . . . . . . . p.33 . . . . . . . . . . . . . . p.33
9278
DC to 100 kHz
200 A rated
2 V / 200 A output
φ20 mm core jaw dia.
9279
DC to 20 kHz
500 A rated
2 V / 500 A output
φ40 mm core jaw dia.
40Hz to 1kHz
10A to 500A range
200mV / range output
φ46mm core jaw dia.
9010-50
. . . . . . . . . . . . . . p.33
9018, 9018-10
40Hz to 3kHz
10A to 500A range
200mV / range output
φ46 mm core jaw dia.
9018-50
. . . . . . . . . . . . . . p.33
5Hz to 50kHz, 20A
rated
2V / 20A output
φ20 mm core jaw dia.
9271
. . . . . . . . . . . . . . p.33 . . . . . . . . . . . . . . p.33 200A rated
2V / 200A output
For power lines (50/60 Hz use)
9010, 9010-10
9270
9132, 9132-10
40Hz to 1kHz
20A to 1000A range
200mV / range output
φ55 mm core jaw dia.
9657-10/9675
9657-10
LEAK CLAMP ON SENSOR
AC 25mV/A Up to φ40mm
9675
LEAK CLAMP ON SENSOR
AC100mV/A Up to φ30mm
9272
10 Hz to 10 kHz
20 or 200 A rated
2 V / 20 or 200 A output
φ46 mm core jaw dia.
9272-10
. . . . . . . . . . . . . . p.33
9555
Power supply for 9270,
9271, 9272, 9277, 9278,
9279
Single sensor connectable
9555-10
. . . . . . . . . . . . . . p.33
Conversion Adapter
9290-10
AC current up to 1500 A,
secondary current 1/10 of
primary, φ55 mm dia. or
88 mm width
Superior phase angle
characteristics
CT-101A
AC current up to 15 A,
secondary current 1/1
or 10 times of primary,
φ25 mm dia.
Clamp Sensors for 3169/3196 Power meters Clamp Sensors for 8205-10/8206-10, 3636-20
9660
45Hz to 5kHz (±1%)
AC current up to 100A
AC 1mV / A output
. . . . . . . . . . . . . . p.34
9694
45Hz to 5kHz (±1%)
AC current up to 5A
AC 10mV / A output
. . . . . . . . . . . . . . p.34
31
9661
45Hz to 5kHz (±1%)
AC current up to 500A
AC 1mV / A output
9667
9669
10Hz to 20kHz (±3dB) 40Hz to 1kHz (2.0%)
AC current up to
AC current up to 1000 A
5000/500A
AC 0.5mV / A output
AC 0.1mV / A, AC
1mV / A output
9650
40Hz to 1kHz (±8%)
AC current up to 100A
Secondary current
100mA AC
9651
40Hz to 1kHz (±3%)
AC current up to 500A
Secondary current
500mA AC
9668
40Hz to 1kHz (±3%)
AC current up to
1000A
Secondary current
1000mA AC
. . . . . . . . . . . . . . p.34 . . . . . . . . . . . . . . p.34 . . . . . . . . . . . . . . p.34 . . . . . . . . . . . . . . p.34 . . . . . . . . . . . . . . p.34 . . . . . . . . . . . . . . p.34
CLAMP ON PROBE
POWER SUPPLY
3273-50 3274 3275 3276
3269/3272
Wide-range current probe allows direct input to oscilloscope
●3273-50/3276: Wide Band from DC to 50/100 MHz, For Large Current
Measurements (30 A rms)
●3274/3275: Wide Band from DC to 10/2 MHz, For Large Current
Measurements (150/500 A rms)
3275
3274
CLAMP ON PROBE : 3276
3273-50
Wide-band model from DC to 100 MHz
SPECIFICATIONS
Output voltage rate
Amplitude accuracy
Noise
Sensitivity temperature
characteristics
Maximum rated
Power supply voltage
Ambient conditions for usage
External magnetic field
resistance
Maximum voltage in
measurement circuit
Measurement conductor
Dimensions and mass
Cable length
Supplied accessories
3273-50
DC to 50MHz (-3dB)
7 ns or less
30A rms
3276
DC to 100 MHz (-3dB)
3.5 ns or less
30A rms
3274
DC to 10MHz (-3dB)
35 ns or less
150A rms
3275
DC to 2MHz (-3dB)
175 ns or less
500A rms
Non-continuous 50A peak
Non-continuous 50 Apeak
Non-continuous 700A peak
0.1V/A
±1.0% rdg. ±1 mV (0 to 30 A)
(DC, 45 to 66Hz)
2.5mA rms or less (measured with
20MHz bandwidth equipment)
Within ±2%
(from 0 to 40°C)
5.6VA
±12V ±0.5V
0 to 40°C, max. 80% rh (no condensation)
Max. 20mA (equivalent)
(DC and 60Hz, Magnetic field of 400A/m)
300V, CAT-I
(insulated conductor)
Diameter max. 5mm
Sensor: approx. 175W×18H×40D mm; 230g
Termination unit: approx. 27W×55H×18D mm
Sensor cable: approx. 1.5 m (BNC connector)
Power cable: approx. 1 m
Soft case 1
0.1V/A
±1.0% rdg. ±1 mV (0 to 30 A)
(DC, 45 to 66 Hz)
2.5mA rms or less (measured with
20MHz bandwidth equipment)
Within ±2%
(from 0 to 40°C)
5.3 VA
±12 V ±0.5 V
0 to 40°C, 80% rh or less (no condensation)
Max. 5 mA (equivalent)
(DC and 60 Hz, Magnetic field of 400 A/m)
300 V, CAT-I
(insulated conductor)
Diameter max. 5 mm
Sensor: approx. 175W×18H×40D mm; 240g
Termination unit: approx. 27W×55H×18D mm
Sensor cable: approx. 1.5 m (BNC connector)
Power cable: approx. 1 m
Hard case 1
Non-continuous 300A peak
500A peak at pulse width of ≤ 30µs
0.01V/A
±1.0% rdg. ±1mV (0 to 150A / DC, 45 to 66Hz)
±2.0% rdg. (150A to 300A peak / DC, 45 to 66Hz)
25mA rms or less (measured with
20MHz bandwidth equipment)
Within ±2%
(At 55Hz/150A input, 0 to 40°C)
5.5VA (Input within the maximum input range.)
±12V ±1V
0 to 40°C, max. 80% rh (no condensation)
Max. 150mA (equivalent)
(DC and 60Hz, Magnetic field of 400A/m)
600 V CAT-II, 300 V CAT-III
(insulated conductor)
Diameter max. 20 mm
Sensor: approx. 176W×69H×27D mm; 500g
Termination unit: approx. 27W×55H×18D mm
Sensor cable: approx. 2 m (BNC connector)
Power cable: approx. 1 m
Hard case 1
● Optional accessories
POWER SUPPLY 3269/3272
Please specify voltage when ordering for use with 120 V, 220 V, or 240 V.
Use the 3269/3272 power supply for general
measurements or when power is not available
from the oscilloscope.
3269
(Four sensors)
0.01V/A
±1.0% rdg. ±5mV (0 to 500A / DC, 45 to 66Hz)
±2.0% rdg. (500A to 700A peak / DC, 45 to 66Hz)
25mA rms or less (measured with
20MHz bandwidth equipment)
Within ±2%
(At 50Hz/500A input, 0 to 40°C)
7.2VA (Input within the maximum input range.)
±12V ±0.5V
0 to 40°C, max. 80% rh (no condensation)
Max. 800mA (equivalent)
(DC and 60Hz, Magnetic field of 400A/m)
600 V CAT-II, 300 V CAT-III
(insulated conductor)
Diameter max. 20 mm
Sensor: approx. 176W×69H×27D mm; 520 g
Termination unit: approx. 27W×55H×18D mm
Sensor cable: approx. 2 m (BNC connector)
Power cable: approx. 1 m
Hard case 1
Clamp Sensors
Frequency bandwidth
Rise time
Continuous maximum
input range
Maximum peak current
3269/3272 SPECIFICATIONS
Suitable sensor model
3273-50, 3274, 3275, 3276 CLAMP ON PROBE
Number of power supply 1 (3272), 4 (3269)
connectors
(connector type: LEMO inc./ FFA..0S.304.CNAC42Z)
Output voltage
±12 V ±0.5 V
Ambient conditions for
0 to 40°C, max. 80%rh (no condensation)
usage
Power requirements
Please specify voltage when ordering for use with 120V,
220V, or 240V.
Maximum rated power
20VA max. (3272)
consumption
170VA max. (3269)
Dimensions and mass
Approx. 73W × 110H × 186D mm; 1.1kg (3272)
Approx. 80W × 119H × 200D mm; 1.2kg (3269)
Power cord×1, spare fuse×1
Supplied accessories
3272
(Single sensor)
CLAMP ON PROBE 3273-50, 3274, 3275, 3276
32
9277 9278 9279
UNIVERSAL CLAMP ON CT
SENSOR UNIT
9555
High-precision sensors to view waveforms
or to use with power meters (for AC/DC)
9277, 9278
●Wide frequency ranges including DC
●Use together with the 9555 SENSOR UNIT for current
waveform monitoring (with a waveform recorder or
oscillograph)
9279
(Non-CE mark product)
9278
9277
SPECIFICATIONS
Rated current
Frequency band width
Accuracy
(DC or 45 to 66 Hz)
Output rate
(with the 9555)
Max. circuit voltage
Core jaw dia.
Power supply
Dimensions, mass
Accessories
9277
20 A AC/DC (continuous 50 A)
DC to 100 kHz (±5 % f.s.)
±0.5 % rdg. ±0.05 % f.s., phase ±0.2°
9278
200 A AC/DC (continuous 350 A)
DC to 100 kHz (±5 % f.s.)
±0.5 % rdg. ±0.05 % f.s., phase ±0.2°
9279 (Non-CE mark product)
500 A AC/DC (continuous 650 A)
DC to 20 kHz (±5 % f.s.)
±0.5 % rdg. ±0.05 % f.s., phase ±0.2°
2 V/rated current range
(waveform output, with the 9555)
600 V peak (insulated wire)
φ20 mm
9555 SENSOR UNIT (required)
176W×63H×34D mm,
430 g, cord length: 3 m
9375 CARRYING CASE (1)
2 V/rated current range
(waveform output, with the 9555)
600 V peak (insulated wire)
φ20 mm
9555 SENSOR UNIT (required)
176W×63H×34D mm,
430 g , cord length: 3 m
9375 CARRYING CASE (1)
2 V/rated current range
(waveform output, with the 9555)
600 V peak (insulated wire)
φ40 mm
9555 SENSOR UNIT (required)
220W×103H×43.5D mm,
860 g , cord length: 3 m
9375 CARRYING CASE (1)
AC/DC CURRENT SENSOR
Measure with Absolute Precision
Clamp Sensors
●High current measurement
●Wide DC to 100kHz frequency range
9709
SPECIFICATIONS
Rated current 500A AC/DC
Output voltage 2V/500A
Maximum input current 700A rms (1000A peak, 50/60 Hz, continuous)
Output resistance 50 Ω
DC < f < 45 Hz :±0.2% rdg. ± 0.02% f.s.
Amplitude
(DC < f < 5 Hz is reference value)
precision
DC, 45 Hz ≤ f < 66 Hz :±0.05% rdg. ±0.01% f.s.
66 Hz ≤ f < 500 Hz :±0.2% rdg. ±0.02% f.s.
500 Hz ≤ f < 5 kHz :±0.5% rdg. ±0.05% f.s.
5 kHz ≤ f < 10 kHz :±2.0% rdg. ±0.10% f.s.
10 kHz ≤ f < 20 kHz :±5.0% rdg. ±0.10% f.s.
20 kHz ≤ f < 100 kHz :±30 % rdg. ±0.10% f.s.
Phase precision DC < f < 45 Hz : ±0.3 deg
(No stipulation for DC accuracy, DC < f < 20
Hz is design value)
45 Hz ≤ f < 66 Hz :±0.2 deg
66 Hz ≤ f < 5 kHz :±0.5 deg
5 kHz ≤ f < 10 kHz :±2.0 deg
10 kHz ≤ f < 20 kHz :±5.0 deg
20 kHz ≤ f < 100 kHz :±30 deg
CLAMP ON PROBE
New & Improved
Temperature
coefficient
Effect of
conductor
position
Effect of external
magnetic field
Effect of magnetization
Maximum rated voltage
against ground
Measurable
conductor diameter
Supply voltage
Power
consumption
Dimensions/
weight
Cord length
Accessories
Amplitude sensitivity: ±0.01% rdg./ºC or less
Offset voltage ±0.005% f.s./ºC or less
±0.05% or less
(when using 100A DC input, and cable with an
external diameter of 10 mm(0.39"))
50mA or less (400A/m, 60 Hz and a DC
magnetic field)
20mA or less (after 500A DC input)
1000V AC/DC (50/60 Hz) (measurement
category III)
36 mm(1.42") or less
DC ±11 V to ±15 V (tracking)
5 VA or less (during 500A DC measurement,
with ±12 V power supply)
160 W(6.30") × 112 H(4.41") ×50
D(1.97")mm, 850 g(30.0oz.)
3 m(9.84ft)
Mark bands (6)
9010-50 9018-50 9272-10 9555-10
9272-10
9010-50
9018-50
40 Hz to 1 kHz
10 A to 500 A range
200 mV / range
output
φ46 mm(1.81 in)
core jaw dia.
40 Hz to 3 kHz
10 A to 500 A range
200 mV / range
output
φ46 mm(1.81 in)
core jaw dia.
33
9555-10
Power supply for the 9277 /
9278 / 9279, and the 9270 /
9271 / 9272 / 9272-10 / 9709
Single sensor connectable
AC ADAPTER 9418-15
*9018/9018-10
*9010/9010-10
40 Hz to 1 kHz
10 A to 500 A range
200 mV / range
output
φ46 mm(1.81 in)
core jaw dia.
*Non-CE mark
1 Hz to 100 kHz
20 or 200 A rated
2 V / 20 or 200 A
output
φ46 mm(1.81 in)
core jaw dia.
9018
9010
9010-10
9018-10
40 Hz to 3 kHz
10 A to 500 A range
200 mV / range
output
φ46 mm(1.81 in)
core jaw dia.
*Non-CE mark
9272
10 Hz to 20 kHz
20 or 200 A rated
2 V / 20 or 200 A output
φ46 mm(1.81 in) core jaw dia.
9555
Power supply for the 9277 /
9278 / 9279, and the 9270 /
9271 / 9272 / 9272-10 / 9709
Single sensor connectable
Clamp On Sensors
For power line current measurement
Output voltage (3196, 3197, 3169s, 8800s)
SPECIFICATIONS
9694
MODEL
CAT III 300V
9660
9661
CAT III 300V
9669
CAT III 600V
9667
CAT III 1000V
CAT III 600V
Primary current rating
Maximum input (45 to 66 Hz)
Output voltage
AC5 A
AC100 A
AC500 A
AC1000 A
50 A continuous
130 A continuous
550 A continuous
1000 A continuous
AC10 mV/A
AC1 mV/A
AC1 mV/A
AC0.5 mV/A
±0.3 %rdg.±0.01%f.s.
±1.0 %rdg.±0.01 %f.s.
Accuracy Amplitude (45 to 66 Hz) ±0.3 %rdg.±0.02%f.s. ±0.3 %rdg.±0.02%f.s.
Phase (45Hz to 5kHz)
within ±2˚
within ±1˚
within ±0.5˚
within ±1˚
within ±1.0% at 40 Hz to 5 kHz (9669: within ± 2.0%)
Frequency characteristic
300 V rms
600 V rms
Max. rated voltage to earth
Less than φ 15 mm
Less than φ 46 mm
Measurable conductor diameter
φ 55 mm, 80 ✕ 20 mm
Power supply
Dimensions and weight
● 9667 OPTION
—
—
AC500 A / 5000 A
10000 A continuous
AC500 mV f.s.
±2.0 %rdg.±1.5 mV(for input 10% or more of the range)
within ±1˚(minimum 10% input)
within ±3dB at 10Hz to 20 kHz
1000 V rms
Less than φ 254 mm
LR03 alkaline battery ✕ 4 (continuous operation
max. 168 hours) or AC adapter 9445 (option)
—
46W ✕ 135H ✕ 21D mm, 230 g
77W ✕ 151H ✕ 42D mm, 360 g 99.5W ✕ 188H ✕ 42D mm, 590 g
Sensor; 910 mm long, 240g,
Circuit; 57W ✕ 86H ✕ 30D mm, 140g
Cord length : 3 m, Output terminal : BNC terminal
f.s. is the sensorʼs rated primary current value.
AC ADAPTER 9445 (DC 9 V/1 A output)
For power line current measurement
Output voltage (2300, 3169s)
SPECIFICATIONS
MODEL
9695-02
9695-03
ZCT type leak current sensor
Output voltage
SPECIFICATIONS
MODEL
9661-01
9657
9658
9675
9657-10*
2331
CAT III 600V
CAT III 300V
Primary current rating
Maximum input (45 to 66 Hz)
Output voltage
CAT III 150V
CAT III 300V
AC1 A (9657-10; AC 10A)
AC10 A
Primary current rating
Maximum input (45 to 66 Hz) AC60 A continuous (-10: AC30A continuous) 30 A continuous 10 A continuous
AC25 mV/A (9657-10 : AC100 mV/A )
AC100 mV/A
Output voltage
Amplitude Accuracy
±1.0 %rdg.±12 μV ±3.5 %rdg.±12 μV ±1.0 %rdg.±0.5 mA
(45 to 66 Hz)
5 mA
1 mA
1 mA
Residual current
Effect of external magnetic fields Equivalent to 5mA, 7.5A max.(with a magenetic field of 400 A/m, AC)
300 V rms
150 V rms
300 V rms
Max. rated voltage to earth
Less than 12 mm × 30 mm Less than φ 30 mm
Measurable conductor diameter Less than φ 40 mm
—
Power supply
74W×145H×42D mm, 340 g 65W×52H×18D mm,
60W×112.5H×23.6D mm,
(-10 : 380 g)
100 g
160 g
Dimensions and weight
Cord length : 3 m, Output terminal : 2P plug (for 3638) Cord length : 3 m, BNC
AC50 A
AC100 A
AC500 A
60 A continuous 130 A continuous 550 A continuous
AC10 mV/A
AC1 mV/A
Accuracy Amplitude (45 to 66 Hz) ±0.3 %rdg.±0.02%f.s. ±0.3 %rdg.±0.02%f.s. ±0.3 %rdg.±0.01%f.s.
Phase (45Hz to 5kHz)
within ±2˚
within ±1˚
within ±0.5˚
within ±1.0% at 40 Hz to 5 kHz
Frequency characteristic
300 V rms
600 V rms
Max. rated voltage to earth
Less than φ 15 mm
Less than φ 46 mm
Measurable conductor diameter
—
Power supply
51W ✕ 58H ✕ 19D mm, 50 g
77W ✕ 151H ✕ 42D mm, 360 g
Dimensions and weight
Output terminal : M3 terminal
Cord length : 3 m
Option: Connection cable 9219
f.s. is the sensorʼs rated primary current value.
● 9695 OPTION
CONNECTION CABLE 9219 (for 3169, 3m)
Clamp Sensors
2331/3169
CAT III 300V
2331/3169
CAT III 300V
For power line current measurement
Output current (8205-10, 8206-10, 3636-20)
SPECIFICATIONS
MODEL
9650
9651
3636/
8205-10/8206-10
CAT III 600V
3636/
8205-10/8206-10
CAT III 300V
Primary current rating
Maximum input (45 to 66 Hz)
Secondary current rating
Amplitude Accuracy
(45 to 66 Hz)
AC100 A
130 A continuous
AC100 mA
AC500 A
600 A continuous
AC500 mA
±1.5 %rdg.±0.03 %f.s.
9668
8205-10/
8206-10
CAT III 600V
AC1000 A
1000 A continuous
AC1000 mA
±3.0 %rdg.±0.03 %f.s.
Frequency characteristic ±8% or better from 40 Hz to 1 kHz ±3% or better from 40 Hz to 1 kHz(deviation from accuracy)
300 V rms
600 V rms
Max. rated voltage to earth
Less than φ 15 mm
Less than φ 46 mm
Measurable conductor diameter
φ 55 mm, 80 ✕ 20 mm
—
Power supply
46W ✕ 135H ✕ 21D mm, 200 g 77W ✕ 151H ✕ 42D mm, 340 g 99.5W ✕ 188H ✕ 42D mm, 550 g
Dimensions and weight
Cord length : 3 m, Output terminal : 2P plug
f.s. is the sensorʼs rated primary current value.
34
Power Measuring Instruments
Power Measuring Instruments Index
For high level performance
3193
DC, or Single-phase to 3-phase
4-wire Wide-band up to 1 MHz
6 ch-Direct/ Clamp input
3194
Analysis station for Motor
Evaluation Power, Harmonics,
Rotation Speed, Torque,
Converter efficiency
. . . . . . . . . . . . . . . . . . . . . . p.40
3196
3197
9624-50
. . . . . . . . . . . . . . . . . . . . . . p.37
. . . . . . . . . . . . . . . . . . . . . . p.38
. . . . . . . . . . . . . . . . . . . . . . p.39
Power quality analyzer
DC, or Single-phase to 3-phase
4-wire
Clamp input
For use on production lines
3331
Power Measuring Instruments
Single-phase to 3-phase 3-wire
V,A,W,VA,var,integ., PF Phase
angle, Hz Direct input only
3333
. . . . . . . . . . . . . . . . . . . . . . p.40
. . . . . . . . . . . . . . . . . . . . . . p.40
Single-phase 2-wire V,A,W,VA,
var,integ., PF Phase angle, Hz
Direct input only
High Accuracy (±0.1%rdg. ±
0.1% f.s.)
Maximum Cost Performance
For managing power lines
3169 -20/-21
9625
3286 -20
. . . . . . . . . . . . . . . . . . . . . . p.36
. . . . . . . . . . . . . . . . . . . . . . p.36
. . . . . . . . . . . . . . . . . . . . . . p.46
Single-phase to 3-phase 4-wire
V,A,W,VA,var,integ., PF, Hz
Clamp input only
35
3332
POWER MEASUREMENT
SUPPORT SOFTWARE
for 3169-20/21
Clamp-On Power Meter
V,A,W,VA,var, PF,Hz, Hamonics
(V, A)
Fully portable Power Quality
Analyzer
1P2W to 3P4W
Clamp Input
PQA- HiVIEW PRO
Software application for 3196
and 3197
CLAMP ON POWER HiTESTER
3169-20 3169-21
Offering a new approach to energy-related
measurement such as energy conservation,
ISO14001 testing, equipment diagnosis, and
harmonics measurement.
CAT III 600V
STANDARD
●Measure up to two 3-phase, 3-wire systems
●Measure up to four single-phase, 2-wire systems
●5 A to 5000 A range, PC card data storage
●Power recording for individual waveforms
●Simultaneous recording of demand values and harmonics
●D/A output with 3169-21
9661×2, 9669×2 (option)
Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire,
and three-phase 4-wire systems (50/60 Hz)
Measurement item
Voltage, Current, Active power, Reactive power,
Apparent power, Power factor, Iintegrated value, Frequency,
Harmonics
Voltage: 150 V to 600 V, 3 ranges
Measurement range
Current (When using 9660): 5 A to 100 A, 4 ranges
Current (When using 9661): 5 A to 500 A, 5 ranges
Current (When using 9669): 100 A to 1 kA, 3 ranges
Current (When using 9667): 500 A / 5 kA, 2 ranges
Current (When using 9694): 0.5 A to 5 A, 3 ranges
Power: 75 W to 9 MW, 108 combination patterns
Basic accuracy
±0.2% rdg. ±0.1% f.s. + Clamp accuracy (for active power)
Clamp sensor accuracy 9660 (rated for 100 A): ±0.3% rdg. ±0.02% f.s.
9661 (rated for 500 A): ±0.3% rdg. ±0.01% f.s.
9669 (rated for 1000 A): ±1.0% rdg. ±0.01% f.s.
9667 (rated for 5000 A): ±2.0% rdg. ±1.5 mV
9694 (rated for 5 A): ±0.3% rdg. ±0.02% f.s.
Frequency characteristic Fundamental waveforms up to the 50th order ±3% f.s.
+ measurement accuracy
Other functions
PC card, RS-232C, D/A output (3169-21 only, 4 channels),
External I/O
Power supply voltage rating 100 to 240 V AC, 50/60 Hz
Dimensions, mass
210W×160H×60D mm ±5 mm, 1.2 kg ±100 g
(3169-20, 3169-21)
Accessories
Voltage cord set 9438-03 (1), Power cord (1),
Input cord label (1), Operating manuals (2), CD-R (1),
Connection cable 9441 (1) (for the 3169-21 only)
OPTIONS
● Current measurement
(The 3169-20/-21 cannot be used alone. Measurement requires one or more optional clampon sensors.)
CLAMP ON SENSOR rated current 100 A AC
9660
CLAMP ON SENSOR rated current 500 A AC
9661
CLAMP ON SENSOR rated current 1000 A AC
9669
FLEXIBLE CLAMP ON SENSOR rated current 5000 A AC
9667
CLAMP ON SENSOR rated current 5 A AC
9694
CLAMP ON ADAPTER rated current 1500 A AC, output 150 A (10:1 ratio) 9290-10
● Voltage measurement
VOLTAGE CORD (Supplied as standard with 3169-20/-21)
9438-03
● PC communication
POWER MEASUREMENT SUPPORT SOFTWARE
RS-232C CABLE for connection to PC
PC CARD 128M
PC CARD 256M
PC CARD 512M
9625
9612
9726
9727
9728
● Other options
CARRYING CASE 9720
CONNECTION CABLE for external I/O, 2 m length
CONNECTION CABLE (3169-21 standard), for D/A output, 2 m length
9440
9441
● Printer
PRINTER
AC ADAPTER for the 9442 PRINTER, EU type
AC ADAPTER for the 9442 PRINTER, USA type
RS-232C CABLE for connection to the 9442, 1.5 m length
RECORDING PAPER 112 mm width×25 m, roll type, 10 rolls per set
9442
9443-02
9443-03
9721
1196
Power Measuring Instruments
SPECIFICATIONS
Measurement lines
PRINTER 9442
Print method : Thermal serial dot printing
Paper width : 112 mm
Print speed : 52.5cps
Power supply : AC adapter 9443-02/03, or supplied nickel-metal hydride battery
(approx. 3000 lines of printing when fully charged and used
with the 9443-02/03)
Dimensions, mass : Approx.160W ✕ 66.5H ✕ 17D mm, approx.580g
POWER MEASUREMENT
SUPPORT SOFTWARE
9625
When purchasing the Printer 9442, make sure you also purchase the RS-232C cable
9721 and AC adapter 9443-02/03 so that you can connect it to the 3169-20/21.
36
POWER QUALITY ANALYZER
3196
Monitor and record the quality of power to
analyze the cause of trouble when it occurs !
CAT III 600V
Most complete instrument for power
quality troubleshooting
●Measure Dips, Swells, Interruptions,
Flicker, Transients
●Harmonic to the 50th order
●High frequency transient over voltage
●Detection and waveform display
●4 current and 4
voltage channels
●400Hz Fundamental wave
GPS Synchronization
STANDARD
STANDARD
9661×4 (option)
SPECIFICATIONS
Measurement lines
Voltage range
Power Measuring Instruments
Current range
Measurement
Method
Measurement
Function
Internal memory
Interface
Power supply
Dimensions, mass
Accessories
37
Single-phase two-wires, Single-phase three-wires,
Three-phase three-wires, Three-phase four-wires
ch1, ch2, ch3:150/300/600V
ch4: 60/150/300/600V(AC), 60/600V(DC)
9660: 50/100A, 9661:50/500A, 9667:500/5000A, 9669:1000A
Transient overvoltage: 2MHz/s
Arithmetic operation: 256points/cycle
Harmonic/Inter-harmonic:
2048points/10cycles (for 50Hz)
2048points/12cycles (for 60Hz)
1.Transient overvoltage
2.Voltage swell, Voltage dip, Voltage interruption
3.Frequency, Voltage, Current, Voltage/Current peak,
Active/Reactive /Apparent power, Power factor, DPF
4.Voltage unbalance ratio, Current unbalance ratio
5.Harmonic voltage/current/power,
Inter harmonic voltage/current,
Harmonic voltage current phase angle,
Total harmonic/inter harmonic distortion
6.IEC flicker[Pst, Plt], K factor
/ ∆V10(Japan)
7.EN-50160
13MB
PC card (Flash ATA card / up to 528 MB)
RS-232C, LAN (10BASE-T), HTTP server function
9458 AC adapter or 9459 battery pack
298W×215H×67D mm, 2.0 kg
Voltage cord (1set), 9458 AC adapter (1), Battery pack 9459 (1),
strap (1), Down 96 (data download software)
CLAMP ON SENSOR 9660
Curent up to 100A
CLAMP ON SENSOR 9694
Current up to 5A AC
FLEXIBLE CLAMP-ON SENSOR 9667
Current up to 5000A AC Diameter up to
254mm Rogovski-type current sensor
CLAMP ON SENSOR 9661
Current up to 500A
CLAMP ON SENSOR 9669
Current up to 1000A
OPTIONS
(The 3196 cannot be used alone. Measurement requires one or more optional sensors.)
● Current measurement
CLAMP ON SENSOR rated current 100A AC
9660
CLAMP ON SENSOR rated current 500A AC
9661
CLAMP ON SENSOR rated current 1000A AC
9669
FLEXIBLE CLAMP ON SENSOR rated current 5000A AC
9667
CLAMP ON SENSOR rated current 5A AC
9694
CLAMP ON ADAPTER rated current 1500A AC, output 150A (10:1 ratio) 9290-10
AC ADAPTER (for the 9667, for America, Japan)
9445-02
AC ADAPTER (for the 9667, for Europe)
9445-03
● Voltage measurement
VOLTAGE CORD (standard accessory)
WIRING ADAPTER (3P3W)
WIRING ADAPTER (3P4W)
9438-02
9264-01
9264-02
● PC communication
PQA HiVIEW PRO (PC application software for advanced data processing)
LAN CABLE (5m, with straight and crossover connectors)
PC CARD 128 M
PC CARD 256 M
PC CARD 512 M
9624-50
9642
9726
9727
9728
● Other options
AC ADAPTER (included)
BATTERY PACK (included)
CARRYING CASE (soft)
CARRYING CASE (hard)
9458
9459
9339
9340
● Printer
PRINTER (with one roll of recording paper)
AC ADAPTER (for 9670)
BATTERY PACK (for 9670)
BATTERY CHARGER (for 9672)
RECORDING PAPER (80 mm×25 m, 4 rolls, for 9670)
RS-232C CABLE (1.5 m, for printer connection)
9670
9671
9672
9673
9237
9638
PQA-HiVIEW
9624-50
Model 9624-50
PQA-HiVIEW PRO
software application
is a program for
analyzing binary
codes stored on a
PC card by Model
3196.
EN50160
POWER QUALITY ANALYZER
3197
The Most Comprehensive
Portable PQA on The Market
Catch Power Quality Problems on the Fly...
●Monitor for:
Inrush Current
Voltage Swells
Voltage Dips
Transient Overvoltage
Interruptions
●Measure and Record:
Power and Power Factor
Active/Reactive Energy
Demand
Load Changes (with graph display!)
Voltage and Current
Measurement Function
Interval Settings
Maximum Recordable Period
Internal Memory
PC Interface
Power supply
Dimensions and Mass
Accessories
1P2W/1P3W/3P3W2M/3P3W3M/3P4W/3P4W2.5E
Auto-detect (50Hz/60Hz)
600.0V
Manually Switchable from 2 Range Sets According to
Clamp Sensor 500.0mA/5.000A/50.00A/10.00A/100.0A/
500.0A/1.000kA/5.000kA
1.Transient overvoltage
2.Voltage swell, Voltage dip, Voltage interruption
3.Frequency, Voltage, Current, Voltage/Current peak,
Active/Reactive/Apparent power, Power factor, DPF
4.Voltage unbalance ratio
5.Harmonic voltage/current/power, Harmonic voltage
current phase angle, Total harmonic distortion
6.In rush currnt
AUTO/1/5/10/15/30/60 minutes
125 Days with internal non-volatile memory of 4MB stored data will not be deleted upon power OFF; partition
memory into 4 segments for maximum 31 days of recording
each
4MB
USB Ver.2.0 (for data transfer only)
9418-15 AC Adapter or 9459 Battery Pack
128W × 246H × 63D mm, 1.2 kg with battery pack
Voltage cords (4), BATTERY PACK (1), AC ADAPTER (1),
USB Cable (1), Basic PC Software (1), Carrying Case (1),
Strap (1)
Power Measuring Instruments
SPECIFICATIONS
Measureable Circuits
Measurement Line Frequency
Voltage Range
Current Range
STANDARD
(for data transfer only)
OPTIONS
CLAMP ON SENSOR 100A AC
CLAMP ON SENSOR 500A AC
FLEXIBLE CLAMP ON SENSOR 5000A AC
CLAMP ON SENSOR 1000A AC
CLAMP ON SENSOR 5A AC
CLAMP ON SENSOR 50A AC
CLAMP ON SENSOR 100A AC
CONNECTION CORD (for the 9695-02/9695-03)
CLAMP ON SENSOR 10A AC
CLAMP ON SENSOR 10A AC
VOLTAGE CORDS (bundled with standard 3197)
BATTERY PACK (bundled with standard 3197)
PQA HiVIEW PRO (PC application software)
9660
9661
9667
9669
9694
9695-02
9695-03
9219
9657-10
9675
9438-05
9459
9624-50
38
PQA-HiVIEW PRO
9624-50
Basic PC Analysis of Model 3196 and 3197 Data
● Viewer function
Use this function to display screens similar to those used for the
3196/3197.
Select from the TIME PLOT screen (voltage fluctuation, RMS
fluctuation, harmonic fluctuation, inter-harmonic fluctuation),
event list screen, event data screen (waveforms, vectors, DMM,
harmonics, event details), ∆V10 screen(Japanese standard), or
settings screen. In the TIME PLOT screen, and use the two cursors
(A and B) to calculate waveforms within a specified interval.
● Demand/integral power consumption function
Calculate demand and integral power consumption from TIME PLOT
data for effective power.
■ TIME PLOT screen
Measurement data is saved
in binary format
PC card
Data processing is quick
and easy using the 9624-50
PQA-HiVIEW software
Modem
LAN
Data stored on a PC card
can be transferred using
remote operations via a
LAN or modem
• Use it to create reports
• Use data converted to
CSV format
● Binary CSV format conversion function
Convert binary data into CSV format for event waveforms
within the specified range in the TIME PLOT screen or event
waveforms selected in the event waveform screen. Files saved
in CSV format can be used with spreadsheet software on your
PC.
● Print function
Use this function in each screen to output reports to a printer
connected to your PC.
This screen enables you to select four different types of data, including RMS
fluctuation, voltage fluctuation, harmonic fluctuation, and inter-harmonic
fluctuation data, and display the data in graphs corresponding to the TIME
PLOT screen of the 3196/3197.
■ Spot analysis using the cursor
Conduct spot analysis of time series data using
the A and B cursors.
■ Event list screen
This screen displays an event list
corresponding to the event list on the 3196.
Click an event!
Power Measuring Instruments
Calculations for the details within the
specified interval are displayed.
View power, voltage, and current data at
a single glance in the DMM screen!
■ Event data screen
1. Displays detailed data for the
event that you selected in the
event list.
2. Displays nine different screens that correspond to the
VIEW screen on the 3196, such as the waveform,
vector, harmonics, and DMM screens.
● ITIC curve display function
Make ITIC (CBEMA) curve analyses (limit curve) based on the
power quality control standards of the U.S.A.
●EN50160 display functions
(applicable standard is EN50160:1999)
Effectively evaluate and analyze the quality of power according to
EU standards.
● Downloading from LAN
Data (BINARY/TEXT/BMP) recorded on a PC card or the internal
memory of the 3196 can be downloaded via LAN to a personal
computer. (*This can be done without use of the freeware
Down96. Measurement on the 3196 must be halted during
download.)
39
● Report generation function
Choose from 3 types of report generation settings to take care
of all the troublesome reporting operations, and either send the
data to a printer or save as a Rich Text file. (Automatic: Output
basic items. Individual setting: Select any item for output. Detailed
setting: Specify a time-series graph in details for output.)
● Positive phase, negative phase, and zero phase function
Recalculate event data captured by 3P4W circuits, and display
each component of the voltage/current of the positive phase,
negative phase, and zero phase.
POWER HiTESTER
3332
Measure very low effective power, for stand-by
mode of home use equipment
●Ultra high-sensitive measurement, for use to measure
the effective power of equipment in stand-by mode:
Current 1.0000 mA full-scale, 0.1 µA resolution
●Wide measurement range, up to 50.000 A direct input
STANDARD
STANDARD
POWER HiTESTER
SPECIFICATIONS
Measurement lines
Measurement items
Single-phase/two-wire
Voltage, Current, Current peak, Active power, Apparent power,
Reactive power, Power factor, Phase angle, Frequency, Power
integration, Current integration
Voltage: 15.000V to 600.00V, auto or 6 ranges
Measurement ranges
Current: 1.0000mA to 50.000A, auto or 15 ranges
Power: 15.000mW to 30.000kW, auto or 90 ranges
Frequency: 4Hz to 100kHz, auto or 2 ranges
0 to±999999MAh/ MWh, (integration time up to 10000 hours)
Integration range
Wave peak measurement Current (displays maximum absolute value)
Basic accuracy
±0.1% rdg. ±0.1% f.s. (active power, at 45 to 66Hz)
Frequency characteristics 1Hz to 100kHz (1Hz to 100kHz at 10A or less, 10Hz to 10kHz
at 20A to 30A, 50/60Hz at 30A to 50A )
Signal output
Analog level: Voltage, current, active power, 5V DC f.s.
Waveform monitor: Voltage, current, 1V rms f.s.
Comparator function for 2 items
Other function
Scaling function (PT /CT/SC), Displays a moving average
function, GP-IB/RS-232C interface
Sampling rate
5 times /second
Power supply
100 to 240 V AC, 50/60 Hz
Dimensions, mass
210W×100H×261D mm, 2.5 kg
Power cord (1), Connector for EXT I/O (1)
Accessories
OPTIONS
GP-IB CONNECTOR CABLE (2 m)
GP-IB CONNECTOR CABLE (4 m)
PRINTER
AC ADAPTER (for the 9442, EU), 9443-03 (USA)
CONNECTION CABLE (for the 9442)
RECORDING PAPER
(25 m, 10 rolls /1 set, for the 9442)
9151-02
9151-04
9442
9443-02
9444
1196
3333 3333-01
SPECIFICATIONS
Measurement lines
Measurement items
Your Solution to
Meeting Energy Saving
Requirements
●Guaranteed for 3 years
●High Accuracy
(±0.1% rdg. ±0.1% f.s.)
●Maximum Cost Performance
3333-01
OPTIONS
PRINTER
CONNECTION CABLE (for 9442)
RECORDING PAPER
AC ADAPTER (for 9442, EU)
AC ADAPTER (USA)
STANDARD
POWER HiTESTER
3193
Wide spectrum power meter for comprehensive
device assessment
STANDARD
STANDARD
9442
9444
1196
9443-02
9443-03
RS-232C CABLE (9-pin to 9-pin, crossed cable/1.8m) 9637
RS-232C CABLE (9-pin to 25-pin, crossed cable/1.8m) 9638
GP-IB CONNECTOR CABLE (2m)
9151-02
GP-IB CONNECTOR CABLE (4m)
9151-04
Power Measuring Instruments
Single-phase/two-wire
Voltage, Current, Current peak, Active power, Apparent
power, Reactive power, Power factor, Phase angle,
Frequency, Power integration, Current integration
Voltage: 15.000 V to 600.00 V, 6 ranges
Measurement ranges
SPECIFICATIONS
Current: 1.0000 mA to 50.000 A, 15 ranges
Single-phase/two-wire
Measurement lines
Power: 15.000 mW to 30.000 kW, 90 ranges
power, Apparent
power,
Power
Frequency:
4 Hz to 100
kHz,
auto factor
or 2 ranges
Measurement items Voltage, Current, Active
to±999999
MAh/
MWh,50.00
(integration
Integration
range
Vmax),
Current:
mA to time up to 10000 ho
Measurement ranges Voltage: 200.0 V 0(300.0
20.000
A (30.00 Amax),
ranges maximum absolute value)
Current6(displays
Wave peak
measurement
Power: 10.000 W±0.1
to 4.000
kW,
6 ranges
Basic accuracy
% rdg.
±0.1
% f.s. active power, at 45 to 66 Hz)
±0.1
% rdg. ±0.1 10
% f.s.
power,
Hz)at 100 mA or less, 10 H
Basic accuracy Frequency
characteristics
Hz (active
to 100 kHz
(10 at
Hz45toto1066kHz
Frequency characteristics 45 Hz to 5 kHz 10 kHz at 20A to 30A, 50/60 Hz at 30 A to 50 A )
Analog
level: aVoltage,
current,
active power, 5 V DC f.s.
Scaling function (PT/CT),
Displays
simple average
function,
Other functionsSignal output
Waveform
monitor:
Voltage,
current,
1 V rms f.s.
RS-232C interface (Model
3333-01
also includes
GP-IB
interface)
5 times/second Comparator function for 2 items
Sampling rate Other function
Scaling function (PT /CT/SC), Displays a moving average
100 to 240 V AC,function,
50/60 Hz,
20 VA max interface
Power supply
GP-IB/RS-232C
mm,
1.9 kg
160W
Dimensions, mass
Sampling
rate × 100H × 227D
5 times
/second
Power cord (1) 100 to 240 V AC, 50/60 Hz
Accessories
Power supply
210W × 100H × 261D mm, 2.5 kg
Dimensions, mass
Power cord(1), Connector for EXT I/O(1)
Accessories
SPECIFICATIONS
Measurement lines
Single-phase/two-wires to three-phase/four-wires
(Through the use of various input units)
Measurement items
(When using 9600, 9601, 9602, optional) Voltage, current, voltage
/current peak, effective/reactive/apparent power, power factor, phase,
frequency, current/power integration, load rate, efficiency (When
using 9603, optional) Voltage, torque, RPM, frequency, motor output
(When using 9605, optional) Harmonic, waveform, voltage fluctuation
/ flicker measurement function
Measurement ranges
Voltage: 6.0000V to 1.0000kV (depends on use of the input unit)
Current: 200.00mA to 500.00A (depends on use of the input unit)
Power: Depends on combination of voltage and current ranges
Integration range
0 to ±999999 TAh/ TWh, (integration time up to 10000 hours)
Basic accuracy
±0.1% rdg. ±0.1% f.s. (voltage, current, power, at 45 to 66Hz)
used with 9600 to 9602 Input unit Note: When used together with the 9270 to 9272, and 9277 to 9279, resulting
accuracy is the sum of that indicated above and the accuracy of these clamp sensors.
Frequency characteristics using with 9600: DC, 0.5Hz to 1MHz using with 9601: 5Hz to 100kHz
using with 9602: DC, 0.5 Hz to 200 kHz (depends on the clamp accuracy)
Signal output
Analog level: Voltage, current, active power, 5V DC f.s.
Waveform monitor: Voltage, current, 1V rms f.s.
D/A output: Outputs 8 arbitrarily selected items, DC±5V f.s.
Other functions
6.4 inch TFT color LCD, RMS/MEAN rectification, FDD,
GP-IB/RS-232C interface, scaling, averaging
Power supply
100/120/200/230 V AC (switched automatically), 50/60 Hz
Dimensions, mass
430W×150H×370D mm, 15 kg (with all options)
Accessories
Power cord (1), Connector for EXT I/O (1)
OPTIONS
(The 3193 cannot be used alone. Measurement requires one or more input units.)
*Note: 9600 to 9605 : factory installation only
*Certain Clamp-on sensors are not CE-mark
compliant. Please refer to p.34
AC/DC DIRECT INPUT UNIT
9600
AC DIRECT INPUT UNIT
9601
AC/DC CLAMP INPUT UNIT
*9602
EXTERNAL SIGNAL INPUT UNIT 9603
PRINTER UNIT
9604
HARMONIC / FLICKER MEASUREMENTS UNIT 9605
CLAMP ON SENSOR
*9270 series
CLAMP ON ADAPTER
9290-10
40
Clamp Testers
Clamp Testers Index
Current Meters
3127-10
AC current, up to 300A,
φ33 mm dia.
3128-10
(for AC only, basic type)
3280-10
3280-20
3281
AC current, up to 1000A, AC current, up to 1000A, AC current, up to 600A,
φ33 mm dia., light 100g φ33 mm dia., light 100g φ33mm dia., Multi-function
. . . . . . . . . . . . . . . p.44
and slim 16 mm
and slim 16 mm
True RMS
3282
AC current, up to 1500A,
φ55 mm dia.
. . . . . . . . . . . . . . . p.45 . . . . . . . . . . . . . . . p.43
Current Meters
3284
3287
3285/3285-20
3288
DC and AC current, up
to 200 A, φ33 mm dia.,
Multi-function
. . . . . . . . . . . . . . . p.44
Clamp Testers
DC and AC current, up
to 2000 A, φ55 mm dia.,
Multi-function
. . . . . . . . . . . . . . . p.44
AC current up to 1500 A,
secondary current 1/10 of
primary, φ55 mm dia. or
88 mm width
Superior phase angle
characteristics
3290/3290-10
AC/DC current, up to 100 DC and AC current, up to
A, φ35 mm dia., True
2000A
RMS rectifier
Choice of three sensors
. . . . . . . . . . . . . . . p.43
AC/DC current, up to
1000 A, φ35 mm dia.,
Average rectifier
. . . . . . . . . . . . . . . p.43
CT-101A
3286-20
3283
3293
60.00A / 600.0A / 1000A Clamp-On Power Meter
V,A,W,VA,var, PF,Hz,
φ30mm dia. light 90 g
LCD Display reversible Harmonics (V, A only)
. . . . . . . . . . . . . p.45 φ55mm dia. or 80mm
busbar
AC current, up to 1000A,
. . . . . . . . . . . . . . . p.46
φ46mm dia., Multi-function
. . . . . . . . . . . . . . . p.44
(for AC/DC, two-way type)
9691/9692/9693
9691 100A φ35mm
9692 200A φ33mm
9693 200A φ55mm
. . . . . . . . . . . . . . . p.45
Conversion Adapter
9290-10
41
. . . . . . . . . . . . . . . p.43
3291
AC current up to 15 A,
secondary current 1/1 or
10 times of primary,
φ25 mm dia.
Leak current, high-sensitivity
10mA range 10µA resolution
Load current up to 200A,
φ40mm dia.
. . . . . . . . . . . . . . . p.44
(for AC only, clamp-on type)
30.00mA / 300.0mA / 6.000A
60.00A / 600.0A / 1000A
φ24mm dia. light 120 g
LCD Display reversible
. . . . . . . . . . . . . p.45
CLAMP ON HiTESTERs
Table of functions
AC Current ranges Other current ranges AC Voltage ranges Other voltage ranges
3280-10
3280-20
True RMS
3281
42.00 to 1000A AC,
3 ranges
3280-10: Average
rectifier effective value
3280-20: Effective
value rectifier
4.200 to 600V AC,
4 ranges
3280-10 : Average
rectifier effective value
3280-20 : Effective
value rectifier
None
Wave peak value at AC
Current
300.0 or 600V AC,
3281: 75.0 to 1000A
2 ranges
peak, 3 ranges
Effective value rectifier
3282: 75.0 to 1700A
peak, 3 ranges
3282
3281: 30.00 to 600A
AC, 3 ranges
3282: 30.00 to 1000A
AC, 3 ranges
Effective value rectifier
3283
10.00mA to 200 A AC,
5 ranges
Effective value rectifier
None
None
3284
AC, AC+DC(RMS or
Peak value)
3284: 20.00 or 200.0A
AC, 2 ranges
3285: 200.0 or 2000A
AC, 2 ranges
Effective value rectifier
DC (Average or Peak
value)
3284: 20.00 or 200.0A
DC, 2 ranges
3285: 200.0 or 2000A
DC, 2 ranges
AC, AC+DC
(RMS or Peak value)
30.00 to 600V AC,
3ranges
Effective value rectifier
True RMS
True RMS
True RMS
True RMS
3285
True RMS
3286-20
True RMS
3287
True RMS
3288
3290
True RMS
3290-10
True RMS
3127-10
3128-10
20.00 to 1000 A AC,
3 ranges
Effective value rectifier
3287: 10.00 or 100.0A
AC, 2 ranges
Effective value rectifier
3288: 100.0 or 1000A
AC, 2 ranges
Average rectifier
effective value
3127: 6 to 300A AC,
5 ranges
3128:15 to 1500A AC,
5 ranges
Average rectifier
effective value
Display
True RMS
3281
True RMS
3282
True RMS
3284
True RMS
3285
DC mode
3287: 10.00 or 100.0 A
DC, 2 ranges
3288: 100.0 or 1000 A
DC, 2 ranges
3287: 4.200 to 600V
AC, 4 ranges
Effective value rectifier
3288: 4.200 to 600V
AC, 4 ranges
Average rectifier
effective value
Sampling rate
True RMS
3287
True RMS
3288
3290
True RMS
3290-10
True RMS
3127-10
3128-10
DC (Average or
Peak value)
30.00 to 600V
DC, 3 ranges
DC mode
420.0 mV to 600 V
DC, 5 ranges
None
DC, or AC 1V / f.s.
(200A range:2V / f.s.)
Level output with
REC mode
Waveform output with
MON mode
10m to 10A range:
±1.0 % rdg. ±5 dgt.
200A range:
±1.5 % rdg. ±5 dgt.
Frequency:
±0.3 % rdg. ±1 dgt.
Frequency:1 to 1000Hz
Mode: Max./Min./AVE.
/RMS
Record mode/Auto-off
DC, or AC 1V / f.s.
Level output with REC
mode
Waveform output with
MON mode
AC current:
±1.3% rdg. ±3 dgt.
AC voltage:
±1.0% rdg. ±3 dgt.
Frequency:
±0.3% rdg. ±1 dgt.
DC Voltage range:
75 V DC, 1 range
9442 PRINTER
(Option)
Resistance: 420.0 to
42.00MΩ, 6 ranges
Accuracy: ±2.0% rdg.
±4 dgt. (at 420 to 420kΩ
range) Continuity: 420.0Ω
(Buzzer sounds at approx.
50Ω or less)
None
DC,or AC Current : 2V/f.s.
Level output with
REC mode
Waveform output with
MON mode
Integ./Frequency : 1V/f.s.
Frequency :
10 to1000 Hz
None
150 to 750V AC,
3 ranges
Average rectifier
effective value
Frequency:
30.0 to 1000 Hz
Filter function:
180Hz±30Hz/-3dB
Power(Single-phase or
3 phase): 3kW to
600kW(Single-phase)
6kW to 1200kW(3-phase)
Power factor, Phase angle:
Frequency: 30.0 to 1000Hz
Voltage/current harmonic
levels
None
None
AC current:
±1% rdg. ±5 dgt.
AC voltage:
±1% rdg. ±3 dgt.
Peak: ±3% rdg. ±5 dgt.
Frequency:
±0.3% rdg. ±1 dgt.
Resistance:1k or 100kΩ
range
Temperature*: -50 to
200°C
*9021-01 TEMPERATURE
PROBE required,
(sold separately)
Crest factor
(RMS)
Effect of external
magnetic fields
Max. circuit
voltage
Core jaw dia.
None (3280-10)
2.5 (3280-20)
No provision
600V AC rms
φ33 mm
None
AC voltage: 50 to 500Hz
AC current: 50 or 60Hz
(3280-10)
AC current: 40 to 1kHz
(3280-20)
40 to 1000 Hz
40 to 2kHz
3284: DC, 10 to 2kHz
3285: DC, 10 to 1kHz
AC current:
±1.3 % rdg. ±3 dgt.
AC voltage:
±1.0 % rdg. ±3 dgt.
AC current: 45 to 1kHz
Power:
AC voltage: 30 to 1kHz
±2.3% rdg. ±5 dgt.(1φ)
±3.0% rdg. ±10 dgt.(3φ)
(Accuracy guaranteed only
for 50/60Hz cosφ=1)
AC current:
±1.5 % rdg. ±5 dgt.
AC voltage:
±2.3 % rdg. ±8 dgt.
DC voltage:
±1.3 % rdg. ±4 dgt.
DC current:
±1.5 % rdg. ±5 dgt.
Continuity:
±2.0 % rdg. ±6 dgt.
AC current: 3287
DC, 10 to 1kHz
AC current: 3288
DC, 10 to 500Hz
AC voltage:
30 to 500Hz
AC/DC/AC+DC
Current :±1.3 % rdg.
+ 3 dgt. (Typical)
Frequency : ±0.3 % rdg.
+ 1 dgt. (Typical)
DC to 500Hz (9691)
DC to 1kHz(9692, 9693)
±2.3 % rdg. + 8 dgt.
AC current: ±3% f.s.
AC/DC voltage:±3% f.s.
50 or 60 Hz
Power supply
Dimensions/mass
Included
accessories
TEST LEAD 9208 (1)
CARRYING CASE
9398 (1)
2.5 times /sec or
1 time /3 sec
Digital /3000 dgt.
Bar graph /35 seg.
3281: 1.5A equivalent
max. at 400 A/m
2 or 4 times /sec
2.5 (1.7 at 600A,
(Slow: 1 time /3 sec) 1000A, 600 V range) 3282: 0.2A equivalent
max. at 400 A/m
600V AC rms
(insulated wire)
3281: φ33 mm
3282: φ46 mm
6F22(006P) ×1
3281: 62W×218H×
39D mm /350 g
3282: 62W×230H×
39D mm /400 g
TEST LEAD 9207-10(1)
CARRYING CASE
9399 (1)
Hand strap(1)
Digital /2000 dgt.
Bar graph /35 seg.
corresponds to 5mA,
2 or 4 times /sec
2.5
max. 7.5 mA
(Slow: 1 time /3 sec) (1.5 at 200A range) equivalent max.
at 400A/m
300 V AC rms
(insulated wire)
φ40 mm
6F22(006P) ×1
or AC adapter
62W×225H×39D
mm/400 g
CARRYING CASE
9399 (1)
Hand strap(1)
Current / 2500 dgt.
Voltage / 3750 dgt.
Bar graph /35 seg.
2 or 4 times /sec
(Slow: 1 time /3 sec)
2.5
1.5
(3284: 200A range),
1.42
(3285: 2000A range)
3284: 0.5A equivalent
max. at 400 A/m
3285: 2.0A equivalent
max. at 400 A/m
600V AC rms
(insulated wire)
3284: φ33 mm
3285: φ55 mm
6F22(006P) ×1
or AC adapter
3284: 62W×230H×
39D mm /460 g
3285: 62W×260H×
39D mm /540 g
TEST LEAD 9207-10(1)
CARRYING CASE
(1 for 3284) 9399
CARRYING CASE
(1 for 3285) 9345
Hand strap(1)
Digital /LCD,
maximum 6000 dgt.
Normal: 1 time /sec
(Slow: 1 time /3 sec)
2.5 (1.7 at 1000 A,
600 V range)
1.00 A equivalent
max. at 400 A/m
600 V AC rms
(insulated wire)
φ55 mm or
80mm busbar
6LR61/6LF22
(006P)×1
100W×287H×39D
mm /650 g
VOLTAGE CORD
9635 (1)
CARRYING CASE
9245 (1)
Hand strap(1)
Digital /LCD,
maximum 4199 dgt.
2.5 times /sec
3287
2.5 or less (150A,
1000V maximum)
3288 None
No provision
600 V AC rms
(insulated wire)
3287: φ35 mm
3288: φ35 mm
3287: 57W×180H×
CR2032 (3VDC) ×1 16D mm /170 g
3288: 57W×180H×
16D mm /150 g
2.5 or less
9691 : 0.5 A equivalent
max. at 400 A/m
9692 : 0.7 A equivalent
max. at 400 A/m
9693 : 2.0 A equivalent
max. at 400 A/m
600 V AC rms
(insulated wire)
9691 : φ35mm
9692 : φ33mm
9693 : φ55mm
Type 3 alkaline dry
cell (LR6) ×4
or AC adapter
600V AC rms
(insulated wire)
3127: φ33 mm
3128: φ55 mm,
or 80 mm busbar
R6P(AA)×1
True RMS
3286-20
Distortion check:
1 to 5 Crest factor
Resistance:1k or 10kΩ range
Temperature*: -50 to 150°C
Frequency: 30.0 to 1000 Hz
Mode: Slow/Peak/C.F./RMS
Record mode/Auto-off/
Conduction
None
AC current:
±1.5 % rdg. ±5 dgt.
AC voltage:
±2.3 % rdg. ±8 dgt.
DC voltage:
±1.3 % rdg. ±4 dgt.
Continuity:
±2.0 % rdg. ±6 dgt.
Frequency
characteristics
AC current / voltage
Digital /LCD,
maximum
4199 dgt.
True RMS
3283
150.0/300.0/600 V AC,
3 ranges
Effective value rectifier
None
Wave peak value at
AC Voltage
up to 750 or 1000V
peak, 2 ranges
Accuracy
(at 50 or 60Hz)
Digital / LCD
maximum 3000 dgt.
Bar graph / 20 seg.
3290-10
maximum 9999 dgt.
Indicator type
Fast : 4 times / sec,
(3290-10
FAST : 10 times/sec )
Normal : 2 times / sec,
Slow : 1 time / 3sec
None
None
No provision
CR2032 (3 VDC) ×1 57W×175H×
16D mm /100 g
3290 : 155W×98H×
47D mm / 545g
9691 : 53W×129H×
18D mm / 230g
9692 : 62W×167H×
35D mm / 410g
9693 : 62W×196H×
35D mm / 500g
3127-10: 78W×190H×
34D mm /340 g
3128-10: 99W×237H×
34D mm /570 g
Clamp Testers
3280-10
3280-20
None
3290+9691 : AC 20 to 100A
3290+9691 : DC 20 to 100A
3290+9692 : AC 20 to 200A
3290+9693 : AC 200 to 2000A 3290+9692 : DC 20 to 200A
AC+DC, AC RMS, AC MEAN 3290+9693 : DC 200 to 2000A
DC Voltage range:
420.0mV to 600V DC,
5 ranges
Resistance: 420.0 to
42.00 MΩ, 6 ranges
Accuracy: ±2.0 % rdg.
±4 dgt. (at 420 to
420 kΩ range)
Continuity: 420.0Ω
(Buzzer sounds at
approx. 50Ω or less)
None
Analog output
Printer output
Other functions
TEST LEAD 9208(1)
CARRYING CASE
9398 (1)
strap
TEST LEAD 9067 (1)
CARRYING CASE
(for 3127) 9351(1)
CARRYING CASE
(for 3128) 9148 (1)
42
CLAMP ON HiTESTER
3280-10
Easy operation !
●1000 A clamp aperture: 33 mm dia.
●Light 100 g, and Slim 16 mm
●Independent-opening double-lever design
●Slim body allows easy clamping even for narrow conductors
●No metal (iron core) exposure, ensuring enhanced safety
9209 (option)
CAT III 600 V
(Current range)
CAT II 600 V
(Voltage range)
OPTIONS
TEST LEADS HOLDER 9209
*CT-101A LINE SPLITTER
*Note: Non-CE mark product
CLAMP ON HiTESTER
3280-20
CAT III 600 V
(Current range)
CAT II 600 V
(Voltage range)
True RMS !
●1000 A rms, clamp aperture: 33 mm dia.
●Light 100 g, and Slim 16 mm
●Independent-opening double-lever design
●Slim body allows easy clamping even for narrow conductors
●No metal (iron core) exposure, ensuring enhanced safety
OPTIONS
TEST LEADS HOLDER 9209
*CT-101A LINE SPLITTER
*Note: Non-CE mark product
CLAMP ON AC/DC HiTESTER
Clamp Testers
3288
Compact & easy, one-touch maintenance on
all types of AC/DC equipment
3287
●The 3287 can handle even cogenerator
/ inverter energy-saving equipment
(10/100A)
●Use the 3288 for high current
measurements such as UPS emergency
batteries and train motors (100/1000A)
●A slim core of only 10 mm (0.39") for
easy clamping even in crowded wiring
3287 3288
9209 (option)
OPTIONS
TEST LEADS HOLDER 9209
*CT-101A LINE SPLITTER
*Note: Non-CE mark product
CAT III 600 V
(AC/DC A)
CAT II 600 V
(AC/DC V)
43
3287
DIGITAL CLAMP ON HiTESTER
3281 3282
True RMS is shown in the distorted waveform
3282
3281: 600 A AC, φ 33 mm 3282: 1000 A AC, φ46 mm
●AC Current/Voltage, Frequencies, Resistance, Conduction check,
Temperature (probe sold separately)
●Wave peak value, Waveform distortion check
●Auto-power off to prevent the power from being left on
●Non-fuse type protects up to 600 V AC
3281
CAT IV 600 V
OPTIONS
THERMISTER TEMPERATURE PROBE *9462
*CT-101A LINE SPLITTER
*Note: Non-CE mark product
CLAMP ON LEAK HiTESTER
3283
Easily monitor leak current fluctuations
OPTIONS
●High-sensitivity with a full scale of 10mA (resolution:10µA)
●High-accuracy at ±1%
●True RMS measurement
●Analyzer functions, for filtering and output signals
●Wide bandwidth, 5Hz to 15kHz (Monitor output)
AC ADAPTER (for USA) 9445-02
AC ADAPTER (for EU)
9445-03
CLAMP ON ADAPTER
9290-10
*CT-101A LINE SPLITTER
(cannot be used for leakage current, for use on load current only)
OUTPUT CORD
*9094
*Note: Non-CE mark product
CAT III 300 V
Clamp Testers
CLAMP ON AC/DC HiTESTER
3284 3285 3285-20
3285
Analysis for DC to distorted waves
●3284: 200 Arms, clamp aperture: 33 mm dia.
●3285: 2000 Arms, clamp aperture: 55 mm dia.
●3285-20: With resistance measurement range
No analog output
Cannot be used with AC adapter
●Inrush current crest value
●RMS value of full-wave rectified waveforms
●Waveform and harmonic analysis
3284
OPTIONS
CAT III 600 V
3285-20
AC ADAPTER (for USA) 9445-02
AC ADAPTER (for EU) 9445-03
CLAMP ON ADAPTER 9290-10
*CT-101A LINE SPLITTER (cannot be used for DC,
AC+DC current, for use on AC current only)
OUTPUT CORD *9094
*Note: Non-CE mark product
44
CLAMP ON HiTESTER
3291 3293
DIGITAL CLAMP ON HiTESTER
3291
Flip Clamp !
CLAMP ON LEAK HiTESTER 3293
Flip Clamp !
CAT III 600 V,
CAT IV 300V
SPECIFICATIONS
30.00 mA / 300.0 mA / 6.000A / 60.00 A / 600.0A / 1000 A AC (Auto range)
Filter on : ±1.5 % rdg. ±5 dgt. at 50 or 60Hz)
AC Current range
Filter off : ±2.0 % rdg. ±5 dgt. at 45 to 60Hz)
Filter off : ±3.0 % rdg. ±5 dgt. at 40 to 45Hz, 66 to 600Hz)
Filter on/off (180Hz, -3dB), Display hold, Max. value
Other functions
hold, Auto power off, LCD Display reversible
Frequency characteristics 40 to 600 Hz
2 times/sec (Bar graph: 4 times/ sec)
Sampling rate
Crest factor (RMS) 2.0 (600 A and under) 1.5 and under (600A over)
Core jaw dia.
φ24 mm
CR2032× 1
Power supply
Dimensions, mass 50 mm W × 130 mm H × 26 mm D, 120 g
CARRYING CASE 9757 (1), strap (1)
Accessories
SPECIFICATIONS
60.00 A / 600.0A / 1000 A AC (3 ranges)
Filter on : ±1.5 % rdg. ±5 dgt. at 50 or 60Hz)
AC Current range Filter off : ±2.0 % rdg. ±5 dgt. at 45 to 60Hz)
Filter off : ±3.0 % rdg. ±5 dgt. at 40 to 45Hz, 66 to
600Hz)
Filter on/off (180Hz, -3dB), Display hold, Max.
value hold, Auto power off,
Other functions
LCD Display reversible
Frequency characteristics 40 to 600 Hz
2 times/sec (Bar graph: 4 times/ sec)
Sampling rate
Crest factor (RMS) 2.0 (600 A and under) 1.5 and under (600A over)
Core jaw dia.
φ30 mm
CR2032× 1
Power supply
Dimensions, mass 50 mm W × 136 mm H × 26 mm D, 90 g
CARRYING CASE 9757 (1), strap (1)
Accessories
3293
Flip clamp
Display reversible
3291
CLAMP ON AC/DC HiTESTER
CLAMP ON AC/DC SENSOR
CAT III 300 V
3290/3290-10
9691 9692 9693
All the Functions You Need for
Measurement at DC or 1Hz and Up
Clamp Testers
●Choice of three sensors (Example combinations)
3290+9691 : Measure up to 100A (φ35mm)
3290+9692 : Measure up to 200A (φ33mm)
3290+9693 : Measure up to 2000A (φ55mm)
●Choice of measurement methods
DC (for battery measurement)
AC+DC RMS (for full-/half-wave rectification measurement)
AC RMS (for current distortion measurement)
PEAK (for peak value measurement) of inrush current, etc.)
●Choice of output (Simultaneous output)
Effective value output, frequency output,
waveform output
●Choice of response times (Switchable
among three response times)
●LPF function (filters out unnecessary
harmonics : fc=550Hz)
●3290-10 Functions
Current integral measurement
(obtain polarity-specific integrated DC values)
Operating time/duty measurement
CLAMP ON HiTESTER
3290-10
9692
3290
CAT III 600 V
9691
3127-10 3128-10
One meter drop-proof "Tested Tough!"
●With the range of 300 A (3127-10), 1500 A (3128-10)
●Temperature measurement
●Ohmmeter circuit tested to 250 V AC over voltage-OK
●Clamp-on measurement for busbars and thick conductors (3128-10)
OPTIONS
THERMISTER TEMPERATURE PROBE
*9021-01
CLAMP ON ADAPTER ( for large AC current ) 9290-10
*CT-101A LINE SPLITTER
*Note: Non-CE mark product
45
CLAMP ON POWER HiTESTER
3286-20
All powerful ! Easy operation !
True-RMS Clamp-on Power Meter !
●Use as a single-phase power meter or power factor
meter (3kW to 600kW range)
●Simple checking of three-phase lines (6kW to
1200kW range)
●Check power supply fluctuations
●1000 A, 1000 Hz, peak and harmonic measurement
●True RMS (effective value) display method
●Optional printer (9442 PRINTER)
CAT III 600 V
RS-232C PACKAGE 9636-01
SPECIFICATIONS
Power factor/ Phase angle/ Reactivity measurement
Phase discrimination by phase detection (zero crossing)
0.000 (lead) to 1.000 to 0.000 (lag)
90.0°(lead) to 0.0°to 90.0°(lag)
0.000 (lead) to 1.000 to 0.000 (lag)
Measurement items
Measurable conductor diameter
Display
Rectification method
Display update rate
φ
Analog response time
Voltage/ Current/ Power measurement
Range Table
150.0 V
AC
Voltage
300.0 V
600 V
Single-phase
*3-phase(balanced load)
Single-phase
*3-phase(balanced load)
Single-phase
*3-phase(balanced load)
AC Current
20.00 A
200.0 A
1000 A
3.000 kW
30.00 kW
150.0 kW
6.000 kW
60.00 kW
300.0 kW
6.000 kW
60.00 kW
300.0 kW
6.000/12.00 kW 60.00/120.0 kW
600.0 kW
12.00 kW
120.0 kW
600.0 kW
24.00 kW
240.0 kW
600.0/1200 kW
*3-phase power is calculated and displayed on the basis of a balanced, 50/60 Hz, sine wave input.
For apparent power and reactive power, the unit of watts in the above table is replaced by VA and var respectively.
0.000 (lead) to 1.000 to 0.000 (lag); 1φ only
1000 Arms cont.
600 Vrms (insulated conductor)
Voltage: 10 V to 600 V, Current: 10 A to 1000A,
Power: 80 V to 600 V and 10 A to 1000 A
Voltage: 0.6 Vrms, Current: 0.6 Arms
Min. Display value
Display indication range 5 or less are zero-suppressed, and the upper limit is to 125% of
the range setting (to 100% for the 1000 A range)
(RMS value)
2.5 or less (1000 A and 600 V range is 1.7 or less)
Circuit dynamic
Effective value P.F.
Max. allowable current
Max. usable circuit voltage
Effective input range
Wave peak measurement
Effective in the voltage and current functions
Measurement range
150 (375 peak) / 300 (750 peak) / 600 (1020 peak) V
20 (50 peak) / 200 (500 peak) / 1000 (1700 peak) A
Effective Input Range
Effective value of sine wave is within effective input permisible
in the range and within circuit dynamic
Clamp Testers
Frequency measurement
Effective in the voltage and current functions
Measurement range
30.0 Hz to 100 Hz (at 100.0Hz range)
100 Hz to 1000Hz (at 1000Hz range)
Min. input level
Voltage 10 Vrms-sine wave, Current 1 Arms-sine wave
Harmonic measurement
Effective in the voltage and current functions
Measurement items
Level of each order, percentage of each order and total harmonic
distortion (THD-F and THD-R)
Measurement range
Fundamental frequency 45 Hz to 65 Hz
Window width
1 cycle (45 Hz to 65 Hz), Data points: 256 points
Window type
Rectangular
Orders analyzed
Up to 20th
Other functions
Phase detection
Record
Battery capacity
Data hold
Auto power off
Data output
Normal/ reverse/ missing (at 3-phase balanced load)
MAX. value and MIN. value (Effective in the voltage, current and
effective / apparent power functions)
Displayed in % when the unit is powered on
Holds display
Approx. 10 minutes, buzzer sounds just before power is turned off,
can be extended or cancelled
RS-232C interface by optical insulating coupler
OPTIONS
RS-232C PACKAGE
PRINTER
RS-232C CABLE (for 9442 printer)
9636-01
9442
9636
AC ADAPTER (for 9442 printer, EU)
9443-02
AC ADAPTER (for 9442 printer, America) 9443-03
RECORDING PAPER (for 9442 ,10 rolls)
1196
VOLTAGE CORD
9635
46
Field Measuring Instruments
Field Measuring Instruments Index
Analog Multi Meters
3030-10
Basic type analog
tester,
Average rectifier
3008
Use for industrial power
lines
Average rectifier
. . . . . . . . . . . . . p.54
LAN Cable Tester
3665-20
Optical Power Meter Noise Search Tester
3661-20,3662/63-20
Affordable LAN cable Optical loss
testing, Wire-Map, Cable measurement tool
length, Direction-Check LASER LIGHT
SOURCE 3662/63-20
. . . . . . . . . . . . . . p.55 . . . . . . . . . . . . . . . p.55
3664
3244
. . . . . . . . . . . . . . p.49
. . . . . . . . . . . . . . p.49
Pencil type DMM,
Average rectifier
Card size DMM with
emphasis on safety,
Average rectifier
3245
3255-50
3256-50, -51
. . . . . . . . . . . . . . p.50
. . . . . . . . . . . . . . p.50
A card size DMM with Built tough for use with
solar charged battery,
industrial power lines
Average rectifier
DMM, Average rectifier
3470
Magnetic field tester
for home appliances
Noise Search Tester
Frequency range 500 Hz to 30 MHz
0 dBV and -20 dBV f.s., 2 ranges
OPTICAL POWER METER
For testing DVD recorders,
CD drives, Copiers, laser
. . . . . . . . . . . . . . p.56
printers, etc.
. . . . . . . . . . . . p.56
Digital Multi Meters (basic functions)
3246
3144-20
Terminal shutter interlock
mechanism DMM,
Average rectifier
. . . . . . . . . . . . . p.56
Phase Detector
3126-01
3129/3129-10
Phase detector, Rotary Phase Detector,
disk style, 110 to 480V Non-contact types,
AC 70 to 600 V(50/60 Hz)
AC 70 to 1000V (3129-10)
. . . . . . . . . . . . . . . p.53
Digital Multi Meters (multi-functional and high precision)
3257-50, -51
Field Measuring Instruments
Terminal shutter interlock
mechanism DMM,
True RMS rectifier
. . . . . . . . . . . . p.50
Multi-function type, 51000
count display,
RS-232C/USB communication,
True RMS rectifier
. . . . . . . . . . . . . . . p.44
3802-50
Low-cost type, 51000 count
display,
RS-232C/USB communication,
True RMS rectifier
3803
Low-cost type, 4000 count
display,
RS-232C communication,
Average rectifier
. . . . . . . . . . . . . p.44
3804, 3805
Testing voltage 250V
to 1000V, Two ranges,
Indicator type
3451-11 to -15
Testing voltage 125V
to 1000V, Single
range, Compact and
lightweight, Luminous
scale indicator type
. . . . . . . . . . . . . . p.52
3452-11 to -13
Testing voltage 25V
to 1000V, Three
ranges, Compact and
lightweight, Luminous
scale indicator type
. . . . . . . . . . . . . . p.52
Voltage Detector
3237,3238,3239 3120,3480-21
Multi-function type, 9999 High speed DMMs
count display (V range), 199999 count display
RS-232C communication,
True RMS rectifier (3805)
. . . . . . . . . . . . . . . p.54
Insulation Testers
3118-11 to -12
47
3801-50
Magnetic Field
HiTESTER
Voltage Detector
AC 70 to 600 V(50/60 Hz)
. . . . . . . . . . . . . p.50
Earth Testers
3453
Testing voltage 125V to 1000V,
Four ranges in one body,
Compact and lightweight, Digital
display, Comparator and memory
function
. . . . . . . . . . . . . . p.51
3454 -10/-11/-51
3455
. . . . . . . . . . . . . . p.52
. . . . . . . . . . . . . . p.51
Innovative and
low-cost Insulation
resistance tester with
continuity function
Testing voltage 250V
to 5000V, Five ranges
10 MΩ to 5 TΩ
Seven ranges
3151
Grounding resistance
meter, Two-wire or
three-wire measurement
method, Tough and
durable design
. . . . . . . . . . . . . . p.53
DIGITAL HiTESTERs
Table of functions
DC Voltage
ranges
Frequency
characteristics at
AC Voltage
AC Voltage
ranges
Resistance
ranges
DC Current
ranges
AC Current
ranges
Frequency
characteristics
at AC Current
Frequency
ranges
Continuity
3244
420mV to 500V,
5 ranges
Best accuracy:
±0.7% rdg. ±4 dg
4.2V to 500V, 4 ranges
Accuracy: ±2.3 % rdg.
±8 dgt.
Average rectifier
effective value
50 to 500 Hz
420Ω to 42 MΩ,
6 ranges
Best accuracy:
±2.0% rdg. ±4 dgt.
None
None
None
None
50Ω ±30Ω
3246
420.0mV to 600V,
5 ranges
Best accuracy:
±1.3 % rdg. ±4 dgt.
4.2V to 600V,
4 ranges
Accuracy:
±2.3% rdg. ±8 dgt.
Average rectifier
effective value
50 to 500 Hz
420.0Ω to 42.00MΩ,
6 ranges
Best accuracy:
±2.0 % rdg. ±4 dgt.
None
None
None
None
(50Ω±30Ω)
420.0mV to 1000V,
5 ranges
Best accuracy:
±0.5% rdg. ±2 dgt.
420.0mV to 1000V,
5 ranges
Best accuracy:
±1.2% rdg. ±3 dgt.
Average rectifier
effective value
420.0Ω to 42.00MΩ,
6 ranges
Best accuracy:
±0.7% rdg. ±2 dgt.
42.00µA to 10.00A,
6 ranges
Accuracy:
±1.5 % rdg. ±4 dgt.
42.00µA to 10.00 A,
6 ranges
Best accuracy:
±2.5 % rdg. ±5 dgt.
Average rectifier
effective value
0.50Hz to500.0kHz,
5 ranges
input level: 800mV
to 1000V rms
Accuracy:
±0.02% rdg. ±1 dgt.
50Ω ±30Ω or less
51mV to 1000V,
7 ranges
Best accuracy
3801-50: 0.025% rdg.
± 5dgt.
3802-50: 0.03% rdg.
± 5dgt.
51mV to 1000V,
7 ranges
Best accuracy
3801-50: 0.4% rdg.
± 25dgt.
3802-50: 0.6% rdg.
± 25dgt.
510µA to 10A
6 ranges
Best accuracy
3801-50: 0.05% rdg.
± 25 dgt.
3802-50: 0.1% rdg.
± 25 dgt.
510µA to 10A
6 ranges
Best accuracy
3801-50: 0.7% rdg.
± 20 dgt.
3802-50: 0.9% rdg.
± 25dgt.
3801-50:
20 to 100kHz
3802-50:
30 to 20kHz
99.999Hz to 999.99kHz
Best accuracy
0.02% rdg. ± 3 dgt.
10Ω or less
(at 510Ω range)
3803
400.0mV to 1000V,
5 ranges
Best accuracy:
±0.6% rdg. ±2 dgt.
400.0mV to 1000V,
5 ranges
Best accuracy:
±2.0% rdg. ±2 dgt.
Average rectifier
effective value
40 to 500Hz
400.0Ω to 40.00MΩ,
6 ranges
Best accuracy:
±0.6% rdg. ±3 dgt.
400.0µA to 10.00A,
5 ranges
Best accuracy:
±1.5 % rdg. ±2 dgt.
400.0µA to 10.00A,
5 ranges
Best accuracy:
±2.0 % rdg. ±2 dgt.
Average rectifier
effective value
40 to 500Hz
None
34.5Ω or less
(at 400Ω range)
3804
999.9mV to 999.9V,
4 ranges
Best accuracy:
±0.3% rdg. ±2 dgt.
999.9mV to 999.9V,
4 ranges
Best accuracy:
±1.2 % rdg. ±5 dgt.
Average rectifier
effective value
40 to 500 Hz
400.0Ω to 40.00MΩ,
6 ranges
Best accuracy:
±0.6 % rdg. ±3 dgt.
400.0µA to 10.00A,
6 ranges
Best accuracy:
±0.2 %rdg. ±3 dgt.
400.0µA to 10.00A,
6 ranges
Best accuracy:
±1.2 % rdg. ±5 dgt.
Average rectifier
effective value
50 to 2 kHz
None
10Ω or less
(at 400Ω range)
999.9mV to 999.9V,
4 ranges
Best accuracy:
±0.1% rdg. ±2 dgt.
999.9mV to 999.9V,
4 ranges
Best accuracy:
±1.1% rdg. ±5dgt.
Effective value rectifier
40 to 2 kHz
400.0Ω to 40.00MΩ,
6 ranges
Best accuracy:
±0.5 % rdg. ±3 dgt.
400.0µA to 10.00A,
6 ranges
Best accuracy:
±0.1%rdg. ±3dgt.
400.0µA to 10.00A,
6 ranges
Best accuracy:
±0.1 % rdg. ±5 dgt.
Effective value rectifier
50 to 2kHz
1Hz to 50kHz /
0.7V to 300V rms
Best accuracy:
±0.05% rdg. ±4 dgt.
10Ω or less
(at 400Ω range)
3255-50
420mV to 1000 V,
5 ranges,
Best accuracy:
±0.5 % rdg. ±4 dgt.
420mV to 1000 V,
5 ranges,
Best accuracy:
±1.2% rdg. ±4 dgt.
Average rectifier
effective value
None
(45Ω ±35Ω or less)
3030-10
0.3V (16.7kΩ/V),
3/12/30/120/300/
600V(20kΩ/V)
Accuracy:
±2.5% f.s.
12V±4% f.s. (9kΩ/V)
30/120/300/600V
±2.5% f.s.
Average rectifier
effective value
None
None
3256-50
3256-51
(3257)
3801-50
True RMS
3802-50
True RMS
3805
True RMS
50 to 500 Hz
510Ω to 510MΩ ,
7(6) ranges (3802-50)
3801-50: 20 to 100kHz Best accuracy
3802-50: 30 to 30kHz 3801-50: 0.05% rdg.
± 5 dgt.
3802-50: 0.08% rdg.
± 5 dgt.
50 to 500 Hz
None
420Ω to 42 MΩ,
6 ranges,
Best accuracy:
±0.7 % rdg. ±4 dgt.
0 to 3kΩ
(center scale 30Ω)
R×1, R×10, R×100,
R×1k
±3.0% of scale length
None
None
60µA/30m/300mA
(300mV internal
voltage drop)
Accuracy: ±3% f.s.
None
None
Included
accessories
CR2032×1 batteries
(Continuous use
150 hours)
55W×109H×
9.5D mm/60g
Hard case(1)
CR2032×1 batteries
(Continuous use
150 hours)
30W×182H×
26.5D mm
80 g
R03(AAA)×
2 dry batteries
(Continuous use
100 hours)
76W×167H×
33D mm/260 g
TEST LEAD 9170(1)
Fuse(2)
CARRYING CASE
9378 (1) (3256-50)
Holster (3256-51)
6LR61×1 (9.0V)
(Continuous
use 50 hours)
90W×192H×
37D mm/940 g
TEST LEAD
3851-10(1),
Holster(1)
6F22(006P)×1
76W×167H×
33D mm
400 g
TEST LEAD 3851-10(1)
Holster(1)
3 times/sec
13 times/sec
(Bar graph)
6F22(006P)×1
76W×167H×
33D mm/400 g
TEST LEAD 3851-10(1)
Holster(1)
3 times/sec
(exclusive Hz range)
1 time/sec
(Hz range)
13 times/sec
(Bar graph)
6F22(006P)×1
76W×167H×
33D mm/400 g
TEST LEAD 3851-10(1)
Holster(1)
R03(AAA)×2
dry batteries
(Continuous use
200 hours)
70 mmW×
145 mmH×
31 mmD/200 g
TEST LEAD
9207-10 (1),
CARRYING CASE
9371 (1)
95W×141H×
39D mm
280g
TEST LEAD 9207(1)
fuse(1)
CARRYING CASE
9390 (1)
Auto power
save
Range
switching
Display/Safety
3244
None
None
(Cancel impossible)
Auto
Digital/LCD,
maximum 4199 dgt
Safety: IEC1010-1,
Pollution degree 2,
over voltage category II
None
2.5 times /sec
3246
judgement only
(3.4V open
terminal voltage)
None
(Cancel possible)
Auto or Manual
Digital/LCD,
with Back light
max. 4199 dgt.
None
2.5 times/sec
3256-50
3256-51
(3.4 V open
terminal voltage)
Voltage detect
function
(Cancel possible)
Hold-auto function
Relative function
Auto or Manual
LCD, maximum
4200 dgt. (all mode)
maximum 19999 dgt.
(Frequency)
3801-50 only:
AC+DC measurement,
Pulse output
Common functions:
Capacitance, Data hold,
(3.1 V open
terminal voltage) dBm measurement, (Cancel possible)
Duty ratio/Pulse width,
Temperature,
1ms peak hold
Relative, Max/Min/Ave,
RS-232C, USB
Auto or Manual
LCD, max.
51000 dgt.
with Back light
3803
(3 V open
terminal voltage)
(Cancel possible)
Auto or Manual
LCD, max.
4000 dgt.
(Maximum
41 dots)
2.5 times/sec
13 times/sec
(Bar graph)
3804
Capacitance,
Data hold, Refresh
(3.3 V open
hold, Max/Min/Ave/
terminal voltage) Relative/4-20mA% (Cancel possible)
display, RS-232C
Auto or Manual
LCD, max.
4000 dgt.
max. 9999 dgt.
(at V range)
(Maximum
41 dots)
3805
(3.3 V open
terminal voltage)
Capacitance,
Data hold, Refresh
hold, Max/Min/
Ave/Relative/
4-20mA% display,
RS-232C,
Temperature
(Cancel possible)
Auto or Manual
LCD, max. 4000 dgt.
max. 9999 dgt.
(at V range)
(Maximum
41 dots)
3255-50
judgement only
(3.4 V open
terminal voltage)
CLAMP (ACA)
function
(Clamp-on probe :
Option)
10A to 1000A
7ranges
(Cancel possible)
Auto or Manual
LCD, maximum
4199 dgt.
None
None
Manual
Indicator type
None
True RMS
3802-50
True RMS
True RMS
3030-10
RS-232C,
Data hold
Battery check:
0.9 to 1.8V, load
resistance 10Ω
(3V open terminal Temperature:
-20 to 150,
voltage)
(Thermister Temperature
Probe 9021-01 is
necessary, sold separately)
(Maximum
40 segments)
Sampling rate
2.5 times/sec
(all mode)
5 times/sec
(Frequency)
25 times/sec
(Bar graph)
Maximum 21 dots 3.75 times/sec
2.5 times/sec
None
Power supply
R6P(AA)×2
batteries
Field Measuring Instruments
Dimensions/
mass
Other functions
3801-50
Bar graph
display
None
Diode check
(3257)
50 to 500Hz
48
PENCIL HiTESTER
3246
Pencil-type DMM with Penlight
In addition to being compact, this pencil-type tester comes with autorange and data hold functions for incredibly easy
measurement of electrical and electronic circuitry.
●Full-auto ranging, 4199 count display
●Penlight brightly illuminates test points
●Overload protection to 600 V
(Ω and continuity functions)
Penlight brightly illuminates test points
OPTIONS
10A SHUNT *9081
*Note: Non-CE mark product
CAT III 600 V
3244
CARD HiTESTER
Card size DMM with emphasis on safety
●Only 9.5 mm thick and 60 g in weight
●4199 count display
●Test leads fit neatly inside the case.
●Automatic power saving function saves your
batteries even when you forget to turn off the power.
CAT II 500 V
OPTIONS
10A SHUNT *9081
*Note: Non-CE mark product
DIGITAL HiTESTER
3801-50
CAT IV 600 V
CAT III 1000 V
OPTION
High-precision, high-resolution, and
multi-functional handy DMMs
Field Measuring Instruments
●Display two different parameters simultaneously
●Optional RS-232C or USB package for transferring data
captured by the 3801-50 to a PC
●Measures the AC components in DC voltage or DC current
●1ms peak hold mode makes it possible to capture the peak
value of a waveform
DIGITAL HiTESTER
OPTIONS
CARRYING CASE
3853
COMMUNICATION PACKAGE (RS-232C) 3856-01
COMMUNICATION PACKAGE (USB)
3856-02
TEMPERATURE PROBE
*9180 to *9183
TEMPERATURE PROBE
9472 to 9476
CLIP ON BASE
*9617
(for capacitance measurement)
CLIP TYPE LEAD
*9618
(for capacitance measurement)
*Note: Non-CE mark product
3803
Compact and basic DMM
●4000 count display full scale
●Average rectified RMS indication type
●Optional RS-232C package for transferring data
captured by the 3803 to a PC
OPTION
CAT III 600 V
CAT II 1000 V
OPTIONS
CARRYING CASE
3853
RS-232C PACKAGE
3854
HIGH-VOLTAGE PROBE *9014
*Note: Non-CE mark product
49
OPTION
DIGITAL HiTESTER
3256-50/-51 3257-50/-51
Terminal shutter interlock mechanism
●Terminal shutter interlock
mechanism exposes only the
correct terminals for connection
in the currently selected function
●Wide range, maximum reading
4200 digit
●High-speed response, bar graph
display
●Conforms with IEC1010
●Hold-auto function automatically
displays voltage or current value
and resistance value
3256-50/-51
CAT II 1000 V
CAT III 600 V
3257-50/-51
CAT III 1000 V
CAT IV 600 V
Fail-safe!
Shutter mechanism prevents incorrect test lead connection
Single
operation
3257-50
(True RMS)
Simple
operation
with rotary
switch
Voltage ranges
3256-51
10A range
Only V and COM terminals open
Only A and COM terminals open
* The above photograph shows a special model with a transparent cover.
Check for live lines safely and easily
In the AC V range, the 3256-50 can be used to
check whether power lines are live. When the
sensitivity level is set to 4 and the test head is
placed near a live power line, the built-in buzzer
sounds and a display indicator lights.
Sensitivity threshold: 100 V AC or higher
Model
(Standard type)
(3256-50 with holster)
(Standard type)
(3257-50 with holster)
3256-50
3256-51
3257-50
3257-51
OPTIONS
HIGH-VOLTAGE PROBE
*9014
CARRYING CASE (for 3256-51) 3853
*Note: Non-CE mark product
DIGITAL HiTESTER
3255-50
Tough for use on industrial power lines
CAT II 1000 V
CAT III 600 V
●Built-in current limiter and fuse capable of withstanding 1000 V to
prevent short-circuit accidents
●Wide range, maximum reading 4199 digit
●Two-terminal configuration eliminates the need for probe reconnections
●Industrial grade test leads for enhanced safety
TEST LEAD 9207-10
(Supplied as standard with the 3255-50)
CARRYING CASE 9371
(Supplied as standard with the 3255-50)
3120 3480-21
Twin Light Audible Voltage Detector
●Green for Battery Check
●Red for Voltage Detection
SPECIFICATIONS
Model
3480-21 (for 200V Installations)
3120 (for 100V Installations)
Measurement Function
Voltage Detection
Voltage Detection
Voltage Range
AC 90 to 600 V, 50/60 Hz
AC 70 to 600 V, 50/60 Hz
Indication
Red LED and continuous
beeping sound
Red LED and continuous
beeping sound
Battery Check
Green LED
Green LED
LR44 Button alkaline batteries × 2
AAA manganese(R03) or
alkaline(LR03) batteries × 2
Continuous Use
approx. 15 hours
approx. 200 hours
Dimensions, mass
20W × 126H × 15D mm, 25 g
149 mmH × φ18.5 mm, 38 g
Power supply
Field Measuring Instruments
VOLTAGE DETECTOR
OPTIONS
3480-21
3120
CAT IV 600 V
50
3455
HIGH VOLTAGE INSULATION HiTESTER
Maximum 5kV Test Voltage - Up to 5TΩ of Insulated Resistance Testing
Safely evaluate the insulation characteristics of high voltage transformers, motors and cables
●Wide voltage range (250V to 5kV) for maximum 5TΩ of insulation resistance measurements
●Automatically calculate and display the PI (Polarization Index) and DAR (Dielectric
Absorption Ratio) for all types of insulation evaluations
●Temperature compensation to accurately respond to variations in insulation material
●Internal memory stores 100 blocks of manually recorded data and 10 sets of log data
●USB interface, compact rugged case, and safe design
CAT III 600 V
SPECIFICATIONS
0.00 MΩ to 250 GΩ,
250 V range
Accuracy : ±5 % rdg. ±5 dgt. (0 to 2.50 GΩ)
±20 % rdg. ±5 dgt. (2.50 to 250 GΩ)
0.00 MΩ to 500 GΩ ,
500 V range
Accuracy : ±5 % rdg. ±5 dgt. (0 to 5.00 GΩ)
±20 % rdg. ±5 dgt. (5.00 to 500 GΩ)
0.00 MΩ to 1.00 TΩ ,
1 kV range
Accuracy : ±5 % rdg. ±5 dgt. (0 to 10.0 GΩ)
±20 % rdg. ±5 dgt. (10.0 to 500 GΩ)
±30 % rdg. ±50 dgt. (500 G to 1.00 TΩ)
0.00 MΩ to 2.50 TΩ,
2.5 kV range
Accuracy : ±5 % rdg. ±5 dgt. (0 to 25.0 GΩ)
±20 % rdg. ±5 dgt. (25.0 to 500 GΩ)
±30 % rdg. ±50 dgt. (500 G to 2.50 TΩ)
0.00 MΩ to 5.00 TΩ ,
5 kV range
Accuracy : ±5 % rdg. ±5 dgt. (0 to 50.0 GΩ)
±20 % rdg. ±5 dgt. (50.0 to 500 GΩ)
±30 % rdg. ±50 dgt. (500 G to 5.00 TΩ)
Insulation resistance mode: Data memory(100 data), measurement value hold, average, bar graph display, timer etc.
Functions
Leak current: (1.00nA to 1.20mA), Temperature: (-10°C to 70°C)
Voltage: (DC±50V to 1kV AC 50V to 750V)
All measurement mode: live wire warning, battery indicators, auto power save
USB ver 2.0 (full speed)
Interface
Display
LCD with backlight
Power supply
LR6(AA) alkaline batteries × 6, 9459 BATTERY PACK
9753 AC ADAPTER
260 W × 250.6 H × 119.5 D mm, 2.8 kg
Dimensions, mass
Accessories
OPTIONS
TEST LEAD (red, black, blue 3m)
ALLIGATOR CLIPs (red, black, blue)
TEMPERATURE SENSOR (1m)
TEMPERATURE SENSOR (6cm)
TEST LEAD (red, black, blue 10m)
BATTERY PACK
AC ADAPTER
TEST LEAD (red, black, blue 3m) 9750-01 to 03,
ALLIGATOR CLIPs (red, black, blue),
LR6(AA) Alkaline batteries (6), USB CABLE(1)
DIGITAL MΩ HiTESTER
9750-01 to 03
9751-01 to 03
9631-01
9631-05
9750-11 to 13
9459
9753
3453
For efficient insulation measurement!
Field Measuring Instruments
●One body with four ranges: 125 V/40 MΩ, 250 V/2000 MΩ, 500 V/2000 MΩ,
and 1000 V/4000 MΩ
●Accurate digital display
●Insulation measurement through sight and sound
●Memorizes on the spot (Memorizes up to 20 data points)
●Recognizes variations of resistance
●Ability to measure AC voltage and low resistance (continuity)
CAT III 600 V
SPECIFICATIONS
Common SPECIFICATIONS
Testing voltage
125 V DC
250 V DC
500 V DC
1000 V DC
Measurement range
4.000 MΩ or 40.00 MΩ 4.000 /40.00 /400.0 /2000 MΩ, (+ 4000 MΩ range at 1000 V mode)
First
±2 % rdg. ±3 dgt.
±2 % rdg. ±3 dgt.
±2 % rdg. ±3 dgt.
±2 % rdg. ±3 dgt.
effective measurement range at 0.100 to 10.00 MΩ at 0.200 to 20.00 MΩ at 0.200 to 50.00 MΩ at 0.200 to 999 MΩ
Discharge function : effective
Display : Digital/4000 dgt. LCD, Bar graph/42 seg.
with backlight
Functions : Insulation resistance mode: comparator, memory
Second
±5 % rdg.
±5 % rdg.
effective measurement range at 10.01 to 40.00 MΩ at 20.01 to 2000 MΩ
Voltage with no load
Min. resistance measurement value
(Resistance value to maintain rated voltage)
Shorting measurement
current
±5 % rdg.
at 50.1 to 2000 MΩ
±2 % rdg. ±6 dgt.
at 0 to 0.199 MΩ
±5 % rdg.
at 1000 to 4000 MΩ
Not more than 1.2 times rated testing voltage
0.125 MΩ
0.250 MΩ
1.2 mA max.
0.500 MΩ
2.000 MΩ
0.6 mA max.
Response time
Infinitude to center, infinitude to zero-MΩ within 5 second (within accuracy range)
Low resistance (continuity) ±2 % rdg. ±8 % dgt. at 0 to 400.0Ω (aural warning below: 30Ω), Open terminal voltage: 4 V max.
±3 % rdg. ±8 dgt. at 0 to 600 V, 50 to 60 Hz,
AC voltage range and
Input resistance: 170 kΩ
accuracy
51
(20 data), measurement value hold, auto discharge, bar graph display
(measurement switch ON: insulation resistance; measure switch OFF:
voltage across measurement terminals), auto display of measurement
value 1 minute after measurement start, All measurement mode: live
wire warning, battery indicators, auto power save
Sampling rate : 2 times/second
Power supply : R6P(AA) ×4 or LR6(AA)×4
Dimensions : 155W×98H×80D mm, 500g
Accessories : TEST PROBE 9294(1)
display cover and suspension band(1)
OPTIONS
TEST PROBE *9289
BREAKER PIN *9288
*Note: Non-CE mark product
DIGITAL MΩ HiTESTER
3454-10/-11/-51
CAT III 600 V
3454-11/-51
Revolutionary insulation resistance tester with
continuity function all in one low price
SPECIFICATIONS
Model
Insulation testing voltage
Measurement range
Insulation Accuracy
resistance
Voltage with no load
Short circuit current
Response time
Low resistance (continuity)
AC voltage
Test voltage: 250V / 500V / 1000V DC
(3454-51: Non-CE mark product)
3454-10
3454-11/51
50 V DC / 125 V DC / 250 V DC / 500 V DC
250 V DC / 500 V DC / 1000 V DC
4.000/40.00/400.0/200.0 MΩ,400.0/2000 (250V/500V range only) MΩ
4.000/40.00/400.0/500.0 MΩ, 4000 (1000V range only) MΩ
1st effective range: ±3 %rdg. ±4 dgt. / 2nd effective range: ±5 %rdg. ±5 dgt.
Not more than 1.2 5 rated measurement voltage
1.2 mA max.
∞ to center, ∞ to 0 MΩ within 5 s (within accuracy range)
Measurement range: 40.00 / 400.0 / 4.000 k / 40.00 k / 400.0 k / 4.000 MΩ Short circuit current: 200 mA
Accuracy: ±3 %rdg. ±6dgt. (±5 %rdg. ±6dgt. at 400 kΩ range or higher) Open terminal voltage: 4 to 6 V Response time: 5 s max.
Display indication range: 0 to 750 V Accuracy: ±3 %rdg. ±6 dgt.(up to 600V), Frequency range: 50 / 60 Hz, Input impedance: 100kΩ
OPTIONS
TEST PROBE
9294
BREAKER PIN
*9288
TEST PROBE
*9289
*Alligator Clips for Model 9289
CONNECTOR CORD 9257
*Note: Non-CE mark product
Accessories : TEST PROBE (for 3454-11/3454-10) 9294, TEST PROBE 9289. Alligator Clips (for 3454-51), Strap band (1)
●Other functions: Insulation and low resistance mode - comparator, measurement value hold; Insulation resistance mode - auto discharge;nsulation and AC voltage mode - live wire warning (when voltage
of 70V ±10V exists across measurement terminals); Low resistance mode - zero adjust; All measurement modes - battery indicators, auto power save
●Display update rate: 2 times / second
●Power source: R6P manganese battery×4 or LR6 alkaline battery×4
●Dimensions and Mass: Approx. 175 W×148 H×56 D mm; Approx. 530g (with display cover closed)
MΩ HiTESTER
3451-11 to 3451-15
Compact and lightweight for perfect portability
CAT III 600 V
Common SPECIFICATIONS
SPECIFICATIONS
Model
3451-11
3451-12
3451-13
Testing voltage
125 V DC
250 V DC
500 V DC
Rated resistance
20 MΩ
50 MΩ
100 MΩ
±5 % of scale
±5 % of scale
±5 % of scale
First effective
measurement range and indication at 0.02 MΩ indication at 0.05 MΩ indication at 0.1 MΩ
to 10 MΩ
to 20 MΩ
to 50 MΩ
tolerances
±10 % of scale
±10 % of scale
±10 % of scale
Second effective
measurement range and indication at more than indication at more than indication at more than
10 MΩ to 20 MΩ 20 MΩ to 50 MΩ 50 MΩ to 100 MΩ
tolerances
Excepting 1st and 2nd
effective measurement
range include 0 MΩ &
infinity indication
Shorting measurement
current
Scale center indication
AC voltage scale and
tolerances
3451-14
3451-15
500 V DC
1000 MΩ
1000 V DC
2000 MΩ
±5 % of scale
indication at 1 MΩ
to 500 MΩ
±10 % of scale
indication at more than
500 MΩ to 1000 MΩ
±5 % of scale
indication at 2 MΩ
to 1000 MΩ
±10 % of scale
indication at more than
1000 MΩ to 2000 MΩ
0.7 % of scale length
0.7 % of scale length
0.7 % of scale length
0.7 % of scale length
0.7 % of scale length
1.2 mA max.
1.2 mA max.
1.2 mA max.
0.6 mA max.
0.6 mA max.
0.5 MΩ
0 to 250 V
(50/60 Hz)
±5 % f.s. at
1 MΩ
0 to 300 V
(50/60 Hz)
±5 % f.s. at
2 MΩ
0 to 500 V
(50/60 Hz)
±5 % f.s. at
20 MΩ
0 to 500 V
(50/60 Hz)
±5 % f.s. at
50 MΩ
0 to 500 V
(50/60 Hz)
±5 % f.s. at
Discharge function : effective
Power supply : R6P(AA)×4
Dimensions, mass :
152W×95H×47D mm, 420 g
Accessories :
TEST PROBE 9292(1)
CARRYING CASE 9384(1)
Safety rating :
Conformance to IEC1010, pollution
degree 2, installation category III
OPTIONS
BREAKER PIN
*9288
PIN TYPE EARTH PROBE 9293
*Note: Non-CE mark product
3452
3452-13
Compact analog three-range insulation resistance meter
CAT III 600 V
Common SPECIFICATIONS
SPECIFICATIONS
Model
Testing voltage
Rated resistance
First effective
measurement range and
tolerances
3452-11
3452-12
3452-13
at 0.01 MΩ
to 5 MΩ
at 0.01 MΩ
to 5 MΩ
at 0.02 MΩ
to 10 MΩ
at 0.02 MΩ
to 10 MΩ
at 0.05 MΩ
to 20 MΩ
at 0.1 MΩ
to 50 MΩ
±5 % of scale indication
±10 % of scale indication
Second effective
measurement range and at 5 M to 10 MΩ, at 5 M to 10 MΩ, at 10 M to 20 MΩ, at 10 M to 20 MΩ, at 20 M to 50 MΩ, at 50 M to 100 MΩ,
tolerances
0.005M to 0.01MΩ 0.005M to 0.01MΩ 0.01M to 0.02MΩ 0.01M to 0.02MΩ 0.02M to 0.05MΩ 0.05M to 0.1MΩ
0MΩ & infinity indication
0.7 % of 100 V scale length
0.7 % of 500 V scale length
Open-circuit terminal voltage
Not more than 1.2 times rated testing voltage
Not more than 1.2 times rated testing voltage
Rated measurement current
1 m to 1.2 mA
1 m to 1.2 mA
Shorting measurement current
Scale center indication
AC voltage scale & tolerances
Discharge function : effective
Power supply : R6P(AA)×4
Dimensions, mass :
152W×95H×47D mm, 420g
Accessories :
at 0.1 MΩ
at 0.05 MΩ
at 2 MΩ
TEST PROBE 9292(1)
to 20 MΩ
to 50 MΩ to 1000 MΩ
CARRYING CASE 9384(1)
±10 % of scale indication
Safety rating :
at 20 M to 50 MΩ, at 50 M to 100 MΩ, at 1000 M to 2000 MΩ,
Conformance to IEC1010,
0.02M to 0.05MΩ 0.05M to 0.1MΩ
1 M to 2 MΩ
pollution degree 2,
installation category III
0.7 % of 1000 V scale length
25 V DC 50 V DC 100 V DC 125 V DC 250 V DC 500 V DC 250 V DC 500 V DC 1000 V DC
10 MΩ
10 MΩ
20 MΩ
20 MΩ
50 MΩ
100 MΩ
50 MΩ
100 MΩ 2000 MΩ
±5 % of scale indication
±5 % of scale indication
±5 % of scale indication
1.2 mA max.
1.2 mA max.
0.2 MΩ
0.2 MΩ
0.5 MΩ
±5 % f.s. at 0 to 150 V (50/60 Hz)
0.5 MΩ
1 MΩ
2 MΩ
±5 % f.s. at 0 to 500 V (50/60 Hz)
Not more than 1.2 times rated testing voltage
1 m to 1.2 mA
0.5 m to 0.6 mA
1.2 mA max.
0.6 mA max.
1 MΩ
2 MΩ
50 MΩ
±5 % f.s. at 0 to 500 V (50/60 Hz)
Field Measuring Instruments
MΩ HiTESTER
-11 to
OPTIONS
BREAKER PIN
*9288
PIN TYPE EARTH PROBE 9293
*Note: Non-CE mark product
52
EARTH HiTESTER
3151
Stable measurement for earth resistance
●Measurement range for grounding resistance increased to 115 % of normal range
●Elastomer rotary knob fits the hand perfectly.
●Select the "simple" two-wire measurement method, using a low ground
conductor such as the ground side of a commercial power supply, or the
conventional three-wire measurement method
●Select a measurement frequency to reduce the influence of harmonics of the
power supply frequency on the ground current
SPECIFICATIONS
Grounding resistance, Grounding voltage
Measurement item
Measurement ranges 10Ω (0 to 11.5Ω) to 1000Ω (0 to 1150Ω), 3 ranges
30V (0 to 30 VAC), 1 range
*Using the two-wire measurement method; applied to 100Ω /1000Ω range only.
Operating method
AC phase difference
Open terminal voltage 50V AC max.
Measurement current 15mA AC max. *3mA AC max. using two-wire method.
Measurement frequency 575Hz or 600 Hz selectable
Basic accuracy
Grounding resistance: ±2.5% f.s.
Grounding voltage: ±3% f.s.
Power supply
R6P (AA), 6 pieces (at least 500 operations)
or LR6 (AA), 6 pieces (at least 1400 operations)
*Operating time: 30 second measurement, 30 second off
Dimensions, mass
164W×119H×88D mm, 800g (main unit only)
Accessories
AUXILIARY EARTHING ROD(2) 9214,
MEASURING CABLE 9215
(one earth: black 5m, yellow 10m, red 20m, 9216 CABLE WINDER: 3),
CARRYING CASE 9393(1)
OPTIONS
EARTH NET (set of two) 9050
*Use in location where there is no driven-in ground and where water seepage is present
PHASE DETECTOR
3129 3129-10
Non-Metallic Contact for Optimal Safety
SPECIFICATIONS
Phase detection(positive, negative), live wire check(R-S/S-T
only)
Voltage Detection Method Electrostatic induction method
70V to 600V AC(50/60Hz)(sine wave, continuous input)(3129)
Voltage Range
70V to 1000V(3129-10)
2.4 to 17mm max.(3129) 10 to 40mm(3129-10)
Clamp Diameter
Positive:4 LEDs lit in clockwise order and
3 short beeps
Phase Detection
Negative:4 LEDs lit in counterclockwise
Display
order and one continuous beep
R-S and S-T lamps will light if voltage
Live Wire Check
between wires are within voltage range
ON lamp blinks to indicate battery low status when
Battery Check
instrument is turned on
Function
Auto shut off if no activity is detected after power is turned
Auto Power Off
ON for 15 minutes
Two "AA" size batteries; rated voltage:DC3.0V; maximum rated
Power Supply
power:300mVA; continuous use:approx.70 hours(standby)
70W×75H×30D mm, 200g; Cord length:0.7m (3129)
Dimensions, Mass
240g (3129-10)
Carrying case(1), strap(1), R6P manganese battery(2), spiral tube(1)
Accessories
Measurement Function
TACHO HiTESTER
Field Measuring Instruments
Precise rotation speed meter
3129
3129-10
CAT IV 600 V
3403 3404
3403
3404
53
CAT III 600 V
3403: SPECIFICATIONS
Measurement ranges r/min: rotation per minute, r/s: rotation per second
r/min: (30.00 to 199.99)range to (20000 to 99990)range, 4 ranges,
r/s: (0.5000 to 1.9999)range to (200.0 to 1600.0)range, 4 ranges
Sampling period
0.5 second to 2 seconds
Detection distance
Distance of 50 mm to 200 mm
Analog output
None
Power supply
R6P (AA) × 4 (continuous use of 17 hours) or AC Adapter
(6 V, 300 mA)
Dimensions, mass
62W × 180H × 38D mm, 260 g
Accessories
REFLECTIVE TAPE(1Sheet) 9211, Carrying case(1)
3404: SPECIFICATIONS
Measurement ranges r/min: (30.00 to 199.99)range to (20000 to 99990)range, 4 ranges
(at slow sampling mode)
r/s: (0.5000 to 1.9999)range to (200.0 to 1600.0)range, 4 ranges
(at slow sampling mode)
Total: Total rotation counts from 0 to 599999
Period: Measure rotation pulses from 600µs to 2 sec.
Sampling period
Slow: 0.5 sec. to 2 sec., Fast: 0.1 sec. to 0.5 sec.
Detection distance
Distance of 50 mm to 200 mm
Analog output
1V DC at full-scale range output
Power supply
R6P (AA) × 4 (continuous use of 16 hours) or AC Adapter (6 V, 300 mA)
62W × 180H × 38D mm, 260 g
Dimensions, mass
REFLECTIVE TAPE (1Sheet) 9211, OUTPUT CORD 9094(1),
Accessories
Carrying case (1)
BATTERY HiTESTER
3554
The New Standard for Assessing Deterioration of
Lead-acid Batteries
●Ideal for testing UPS batteries
●Auto Hold and Auto Memory
●Store up to 4800 sets of battery data
●Averaging function
STANDARD
SPECIFICATIONS
Resistance Range
Accuracy
Voltage Range
Accuracy
Temperature Measurement Range
Accuracy
Measurement Frequency
3.100m/31.00 m/310.0 m/3.100 Ω
±0.8 %rdg.±6 dgt.; 3.000 mΩ range only: ±1.0 %rdg.±8 dgt.
±6.000 V/60.00 V
±0.08 %rdg.±6 dgt.
-10.0°C to 60.0°C (when used with 9460)
±1°C
1 kHz ± 30 Hz
150 mA (3 m/30 mΩ), 15 mA(300 mΩ), 1.5 mA(3 Ω);
Measurement Current (Range)
Open terminal voltage: 5 V max.
Max. Allowable Voltage 60V DC (No AC input allowed)
Primary and secondary resistance limits, minimum voltage limit
Comparator
No. of Comparator Settings 200
4800 sets(date & time, resistance, voltage, temperature,
Data Storage
comparator value, judgement decision)
USB (with bundled software for data transfer to PC)
PC interface
AA (LR6) Alkaline Batteries × 8 for up to 10 hours of
Power Supply
continuous use
192W×121H × 55D mm, 790 g
Dimensions & Mass
9465-10 PIN TYPE LEAD (1), USB cable (1), Application
software CD (1), Carrying case (1), Strap (1), LR6 alkaline
Accessories
batteries (8), Replacement fuse (1), Zero adjustment board
(1)
OPTIONS
PIN-TYPE LEAD
(Standard accessory)
9465-10
PIN-TYPE LEAD
(Option)
9772
BATTERY HiTESTER
9460
9772
9466
*9467
9465-90
9772-90
9465-10
3555
3550, 3551:
SPECIFICATIONS
Instantaneous
determination
of battery deterioration
Resistance Measurement
3550: 30 mΩ to 3Ω, 3 ranges, 10µΩ resolution max.
3551: 3 mΩ to 300 mΩ, 3 ranges, 1µΩ resolution max.
●Ideal for
testing
compact storage
batteries
Voltage
Measurement
3 or 30
V DC, 2 ranges, 1 mV resolution max.
●Three-rank
ratingMeasurement
of battery state:
Pass,1 range,
Warning,
or Fail (platinum sensor)
Temperature
-10 to 60°C,
0.1°C resolution
Sampling rate
0.83 times/second
Setting: Upper and lower limit for resistance, and lower limit for
Comparator functions
voltage, Output: LED, beep
Other functions
Data memory, Printer interface (9203 or Centronics)
Power supply
3550: LR6(AA)×6, 3551: LR6(AA)×6, or 9418-10
3550: 196W×130H×50D mm, 710 g (including batteries)
Dimensions, mass
3551: 196W×130H×65D mm, 860 g (including batteries)
Accessories
3550: CLIP-TYPE LEAD WITH TEMPERATURE 9460
SENSOR(1), CARRYING CASE 9382(1), Dust cover(1), LR6(6)
3555
3551: PIN-TYPE LEAD 9465(1), REMOTE CONTROL 9466
SWITCH(1), CARRYING CASE 9377 (1), Dust cover(1), LR6(6)
3030-10
Basic tester with improved safety features
3555: SPECIFICATIONS
Resistance Measurement 300 mΩ to 30Ω, 3 ranges, 100µΩ resolution max.
Voltage Measurement 3 or 30V DC, 2 ranges, 1 mV resolution max.
Sampling rate
1.25 times/second
Setting: Upper and lower limit, for resistance, and lower
Comparator functions
limit for voltage, Output: LED, beep
Power supply
LR6(AA), 6 pieces (Continuous use of 18 hours)
Dimensions, mass
196W×130H×50D mm, 680g (including batteries)
Accessories
9461 PIN-TYPE LEAD (1), LR6 (6)
OPTIONS
LARGE CLIP TYPE LEAD
PIN TYPE LEAD
CLIP TYPE LEAD
CARRYING CASE
*1Note: The 9455 probe is a precision instrument. Exercise appropriate care when handling it.
*2Note: Non-CE mark product
SPECIFICATIONS
DC Voltage range
AC Voltage range
Resistance range
DC Current range
●Protected against transient voltages up
to 250 V AC, preventing electric shock
accidents before they can happen
●Drop proof design withstands dropping
onto a concrete floor from a height of 1
meter
●LED check function
●Temperature measurement support (with
optional probes)
●CE marking
*2 9467
*1 9455
9287-10
9382
Other functions
Safety considerations
Power supply
Dimensions, mass
Accessories
Field Measuring Instruments
HiTESTER
CLIP TYPE LEAD Temperature Sensor
PIN TYPE LEAD Lead
REMOTE CONTROL SWITCH
LARGE CLIP TYPE LEAD (non CE mark)
TIP PIN (for 9465-10)
TIP PIN (for 9772)
PIN TYPE LEAD (bundled with standard 3554)
0.3 V (16.7 k-ohm/V), 3/12/30/120/300/600 V (20 k-ohm/V)
Accuracy: ±2.5 % f.s.
12 V (9 k-ohm/V) Accuracy: ±4 % f.s.
30/120/300/600 V (9 k-ohm/V) Accuracy: ±2.5 % f.s.
Average rectifier effective value
0 to 3 k-ohm ( center scale 30 ohm), R × 1, R × 10, R × 100, R × 1 k
±3 % of scale length
60 µA/30 m/300 mA (150 mV internal voltage drop)
Accuracy: ±3 % f.s.
Battery check: 0.9 to 1.8 V, load resistance 10 ohm
Temperature: -50 to 150 °C ( 9021-01 Thermister
Temperature Probe is necessary, sold separately)
Complies with EN61010-1:1992+A2:1995,
EN61010-2-031:1994, Installation Category III (anticipated
transient overvoltage 6000 V), Pollution Degree 2
R6P(AA) × 2 batteries
3555:
95 mm(3.74 in)W × 141 mm(5.55
in)H × SPECIFICATIONS
39 mm(1.54 in)D,
280 g (9.9 oz)
TEST LEAD 9207 (1), fuse (1), CARRYING CASE 9390 (1)
OPTIONS
CAT III 600V
TEST LEAD 9207 (Supplied as standard with the 3030-10)
TEST LEAD 9207-10 (Not compatible with the standard case for the 3030-10)
THERMISTER TEMPERATURE PROBE 9020-01 for temperature measurement
*HIGH-VOLTAGE PROBE 9017 up to 30 kV DC
CARRYING CASE 9390 (Supplied as standard with the 3030-10), plastic case
*Note: Non-CE mark product
54
LAN CABLE HiTESTER
Identify the 3 most important criteria for proper
networking at a glance
●Wire map check : Detect split pairs with wiring check
●Cable length : Get NVP-Enhanced measurement accuracy
●Direction check : Identify up to 21 cable destinations
3665-20
SPECIFICATIONS
Twisted-pair cable
Measurable cable
100ohm characteristic impedance, shielded and unshielded,
CAT 3, 4, 5, 5e and 6
Compatible connectors RJ-45 plugs
Wiring condition and shielding can be confirmed using the
WireMap check
HIOKI TERMINATOR 9690
Detectable errors: open, short, reversed, transposed, split pairs
and other miswiring
Measurable lengths: 2 to 300 m, 6.6 to 984 ft
Cable length check
Measurement accuracy: ± 4% rdg. ± 1 m, ± 4% rdg. ± 3.3 ft
Display resolution: 0.1 m, 0.3ft
Up to 21 cables can be identified using the supplied
Direction check
TERMINATOR 9690 and optional Models 9690-01 to 9690-04
128 x 64 dot matrix LCD (with backlight)
Display
Auto Backlight: pressing a button turns the backlight on (it
Functions
turns off automatically after about 20 seconds)
Beeper: sounds when pressing buttons and when measurement
results are displayed
Energy-Saving Mode: enter into energy-saving mode after
measurement (and resume when the TEST button is pressed)
Auto Power Save: the 3665-20 turns off automatically about
10 minutes after the last button press
Battery Check: Battery indicator blinks when voltage falls
below 2.4 V
Unit Switch: Select between meters or feet
Two AA-size (LR6) alkaline batteries 1.4VA Approx. 50 hours
Power supply
Dimensions, mass
Approx. 85 W × 130 H × 33 D mm, approx. 160 g
TERMINATOR 9690 (1)
Accessories
CARRYING CASE(1) (Stores the HiTESTER 3665-20 and
TERMINATORs 9690)
OPTIONS
TERMINATOR 9690-01 (IDs 1 to 5)
TERMINATOR 9690-02 (IDs 6 to 10)
TERMINATOR 9690-03 (IDs 11 to 15)
TERMINATOR 9690-04 (IDs 16 to 20)
CARRYING CASE 9249 (stores the 3665-20, 9690 and 9628 together)
LAN CABLE 9628 (1 m long, with RJ-45 plugs)
OPTICAL POWER METER
LASER LIGHT SOURCE
3661-20
3662-20 3663-20
Test for Optical Loss in Fiber Optic Cables
Field Measuring Instruments
3661-20 SPECIFICATIONS
Measurement functions Optical power measurement (dBm)
Measure absolute value of input optical power
Optical loss measurement (dB)
Automatically compare measured power with previously input reference
value to calculate and display loss
Calibration wavelength 850 nm, 1310 nm, 1550 nm
-60 dBm to +9 dBm (auto range)
Range
±0.22 dB (±5 %) at -10dBm, CW, 23°C ±5°C
Accuracy
FC, SC (using optional connector adapter)
Connector
Single mode, multi mode (core dia. 62.5µm max. NA: 0.275 max.)
Fiber type
InGaAs (dia. 1 mm)
Light receiver
Max. 1000 data per wavelength
Memory
LR6(AA) alkaline battery×4, 0.5 VA
Power supply
Dimensions and mass Approx. 85W ×192H (including 36 mm cover)×35D mm,
Approx. 300g (without batteries)
3662-20, 3663-20
Light-emitting element
Output connector
Fiber type
Output mode
Output wavelength
Power supply
Dimensions and mass
reference
5 max.)
55
SPECIFICATIONS
Laser diode
FC, SC (using optional connector adapter)
Single mode
Continuous wave (CW) or modulated light (270 Hz, 1 kHz, 2 kHz)
1310±20 nm (3663-20), 1550±20 nm (3662-20)
LR6(AA) alkaline battery×2, 0.6 VA
Approx. 76W ×159H (including 36 mm cover) ×35D mm,
Approx. 180g (without batteries)
3662-20, 3663-20
Light-emitting element
Output connector
Fiber type
Output mode
Output wavelength
Power supply
Dimensions and mass
3661-20
SPECIFICATIONS
Laser diode
FC, SC (using optional connector adapter)
STANDARD
Single mode
Continuous wave (CW) or modulated light (270 Hz, 1 kHz, 2 kHz)
3662-20 (1550mm)
1310±20 nm (3663-20), 1550±20 nm (3662-20)
3663-20 (1310mm)
LR6(AA) alkaline battery×2, 0.6 VA
Approx. 76W ×159H (including 36 mm cover) ×35D mm,
Approx. 180g (without batteries)
MAGNETIC FIELD HiTESTER
MAGNETIC FIELD SENSOR
3471 3472
3470
Test the magnetic field effect of home appliances against
human exposure (for IEC62233, EN50366, ICNIRP1998)
3471
3470 SPECIFICATIONS
Magnetic flux density (Band)
Exposure level
Measurement ranges
Display
Accuracy (with a 3471 or 3472)
Output
Interface
Power supply
Dimensions, mass
Accessories
10 Hz to 400 kHz / 10Hz to2 kHz / 2kHz to 400 kHz
General Public/Occupational
Magnetic flux density : 2.000µT/ 20.00µT/200.0µT/2.000mT
Exposure level : 20.00%/200.0%/2000%
Indicated axis (x,y,z,R) / Magnetic flux density / Exposure level (LCD Display)
±3.5%rdg. ±0.5%f.s.
200 mV/f.s.(for single axis of each range)
3-axis waveform output, resultant RMS output
USB ver.1.1
Four LR6 alkaline battery 1.5V (Battery life : Approx. 10 hours)
Or 9445-02 AC Adapter, 9445-03 AC Adapter
100 W × 150 H × 42 D mm, 870 g (batteries included)
CD (PC application software) , USB cable (1), LR6 alkaline battery (4), Carrying Case (1)
3470-01 Package:
• MAGNETIC FIELD HiTESTER
3470 × 1
• MAGNETIC FIELD SENSOR (3-axis, 100cm2 sensor)
3471 × 1
• AC Adapter
9445-02 or –03 × 1
3470-02 Package:
• MAGNETIC FIELD HiTESTER
3470 × 1
• MAGNETIC FIELD SENSOR (3-axis, 100cm2 sensor)
3471 × 1
• MAGNETIC FIELD SENSOR (3-axis, 3cm2 sensor)
3472 × 1
• AC Adapter
9445-02 or –03 × 1
• Extension Cable
9758 × 1
• Output Cable
9759 × 1
3470
3471
3472
3471 SPECIFICATIONS
OPTIONS
AC ADAPTER
AC ADAPTER (EU)
EXTENSION CABLE
OUTPUT CABLE
STANDARD
9445-02
9445-03
9758
9759
NOISE SEARCH TESTER
Identify noise in communication and power lines
Sensor crosssectional area
3472 SPECIFICATIONS
100 cm2
2 mT at a single axis (There
Rated magnetic
is a derating characteristics
flux density
dependent on frequency)
Frequency
10 Hz to 400 kHz
characteristics
Measured axes x, y, z
External dimensions Approx. φ122 × 295 (L) mm
Approx. 220 g
Weight
Sensor crosssectional area
Rated magnetic
flux density
Frequency
characteristics
Measured axes
External dimensions
Weight
3 cm2
2 mT at a single axis (There is a derating
characteristics dependent on frequency)
10 Hz to 400 kHz
x, y, z
Approx. φ27 × 165 (L) mm
Approx. 105 g
3144-20
3144-20 SPECIFICATIONS
Input unit configuration 9741dedicated input terminal, BNC input terminal (9741 takes priority)
500Hz to 30MHz, separated into 7ranges (-3 dB)
Frequency range
500Hz to 3kHz (1 kHz range) / 7.5kHz to 22.5kHz (15kHz range) / 35kHz
band
to 105kHz (70kHz range) / 125kHz to 375kHz (250kHz range) / 0.5MHz
to 1.5MHz (1MHz range) / 1.5MHz to 4.5kHz (3MHz range) / 10MHz to
30MHz (20MHz range) / (BNC input 50Ω termination)
RMS value conversion
Detection method
500Hz to 1 MHz or less±1.5dBV
Detection accuracy
1MHz to 30 MHz±2.0dBV
Display of measurement voltage level of each frequency range in levels on LCD (2.5dBV/
Monitoring function
SEG equivalent)
Measurement data and time saved to internal memory according to specified
Logging function
recording interval
1/2/5/10/20/30 seconds 1/2/5/10/20/30/60 minutes
Recording interval
Wave monitoring (Output of input signal coming from 9741 or BNC input)
Output function
Audible range monitoring (Output of detection signal envelope Earphone)
AA-size alkaline batteries (LR6) ×6, DC9 V 500mA
Power
Dimensions and mass 98W ×179H ×46D mm. 430g (excluding batteries)
OPTICAL POWER METER
Catering to a Broad Spectrum of Optical Pickup Measurement Applications
STANDARD
3144-20
9741
9741 SPECIFICATIONS
Sensor configuration
Frequency range
Conductor dia
Dimensios and mass
Electrostatic coupling non-contact voltage sensor
600Hz to 30MHz (-3dB )
φ20mm
62W ×158H ×40D mm, 260g
3664
STANDARD
3664 SPECIFICATIONS
Optical power measurement
Range setting
Accuracy
Wavelength sensitivity
compensation
Scaling
Display
Measurement display unit
Analog output
Output resistance
Power supply
Dimensions and weight
W, dBm
Auto (Manual setting available)
±0.7% (±5% in combination with the optional sensor)
Can be set for every 1nm.
Automatic compensation for the sensorʼs sensitivity
Max. 10 wavelengths preset (including initial value for a sensor)
Can be set for each wavelength.
4-1/2 digit, (19999 max.), Display resolution: 0.01dBm / 0.01dB
nW, µW, mW, dBm, dB
1V approx. when the sensor calibration point input
50Ω, Output connector φ3.5 mini jack
AA (LR6) ×4, AC adapter (9445-02), 1.6VA
85W × 160H × 35D mm, 270g (excluding batteries)
3664
9742 SPECIFICATIONS
Measurable wavelength
Measurable power
Max. rated measurable power
Optic receptacle element
Receptacle dimensions
Measurement accuracy
Wavelength initial setting
Dimensions & weight
320nm to 1100nm
-59dBm to +17dBm (at the calibration wavelength)
50mW (+17dBm) (at all direction irradiation)
Si photo-diode
9.6mm × 9.6mm
±4.3% (±5% in combination with 3664)
633nm, 635nm, 650nm, 780nm
9742: 18W × 180H × 20D mm, 100g
Cable length: 2m
9742
56
Options & Peripherals
METER RELAY
2103 2104
Advancing power saving and automation
Standard SPECIFICATIONS
Meter class
2103:±2.5% class, 2104: ±1.5% class
Deflecting range
Passing type, full scale
Lance shape, upper limit and lower limit pointer
Setting pointer
Setting accuracy
±1.5% of scale length
Minimum setting width
Within 3% of scale length
Relay power delay circuit Approx. 2 second
Relay output response
Approx. 0.5 second
Output contact capacity
5A (under condition of 250V AC, 30V DC,
resistance load)
Power supply
100 or 200V AC ±10%
●Electronic design assures high accuracy and reliability
●Ultra sensitive 1 mA, 10 mV DC movement
●Replaces relays in plug-in systems
●Includes a display lamp to illuminate movement at a glance
●Relay action delays circuit closure upon power on
●Both power circuitry and relay built-in
OPTIONS
(Special specifications)
●±1.5% class: for Model 2103
●Extended scale: double or triple extended scale
●Segmented scale: magnified scale for up to 40 % of the maximum scale value
●Double deflection meter: for example, zero-centered scale
●Relay response time: time constant 0.05 second fixed (DC) and variable types also
available
●Setting accuracy: Version with ±1.0 % type
●Delay time: Version with variable delay time after power on. 0.1 to 10 seconds: (for
instruments input DC), 2 to 12 seconds: (for instruments input AC)
●Output signal: Version with 1 V DC /f.s. output terminal
*not isolated from input circuit ground.
●Power supply: Version with 110, 120, 220, 230, 240 V AC ±10 %
2103
2104
■ Dimensions
■ Standard Scale Graduations
■ Standard Full-Scale Values
DC Ammeter
Std. Full-Scale
Value
DC Voltmeter
Meter
Std. Full-Scale
Sensitivity
Value
Spec.
Options & Peripherals
1 µA
10
20
50
100
200
500
1 mA*1
2
5
10
20
50
100
200
500
1 A
2
5
10
20
50mV
Full-Scale:
4-20mA
50mV
Meter
Sensitivity
Spec.
10 mV
15
30
50 *2
100
150
300
500
1V
1.5
3
5
10
15
30
50
100
150
300
100kΩ/V
100kΩ/V
100kΩ/V
100kΩ/V
100kΩ/V
100kΩ/V
100kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
Full-Scale:
1-5V
10kΩ/V
�When the full-scale value is larger than 20A, an
external shunt device is used with the 50-mV
instrument denoted by.*2
�When the full-scale value is larger than 300V, an
external multiplier is used with the 1-mA instrument
denoted by.*1
57
Rectifying AC Ammeter
Std. Full-Scale
Value
200 µA
500
1 mA*3
2
5
10
20
50
100
200
500
1A
2
3
5 *4
Rectifying AC Voltmeter
Meter
Std. Full-Scale
Sensitivity
Value
Spec.
50mV
50 mV
100
150
300
500
1V
1.5
3
5
10
15
30
50
100
150
300
Meter
Sensitivity
Spec.
10kΩ/V
10kΩ/V
10kΩ/V
10kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
1kΩ/V
�When the full-scale value is larger than 5A, an external
CT is used with the 5A instrument denoted by.*4
�When the full-scale value is larger than 300V, an
external multiplier is used with the 1-mA instrument
denoted by.*3
Full-Scale
Value
Graduations
1,10,100
50
1.5,15,150
30
2,20,200
40
2.5,25,250
50
3,30,300
30
5,50,500
50
6,60,600
30
7.5,75,750
37.5
Graduation Illustration
0
2
4
0
5
0
5
0
10
5
10
0
1
HL type
2
c contact used
OFF
ON
L setting
L type
H setting
ON
OFF
L setting
H type
OFF
3
2
0
20
2
2
0
a
15
ON
H setting
20
25
3
4
5
6
4
4
10
15
15
1
0
8
10
■ Contact operation
ON
6
6
7.5
Options & Peripherals
EXTERNAL
CT-2MR CT-5MRN
SHUNTS
HS-1 HS-2
CURRENT TRANSFORMER
W
HS-1
45
P
C
F
M5
M12
HS-2
EXTERNAL
MULTIPLIER
HS-2 SPECIFICATIONS
Model & rated current HS-2(500A), HS-2(750A), HS-2(1000A)
Accuracy (50/60 Hz)
JIS-Class0.5 (±0.5% at rated current)
Rating
50mV
Dimensions, mass
500A type:115(P),155(C),45(W),20(F)mm,740g
750A type:135(P),175(C),60(W),30(F)mm
1000A type:135(P),175(C),60(W),30(F)mm
Accessories
None
Note: The total resistance of the connection cord must be 0.1Ω or less.
HB-1
112
100.5
91
74
Used with a 1mA full scale meter
38
57
5
HB-1 SPECIFICATIONS
HB-1(500V), HB-1(750V)
Model & rated voltage
JIS-Class 0.5 (±0.5% at rated voltage)
Accuracy (50/60 Hz)
1mA
Rating
See figure, 75g
Dimensions, mass
None
Accessories
2-φ3.5
41
14
HS-1 SPECIFICATIONS
20
35
φ60
Secondary
terminal
M5
15
K
Secondary
terminal
M5×0.8
K
K
20
L
40
K
L
CT
φA
F
G
H
75
K
K
2
φA
D
φE
2.0
F
D
45
d
35
140
HS-1 SPECIFICATIONS
Model & rated current HS-1(30A), HS-1(50A), HS-1(75A), HS-1(100A),
HS-1(150A), HS-1(200A), HS-1(300A)
JIS-Class 0.5 (±0.5% at rated current)
Accuracy (50/60 Hz)
50 mV
Rating
30A type:20(E), 6(F),M4(d), M5(d) mm, 110g
Dimensions, mass
50A type:20(E), 8(F),M4(d), M8(d) mm, 150g
75A type:20(E), 8(F),M4(d), M8(d) mm, 155g
100A type:20(E),15(F),M5(d), M8(d) mm, 250g
150A type:20(E),15(F),M5(d), M8(d) mm, 250g
200A type:25(E),15(F),M5(d),M10(d) mm, 320g
300A type:25(E),15(F),M5(d),M10(d) mm, 330g
None
Accessories
15
E
φ4.5
85
120
26
Used with a 50mV full scale meter
70
80
100~200A:φA=φ20
250~400A:φA=φ30
5
20
35
CT-2MR
B
C
2-M6
8
45
52
CT-5MRN
CT-2MR:SPECIFICATIONS
Model & rated current CT-2MR(100A), CT-2MR(120A), CT-2MR(150A),
CT-2MR(200A), CT-2MR(250A), CT-2MR(300A)
JIS-Class1.0 (±1% of rated value)
Accuracy (50/60 Hz)
2VA
Rated load
5A (all models)
Secondary current
Conductor voltage rating 1150VAC
See figure
Dimensions
None
Accessories
CT-5MRN:SPECIFICATIONS
Model & rated current CT-5MRN(100A), CT-5MRN(120A), CT-5MRN(150A),
CT-5MRN(200A), CT-5MRN(250A), CT-5MRN(300A),
CT-5MRN(500A), CT-5MRN(600A)
Accuracy (50/60 Hz)
JIS-Class1.0 (±1% of rated value)
Rated load
5VA
Secondary current
5A (all models)
Conductor voltage rating 1150VAC
HB-1
Dimensions
100-200A:23(φA),70(B),85(C),65(D),60(φE),45(F),75(G),83(H) mm
250-300A:32(φA),70(B),85(C),76(D),70(φE),50(F),85(G),91(H) mm
500-600A:50(φA),80(B),100(C),89.5(D),85(φE),58(F),100.5(G),105(H)mm
Accessories
None
Wiring: Pass the wire through center of the C.T. When measuring under 100 A, use the
equation below to find the number of times that the wire is to be passed through. Number
of turns = (Primary current of C.T.)÷(Maximum value measured) However, in order to
make the number of turns a full number, select the primary current or full scale.
CT-2MR:SPECIFICATIONS
Model & rated current CT-2MR(100A),CT-2MR(120A),CT-2MR(150A
CT-2MR(200A),CT-2MR(250A),CT-2MR(300A
JIS-Class1.0(±1% of rated value)
Accuracy (50/60 Hz)
2VA
Rated load
5A(all models)
Secondary current
Conductor voltage rating 1150VAC
See figure
Dimensions
None
Accessories
Options & Peripherals
The HIOKI "Solution Factory"
58
Options & Peripherals
Note: * marked products are discontinued models.
Test Leads and Probes ...Included as accessories with main unit, or sold separately (optional products)
Options & Peripherals
59
TEST LEAD
3851-10
. . for 3251*, 3252*, 3253*
. . 3801-50, 3802-50, 3803
. . . . 3804, 3805, 7015
HIGH VOLTAGE PROBE
9014
. . for 3081*, 3205*, 3207*
. . . . 3208*, 3209*, 3212*,
. . . . . . . 3230*, 3250s
HIGH VOLTAGE PROBE
9017
. . for 3030*, 3012*, 3015*
. . . . . . 3021*, 3030-10
THERMISTER TEMPERATURE
PROBE
9021-01
. . for 3000*, 3007*, 3015*
. . . 3021*, 3030-10, 3100
TEST LEAD
9060
. . . . . for 3008, 3125*
TEST LEAD
9060-01
. . for 3108-01*, 3109-01*
. . . . . . . . . . . . . . 3008
TEST LEAD
9067
. . for 3127-10, 3128-10
. . . 3000*, 3021*, 3100*
. . . 3102*, 3104*, 3261*
. . . 3262*, 3264*, 3265*
OUTPUT CORD
9094
. . . . for 3412-50, 3283
. . . 3284, 3285, 3225*
. . . . . . . . 3404, 3422*
4-TERMINAL PROBE
9140
. . . . . for 3503, 3511-50
. . 3520*, 3521*, 3522-50
. . . . . . . . . . . . 3532-50
PINCHER PROBE
9143
. . . . . for 3503, 3511-50
. . 3520*, 3521*, 3522-50
. . . . . . . . . . . . 3532-50
TEST LEADS WITH FUSE
9153
. for 3021*, 3030*, 3127
. . . . . . . . . . . . . . 3128
CONNECTION CORD
9165
. for 3601*, 7075, 8850*
. . 8852*, 8852-01*, 8855
. . . LCR/Z HiTESTER
CONNECTION CORD
9166
. . . for 3601*, 7075, 8850 *
. . . . . 8852*, 8852-01*,
. . . LCR/Z HiTESTER
INPUT CORD
9168
. . . . . for 7010*, 7011
TEST LEAD
9170
. . for 3156, 3155, 3200*
. . . 3210*, 3215*, 3216*
. . . 3222*, 3223*, 3230*
. . . 3231*, 3233*, 3234*
. . . 3236*, 3256*, 3257*
. . . . . . . . . . . . . . 7011
INPUT CORD
9177
. . for 8815*, 8816*, 8830*
. . . . . . . 8831*, 8832*
. . . . . . . . . . . . . 8833*
. . . . . . . . . . . . . 8821*
. . . . . . . . . . . . . . 9555
VOLTAGE CORD
9178
. . . . . . . . . . . for 3165
VOLTAGE CORD
9179
. . . for 3167, 3192*, 3195*
TEST LEAD
9185
. . . . . . . . . . for 3255*
INPUT CORD
9186
. . for 8852*, 8852-01*
VOLTAGE APPLY PROBE
9190
. . . . . . . . for 3155-01*
ENCLOSURE PROBE
9195
. . . . . . . . for 3155-01*
APPLY UNIT
9196
. . . . . . . . for 3155-01*
CONNECTION CORD
9197
. . for 8806*, 8807, 8808
. . . . 8826, 8835, 8841
. . 8842, 8855, 8860, 8861
CONNECTION CORD
9198
. . for 8806*, 8807, 8808
. . . . 8826, 8835, 8841
. . 8842, 8855, 8860, 8861
CONVERSION ADAPTOR
9199
. . for 8806*, 8807, 8808
. . . . 8826, 8835, 8841
. . 8842, 8855, 8860, 8861
TEST LEAD
9207
. . . . . . . . . for 3030-10
TEST LEAD
9207-10
. . . . . . . . . . . for 3281,
3282, 3284, 3285
3256-50/-51, 3257-50/-51
TEST LEADS
9208
. . for 3280*, 3280-01*
. . . . . . . . . . . . 3280-10
. . 3280-20, 3287, 3288
TEST LEADS HOLDER
9209
. . for 3280*, 3280-01*
. . . . . . . . . . . . 3280-10
. . 3280-20, 3287, 3288
MEASURING CABLE
9215
. . . . . . . . . . . for 3151
CONNECTION CORD
9217
. . for 8806*, 8807, 8808
. . . . 8826, 8835, 8841
. . 8842, 8855, 8860, 8861
CONNECTION CABLE
9219
. . for 9695-02, 9695-03
CONNECTION CORD
9257
. . for 8205-10, 8206-10
. . . . . . 8220*, 3454-11
. . . . . . . 3454-10, 3453
. . . . . . 3118-11, 3118-12
TEST FIXTURE
9261
. . . . . for 3503, 3511-50
. . 3520*, 3521*, 3522-50
. . 3530*, 3531*, 3532-50
TEST FIXTURE
9262
. . . . . for 3503, 3511-50
. . 3520*, 3521*, 3522-50
. . 3530*, 3531*, 3532-50
THERMISTER
TEMPERATURE PROBE
9263
. . . 3503, 3511-50, 3520*
. . 3521*, 3522-50, 3530*
. . . . . . 3531*, 3532-50
WIRING ADAPTER
9264-01
. . . . . . . . . . . for 3196
WIRING ADAPTER
9264-02
. . . . . . . . . . . for 3196
MEASUREMENT CABLE
9265
. . . . . . . . . . . for 3143
DC BIAS VOLTAGE UNIT
9268
. . . . . for 3503, 3511-50
. . . . . 3522-50, 3532-50
DC BIAS CURRENT UNIT
9269
. . . . . for 3503, 3511-50
. . . . . 3522-50, 3532-50
Note: * marked products are discontinued models.
TEST PROBE
9289
. . . for 3118-11, 3118-12
. . . . 3154, 3453, 3454s
TEST PROBE
9292
. . . for 3451-11, 3451-12
. . . . . . 3451-13, 3451-14
. . . . . . 3451-15, 3452-11
. . . . . . . . . . . . . 3452-12
PIN TYPE EARTH PROBE
9293
. . . for 3451-11, 3451-12
. . . . . . 3451-13, 3451-14
. . . . . . 3451-15, 3452-11
. . . . . . . . . . . . . 3452-12
TEST PROBE
9294
. . . .for 3117s*, 3118-11
. . . 3118-12, 3154, 3453
CURRENT PROBE
9296
. . . . . for 3157, 3157-01
CURRENT APPLY PROBE
9297
. . . . . for 3157, 3157-01
SWITCHED PROBE
9299
. . . . . . . . . . . . for 3154
CONNECTION CABLE
9300
. . . . . . . . . . . . for 3541
CONNECTION CORD
9326
. . . . for 8205*, 8205-10
CONNECTION CABLE
9437
. . . . . for 8845*/8846*
VOLTAGE CORD
9438
. . . . . . . . . . . for 3166*
VOLTAGE CORD
9438-02
. . . . . . . . . . . . for 3196
VOLTAGE CORD
9438-03
. . . . . . . . . . . . for 3169
9438-05
. . . . . . . . . . . . for 3197
CLIP TYPE LEAD
9452
. . .for 3227*, 3239, 3540
. . . . .3541, 3555, 3560
FOUR TERMINAL LEAD
9453
. . .for 3227*, 3239, 3540
. . . . .3541, 3555, 3560
ZERO ADJUSTMENT BOARD
9454
. . for 3155-01*, 3227*,
. . . . 3239, 3540, 3541,
. . . . .3554, 3555, 3560
PIN TYPE LEAD
9455
. . .for 3227*, 3239, 3540
. . . . .3541, 3555, 3560
CLIP TYPE LEAD WITH
TEMPERATURE SENSOR
9460
for 3540, 3550*, 3551*
. . . . . . . . . . . . . . .3554
PIN TYPE LEAD
9461
. . . for 3155-01*, 3227*
. . . . .3239, 3540, 3541
. . . . . . . . . .3555, 3560
PIN TYPE LEAD
9465
. . for 3239, 3540, 3541
. . .3550*, 3551*, 3555
. . . . . . . . . . . . . . .3560
PIN TYPE LEAD
9465-10
. . for 3239, 3540, 3541
. . 3550*, 3551*, 3554, 3555
. . . . . . . . . . . . . . .3560
REMOTE CONTROL SWITCH
9466
. . .for 3551*, 3554, 3560
LARGE CLIP TYPE LEAD
9467
. . .for 3227*, 3239, 3540
. . .3541, 3550*, 3551*
. . . . . . . . . .3554, 3560
INPUT CORD
9574
. . .for 8840*/45*/46*,8853*,8851*
H.V.TEST LEAD
9615
. . for 3153, 3158, 3159
. . . . . . . . . .3173, 3930
CLIP ON BASE
9617
. . for 3501, 3801, 3802
. . . . . . . . . .3804, 3805
CLIP-TYPE LEAD
9618
. . for 3501, 3801, 3802
. . . . . . . . . .3804, 3805
VOLTAGE CORD
9635
. . . . for 3286*, 3286-20
VOLTAGE CORD
9635-01
. . . . . . . . . . for 3286-20
CONNECTION CABLE
9639
. . . . . . . for 3637, 3645
CONNECTION CABLE
9641
. . for 8420-51, 8421-51, 8422-51
10:1PROBE
9665
. . . . . . . . . . . . for 8855
100:1PROBE
9666
. . . . . . . . . . . . for 8855
SMD TEST FIXTURE
9677
. . . . .for 3503, 3511-50,
. 3522-50, 3532-50, 3535
SMD TEST FIXTURE
9699
. . . . .for 3503, 3511-50,
. 3522-50, 3532-50, 3535
PIN TYPE LEAD
9770
. . for 3239, 3540,3541,
3555, 3560, 3561
PIN TYPE LEAD
9771
. . for 3239, 3540,3541,
3555, 3560, 3561
PIN TYPE LEAD
9772
. . for 3239, 3540, 3541
. .3550*, 3551*, 3554, 3555
. . . . . . . . . . . . . . .3560
ALLIGATOR CLIPs
. . . . . . .(used with Test
Lead, insert), for 9170,
or similar devices
CLIP TYPE LEAD
9287-10
. . . for 3155-01*, 3226*
. . . .3227*, 3239, 3540
. . . . .3541, 3555, 3560
Options & Peripherals
BREAKER PIN
9288
. . . for 3118-11, 3118-12,
. . . . . 3451-11, 3451-12,
. . . . . 3451-13, 3451-14,
. . . . . 3451-15, 3452-11,
. . . . . 3452-12, 3452-13,
. . . . . . . . . 3453, 3454s
60
Options & Peripherals
ELECTRODE and SHIELDING BOX
(for SM-8200 Series, DSM-8104, DSM8542 options)
ELECTRODE FOR CHIP CAPACITOR SME-8360
The electrodes on this fixture are for
insulation resistance measurement of
chip capacitors, and the fixture can be
adjusted anywhere from 0 to 11 mm to
measure a wide range of chip capacitors.
When the fixture is connected with the
interlock connection cable, measurement
voltage is disabled when the lid is open.
Plugs need to be modified when used in
combination with the SM-8200 series.
External Dimensions: Approx. 200 (W) × 52 (H) × 150 (D) mm, Lead Length: Approx. 85 cm, connects with special Hioki plug.
PLATE SAMPLE ELECTRODE SME-8310
The electrodes on this fixture are for
measuring the characteristic resistivity
of flat samples up to 100 mm square and
8 mm thick: the main electrode is 50 mm
in diameter, and the guard electrode has
70 mm ID and 80 mm OD. When the fixture
is connected with the interlock connection
cable, measurement voltage is disabled
when the lid is open. A side panel switch
easily selects between volume and surface
resistivity.
External Dimensions: Approx. 215 (W) × 78 (H) × 165 (D) mm, Lead Length: Approx. 75 cm, connects with special Hioki plug.
ELECTRODE FOR FLAT SAMPLE SME-8311
The electrodes on this fixture are for measuring
characteristic resistivity of flat samples up to 40
× 100 mm and 8 mm thick. The main electrode is
19.6 mm in diameter, and the guard electrode has
24.1 mm ID and 28.8 mm OD.
A side panel switch easily selects between
volume and surface resistivity.
External Dimensions: Approx. 215 (W) × 78 (H) × 165 (D) mm, Lead Length: Approx. 75 cm, connects with special Hioki plug.
WEIGHT ELECTRODE SME-8320
These electrodes for flat samples are
used in combination with the SME-8350
Shielded Enclosure. Easily measures
surface and volume resistivity of even
coarse surfaces such as carpet. The main
electrode is 50 mm in diameter, and the
guard electrode has 70 mm ID and 80 mm
OD. The jig for concentric electrodes is
included.
Accessories: Two banana-plug leads
Options & Peripherals
Note: Illustrated with the SM-8350
shielded enclosure.
SME-8301
Measures surface resistivity simply by pressing the
probe tips on the sample.
Primarily intended for use with the SM-8213, to
measure surface resistivity of electrostatic-dischargerelated samples. Measures up to 1010Ω.
External Dimensions: Approx. 60 OD × 50 mm long,
Lead Length: Approx. 1 m, connects with special Hioki plug.
LIQUID SAMPLE ELECTRODE SME-8330
The electrodes for fluid samples are equipped with
a guard. Capacity is 25 mL, capacitance between
main and counter electrodes is approximately 45 pF,
electrode constant is about 500 cm inter-electrode
spacing is 1 mm, electrode OD is 36 mm and height
is about 140 mm. Measures up to 1019 Ωcm (@1,000 V)
when combined with the SM-8220.
Accessories: Connection cable, one each red and black,
approx. 60 cm long
CONTINUOUS LIQUID SAMPLE ELCTRODE
SME-8335
The insulation resistance of fluids such as machine oil
or irrigation fluid can be measured in the flowing state
through 1⁄4-inch NPT joints. The cell can be mounted
with U-bolts using the supplied metal accessory.
Container volume is about 30 mL, and electrode
constant is about 75 cm.
External Dimensions: Approx. 58 OD × 80 mm height
Lead Length: Approx. 5 m, with special Hioki plug.
SHIELDING BOX SME-8350
This enclosure provides electromagnetic
shielding when measuring samples with high
insulation resistance or reactance.
When used with the SME-8320 Weight
Electrodes, it provides the counter or guard
electrode. When measuring electronic
components such as capacitors and
transformers, it shields against external
noise and leakage current to provide stable
measurements.
External Dimensions: Approx. 250 (W) × 100 (H) × 200 (D) mm
Lead Length: Approx. 80 cm, with special Hioki plug.
STANDARD RESISTOR SR-2
This resistance box is designed for
calibrating Hioki’s series of ultra insulation
testers. The construction ensures secure
connection between the box and the tester.
