Specifications
True-50
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL
TRUE-50
HEIGHT
FRONT
WIDTH
FRONT
WIDTH
BACK WIDTH
True
50" Direct Vent Gas Fireplace
BACK
WIDTH
HEIGHT
DEPTH
DEPTH
VIEWING
AREA
GLASS SIZE
Actual
Actual
Framing
Framing
Actual
Actual
Framing
Framing
Actual
Actual
Framing
Framing
Actual
Actual
Framing
Framing
75
73-9/16
73-5/16
73-9/16
66-5/8
65
24
24
49-7/8 x 40-1/16
73-5/16" [1862]
36-11/16"
[932]
16"
[406]
Top
75" [1905]
66-5/8"
[1692]
40-1/16"
[1018]
49-7/8" [1267]
53-7/8" [1368]
24"
[610]
Front
Heat-Zone
Port
23-1/2"
[597]
®
Gas
Access
Electrical
Access
2-3/4"
[70]
63-15/16"
[1624]
Heat-Zone
Port
50-3/8"
[1280]
3-7/8"
[98]
10-7/8"
[276]
16-1/8"
[410]
Left
Additional information can be found online at www.heatnglo.com
Right
®
Specifications
True-50
Appliance Location
Framing Dimension
84-1/4" [2140]
31-1/2"
[800]
10"
[254]
31-1/2"
[800]
73-9/16"
[1868]
84-1/4"
[2140]
36-13/16"
[935]
73-9/16"
[1868]
119-1/8"
[3026]
23-1/2"
[597]
23-1/2"
[597]
73-9/16" [1868]
36-13/16"
[935]
65"
[1651]
Wall Penetration
Do not pack with insulation
or other material.
24"
[610]
73-9/16" [1868]
Clearances to Combustibles
10"
12"
82-3/16"
[2088]
*83-3/16"
[2113]
* Shows center of vent framing hole
with minimum vertical for top venting.
Center of hole is 1" [25] above center
of horizontal vent pipe.
52"
[1321]
from appliance
opening to
ceiling
0"
96-3/16" [2443]
from bottom of
fireplace to ceiling
MANTEL leg/wall PROJECTIONS
Combustible Mantel
See install manual
section 3.D
1/2" Building Material
36"
[914]
Combustible
Column
7" Min
Fireplace
14" Min
Opening
Factory-supplied
non-combustible
board
Combustible or
non-combustible wall
1"
[25]
1"
[25]
4" Maximum
Hearth Extension
1/2" Building Material
Non-combustible
Column
See section 13.E
for required
clearances
14" Min
Fireplace
Opening
Factory-supplied
non-combustible
board
6" Maximum
Combustible or
non-combustible wall
Non-combustible Mantel
12"
[305]
MANTEL PROJECTIONS
NO
N-
1/2"
NON-COMBUSTIBLE
MATERIAL
CO
71-5/16"
[1811]
12
9
MB
US
TIB
LE
6
3
24
21
1
15
12
18
PRODUCT LISTING CODES
FIREPLACE
OPENING
Measurement from fireplace
opening to bottom of unit=44-3/16"
US
ANSI Z21.88b-2009
CAN
CSA 2.33a-2009
UL307B
Note: All measurements in inches.
Note: Measurement is taken from top of the opening,
NOT the top of the replace.
Combustible Mantel Projections. See installation manual for
Non-combustible Mantel Projections
Product information provided is
not complete and is subject to
change without notice. Product
installation must adhere strictly
to instructions accompanying
product to avoid risk of fire and
potential injury.
Additional information can be found online at www.heatnglo.com
A brand of Hearth & Home Technologies®
Lakeville, MN
Web: heatnglo.com
Phone: 888-427-3973 952-985-6000
GS/HNG/TRUE-50_0614
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement