ALMEMO
®
Measuring Instruments
The ALMEMO
®
system
The ALMEMO
®
system comprises an
ALMEMO
®
measuring instrument and intelligent ALMEMO
®
connectors for the relevant sensor equipment.
An extensive range of measuring instrument variants is thus available - from the single-channel transmitter right through to data acquisition systems with over 1000 measuring points.
The only differences between most of the measuring instruments in the ALMEMO
® series concern their housing (i.e. handheld instruments, desktop instruments, 19inch systems, fitted panel instruments, transmitters, etc.), the number of measuring inputs (1 to 250), the display, output, and operating controls, and their respective power supplies.
As soon as a sensor or interface cable is connected, the ALMEMO
®
measuring instrument will, thanks to the intelligent
ALMEMO
®
connector system, be completely programmed right through to process scheduling.
These measuring instruments provide a uniform range of functions with many configurable options. All parameters can be accessed via the interface and can, since the media in the connectors are always overwritten, be freely modified as and whenever necessary.
The ALMEMO
®
principle: Only one measuring instrument for all sensors
An extensive range of transducers, sensors, and signals can be connected to any measuring input on virtually any
ALMEMO
®
measuring instrument - all via the ALMEMO
®
plug system Since all the sensor data is saved in the connector, no extra programming is required; as soon as a sensor is connected, the measuring instrument is configured automatically.
The sensor data memory (EEPROM) ensures that each sensor can be identified, scaled, and calibrated - all on the basis of its own unique designation. This system of individual sensor designations avoids confusion and makes the measuring setup clear and logical. Sensor errors can be corrected within the plug, turning simple sensors into precision transducers.
Standard signals can be displayed in their original dimensions. For multi-purpose sensors (e.g. temperature and humidity) only one shared plug will usually be required. Programming can be protected by a graduated locking function.
With ALMEMO
®
measuring instruments you will not need new sensors
For your existing sensors we will provide you with a matching adapter that you can fit quickly and easily.
You can also program ALMEMO
®
plugs yourself quickly and easily via keypad, terminal, or software. The data medium in the plug can be overwritten as and whenever necessary.
ALMEMO
®
measuring instruments are ideal for all sorts of application
All incorporate the same measuring input circuitry. For applications that are not sector-specific there are more than 60 standard measuring ranges available, e.g. for measuring :
Temperature, humidity, flow velocity, flow rate, heat flow, pressure, rotational speed, frequency, resistance, current, voltage, force, strain factor, displacement, pH value, redox potential, conductivity, O
2
, CO
2
, CO,
, etc. Maximum and minimum values O
3 are saved automatically. Measured values can be averaged over a series of individual measurements, over the output cycle, or over the actual measuring duration; limit values can be monitored in terms of programmable maximum / minimum values. Measured values can be corrected with regard to zero point and gain and can be scaled by factor, base value, exponent, and units.
01.02
ALMEMO
®
Measuring Instruments
ALMEMO
®
measuring instruments are real individuals
ALMEMO
®
instruments automatically recognize the specifications of a sensor as it is connected. Specific functions will only be activated as and when the appropriate connector, interface cable, or module is detected. With humidity sensors the dew point, mixture ratio, vapor pressure, and enthalpy will be calculated automatically. Measuring operations involving psychrometers, dynamic pressure probes, or probes for solute oxygen may require pressure compensation; for this purpose the prevailing atmospheric pressure can be entered manually or calculated automatically by an integrated pressure transducer.
When measuring dynamic pressure, pH value, atmospheric humidity, solute oxygen, or conductivity it is possible similarly to perform temperature compensation.
When using flow sensors to measure volume flow the appropriate cross-section can be entered. For certain special sensors there are connectors available incorporating an integrated adapter circuitry.
ALMEMO
®
measuring instruments meet even the most stringent requirements
ALMEMO
®
devices incorporate a highresolution 16-bit A/D converter, digital linearization (for Pt100 sensors with the new ITS 90 temperature scale), and digital calibration. Optimal cold junction compensation is ensured by means of precision thermistors incorporated in the socket spring. Measuring inputs, power supply, and interfaces are all electrically isolated from each other.
The ALMEMO
®
data acquisition system adapts to your requirements
The internal measured data memory incorporated in ALMEMO
®
data loggers can be expanded by adding external capacity and can be configured either as linear or ring memory.
This memory can be read out selectively according to time or number. The switchover between measuring points is electrically isolated using semiconductor relays that are totally wear-resistant.
Continuous measuring point scanning at 10 or 50 measuring operations per second can thus be performed troublefree. Measuring point scans can be individually programmed. Measuring cycles and output cycles can be selected independently; measured values, average values, and maximum / minimum values can be selectively output and / or saved to memory. The start / stop of each measuring point scan can be variably controlled (by keypad or interface, by date and time-of-day, by limit values, or by an external signal). All measuring instruments can be addressed via interface and are thus fully network-capable. Up to
100 devices can be networked either via cable or over a wireless link. The output of measured values from all devices in the whole network can be initiated from any one such device. For covering longer distances RS422 drivers and distributors are available. This system minimizes hardware requirements, cabling costs, and possible EMC problems, and can be expanded as and when required.
ALMEMO
®
measuring instruments accept virtually any peripheral equipment while maintaining optimal data transmission
Analog or digital interfaces are not integrated in the measuring instruments themselves but in the connectors and connecting cables. Depending on requirements a wide variety of adapters can be connected, e.g. analog outputs, various interfaces (RS232, RS422, optic fiber, current loop, Ethernet,
Bluetooth), alarm signaling devices, or trigger inputs. The data can also be transmitted via Internet or via mobile phone network.
ALMEMO
®
measuring instruments provide evaluation of measured data easily and conveniently
Suitable output formats are provided for printers or spreadsheet software. For the graphical presentation and the evaluation of measured data there are various software packages available.
ALMEMO
®
instruments can be programmed quickly and easily
The software protocol and the commands list are identical for all devices. Only one terminal is enough to program all parameters and to scan the measured data.
There is a free configuration software,
ALMEMO
®
Control, with terminal, available for this purpose.
01.03
ALMEMO
®
Measuring Instruments
General technical specifications
Inputs
Channel switching between input sockets for analog sensors
Cold junction compensation (CJC)
Nominal temperature
Sensor power supply
Self-calibration
Monitoring functions
4-contact with photo-MOS relays
Potential separation maximum 50 V
Measuring modules with higher potential separation (see chapter „Input modules“)
Offset voltage <5 µV effective in range -30 to +100 °C, Accuracy ±0.2 K (±0.01 K / °C)
22 °C ±2 K
6 to 12 V depending on power supply
Automatic zero-point correction, measuring current calibration
Automatic sensor recognition and sensor breakage detection
Precision class
ALMEMO
Overload at 2.5 mops
®
Input current
series
Measuring rates
Measuring operations per second (mops)
Input range
Measuring current
System accuracy
Temperature drift
C
2450, 2420
2.5 mops
Basic measuring instruments
B
2490, 2590
2.5 / 10mops
Professional measuring instruments
A
2470, 2790
2590A
2.5 / 10mops
Precision measuring instruments
2890, 4390
5690, 8490
8590, 8690
AA
2690A, 710
2.5 / 10 / 50 / 100mops
Option 400mops* | Option 500mops *
0.26 to +2.6 V
-4 to +5 V
< 2nA
-2 to +5 V
-2 to +5 V
< 20nA
0.1% of measured value ±4 digits
0.01% / K (100 ppm)
Pt100/1000:
0.3mA
0.03% of measured value ±4 digits
0.005% / K (50 ppm) meas. range 2.6 V:
-2 to +3 V in all other meas. ranges
-1.9 to +2.9 V
-2 to +5 V
100pA
Pt100/1000: 0.3mA
meas. range 2.6 V:
-3 to +3 V in all other meas. ranges
-2.3 to +1.3 V
± 12V meas. range 2.6 V:
-2 to +3 V in all other meas. ranges
-1.9 to +2.9 V
Meas. range 2.6 V:
500 nA in all other meas. ranges
500 pA
± 12V
100pA
Pt100: 1mA, Pt1000: 0.1mA
0.03% of measured value ±3 digits
0.003% / K (30 ppm)
0.02% of measured value ±2 digits
0.003% / K (30 ppm)
*Measuring rate 400 mops (Option SA0000Q4)
*Measuring rate 500 mops (Option SA0000Q5):
It is also possible, in addition to the standard conversion rates, to set 400 or 500 mops (measuring operations per second). At the rate of 400 or
500 mops just one selected measuring channel can be saved. This can only be used with sensors with voltage or current ranges or with NTC sensors. Nor is it possible to change channels in the course of a measuring operation.
The resolution, accuracy, and sensitivity to disturbance caused by mains hum or electromagnetic interference are comparable with measuring operations performed at a rate of 50 mops. Care must be taken to ensure that the environment is free from interference and that the sensor lines are kept short.
Data can only be output to a micro SD card. Accessories ZA1904SD Memory connector with micro SD Data is saved in table format
(separated by semi-colons) and with a time-stamp resolution of 0.0001 seconds. This format can be processed using the WinControl software
(as of version 6.1.1.6).
01.04
ALMEMO
®
Measuring Instruments
Measuring ranges
Sensor type Type
Resistance temperature detectors:
Pt100 / Pt1000 -1 4-wire FP Axxx
Pt100 / Pt1000 -2 4-wire FP Axxx
Pt100 -3 4-wire
Ni100/1000 4-wire
NTC type N
Thermocouples
NiCr-Ni (K)
NiCroSil-NiSil (N)
Fe-CuNi (L)
Fe-CuNi (J)
Cu-CuNi (U)
Cu-CuNi (T)
PtRh10-Pt (S)
PtRh13-Pt (R)
PtRh30-PtRh6 (B)
AuFe-Cr
Electrical and digital signals:
FP Axxx
FN Axxx
FT Axxx
range
5.0 to
5.0 to
-200.0 to +850.0
-200.00 to +400.00
-8.000 to + 65.000
-60.00 to + 240.00
-50.00 to +125.00
-200.0 to +1370.0
-200.0 to +1300.0
-200.0 to +900.0
-200.0 to +1000.0
-200.0 to +600.0
-200.0 to +400.0
0.0 to +1760.0
0.0 to +1760.0
+400.0 to +1800.0
-270.0 to +60.0
Millivolts DC
Millivolts 1 DC
Millivolts 2 DC
Volts DC
-10.0 to +55.0
-26.0 to +26.0
-260.0 to +260.0
-2.6 to +2.6
Volts DC -26 to +26
For measuring bridges Supply 5 V (Example) -26.0 to +26.0
For potentiometers Supply 2.5 V
Volt AC (50 Hz to 2 kHz) (Example)
Volt AC (11 Hz to 250 Hz) (Example)
Ampere AC (11 Hz to 250 Hz) (Example)
Volts DC (sampling rate 1 kHz) (Example)
Ampere DC (sampling rate 1 kHz) (Example)
Milliamperes DC
Percent (4 / 20mA DC)
Ohms
Ohms
Frequency
Pulses / measuring cycle
Digital interface
Digital input
Capacitive humidity sensors:
Rel: humidity FH A646
Rel: humidity with TC FH A646-R
Dew-point temperature
Mixture ratio
Partial vapor pressure
Enthalpy
Psychrometer
Wet temperature
Relative humidity
Dew-point temperature
FN A846
Mixture ratio
Partial vapor pressure
Enthalpy
-2.6 to +2.6
0 to +26
0 to +400
0 to +10.00
0 to +400
0 to +10.00
-32.0 to +32.0
0.0 to 100.0
0.00 to 500.00
0.0 to 5000.0
0 to 15000
0 to 65000
0 to 65000
0.00 to 100.00
98.0
98.0
-25.0 to +100.0
0.0 to 500.0
0.0 to 1013.2
0.0 to 400.0
0.00 to +100.00
0.0 to +100.0
-25.0 to +100.0
0.0 to 500.0
0.0 to 1013.2
Units Resolution
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C mV mV mV
*
V mV
*
V
V
A
V
A
*
%
*
*
Hz
%
%H
%H
°C g/kg mbar kJ/kg
°C
%H
°C g/kg mbar
0.0 to 400.0 kJ/kg
0.01 K
0.001 K
0.1 K
0.01 K
V
1 µV
V
mA
0,01 %
Ω
Ω
0,1 %
0,1 %
0.1 K
–
±0,5 %
±0.2 K
0.1 g/kg ±0.5 % of measured value
0.1 mbar ±0.1 mbar ±0.1 % of measured value
0.1 kJ/kg
0.1 %
0.1 kJ/kg
0.1 K
0.1 K
0.1 K
0.1 K
1 µV
1 µV
0.01 mV
1 mV
0.1 V
1 V
0.01 A
1 V
0.01 A
1 Hz
0.01 K
0.1 K
0.1 g/kg
0.1 K ±0.05 K ±0.05 % of measured value ZA 9030 FS1/4
±0.05 K
±0.002 K
±0.05 K
±0.05 K
±0.3 K
±0.3 K
±0.3 K
±0.1 K
–
–
–
0.1 mV
–
-
0.1 mV
–
–
–
–
–
1 µA
0.01 Ω
0.1 Ω
–
–
–
–
±0.5 % of measured value
ZA 9846 AK
±0.05 K
±1,0 %H
±0.2 K
±0.5% of measured value
ZA 9030 FS2 / 5
ZA 9030 FS7
ZA 9030 FS3 / 6
ZA 9040 FS
0.1 K ±0.05 K ±0.05 % of measured value ZA 9020 FS
0.1 K ±0.05 K ±0.05 % of measured value ZA 9021 FSN
0.1 K ±0.05 K ±0.05 % of measured value ZA 9021 FSL
0.1 K ±0.05 K ±0.05 % of measured value ZA 9021 FSJ
0.1 K ±0.05 K ±0.05 % of measured value ZA 9000 FSU
0.1 K ±0.05 K ±0.05 % of measured value ZA 9021 FST
ZA 9000 FSS
ZA 9000 FSR
ZA 9000 FSB
ZA 9000 FSA
ZA 9000 FS0
ZA 9000 FS1
ZA 9000 FS2
– ZA 9000 FS3
ZA 9602 FS
ZA9650 FS1V
- ZA9025 FS3
ZA 9603 AK3
ZA 9903 AB5
ZA 9904 AB2
ZA 9900 AB5
ZA 9901 AB4
– ZA 9601 FS1
ZA 9601 FS2
– ZA 9003 FS
– ZA 9003 FS2
ZA 9909 AK1U
ZA 9909 AK2U
ZA 9919 AKxx
ZA 9000 ES2
0.1 mbar ±0.1 mbar ±0.1% of measured value
±0.5% of measured value.
* Data may vary depending on device. (see relevant device data sheet)
01.05
ALMEMO
®
Measuring Instruments
Sensor type Type
Flow sensors
Rot. vane, snap-on head FV AD15-Sx (e.g.) 0.50 to 40,00
Rotating vane Macro
Water turbine
FV AD15-MA1
FV AD15-WM1
Dynamic pressure sensor FD A602-S1K
Dynamic pressure sensor FD A602-S6
Hot-wire anemometer FV A935-TH4
Hot-wire anemometer FV A935-TH5
Hot-wire anemometer FV A605-TA1
Hot-wire anemometer FV A605-TA5
Chemical probes
Conductivity
O
O
O
2
2
2
dissolved saturation FY A640-O2
dissolved, concentr: FY A640-O2
in gases
O
3
in gases
CO probe
CO
2
in gases pH probe
Redox probe
Optical radiation (Examples)
Lux measuring probe
Lux measuring probe
Lux measuring probe
UV measuring probe
FY A641-LF (e.g.)
FY 9600-O2
FY 9600-O3
FY A600-CO (e.g.)
FY A600-CO2 (e.g.) 0.000 to 2.500
FY96PH-Ex
FY96RX-Ex
FL A613-VL
FL A603-VL2
FL A603-VL4
FL A613-UV
0.10 to 20.00
0.00 to 5.00
0.5 to 40.0
1.8 to 90.0
0 to 2.000
0 to 20.00
0.01 to 1.000
0.15 to 5.00
0 to 20.000
0 to 260
0.0 to 40.0
1 to 100
0 to 300
0 to 300
0.0 to 14.00
0.0 to 2600.0
0 to 260000
0.05 to 12500
1 to 250000
0 to 87.00
Units
m/s m/s m/s m/s m/s m/s m/s m/s m/s mS
% mg/l
% ppb ppm
% pH mV lux lux lux
W/m
2
Resolution
0.01 m/s
0.01 m/s
0.01 m/s
0.1 m/s
0.1 m/s
0.001 m/s
0.01 m/s
0.001 m/s
0.01 m/s
0.001 mS
1%
0.1 mg/l
1%
20 ppb
1 ppm
–
–
–
–
–
–
–
-
± 0.1 m/s
± 0.1 m/s
–
–
–
–
0,01% ±0.2% of measured value
0.01 pH
0.1 mV
1 lux
0.01 lux
1 lux
0.01 W/m
2
UVA measuring probe FL A603-UV24 0.0004 to 100 mW/cm
2
0.1 µW/cm
2
±0.2% of measured value
–
±0.2 mg/l
–
–
–
–
–
ZA 9610 AKY4W
ZA 9610 AKY5W
Radiometric probe
Photosynthesis probe
FL A603-RW4 0.00004 to
FL A603-PS5
Other connectable sensors / transducers (Examples)
10 mW/cm
0.0002 to 100 mmol/m
2
2
0.01 µW/cm s 0.1µmol/m
2
2 s
Heat flow plates FQ Axxx
Moisture content probe FH A696-MF
Differential pressure
Barometer
Alarm value
Thermal coefficient
Measured value
FD A612-SR
FD A612-SA
ZA 9909-AK2U
M (q) / M (∆T)
-260.0 to +260.0
0 to 50.0
0 to 1000
0.0 to 1050 mbar
Pressure transducer FDA FD A602-xx (e.g.) 0.00 to 10.00
Force transducer FK Axxx (e.g.)
Displacement transducer FW Axxx(e.g.)
Tachometer
Function values
Differential
Maximum value
Minimum value
Average value over time
Average value over measuring point
Summation over measuring points
Total number of pulses ZA 9909-AK2U
Pulses / print cycle
FU A919-2
0.0 to 50.00
0.0 to 150.00
8 to 30000
0 to 65000
0 to 65000
0 to 65000
0.0 to 100.00
Wet-bulb globe temperature (WBGT) (0.1 TD + 0.7 TW +0.2 TG) mV
% mbar bar kN mm rpm
%
0.01 mV
0,1%
0.1 mbar
0.1 mbar
0.01 bar
0.01 kN
0.01 mm
1 rpm
–
–
–
-
–
–
–
–
–
–
–
–
–
–
–
–
ZA 9007 FS
ZA 9909 AK4U
Cold junction temperature
Number of averaged values
Volume flow 0 to 65000 m
3
/h 1 m
3
°C
/h
01.06
ALMEMO
®
Measuring Instruments
Outputs
ALMEMO
®
socket A1
ALMEMO
®
socket A2
Digital interface
Analog output
Networking
Saving data
Analog output
Trigger input
Relay output
Relay output
Baud rates up to 115.2 kilobaud
Data : 8 bit serial, 1 start bit, 1 stop bit, no parity
ALMEMO
®
data link via USB, RS232, Ethernet wireless link via Bluetooth or RS422
(see chapter „Networking“)
ALMEMO
®
analog cable and analog interface
(see chapter „Output modules“)
ALMEMO
®
network cable or wireless via Bluetooth
(see chapter „Networking“)
ALMEMO
®
memory connector with memory card
(see chapter „General accessories“)
ALMEMO
®
analog cable and analog interface
(see chapter „Output modules“)
ALMEMO
®
trigger cable and trigger interface
(see chapter „Output modules“)
ALMEMO
®
relay cable and relay interface
(see chapter „Output modules“)
ALMEMO
®
relay cable and relay interface
(see chapter „Output modules“e
Mains adapter and DC supply cable
see chapter „General accessories“
01.07
ALMEMO
®
Measuring Instruments
Input connector
ALMEMO
®
standard plug
• The ALMEMO
®
measuring system makes it possible to process four channels per measuring input – depending on the sensor and the measuring instrument.
• The ALMEMO
®
plug incorporates 6 screw terminals - 2 for the sensor‘s power supply and 4 for its measuring signal.
• With Pt100 sensors using 4-conductor circuitry all 4 free connections will be required for the measuring signal.
Only one sensor of this type can be connected therefore per measuring input.
• Electrical signals only require 2 connections for the measuring signal. One plug can thus acquire two diff erent measuring signals over just one measuring channel.
• An atmospheric humidity sensor can example usually be combined with a temperature sensor. The associated operands (e.g. dew point, mixture ratio, partial vapor pressure, enthalpy) are programmed in the plug as additional measuring channels.
ALMEMO
®
D6 plugs for digital sensors
• The digital ALMEMO
®
D6 sensor can be connected to any ALMEMO
®
measuring instrument without in any way aff ecting its measuring accuracy. The A/D converter incorporated in the ALMEMO
®
D6 sensor is exclusively responsible for the measuring accuracy of the whole system.
• The digital ALMEMO
®
D6 sensor is calibrated without involving the ALMEMO
®
measuring instrument
(DAkkS / factory) and can be replaced or exchanged as and whenever necessary.
• The connecting cable for the digital ALMEMO
®
D6 sensor can be extended using pluggable extension cables quickly and easily and without any line losses. (see chapter „General accessories“) These digital extension cables provide high transmission reliability; they have no eff ect on measuring accuracy.
• The confi guration of the digital ALMEMO
®
D6 sensors (i.a. the selection of the measuring ranges) is eff ected by an ALMEMO
®
V7 measuring instrument, e.g. ALMEMO
®
710 or ALMEMO
®
202 (refer to chapter ALMEMO
®
Universal Measuring Instruments), or directly on the PC by using the USB adapter cable ZA1919AKUV (refer to chapter Network technology).
New:
ALMEMO
®
D7 plug for digital sensors
• With the ALMEMO
®
D7 plug technology, the measurement ranges of the sensors are completely independent of the measuring instrument. Each ALMEMO
®
D7 measurement plug features up to 10 display and function channels.
• The new ALMEMO
®
D7 measurement plug enables high measuring speeds or high measuring accuracy applicable for a vast variety of measuring tasks.
• The ALMEMO
®
D7 plug measures dynamic processes using the setting High Speed Measuring Operations at high sampling rate. The ALMEMO
®
V7 measuring instrument saves the measured values, and the WinControl measuring software displays them in graphical form. In case high resolution and stable values are needed (e.g. for accuracy transducers), the ALMEMO
®
D7 measurement plug measures with reduced sampling rate, if the setting
High Resolution is selected.
• The digital ALMEMO
®
D7 measurement plug comes with an integrated A/D converter. The measuring rate is solely determined by the A/D converter. All D7 measurement plugs run in parallel on the ALMEMO
®
V7 measuring instrument with their own measuring rate. The minimal scanning cycle of the measuring instrument is determined by the measuring rates of the D7 measurement plugs and is virtually independent from the number of plugs.
• The overall accuracy of the measurement is independent from the ALMEMO
®
V7 display device / data logger and form the extension cable used. The complete measuring chain, consisting of sensor and connected ALMEMO
®
D7 measurement plug, is calibrated.
• The measured values can be complemented with a unit featuring up to 6 characters. To designate a sensor it is possible to program comments with up to 20 characters. The user can easily perform the confi guration via the
ALMEMO
®
V7 measuring instrument.
Important! ALMEMO
®
D7 measurement plugs can only be connected to ALMEMO
®
measuring instruments of the V7 generation, i.a. ALMEMO
®
500, ALMEMO
®
710, ALMEMO
®
809, ALMEMO
®
202.
01.08
ALMEMO
®
Measuring Instruments
Measuring ranges, ALMEMO
®
2450, 2490, 2470, 2590A series
Sensor type / Measuring range
ALMEMO
®
series
Precision class
Type
2450
C
2490
B
2470
A
Temperature
Thermocouple sensor
NiCr-Ni Typ K (NiCr)
NiCroSil-NiSil Typ N (NiSi)
Fe-CuNi Typ L/J (FeCo/IrCo)
Cu-CuNi Typ U/T (CuCo/CoCo)
PtRh10-Pt Typ S (Pt10)
PtRh13-Pt Typ R (Pt13)
PtRh30-PtRh6 Typ B (EL18)
AuFe-Cr (AuFe)
Resistance temperature detectors
Pt100/1000 (P104, P204)
Ni100/1000 (N104)
NTC Typ N (NTC)
Heat flow
Atmospheric humidity
Capacitive with NTC
Digital temperature / humidity sensor
Digital temperature / humidity sensor
Psychrometric with NTC
Psychrometric with Pt100 (2 plugs)
Digital psychrometer
Dew point
Digital dewpoint sensor
Dew detector
Moisture in materials
FTA xxx
FPA xxx
FNA xxx
FQA xxx, FQADxx
FHA 646 xxx
FHAD 46x
FHAD 36 Rx
FNA 846
FPA 8363
FNAD46, FNAD463
FH A646 DTC1
FHA 9461
Water detection probe FHA 936 WD
Sensor for measuring moisture in materials FHA 696 MF
Moisture probe for wood FHA 636 MFx, FHA 696 MFS1
Material moisture sensor for granulates FHA 696 GF1
Moisture in the soil
Air flow
FDA 602 TM
Rotating vanes for air
Differential pressure for Pitot tube
Thermo-anemometer probe
Thermo-electric flow sensor
** Smoothing is possible for 1 measuring channel
Pressure
FVAD 15 Sxxx, FVAD 15 MA1
FDA 602 S1K, FDA 602 S6K
FVAD 35 THxx
FVA 605 TAxx
7
*
Range
7
*
7
*
7
7
7
7
*
*
*
*
* An average value channel is not possible with flow measurement; (no start of continuous or cyclic measuring)
Pressure transducer for liquid and gaseous media FDA 602 Lxx
Temp.-compensated pressure transducer FD 8214
Differential transmitter
Digital pressure sensor
FDA 602 D
FDAD 33, FDAD 35M
Pressure transducer, for wall mounting FD 8612 DPS / APS / DPT
Barometric pressure
Barometric pressure, digital
Plug-in probe for differential pressure
Force
FDA 612 SA
FDAD 12 SA
FDA6 12 SR, FDA 602 SxK
7
7
7
7
7
Range
7
Range
7
7
7
7
7
7
7
7
Push / pull force FKA xxx
* Only temporary zero-setting is possible; (no final value adjustment)
Tachometer
FUA 9192 Tachometer
7
*
7
7
*
7
7
7
7
7
7
Range
Range
Range
Range
Range
7
7
7
7
7
Range
Range
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7 7
7
7
7
7
7 7
Function Function
Function Function
7 7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7 7
Function Function
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
**
**
**
**
7
*
7
7
7
7
7
7
7
7
2590A
A
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
01.09
ALMEMO
®
Measuring Instruments
Measuring ranges, ALMEMO
®
2450, 2490, 2470, 2590A series
Sensor type / Measuring range
ALMEMO
®
series
Precision class
Type
Displacement
Displacement transducer, potentiometric FWA xxx T
Displacement gauge, potentiometric
Flow
FWA xxx TR
* Only temporary zero-setting is possible; (no final value adjustment)
Axial turbine flowmeter for liquids
Flow sensor with temperature
Electrical variables
FVA 915 VTHxxx
FVA 645 GVx
Split-core-type transformer for AC current FEA 6042, FEA 604 MN,
ALMEMO
®
measuring modules for
FEA 6044 N
DC voltage, DC
AC voltage, AC
Meteorology
ZA 9900 ABx, ZA 9901 ABx,
ZA 9903 ABx, ZA 9904 ABx
Meteo Multi (2 plugs)
Wind velocity sensor
Wind direction sensor
Rainfall and precipitation sensor
Rainfall detector
Radiation probe head
Star pyranometer
* for ALMEMO
®
2470-2 - function missing
Indoor climate and air conditioning
Globe thermometer
Optical radiation
Radiation sensor
Radiation sensor
Radiation sensor
Digital color temperature sensor
Water analysis pH One-Bar Measuring Chain
Redox-One-Bar Measuring Chain
Conductivity probe
Oxygen sensor
Gas concentrations in air
FMA 510, FMA 510H
FVA 615-2
FVA 614
FRA 916, FRA 916 H
FRA 616 D
FLA 613 x
FLA 628 S
FPA 805 GTS
FLA 603 x
FLA 613 x
FLA 623 x
FLAD 23 CCTx
FY 96 PH x
FY 96 RXEK
FYA 641 LF xxx
FYA 640 O2
Digital carbon dioxide sensor, hand-held FYAD 00 CO2
Carbon dioxide probe
Carbon monoxide probe
Oxygen probe
Ozone measuring transducer
Gas probes
Infra-red temperature measurement
FYA 600 CO2
FYA 600 CO
FYA 600 O2
FYA 600 O3
FYA 600 Ax
ALMEMO
®
infra-red probe head
Infra-red probe
Hand-held IR device
Digital IR sensor
* Emissivity cannot be modified
FIA 844
MR 7838, MR 7842
MR 781420 SB
FIAD 43
2450
C
7
*
7
*
7
7
7
7
7
7
*
Range
7
7
7
7
Adjustment
Adjustment
Range
Adjustment
7
Range
7
Adjustment
7
7
2490
B
7
*
7
*
7
7
7
7
7
7
7
7
7
7
Function
7
7
7
7 7
Function Function
7
7
7
7
7
7
7
7
7
7
*
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
2470
A
7
*
7
*
7
7
7
7
7
7
7
7
7
7
*
7
7
7
7
7
7
7
7
7
7
7
7
7
7
*
7
7
7
7
7
7
7
7
2590A
A
7
7
7
7
7
7
7
7
Prerequisites missing for perfect functioning
- Range: Measuring range missing or restricted -> Measured value cannot be shown.
- Function: Function missing for showing sensor-specific measured data (e.g. average value / cycle) or for necessary programming
- Adjustment: Measured value adjustment of this sensor is not possible (pressure, force, displacement, O2, pH, conductivity)
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
01.10
ALMEMO
®
Measuring Instruments
ALMEMO
®
measuring instruments, overview
Measuring inputs Expansions Display Graphics display D ata logger function
Integrated memory Interface / outputs Precision class Measuring rate (mops) max. Catalog page
Compact measuring instrument
ALMEMO
®
2450-1
ALMEMO
®
2450-1L
Basic measuring instrument
ALMEMO
ALMEMO
ALMEMO
ALMEMO
®
®
®
®
2490-1
2490-2
2490-1L
2490-2L
Professional measuring instrument
ALMEMO
®
2470-1S/-1SRH 1
ALMEMO
®
2470-2S
ALMEMO
®
2470-2
2
2
1
2
1
2
1
1
ALMEMO
®
2590-2A
ALMEMO
®
2590-4AS
ALMEMO
®
202 V7
2
4
2
Precision measuring instrument
ALMEMO
®
2690-8A
ALMEMO
®
2890-9
ALMEMO
®
710 V7
ALMEMO
®
8590-9
ALMEMO
®
8690-9A
ALMEMO
®
809 V7
ALMEMO
®
5690-1M09
ALMEMO
®
5690-2M09
ALMEMO
®
5790-2M09
ALMEMO
ALMEMO
ALMEMO
ALMEMO
ALMEMO
®
®
®
®
®
5690-1CPU
5690-2CPU
5790-2CPU
500 CPU V7
4390-2
Compact device (transmitter)
ALMEMO
®
2450-1R02
Basic device (transmitter)
ALMEMO
®
2490-1R02
ALMEMO
®
2490-2R02
Reference measuring instrument
ALMEMO
®
1020-2 X6
ALMEMO
®
1030-2 X6
ALMEMO
®
1036-2 X6
ALMEMO
®
8036 X6
4
4
4
4
4
4
4
C 2.5 35
C 2.5 35
4 4
4
4
A 10 65
4
4 4
4
4
A 10 65
4
4
4
4
4
4
4
4
5
9
10
9
9
9
4 4
4
4
AA 100 66 opt. 4
4 4
4
4
AA 100 66 opt. 4
01.24
01.26
4 4
4
4
AA 2000 66 opt. 4
4
4
4
opt. 4 AA 100 66 opt.
opt. 4 AA 100 66 opt.
4
4
AA 2000 66 opt.
4
4
4
01.28
01.33
01.33
01.31
9 opt.
4
opt. 4 AA 100 66 opt.
4
01.38
9 opt.
4 4
4
4
AA 100 66 opt.
4
01.38
9 opt.
4 4
opt. 4 AA 100 66 opt.
4
01.38
opt.
4
4
4
AA 100 66 opt.
4
01.48
opt.
4 4
4
4
AA 100 66 opt.
4
01.48
opt.
4 4
4
4
AA 100 66 opt.
4
01.48
20 opt.
4 4
4
4
AA 4000 66 opt.
4
4 01.35
1
4 4
4
4
AA 100 66
4
01.58
1
1
2
2
2
2
9
4
4
4
4
4
4
4
4
4
4
B 10 65
4
4
B 10 65
4
4
A 10 65
4
4
4
4
4
4
4
4
4
4
4
B 10 65
B 10 65
A 10 65
A 10 65
1000
C 2.5 35
B 10 65
B 10 65
AS 1.25 4
AS 1.25 1
AS 1.25 7 opt. 4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
01.14
01.14
01.16
01.16
01.16
01.16
01.18
01.18
01.18
01.21
01.21
01.12
01.50
01.56
01.56
01.60
01.63
01.65
4 4
AS 1.25 7
4 4
01.67
01.11