Maximum operating voltage is 1,000 V DC,
and it provides 24 resistance values between
10 MΩ and 10,000 MΩ.
External Dimensions: Approx. 270 (W) × 90 (H) × 195 (D) mm
ELECTRODE FOR SURFACE RESISTANCE SME-8302
This two-electrode probe is suitable for surface
resistivity measurement of curved surfaces
such as molded resin and rubber products,
and for small samples. Measures surface
resistivity simply by pressing the probe tips on
the sample. Electrode spacing is 10 mm, and
measures up to 1010Ω. (4 mm inter-electrode
spacing)
External Dimensions: Approx. 40 mm OD × 115 mm long, Lead Length: Approx. 1 m, connects with special Hioki plug.
61
SURFACE RESISTANCE MEASUREMENT ELECTRODE
RECORDING PAPERs ...Sold separately (optional products)
Recording
Paper
9233
9223
9232
9232
9237
9237
Model
LEAK CURRENT HiTESTER 3155-01*
CLAMP ON POWER HiTESTER 3165*
POWER HiTESTER 3193
MOTOR/HARMONIC HiTESTER 3194
POWER QUALITY ANALYZER 3196
RESISTANCE HiTESTER 3541
MICRO HiCORDER 8205-10
9235
9236-01
MICRO HiCORDER 8206-10
9235
9236-01
MEMORY HiLOGGER 8420-01*
MEMORY HiLOGGER 8420-51
MEMORY HiLOGGER 8421-01*
MEMORY HiLOGGER 8421-51
MEMORY HiLOGGER 8422-01*
MEMORY HiLOGGER 8422-51
POWER HiCORDER 8715-01
MEMORY HiCORDER 8807-01
9234
9234
9234
9234
9234
9234
9234
9234
Paper Size
58 mm × 10 m, 10 rolls
58 mm × 10 m, 10 rolls
74 mm × 10 m, 10 rolls
74 mm × 10 m, 10 rolls
80 mm × 25 m, 4 rolls
80 mm × 25 m, 4 rolls
60 mm × 15 m, 10 rolls
60 mm × 15 m, climateresistant, 10 rolls
60 mm × 15 m, 10 rolls
60 mm × 15 m, climateresistant, 10 rolls
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
Recording
Paper
9234
9234
9234
Model
MEMORY HiCORDER 8807-51
MEMORY HiCORDER 8808-01
MEMORY HiCORDER 8808-51
MEMORY HiCORDER 8826
9229
9229-01
MEMORY HiCORDER 8835-01
MEMORY HiCORDER 8841
MEMORY HiCORDER 8842
MEMORY HiCORDER 8852, 8852-01*
MEMORY HiCORDER 8855
MEMORY HiCORDER 8860, 8861
PRINTER UNIT 8992
PRINTER UNIT 8994
DIGITAL PRINTER 9203
PRINTER 9442
PRINTER UNIT 9604
PRINTER 9670
9221
9231
9231
9221
9231
9231
9234
9231
9233
1196
9232
9237
Paper Size
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
112 mm × 18 m, 10 rolls
264 mm × 30 m, 6 rolls
264 mm × 30 m,
perforated, 6 rolls
110 mm × 30 m, 10 rolls
216 mm × 30 m, 6 rolls
216 mm × 30 m, 6 rolls
110 mm × 30 m, 10 rolls
216 mm × 30 m, 6 rolls
216 mm × 30 m, 6 rolls
112 mm × 18 m, 10 rolls
216 mm × 30 m, 6 rolls
58 mm × 10 m, 10 rolls
112 mm × 25 m, 10 rolls
74 mm × 10 m, 10 rolls
80 mm × 25 m, 4 rolls
Temperature probes or sensors ...Included as accessories with main unit, or sold separately (optional products)
Model
Type/Note
THERMISTER TEMPERATURE PROBE
-50 to 200˚C
9021-01
Sheath type, up to 750°C
non-waterproof
Surface type, up to 400°C
non-waterproof
Sheath type, up to 750°C
non-waterproof
Sheath type, up to 750°C
non-waterproof
reference contact compensation
TEMPERATURE PROBE 9180
TEMPERATURE PROBE 9181
TEMPERATURE PROBE 9182
TEMPERATURE PROBE 9183
RJ SENSOR 9184
-25 to 80˚C
TEMPERATURE PROBE 9188
TEMPERATURE PROBE 9451
THERMISTER TEMPERATURE PROBE 9462
TEMPERATURE HUMIDITY SENSOR 9463
TEMPERATURE HUMIDITY SENSOR 9464
TEMPERATURE PROBE 9472
TEMPERATURE PROBE 9472-50
TEMPERATURE PROBE 9473
TEMPERATURE PROBE 9473-50
TEMPERATURE PROBE 9474
TEMPERATURE PROBE 9475
included with the 3227
included with the 3540
-50 to 150˚C
fixed type
extension type, (2.7m)
Sheath type, up to 300°C
waterproof structure
Sheath type, up to 300°C
waterproof structure
Sheath type, up to 800°C
waterproof structure
Sheath type, up to 800°C
waterproof structure
Sheath type, up to 300°C
waterproof structure
Sheath type, up to 500°C
waterproof structure
Compatible Instrument
Model
Type/Note
3030-10, 3127-10, 3128-10
TEMPERATURE PROBE 9476
3412-50, 3441, 3442
TEMPERATURE PROBE 9476-50
3412-50, 3441, 3442
TEMPERATURE PROBE 9478
3412-50, 3441, 3442
TEMPERATURE PROBE 9479
3412-50, 3441, 3442
7011
3227*
3540
3281, 3282
3625
3625
3441, 3442
3446-01
3441, 3442
3446-01
3441, 3442
3441, 3442
φ
φ
HUMIDITY SENSOR 9680
HUMIDITY SENSOR 9680-01
HUMIDITY SENSOR 9680-02
TEMPERATURE SENSOR
9631-01
TEMPERATURE SENSOR
9631-11
TEMPERATURE SENSOR
9631-21
TEMPERATURE SENSOR
9631-02
TEMPERATURE SENSOR
9631-03
TEMPERATURE SENSOR
9631-04
TEMPERATURE SENSOR
9631-14
TEMPERATURE SENSOR
9631-24
TEMPERATURE SENSOR
9631-05
3441, 3442
1 m length
10 m length
3641-20
3641-20
3641-20
1 m length
3632 / 3633 / 3641-20
5 m length
3632 / 3633 / 3641-20
10 m length
3632 / 3633 / 3641-20
1 m length
3632 / 3633 / 3641-20
1 m length
3632 / 3633 / 3641-20
1 m length
3632 / 3633 / 3641-20
5 m length
3632 / 3633 / 3641-20
10 m length
3632 / 3633 / 3641-20
30 mm length
3632 / 3633 / 3641-20
5 m length
9472-50, 9473-50 (K)
3447-01(Pt-100)
100
100
φ5.0
1000
9476-50 (K)
9479 (Pt-100)
φ2.3
150
Hand switch
25
90
100
1000
100
157
φ
9476
9631-01
9631-11
9631-21
φ5.0
φ20
9474, 9475
9680-50
9680-51/52
1000
9631-02
9631-03
9631-04
9631-14
9631-24
1000
Options & Peripherals
9021-01
3447-01(Pt-100)
φ2.3
150 (9472-50)
300 (9473-50)
φ
φ
3446-01
9478 (Pt-100)
φ2.3 (9472-50)/φ4.8(9473-50)
9472, 9473
Compatible Instrument
Surface type, up to 500°C
non-waterproof
Surface type, up to 500°C
non-waterproof
Sheath type, up to 300°C
Waterproof structure
Sheath type, up to 300°C
Waterproof structure
9631-05
62
Options & Peripherals
Note: * marked products are discontinued models.
All Accessories
Options & Peripherals
63
RECORDING PAPER 1195 . . . . . for 3192 (10rolls)*
RECORDING PAPER 1196
. . . . . . . . . . . . . for 3154, 3332-02, 3511, 3196 (10rolls)
TEST LEAD 3851-10
. . . . . . . . . . . . . . . for 3801, 3802, 3803, 3804, 3805
RS-232C PACKAGE 3852 . . . . . . . . for 3801, 3802
CARRYING CASE 3853 . . . . . for 3803, 3804, 3805
RS-232C PACKAGE 3854 . . . for 3803, 3804, 3805
RS-232C PACKAGE 3856-01
. . . . . . . . . . . . . . . . . . . . . . for 3801-50, 3800-50, 7016
USB PACKAGE 3856-02
. . . . . . . . . . . . . . . . . . . . . . for 3801-50, 3802-50, 7016
INTERFACE PACK 3909 . . . . . for 3443, 3444, 3445
CLAMP ON PROBE 9010 . . . . . . . . for 8200*, 3255
CLAMP ON PROBE 9010-10 . . . . . for 8714*, 8715
HIGH VOLTAGE PROBE 9014
. . . . for 3081*, 3205*, 3207*, 3208*, 3209*, 3212*, 3230*, 3250S
HIGH VOLTAGE PROBE 9017
. . . . . . . . . . . . . for 3000*, 3012*, 3015*, 3021*, 3030
CLAMP ON PROBE 9018
. . . . . . . . . . . . . . . . for 8205, 8206, 8805*, 8807, 8808
CLAMP ON PROBE 9018-10 . . . . . for 8714*, 8715
THERMISTER TEMPERATURE PROBE 9021-01
. . for 3000*, 3007*, 3015*, 3021*, 3030, -12, 3100*, 3127-11
METAL CONTACT TIP 9032 . . . . 3402*, 3403, 3404
RUBBER CONTACT TIP 9033
. . . . . . . . . . . . . . . . . . . . . . . . . . for 3402*, 3403, 3404
AC ADAPTER 9035
. for 3108*, 31*, 32*, 61*, 62*, 3220*, 05*, 09*, 3402~04, 22 (6V)*
AC ADAPTER 9036
. . . . . . . . for 3110*, 3204*, 9005*, 9006*, 3411 (9V)*
AC ADAPTER 9039 . . . . . . . . . . . . . . for 3501 (12V )
EARTH NETS 9050 . . . . . . . for 3124*, 3150*, 3151
TEST LEAD 9060 . . . . . . . . . . . . . . . for 3008, 3125*
TEST LEAD 9060-01 . . . . . . . . . . . . for 3108*, 3109*
TEST LEAD 9067
. . . . . . . . . . . . . . . . for 3261*, 3262*, 3127-10, 3128-10
AC ADAPTER 9070 . . . . . . . . . . . . . for 3118, 3119*
RECORDING PAPER 9073
. . . . . . . . . . . . . . . . . for 8201*, 8202*, 8204 (10rolls)*
RECORDING PAPER 9074
. . . . . . . . . . . . . . . . . . . . . . . . for 8203 (1ch) (10rolls)*
EXTERNAL SHUNT 9081 . . . . . . . . for 3245 (10A)*
CARRYING CASE 9083
. . . . . . . . . . . . . . . . . . for 3108*, 3109*, 3131*, 3132*
CARRYING CASE 9084
. . . . . . . . . . . . . . . . . . for 3180*, 3222*, 3223*, 3235*
CARRYING CASE 9088 . . . . . . . . for 3030*, 3021*
OUTPUT CORD 9094
. . . . for 3154, 3225*, 3403, 04, 3412-50, 3422*, 3283, 84, 85
CLAMP ON PROBE 9132 . . . . . . . . . . for AC1000A
CLAMP ON PROBE 9132-10 . . . . . for 8714*, 8715
RECORDING PAPER 9135 . . . . . . for 3215 (5rolls)*
4-TERMINAL PROBE 9140
. . . . . . . . . . . . . . . for 3511, 3520*, 3521*, 3522, 3532
PINCHER PROBE 9143
. . . . . . . . . for 3511, 3520*, 3521*, 3530*, 3522, 3532
CARRYING CASE 9144 . . . . . . . . for 3030*, 3021*
CARRYING CASE 9148
. . . . . . . . . . . . . . . . . . . for 3128, 3261*, 3262*, 3263*
GP-IB CONNECTOR CABLE 9151-02
. . . . . . . . . . . . . . . . . . . . for 3511, 3330-02*, 3332 (2m)
GP-IB CONNECTOR CABLE 9151-04
. . . . . . . . . . . . . . . . . . . . for 3511, 3330-02*, 3332 (4m)
TEST LEADS WITH FUSE 9153
. . . . . . . . . . . . . . . . . . for 3030, 3127*, 3128*, 3127-11
CONNECTION CORD 9165
. . . . . . . . . for 3511, 3601*, 7075, 7075-01(BNC-BNC)
CONNECTION CORD 9166
. . . . . . . . . for 3511, 3601*, 7075, 7075-01 (BNC-Clip)
INPUT CORD 9168 . . . . . . . . . . . . . for 7010*, 7011
TEST LEAD 9170 . . . . . . . . . . . for 3156, 3237s, 7011
INPUT CORD 9177 . . . for 8904*, 8906*, 8932*, 9555
VOLTAGE CORD 9178 . . . . . . . . . . . . . . . for 3165*
VOLTAGE CORD 9179 . . . . . . . . . . . . . . . for 3195*
SHEATH TYPE TEMPERATURE PROBE 9180
. . . . . . . . . . . . . . . . . . . . . for 3412-50, 3441/42 (200°C)
SURFACE TEMPERATURE PROBE 9181
. . . . . . . . . . . . . . . . . . . . . for 3412-50, 3441/42 (400°C)
SHEATH TYPE TEMPERATURE PROBE 9182
. . . . . . . . . . . . . . . . . . . . for 3412-50, 3441/42 (1000°C)
SHEATH TYPE TEMPERATURE PROBE 9183
. . . . . . . . . . . . . . . . . . . . . for 3412-50, 3441/42 (800°C)
TEMPERATURE PROBE 9184
. . . . . . . . . . . . . . . . . . . . for 7010*, 7011 (-25°C~80°C)
TEST LEAD 9185 . . . . . . . . . . . . . . . . for 3154, 3255
INPUT CORD 9186 . . . . . . . . . . . . . for 8851(10:1)*
TEMPERATURE PROBE 9188 . . . . . . . . . for 3227*
VOLTAGE APPLY PROBE 9190 . . . . . . . . for 3155*
ENCLOSURE PROBE 9195 . . . . . . . . . . . for 3155*
APPLY UNIT 9196 . . . . . . . . . . . . . . . . . . . for 3155*
CONNECTION CORD 9197
. . . . . for 8807, 8808, 8826, 8835-01, 8841, 8842, 8855, 8860
CONNECTION CORD 9198
. . . . . for 8807, 8808, 8826, 8835-01, 8841, 8842, 8855, 8860
CONVERSION ADAPTER 9199
. . . . . for 8807, 8808, 8826, 8835-01, 8841, 8842, 8855, 8860
DIGITAL PRINTER 9203
. . . . . . . . . . . . . . . . . . . . . for 3227*, 3540, 3550, 3560
TEST LEAD 9207
. . . . . . . . . . . for 3030-10, 3030-12, 3282-01, 3284, 3285
TEST LEAD 9207-10
. . . . . . . . . for 3281, 82, 84, 85, 3256-50/-51, 3257-50/-51
TEST LEADS 9208
. . . . . . . . . . . . . . . . . . for 3287, 3280, -01, -10, -11, 3288
TEST LEADS HOLDER 9209
. . . . . . . . . . . . . . . . . . for 3287, 3280, -01, -10, -11, 3288
REFLECTIVE TAPE 9211 . . . . for 3402*, 3403, 3404
PERIPHERAL RING 9212 . . . for 3402*, 3403, 3404
CONTACT ADAPTER 9213 . . . . . . . . for 3403, 3404
AUXILIARY EARTHING ROD 9214 . . . . . . . for 3151
MEASURING CABLE 9215 . . . . . . . . . . . . . for 3151
CABLE WINDER 9216 . . . . . . . . . . . . . . . . . for 3151
CONNECTION CORD 9217
. . . . . . . . . for 8807, 08, 8826, 8841, 8842, 8855, 8860
CONNECTION CABLE 9219
. . . . . . . . . . . . . . . . . . for 3169, 3196, 9695-02, 9695-03
RECORDING PAPER 9221 . . . . . . . . . . . . . . . . . .
. . . . for 8801*, 8802*, 8835-01 (110mm × 30m 10rolls)
RECORDING PAPER 9222
. . . . . . . . . . . . . . . . . . . . for 3224-02*, 3225-02*, 3235*
. . . . . . . . . . . . . . . . . . . . . . 9200 (38mm × 8.5m 5rolls)
RECORDING PAPER 9223
. . . . . . . . . . . . for 3165*, 3191 (80mm × 30m 5rolls)*
RECORDING PAPER 9224
. . . . . . . . . . . . . . . . . for 8820 (216mm × 50m 6rolls)*
RECORDING PAPER 9226
. . . . . . . . . . . . . . . . . for 8601 (24mm × 15m 10rolls)*
RECORDING PAPER 9227
. . . . . . . . . . . . . . . . . . . for 3234 (38mm × 3m 5rolls)*
RECORDING PAPER 9228
. . . . . . . . . . . . . . . . . for 8850 (114mm × 30m 10rolls)*
RECORDING PAPER 9229
. . . . . . . . . . . . . . . . . for 8825 (264mm × 30m 6rolls)*
RECORDING PAPER(PERFORATED) 9229-01
. . . . . . . . . . . . . . . . . . for 8826 (264mm × 30m 6rolls)
RECORDING PAPER 9231
. . . for 8840*, 8841, 8842 (216mm × 30m 6rolls), 8855, 8860
RECORDING PAPER 9232
. . . . . . . . . . . . . . . . . . . . for 8804*, 8205, 8206, 8806*
. . . . . . . . . . . . . . . . . . . . . . 3193 (74mm × 10m 10rolls)
RECORDING PAPER 9233 . . . . . . for 9203, 9203-01
RECORDING PAPER 9234 . . . for 8807, 8808, 8420
RECORDING PAPER 9235 . . . . . . . . for 8205, 8206
RECORDING PAPER 9236-01 . . . . . for 8205, 8206
RECORDING PAPER 9237 . . . . . . . for 9670 (3196)
CARRYING CASE 9245 . . . . . . . . . . . . . for 3286-20
CARRYING CASE 9246 . . . . . . . . . . for 3664, 9742
CONNECTION CORD 9257 . . for 8205, 8206, 8220*
TEST FIXTURE 9261 . . . . . . . . . . . . . . . . . . . for LCR
TEST FIXTURE 9262
. . . . . . . . . for 3502*, 3511, 3520*, 3522, 3531*, 3532
THERMISTER TEMPERATURE PROBE 9263
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3511, 3522, 3532
WIRING ADAPTER 9264-01 . . . . . . for 3196, (3P3Ø)
WIRING ADAPTER 9264-02 . . . . . . for 3196, (3P4Ø)
MEASUREMENT CABLE 9265 . . . . . . . . . . for 3143
SAFETY TEST DATA MANAGEMENT SOFTWARE 9267
. . . . . . . . . . . . . . . . . . . . for 3153, 3156/57/58/59, 3332
DC BIAS VOLTAGE UNIT 9268
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3511, 3522, 3532
DC BIAS CURRENT UNIT 9269
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3511, 3522, 3532
CLAMP ON SENSOR 9270
. . . . . . . . . . . . . for 3191*, 3165*, 3192*, 3167* (20A)
CLAMP ON SENSOR 9271
. . . . . . . . . . . . for 3191*, 3165*, 3192*, 3167* (200A)
CLAMP ON SENSOR 9272
. . . . . . . . . . for 3191*, 3165*, 3192*, 3167* (20/200A)
CLAMP ON AC/DC SENSOR 9274
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for AC/DC20A
CLAMP ON AC/DC SENSOR 9276
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for AC/DC150A
UNIVERSAL CLAMP ON CT 9277
. . . . . . . . . . . . . . for 3192*, 3193, 3167* (AC/DC20A)
UNIVERSAL CLAMP ON CT 9278
. . . . . . . . . . . . . for 3192*, 3193, 3167* (AC/DC200A)
UNIVERSAL CLAMP ON CT 9279
. . . . . . . . . . . . . for 3192*, 3193, 3167* (AC/DC 500A)
CLIP TYPE LEAD 9287-10 . . . . for 3540, 3541, 3560
BREAKER PIN 9288 . . . . . . . . . . for 3451, 52, 53, 54
TEST PROBE 9289 . . . . . . . . . . . . . for 3154, 3454-51
CLAMP ON ADAPTER 9290-10
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 1000A CT 10 : 1
CLAMP ON SENSOR 9291 . . . . . . . . . . . . for 3166*
TEST PROBE 9292 . . . . . . . . . . . . . . . for 3451, 3452
PIN TYPE EARTH PROBE 9293 . . . . for 3451, 3452
TEST PROBE 9294 . . . . . . . . . . . . . . . for 3154, 3453
CURRENT PROBE 9296 . . . . . . . . for 3157, 3157-01
CURRENT APPLY PROBE 9297
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3157, 3157-01
SWITCHED PROBE 9299 . . . . . . . . . . . . . . for 3154
CONNECTION CABLE 9300 . . . . . . . . . . . for 3541
PT 9303
. . . . . . . for 8815*, 25*, 30*, 32*, 51* (PT 40:1,20:1 )
TRIGGER CORD 9305
. . . . . . . . . . . .for 8801*, 8802*, 8803*, 8820*, 8835-01
LOGIC PROBE 9315 . . . . . . . . . . . . . . . . . for 8852*
CONVERSION CABLE 9318 . . . . . . . . . . . . for 8940
CONVERSION CABLE 9319 . . . . . . . . . . . . for 8940
LOGIC PROBE 9320 . . . . . . . . . . . . . . for 8800series
LOGIC PROBE 9320-01 . . . . . . . . . . . for 8807, 8808
LOGIC PROBE 9321 . . . . . . . . . . . . . . for 8800series
LOGIC PROBE 9321-01 . . . . . . . . . . . for 8807, 8808
DIFFERENTIAL PROBE 9322 . . . . . . . for 8800series
CONVERSION CABLE 9323 . . . . . . . for 9320, 9321
POWER CORD 9324 . . . . . . . . . . . . . . . . . . for 9322
POWER CORD 9325 . . . . . . . . . . . . . for 8940, 9322
CONNECTION CORD 9326 . . . . . . . for 8205, 8206
LOGIC PROBE 9327 . . . . . . . . . . . . . . for 8800series
POWER CORD 9328 . . . . . . . . . . . . . . . . . . for 8855
TERMINAL UNIT 9329
. . . . . . . . . . . . . . . . . . . . . for 8420-51, 8421-51, 8422-51
WAVE PROCESSOR 9330-01 . . . . . . . . . . . for 8835
WAVE PROCESSOR 9331-01 . . . . . . . . . . for 8806*
WAVE COMMUNICATOR 9332 . . . . . . . . . for 8808
LAN COMMUNICATOR 9333 . . . . . . . for 8800series
LOGGER COMMUNICATOR 9334 . . . . . . for 8420
WAVE PROCESSOR 9335 . . . . . . . . . for 8800series
WIREMAP TERMINATOR 9336 . . . . . . . . . for 3660
DIRECTION TERMINATOR 9337 . . . . . . . . for 3660
CARRYING CASE 9338 . . . . . . . . . . . . . . . for 3143
CARRYING CASE 9339 . . . . . . for 3196 (soft case)
CARRYING CASE 9340 . . . . . . for 3196 (hard case)
CARRYING CASE 9344 . . . . . . . . . . for 8205, 8206
CARRYING CASE 9345 . . . . . . . . . . . . . . . for 3285
CARRYING CASE 9347 . . . . . . . . . . . . . . for 8220*
CARRYING CASE 9349 . . . . . . . . . . . . . . . for 8842
CARRYING CASE 9350 . . . . . . . . . . . . . . . for 3660
CARRYING CASE 9351 . for 3127*, 3127-11, 3100*
CARRYING CASE 9355 . . . for 3265*, 3267*, 3286
CARRYING CASE 9359 . . . . . . . . . . . . . . for 3117*
CARRYING CASE 9360 . . . for 3165* (9270~9272)
CARRYING CASE 9363 . . . . . . . . . . . . . for 3118-11
CARRYING CASE 9364 . . . . . . . . . . . . . . for 3118-12
CARRYING CASE 9371 . . . . . . . . . . . . . . . . for 3255
CARRYING CASE 9372 . . . . . . . . . for 8804*, 8806*
CARRYING CASE 9375 . . . . . . . . . . . for 9277~9279
CARRYING CASE 9376 . . . . . . . . . . . . . . . . for 3423
CARRYING CASE 9377 . . . . . . . . . . . . . . . . for 3551
CARRYING CASE 9378 . . . . . . . . . . . . . . . . for 3256
CARRYING CASE 9380 . . . . . . . . . . . . . . . . for 7011
CARRYING CASE 9382 . . . . . . . . . . . for 3550, 3555
CARRYING CASE 9384 . . . . . . . . . . . . . . . . for 3452
CARRYING CASE 9386
. . . . . . . . . . . . . . . . . . . . . for 3441, -01, -02, 3442-02, -03
CARRYING CASE 9386-01
. . . . . . . . . . . . . . . . . . . . . . for 3441, 3442, 3446, 3447
CARRYING CASE 9388 . . for 8835*, 8835-01, 3155*
CARRYING CASE 9390 . . . . . . . for 3030-10, 3030-12
CARRYING CASE 9391 . . . . . . for 8807, 8808, 8420
CARRYING CASE 9392 . . . . . . . . . . . . . . . for 3625*
CARRYING CASE 9393 . . . . . . . . . . . . . . . . for 3151
CARRYING CASE 9397-01 . . . for 8855, 8841, 8720*
CARRYING CASE 9398
. . . . . . . . . . . . . . . . . for 3280, -01*, -10, -11, 3287, 3288
CARRYING CASE 9399
. . . . . . . . . . . . . . . . . . . . for 3281, 3282, 3284, 3282-01
CARRYING CASE 9400 . . . . . . . . . . . . . . . . for 3290
AC ADAPTER 9418-10
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3167, 3551, 7011
AC ADAPTER 9418-15
. . . . . . . . . . . for 3197, 8420/21/22, 8714*/15, 8807/08
BATTERY PACK 9420 . . . . . . . . . . . for 7011, 8804*
Note: * marked products are discontinued models.
. . . . . . . . . . for 3227*, 3167*, 3187*, 3330*, 3330-02*
PRINTER INTERFACE 9589 . . . . . . for 3227*, 3560
RS-232C INTERFACE 9593-01
. . . . . . . . . . . . . . . . . . . . . . . . . . for 3522, 3531*, 3532
RS-232C INTERFACE 9593-02 . . . for 3157, 3157-01
MO UNIT 9598 . . . . . . . . . . . . . . . . . . . . . . . for 8826
MEMORY BOARD 9599 . . . . . for 8826 (48M-word)
AC/DC DIRECT INPUT UNIT 9600 . . . . . . for 3193
AC DIRECT INPUT UNIT 9601 . . . . . . . . . . for 3193
AC/DC CLAMP INPUT UNIT 9602 . . . . . . . for 3193
EXTERNAL SIGNAL INPUT UNIT 9603 . . . for 3193
9603-01 EXTERNAL SIGNAL INPUT UNIT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3194
PRINTER UNIT 9604 . . . . . . . . . . . . . . . . . . for 3193
HARMONIC/FLICKER MEASURMENTS UNIT 9605
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3193
HARMONIC MEASURMENTS UNIT 9605-01
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3194
MO UNIT 9607 . . . . . . . . . . . . . . . . . . for 8841, 8842
MEMORY BOARD(24M-WORD) 9608
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 8841, 8842
RS-232C CABLE 9612
. . . . . . . . . . for DIN 9pin-Dsub 9pin 8807, 8808, 8420
REMOTE CONTROL BOX(SINGLE) 9613
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3158, 3159
REMOTE CONTROL BOX(DUAL) 9614
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3158, 3159
H.V.TEST LEAD 9615 . . . . . . . . . . . . for 3158, 3159
H.V.TEST LEAD 9615-01
. . . . . . . . . . . . . . . . . . . . . for 3931 Red (High Voltage)
H.V. TEST LEAD 9615-03
. . . . . . . . . . . . . . . . . . . . . . . . for 3931 Black (Return)
WARNING LAMP 9616 . . . . . . . . . . . for 3158, 3159
CLIP ON BASE 9617
. . . . . . . . . . . . . . . . . for 3501, 3801, 3802, 3804, 3805
CLIP-TYPE LEAD 9618
. . . . . . . . . . . . . . . . . for 3501, 3801, 3802, 3804, 3805
POWER ANALYZER 9623 . . . . . . . . . . . . . . for 3193
PQA-HiVIEW 9624 . . . . . . . . . . . . . . . . . . . . for 3196
PQA-HiVIEW PRO 9624-10 . . . . . . . . . . . . . for 3196
POWER MEASUREMENT SUPPORT SOFTWARE 9625
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3166*, 3169
LAN CABLE 9628 . . . . . . . . . . . . . . . . . . . . for 3660
CONNECTION CABLE 9629 . . . . . . . . . . . for 3639
TEMPERATURE SENSOR 9631-01
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (1m)
TEMPERATURE SENSOR 9631-02
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (1m)
TEMPERATURE SENSOR 9631-03
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (1m)
TEMPERATURE SENSOR 9631-04
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (1m)
TEMPERATURE SENSOR 9631-05
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (30 mm)
TEMPERATURE SENSOR (9631-01,5m) 9631-11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (5 m)
TEMPERATURE SENSOR (9631-04,5m) 9631-14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (5 m)
TEMPERATURE SENSOR (9631-01,10m) 9631-21
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (10 m)
TEMPERATURE SENSOR (9631-04,10m) 9631-24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3641 (10 m)
CONNECTION CABLE 9632
. . . . . . . . . . . for 3634, 3635-04~06, 3635-24~26, 3636
CONNECTION CABLE 9633 . . . . . . . . for 3634,3635
CONNECTION CABLE 9634 . . . for 3630, 3635-01,02
VOLTAGE CORD 9635 . . . . . . . . . . . . . . . . . for 3286
VOLTAGE CORD 9635-01. . . . . . . . . . . . . . . for 3268
RS-232C CABLE 9636 . . . . . . . . . . . . . . . . . for 3286
RS-232C PACKAGE 9636-01 . . . . . . . . . . . for 3286
RS-232C CABLE (9pin-9pin/1.8m) 9637
. . . . . . . . . . . . . . . . . . . . . . . . for 3154, 3630S, 3911-20
RS-232C CABLE (9pin-25pin/1.8m) 9638
. . . . . . . . . . . . . . . . . . . . . . . . for 3154, 3630S, 3911-20
CONNECTION CABLE 9639 . . . . . . . . . . . . for 3637
CONNECTION CABLE 9641 . . . . . . . . . . . . for 8420
LAN CABLE 9642 . . . . . . . . . . . . . . . . . . . . . for 8420
CHARGE STAND 9643 . . . . . . . . . . . . . . . . . for 8420
SCSI INTERFACE 9644 . . . . . . . . . . . . . . . . for 8855
MEMORY BOARD 9645 . . . . . . . . . . . . . . . . for 8855
MEMORY BOARD 9645-01 . . . . . . . . . . . . . for 8855
MO UNIT 9646 . . . . . . . . . . . . . . . . . . . . . . . for 8855
CARRYING CASE 9648
. . . . . . . . . . . for 8807, 8808, 8420, 8421, 8714*, 8715
PROTECTIVE CASE 9649
. . . . . . . . . . . . . . . . . . . . . . for 8807, 8808, 8420, 8421
CLAMP ON SENSOR 9650
. . . . . . . . . . . . . . . . . . . . for 100A 8205, 8206, 3636-20
CLAMP ON SENSOR 9651
. . . . . . . . . . . . . . . . . . for 500A 8205*, 8206*, 3636-20
FIXED STAND 9652
. . . . . . . . . . . . . . . . . . . . . . for 8807, 8808, 8420, 8421
FIXED STAND 9652-01
. . . . . . . . . . . for 8420-50, 8421-50, 8422-50, 8807, 8808
HUMIDITY SENSOR 9653 . . . . . . . . for 8420, 8421
CLAMP ON LEAK SENSOR 9657 . . . . . . . for 3638
CLAMP ON LEAK SENSOR 9657-10
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 8808series (BNC)
CLAMP ON LEAK SENSOR 9658. . . . . . . . for 3638
CLAMP ON SENSOR 9660 . for 3196 AC100A, 3197
CLAMP ON SENSOR 9661 . for 3196 AC500A, 3197
LUX SENSOR 9662 . . . . . . . . . . . . . . . . . . . for 3640
HD UNIT 9663 . . . . . . . . . . . . . . . . . . . . . . . for 8855
10:1PROBE 9665 . . . . . . . . . . . . . . . . . . . . for 8855
100:1PROBE 9666 . . . . . . . . . . . . . . . . . . . for 8855
FLEXIBLE CLAMP ON SENSOR 9667
. . . . . . . . . . . . . . . . . . . . . . . . for 3196 AC5000A, 3197
CLAMP ON SENSOR 9668
. . . . . . . . . . . . . . . . . . . . for 8205-10/8206-10 AC1000A
CLAMP ON SENSOR 9669
. . . . . . . . . . . . . . . . . . . . . . . . for 3196 AC1000A, 3197
PRINTER 9670 . . . . . . . . . . . for 3196, 3446/47, 3197
AC ADAPTER 9671 . . . . . . . . . . . . . . . . . . . for 9670
RS-232C PACKAGE 9674 . . . . . . . . . . . for 3446/47
SMD TEST FIXTURE 9677 . . . . . . . . . . . . . for 3511
CONNECTION CABLE 9678 . . . . . . . . . . . for 3535
CONNECTION CABLE 9679 . . . . . . . . . . . for 3503
HUMIDITY SENSOR 9680-50 . . . . . . . for 3641 (1m)
HUMIDITY SENSOR 9680-51 . . . . . . . for 3641 (5m)
HUMIDITY SENSOR 9680-52 . . . . . . for 3641 (10m)
HUMIDITY SENSOR 9681 . . . . . . . . . . . . for 8420s
CARRYING CASE 9685 . . . . . . . . . . . . . . . for 3246
CARRYING CASE 9686 . . . . . . . . . . . . . . . for 3156
CLAMP ON AC/DC SENSOR 9691
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3290 AC100A
CLAMP ON AC/DC SENSOR 9692
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3290 AC200A
CLAMP ON AC/DC SENSOR 9693
. . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3290 AC2000A
CLAMP ON SENSOR 9694
. . . . . . . . . . . . . . . . . . . . . for 3169, 3196, 3197, AC5A
SMD TEST FIXTURE 9699 . . . . . . . . . . . . . for 3511
HEAD AMP UNIT 9700-10 . . . . . . . . . . . . . . for 3535
AC/DC CURRENTSENSOR 9709 . . . . . . . for 3193
CAN CABLE 9713-02 . . . . . . . . . . . . . . . . . . for 8910
LOGIC CABLE 9714-01 . . . . . . . . . . . . . . . . for 8910
LOGIC CABLE 9714-02 . . . . . . . . . . . . . . . . for 8910
CARRYING CASE 9720 . . . . . . . . . . . . . . . for 3169
RS-232C CABLE 9721 . . . . . . . . . . . . . . . . for 3169
PC CARD 128M 9726
. . . . . . . . . . . . . . . . . . . . . . . . . . for 8800S, 3169, 3196
PC CARD 256M 9727
. . . . . . . . . . . . . . . . . . . . . . . . . . for 8800S, 3169, 3196
PC CARD 512M 9728
. . . . . . . . . . . . . . . . . . . . . . . . . . for 8800S, 3169, 3196
PC CARD 1GB 9729 . . . . . . . . . . . . . . . . . for 8800s
CARRYING CASE 9730
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3661, 3662, 3663
FC CONNECTOR ADAPTER 9731 . . . . . . . for 3661
SC CONNECTOR ADAPTER 9732 . . . . . . . for 3661
FC CONNECTOR ADAPTER 9733
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3662, 3663
SC CONNECTOR ADAPTER 9734
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3662, 3663
FC-FC OPTICAL FIBER CABLE 9735
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3661, 3662, 3663
SC-SC OPTICAL FIBER CABLE 9736
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3661, 3662, 3663
SC-FC OPTICAL FIBER CABLE 9737
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3661, 3662, 3663
OPTICAL CONNECTOR CLEANER 9738
. . . . . . . . . . . . . . . . . . . . . . . . . . . for 3661, 3662, 3663
SPARE CLEANER 9739 . . . . . for 3661, 3662, 3663
OPTICAL SENSOR 9742, -01 . . . . . . . . . . . . for 3664
TEST TYPE LEAD 9750 . . . . . . . . . . . . . . . . for 3455
ALLIGATOR CLIP 9751 . . . . . . . . . . . . . . . . . for 3455
PIN-TYPE LEAD 9770
. . . . . . . . . . . . for 3239, 3540, 3541, 3555, 3560, 3561
PIN-TYPE LEAD 9771
. . . . . . . . . . . . for 3239, 3540, 3541, 3555, 3560, 3561
PIN TYPE LEAD 9772 . . . . . . . . . . . . . . . . . . for 3554
LINE SPLITTER CT-101A . . . . . . . . . for 3127-11 etc.
PAPER WINDER 220H . . . . . . . . . . .TEPTOM-220H
ALLIGATOR CLIPs
. . . . . 9170 or similar devices (used with Test Lead, inserted)
Options & Peripherals
CONNECTION CABLE 9425
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 9203, 9203-01
DC POWER ADAPTER 9433
. . . . . . . . . . . . . . . . . . . . . . . . . . for 8841, 8842, 8720*
CONNECTION CABLE 9436 . . . . . . . . . . . for 3423*
CONNECTION CABLE 9437 . . . . . . for 8927(8845)*
VOLTAGE CORD 9438 . . . . . . . . . . . . . . . . for 3166*
VOLTAGE CORD 9438-02. . . . . . . . . . . . . . . for 3196
VOLTAGE CORD 9438-03, -05 . . . . . . for 3169, 3197
DC POWER ADAPTER 9439 . . . . . . . . . . . . for 8835
CONNECTION CABLE 9440 . . . . for 3166*, 3169-01
CONNECTION CABLE 9441 . . . . for 3166*, 3169-01
PRINTER 9442 . . . . . . . . . . . . . . . . . . . . for 3443, 44
AC ADAPTER 9443-02
. . . . . . . . . . . . . for 3166*, 3330-02*, 3332, 3511, 3154
AC ADAPTER 9443-03
. . . . . . . . . . . . . for 3166*, 3330-02*, 3332, 3511, 3154
CONNECTION CABLE 9444
. . . . . . . . . . . for 3154, 3166*, 3196, 3332, 9442, 3511
AC ADAPTER 9445-02 . . . . . . . . . for USA, CANADA
AC ADAPTER 9445-03 . . . . . . . . . . . . . . . . . . . for EU
CONNECTION CABLE 9446
. . . . . . . . . . . . . . . . . . . . . . . . . . for 3522, 3532, 3330*
BATTERY PACK 9447 . . . . . . . for 8807, 8808, 8420
TEMPERATURE PROBE 9451 . . . . . . . . . . for 3540
CLIP TYPE LEAD 9452. . . . . . . . . . . . for 3560, 3540
FOUR TERMINAL LEAD 9453 . . . . . . for 3560, 3540
ZERO ADJUSTMENT BOARD 9454
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3551, 3560
PIN TYPE LEAD 9455
. . . . . . . . . . . . . . . . . . . . for 3226*, 3227*, 3540, 3560
AC ADAPTER 9458 . . . . . . . . . . . . . . . . . . . for 3196
BATTERY PACK 9459 . . . . . . . . . . . . for 3196, 3197
CLIP TYPE LEAD WITH TEMPERATURE SENSOR 9460
. . . . . . . . . . . . . . . . . . . . . . . . . for 3550, 3551, 3551-03
PIN TYPE LEAD 9461 . . . . . . . for 3155*, 3555, 3540
THERMISTER TEMPERATURE PROBE 9462
. . . . . . . . . . . . . . . . . . . . . . . . for 3281*, 3282, 3282-01
HUMIDITY SENSOR 9463 . . . . . . . . . . . . . for 3625*
HUMIDITY SENSOR 9464 . . . . . . . . . . . . . for 3625*
PIN TYPE LEAD 9465
. . . . . . . . . . . . . . . . . for 3550, 3551, 3552, 3555, 3540
PIN TYPE LEAD 9465-10 . . . . . . . . . . . . . . . for 3554
REMOTE CONTROL SWITCH 9466
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3551, 9465
LARGE CLIP TYPE LEAD 9467
. . . . . . . . . . . . . . . . . . . . . . . . . for 3550, 3226*, 3227*
SHEATH TYPE TEMPERATURE PROBE 9472
. . . . . . . . . . . . . . . for 3441, -01, -02, 3442-02, -03, 7015*
SHEATH TYPE TEMPERATURE PROBE 9472-50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3446 (K)
SHEATH TYPE TEMPERATURE PROBE 9473
. . . . . . . . . . . . . . . for 3441, -01, -02, 3442-02, -03, 7015*
SHEATH TYPE TEMPERATURE PROBE 9473-50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3446 (K)
SHEATH TYPE TEMPERATURE PROBE 9474
. . . . . . . . . . . . for 3441, -01, -02, 3442-02, -03, 7015* (K)
SHEATH TYPE TEMPERATURE PROBE 9475
. . . . . . . . . . . . for 3441, -01, -02, 3442-02, -03, 7015* (K)
SURFACE TYPE TEMPERATURE PROBE 9476
. . . . . . . . . . . . for 3441, -01, -02, 3442-02, -03, 7015* (K)
SURFACE TYPE TEMPERATURE PROBE 9476-50
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3446 (K)
SHEATH TYPE TEMPERATURE PROBE 9478
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3447 (PT-100)
SHEATH TYPE TEMPERATURE PROBE 9479
. . . . . . . . . . . . . . . . . . . . for 3447 (PT-100 with switch)
NETWORK A 9496 . . . . . . . . . . . . . . . . . . . for 3155*
NETWORK B 9497 . . . . . . . . . . . . . . . . . . for 3155*
NETWORK C 9498 . . . . . . . . . . . . . . . . . . for 3155*
NETWORK D 9499 . . . . . . . . . . . . . . . . . . for 3155*
4 TERMINAL PROBE 9500 . . . . . . . . . . . . . . for LCR
GP-IB INTERFACE 9517 . . . . . . . . . for 3186, 3227*
GP-IB INTERFACE 9518-01
. . . . . . . . . . . . . . . . . . . . . . . . . . for 3511, 3531*, 3532
GP-IB INTERFASE 9518-02
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3157, 3157-01
FUNCTION UP DISK 9540-01
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 8835-01
FUNCTION UP DISK(POWER MONITOR) 9549
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 8855
SENSOR UNIT 9555 . . . . . . . . for 9270, 9271, 9272
RS-232C CARD 9557
. . . . . . . . for 8826, 8835*, 8835-01, 8841, 8842, 8720*
GP-IB CARD 9558
. . . . . . . . for 8826, 8835*, 8835-01, 8841, 8842, 8720*
INPUT CORD 9574 . . . . . . . . . . . . . for 8944(8851)*
GP-IB INTERFACE 9588
64
HIOKI - Offering Top Quality Products and Services
HIOKI E.E. CORPORATION TRACEABILITY CHART
National
Standards
Comparative standards
M
a
k
e
r
N
I
S
T
STANDARD
CALIBRATOR
Q
A
A
AC/DC VOLTAGE
CURRENT STANDARD
S
J
E
M
I
C
CURRNET
TRANSFORMER
RESISTANCE
CALIBRATOR
HIGH VOLTAGE
DIVIDER
T
STANDARD
RESISTOR
Calibrated
parameter
�AC/DC voltage
0 to 1000 V
�AC/DC current
0 to 100A
STANDARD
RESISTOR
ELECTROMETER/
SOURCE
WHEATSTONE
BRIDGE
�High voltage
1mΩ to 30kV
�DC resistance
1mΩ to 1MΩ
STANDARD VARIABLE
RESISTOR
HIGH RESISTANCE
STANDARDS
T
E
L
E
C
R
T
Japan Quality Assurance
Organizaton
JEMIC =
Japan Electric Meters
Inspection Corporation
CRL =
Communications Research
Laboratory
TELEC =
Telecom Engineering
Center
Traceability allows us to manage and maintain instrument
accuracy characteristics that are tied to recognized national
and international standards. How they are managed and
maintained are dependent on the measurement facilities
that offer accuracy testing at the various levels, skilled
�AC power
standards, manufacturer reference equipment, field
technicians, as well as a strong link between national
PHASE METER
STANDARD SELFINDUCTOR
STANDARD SELFINDUCTOR
� Inductance
The HIOKI Traceability System as indicated by the chart on
STANDARD
CAPACITOR
�Capacitance
the left is strictly managed by accounting for each individual
STANDARD
CAPACITOR
�AC resistance
instrument - from reference instruments to field equipment
�Illuminance
- and their constant accuracy. As scientific techniques and
LCR METER
ILLUMINANCE METER
CALIBRATOR
STANDARD LAMP
UNIVERSAL
COUNTER
STANDARD DIGITAL
THERMOMETER
STANDARD GLASS
THERMOMETER
SYNTHESIZER
UNIVERSAL
COUNTER
FUNCTION
GENERATOR
measuring instruments, and basic measuring instruments.
�Phase
manufacturing technology continue to expand and develop,
�Time
�Frequency
DIGITAL
THERMOMETER
�Temperature
TEMPERATURE
CALIBRATOR
we will strive to meet new demands by not only providing
the appropriate measuring instruments for our users,
but also enhancing the accuracy in our test instruments
and maintaining our Traceability System so that they are
constantly on par with global standards.
DEW POINT
MONITOR
�Humidity
GAGE BLOCK
MULTIMETER
CALIPER CHECKER
SLIDE CALIPERS
�Length
Note:Only the primary standards are indicated above. For details, please refer each product's TRACEABILITY CHART.
Please also note that the naming of the standards indicated in this chart may differ from the naming used in
each product's TRACEABILITY CHART.
HIOKI's Calibration System
In order to provide dependable and quality-assured products, HIOKI
has acquired the international standard ISO/IEC17025 certification for
calibration, which allows us to meet a wide variety of calibration needs.
By regularly calibrating HIOKI instruments using reference calibrating
equipment traceable to national standards while complying with the
reference equipment organizational chart, customers are guaranteed
complete accuracy. After purchase, it is highly recommended that
customers regularly re-calibrate their HIOKI instruments to maintain
their accuracy. Depending on your needs, calibration and adjustment
can be conducted at HIOKI in one of 4 ways as illustrated on the right.
65
are indispensable.
PHASE METER
AIST =
National Institute of
Advanced Industrial
Science and Technology
management system that reaches to the national standards
STANDARD POWER
METER
NIST =
JQA =
accountability in the form of a coherent and comprehensive
STANDARD WATT
CONVERTER
STANDARD
CAPACITOR
National Institute of
Standards and Technology
instrument. To maintain accuracy, traceability and
�High resistance
106 to 10Ω10
AC GENERATOR
C
Accuracy can be regarded as the heart of a measuring
MULTIMETER
POTENTIAL
TRANSFORMER
I
Applied standards
MULTIMETER
THERMAL TRANSFER
STANDARD
STANDARD SHUNT
J
Intermediate standards
About our Company
Established in 1935, HIOKI E. E. CORPORATION has grown to be a
leading developer and manufacturer of advanced test and measurement
technologies for use both in the field and leading edge facilities around
the world. Our goal is simple: contribute to the advancement of society,
while making sure the natural environment is not compromised. As
a reliable producer and member of society, we pledge to continue to
actively contribute to the cultural and educational development of the
local community through activities such as greening efforts, scholarship
programs and sponsoring children's sports teams. With the support of our
customers and worldwide network, we are confident that our values and
beliefs, and products and services, will be brought forth through the 21st
century and beyond.
Internet website
Corporate History
1935
1945
1946
1952
1965
1975
1983
1990
1991
1992
1993
1997
1998
2001
2003
2005
2006
HIOKI starts manufacturing electrical measuring instruments in Tokyo
Move to Nagano Prefecture due to war
Tester No.1 put to market
HIOKI E.E. CORPORATION established
Designated as the manufacturer of MULTITESTER (MIL Standard) for the
U.S. Far East Air Forces
Mass production of VU instruments for recording level adjustments to tape
recorders
Independent development and sale of instruments with internal magnetic
taut bands
Multiple awards received for innovative clamp-style instruments
Move to HIOKI Forest Hills
Registered on the over-the-counter market
Awarded the Afforestation Center Presidential Award for positively
promoting afforestation
ISO9001 certified
ISO14001 certified
HIOKI USA CORPORATION established
HIOKI Shanghai Representative Office established
Listed on the Second Section of the Tokyo Stock Exchange
Listed on the First Section of the Tokyo Stock Exchange
"Solution Fair" - 70th Anniversary Celebration
THT Technology Joint Venture in Taiwan established
HIOKI Tianjin Representative Office established
"Solution Factory" Building B Completed
Electronic Measuring Instruments Business Segment of DKK-TOA
Corporation acquired
HiNSTEC Corporation established
www.hioki.com
66
HEAD OFFICE:
HIOKI USA CORPORATION:
81 Koizumi, Ueda, Nagano
386-1192, Japan
TEL+81-268-28-0562
FAX+81-268-28-0568
E-mail: [email protected]
6 Corporate Drive
Cranbury, NJ 08512 USA
TEL+1-609-409-9109
FAX+1-609-409-9108
E-mail: [email protected]
Shanghai Representative Office:
1904 Shanghai Times Square Office
93 Huaihai Zhong Road, Shanghai, 200021, P.R.China
TEL +86-21-6391-0090/0092
FAX +86-21-6391-0360
E-mail: [email protected]
DISTRIBUTED BY
All information correct as of April 1, 2007. All specifications are subject to change without notice.
This brochure has been printed on recycled paper
with special ink blended with recycled soy oil.
0001E 39-74B-14K
Printed in Japan
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement