EVE - ETIREL Technical data Build-in switch SV Technical data Type 16A-40A Electrical Number of poles Rated operational voltage Ue Rated current In Rated Insulation voltage Ui Rated impulse withstand voltage Uimp Utilization category Rated frequency Rated short-time withstand current Icw Rated short-circuit making capacity Icm Rated conditional short-circuit current Rated making capacity Rated breaking capacity Switch Type Standard 1p, 2p, 3p, 4p 230/400V AC (1p), 400V AC (2p, 3p 4p) 16, 25, 40A 1000V 4 kV AC-23B 50/60Hz 800A 500A 2000A (with 50A fuse) 400A 320A Build-in switch IEC/EN 60947-3 Mechanical Device height Device width Degree of protection Terminal capacity Terminal screw Terminal torque Operating temperature Storage- and transport temperature Contact position indicator Supply possibility 68mm (DIN rail acc to EN60715) 18mm/p IP20 1-25mm2 M5 (Pozidrive PZ2) max 3Nm -25°C ... +55°C -40°C ... +70°C mechanical red/green Top or bottom In≥63A 1 02 Tehnical data.indd 109 109 9/2/2016 1:43:02 AM EVE - ETIREL Technical data Technical data Type 63-125A Electrical Number of poles Rated operational voltage Ue Rated current In Rated Insulation voltage Ui Rated impulse withstand voltage Uimp Utilization category Rated frequency Rated short-time withstand current Icw Rated short-circuit making capacity Icm Rated conditional short-circuit current Rated making capacity Rated breaking capacity Switch Type Standard 1p, 2p, 3p, 4p 1p: 230/400V AC, 24V DC 2p: 400V AC, 48V DC 3p, 4p: 400V AC 63, 80, 100, 125A AC: 1000V; DC:1500V 4 kV AC-22B; DC-22B 50/60Hz AC, DC 1500A / 1s 2200A peak 4,0kA (with 100A fuse) / 2,5kA (with 125A fuse) 400A 320A Build-in switch-disconnector IEC/EN 60947-3 Mechanical Device height Device width Degree of protection Terminal capacity Terminal screw Terminal torque Operating temperature Storage- and transport temperature Contact position indicator Supply possibility 68mm (DIN rail acc to EN60715) 18mm/pole IP20 1-50mm2 M6 (Pozidrive PZ2) max 3Nm -25°C ... +55°C -40°C ... +70°C mechanical red/green Top or bottom In<63A 1 110 02 Tehnical data.indd 110 9/2/2016 1:43:04 AM EVE - ETIREL Technical data Build-in devices ”EVESYS” Technical data Rated voltage Un Rated current In Rated frequency fn Terminals Width of the switch Standards 230/400 V AC, 24 V DC 16 A, 25 A 50/60 Hz 1,5 - 6 mm2 17,5 mm IEC 60947-1, EN 60947-1, IEC 60947-3 EN 60947-3, IEC 60947-5-1, EN 60947-5-1 Switch Switch with control light Change-over switch 1 1 3 1 3 5 1 3 5 7 1 3 1 3 7 1 3 5 7 2 1P 2 4 2P 2 4 6 3P 2 4 6 8 4P 2 1P 2 2 7 5 1 3 1 3 5 8 2 4 1P 2 4 6 2P 1 3 1 3 II 0I 8 1 3 6 8 1 3 7 5 2 1P 2 7 1 3 1 3 5 7 8 2 4 2P 2 4 6 4P 8 2P 3P 8 2P II0I 2 1P 2 2P Center-off Change-over Switch Control Switch Push-button 45 5 max. 1,5W 68 1 58 42.5 5 7 2 6.2 6 8 2P 87.5 Push-button with Control Light Signal Light L1 02 Tehnical data.indd 111 111 9/2/2016 1:43:07 AM 3 47,5 56 42,5 1 57,5 45 3 1 2 2 35,8 80 35,8 80 Signal light 2 SS 220 Bell/Buzzer 2M 45 10.5 58 63 33 43,7 45 48.7 54 36 63 3M 43.7 58 47,5 57,5 45 42,5 52,5 EVE - ETIREL Technical data 90 36 54 90 78.5 Bell transformer type 3M Bell transformer type 2M DIN socket 112 02 Tehnical data.indd 112 9/2/2016 1:43:08 AM EVE - ETIREL Technical data Power relays VS116K, VS316K Symbol Technical data VS116K Supply terminals Voltage range Burden Supply terminals Voltage range Burden Supply voltage tolerance Output Number of contacts Current rating Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life (AC1) Time between switching Other information Operating temperature Storage temperature Electrical strength Operating position Mounting/DIN rail Protection degree Overvoltage category Pollution degree Max. cable size (mm2) Dimensions Weight Standards 230 V AC/5060 Hz AC max. 7.5 VA/ 1W A1-A3 24 V AC/DC (50-60 Hz) 1 VA AC/ 1W DC VS316/24 A1 - A2 24 V AC/DC/ 50-60 Hz 1.6 VA/ 1.2 W VS316/230 230 V AC/ 50-60 Hz 2.5 VA x x VS116K A1 12 14 A2 A3 11 VS316/24 x VS316/230 12 A1 24 32 34 14 22 A1 12 14 22 24 32 34 -15%; +10% 1 x changeover/ SPDT (AgSnO2) 16 A/ AC1 4000VA/ AC1, 384W/ DC 30 A/ <3s 3x107 0.7x105 min. 2s 3 x changeover/ 3PDT (AgSnO2) 11 A2 21 31 A2 11 21 31 16A/ AC1 4000VA/ AC1, 384W/ DC 30 A/ <3s 250 V AC1/ 24 V DC 500 mW high intensity of LED 1x107 1x105 20 ms 50 ms Description VS116K Supply terminals A2 A3 A1 -20 °C ... +55 °C (-4 °F ... 131 °F) -30 °C ... +70 °C (-22 °F ... 158 °F) 4 kV (supply-output) any DIN rail EN 60715 IP 40 from front panel III. 2 max.1x 2.5 / 2x1.5 max. 1x2.5 90 x 17.6 x 64 mm (3.5˝ x 0.7˝ x 2.5˝) 54 g (1.9 oz.) 90 g (3.17 oz.) 92 g (3.25 oz.) EN 61810-1, EN 61010-1 Indication LED Red/čevená 12 11 14 Output changeover contact terminal A3 only for VS116K Notes Max. time of changeover of contact is 10ms. VS316/24 and VS316/230 enable switching of different phases or 3 phase voltage. VS316/24, VS316/230 21 22 2nd output changeover contact Supply terminals 24 A1 A2 Indication LED 31 02 Tehnical data.indd 113 11 12 32 34 14 Output changeover contact 3rd output changeover contact 113 9/2/2016 1:43:10 AM EVE - ETIREL Technical data Delay OFF without supply voltage CRM-82TO Symbol Technical data Number of functions Supply terminals Voltage range Burden Supply voltage tolerance Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coeffi cient Output Number of contacts Current rating Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life (AC1) Other information Operating temperature Storage temperature Electrical strength Mounting/DIN rail Protection degree Operating position Overvoltage category Pollution degree Max. cable size(mm2) Dimensions Weight Standards CRM-82TO a - On Delay (Power On)/ e - Off Delay (S Break) A1 - A2 12 - 240 V AC/DC(AC 50 - 60 Hz) 0.7 - 3 VA AC/ 0.5 - 1.7 W DC -15 %; +10 % green LED 0.1 s - 10 min potentiometer 5 % - mechanical setting 0.2 % - set value stability 0.01 % / °C, at = 20 °C ( 0.01 % / °F, at = 68 °F) 2x changeover/SPDT (AgNi/ Silver Alloy) 8 A / AC1 2000 VA / AC1, 192 W / DC 10 A / <3 s 250 V AC1 / 24 V DC 500 mW red LED 3x107 0.7x105 16 A1 A2 18 15 26 28 25 Connection Un A1 A2 16 26 18 28 15 25 Description Supply terminals A1 Output contact A2 26 16 Output indication CRM-82TO Supply indication Rough time setting -20 °C ... +55 °C (-4 °F ... 131 °F) -30 °C ... +70 °C (-22 °F ... 158 °F) 4 kV (supply-output) DIN rail EN 60715 IP 40 from front panel / IP 10 terminals any III. 2 solid wire max. 2x2.5 or 1x4 ( AWG 12 ) with sleeve max. 2x1.5 or 1x2.5 ( AWG 12 ) 90 x 17.6 x 64 mm (3.5˝ x 0.7˝ x 2.5˝) 93 g (3.3 oz.) EN 61812-1, EN 61010-1 Fine time setting Function setting FUNC e 28 18 15 a Output contact 25 Output contact Function a - Delay OFF (S break) the power supply U t ON U t t 114 02 Tehnical data.indd 114 9/2/2016 1:43:12 AM EVE - ETIREL Technical data Multifunction time relay CRM-91H, CRM-93H Connection Technical data CRM-91H Number of functions Supply Supply voltage Consumption Supply indication Time ranges Time settings Time deviation Repeat accuracy Temperature coefficient Output Changeover contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Controlling voltage Consumption of output Load between S-A2 Glow-tubes Control. terminals Impulse length Reset time Operating temperature Storing temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards CRM-93H 10 A1-A2 12-240 V AC/DC(50-60 Hz AC) AC 0,7-3 VA / DC 0,5 - 1,7 W green LED 0.1 s-10 days rotary switch 5%-mechanical setting 0,2%-set value stability 0,01% / °C at 20 °C 1 3 16 A / AC1 8 A / AC1 4000 VA / AC1, 2000 VA / AC1, 384 W /DC 192 W / DC 30 A / <3 s 10 A / <3 s 250 V AC1 / 24 V DC 500 mW multifunction red LED 3x107 0,7x105 12-240 V AC/DC 0,025-0,2 VA AC/ 0,1-0,7 W DC A1-S min. 25 ms/ max. unlimited max. 150 ms -20...+55 °C -30...+70 °C 4 kV any DIN rail EN 60715 IP 40 from frontal panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 61812-1, EN 61010-1 CRM91-H CRM-93H Load with control input possible. Load between S-A2 possible to connect in parallel way, without disturbing of proper operation of the relay. Dimensions CRM-91H CRM-93H CRM-2H 1-MODULEdesign DESIGN 1-module CRM-4 MR-41 02 Tehnical data.indd 115 MR-42 S 115 3-MODULE DESIGN 9/2/2016 1:43:14 AM SHT-2 EVE - ETIREL Technical data Functions a) Delay ON after energisation b) Delay OFF after energisation c) Cycler beginning with pause after energisation d) Cycler beginning with impulse after energisation e) Delay OFF after de-energisation, instant make of output f) Delay OFF responding to make of control contact regardless its length g) Delay OFF after break of control. contact with instant output h) Delay OFF after make and break of control. contact i) Memory (latching) relay j) Pulse generator Description Time ranges Supply terminals Control. input S day Supply indicator Rough time setting Output indication - multifunction LED Examples of signalling Function: days Fine time setting Function setting Function: only ON Output contact only OFF 116 02 Tehnical data.indd 116 9/2/2016 1:43:15 AM EVE - ETIREL Technical data Time relay CRM-2H Technical data Connection Number of functions Supply m 10 1 h 1 10 Supply voltage Consumption Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient Output Changeover contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Reset time Operating temperature Storage temperature Electrical strength Operating position Mounting/DIN rail Protection degree Overvoltage category Pollution degree Max. cable size h h 1 10 1 10 m m 10Dimensions 10 1 d 1 1 10 10 10 Standards10030 S S 1 d 10 10 S 1 30 100 1 0.1 - 1 s m 10 1 h 1 10 m 1 d 10 10 S 1 10 1 h 1 10 Time ranges 10 S 1 30 100 1 - 10 h 1 16A / AC1 4000 VA / AC1, 384 W /DC 30 A / <3 s 250 V AC1 / 24 V DC 500 mW multifunction red LED 3x107 0,7x105 max. 150 ms -20...+55 °C -30...+70 °C 4 kV (supply-output) any EN 60715 IP 40 from frontal panel III 2 2,5 mm2 h 1 10 m d 10 mm2 1 d 1 90x17,6x64 1 10 10 10 30 61812-1, 30 EN EN 61010-1 S 100 30 100 h 1 10 0.1m -101 day 1 1 d 10 10 S 1 30 100 m 10 1 h 1 10 30 100 1 1 - 10m days 10 10 1 h 1 10 h 10 10 1 h 1 10 10 S 1 30 100 30 100 m 3 - 30 days 10 10 S 1 30 100 1 - 10 h Supply terminals h 1 10 Output indication Fine time setting-PULSE 30 100 m 10 1 h 1 10 10 S 1 h 1 10 0.1 - 1 day 15-18 t1 t2 LED Terminal for function select Supply indication 10 1 1 10 10 S 1 1 d 10 30 100 Output indicat TIME 2 CRM-2H Un 30 100 h 1 10 10 S 1 30 100 m 10 1 h 1 10 10 30 CRM-91H S 100 CRM-93H 1 1 d 10 30 100 3 - 30 days h 1 10 1 d 10 10 S 1 1 - 10 min 10 1 10 1 h 1 10 10 S 1 Rough time setting-PAUSE 30 100 m m m m 10 - 100 days 10 1 - 10 days 30 100 TIME 1 U 1 d 10 30 100 TIME 1 15-18 10 1 10 S 1 1 10 1 d 10 30 100 TIME 2 Fine time setting-PAUSE h 1 10 Dimensions 1 d 10 30 100 Output cont CRM-2H 10 - 100 days 3-MODULE DESIGN 117 CRM-4 t2 30 100 0.1 - 1 h m Output contact 10 1 10 S 1 1-module design 1-MODULE DESIGN 02 Tehnical data.indd 117 t1 LED Fine time setting-PULSE 1 d 10 10 S 1 1 d 10 U 1 d 10 Fine time setting-PAUSE 30 100 10 1 h 1 10 Rough time setting-PULSE 1 d 10 10 S 1 10 S 1 10 1 10 S 1 Rough time setting-PAUSE 1 10 1 m m 0.1 - 1 min 1 d 10 Un Rough time setting-PULSE 1 h 1 10 Supply termin CRM-2H 1 d 10 m Terminal for function selection Supply indication m h 1 10 Cycler beginning with pause Description 1 d 10 1 - 10 s 10 1 Cycler beginning with pulse 0.1 - 1 h 1 d 10 10 S 1 1 m 1 d 10 10 S 1 m 1 d 10 0.1 - 1 s m Functions 1 - 10 min 1 d 10 10 S 1 100 1 0.1 - 1 min 1 d 10 Cycler beginning with pause 12-240 V AC/DC (50-60 Hz AC) AC 0,7-3 VA / DC 0,5 - 1,7 W green LED 0.1 s-100 days rotary switch and potentiometer 5% mechanical setting 0,2% set value stability 0,01% / °C -> 20 °C 1 1 - 10 s Cycler beginning with pulse 2 A1-A2 MR-41 MR-42 SOU-1 9/2/2016 1:43:18 AM EVE - ETIREL Technical data Delay ON star/delta CRM-2T Connection Technical data CRM-2T 1 A1-A2 AC/DC 12-240 V (AC 50-60 Hz) AC 0,7-3VA/DC 0,5-1,7 W -15% - +10% green LED t1: 0.1 s - 100 days Number of functions Supply Universal supply Consumption Supply voltage tolerance Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient Output Number of contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Reset time Controlling Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards start up of motor ( - ) start of a motor (Motor) S1 S3 auxiliary supply S2 A1 A2 CRM-2T rotary switch and potentiometer 5%-mechanical setting 0,2%-set value stability 0,01% / °C at 20 °C 25 26 28 15 16 18 (motor) S1 2 x changeover (AgNi) 16 A / AC1 4000 VA / AC1, 384 W / DC 30A/<3s max. 250 V AC1 / 24 V DC 500 mW multifunction red LED 3x107 0.7x105 max. 150 ms. 18 16 A1 A2 15 26 S2 S3 28 25 Functions Delay ON star/delta U t1 15-18 -20...+55 °C -30...+70 °C 4 kV any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 61812-1, EN 61010-1 t2 25-28 Description Supply terminals Output indication multifunction LED A2 A1 Supply indication U 15-18 25-28 LED Rough time setting t1 Fine time setting t1 t1 t2 230 V LED Fine time setting t2 24-480V 28 25 15 18 Output contact Output contact Time ranges m 10 1 10 S1 h 1 10 1 d 10 30 100 m 10 1 10 S1 0.1 - 1 s m 10 1 10 S1 h 1 10 1 d 10 30 100 m 10 1 10 S1 1 - 10 s 1 d 10 30 100 1 - 10 hrs h 1 10 m 10 1 10 S1 h 1 10 h 1 10 1 d 10 30 100 m 10 1 10 S1 0.1 - 1 min 1 d 10 30 100 0.1 - 1 day m 10 1 10 S1 h 1 10 1 d 10 30 100 1 - 10 days h 1 10 1 d 10 30 100 m 10 1 10 S1 1 - 10 min m 10 1 10 S1 h 1 10 1 d 10 30 100 3 - 30 days h 1 10 1 d 10 30 100 0.1 - 1 h m 10 1 10 S1 h 1 10 1 d 10 30 100 10 - 100 days 118 02 Tehnical data.indd 118 9/2/2016 1:43:21 AM EVE - ETIREL Technical data Staircase switch CRM-4 Connection Technical data Function Supply Supply voltage Consumption Supply voltage tolerance Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient Output Changeover contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Control. voltage Consumption of input Load between S-A2 Glow-tubes Control. terminals Impulse length Reset time Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards delay OFF A1-A2 230 V AC/50-60 Hz max. 12 VA AC/1.8 W - 15%; + 10% green LED 0,5 - 10 min potentiometer 10% mechanical setting 5% set value stability 0,05% / °C -> 20 °C 1 16 A / AC1 4000 VA / AC1, 384 W /DC 30 A / <3 s 250 V AC1 / 24 V DC 500 mW red LED 3x107 0,7x105 230 V AC 0,53 VA AC yes yes, max. 20 pcs. (at 1 mA) A1-S min. 25 ms/max. unlimited max. 150ms -20...+55 °C -30...+70 °C 4 kV (supply - output) any DIN rail EN 60715 IP 40 from frontal panel III 2 2,5 mm2 90x17, 6x64 mm EN 60669-2-3, EN 61010-1 3-wire connection 4- wire connection L L N N A1 S A2 A1 S A2 max. 20mA 250V AC1 16A/4000VA 250V AC1 16A/4000VA 15 16 18 15 16 18 Description Supply terminals Controlling contact CRM-4 Supply indication Output indication Un ON Function setting AUTO CRM-91H CRM-93H OFF t [min] 0.5 Time setting 10 Output contact switch Dimensions CRM-4 MR-41 1-module 1-MODULEdesign DESIGN 3-MODULE DESIGN 02 Tehnical data.indd 119 119 SHT-2 9/2/2016 1:43:23 AM EVE - ETIREL Technical data Programmable staircase switch CRM-42 Connection Technical data Functions Supply Supply voltage Consumption Supply voltage tolerance Supply indication Time ranges Time setting Time deviation Repeat accuracy Temperature coefficient Output Number of contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Reset time Controlling Control Voltage Input consumption Glow tubes Control terminals Impulse length Reset time Operating temperature Storage temperature Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards CRM-42 delay OFF responsive to control contact switch on A1-A2 230 V AC / 50-60Hz max. 12VA AC / 1.8 W -15% - +10% green LED 0.5 - 10 min. potentiometer 5%-mechanical setting 5%-set value stability 0,05% / °C at 20 °C 1, (AgSnO2), switching potential A1 16 A / AC1 4000 VA / AC1, 384W / DC 30A / < 3s. max. 250 V AC1 / 24 V DC 500 mW red LED 3x107 0.7x105 max. 150 ms. 3-wire connection 4-wire connection Functions funkc. ON Function ON red LED Function AUTO red LED 230 V AC 0.53 VA AC yes, max. 100 pcs. (at 1mA) A1-S / A2-S min 50ms. / max.unlimited max. 150 ms. -20...+55 °C -30...+70 °C any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 60669-2-3, EN 61010-1 Function PROG red LED Description Supply terminals Control terminal S Supply indication Output indication Function settings Time setting Supply terminals Output contacts 120 02 Tehnical data.indd 120 9/2/2016 1:43:25 AM EVE - ETIREL Technical data Digital time switch SHT-1, SHT-1/2, SHT-3 and SHT-3/2 Controlling elements Technical data Supply terminals Supply voltage Consumption Supply voltage Consumption Supply voltage tolerance Back-up supply Summer/winter time Output Number of contacts A1-A2 12 - 240 V AC/DC (50 AC - 60 Hz) UNI 0,5 - 2 VA AC/ 0,4 - 2 W DC 230 V AC/50 - 60 Hz 230 max. 14 VA AC / 2 W -15%; +10% yes automatic 1x CO SHT-1, SHT-3; 2X CO SHT-1/2, SHT-3/2 Rated current 16 A / AC1 Breaking capacity 4000 VA /AC1, 384 W / DC Inrush current 30 A / < 3 s Switching voltage 250 V AC1 /24 V DC Min. breaking capacity DC 500 mW Mechanical life >3x107 >0,7x105 Electrical life (AC1) Time circuit Power back-up 3 years max. +/-1s/dat / 23°C Accuracy 1s Minimum interval Data stored for min. 10 years Program circuit Program SHT-1, SHT-1/2 daily, weekly Program SHT-3, SHT-3/2 daily, weekly, monthly, yearly Data readout LCD display Other information -20...+55°C Operating temperature -30...+70°C Storage temperature Electrical strength 4 kV (supply-output) Operating position any Mounting DIN rail EN 60715 IP 20 Protection degree III Overvoltage category 2 Pollution degree max. 2x1,5 mm2, 2x2,5 mm2 Max. cable size 90x35, 6x64mm Dimensions EN 61812-1, EN 61010-1 Standards Selection of switch on mode Day of the week Pulse output Signalling ON/OFF Winter/summer time Mode random switching Supply term (A1) The time is shown on bragraf Mode manual switching Description Supply terminal (A1) Channel 1 (SHT-1, SHT-3) (16-15-18) A1 16 15 Reset Un Display A2 SHT-1 Controlling buttons Reset Supplyterminals (A2) Channel 2, (SHT-1/2, SHT-3/2) (26-25-28) Connection SHT-1, SHT-3 SHT-1/2, SHT-3/2 Dimensions 02 Tehnical data.indd 121 Display 18 121 9/2/2016 1:43:28 AM Supply term (A2) EVE - ETIREL Technical data Analog electromechanical time switch APC-D1, APC-DR1 Technical data Supply voltage Power reserve Dial/minimum switching time Operating accuracy Program Output contact Switching capability Power consumption Operating temperature Mounting Protection category Overvoltage category Dimensions Standards APC-DR1 230V AC yes (100 hrs) 15 min +/- 1s/day at 220C Daily 1 x NO 16A 125/250V AC1 0,5W -25...+550C DIN rail EN 60715 IP20 II. 90 x 17,5 x 66 EN 60730-2-7 Connection APC-D1 230V AC no 15 min +/- 1s/day at 220C Daily 1 x NO 16A 125/250V AC1 0,5W -10...+450C DIN rail EN 60715 IP20 II. 90 x 17,5 x 66 EN 60730-2-7 Dimensions Programming Multifunction relays SMR-T, SMR-H, SMR-B Technical data Number of functions Connection Supply voltage Consumption (no operation/make) Supply voltage tolerance Time ranges Time setting via Time deviation Repeat accuracy Temperature coefficient Output Resistive load Inductive load Controlling Voltage Current Impulse length Operating temperature Operating position Mounting Protection degree Overvoltage category Pollution degree Fuse Outlets Glow-laps in button (pcs) Dimensions Standards SMR-T 9 3-wires, without neutral SMR-H 9 4-wires, with neutral 230 V AC / 50-60 Hz 0,8/3 VA 0,8/3 VA - 15%; + 10% 0,1 s-10 days 0,1 s-10 days via rotary switch and potentiometer via rotary switch and potentiometer 10% mechanical setting 10% mechanical setting 2% set value stability 2% set value stability 0,1%, °C at 20 °C 0,1%, °C at 20 °C 1x triac 10-160 VA 0-200 VA 10-100 VA 0-100 VA F1 A / 250 V 230 V AC 3 mA min. 50 ms/ max. unlimited 0...+50 °C any free at connecting wires IP 30 from front panel III 2 F1 A / 250 V 3 x solid wires 0,75 mm2 length 90 mm max. 10 48,5 x 48,5 x 13 mm EN 61010-1 SMR-B 10 4-wires, with neutral 3 VA x x x x x 10-300 VA 10-150 VA F1,6 A / 250 V 122 02 Tehnical data.indd 122 9/2/2016 1:43:30 AM EVE - ETIREL Technical data Function Function a - delay off on entrering edge Function f - delay on S output times when it is switched. Each following pressing (max. 5x) increases time Long pressing switches output off V t S delay on after switch is switched on until it is switched off 2xt t V Function g - pulse relay switches on by a press, another pressing switches the output S off . The length of pressing doesn’t matter, it is possible to V set reaction delay by a potentiometer and thus eliminate rebound of a button S Function b - delay off on downward edge output times after button is switched off , switches immediately V Function c - delay off on downward edge S after switching off output switches on and times. V Function d - cycler - flasher impulser S output cycles in regular interval, cycler starts with an impulse Function e - puls shift t one press switches on, another one switches the output off in case it is done before the end of timing t V t t t t t V t V output cycles in regular intervals, cycler starts with a gap t t t t t t t S Function j *- cycler starting with gap t V S Function i - delay on after switched off S delay on after the switch is switched on and delay on after it is switched off S Function h - impulse relay with delay delay on after switching on until it is de-energized or a switch is pressed again. V t t *function j is valid only for SMR-B Time ranges m 10 1 h 1 10 10 S1 m m 1 d 10 0.1 - 1 s ON OFF 10 1 h 1 10 10 1 1 - 10 hrs ON OFF h 1 10 10 S1 m 1 d 10 10 S1 10 1 1 d 10 ON OFF h 1 10 10 S1 1 - 10 s 10 1 10 S1 0.1 - 1 day 1 d 10 ON OFF m 1 d 10 ON OFF h 1 10 m 10 1 h 1 10 10 S1 m 0.1 - 1 min 1 d 10 ON OFF 10 1 10 S1 m 10 1 1 - 10 days h 1 10 1 d 10 ON OFF h 1 10 10 S1 1 d 10 ON OFF m 10 1 1 - 10 min h 1 10 10 S1 m 10 1 only ON 10 S1 1 d 10 ON OFF h 1 10 0.1 - 1 hrs 1 d 10 only OFF ON OFF Connection SMR-B, SMR-H, SMR-T N L n AC 230V Example of SMR-H connectio Function S V V 02 Tehnical data.indd 123 L S V L S V L S N V L S N SMR-T SMR-T SMR-H SMR-H Typical connection of SMR-T - timer for light Fan control depending on light Typical connection of SMR-H - timer fot light Fan control depending on light N S L V SMR- t t Replaces 4 common cross switches Light control in corridor Input for external supply voltage AC/DC 5-250 V 123 9/2/2016 1:43:32 AM Description SMR-T, H SMR-B Exchangeable fuse FUSE 5x20 Output indication Rought time setting Fine time setting Output indication Output neutral switch Output Phase Switch (button) Function setting Neutral (only in SMR-H) function settings Rough time setting FUSE 5x20 Fine time setting Galvanically separated control input 5-250 V AC/DC Phase EVE - ETIREL Technical data Dimension 124 02 Tehnical data.indd 124 9/2/2016 1:43:34 AM EVE - ETIREL Technical data Dimmer flush mounting SMR-S, SMR-U Technical data SMR-S SMR-U 4-wire without neutral 4-wire with neutral AC 230 V / 50-60 Hz max. 3VA - 15%; + 10% Connection Supply voltage Consumption (no operation/make) Supply voltage tolerance Output Resistive load Capacitive load Inductive load Controlling Control Voltage Current Impulse length Operating temperature Operating position Mounting Protection degree Overvoltage category Pollution degree Fuse Output Glow-lamps in control button Dimensions Standards 10-300 VA 10 -150VA x 500 VA* 500 VA* 500 VA* Voltage Ouput brightness Controlling contact KA short press (<0.5s) turns a light on, another short press turns it off . A longer press (>0.5s) causes a gradual regulation of light intensity min-max-min round until the button is released. After releasing a set intensity is kept in memory, further short presses turn the light on/off keeping the set intensity. The intensity can be changed by further long press. After de-energising the relay remembers the set value. AC 230 V 3 mA min. 50 ms/ max. unlimited 0...+50 °C any free of connecting wires IP30 from front panel III 2 F 1.6A/ 250V solid 0,75 mm2, length 90 mm max. 10 pcs. 49x49x13 mm EN 60669-2-1, EN 61010-1 Functions x * When load is above 300 VA it is necessary to ensure sufficient cooling; see instruction manual technical data Dimensions Warning: it cannot be used for fluorescent lights and energy saving lights! SMR-U: It is not allowed to connect together loads of inductive and capacitive type at the same time Connection SMR-S, SMR-U N L V L S V L S N Description SMR-S SMR-S Typical connection of SMR-S - dimmer of lights SMR- U R, L R, L, C Typical connection of SMR-U - dimmer of lights Warning: it cannot be used for fluorescent lights and energy saving lights! SMR-U: It is not allowed to connect together loads of inductive and capacitive type at the same time Exchangeable fuse Indication Output Button control input Phase 02 Tehnical data.indd 125 125 9/2/2016 1:43:35 AM EVE - ETIREL Technical data Twilight switch in IP65 ETS-16b Connection Technical data Voltage Time delay Light level The number and types of contacts Rated current contact Installation Standards Power supply range Max load current (AC-1) Switch ON treshold Switch off treshold Time delay of switch ON or OFF Adjustment range Working temperature Protection class ETS-16b 230 V AC cca 20s 2-50 Lx 1 NO - NO 16A/AC1 on a flat surface EN 61812-1, EN 50081, EN 61000 180 - 240 V AC 50Hz 16 A 10 lux 20 lux cca 20 s cca 2 - 200 lux - 40 0C ... +50 0C IP65 Setting Dimensions 126 02 Tehnical data.indd 126 9/2/2016 1:43:37 AM EVE - ETIREL Technical data Memory and latching relays MR-41, MR-42 Connection Technical data MR-41 Number of functions Supply Supply voltage UNI Consumption UNI Supply voltage 230 Consumption 230 Supply indication Output Supply voltage tolerance Number of contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Voltage Consumption of input Load between A2 ON/OFF Glow-lamps Control terminals Max. capacity of cable control: -without connected glow lamps -with connected glow lamps Impulse length Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards MR-41 MR-41 MR-42 1 2 A1-A2 CRM-91H 12-240 V AC/DC (50-60 Hz AC) CRM-91H CRM-93H CRM-93H AC 0,17-3 VA / DC 0,5 - 1,2 W AC 0,17-12 VA / DC 0,11 - 1,9 W 230 V AC / 50-60 Hz AC max. 12 VA / DC 1,2 W AC max. 12 VA / DC 1,9 W green LED CRM-2H CRM-2H - 15%; + 10% 1xCO 2xCO 16 A / AC1 2x16 A / AC1 4000 VA / AC1, 384 W /DC 4000 VA / AC1, 2x384 W / DC 30 A / <3 s 30 A / <3 s 250 V AC1 / 24 V DC 250 V AC1 / 24 V DC 500 mW 500 mW red LED red LED 3x107 0,7x105 MR-42 MR-42 12-240 V AC/DC Dimensions AC 0,025-0,2 VA / DC0,1-0,7 W (UNI) , AC 0,53 VA (AC 230V) yes MR-41 CRM-4 CRM-4 MR-41 no (UNI) , yes -max. 4 pcs at 1mA (AC 230V) A1 ON/OFF SOU-1SOU-1 MR-42 MR-42 12 nF (UNI), 12nF (230V) 9nF (UNI), glow lamps cannot connected/NO 9nF (230V), max. 4pcs (1pc-1mA) 9nF (UNI), glow lamps cannot connected/NO 9nF (230V), max. 4pcs (1pc-1mA) min. 25 ms/ max. unlimited -20...+55°C -30...+70°C 4 kV (supply - output) any DIN rail EN 60715 IP 40 from frontal panel III 2 2,5 mm2 90x17, 6x64 mm EN 60669-2-2, EN 61010-1 Function 1-MODULE DESIGN 1-module design DIM-2DIM-2 MR-41 MR-42 3-MODULE DESIGN 02 Tehnical data.indd 127 SHT-2 127 9/2/2016 1:43:39 AM EVE - ETIREL Technical data 91H 93H MR-41 Staircase switch with dimming DIM-2 Connection Technical data Supply Supply voltage Consumption Supply voltage tolerance Supply indication Time setting via Time deviation Repeat accuracy Temperature coefficient Controlling T1 Terminals Voltage Power on control input Impulse length Glow-lamps Controlling T2 Terminals Voltage Power control input Impulse length Glow-lamps Output Rated current Resistive load Inductive load Operating temperature Storage temperature Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards A1-A2 230 V AC (50 Hz) CRM-2H max. 5 VA - 15%; + 10% green LED potentiometer 10% mechanical setting 5% set value stability 0,01% / °C / 20 °C Function Controlled via input T1 (button) T1-A1 230 V AC max. 1,5 VA min. 100 ms / max. unlimited yes, max. 5 pcs (at 1 mA) T2-A1 230 V AC max. 0,1 VA min. 100 ms / max. unlimited no MR-42 contactless - triac 2A 10-500 VA 10-250 VA -20...+55 °C -30...+70 °C any DIN rail EN 60715 IP 40 from front panel III 2 2,5 mm2 90x17,6x64 mm EN 60669-2-1, EN 61010-1 Cycle dim-up time is activated by pressing the button; By repressing the button (during the cycle) it is possible to prolong the time of the cycle. Legend: Controlled via input T2 (switch) t1 t2 t3 T1/T2 Output / Brightness: 10-100% Legend: Dim-up time: 1-40 s Time delay: Output 0s-20min / Brightness: 10-100% Dim-down 1-40s Dim-up time: 1-40 s t1 time: Controlling Time delay: 0s-20min t2 contact time: 1-40s t3 Dim-down The cycle is started by activating the switch T1/T2 Controlling contact and breaks on max. adjusted brightness level. After the switch is turned off the switch cycle is complete. SOU-1 Legend: Description Output / Brightness: 10-100% t1 Dim-up time: 1-40 s t2 Time delay: 0s-20min Supply terminals A1 t3 Dim-down time: 1-40s T1/T2 Controlling contact Supply indication Brightness setting t1 - dim-up time setting Output Controlling input for push button Output indication t2 - time delay setting t3 - dim-down time setting Dimensions Supply terminals A2 Controlling input for switch DIM-2 1-module design 1-MODULE DESIGN 128 02 Tehnical data.indd 128 3-MODULE DESIGN SHT-2 9/2/2016 1:43:41 AM EVE - ETIREL Technical data Dimmer DIM-14 Connection Technical data Supply Supply voltage Consumption Supply voltage tolerance Supply indication Indication output Controlling Terminals Control Voltage Power control input Impulse length Glow-lamps in control button Output Rated current Resistive load Inductive load Capacitive load Output indication Operating temperature Storage temperature Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards DIM-14 A1-A2 230 V AC (50 Hz) 1,3 W - 15%; + 10% green LED 6 VA L max. 5 mA Glow-lamps A1 A1 V T 2.5 A V T1-A1 230 V AC 0,3 - 0,6 VA AC min. 80 ms / max. unlimited yes, max. 5 pcs. (at 1 mA) 2 x MOSFET 2A 500 VA* 500 VA* 500 VA* red LED -20...+35 °C -20...+60 °C any DIN rail EN 60715 IP 40 from front panel III 2 2,5 mm2 90x17,6x64 mm EN 60669-2-1, EN 61010-1 DIM-14 T A2 R, L, C A2 T N Functions Supply A1-A2 Output Brightness Controlling input T * When load is above 300 VA it is necessary to ensure sufficient cooling Recommendation for mounting: leave a gap of min. 0,5 module ( approx. 9 mm) on side of the device to ensure better cooling of the device. Description Warning for DIM-14: it is not allowed to connect together loads of inductive and capacitive type at the same time Supply terminal L Button input Supply terminal N 02 Tehnical data.indd 129 Output 129 9/2/2016 1:43:42 AM EVE - ETIREL Technical data Dimmers for LED bulbs and dimmable fluorescent lamps DIM-15 and SMR-M Technical data DIM-15 SMR-M 230V AC / 50-60 Hz AC 230V -15%; +10% max. 1.5VA max. 0.7W green LED Supply voltage Supply voltage tolerance Apparent power Loss power Supply indication Controlling Control terminals Control wire Control voltage Control input power Control impulse length Glow tubes connection Max. amount of glow lamps connected to controlling input Output Contactless Load* Output status indication Other data Operating temperature Storing temperature Operating position Mounting Protection degree x L-S 230V AC AC 230V AC 0.3-0.6 VA min. 80 ms / unlimited Yes 230V - max. 15pcs 230V - max. 10pcs (measured with glow lamp (measured with glow lamp 0.68mA/230VAC) 0.68mA/230VAC) 2 x MOSFET 300W (at cos fi=1) red LED 160W (at cos fi=1) x -20C ... +35C -20C ... +60C any DIN rail EN 60715 free at connection wires IP40 from front panel / IP10 IP30 in standard conditions terminals Overvoltage category III. Pollution level 2 Terminal wires max. 2x2.5; with sleeve x 1x1.5mm2 Dimensions 90 x 17.6 x 64 mm 49 x 49 x 21 mm Weight 57 g 38 g Standards EN 60669-2-1, EN 61010-1 * Due to a large number of light source types, the maximum load depends on the internal construction of dimmable LEDs and ESL bulbs and their power factor cos φ. The power factor of dimmable LEDs and ESL bulbs ranges from cos φ = 0.95 to 0.4. An approximate value of maximum load may be obtained by multiplying the load capacity of the dimmer by the power factor of the connected light source. Connection Light source type setting SMR-M DIM-15 L L N A1 LED bulbs V T 2.5 A recomended fuse T 1.6 A recomended fuse V A2 L N S T N 130 02 Tehnical data.indd 130 9/2/2016 1:43:43 AM EVE - ETIREL Technical data Functions and controlling Supplying Un T >0.5s <0.5s <0.5s >0.5s <0.5s Controlling:: - short button press (<0.5s) turns the light off or on - long press (>0.5s) enables slight regulation of light intensity - setting of minimal luminance is possible only during decreasing of luminance by long button press V min max max V min Devices description Supply voltage L Supply voltage indication Light source type selection Output A1 Minimal luminance setting Output indication DIM - 15 Minimal luminance setting A2 Supply voltage N Minimal luminance setting: LED bulb: - if the light is turned off, short press (<0.5s) switches the light onto last set luminance level Saving fluorescent lamp: - if the light is turned off, short press increases the luminance onto maximal level (saving fluorescent lamps fires up) and then luminance decreases onto set level - setting of minimal luminance by saving fluorescent lamps serves for harmonizing of lowest light intensity prior its unprompted switching off V Additional information - it is possible to dim only LED bulbs equipped with capacitator supplying - it is not possible to dim saving fluorescent lamps without marking: dimmable - an incorrect setting of light source has effect only on dimming range, it means neither dimmer or load get demaged - maximal load is counting with usage of LC filter T Controlling input Light source type selection Supply voltage indication Output to an appliance Switch (button) Phase Neutral 02 Tehnical data.indd 131 131 9/2/2016 1:43:45 AM EVE - ETIREL Technical data 1-MODULE DESIGN Twilight switch SOU-1 + sensor Technical data Supply Supply voltage AC 230 Consumption AC 230 Supply voltage tolerance Supply indication Time dwell Time dwell setting Measuring range 1) Measuring range 2) Output Number of contacts Rated current Breaking capacity CRM-91H Inrush current CRM-93H Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Voltage Consumption of input Load between S-A2 Glow-lamps Terminals Impulse length Reset time Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree SMR-S MR-41 Connection cable length for sensor Overvoltage category Pollution degree Max. cable size Dimensions Standards LE DESIGN IGN SMR-T, SMR-H CRM-4 A1-A2 230 V AC ( 50-60 Hz) max. 12 VA AC / 1,8 W - 15%; + 10% green LED 0-2 min potentiometer 1-100 Lx 100-50000 Lx Connection 1xCO 16/AC1 4000 VA/AC1, 384 W/DC SHT-2 30 A/<3 s 250 V AC1/24 V DC 500 mW red LED 3x107 0,7x105 230 V AC 0,8-530 mVA yes yes, max. 4 pcs (at 1 ms) A1-S min. 25 ms/ max. unlimited 150 ms -20...+55 °C -30...+70 °C 4 kV (supply - output) any DIN rail EN 60715 IP 40 from frontal panel max. 50 m (standard wire) III 2 2,5 mm2 90x17, 6x64 mm EN 60255-6, EN 61010-1 CRM-2H Function ambient light intensity Description of DIP switch Lx LEVEL hysteresis A1-A2 TEST ON S 15-18 t DIP 1 ON DIP 2 ON t 100 - 50000 Lx 1 - 100 Lx TEST ON NORMAL Supply terminals Dimensions MR-42 Terminal of blocking input Sensor for SOU-1 Supply voltage indication Setting of level of illumination Fine setting of level of illumination Terminals for sensor SOU-1 SOU-1 Un h 1 2 Output indication LUX TEST LEVEL [Lx] max min DELAY 0 Switch of test function Setting of output contact delay 2min Output contatcs DIM-2 132 02 Tehnical data.indd 132 9/2/2016 1:43:46 AM Technical data LEVEL hysteresis A1-A2 TEST ON S 15-18 t DIP 1 ON DIP 2 ON t Description EVE - ETIREL Description of DIP switch Lx 100 - 50000 Lx 1 - 100 Lx TEST ON NORMAL Supply terminals Terminals for sensor Terminal of blocking input Supply voltage indication Setting of level of illumination Fine setting of level of illumination SOU-1 Un h 1 2 Output indication LUX TEST LEVEL [Lx] max min DELAY 0 Switch of test function Setting of output contact delay 2min Output contatcs 1-module design 1-MODULE DESIGN 3-MODULE DESIGN 02 Tehnical data.indd 133 SHT-2 133 9/2/2016 1:43:47 AM EVE - ETIREL Technical data Twilight switch with digital time switch SOU-2 + sensor Connection Technical data Supply Supply voltage Consumption Supply voltage tolerance Back-up supply Summer/winter time Output Number of contacts Rated current Breaking capacity Switching voltage Min. breaking capacity DC Mechanical life Electrical life Time circuit Back-up supply Accuracy Minimal interval Data stored for Program circuit Illumination range Program place number Program Data readout Controlling Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards SOU-2 A1-A2 230 V AC (50-60Hz) max. 3,5 VA -15% ; +10% yes automatic external sensor A1 16 A1 T1 T1 16 15 18 18 T1 T1 1 changeover (AgNi) 8 A / AC1 2500 VA / AC1, 240W / DC max. 250 V AC1 / 24 V DC 500 mW 1x107 1x105 3 years max. +/- 1s. day (230C) 1 min. min. 10 years 1-50000 Lx 100 daily, weekly LCD display 15 A2 A2 Controlling elements shows the day of the week mode choice output switching indication of pulse/ cyclic output shows 12/24 h mode winter/summer time indication output ON/OFF random switching mode -20...+55 °C -30...+70 °C 4kV (supply - output) any DIN rail EN 60715 IP 20 from front panel III. 2 2.5 mm2 90 x 35,6 x 64 mm EN 61812-1, EN 61010-1, EN 60255-6 indication of closed output manual switching mode Description external sensor Output - channel 1 (16-15-18) Supply terminal (A1) A1 T1 T1 16 15 18 Display SOU-2 Reset reset reset + ok man esc prg Controlling keys - A2 Supply terminal (A2) 134 02 Tehnical data.indd 134 9/2/2016 1:43:49 AM EVE - ETIREL Technical data Time switch ASTROCLOCK-2 Software class and structure Memory spaces Fluorescent TypesIncandescent of manoeuvres Astronomical adjustment 3000 W 1200 VA Operating temperature Transport and storage temperature Pollution degree Protection level Overvoltage category Transient impulse voltage Keyboard access cover Connection Battery Size 02 Tehnical data.indd 135 Electrical scheme and parameters 230V~ /50-60Hz ± 10% 2 2x 16A / 250 V~ See Electrical scheme and parameters 16 VA (1,3 W) back-lit liquid crystal display ± 1 s / day at 23 ºC ± 0.15 s / ºC / 24 h 10 years (without connection to mains), 48 h (without battery and without connection to mains) Class A 40 Low voltage halogen (12 (230 V AC) SUNRISE,V AC) SUNSET, FIXEDHalogen TIME: ON/ OFF, REDUC. Daily 2000 VA 3000 W -10 ºC ... +45 ºC -20 ºC ... +60 ºC 2 IP 20 (EN60529) Class II under correct mounting conditions 2.5 kV Sealable With screw terminal for section conductors of 4mm² maximum section ½ AA – 3.6 V – 1000 mAh – Li/SOCi2 2 DIN modules (35 mm) Incandescent Fluorescent Low voltage halogen (12 V AC) Halogen (230 V AC) Low consumption lamps Downlights 3000 W 1200 VA 2000 VA 3000 W 600 VA 400 VA Low consumption lamps Downlights LED 600 VA 400 VA 90 VA Dimensions 65 35 60 88 Technical data Rated voltage As indicated in the device Tolerance No. of output contacts Rated current/switching voltage Maximum recommended loads (N.A) Consumption Display Accuracy Temperature effect on accuracy Power reserve 135 9/2/2016 1:43:52 AM EVE - ETIREL Technical data Digital time switch ETICLOCK-R1 Connection Technical data Rated voltage and frequency As indicated on the device Breaking capacity Own consumption Contact Display screen Running accuracy Accuracy variation with temperature Power reserve Memory spaces No. of channels Types of operations Operating temperature Transport and storage temperature Pollution degree Protection level Protection class Transient impulse voltage Temperature for the ball test Keyboard access cover Connection Battery Size ETICLOCK-R1 (230 V~ 50-60Hz) L L µ 1x16 (10) A / 250 V AC 16 VA (1.3 W) max AgSnO2 switched LCD ± 1 s / day at 23 ºC ± 0.15 s / ºC / 24 h 10 years (with battery and no network connection) 48 h (no battery and no network connection) 40 1 ON/OFF, PULSE (1 ... 59 sec.) & CYCLES (1 ... 59 sec. / 1 min ... 23h, 59 min) -10 ºC ... +45 ºC -20 ºC ... +60 ºC 2 IP 20 (EN60529) II under correct mounting conditions 2.5 kV + 80 ºC (21.2.5) Sealable With screw terminal for wire cross section of up to 4mm² ½ AA – 3.6 V – 1000 mAh – Li/ SOCi2 2x DIN mod. (35 mm) ~ 1 2 3 N C1 N Load Controlling elements 1 2 0 3 3 6 9 16 12 15 18 21 24 15 4 12 5 6 7 RESET C1 8 MENU C 10 9 11 1. Time scale 2. Schedules 3. Text line 4. Low-battery symbol 5. Hour / Date 6. C1 manual operation (blinking)/ C1 permanent manual (fixed) 7. C1 relay status symbol 8. Scroll down / C1 manual operation 9. Go up 10. Cancel option / Go back 11. Accept option / Enter the menu / Switch on the device without power 12. 12 H / 24 H 13. Days of the week Dimensions 65 60 35 Maximum recommended loads Load Designation 88 ETICLOCK-R1 3000 W Fluorescent Low voltage halogen (12 V): 1200 VA Halogen (230 V): Low consumption lamps 3000 W 600 VA 400 VA 90 VA Downlights LED Max. load Incandescent 2000 VA 136 02 Tehnical data.indd 136 9/2/2016 1:44:01 AM EVE - ETIREL Technical data Current monitoring relay PRI-51 Connection Technical data PRI-51 Supply circuit Supply Universal supply Consumption Supply voltage tolerance Measuring circuit Load Current ranges Inrush overload <1ms Max. permanent current Time setting Time ranges Setting accuracy - mechanical Time deviation Limit values tolerance Temperature coefficient Hysteresis Output Number of contacts Rated current Breaking capacity Output indication Controlling Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards A1-A2 24-240V AC / 24 V DC (50-60 Hz AC) max 1,5 VA -15% - +10% between B1 - B2 PRI51/1 PRI51/2 PRI51/5 PRI51/8 PRI51/16 AC 0.1- AC 0.2- AC 0.5- AC 0.8- AC 1.61A 2A 5A 8A 16A 100 A 1A 2A 5A 8A 16A potentiometer 0.5 s-10 s. 5% <1% 5% < 0.1 % / °C 5% Example connection: PRI-51 with current transformer for current range increase L N LOAD A1 A2 A1 A2 B1 B2 B1 B2 16 16 15 1 x changeover (AgNi) 8 A / AC1 2500 VA / AC1, 240W / DC green / red LED Functions -20...+55 °C -30...+70 °C 4 kV (supply-output) any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 60255-6, EN 61010-1 Description A1 current transformer 18 15 18 A1 A2 B1 B2 16 18 15 Supply terminals Measuring input (only AC) A2 B1 B2 PRI-51 Un I> Output indication Adjusting current in % In Adjusting time pause 0.5 In-1A 16 15 02 Tehnical data.indd 137 Output contact 18 Output contact 137 9/2/2016 1:44:02 AM EVE - ETIREL Technical data Voltage monitoring relay HRN-33, HRN-34, HRN-35 Symbols Technical data HRN-33, HRN-34, HRN-35 HRN-34 A1-A2 monitoring voltage range max. 1,2 VA AC / DC 18-30 V DC 30-99% Umax 0 -10 s. 5% <1% < 0,1% / °C 2-6 % of adjusted value Type Supply Universal supply Consumption Upper level Umax Bottom level Umin Time delay Setting accuracy (mechanical) Repeat accuracy Temperature coefficient Hysteresis Output Number of contacts HRN-33 A1-A2 monitoring voltage range max. 1,2 VA AC / DC 160-276 V AC 30-99% Umax 0 -10 s. 5% <1% < 0,1% / °C 2-6 % of adjusted value 1 x changeover (AgNi) 1 x changeover (AgNi) Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards 16 A / AC1 4000VA / AC1, 384W / DC 30 / < 3s. max. 250 V AC1 / 24V DC 500mW green / red LED 3x107 0.7x105 16 A / AC1 4000VA / AC1, 384W / DC 30 / < 3s. max. 250 V AC1 / 24V DC 500mW green / red LED 3x107 0.7x105 HRN-33 HRN-35 A1-A2 monitoring voltage range max. 1,2 VA AC / DC 160-276 V AC 30-99% Umax 0 -10 s. 5% <1% < 0,1% / °C 2-6 % of adjusted value HRN-34 16 A1 1 x changeover (AgNi) for each voltage level 16 A / AC1 4000VA / AC1, 384W / DC 30 / < 3s. max. 250 V AC1 / 24V DC 500mW green / red LED 3x107 0.7x105 18 15 A2 18 15 A2 HRN-35 16 A1 -20...+55 °C -30...+70 °C 4 kV any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 60255-6, EN 61010-1 Functions 16 A1 18 15 A2 26 28 25 Connection Un Legend: Umax - upper adjustable level of voltage HRN-33 HRN-33 Un - measured voltage Hysteresis Umin - bottom adjustable level of voltage A1 A2 Un Hysteresis 15-18 - switching contact of output relay No.1 HRN-34 - + 25-28 - switching contact of output relay No. 2 A1 LED ≥ Un - indication green A2 < - indication red LED U> Un HRN-35 15 16 18 A1 HRN-35 HRN-34 A2 15 16 18 Hysteresis Hysteresis Hysteresis Hysteresis 25 26 28 15 16 18 138 02 Tehnical data.indd 138 9/2/2016 1:44:03 AM EVE - ETIREL Technical data Indication LED HRN-33 HRN-34 Normal state Umin<Un<Umax Green LED = ON Red LED = OFF Normal state Umin<Un<Umax Green LED = ON Red LED = OFF Exceeded Umax (overvoltage) Drop below Umin (undervoltage) Un>Umax or Un<Umin. Green LED = ON Red LED = ON Exceeded Umax (overvoltage) Drop below Umin (undervoltage) Un>Umax or Un<Umin. Green LED = OFF Red LED = ON HRN-35 Normal state Umin<Un<Umax Green LED = ON Red LED = OFF Exceeded Umax (overvoltage) Un>Umax Green LED = ON Red LED = ON Drop below Umin (undervoltage) Un<Umin Green LED = OFF Red LED = ON Function description Monitoring relay series HRN-3 monitors level of voltage in single-phase circuits. Monitored voltage serves also as supply voltage. It is possible to set two independent levels of voltage, when exceeded output is activated. HRN-33 and HRN-34 - in normal state the output relay is permanently switched on. It switches off when voltage is below or above deflection. This combination of linkage of the output relay is advantageous when the full failure of supply (monitored) voltage is considered to be a faulty state in the same way as a decrease of voltage within the set level. Output relay is in both situations always switched off. Differently HRN-35 version uses independent relay for each level, in normal state it is switched off . If the upper level is exceeded (for example overvoltage) 1st relay switches on, when the bottom level (e.g. undervoltage) is exceeded 2nd relay switches. It is thus possible to see the particular faulty state. To eliminate short peaks in the main, the time delay, which is possible to be set in range 0 - 10 s, is used. It functions when changing from normal to faulty state and prevents unavailing pulsation of the output relay caused by parasitive peaks. Time delay doesn´t apply when changing from faulty to normal state, but hysteresis (1-6% depends on the voltage setting) apply. Thanks to changeover contacts it is possible to get other configurations and functions according to actual requirements of the application. Description HRN-33, HRN-34 Supply/monitoring voltage A1 A2 Indication HRN-35 Adjusting of upper value Umax Supply/monitoring voltage Adjusting of delay A1 Adjusting of bottom value Umin A2 Indication Adjusting of upper value Umax Adjusting of delay Adjusting of bottom value Umin 15 16 18 Output contact 25 15 02 Tehnical data.indd 139 16 26 18 28 Output contact for Umin Output contact for Umax 139 9/2/2016 1:44:05 AM EVE - ETIREL Technical data Over/undervoltage monitoring relay HRN-54, HRN-54N Connection Technical data Supply and measuring Supply Supply/measured voltage Level Umin Level Umax Consumption Hysteresis Max. permanent overload Peak overvoltage <1ms. Time delayT1 Time delayT2 Output Number of contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Reset time Controlling Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards HRN-54 HRN-54N L1,L2,L3 L1,L2,L3,N L1,L2,L3 L1,N 3 x 400 V 3 x 400 V/ 230 V 75 - 95% Un 105 - 125% Un max. 2 VA 5% 3 x 460V AC 3 x 265V AC 3 x 500V AC 3 x 288V AC max. 500 ms. 0.1 - 10 s. 1 x changeover (AgNi) 8 A / AC1 2500 VA / AC1, 240W / DC 10 A max. 250 V AC1 / 24 V DC 500mW red LED 1x107 1x105 max. 150 ms. HRN-54 HRN-54N L1 L2 L3 16 15 18 15 HRN-54N L1 16 18 L1 U N 18 16 18 U L3 15 L2 L3 15 Functions Hysteresis Umax -20...+55 °C -30...+70 °C 4 kV any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 60255-6, EN 61010-1 N L3 16 HRN-54 L2 L1 L2 Umin Uoff Umax Umin Uoff Umax Umin Uoff Hysteresis 15 - 18 green LED red LED Function description Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independent. In normal state when voltage is within set levels, output relay is closed and red LED shines. In case voltage exceeds or falls below the set levels, output relay breaks and red LED shines (LED indicates faulty state – flashes when timing). In case of In case supply voltage falls below 60 % Un (UOFF lower level) relay immediately breaks without delay and faulty state is indicated by red LED. In case timing is in progress and faulty state is indicated, timing is immediately stopped. Description L1 Supply/monitoring voltage Supply/monitoring voltage supply indication N L2 L3 Output indication Adjusting upper value Umax Adjusting of time delay T2 Adjusting bottom value Umin 16 15 18 Output contact 140 02 Tehnical data.indd 140 9/2/2016 1:44:07 AM Technical data EVE - ETIREL Level switch HRH-1 Connection and symbol Technical data Function: Supply terminals: Supply voltage: Consumption: Supply voltage tolerance: Measuring circuit Hysteresis (input - opening): Voltage on electrode: Current in probes: Time reaction: Max. cable capacity: Time delay tD: Time delay tH: Accuracy Setting accuracy (mech.): Output Number of contacts: Rated current: Breaking capacity: Inrush current: Switching voltage: Min. breaking capacity DC: Mechanical life: Electrical life (AC1): Other information Operating temperature: Storage temperature: Electrical strength: Operating position: Mounting: Protection degree: Overvoltage category: Pollution degree: Max. cable size (mm²) Dimensions: Weight: Standards: 4 A1 - A2 AC/DC 230 V, AC/DC 24 V, AC 110 V, (galvanically separated) max. 4.5 VA -15 %; +10 % in an adjustable range 5 kΩ- 100 kΩ max. 5 V AC <1 mA AC max. 400 ms 4 nF adjustable 0.5 -10 sec adjustable 0.5 -10 sec ±5% 2x changeover (AgNi) 16 A / AC1 4000 VA / AC1, 384 W / DC 30 A / < 3 s 250 V AC1 / 24 V DC 500 mW 3x107 0.7x105 -20 .. +55 0C -30 .. +70 0C 4 kV (supply - output) any DIN rail EN 60715 IP 40 from front panel III. 2 solid wire max.1x 2.5 or 2x1.5/ with cavern max. 1x1.5 90 x 52 x 65 mm 240 g EN 60255-6, EN 61010-1 Un HRH-1 A1 A1 A2 C D H S C D H S 16 18 28 26 Level A2 15 25 16 15 18 28 25 26 Terminals description: A1, A2 - supply voltage C - wire for both probes D - wire of bottom probe E2 H - wire of upper probe E1 S - earth terminal for possible screening of cable 15-16-18 output contact relay 1 25-26-28 output contact relay 2 Description Selection of delay type of input H Selection of delay type of input D Inversion of function of input D Function selection: double/single level relay Indication of supply voltage Output contact 1. relay Adjusting delay input H Output contact 2. relay Adjusting delay input D Adjusting sensitivity of probe according to liquid resistance Measuring probes Measuring probe can be arbitrary (whatever conductive contact, recommended is using of brass or stainless-steel material). Conductor doesn´t need to be screened, but it is recommened . In application of screened conductor is this contacted to terminal S (the earth potential). Function description It is a relay to control levels of conductive liquids (water, chemical solutions, foodstuff . etc.) It means measuring of liquids by measuring probes. AC voltage 5V / 50 Hz is used as a measuring signal. Using this AC signal prevents increased oxidation of probes and undesirable polarization and electrolysis of liquid. It is possible to control two independent levels or to use a combined function for one level control. It depends on DIP switch setting (see also diagram of functions). Relay is equipped by sensitivity regulation that applies to liquid resistance. When the sensitivity is set according to particular conditions it is possible to eliminate some undesirable switching (e.g. pollution of probes, sediments, humidity etc.) It is also possible to set a delay for each probe in range 0.5 - 10 s and by ussing. DIP switch also the type of delay (when the relay is switched on/off , the choice depends on particular application. 02 Tehnical data.indd 141 141 9/2/2016 1:44:08 AM EVE - ETIREL Technical data Level switch HRH-5 Technical data Symbol HRH-5 Functions: Supply terminals: Supply voltage: Input: Tolerance of supply voltage: Measuring circuit Sensitivity ( input resistance): Voltage in electrodes: Current in probes: Time response: Max. capacity of probe cable: Time delay (t): Time delay after switching on (t1): Accuracy Accuracy in setting (mechanical): Output Number of contacts: Rated current: Switched output: Switched voltage: Min. switched output DC: Mechanical life (AC1): Electrical life: Other data Operational temperature: Storing temperature: Electrical strength: Operational position: Mounting: Protection degree: Overvoltage category: Pollution degree: Profile of connecting wires (mm²) Dimensions: Weight: Applicable standards: 2 A1 - A2 24... 240 V AC/ DC max. 2 VA -15 %; +10 % 16 A1 C D H Level 15 A2 adjustable in range 5 kΩ -100 kΩ max. 3.5 V AC <0.1 mA AC max. 400 ms max. 400 ms 800 nF (sensitivity 5kΩ), 100 nF (sensitivity 100 kΩ) adjustable, 0.5 -10 sec 1.5 sec ±5% 18 Supply voltage terminals Terminals for conection of probes H , D Output indication Description A1 A2 D H Indication of supply voltage Choice of function 1x changeover (AgNi) 8 A / AC1 2500 VA , 240 W 250 V AC1 / 24 V DC 500 mW 1x107 1x105 Choice of function Adjustment of delay on output C 16 HRH-5 15 Terminal for connection of probe C 18 Output contacts Connection -20.. +55 0C -30.. +70 0C 3.75 kV (supply - sensors) any DIN rail EN 60715 IP 40 from font panel III. 2 max.1x 4, max.2x2.5/ with sleeve max. 1x2.5, 2x1.5 90 x 17.6 x 64 mm 72 g EN 60255-6, EN 61010-1 Monitoring of two levels Monitoring of one level Un Un A1 A2 A1 A2 H D H D 16 C 16 C 15 18 15 18 max max min Tank with monitored level Tank with monitored level Technical data - Measuring probes HRH HRH-5-measuring probes Functions Function PUMP UP Function PUMP DOWN Un max level min Un max level min t 15-18 red LED t 15-18 t t 10m, 15m, 20m, 30m, 40m 1,5 mm2 750 V Conductible, unaggressive * red LED Relay is designated for monitoring of levels of conductive liquids with possibility of functions: PUMP UP or PUMP DOWN. To prevent polarization and liquid electrolysis of liquid, and undesirable oxidation of measuring probes, alternating current is used. For measuring use three measuring probes: H- upper level, D- lower level, C - common probe. In case you use a tank made of a conductive material, you can use it as probe C. In case you require monitoring of one level only, it is necessary to connect inputs H and D and connect them to one probe - in this case sensitivity is lowered by half (2.5... 50kΩ). Probe C can be connected with a protective wire of supply system (PE). To prevent undesirable switching out output contacts by various influences (sediment on probes, humidity...) it is possible to set sensitivity of the device according to conductivity of monitored liquid (corresponding to “resistance” of liquid) range 5 up to 100...kΩ. To reduce influences of undesirable switching of output contacts by liquid gorgle in tanks, it is possible to set delay of output reaction 0,5 - 10s. Cables Max. cable size Insulation voltage Ui Fluids * Special probes for aggressive fluids 14mm 120mm 142 02 Tehnical data.indd 142 9/2/2016 1:44:12 AM EVE - ETIREL Technical data Thermostat relay TER-3 (A, B, C) Connection Technical data Function Supply Universal supply Consumption Supply voltage tolerance Measuring circuit Measuring terminals Temperature range Hysteresis Sensor Sensor fault indication Setting accuracy - mechanical Switching difference Temperature coefficient Output Number of contacts Rated current Breaking capacity Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards TER-3 (A, B, C) single level A1-A2 AC/DC 24-240 galvanically unseparated 2 VA -15% - +10% A1 18 A2 15 sensor T1 T1 A1 A2 T1 T1 T1 - T1 TER-3A TER-3B TER-3C -30..+10 0C 0..+40 0C -30..+70 0C adjustable in range 0.5...5K external, termistor NTC flashing red LED 5% 0,50C < 0.1 % / °C 1 x changeover (AgNi) 16 A / AC1, 10A/24 V DC 4000 VA / AC1, 300W / DC 250V AC1/ 24V DC 500 mW red LED 3x107 0,7x105 -20...+55 °C -30...+70 °C 4 kV any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 17,6 x 64 mm EN 60730-2-9, EN 61010-1 15 18 Functions TEMPERATURE Hysteresis HEATING COOLING TEST Sensor OFF TER-3 It is a single but practical thermostat with a separated sensor for monitoring temperature. The device is placed in a switchboard and an external sensor senses temperature of required space, object or liquid. Supply is not galvanically separated from the sensor. The sensor is double insulated. Maximal length of a delivered sensor is 12m. device has in-built indication of sensor damage, which means that in case of short-circuit or disconnection red LED flashes. Thanks to adjustable hysteresis , it is advantageous to regulate width of the range and thus define sensitivity of load switching. Sensed temperature is decreased by set hysteresis. When installing it is necessary to keep in mind that hysteresis is increased by temperature gradient between sensor’s jacket and thermistor. Description Supply terminals Sensor terminals Supply voltage indication Heating / cooling selection Output indication Function TEST Temperature adjusting Hysteresis adjusting Output contact 02 Tehnical data.indd 143 143 9/2/2016 1:44:13 AM EVE - ETIREL Technical data Thermostat for monitoring temperature of motor winding TER-7 Technical data Function Supply terminals Supply voltage Consumption Supply voltage tolerance Measuring circuit Measuring terminals Cold sensor resistance Upper level Bottom level: Sensor: Sensor failure indication Accuracy Accuracy in repetition Temperature dependance Output Number of contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Mechanical life Electrical life Other information Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size (mm2) Dimensions Weight Standard Symbol and connection TER-7 monitoring temperature of motor winding A1-A2 24 - 240 V AC/ DC max. 2 VA -15 %; +10 % 16 A1 18 26 28 A1 PTC R 25 26 28 15 A2 25 Ta-Tb 50 Ω - 1.5 kΩ 3.3 kΩ 1.8 kΩ PTC temperature of motor winding blinking red LED < 5% ±5% < 0.1 % / 0C A2 15 16 18 Ta R Tb PTC Function ∞Ω Ω 2x changeover (AgNi) 8 A / AC1 2000 VA / AC1, 192 W / DC 10 A /< 3 s 250 V AC1 / 24 V DC 500mW 3x107 0.7x105 - 20 .. +55 0C - 30 .. +70 0C 4 kV (supply - output) any DIN rail EN 60715 IP 40 III. 2 solid wire max.1x 2.5 or 2x1.5 with sleeve max. 1x2.5 90 x17.6 x 64 mm, 83 g EN 60730-2-9, EN 61010-1 3.3 Ω 1.8 Ω Ω Ω Red LED Memory The device controls temperature of motor winding with PTC thermistor which is mostly placed in motor winding or very close to it. Resistance of PTC thermistor run to max 1.5 kΩ in cold stage. By temperature increase the resistance goes strongly up and by overrun the limit of 3.3 kΩ the contact of output relay switch off - mostly contactor controlling a motor. By temperature decrease and thereby decrease of thermistor resistance under 1.8 kΩ the output contact of relay again switches on. The relay has function “Control of sensor fault“. This controls interruption or disconnection of sensor. When switch is in position “TK” monitoring of faulty sensor is not functional - it is possible to connect bimetal sensor with only 2 states: ON or OFF. The device can work with bi-metal sensor in this position. Other safety unit is function “Memory”. By temperature overrun (and output switches off ) the output is hold in faulty stage until service hit. This bring the relay to normal stage (with RESET button) on front panel or by external contact ( remote). Description Supply terminals 25 Note: Sensors could be in series in abide with conditions in technical specifi cation - switching limit. Output contacts A2 A1 28 26 Faulty states indication Supply voltage indication MEMORY function Function TEST Warning!: In case of supply from the main, neutral wire must be connected to terminal A2. RESET button Ta 15 16 R Tb 18 Output contacts Terminals for sensor and reset 144 02 Tehnical data.indd 144 9/2/2016 1:44:15 AM EVE - ETIREL Technical data Multifunction digital thermostat TER-9 Connection Technical data Number of functions Supply Supply voltage Consumption Supply voltage tolerance Measuring circuit Measuring terminals Temperature range Hysteresis (sensitivity):) Difference temperature Sensor Sensor fault indication Measuring accuracy Repeat accuracy Temperature coefficient Output Number of contacts Rated current Breaking capacity Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life Controlling Operating temperature Storage temperature Electrical strength Operating position Mounting Protection degree Overvoltage category Pollution degree Max. cable size Dimensions Standards TER-9 6 A1-A2 AC 230V or AC/DC 24V, galvanically separated max. 3,5 VA -15% - +10% T1 - T1 in T2-T2 -40...+110 °C adjustable in range 0.5...5K adjustable 1.. 20 °C termistor NTC 12Ω at 25°C sign ''Err'' 5% <0,5 % < 0.1 % / °C 1 x changeover for each output (AgNi) 8 A / AC1 2500 VA / AC1, 240W / DC 250V AC1/ 24V DC 500 mW ON / OFF 1x107 1x105 -20...+55 °C -30...+70 °C 4 kV (supply - contact) any DIN rail EN 60715 IP 40 from front panel III. 2 2.5 mm2 90 x 35,6 x 64 mm EN 60730-2-9, EN 61010-1, EN 61812-1 sensor NTC 1 Output 1 A1 T1 T1 16 15 18 A1 16 18 26 28 T1 T1 T2 T2 TER-9 A2 15 25 A2 T2 T2 26 25 28 Output 2 sensor NTC 2 Note: It is possible to operate the device with one sensor. In such case it is necessary to connect resistor10kΩ. This resistor is a part of delivery. Description Supply terminal (A1) sensor 1 Output 1 (16-15-18) A1 T1 T1 16 15 18 Display T1 0 C Sealable cover Controlling keys TER - 9 reset + ok man prg esc A2 T2 T2 26 25 28 Output 2 (26-25-28) Supply terminal (A2) sensor 2 02 Tehnical data.indd 145 145 9/2/2016 1:44:17 AM EVE - ETIREL Technical data 2 independent single-stage thermostat Function HEATING T1 H1 dy1Ts1 25-28 dy2 dy1 dy2 Function HEATING T2 dy1Ts2 25-28 dy2 H2 dy1 Legend: Ts1 - real (measured) temperature 1 Ts2 - real (measured) temperature 2 T1 - adjusted temperature T1 T2 - adjusted temperature T2 H1 - adjusted hysteresis for T1 H2 - adjusted hysteresis for T2 dy1 - set switching delay of the output dy2 - set delay on output breaking 15-18 output contact (for T1) 25-28 output contact (for T2) Output contact switched until adjusted temperature is reached. Hysteresis eliminates frequent switching. Heating/cooling function adjusted in the menu. Legend: Ts1 - real (measured) temperature 1 Ts2 - real (measured) temperature 2 T1 - adjusted temperature T1 T2 - adjusted temperature T2 H1 - adjusted hysteresis for T1 H2 - adjusted hysteresis for T2 dy1- set switching delay of the output dy2 - set delay on output breaking 25-28 output contact (for T2) 15-18 output contact (intersection T1 and T2) Output 15-18 is closed, if temperature of both thermostats is bellow an adjusted level. When any thermostat reaches adjusted level, the contact 15-18 open. Serial inner connection of thermostats (logic function AND). Legend: Ts1 - real (measured) temperature T1 Ts2 - real (measured) temperature T2 D - adjusted difference dy1- set switching delay of the output dy2 - set delay on output breaking 15-18 output contact (for T1) 25-28 output contact (for T2) Switching of output corresponds with input, which has lower temperature when difference is exceeded differential thermostat is used for keeping two identical temperature e.g. in heating systems (boiler and reservoir), solar systems ( collector reservoir, exchanger), water heating ( water heater, water distribution) etc. Legend: Ts - real (measured) temperature T1 - adjusted temperature D - adjusted diff erence H1 - adjusted hysteresis for T1 H2 - adjusted hysteresis for T2 dy1- set switching delay of the output dy2 - set delay on output breaking 15-18 output contact 25-28 output contact Typical example of use for two-stage thermostat is e.g in boiler-room, where there are two boilers from which one is main and the other one is auxiliary. The main boiler is managed according to set temperature and auxiliary boiler is switched in case temperature falls under set difference. Thus it helps to the main boiler in case outside temperature dramatically falls. In the range of difference (D) output 15-18 functions as normal thermostat to input 1 ( type 1). In case temperature falls under set difference, output 2 switches. Legend: Ts - real (measured) temperature T1 - adjusted temperature MAX T2 - adjusted temperature MIN (T2=T1-D) H1 - adjusted hysteresis for T1 H2 - adjusted hysteresis for T2 dy1- set switching delay of the output dy2 - set delay on output breaking 15-18 output contact 25-28 output contact Output is closed (heating) only if temperature is within adjusted range. If temperature is out of range, the contact opens. T2 is set as T1-D. The function is used for protection of gutters against freezing. Legend: Ts - real (measured) temperature T1 - adjusted temperature T1 T2- adjusted temperature T2 (T2=T1-D) H1 - adjusted hysteresis for T1 H2 - adjusted hysteresis for T2 dy1- set switching delay of the output dy2 - set delay on output breaking 15-18 output contact (heating) 25-28 output contact (cooling) In case of thermostat with a „dead zone“ , it is possible to set temperature T1 and a difference (respectively a width of dead zone D). In case the temperature with set hysteresis H1 is lower than T1, the output contact switches heating ON and when T1 is reached it opens. In case the temperature falls under T2, contact switches cools down and opens when T2 is reached. This function can be used for example for automatic air warming and cooling in ventilation so the sit is always within the range T1 and T2. dy2 Dependent functions of 2 thermostats H2 Ts2 T2 dy2 dy1 dy2 dy1 25-28 H1 Ts1 T1 dy1 dy2 15-18 dy2 dy1 dy1 dy2 dy1 dy1 dy2 15-18 Differential thermostat Ts1 D-H1 D D-H2 D Ts2 D dy2 dy1 dy1 dy2 dy1 2-stage thermostat H1 T1 Ts D H2 dy1 dy2 dy2 dy1 dy1 dy2 15-18 dy1dy2 dy1 25-28 Thermostat with “WINDOW” T1 H1 Ts D H2 T2 dy1 dy2 dy1 dy2 dy1 dy2 dy1 dy2 dy1 dy2 dy1 dy2 15-18 25-28 Thermostat with dead zone H1 T1 Ts D H2 T2 dy1 dy2 15-18 dy1 dy2 dy1 25-28 146 02 Tehnical data.indd 146 9/2/2016 1:44:19 AM EVE - ETIREL Technical data Thermal sensor TZ Temperature sensors are made of thermistor NTC embedded in a metal sleeve by thermo-conductive sealer (TZ) Sensor TZ : - cable V03SS-F 2Dx0,5mm with silicon insulation - suitable mainly for use in extreme temperatures Technical parameters TZ Range: Scanning element: In air/in water: In air/in water: Cable material: Terminal material: Protection degree: Protection class: -40...+125°C NTC 12K 2% (t65) 62s/8s (t95) 216s/23s silicone nickel-couted copper IP 67 II (double insulation) Resistive values of sensors in dependance on temperature Temperature (°C) Sensor NTC (kΩ) 20 14,7 30 9,8 40 6,6 50 4,6 60 3,2 70 2,3 TZ: Thermal sensors for range -40...+125° TZ-0 - Thermo sensor can be connected directly to terminal block (length of the sensor 110mm) TZ-3 - Temperature sensor 3m, double isolation silicone TZ-6 - Temperature sensor 6m, double isolation silicone TZ-12 - Temperature sensor 12m, double isolation silicone Dimensions 1-module devices 02 Tehnical data.indd 147 2-module devices 147 9/2/2016 1:44:20 AM EVE - ETIREL Technical data Product loadability It is valid for following products: CRM-4, SHT-1, MR-41, MR-42, SOU-1, SHT-1/2, SHT-3, SHT-3/2, CRM-42, SMR-B Load relay contact 16 A AgSNO2 2000 W 1000 W 1000 W 750 W 500 W AC1 AC3 AC15 DC1 (24/110/220 V) 4000 VA 0,9 kW 750 VA 16A/0,5A/0,35A AC3 AC15 DC1 (24/110/220 V) 375 VA 8A/0,4A/0,25A It is valid for following products: CRM-93H, SOU-2, HRN-54, HRN-54N, PRI-51, TER-9 Load relay contact 8A AgNi AC1 500 W x x x x 2000 VA It is valid for following products: CRM-91H, CRM-2H, CRM-2T, HRN-33, HRN-34, HRN-35, TER-3 Load relay contact 16 A AgNi 1000 W x x x x AC1 AC3 AC15 DC1 (24/110/220 V) 4000 VA 0,9 kW 750 VA 16A/0,5A/0,35A Hour meter HM-1 Technical data Mechanical data Display Digit height Counting range Reading accuracy Weight Electrical data Operating voltage Current consumption Accuracy IP protection Ambient conditions Operating temperature Storage temperature Relative humidity Approvals description 5 integers, 2 decimals 4mm 99999,99 1/100 h (36sec) 32g Dimensions 230V+/- 10%, 50Hz Max. 8mA +/- 0,02% IP40 -25oC .. + 70oC -40oC .. + 70oC Max. 80% / +25oC CE Mark RoHS compliant 148 02 Tehnical data.indd 148 9/2/2016 1:44:25 AM EVE - ETIREL Technical data Pulse counter PC-1 Technical data Mechanical data Counting Display Digit height Operating life Weight Electrical data Operating voltage Power consumption Pulse duration Pulse interval Max. counting speed Cycle duration factor Connection IP protection Ambient conditions Operating temperature Storage temperature Relative humidity Approvals description adding without reset 6 digit 4mm 2 x 106 pulses 60g 230V+/- 10%, 50Hz 4W 50ms 50ms 10 pulses/sec 100% (max. 20 sec at 230V AC) Wire leads ca. 120 mm IP31 -100C .. + 550C -200C .. + 700C Max. 80% / +250C CE Mark RoHS compliant Dimensions 02 Tehnical data.indd 149 149 9/2/2016 1:44:26 AM EVE - ETIREL Technical data Power supplies PS-30 Technical data PS-30-12 Input Voltage range Burden without load (max) Burden with full load (max) Protection Output Output voltage DC / max. current Tolerance of output voltage: Output indication Wave of off-load output voltage Wave of output voltage with max load Time delay after connection Time delay after over-load Efficiency Electronic fuse PS-30-24 AC 100-250V / 50 - 60Hz 9VA / 1W 10VA/1.5W 70VA / 37W fuse T2A 12.2V/2.5A 24.2V/1.25A PS-30: switching stabilized power supplies, version 3-module PS-30-12 - stabilized power supply with fixed output voltage 12 V/30 W PS-30-24 - stabilized power supply with fixed output voltage 24 V/30 W Connection AC 100 - 250 V 50 Hz/ 60 Hz N L ± 2% green LED 30mV 80mV max. 5s max. 1s >82% electronic protections short-circuit, over load, over voltage (from 120% of rated output) Other information Working humidity Operating temperature Storage temperature Electrical strength input- output Protection degree AC DC + - 20 .. 90% RH -20 °C ... +40 °C -25 °C ... +70 °C 4kV IP40 device/ IP20 in-built in distribution board II. 2 solid wire max.1x2.5 or 2x1.5/ with sleeve max.1x1.5 90 x 52 x 65 mm 158 g EN 61204-1, EN 61204-3, EN 61204-7 Overvoltage category: Pollution degree Max. cable size (mm2) Dimensions Weight Standards Description PS-30-12, PS-30-24 Supply terminals N L Output voltage indication Output voltage terminals + + + \ - - - Output voltage terminals 150 02 Tehnical data.indd 150 9/2/2016 1:44:27 AM EVE - ETIREL Technical data Wireless Wall Switch Button BU-WS2, BU-WS4 Technical data Type Supply voltage Transmission indication Number of buttons Transmitter frequency Signal transmission method Range in free space Operating temperature Operating position Mounting Protection Contamination degree Dimensions Frame - plastic Frame - metal, glass, wood, granite Weight* Related standards BU-WS2 BU-WS4 3V CR 2032 battery red LED 2 4 868 MHz unidirectionally addressed message ≤ 200 m -10 ...+50 °C any glue / screws IP 20 2 85 x 85 x 16 mm 94 x 94 x 16 mm 38g 39g EN 60669, EN 300 220, EN 301 489 *including standardly delivered plastic frame. No installation into multi-frames. Description BU-WS2 Transmitter indication Control buttons BU-WS4 Transmitter indication Control buttons On wall 02 Tehnical data.indd 151 On wood On glass 151 9/2/2016 1:44:29 AM EVE - ETIREL Technical data Switching Actuator BU-SU, BU-SU Multi Technical data Type Supply voltage Apparent input Dissipated power Supply voltage tolerance Output Number of contacts Rated current Switching power Peak current Switching voltage Max. DC switching power Mechanical service life Electrical service life (AC1) Control RF, by command from transmitter Manual control Range in free space Other data Operating temperature Operating position Mounting Protection Overvoltage category Contamination degree Terminals (CY wire, cross-section) Length of terminals Dimensions Weight Related standards BU-SU Description BU-SU Multi 230 V AC / 50 - 60 Hz 7 VA / cos φ = 0.1 0.7 W +10 %; -15 % 1x switching (AgSnO2) 16 A / AC1 4000 VA / AC1, 384 W / DC 30 A / <3 s 250 V AC1 / 24 V DC 500 mW 3x107 0.7x105 BU-SU Indication of operating and programming mode Program button (ON/OFF manual control) Neutral conductor Phase conductor Output relay contacts 868 MHz PROG (ON/OFF) button up to 200 m Wiring L N -15 ... + 50 °C any * free at lead-in wires IP 30 III. 2 2x 0.75 mm2 , 2x 2.5 mm2 90 mm 49 x 49 x 21 mm 46 g EN 60669, EN 300 220, EN 301 489 L N BU-SU BU-SU Multi BU-SU BU-SU Multi Functions and their programming - BU-SU Multi Button Press 1x rogram mode The output contact will close by pressing the button and open by releasing the button. Switch On rogram mode The output contact will close by pressing the button. Press 4x The output contact will switch to the opposite position with each press of the button. If the contact was closed, it will open and vice versa. rogram mode rogram mode Press 5x The output contact will close by pressing the button and open after the set time interval has elapsed. Press 3x The output contact will open be pressing the button. Delayed return Impulse relay rogram mode Press 2x Switch Off Delayed start rogram mode Press 6x The output contact will open by pressing the button and close after the set time interval has elapsed. 152 02 Tehnical data.indd 152 9/2/2016 1:45:06 AM EVE - ETIREL Technical data Dimming Actuator BU-DU, BU-DU Multi Technical data Type Supply voltage Apparent input Dissipated power Supply voltage tolerance Connection Output Resistance load Capacity load Inductive load Control RF, by command from transmitter Manual control Range in free space Other data Operating temperature Operating position Mounting Protection Overvoltage category Contamination degree Terminals (CY wire, cross-section) Length of terminals Dimensions Weight Related standards BU-DU BU-DU Multi 230 V AC / 50 Hz 8.3 VA / cos φ = 0.1 0.83 W +10/ -15 % 3 conductors, including neutral 250 VA* 250 VA* 250 VA* 868 MHz PROG (ON/OFF) up to 160 m -15 ... + 50 °C any free at lead-in wires IP 30 III. 2 3x0.75 mm2 90 mm 49 x 49 x 21 mm 40 g EN 60669, EN 300 220, EN 301 489 Wiring with different types of load L N L N Description N Device status indicator Program button (ON/OFF manual control) L N V L V RLC RLC RFDA-11B RFDA-71B RFDA-11B RFDA-71B L-Induction R-Resistance Neutral conductor L N Output to appliance Phase conductor N L V RLC RFDA-11B RFDA-71B C-Capacity 02 Tehnical data.indd 153 153 9/2/2016 1:45:45 AM EVE - ETIREL Technical data Function 1 - press 1x <0.5s >0.5s <0.5s Function 2 - press 2x >0.5s<0.5s <0.5s >0.5s <3s >3s <3s <0.5s <3s <3s 3s a b c a) Press the button for less than 0.5 seconds to switch on the light; press again to switch it off. b) Press and hold the button for more than 0.5 seconds to adjust brightness continuously. After releasing the button, the brightness level is saved into memory and pressing the button shortly later will switch on/off the light to this intensity. c) Brightness may be adjusted at any time by pressing and holding the button. The receiver remembers the adjusted value even after disconnecting from power supply. a t=3s a <0.5s >0.5s t=3s <0.5s <0.5s <0.5s a <0.5s t=2s..30min >0.5s >0.5s<0.5s <0.5s >0.5s <0.5s t=3s b c a) Press the button for less than 0.5 second to switch on the light,. By pressing the button shortly again, the light will continuously switch off for 3 seconds (at 100% brightness). b) Press and hold the button for more than 0.5 second to adjust brightness continuously. After releasing the button, the brightness level is saved into memory and pressing the button shortly later will switch on/off the light to this intensity. c) Brightness may be adjusted at any time by pressing and holding the button. The receiver remembers the adjusted value even after disconnecting from power supply. Sunset - press 6x <0.5s After pressing the button, the light will start to switch on during the selected time period, ranging from 2 seconds to 30 minutes. c t=3s t=3s c a) Press the button for less than 0.5 seconds to continuously switch on the light for 3 seconds (at 100% brightness). By pressing the button shortly again, the light will continuously switch off for 3 seconds. b) Press and hold the button for more than 0.5 seconds to adjust brightness continuously. After releasing the button, the brightness level is saved in the memory and pressing the button shortly later will switch on/off the light to this intensity. c) Brightness may be adjusted at any time by pressing and holding the button. The receiver remembers the adjusted value even after disconnecting from power supply. Sunrise - press 5x 3s b Function 4 - press 4x >0.5s<0.5s <0.5s >0.5s b <3s a) Press the button for less than 3 seconds to switch on the light; press again to switch it off. b) To avoid undesirable brightness adjustment, the continuous brightness regulation is only activated pressing and holding the button for more than 3 seconds. After releasing the button, the brightness level is saved in the memory and pressing the button shortly later will switch on/off the light to this intensity. c) Brightness may be adjusted by pressing and holding the button for more than 3 seconds at any time. The receiver remembers the adjusted value even after disconnecting from power supply. Function 3 - press 3x <0.5s >3s ON/OFF - press 7x <0.5s <0.5s <0.5s <0.5s >0.5s >0.5s <0.5s t=2s..30min After pressing the button, the light will start to switch off during the selected time period, ranging from 2 seconds to 30 minutes. If the light is off, press the button to switch it on. If the light is on, press the button to switch it off. Dimming Actuator for LED and Dimmable Energy-saving Light Bulbs BU-DEU Examples of connection N L 154 02 Tehnical data.indd 154 9/2/2016 1:45:56 AM Technical data Supply voltage Apparent input Dissipated power Supply voltage tolerance Connection Dimmed load Output Contactless Load capacity Control RF, by command from transmitter Manual control EVE - ETIREL Technical data 230 V AC / 50 Hz 7 VA 0.83 W +10/ -15 % 4 conductors, including “NEUTRAL” LED, ESL Description Potentiometer to set minimum brightness Potentiometer to select the light source 2 x MOSFET 160 W (-> cos φ=1)* 868 MHz PROG (ON/OFF) button), external button up to 160 m Range in free space Other data -20 ... +35 °C Operating temperature -30 ... +70 °C Storage temperature Operating position any Mounting free at lead-in wires Protection IP30 at normal conditions III. Overvoltage category 2 Contamination degree 4 x 0.75 mm2 Terminals (CY wire, cross-section) 90 mm Length of terminals 49 x 49 x 21 mm Dimensions 40 g Weight EN 607 30-1 ED.2 Related standards Installation recommendation: ensure sufficient cooling of the device. * Due to a large number of light source types, the maximum load depends on the internal construction of dimmable LEDs and ESL bulbs and their power factor cos φ. The power factor of dimmable LEDs and ESL bulbs ranges from cos φ = 0.95 to 0.4. An approximate value of maximum load may be obtained by multiplying the load capacity of the dimmer by the power factor of the connected light source. Prog button Output to appliance Phase conductor Button Neutral conductor Wiring L N T 1.6 A stabilizer protection is recommended V L N S Function description 6 light functions (identical to BU-DEU functions) Control with the added button: press the button shortly (<0.5 s ) to switch the light on/off press and hold the button (>0.5 s) to regulate the intensity of light continuously Additional information dimming is only possible for LED lamps equipped with condenser power supply dimming is not possible for energy-saving fluorescent tubes not designated as dimmable an incorrect setting of the type of light source will only affect the dimming range, i.e. will not cause damage to the dimmer or the load the maximum number of dimmable light sources depends on their internal construction maximum load capacity is calculated using a LC filter - DIM-15F setting a minimum brightness is only possible when decreasing brightness by pressing and holding the button Setting minimum brightness: “LED lamp” : if the light is off, press the button shortly (< 0.5s) to turn on the light onto last set intensity level „Energy-saving fluorescent tube“ : if the light is off, press the button shortly to turn on the light onto max. intensity level (fluorescent tube will „light up“) and then intensity decreases onto set level. setting of minimum light intensity by energy-saving fluorescent tubes serves for adjusting the lowest luminance before automatic turning off 02 Tehnical data.indd 155 155 9/2/2016 1:45:58 AM Twilight light switch BU-DUSK1 2x1.5 batteries AAA around 2 years (based on number of controlled units) Setting light level range Function (twilight switch) 1 ... 10 lx - range 1: 10 ... 100 lx - range 2: 100 ... 1.000 lx - range 3: Function (light switch) 100 ... 1 000 lx - range 1: 1 000 ... 10 000 lx - range 2: 10 000 ... 100 000 lx - range 3: Setting functions: rotating switch Fine-tuned lighting level: 0.1 ... 1 x range Fine-tuned setting of lighting level: potentiometer 0 / 1 min. / 2 min. Time delay t: Delay setting t: rotating switch Output 868 MHz Sending communication RF packet: Range in the open: up to 160 m Further data -20.. +50°C* Working temperature: -30 .. +70°C Storage temperature: Working position: sensor down and to sides IP65 Degree of protection: 2 Pollution degree: 72 x 62 x 34 mm Dimensions: 104 g Weight EN 60730-1, EN 300 220, EN 301 489 Relating standards: *Note pay attention to the working temperature of the batteries Description Hole Otvorforzawall zidnuassembly montažu Ø 4.3mm + Batteries Baterije 2x AAA 1.5 V MINM NM AX PROG - 1-10 3 2 1 4 5 6 7 Fino podešavanje Fine-tuning light svetlosti intensity intenziteta lighting within range osvetljenje u dometu Range selection (Lx),(Lx), selection Izbor opsega izbor light / twilight switch svetlosne/noćne sklopke Range + Technical data Power Battery life - EVE - ETIREL Technical data 8 9 Function Selection of function with RF Izbor funkcije sa RF repetitora unit. signalRFrepeater, signala, dodir RF touch Holezafor wall Otvor zidnu assemblyØ Ø 4.3mm 4.3mm montažu Ambient light sensor Spoljni svetlosni senzor Function True level lighting Set the light level Rigid hysteresis ± 6% from set value Function Twilight switch Function Light switch t t t t t on Twilight BU-SU Multi 0 or 100% BU-DU Multi 0 or 100% Light BU-SU Multi BU-DU Multi 156 02 Tehnical data.indd 156 9/2/2016 1:46:00 AM EVE - ETIREL Technical data Bistable Switch RBS RBS220, RBS225, RBS232 44 35 90 35.2 45 90 45 60 RBS420, RBSI425, RBS432 17.6 5 90 02 Tehnical data.indd 157 ° 15° 90 ° 15° 157 9/2/2016 1:46:01 AM EVE - ETIREL Technical data Technical data Type Standards Manual control Control with impulse voltage Indication Protection degree accordance to IEC/EN 60529 Module width Ambient temperature Storage temperature Max. resistance to humidity Min. contact reliability Max. shock resistance accordance to IEC/EN 60068-2-27 Max. vibration resistance accordance to IEC/EN 60068-2-6 Min. distance of open contacts Distance between contacts and coil Mechanical endurance Max. back-up fuse for short-circuit protection (gL) Power dissipation per pole Rated control voltages Rated frequency of control voltage Range of control voltage Coil consumption − inrush Coil consumption − hold Min. impulse duration at Uc Min. impulse duration at 0,85 Uc Min. duration between two impulses Max. number of impulses per minute Max. impulse duration at Uc Rated impulse voltage Thermal current Rated insulation voltage Rated operational voltage Rated frequency Rated operational current for cosφ = 0,6 acc. to IEC/EN 60669-2-2 Rated operational current for AC-1 acc. to IEC/EN 60947-4-1 Rated operational current for AC-7a acc. to IEC/EN 61095 − Slightly inductive loads in hausehold appliances and similar applications Rated operational current for AC-21 acc. to IEC/EN 60947-3 − Switching of resistive loads including moderate overloads Rated operational current for AC-22 acc. to IEC/EN 60947-3 Switching of mixed resistive and inductive loads, including moderate overloads Rated operational current for AC-23 acc. to IEC/EN 60947-3 Switching of motor loads or other highly inductive loads RBS220 RBS232 RBS420 IEC/EN 60669-2-2 With actuator IP 20 RBS425 1 °C °C g g mm mm cycles Uc fc Uc A W V Hz % VA/W VA/W ms ms ms 20 1,5 25 2 BI432 2 -25…+55 -30…+80 95 % RH at +55 °C 10 V / 100 mA 15 3 >3 >6 106 32 20 3 1,5 AC: 24, 230, other on request 25 2 32 3 50 / 60 90…110 18 / 13 9/4 50 100 150 15 7,5 15 7,5 1 hour Uimp Ith Ui Ue fe Ie Ie Ie kV A V V Hz A A A Ie A Ie A Ie A 4 20 25 25 32 25 / 440 V 25 / 440 V 20 440 440 50 / 60 32 / 440 V 20 / 440 V 32 / 440 V 20 / 440 V 20 / 440 V 20 / 440 V 25 / 440 V 25 / 440 V 32 / 440 V 32 / 440 V 20 / 440 V 25 / 440 V 32 / 440 V 20 / 440 V 25 / 440 V 32 / 440 V 20 / 440 V 25 / 440 V 32 / 440 V 20 / 440 V 25 / 440 V 32 / 440 V 20 / 230 V 25 / 230 V 32 / 230 V 20 / 230 V 25 / 230 V 32 / 230 V 16 / 440 V 20 / 440 V 25 / 440 V 16 / 440 V 20 / 440 V 25 / 440 V 25 / 230 V / 1-phase 16 / 230 V / 1-phase 16 / 230 V / 3-phase 16 / 400 V / 3-phase 20 / 230 V / 1-phase 20 / 230 V / 3-phase 20 / 400 V / 3-phase 25 / 230 V / 1-phase 25 / 230 V / 3-phase 25 / 400 V / 3-phase 16 / 230 V / 1-phase RBS225 20 / 230 V / 1-phase 32 158 02 Tehnical data.indd 158 9/2/2016 1:46:02 AM Technical data Type Rated operational current for AC-3 acc. to IEC/EN 60947-4-1 Squirrel-cage motors: starting, switching off motors during running Rated operational current for AC-7b acc. to IEC/EN 61095 Motorloads for household applications Rated operational current for AC-6a acc. to IEC/EN 60947-4-1 Switching of transformers having inrush current peaks of not more than 30 times peak of rated current Rated operational current for AC-6b acc. to IEC/EN 60947-4-1 − Switching of capacitor banks Rated operational current for DC-1 acc. to IEC/EN 60947-4-1 − Non-inductive or slightly inductive loads, resistance furnances Rated operational current for DC-3 acc. to IEC/EN 60947-4-1 − Shunt-motors: starting, plugging, inching Rated operational current for DC-5 acc. to IEC/EN 60947-4-1 − Series-motors: starting, plugging, inching Rated operational current for DC-21 acc. to IEC/EN 60947-3 − Switching of resistive loads including moderate overloads Rated operational current for DC-22 acc. to IEC/EN 60947-3 − Switching of mixed resistive and inductive loads, including moderate overloads Rated operational current for DC-23 acc. to IEC/EN 60947-3 − Switching of highly inductive loads (e.g. series motors) Rated operational current for AC-5a acc. to IEC/EN 60947-4-1 − Switching of electric discharge lamp controls Rated operational current for AC-5b acc. to IEC/EN 60947-4-1 − Switching of incandescent lamps Rated operational current for fluorescent lamps acc. to IEC/EN 60669-2-2 Fluorescent / energy saving / compact lamps with electronic control gear Electrical endurance for all utilization categories Terminal capacity for main circuit Screw for main circuit Screw-head for main circuit Tightening torque for main circuit Terminal capacity for control circuit Screw for control circuit Screw-head for control circuit Tightening torque for control circuit 02 Tehnical data.indd 159 EVE - ETIREL Technical data Ie Ie Ie RBS220 RBS225 RBS232 4,5 / 230 V RBS420 7 / 230 V / 1-phase 6,3 / 230 V / 3-phase 6,6 / 400 V / 3-phase 7 / 230 V / 1-phase 6,3 / 230 V / 3-phase 6,6 / 400 V / 3-phase 3 / 230 V RBS425 8 / 230 V / 1-phase 8,7 V / 230 V / 3-phase 8,5 / 400 V / 3-phase 8 / 230 V / 1-phase 8,7 V / 230 V / 3-phase 8,5 / 400 V / 3-phase 3,6 / 230 V BI432 10 / 230 V / 1-phase 11,5 / 230 V / 3-phase 11,3 / 400 V / 3-phase 10 / 230 V / 1-phase 11,5 / 230 V / 3-phase 11,3 / 400 V / 3-phase 4,5 / 230 V 7 / 230 V / 1-phase 8 / 230 V / 1-phase 10 / 230 V / 1-phase 7 / 230 V / 1-phase 8 / 230 V / 1-phase 10 / 230 V / 1-phase 3 / 230 V 3,6 / 230 V 1,5 / 400 V 1,8 / 400 V 2,2 / 400 V 1,5 / 400 V 1,8 / 400 V 2,2 / 400 V A A A C μF Ie A Ie A Ie A Ie A Ie A Ie A Ie A Ie A Ie A Ie A S cycles mm2 S Nm mm2 Nm 100 μF / 230 V 20 / 24 V / 1 pole 10 / 24 V / 1 pole 10 / 24 V / 1 pole 20 / 24 V / 1 pole 25 / 24 V / 1 pole 15 / 24 V / 1 pole 16 / 24 V / 1 pole 25 / 24 V / 1 pole 32 / 24 V / 1 pole 25 / 24 V / 1 pole 20 / 24 V / 1 pole 32 / 24 / V 1 pole 20 / 24 V / 1 pole 10 / 24 V / 1 pole 10 / 24 V / 1 pole 20 / 24 V / 1 pole 25 / 24 V / 1 pole 15 / 24 V / 1 pole 16 / 24 V / 1 pole 25 / 24 V / 1 pole 32 / 24 V / 1 pole 25 / 24 V / 1 pole 20 / 24 V / 1 pole 32 / 24 / V 1 pole 16 / 24 V / 1 pole 20 / 24 V / 1 pole 25 / 24 V / 1 pole 16 / 24 V / 1 pole 20 / 24 V / 1 pole 25 / 24 V / 1 pole 10 / 24 V / 1 pole 16 / 24 V / 1 pole 20 / 24 V / 1 pole 10 / 24 V / 1 pole 16 / 24 V / 1 pole 20 / 24 V / 1 pole 16 / 230 V 10 / 230 V 16 / 230 V 2 / 230 V 105 1…10 rigid / flexible M4 (±) PZ2 1,2 1…4 rigid / flexible M3 (±) PZ1 0,6 159 9/2/2016 1:46:03 AM EVE - ETIREL Technical data Industrial plugin electromagnetic relays Relays for general application For plug-in sockets: 35 mm rail mount acc. to EN 60715; panel mounting Miniature dimensions Cadmium - free contacts AC and DC coils Recognitions, certifications, directives: RoHS, CE Standards: EN61810-1:2008 (electromechanical relays); EN61984:2002, EN60998-2-1:2001, EN60664-1:2003 (sockets) Table 1: Technical data Number and type of contacts Contact material Rated / max. switching voltage AC Min. switching voltage Rated load (capacity) AC1 AC15 AC3 DC1 DC13 Min. switching current Max. inrush current Rated current Max. breaking capacity AC1 Min. breaking capacity Contact resistance Max. operating frequency (cycles/hour) • at rated load AC1 • no load Coil data Rated voltage 50/60 Hz AC DC Must release voltage Operating range of supply voltage AC Rated power consumption DC Insulation according to EN 60664-1 Insulation rated voltage Rated surge voltage Overvoltage category Insulation pollution degree Dielectric strength • between coil and contacts • contact clearance • pole - pole Contact - coil distance • clearance • creepage General data Operating / release time (typical values) Electrical life • resistive AC1 • cosΦ Mechanical life (cycles) Dimensions (L x W x H) Weight Ambient temperature • storage • operating Cover protection category Environmental protection Shock resistance (NO/NC) Vibration resistance ERM2 2 CO ERM4 4 CO AgNi 250 V / 440 V 10 V 250 V / 250 V 10 V AgNi, 10 V AgNi/Au 0,2 µm, 5 V AgNi/Au 5 µm 12 A / 250 V AC 3 A / 120 V 1,5 A / 240 V 370 W (single-phase motor) 12 A / 24 V DC (see Fig. 3) 0,22 A / 120 V 0,1 A / 250 V 6 A / 250 V AC 1,5 A / 120 V 0,75 A / 240 V (C300) 125 W (single-phase motor) 6 A / 24 V DC (see Fig. 3) 0,22 A / 120 V 0,1 A / 250 V (R300) 5 mA 24 A 12 A 3 000 VA 0,3 W 12 A 6A 1 500 VA 0,3 W AgNi, 0,3 W AgNi/Au 0,2 µm, 0,1 W AgNi/ Au 5 µm ≤ 100 mΩ 1 200 18 000 See table 2 AC: ≥ 0,2 Un DC: ≥ 0,1 Un see Table 2 1,6 VA 0,9 W 250 V AC 4 000 V 1,2 / 50 µs III 3 2 500 V 1,2 / 50 µs II 2 2 500 V AC type of insulation: basic 1 500 V AC type of clearance: micro-disconnection 2 500 V AC type of insulation: basic ≥ 2,5 mm ≥ 4 mm ≥ 1,6 mm ≥ 3,2 mm AC: 10 ms / 8 ms > 105 DC: 13 ms / 3 ms 12 A, 250 V AC see Fig. 2 > 105 6 A, 250 V AC see Fig. 2 > 2 x 107 27,5 x 21,2 x 35,6 mm 35 g -40...+85 oC DC: -40...+70 oC AC: -40...+55 C IP 40 EN 60529 RTI EN 116000-3 10 g / 5 g 5 g 10...150 Hz o 160 02 Tehnical data.indd 160 9/2/2016 1:46:03 AM EVE - ETIREL Technical data Table 2: Coil data DC voltage version Coil code Rated voltage V DC Coil resistance at 20 °C Ω Acceptable resistance Coil operating range V DC min. (at 20 °C) max. (at 55 °C) 012DC 12 160 ± 10% 9,6 13,2 024DC 24 640 ± 10% 19,2 26,4 024AC 24 158 ± 10% 19,2 26,4 230AC 230 16100 ± 10% 184,0 253,0 AC voltage version Dimensions ERM 2 Lockable test button ERM 4 Lockable test button Connection diagram (pin side view) ERM 2 ERM 4 Meaning of color codes: Ordering designation ERMX-YYYYYZ X – Number of contacts: 4: 4 CO (4 changeover) 2: 2 CO (2 changeover) YYYYY – Coil code: 024AC: 24 V AC 50/60 Hz 230AC: 230 V AC 50/60 Hz 024DC: 24 V DC 012DC: 12 V DC green - DC coils Z – Additional features: L – Light indicator (smd LED - red) Example: ERM4-024DCL Electromagnetic relay for plugin sockets with mechanical indication and lockable test button, four changeover contacts, coil voltage 24 V DC with light indicator. 02 Tehnical data.indd 161 orange - AC coils 161 9/2/2016 1:46:08 AM Electrical life at AC resistive load. Switching frequency: 1 200 cycles/hour Fig. 1 ERM 4 Number of cycles N ERM 2 Number of cycles N EVE - ETIREL Technical data Breaking capacity [kVA] Breaking capacity [kVA] Electrical life reduction factor at AC inductive load Fig. 2 Reduction factor ERM 4 Reduction factor ERM 2 Power factor Power factor N - electrical life at AC1 Max. DC resistive load breaking capacity DC voltage [V] A - resistive load DC1 B - inductive load L/R = 40 ms DC current [A] ERM 4 DC current [A] ERM 2 Fig. 3 DC voltage [V] 162 02 Tehnical data.indd 162 9/2/2016 1:46:10 AM Contact material selection for different load types AgNi - for resistive or inductive loads, EVE - ETIREL Technical data ERM2 and ERM4 Mounting ERM 2 ERM 4 protecting modules type ERC are available as accessories /sockets (see below) protecting modules type ERC are available as accessories /sockets (see below) *Plug-in sockets ERB2-T and ERB2-M may be linked with interconnection strip type ER-TERMINAL *Plug-in sockets ERB4-T and ERB4-M may be linked with interconnection strip type ER-TERMINAL Relays ERM2 are designed for mounting in plug-in sockets, standard version includes mechanical indicator with lockable front test button. Relays ERM2 are designed for: screw terminals plug-in sockets ERB2-T* sockets ERB2-M* with clip ER-CLIP 35 mm rail mount acc. to EN 60715 or panel mounting Relays ERM4 are designed for mounting in plug-in sockets, standard version includes mechanical indicator with lockable front test button. Relays ERM4 are designed for: screw terminals plug-in sockets ERB4-T* sockets ERB4-M* with clip ER-CLIP 35 mm rail mount acc. to EN 60715 or panel mounting Plugin Sockets And Accessories ERB2-T and ERB4-T Plugin sockets (base) type T Dimensions Screw terminals Max. tightening moment for the terminal: 0,7 Nm 35 mm rail mount acc. to EN 60715 or on panel mounting 76,3 x 27 x 42,5(80) mm* *In the bracket the height of socket with retainer / retractor clip is shown. Two poles Four poles 12A, 300 V AC 6A, 300 V AC For ERM2 For ERM4 Connection diagram 02 Tehnical data.indd 163 163 9/2/2016 1:46:10 AM EVE - ETIREL Technical data Dimensions ERB2-M and ERB4-M Plugin sockets (base) type M Screw terminals Max. tightening moment for the terminal: 0,7 Nm 35 mm rail mount acc. to EN 60715 or on panel mounting 75 x 27 x 61(82) mm* *In the bracket the height of socket with retainer / retractor clip is shown. Two poles Four poles 12A, 300 V AC 6A, 300 V AC For ERM2 For ERM4 Connection diagram Removing the relay from the socket with a retrainer / retractor clip Protection RC modules type ERC_AC It protects against EMC disturbance and limits overvoltage. 6/24 V AC ERC-024AC 110/240 V AC ERC-230AC 6…24 V ACDC ERC-024ACDCL 24…60 V AC DC ERC-060ACDCL 110…230 V ACDC ERC-230ACDCL Protection RC modules type ERC_ACDCL It limits overvoltage on AC and DC coils. Coil energizing indication. Modules are parallely connected with relay coil Interconnection strip ER-CLIP designed for the co-operation with plug-in sockets ERB of miniature industrial relays, which are equipped with screw terminals; sockets and relays are mounted on 35 mm rail mount acc. to EN 60715. bridges common input signals (coil terminals A1 or A2) maximum permissible current is 10 A / 250 V AC, possibility of connection of 6 sockets or relays Dimensions 164 02 Tehnical data.indd 164 9/2/2016 1:46:12 AM EVE - ETIREL Technical data Miniature Electromagnetic Relays Table 1: Technical data MER2 2 CO AgNi 250 V / 440 V 5 V AgNi Number and type of contacts Contact material Rated / max. switching voltage AC Min. switching voltage Rated load (capacity) AC1 AC15 AC3 DC1 DC13 Min. switching current Rated current Max. breaking capacity AC1 Min. breaking capacity Contact resistance Max. operating frequency (cycles/hour) • at rated load AC1 • no load Coil data Rated voltage 50/60 Hz AC 8 A / 250 V AC 3 A / 120 V 1,5 A / 240 V (B300) 550 W (single-phase motor) 8 A / 24 V DC (see Fig. 3) 0,22 A / 120 V 0,1 A / 250 V (R300) 5 mA Agni 8A 2000 VA 0,3 W AgNi ≤ 100 mΩ 600 72 000 DC Must release voltage Operating range of supply voltage AC Rated power consumption DC Insulation according to EN 60664-1 Insulation rated voltage Rated surge voltage Overvoltage category Insulation pollution degree Dielectric strength • between coil and contacts • pole - pole Contact - coil distance • clearance • creepage General data Operating / release time (typical values) Electrical life • resistive AC1 • cosΦ • DC L/R = 40 ms Mechanical life (cycles) Dimensions (L x W x H) Weight Ambient temperature • storage • operating Cover protection category Environmental protection Shock resistance (NC) Vibration resistance Solder bath temperature/ soldering time 02 Tehnical data.indd 165 12 ... 240 V 3 ... 110 V DC: ≥ 0,1 Un AC: ≥ 0,15 Un See Tables 1, 2 and Fig. 4, 5 0,75 VA 0,4 ... 0,48 W 400 V AC 4000 V 1,2 / 50 µs III 3 5000 V AC type of insulation: reinforced 2500 V AC type of insulation: basic ≥ 10 mm ≥ 10 mm 7 ms / 3 ms 8 A, 250 V AC see Fig. 2 0,15 A, 220 V DC > 105 > 3x107 29 x 12,7 x 15,7 m 14 g > 105 -40 ... +85 0C AC: -40 ... +70 0C DC: -40 ... +85 0C IP40 / IP67 RTII / RTIII 20 g 5g 10 ... 150 Hz max. 270 0C / max. 5 s 165 9/2/2016 1:46:12 AM EVE - ETIREL Technical data Table 2: Coil data DC voltage version Rated voltage V DC Coil code Coil resistance at 20 °C Ω Acceptable resistance Coil operating range V DC min. (at 20 °C) max. (at 20 °C) 005DC 5 60 ± 10% 3,5 12,7 012DC 12 360 ± 10% 8,4 30,6 024DC 24 1440 ± 10% 16,8 61,2 AC 50/60 Hz voltage version 024AC 24 400 ± 10% 19,2 28,8 230AC 230 38 500 ± 10% 184,0 276,0 12,7 Connection diagram (pin side view) 7,5 12,7 Dimensions 5 15 5 2,5 15,7 3,9 3,9 15,7 29 Electrical life at AC resistive load. Switching frequency: 600 cycles/hour Fig. 1 Electrical life reduction factor at AC inductive load Fig. 2 166 02 Tehnical data.indd 166 9/2/2016 1:46:14 AM Max. DC resistive load breaking capacity Fig. 3 EVE - ETIREL Technical data Coil operating range = DC Fig. 4 Coil operating range = AC 50 Hz Fig. 5 Pinout (soldier side view) Mounting Relays MER2 are designed for: direct PCB mounting screw terminals plug-in sockets MERB-T and MERB-M 02 Tehnical data.indd 167 167 9/2/2016 1:46:16 AM EVE - ETIREL Technical data Plugin Sockets And Accessories MERB-T Plugin sockets (base) type T MERB-M Plugin sockets (base) type M Screw terminals Max. tightening moment for the terminal: 0,7 Nm 35 mm rail mount acc. to EN 60715 or on panel mounting 75,3 x 15,5 x 61(67) mm* *In the bracket the height of socket with retainer / retractor clip is shown. Screw terminals Max. tightening moment for the terminal: 0,7 Nm 35 mm rail mount acc. to EN 60715 or on panel mounting 78,1 x 15,9 x 61(66,5) mm* *In the bracket the height of socket with retainer / retractor clip is shown. Two poles, 5mm pinout Two poles, 5mm pinout 12A, 300 V AC 12A, 300 V AC Dimensions Dimensions Connection diagram Connection diagram COM NC NO COM NO NC COIL COIL 168 02 Tehnical data.indd 168 9/2/2016 1:46:21 AM EVE - ETIREL Technical data SLIM RELAYS SSR & SER, Electromagnetic and solid Table 1: Technical data Number and type of contacts Contact material Rated / max. switching voltage AC Min. switching voltage Rated load (capacity) AC1 DC1 Min. switching current Max. inrush current / Max. non-repeat surge current Rated current Max. breaking capacity AC1 Min. breaking capacity Contact resistance Max. operating frequency (cycles/hour) • at rated load AC1 • no load I2t for fusing SER1; Contact data 1 CO AgSnO2 400 V AC / 250 V DC 10 V AC / DC SSR1; Output circuit - Triac 1 NO 400 V AC / 440 V AC 20 V AC 6 A / 250 V AC 6 A / 24 V DC; 0,15 A / 250 V DC 100 mA 10 A (t=20 ms) 1,2 A / 400 V AC 10 mA 30 A (t=20 ms) 6A 1 500 VA 1W ≤100 mΩ 100 mA, 24 V 1,2 A - 360 72 000 - 5,1 A2s (t=1-10 ms) dI/dt - 50 A/µs dV/dt - 40 V/µs Input circuit Rated voltage AC: 50/60 Hz AC/DC 24 V; 230 V Must release voltage / Turn-off voltage AC: ≥ 0,2 Un DC: ≥ 0,1 Un Must operate voltage AC & DC: ≤ 0,8 Un AC/DC Rated power consumption 0,3 ... 1,6 VA / 0,3 ... 1,6 W 0,3 VA / 0,3 W 24 V AC/DC AC/DC 1,6 VA / 1,6 W 230 V AC/DC Insulation according to PN-EN 60664-1 400 V AC 600 V AC Insulation rated voltage 4 000 V 1,2 / 50 µs Rated surge voltage III Overvoltage category 3 2 Insulation pollution degree Dielectric strength 4 000 V AC 50/60 Hz, 1 min. (type of insulation: reinforced) 4 000 V AC 50/60 Hz, 1 min. (type of insulation: reinforced) • input - output 6 000 V 1,2 / 50 µs • input - output 2 500 V AC 50/60 Hz, 1 min. • mass - input, output 1 000 V AC 50/60 Hz, 1 min. (type of clearance: micro-disconnection) • contact clearance Input - output distance • clearance ≥ 6 mm • creepage ≥ 8 mm General data Operating / release time (typical values) AC: 7 ms DC: 6 ms / AC: 15 ms DC: 10 ms 10 ms max. (zero turn-on) / 10 ms max. Electrical life > 0,6 x 105 6 A, 250 V AC; > 2 x 105 2 A, 250 V AC • resistive AC1 (cos φ = 0,4) 105 6 A, 30 V DC • resistive DC1 > 2 x 107 Mechanical life (cycles) 93,8 x 6,2 x 80 mm Dimensions (L x W x H) 40 g Weight Ambient temperature -40...+70 oC -40...+70 oC • storage -40...+55 oC (-40...+60 oC 24 V DC) -40...+55 oC • operating IP 20 PN-EN 60529 Protection category RTI PN-EN 116000-3 Environmental protection 10 g Shock resistance 5 g 10...500 Hz Vibration resistance 02 Tehnical data.indd 169 169 9/2/2016 1:46:22 AM EVE - ETIREL Technical data Input data SER1 Input data SSR1 Input - voltage range, V Interface relay code Rated input voltage, Un Power of input circuit min. (20 °C) max. (55 °C) SER1-024ACDC 24 V AC/DC 0,5 VA / 0,5 W 19,2 26,4 SER1-230ACDC 230 V AC/DC 0,8 VA / 0,8 W 184,0 253,0 Dimensions Interface relay code Rated input voltage Un Power of input circuit SSR1-024ACDC SSR1-230ACDC 24 V AC/DC 230 V AC/DC 0,3 VA / 0,3 W 1,6 VA / 1,6 W Connection diagram SER1-024ACDC / SER1-230ACDC SER1-024ACDC SER1-230ACDC SSR1-024ACDC / SSR1-230ACDC SSR1-024ACDC SSR1-230ACDC SR-TERMINAL 170 02 Tehnical data.indd 170 9/2/2016 1:46:24 AM
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement